HomeMy WebLinkAbout068-400-0150168=3'4t -t23 0b6-Yoc -as 08
KEITH, ROBERT INALE
k
2 ROSEMEL CT. OROVI LE
CONT: OWNER
NEW SF
'ROTESRESIDENTIAL
— — 01-1708 1
# KEITH, ROBERT t
12 ROSEMEL CT. OROVILLE
a< CONT: OWNER
' 1 NEW SF
.'m
�,, , • SPECIAL CONDITIONS
' CHECKED
-BY
SRA .
FLOOD CERTIFICATE REQ.
FIRE SPRINKLERS REQ.
SPECIAL INSPECTION ITEMS
VERIFY
USE PERMIT CONDITIONS
SUB—STANDARD HOUSING LETTER
OFFICE COPY
Address
GAS
Meter by -Z Date0
-1
EL
Me
Ce 7 B
.v ELECTRIC
Meter By - Date
1
JOB FINALED (Date) d
Signature
fit`.'
`'= OK
0 = Not OK
= Not Applicable
= Not Ready
MOBILE HOMES
Date MOBILE HOME UTILITIES (Plans) OK except tf's
1.
Zoning Requirements -Setbacks -Easements
2.
Soils; Special MH Support Sketch
3.
Sewer; Location -Test -Fall -C/O -Concrete
4-.
Water; Location -Test -Easement Needed (Sketch)
5.
Electricity; Location-Clearances-Grnd-/ /Amp -Concrete
6.
Gas; Location -Test -Wrap;-/ /" L'ft.
/ /'Nat. or / /"L"ft./ PLPG
7.
Well Clearance & Disconnect
8.-
Utility Clearance
Date Card B-1 Date Card B-1
Date Card B-1 . Date Card B-1
MISCELLANEOUS
Date DECKS, COVERS, CARPORTS GARAGES (Plans) OK except #'s
1.
Date
Card B-1 Date Card B-1
Date
Card B-1 Date 'Card B-1 ) '.117
Date MOBILE HOME INSTALLATION (Plans) OK except #s
1.
Zoning Requirements -Setbacks -Easements
2.
Footings; Size -Spacing -Marriage Line -
3.
Gas; MH Test -Demand -Valve -Connector
4.
Electricity; MH Test -Crossovers -Breakers -Clearances
.5.
Drain; MH Test -Fall -Flex Connector
6. -Water; MH Test -Regulator -Connector
7:
Water and Sewer Connected -C/O to Grade -HD Approval
8.
Gas and Electricity Tagged,
9.
Tie Downs -Type -Installation Cert.
10.
Exits; Insp.-Sketch
11..
Cert. of Occupancy
12.
Permanent Foundation Only; License Decal
Date Card B-1 Date Card B-1
Date Card B-1 . Date Card B-1
MISCELLANEOUS
Date DECKS, COVERS, CARPORTS GARAGES (Plans) OK except #'s
1.
Zoning Requirements -Setbacks -Easements
2.
Footings; Soils -Size -Depth -Spacing -Connectors -Steel
3.
Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails
4.
Wood Awn.; Posts- Bea ms- Rftrs.-Connectors .
Shthg.-Frg-Bracing
5.
Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures
6.
Carports; Windows -Doors
7.
Electric
8.
Frmg.; Sills -Anchors- Studs- Rftrs-Trusses
9.
Siding; Nailing -Veneer -Stucco -Mesh
10.
Roof; Shthg-Roofing
11.
Ext.; Steps -Doors -Landings
12.
Braced Wall Panels
10. Plumb.; Cir. Test -Water Supply Test
Date
Card B-1 Date Card B-1
Date
Card B-1 Date Card B-1
Date
FINAL (Plans) OK except #'s
1. Setbacks -Easements
2. Soils; Compaction -Structure Stability
3. Pool Structure; Steel -Connections -Thickness
Dead Men -Lining, .
4. Elec.; Receptacles and Lighting, Distance-GFI
5. Elec.; Pool Lighting; 15 Volts-GFI '
6. Elec.; Enclosures; Conduit Entries -Terminals -Listed
7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater
8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg.
Boxes- Enclosures- Panelboards-Ins. to Main in Conduit
9. Health Department Approval
10. Plumb.; Cir. Test -Water Supply Test
11. Light Niche
Date
Card B-1 Date Card B-1
Date
Card B-1 Date Card B-1
- t
y
I
J = OK
0 = Not OK
- = Not Applicable
= Not Ready
Date Underfloor (Plans) OK except
oning-Setbacks- Ease ments-Flood- Slope
.tg_ Main; Soils-Elec. Grnd.-/ 21�Ftg. Depth
Jr-Ftg., Garage; Soils-Steel-Ele . Grn Z�Ftg. Depth
4. Ftg., Porches & Decks; Soils -Steel-/ P' Ftg. Depth
5. Stemwalls; Main; Steel-Blockouts-Wrapped
6. Stemwalls, Garage; Steel-Blockouts-Wrapped
6a. Hold Downs and Special Anchors
(0/5 T/ 7. Slab, Steel -Wrapped
8. Piers- ireplace Ftg.-Steel
-g� W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test
10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test
11. Water Pipe; Test -Anchors -Regulator -Service Test
12. Electric Underground
13. Plenums & Ducts; Clearance -Material -Support -Ins.
14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies
` 15. Access & Ventilation
RESIDENTIAL (Single & Duplex)
#'s I Date
16. Insulation
Cate D( Card B-1 Date Card B-1
Dat Card B-1 Date Card B-1
Date LUMBI G (Permit) OK except #'s
Wat Htr.; Vent -Access -Combustion Air Baffle
1 Pipe; Test & Anchor -Nail Pr
D.W.V.; Test Fittings & Ancho -Nail
Q hower an; Test, First Floor -Tub Access
est Tub & Shower, Second Floor -Tub Access
as Pipe; Sixe & Anchors
Date Card B-1 Date Card B-1
Date ^ Card B-1 Date Card B-1
Date ELE TRICAL (Permit) OK except #'s
ixture & Transformer Clearance -Ins. Protection
/2 lei Receptacles Spacing -Lights & Switches at Doors
Size Boxes & No. of Conductors Stapled
•26. om Installed Close to Edge of Studs & C.J.
qui , Ground made up w/Mech Fasteners -Bond s & Water
2 Appliance Circuits in Kitchen & Conductor Size GFI
29. 9ebited t�S'hM , / g Cu or AI-A.C. Wire Size /j_ /gait'? r At
30. Range Circle / / g ven Circ. / / ga Cu or At
Insulated Neutral es C) No
31. S & Ground Main Disconnect
_ Equip. Clearances Panels-Motors-Mech. Equip.
-33. s Mosel Light -Shower Light -Spa Light
oke Detector
Date
Card B-1 Date
Card B-1
Date
Card B-1 Date
Card B-1
Date
M ANICAL (Permit) OK except #'s
Date
FINAL (Plans) OK except #'s
A.0 Ducts Insulation & Support
Ext. Steps_ Door & Sidelight Protection -Landings
. Vent Fan, Exhaust above insulation
urnace Vents -clearance -Comb, Air -Connector -
In G ge; Above Floor-Ducts-Mech. Protection
37 Cyndensate Drain & Overflow, Size & Grade
edam Exiting
Fur ace -Vent Access -Comb. Air -Return Air Vent 115 outlet
. Attic Access & Platform if F� ��n Attic
-Hearth
lec. Outlets at Wood Panel, Int. & Ext.
�72JGirKixt.
7
Date
Card B-1 Date
Card B-1
Date
Card B-1 Date
Card B-1
Date FRAMING (Permit) OK except #'s
W. Sills Proper Materials & Anchors
Walls Studs -Nailing Spacing & Braces -Plates -Sound
Bearing Walls over Girders & Floor Nailing
Draft Stop in Walls rat proof)
4- Fir Stop urred C i firs -Chase -Tub
TW"Headers & Beams- ize earing
FRAMING (Continued)
angers -Post Caps -Anchors -Connectors
g. Joist-Rftr. Ties-Purlin-Roff Brac r s hting.-Ring.
es or Type A Flue -Fireplace hroat Clearance
/ 4Ae- Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles
.50 drm. Windows or Exiting Doors -Sill Ht. & Dimensions
' Garage Fire Protection Framing � L
r52. P V Line Firewal & Openings
Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits
54. ise- un -Landing -Fire Protection
55. P4%vvvd-e"-Roof Overhang -Attic Vents -Rafter Outriggers
St co Mesh -Drip Screed -Fd. Vents-Underflr. Access
',,Glazing Area -Glass Protection -Skylights -Plastic
I� Thear Walls; Nailing -Bolts
60. Brace Interior/Exterior Wall Panels
62.
1 nfiltration-Walls-Windows
Date
Card B•1 Date Card B-1
Date
Card B-1 Date Card B-1
Date
FINAL (Plans) OK except #'s
Ext. Steps_ Door & Sidelight Protection -Landings
Smo etector
urnace Vents -clearance -Comb, Air -Connector -
In G ge; Above Floor-Ducts-Mech. Protection
`6
edam Exiting
G. . & Bath Fixtures & Tub Access-Spe--
Elec. Trim & Subpanel, Breaker Sizes & Labels
-Hearth
lec. Outlets at Wood Panel, Int. & Ext.
�72JGirKixt.
7
& Appliance; Ground -Air Gap -Cooking Clearance
. Outlets & Receptacles at Kit. Counter
Garage Fire Door; Swing -Landing -Closure
NZ
c m Garage -Damper
7
tr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V.
in Garage; Above Floor-Mech. Protection
Ib., Elec. & Mech. Equip. Listed for Location
le Receptacles in Garage (F.F.I.)-Romex Protection
Insulation -Foam -Looked in Attic
a, s & Deck Construction -Post Caps
rawl Hole Door Drainage & Wood -Earth
Clearance Looked under Floor U Yes
82.
Following Instld./Drive - No/W Iks - J No/Planters J Yes
83.
S cc row finish
A.C. Unit Disconnect, Electrical -Plumbing
,r$Srdents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings
86r ectrical, Plumbing
187.
Exter' r Elec. Trim, G.F.I. Receptacle -Underground
entilation Throughout House
ass Protection
90. Corrections from ous I spe`
91. -Gas eter gged, as-Ele ric
r & Sewer Connected -C/O to Grade -HD Approval
n rgy Compliance Certificate -Other Certificates
ddress Posted
Date b
Card B-1 Date Card B-1
Date
Dat
Card B-1 Date Card B-1
Card B-1 Date Card B-1
Comments at Final:
COUNTY -OF BUTTE
BUILDING DIVISION
DEPARTMENT OF DEVELOPMENT SERVICES
411 Main Street • Chico, CA • (530) 891-2751 -
7 County Center Drive • Oroville, CA • (530) 538-7541
CORRECTION NOTICE
OWNER PERMIT NO.
A routine inspection indicates that the following violations of butte county Ordinances exist at the
`above address and should be corrected. Please notice this office when correction of work is
completed. If you have any questions pertaining to this matter, or need additional explanation,
please tact this office immediately.
c
Date 2 Inspector AAQUI
REV 10/92
COUNTY OF BUTTE
BUILDING DIVISION
DEPARTMENT OF DEVELOPMENT SERVICES
411 Main Street • Chico, CA • (530) 891-2751
7 County Center Drive • Oroville, CA • (530) 538-7541
CORRECTION NOTICE
1���, ��� / i0,
OWNER PERMIT NO.
A routine inspection indicates that the following violations of butte county Ordinances exist at the
'above address and should be corrected. Please notice this office when correction of work is
completed. you have any questions pertaining to this matter, or need additional explanation,
please c� act this office
{ immediately. C
Qdz
r
z
,
r
Date
REV 10/92
Inspector
X /—
COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION
7 County Center Drive aOroville, California 95965 • Telephone (530) 538-7541 PERMIT NO.
(Rev. 12/96) APPLICATION AND PERMIT b-1-/2 ��
ASSESSOR PARCEL NUMBER
068-346-023
ZONING
AR
BU I LDI NG P ERM IT
OWNER
KEITH ROBERT
TELEPHONE
532-02
OCC. BUILDING VALUATION
R 110-,430.00
. OWNERS MAILING ADDRESS
41 BUEHL,ER AVE. OROVILL
U 15 426.00
F635.5
CONTRACTOR'S NAME
OWNER
TELEPHONE
C 8,261.50
CONTRACTORS MAILING ADDRESS
CONSTRUCTION LENDER
Fireplace
LENDER'S MAIUNG ADDRESS
Total Valuation $ 132117.50
ARCHITECT OR ENGINEER
M
LICENSE NO.
Filen Fee $
20.00
Permit Fee $
762.00
ARCHITECT OR ENGINEERS MAILING ADDRESS
Plan Checking Fee $
495-30
BUILDING ADDRESS
2 SEM. C -L OROVITLE, CA 95966
Energy Plan Checking Fee $
23.00
PERMIT FEE $
1,300.30
LOT NO. I /
SUBDIVISION'S NAME
PARCEL MAP
PLUMBING PERMIT
Filing Feel 20.00
USEOFSTRUCTURE
SF N Duplex ❑ Mobilehome ❑ Other
SPECIFY
Each Trap 11
7.00 77.00
Solar or heat pump water heater
23.00
Water piping
.15-00 15.00
Each as water heater or vent
15.00 15.00
TYPE OF WORK
New )0 Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑
Describe Work: NEW SF
Gas piping stem 1 - 5 outlets
15.00 15.00
Building sewer
15.00 15.00
Mobile Home I S I G I W I@20.00
PERMIT FEE $
157.00
ELECTRICAL PERMIT
Fling Fee 20.00
Main Service 200AOR's's
23.00 23.00
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter
9 (commencing with Section 7000) of Division 3 of the Business and Professions Code,
and my license is in full force and effect.f
License Class Lic. No. �I�/�(J
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractors License
Lgw_ for the following reason:
1!r"T` I, as owner of the property, or my employees with wages as their sole compensation,
will do the work, and the structure is not intended or offered for sale.
❑ I, as owner of the property, am exclusively contracting with licensed contractors
to construct the project.
❑ 1 am exempt under Sec. Business and Professions Code for this
reason
Main Service 200A TO 1000A
46.00
NEW CONST. DWELLING OCCUR
OR ADDNS. (
SO
2 FT: 101.5
NEWT. MULTI.
SID. O CIRCUITS
97,50
POWER APPARATUS
a SINGLE 0UTLEr C1 R.
Ex. Occup. OUTLET OR FDnURES
20 @'.00
SAL @ .50
Ex. Occup.OFlxvr. Aa OR �
5.00 -00
Temporary Service
23.00
Mobile Home Facilities
20.00
Misc. Wiring
23.00
PERMIT FEE $
149.55
WORKERS' COMPENSATION DECLARATION
1 hereby affirm under penalty of perjury one of the following declarations:
❑ 1 have and will maintain a certificate of consent to self -insure for workers'
compensation, as provided for by section 3700 of the Labor Code, for the
performance of the work for which this permit is issued.
❑ 1 have and will maintain workers' compensation Insurance, as required by Section
3700 of the Labor Code, for the performance of work for which this permit is issued.
My workers' compensation insurance carrier and policy number are:
Carrier
MECHANICAL PERMIT
Filing Fee 20.00
Heating
Cooling
15.00
Hood 1
6.50 6.50
Ventilation 2
4.50MM
9.00
PERMIT FEt $
65.50
Policy Number
(The above sections need not be completed if the permit is for work of a valuation
1 of one hundred dollars ($100) or less.)
I certify that in the performance of the work for which this permit is issued, I shall
not employ any person in any manner so as to become subject to workers'
compensation laws of California, and agree that if I should become subject to the
workers' compensation provisions of section 3700 of the Labor Code, I shall
forthwith co pty with th provisions.
Xe % �� a
Sign ati : of`Applicant - ❑ Owner ❑Contractor Agan
An OSHA permit is required for excavations over 60" deep and demolition or construction
of structures over 3 stories in height. •
Mobile Home Installation Fee $
Energy Inspection Fee $ 46.00
/f
TOTAL FEE $ 1718.35
HAz
D. F I
c
PAPKHD
xs
This permit is hereby issued under the applicable provisions
of the Butte County Code and/or Resolutions to do work
indicated above r wh' h fees hav been paid.
By ..,, Date
PERMIT EXPIRES ON
Date
Receipt No. 324911/56 2.30 S` " . d S
WHITE-D.D.S..B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT
'June 20, 2001
To whom it may concern;'
I hereby authorize the following persons to sign for and actin my behalf in all,
maters concerning the building permit process for the new home to be located at 2 '
Rosemel Ct., lot 15 of the Melrose Estates subdivision in Oroville.
Linda Ames
Malcolm Hall
Larry Kuczler ,
L.C.A. Real Estate
Linda Ames
589-5264
Malamar Construction
Malcolm.Hall`
1-(888)-872-9256 (toll free) ;
State Contractors Lic. 4519150
Larry Kuczler, draftsperson
589-1925
Thank You;,
Robert Keith
41 Buehler Ave..
Oroville, Calif.
532-0230
COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION
7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541
PERMIT APPLICATION DATA SHEET
OWNER: PD6er f - re i i -L ASSESSOR PARCEL NUMBER: 6 ? — q D — 1-5
Proposed Building Use: /Vet,J 5/&,- Building Inspector: & Date: '7— / /_ p I
At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance:
Date Received By
111. All items have been submitted.
El 2. Plot plans, 3/4 sets, signed by the preparer of plans. ----------- --------------------------------------------
E13.
-------------------------------------------
❑ 3 . Complete plans, 3/4 sets, signed by the preparer of plans. -----------------------------------------------------
❑4. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. --------
❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------
❑6. Energy Design Compliance and supporting documentation. ----------------------------------------------------
❑ 7. Statement of Intent for Non -Heated and A/C Buildings. ---------------------------------------------------------
❑ 8. Hazardous Material Form. ------------------------------------------------------------------------------------------
❑9. Manufactured Home data and installation instructions including Tie Down Specifications. ------------------
Feesof $ //51:,, O 6 -------------------------------------------------------------------------------------
11. Impact fees as shown on the attached schedule. -----------------------------------------------------------------
alifornia Department of Forestry plan approval/fees. -��{--¢/�4--------- �4-t------------
❑ 13. Flood elevation certificate. ---------------------------------------------
&C-!�anitation and plot plan approval"ealth Department.
❑ 15. City of Chico plumbing permit. ------------- ----------------------
❑ 16. Plot plan and business license approval from the City of Biggs. ----------------------
❑ 17. Planning approval for (A) Use: 0 1C (B) Parking: -
❑ 18. Contact Land Development about ❑ Improvements, ❑ Draina e�, egal Parcel.
❑ 19. Encroachment Permit for driveway (construction approval prior to occupancy). ---
020. Pre -inspection for
required. Request to Building Inspector on
02 1. Contractor's license information. (Number, Name Style, Classification).
E12,2. Porkers' Compensation carrier and policy number. ----------- ----------------------------
Owner -Builder Verification (Given to owner ❑,ed o
eto GrB �
W_ l_------
❑ Letter of signature authorization.' -------- �iLlke,�_ -
----------
Recorded copy of Agricultural Acknowledgment Statement. --------------------------------------------------
026. Letter of intent on building use. ---------------- y ---------------------------------------------------------------
❑27. Manufactured Home utility clearance.---------------------------------------------------------------------------
❑28. Existing violations and/or expired permits. -------2------------
029. 0433 A, ❑Grant Deed, ❑ M.H. Title, ❑ Check to H.C.D $
030. Other: (
(Date)
�0 - C',
Wh you issueVermit, process as follows ❑ Mail to owner, ❑Mail to contractor.
�1Tele hone D 3 v and hold for rcku at �r0V r E' office. ❑ eliver
P p p inspector.
Applicant: Date:
Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, ❑ Air Poly Date:
Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Other: Date: By:
1. Index permit application for the above items numbered: L0 1 ❑ Plan Check List
2. Additional items required:
Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date:
Contractor, designer, owner, was advised of the above required data by ❑ phone,. ❑mail, `❑ Building Division counter, by Date:
Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date:
Contractor, designer, owner was advi a of the above required data by ❑ phone, ❑ mail, ❑ Building D�sion counter, by Date:
Plans reviewed by: Date: Plans approved by: O� Date:
Sets of plans on hold in ❑ Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: 7 19,_ e5
Yellow Copy - Department of Development Services, Building Division. =�^�42
4
COUNTY OF BUTTE
DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION
7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965- TELEPHONE (530) 538-7541
SCHEDULE OF FEES DUJ S
OWNER D �U �r f` tc e
PROPOSED BUILDING USE
r"
f
1.
BUILDING PERMIT FEES
f
Due
$
--Balance .......................................................
--Additional Fees Due............:�.............................
a`
$
--Additional Fees Due ............................................
$ '
--Revised Plan Checking Fee .................................
$
2.
SCHOOL DISTRICT FEES
0 rQ
(paid at District Office)
3.
SHERIFF FEES (paid at Building
Division)
Residential ....................................
x $360.00 = $
Units
Commercial (sq. ft.) ...................... x $0.03 = $
Sq. ft.
4. URBAN AREA FEES
Residential ............................—x—=$
# Units Amt.
Commercial (Sq. ft.) ............. X—=$
Sq. ft. Amt.
'^ A.P. #
DATE 7._11 d�
RECEIPT # DATE REC.
5. RECREATION DISTRICT FEES
6. THERMALITO DRAINAGE DISTRICT FEES
$510.00 (paid at Building Division)
—47. SRA FIRE INSPECTION AND PLAN CHECK
$89.00 (paid at Building Division) P 4L -711116 t
/Lei. � 3ayQr
8. WATER TENDER FEES (Battalion # )
$200.00 (paid at Building Division)
9. CSA 87 TRAFFIC FEE
$2500.00 (paid at Building Division)
10. OTHER
At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees
may be changed during the plan checking procels.
APPLICANT / DATE %1�/d/
Pursuant to Goverrggepnt Code Section 66020, you are hereby notified that items 2, 3, 4, 5, 6, 7, 8, 9, and 10 above may have been
imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned
items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a).
Original - Building Div. 2nd Copy - Applicant . 3rd Copy -Owner (Rev. 6/00)
�z( �`' ���"++""'bS'^T3i•rs-�'„�,eS^y'�}�1•^i�"Tr7C'„7"'Y �r'���4'"ii �{�fB�'t,S. ;��S�a-,- ...-..i.,,yryR .r =. .,�,.. ..� .. •.,w:��;�r,e.w-q.' '.'•r ,'~ s _ . ,
i
4 .
• BUTTE.COUNTY SCHOOLS IMPACT FEEGERTIFICATION FORM
(One form per Building)
F School District Cj Building Department No.
A.P. Number j/,� ~ /J.o� �j Jurisdiction: City County
Property OwnerQ
Property Location/Address
Subdivision 7 / iG ('� �% J7'� 7 Lot No. / S
...............n C
Residential Development Sq. Footage
No of Living Mobile Home Addition/ 'Supplemental to (Group R)
Units Installation Conversion Permit #
'(No foundation inspection):
............. ......................................................................................................
.
Commercial/Industrial Sq. Footage
New Addition (Including Exterior
Roofed Areas)
Building Department -Representative Date
(Floor Plans reviewed by School District Personnel)
District Identification No.
School District certifies that
/W (Applicant)
(Street Address) (Phone Number)
(City) (State) (Zip Code)
p has complied with the requirements of Resolution No. 1?g by payment of $ �9 S
�# representing �Q square feet. AB 2926 E
FULL MITIGATION $
School District Representative Date
Paid by Check # ,, �' Remarks:
90
_Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with
Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit
you from challenging the imposition of the fees in any court action.
If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification'Form; the School District is
notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA),
this proiect may be subiect to additional school fees to fully mitigate its impact on the school district's schools.
White (applicant), Yellow (building department), Pink (school district) feeform.xls (10/98)dmm
• t; r yF�. � �,�:a' tea• � r ,
-14
COPY. of Document .Recorded
A,VD WHEN RECORDED MAIL TO: 20-JU1-i®®1 2®®1-®032®07
t BUTTE COUNTY BUILDING DM310N Has not been compared with.
7 COUNTY CENTER DRIVE t original
OROVILLE. CA 95965
�,..` BUTTE COUNTY RECORDER
AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT
FOR RESIDENTIAL DEVELOPMENT
Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. .The
property described herein is adjacent to land or included within an area zoned'for agricultural purposes, and residents of this
property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to
herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation,
plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established
agricultural purposes and residents .within. said zones and on adjacent property should be prepared to accept such inconvenience
or discomfort from normal, necessary farm operations:
All that real property situate in the County of Butte, State of California, described as follows:
Date . ZO d 0 / _ PROPERTY OWNERS:
Ai
State of California )
County of ' )
On20 Z before mei
personally appea d i 6C I, y
�+ �� �+e (or proved to me on the basis of satistacto evidence) tote e the person(s) whose names) ' subscribed to the within
instrument and acknowledged to me that �� a zecuted the same in his/60/ e r authorized capacity(ies), and that by
his/b�ee*signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, executed the
instru
WITNESS my, hand official se
Al
Signatu GCCC.� Lill Seal:
�-GG �. PA TI GRAY 1 .
ko MY11585p3 M
A. P. # - �f0 ^•JS' �
I 1 2001
ORDER NO: BU -187452-3
i
LEGAL ,
DESCRIPTION:
THE LAND REFERRED TO IN THIS REPORT IS SITUATED IN THE STATE OF .
{
CALIFORNIA, COUNTY OF BUTTE, AND IS DESCRIBED AS FOLLOWS:
PARCEL I: :.., _ -•
LOT 15', AS SHOWN ON THAT CERTAIN MAP ENTITLED, "MELROSE ESTATES",;
WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY._:
:--
OF BUTTE, STATE OF CALIFORNIA, ON FEBRUARY 15, 2001, IN BOOK 151 OF
MAPS, AT PAGE (S) 15,. 16 AND 17.
THIS DEED IS•MADE AND ACCEPTED UPON THE COVENANTS, CONDITIONS AND
RESTRICTIONS AS SET FORTH IN -THAT CERTAIN DECLARATION OF
RESTRICTIONS RECORDED FEBRUARY 20, 2001, UNDER BUTTE COUNTY
RECORDER'S SERIAL NO. 2001-06572, BUTTE COUNTY, CALIFORNIA; ALL OF
WHICH ARE INCORPORATED HEREIN BY REFERENCE THERETO WITH THE SAME
FORCE AND EFFECT AS THOUGH FULLY SET. FORTH HEREIN AT LENGTH AND
GRANTEES BY ACCEPTANCE OF THIS DEED APPROVE, ADOPT, RATIFY AND
AGREE TO THE TERMS OF SAID DECLARATION.:
.
APN,068-346-023-000 (PORTION)
PARCEL II:
A RIGHT OF WAY FOR ROAD AND PUBLIC UTILITY PURPOSES OVER LOT 3151
AS SHOWN ON THAT CERTAIR MAP ENTITLED, _:'OROVILLE'WYANDOTTE FRUIT
LANDS UNIT NO. 611, WHICH MAP WAS RECORDED IN THE OFFICE OF THE
RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON MARCH 8,.
1929, IN BOOK 10 OF MAPS, AT PAGE(S) 3A, 4A AND 5A.
--
_ _...
w
i
i
PERMIT NO.: 46-01
3
Lake. Oroville Area Public Utility District,,
1960 Elgin Street
OROVILLE, CALIFORNIA 95966 `
533-2000 r
DISTRICTAPPROVAL AND
VERIFICATION OF INSPECTION
BUILDING SEWERS, `
This verification form must be submitted to the Butte County Department of Public Works Building .
Department prior to issuance of a building or occupancy permit, whichever is applicable.
Prior to final approval by Butte County of a Building or.an Occupancy Permit, a copy of this verification
form, signed off by Lake Oroville Area Public Utility District, must be submitted to Butte.County.
Date: June 13, 2001
j
Applicant: ROBERT -E. KEITH (Malamar Constr.) i
Applicant Address: 41 Buehler Ave.-,'Oroville, CA 95966
Applicant Phone No.: 532-0230 '
Y a
Property Locations(s): 2 Rosemel ; Court
Melrose Estates Lot #15
A
A. P. No.(s): 68-346='9
Fees due: All fees paid 6/13/01
5 i
l
Application for service approved:
` LAKE OROVILLE AREA
PUBLIC UTILITY DISTRICT
Inspection(s) made and successful test(s) observed:
ti
Location: Date:
By:
Lake Oroville Area Public Utility District release to close permit: '
Date: By.
RESIDENTIAL PLAN
REVIEW GUIDE
SINGLE FAMILY, DUPLEXAArD
MISCELLANEOUS ONLY
I?wner-. Building Permit Number:"
Plans Examiner: Linda Simpson A. P. Number:
GEGE RAL:
Zoning requirements – (number of permitted living units).
lans signed by the designer.
oper description of work on the application.
sting' violations on the property.
Recorded notice of violation.
Zoning
0
Recorded
B w
uilding permit valuation.
TL T PLAN:
mplete parcel size and dimensions..- tbacks, side yard, easements, etc.
Other buildings'or structures.
Other
fills and/or drainage.
Flood hazard.
ecial c0 nditlon§,?n Parcel Map:
Noise D SFire Sprinklers ❑ Water Tender E1 Traffic and Drainage:fees C]
Federal Aid Rodfie and/o" r Federal Aid Secondary Route setback requirement
Building or utilities
-across lot lines (Lot merger approval by Butte.County Land Develo
pment.)
R PLAN:
Plans and specifications drawn to scale with dimensions and of sufficient clarity (UBC section 106.3.3).
10% of natural light and 5% of ventilation (Uniform Building Code section 1203).
scape or rescue windows shall have a minimum net clear openable area of 5.7 square feet. The minimum net
clear openable. height dimension shall be 24". The minimum net clear I openable width dimension shall be 20".
When windows are provided as a means of escape or rescue, they shall havea finished sill height not more than
44" above the floor (Uniform Building Code section 310.4).
Skylights (Uniform Building Code section 2409 & 26033).-
-.5 —Glazing in Hazardous locations (Uniform Building Code section 2406).
Habitable space shall have a ceiling height -of not less than 1 feet 6 inches except as otherwise permitted in this
section. Kitchens, halls, bathrooms and toilet compartments n*y. have a ceiling height of not less than 7 feet
measured to the lowest projection from the ceiling (Uniform Building Code section 310-.6. 1),
All habitable rooms except kitchens shall have an area of not less than 70 . square feet and not less. than 7 feet in
any dimension (Uniform Building Code section 310.6.2 & 310.6.3).
GFCI in baths, garage, kitchen, wet bar,
and exterior receptacles (NEC 210).
Water heaters which. depend on the combustion of fuel shall not be-instklled'in a room used or desJigned to be'
used for sleeping purposes, bathroom, clothes closets or in a closet or other confined space opening into a bath'
or. bedroom (Uniform Plumbing Code section 509.0).
uel burning equipment shall not be installed in a closet, bathroom or a room readily usable,as a bedroom;; or in
a room, compartment or alcove opening directly into any of these (Uniform Mechanical Co§iba 394.5).
. F
P
clear0
sc'
lea
Iaj
C
V
u
0
a
Garage firewall separation - required on garage side including supporting walls and posts (Uniform Building
C
Code section 302.4 exception 0),
L
Under no circumstances shall a private garage have any opening into a room used for sleeping purposes
(Uniform Building Code section 312.4)
Wood stove. location - Alcove _ UMC section 205 confined space 223 unconfined space & 304.2).
S
Smoke.detectors (Uniform Building Code section 310.9.1).
Page .1 of 1
t
ater closet clearances (Uniform Plumbing Code 408.5).
shower compartment minimum 1024 sq. in. & 30" circle (Uniform Plumbing Code 412.7).
Bearing walls shall be supported on masonry or concrete foundations that shall be of sufficient size to support
allloads (Uniform Building Code section 1806.3).
UCTURAL DETAILS:
raced wall panels shall start at not more than 8 feet from each end of a braced wall line. Braced wall panels
must be in line or offset from each other by not more than 4 feet (UBC section 2320:11.3). Spacing shall not
exceed 34 feet on center in both the longitudinal and transverse directions (UBC section 2320.4.1.) Braced wall
lines must be continuous throughout the structure.
A California licensed architect or registered engineer must prepare a lateral analysis for the areas of the building
that do not comply with the Uniform Building Code. This must include the designer's "wet" stamp, signature,
registration number and expiration date on all sheets of plans depicting the designed elements and cover sheets
of calculations.
Clerestory requiring balloon framing and/or engineering.
Foundation plans complete enough to construct building (Uniform Building Code Table 18 -I -C).
Floor construction details complete enough to construct building.
Elevations and wall construction details complete enough to construct building.
Roof construction details complete enough to construct building.
Fireplace construction details and calculations if necessary.
Garage door header size(s).
Porch header size(s).
Typical header size(s).
Stud heights.
High expansive soil — special foundation design required.
Retaining walls requiring design.
Gypsum wallboard nailing inspection required.
If the area below the lowest floor is fully enclosed, than a minimum of two openings are required with a total
net area of at least one square inch for every square foot of area enclosed with the bottom of the openings no
more than one foot above grade. Alternatively, certification may be provided by a registered professional
.engineer or architect that the design will allow equalization of hydrostatic flood forces on exterior walls.
Building must be designed and anchored to prevent floatation, collapse or lateral movement_ Construction
design requirements must be shown on the building plans.
Electric, heating, ventilation plumbing and air conditioning equipment and other service facilities shall be
designed and/or located so as to prevent water from entering or accumulating with the components during
conditions of flooding.
MISCELLANEOUS ITEMS: ,
i
"ay details — landings, rise and run, head clearance, handrails (Uniform Building Code section 1006).
rdrails (Uniform Building Code section 509).
ck or stone veneer (Uniform Building Code section 1403).
erior plaster — weep screeds (Uniform Building Code section2506.5).
f pitch for roof covering (Uniform Building Code Table 15-B-1& 2, 15-D-1 & 2).
m insulation — protection. halls and stairways (Uniform Building Code section 1004.3.3.2).
o exits on three — story dwellings (Uniform Building Code section 1004.2.3.2).
erfloor access and ventilation (Uniform Building Code section 2306.3 & 2306.7).
c access and ventilation (Uniform Building Code section 1505).
nd requirements.
rgy design compliance and supporting documentation.
F responsible area requirements.
ING PERMIT REQUIREMENTS:
1. SRA.
2. Flood elevation certificate.
3. ❑ Fire Sprinklers required.
4. ❑ Special Inspection requirements.
5. ❑ Use Permit conditions.
6: ❑ Sub -Standard Housing letter.
Page 2 of 2
f SITE PLAN REVIEW APPLICATION
ppj
. Date:AP#
Ofi 8 - 3y (b orl >
Permit Number (if applicable) b 8
APPLICANT INFORMATION Parcel -,Size:.:.
Owners Name: k C IT H• 120 iS 5Qr
Owners Address: y) r3U C-" LG Q -Al/6 On-a>yI LLs
Telephone No..
Situs Address:. n Q10 -S
Proposed Use:
Residential ,
New Single Family Residential .
❑ Single Family Addition ❑ Single Family Remodel
❑ Mobile Home
❑ Residential Accessory '
❑ . Permanent Second Dwelling , .
❑ Temporary Mobile Home (Aunt -Minnie) = ,
❑ Temporary Travel Trailer -
❑ Multi -family
Non-residential
❑ New Commercial ,
❑ • Commercial Addition ❑ Commercial Remodel
❑ New Industrial .
❑ Industrial Addition ❑ Industrial Remodel
Other ;
❑ Septic ❑ Well
❑ Agricultural Exempt Building
❑ Other:
Brief Explanation (if necessary):
DO NOT WRITE BELOW THIS LINE
DEVELOPMENT SERVICES INFORMATION (For Staff Use)
`Approved ❑ 'Conditionally Approved ❑ Resolve Problems Prior to Approval'
❑ Site Plan Stamped Approved
By Date
Page 'l of 5
ALL ITEMS CHECKED APPLY TO THE PROPERTY
Parcel Is In:
❑ Snow Load Area:
❑ Land Conservation Act Minimum Acreage: ❑ Verify residence can be built per contract
❑ Nitrate Action Plan (See Environmental Health for standards)
❑ Watershed Protection Overlay Zone (See attached standards and requirements)
❑ Expansive Soils (Test for expansive soils and if verified proper foundation design required)
® SRA - (CDF to determine specific requirements)
❑ 100 -Year Flood Plain: (See a4aphed)
• Flood Zone: Ix '
• Flood Panel No.: Index Date: 6 ' ' 9 g
❑ Sacramento River Reclamation District (Approval must be obtained from the California Reclamation Board)
❑ Feather River Reclamation District (Approval must be obtained from the California Reclamation Board)
❑ North Chico Specific Plan (See Development Fees Section and attached standards and requirements)
❑ Chapman/Mulberry (See attached standards and requirements)
❑ Cohasset Area (See attached standards and requirements)
❑ Grading Zone (See attached handout)
Use Requires:
❑ Use Permit ❑ Minor Use Permit ❑ Administrative Permit
❑ Minor Variance ❑ Variance
---------------------------------------------------------------------------------------------
❑ Detached Building Use Form ❑ Encroachment Permit
❑ Agricultural Worker Affidavit ❑ Agricultural Acknowledgement Statement
Zoning: A - R
Applicable Building Setbacks:
❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks.
Page 2 of 5
Zoning Code
Streets & Highways
Fire Prevention
Subdivision Map
Front
-Sp
Side
Side Street
Rear
Height
Waterway
N/A
N/A
N/A
❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks.
Page 2 of 5
K f Y',4�i Y�.S' �% 4 J •
Applicable Development Fees:
f, *. .
Standard Fees 'Amount Formula
❑ Fire J
El
School* ,
❑ 'Parks/Recreation .
❑ Roads
❑ Sheriff
❑ Drainage
❑ NCSP/CSA 87
❑ Chico Urban Area Road
❑ Thermalito Impact
❑ Other
Subdivision Map Special Fees
❑ Water Tender
• S
Road Improvement -
❑ North Oroville Area
❑ Other (per map)
• Check with school district to verify'actual fee if pre -application review. A final determination will be made at the time of
the building permit.
Parcel Created By
❑ Deeds:
Date of Creation: Legal Access Provided: ❑ No ❑ Yes
Deed of Reference: Legal Access Required ❑ No, ❑ Yes
Parcel Frontage on Publicly -Maintained Road: ❑ No" ❑ Yes, Road Name:
Complies with County Standards for Deed Creation: ❑ No ❑ Yes ,
.Comments:
❑ Parcel Deemed to be. legal '
❑ Verify Legal Parcel ❑ Verify Legal Access []Provide Deed of Creation
❑ Obtain a .Certificate of Compliance ,
❑ Obtain a Merger ❑ Obtain a Lot Line Adjustment
❑ Comply with 'Old Subdivision Lot Ordinance (Maps recorded prior to Book 17. of Maps Page 23).
F-1 Cons truct road to: El Meet Parcel size required by.zone
❑ Meet current Environmental Health Department requirements -
Page 3 of 5
Subdivision Map/Parcel Map:
Map Date of Recording
Lot: 1 S
❑ Use Permit/Minor Use Permit
Permit Number:
Book: IS)
Date of Approval:
❑ Comply with the following Conditions of Approval:
❑ Meet the Fire Safe Regulations of Butte County and P.R.C. 4290
Page: ) 5 17
❑ Automatic fire suppression sprinkler systems shall be installed in accordance with the
National Fire Protection Association Standard for installation of sprinkler systems in one
and two family ,dwellings and mobile homes, NFPA Standard 13D, unless a pressurized
community water system, with hydrants that meet the Fire Department specifications, serves
the parcel.
❑ Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission
requirements of the California Clean Air Act of 1988, as amended.
❑ Provide an erosion control plan for building and land disturbance on slopes steeper than
30%. The Erosion Control Plan must be prepared by a registered civil engineer or other
qualified professional and be submitted to and approved by the Department of Public
Works.
❑ A plan prepared by a certified arborist, botanist or landscape architect that shows the existing
on-site mature trees, located in any area proposed for buildings and vehicular access, and
provides for methods to protect the trees identified to be preserved, shall be provided to and
approved by the Planning Division prior to the issuance of building permits and/or prior to
grading or vegetation removal. The removal of mature trees shall be minimized, where
possible. A mature tree shall be defined as a tree with a trunk measuring 4 inches in
diameter, 4 feet from ground level. Mature trees removed shall be replaced on a 3 -to -1
ratio, utilizing existing oak tree stock. Each tree to be preserved shall be surrounded by a
circular zone (minimum. 40 -foot radius) identified by an orange fence during construction
activities. No vegetation removal, soil disturbance, or other development activities shall
occur within the fenced area.
❑ Measures shall be taken to control fugitive dust emissions from all driveway and other civil
construction associated with residential development. Approved dust control measures are
found in the fugitive dust control plan for the site approved by the Butte County Air Quality
Management District, a copy of which can be obtained from the Butte County Department
of Development Services, Building Division."
❑ Engineered foundations are required.
❑ Class A roofs are required.
Page 4 of 5
.FROM HALL CONSTRUCTION
Ji/ Cis VL lJJ• JJ
INC PHONE NO. 507 465 044 Nov. 29 2001 10:58AM P3
leJI 1V1\I �I IVI \ 1 V 1111 -IV`• I I � V� • • �WYI • '•W� � •� �- --- - ..
L
CERTIFICATION OF INSUtoATION
1Afhite - B~ espy, amm - Oulider cepa. Vellerr - CuBic"r OW
Pink • Atiilc copy! (laid - Pilo mW
..PU—c,-+21-0C 04.:03PM FROt,- >,
T-463. P-01/01 F-210 .
c-C.•� �r�+a4 'x:47 t-K lJVVKLKrir r_V,,, / Bio
o-,.:j ocou .. . ... ...
RAFT
1.7,�~w`•z i �''•q.� fi� �+,'G�.,�.t•L: st �; <.rxPan ojcho)s1.D. WE
fdMity • ..
..
�.,\ r r Jay r i � a+it.:T�x•�' ..•
}.
..,
L
A'el.sgtirtaer 10; y 99&
TO WHOM CONCERNED.
DOORCRAFT OF CALIFORNIA MANUF `
TURES ALL 1-3/4" THICK'
PARTICLEBOARD AND LUMBER CORE DOORS'
O THE APPROVED TEST
SPECIFICATIONS OF WARNOCK HER5EY.INT14NATIONAL
FOR 20 MINUTE _
CONSTRUCTION. DOORS CONSTRUCTED 16AED
FACILITY, THAT ARE SENT TO
D18TRIBUTORS FOR MACHINING ARE INK S
ON THE TOP RAIL FOR RATED
CONSTRUCTION. METAL LABELS ARE APPLT
DOORGRAFT IF WE.MACHINE THE
DOORS, OR BY THE LICENSEE THAT MACHINES
THE DOORS.,
RESPECTFULLY,
MARK BLETHEN '
ARCHITECCRJRAL MANAGER
1
A•
r
a `
"
I
3911! C�irrcinrr,rrr.;rkrlun - ljreC� irr, c'.1 YS 76,5 - (%16) i8Q-497)OfI r r
.-.\ 016j 144 -82R - SALES 1-800-744-6(99
m* TOTRL PRGE.001 **