Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
069-090-052
69- 09- si AP -Wr-�a- M.L. Barham (Lot 25, KR #2A)r 64 Greenbrier Dr., Oroville Permit. 3127-75 P,E (util/M ELEC . %� GAS SUP00RT STRUC. REQ. COMPACTION TEST REQ, ®. 3 `tIl,,Permit# ONTR: Carnero,.. MH Transp. , Na ( �Q J a(iT ► -Q,� 3810 75MHI s sued , = 6 177-5' Permit #4492-75 B (carport, covered d ck, open deck) Q L , G i U t, r IY • i r f r 0 CSI �G" crx� 4 de5f/Z MH UTIL. PERMIT N0. 3127-75 P,E P L E { M JMH UTIL. PERMIT NO. / rG2' ` / PERMIT EXPIRES .OWNER - M.L. Barham owner �icONTR. 34-66-2 LOCATION (A.P. ) j 64 Greenbrier Dr., Oroville (Lot 25, KR 2A) Y J w' f - 1 �F 1 L (l1 f I' f {� Temp. Power Pole i Called PG&E •dewy—Elec. Serv.�' Called PG&E Temp. Gas Serv. Called PG&E / OB FIINALED (Date) (Signatu ) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING I BUILDING (Cont'd) PLUMBING Setback Firewall Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor Stemwall Siding To out Slab Roof Sheathing Water Piping Piers Roofing Sewer Garage Fdn. Vents Fixtures Footings Garage Vents Water Htr. Stemwall Slab Prov. for physically handicapped Heaters Appliances Carport Footings Conformance of ex. structure Gas Piping & Test Temp. Gas Slab Final Sanitation Patio FIREPLACE Final Footings Footing ELECTRICAL Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam FIRE SPRINKLERS Motors Framing Test Water Htr. Stucco Final Subpanels Mesh MECHANICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final DATE REMARKS OR CORRECTIONS 1. MOBILEHOME INSTALLATION INSPECTION CHECK LIST Is. the mobilehome located with required separation from lot lines and buildings and generally conform to plot plan? Yes�.No 2. Does the mobilehome have required clearances above ground? (Sec.5085) Yes No 3. Are footings and supports properly sized, spaced, and braced as per approved plans? (Note possible variation at spring shackles.) (Sec. 5082 & 5083) YeX No 4. Is the mobilehome level? (Sec. 5088) Ye54 No 5. If mo e than a single unit, are crossover connections properly installed?.(Sec. 5088) Yes No 6. Water A. Is flexible connector of adequate size and properly installed (1/2" ID min.)? (Sec. 5566) Yes No B. Test - Does water piping withstand working pressure or 50 lbs. air test? Yes -'X No C. Backflow - If coach is not State of California approved, does station have backflow device and pressure -relief valve? Yes_ No 7. Wastes and Drains A. Is connection made with Schedule'40 DWV and have flex connectors at each end? Yes�C No B. Does it have minimum" per foot slope and is it properly supported? Yes X No C. Are any leaks detected in drainage system after running 3 -gallons of water through each fixture including washing machine standpipe?,.Yes Nom D. If coach is not State of California approved, does station have required trap and vent? Yes—No- 8. esNo8. Gas Piping and Gas Vents A. Connector - Is mobilehome connected to the gas supply with an approv 3/4" minimum mobile e connector not more than 6 ft. long? Note: All piping 's to be at least as .large as a mobilehome gas line •iril'et without reductions othe han the mobilehome connector. No B. Test OK as per follo 'ng procedur. Y N 1. Open all appliance nnector, al VU0 2. Shut off appliance burner d pilo alves. 3. Air test with manome>cal'brated to 0'� 14 ,Tater column, or test with slope gauge (minimum 6oz.-maximum 8 oz.) in, enpound increments_. Test for 10 min. without drop. 4. Connect me gas r to mobilehome with connector, urn on gas, test connections with soapy water C. Are all appliance vents properly installed? Yes No I 9. Electrical A. Is service large enough to provide adequate amperage -to mobilehome (must equal rating of mobilehome with a minimum of 100 amp) and othgr facilities on lot, i.e., water pumps, garage, cabana, etc.? Yes_K No - B. Is there proper clearances around panels? Yes )r --_No r C. Is power supply cord or feeder assembly properly fused? Yes No D. Is continuity test satisfactory as per the following procedure? Yes -2! --No De -energize electrical wiring system of the mobilehome at the pedestal. Make sure that the power supply cord or feeder assembly conductors, including neutral conductor, have been disconnected. l/ 3. Switch all breakers and switches in the mobilehome to the "on" position. 4. Connect one lead of a test instrument to the mobilehome grounding conductor and // apply the other lead to each mobilehome supply conductor, including neutral.. /' S. All non-current, carrying metal parts of the mobilehome (aluminum siding, gas line, water line), including fixtures and appliances, shall be tested for continuity from such equipment and the grounding conductor. /6. Upon completion of the above procedure, the power supply cord or feeder assembly conductors shall be connected to the.site service equipment. A further continuity test shall then be made between the grounding electrode and the chassis of the mobilehome. Upon satisfactory completion of the electrical tests, the lot or site service equipment may be approved for. energizing. , 10. Is job card signed by Health Department for water and sanitation? ,v j1/ � 11. If everything okay, sign off card and tag services. MOBILEHOME DATA Manufacturer and/or Namestyle Length_ Width .Z Vehicle Serial No. 1-23V /_1 State Identification No. 2=0260x' Additional Information or Comments: COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WO KS --7J' 7 County Center Drive — Oroville, California 95965 'Te'lephone: 534-4541 APPLICATION AND PERMIT aunwrice representatives of the County of Butte to enter upon th above-mentioned property for inspection purposes. Date 36 / J Signal re of Permitee r Agent . \q Receiot No. 134 W This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PLAIC WORKS BY � i<at.e9--6lding permitexpiresDate..................................�.:�a BUILDING Owner Mr, & Mrs. M. L. Barham SQ. FT. OCC. BUILDING VALUATION Mailing Address 1072 D, Los Gamos Road San Rafael, California 94903 Telephone No. 415-479-1731 Fireplace Contractor Cameros Mobile Transport Total Valuation Mai I i ng Address 1290 EL Capitan Permit Fee Plan Checking Fee &/or Penalty Napa, California 945583b ± r,h P0241.1 Permit Fee $ $ Building Address 64 Greenbrier DrivePLUMBING No.1 @ FEE PERMIT FILING FEE $2.00 Oroville, CA 95965 Each Trap 1.50 Lot 25 Unit 2—A Repair drainage or vent piping 1.50 Water piping 1.50 Each gas water heater or vent 1.50 A. P. No. 34-66_ Zoning &Planning Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 F W-6. I SaiMMon FireDept. FireZone Use Permit Building sewer 5.00 EQA Parking Plans I Parcel Declaration Parcel Ma 60' R/W p Im r p ove nts Lawn sprinkler system 2.00 Bldg. Plans Recd Parcel Approval Plans tpproval Permit Fee $ $ NEW ❑ ADDITION UTILITIES ❑ OTHER ® ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Installation I91 Main service incl. 1 meter _ Additional meters, each 1.00 Sub -panel (12 or less) (more than 12) Single Family ❑ Duplex ❑ Mobil Home Others ❑ Range, Cook -top or Oven 1.00 Water Heater or Space Heater 1.00 Light fixtures 201%2 o Receps., switches & fix outlets X12 CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: Cameros Mobile Transport Hood, Ex. Fan or F.A. Furn. Motor 1.00 Evap. cooler, gar. disp. or D.W. 1.00 Air conditioner or heat pump Water pump Mobil Home Facilities 5.00 Temp. Power Pole 5.00 License No. 269158 Classification C-61 Misc. wiring ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ® I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ Mobile Home Installation $ 30 -- TOT AL PERMIT FEE $ 30 0 aunwrice representatives of the County of Butte to enter upon th above-mentioned property for inspection purposes. Date 36 / J Signal re of Permitee r Agent . \q Receiot No. 134 W This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PLAIC WORKS BY � i<at.e9--6lding permitexpiresDate..................................�.:�a ' COUNTY OF BUTTE — DEPARTMENT OF PUBLIC W• KS %� 7 County Cent„ Drivef — Oroville, California 95965 /�✓ �� Telephones 534-4541 L/ APPLICATION AND PERMIT l�F1WQUr L1VeS u uic wunty ui tnuiie iu enter upon the above- entioned p per for inspection purposes. X Date 7S- Signatureof Permitee or Agent Receipt No. zg.:, 76k White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR O"UBLIC WORKS BY�Z �✓` _�--- Date-�/ --`4-- Building permit expires Dat9 7""2— BUILDING Owner SO. FT. OCC. BUILDING VALUATION Mailing Address 1�10r J /L Q. ,5 rAl".16s , C# Telephone No. Fireplace Contractor �� Total Valuation Mailing Address Permit Fee Plan Checking Fee &/or Penalty Telephone No. Permit Fee $ Building Address PLUMBING No.1 @ FEE PERMIT FILING FEE p 1�[���LyGFGG� Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1 Each gas water heater or vent 1.50 A. P. No. I'?-/- (G (p - Zonir? P Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 F FireDept. FireZone Use Permit Building sewer 500 EQA Parking Plans Parcel Declaration Parcel Ma P 60' R/W Im ro ments P Lawn sprinkler system 2.00 B g� n��r%c'd Parcel' rovol Plans Approval Permit Fee $ 54,ein $ �( NEW ❑ ADDITION ❑ UTILITIES OTHER ❑ ELECTRICAL No.1 @ FEE PERMIT FILING FEE $3.00 ,toC) Main service incl. 1 meter 3.0o Additional meters, each 1.00 Single Family ❑ Duplex ❑ Mobil Home Others ❑ Sub -panel (12 or less) (more than 12) Range, Cook -top or Oven 1.00 5 CA-- OcO14 Water Heater or Space Heater 1.00 Light fixtures -20 _bal_ X10 Receps., switches & fix outlets ai na i CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: Hood, Ex. Fan or F.A. Furn. Motor 1.00 Evap. cooler, gar. disp. or D.W. 1.00 Air conditioner or heat pump Water pump Mobil Home Facilities Temp. Power Pole 5.00 License No. Classification Misc. wiring am exempt from the Contractors License Laws of the State of California. Permit Fee $ ,Ob $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. . ❑ I have placed on file with the County of Butte a certificate of W kmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No.1 @ FEE PERMIT FILING FEE J$3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby TOTAL PERMIT FEE $ l�F1WQUr L1VeS u uic wunty ui tnuiie iu enter upon the above- entioned p per for inspection purposes. X Date 7S- Signatureof Permitee or Agent Receipt No. zg.:, 76k White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR O"UBLIC WORKS BY�Z �✓` _�--- Date-�/ --`4-- Building permit expires Dat9 7""2— C❑❑ TES James Glander Department of Public Works 7 County Center Drive Oroville, California Re: 75258 Dear Jim: s ENGINEERING CONSULTANTS 2060 PARK AVENUE OROVILLE. CALIFORNIA 95965 PHONE (916) 539-6457 CALIFORWA P. E. NCVADA P. C. OREGON P. E. July 17, 1975 Compaction test results are enclosed for mobile home site preparation at Kelly Ridge Estates for: _;- Kelly Ridge -Es, a. es """'"---i"54 1 Heise 192. 1 Representative tests taken indicate that the 90% relative compaction requirement has been satisfied. A location map is attached. AGB/cap Enclosures Very truly yours, COOK ASSOCIATES I Alan G. Brown Civil Engineer DR. LLOYD M. COOK ED, D. JOE E. COOK M. E. DAN J. COe'f< C/E. Il V Project Barham KRE 25-2A COQ ASSOCIATES Job Number ENGINEERING CONSULTANTS Nuclear in -Place RTaken By Alan Brown OROVILLE Moisture Density Test July 1975 , CALIFORNIA 95965 Date (91 6) 533-6457 TEST NUMBER 1 2 3 4 5 6 7 8 9 10 TIME 1st lift 1st lift 2nd lif I Fin Su TEST S Cor Same S Cor S Cor LOCATION of fill of fill "FAIL" RETEST" 7-4-75 7-12-75 7-12-75 7-17-7 MODE 8 DEPTH 8" DT 4" DT 81" DT 8" DT MOISTURE COUNT 843 972 1094 810 MOISTURE COUNT RATIO •595 .686 .775 .571 MOISTURE PCF 14 .. 0 . 17.0 " 19.50 13.50' DENSITY COUNT 326 672 230 236 DENSITY COUNT RATIO 1.185 2.443 .833 .858 WET DENSITY PCF 122.5 135.5 138.0 136.5• DRY DENSITY PCF 108.5 118..5 118.5 123.0 MOISTURE -13 14 16 11 OPTIMUM DENSITY PCF 132 132 132 132 OPTIMUM .10 10 10 10 MOISTURE % RELATIVE COMPACTION 82 90 90 93 STANDARD COUNT COMMENT: 7-4-75 t MOISTURE DENSITY 1415 275 1415 1411 1418 275 7-8-75 276 7-12=75 275* 7-17-75 �- 9t9P . _ 7C—/004.4 _ FL.— .O c 997 ou ( CIO 30 —�— W / S /01 /5f 9*90 xMH.E/ 9*/6.3 - 'Ti TO SfT _ y'�� loll / ©A-FA-.t - / \ '04 / F _ d = 50°27'02' 1 \ / _ - s R= 300 26V T= 134.26" .10 4" H53 - _ r = //5.90' P 5.1.40 8 . co ' c.'�' ons TEST LOCA MO N ......... ............:. ::::' ::::: o::::::: ::::::'':::::: ......: ::::::� ::::::�::::::: ::::: :::: ::::::: ::::::: :::':: :::::::°....:::: .:....a:...... ...: ...................c�.................c4..........:.:.....:....:............ ....... ....... ,................ip...�.:.,::.:.:'::::':.. i....... ....... :;....... :....... #........ . ;N :....... ... ::..:::.. i...:.:.:.:.:.:.:.:...........:......:.....::.:.::.::.—....:...:........::.:.... .. ... . . rn f 1 'PERMIT NO.' 4492-75 B i( P 1� E M MH UTIL. PERMIT NO. •1 1' PERMIT EXPIRES/ M.L. Barham OWNER _ it CONTR. Owner LOCATION (A.P. _34C`.6h-02 64 Greenbriar Drive, Oroville 1 Temp. Power Pole Called PG&E _ Temp. Elec. Serv.. Called PG&E Temp. Gas Serv. _ Called PG&E _ JOB ���/// ,Fl NALED COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) . PLUMBING Setback — T Firewall Soil Piping Forms Parapets 1 st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor Stemwall Siding I To out Slab Roof Sheathing Water Piping Piers Roofing Sewer Garage Fdn. Vents Fixtures Footings Garage Vents Water Htr. StemwaII Slab Prov. for physically handicapped Heaters Appliances Carport Footings Conformance of ex. structure Gas Piping & Test Temp. Gas Slab Final © c1 Sanitation Patio FIREPLACE Final Footings Footing ELECTRICAL Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam FIRE SPRINKLERS Mot Framing a Test Wat Stucco Final Sub Mesh MECHANICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final DATE REMARKS OR CORRECTIONS —' COUNTY OF BUTTE ;1 DEPAFKMENT'OF PUBLIC WORKS 7 County Center Drive — Orovi Ile, California 95965 Telephone: 534-4541 APPLICATION' AND PERMIT Z/ e- r/9a - 2s authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. ,Aw3 7- X QUI Date SignatureofPermitee or Agent Re ipt No. White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. x DIRECTOR OF- PUBLIC WORKS', By Date J Building permit expires Date. 6 BUILDING Owner SQ. FT. OCC. BUILDING VALUATION �! Mailing Address164 o, 00 Telephone No. S` Contractor Fireplace Total Valuation .3 , 00 Mailing Address Permit Fee Plan Checking Fee&/or Penalty Telephone No. Permit Fee 8 00 is Z O� Building Address ., PLUMBING- No. @ FEE % PERMIT FILING FEE $3.00 Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 AX.2 Each gas water heater or vent 1.50 f �y A. P. No. (p C% 02. Zoning & Planning Gas piping system 1 - 5 outlets 1.50 Each additional outlet _30 F s Fire Dept. Fire Zone Use Permit Building sewer 5.00 EQA Parking Plans ParcelLawn Declaration Parcel Map 60' R/W I Improvements sprinkler. system 2.00 Bldg. PI ns Recd Parcel pproval Plans Approval Permit Fee _ $ NEW ADDITION ❑ -UTILITIES[] OTHER ❑ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Main service incl. 1 meter Additional meters, each 1.00 Sub -panel (12 or less) (more than 12) Single Family ❑ Duplex ❑ Mobil Home Others ❑ Range, Cook -top or Oven 1.00 /f Q� Water Heater or Space Heater 1.00 •" Light fixtures b lag 019 Receps., switches & fix outlets CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: Hood, Ex. Fan or F.A. Furn. Motor 1.00 Evap. cooler, gar. dis,p. or D.W. 1.00 Air conditioner or heat pump Water pump Mobil Home Facilities 5.00 Temp. Power Pole 5.00 License No. Classification Misc. wiring D- I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ MECHANICAL No.1- @ I FEE WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑ I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. X I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. PERMIT FILING FEE J$3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ I certify that I have read this application and state that the'above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby TOTAL PERMIT FEE $ �� authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. ,Aw3 7- X QUI Date SignatureofPermitee or Agent Re ipt No. White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. x DIRECTOR OF- PUBLIC WORKS', By Date J Building permit expires Date. 6