Loading...
HomeMy WebLinkAbout069-130-021Y ` George R. Miller 515 Silverleaf Dr., lot 171, KR#l, OD Permit 14 9-79P,E�util. ,Ho ELEC. - GAS 7 hof SUPP STRUCTURE REQ. -744) 14 COMPACTION TEST REQ. �Q i Contr: Carneros Mobile Tans ort Permit##2509-79MHI Issued — "7/F; <--_l ` contr: Holmes Mobile Home Serv., Oro., Permit #3723-79B(awning & 1ecks/ NH) Aa'j- aw-&j 'c- JT -c'" - �C�I t�I ------ -�� M � �"' jPERMIT NO. 3723-79B PERMIT EXPIRES !.OWNER George Miller Holmes Mobile Home Serv. Oroville CONTR. LOCATION (A.P. 34-62-21 c 515 Silverleat Dr., lot 171, K01, Oroville e y c Temp. Power Pole Called PG&E Temp. Elea Serv. Called PG&E/rJ Temp. Gas Serv. r�lJ Called PG&E /1 JOB FINALED c (Date (Signature) (NOTE: An entry must be made on this form each time you visit the job site.) COUNTY OF BUTTE — .DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION' RECORD BUILDING BUILDING (Cont'd) PLUMBING Setback [- Firewall Soil Piping Forms Parapets A 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows V 3rd Floor Stemwall Siding To out Slab Roof Sheathing Water Piping Piers Roofing S - . o ���„� Sewer Garage Fdn. Vents Fixtures Footin s Stemwall Garage Vents Insulation Water Htr. Heaters Slab Carport Footings Prov. for ph sically handicapped Conformance of ex. Y I structure Appliances Gas Piping & st Temp. as Slab Final 'Sanitation ' Patio FIREPLACE Final Footings Footing ELECTRICAL Masonry Walls Throat Roucih Reinf. Steel Final Fixtures Bond Beam FIRE SP IN ERS Motors Framing %!- Test Water Htr. Stucco Final Subpanel; Mesh MECHA ICAL Grd. Fault Prot. i Scratch Heating Service Brown Cooling Temp. Pole Finish J Ducts Under roun Interior Lath Ventilation Permanent Door Closer Final Final MOBILEHOME UTILITIES ------------------ Elec. Service Elec. Pedestal Water Piping Sewer Gas Piping 1 EHOME INSTALLATION - - - - - - - - - - - - - - Support Elec. Continuity Water Piping Drainage Gas Piping DATE REMARKS OR CORRECTIONS (NOTE: An entry must be made on this form each time you visit the job site.) COUNTY OF BUTTE -- DEPARTMENT OF PUBLIC WORKS •r 7 County Center Drive .- Orovi lie, California 95965 Telephone: -934-4541 APPLICATION AND PERMIT BUILDING Owner (n I LL C SQ. FT. OCC. BUILDING VALUATION ?t-- z&" Mailing Address a20 Telephone No. Contractor VIc-c- Mailing Address �. C-)Vr Fireplace Total Valuation (o ® .- L — , Telephone o. c _ 8 IQ Permit Fee 9 . Building Address-� _ Plan Checking Fee&/or Penalty Permit Fee -� PLUMBING No.1 @ FEE PERMIT FILING FEE $3.00 Each Trap 1.50 Repair drainage or vent piping 1.50 A. P. NO. r p� �, 2!-,Jng & Planning Water piping 1.50 Each gas water heater or vent 1.50 F 1 Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA Parking Parcel Plans Declaration Parcel Map 60' R/W I Improvements Each additional outlet .30 Building sewer 5.00 pt eld . Ions a cdl// Parcel Approval Plans Approval Lawn sprinkler system 2.00 NEW ADDITION ❑ UTILITIES ❑ OTHER ❑ Permit Fee $ $ ELECTRICAL No.1 @ FEE PERMIT FILING FEE $3.00 Main service 800V OR LESS100 AMP OR LESS 5.00 Single Family ❑ Duplex ❑ Mobil Home Others ❑ Main service EA. ADD'L 100 AMP 2.50 d S,K 41Q2 1, Main service OVER soov 25.00 100 AMP OR LESS Main service EA. ADD'L 100 AMP 1.00 � NEW CONS. I DWELING�( OR ADONST % ACCL BLOGS.CCUP. Y) 20 sq ft CONTRA ORS LICENSE LAW 1 am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name s leo NEW CONSTR. MULTI.OUTL T NON.RESID % BRANCH CIRCUITS) 2.50ea NEW CONSTR. (POWER APPARATUS B NON-RESID. SINGLE OUTLET CIR. Ex. OCcuo(OUTLETS OR FIXTIIRES BAL01 LNS Ex. Occup.( OUTLETS IXED AP(RESID )REA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 6.25 License No. Classification I am exempt from the Contractors License Laws of the State of California. WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. r -1I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. X t Date b 5' nature of Permit or/°_n Receipt No. ` 9� White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant Permit Fee $ MECHANICAL No. @ I FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 1 1 2.00 Permit Fee $ $ Land Development Fee $ TOTAL PERMIT FEE $ This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTO"F PUBLIC WORKS By Date�' Z ?1� B tlding permit expires Date G-7-z—IPO FPERMIT NO. _ 479-79P,E PERMIT EXPIRES OWNER George R. Miller. CONTR. owner 34-62-21 LOCATION (A.P. ) 18 ti 515 Silver.leaf Dr., lot 171, KR#1 , Oroville. I Temp. Power Pole Called PG&E _ Temp. Elea Serv. Called PG&E Temp. Gas Serv. Called PG&E /JOB _ FINALED or?/ (Date (S gnature) grown COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD Tkmp. Pole BUILDING BUILDING (Cont'd) PLUMBING ck \Fs F ewall Ski Piping NInd Permanent Par ets t Floor n Bldg• Rest om Finish 2n Floor otin s Windo 3rd loor St wall Siding To out Slab Roof Sheahing Water PIPNog Piers Roofing Sewer Garage Fdn. Vents Fixtures Footings Garage Vents Water Htr. Stemwal l Insulation Heaters Slab Carport Footings Prov. for physical handica ed Conformance of ex. X structure V Appliances Gas Piping & Test Temp. Gas Slab Final A Sanitation Patio FOE ACE Final Footings Footing ECTRI L Masonry Wall Throat Rou h Relnf. Stell Final Fixtures Bond Be m IRE SPRINKLE Motors Framing Test 01Water Htr Stucco Finat Z Subpanelt I Med MECHANICAL X Grd. F ult Prot. grown I Coo ng Tkmp. Pole finish D is round terior Lath ntllation NInd Permanent oor Closer anal Final MOBILEHOME UTILITIES Elec_ Service Elec. Pedestal Water Piping Sewer L�_5 -���_ Gas Piping E OME INSTALLATION - - - - - - - - - - - - - - SupportElec. Continuity Water Piping Drainage iping DATE `� `�` % oi6 D/¢- REMARKS OR CORRECTIONS ^A6 64-d Al0 576t? (NOTE: An entry must be made on this form each time you visit the job site.) N COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS , .7 COUNTY CENTER DRIVE OROVILLE, CALIF. - 534-4541 CERTIFICATE OF OCCUPANCY This mobilehome has been installed in accordance with the requirements of the California Administrative Code, Title 25,.Chapter• 5, under permit number for the following location: Owner Owner's Address Mobilehome Mfg. Model Year Insignia No. - %'' Serial No. It is hereby certified for occupancy at the above described location and may be occupied. Director of Public Works Date By THIS CERTIFICATE IS VOID WHEN MOBILEHOME IS RELOCATED White - Owner, Yellow - Installer, Pink - D.P.W. 9. Electrical A. Is service large enough.to provide`adequate amperage -to mobilehome (must equal rating of mobilehome with a minimum of 1 amp) and other facilities ori lot, i.e., water pumps, garage, cabana, etc.? Yes No B. Is there proper clearances around panels? Yes C/No C. Is power supply cord or feeder assembly properly fused? Yes C ,,5 D. Isc tinuity test satisfactory as per the following procedure? Yes No L/ De -energize electrical wiring system of the mobilehome at the pedestal. ?Make sure that the power supply cord or feeder assembly conductors, including neutral conductor, have been disconnected.. ,3i' --Switch all breakers and switches in the mobilehome to the "on" position. lar-�—Connect one*lead of a test instrument to the mobilehome grounding conductor and apply the other lead to each mobilehome supply conductor, including neutral. All non-current, carrying metal parts of the mobilehome (aluminum siding, gas line, water line), including fixtures and appliances, shall be tested for continuity from such equipment and the grounding conductor. 4 -. Upon completion of the above procedure, the power supply cord or feeder assembly conductors shall be connected to the site service equipment. A further continuity test shall then be made between the grounding electrode and the chassis of the -mobilehome. Upon satisfactory completion of.theelectrical tests, the lot or site service equipment may .be approved for energizing. 10. Is job card signed by Health Department for water and sanitation? 11. If everything okay, sign off card and tag services. MOBILEHOME DATA Manufacturer. and/or Namestylce Length G Width / Vehicle Serial No. State Identification No. Additional Information or Comments: MOBILEHOME INSTALLATION INSPECTION CHECK LIST 1. Is the mobilehome located withui'red separation from lot.lines and buildings and generally conform to plot plan? Yes No 2. Does the mobilehome have required clearances above ground? (Sec.5085) Yes vNo J 3. Are footings and,supports properly sized, spaced, and braced as pe proved plans? (Note possible variation at spring shackles.) (Sec. 50 2 & 5083). Yes No 4. Is the mobilehome level? (Sec. 5088) Yes' No 5. If more a single unit, are crossover connections properly installed? .(Sec.•5088) Yes o 6. Water A. Is fl�exiblconnector of adequate size and properly installed (1/2" ID min.)? (Sec. 5566) L - Yes o B. Test - Does water piping withstand working pressure or 50 lbs. air test? Yes '", No I&B ckflow.- If coach is not State of California.approved, does station have backflow device nd pressure -relief valve? Yes_ No 7. Wastes and Drains A. Is connection made with Schedule 40 DWV and have flex connectors at each end? Yes — No • v� B. Does it have minimum" per foot slope and is it properly supported? Yes_ No C. Are any leaks detected in drainage system after running 3- llons of water through each. fixture including washing machine standpipe?..Yes No (ISA U coach is not State of California approved, does station have required trap and vent? [" V Yes No 8. Gas Piping and Gas Vents I 1 1. . A. Connector - Is mobilehome connected to the gas s ply with an approved 3/4" minimum mobilehome c nector not more than 6 ft. long? Note: All piping is to be at -least as large as the m ilehome gas line inlet wit t reductions other than the mobilehome connector. Yes No B. Test OK as per followi proce/ek?sNo 1. Open all appliance c ect. 2. Shut off appliance burner valves. 3. Air test with manomete to 1011-M water column, or test with slope gauge (minimum 6oz.-maximum 8 oz.) c ibrated in th pound increments. Test for 10 min. without drop. 4. Connect gas met to mobilehome with connec r, turn on gas, test connections with soapy water. C. Are all appli ce vents properly installed? Yes No COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS • .;�,' 7 County Center Drive — Oroville, California 95965 Telephone: 534-4541 APPLICATION AND PERMIT / BUILDING Owner George R. Miller SQ. FT. OCC. BUILDING VALUATION Mailing AddressS/ 5 L Vim,�C� �%/� Telephone No. c Contractor Carneros Mobile Transport Mailing Address 1290 E1 Capitan Fireplace Total Valuation Telephone No. Napa, CA 94558 707-252-2411 Permit Fee Plan Checking Fee&/or Penalty BuildingAddress 515 Silverleaf Drive Permit Fee Oroville, CA 95965 PLUMBING No.1 @ FEE PERMIT FILING FEE $3.00 Each Trap 1.50 Lot 171, Unit 1 -- Kelly Ridge Estates Repair drainage or vent piping 1.50 Water piping 1.50 A. P. No. 34 — 62 — 21 Zoning & Planning Each gas water heater or vent 1.50 F ..Se,&tatiory Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA Parking I ParcelEach Plans Declaration I Parcel Map 60' R/W Improvements additional outlet .30 Building sewer 5.00 Bldg. PI ns Recd Parcel roval Plan rovaI Lawn sprinkler system 2.00 NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER Permit Fee $ INSTALLATION ELECTRICAL No.1 @ FEE PERMIT FILING FEE $3.00 Main service 600V OR LESS 100 AMP OR LESS 5.00 Single Family ❑ Duplex ❑ Mobil Home Others ❑ Main service EA. ADO'L 100 AMP 2.50 Main service OVER 100 AMPe0ov OR LESS 25.00 Main service EA. ADD'L 100 AMP 1.00 NEW CONST./ DWELLING OCCUR. 4\ OR ADDNS. 1 ACC. BLDGS. 2�sgft CONTRACTORS LICENSE LAW NEW CONSTR. BRANCH CIRCUITS) NON -REBID BRANCH CIRCUITSI 2.50ea I am licensed under the provisions of Chapter 9, Div. 3, of the NEW CONSTR. (POWER APPARATUS a NON-RESID. SINGLE OUTLET CIR. State of California Business & Professions Code under the name Ex. Occup{OUTLETS OR FIXTIIRES B �@ style of: FIXED APLNS. Ex. Occup. (OUTLETSP(RESID.)REA) 2.00 CARNEROS MOBILE TRANSPORT Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 6.25 License No. 259158 Classification C-61 I am exempt from the Contractors License Laws of the State of California. I Permit WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ®I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is. issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. X Date Signa o rmitee o Ag Receipt No. White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant MECHANICAL No. @ PERMIT�FILING FEE $3.00 Heating Cooling Venti lation Hood 1 1 2.00 Permit Fee $ $ t�>?iit4�iiEf� Ml Hm Installation $ 30.00 TOTAL PERMIT FEE I$ 30 00 This permit is hereby issued under the'applicable provisions of the Butte County Code and/or resolutions to do work indicated above which fees have been paid. T OF PUB IC WORKS B . Date � Building permit expires Date 4 _ v MOBILEHO E SUPPORT DATA Mobilehome Mfr. MOUNTAIN VALLEY HOMES If other than single wide, IF furnish Setup Model No. 2 BDR, RK Year 1979 Width 24 (ft.) Box Length 62 (ft.). Tagalong or Expando Size -0- ft. x -0- ft. (SHOW SUPPORT DETAILS BELOW) On all mobilehomes manufactured after October 7, 1973; furnish manufacturer's installation manual and structural setup sheets (if not on file with the County.of Butte). a All center supports measured from front of mobilehome unless otherwise specified. Single D b� (ft.)(in;) Center support locations* (ft.)(in.) (ft.)(in.) (ft.)(in.) *If center piers are other than drawn above,. draw in -locations, spacing, and dimensions. Footings (check one) 1. Wood either pressure treated c foundation grade. 2. Other (specify) Supports (check one) 1: Concrete block. E] 2. Other (specify) Tagalong or Expando, show support details. °J -- Typical Support in.) Footing Size -- Max. Pier Spacing -- Max. Overhang (ft.)(in.) BUTTE COUNTY BUILDING DEPARTMENT APPROVED 0 BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS 7 County Center Drive, Oroville, CA. PHONE: 534-4541 MOBILEHOME INSTALLATION SHEET J 1. Owner's name: George R.'Miller 2. Installers name:, CARNEROS MOBILE TRANSPORT 3. Is the site currently under permit? Yes /x / No (If yes, furnish permit number 479-79P,E ) OR Is the site an existing site? Yes / / No /X / (If yes, furnish two (2) plot plans.) 4. Will -the mobilehome be located at least 5 ft. away from septic tank and leach fields and clear of all setbacks and easements? Yes /X / No (If no, clarify 5. What is the mobilehome electrical rating? ----------------------- 6. What is the mobilehome site service rating? ------------------ ---- 7. What is the mobilehome site circuit breaker rating? ------------- 8. Is there any other electric load to be served by the mobilehome, site service? --------------------------------------------------- Yes / / (If yes, identify the load and size: (Load) 200 Amps 200 Amps 200 Amps M No /1X/ _(Amps) 9. What is the mobilehome site gas pipe size? -----------=---------- -0- (in.) 10. What is the type of gas service? ----------------------------- Natural / / LPG / X/ 11. What is the gas pipe length from meter or tank to the mobilehome? -0- (ft.) 12 What is the mobilehome gas demand? -------------- -0- (BTU) (This information not required if pipe length less than 6 ft. on natural gas or less than 50 ft. on LPG.) �+ COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 Telephone: 534-4541 APPLICATION AND PERMIT authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. AS X Q A ) Date 17 SignatuL of�Perpmitee or Agent Receipt No. . - � 3 R-1 White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTO PUBLIC WORKS 4 6 By Date Building permit expires Date BUILDING Owner George R. Miller SQ. FT. OCC. BUILDING VALUATION Mailing Address 3729 So. Quincy Place Kennewick, Washington 99336 Telephone No. 509-582-4803 Contractor OWNER Mailing Address Fireplace Total Valuation Telephone No. Permit Fee Building Address 515 Silverleaf Drive Planng Fee&/or Penalty Permit t Fee Oroville, CA 95965 PLUMBING No.1 @ FEE PERMIT FILING FEE $3.00 ,00 Each TraD 1.50 Lot 171, Unit 1 --Kelly Ridge Estates Repair drainage or vent piping 1.50 A. P. No. 34 - 62 - 21 ing & 1Pla ing ater piping 1.50 D.00 Each gas water heater or vent 1.50 F W S n Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA P arking Plan - Parcel Declaration Parcel ap 60' R/W Improvements Each additional outlet .30 Building sewer 5.00 0.00 Bldg. Pk ns Recd Parcel A roval PI Approval Lawn sprinkler system 2.00 NEW ❑ ADDITION ❑ UTILITIES OTHER ❑ Permit Fee $ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 3.0a Main service 100V OR L 00 AMP ORSLESS 5.00 5,0C Single Family ❑ Duplex ❑ Mobil Home Others ❑ Main service EA. ADD'L 100 AMP 2.50 u Main service OVER 25.00 100 AMPP OR LESS O . Main service EA. ADD'L 100 AMP 1.00 NEW CONSDWELING OR ADDNST i ACCLBLDGS.CC UP. 20sq ft CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: NEW CONSTR. UL-11-0UTLET NON.RESID BRANCH CIRCUITS) 12.50ea NEW CONSTR. (POWER APPARATUS 6 NON.RESID. SINGLE OUTLET CIR. Ex. Occup {OUTLETS OR FIXTURES B L01 Ex. Occup.01 FIXED APPLNS. OR OUTLETS (RESID.) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 �. License No. Classification Misc. Wiring 6.25 am exempt from the Contractors License Laws of the State of California. Permit Fee $ 0l5 S $ a.% -S -Z MECHANICAL No. @ FEE WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑I have placed on file with the County of Butte a certificate of Wo en's Compensation Insurance. certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood J 2.00 Permit Fee $ $ I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Land Development Fee $ TOTAL PERMIT FEE $ 1 authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. AS X Q A ) Date 17 SignatuL of�Perpmitee or Agent Receipt No. . - � 3 R-1 White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTO PUBLIC WORKS 4 6 By Date Building permit expires Date NOTE:--AII'Materials & Workmanship Shall Be in LOT 171 Accordance with Recognized Good Practices and UNIT 1 of a quality prescribed for the Specified use in the Uniform Building, Plumbing & Machanicall Codes and N�TiV; fi�OME the National Electrical .Code. this set of plans and sp kept on the job at all times make any changes or alterai written permisson from the Works. Countv of Ft,,++ - Septic system and location a ttobeal Butte County Health Dept. quirements. O IN ]Y+0—ns MUST be side property line and 50 tt. from the it is' unlawful to centerline of the road, permitting .a maxi - 3n cArn. ' - ,—mum of a,2 ft. eavP overhang but entirely t All utility connections shall tLE located within 4 ft. outside the reao third section of the mobile home on the left (road) side of the home. molhilP0 Q ETI3/-E Gf_f= L3T A'Ci< 7 75% t3UTTE COUNI Y ,AV o_T� — BUILDING DEPARTMENI L0CA77/O�/3 f12E _ APPl20X, 07- TO. SCALE,_._.... APPROVED _�/ti70B/L E i9DOCI� /-9- 79 /2l/�' i I� IN ID k 1%✓.4GL`:-- o L3T A'Ci< 7 75% t3UTTE COUNI Y ,AV o_T� — BUILDING DEPARTMENI L0CA77/O�/3 f12E _ APPl20X, 07- TO. SCALE,_._.... APPROVED _�/ti70B/L E i9DOCI� /-9- 79 /2l/�' C Q 0 K ASSOCIATES James Glander Department of Public Works 7 County Center Drive Oroville, California 95965 ENGINEERING CONSULTANTS 2060 PARK AVENUE OROVILLE. CALIFORNIA 95965 PHONE (916) 533-6457 CAI.IFORN�A P. F. NEVADA P. t, OREGON P. L•'. March 15, 1979 Re: 78551 Dear Jim: We are pleased to submit the enclosed Report on Controlled Compacted Fill for: Miller KRE Unit 1 Lot 171 If you have any questions, please do not hesitate to call. Very truly yours, COOK ASSOCIATES Lew Hiatt Civil Engineer LH/cab Enclosures DR. LLOYD M. COOK ED, D. JOE E. COOK M. E. DAN J. COOK C. E. CO ® KASSO w ENGINEERING CONSULTANTS 2060 PARK AVENUE OROVILLE. CALIFORNIA 95965 PHONE (916) 533-6457 March 15, 1979 REPORT OF CONTROLLED COMPACTED FILL PROJECT: Kelly Ridge Estates Lot 171, Unit' 1 Miller Re: 78551 GENERAL Compacted.fi.11 was placed to provide support for a mobile home. The maximum depth of compacted fill is about four feet. DESCRIPTION OF FILL Prior to placement of structural fill, the area to receive fill was cleared of weeds and debris. The material used for the. fill was imported to the site and consisted of gravelly silty sand. Structural fill was placed in loose layers about six inches in thickness and compacted by track rolling. During construction of the mobile home pad, fill was placed outside the structural fill. This fill was not tested during grading and is considered to be a nonstructural fill. A typical cross-section (plate 1) depicting this condition is attached. The approximate extent of the grading is shown on the attached drawing "Location of Density Tests". TESTING Field density tests were taken at frequent intervals near the fill surface. A representative sample of the soil was taken to the.laboratory for compaction tests. The relative density of the fill was determined from the compaction test. OR, Lt -0 1'D F.. _.. D. JGff E ._..:"K to F. part J. C'Q0K C = . The location of the field density tests are shown on the attached drawing. The results of the tests are presented on the table "Summary of Tests". CONCLUSIONS Based on intermittent observation, it is concluded that the structural fill was placed in an orderly and efficient manner and that the field density tests are representative of -the structural fill. It is.our opinion that all portions of the structural fill are compacted to at least 90% of the maximum density, in accordance with the requirements of the County of Butte. COOK ASSOCIATES By Lew Hiatt Civil Engineer RPL/cab SUMMARY OF TESTS PROJECT: Kelly Ridge Estates Lot 171, Unit 1 Miller Re: 79551 FIELD DENSITY TESTS: Field Test Density Percent Maximum Degree of .No. Date Elev. pcf Moisture Density .Compaction Remarks 1 3-8-79 1'Fill 121 10 133 91 . .2 3-8-79 2'Fill 126 10. 133 95 3 3-14-79 3'F ill 129 15 133 97 4 3-14-79 4'Fill 128 12 133 96 '5 3-14-79 4'Fill 123 13 133 92 COMPACTION TEST: Maximum dry density, pcf: Maximum size tested: Optimum moisture, percent: Soil type: 133 3/4" 8 Gravelly Silty. Sand .. LOT 171 LOCATION OF ,DENSITY TESTS UNIT 1 ./LLE2 N7 TN, h'O ME� G LEGEND 19' �, W 2-00-,9MP__ Limit of Tcsted i Fill . Locdtion vF ° I N 2 �I D ' n5ity TQst.io Q Depth of Fill in ft. SC Fill Slope,��' `9 V II I 2ETAIIV/n/G N 15 't Y" I /o' I 172A7it/: E.gS�iv1ENT // O T_c APPf20.Y" -NOT TO SCALE. 6.4-/S -73 TYPICAL CROSS SECTION Not To Scale RE: 79 S5I BUILDING SETBACK LINE 1•-1®11n11 .nn w nf- cc LASSOCIATES 'F - ENOWEEQ40 CONSULTANTS IIOeD? 4' -PARK' AVENUE OPOVLL.LE . CALIFORNIA " ewes URAL PLATE I