Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
069-140-025
^ ` � * \ � . ` . , ' o 'COMPACTION TEST �contr:Carneros- iile �Tians�port, Napa11Permit 7 5,4Issued 7 J� . ' P it #5829-76B(new awning/MH)� �Ze o � contr: Holmes Mobile Home S.erv., BangorPermit #283-77?,1(n6w awning & decks/MH)� 69-14-25� ^ Contr: Middlefork' Const 1104 IS.| \ � ./ . � . � " . . � ^ � �--�' r —?- -`- ' ~ ' �K ' — � ^ ' | �o5 ° v PERMIT NO. _ 3533-83B PERMIT EXPIRES 10" 261" OWNER DON ASHCRAFT CONTR. M,ddlefork Const ASSESSOR PARCEL 69-1425 LOCATION _108 Kristee Place, Oro Temp. Power Pole Called PG&E Temp. Elec. Service Called PG&E Temp. Gas Service Cal led PG&E JOB FINALED (Date)— I Signature V. = OK O = Not OK Not Applicable MOBILEHOMES * = Not Ready MISCELLANEOUS Date MOBILEHOME UTILITIES (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except N's' 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support -Sketch _ 2. Footings; Size -Depth -Spacing -Connectors 3. Sewer; Location -Test -Fall -C/O -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4. Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Bracing__ 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; LocatiorrTest-Wrap:/ /"L"ft./ /"Nat. or/ /"L"ft./ /"LPG 6. Carports: Windows -Doors 7. Utility Clearance 7. Elec. v Card -BI Card -BI Date Card -BI Date Date Card -BI Date Card -BI Card -BI Date Card -BI Date Date Card -BI Date Date MOBILEHOME INSTALLATION (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Date _ POOLS (Plans) OK except #'s 1, Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH Test -Demand -Valve -Connector 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining__ 4. Electricity; MH Test -Crossovers -Breakers -Clearances 4. Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test -Fall -Flex Connector 5. Elec.; Pool Lighting; 15 volts-GFI 6. Water; MH Test -Regulator -Connector 6. Elec.: Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/O to Grade -HD Approval 7, Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 8. Elec.; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main in Conduit 10. Cert: of Occupancy 9. Health Department Approval ^ 10. Plumb; Cir. Test -Water Supply Test Card -BI Date Card -BI Date Card B -I Date Card -BI Date Card B -I Date Card -BI Date Card -BI Date Card -BI Date J = OK 0 = Not OK - = Not Applicable RESIDENTIAL (Single and Duplex) ' = Not Ready Date UNDERFLOOR (Plans) OK exce t#'s Date FRAMING (Continued) oning requirements -Setbacks -Easements - I -Flet. Grnd.- / /" Ftg. Depth 48. 49. Property Line Firewall & Openings Ext. Doors -One 3' -Check Garage -3rd story, 2 exits Garage; Soils -Steel- / " Ftg. Depth 50. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection g., P ches &Decks; Soils -Steel- / /.5(,_Ftg. Depth 51. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 52. Siding -Nailing -Veneer 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access 7,41111 lace Ftg.-Steel 54. Glazing Area -Glass Protection -Skylights -Plastic _ 8. 9-.W.V.., '' Fittings -Test -2 way C/O -Sewer Test 55. Shear Walls; Nailing -Bolts _ 9. ize-Anchors 10. Ws4@r+4p- ;._Test -Anchors -Regulator -Service Test 11. r round 12. Rtenvm,&- -IIucts; Clearance -Material -Support -Ins. 13. &a_Anchor Bolts -Joists -Vents -Cripples Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date BI - ate/ .i7 Card -BI Date Date FINAL (Plans) OK except N's C3�.81' Date/ Card -BI Date Date LUMBING (Permit) OK except p's 56. Ext. Steps -Door & Sidelight Protection -Landings 57. Smoke Detector 14. Ht.; Vent -Access -Combustion Air 58. Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection _ --Water 1 'Water Pipe; Test & Anchors -Nail Protection D.W.V.; Test-Fttngs &Anchors -Nail Protection 59. Bedroom Exiting 116. 17. Shower Pan; Test, First Floor -Tub Access 60. G.F.I. & Bath Fixtures & Tub Access 18. Test Tub & Shower, 2nd Floor -Tub Access 61. Elec. Trim & Subpanel; Breaker Sizes -Labels _ - 19. Gas Pipe; Size & Anchors 62. Stairs & Rails 63. Fireplace or Stove; Clearances -Hearth 64. Elec. Outlets at Wood Panel; Int. & Ext. Card -BI Date Card -BI Date 65. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance Card -BI Date Card -BI Date 66. Elec. Outlets & Receptacles at Kit. Counter Date <ECTRICAL Permit OK except k's 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper -- 20. Fixture & Transformer Clearance -Ins. Protection 69. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 21.!Size Receptacles Spacing -Lights &Switches at Doors 70. Plb., Elec. & Mech. Equip. Listed for Location _ 22. Size Boxes & No. of Conductors -Stapled 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. - 23. Romex Installed Close to Edge of Studs & C.J. 72. 73. Insulation -Foam -Looked in Attic ❑Yes Guard Rails &Deck Construction -Post Caps 24. Equip. Ground made up w/Mech. Fasteners -Bond Gas &Water 25. 2 Appliance Circuits in Kitchen & Conductor Size 74. Fdn. Vents &Crawl Hole Door -Drainage &Wood -Earth Clearance Looked under Floor ❑ Yes _ 26. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 27. 28. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al, Insulated Neutral � ;Yes [D No Service -Riser Conductors & Ground -Main Disconnect 75. Following instld.: Drive [I Yes ❑ No; Walks E] Yes E] No; Planters 11 Yes CJ No 76. Stucco; Brown -Finish -- 29. Equip. Clearances; Panels-Motors-Mech. Equip. 77, 78, 79. A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. Water Well; Disconnect, Electrical, Plumbing 30. Clothes Closet Light -Shower Light _- Card B-1 _ _Date _- Card -BI _-- Date Card B-1 Date Card -BI Date Date MECHANICAL (Permit) OK except N's 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground 81. 82. Ventilation throughout House Glass Protection _ 83. Corrections from Previous Inspections 84. 85. Gas Test -Meters Tagged; Gas -Electric Water & Sewer Connected -C/O to Grade -HD Approval A.C_. Ducts; Insulation & Support - _ _ _31._ 32. 33. Vent Fan; Exhaust above Insulation Condensate Drain _& Overflow; Size & Grade 86, Energy Compliance Certificate -Other Certificates 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet 35. Attic Access & Platform if Furnace in Attic Card -BI Card -BI ----- ---_- -- ------___ _-- --------_-_-_- Date - Card -BI Date Date Card -BI Date Card -BI Date / and -Bl Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date FRAMING(Plans) OK except k's Comments at Final: 36. Sills; Proper Material & Anchors 37. Walls: Studs -Nailing, Spacing & Bracing -Plates -Sound 38. Bearing Walls over Girders & Floor Nailing___ _ 39. Draft Stop in Walls (rat proof) 40. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 41. 42. 43. 45 46. 47. Header .&-Size & Bearing Hangers -Post Caps -Anchors -Connectors Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthnq.-Rfnp. replace Ties or Type A Flue -Fireplace Throat Atti ccess: Size &Rm oex Protection -Draft Stop -Ins. Baffles _ Bdrm. Windows or Exiting Doors -Sill H_gt. & Dimensions__ _ Garage Fire Protection Framing - (NOTE' An entry must be made each time youvisit jobsite) J f - COUNTY OF BUTTE - D9PARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 APPLICATION AND PERMIT PERMIT NO. ASSESSOR ME), MBER„ 'C7.-,5 ZONING BUILDING PERMIT Ow R �o ,4s/�e,e,��T TELEPHONE SO FT. OCC. BUILDING VALUATION o o. �.0 OWNER'S MAILING ADDRESS C/_/ IY!/ O N M E 4 / T CONT ACTOR'S MAILING PDDRESS/�, �Fireplace CONSTRUCTION LENDER 01 UNKNOWN Total Valuation $ i27v Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ 00. &0 ARCHITECT OR ENGIN R LICENSE NO. Plan Checking Fee $ 0,0Z) Penalty $ ARCHITECT OR ENG( EER'S MAILING ADDRESS Permit fee $ QQ,� BUILDIJ0 ASRESS % j� // /V/ PLUMBING PERMIT FiIin g Fee 10.00 Each Trap 2.00 Solar Water Heater 20.00 r/ Water piping 5.00 LOT NO. SUBDIVISION NAME I PARCEL MAP — j— Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTURE SF ❑ Duplex ❑ Mobi lehome ik Other SPECIFY Building sewer5.00 Mobile Home S G W 110-00ed TYPE OF WORK New ❑ Addition Remodel Utiliti ❑ Instpall�tion Other ❑ Describe work: �C Mv� Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. DWELLING OR ADDNS. ACC. BLDGO 2/20sq ft CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check One): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code nd my license is in full force and effect. License No. .9Classification _p ❑ 1, as the ow er, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR TI.OUT T NON -RES,.. CIRCUITS.2.50 ea NEW CONSTR (POWER APPARATUS &) NON-RESID, (SINGLE OUTLET CIR. EX. Occup(OUTLETS OR FIXTJJRES eA ®30 FIXED APPLNS. OR EX. OCCUp. OUTLETS (RESID.) EA.1 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor MECHANICAL PERMIT Filing Fee 10.00 WORKMEN'S COMPENSATION INSURANCE I declareder penalty of perjury (check one): ,The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. No 2eto Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabi ities, judgments, costs, and ex nses which may in any way accrue against id County in copse uence of a granting of this permit. X Date © IL Signature of Appl' ant - Owner ntracror� Agent ❑ An OSHA permit is required for excavations over 5 0' deep and demolition or construct- stories in height. ion of structures over 3�or Mobile Home Installation Fee $ TOTAL PERMIT FEE $ OCCUP. GROUP I TYPE OF CONST, PARCEL PD HD ISSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIREC OF PUBLIC By P MI EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date /o- Zf - 1?y t/ Receipt No. 7 1 / 0 WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT I COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE; CALIFORNIA 95965 - TELEPHONE: 916/534-4541 PERMIT APPLICATI;ON DATA SHEET Permit No. OWNER/VJ AS �Cr �T / A. P. No. �`� Proposed Building Use r 1('-,444b10;_1_ Permit Fee Based Upon: (Comp) to C/ontr ct Price DPW Valuation Othed ( x i ) 1___� Building Inspector Date /4-12 XT At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED APPROVED 1. All items have been submitted. . . . . . . . . . . . 2. Plot plans in duplicate./triplicate. . . . . . . . . . . 3. Complete plans in duplicate. /triplicate. . . . . . . . . 4. Complete engineered plans and calcs. . . . . . . . . . 5. Plans with Energy Design Compliance Statement. . . . . . 6. State Energy Forms No. 7 Statement of Intent for Non -Heated and AC Buildings. 8. Fees of $ . . . . . . . . 9. Letter of signature authorization. . . . . . . . . . . 10. Sanitation approval from Health Dept. 11. Planning approval for (A) Use: (B) Parking: 12. Certificate of Workmen's Compensation Insurance. . . . . . 13. Contractor's License Information (no., name style, classif.) 14. Owner -Builder Verification (Given to owner, Mail to ownerEl) 15. Improvements may be required. . . . . . . . . . . . 16. Mobilehome Installation Data. . . . . . . . • Pro -Inspec. request to 17. Pre -Inspection for Required. Building Inspector (Dote) 18. Other When you issue the permit, process as follows: Mail to owner. Mail to contractor. Telephone and/ho�for pickup atoffice. Deliver w/inspector. Other Appl ican Copy of plans sent Health Dept., Fire Dept,, Other Date During the plan checking process, the following data must be submitted prior to permit issuance: (For required items not checked above at time of application, circle item.) 1. Index permit for above Items No. 2. Additional items required: (Contractor, Designer, Owner) was advised of above required data by Telephone Mail Other Date Plans checked by Date Plans approved by Date Other: Copy—DPW 4 Ag -6 �/Z BOG✓� /Y s w�v �MHUTIL. c x r —� f" f %�%, viy i y /d SG�vG�� 4906-75 P,E PERMIT NO. O 'WG r P E M -+MH UTIL. PERMIT NO. PERMIT EXPIRES OWNER George Sleeter owner CONTR. ;LOCATION (A.P. 34-61-25 ) 108 Kristee Place, Lot 229, KR #1, Oroville 4 i J " Temp. Pow Pole Calle G&E Temp. ec. Serv. Ca ed PG&E fDZ'-u/%(o Tem Gas Serv. ailed PG&E J B /N . //0' o INALED (Date) (Signa re Setback Forms ,Main Bldg. Footings Stemwal I Slab Piers Garage Footings Stemwa I I Slab Carport Footings Slab Patio Footings Masonry Walls Reinf. Steel Bond Beam Framing Stucco Mesh Scratch Brown Finish Interior Lath Door Closer DATE COUNTY OF BUTTE — DEPARTMENT °bF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) PLUMBING Firewall Soil Piping Parapets 1st Floor Restroom Finish 2nd Floor Windows 3rd Floor Sidina To out Roof'Sheathing Water Piping Roofing Sewer Fdn. Vents Fixtures Garacie Vents Water Htr. Prov. for physically handicapped Heaters Appliances Conformance of ex. structure Gas Piping & Test Temp. Gas Final Sanitation FIREPLACE Final Footing ELECTRI( Throat Rough Final Fixtures FIRE SPRINKLERS Motors Test Water Htr. Final Subpanels MECHANICAL _ Grd. Fault Prot. Heating Service Cooling Temp. Pole Ducts Underground Ventilation Permanent Final Final REMARKS OR CORRECTIONS �„('�rct�,ayV.'^"��n ►.e,�^�: "Vr`��w'i :#Y'v�IR7'�^�„ � �' .y, `' �Y� p. COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 7 COUNTY CENTER DRIVE OROVILLE, CALIF. - 534-4541 CERTIFICATE OF OCCUPANCY This mobilehome has been installed in accordance with the requirements of the California Administrative Code, Title 25, Chapter 51 under permit number 5_4757- %L fo the following location: Owner 1 O� e �- Owner's Address Lu Mobilehome Mfg. MOYI /4'�1 �/,,y Model 3 Year 7C Insignia No. 6 f 346 3 Serial No. Z 3 S 7 It is hereby certified for occupancy at the above described location and may be occupied. Director of/Public Works Date /0 ” ZC> Ze By THIS CERTIFICATE IS VOID WHEN MOBILEHOME IS RELOCATED 9.' Electrical A. Is sel-Vice large enaiigl. to provide adequate amperage to mobilchome. (must equal rating of rnobi.lehome'ivith a ::;irib-lum of 100 amp) and other facilities on lot, i.e., water pumps, garage, cabana, etc.? Yes 1�. Is there proper clearances around panels? Ye - No C. Is power supply cord or feeder assembly, properly fused? Yes_ D. Is continuity te:t satisfactory as per the following procedure? Yes _No_ 1. De -energize electrical wiring, syste:a of the mobilehome at the pedestal. 2. D1ake sure that the power supply cord or feeder assembly conductors, including neutral conductor, have: been disconnected. 3. Switch all breakers and switches in the mobilehome to the "on" position. 4." Connect one lo,.. -id of a test insr.rument to the mobilehome grounding conductor and ,T,_,......_ pp'Y ' apply Llie OiU.e1 .l.Cdll l.0 eauil rl1U U L.LC ILUIIIL' $11 1 CUf1LLUC tUL, 1llu U(11h� ILC L1LYdl. 5. All nor. -current, carrying metal paras of the mobilehome (aluminum siding, gas line, water line), including fixtures and;appl.iances, shall be.tested for continuity from such egv.ipment and the grounding conductor. 6. Upon completio-n of: the above procedure, the power supply cord or feeder assembly conductors shall be connected to the site service equipment. A further continuity te:;t shall then be n.ade between L.he grounding electrode and the chassis of the 111.0bilehome.. Upon satisfactory completion of the electrical tests, the lot or site service equipment may be approved for energizing. ra Is job card signed by health Department for water and sanitation? 11. If everything okay, sign off card and ta; s,,erviees. MOBTLLMML_DATA Manufacturer and/or Names tyle LengthWidth2:J_ Vehicle Serial No. State Identificat.i..on b/ 4�3 1.AIitional Information or Cormnents: 'MOBT1,"EHO•tE INS'LALLATBR)P INSPECTION CHECK LIST 1. Is the mobilehome located wil:h -required separation from lot lines and buildings and generally conform to plot plan? Y(nj `—1o ?. Doe the mobilehome have required clearances above ground? (Sec.5085) Yes` No 3. Are footin,s and supports properly sized, spaced, and braced as per approved plans? (Note possible variation at spring shackles.) (Sec. 5082 & 5083) Yes �No 4. Is the mobilehome level.? (Sec. 5088) Yes"' No+ 5. If more than a single unit, are crossover connections properly installed? (Sec. 5088) Yes L_ -No 5, Water A. Is flexible connector of adequate size and properly installed (1/2" ID min.)? (Sec. 5566) Yes N B. Test - Does water piping withstand working pressure or 50 lbs., air test? Yes 4 --No C. Backflow - If coach is not State of California approved, does station have backflow device and pressure -relief valve? Yes_ No�P/I/ 7. Wastes and Drains A. Is connection made with Schedule 40 DWV and have flex connectors at each end? Yes Flo B. Does it* have minimum ," per foot .slope and is it properly. supported? Yes 4---N—o C. Are any leaks detected in drainage system after running 3 -gallons of water through each fixture including washing machine standpipe? Yes No A' D. If coach is not Sta e of California approved, does station have required trap and vent? NAlYes o`P 8. Gas Piping and Gas Vents A. Connecto - Is mobilehome connectedto the gas supply with an approved 3/4" minimum mobilehom connector not more tha 6 ft. long? Note: All piping is to be at least as large as th mobile_home gas line inlet without reductions other than the mobilehome connector. Y6s No B. Test OK as per fo owing proEedure? Yes No 1. Open all applia ce conpector valves. 2. Shut off appliance 6rner and pilot valves. 3. Air test with ma mete to 10"-14" water column, or test with slope gauge (minimum 6oz.-maximum 8 z.) call rated in tenth pound increments. Test for 10 min. without drop. 4. Connect: gas Xfieter to mobilet me with connector, turn. on gas, test connections with soapy wate \ C. Are all appliAnce vents properly installed? Yes No 0 COUNTY OF BUTTE — 12EPARiTMENT OF•"PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 Telephone: 534=4541 APPLICATION AND PERMIT authori representatives of the County of Butte to enter upon the t above ntioned pro y f r i ' X te Signature of Peer''mitee or Agent Receipt No. White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for" which fees have been paid. DIRECTOR OF PUBL4IC WORKS By b/� Date §16461 ig permit expires Date o 1 BUILDING Owner ✓ SQ. FT. OCC. BUILDING VALUATION Mailing Address/ - 0-, 670, / ' Telephone No. / _r5.6 rP73 Fireplace Contractor , Total Valuation Mailing Address .Permit Fee Plan Checking Fee &/orPenalty Telephone No. Permit Fee Building Address PLUMBING No. @ FEE PERMIT FILING FEE $3.00 3,05 Each Trap 1.50 �% / ,Z` Repair drainage or vent piping 1.50 Water piping % "o C) Each gas water heater or vent 1.50 A. P. No - �- ani Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 F V&/ qty® 'phi Fire Dept. Fire Zone Use Permit Building sewer QrUU Parking EQA Plans Parcel Declaration Parcel Map R/W Improvements Lawn sprinkler system 2.00 Plan Recd (60' Parcel Approval T Plans pproval Permit Fee $ a3 c NEW ❑' ADDITION ❑ UTILITIES OTHER [:]ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 too Main service incl. 1 meter , pv Additional meters, each 1.00 Sub -panel (12 or less) (more than 12) - Single Family ❑ Duplex ❑ Mobil Home Others ❑ Range, Cook=top or Oven 1.00 Water Heater or Space Heater 1.00 Light fixturesy �2 10 Receps., switches & fix outlets CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: • Hood,.Ex. Fan or F.A. Furn. Motor. 1.00 Evap. cooler, gar. disp. or D.W. 1.00 Air conditioner or heat pump Water pump . Mobil Home Facilities 5.9,p(7 Temp. Power Pole 5.00 License No. Classification Misc. wiring am exempt from the Contractors License Laws'of the State of California. Permit,Fee $ a- $ MECHANICAL No. @ FEE WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. 0 IWhave placed or file with the County of Butte a certificate of orkmen's Compensation Insurance. certify that in the performance of the work for which this permit ,is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to buildinq construction, and hereby TOTAL PERMIT FEE $ authori representatives of the County of Butte to enter upon the t above ntioned pro y f r i ' X te Signature of Peer''mitee or Agent Receipt No. White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for" which fees have been paid. DIRECTOR OF PUBL4IC WORKS By b/� Date §16461 ig permit expires Date o 1 COUNTY OF BUTTE — QEPAF3TMENT OF PUBLIC WORKS 7 County Center Drive' - Urbville, California 95965 ` Telephone: 534�4541 /C(J, APPLICATION AND PERMIT authorize representatives of the county of Butte to enter upon the above-mentioned property for inspection purposes. ZX Date na e o rmitee r A t Receipt No. White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. �.DIRECT0 OF PUBLIC WORKS By"�--�— Dateb' 7G permit expires Date BUILDING Owner George Sleeter SQ. FT. OCC. BUILDING VALUATION Mailing Address Lot 229, Unit 1 Telephone No. Fireplace Contractor Carneros Mobile Transport Total Valuation Mailing Address 1290 E1 Capitan Permit Fee Plan Checking Fee &/or Penalty Napa, California 94558 Tete y2n 4q.1 Z Permit Fee $ Building Address 108 Silverleaf Drive PLUMBING No. @ FEE PERMIT FILING FEE $3.00 Oroville California 95965 Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 Each gas water heater or vent 1,50 A. P. No. 34-61-25 Zoning & Planning Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 Fe - tti-tet+ Fire Dept. Fire Zone Use Permit Building sewer 5.00 EQA Parking Plans Parcel Declaration Parcel Ma Pte- 60' R/W Improvements P Lawn sprinkler system 2.00 Bldg. Plans Recd Parcel App{olal Plapproval Permit Fee $ $ NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER ELECTRICAL No.1 @ FEE PERMIT FILING FEE 1 $3.00 INSTALLATION a, -Z. &n7,- 4# �� Main service 6000V OR 0 AMP OR LESS 5.00 Main service EA. AOD•L too AMP 2.50 Single Family ❑ Duplex ❑ Mobil Home ® Others ❑ Main service 100 OVER EAMP OR LESS 25.00 Main service EA. ADD'L 100 AMP 1.00 NEW CONST. ODWELING R ADDNS. ( ACCLBLDGS,CCUP. &) 22sgft NEW CONSTR. (MULTI -OUTLET NON-RESID. BRANCH CIRCUITS) 2.50ea NEW CONSTR. (POWER APPARATUS & NON-RESID• SINGLE OUTLET CIR, CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: Carneros Mobile Transport Ex. Occup(OUTLETS OR FIXTURES) 50 0 25o 109 Ex. 0ccuFIXED APP LNS, OR P• OUTLETS (RESID,) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No. 259158 Classification C-61 Misc. Wiring 6.25 ❑ 1 am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. a1 have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I. certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Mobile Home Installation 30.00 TOTAL PERMIT FEE $ 30.00 authorize representatives of the county of Butte to enter upon the above-mentioned property for inspection purposes. ZX Date na e o rmitee r A t Receipt No. White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. �.DIRECT0 OF PUBLIC WORKS By"�--�— Dateb' 7G permit expires Date 0 - PERMIT NO, PERMIT EXPIRES ZZ2 OWNER George Sleeter CONTR. Holmes Mobile Home Serv., Bangor LOCATION (A.P. 34-61-25 108 Kristee Place, lot 729, KR#l, Broville 283-77B Temp. Power Pole Called PG&E Temp. Elec. Serv. Called PG&E Temp. GasServ. Cal ed PG&E 000 JOB FINALED (Date 9, ez,, 4 � C (S gnature) (NOTE: An entry must be made on this form each time you visit the job site.) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) PLUMBING Setback Firewall Soil Piping Forms Parapet 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor StemwalI Siding To out Slab Roof Sheathing Water Piping Piers Roofing Sewer Garage Fdn. Vents Fixtures` Footin s Stemwa l I Garage Vents Insulation Water Htr. Heaters Slab Carport Footings Prov. for phy haodica sic ally ed Conformance of ex. structure A liances Gas Piping & Te Temp. Gas Slab Final ' .� r%'f ` Sanitation Patio FIREPLACE Final Footin s Footing ELECTRICAL Masonry Walls Throat Rough/ Relnf..Steel Final Fixtures Bond Beam FIRES RINKLE Motors Framing Test Water Htr. Stucco Final ''^J Subpanels Mesh utrHANIrAl Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final REMARKS OR CORRECTIONS 1\ 4,leo c/A/ V4 a 404SL I UC (24/V7, 5 Pf JCF �0 ves �! �� i� X3041�ei���so (NOTE: An entry must be made on this form each time you visit the job site.) COUNTY OF BUTTE — DE15ARTAiIENT OF PUBLIC WORKS 7 County Center Drive — OroviIle, California 95965 Tel epho.,6 x'534 4541 a4-1, APPLICATION AND PERMIT duinonze a rese tauves or me county or tsutte to enter upon the above -me 'one ropertVriection purposes. X Date Sig ture of Permite.+e or Agent Receipt No.� 1--2 / White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF BLIC WORKS 71 BY Date 7 7 BLXding permit expires Date /— 7 LT/ —7rP BUILDING Owner �Q' a �� a2>? P� SQ. FT. OCC. BUILDING VALUATION OuD� — © .o-4 Mailing Address Telephone No. Fireplace Contractor hi475 j�' Q Total Valuation Mailing Address, P0. 49X Permit Fee Plan Checking Fee &/or Penalty 0/ Telephone No� Z $ Permit Fee Building Address /Qc PLUMBING No.1 @ FEE PERMIT FILING FEE $3.00 Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 Q .� Each gas water heater or vent 1.50 A. P. No. �� Zoning & Planning Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 Fe W. n ire Dept. Fire Zone Use Permit Building sewer 5.00 EQA Parking Plans Parcel Declaration Pa el Ma P 60' R/W ImprovementsLawn sprinkler system 2.00 Bldg. Plans Recd arcel Approval PI(6s Approval Permit Fee $ $ NEW ® ADDITION ❑ UTILITIES ❑ OTHER ❑ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Main service 80000 AMP ORSLESS 5.00 Main service EA. ADD'L 100 AMP 2.50 Single Family ❑ Duplex ❑ Mobil HomeOthers ❑ OVER 600V Main service 100 AMP OR LESS 25.00 Main service EA. ADO'L too AMP 1.00 ��,n �i �+� Yw �i(/ /J NEW CONST. DWELLING OCCUP. & OR ADDNS. ACC. BLDGS. ) 2�Sq ft NEW CONSTRMULTI-OUTLET NON-RESID. BRANCH CIRCUITS) 2.50ea ' NEW CONSTR. POWER APPARATUS & NON-RESID. (SINGLE OUTLET CIR. CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name St Ie Of' Y Ex. Occup(OUTLETS OR FIXTURES)50 @25q 104 FIXED APPLNS. OR EX. Occup. OUTLETS (RESID.) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No.3o2/ 3%Z Classification d_(/ Misc. Wiring 6.25 ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. Elhave placed on file with the County of Butte a certificate of 'workmen's Compensation Insurance. I certify that in the performance of the work for which this ermit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby TOTAL PERMIT FEE $2 duinonze a rese tauves or me county or tsutte to enter upon the above -me 'one ropertVriection purposes. X Date Sig ture of Permite.+e or Agent Receipt No.� 1--2 / White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF BLIC WORKS 71 BY Date 7 7 BLXding permit expires Date /— 7 LT/ —7rP PERMIT NO. 5829-76B PERMIT EXPIRES OWNER George Sleeter CONTR. Holmes Mobile Home Service, Bangor LOCATION (A.P. 34-61-25 108 Kristee Plane, lot 229,'KRlkl, Oroville Temp. Power Pole Called PG&E Temp. EleakServ. Cal l ed;P G& E Temp. Gas Serv. /Called PG&E FINALED (Dat Signature) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS ' BUILDING INSPECTION RE -CORD BUILDING BUILDI (Cont'd) PLUMBING Setback s Firewall Soil Piping Forms Para ets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor StemwaII Siding To out Slab Roof Sheathing �— 'i% Water Piping Piers Roofing — Sewer Garage Fdn. Vents Fixtures Footings StemwaI I Garage Vents Insulation Water Htr. Heaters Slab Carport Footings Prov. for physically handica e Conformance of ex. structure Appliances Gas Piping & Test Temp. Gas Brown Cooling Temp. Pole Slab Final Sanitation Patio FIREPLACE Final Footin s Footing ELE ICAL Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam FIR6SPR01h&RS Motors Framing — Test 1 Water Htr. Stucco Final Subpanels Mesh MECtIMICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Underground j Interior Lath Ventilation ° Permanent j Door Closer Final Final DATE REMARKS OR CORRECTIONS (NOTE: An entry must be made on this form each time you visit the job site.) C COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Uroville, California 95965 Telephone: 534-4541 APPLICATION AND PERMIT authorize r9presentatives of the County of Butte to enter upoH the above -men I ned roperty for in pection purposes. r Date Sign Lure of Permite or Agent Receipt No.7/ White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions'of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF nBLIC WORKS By - Date-/- Z Z-2 b /�- -? 7 B ding permit expires Date yz _ BUILDING Owner C4i OQ&C ��`c—€'��j� SQ. FT. OCC. BUILDING VALUATION 30 Mailing Address Telephone No. Fireplace Contractor �f�rr C� ��0/�/4 C �a/y�� ��j/GC Total Valuation /ZO c7 Mai I i ng Address p Q. �l 13)13)e' Permit Fee Plan Checking Fee &/or Penalty ,94A,-Oa2� p'_15� Telephone No.l'>�i� '79 -�7_ 51a Permit Fee $ 2-00 /Z cic Building Address PLUMBING No. @ FEE PERMIT FILING FEE $3.00 �1 Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 {�• /e• - (iT Each gas water heater or vent j 1.50 OA-srrA A. P. No. 3 — " Z- Zoning & Planning Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 Fees W.C. Sa )9. FireDept. FireZone Use Permit B((i[ding sewer 5.00 EQA Parking Parcel Plans Declaration Parcel Ma p 60' R/W Improvements p Lawn sprinkler system 2.00 Bldg. Plans Recd Parcel Approval Plans Approval Permit Fee $ $ NEW -0 ADDITION ❑ UTILITIES ❑ OTHER ❑ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Main service 100 AMP ORV OR LESS5.00 Main service EA, ADD -L. too AMP 2.50 Single Family ❑ Duplex ❑ Mobil Home Others ❑ Main service 1100EAMP OR LESS 25.00 Main service EA. ADD'L too AMP 1.00 NEW CONST. DWELLING OCCUP. & OR ADDNS. ACC. BLDGS. 20 sq ft NEW CONSTR. MULTI -OUTLET NON.RESID. ( BRANCH CIRCUITS) 2.50ea NEW C ON ST R. POWER APPARATUS & NON. RES ID. (SINGLE OUTLET CIR. CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of; /f/� Y cif'/ !� �� „ / � C/`�/1�� G Q l L /&i. Ex. Occup(OUTLETS OR FIXTURES) BA 25 Ex. Occup. FIXED APP LNS. OR P•(OUTLETS (RESID.) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No..22=1 3 % ,� / - ,�_ Classification Misc. Wiring 6.25 ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE J$3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby TOTAL PERMIT FEE $ C authorize r9presentatives of the County of Butte to enter upoH the above -men I ned roperty for in pection purposes. r Date Sign Lure of Permite or Agent Receipt No.7/ White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions'of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF nBLIC WORKS By - Date-/- Z Z-2 b /�- -? 7 B ding permit expires Date yz _ County. of Butteo PrfetNC'woa s � DEPARTMENT OF.PUBLIC WORKS jfornla95965� :a NOTICE TO. OWNER MITk., ,1LDI Post job card in a.safe, conspicuous place at front of lot. ' OCGr BUILDING VAl-1A710N Do not remove until the required inspections are made and - ex ; building is approved for -occupancy by this department., Plans must be available on job. 3 a. `atlon y. George Sleeter OWNER k'ingFee•&/orPe6alty' A. P. NO. 34-61-25 e ,� .i?LUMB'ING;' @ 'FEE - CONTRACTOR owner ILING`'FEE w$300 . 4906-75 P E inage or ve-0lping r+ 1:50 , 'r,F PERMIT NO i,:'► ,., rig t 4t� DATES + << 9 26 75 titer heater oYvent -� - systema. - 5,6utlets '-x,.50 " w , -� �`' K tonal outlet. X30 Approvals of -Foil owing Must Be Dated Before Proceeding -o ewer 5:00 �a « r a kler system ' r 2.00 BUILDING,_: PLUMBING ELECTRICAL . 1 Setback / 7� Rough Temp. Pole Forms Topout Rough11-14-7 LECTRIC,A'L ; No @ SEE Rein. Steel - Water Piping ./ -7J Underground 1lING;F,EE r $3:00 Piers Gas Piping Subpanels -• e Bond Beam Sewer - -7 Service Ce Incl _1PD1e�teT Framing Water Hir. J Final "meters,,eaC1L 7.00 ()2or`less3 �thoreYf�an12;, ": _r r,. i 1 Stucco Mesh/Lath Fixtures MECHANICAL ,ok-to�:or Stucco Coats 1- Water Supply Heating .� < �, s ter or Space.Heater + . 1:00 2- /3- Septic Tank Coolingres' '- 20 25. Windows Final Ducts +~ b 16 f twitches & fix outlet-, SidingFIREPLACE Ventilation anorF..A. Turn, Motor ,'.•.1,00 Roofing Footing Final , . ern gar tlisp or,D:W •-' 1 00`� Insulation Cert. Throat MH INSTALLATION. �,. - �` '.+. Final Final -� Final inner or heat pumps ' • . ', a"uFacll"iies,� '�,� 15 00• t „'� ` i �.� .� `c'-� , n9. x' aFgY CHICO - 695 Oleander Avenue - 343-4211, Ext. 70 OROVILLE - 7 County Center Drive - 534-4541 PARADISE - Skyway and Elliott Road - 877-3435 '- - ECHANICAL ,.,„» `.L o'�FEE � � ='�• Z tL11�G FEE $3.00 a r I' am,aware�titie.-provisloris oiiSect1oo.37.00 of the Calmfiornla;Labor": Code whichtre,'qu res .eve • em 16yer toVbe;Insuf4d agamstrltabllfty', .for"Workmen;s�C`ompensatlon: P F' I•have placed+ija'fl a wltfl.the County of, Butte axcertlficafe'oi Cooling , ; r r1 . �° Workmen's Compensatlon:(nsurances, y ! • .•d'certi that In the- perfor tinea -of the.'work fo wlrlch chis fy' - F r� - R V,erltrl atl on ` ®,permlY Is Issued 1'shal-1 not employ any person,rn any manner, x '.so as fo become subject }to •the Workmen's Compensatlo'n t-aws of }fools A -o0 t" ^s•California' ''• r, ° '' P.ermltl=ee $ ,. w s I certify that 1' have read this application and sdste.-that the.;abo%ie information is correct: <I ag�ee,I' comply,to alt�County:Or89nances * ,. m :and "State Laws`trelaing to' buiidirg'.;construction, .and'he�eby''. TOTAL PERMITFEE� autt driie"re resen_fatlV,es.of the'Coun •of, Butte to enter upon the A � 5 .A +s This pfermii `is hereby issued•iinder }fie applicable provfsfons o#- above r►Mention}ed.propert_yYor•Igspe�iion�puiposes� -: y " ,the'Bu_tte.CourityCode;and/or r'esofvtlo�to.;do work'tidlcat6d �' '' F /`'�,.,.� �T�'s(w .��•'� _ �� .abOVe fO,r„whlCf{,-eeS hgvebeerrpald n DI#ECTOR OE PUB.L IG WORKS Date'. 1 r -41, r , a . -Si1grialu re_of P6 rm_ i_iC.rc.. Rt i : J L v .mate A V t,., y • p t '•-y _ _" "h�k;� h +?�. yr ` �_ p�V f^-XelTow- Spector*»°GoldeRrot�ppli-canYs. }7j 1d9ng��1 rfnl expfes ate v P tom, 1 7 ,,h BUTTE COUNTY DEPARTMENT'OF PUBLIC WORKS 7 County Center Drive, Oroville, CA. PHONE: 534-4541 MOBILEHOME INSTALLATION SHEET 1. Owner's -name: George Sleeter 2. -Installer's name: Carneros Mobile Transport 3. Is the site currently under permit? Yes /X/ No (If yes, furnish permit number 4906-75 P,E ) OR Is the site an existing site? Yes / / No /X/ „(If yes,,;furnish two (2) plot plans.) 4..! Will the mobilehome be located at least 5 ft. away from septic tank and leach fields and .clear...of all setbacks and easements? Yes No (If no, clarify (This information not required if pipe length less than 6 ft, on natural gas or less than 50 ft. on LPG.) .L 5. What is the mobilehome electrical rating? ----------------------- 200 Amps 6. What is the mobilehome site service rating? --------------------- 200 Amps 7. What is the mobilehome site circuit -.breaker rating? ------------- 200 Amps ° 8. Is there any other electric load to be,.served'by..the mobilehome site service? -------------------------------------------'-------- Yes / / No /x / (If yes, identify the load and size: (Load) -0- (Amps) 9. What is the mobilehome site gas pipe size? ---------------------- -0- (in:) 10. What is the type of gas service? ----------------------------- Natural / / LPG./ / 11. What is the gas pipe length from meter or tank to the mobilehome? -0- (ft.) "- 12. What is the mobilehome gas demand? ------------------------------ -0- (BTU) (This information not required if pipe length less than 6 ft, on natural gas or less than 50 ft. on LPG.) .L MOBILEHOME- SUPPORT DATA Mobilehome Mfr. Mountain Valley. -Setup Model No 24x683Bdr."2bthyear. 76' Width' -•24 (ft.) Length 64NC (ft..). Expando. Size ft.ic ft: (Draw support details below) On all mobilehomes manufactured after October -7,.1973; furnish manufacturer's installation manual and structural setup sheets (if not on .file with the County of -Butte). Sin le - ►, Footings- (check. one) _ If, / 1. Wood -either I -- pressure treated or Center Center Support {. fdn: grade: Footing Sizes (in.) 24 x301 in.)Cin. 24x30 in.) (in.) /0�=__�_ --- l (�) 24 x30 J (in.)(in.) 2. Concrete pad. 3.. Other,: specify Supports (check one) AL1. -Concrete block 2: Concrete piers 3.• Steel piers 4. Other, specify Typical Support �12 x 30 Footing Size in. in. r --Max. Pier S - 6 Spacing g" 24 30 Y �ft. in. in.) �,.� 24 x30 � ®--• : - � ----- �-- - . b.� (in.) (in.) Max *If center piers are other than drawn above, draw in locations, spacing, and dimensions. k3UTfE COUNTY BUILDING DEPARTMENT APPROVED C ® 0 K ASSOCIATES ENGINEERING CONSULTANTS 2060 PARK AVENUE OROVILLE. CALIFORNIA 95965 `• PHONE (916) 533-6457. James Glander Department of Public Works 7 County Center Drive Oroville, California Re: 75258 November 3, 1975 Dear Jim: Compaction test results are enclosed for mobile home site preparation at Kelly Ridge Estates for:* Whiteside KRE Unit 3 Lot 184 >Mcool KRE Unit 3 Lot 262 S�leeter KRE Unit 1 Lot 229 `Anderson RE Unit C Lot 18 Oro Ridge Properties KRE Unit C Lot B Representative tests indicate that the.90% relative compaction requirement has been satisfied. A location map is attached. Very truly yours,. CO ASSOCIATES Alan G. Brown Civil Engineer AGB/cap Enclosures D0.�1'.t. COOK O, E. i_!�Y1) i:1. CUO r, cam,. 0. .JOE E. C!'r.:: is t,. E. - ProjEct Sleeker Lot 229 C 7 .-a._.SSQCIATC-Snit 1 75258 Job Number Ef.:SiNEEREF:G CONSULTANTS Nuclear Ire -Place Alan Brown 2060 PARK AVENUE Tanen By OROVILLE , CALIFORNIA 95965 [VioiSture Density. Test ®ate October 1975 ( 916 533 —6457 TEST NUVIEER 1 2 3 4 5 6 7 8 9 10 TIF.!E 10-3 10-14 10-17 10-27 lst lif 2nd lift rd lift 4th lif TEST Middle SE Cor E side NE Cor _ LOCATION side of of fill of of fill fill fill t,!ODE G DEPTH 8" DT 8" DT 8!' DT 8" DT f,!OUNTE C COUNT 960 1126 1012 1073 d --.-t. MOISTURE COUNT .RATIO .681 .791 .711 ..759 - PriOISTURE PCF 16.75 20.25 17.75 19.0 DENSITY COUNT 197 218 216 219 DENSITY COUNT RATIO .716 .792 .785 .793 X7ET DENSITY PCF 144.5 140..0 140.5 140.0 DRY' DENSITY PCF 127.75 119.75 122,75 121.0 % f 1,01STURE 13 17 14 16 OPTIMUM DENSITY PCF 133 133 133 133 % OPTUMIUM —� &OISTURE 10 10 10 10 % RELATIVE CO,'PACTION 96 90 92 90 STANDARD COUNT C01,1f.SENT: t: OISTURE DENSITY ---- 1409 _ 275 - 10-3 1422 275 10-14 1411 275 10-17 1412 276 10-27 IL . . .................. L ------------ 6x- e e .a a �° o° LOT 229 UNIT 1 ace' LJ 6 _. - 4) 57 mif w.0 Ue etq-uit� 1 490 ��. a in ation of the mob le S• . OiB- rhe Setbbi shall thee ' side roe ' p r� line and 50 t he centerline of the road, pefml'ttin' g-- p 0' 9 maximum of a ft. eave ovprhar�a \� ' N All t�Yilii necti located wit i 4 ft °ns �he�,L�; third sectio on the left (' o ° t �rbbile home��_ 4 home. side of the mobile "o o. a _,4!:::;NIG%V 7_. I'his set of planta MUST 'be cepa on the job at all times and it is unlawful to S''EVVE/Z make any changes or alterations on same without wrHfan permisson from the Department of Pubtir Works, County of Butte. ' 7V oTF- -:.A,�,�z_o_x,__.��L�C11�b5EP�RT�MENT NOTE:—Alr Mc;terir.ls & VVor4mrenship Shall Be in APPROVED Accordance with Recognized Good Practices and of a quality prescribed for. the Specified use in the Uniform Building, Plumbing & Machanical Codes and D 9-�.77s /TrG the National Electrical Code.''6 4�" �'' - -- 1