HomeMy WebLinkAbout069-130-008David M. .Keesling -,� �O ~7
58 Lodgeview Dr. loitl
, KR# Oro.
Permit �k 7 9-76P,E(u.,MH)
ELEC .� I�' . (o S
GAS
SUPP RT STRUCTURE REQ. IVO
COMPACTION TEST REQ.
CONTR: Carneros Mobile Transport, Na
ermit #2786-76MHI
Xssued_c:2
contr: Duralum, Sactamento
Per t #5173-'7 B(new deck & awning/MH)
yea 1 ��%�
69-13-8 F1
rpcer'mit#2802-85B,
ontr: Doyle Carter
^��VE(new garage) 1018ap5
Y_t
r
Rol
CMI CWD
IMMI
t
r
PERMIT NO. 2802-85B,E
PERMIT EXPIRES
OWNER DAVID M. KEESLING
CONTR.. Doyle W. Carter
ASSESSOR PARCEL
69-13-8
3
LOCATION Lodgeview Dr, Oro
• �
r
:i
i
i
Temp. Power Pole
r
t
Called PG&E
Temp. Elec. Service
f'
j Called PG$F
Temp. Gas Se
Cal led PC
JOB FINALEI
Signature
I
V ='OK ' -
O = Not OK
- = Not Applicable MOBILEHOMES
* = Not Ready
MISCELLANEOUS
Date
MOBILEHOME UTILITIES (Plans) OK except #'s
1. Zoning Requirements -Setbacks -Easements
Date
DECKS, COVERS, CARPORTS, ETC. (Plans) OK except #'s
1. Zoning Requirements -Setbacks -.Easements
2. Soils; Special MH Support -Sketch
2. Footings; Size -Depth -Spacing -Connectors
3. Sewer; Location -Test -Fall -C/O -Concrete
3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails
4. Water; Location -Test -Easement Needed (Sketch)
4. Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Bracing
5. Electricity;. Location-Clearances-Grnd.-/ / Amp -Concrete
5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures
6. Gas; Location -Test -Wrap:/ /"L"ft./ /"Nat. or/ /"L"ft./ /"LPG
6. Carports; Windows -Doors
7. Utility Clearance
7. Elec.
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date
Date Card -BI Date
MOBILEHOME INSTALLATION (Plans) OK except #'s
1. Zoning Requirements -Setbacks -Easements
Card -BI
Date
Date Card -BI Date
POOLS (Plans) OK except #'s
1, Setbacks -Easements
2. Footings; Size -Spacing -Marriage Line
2. Soils; Compaction -Structure Stability
3. Gas; MH Test -Demand -Valve -Connector
4. Electricity; MH Test -Crossovers -Breakers -Clearances
5. Drain; MH Test -Fall -Flex Connector
3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining
4, Elec.; Receptacles and Lighting; Distances-GFI
5. Elec.; Pool Lighting; 15 volts-GFI
6. Water; MH Test -Regulator -Connector
7. Water and Sewer Connected -C/O to Grade -HD Approval
6. Elec.; Enclosures; Conduit Entries -Terminals -Listed
7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater
B. Gas and Electricity Tagged
8. Elec.; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg.
Boxes -Enc losures- Pane lboards-Ins. to Main in Conduit
9. Health Department Approval
9. Exits; Insp.-Sketch
10. Cert. of Occupancy
10. Plumb; Cir. Test -Water Supply Test
Card B -I
Date Card -BI Date
Card -BI
Date Card -BI Date
Card B -I
Date Card -BI Date
Card -BI
Date Card -BI Date
= OK
= Not OK a
= Not Applicable RESIDENTIAL (Single and Duplex)
= Not Ready
Date
UND LOOK Plans OK exce t#'s
Date
FRAMING Continued
Zoning requirements -Setbacks -Easements ""
48. Property Line Firewall & Openings
Soils-Steel-Elec. Grnd.- / /" Fig. Depth
boors -One 3' -Check Garage -3rd story, 2 exits
tg., Garage; Soils -Steel- / ;L4!' Fig. Depth
50._Stairs Width -Headroom -Rise -Run -Landing -Fire Protection
-4 -.Fly., Porches & Decks; Soils -Steel- / /" Ftg. Depth
51;,Pf wood.on,Roof Overhang -Attic Vents -Rafter Outriggers
alls, Main; Steel-Blockouts-Wrapped-Slab
5 iding-Nailing-Veneer
Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab
51:. -Stucco M sh-Drip Screed-Fdn. Vents-Underfir. Access
7. Piers -Fireplace Ft .-Steel
54•,_Gla7ing Area -Glass Protection -Skylights -Plastic
8. D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test
9. Gas Pipe; Size -Anchors
55. Shear Walls; Nailing -Bolts
10. Water Pipe; Test -Anchors -Regulator -Service Test
11. Electric; Underground
12. Plenums & Ducts; Clearance -Material -Support -Ins.
13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples
C 'rd=Bl
_/Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date/ y Card -BI Date
Date
FINAL,(Plans) OK except q's
Card -BI Date Card -BI Date
Date
PLUMBING (Permit) OK except q's
14. Water Ht.; Vent -Access -Combustion Air
15. Water Pipe; Test & Anchors -Nall Protection
5 Ext. Steps -Door & Sidelight Protection -Landings
57._.Smoke.Detector
5§--Euraace; Vents -Clearance -Comb. Air -Connector -
In Garage; Above Floor-Ducts-Mech. Protection
16. D.W.V.; Test-Fttngs & Anchors -Nail Protection
50 --Bedroom Exiting
Fixtures & Tub Access
17. Shower Pan; Test, First Floor -Tub Accessft-1mr-F4-Bath
18. Test Tub & Shower, 2nd Floor -Tub Access
Elec. Trim & Subpanel; Breaker Sizes -Labels
19. Gas Pipe; Size & Anchors
62_S1airs.&_Rails
63r•FFreptace-or Stove; Clearances -Hearth
64. -Elea. -Outlets at Wood Panel; Int. & Ext.
Card -BI
Date Card -BI Date
i . A liance; Grnd.-Air Gap -Cooking Clearance
Card -BI
Date
Date Card -BI Date
ELECTRICAL Permit OK except q's
667-MeMoUttets & Receptacles at Kit. Counter
Garage Fire Door; Swing -Landing -Closer
88--A-C-D'at°t-in Garage -Damper
Fixture &Transformer Clearance -Ins. Protection
69.-Wtr.-fftr-Vents-Clearance-Comb. Air-Connector-P.R.V.-
In Garage; Above Floor-Mech. Protection
¢9!Elec. Receptacles Spacing -Lights & Switches at Doors
7 . & Mech. Equip. Listed for Location
Size_Boxes & No. of Conductors -Stapled
7 lec. Receptacles in Garage; (G.F.I.)-Romex Protec.
7Q---Foam-Foam-Looked in Attic ❑ Yes
3%Romex Installed Close to Edge of Studs & C.J.
g,.fEquip. Ground made up w/Mech. Fasteners -Bond Gas & Water
7 r ai s &Deck Construction -Post Caps
-25.2 Appliance Circuits in Kitchen & Conductor Size
X-26, Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al
nts & Crawl Hole Door -Drainage & Wood -Earth Clearance
Looked under Floor ❑ Yes
-2T.-Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al,
Insulated Neutral []Yes❑No
nstld.: Drive
73^�°❑Yes E) No; Walks El Yes [I No;
Planters ❑Yes ❑No
-Z8':--Service-Riser Conductors & Ground -Main Disconnect
7 o, Brown -Finish
29. -Equip. Clearances; Panels-Motors-Mech. Equip.
77_-AvG-U q;.Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet
30:-^G'lothes Closet Light -Shower Light
ove Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs.
79. ll; Disconnect, Electrical, Plumbing
-E-lec. Trim; G.F.I. Receptacle -Underground
B-�
Date Card BI Date
84v-b'artttMtion throughout House
Card 8 I
Date
Date Card -BI Date
MECHANICAL (Permit) OK except q's
31. A.C. Ducts; Insulation & Support
82. Glass Protection
orrections from Previous Inspections
as T st-Meters Tagged; Gas -Electric
85 ater & Sewer Connected -C/O to Grade -HD Approval
32. Vent Fan; Exhaust above Insulation
8 nergy Compliance Certificate -Other Certificates
33. Condensate Drain & Overflow; Size & Grade
34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet
35. Attic Access & Platform if Furnace in Attic
Card -BI A
Date and -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Comments at Final:
Date FRAMING Plans OK except q's
ills; Proper Material & Anchors
all • Studs -Nailing, Spacing & Bracing -Plates -Sound
3 ea ' ails over Girders & Floor Nailing
39t r op in Walls (rat proof)
40 ire s; Furred Ceilings -Stairs -Chases -Tub
41^ er & Beam -Size & Bearing
42. ars-Post Caps -Anchors -Connectors
4 CI -Rflr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfng_._
4 ace Ties or Type A Flue -Fireplace Throat
4 A cess; Size & Romex Protection -Draft Stop -Ins. Baffles
4 m. Windows or Exiting Doors -Sill Hgt. & Dimensions
47 Garage Fire Protection Framing
(NOTE: Anentrymust be made each time youvisit jobsite)
r t COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PESM.IT N .
7 County Center Drive - Oroville, Californiga 95965 - Telephone 916/534-4541
APPLICATION AND PERMIT
ASS R ARCEL NUMB
ZONING
BUILDING PERMIT
ERv7r�7G ` �ee�i4
TELEPHONE
SO. FT. OCC. BUILDING VALUATION
OWNS MAIL =ES
ADDV CSGs/ �C/ CSVI
TRACTO NAME TELEPHONE
ol.S L
R OR'S MAILING ADDRESS
;� ,r!/�
Fireplace
C NSTRUC ION ENDER
UNKNOWN
Total Valuation Is
Filing Fee
$ 10.00
LENDER'S MAILING ADDRESS
Permit Fee
$
ARCHITECT OR ENGINEER
LICENSE NO.
Plan Checking Fee
$
Penalty
$
ARCHITECT OR ENGINEER'S MAILING ADDRESS
Permit fee
$ 0A ac
BUILD!ADDRESS
PLUMBING PERMIT
Filing Fee 10.00
Each Trap
2.00
Solar Water Heater
20.00
Water piping
5.00
LOT NO.
_
SUBDIVISION NAME
// /
,, .deo>�
PARCEL MAP
1
Each qas water heater or vent
5,00
Gas piping system 1 - 5 outlets
5.00
USE OF STRUCTURE
SF ❑ Duplex ❑ Mobi lehome ❑ Other
SPECIFY
Building sewer
5.00
Mobile Home S I G I W I
1 110.00 e
TYPE OF WORK
New [/Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑
Describe work: r2-° X �/1-e-e
Permit Fee
$
Contractor
ELECTRICAL PERMIT
Filing Fee 10.00
Main service e00V OR LESS
100 AMP OR LESS
10.00
Main service/EA, ADD'L 100 AMP
2.50
NEW CONSTDWELLING 0
OR ADDNS. ( ACC. BLDGS.
21/20sgft
CONTRACTORS LICENSE LAW
I declare u er penalty of perjury (Check one):
I am licensed under provisions of Chapt. 9, Div. 3 of the Business
and Professions Code and my license is in full force and effect.
��Q A /
License No. ���`� O Classification
❑ I, as the owner, or my employees with wages as their sole compen-
sation, will do the work,and the structure is not intended or offered
for sale. (Sec. 7044)
❑ I, as the owner, am exclusively contracting with licensed contract-
ors. (Sec. 7044) -
❑ I am exempt under Sec. , Business and Professions Code
for this reason
NEW CONSTR. U TI -OUTLET 2.50 ea
NO N.RESID BRANCH CIRCUITS)
NEW CONSTR. ( POWER APPARATUS &)
NON.RESID. SINGLE OUTLET CIR.
20050a
Ex. Occup(o OR FIXTURES SAI -0300
FIXED TS (REAPPLS, OR
FIXED
EX. Occup. OUTLETS (RESID.) EA, 2.00
Temporary service 10.00
Mobile Home Facilities 15.00
Misc. Wiring 15.00
Permit Fee $ all V 0
Contractor
MECHANICAL PERMIT
FiIingFee 10.00
WORKMEN'S COMPENSATION INSURANCE
I declare under penalty of perjury (check one):
❑ Th permit is for $100.00 (valuation) or less.
have placed on file with the County of Butte Building Department
a Certificate of Workmen's Compensation Insurance or a Certificate
of Consent to Self -Insure.
❑ 1 shall not employ any person in any manner so as to become subject
to the W. C. laws of California.
Notice to Applicant: If after making this statement, should you become subject
to the W. C. provisions of the Labor Code, you must forthwith comply with such
provisions or this permit shall be deemed revoked.
Heating
Cooling
Hood
3.00
Ventilation
permit Fee
$
Contractor
I certify that I have read this application and state that the above information
is correct. I agree to comply to all County Ordinances and State Laws relating
to building construction, and hereby authorize representatives of the Countyot
Butte to enter upon the above-mentioned property for inspection purposes.
I also agree to save, indemnify and keep harmless the County of Butte against
lities, judgments, costs, and expenses which may in any way accrue
again al_ County in cons hen9ranting of this permit.
X �
Sign". -r. -of Applicant — Owner [IContractor[Agent ❑
An OSHA permit is required for excavations over 5'0" deep and demolition or construct-
ion of structures over 3 stories in height.
Mobile Home Installation Fee $
TOTAL PERMIT FEE $
OCCUP. GROUP
I TYPE OF CONST.
PARCEL
PD
[__!41:71
This permit is hereby issued under
sions of the Butte County Code and/or
work indicated above for which
DIRE 1fOR OF PUBLIC
By.
,v
PERM T EXPIRES Date
the applicable provi-
resolutions to do
fees have been paid.
WORKS
Date
!X�
�J_ /r✓
Receipt No. �����
WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT
�xrsi�Nq C.oac�
-I' �, p �o
vi V
v`
1-4 x
z
v
Y e
Z �,
rr,4 r) (A
\01
I
COP
IX-
NOTE:—An Materials & War'
Accordance with Recognized
of a quality Prescribed for the
Uniform Building, Plumbing & M
the Nationd Eectrical Code.
o----
mashi�Shce�� o
'oo P c is an
echo
d h
$pe afield Lse
icali t�odew or► v
This set of plans and specific
kept on the job at all times and
make any chonges or alter++ons o
written permission from the !
Works, County of Butte.
i ns W)ST ht
a
oq �
�d T
i✓71-L-7_T_"`._�-::G".O_C_A.T_!d/�CS__.i4.? `
0-'.7-!-7-0--'5-'--Cii L E_ ;_.. '
LOT .136
UNIT 1
W
A setback of 5 ft. from the
orope'rty lines and a setback
I of 50ft. from the road
centerline shall be clear of
structures or equipment except
nor a 2 ft. eave overhang.
14)
01
0
a
0
�UTTE COUNTY
Ali,, ING DEPARTMENT
PPROVED
Z-/
All
IV .Stv.os...
WA&L tl fzb -WIAI
5'
114
OV.
U&I Of 5 MIL 9W-
14 3A44 rM
n"
i
Provide 1/2" x 10" anchor bolts
@ b' O.C. max. and within
112" of joints.
r-�-E
" S)ab
b
PERMIT NO. 5173-76B
PERMIT EXPIRES
OWNER D.. Keesling
CONTR. Duralum, Sacramento
LOCATION (A.P. 34-62-8 �
58 Lodgeview, lot 136,'KR#lC, Oroville
0
Temp. Power Pole
Called PG&E
Temp. EI �Serv.
Cal d PG&E
Temp Gas Serv.
ailed PG&E
JOB
FINALED I 1 - / - 7L
(Date)
(Signa re
COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS
BUILDING INSPECTION RECORD
BUILDING BUILDING (Cont'd) PLUMBING -
Setback / / — / —7L
Firewall
Soil Piping
Forms
Parapets
1st Floor
Main Bldg.
Restroom Finish
2nd Floor
Footings
Windows
3rd Floor
StemwaII
Siding
To out
Slab
Roof Sheathing
Water Piping
Piers
Roofing
Sewer
Garage
Fdn. Vents
Fixtures
Footings
Stemwal I
Garage Vents
Insulation
Water Htr.
Heaters
Slab
Carport
Footings
Prov. for phy sically
handica ed
Conformance of ex.
structure
A' liances
Gas Piping & T
Temp. Gas
Slab
Final
Sanitation
Patio %
FIREPLACE
Final
Footings
Footing
Masonry Walls
Throat
Rough
Reinf. Steel
Final
Fixtures
Bond Beam
FIRE SPRINKLERS
Motors
Framing — / — %
Test
Water Htr.
Stucco
Final
Subpanels
Mesh
MECHANICAL
Grd. Fault Prot,
Scratch
Heating
Service
Brown
Cooling
Temp. Pole
Finish
Ducts
Underground
Interior Lath
Ventilation
Permanent
Door Closer
Final
Final
DATE
REMARKS OR CORRECTIONS
(NOTE: An entry must be made on this form each time you visit the job site.)
ELECTRICAL
COUNTY OF BUTTE - DEPARTaEN4T OF PUBLIC WORKS
7 County Center Drive — proville, California 95965
Telephone: 534-4541
APPLICATION AND PERMIT
BUILDING
Owner D. KEESL I NG SQ. FT. OCC. BUILDING VALUATION
270
Mailing Address 58 LODGEV I EW N. 10 X 2 DECK
48 2 II X 68 AWNING
KELLY RIDGE, OROV I LLE Telephone No. /0 �®
-
Contractor
Mailing Address P •0. BOX 261249
SACRAMENTO
Building Address
Telephone No.
ic. Low 13�
A. P. No. 8(4 •Q? Zoning& Planning
F)V< I VC. I Fire Dept. Fire Zone Use Permit
EQA Parking Parcel el M 60' R/W Improvements
Plans Declaration /� P p ovements
Bldg. Plans Recd ��el f1pproval ns Approval
NEW YJ ADDITION ❑ UTILITIES ❑ OTHER ❑
Single Family ❑ Duplex ❑ Mobil Home Others ❑
CONTRACTORS LICENSE LAW
I am licensed under the provisions of Chapter 9, Div. 3, of the
State of California Business & Professions Code under the name
style of:
License N Q%* -Q Classification
I am exempt from the Contractors License Laws of the State of California.
WORKMEN'S COMPENSATION INSURANCE
I am aware of the provisions of Section3700 of the California Labor
Code which requires every employer to be insured against liability
for Workmen's Compensation.
I have placed on file with the County of Butte a certificate of
Workmen's Compensation Insurance.
I certify that in the performance of the work for which this
permit is issued I shall not employ any person in any manner
so as to become subject to the Workmen's Compensation Laws of
California.
I certify that I have read this application and state that the above
information is correct. I agree to comply to all County Ordinances
and State Laws relating to building construction, and hereby
authorize representatives of the County of Butte to enter upon t6
above -menti property for inspection purposes.
XZ Date
Slgnot re of Permitee or Agent
Receipt No. -
S a S3�g
White-D.P.W. — JCA— Pink -Inspector — Go_denrod-Applicant
Total Valuation I
Permit Fee _
Plan Checking Fee &/or Penalty
Permit Fee
PLUMBING
PERMIT FILING FEE
Each Trap
Repair drainage or vent piping
Water piping
Each gas water heater or vent
Gas piping system 1 - 5 outlets
Each additional outlet
Building sewer
Lawn sprinkler system
Permit Fee
BAL@1
@L,,
ELECTRICAL
PERMIT FILING FEE
Main service
601v OR LESS
100 AMP OR LESS
Main service
EA. ADD'L 100 AMP
Main service
OVER 600V
100 AMP OR LESS
Main service
EA. ADD'L 100 AMP
NEW CONST. (
OR ADDNS.
DWELLING OCCUP. &
ACC. BLDGS.
NEW CONSTR.
NON-RESID,
/MULTI.OUTLET
l BRANCH CIRCUITS
NEW CONSTR(POWER
NON RES D.
APPARATUS &
SINGLE Ol1TLET CIR.
$3.00
1.50
1.50
1.50
1.50
1.50
.30
5.00
2.00
$3.00
5.00
2.50
25.00
1.00
!¢ sq ft
!.50ea
E
>- o
FEE
FEE
Ex. Occup(OUTLETS OR FIXTURES
BAL@1
@L,,
EX. OCCU FIXED APPLNS, OR
p• OUTLETS (RESID.) EA)
2.00
Temporary service
10.00
Mobile Home Facilities
15.00
Misc. Wiring
6.25
Permit Fee $
MECHANICAL No. @ FEE
PERMIT FILING FEE $3.00
Heatino
I Cooling I I I I
Ventilation
Hood 1 1 2.00
Permit Fee $ $
Liu f L1C A �� L A ✓S ' �C>
TOTAL PERMIT FEE $
This permit is hereby issued under the applicable provisionS,01f��
the Butte County Code and/or resolutions to do work indic
above for which fees have bee paid.
DIRECTOR F UBLIC WORKS
BY Dated / (e % 0
uilding permit expires Date �6 77
PERMIT NO. 1719-76P;E
PERMIT EXPIRES ,�(—/6 7 7
.;OWNER David M. Keesling
j
CONTR. owner
LOCATION (A.P. 34-62-8
i
58 hdgeview Dr., lot 136, Mil, Oroville
0
r '
F
�p
0
y
Y.
i
1
y
Temp. Power Pole
Called PG&E
Temp. Elec. rv.
Called G&E —// 7L
Temp. as Serv.
lied PG&E
FINALED_— l8 /C Al !T
(Date)
(Signatu )
COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS
BUILDING INSPECTION RECORD
BUILDING - BUILDING (Cont'd) PLUMBINr,
Masonry Walls
Reinf. Steel
Bond Beam
Framing
Stucco
Mesh
Scratch
Brown
Finish
Interior Lath
Door Closer
DATE
FIRE SPRINKLERS
MECHANICAL
Heating
Cooling
Ducts
Ventilation
Final
REMARKS OR CORRECTIONS
Rough /
Fixtures
Motors
Water Htr.
Subpanels
Grd. Fault Prot.
Service
Temp. Pole
Underground
Permanent
Final
(NOTE: An entry must be made on this form each time you visit the job site.)
L
Setback ZQ "2
Firewall
Soil Piping
Forms
Parapets
1st Floor
Main Bldg.
Restroom Finish
2nd Floor
Footings
Windows
3rd Floor
Stemwall
Sidinq
To out
Slab
Roof Sheathing
Water Piping ' 'ZO
Piers
Roofing
Sewer —/ —
Garage
Fdn. Vents
Fixtures
Footings
Garage Vents
Water Htr.
Stemwall
Slab
Prov. for physically
handicapped
Heaters
Appliances
. Carport
Footings
Conformance of ex.
structure
Gas Piping & Test
Temp. Gas
Slab
Final
Sanitation
Patio
FIREPLACE
Final
Footings
Footing
ELECTRIC
Masonry Walls
Reinf. Steel
Bond Beam
Framing
Stucco
Mesh
Scratch
Brown
Finish
Interior Lath
Door Closer
DATE
FIRE SPRINKLERS
MECHANICAL
Heating
Cooling
Ducts
Ventilation
Final
REMARKS OR CORRECTIONS
Rough /
Fixtures
Motors
Water Htr.
Subpanels
Grd. Fault Prot.
Service
Temp. Pole
Underground
Permanent
Final
(NOTE: An entry must be made on this form each time you visit the job site.)
L
COUNTY OF BUTTE
DEPARTMENT OF PUBLIC WORKS 7 COUNTY CENTER DRIVE
OROVILLE, CALIF. - 534-4541
CERTIFICATE OF OCCUPANCY
This mobilehome has been installed in accordance with the requirements
of the California Administrative Code, Title 25, Chapter 51 under permit
number for the following location:
Owner
Owner's Address ' ,
Mobilehome Mfg. Model Year
Insignia No. Serial No.
It is hereby certified for occupancy at the above described location and
may be occupied.
Director of Public Works
Date / By
THIS CERTIFICATE IS VOID WHEN MOBILEHOME IS*ELOCATED
9. Electrical
A. Is service large enough to provide adequate amperage. to mobilehome (must equal rating of
mobilehome with a minimum of 1:00 amp) and other facilities on lot, i.e., water pumps,
garage, cabana, etc.? .Yes
B. Is there proper clearances around panels? Yeses No
C. Is power supply cord or feeder assembly properly fused? Yes 4No_j
D. Is continuity test satisfactory as per the following procedure? Yes _Lo
1. De -energize electrical wiring system of the mobilehome at the pedestal.'
2. Make sure that the power supply cord or feeder assembly conductors, including neutral
conductor, have been disconnected.
3. Switch all breakers and switches in the mobilehome to the "on" position.
4. Connect one lead of a test. instrument to the mobilehome grounding conductor and
11 me supply conductor, including neutral.
apply the other lead to each T�l.oblle
e�. 5. All non-current., carrying metal part's of the mobilehome (aluminum siding, gas line,
water line),• including fixtures and appliances, shall be tested for continuity from
such equipment and the grounding conductor.
6. Upon `'completion of,ithe above procedure, the power supply cord or feeder.assembly
conductors. shall be connected to the site service equipment. A further continuity
test 'shall then be made between the grounding electrode and the chassis of the
mobilehome. Upon satisfactory completion of the electrical tests, the lot or site
service equipment may be approved for energizing.
10. Is job card signed by Health"Department for water and sanitation?
11. If everything okay, sign off card and tag services.
MOBILEHOME DATA y � � Ver /`� I/Manufacturer and/or Namest le, '
Length -,64 Width 7_ �1
Vehicle Serial No.
State Identification No. -c`3 /503
Additional:Informati_on or Comments:
-
r
MOBILEHOME INSTALLATION INSPECTION CHECK LIST
1:
Is
the mobilehome located with required separation from lot lines and buildings and generally
�o
conform
to plot plan? Yes
2.
Does
the mobilehome have required clearances above ground? (Sec.5085) Yes— No
3.
Are
footings and supports properly sized, spaced; and braced as per approved plans? (Note
possible
variation at spring shackles.) (Sec. 5082 & 5083) Yes 4�-_No
4.
Is
the mobilehome level? (Sec. 5088) Yes— No
.5.
If
more than a single unit, are crossover connections properly installed? (Sec. 5088)
Yes
"o
6.
Water
A.
Is flexible connector of adequate size and properly installed (1/2" ID min.)? (Sec. 5566)
Yes 4,�--N o
B:
Test - Does water piping withstand working pressure or. 50 lbs, air test? Yeses No
C.
Backflow - If coach is not State of California approved, does station have backflow device
and pressure -relief valve? Yes_ No
7.
Wastes and Drains
A.
Is connection made with Schedule 40 DWV and have flex connectors at each end? Yes— No—
oB.
B..
Does it have minimum k" per foot slope and is it properly supported? Yes /--No
C.
Ate any leaks detected in drainage system after running 3_P llons of water through each
fixture including washing machine standpipe? Yes No
D.
If coach is not State of California approved, does station have required trap and vent?
Yes No
8.
Gas
Piping and Gas Vents
A.
Con ector - Is mobilehome connected to the gas supply with n approved 3/4" minimum
mob ehome connector not more than 6 ft. long? Note: 1 piping is to be at least as
large as the mobilehome gas line inlet without reductions other than the mobilehome
connect Yes No
B.
Test OK as per llowing procedure? Yes No
1. Open all apple ce connector valves..
2.. Shut off appliance b er and pilot alves.
3. Air test with manometer to "- water column, or test with slope gauge (minimum
6oz.-maximum 8 oz.) calibrat in tenth pound increments. Test for 10 min. without
drop.
4. Connect gas meter to mo ilehome with nnector, turn on gas, test connections with
soapy water.
C.
Are 411 appliance vent properly installed? Yes No.
COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS
7 County Center Drive Ocgwille, California 95965
Telephone: 534-4541 �]O/ —%
APPLICATION AND PERMIT /
authorize representatives of the County of Butte to enter upon the
above-mentioned property for inspection purposes.
Dat /
$i na r o Permitee or
Receipt No. Da
White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant
This permit is hereby issued under the applicable provisions of
the Butte County Code and/or resolutions to do work indicated
above for which fees have been paid.
DIRECTO,R OF PUBLIC WORKS
By Date A;68 7C -
permit expires Date _SA5�/T7
BUILDING
Owner David M. Keesling
SQ. FT. OCC. BUILDING VALUATION
Mailing Address
Telephone No.
Fireplace
Contractor Carneros Mobile Transport
Total Valuation
Mailing Address 1290 El Capitan
Permit Fee
Plan Checking Fee &/or Penalty
NApa, California 94558
elephone No. T
252-2411
Permit Fee $
Building Address 58 Lodgeview HKIR Drive
PLUMBING No.1 @ FEE
PERMIT FILING FEE $3.00
Oroville, California 95965
Each Trap 1.50
Repair drainage or vent piping 1.50
Water piping 1.50
Each gas water heater or vent 1.50
A. P. No.Gas
34-62-08
Zoning 8 Planning
piping system 1 - 5 outlets 1.50
Each additional outlet .30
F
W
Semta++Qn FireDept.
FireZone
Use Permit
Building sewer 5.00
EQA
Parking
Plans
Parcel
Declaration
Parcel Ma P
60' R/W
ImprovementsLawn
sprinkler system 2.00
Bldg. loni� s Recd
Parcel Ap ovol
Plons provol
Permit Fee $
$
NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER
ELECTRICAL No. @ FEE
PERMIT FILING FEE $3.00
Installation�-
For -e ral 11 0 �747'7�
600V OR LESS
Main service 100 AMP OR LESS 5.00
Main service EA. ADD'L 100 AMP 2.50
Main service R 600V
100 EAMP OR LESS 25.00
Single Family ❑ Duplex ❑ Mobil Home 0 Others ❑
Main service EA. ADD'L 100 AMP 1.00
NEW CONST. DWELING
OR ADDNS. ( ACCLBLDGS.CCUP. &) 20sgft
NEW CONSTR. MULTI -OUTLET
NON.RESID. BRANCH CIRCUITS)-2.50ea
NEW CONSTFi. (POWER APPARATUS &)
NON.RESI D. SINGLE OUTLET CIR.
CONTRACTORS LICENSE LAW
I am licensed under the provisions of Chapter 9, Div. 3, of the
State of California Business & Professions Code under the name
style of:
Carneros Mobile Transport
Ex. Occup(OUTLETS OR FIXTURES) 50 BAL�
Ex. Occup. (OUT LETSP(RES(D.)REA) 2.00
Temporary service 10.00
Mobile Home Facilities 15.00
License No. 259158 Classification C-61
Misc. Wiring 6.25
❑ I am exempt from the Contractors License Laws of the State of California.
Permit Fee $
$ 77—
WORKMEN'S COMPENSATION INSURANCE
1 am aware of the provisions of Section3700 of the California Labor
Code which requires every employer to be insured against liability
for Workmen's Compensation.
®have placed on file with the County of Butte a certificate of
'Workmen's Compensation Insurance.
❑I certify that in the performance of the work for which this
permit is issued I shall not employ any person in any manner
so as to become subject to the Workmen's Compensation Laws of
California.
MECHANICAL No. @ FEE
PERMIT FILING FEE $3.00
Heating
Cooling
Ventilation
Hood 2.00
Permit Fee $
$
1 certify that I have read this application and state that the above
information is correct. I agree to comply to all County Ordinances
and State Laws relating to building construction, and hereby
Mobile Home Installation
30.00
TOTAL PERMIT FEE
$ 30.TO
authorize representatives of the County of Butte to enter upon the
above-mentioned property for inspection purposes.
Dat /
$i na r o Permitee or
Receipt No. Da
White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant
This permit is hereby issued under the applicable provisions of
the Butte County Code and/or resolutions to do work indicated
above for which fees have been paid.
DIRECTO,R OF PUBLIC WORKS
By Date A;68 7C -
permit expires Date _SA5�/T7
A
BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS
7 County Center Drive, Oroville, CA.
PHONE: 534-4541
MOBILEHOME INSTALLATION SHEET
1. Owner's name: David M. Keesling
2. Installer's. name:. Carneros Mobile Transport
3. Is the site. -currently under.permit? Yes /x / No
(If yes, furnish permit number 1719-76 ) OR
Is the site an existing site? Yes:/ / No /x /
(If yes, furnish two (2) plot plans...)-
. -.
4. Will the mobilehome be located at least 5 ft. away from septic tank.and.leach fields -and
clear of all setbacks and easements? Yes /x / No
(If -no, clarify )
5. What. is the mobilehome electrical rating? ---------------=------- 200 Amps
6. What is the mobilehome site service rating? --------------------- 200 Amps
7. What is the mobilehome site circuit breaker rating? ------------- - ZOO Amps
8. Is there -any other electric load to be served by the mobilehome
site service? -------=----------------------------------- ------ Yes / / No /x /
(If yes, identify the load and size: (Load) ---- (Amps)
f
9. What is the mobilehome site gas pipe'size?--------------------- ---- (in.)
10. What -is the type of gas service? ----------------------------- Natural. / /- LPG
11. What is the.gas pipe length,.from meter or tank to the mobilehome? ---- (ft.)_
12. What is the mobilehome gas demand. ----------- ---- (BTU)
f
(This infbrma.tion not...r..equired if pipe length less than 6 ft. on natural. gas.
or less than -50 ft. on LPG.)
? 10
' j
01
00
MOBILEHOME SU rr0KT DATA
Mobilehome Mfr. Mountain Valley "' Setup Model No. 3BR F&R 28A Year 76
Width 24 (ft.) Length .. 66 (ft.) -Expando Size — ft.x ft. `
(Draw support details below)
On all mobilehomes manufactured after October 7, 1973, furnish manufacturer's.installation
manual and structural setup sheets (if not on file with the County of Butte).
SFootings--(check.one)
-D I
(in.) (in.)
Max. Pier.
............ ... 5 _ 6 Spacing
• x3p tt. in.
in.)4_
1 I _
2 30
.i (in.) (in.) %� riax.
1 .- 0 Overhang
--- x — in.
*If center piers are other than drawn above, -
draw in locations, spacing, and dimensions.
BUTTE COUNTY ^'
BUILDING DEPARTMENT
APPROVED
/x/
1. Wood either .
A
i
i
pressure treated or
Center
Center Support
fdn.'grade.
Support
Locations
Footing Sizes
(in.)
/
2. Concrete pad.
=)k
243.
Other,`specify
�.in.
in.
Supports (check one;
/x/
1. Concrete block
0
24 x30
2. Concrete piers
ft in1
. (in:) -(in.)
.. ....... .
3. Steel piers
..
........ .... ..
4. Other, specify
...
12 30�
Typical Support
'
. . .24x
x
Footing Size
Y� in .
30
..............
. i )
(in.) (in.)
Max. Pier.
............ ... 5 _ 6 Spacing
• x3p tt. in.
in.)4_
1 I _
2 30
.i (in.) (in.) %� riax.
1 .- 0 Overhang
--- x — in.
*If center piers are other than drawn above, -
draw in locations, spacing, and dimensions.
BUTTE COUNTY ^'
BUILDING DEPARTMENT
APPROVED
1
Y t. COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WO �K
•, 7 County Center Drive — Oroville, California 95965
7 Telephone: 534-4541 / 715' 7�
APPLICATION AND PERMIT
authorize representatives of the County of Butte to enter upon the
above-mentioned property for inspection purposes.
X a`te
Signature of Permitee or Agent
Receipt No. .1+15/ 7
White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant
This permit is hereby issued under the applicable provisions of
the Butte County Code and/or resolutions to do work indicated
above for which fees have been paid.
DIRECTOR OF PI�BLIC WORKS
ding permit expires Date
BUILDING
Owner a o
117 do
SQ. FT. OCC. BUILDING VALUATION
Mailing Ad ress
Te ephone o.
Fireplace
Contractor
Total Valuation
Mai I i ng Address
Permit Fee
Plan Checking Fee &/or Penalty
Telephone No.
Permit Fee
Building Address
PLUMBING No.1 @ FEE
PERMIT FILING FEE $3.00 ,00
7 4' e Lei
Each Trap 1.50
Repair drainage or vent piping 1.50
Water piping Qp
_4
Each gas water heater or vent 1.50
A. P. No` _=f
'Z ZO"
Gas piping system 1 - 5 outlets 1.50
Each additional outlet .30
,rod's
&Wuvon
Fire Dept.
Fire Zone Use Permit
Building sewer
EQA
Parking
Plans
Parcel
Declaration
parcel Ma p
60' R/W
Im r
p ovements
Lawn sprinkler system 2.00
Bldg. dons Recd
Parc proval
PI n Approval
Permit Fee $ 23,(p0
$CC
NEW ❑ ADDITION ❑ UTILITIES OTHER ❑
ELECTRICAL No. @ FEE
PERMIT FILING FEE $3.00
Main service V OR LE
100 AMP ORSLESS 5.00 0
Main service EA. ADD'L 100 AMP 2.50 �®
Single Family ❑ Duplex ❑ Mobil Home EK Others ❑
Main service OVER 600V
100 AMP OR LESS 25.00
Main service/ EA. ADD'L 100 AMP 1.00
3�0 _ �/J�
L -Oe
OR ADDNSNEW T ( DDWELLIN GOCCUP. &) 20sgft
NEW CONSTR MULTI.OUTLET
NON-RESID, ( BRANCH CIRCUITS) 2.50ea
NEW CONSTR. POWER APPARATUS &
NON.RESID, (SINGLE OUTLET CIR.
CONTRACTORS LICENSE LAW
I am licensed under the provisions of Chapter 9, Div. 3, of the
State of California Business & Professions Code under the name
style of:
Ex. Occup(OUTLETS OR FIXTURES)@tea
BALC91
Ex. Occu FIXED APP LNS. OR
p• OUTLETS (RESID.) EA) 2.00
Temporary service 10.00
Mobile Home Facilities 15.00 tg,0p
License No. Classification
Misc. Wiring 6.25
I am exempt from the Contractors License Laws of the State of California.
Permit Fee $
WORKMEN'S COMPENSATION INSURANCE
1 am aware of the provisions of Section3700 of the California Labor
Code which requires every employer to be insured against liability
for Workmen's Compensation.
❑I have placed on file with the County of Butte a certificate of
W •kmen's Compensation Insurance.
1 certify that in the performance of the work for which this
permit is issued I shall not employ any person in any manner
so as to become subject to the Workmen's Compensation Laws of
California.
MECHANICAL No. @ FEE
PERMIT FILING FEE $3.00
Heating
Cooling
Ventilation
Hood 2.00
Permit Fee $
$
I certify that I have read this application and state that the above
information is correct. I agree to comply to all County Ordinances
and State Laws relating to building construction, and hereby
TOTAL PERMIT FEE
$4g C
authorize representatives of the County of Butte to enter upon the
above-mentioned property for inspection purposes.
X a`te
Signature of Permitee or Agent
Receipt No. .1+15/ 7
White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant
This permit is hereby issued under the applicable provisions of
the Butte County Code and/or resolutions to do work indicated
above for which fees have been paid.
DIRECTOR OF PI�BLIC WORKS
ding permit expires Date
"this set of plans
'kept on the lob at all times and it is u wful tot
-
mril•e anv changes or alterations on
written permission from apartment of Public
Works, County of Butte._ -
The Setback shall be 5 ft, fro
the side property line and 50 ftm} n
the centerline of the road, p
a maximum of a 2 ft. eave overhang
0
All utility conrsections shall be
located wi' Hn .4 ft. outside the rear
third section of the mobile home
on the left (road) side of the mobile
home,
Z77..%Z.17_7_-Y: 4:_OC.9T_/_Q/�/S_�.?E_
,:;', 4 -:=_'?F7e-0X:=:NOT-T-O SC,,9CE�
NOM—All Materials , & Workmanship Shall Be 'n
Acrordra�-ce with Rer.minized _ Good- Practices a
'4a act" +,jprercr-bed for the Specified use in the
IIniform Buil"ling, Plumbing & Machanical Codes and
the National Electrical Code.
LOT 13G
UNIT 1
70.0. -
I
D --
TgA. Cz! r
BUTTE COUNTY
BUILDING DEPARTMENT
APPROVED
GO�N—
"-
I'