Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
066-190-004
- 66-19-4J + Bruce Roethler I 380 Andover Dr., -lot 12, PPCC#3, Mag ali Permit`#2535-79B,P,E,M(new single family) ' / �f , -004 ' rilliam J.ndover Drive, Magalia�wtier Breezeway arld'Add partition- , a s=--- 066-190-004 99-2107 k is i HILL, WILLIAM &. CLEO 13803 ANDOVER; MAG ALIA i XY CONTR:.MALLORY CONSTRUCTION GARAGE/A7ACHE •h _ 1�� 4 :066=19-0-004 ` 99=2127 PM w `.HILL, William' * nt 13805 Andover Dr;' Magalia (HVAC) -;Del Johnson , r y �I C NOTES RESIDENTIAL A 066-190-004 PERMIT NO. _..HILL, WILLIAM'&'CLEO -2107 13803 ANDOVER, MAGALIA CONTR: MALLORY CONSTRUCTION GARAGE /ATTACHED J?4 --�� 11 SPECIAL CONDITIONS 11 SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER JOB FINALED (Date) 1M/�.-,- Signature ��/`" CHECKED BY V= OK 0 = Not OK = Not Applicable MOBILE HOMES = Not Ready Date ' MOBILE HOME UTILITIES (Plans) OK except Ws 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete MISCELLANEOUS Date DECKS, COV S, CARPORTS GARAGES (Plans) OK except Ws Z ng Requirements -Setbacks -Easements 4. Water; Location -Test -Easement Needed (Sketch) 3. 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete ' Wood Awn.; Posts- Beams- Rftrs.-Con nectors Shthg.-Frg-Bracing 6. Gas; Location -Test -Wrap;-/ /" L'ft. / P Nat. or / /"L"ft./ /'LPG 6. 7. Well Clearance & Disconnect f;tric 8. Utility Clearance Sidi g; Nailing -Veneer -Stucco -Mesh o f; Shthg-Roofing ,plooExt.; Steps -Doors -Landings Date Braced Wall Panels Card B-1 Date Card B-1 Date Dat Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except ft's Date f 7 1. Zoning Requirements -Setbacks -Easements Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. 3. Gas; MH Test -Demand -Valve -Connector Elec.; Receptacles and Lighting, Distance-GFI 4. Electricity; MH Test -Crossovers -Breakers -Clearances 6. 5. Drain; MH Test -Fall -Flex Connector Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 6. Water; MH Test -Regulator -Connector 9. 7. Water and Sewer Connected -C/O to Grade -HD Approval Plumb.; Cir. Test -Water Supply Test 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy 12. Permanent Foundation Only; License Decal Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COV S, CARPORTS GARAGES (Plans) OK except Ws Z ng Requirements -Setbacks -Easements otings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs.-Con nectors Shthg.-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors f;tric rm .; Sills-Anchors-Studs-Rftrs-Trusses Sidi g; Nailing -Veneer -Stucco -Mesh o f; Shthg-Roofing ,plooExt.; Steps -Doors -Landings 12. Braced Wall Panels Al Dat Card B-1 aO Date,/ / Car Date Date Card.B-1 Card B-1 095a Date f 7 FI ans) OK except It's 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 V= OK 0 = Not OK = Not Applicable = Not Ready RESIDENTIAL (: Date Underfloor (Plans) OK except #'s ni ng-Setbacks-Ease me nis-Flood-Slope tg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth Hangers -Post Caps -Anchors -Connectors Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Ring. 4. Ftg., Porches & Decks; Soils-Steel-/ /" Fig. Depth Fireplace Ties or Type A Flue -Fireplace Throat Clearance 5. Stemwalls, Main; Steel-Blockouts-Wrapped Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 6.. Stemwalls, Garage; Steel-Blockouts-Wrapped 50. 6a. Hold Downs and Special Anchors 51. 7. Slab, Steel-Wrapped 52. 8. Piers-Fireplace Ftg.-Steel 53. 9. D.W.V.; Fall-Fitting-Test-2 Way C/O-Sewer Test 54. 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test 55. 11. Water Pipe; Test-Anchors-Regulator-Service Test 56. 12. Electric Underground 57. 13. Plenums & Ducts; Clearance-Material-Support-Ins. 58. 14. Girders-Sills-Anchor Bolts-Joists-Vents-Crippies 59. 15. Access & Ventilation 60. 16. Insulation 61. Insulation -Walls -Ceilings Date Infiltration -Walls -Windows Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent-Access-Combustion Air Baffle 18. Water Pipe; Test & Anchor-Nail Protection 63. 19. D.W.V.; Test Fittings & Anchor-Nail Protection 64. 20. Shower Pan; Test, First Floor-Tub Access 65. 21. Test Tub & Shower, Second Floor-Tub Access 66. 22. Gas Pipe; Sixe & Anchors 67. G.F.I. & Bath Fixtures & Tub Access -Spa Date Elec. Trim & Subpanel, Breaker Sizes & Labels Card B-1 Date Card B-1 Date Stairs & Rails Card B-1 Date Card B-1 Date Fireplace or Stove, Clearance -Hearth ELECTRICAL (Permit) OK except #'s 71. 23. Fixture & Transformer Clearance-Ins. Protection 72. 24. Elec. Receptacles Spacing-Lights & Switches at Doors 73. 25. Size Boxes & No. of Conductors Stapled 74. 26. Romex Installed Close to Edge of Studs & C.J. 75. 27. Equip. Ground made up w/Mech Fasteners-Bond Gas & Water 76. 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 77. 29. Subfeed Wire Size / / ga. Cu or M-A.C. Wire Size / / ga Cu or AI 78. 30. Range Circle / / ga Cu or AI-Oven Circ. / / ga Cu or Al Insulated Neutral ❑ Yes Q No 79. 31. Service-Riser Conductors & Ground Main Disconnect 80. 32. Equip. Clearances Panels-Motors-Mech. Equip. 81. 33. Clothes Closet Light-Shower Light-Spa Light 34. Smoke Detector 82. Following Insild./Drive J Yes 0 No/Walks 0 Yes 0 No/Planters 0 Yes 0 No Date Stucco Brown -Finish Card B-1 Date Card B-1 Date A.C. Unit Disconnect, Electrical -Plumbing Card B-1 Date Card B-1 Date Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings MECHANICAL (Permit) OK except #'s 86. 35. A.C. Ducts Insulation & Support 87. 36. Vent Fan, Exhaust above insulation 88. 37. Condensate Drain & Overflow, Size & Grade 89. 38. Furnace-Vent Access-Comb. Air-Return Air Vent 115 outlet 90. 39. Attic Access & Platform if Furnace in Attic 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval Date Card B-1 Date Card B-1 Date 94. Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s Date 40. Sits Proper Materials & Anchors Date 41. Walls Studs-Nailing Spacing & Braces-Plates-Sound Date 42. Bearing Walls over Girders & Floor Nailing Comments at Final: 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings-Stairs-Chasers-Tubs 45. Headers & Beams-Size & Bearing jingle & Duplex) Date FRAMING (Continued) 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Ring. 48. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior/Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext. Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance 73. Elec. Outlets & Receptacles at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 77. Plb., Elec. & Mech. Equip. Listed for Location 78. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard Rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 82. Following Insild./Drive J Yes 0 No/Walks 0 Yes 0 No/Planters 0 Yes 0 No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throughout House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: f: COUNTY OF BUTTE BUILDING DIVISION is. DEPARTMENT OF DEVELOPMENT SERVICES .j 411 Main Street a Chico, CA • (530) 891-2751 "f 7 County Center Drive • Oroville, CA • (530) 538-7541 CORPECTION NOTICE 2�a 7 PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, ;r. please Fontact this office immediately. 5 COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 PERMIT NO. (Rev. 12/96) APPLICATION ANb PERMIT W7 ASSESSOR PARCEL NUMBER 066-19-0-004 ZONING R-1 BUILDING PERMIT OWNER W L D EO l TELEPHONE 873-0451 SO. FT. OCC. BUILDING VALUATION • OWNERS MAILING ADDRESS 13805 ANDOVER DRIVE, MAGALTA n U CONTRACTOR'S NAME MALLORY C C TELEPHONE 7— 5 CONTRACTORS MAILING ADDRESS 22 DANA CIRCLE, MAGALIA CA 99954 CONSTRUCTION LENDER LENDER'S MAILING ADDRESS Fireplace Total Valuation $ 8,280.00 ARCHITECT OR ENGINEER ELT ENGINEERING LICENSE NO. Filen Fee $ 20.00 Permit Fee $ lub.ug_ ARCHITECT OR ENGINEERS MAILING ADDRESS 4790 CLARK ROAD, PARADISE CA 95969 Plan Checking Fee $ 70.20 BUILDING ADDRESS imm ANDOVER DR, MAGALIA$ Energy Plan Checking Fee $ PERMIT FEE $ LOT NO. 4 T�+ SUBDIVISION'${JprADISE i�(Ej�IICC PARCEL MAP 03 PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE X SF O" Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat um water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition] Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: ADD ATTACHED GARAGE 20 X 23 Gas i in stem 1 - 5 outlets 15.00 Buildin sewer 15.00 Mobile Home ISI G1 W1 Ca20.00 PERMIT FEE $ ELECTRICAL PERMIT Filing Fee 20.00 LE Main Service 2o.A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is Afull force and effect. �j e� License Class Lic. NO. S ` !' Z OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale,— ❑ QI, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200ATO 1000A 46.00 NEW CONST. DWEWNOOCCUP, EL OR ADDNS. ( a ACC. BLDS.NEW SO C� '98 3.5Q�: NON -RES D. MU - CI CUITS 97,50 POWER APPARATUS d SINOI.E OUTLET CIR. Ex. Occup. OUTLET OR FIXTURES BAIL @'.50 Ex. Occup. OUTLETS R� G� 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 23.00 PERMIT FEE $ 71 .98 WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. IR I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My worker gomgensati n insurgrice carrier and policy number are: Carrier --- T,r u1�( Policy Number I/ 3 S — (The above sections need not be completed i the permit is for work of a valuation of one hundred dollars ($100) or less.) [I1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' laws of California, and agree that if I should become subject to the.� workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. q c� X Date / — �� — t y Signa4W of Applican Owner ❑Contractor ❑Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE 270.18 TOTAL FEE $ �HAZ. p. FEES IMP FLOOD C PARCELcompensation This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. /_ By!�/v "y 6 �� Da PERMIT EXPIRES ON Li% �� � ate Receipt No. 277111()Q/- / /a79 lid I .7_�_LL WHITE-D.D.S.-B. D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT y , COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION ' 7 County Center Drive - Oroville, California 95965 - Telephone (530) 538-7541 PERMIT NO. (Rev. 12M) APPLICATION AND PERMIT I/07 ASSESSOR PARCEL IyMeERj� (/ ZONING�p -' BUILDING PERMIT OWNED I L,L/i I ((ok"Cl G �2 ! ELEPHONE ` ? _� 155 r7; SO. FT. C BUILDING VALUATION OWNERS MAILING ADDRESS CONTRACTOR'S NAME 1/0 TELEPHONE CONTRACTORS y� ADDRESS ( C.57!L CONSTRUCTION LENDER V\ LERp, LENDERS MAILING ADDRESS Fireplace Total Valuation $ s( AR CT OR ENGINEER LICENSE NO. Filing Feb $ 20.00 ARCHITECT OR ENGWEER•S MAJUNGAp DREs S % Q &(-1 ,!- !Z � X �u/ L se C/¢ S 15_S1/% Permit Fee $ Plan Checking Fee $ =1 BUILDINGADDRESS u c.• c cr Energy Plan Checking Fee $ $ PERMIT FEE t LOT O SUSDN NS NAME � r [ c4 PARCEL MAP I D 3 1 PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF % Duplex ❑ Mobilehome ❑ Other sPECFY EacR-TC&p 7.00 Solar orLelump water heater 23.00 Water piping 15.00 Each as water he r vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other Describe Work: / --' Gas pipin system 1 - 5 o is 15.00 —Building sewer 15.00 Mobile Home S G W @20.00 PERMIT FEE t )��fj.•. ELECTRICAL PERMIT Fling Fee 20.0 Main Service -Gov oR LESS 200A OR LESS 23.00 ��--ff gal �a , O / 1 LJ 0 `• I 1 l Main Service 20GA TO 1000A 46.00 NEW CONST. DWELLWG OCCUP. so. OR ADONS. ( 6 ACC. eLDS. 3.5¢Fr, r NEW CO MULTI- ULTI.OUTLET NON -REBID. � @7.50 PS r APLIUS OEOACIR. EX. Occup. OUTLET OR FIXTURES BAL p I.50 EX. OCCU QED APPINS. OR OUTLET'S RESID. EA 5•00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 1,0 IF PERMIT FEE $ 7/. q 53 MECHANICAL PERMIT Fling Fee 20.00 Heatin Cooling Hood 6.50 Ventilation PERMIT FET: i Mobile Home Installation Fee $ Energy Inspection Fee $ occ NST. tvPE TOTAL FEE $ HAz• D. FEES I P FLOOD I CDF I ffL I PO HD ISSUE This permit is hereby Issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date PERMIT EXPIRES ON re COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 PERMIT APPLICATION DATA SHEET OWNER: ASSESSOR PARCEL NUMBER: Olv6 l �D / /CST Proposed Building U e: Building Inspector: L Date: _4?Zj .- �Cf At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: Date Received By ❑ 1. All items have been submitted.------------------------------ Plot plans, 3/4 sets, signed by the preparer of plans. ------ Vkw Complete plans, 3/4 sets, signed by the preparer of plans. El 4. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. - r (0- 0 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! -------------- ❑ 6. Energy Design Compliance and supporting documentation. ---------------------------------------------------- ❑ 7. Statement of Intent for Non -Heated and A/C Buildings.--------------------------------------------------------- ❑ 8. Hazardous Material Form. ------------------------------------------------------------------------------------------ ❑9. Manufactured Home data and installation instructions including Tie Down Specifications .------------------ ❑ 10. Fees of $ ------------------------------------------------------------------------------------- ❑ Impact fees as shown on the attached schedule.--------------------------------------------C�-------------------- California Department of Forestry plan approval/fees.-----y-1�'`----_f -------------------- ❑0113eTlood elevation certificate. ----------------------- ----------------------------------------------------------------- �'4. Sanitation and plot plan approval Health Department. ------------------------------------------- ❑ 15. City of Chico plumbing permit. ----------------------------------------------------------------------------------- ❑ 16. Plot plan and business license approval from the City of Biggs. ----------------------------------- I 17. Planning approval for (A) Use: (B) Parking: -------------- ----------- 0 18. Contact Land Development about ElImprovements, 11Drainage, ElLegal Parcel. ----------------------- El19. Encroachment Permit for driveway (construction approval prior to occupancy). ---------------------------- ❑ 20. Pre -inspection for required Request to Building Inspector on E12 1. Contractor's license information. (Number, Name Style, Classification). ------------------------------------ 0 22. Workers' Compensation carrier and policy number. ----------------------------------------------------------- 023. Owner -Builder Verification (Given to owner ❑, Mailed to owner 0) - -------------------------------------- 024. Letter of signature authorization. ---------------------------------------------------------------------------=---- ❑25. Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- E326. ------------------------------------------------- ❑26. Letter of intent on building use. ----------------------------------------------------------------------------------- ❑27. Manufactured Home utility clearance. --------------------------------------------------------------------------- ❑28. Existing violations and/or expired permits. ---------------------------------------------------------------------- ❑29. 0433 A, ❑Grant Deed, ❑ M.H. Title, ❑ Check to H.C.D $ .---------------- 030. -------------- ❑30. Other:------ When you issu l e ermit, rocess follows El Mail to owner, ❑Mail)// t�oj contractor. ❑Telephone 3 ` and hold for pickup at ©2V office. ❑ Deliver with inspector. (Date) Applicant Date: % /_3 - eP Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, ❑ Air&61lution 4i Sate: By: Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Other: Date: By: 1. Index permit application for the above items numbered: _ *Plan Check List 2. Additional items required: Contractor, design own as advised of the above required data by ❑ phone,;$ mail, ❑ Building Division counter, by Date: a2 - Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Plans reviewed by: A Date: Plans approved by: Date: _3 Sets of plans on hold m ❑ Plan Cabinet,,RA.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division TO: FROM: SUBJECT: io Building Department Environmental Health Sanitation Clearance a E. H. USE ONIY Piot Pian Attached 4 Floor Plan Attached Sant to B.D. /,4 /3 SAyLkyzA Owner Location AP# Plan Approved for: Sewage Disposal �Y Water Supply: Public Private Well Clearance for ---dwel,igg. Other 6&LLrr 0 pu eAgIg 4 n� Hold final for: Final clearance O.K. for: (VOTE: Environmental Health Specialist 9/96 '9-%r-99 Date OWNER 9�fT 1 COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 SCHEDULE OF FEES DUE '0.4,i '/ 1. BUILDING PERMIT FEES -- Balance Due ................ $ -- Additional Fees Due ........... $ -- Additional Fees Due ........... $ -- Revised Plan Checking Fee ....... $ 2. SCHOOL DISTRICT FEES (paid at District Office) 3. SHERIFF FEES (paid at Building Division) Residential ........ x $360.00 = $ Units Commercial (sq.ft.)... x $0.03 = $ Sq.Ft. 4. URBAN AREA FEES (paid at Building Division) Residential (per unit) . x - = $ #Units Amt. Commercial (sq.ft.) .. x _$ Sq.Ft. Amt. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) YV7. SRA FIRE INSPECTION AND PLAN CHECK —$89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion #, ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER A.P. # JQ616-10— 001�1 DATE q -/.--T RECEIPT # DATE REC At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICAN� DATE 7— 0 Pursuant to Government Code Section 66020, you are hereby notified that items 2,3,4,5,6,8,9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original -Building Div. 2nd Copy - Applicant 3rd Copy - Owner (Rev. 2/97) WE FILE COPY' Building Permit Number: 99-2107 Owner Name: William and Cleo Hill Plan review by: Glenn Gibbons Residential Construction Requirements IMPORTANT This set of plans and specifications MUST be kept on the job'site at all times and it is unlawful to make any changes or alterations on same without written permission from the Building Division, County of Butte. All materials and workmanship. shall be in accordance with recognized good practices and of a quality prescribed for the specific use in the 1998 California Building Code (1997 U.B.C), 1998 California Plumbing Code ( 1997 U.P.C.), 1998 California Mechanical Code (1997 U.M.C.) and the 1998 California Electrical Code (1996 N.E.C.) The following items are separated into two categories (general and specific). The "general" items are for your reference and are not specifically called out on the plaris by the plans examiner. These items MUST be complied with, if applicable, and it is the builder's responsibility to comply. The "specific" items have been keyed to the plans. If an item is inadvertently left out or missed, it does not relieve the builder of any responsibility for code requirements, general or specific. GENERAL REQUIREMENTS • Provide windows for natural light and ventilation. (Sec. 1203, U.B.C.) • Provide required room dimensions and ceiling height..(Sec. 310.6, U.B.C.)' • Provide lights, switches, and receptacles for maintenance of mechanical equipment. (Sec.306, U.M.C.) • Provide approved vent and adequate combustion air for gas water heater and/or furnace. (Ch. 7& Ch. 8, U.M.C.) • Provide minimum one 3'-0" exterior door. (Sec. 1003.3.1.3,U.B.C.) • Provide adequate clearance and type A flue for fireplace/woodstove. • All stairways to comply with Sec. 1003.3, U.B.C., for rise, run, headroom, width, landings and handrails. • Hallways to be minimum 36" wide. (typical) out ���TY, �riIr T • Underfloor access and ventilation per Sec.2317.7, U.B.C. 801��d jNEENT APYRO D 2 of 3 Building Permit Number: 99-2107 Owner Name: William and Cleo Hill Plan review by: Glenn Gibbons • Attic access and .ventilation per Ch. 15, U.B.C., • Provide approved flashing at all exterior openings • Provide 18" platform for appliances/equipment in garage capable of producing a flame, spark or glow. • Provide protection of appliances in garage from vehicular damage. • Closet lights per Article 410-8 N.E.C. • Provide certificates of conformance for all glu=lam beams. • Provide approved spark arrester at all chimneys/type "A" flues. • Provide 1/2"x 10" anchor bolts @ 6' o.c. max. and within 12" of all joints. Provide 2"x 2"x 3/16" steel plate washer @ each bolt. (Sec. 1806.6, U.B.C.) • Provide 1- #4 bar top and bottom of footing, U.N.O. (Sec. 1806.7, U.B.C.) • Guardrails to have minimum 36" high top rail, with intermediate rails spaced that a 4" sphere cannot pass through (Sec. 509, U.B.C.) • Veneer per Ch. 14, U.B.C. • Skylights per Sec. 2409 & 2603.7, U.B.C. • Protect plastic foam insulation per Sec. 2602.4, U.B.C. • Electrical, mechanical, and plumbing construction (not plan reviewed) shall comply with the current editions of the National Electrical Code, Uniform Mechanical Code and Uniform Plumbing Code. • Provide plumbing fixtures, water closet clearances and shower sizes per U.P.C. SPECIFIC REQUIREMENTS 1. Provide safety glazing in all hazardous locations per Sec. 2406, U.B.C. 2. Garage firewall, door size and self -closer per Sec. 302.4, U.B.C. 3. Install smoke detector per Sec. 310.9, U.B.C. 4. Special roof covering required, class C minimum. 5. Living area over garage, 1 hr. construction required on garage side, including supporting walls, posts and supporting beams. 6. Provide 2 separate exits from third story. 7. Every bedroom shall have at least one operable window or. door. Windows shall have a minimum net clear openable area of 5.7 square feet. Additionally, the window shall have a minimum net clear openable height of 24" and a minimum net clear openable width of 20". The window sill height shall not be more than 44" above the floor (UBC 310.4.) ................................................................................................................ ............................................................................................................... ................................................................................................................ ............................................................................................................... ................................................................................................................ ,� Blue —Engineering BUTTE ai fy • Green = Brace wall panels WILID"ING DEPARTNAIENT a Yellow• A P. 6 0 ${ �„ Q) 3 of 3 Building Permit Number: 99-2107 Owner Name: William and Cleo Hill Plan review by: Glenn Gibbons COMPLY WITH ITEMS INDICATED BELOW Your parcel lies within a designated 100 -year flood plain. Finish floor, electrical, ❑ H.V.A.C. equipment and services shall be a minimum of one foot above the elevation shown on the attached Flood Elevation Certificate. A Post Flood Elevation Certificate will also be required Note: We will normally accept the following as compliance with the flood elevation requirements: 1. Building is anchored to concrete stemwall system with conventional anchor bolts. 2. Building plate on top of stemwall to be one foot or more above the 100 -year flood elevation. (Plate height' less than 24" above grade, or engineered design required). 3. Electrical, heating, ventilation, plumbing and air conditioning equipment and facilities located above the plate. 4. At least 2 openings in exterior walls, located on opposite or adjacent walls with a total net area of not less than 1 square inch for every square foot of enclosed area. 5. The bottom of the openings shall be no higher than 1 foot above grade. 6. The openings may be screened or covered with other devices that will permit automatic entry and exit of floodwater. ■ Parcel lies within the State Responsibility Area (SRA). Comply with attached requirements. ❑ Fire sprinklers are required in this structure. ❑ The following parcel map requirements shall be met: ■ ' All structures and equipment including overhangs shall be clear of all easements. A setback of 5' from the side and 15' from the rear property lines and 20 feet (25 feet if Federal Aid Route) from the edge of the right of way shall be clear of structures and equipment except for a 2 foot overhang. ❑ Expansive soil may be encountered .on this site. This condition may require the foundation to be designed by a California registered engineer or licensed architect. BUTTE WNWY BllLIDAN G &EP A R T I E N T A fflmml� LMMUDI MG tj- MI A'W D �HLALL BE ��CEPT FOP, A, 2 v m PLOT PLAN SCALE: 1"=16 FEET 13805 ANDOVER DR. POA#03-04 A -P#66- 19-'& CDF FIRE SAFE REQUIREMENTS lob - � �i -l� � CI q , 2-10 7 AP# . PERMIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made a part of this permit. These requirements -are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building- Department for compliance. [x] 1272.00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. Driveway Standards [�f 1273.02 Surface. All driveway surfaces and structures (bridges, 1273.07 culverts and other app-artenant structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, iriclud- ing sedans and.fire apparatus weighing up to 40,000 pounds. 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius 1. No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional sur- face ur-face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. 2. The length of vertical curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. Width. All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of .3- W [ &73.05 273.05 21 7 0. 10 qu 4 2. The length of vertical curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. Width. All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of .3- I qq-2,(0 , �rt(.,��.v, AP # PERMIT # NAME [)�] 1273.10 Turnouts. Driveways exceeding 150 feet in length, but ,1 less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. [�] 1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall .be within. 50 feet -.of the building. 1273.11 Gates [�J 1. Gate entrances shall be at least two feet wider than the roadway it serves. [�) 2-. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [ ) 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall_be used. Fuel Modification 1276.01 Setback for Structure Defensible•Space. 1. All parcels 1 acre azzd larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from 411 property lines and/or the center of the road. [kj 2. For parcels less than 1 acre, local jurisdiction shall provide for the same practical effect. See Other Requirements below. [�] 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping, burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of .•, road construction �r fi:tal inspection of a- building permit. "' Page 2 of 3 AP # (Fq,-2-/ 0 7 PERMIT # Other Reauirements 41 If �V/ L� NAME [ ] If Building Setback is 15 to 30 Feet: Class A or B roof Enclosed eaves [�1 If Building Setback is Less Than 15 Feet Choose any 3 of the following: - Metal or no doors on.side toward property line with insuffi- cient setback - Class A or B roof with enclosed eaves - Interior automatic sprinkler system per NFPA 13D - Glass area not to exceed 10% of wall area toward property line with insufficient setback - Siding from the following list: Stucco - 3 coat Hardi-Board or Plank Masonry Masonry veneer Metal Other Butte County Fire Department approved materials [ ] na ' ate Signature Page 3 of 3 —4 MALLORY CONSTRUCTION Bryan MaRmy 6122 Dana Ckde cA s695a 63o est 366 630621-6623 �� 6iarn $ aeo �tal BUTTE CO U N 53 A,.:WIW D*l FL.,0-0-R P.LA.--N B U I L D I gh! .9 D, 12, 22010� M CA 95KA t93 Loii4 SCALE: 1/8"= 1 F OTP PAGE s Proposed Addition Sheetrock floor to Existing House ceiling b -- — — �— GARAGE zra• x f e�-a• a m 1 e 1 3 I ,�•� I .i --. _ I. _ @stcdP�1 16070 B.e yparel•' '. — __ __ _. 6npYnen➢ Octal �'d MALLORY CONSTRUCTION Bryan MaRmy 6122 Dana Ckde cA s695a 63o est 366 630621-6623 �� 6iarn $ aeo �tal BUTTE CO U N 53 A,.:WIW D*l FL.,0-0-R P.LA.--N B U I L D I gh! .9 D, 12, 22010� M CA 95KA t93 Loii4 SCALE: 1/8"= 1 F OTP PAGE s CONSTRUCTION: DE.TAJjr.e MALLORY CONSTRUCTION Bryan Mallory 8122 Dana Circle MmqWlK CA 85954 530 873-1365 _. . p. .,... ... •_.. :.::.. .... ..., r. 1,._._.: .... • .., ..... _,..-tom-.: _. .. ..,:. � ... r..,. _ _..... .. .... .. � _ _ _ _ tet: I, r. .a.^r�..cv.z _. .,.....c.'v-.S•^+^t. _r,_ �.... ..a>'.v ..[ K .. .. 4 � •��..;.�:'^: i. ,w��'.t,�. IT- MALLORY CONSTRUCTION Bryan Mallory 8122 Dana Circle MmqWlK CA 85954 530 873-1365 FRONT LEFT MALLORY CONSTRUCTION Bryan Mallory 6122 Dana Circle Magalia, CA 95954 ,;° William & Cleo Hill f�L 13805 Andover Drive WA 9595' dditin BviLDIN � izp 6Cr19- Unit # 3 Lot X34 AP pfto EF PAGE # n, uMal FRONT LEFT MALLORY CONSTRUCTION Bryan Mallory 6122 Dana Circle Magalia, CA 95954 ,;° William & Cleo Hill f�L 13805 Andover Drive WA 9595' dditin BviLDIN � izp 6Cr19- Unit # 3 Lot X34 AP pfto EF PAGE # m N ....{.t_ncr:_2::'��r'1€'`"•':ti%v:r �.r.�s 5�+nv'......�5ni.:..q•,',.Sifpr}i'•;:.y.sr��bya:.a,,;1..::,�: - _: Yir riaY.:�i.: r ; STF.tii'+tiisn`J".5.:'D7��r7.r'. .n?C'*.?'k•.r.:.?'K"!-.i+': - _ : ��:., c;i.,ytaal��.iN;"'2T i;'!irraAin - .:.F;;S?i,'.�;-,;:d::;yi t;.. a?i>a ;: .g+t�a r: ��✓'i':i: pc cs�::�n•x- - - J�.q.: rfi,:!=>(_'i'C;'^"f�� _ .. a:.:. s'.�,>..�a� ri.r;::.'-:.a;;::.',;•c:�. . 'dr :`pi<�::y�n'�::=r.';. .,. - '•;i::d5. .•�d+; - - r 1/2" x 10" A n c h o r Bo I is At 6' 0.Ca _2X 4 P T M S Concrete S I a6 �� Ttg 2 pc o 1/2" Rebar ----------------—-------------------------- '-------------------------- ----------------------- , BIJ COUNTY PART" 1 BUILDING FO -OT I NG �ppb0 1 f o o t---- , DRAWN BY., sY /SGT �.,,__ SU/B�JEECTp ��i�CICTUi�/fL�/�/�T�IL O �oole XIA4 L JOB NO, 17/011 /3805 +A1,00YEie ,ae, t-1/fq FFG /,Q, C-4, pFESSIONq m No. 3243 �j9lF FICA��F���\ S/I7PSO.t/ ST6224 0.< srU,0 Ox P T, D. F, f2� w 2—%2"��. ao/ -s CONT #Fid D 6-A-- — 6 x /2 f #/ ne & ;c sre vcTve�r�) P�- y Covc. c�/.ea Covc. moo ri,�c W/ 4¢ To" 3t' SOTj,' IF LcT [EHOH EMflRIa 5790 CLARK RD., PARADISE, CA. 95969 (916) 872-0254 W C I L rr' PLY o,C 0S13 S/,0110G' . �-8 IF LcT [EHOH EMflRIa 5790 CLARK RD., PARADISE, CA. 95969 (916) 872-0254 S T R U C T U R A L ---------------------------- C A L C U L A T I O N S ---------------------------------- F 0 R G A R A G E A D D I T I O N WILLIAM & CLEO HILLRESIDENCE 1.3 8 0 5 A N D O V E R D R I V E M A G A L I A C A 9 5 9'5 4 M A L L O R Y C O N S T R U C T I O N 6 1 2 2 D A N A C I R C L E MAGALI.A, CA '95954 F L T ENGINEERING 5 7 9 0 C L A R K R 0 A D PARADISE, CA 95969 5 3 0) 8 7 2- 0 2 5 4- 15 F LT CSM ONEERON(a CML • STRUCTURAL (916) 872-0254 FAX (916) 872-9331 5790 CLARK ROAD, PARADISE, CALIFORNIA' 95969 f WSJECT: V. 'f C. t ,e 6' /ALT • DATE: SHEET No. pI OF Z CHECKED fffl DATE: JOB No. MECT: C . /ATG f0� "e6=/OL Iyita�if�E e3d�1�.4��ov� ,?�,�., /`�•����-/,4c, Com, T Sl�,Bc/6�T .T/WE" L!S ���GGi.�� DF wOO2� �,e.¢/7E corJST ,cJ ,ay �,¢�Go ey C�O,dsT.�v+✓170.1J. �oQR�FESS/p�,ql L. Coves /9�7 UBC y e rn 2 uj 0.3 3 civ GG = 30 — S;vJ pF CAL1F� 'Cox 113 x -lit; J /19fy CIO 7 F LST EMMMEERNG CML • SIRUCTURAL (916) 872.0254 FAX (916) 872-9331 5790 CLARK ROAD, PARADISE, CALIFORNIA 95969 • p&ECT: STRUCTURAL C ALCMLAMOONS W. / `7— mm: SHEET No. Z OF Z CHECKED BY:. DATE: JOB No. 91624 SUBJECT: t t 9.7y `��ic _ . U O l'C /6r 3 X / t/'.� �'%V iC /. /c�= l 9�'• OG3fr/ � - ��� ', Cr K ` ,.�- / � r Y ✓ X !�r J / � t /b r � (� _ ��Z Jr // �� V G� `^ r RDx • >�,c/6 3 /Z sQ, Gv` ' � /, f` ,G3r — cL = �. rS. d' y CTP' -- � _ / �� �/. �'7�'t 3.6•¢� _ �. Z 7 'C�� g. /� 'C vrF "� 6',x /Z�/ ¢ � (/'?� yG�. rls� Dv If- x�E C PvsTs oe &/z "'X //%�¢- 5`'x4' y�oc�IVCZ-T }�oS'Ts Ta AP e , �v/ST6'ZZg STae� � /4' �Z-7. 0'�' D� ��T. �10� , Z -Ar y �• r�OGTS �.¢ . S'r GC% �if-�t/FG 1✓r: Co,�c /Z'sQ, �n/.v. 7":o4>77vX $Y / :nuc / / / Sl1/B�l1ECT. ` 7,eUC7"V C,4 Z),FT, 4IL .:'t_E? NO. CMK7. LIT7r.Tc - 'yl/T y E �XI-1XI-14411-QOle 4G!OB NO. w— c, HILG. ,2FS'/O, /3805 y.¢G/,q C.+, Q�pf Ess/ �F,y rn c� ,,, No. 32 ^� ��qTF lOF CAL�F�\ 'CO u/T Sri x !�/a 2.0E S7'�'UCG.4iy ovE.e 2 x roP S sv� /ted A; 0. rn woe. -C1M=S0,V S7-6224 p'Fi4. OTf�F�2 �/� SPG/C'i4.8C.E� TT 11 I 4� FSE POST. � I j I i ► 111 II sre vcTv�e.¢G) I �' SHFi�.e.lvi¢GG `C � I � � ' 8c� � 6 0• c, c� �y i.j roc, Esq T; �' I, BOL TS �r sip, Covc, cvea covc. moo r�,�y W/ ¢row ,8orr, POR rXL die ilk DST,¢/L N• r. S. iS/TE T� .e . TO CDX Y. — ,4�)',e OI��T� P�- Y. O,C OSB S/D/.V,q . ` ZI U- LSU MaDU E'lEROM 5790 CLARK RD., PARADISE, CA. 95969 (916) 872-0254 G E N E R A L S T R U C T U R A L N 0 T E S 1. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO STARTING OF CONSTRUCTION AND THE DESIGN ENGINEER SHALL BE NOTIFIED OF ANY DISCREPENCIES WITH ANY WORK SO INVOLVED. 2. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ON PLANS SHALL BE OF THE SAME NATURE AS THOSE SHOWN FOR SIMILAR CONDITIONS. 3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLY WITH THE PERTINENT SECTIONS OF THE "CONSTRUCTION SAFETY ORDERS" ISSUED BY THE STATE OF CALIFORNIA AND ALL OSHA REQUIREMENTS, AS THEY APPLY TO THIS PROJECT. THE DESIGN ENGINEER AND THE OWNER DO NOT ACCEPT ANY RESPONSIBILITY FOR THE CONTRACTOR'S FAILURE TO'COMPLY WITH THESE REQUIREMENTS. 4. ALL PHASES OF WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE LATEST APPLICABLE EDITION OF UNIFORM BUILDING CODE. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE DESIGN AND CONSTRUCTION OF ALL FORMS, BRACINGS AND SHORINGS REQUIRED FOR CONSTRUCTION. 6. THESE PLANS ARE NOT COMPLETE UNTIL REVIEWED AND ACCEPTED BY THE LOCAL BUILDING OFFICIAL AND STAMPED AND SIGNED BY THE DESIGN ENGINEER. 7 FOUNDATION DESIGN IS BASED ON ALLOWABLE SOIL BEARING PRESSURE OF 1500 PSF (NO SOILS REPORT). 8. ALL FOUNDATIONS SHALL BEAR ON LEVEL GRADE AND CHANGES IN ELEVATION SHALL BE MADE BY STEPS OF 24" MAX. HEIGHT AND 36" MIN. WIDTH. CONTINUITY OF FOOTING REINFORCING SHALL BE MAINTAINED. 9. ALL.SAWN STRUCTURAL MEMBERS AND THEIR FASTENING SHALL CONFORM TO UBC AND SHALL BE OF MINIMUM GRADES AS FOLLOWS: 2x & 4x MEMBERS - D.F. NO.2 EXCEPT NON BEARING 2x STUDS, PLATES, 2x BLOCKINGS - D.F. STUD GRADE 6x MEMBERS - D.F. NO.1 10. LAMINATED VENEER LUMBER SHALL BE OF GRADE 2.OE STRUCLAM (SL) AS MANUFAC- TURED BY WILLAMETTE INDUSTRIES, INC. (ICBG REPORT NO. NER-472) OR 2.0E PARALLAM (PSL) AS MANUFACTURED BY TRUS JOIST MacMILLAN (ICBG REPORT NO. NER-119) OR APPROVED EQUAL. 11. ALL WOOD IN DIRECT CONTACT WITH EARTH OR IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED DOUGLAS FIR OR FOUNDATION GRADE REDWOOD. 12. ALL PLYWOOD SHALL CONFORM TO APA U.S. PRODUCT STANDARD PS 1-95. 13. WOOD NAILING SHALL BE PROVIDED WITH COMMON WIRE NAILS OF SIZES AND NUMBERS PER TABLE NO. 23 -II -B-1 OF UBC EXCEPT WHERE MORE SPECIFIC NAILING IS NOTED ON PLANS. EQUIVALENT CAPACITY FASTENERS APPROVED BY ICBG MAY BE USED. 14. METAL CONNECTORS NOTED ON PLANS ARE AS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY. EQUIVALENT CONNECTORS APPROVED BY ICBO MAY BE USED. 15. ALL ANCHOR, LAG AND MACHINE BOLTS SHALL CONFORM TO ASTM A307 REQUIREMENTS W FOR UNFINISHED BOLTS. 16. PREDRILLL FOR NAILING INTO EXISTING WOOD MEMBERS AS APPLICABLE TO AVOID SPLITTING AND CRACKING OR USE SELF -DRILLING WOOD SCREWS OF EQUAL CAPACITIES. THE ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE SHALL BE 2000 PSI MINIMUM IN 0V 28 DAYS. REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A615, GRADE 40. I�IM. SPLICES IN CONTINUOUS REINFORCEMENT SHALL BE 30 BAR DIAMETERS OR 24" MINIMUM. "0 REINFORCING, DOWELS, ANCHOR BOLTS, ANCHORS, ETC. TO BE EMBEDDED. INTO CONCRETE SHALL BE SECURELY POSITIONED BEFORE PLACING OF CONCRETE. -- September 23, 1999 Mallory Construction 6122 Dana Circle Magalia, CA. 95954 William and Cleo Hill Assessor Parcel Number: 066-190-004 Building Permit Number: 99-2107 LAND 'OF NATURAL. WEALTH AND BEAUTY BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (530) 538-7541 FAX: (530) 538-2140 This office reviewed the above referenced building plans. Please respond in writing to each comment by creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re -check and approval of this project. Please be sure to include on the resubmittal the engineer's "wet" stamp, signature, registration number and expiration date on all sheets of plans depicting the designed elements and cover sheets of calculations. Provide additional information and/or make revisions to plans, specifications and calculations as follows: /The 2 x 8 ceiling joist at 24" o.c. are overspan. Provide revised detail. • All details from the structural calculations must be shown on the building plans and the plans must include the engineer's "wet" stamp, signature, registration number and expiration date on all sheets of plans depicting the designed elements. 3! Indicate braced wall panel types and locations on the building plans. -� Provide clarification about the garage door header. size. 4 x 14 shown on the construction detail page and 3 '/z x 117/8 Struc-lam shown on the engineering detail. Provide complete foundation detail with the required re -bar shown on the detail. If you wish to discuss any requirements, you may contact me at (530) 538-7541 between the hours of 1:00 p.m. and 4:00 p.m., Monday through Friday. Sincerely, Glenn Gibbons Plans Examiner Page 1 of 1 ,N a+y.:•-..�,--;. �rralw�- -'+" _, ,• -Y'� •ql�«c--+v �,.-:r+.�.. r- Ts'!,_F, n,;jT.,,"-�-'-�83'_'1`.'3Y?��C'..''�i4U"t!�.trG.i.a ;7XS+.r. •.x;�•Ky:d�".FM"?�' W�eF1**�h�`� t 066-19-0-004 .99-2127 PM' HILL', William ' I' 13805. Andover Dr, Magalia -• (HVAC) Del Johnson.l 3 a _.. S. • Z A 7 {L X COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Croville,Xalifornia 95965 • Telephone (530) 538-75�,9- PERMIT NO. (Rev.12/96) APPLICATION AND PERMIT G. Li 17/ r ASSESSOR PARCEL NUMBER r)(010-06-001 96-00 ZO14` , _' BUILDINGPERMIT OWNER TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNERS MAILING DRESS rt n ! ^, , ! ` 1 ( ,Cil CO N[RACTOR' NAME � TE HONE CO TORS MAILING DRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation Is ARCHITECT OR ENGINEER LICENSE NO. —Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS "LING ADDRESS Plan Checking Fee $ BUILDING ADDRESS Energy Plan Checking Fee $ $ PERMIT FEE $ LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE SFX Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each cias water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other U(' /Q.t?11114 -�,�2.,� Describe Work: � I'�ta J\ I- 0 0/h 9 CN6 'P , t Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G W @20.00 PERMIT FEE $ U ELECTRICAL PERMIT Fling Fee 20.00 Main Service A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. No. 3731 g � � License Class C =7b - l 11 'BUILD OWNER ER D CLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors license Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the erformance of the work for which this permit is issued. EVI have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier �,QF/a/7 l'�'.t.+'f,�i/G �Lit?S/�,t/iTtle�A• Main Service 200AWEL TO lOooA 46.00 NEW CONST. OEWNGocc. OR ADDNS. ( ACC. BLDS SO 3.5¢FT. -& ONST- NON.R.. MULTI.OUTLET @7.50 POWER APPARATUS 8 SINGLE OUTLET CIS. EX. OCCU OUTLET OR FIXTURES .00 6AL p I. 0 LNS Ex. Occup. onuXnFrs RES D.OEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Fling Fee 20.00 Heating 12-5 00 74-01) Cooling 7161 Hood 6.50 Ventilation PERMIT FEE $ () Policy Number (The above sections need not be competed ' e permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that f I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. Xr _ Date �' ��" / / _ Signature of Applicant - ❑ Owner ED-Gontractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ cc .,i coNs -TYPE TOTAL FEE $ HAZ. D FE IMP MP „0, FLOOD CDF CDF PARCEL , PD D HD ISSUE ._ This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicat . above for which fees have been paid. nn �} By X.?JXd P Q Date 17 1S-9 Try PERMIT EXPIRES ON 7-/5 -a000 Date Receipt No. R WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT r f, COUNTY OF BUTTE ? BUILDING DIVISION - + DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE /�, Z/ Ale -le-) OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. i - r V�-I ////"^J P! / /yST r Date Inspector 1: REV 10/ 2 = COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-754 PERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT C/ �! �L:i 17/ ASSESSOR PARCEL NUMBER / 9C�^004/ /TE/I.EP(HONE Zo"}yor BUILDINGPERMIT OWNER PJ 1ca 3� SO. FT. OCC. BUILDING VALUATION . OWNER'S MAID DRESS Maa CO CTOR' NAME TE HONE 4 CONiRACTO,gS IU DRESS ^ CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. —Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS Energy Plan Checking Fee $ PERMIT FEE S LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat um water heater 23.00 Water piping 15.00 Each as water heater or vent ( 15.00 TYPE OF WORK New ❑ Addition ❑ `R'emodel ❑ Utilities ❑ Installation ❑ Other Describe Work: ZG a Gas piping system 1 - 5 outlets 15.00,�i7 Buildingsewer 15.00 Mobile Home S G W 920.00 PERMIT FEE $ , n ELECTRICAL PERMIT Fling Fee 20.00 Main Service 2o.A OR IES. 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWER License Class � 249 - /�jLic. No. 0 37 � a 1?a OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the rformance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier eiPiO / i ��, G f,(j,(j ��t//TE,/ Cd - Main Service 200A TO ,000A 46.00 NEW CONST.DWELLING OCCUP. OR ADDNS. ( a ACc. Blas. SO 3.5¢FT: NON-REO.ID. MULTI -OUTLET @7,50 APPARATUS sINGLE ounEr aR. EX. Occup. OUTLET OR FIXTURES 20 @ 1.00 BAL @ .so Ex. Occup. DUT ETS RaID °E 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 f_ PERMIT FEE $ MECHANICAL PERMIT Fling Fee 20.00 Heating 26- O Cooling 6 'j Hood 6.50 Ventilation PERMIT FEE $ Policy Number MLj 1C j (The above sections need not be compFeetedIfthe permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall foqtllvith comply ' h those provisions. j c� tZ� Date"/ F/ a ure of licant - ❑ Owner ®-�eorfGactor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ c .3 TOTAL FEE $ HAZ. D. FE IMP .— FLOOD CDF PARCEL PD HD ISSUE _ This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indica above for which fees have been paid. By Date 9—/-57-9,? PERMIT EXPIRES ON ?-/5 - 07 60o Date Receipt No. .(7U WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT NOTES :r B r 1 :N RESIDENTIAL (066=190-004 99-1173' —` PERMIT NO. =..HILL, William J..-- 13805 .. 13805 Andover Drive, Magalia Contr: O"mer Close on Breezeway and Add partition . SPECIAL CONDITIONS 11 SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER JOB FINALED (Date) Signature CHECKED BY ,/ = OK 0 = Not OK - = Not Applicable = Not Ready MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. 2. Soils; Special MH Support Sketch Gas; MH Test -Demand -Valve -Connector 3. Sewer; Location -Test -Fall -C/O -Concrete 5. 4. Water; Location -Test -Easement Needed (Sketch) Water; MH Test -Regulator -Connector 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 8. 6. Gas; Location -Test -Wrap;-/ /" L'ft. / P Nat. or / /"L"ft./ PLPG Tie Downs -Type -Installation Cert. 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy 12. Permanent Foundation Onlv: License Decal Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs.-Connectors Shthg.-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosure s-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J = OK 0 = Not OK - = Not Applicable = Not Ready RESIDENTIAL (; Date erfloor (Plans) OK except #'s Hangers -Post Caps -Anchors -Connectors Zoning- acks-Easements-Flood-Slope Cling. Joist-Rttr. Ties- Purlin-Roll Brac.-Truss-Shting.-Rfng. , Main; Soils-Elec. Z Ftg. Depth Fireplace Ties or Type A Flue -Fireplace Throat Clearance 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Death Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 5. Stemwalls, Main; Steel-Blockouts-Wrapped Garage Fire Protection Framing 6. Stemwalls, Garage; Steel-Blockouts-Wrapped Property Line Firewall & Openings 6a. Hold Downs and Special Anchors Ext. Doors -One T -Check Garage 3rd Story, 2 Exits 7. Slab, Steel -Wrapped Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 8. Piers -Fireplace Ftg.-Steel Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test Siding -Nailing Veneer 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 11. Water Pipe; Test -Anchors -Regulator -Service Test Glazing Area -Glass Protection -Skylights -Plastic 12. Electric Underground Shear Walls; Nailing -Bolts 13. Plenums & Ducts; Clearance -Material -Support -Ins. Brace Interior/Exterior Wall Panels 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies Insulation -Walls -Ceilings 15. Access & Ventilation Infiltration -Walls -Windows 16. Insulation Date Date Date Card B-1 Date Carc B-1 Date Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s Ext. Steps -Door & Sidelight Protection -Landings 17. Water Htr.; Vent -Access -Combustion Air Baffle Smoke Detector 18. Water Pipe; Test & Anchor -Nail Protection Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor -Ducts -Mach. Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection Bedroom Exiting 20. Shower Pan; Test, First Floor -Tub Access G.F.I. & Bath Fixtures & Tub Access -Spa 21. Test Tub & Shower, Second Floor -Tub Access Elec. Trim & Subpanel, Breaker Sizes & Labels 22. Gas Pipe; Sixe & Anchors Stairs & Rails 70. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s Elec. Outlets & Receptacles at Kit. Counter 23. Fixture & Transformer Clearance -Ins. Protection Garage Fire Door; Swing -Landing -Closure 24. Elec. Receptacles Spacing -Lights & Switches at Doors A.C. Duct in Garage -Damper 25. Size Boxes & No. of Conductors Stapled Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 26. Romex Installed Close to Edge of Studs & C.J. Plb., Elec. & Mech. Equip. Listed for Location 27. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water Elec. Receptacles in Garage (FFI.)-Romex Protection 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI Insulation -Foam -Looked in Attic 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or Al Guard Rails & Deck Construction -Post Caps 30. Range Circle / / ga Cu or Al -Oven Circ. / / ga Cu or At Insulated Neutral ❑ Yes O No Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth 31. Service -Riser Conductors & Ground Main Disconnect Clearance Looked under Floor ❑ Yes 32. Equip. Clearances Panels-Motors-Mech. Equip. Following Instld./Drive ❑ Yes ❑ No/Walks ❑ Yes ❑ No/Planters ❑ Yes ❑ No 33. Clothes Closet Light -Shower Light -Spa Light Stucco Brown -Finish 34. Smoke Detector A.C. Unit Disconnect, Electrical -Plumbing 85. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s Ventilation Throughout House 35. A.C. Ducts Insulation & Support Glass Protection 36. Vent Fan, Exhaust above insulation Corrections from Previous Inspections 37. Condensate Drain & Overflow, Size & Grade Gas Test -Meters Tagged, Gas -Electric 38. Furnace -Vent Access -Comb. Air -Return Air Vent 115 outlet Water & Sewer Connected -C/O to Grade -HD Approval 39. Attic Access & Platform if Furnace in Attic Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card 3-1 Date Card B-1 Date Card 3-1 Date FRAMING (Permit) OK except #'s Date 40. Sits Proper Materials & Anchors Comments at Final: 41. Walls Studs -Nailing Spacing & Braces- Plates- Sounc 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing jingle & Duplex) Date FRAMING (Continued) 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rttr. Ties- Purlin-Roll Brac.-Truss-Shting.-Rfng. 48. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One T -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior/Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext. Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor -Ducts -Mach. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance 73. Elec. Outlets & Receptacles at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 77. Plb., Elec. & Mech. Equip. Listed for Location 78. Elec. Receptacles in Garage (FFI.)-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard Rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 82. Following Instld./Drive ❑ Yes ❑ No/Walks ❑ Yes ❑ No/Planters ❑ Yes ❑ No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throughout House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: .rr ` s. COUNTY OF BUTTE - DEPARTAAENT OF DEVELOPMENT SERVICES - BUILDING D ISION 7 County Center Drive • Oroville, CU!ifornia 95965 • Telephone (530) 53 PERMIT NO. (Rev.12/,96) ; APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER 066-190-040 ZONING BUILDING PERMIT OWNER HILL, WILLIAM J. TES _0451 SO. FT. OCC. BUILDING VALUATION 9 11–R 9478200-9 OWNERS MAILING ADDRESS 13805 ANDOVER DRIVE, MAGALIA 95954 _ R 8236.9 CONTRACTOR'S NAME OWNER TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation Is 16.714, ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 180,017 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checkin Fee $ BUILDING ADDRESS 13805 ANDOVER DRIVE MA AL•IA Energy Pian Checking Fee $ PERMIT FEE $ LOT No. 3 ��1�ANTISEMPINES COUNTRY CLUB EST PARCEL MAP 66-19-04 PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ]] Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK New ❑ Addition EK Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: CLOSE IN BREEZEWAY AND ADD A PARTITION Gas piping stem 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I WF— @20.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 0OR UE Main Service . "OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.A License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law r the following reason: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation hof one hundred dollars ($100) or less.) 9 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith c ply with thos provi ' ns. / / p X 1Date /� / " / Signature of Ap ant - Owner ❑ Contractor ❑ Agent An OSHA per Is required for excavations over 60" deep and dem Iti or construction of structures ver 3 stories in height. I Main Service zoOA TO ,000A 46.00 NEW CONST. DWELLING OCCUP. SO OR ( a ACC. BLDS. 3.5,saI S-27 CNS. T. NO"ON•ROESID MULTI.OUTLET 97,50 PSINGE OUTLET OWERLAPPARATUCIR.S 20Q1�0° EX. OCCU OUTLET GRFaTUREs BAL Q .50 Ex. Occup. OFUTrED s RM DE,L 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ 35.27 MECHANICAL PERMIT Fling Fee 20.00 Heating DUCTS 15.00 Cooling Hood 6.50 Ventilation PERMIT FEE $ 35.00 Mobile Home Installation Fee $ Energy Inspection Fee $ 4.6.00 OCC CONST. TYPE 573.27 TOT L FEE $ HAz. D. IM OD CDF PARC HD SUE This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have By PERMIT EXPIRES ON the applicable provisions Resolutions to do work been paid. rIf.� Date J l - (} to Receipt No. 2 52O 527.27 . WHITE-D.D.S.-B.D. CANARY -ASSES R PIN -INSPE OR G DENROD-APPLICANT II -y:�=-.+;d �;i�4%li..% �.�. ` .�r�"�ti+-i1t�'k�i�%�'�S��ii(C7!!�'kt�:if••t+v">r:F�i�G1....y:'�4�.�r•w�:f�......:� . � • r COUNTY OF BUTTE - DEPARTMENTS` ' VELOPMENT SER ,VICES - BUI DIVISION, 7 COUNTY CENTER DRIVE - OROV L; CALIFORNIA 95965 - TELEPHO 30) j41 z PERMIT APPLICATION DATA SHEET OWNER: /1-101-- . t ASSESSOR PARCEL: _A � 1 3 D -- /0C,C Proposed ding Use:e 1 wilding Inspector:Or Dater — y"C At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: Date Received By ❑ 1. All items have been submitted -------------------------------------------------------------------------------------- 02. Plot plans, 3/4 sets, signed by the preparer of plans. ------------------------------------------------- --------- 113. Complete plans, 3/4 sets, signed by the preparer of plans.------------------------------------------------------ 64. ------------------------------------------= --- ❑4. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. -------- - ❑5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------ + 06. Energy Design Compliance and supporting documentation. ----------------------------------------------------- 117. --------------------------------------------------- ❑7. Statement of Intent for Non -Heated and A/C Buildings. -------------------------== 1------------------------ --- 0 .❑ 8, Hazardous Material Form.---------------------=-------------------------------------------------------------------- 9. Manufactured L/ Home data and installation instructions including Tie Down Specifications.------------------ Al'C� " ` ees of $ T(P • --------- 2L -------------------------------------------------------------------------- .. 1111. Impact fees as shown on the attached schedule.`-------------------------------------------------------------- ❑ 12. California Department of Forestry plana roval/fe`es.------------------------------------------------------ ppT.. ❑ 13. Eledd elevation.certificate.---------------------- =! --= V`E 4. Sanitation and plot plan approvalCHealth Department. ------------------------------------------- 674 ' 1115. City of Chico plumbing permit.--------------==-------------=------------------------------------------------------ y ❑ 16. Plot plan and business license approval fromthe City of Biggs. ---------------------------------------------- ❑ 17. Planning approval for (A) Use: 00 - (B) Parking: -------------------------- —`3 — ❑ 18. Contact Land Development about ❑ Improvements, ❑ Drainage, 0 Legal Parcel. ----------------- 1:119. ,Encroachment Permit for driveway (construction approval prig t occupancy). --------------------- 020, P e -inspection for required. Request to Building Inspector on ❑21. Contractor's license information. (Number, Name Style, Classification). ----------------------------- El 22. Workers' Compensation carrier and policy number •. -------------------- 1123. Owner -Builder Verification (Given to owner ❑, Mailed to owner ❑). 024. Letter of signature authorization. ------------------------------------------ 025. Recorded copy of Agricultural Acknowledgment Statement. ----------- ❑26. Letter of intent on building use. -------------------------------------------- 027. Manufactured Home utility clearance. --------------------- =-------------- ❑28. Existing violations and/or expired permits. -------------------------------- 0 29. ❑433 A, ❑Grant Deed, ❑ M.H. Title, ❑ Check to H.C.D $ 030. Other: When you issue the permit, proc s as follows ❑ Mail to owner, ❑Mail to contractor. , �lephone C5 7 3 " o � and hold for pickup at office. ❑ Deliver with""spector. Applic .. ~ Date: eo / 7Z Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, ❑ Air Pollution Date: By: , Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ O er: Date: By: } 1. Index permit application for the above items numbered: ❑ Plan Check List 2. Additional items required: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building :Division counter, by Date: Contractor, designer, owner, was advised ob4 y y�g ire f, � ❑ phone, ❑ mail, 13 Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ B ildin Sion ounter, by Date: Plans reviewed by: Date: Plans approved by: Date: 6 Sets of plans on hold in ❑ Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: n--_ice:--^=--`-`-- /i-73 TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance E.H. USE ONLY Plot Pl Atteched_E� Floor Plan Attac a Sent to B.D. I toj os, Aqkver Dr. ()(196 - 1,90 -004 - Owner 90 -004 - Owner Location f AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for Other Ay0 QFACes iter �a4a"ue-d r�fam,y.• Hold final for: .Final clearance O.K. for: NOTE: / 2EYs Environmental Health Specialist 8/96 4 -99!9 Date 1 COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 TELEPHONE (916) 538-7541 . 1 �[ SCHEDULE OF FEES DUE OWNER JC PROPOSED BUILDING USE G 1. BUILDING PERMIT FEES -- Balance Due ................ $ -- Additional Fees Due ...... ' ..... $ -- Additional Fees Due ........... $ -- Revised Plan Checking Fee .:..... $ 2. SCHOOL DISTRICT FEES PA—XJ+-P I t (paid at District Office) 3. SHERIFF FEES (paid at Building Division) Residential ........ x $360:00 = $ Units Commercial (sq.ft.)... x $0.03 = $ Sq.Ft. 4. URBAN AREA FEES (paid at Building Division) Residential (per unit) . X_ _ $ #Units Amt. Commercial (sq.ft.) .. x =$ Sq.Ft. Amt. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES 10.00 (paid at Building Division) FIRE INSPECTION' AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER A.P. #6 6 —1 F0 61, DATE & -- ( RECEIPT # DATE REC At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICANT DATE 6�,::,� Pursuant to Government Cod bion 66020, you are hereby notified.that items 2,3,4,5,6,8,9, avid 10 above may have been imposed on your project. You have 90 dayspm the date of approval of the project oe,from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original -Building Div. 2nd Copy - Applicant 3rd Copy - Owner (Rev. 2/97) i .ir-.+ v"+- TAt`s'•!i- ♦ �'N. 'R•-1,.- R �.7%i�i+"i1.• '� .r�� + .i� COU, N'I OF BUTTE- �,/ a; DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING�IBVISIO �. 7 COUNTY CENTER DRIVE, OROVILLE•CA 95965 TELEPHONE (916) 538-7541 t - ' SCHEDULE OF FEES DUE OWNER (1 !�`� w►; (r / �- L A.P. #66 PROPOSED BUILDING USE~� G G DATE CO 1. BUILDING PERMIT FEES -- Balance Due ............ $ -- Additional Fees Due ........... $ -- Additional Fees Due ............ $ -- Revised Plan Checking Fee ........ $ / 2. SCHOOL DISTRICT FEES P;k—X—" 1 C C (paid at District Office) 3. SHERIFF FEES (paid at Building Division) Residential ..... x $360.00 = $ Units h t Commercial (sq.ft.)... x $0.03 = $_ ` Sq. Ft. 4. URBAN AREA FEES (paid at Building Division) Residential (per unit) . _ (--,, Vx 1 = $ #Units Amt. Commercial (sq.ft.) .. x =$ Sq.Ft. Amt. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) �STtFIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) . .8. ATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at -Building Division) 10. OTHER RECEIPT # DATE REC At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking. process. APPLICANT DATE Pursuant to Government Code�L�on 66020, you are hereby notifedft1iat items 2,3,4;5,6,8,9, and 10 above may have been imposed on your project. You have 90 days dm the date of approval of the project ortfrom the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). _70 ye'7 K,, e Original -Building Div. 2nd Copy -Applicant 3rd Copy'- Owner (Rev. 2/97) r � f ,�-✓ ,� ,r�" .,'„ "�o• � '` '"': % v;r '/. .t,.-r•,ra;� � ..� _ v;/• ... , -sjj �'^.rr r' ' j � .L v . Lv CONT;Y OF BUTTE' e_ ; ••.,s,, > DEPARTMENT OF DEVELOPMENT SERVICES - BUILDINGDIVISION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 TELEPHONE (916) 538-7541 �,j SCHEDULE OF RECEIPT OF FEES i OWNER DJ( t ,;! T J �. A.P. 066 4` `�l�" D PROPOSED BUILDING USE DATE CP - 1. P - 1. BUILDING PERMIT_ FEES -- Balance Due ................ $ -- Additional Fees Due ............ $ -- Additional Fees Due ........... $ -- Revised Plan Checking -Fee ....... $ 2. SCHOOL DISTRICT FEES (paid at District Office) 3. SHERIFF FEES (paid at Building Division) Residential ........ x $360.00 = $ Units Commercial (sq. ft.). x $0.03 = $ Sq.Ft. 4. URBAN AREA FEES (paid at Building Division) Residential (per unit) . -1 L/x) _ $ #Units Amt. f Commercial (sq.ft.) .. x =$ Sq. Ft. Arrit. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES $ 10.00'(paid at Building Division) FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. V'VATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER RECEIPT N ' DATE REC 0 At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. / APPLICANT t O �-'� _ DATE � ods • • -- � of Pursuant to Government Code a tion 66020, you are hereby niified)th items 2,3,4,5,6,8,9, and 10 above may have been imposed on your project. You have 90 days .dm the date of approval of the projector from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original -Building Div. 2nd Copy -Applicant 3rd Copy_ - Owner :L (Rev. 2/97) e. f OWNER -BUILDER VERIFICATION Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature; Please complete and return this information at your earliest opportunity to avoid unnecessary delay~ in processing and issuing your building permit. No building permit will be issued until $dg verification is received. ; :. ,3 1. I personally plan to provide the ajor, labor and materials for construction of the proposed property improvement: YES NO a 2. I HAVE e HAVE NOT O signed an application for a building permit for the proposed . 3. I have contracted with the following person (firm) to provide the proposed Construction': ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 4. I plan to provide portions of this work, but I have hired the following person to` eoot+dio�r; supervise, and provide the major work: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. ' 5. I will provide some of the work but I have contracted (hired) the following persons to prpNide the work indicated: NAME ADDRESS PHONE TYPE OF WORK SIGNED: PROPERTYOWNER: A �A t L_L_ SOCIAL SECURITY NUMBER: © DATE: NOTE: This Owner -Builder Verification is required by Section 19831 and 19832 of the• California Health and Safety Code. This verification must he completed iwd returned to our office before we are permitted to issue the permit. OVER OWNER BUILDER INFORMATION 1 Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of property . improvements specified. For your protection, you should be aware that as "owner-buildee, you are the responsible parry ofjecord on such a permit.. Building permits are not required to be signed by property, owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should: be aware of the following information for your benefit and protection: . ♦ If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $300 or more for the entire project, and such persons are not licensed as contractors or subcontractors. then you may be an employer. ♦ If you are an employer, you must register with the State and Federal Governments as an employer and you -am subject to several obligations including state and federal income tax withholding, federal social security.taxes, workers compensation insurance, disability insurance costs, and unemployment compensation contributions... ♦ There may be financial risks for you if you do not carry out these obligations, and these risks are especially,serious with respect to worker's compensation insurance. ' ♦ For more specific information about your obligations under Federal Law, contract the Internal Revenue Service. (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under'limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "owner builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractprs may be obtained by contracting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA. 95814. - Please complete the "Owner Builder Verification" pn the reverse side of this form so that we can confirm that you.. are aware of these matters. The building permit will not be issued until the verification is returned. I4Mg!er, ly, '�1 C. ViLa, C.B.O. Building Inspection NOTE: This Owner -Builder Information is required by Section 19830 of the California Health and Safety Code - OVER COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 PER �Io. (Rev. 12/90) APPLICATION AND PERMIT A42060APARMIJU OM &6 _) —d4 notaFa BUILDING PERMIT y , I S 1 L, t_"D�F.s" SO. FT. I OCC. BUILDING VALUATION ow►ers MAuw ADDRESS r— A _ n A s OOMMAr.• WO K%W -T- CONrRACTOR7 MOWU G AOORlee M � OOMTIN)CnOm LEmot 1--j C, *—i uwors MMUHO ADOFEle AACHRECr OR ENOIHEER C9t.l cf- APZWECr OR 04MEMI MALOO ADD{ = �N a �C.2ApIS��IN C6uNT -Ca+13-LS gT _ rvl 3 U)TND. susotval0lnwue ►ARc9L MAP USEOFSTRUCTURE SF f" Duplex 0 Wbilehome O Other syscsv TYPE OF WORK New 0 Addition Me"Remodei O WGBes 0 Insulation 0 Other C3 Describe Work:�'t Se- r .N Fireplace L �:90 tiAL !0 Ex. OCCU FMD �W' ovnrm aro. a Total Valuation Is Filing Fee S 20.00 Permit Fee = Q Plan Checkina Fee E t coo Energy Plan Checking Fee S �3 S PERMIT FEE PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.00 Solar or heat p mp water heater23.00 Water piping 15.00 Each as water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G W (920.00 PERMIT FEE _ ELECTRICAL PERMIT -Filing Fee 20.00 Main Service = oon t 23.00 Mein Service ( aooA TO 160 ) 46.00 .50 Ex. Occup. otm00 aT OR FKFUREs L �:90 tiAL !0 Ex. OCCU FMD �W' ovnrm aro. a 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Wsc. Wiring 23.00 PERMIT FEE = S �Z MECHANICAL PERMIT Fling Fee 20.00 Heatina %N to f ?' i 8.50 Ventilation PERMIT FEt S UCS Mobile Home Installation Fee $ Energy Inspection Fee S occ OWST• TYPE TOTAL FEE $ Z KAZ 10. FEES I WP I P.000 I COi I PAFCEl I PD I PO I ISSUE This permit Is hereby Issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date ReceiptNo._ PERMIT EXPIRES ON WHITE•0.0.8.•8.0.. Ana 0wr_iuco0r Tna ran. neuan0-APPLICANT _ ". "1.�ri,iv`.:�i.r.y,�� p�.�r.��['vn-M.�"tit.�•+..,r,�,i'^"'r"f�..n✓r�vYr ws Yrs'Y4��+Yn+��tit%K"w^�,,,"✓��'`i."Z%,w-v+yw-"��++,'k'•�t�k�^�y�.,"...d'..wi.,.r.+.• ..�....�� '�T-�:— .. •fir BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Building) School District 1 L r e Building Department No. Q rs A.P. Number M D�W t0 _Oy1c, Jurisdiction: City County Property Ciwner e �/V II Q M f Property Location/Address Subdivision s Residential Development Commercial/Industrial Building Department Repreee Distri Identification No. �Os-A %IStreet Address) l - A It An d o ver- ber . bX J Lot No. ................................................................................................................: ' 4 Sq. Footage.: � 3 �Y No of Living Mobile Home AdddioN *Supplemental to (Group.R) Units Installation Conversion Permit # '(No foundation inspection): i................................................................................................................... New Addition Floor Plans reviewed by School District f2 .,Sq. -Footage (Including Exterior Roofed Areas) C�r15-99 Date School District certifies that j (Applicant) State) has complied with the requirements of Resolution No. representing square feet strict Representative Paid by Check # it /TT Remarks: (Phone Number) (Zip Code) by payment of $ . AB 292fi S FULL MITItisATION : y A7r/—.. Date Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 660201a), within 90 days from the date fees are paid. Failure to submit a timely written protest willprohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act ICEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xis (10/98)dmm ri f.J C-- k Q t-4 7�eu I N Te � >,t,n� t �� I Sct,a� 1 /S ,I =- 1- ®)) V6a,s\Da,,Nce o F. 4 GLae� 4%,, \380's �-Oova'R 'TDc�� vp,0- AG�t.tp� CA 9 9 I� on the job ®t a!i nab® cin` t,• m �changes or atter gri"Dn Permission from the WC � Dj NOTE, ---&I Materiois & Accordance w;th awcn�r ..d r.. '� 11 2 and it is cenl ' ;ant on So,t: �-`Good Practi i < �lpa SPdclffedi i'�b in �C��tvS►oN. pINC��l2S pST �z t5t'j 7�121112-1 ,jUT-E COUNT f ,:EOLDING DrEPARTMEW Ap e VE q -11n> 2535.,=79B,P,E,M :PEFQIT NO. PERMIT EXPIRES :OWNER Bruce Roethl.er CONTR. owner -�40CATION (A.P. 66-19-4 ) 380 Andover Dr., lot 12, PPCC#3, Magalia i 4. n e Ck L,y t ' r. Temp. Power Pole CallYJ&E Temp. Eerv.Call&E D TempGas Serv. lie PG&E u - B_ FIN' ED / s (Date) (Signal(re) k COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS ti BUILDING INSPECTION RECORD BUIL15ING BUILDING (Cont'd) Setback -/-J- Firewall Forms •;- 7 dF 4W Parapets Main Bldg. Restroom Finish Footings Windows - Stemwal IIdin Elec. Continuity Slab Roof Sheathing Piers - Roofing Garage Fdn. Vents , Footings ® Stemwal) G Ga Vents �---�� sulatl- Slab -- Carport Footings Prov. for ysically handicapped Conformance of ex. structure Slab In (]- Patio FIREPLACE Masonry Walls I Throat �lMReinf. Steel 6 X -75r &4j Ina /,0- ?/- Mesh / Mesh Scratch Brown Finish Test Final MECHAP Heating Z--/2--;79 Cooling - Ducts 9 10 Ventilation / 7f:> PLUMBING Soil Pipin 1st Floor - ,p - 2nd Floor S 3rd Floor Sewer Fixtures Water Htr. 40 Heaters Appliances '41 10 Gas Piping & Test Iv 0' 2Can .Gas t o Final ELECTRICAL Rom - h 40 wSubpanels ,0- - % f - -' 7 6— Gird. Fault Prot. -% Service Temp. Pole q k DoorCloser /� T 9 � Final y—/7-,:17 (�' Final/p .-,y`�� -7 ("IN MOBILEHOME UTILITIES ------------------ Elec. Service Elec. Pedestal Water Piping Sewer Gas Piping BI E OME INSTALLATION - - - - - - - - - - - - - - Support Elec. Continuity Water Piping Drainage Gas Piping DATE REMARKS OR • • / , I Ir 7111f -7q i l *0 akc/, fvt0000r ev 196 'T- r 1--i;7f >r �+- a-ep 9 ( 'TNOTE: An enrCy must be made on tis Aa h time you visit the job site.) ell- 011e At ¢.3 redr�Js . lea f Ole Ole ZA c,- ©a cep k/ c e /,1 jr i/ aL%'��� 0 iii AAC,C- r,� 3%� �9 G�NIDdZ D/<C � Oil �p �/j✓r ,5��€'llirG£ dvlt ~ Iva s RESIDENTIAL ENERGY CONSERVATION STANDARDS CONSTRUCTION COMPLIANCE CERTIFICATE THIS IS TO CERTIFY THAT ENERGY CONSERVATION REQUIREMENTS HAVE BEEN INSTALLED IN CONFORMANCE WITH CURRENT ENERGY CONSERVATION REGULATIONS AT (location) BUILDING PERMIT NO. :2f; 3s"% Cf A. -'P. NO. /o (p Jl �/ — 01/ THE FOLLOWING HAVE BEEN INSTALLED AS PER APPROVED PLANS: (Check each item or write N/A if not applicable) 1 INSULATION: Slab Edge. IVA Fdn.'Walls JA Floors Walls 1 no Ceiling/Roof IA_oD Ducts '--- Circulating Pipes +-- APPROVED HEATER -� APPROVED WTR.HTR. GLAZING: Single Glazed Special (Insulated) CERT. & LABELED WDS. & SLIDING DRS. Ll WEATHERSTRIPPED DRS. l BACK DAMPERED FANS INTERMITTENT IGNITION DEVICES CERT. APPLIANCES I DECLARE THAT ALL REQUIRED ITEMS AS NOTED ABOVE HAVE BEEN INSTALLED IN ACCORDANCE WITH THE ENERGY CONSERVATION REQUIREMENTS AND AGREE TO THE COMPLETENESS OF THIS CERTIFICATE AS SUBMITTED. Insulation Applicator Name 1u -,)U Lo A,"1'Ml) t•� Signature of (please print) Insulation Applicator_ State Contractors License -No. 7�t �� (o General'Contractor/Owner Name Signature of ( ease�print) �,.r� General Contractor/Owner i i�d .�J Date c.Qe State Contractors License No. 07 THIS CERTIFICATE MUST BE ON FILE WITH THE BUILDING DEPARTMENT PRIOR TO REQUESTING FINAL INSPECTION AND SHALL BE POSTED IN A CONSPICUOUS LOCATION WITHIN THE DWELLING. COUNTY OF BUTTE — -DEPARTMENT OF PUBLIC WORKS 7 County Centel Drive Oroville, California 95965 " Telephone: 534-4541 APPLICATION AND PERMIT All authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. X Dates y 7� ignature of Per tee or Art Re eipt No. White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTO PUBLIC WORKS B / Ot/Date,���7�%/� Building permit expires Date BUILDING Owner SQ. FT. OCC. BUILDING VALUA I N Mailing Address�9 p S' p CJA tr_L -- 12�i 3 /2. 8 Z Tel apho��i7 J /� 3 LSD✓>O Contractor Mailing Address S w/1ilLLi.. , Fireplace Total Valuation � 404 QHS£ Te ephone No. ., tfr%8 Permit Fee Z47- -- Building Address 's _ N��%/� �" Plan Checking Fee&/or Penalty Permit Fee /4 Z _T4_27__ � PLUMBING No. @ FEE PERMIT FILING FEE $3.00 3,0 Each Trap 1.50 2.pa IR Repair drainage or vent piping 1.50 A. P. No. _ 1 Y® >6 Xonin;g & anning Water piping 1.50 /„S'p Each gas water heater or vent 1.50 F Sani(Do' n Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA Parking Plans rcel Declaration Parcel p 60' R/W Im rovem s p Each additional outlet .30 Building sewer 5.00 Bldg. Plans R Parcel Approvol Plans pproval Lawn sprinkler system 2.00 NEW ADDITION ❑ UTILITIES ❑ OTHER ❑ Permit Fee $ is ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 e> Main service 100 AMP OR00V OR L LESS5.00 Single Family Ef Duplex ❑ Mobil Home ❑ Others ❑ Main service EA. AOD'L 100 AMP 2.50 Main service OVER 100 AMP eoovOR LESS 25.00 - Main service EA. ADD'L 100 AMP 1.00 NEW CONST. DW OCCUP. Y OR ADDNS. ( A S. 22 sq ft LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: i��(� �� �5 �'-�(Z ���S.1C2►. NEW CONSTR.MULTI-OUTLET NID BRANCH CIRCUITS 12.50eaCONTRACTORS NEW CONSTR. /POWER APPARATUS B NON.RESID. %SINGLE OUTLET CIR. EX.00CUqOUTLETS OR FIXTIiRES1 50@250BAL@1 FIXED APPLNS. OR EX. Occup. OUTLETS (RESID.) EA2.00 Temporary service 10.00 Mobile Home Facilities 15.00 �p r License No. 3139(3 Classification J 1 Misc. Wiring 6.25 ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ 39,`to $:G MECHANICAL No. @ FEE WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ®I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. PERMIT FILING FEE $3.00 7,oD Heating©All ro 41R41 He9)x U Cooling 1110 c i D Ventilation Hood 2.00 g,OD Permit Fee $ / 04 $ 73 I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Land Development Fee $ TOTAL PERMIT FEE $ ! authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. X Dates y 7� ignature of Per tee or Art Re eipt No. White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTO PUBLIC WORKS B / Ot/Date,���7�%/� Building permit expires Date RESIDENTIAL PLAN CHECKING GUIDE / (S.F., DUPLEX, & MISC. ONLY) Bldg. A.P. A. GENERAL Zoning requirements.(sideyards and parking).' Valuation. �.� Signature by R.C.E. or Architect ( if 'required) . B. PLOT PLAN Complete parcel size and dimensions. Setbackq, sideyards, easements, etc. 'Other buildings or structures. Grading, fills, drainage. - Permit # C. FLOOR PLAN •4m.—Camplete to scale plan with dimensions. 2==�..Required windows for light and ventilation (Sec. 1405). Required windows for second exit (Sec. 1404). —_4 Allowable glazing for energy requirements (20% max. per.State law). '') Human Impact glass (Sec. 5406). Required room sizes, ceiling heights (Sec. 1407). G.F.C.I.'s in baths and exterior outlets (Sec. 210-8). Light fixtures, switches, receptacles, and exterior receptacles for maintenance of mechanical equipment. w--9. -Locations of water heater, heating & cooling equipment, other electrical or gas equipment, an p um ing fixtures. Garage firewall, door size, and closer (Sec. 503(d)(4)). ` '?TT --'l - 3'0" exterior exit door (Sec. 3303d).. Fireplace location. Smoke detectors detectors (Sec. 1413). D. STRUCTURAL DETAILS 'Foundation plan complete enough to construct building. —2-" Floor construction details complete enough to construct building. .g!—Elevations and wall construction details complete enough to construct building. An" Roof construction details complete enough to construct building. ,%�.'-Fireplace construction details and calcs if over one-story in height. 6-- Sufficient data and details to satisfy energy insulation'requirements (State law). E. MISCELLANEOUS ITEMS TO LOOK OUT FOR CCX plywood on exposed locations and overhangs. Stairway details (Sec. 3305). Guardrail details (Sec. 1716). -Brick or stone veneer (Chapter 30). xterior plaster - weep screeds (Sec. 4706 & 4708). .fes roper roof pitch for roof covering (Chapter 32). Rafter ties or bearing ridge beam., garage door or porch header sizes. ..p9—. Adequate bracing. d Living area over garage - complete. 1 -hour separation required including supporting � � el �.ls and posts, etc. Two (2) exits on three-story dwellings (Sec. 3302). PRINTED N 1000H -, E OCLEARPRIN T i � I 3 PRINTED N 1000H -, E OCLEARPRIN T i � I r^ O