Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
066-120-004
.�.. •_ +'i . _4_-. f J. w` -ori:- - . 1 T"' _ _ _ _ _ -:ice r-.�. .•--"--- '^pro . •� �..._�...,.-ice - .. �. _ - )��•^��.. SCOTT UPTON 66-12-04 LEureka Dr, Magalia .CohtR: Robert Davis f Permit#3481-88B,P,E,M(new single family t 0 �Q L� 4 . 3481-88B,P,E,M PERMIT NO. '" PERMIT EXPIRES OWNER SCOTT UPTON C6NTR. Robert Davis Const 3-D ASSESSOR PARCEL 66-12-04 • Eureka Dr, Magalia LOCATION f� 4: OFFICE COPY r Address 37Z rGan/Z�E'/Li .— V`� rz n�i'a 2� G F C t• GAS y. Date'_ Meter By _ e r`, ELECTRIC Meter By n••x! Dater=1i OFFICE COPY I 13-7 j. Address GAS Meter By �i �'S Date 1� 1s, ELECTRIC �r i Meter By Date Temp. Power Pole Called PG&E Temp. Elec. Service Called PG&E 1 J = OK 0 = Not OK Readyiable MOBILE HOMES ° ''> ; MISCELLANEOUS Date MOBILE HOME UTILITIES (Plans) OK except #'s Date DECKS,COVERS,CARPORTS,GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 1. Zoning Requirements -Setbacks -Easements +j 2. Soils; Special MH Support -Sketch 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Sewer; Location -Test -Fall -C/O -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4. Wood Awn.; Posts- Beam s-Rftrs.-Connec.- Shthg.-Rfg.-Bracing 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 6. Gas; Location -Test -Wrap: / P'U ft. / /"Nat. or/ /"L"ft./ P'LPG 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Utility Clearance 7. Elec. 8. Frmg; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh Card -B1 Date Card -131 Date 10. Roof; Shthg-Roofing Card -131 Date Card -61 Date 11. Ext.; Steps -Doors -Landings Date MOBILEHOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements Card -61 Date Card -131 Date 2. Footings; Size -Spacing -Marriage Line Card -B1 Date Card -B1 Date 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances Date POOLS (Plans) OK except #'s 5. Drain; MH Test -Fall -Flex Connector 1. Setbacks -Easements 6. Water; MH Test -Regulator -Connector 2. Soils; Compaction -Structure Stability 7. Water and Sewer Connected -C/O to Grade -HD Approval 3. Pool Structure; Steel -Connections -Thickness - Dead Men -Lining 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 4. Elec.; Receptacles and Lighting, Distances-GFI 10. Cert. of Occupancy 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.;Grounding; Equip. w/5' -circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main in Conduit Card -B1 Date Card -B1 Date Card -131 Date Card -B1 Date 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Card -131 Date Card -131 Date Card -B1 Date Card -131 Date • l \ v = OK 0 = Not - =Not Applicable RESIDENTIAL (Single and Duplex) = Not Ready Date UN ERFLOOR (Plans) OK except #'s Zon ing-Setbacks;-Easements-Flood -Slope , Main; Soils-Steel-Elec. Grnd.-/ (Z/" qlot tg., Garage; Soils -Steel-/ ft, /" Ftg. Dept 4. Ftg., Porches & Decks; Soils -Steel-/ P, ,- remwalls, Main; Steel-Blockouts-Wrappe "emwalls, Garage; Steel- Blockouts-Wrap 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel D.W.V.; Fall -Fittings -Test -2 way C/O -Sewer Test 10. Gas Pipe; Size -Anchors Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric; Underground ],?."Plenums & Ducts; Clearance-Material-Supprt-Ins. Sills -Anchor Bolts -Joists -Vents n 15. Insulation Card -81 G G Date 17 S $$ Card -B1 any Date � Card -81 <Q-> Date\ -k -7,M Card -131 Date Date PLUMBING (Permit) OK except #'s 16r.'Water Ht. Vent -Access -Combustion Air -Baffle ater Pipe; Test & Anchors -Nail Protection t6.-V.W.V.; Test-Fttngs & Anchors -Nail Protection 19. Shower Pan; Test, First Floor -Tub Access 20. Test Tub & Shower, 2nd Floor -Tub Access *V1. Gas Pipe; Size & Anchors Card -131 [�G Date 3-Z8:9 Card -131 Date Card -B1 Date Card -81 Date Date ELECTRICAL (Permit) OK except #'s 22. Fixture & Transformer Clea ce-Ins. Protection IM-Elec. Receptacle ing Lights & Switches at Doors e Boxes & No. of Conductors 26<Romex Installed Close to Edge of Studs & C.J. 0'. Equip. Ground made up w/Meeh. Fasteners n & Water 7. 2 Appliance Circuts in Kitchen & Conductor Size/G.F.I. 28'Subfeed Wire Size A / ga. Cu ot!! A.C. Wire Size / /ga. Cu or Al Range Circ. / Q / ga. C) or AI -Oven Circ. / / ga. Cu or Al. Insulated Neutral lfg> No 410-S'ervice-Riser Conductors & Ground -Main Disconnect 34Eituip. Clearances Panels-Motors-Mech. Equip. 32 -Clothes Closet Light -Shower Light -Spa Light 33 -Smoke Detector Card -B1 rG Date3-e8,8 Card -B1 Date Card -131 CSG Date 1,30.601 Card -B1 Date Date MECHANICAL (Permit) OK except #'s 34!A.C. Ducts Insulation & Support 30 -Vent Fan; Exhaust above insulation 36. Condensate Drain & Overflow; Size & Grade 37. Furnace -Vent; Access -Comb. Air -Return Air Vent -115 outlet 38. Attic Access & Platform if Furnace in Attic Card -61 :6 f; Date3-28,%4Jj Card -B1 Date Card -131 Date Card -81 Date Date FRAMING (Plans) OK except #'s 3(r Sills, Proper Material & Anchors 46.'Walls Studs -Nailing, Spacing & Bracing—Plates-Sound 4,1 -Bearing Walls over Girders & Floor Nailing 48" Draft Stop in Walls (rat proof) 02&te Stops; FurLa&Ceilings-Sts rs-Chases-Tub Header &4MAnl-Size 8T6e: ffTM Date FRAMING (Continued) 45. Hangers -Post Caps -Anchors -Connectors dV"ClIng. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfng. fireplace Ties or Type A Flue -Fireplace Throat Clearance 4&. -Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 49-Rdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions arage Fire Protection Framing 51 --Property Line Firewall & Openings Sq -Ext. Doors -One T -Check Garage -3rd story, 2 exits 58 -Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection lywood on Roof Overhang -Attic Vents -Rafter Outriggers Siding -Nailing Veneer 56. etomo Mesh -Drip Screed -Fd. Vents-Underflr. Access 57 GTazing Area -Glass Protection -Skylights -Plastic 58. Shear Walls; Nailing -Bolts su�tion- s -CIS 60,oKfiltration-W rs - Wntrws Card -B1 (' Date3.?A_ffi Card -B1 (gQ Date 3.3o,8q Card -B1 Date3,ZJ<'VJirCard-B1 Date Date FI(Plans) OK except #'s N O.T. xt. Steps -Door & Sidelight Protection -Landings 6� , oke Detector .Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor -Ducts -Meeh. Protection 64!Bedroom Exiting F.I. & Bath Fixtures & Tub Access -Spa IN-1Eec. Trim & Subpanel; Breaker Sizes -Labels Stairs & Rails fireplace or Stove; Clearances -Hearth 69-E .outlets at Wood Panel; Int. & Ext. . i . Fixt. & Appliance; Grnd. -Air Gap -Cooking Clearance lec. Outlets & Receptacles at Kit. Counter 6VrGarage Fire Door; Swing -Landing -Closer Duct in Garage -Damper tr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor -Meeh. Protection �Ip., Elec. & Mech. Equip. Listed for Location 7�Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. Insulation -Foam -Looked in Attic ❑ Yes 76-aUard Rails & Deck Construction -Post Caps dn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes Following instld.; Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑ Yes ❑ No J31. , Brown -Finish A.C. Unit; Disconnect, Electrical, Plumbing ents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Openings. ater Well; Disconnect, Electrical, Plumbing Exterior Elec. Trim; G.F.I. Receptacle -Underground 8 tilation throughout House 87, lass Protection Correctio from Previous Inpections CSG 5 �i Gas -Meters Tagged; Gas -Electric U-{,,, ?I ft p„ luy W. ter & Sewer Connected -C/O to Grade -HD Approval Energy Compliance Certificate -Other Certificates 92. Roofing Certificate Card -131 !&G Date t_z5_8q Card-B1&G . Date!5�_(S-8,q. Card -81 Date . j:Bfx Card -131 `" Date Card -B1 Date itAZ,$0)Card-B1 Date Comments at Final: (NOTE: An entry must be made each time you visit job site) COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS ` _ i 196 Memorial Way, Chico — Phone:.891-2751 7 County Center Drive, Oroville — Phone: 538-7541 747 Elliott Road, Paradise— Phone: 872-6307 CORRECTION NOTICE OWNER ` PERMIT NO. ' A routine inspection indicates that the following violations of County Ordinance exist'at the above address and should be corrected. Please notify this office t when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office Immediately. �kLrhwl G12T. `boz�2 Inspector �tLL--� Date COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way. Chico - Phone: 891-2751 7 County Center Drive. Oroviile - Phone: 538-7541 747 Elliott Road. Paradise- Phone: 872.8307 CORRECTION NOTICE 3q OWNER PERMIT NO. A routine Inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. -Please notify this office when correction of work is completed. If you have any question pertaining to this 1matter, or need additional explanation. please contact this office Immediately. �! S0L\Ih V-)L0CI& L' 12tlt,s I.rSS T 4 A j t eG 2 t -ii- 20 M7`7X Do N1 OT G'fza" P PjNL L MAX- 1& 0 e, _� StA Pioa-r 1A-1)bRR" b(&bM V( t-, W'n)'�,6w �-KiT/c1C. RMS, FUcxSkA LT. '?A j T- < (t k c 0 %A -m n Ir45^kAl.Artizaf %%kA►/J'I> T(,6�% S1Ad_ 11Ne,QJG l a-9(1 i-rz -JN k -L Dt�t �c_�,n�e,IAt(-, 'fq - Q0^11\ AAs 9I i�i�G At'T6/t 7�✓Sr(� «cp�/�✓ �Wy Inspector 117;d .r -v-, Date -3-28 -B,5 COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS .. y "196 Memorial Way, Chico — Phone: 891-27,51 7 County Center Drive, OroviIle— Phone: 538-7541 y' 747 Elliott Road, Paradise — Phone: 872-6307 CORRECTION NOTICE c,lPTo�( 3461 -88 OWNER PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this. office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. ' LocIL 2%tr t2 SO \NTS, ' wcV_ CQkM'f_s LI.SS rON 141. Inspector � A LL_"�' Date —.---- --- _..._...� _.r. ---- l' a r: m l.1: I•lu . _ .. _ _ ..._.... - '1' J F ICA '1' _J6LOCATION tJ ti ., p/.�%%% ����/ --- ,.Q Cit Gt-� •, A. P. No. UESCR1171.0I4 OF INSl.i1.,A'TION t ROOP Material. _ Brnncl Name_ ° Th ickttess(inchen)_ — _ 1'hetlnnl Rcnl.atnnce (R Vnl.ue) EXTER1.011 WALL tfaterial F ibc.rg l-asss llrnud Nnme Cerl-ain'Feed ' Tit ickttens(ittches)� �a" '1'Itennnl. Reaiatnnce(R Value) /3 CEILING Bntt or Rlnni(ct Tyne Fiberglass llrnud Nnme Certain7'eed Thickttegs(inches) — /p Thermal ltesistnnce(It Value) �p Loose F.LII Type—.1?lbe.r-c J -ass llrand Name C rl-ain'Feed Itininu.nn 'l'Iticknesp(Tncites) //" Plumber of ]M,g Arca +.ovcrcd(ft 7 02� Wt. per b FLOOR, El �.. �i •.. UC:%�. D Ila ter.lnl_ l.j.bot lass Brnnd Nnme Certa:i.n'Peed 1'hi.ck to ns(i.ncltes)7 4e FLUOR, S!,AI) The (teniatnnce(it Vnlue) /9 Ila tcrl.a l Brawl Nnme I'It)r.knrtnS(i.nclie s)�—~� — 1'hr..r7n,.t1 Itesi.atrutce(it Vn].ttc) — Widtlt(Lncltn.$) FUI]NUA C ION WALL --- 1Ltl.crlal. llrnud 1'hiclv.tcrts(inr_ltes) -- 7:hermnl Itcaistnace(ll VttLne)� l hereby crrt.i.fy l:bat the nbvv(e 1_11g1l:t ttoll waS i.ttSl'Jtllec.l i.tt 1:11n. above bulAdinR I in conformance with I:lte St:tte of Cni.ifortiin FtterCy Requirementa, Hawkins I:rt,,tr.l a Liort 379407, , — F I RI•I r,Intn-/rna�ir•.rt — --•--- - —..w.:� - — _ ,� r S'1:A:FE (;OI''1� 1C'TUR�S l.IC,Iarsr NU. V S .ran.cul i; ttl'-7.[i8'lA1,l A'1'l61 nt�fi,.1.c:AI Uit�" )All: 1 ltereb 1 ni,ovc i.nnulation awl nll required items ni nhowit on the + 1{ui.ldini; lleprtrtmcut npl,rovecl platin ntid nttnclnnenta hnve been inot-alled ns rc�iuircd I,y the State of Califurnin I uergy Requirentents. All egttil,ntettt, dev.i.cc�S and• uutecri.nIn nre ()1` the quality prencribed or or(! npecificnl.ly npproved by the Statr. of Callforttin. 30 � F1.I_q S trm U[ tJMli•;/OIJNIIt (!'lenge i — — — _ 1 ) STATE COUIRACTOR'S LICENSE tIU; S1(,Nr1'1'UR!d OF lali,tJI:RAI, ^CUtr.l'ItAC'l'UIIJ?UlJ1Ji;It —KZL22�� DATE TIIIS (J-10 lF1CATE, 111IS'1' BE UIJ F:LLE WITH '1.'111: 131-11.LDINu DE'VAR'TNENT Plum TU. uIIAL I1-ISfEC'1'1ON APPROVAL ADD A COi'li SIIAI,L• Ill's POSTED WITHIN '1'1113 IIUILULNG .t:u►uary loll/r • COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, Califorriia 45965 - Telephone: 916/538-7541 APPLICATION AND PERMIT 4 E1 / N0._ l ASSESSOR PARCEL NU B _— p I BUILDING PERMIT OWNERU T LEP ONE ,SO. FT. OCC. UILDIN V LUATION OWNER'S MAI INGA DRESS s � Du cL CONTR TO 'S A- E , `_� TELEPHQN CONT ACTO 'S MAI NG ADDRESS P. Fireplace CONSTRUCTION R 4mlA ax UNKNOWN Total Valuation Is Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ - Energy Plan Checking Fee $ {J'){ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty BUILDING ADDRESS 2 Permit fee `$ $ PLUMBING PERMIT Filing Fee 10.00' Each Trap 2.00 Solar or heat pump water heater 20.00 LOT N SUBDIVISION N! PARCEL MAP 3 S Water piping 5.00 Each gas water heater or vent 5.00 Q USE OF STRUCTURE SF�uplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G I W 0.00ea TYPE OF WORK New Q --*'Addition ❑ Remodel ❑ Utilities ❑ installation Other ❑ Describe work: ., ,A 1An Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service SOOV OR LESS 100 AMP OR LESS 10.00 o. Od Main service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check One): I am licensed under provisions of Chapt. 9, Div. 3 of the Business/POWER and Professions Code and my license is in full force and effect. License No. y CISE Classification B El 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. ( DWELLING OCCUP. OR ACDNS. l ACC. BLDGS. y2¢sgft NEW CONSTR.ULTI.OUTLET NON.RESIO BRANCH CIRC 5 2.50 Be APPARATUS e) (SINGLE OUTLET CIR. Ex. Occu pOUTLETS OR FIXTURES 30 SALOewL030 FIXED Ex. Occup. OUTLETS P(RESID,)LISIS REA.) 2.00 Temporary service 10.00 ..► Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ 1 have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ® I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you,must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating . oo Cooling Hood 3.00 Ventilation pernl4 Fee $ _ (f Contractor . I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot_ Butte to enter upon the above-mentioned property for inspection purposes. ainst allso liabilitieree s, judgments, costs,nandeexpen eless the s which may in anof y wayutte aaccrue against said County in consequence of the granting of this permit. X /U2 D�y� Date�O%J.SArThis Signature of Applicant - Owner ❑ Contractor R Agent ❑ An OSHA permit is required for excavations over 5'0" eep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ TOTAL PERMIT FEE $ OCCUP.] \�J C°NST.TrPE SCHOOL FU:TA PD NG s3 E permit is hereby issued under sions of the Butte County Code and/or work. indicated above for which EC UBLIC By PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date / �Z' 000 Receipt No. -go - WHITE-D.P.W-. YELLOW-ASSES30R. PINK -INSPECTOR. aOLVENROD-APPLICANT . _" _.$;.4ruj, ..._,.+^.. "` . +art. - ,3.-L,,.-.., y... -' ,: j)v. _.3�f.:.^^ ,-.- `ri.-..+ ^' :: ',.`." J %' tti( '+'t-R•1/y,�r� COUNTY OF BUTTE - DEPARTMENT OFfPUBLIC WORKS - BUILDING DIVISION , 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE: 916/538-7541 PERMIT APPLICATION DATA SHEET Permit No. OWNERA. P. No. - Proposed Building Use Building Inspector �S Date /L � At time of permit application, I was advised the following data must be submitted prior to permit processing and:/or issuance: DATE RECEIVED APPROVED 1. All items.have been submitted. . . . . . . . . . . 2. Plot plans in duplicate./triplicate, signed by preparer of plans. . 3. Complete plans in duplicate./triplicate, signed by preparer of plans. 4. Complete engineered plans and calcs, with wet signature on plans. 5. Plans with Energy Design Compliance Statement. . . . . . U --S School District "Fees Paid" Stamp on Floor Plan. 7 Statement of Intent fo�r/No Heated and AC Buildings. J Fees of $a7` .. 9. Letter of signature author izati n. ESanitation approval from � 0-/ Health Dept. • . . 11. Planning approval for (A) Use: (B) Parking: . 12. Certificate of Workmen's Compensation Insurance. . . . . . 13. Contractor's License Information (no., name style, classif.) 14. Owner -Builder Verification (Given to owner❑, Mail to owner ❑ ) _15. Improvements may be required. . . . . . . . . . . . 16 Mobi lehome Installation Data • Pre-Inspec. request to (Date) 17. Pre -Inspection for Required. Building Inspecto 8' %�/ Recorded copy of Agricultural Acknowledgment Statement. d0 19 Driveway Permit. 20. Plot plan approval from city of 21. Engineered trusses in duplicate (required prior to plan check). r ..J 22. /, I, - 1 I3 When you issue the ermit, process as follows: 1 Mail �elephone�//a �� and hold"for pickup a Other Applicant ner,, Doff i t1 —Mail to contractor. r7� Deliver w/inspector. i ;,✓ - , ,vim, Copy of plans sentli Health Dept., Fire Dept., Other , ,/ i_l Date The following data must be submitted prior to permit issuanc ircle new itemfnot checked above). 1. Index permit for above items No. 2. Additional itemsfreq{uired: I 1 t Contractor, designer, owner, was advised of above required data by_phone_lnall_counter by date Contractor, designer, owner, was advised of above required data by—phone —mal l—counter by date Plans checked by OW?Dpe Plans approved by Date _ Sets of plans on hold in r 41 Copy—DPW File cabinet AP folder i $`TO.: Building Department r FROM: Environmental Health a i 1 SUBJECT: SA ITATION LEARANCE OWNER 'Plans approved for: Hold final for: Final Clearance�JO.K. for: Clearance for J bedroom Clearance for addition of Not I TARI AN Sewage Disposal LO CATI N /A=fir 14�ir Water Supply Water Supply Water Supply DATE 200 4-11 i .—._ 1 � ±- } r i :- t � L}-•� 1_a L I.. , r' I ! •` I{ r' I I I I+ 1 � ..L.i r' r r r 1 I'7r1 ! 7 , 1 _{ , t�t- {1..{.-t 1801- 160' 80' 160' IT 140' �- _ _ I_,.,__._ t:_, .-:.••-/S•b 1• ,- -t� - of 120' - .. .__ r-� .. ... _ .,, r r .' _ •.off. �' }..:.. .\ / - - - / i - — ti , k 100' I i �... _, r. r j I• f -i . !_ j r .i_ ,..r r , 1 , ii�'i;t�a- 1 . t r •, �, 1 r I I 1 1 , j , � 40' — 1 t i L 40 ' _ �__i 60 , , 8t,_, , i i Li X100' - �_ 120' - 140' 160` TO: Building Department FROM: Encroachment Permit Section RE: Driveway Clearance E7rr�e�� %Z- �!f �p/�Pd �Cc dg's AP # owner location X70 has been issued for the above property. Driveway permit , date si ature urn to DPW AGRICULTURAL STATEMLNT_OF ACKNOWLEDGEMLNT FOR RESTDENTLAL D1 VI LOPMENT ScIcti.on 26-8.1 of the Butte County Code r quires this acknowledgement be recorded 1)Tor to .issuance of a building per e property described herein is adjacent "1�c ro. land or included within an area zoned fo agricultural purposes, and residents ACCEPTED FOR R��i� of this property may be subject to .incon-? Ai 8.01 A. M, - y veniences or discomfort arising from the usIe of agricultural chemicals, i_ncl.ud.ing, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit od agricultural operations including, bust nOL limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established ;i,;ricul to a.l zones which have as a priority use for productive agr:icul.Lural purposes, ;ind w ithin sa i.d zones and on adjacent property should be prepared to ;Iccept such i nc ()rvc•ii i ens o or disconform .from normal, necessary farm operations. A11 that real property situate in the County of Butte, State of Ca:Li f orn i;t , dc•tic r i hc•c1 Follows: M l KARM MELVEY n NOTARY r'uBLIC-CALIFORNIA durte ,:OuntY j My Coma LWOn Erprres reb. 23,1 gd0 T, ca j I�"®FSS®»®®®®�®®Eli36'9�®�®S)Ffdti7(' St.bte of Calif. ) SS. ('uPnty of Butte ) V ca On this the 8th day of ivovemDer 9 1y the undersigned Notary Public, personally appeared Scott A. Upton and Debbie R. Upton uu , bel o re 111u, Personal- ly known to me. ©XProved to me on the b;isiti LKA HELVEY of satisfactory ev.idencc. t Nr'U[3UC-CALIFORNIfyCci'be the persons) whose names)dutte.:�wnY /u1jscribed to the within instrument and acknowledged Lh;rlionExVlr �b 23,1eX@cuted the same for the purposes therein contained . I N WITN'l tiS wasonsomemramOmOm"OMEOF, I hereunto set my hand and olfic:ia.1 seal. esent A.P. No. N o L a r y P.lalfl�i-r-= AD ORDER NO. BU -100256-2 DH DESCRIPTION ALL THAT CERTAIN' REAL PROPERTY SITUATE IN THE STATE OF CALIFORNIA, COUNTY OF BUTTE, DESCRIBED AS FOLLOWS: i PARCEL I.• LOT 4, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "PARADISE PINES COUNTRY CLUB ESTATES UNIT 211,' WHICH -MAP WAS RECORDED' IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE,. STATE OF CALIFORNIA, ON OCTOBE 13, 1971, IN BOOK 38 OF MAPS, AT PAGE(S) 61, 62 AND 63. i EXCEPTING THEREFROM APL MINERIIIS, OIL, GAS, ASPHALTUM AND OTHER HYDROCARBON SUBSTANCES, WITH PROVISION THAT ANY AND ALL MINING OPERATIONS SHALL BE DONE FROM ORIFICES OUTSIDE THE SURFACE AREA OF THE LAND DESCRIBED HEREIN, AND THAT NO DAMAGE SHALL BE DONE TO SURFACE OF SAID LAND. PARCEL II: A NON-EXCLUSIVE EASEMENT OVER LOTS A, B, C, AND E, (THE COMMON AREA) OF SAID PARADISE PINES COUNTRY CLUB ESTATES UNIT 2 AND THE LATS DESIGNATED FOR gOMMON AND RECREATION AREAS AS DESCRIBED IN THE DECLARATION OF ANNEXATION FOR UNITS IV, VI, VIII, X, XI, XII., XIII, XIV, XV AND COUNTRY CLUB ESTATES UNITS 1 AND 2. It h PAGE 5 C�r '1��4WAv4wk . . f a BUTTE COUNTY SCHOOLS DEVFL•OPMENT FEE'CERTIFICATION FORM <a (One Form per Building) A.P. Number �p�p-� ar-Q Building Department No. ' School District City Q County Jurisdiction Property Owner Project Location/Address ` /,Z�/%��Gi. �l /r i'D/� �L w .•i._..: , h Subdivision s Lot Number Residential Development: ; Sq. Footage # of Living MHI Addition (Group R) Units Commercial/Industrial: Sq. Footage New Addition (Including Exterior ' Roofed Areas) Buildin Departmelt epresentative Date Dist ri -t Td No.. School District certifies that X77 X10 (Applicant Namd) Phone Number) ( Street Address) City) (State)/ (Zip Code) ` has complied with the requirements of Resolution No. ' by the payment of $ 2 �'T3,w9. representing , 5j� s uare feet. !� 8' e ��5' Schoo1Y District Representative Date PAID BY CHECK NO. REMARKS: r BANK NO go `�0(p PAID BY CASH white -applicant, yellow -building department, pink -school district SCHOOL . FEE (5/88) RESIDENTIAL PLAN CHECKING GUIDE 7/85 .(S.F., DUPLEX'&•MISC. ONLY) Bldg. Permit # 3'L/ OWNER (A �D�'o IJ A.P. # GENERAL 1✓.Zoning requirements: (sideyards and number of permitted living units). 2/ Valuation. 3;r Plans signed by designer. 4. Energy Design.and Compliance. 5&/ eExisting violations on property. PLOT PLAN 14#'0' Complete parcel size and dimensions. Setbacks, sideyards, easements, etc. Other buildings or structures. Grading, fills, drainage. 5/ Flood hazard. Special conditions on creation map or compliance document. FLOOR PLAN VOO'Complete to scale plan with dimensions. ao-4�equired windows for light and ventilation (Sec. 1205). 3)/ Required windows for second exit (Sec. 1204). adr-'97ylights (Chapter 34 & Sec. 5207). 5- uman impact glass (Sec. 5406). /Required room sizes, ceiling heights (Sec. 1207). *0 .F.C.I.'s in baths, garage and`exterior outlets (Article 210-8). Light fixtures, switches, receptacles, and exterior receptacles for maintenance of mechanical equipment. 9k- ocations of water heater, heating and cooling equipment, other electrical or gas /equipment, and plumbing fixtures. 1'. Garage firewall, door size, and closer (Sec. 503(d)(3)). 1� 3'0".exterior exit door (Sec. 3304(e)).— 1!/Fireplace-and wood stove location. 1Z Smoke detectors (Sec. 1210). STRUCTURAL DETAILS 1. Foundation plan complete enough -:to construct building. 2. Floor construction details complete enough:to construct building. 3. .Elevations and wall construction details complete enough to construct building. 4. Roof construction details complete enough to construct building. 5. Fireplace construction details and calcs if necessary. 6. Sufficient data and details to satisfy energy requirements (State Law) (Form 1). MISCELLANEOUS ITEMS TO LOOK OUT FOR 2/xposure I plywood on exposed locations and overhangs. 2(/ Stairway details: landings, rise and run, head clearance, handrails (Sec. 3306). ,-3-.---Guardrail details (Sec. 1711 & 3306(j)). wick or stone veneer (Chapter 30). e for plaster --weep screeds (Sec. 4706). roper roof pitch for roof covering (Chapter 32). Le/ Rafter ties or bearing ridge beam. 4 RESIDENTIAL PIAN CHECKING GUIDE MISCtLLANEOUS ITEMS TO LOOK OUT FOR (CONT'D) Garage door or porch header sizes. Adequate bracing. (CONT'D) ming area over garage - complete -1 -hour separation required on garage side i luding supporting walls and posts, etc. wo exits on three-story dwellings (Sec. 3303 & see Mezannines 1716). 1 ,✓Attic access and ventilation (Sec. 3205). l�. Underfloor access and ventilation (Sec. 2516). 1:: Wood stoves, clearances, alcoves & 1 -hour shafts. i . Combustion air for fuel burning appliances. 'Noise requirements on duplexes. .14 ---Adobe soils - special foundation design. -tt'.'_Retaining walls requiring design. -r9t- -Unusual shape, size or split level house requiring lateral design. 3. I Qe� s��cs ek cul(eg�j A(lceol�' Y6 7/85 .Certificate of Compliance: Residential - . . Climate Zone 11 3y8/- Bat7dtng rawt Y Project Address T thor Checked By/ Date oF Enforoanent Agency Use only Glass Ar GE G1 BUILDING DATA -- Thickness - (slab/exposed, tile, etc.) - (SO North 97, S 6.4 ty 1�1 FE HVAC SYSTEMS Minimum _ Conditioned Floor Area f 3 Number of Stories Type (furnace, air Efficiency East Duct Output Manufacturer / Model # conditioner, heat pump) (SE, SEER,HSPF) Slab/Raised Floor �5�-. Number of .Units 076 Wim? 064 [ Bingle Family Detached (SFD) [ ] Addition Alone Maximum mum Furnace Heating Output: t- 33 2.12 HOT WATER SYSTEMS Tank Manufacturer/Model { [ ] Single Family Attached (SFA) , [ ] Existing Building equal) Special Feature(s) Skylight Total yhght D [ ] Multi -Family (MFS (] Existing -Plus -Addition . BUILDING SHELL INSULATION # Component Insulation . - Location/Comments Type R -Value (attic. to &arage, typical, etc.) . p BU i t E_r%"*#-LJ7VTy Wall .............. Roof ............. Bi1Fl.l�1 Roof .............AP Floor ............. O V .,. Floor........... Slab Edge..... . GLAZING-- _ Shading Devices - Glazing Area Glass Type Interior Exterior Overhang Framing Type Orientation _-- (st) (singlie. double) (yoller blind. etc.) (shadescreen, etc.) (yes/no) (metaUwood) , North ( ) Q7• r X41 ASA 4% 4./ North (-) East East South Sou th ( ) West ( )_ West - Skylight....... " U. THERMAL MASS Type/Covering - - Area -- Thickness - (slab/exposed, tile, etc.) - (SO (inches) Loeation/Desc"12tion (kitchenk bath, etc.) ty 1�1 FE HVAC SYSTEMS Minimum _ Duct - Type (furnace, air Efficiency Location Duct Output Manufacturer / Model # conditioner, heat pump) (SE, SEER,HSPF) (attic, etc.) R -Value (Btuh) (or approved equal) 076 we_ 064 7Maxi. r7- Maximum mum Furnace Heating Output: 2fi 1.71 Btuh - HOT WATER SYSTEMS Tank Manufacturer/Model # _ System Type (storage gas. etc.) Capacity (or approved equal) Special Feature(s) S was SPECIAL FEATURES/REMARKS (Add extra sheets if necessary) Mandatory Measures Checklist: Residential MF -111 NOTE: Lowrise residential buildings subject to the Standards must contain these mcasures regardless of the compliance approach used. Items marked with an asterisk (•) may be supirsebed by more stringent compliance requutments listed on the Ccrtifiwe of Compliance. When this checklist is incorporated into the permit documenm the features noted shall be considered by all parties as binding minimum component performance spearreationa for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPtiON urswnex tl�NRlrs+rl.l Building Envelope Measures 62.5352(a): Minimum ceiling insulation R. 19 weighted average. §2.5352(br Loose fill insulation manrufactunu•s labeled R -Value. §2.5352(c): Minimum wall insulation in framed walls R -I 1 weighted average (docs not apply to exterior mass walls). 6 2.5352(kr Slab edge insulation - water absorption rate no greater than 03%. wua vapor transmission rate no greater than 2.0 pemilinch. §2.3311: Insulation specified or installed mats California Energy Commission (CEC) quality standards. Indicate type and form. 62.5352(x): Vapor barriers mandatory in Climate Zones 14 and 16 only. - §2.5317: Infiltsation/Exrdtration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows wathersrripped. all joints and penetrations caulked and sealed §2.5352(e): Special infdtmdon barrier installed to comply with 12-5351 mats CEC quality r standards. §2-5352(dy Installation of Fucplaces I. Masonry and factory -built fireplaces have ' L Tight filling, closeable metal or glass door b. Outside air intake with damper and control . c. Flue damper and control 2. No continuous burning gas pilots allowed. HVAC and Plumbing System Measures §2-5352(8) and 2.5303: Space conditioning equipment siring: attach calculations. 12.5352(h) and 2.5315: Setback thermostat on all applicable heating systems. • §2-5316(a): Ducts constructed. installed and insulated per Chapter 10, 1976 UMC §2-5316(b): Exhaust systems have damper controls. §2.5314(c): Gas-fved space hating equipment his intermittent ignition devices. §2.5314: HVAC equipment, water heaters. showcnccads and faucets certified by U+e CEC. ,- • , • _ . _�_ • §2-5352(i): Water heater insulation blanket (R-12 or greater) orcombined interiode"tuior insulation (R-16 or greater): fust 5 feet of pipes closest to tank insulated (R-3 or great"). ; §2.5312(Excep6on 1): Pipe insulation on steam and steam condensate return & recirculating _ . .. piping. §2-5318(d): Swimming Pool Heating 1. System has: ) 9 a On/off switch on hater. t b. Weatherproof instruction plate on hater. e. Plumbed to allow for solar. ' 2. 75 percent thermal cfrtciency. ; 3. Pool cover. 4. Time clock. 5. Directional water inlet Lighting and Applianct Measures 12-5352(1): Lighting - 25 lumcns/watt or greater for general lighting in kitchens and bathrooms. ' §2.5314(c): Gas rurA appliances equipped with intermittent ignition devices. 12-5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. COMPLIANCE STATEMENT ; This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Chapter 2-53 and Title 20. Chapter 2. Subchapter 4. Article I of the California Administrative code. This certificate has been signed by the individual with overall design responsibility and the building owner. who shall retain a copy of it and transmit the certificate to my subsequent purchaser of the building. . Designer Building Owner Name: �1'$q" f%iri�'� Name: Tttlr/Fum Titkr-um- , Address: Address: Telephone Telephone t.ic. /: (signamm) (date) (signature) Documentation Author Name: TitklFum: Address: - Enforcement Agency Name: Agawy. Tekoxmc (date) 4f� 1. Ceiling Insulation 444 -70 -46 Number of stories -120 R -value One Two Three R-0 -103 49 32 R-19 -8 4 -2 R30 -2 -1 -1 R38 0 0 0 U -value 4 0.06 -6 0.50 -176 -84 -54 0.30 -102 49 -32 0.10 -26 -13 -8 0.08 -18 -9 -6.. 0.06 -11 -5 4 0.04 4 -2 -1 0.02 4 2 1 0.00 11 5 3 1 0.60 6 2. Wall Insulation 2 0.50 9 Single- Single - 0.40 12 Family Family Multa R -value Detached Attached Family R-0 -68 -51 - 34 R-11 0 0 0 R-13 2 2 1 - R-19 8 6 4 U -value W 22 37 -9 0.80 -153 -114 -76 0.50 -91 -68 -46 0.30 47 36 -24 0.10 0 0 0 0.08 4 3 2 0.06 9 7 5 0.04 14 11 7 0.02 19 -14 10 0.00 24 18 12 3. ibLwd Floor Insulation 12 • 16 r 0 4 Insulation in Floor , 17 Number of stories -17 R -value One Two • Three . - - ` - R-0 -17 --.8 a -5 I R-11 3 -2 -1 R-19 0 0 + 0 R-30 ; 3 1 1 U -value - --� 0.60. 444 -70 -46 0.50 -120 -58 38 0.40 -95 -46 30 0.30 -69 34 -22 0.20 -43 -21 -14 0.10- -17 -8 -5 0.08 -11 -6 4 0.06 -6 -3 -2 0.04 -1 0 01 0.02 4 2 1 0.00 10 5 3 Controlled Ventilation Crawlspace Exterior Slab Floor Number of stories Effective Pes crnt Glass R -value One Two Three R-0 -11 -7 -5 R-5 -4 -4 3 R-11 -2 -2 -2 R-19 -1 a -2 -2 4. Slab Edge Insulation 4 40 -90 Number of Stories--' -26 R -value One Two Three R-0 0 .. 0 0 R-5 8 5 2 R-7 8 6 3 F2 factor 29 -58 -20 0.90 -4 3 -1 0.80 -1 -1 0 0.70 2 2 1 0.60 6 4 2 0.50 9 6 3 0.40 12 8 4 5. Infiltration (Air Leakage) Specification Points Standard 0 ' 6. Glass Heat Loss Total Exterior Slab Floor Raised Floor Effective Pes crnt Glass U -value Stories Percent Effective Percent Glass . .51 to .41 to .31 to 0.30 or Glass Single Double .60 .50 .40 less 50 -121 -53 -39 -24 -10 4 40 -90 37 -26 -14 3 8 35 •75 -29 -19 -9 1 10 30 -61 -21 -13 -4 4 12 29 -58 -20 -12 3 5 12 28 -55 -18 -10 -2 5 13 ` 27 -52 -17 -9 -2 6 13 26 -49 -15 .-8 -1 7 14 25 -46 -14 -7 0 7 14 24 -43 -12 -5 1 8 14 �. 23 40 -11 -4 - 2 8 15 W 22 37 -9 3 3 9 15 21 34 -7 -2 4 10 15 20 31 3 0 5 10 16 • 19 -29 -4 1 6 11 16 I 18 -26 3 2 7 12 16 l 17 -23 -1 3 8 12 17 16 -20 0 4 9 13 17 15 -17 1 6 10 14 17 14 -14 3 7 10 14 18 13 -12 4 8 it 15 18 12 -9 6 9 12 15 19 ! 11 3 7 10 13 16 19 10 3 9 ti 14 17 19 , 9 -1 10 13 15 17 20 8 2 12 14 16 18 20 1B. Shading (Shade Closed) .. Exterior Slab Floor Raised Floor Effective Pes crnt Glass 7. Shading (Shade Open) Stories Mass Effective Percent Glass . EI(ecUve I (percent glass x SC) Two Three One %Glatt Nodi Ead SoA West STAN 18 -14 - %Glass North East South West Skylight 18 .5 ,. 1 _ 4 1 na ' 16 4 2 5 '' 1 ', na 14 4 2- 5 - 1 na , 12 '' 3 3 5 2 na-- 11 3 3 5 2 na 10 2 3 5 2 1 9 2. 3 5 2 2 8 2 3 5 2 2 7 1 3 4 2 2 6 1 3 4 2 3 ! 5 1 2 4 2 3 4 0 2 3 1 3 3 0 1 2 1 3 2 0 0- 1 0 3 1 -1 -1 ' -1 , -1 2 I 0 -1 .2' -4 -2 0 na = not allowed 11 -4 _ -2 1B. Shading (Shade Closed) .. Exterior Slab Floor Raised Floor Effective Pes crnt Glass Family Family Stories Mass (percent glace x SC) - 4 Stories EI(ecUve /CFA One Two Three One %Glatt Nodi Ead SoA West STAN 18 -14 -48 - a -64 na 16 -12 -42 -59 -55 na 14 -10 35 -50 ' -46 na -12 -8 -29 -40 ' 37 na 11 -7 -26 36 •33 na •10 -6 -23 31 -29 •74 ' 9 -5 -20 -27 -25 35 8 -5 -17 -23 -21.. -56 7 -4 -14 -19 -18 -47 6 3 -11 -15 -14 38 5 -2 -9 -11 -10 -30 4 -1 -6 -8 -7 -23 3 0 -4 -5 -4 -16 8 8 9 3.5 2 5 1 1 tI 1 11 -4 0 -2 3 4 3 0 9. Interior Thermal Mass Interior Exterior Slab Floor Raised Floor Mass Family Family Stories Mass Detached Attached Stories 0.00 /CFA One Two Three One Two Three 0.0 -8 -5 -4 -2 -1 -1 0.1 -8 -5 3 .1 0 0 0.3 -7 -4 -2 0 1 1 0.5 -6 3 -1 1 1 2 0.7 -5 .2 -1 1 2 2 0.9 -5 -1 0 2 3 3 1.1 -4 -1 1 3 4 4 1.3 -3 0 2 3 4 5 1.5 -3 1 2 4 5 5 20 -1 2 4 5 6 7 25 0 3 5 7 7 8 3.0 1 4 6 8 8 9 3.5 2 5 7 9 9 10 4.0 3 6 8 9 10 10 4.5 3 7 8 10 11 11 5.0 4 7 9 it 12 12 5.5 ' 5 8 9 11 12 12 1 6.0 5 8 10 12 13 13 - 6.5 6 9 10 12 13 13 7.0 6 9 11 13 13 14 , 7.5 6 10 11 13 14 14 8.0 7 10 it 13 14 14 8.5 7 10 12 13 14 .15 12 10. Exterior Wall Thermal Mass Exterior SM918- , Single - SEER Wall Family Family Muth Mass Detached Attached Family 0.00 0 0 0 0.20 3 2 1 0.40 5 4 3 +6 to 0.60 8 6 4 -15 0.80 10 8 5 more 1.00 13 10 7 -10 1.20 13 12 8 8.5 1.40 12 13 9 -5 1.60 10 13 11 . -5 1.80 10 12 12 -2 2-00 10 11 13 3 11. Heating System 1 = -2 SEorHSPF 9.5 0 (assumes ducts In attic) 0 Sum of t-6 0 0 25 or -24 to -14 to -4 to _ +6 to 16 or SE HSPF less -15 -5 _ +5 " +15 more 0.72 6.60 0 0 0 0 0 0 0.75 6.88 3 3 3 2 2 1 0.80 7.33 8 7 6 5 4 3 0.85 7.79 13 11 10 8 7 5 0.90 8.25 17 15 13 11 9 7 0.95 8.71 -20 18 ' 15 13 11 8 13 Sum of 1.6 9 Effective -25 or -24 b -14 b 4 to +610 16 or SE HSPF lest •15 -5 +5 +15 more 0.30 2.75 -73+ -64 -56 -07 38 30 na 3.41 -45 -39 -34 -29 -24 -18 0.40 3.67 -34 30 -26 -22 -18 -14 . 0.50 4.58 -10 -9 -8 -7 -5 .4 0.56 5.13 0 0 0 0 .0 0 0.60 5.50 5 5 4 3 3 2 0.70 6.42 17 15 13 11 9 7 0.80 7.33 25 22 19 16 13 10 0.90 8.25 32 28 24 20 17 13 1.00 9.17 37 32 28 24 19 15 Zonal Control Adjustment System Type Resistance 10 9 7 6 4 3 Other 6 5 4 3 2 2 12. Cooling System Interior Mass/CFA ..? : KAss SEER (assumes ducts In attic) Sum of 7-10 -25 or -24 b -14 to -4 b +6 to 16 or SEER less -15 •6 +5 +15 more 8.0 .14 .12 -10 -8 3 -4 8.5 -9 -7 -6 -5 -4 3 8.9 -5 -4 -4 3 -2 -2 9.0 -4 3 -3 -2 -2 -1 , 9.5 0 0 0 0 0 0 10.0 4 3 3 2 2 1 10.5 7 6 5 4 3 2 11.0 10 9 7 6 4 3 120 15 13 11 9 7 5 ,_13.0 20 17 14 12 9 Y 6 0.2 0.4 Effective SEER 0.6 1 - (SEER x dud efficiency) 1.0 21 23 Sum of 7-10 21 2.9 Effective -25 or ,24 to -14b -410 +6 to 16 or SEER last -15 -6 +5 +15 more 5.0 30 -25 -21 -17 43 -9 6.0 -12 -11. -9 -7 -6 -4 6.6 -5 -4 -4 3 -2 -2 7.0 0 0 0 0 0 0 8.0 9 8 65 1.1 4 3 9.0 16 14 12 26 7 5 10.0 22 19 16 13 10 7 11.0 26 23 19 15 12 8 1 12.0 30 26 22 18 14 9 13.0 33 29 24 20 15 10 3.6 3.8 4 4.3 4.5 4.7 4.9 5.1 Zonal Control Adjustment., 5.5 57 59 rj 0.9 1.1 1.3 13 1.7 1.9 21 10 8 7 6 4 3, 3.5 No Cooling System Installed 42 Stories 4.6 4.6 5.1 5.3 5.5 ' One -5 -4 -4 3 -2 -2 Two + 3 3 2 2 2 1 C 32 3.5 3.7 10 4.1 4.3 4.5 Single -Family Detached and Attached_ .F 5.6 5.6 6 62 60% 1 12 1.4 1.7 Unit Size (sQ 21 Water 2.S 1199 1200 1700 2200 2700 Heater Credit or b to to • or Type Type less_ 1699 2199 2699 more SG None 0 0 0 0 0 or Solar 12 8 6 5 4 HP HWR 8 5 4 3 3 55 WSB 5 3 3 2 2 1.4 POU 8_ •• 5 4 3 3 SE None 37 -24 -18 -15 -12 4.3 Solar -1 -1 -1 0 0 56 HWR -18 -12 -9 -7 -6 . 1.7 WSB -25 -16 -12 -10' -8 ' POU _ A-8 _ -12 -9 -7 -6 . n None -5 -3 -2 -2 -2 6.1 Solar 7 5 4 3 2 2 POU 3_ 2 1 1 1 IE None -28 -19'--14 4.3 -11 -9 4.0 Solar 8 5 4 3 3 • 64 POU -10 -6 .5 -4 -3 2.3 Multi-Famiy (indlvldual units) 2.9 3.1 - 3.5 Unit Size (sI) 4 4.2 Water 4.6 699 700 1200 i 700 2200 Heater Credit or b to b or Type _Type 2 lest 1199 1699 zoo more SG None 0 0 0 0 0 or Solar 14 7 5 4 3 HP HWR 9 - 5 3 2 2' 2 WSB 9 4 3 2 2 3.5 POU 9 5 3 2 2 SE None -45 -23 -15 -11 19 6.4 Solar 2 1 1 0 0 2.3 HWR -23 -12 -8 -6 '-5 10 WSB -25 -13 -8 -6 -5 5.3 PO -23 -112 _8 -6 -5 IG None -8 -4 -3 -2 i -2 - Solar 6 3 2 1! 1 _ POU 1 0 0 0._0_ 5.4 E None 30 -15 _ -10 -8 -6 7 Solar 18 9 6 4 4 29 PO -8 -4 -3 -2 4.2 Interior Mass/CFA ..? : KAss -:.t.z" It (ur9.t.d n_bt r TYPE 'I KASS WIKC a 4.2, tet exposed slob) ' 0% 5% 10% 15% 20% 2S% 30% 3S% 40% 45% 50% 55% 60% 6546 70% 75% 00% 65% 90% 95% 100% 105% 110% Its% 120% 125- 0% 0 0.2 04 0.6 0.6 1.1 1.3 1.5 1.7 1.9 21 23 2.5 2.7 2.9 3.2 3.4 3.6 3.6 4 4.2 4.4 4.6 4.6 5 53 10% 0.2 0.4 0.6 0.6 1 1.2 1.4 1.6 1.0 21 23 25 21 2.9 3.1 3.3 3.5 17 4 4.2 4.4 4.6 4.8 5 5.2 5.4 20% 0.3 0.6 0.6 1 1.2 1.4 1.6 1.6 2 2.2 24 27 20 3.1 3.3 1S 17 3.9 4.1 4.3 4.5 4.6 5 52 5.4 56 30% 0.5 0.7 0.9 1.1 1.4 1.6 1.6 2 2.2 24 26 26 3 3.2 3.5 3.7 19 4.1 4.3 4.5 4.7 4.9 5.1 5.3 5.6 58 40% 0.7 0.9 1.1 1.3 1.5 1.7 1.9 22 24 26 2.6 3 3.2 3.4 3.6 3.8 4 4.3 4.5 4.7 4.9 5.1 5.3 5.5 57 59 50% 0.9 1.1 1.3 13 1.7 1.9 21 23 2s 27 3 32 14 3.5 16 4 42 4.4 4.6 4.6 5.1 5.3 5.5 5.7 5.9 6.1 55% 0.9 1.1 1.4 1.6 1.6 2 2.2 24 2.6 26 3 32 3.5 3.7 10 4.1 4.3 4.5 4.7 4.9 5.1 53 5.6 5.6 6 62 60% 1 12 1.4 1.7 1.0 21 2.3 2.S 2.7 2.9 11 3.3 3.5 3.8 4 4.2 4.4 4.6 4.8 5 5.2 5.4 5.6 5.9 6.1 63 65% 1.1 1.3 1.5 1.7 1.9 2.2 2.4 2.6 2.6 3 3.2 3.4 35 3.8 4 4.3 4.5 4.7 4.9 5.1 5.3 55 5.7 5.9 6.1 64 70Y. 1.2 1.4 1.6 1.6 2 22 25 27 2.9 3.1 3.3 3.5 3.7 3.9 4.1 4.3 4.6 4.8 5 52 5.4 56 56 6 62 64 75% 1.3 11.5 1.7 1.9 21 23 25 27 3 3.2 14 16 3.6 4 4.2 4.4 4.6 4.8 5.1 5.3 5.5 5.7 5.9 6.1 6.3 6.5 80l: 1.4 1.6 1.0 2 22 2.4 26 2.6 3 3.3 3.S 3.7 3.0 4.1 4.3 4.5 4.7 4.0 5.1 5.4 56 5.6 6 62 • 64 66 85% 1.4 1.7 1.9 2.1 2.3 25 2.7 2.9 3.1 3.3 3.5 3.8 4 4.2 4.4 4.6 4.6 5 52 54 5.6 59 6.1 63 65 67 90% 1.5 1.7 2 2.2 24 26 2.8 3 32 3.4 3.6 3.8 4.1 4.3 4.5 4.7 4.9 5.1 53 5.5 5.7 5.9 62 64 ' 66 68 95% 1.5 1.8 2 2.2 25 27 2.9 3.1 33 3.5 17 3.9 4.1 4.3 4.5 4.0 S 5.2 5.4 5.6 5.8 6 6.2 6.4 6.7 69 _ 100Y. 1.7 1.9 21 2.3 2S 28 3 3.2 3.4 3.5 10 4 4.2 4.4 4.6 4.9 5.1 5.3 5.5 ' 5.7 5.9i 6.1 6.3 6.5 6.1 7 105%� 1.8 2 » 2.2 2.4 2.6 28 3 3.3 3.5 " 3.7 3.9 , 4.1 4.3 4.5 4.7 4.9 5.1 5.4 5.6 5.8 6 6.2 6.4 6.6 6 8 7 110% 1.9 21 2.3 2.5 27 29 3.1 3.3 3.6 3.8 4 4.2 4.4 4.6 4.8 5 5.2 5.4 5.7 5.9 6.1 6.3 6.5 6.7 69 7.1 115% 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 -3.8 4.1 4.3 4.5 4.7 4.9 5.1 S.3 5.5 -5.7 5.9 6.2 6.4 6.6 6.8 7 7.2 120% 2 2.3 2.5 2.7 29 3.1 3.3 3.5 3.7 3.9 4.1 4.4 4.6 4.8 S 5.2 5.4 5.6 58 6 .6.2 6.5 6.7 6.9 7.1 ; 7.3 125% 21 2.3 25 2.0 3 3.2 3A 3.6 3.8 4 4.2 4A 4.6 4.9 5.1 5.3 5.5 5.7 5.9 6.1 6.3 6.5 6.7 7 7.2 7.4 Point System Summary: Climate Zone 11.E SCORE CARD - - - - - - - - - ry - - Measures - ------ -- ---- - - Point Scores 1. Ceiling Insulation _ - _ 3 6 �or R -value 1381 _ U -value [0.030] 2. Wall Insulation 3- or �_ �Z•• R -value I1] ._,_U -value [0.098] _ _ _ .... _` 3. Raised Floor Insulation at or .. _ . R -value 1191 - U -value [0.037] ~4. Slab Edge Insulation or t".r�•;-n R -value [0] F2 factor [0.77] ^• -_ L. ._ '. _„ _ S. Infiltration __.. Standard ._._._.._ - _ 0 ( ) SS•G _ 6. -.Glass Heat Loss_ �;�� Type (double] U -value [0.65] _ M% Total Glass [ 16] ) Sum 13 7. Shading (Shade Open) o'-� . _- % Glass SC _ - Eff. % Glass :--,-- a. North - - G.'i •x - - - - b. - East -- __ 2. L x - _ _ t• �q y - o ' , _ c. South - - - 3 . y x - - - d. West iL.2 x e. Skylight p x 8.� Shading (Shade Closed) _ +- , _- � ` �-" - - •-- ---__ .. . Y =:> % Glass C Eff. % Glass a. North G. �l - x G _ . 22 -;;I b. East Z. L x = / X O c. South 3. X d. West 2• Z x e.. Skylight _ O x 9. Interior Thermal Mass - -- --- _ TYPE i MASS AREA s a -- - InteriorMass/CFA COND. FLOOR AREA 10. Exterior Wall Mass _ TYPE 2 rtAsAE s A ND $ -- Z Exterior Wall Mass . L R ARREA Sum 7-10 11. Heating System "y'L x = O Zonal Control? ( Y / N) SE or HSPF Duce Efficiency [0.78] - Effective SE or [0.72/6.6L HSPF 10.5615.151 12. Cooling System 41 S x _'7 9r Zonal Control? ( Y / N) SEER 19.51 Duct Efficiency [0.74] Effective SEER [7.03] 13. Water Heating fl ISG] Credit [none] I� PntntTotal: ��