Loading...
HomeMy WebLinkAbout069-210-005RICHE D G, RAHN 17 K0 Ll 69-21-05 e Dr, lot 3, KR#3, Oroville Contr: Spar ks Const Permit 774-85ni.(util, MH) ELEC —� GAS PPORT STRUCTURE REQ COMPACTION TEST RE Albachte,,- 11 D vis05Mys Contr:; � •� Permit#104.3y83MMHHI Issu.ed�/—/�5� Wool-- — 69-21-05 Contr; Sparks Construction /—/ C.rt" Permit#1240-85B(new decks/MH)-7//(0A5' 69-21-05._. Contr: Sparks Const final '7�1Ia/ Permit#1746-85B,E(new private det garage) 69-21-5 F1114L�� Contr: Sierra Mobile Ser Qf -2 Permit#2087-85B(awnings/MH) O� a 1 069-210-005 #98-2266 RAHN, RICHARD 17 KOKANEE, OROVILLE SIERRA MOB ILEcjNAG iofziq$ MH PERM FND EXISTING SITE i�- -� � �� ,,RECORDING REQUESTED BY: AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 COPY of Document Recorded 22 -Oct -1998 1998-0045857 Has not been compared with original Butte COUNTY RECORDER SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME) OR COMMERCIAL COACH, INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. RICHARD G. & DOROTHY L. RAHN BUTTE COUNTY BUILDING DIVISION REAL PROPERTY OWNER/LESSOR LOCAL AGENCY ISSUING PERMR and CERTIFICATE OF OCCUPANCY 17 KOKANNE DRIVE 7 COUNTY CENTER DRIVE MAILING ADDRESS MAILING ADDRESS OROVILLE, BUTTE, CA 95966 OROVILLE, BUTTE, CA 95965 CITY COUNTY STATE ZIP CRY COUNTY STATE ZIP SAME 9 2266 (530)538-7541 INSTALLATION MAILING ADDRESS, IF DIFFERENT E NO.TELEPHONE NUMBER 10/21/98 CRY COUNTY STATE ZIP siGNAW OF LOCAL GENCY OFFICIAL DATE SAME NONE UNIT OWNER ff also property owner, write 'SAME) DEALER NAME ifnot a deWer sale, write 'NONE7 MAILING ADDRESS DEALER LICENSE NO. em COSNf'r STATS ffi UNIT DESCRIPTION FAR WEST HOMES 1985 FAR WEST HOMES 09945 MANUFACTURER'S NAME DATE OF MANUFACTURE MODEL NAMEMUMBER 3609A/B 60'X 24' 303851/2 SERIAL NUMBER(S) LENGTH X WIDTH INSIGNLkILABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPnON ASSESSOR'S PARCEL NUMBER A.P. #069-210-005 SEE ATTACHED HCD FORM 433(A) REV. 8/91 WHITE - County Recorder CANARY - HCD PINK - Applicant GOLDENROD. Building Dept LEGAL DESCRIPTION A.P. #069-210-005 All that certain real property situate in the County of Butte, State of California, described as follows: LOT 3, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "KELLY RIDGE ESTATES UNIT NO. 3"., WHICH MAP WAS FILED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, JULY 26, 1974 IN BOOK 43 OF MAPS, AT PAGES 44, 45, 46, 47 AND 48. THIS CONVEYANCE IS MADE SUBJECT TO ALL OF THE COVENANTS, CONDITIONS, RESTRICTION, TERM AND PROVISIONS CONTAINED IN THAT CERTAIN AMENDED DECLARARION OF RESTRICTIONS (KELLY RIDGE ESTATES) FILED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON MAY 3, 1972 IN BOOK 1755 OF OFFICIAL RECORDS, AT PAGE 65, AND SUBJECT TO ALL OTHER EASEMENTS, RIGHTS OF WAY AND RESTRICTIONS OF RECORD. :.:::.::::::.::::::.::::,.:,.................................................................................. BUILDING PERMIT NUMBER: 98-2266 Address or location of unit: 17 KOKANEE DRIVE, OROVILLE, CA 95966 Legal Description of Real Property: A.P. #069-210-005 SEE ATTACHED (x) Mobilehome/Manufactured Home O Commercial Coach Has been affixed to the real property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: RICHARD G. RAHN OR DOROTHY L. TENCOM Owner's address: 17 KOKANEE DRIVE, OROVILLE, CA 95966 INSIGNIA OR HUD NUMBER: 303851/2 SERIAL NUMBER OR V.LN.: 3609A/B MANUFACTURER'S NAME: FAR WEST HS YEAR: 1985 OFFICIAL APPROVING INSTALLATION: DATE: 10/21/98 PHONE: (530) 538-7541 H.C.D. 513C 10/'yj2/1998 11:42 9165894919 LAKE OROVILLE REALTY PAGE 02 STATE OF CALIFORNIA -DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT Ed .... DECAL No. +»+ MANUFACIURER NAME!10 1RAUE NAME moot nom not OF5 SP EI FAR NEST HOMES/09"S FAR WEST 2060RL38R 04/19/85 04/19/85 05/01/85 1 3609A 2 36098 13 a' 5 6 A RAHN RICHARD G/ o DOROTHY L TENCOM OR o R 17 KOKANEE e s a. OROVILLE t R RAHN RICHARO G/ e DOROTHY L TENCOH OR V M I A 17 KOKANEE sI T L OROVILLE R C 0 o s 17 KOKANEE w N T t u OROVILLE Ra n 0 A L 0 w N C z N 303651 303852 018300 1 000720 I 000144 01%00 000720 000144 m TOTAL FEES PAID: $40.00 SFO J V P N I R O S R T L I t w s N t 0 C L O 0 N � D � R IMPORTANT 01-iS7-Ort ..�.......��.... ...... ... •�....� •. ... .. r••. •.. . .�.... wcnnnncw ...tu tur t.rbaM9'Y ruy GGT. -US 98(&IO,N U9: i1 FIDELITY TITLE ' . v age -410411O." aeouse.ee we .�. r... «•.r«. d... .0 r+ 1 ♦•w ",, 6.14 at R1II Ord C, Naha ••••••• 121n0 P#v r,rt A.,,.., ill • • • 1•101 In, CA 17b1V TEL:916 536 1526 Til It t> ter Nn . _. . f .cm. P. to 43730 a•Ate .Isoes Tw•a 11,11164 too A•Coltotill's Yat meeemmeeee­ f " rt.o. Vdd" •.ewer.w baa l....... !6150 ...... ..� ` 1Vr t'.�e.l.a .. tell •91.r of d^•r+•t, c..wrN. 0• O..r►. '1 U.wsaw eve tall waive law, jorm and MMMMYeea A44re.e Aboee v rr-9.e,ee u.ww at usi9af Oats. plrTlt COk-ff T ITLZ C"AMT r CcrporatI .. _joint Tramp hitt gra-t►� I. r1.IMr M to, I (tk t'AIA'l Oil CI IVI II. SOV wON CALITDRAtA f►1114M141 Ctl1 PMAT1ON t:RANT%lot ■ICItAIID C. RAIIM and lxftCTM L. MM, husband sod wife a• ItIIWT YrNA%-M dl lhat oral p etwila teuale m the Dnincerpr0ted area co,"ry .t w c to . Late d Calitoeay de•en6sd u follorc : Lot 1, sa show" on that eort•ln rp entitled, "KLLLY Rlxe [STATES UNIT MO. 30, ,which err was filed in the office of the Recorder of the County of swtt06 [tate of California, Jul, :a, 1174 in Boot, 47 of papa, at Nleo• K, t,S, 464 47 and As, This Conveyance 1• wade aubjret to all of fthe cev/nant0, rteAdltlotld. IdattictltMB6 ere• end proviei•nO conlarhed in that ceftain a•.•nded Declaratios of [e•trltilotas (KELLY Rl]CC ESTAtT.$) filed in (hr oftica of the Recorder of Cha County Of suttBt State or Celifurnis, 011 May ). 1912 in Cunt I01I Of Official Records, at pogo 63, and subject to all othrr rarrlw•nte, r►shtO of ,way and reatrictlons of r0coed. IN WITNUS M HERCOF, aa.d eerYrtra11ra1 hr rucuted Thee f e ruff toy its Otlic'en ll rnrwoo duly •aUmttordr Ute 15th day of Jun• IV 76. S0UTHIM CALLiattlttA TtRANCIAL C0Rp MAT1t1M •TATS DY: BVTTL cgywry TITLL C171VAM 01 CALIfORSU ) _ C0tVNT7 't/ RVTTE ) Ill_ ^ e-04 - h.ne►r before me. the M R. On unirr.aattard vetwn• y app.cced at•rr•a.f ValIntana end�cn 1;_ Eald,wln hn•*g1 to K t0 be the vte.- tree' rr� and the r_ lecrelary of the torr^rotten Shot •sccutad the wlthln in.truernt and 0109 to be the porsoss e/1n e.rcutrd It an bahelf of ouch torrersit"n and •cbnowledled to .0 that Ouch CO►peretlolt executed the $a9w •s Ott^lnry In fact of to,wtnorn Calltu nla "Tint l Ot Cnrpl.rOt ltrl and scbnotiledtlod to �• that they Oubscribrdthe new of prof"" n Califnrnis rinantial Corporation 411cretu as principal and Rvtto County Tll:e ClawpanT'• nsar as attorney is fact. 2T[ AT60MT LM f,Wq eon woTaev Bleat on luau• a IN ,,,ff�77'��� e••rla. N.• 1 be", .1 talo/0a•.a •a,M 11 11 .1r1. t le 9.106 tOYe1e Me te'O"'em, Itwla r, m. 1, 1"M i Mo of ooCvwfl rvo s9 O1noCT49 ataOc•l P. 003 X069-210-005 #98-2266 RESIDENTIAL RAHN, RICHARD 17 KOKANEE, OROVILLE SIERRA MOBILE MH PERM FND EXISTING SITE PERMIT NO. • ' I\ U-/ - PERMIT EXPIRES t OWNER CONTR. ASSESSOR PARCEL LOCATION THE HCD FORM 4339 FOR THIS MH CANNOT BE RECORDED UNTIL ONE OF THE FOLLOWING HAVE BEEN TURNED IN TO THE BLDG DIV: r (1) LICENSE PLATE(S) or DECAL(THE INSPECTOR MUST RETRIEVE) (2) STATEMENT OF FACTS(ONLY ON NEW MH'S) INSPECTOR TO VERIFY SERIAL & LABEL #'S CHECKED SRA BY FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY Temp. Power Pole — Called PG&E— Temp. Elec. Service _ Called PG&E — Temp. Gas Service _ Called PG&E — JOB FINALED (Date) 1Z1 19d Signature V=OK O = Not OK Nott ReadApply MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements - Setbacks - Easements 2. Soils; Special MH Support Sketch 3. Sewer, Location -Test -Fall -C/O -Concrete 4. Water, Location -Test -Easement Needed (Sketch) S. Electricity; Location-Clearances-Gmd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap; / tUft. / /Nat. or/ iL°ft./ /LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Cana B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector fieVFat;r7MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Ce f Occupancy It --,Permanent Foundation Only: License Decal Date 7b7Z,( #1 Card B-1 Date Card B-1 r Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; SoilsSize-Dep"pacng-Connectors-Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rttrs.-Connectors Shthg.-Rfg.-Bracing S. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sils-AnchorsStuds-Rttrs-Trusses 9. Siding; Nailing-VeneerStucco-Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pod Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5 -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/9 Circulating Equip. -Pod Lghtq. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ✓ = OK 0 = Not OK - = Not Applicable * = Not Ready RESIDENTIAL (Single & Duplex) Date UNDERFLOOR (Plans) OK except #'s 1. ZoningSetbacks-Easments-Flood-Slope 47. 2. Ftg., Main; Soils-Elec. Gmd. / /° Ftg. Depth 3. Ftg. Garage; Soils-Steel-Elec. Gmd/ N Ftg. Depth 49. 4. Ftg. Porches & Decks; Soils -Steel-/ N Ftg. Depth 50. 5. Stemwalls, Main; Steel-Blockouts-Wrapped 51. 6. Stemwalls, Garage; Steel-BlockoutsaNrapped 52. 6a. Hold Downs and Special Anchors 53. 7. Slab, Steel -Wrapped 54. 8. Piers -Fireplace Ftg.-Steel 55. 9. D.W.V.; Fall -Fitting -Test -2 Way C/0 -Sewer Test 10. UF. Gas Pipe; Size Anchors - Yard Gas Piping; Size Test Siding -Nailing Veneer 11. Water Pipe; Test -Anchors -Regulator -Service Test Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 12. Electric Underground 58. 13. Plenums & Ducts; Clearance -Material -Support -Ins. 59. 14. Girders -Sills -Anchor Bolts -Joists Vents-Crippies 60. Brace Interior / Exterior Wall Panels 15. Access & Ventilation 61. 16. Insulation 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 68. Elec. Trim & Subpanel, Breaker Sizes & Labels Date 69. Card B-1 Date Card B-1 Date 70. Card B-1 Date Card B-1 Date 71. ELECTRICAL (Permit) OK except #'s 23. Fixture & Transformer Clearance -Ins. Protection 24. Elec. Receptacles Spacing -Lights & Switches at Doors 25. Size B es & No. of Conductors Stapled 26. Romex I stalled Close to Edge of Studs & C.J. 27. Equip. Ground made up w/Mech Fastners-Bond Gas & Water 28. 2 Appliance Circuts in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or Al 30. Range Circ. / / ga Cu or AI -Oven Circ. / / ga Cu or AI Insulated Neutral 0 Yes 0 No 31. Service -Riser Conductors & Ground -Main Disconect 32. Equip. Clearances Panels-Motors-Mech. Epuip. 33. Clothes Closet Light -Shower Light -Spa Light 34. Smoke Detector 84. A.C. Unit Disconnect, Electrical -Plumbing Date 85. Card B-1 Date Card B-1 Date 86. Water Well, Disconnect, Electrical, Plumbing Card B-1 Date Card B-1 Date Exterior Elec. Trim, G.F.I. Receptacle -Underground MECHANICAL (Permit) OK except #s 88. 35. A.C. Ducts Insulation & Support 89. 36. Vent Fan, Exhaust above insulation 90. 37. Condensate Drain & Overflow, Size & Grade 91. 38. Fumance-Vent Access -Comb. Air -Return Air Vent 115 outlet 92. 39. Attic Access & Platform if Furnace in Attic 93. Energy Compliance Certificate -Other Certificates Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 FRAMING (Plans) OK except #'s 40. Sits Proper Materials & Anchors 41. Walls Studs -Nailing Spacing & Braces -Plates -Sound 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing Date FRAMING (Continued) 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rf r. Ties-Purlin-roff Brac.-Truss-Shting.-Ring. 48. Fireplace Ties or Type A Flue -Fireplace Throat clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One 3 -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior / Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace; Vents -Clearance -Comb, Air-Conector- In Garage; Above Floor -Ducts -Meth. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground. -Air Gap -Cooking Clearance 73. Elec. Outlets & Recepticales at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. In Garage; Above Floor -Meth. Protection 77. Plb., Elec. & Mach. Equip. Listed for Location 78. Elec. Receptacles in Garage (G.F.I.)-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor 0 Yes 82. Following Instld./Drive 0 Yes 0 No/Walks 0 Yes 0 No/Planters 0 Yes 0 No W. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throught House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 E I N (Rev. 12/96) APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER 069-210-005 - ZONING BUILDING PERMIT OV OWNER RAHN, RICHARD TELEPHONE SO. FT. OCC. BUILDING VALUATION 1440 77 760.00 .OWNERS MAILING ADDRESS 17 P CONTRACTOR'S NAME SIERRA MOBIT. TELEPHONE 87 7-8- 575 CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ 77 760.00 ARCHITECT OR ENGINEER LICENSE No. Filin Fee $ 20.00 Permit Fee $ 270.25 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 23.00 BUILDING ADDRESS 17 T A NEE Energy Plan Checking Fee $ $ OROVILLE PERMIT FEE $ 313-25 LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE gg SF El Duplex 13Mobilehome fl Other SPECIFY Each Trap 7.00 Solar or heat um water heater 23.00 Water piping 15.00 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ PERM FOUNDATION ON EXISTING Describe Work: SITE Gas piping system 1 - 5 outlets 15.00 15. UU Building sewer 14Fee20-00 Mobile Home S G W @2 PERMIT FEE $ ELECTRICAL PERMIT Flin Main Service 200A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is inUll force and effect.r i qLicense Class Lic. No. ? O Z $L OWNER -BUILDER DECLARATION hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP. OR ADDNS. ( & ACC. BLDS. SD 3.5¢FT. �"E'N"p°,p MULTI.OUTLET @7.50 POWER APPARATUS 8 SINGLE OUTLET CIR. Ex. Occup. OUTLET OR FOCTURES 20 Q 1.00 EAL @ .50 FIXLUI Ex. Occup. DimtDs(RRES,6D Ew 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the rformance of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permitis issued. My workers' compensation insurance carrier and policy number are: Carrier <;:� `� MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FET= $ Policy Number c( G - !7 (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. �� An 21 X I�(..�- � Date � � I � Signature of Applicant - ❑ Owner ontractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE $ 363.25 HAZ. D FEES IMP FLooD CDF _ PAR SEL V Pp HD ISsuE This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have By PERMIT EXPIRES ON the applicable provisions Resolutions to do work been paid. Da lz Dete Receipt No. 250689$63.00// c WHITE -D. -B. D. CANARY -ASSESSOR PINK-INSPEr.TOFF XOLDENROD-APPLICANT COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 PERMIT NO. (Rev.12/96) c nV APPLICATION AND PERMIT - TPG A.spsoaPARIxiNUMeetl a 00 m►.ta -,� Z� ,� O BUILDING PERMIT TaEPIq"° SO. OCC. BUILDING VALUATIO OWNFA7 MAUNO AD011lSe OOMMCIOR-! NIIM! , / �M& � tEMMS MAJUNG AWFMS - - _ T -Ire lace Total Valuation is ARCNITECTORENmNEER UCEWENQ Slina Fee $ 20.00 ARCWMCr OR ENMMM S MALM ADDAM Permit Fee $ Plan Checkln Fee $ -- LDMMS all ADO Energy Plan Checking Fee $ i PERMIT FEE _ WTNM sueonbcNSNAre PAac� MAP PLUMBING PERMIT Filing Fee 12o.00 USEOFSTRUCTURE Each Trap 7.00 Solar or heat pump water heater 23.00 SF 0 Duplex O Mobilehome O Other Water piping 15.00 Each as water heater or vent 15.00 ` TYPE OF WORK Gas piping system 1 - 5 outlete 15.00 New O Addidon 0 Remodel O lldGdes O Installation O Other 0 Building sower 15.00 n Describe Work: /_ �n �d �/ --(� 9 ev lz <05 j Mobile Home I S I G I W ®20.00 PER FEE _ ELECTRICAL PERMIT -FIlIngFeel 20.00 410WMain Service zooA o0R L 23.00 Main Service 200A TO 1000x► 46.00 NEW CONST. OwB1110 OOCUR OR ADDNs. a Acc. a.Da 80. 3�'.50M ` NONAESID. pwumew entr2j�w I 97.50 Ex. OCCu . OUTLET OR R MED eAL -9 Ex. Occup. o,° Mj M 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE _ MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 1 6.50 PERMIT FEE i Mobile Home Installation Fee $ Energy Inspection Fee $ EOCCONST. Tr NAZfPWE- TOTALFEES E® IMP I 8000 I OOf I PARCEL PD 6S UE This permit is hereby Issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date Receipt No. roD PERMIT EXPIRES ON WHITE-O.O.S.-B.O. CANARY -ASSESSOR PINK-INSPFCTOR RF3t nFNRnn.APPI ICAu1T . . COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET OWNER: ALt 4 ASSESSOR PARCEL ER: Proposed Building Use: Building Inspector: Date: At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: Date Received By ❑ 1. All items have been submitted ----------------------------------------------------------------------------- 02. Plot plans, 3/4 sets, signed by the preparer of plans. ---------------------------------------------------- ❑3. Complete plans, 3/4 sets, signed by the preparer of plans. --------------------------------------------- 04. Engineered'plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! --------- ❑ 6. Energy Design Compliance and supporting documentation. ------------------------------------------- 117. ------------------------------------------ ❑7. Statement of Intent for Non -Heated and A/C Buildings. ------------------------------------------------ ❑ 8. Hazardous Material Form.--------------------------------------------------------------------------------- ❑9. actured Home data and in-sstallation instructions including Tie Down Specifications .------------------ ff-�_-�ofs:100,15--^---------------------------------------------------------------------------------- Z C� y ❑ 11. Impact fees as shown on the attached schedule. ----------------------------------------------------------------- ❑ 12. California Department of Forestry plan approval/fees.--------------------------------------------------------- ❑ 13. Flood elevation certificate. ❑ 14. Sanitation and plot plan approval Health Department. 1115. City of Chico plumbing permit. --------------------------------------- ❑ 16. Plot plan and business license approval from the City of Biggs. --- ❑ 17. Planning approval for (A) Use: (B) Parking: _ ❑ 18. Contact Land Development about ❑ Improvements, ❑ Drainage, ❑ Legal Parcel. ❑ 1.9. Encroachment Permit for driveway (construction approval prior to occupancy). --- 020. Pre -inspection for 021. Contractor's license information. (Nw 022. Workers' Compensation carrier and p 023. Owner -Builder Verification (Given to required. Request to Building Inspector on Name Style, Classification). ---------------------- number - ---------------------number.----------------------------------------------- ❑, Mailed to owner ❑). 024. Letter of signature authorization. ------ A----------------------------------------------------------------------- �1 025. Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- ❑ 26. Letter of intent on building use. ----------°- ------------------------------------------------------------------------ R ❑27. Manufactured Home utility clearance. (Date) 1128. g vi at' and/or expired permits. �---------------------' ----- `l� o -------------------------- ❑29. Deed, ❑ M.H. Title, eck to $--------------�d" 1130. Other: ------ Wh, ou issue the ermit rojss ollows 11 Mail to owner, ❑n�z, ttractor. t l'J Telephone 8 7 -'� ! and hold for pickup at office. ❑Deliver with inspector. Applicant: ree Date: ` I Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, 4 Air Pollution Date: By: Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Other: ate: By: 1. Index permit application for the above items numbered: ❑ Plan Check List 2. Additional items required: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Buildlhg.Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Plans reviewed by: Date: Plans approved by: Date: /d ' /Z- Sets LSets of plans on hold in ❑ Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division. 1 PERMIT NO. 1746-85B.E PERMIT EXPIRES �� v OWNER R_ RAHN CONTR.. Sparks Const ASSESSOR PARCEL 69-21-05 LOCATION 17 Kokanee,' Oroville 8 a • y1jh i 4; h' S •t I? y ,1 F AFS Temp. Power Pole Called PG&E Temp. Elec. $ervicp i Called P( g Temp. Gas Sei I Called PG JOB FINALEI I' Signature OK Not OK = Not Applicable MOBILEHOMES MISCELLANEOUS Not Ready Date MOBILEHOME UTILITIES (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except q's 1. Zoning Requirements -Setbacks -.Easements 2. Soils; Special MH Support -Sketch 2. Footings; Size -Depth -Spacing -Connectors 3. Sewer; Location -Test -Fall -C/0 -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 4. Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; Location -Test -Wrap:/ /"L"ft./ /"Nat. or% /"L"ft./ /"LPG 6. Carports; Windows -Doors 7. Utility Clearance 7. Elec. Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date MOBILEHOME INSTALLATION (Plans) OK except k's 1. Zoning Requirements -Setbacks -Easements Card -BI Date Date Card -BI Date POOLS (Plans) OK except N's 1. Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH Test -Demand -Valve -Connector 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining 4. Electricity; MH Test -Crossovers -Breakers -Clearances 4, Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test -Fall -Flex Connector 5. Elec.; Pool Lighting; 15 volts-GFI 6. Water; MH Test -Regulator -Connector 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/O to Grade -HD Approval 7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Gas and Electricity Tagged 8. Elec.; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg. Boxes -Enc losures- Pane lboards-Ins. to Main in Conduit 9. Health Department Approval 9. Exits; Insp.-Sketch 10. Cert. of Occupancy 10. Plumb; Cir. Test -Water Supply Test Card B-1 Date Card -BI Date Card -BI Date Card -BI Date Card B-1 Date Card -BI Date Card -BI Date Card -BI Date = OK = Not OK f = Not Applicable = Not Ready RESIDENTIAL (Single and Duplex) Date UNDERFLOOR Plans OK except #'s Date FR G (Continued) 1. Zoning requirements -Setbacks -Easements teAroperty Line Firewall & Openings 2. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth 491 Ext. Doors -One 3' -Check Garage -3rd story, 2 exits 3. Ftg., Garage; Soils -Steel- / /" Ftg. Depth hs, Width -Headroom -Rise -Run -Landing -Fire Protection 4. Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth lywood on Roof Overhang -Attic Vents -Rafter Outriggers 5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab 5L11 Wing -Nailing -Veneer 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab 53 St co Mesh -Drip Screed-Fdn. Vents-Underflr. Access 7. Piers -Fireplace Ftg.-Steel 54 zing Area -Glass Protection -Skylights -Plastic 8. D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test 9. Gas Pipe; Size -Anchors 10.Water Pipe; Test -Anchors -Regulator -Service Test 55*.' Shear Walls; Nailing -Bolts 11. Electric; Underground 12. Plenums & Ducts; Clearance -Material -Support -Ins. 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -B Date Card -BI Date Card -BI' Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date FINAL (Plans) OK except N's 56. Ext. Steps -Door & Sidelight Protection -Landings Card -BI Date Date Card -BI Date PLUMBING (Permit) OK except q's 14. Water Ht.; Vent -Access -Combustion Air 57. 58. Smoke Detector Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 15. 16. Water Pipe; Test & Anchors -Nail Protection D.W.V.; Test-Fttngs & Anchors -Nail Protection 59. Bedroom Exiting 17. Shower Pan; Test, First Floor -Tub Access 60. G.F.I. & Bath Fixtures & Tub Access 18. Test Tub & Shower, 2nd Floor -Tub Access 61. Elec. Trim & Subpanel; Breaker Sizes -Labels 19. Gas Pipe; Size -& Anchors 62. 63. Stairs & Rails Fireplace or Stove; Clearances -Hearth 64. Elec. Outlets at Wood Panel; Int. & Ext. Card -BI Date Card -BI Date 65. Kit. Fixt. &Appliance; Grnd.-Air Gap -Cooking Clearance Card -BI Date Card -BI Date 66. Elec. Outlets & Receptacles at Kit. Counter Date ELECTRICAL Permit OK except q's 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper 20. Fixture & Transformer Clearance -Ins. Protection 69. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 21. Elec. Receptacles Spacing -Lights &Switches at Doors 22. Size Boxes & No. of Conductors -Stapled 70. Plb., Elec. & Mech. Equip. Listed for Location 23. Romex Installed Close to Edge of Studs & C.J. 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 24. Equip. Ground made up w/Mech. Fasteners -Bond Gas & Water 72. Insulation -Foam -Looked in Attic ❑Yes73. 25. 2 Appliance Circuits in Kitchen &Conductor Size Guard Rails & Deck Construction -Post Caps 26. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 74. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 27. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or At, Insulated Neutral ❑Yes ❑No 75. Following instld.: Drive ❑ Yes E) No; Walks E) Yes ❑ No; Planters C) Yes El No 28. Service -Riser Conductors & Ground -Main Disconnect 76. Stucco; Brown -Finish 29. Equip. Clearances; Panels-Motors-Mech. Equip. 77, A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 30. Clothes Closet Light -Shower Light 78. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 79. Water Well; Disconnect, Electrical, Plumbing 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground Card B-1 Date Card -BI Date 81. 82. Ventilation throughout House Glass Protection Card B -I Date Card -BI Date Date MECHANICAL (Permit) OK except N's 31. A.C. Ducts; Insulation & Support 83. Corrections from Previous Inspections 84. Gas Test -Meters Tagged; Gas -Electric 85. 86, Water & Sewer Connected -C/O to Grade -HD Approval Energy Compliance Certificate -Other Certificates 32. 33. Vent Fan; Exhaust above Insulation Condensate Drain & Overflow; Size & Grade 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet 35. Attic Access & Platform if Furnace in Attic Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Comments at Final: Date FR NG Plans) OK except q's st.ills; Proper Material &Anchors Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound 88 -'Bearing Walls over Girders & Floor Nailing 397- 5raft Stop in Walls (rat proof) ire Stops; Furred Ceilings -Stairs -Chases -Tub Bader & Beam -Size & Bearing 4 F gers-Post Caps -Anchors -Connectors 42r' Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfn_g._ _ -44. 94e,place Ties or Type A Flue -Fireplace Throat 145iiTllc Access; Size & Romex Protection -Draft Slop -Ins. Baffles 46"8t1rm-Windows or Exiting Doors -Sill Hgt. & Dimensions 47 raraoe Fire Protection Framing (NOTE: An entry must be made each time you visit jobsite) J COUNTY OF BUTTE - DEPARY�IENT• OF PUBLIC WORKS PERMIT N . 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 /�( �/ — APPLICATION ANDPERMIT ASSESSO PARC L UMBER �— 0 ZONING '. ;•'.'`: i ' BUILDING PERMIT Ow TELEPHONE r SQ. FT. OCC. BUILDING VALUA ION OWNER'S MAILING A DRES r GH PIONE. CONT A TO •S NA E TELE 7 . CONTRAc OR'S MAILING ADDRESS t � b a M Fireplace CONSTRUCTION LENDER - UNK_ t�QWN, " "t• Total Valuation Is FijingFee $ 10,00 LENDER'S MAILING ADDRESS ,� Permit Fee $ ZXD ARCHITECT OR ENGINEER LICENSE NO.4 r, i Plan Checking Fee $ 91, aS- Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ r ' BUILDING ADDRESS PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar Water Heater 20.00 7 Water piping 5.00 LOT NO. SUBDIVISION NAMEPARCEL MAP Each Qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTUR C SF [:1Duplex ❑ Mobi lehome ❑ Other Del v, �Ji ' SPECIFY Building sewer 5.00 Mobile Home S G W 10.00 e TYPE OF WORK New B' Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other ❑ Describe work: — Permit Fee $ Contractor - ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. OWELLI O & OR ADDNS. ( ACC, BL 1 2/20sgft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): RL I am licensed under provisions of Chapt. 9, Div. 3 of the �`•''Business and Professions Code and my license is in full force and effect. License No. yS'5 8 J / Classification '3 El 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW cONSTRU TI.OUT LET NON.RESID BRANCH CIRCUITS2.50 ea NEW CONSTR.POWER APPARATUS & NON-RESID. (SINGLE OUTLET CIR. Ex. Occup(OUTLETS OR FIXTURES e0 50 FIXED APPLNS, OR Ex. Occup. OUTLETS (RESID.) EA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Q Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ® I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subjept to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence f the granting of this permit. %� Date r-�% — Signature of Applicant — wner ❑ Contractor 1K Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over in height. Mobile Home installation Fee $ TOTAL PERMIT FEE $ 3, —S' OCCUP. GROUP I TYPE OF CONST. PARCEL I PD HD ISSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECT OF PUBLIC By PER64 EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date oo3��stories Receipt No. `7 d /_ WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT LOT_3 UNIV,,3 1.7 NOTE;—All Ma•'re, ials & V`Jorkmc;rts'.',�� a fie m Accordance with Recognized Good Practi-es and of a quality prescribed for the Specified use i . e Uniform Building; Plumbing & Mechanical Codes and - This set of plans and specifirrytions MUST be the National Electrical Code. ' it n the iob at all times and it is unlawful to make afi �+aes or alterations on some without Asetback of 5 ft. from the Written permission rdrn e�partment of Public W�` Butte - property lines and a setback ��.�ounty of Buttes of 50ft. from t4a r� Xb/G #-&- L = 34,17' centerline shall be clear of GGA G structures or equipment except for a 2 ft. eave overhang. 'U a ,y \ � 0 0 O \ ri l ri BUTTE COUNTY BUILDING DEPARTMENT --� APPROVED w . ?Tovide 14" x 1 @ 6' o.q. ma) 12" of joInts' . FoulVDATION T /0 . A Ncwog SOL T.S To 8E I -PLACED, wmmiv // OF ALL -BREAKS E A..MA)( -,,,SP,4CiAfc7 oF-,.(,, '0c. 3" anc* bolt' FooremG 7-?PIC:AL E nd within I e( 'YZJCIOANCHOR -SOLT.&- RE BAR NITY BUTTE COU ART N\ENT BUILDING DEP ED pppO A eA P8 x.2 -a' -4, x HEADER Q Pic/ e-, Ll oc- 4x /'V .00OR HEADER m BUTTE COUNTY BUILDING. DEPARTMENT APP -ROVE n_ 5A, Icy PERMIT NO 2087-85B PERMIT EXPIRES - RICHARD /RAHN OWNER CONTR.. Sierra Mobile Ser 69-21-5 ASSESSOR PARCEL LOCATION 17 Kokanee bt 3, Oroville Temp. Power Pole Called PG&E Temp. Elec. Service Called PG&E Temp. Gas Si Called JOB FINALE Signature J = OK O r Not OI, Not Applicable RESIDENTIAL iSingle and Duplex) Not Ready Date UNDERFLOOR (Plans) OK except N's 1. Zoning requirements -Setbacks -Easements 2. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. 3. Ftg., Garage; Soils -Steel- / /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel- / /" Ftg. 1 5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab 7. Piers -Fireplace Ftg.-Steel 8. O.W.V.: Fall -Fittings -Test -2 way C/0 -Sewer Test 9. Gas Pipe; Size -Anchors 10.Water Pipe; Test -Anchors -Regulator -Service Test 11.Electric; Underground 12. Plenums & Ducts; Clearance -Material -Support -Ins. 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date PLUMBING (Permit) OK except p's 14. Water Ht.; Vent -Access -Combustion Air 15. 16. Water Pipe; Test & Anchors -Nail Protection D.W.V.; Test-Fttngs & Anchors -Nail Protection 17. Shower Pan; Test, First Floor -Tub Access 18. Test Tub & Shower, 2nd Floor -Tub Access 19. Gas Pipe; Size & Anchors 52. Siding -Nailing -Veneer 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access Card -BI 54. Date Card -BI Date Card -BI 55. Shear Walls; Nailing -Bolts Date Card -BI Date Date ELECTRICAL (Permit) OK except q's 20. Fixture & Transformer Clearance -Ins. Protection 21. Elec. Receptacles Spacing -Lights & Switches at Doors 22. Size Boxes & No. of Conductors -Stapled Card -BI 23. Romex Installed Close to Edge of Studs & C.J. Card -BI 24. Equip. Ground made up w/Mech. Fasteners -Bond Gas & Water Card -BI Date 25. 2 Appliance Circuits in Kitchen & Conductor Size 56. 26. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 57. 58. 27. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al, Insulated Neutral []Yes El No 59. 28. Service -Riser Conductors & Ground -Main Disconnect 60. 29. 30. Equip. Clearances; Pane I S-Motors-Mech. Equip. Clothes Closet Light -Shower Light 61. Elec. Trim & Subpanel; Breaker Sizes -Labels Card B -I Date Card -BI Date Card B -I Date Card -BI Date Date MECHANICAL (Permit) OK except N's 31. A.C. Ducts; Insulation & Support 32. Vent Fan; Exhaust above Insulation 33. Condensate Drain & Overflow; Size & Grade 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet 35. Attic Access & Platform if Furnace in Attic Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date FRAMING(Plans) OK except q's 36. Sills; Proper Material & Anchors 37. Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound 38. Bearing Walls over Girders & Floor Nailing 39. Draft Stop in Walls (rat proof) 40. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 41. Header & Beam -Size & Bearing 42. Hangers -Post Caps -Anchors -Connectors 43. 44. 45. Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Sh_thng_.-Rfn_q_._ _ Fireplace Ties or Type A Flue -Fireplace Throat Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 46. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 47. Garage Fire Protection Framinq Date FRAMING (Continued) 48. Property Line Firewall & Openings 49. Ext. Doors -One 3' -Check Garage -3rd story, 2 exits 50. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 51. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 52. Siding -Nailing -Veneer 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access 54. Glazing Area -Glass Protection -Skylights -Plastic 55. Shear Walls; Nailing -Bolts Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date FINAL (Plans) OK except #'s 56. Ext. Steps -Door & Sidelight Protection -Landings 57. 58. Smoke Detector Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 59. Bedroom Exiting 60. G.F.I. & Bath Fixtures & Tub Access 61. Elec. Trim & Subpanel; Breaker Sizes -Labels 62. Stairs & Rails d3. Fireplace or Stove; Clearances -Hearth 64. Elec. Outlets at Wood Panel; Int. & Ext. 65. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance 66. Elec. Outlets & Receptacles at Kit. Counter 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper 69. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 70. Plb., Elec. & Mech. Equip. Listed for Location 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 72. Insulation -Foam -Looked in Attic E] Yes 73. Guard Rails & Deck Construction -Post Caps 74. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 75. Following instld.:Drive ❑ Yes E] No; Walks El Yes E) No; Planters ❑Yes ❑No 76. Stucco; Brown -Finish 77. A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 78. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 79. Water Well; Disconnect, Electrical, Plumbing 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground 81. Ventilation throughout House 82. Glass Protection 83. Corrections from Previous Inspections 84. Gas Test -Meters Tagged; Gas -Electric 85. Water & Sewer Connected -C/O to Grade -HD Approval 86. Energy Compliance Certificate -Other Certificates Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Comments at Final: (NOTE:Anentrymust be made each time youvisit jobsite) = .OK w = Not OK = Not Applicable MOBILEHOMES MISCELLANEOUS = Not Ready Date MOBILEHOME UTILITIES (Plans) OK except N's Date DEC , COVERS, CARPORTS, ETC. (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements nIng Requirements -Setbacks -.Easements 2. Soils; Special MH Support -Sketch 3. Sewer; Location -Test -Fall -C/0 -Concrete . Footings; Size -Depth -Spacing -Connectors 3. Decks,,,Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4. Woo Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Bracing 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete IXUM. Awn.; Columi- onnecti Splice -Decal -Enclosures 6. Gas; Location -Test -Wrap:/ /"L"ft./ /"Nat.or/ /"L"ft./ /"LPG 9. Carports; Windows -Doors 7. Utility Clearance 7. Elec. Card -BI Card -BI Date Card -BI Date Date Card -BI Date Card -BI Card -BI Date Card -BI Date Date o &1' Card -BI Date Date MOBILEHOME INSTALLATION (Plans) OK except N's Date POOLS (Plan OK/except N's 1. Zoning Requirements -Setbacks -Easements 1. Se" s -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH Test -Demand -Valve -Connector 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining 4. Electricity; MH Test -Crossovers -Breakers -Clearances 4. Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test -Fall -Flex Connector 5. Elec.; Pool Lighting; 15 volts-GFI 6. Water; MH Test -Regulator -Connector 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/O to Grade -HD Approval 7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Gas and Electricity Tagged 8. Elec,; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main in Conduit 9. Exits; Insp.-Sketch 10. Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test -Water Supply Test Card B -I Date Card -BI Date Card -BI Date Card -BI Date Card B -I Date Card -BI Date Card -BI Date Card -BI Date COUNTY OF BUTTE y - DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 5344541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE DEW A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. l InspectorI Date S COUNTY OF BUTTE-nDEPARTMENT OF PUBLIC WORKS j 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 APPLICATION AND PERMIT PERMI NO. os�� 5 ASSESSZR PARCEL NUMBER -� ZONIN BUILDING PERMIT RICHARD G. RAHN 5 P � l�% 7 SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 17 KAKANEE—KELLY RIDGE OROVILLE CA 95965 CONTRACTOR'S NAME SIERRA MOBILE SERVICE & SUPPLY TELEPHONE 1877-8 75 CONTRACTOR'S MAILING ADDRESS 8965 SKYWAY PARADISE CA 95969 Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation Is Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ , BUILDING ADDRESS - PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar Water Heater 20.00 OWater piping 5.00 LOT NO. 3 SUBDIVISION NAME UNIT 3 PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTURE SF ❑ Duplex ❑ Mobi lehome:] Other SPECIFY Building sewer 5.00 Mobile Home ISIG W1 10-00e TYPE OF WORK New] Addition Remodel❑ utilities Installation[--] Other E:1 Describe work: INSTALL 11tx33P ALUM PATIO AWNING ON FRONT MH; INSTALL $t6nx14t ALUM PATIO AWNI Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 (9ain service 00 AMP OR LOR ESS 10.00 ON PATIO SIDE Main service EA. ADD'L too AMP 2.50 NEW CONST. DWELLING OCCUP.& OR ADDNS. ( ACC, BLDGS. t 2/20sgft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check One): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the BuSlnesS and Professions Code and my license is in full force and effect. License No. 1 6 Classification C-61 ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEw CONSTR. LT' NON.RESID BRANCH CIRC ITS. 2,50 ea NEW CONSTR POWER APPARATUS IN NON.RESID. SINGLE OUTLET CIR. Ex. Occup(OUTLETS OR FIX/rURES BALO 0 Ex. Occu300 FIXED APPLNS, OR p. OUTLETS (RE51DJ EA.) 2.00 Temporary service 10.00 Mobile Home Facilixies 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor MECHANICAL PERMIT Filing Fee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ® I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shal I be deemed revoked. Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue ag t said County in consequence of the granting of this permit. X �A7✓,J r^' Date Signature of Applicant — Owner ❑ Contractor ❑ Agent R An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE OCCUP. GROUP I TYPE OF CONST. PARCEL PD 1__ND IssoE_ This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECT • OF PUBLIC BY PEREXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Dated 211 1-3s/� 7--Z J -- Receipt No. WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT �� +-�4 - - NOTE -,—All Materials & WorkmanshiO: Shall Be in Accordance with Recognized Gooc[!, Practices and of a quality prescribed for. the Spe'6'1fied use in the Uniform Building, Plumbing &. 'MRdWan e , i;i a I Codes and the National Electrical This set of plans and spec4;-~t;n,1s,.M.T.!1ST: be kept on the lob at all times and it is.0410wful to 1. 'hnncies or alterations on same without rJ In any permission from the Department'of P written Co Works, County )#lulle- A setback of 5 ft. from the property lines and a setback of 50ft. from the road f&&WA& 2CA centerline shall be clear of structures or equipment except v for a 2 ft. eave overhang. \v G. W 2 08 7 ;:a4 as °:: -BUTTE COUNTY BUILDING DEPARTMENT APPROVED.. VK /.I X_ Ferah harass band "VDG.Mscclb« Eusting-11 p nhaR odd >x•ua p \>nanl\o<AO Cont. oC s0 S.M. acra,.ya iNra o1\a...oia :.bs `'i"e,c. Awn;ng pnn \ :nauloak o*vroa. - ax ¢os�.a. �o"a4 C aBS.V .ear � b S.M. aa•a..ss N.ru � p3 .w.4 \ Co air rn CO_. 0.F, ma bars nd as aaa., . �Z r;b 4" e. s ICYa. M x•awa JSOF • 6 S.M. SCREVIS TO PENETRATE 1.5 POST FOR IS/e;• M1N. OR FmLIm_ POST GAP ORKKET oanl'r,, ' e ma b: \'\a APPROVED FOA 45C�UP\\iT, xl('m 614"a � 13"\NS\OE -LS' M:\\`E toopoa \'.. to\1e ^oi ba cuppor\nd by co\un,nc . tl105.M. aer<�es w Tmambar 7'. 5'., E.t•. i4•e.c• 1`la" .n., os sow, Pesci. 1.\ax \•^j o tMu..,n� oC R.i eaam,a F�% •^ .-.Ear[ - Alumn ium 1`oclena•s shell ba •L024T 4. All olhar5 Thnli ba poly s cod. plolad rl � ' 2 ep Va b.lts elp^,M,SG•Qn 4'e.a.oa Fw ? a,a; Ivminetl , ta.] d \na.a'\n r i I :I wa ns.a un roams. as a•�cnpe nqa- �Jl Q fi.acaal, as '• V41.mn. for 1'12'1 `'' iI Par poaf 3" Poaf o• I.a e.^a^.<nial pest. ss" ^ Pouf 'L •• bnh f IYa• V. p¢a1i ae• belt e. J el el0 SN S:.rs w•s fer 3" pc.T. : ,•a "F� TYP I 1 3:L• I rq• (ae.....gal 7r '. Y.P. . 30o4Nj6 A\om. , caa 1 6\a Cc, aa:\c`anacS Tana. VP.20ksi, Ult.a ]5rts:. S'. N, 6. � TNa 5' Cocain -.ey ba Asad ea iba Fre.1} bao and/er oa a^ agar nota- a{iocN;ng oifo �. aafol\6 s'or Cbofana rs a{c _ � 2.30• 'o drL I Splica, Saa I 01 Nela ap\ l i Materul: M�ncome N�GY. 0T\•'c\- .Tcn]. P. "-2e Xc.,U Moos n n .cba.va eC p.in1 PDltnrn.lI. neva B. r: r n r I.SO' ,per No}n: Ti,n 1' Fna.• , oy„ taTaa ft,a :30' moa ay,a R•.0-�-„e\\ Conn.. Sae i '7D• ,T g b splice, xa 1'1 _ Xo10 l0 b 1.1g- `rq j Me}arw\' nl� 30NL 041a e• 300AM`20 shah Mot•r:35 191, I M T Alum. 040' Ulf =35 k[i, M:n. Tanc.YP •38 ki: .040' lnickn•K, Na na.• R. R F. MNOA. a. Tai.... 1 AT TA REAM F.4«. _ N.r<.I.I: aooaT4 Al�....i.aae• upr a reJ.(83.1. Na30Va: ,N,n.Y.0a 1l 3"x4" EXTRUDED FASGIA ALTERNATE �¢r{.e .a'.'. p.sP 3-Sart\�\ or \`I `. `• ... r....«r ..�. _. , -. . 9..�a�. _ _. h t.l /4'holl ora of Ae lV oro aha �N,� ah'mw P<o.n F1ft<n rosx«I A- �5/1'min Pwm p'3 �^ Sc Ara ; f�d `M cmtar d qY �pF•�.. ppoot wt JF 3p'min.(Yplrar ♦alalO 8M 9rirab r!, y P«IY bow 3y va salt<e..n bel..r.h'n.in. veer• Por'/�•f•bol{ !'h• 'n0'h•. rw f• poet. t TF y4aba.r m - ac.•fl.��-/ i�: bdls�or a 7�'Iq".1°IB wo1\. Gtad oncMrc </ 2 ' R.R.R011a a o\ Pa<_ .I ns • ab. . _Qapp.wad a'e• n' Ca '.\aha•awe\oC '7.a0•gpaf\. M;n. �.. saga e'.zzon_n z' . uaa ave. P\n\aa - � •••.• i+aalanawea\,arDi+ep. .. _s _-L y4"d7., Eaiati,ISlak owd IP in rL:t •]Ab/ �. �i a moor L St..l. gees < ntlition M oopreua. ASTM A -.la 16" I 61 Tsn pots. by lha Bui Minq OFpici I, as oto 4. •-_____ a_ _ Gam(. POURED�OTI (STING SL ,FSn �nAn^"aa an\e:Po•neca.epe�aL oCia1 Cobr:aea;ora. 3.00 C0 .14'R si •1- TYP J f M-larial'.040 8004436, M e,.Tana. r. 1. • 28 Ma; Ult. c 3s Mai. Saa holt IS 3" POST Iola for ',b'butt. ,.ao ii �rmn I.zO^ I I 76 EJ�1i <( ' a Lend IOpsf, Nor: x.W i,,. lo,.P, W:nd Uplipl It3Pal ' 2. 9.�0 ) Saa nota B Alum. (2.se•¢rida) Malar 1316.0 a0'Ik:ca 30044 36 41.E' A.IYAIs10043T4 d:nV.0r2SksixUDaeOkal. - M.n. Tans I. "•/2OF a`O S.M. SCREWS ANO TO POST t6kai., U11.- 35k.L JSOF • 6 S.M. SCREVIS TO PENETRATE 1.5 POST FOR xRIM SMALL, NCT =AT V N OPTION A\_• A%o F_ FASCIA. •.1SE \'.F,' REOW000 dR YgIM FOR 1" F ASCIA OR 1"A Ia' D. F. TR\M_ - TRIM FORL 0V, S'F ASc1 A. SEE DETAIL_ AgovE sEi S.M. S, R. C`\ IB'O.C. FOR PANEL FASTENERS. FASCIA <( ' a Lend IOpsf, Nor: x.W i,,. lo,.P, W:nd Uplipl It3Pal ' 2. ko•:a. ,..�^d pPMad ie fwka al,a p.olaciad orao e(' n\\ N`a d" A4' REOw000 OR 'a OF .06p-.L.q a\Yq; (a069T/o NV,1M. CL\P O.F. PdSTS. YcE ANGLES EACH cA,ST ENED TO HEADER TA%LE FOR "•/2OF a`O S.M. SCREWS ANO TO POST 4P3aC\NQ. JSOF • 6 S.M. SCREVIS TO PENETRATE fmnc110 er amnspo.a„� r:,e�a P\ettia nui«..,eraiben IS/e;• M1N. OR FmLIm_ POST GAP ORKKET APPROVED FOA 45C�UP\\iT, LI Also a<naab\a q"hong w`11\ tun .amwad. 606371. Drat kcf-Za0" w7iUIL • 80 Mai. 1.5" POST BRACKET APPROVED q dtPEs 7Y.4: r- GENERAL NOTES <( ' a Lend IOpsf, Nor: x.W i,,. lo,.P, W:nd Uplipl It3Pal ' 2. ko•:a. ,..�^d pPMad ie fwka al,a p.olaciad orao e(' n\\ N`a c,E'J CcCF.EW _ _v Al\ PENET F.i\E al4manaa oC 1`oea eC` aaa owe�.ry iC opan or 40 �4.0 -;a-CL\�\A[AS WE\L AS META\PANEL 4•o[a oran'Cnnc\etad ,.i.\a,opan ,•,aaa, ;naa<a fmnc110 er amnspo.a„� r:,e�a P\ettia nui«..,eraiben :e.00' CJV EFAC.E nPPTo•ad soul anebs„ea . Enebtu<u .no\a•:o\ aa\o\\ 13"\NS\OE -LS' M:\\`E ^oi ba cuppor\nd by co\un,nc . �it -- �-'O• I nW 1y 3. Alumn ium 1`oclena•s shell ba •L024T 4. All olhar5 Thnli ba poly s cod. plolad rl ? .loin laa� laal. $.M. �[rau,c [M1all b< t1aa1. I I , Mln, adga dlsl;anca sa\.,\\ ba iwo d.> 4aTS - �'- \ .SO" .4S' R.• �4" R=.'tU'. � a Ce^c•<.< oto 1"ma<. n99 •• r S.2 sk yd. x T.S gni./sk., 1000 • pc• els,.a a. -J. aa•a-\cn\- R.•.\O,• V. foil ,hey ba eny e1ur31 oil o odium 1e .1 pit: -ft le a ort{ c \3Pai. eae 50o /"apC San nota \2. AC.R`I L\C PLASo, C_VOMM 4. Oe'4, CONFORMING TO \CFfO R.R. \004 0. ANamoaa e\\oys mny ba ucad pro..ldnd \�\ny ar Tyec o.R. raq;a\Arad \..;.\\, a\\a A\u,n. Aawc. Cer aq \e•q.aoiar auarontaad ,,:..,. u\\.4 Gans. y:ald sa.any4bs. Ma4e\' iaAck:, a iad ;[ ba•a ,•,a\o\ ens nagaA;va SK P!�NE� SPaa:.Q :a\ara�aa , • STe. (�\G\5� 9. Encn ,al ellelion baa. n idanliry,nq Coq enshall •jtvdlna n d edd.aae op . nuvee Fu: ars :nol n ,nba.<and SPA nambar�a¢a�9n\;xa+ooL4 .nd \aha a ,op\:Ca 12" I¢ng{N, Le a n i 43ac;g reO-A �4f';SYd� Sm •.:.1n R o4 ''4"bo\ka or <14 S. M, scra..as e5 and 11'Iq'tsrem o^a ona eQ aFA1ca . Te}o\ BQoa 4anar• pax tiP\;aa. Loania \nr,.;.aa\',n'ro'eQon,,,aax:exPes4 suPT». i sash, Le.a;e angman+ ui.1N ea Lao[\ a pasha. \oo a<a. Ca. eC 1ea� am,nna.. ora., •[. Eo•\\, Anc\ner may ba_ atad a^\` .r^ o ca Conti «.\ti c\oy b:nOar1 a.\ay nd 6 c\nyay fiend and s\,n\\ bn Ra. Ton on c\,e r. ' 94'. mac.. F_• b. i0" SI14 bo\1. Ucn \ ETO ..n.n_•,.,\ `t "r.\pSnPnl.-.a�aur a��\, \. EAF\T H ANCHOR -slaps _ BUTTE COUNTY s UILDING DEPARTM"q APPROV 4'.4` REDW000 PO St . 2 ov OLO". \`ly .l`lt 4C09TL< ALUM, CL\P L EACH FASTEO TO POST '^•/ i or •}'6 S.M. SCR. TO PENETRATE OK EOVA\- ANCNC0. BR ACa.ET APPROVED POR 6 -SOS UPUFT.� S" ANCHOR %0% -'TS SAME AS FOR Sa 16 DETP\\- ABOVG W000 TR\M $. ?0%7 DETP.\LS p-, cpocinq D. FEB 9 1004. ake.< SPA No M'3 -F1 Thh PIR. Amor ,. FEB $ 1 OBE Fano^115. 1ppccF d -q 1, on< cd9 K, m•nyly), �Pi..ak NnyTl, d er Fe<4mr NII ba ag 1 4. F1,a pre -e#ion r pt taaT IL rr 1 dad per rois�-1y i iff•<Am enl Adll s# Iu5# 1.e4 tlmea foe pJ.A, �j�i '/ � \ � or E• 9 ..,ry oa lip• � S¢a fa 5.••. Saa �\n}n \\. sa Rr ~ of ROBERT W. HAUSSLER REGISTERED STRUCTURAL ENGINEER ka. DW fiat. kls.a Ilw. OII0 da.moa DmE. _.a r%NPr,, 0:aa bkr<, -.ar. Ye.mtO, Mips. Ya rt, yls 14on:l:ra � loaf. Ikr Ibo, An wl Oka dY i® wr P+Dr+. •<raPa. w.m r •Nra 0 BOX 669 TEWLETOR CA 97465 005-779-3760 i. tln Ylnal u b laaonrtr d Or arvrr a:N msr ml d For side F..c ac .o MOBILEHOME Patti Po -rt AWNING STRUCTURAL PANELS 10 psf VEE PANEL 7422 ATTACHEDCALIF 9A645(7I4E 91-4N4i ROVE !' CAIJF 9E69! IG E754 -IQ) N PERMIT NO. 1240-85B PERMIT,EXPIRES LD OWNER RICHARD RAHN' CONTR. Sparks Const ASSESSOR PARCEL 69-21-05 LOCATION 17 Kokanee Drive, Oroville T a s �i j 1 Temp. Power Pole_ Called PG&E _ P Temp. Elec. Service Called PG&E Temp. Gas Se Called PC JOB FINALEI Signature OK = Not OK = Not Applicable MOBILEHOMES = Not Ready MISCELLANEOUS Date MOBILEHOME UTILITIES (Plans) OK except b's 1. Zoning Requirements–Setbacks–Easements Date DEC , COVERS, CARPORTS, ETC. (Plans) OK except q's Zoning Requirements–Setbacks–Easements 2. Soils; Special MH Support–Sketch o tings; Size–Depth–Spacing–Connectors 3. Sewer; Location–Test–Fall-C/0–Concrete 3 Decks; Girders and/or Joists–Decking–Bracing–Stairs–Rails 4. Water; Location–Test–Easement Needed (Sketch) 4, o—N7 o�Xw_n.; Posts–Beams–Rftrs.–Con nec.–Shthg.–Rfg.–Bracing 5. Electricity; Location–Clearances–Grnd.–/ / Amp–Concrete A. AlumAwn.; Columns–Connections–Splice–Decal–Enclosures 6. Gas; LocatiorrTest–Wrap:/ /"L"ft./ /"Nat.or/ /"L"ft./ /"LPG 6--CaaTports; Windows–Doors 7. Utility Clearance Alec. Card -B. Dates .G t Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date MOBILEHOME INSTALLATION (Plans) OK except Ws 1. Zoning Requirements–Setbacks–Easements Card -BI Date Date Card -BI Date POOLS (Plans) OK except N's '1 Setbacks–Easements 2. Footings; Size–Spacing–Marriage Line 2. Soils; Compaction–Structure Stability 3. Gas; MH Test–Demand–Valve–Connector 3. Pool Structure; Steel–Connections–Thickness–Dead Men–Lining 4. Electricity; MH Test–Crossovers–Breakers–Clearances 4. Elec.; Receptacles and Lighting; Distances–GFI 5. Drain; MH Test–Fall–Flex Connector 5. Elec.; Pool Lighting; 15 volts–GFI 6. Water; MH Test–Regulator–Connector 6. Elec.; Enclosures; Conduit Entries–Terminals–Listed 7. Water and Sewer Connected–C/0 to Grade–HD Approval 7. Elec.; Bonding; Metal w/5'–Circulating Equipment–Heater 8: Gas and Electricity Tagged 8. Elec.; Grounding; Equip. w/5'–Circulating Equip.–Pool Lghtg. Boxes–Enclosures–Panel boards–Ins. to Main in Conduit 9. Exits; Insp.–Sketch 10. Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test–Water Supply Test Card B -I Date Card -BI Date Card -BI Date Card -BI Date Card B-1 Date Card -BI Date Card -BI Date Card -BI Date = OK = Not OK ' = Not Applicable = Not Ready RESIDENTIAL '(Single and Duplex) - Date UNDERFLOOR Plans OK except #'s Date FRAMING (Continued) 1. Zoning requirements -Setbacks -Easements 48. Property Line Firewall & Openings 2. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth 49. Ext. Doors -One 3' -Check Garage -3rd story, 2 exits 3. Ftg., Garage; Soils -Steel- / /" Ftg. Depth 50. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 4. Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth 5. Stemwalls, Main; Steel -B lockouts -Wrapped -S lab 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab 51. 52. 53. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers Siding -Nailing -Veneer Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access 7. Piers -Fireplace Ftg.-Steel 8. O.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test 9. Gas Pipe; Size -Anchors 54. 55. Glazing Area -Glass Protection -Skylights -Plastic Shear Walls; Nailing -Bolts 10. Water Pipe; Test -Anchors -Regulator -Service Test 11. Electric; Underground 12. Plenums & Ducts; Clearance -Material -Support -Ins. 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date FINAL (Plans) OK except N's 56. Ext. Steps -Door & Sidelight Protection -Landings Card -BI Date Date Card -BI Date PLUMBING (Permit) OK except q's 14. Water Ht.; Vent -Access -Combustion Air 15. Water Pipe; Test & Anchors -Nail Protection 57. 58. Smoke Detector Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 16. D.W.V.; Test-Fttngs & Anchors -Nail Protection 59. Bedroom Exiting 17. Shower Pan; Test, First Floor -Tub Access 60. G.F.I. & Bath Fixtures & Tub Access 18. Test Tub & Shower, 2nd Floor -Tub Access 61. Elec. Trim & Subpanel; Breaker Sizes -Labels 19. Gas Pipe; Size & Anchors 62. Stairs & Rails 63. Fireplace or Stove; Clearances -Hearth 64. Elec. Outlets at Wood Panel; Int. & Ext. Card -BI Date Card -BI Date 65. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance Card -BI Date Card -BI Date 66. Elec. Outlets & Receptacles at Kit. Counter Date ELECTRICAL Permit OK except q's 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper 20. Fixture & Transformer Clearance -Ins. Protection 69. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 21. Elec. Receptacles Spacing -Lights &Switches at Doors 22. Size Boxes & No. of Conductors -Stapled 70. Plb., Elec. &Mech. Equip. Listed for Location 23. Romex Installed Close to Edge of Studs & C.J. 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 24. Equip. Ground made up w/Mech. Fasteners -Bond Gas & Water 72. Insulation -Foam -Looked in Attic F] Yes 25. 2 Appliance Circuits in Kitchen &Conductor Size 73. Guard Rails & Deck Construction -Post Caps 26. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 74. 75. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes Following instld.: Drive ❑ Yes ❑ No; Walks E3 Yes ❑ No; Planters ❑Yes []No 27. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al, Insulated Neutral ❑Yes CJ No 28. Service -Riser Conductors & Ground -Main Disconnect 76. Stucco; Brown -Finish 29. Equip. Clearances; Panels-Motors-Mech. Equip. 77, A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 30. Clothes Closet Light -Shower Light 78. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 79. Water Well; Disconnect, Electrical, Plumbing 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground Card B -I Date Card -BI Date 81. 82. Ventilation throughout House Glass Protection Card B -I Date Card -BI Date Date MECHANICAL (Perrr.it) OK except q's 83. Corrections from Previous Inspections 84. Gas Test -Meters Tagged; Gas -Electric 31. A.C. Ducts; Insulation & Support 85. Water & Sewer Connected -C/O to Grade -HD Approval 32. 33. Vent Fan; Exhaust above Insulation Condensate Drain & Overflow; Size & Grade 86. Energy Compliance Certificate -Other Certificates 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet 35. Attic Access & Platform if Furnace in Attic Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Comments at Final: Date FRAMING(Plans) OK except q's 36. Sills; Proper Material & Anchors 37. Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound 38. Bearing Walls over Girders & Floor Nailing 39. Draft Stop in Walls (rat proof) 40. Fire Stops; Furred Ceilings-Stairs-Chases-Tob 41. Header & Beam -Size & Bearing 42. Hangers -Post Caps -Anchors -Connectors 43. 44. Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Ring. _ Fireplace Ties or Type A Flue -Fireplace Throat 45. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 46. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 47. Garage Fire Protection Framing (NOTE: An entry must be made each time youvisit jobsite) COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 APPLICATION AND PERMIT ASSE SOR PARCEL NUMBE D j ZOG N BUILDING PERMIT OWN R XC /1 .e d TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 11'a 0 4-- �f'o v• e'9l CONTRACTOR'S NAME TELEPHONE CONTRACTOR'S MAILINGA DRESS Q, Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ 0i 9 115-0 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ /5 Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUILDING ADDRESS co -`v PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar Water Heater 20.00 Water piping 5.00 LOT NO. �� 3 SUBDIVISION NAME Z% 2j"1 P PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 -5 outlets 5.00 USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome AOther SPECIFY Building sewer 5.00 Mobile Home S I G I W 10-00e TYPE OF WORK New W Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe work: e S — Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 6100V OR 00 AMP ORSLESS 10.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. I DWELLING OCCUP.& OR ADDNS. % ACC. BLDGS. 2t/EPSgft CONTRACTORS LICENSE LAW I declare der penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full fo ce and effect. S3B �I 2 License No. �,- Classification ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR U TI.OUTLET 2,50 ea NON•RESID BRANCH CIRC ITS NEW CONSTR POWER APPARATUS &) NON.RESID. SINGLE OUTLET CIR. Ex. Occu / 20@50e P\o TS OR FIXTURES SAL@30 FIXED Ex. Occup. FIXED TS (REAPPLS. OR P• OUTLETS (RESID.) EA. 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): �' permit is for $100.00 (valuation) or less. have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3,00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequenc f the granting of this permit. XDate S-- — � Sv Signature of Applicant - wner ❑ Contractor 2 Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 storiesin height. Mobile Home Installation Fee $ TOTAL PERMIT FEE 41 S OCCUP. GROUP I TYPE OF CONST, ��—JV,PARCEL PD HD ISSO This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRE R 2 LIC By. �' PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date Receipt No. 432c(� S.:) WHITE-D.P.W.. YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT LOT 3 UNIT 3 NOTE:—All Materials &.Workmansh�-- S' Accordance with Recognized Good %,00- ices an of a quality prescri6eJ for the Specified us6`tiq the Uniform Building, Plumbing & Mechanical Codes dam. the National ElectAra) C-o4o, This set of plans and specifications MUST lie. kept on the job cit all time's and it is unlawful to make any Ganges or alterations on some without written p n ermission ffbvn t6 of Public %mgq, Courity of Aid4e- A setback of 5 ft, from the property lines and a setback / i of 50ft. from the road AVA*Vfitf,, #16) centerline shall be clear of 41 structures or equipment except for a 2 ft. eave overhang. Q / � 0 / i a ot F,-.A5f4W4,-Wr— APPROVED BUTTE COUNTY BUILDING DEPARTMENT 07EI Top rail to be 36 in. high with in. �errnecliafe rails to be 'not wer 1e *in. -aporf. T X jy8) N! -z)< 6 c: A P 3 3c(p 48d., . BUTTE COUNTY - BUILDING DEPARTMENT APPROV*Fn t PERMIT NO. 774-85P E(MH) PERMIT EXPIRES 3 Icze -Zo 4 a OWNER RICHARD G. RAHN CONTR.Sparks. Const ASSESSOR PARCEL 69-21-05 LOCATION 17``Kokanee Dr; lot 3, KR#3, Oroville ( Temp. Power I _ • _ OFFICE COPY Called P' _ Address _ Temp. Elec. c GAS Called P M By Date ELECTRIC Meter By �(�,'_ - -Dateq--2z-,- Temp. Gas Se �r Called PG&E JOB FINALED (Date)-d� Signature MOBILEHOME INSTALLATION ACCEPTANCE COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS — 7 COUNTY CENTER DRIVE OROVILLE, CALIFORNIA — 534-4541 Address or location of mobilehome Owner's name Owner's address Insignia or hud number Manufacturer's name Serial number of V.I.N. (Official Approving Installatio PERMIT NO.'' Year of manufacture (Date) IF THE MOBILEHOME IS MOVED OR RELOCATED, THE MOBILEHOME INSTALLATION ACCEPTANCE SHALL BECOME INVALID. THIS FORM SHALL NOT BE USED WHEN THE MOBILEHOME IS INSTALLED ON A FOUNDATION SYSTEM. 5138 White - Owner, Yellow - Installer, Pink - D.P.W. Y COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751' 7 County Center Drive, Oroville — Phone: 534-4541 Skyway and Elliott Road, Paradise -- Phone: 872-2961, Ext. 57 CORRECTION NOTICE ER T A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. Inspector J' = OK 0 = Not OK Not Applicable MOBILEHOMES MISCELLANEOUS * = Not Readv / I I Date MO HOME UTILITIES (Plans) OK except N's Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except N's 1'Requirements—Setbacks—Easements 1. Zoning Requirements—Setbacks—.Easements Soils; Special MH Support—Sketch 3. Sewer; Location—Test—Fall-C/0—Concret L) 2. Footings; Size—Depth—Spacing—Connectors 3. Decks; Girders and/or Joists—Decking—Bracing—Stairs—Rails Z _ . Wat ; Location—Test—Easeme Needed (Sketch) 4. Wood Awn.; Posts— Beams— Rftrs.—Connec.—Shthg.—Rfg.—Bracing lectricity; Locaypu--CTe nces—Grr�� AmC-1& re 5. Alum. Awn.; Columns—Connections—Splice—Decal—Enclosures /'Nat.or/ /"L"ft./ /^LPG 6. Carports; Windows—Doors Utility Clearance 7. Elec. i Card -BI Dat Card -BI Date Card -BI Date Card -BI Date Card -BI at _ [ —&S Card -BI Date Card -BI Date Card -BI Date Date MOBILE ME INSTALLATION (Plans) OK except k's Date POOLS (Plans) OK except #'s 1 on' Requirements—Setbacks—Easements 1. Setbacks—Easements 2, ooti g—Marriage Line j 2. Soils; Compaction—Structure Stability Gas; MH Test—Demand—Valve—Connector 3. Pool Structure; Steel—Connections—Thickness—Dead Men—Lining le ricity; MH Test—Crossovers—Breakers—Clearances 4. Elec.; Receptacles and Lighting; Distances—GFI 5 r 'n; MH Test—Fall—Flex Connector 5. Elec.; Pool Lighting; 15 volts—GFI 6. "r: MH Test—Regulator—Connector 7. W "r and Sewer Connected—C/0 to Grade—HD Approval 6. Elec.; Enclosures; Conduit Entries—Terminals—Listed 7. Elec.; Bonding; Metal w/5'—Circulating Equipment—Heater and Electricity Tagged its; Insp.—Sketch II 8. Elec.; Grounding; Equip. w/5'—Circulating Equip.—Pool Lghtg. Boxes—Enclosures—Panel boards—Ins. to Main in Conduit 10r.' Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test—Water Supply Test Card B -I Date Card -BI Date ',Card -BI Date Card -BI Date Card B -I Date Card -BI Date 'Card -BI Date Card -BI Date I - )K = Not OK Not Applicable RESIDENTIAL (Single and Duplex) Not Ready Date UNDERFLOOR Plans OK exce t#'s Date FRAMING (Continued) 1. Zoning requirements -Setbacks -Easements 48. Property Line Firewall & Openings 2. 3. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth Ftg., Garage; Soils -Steel- / /" Ftg. Depth 49. 50. Ext. Doors -One 3' -Check Garage -3rd story, 2 exits Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 4. Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab 51. 52. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers Siding -Nailing -Veneer 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access 7. Piers -Fireplace Ftg.-Steel 54. Glazing Area -Glass Protection -Skylights -Plastic 8. D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test 9. Gas Pipe; Size -Anchors 55. Shear Walls; Nailing -Bolts 10.Water Pipe; Test -Anchors -Regulator -Service Test 11.Electric; Underground 12. Plenums & Ducts; Clearance -Material -Support -Ins. 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -BI Card -BI Date Card -BI Date Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date FINAL (Plans) OK except q's Card -BI Date Card -BI Date Date PLUMBING (Permit) OK except q's 14. Water Ht.; Vent -Access -Combustion Air 56. Ext. Steps -Door & Sidelight Protection -Landings 57. 58. Smoke Detector Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 15. Water Pipe; Test & Anchors -Nail Protection 16. D.W.V.; Test-Fttngs & Anchors -Nail Protection 59. Bedroom Exiting 17. Shower Pan; Test, First Floor -Tub Access 60. G.F.I. & Bath Fixtures & Tub Access 18. Test Tub & Shower, 2nd Floor -Tub Access 61. Elec. Trim & Subpanel; Breaker Sizes -Labels 19. Gas Pipe; Size & Anchors 62. Stairs & Rails 63. Fireplace or Stove; Clearances -Hearth Card -BI Date Card -BI Date 64. 65. Elec. Outlets at Wood Panel; Int. & Ext. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance Card -BI Date Date Card -BI Date ELECTRICAL Permit OK except q's 66. 67. Elec. Outlets & Receptacles at Kit. Counter Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper 20. Fixture & Transformer Clearance -Ins. Protection 69. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 21. Elec. Receptacles Spacing -Lights &Switches at Doors 70. Plb., Elec. & Mech. Equip. Listed for Location 22. Size Boxes & No. of Conductors -Stapled 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 23. Romex Installed Close to Edge of Studs & C.J. 24. Equip. Ground made up w/Mech. Fasteners -Bond Gas & Water 72. 73. Insulation -Foam -Looked in Attic E] Yes Guard Rails & Deck Construction -Post Caps 25. 2 Appliance Circuits in Kitchen &Conductor Size 26. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or At 74. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 27. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al, Insulated Neutral ❑Yes ❑No 75. 76. Following instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑Yes ❑No Stucco; Brown -Finish 28. Service -Riser Conductors & Ground -Main Disconnect 29. Equip. Clearances; Panels-Motors-Mech. Equip. 77, A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 30. Clothes Closet Light -Shower Light 78. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 79. Water Well; Disconnect, Electrical, Plumbing 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground Card B -I Date Card BI Date 81. 82. Ventilation throughout House Glass Protection Card B -I Date Card -BI Date Date MECHANICAL (Permit) OK except N's 31. A.C. Ducts; Insulation & Support 83. Corrections from Previous Inspections 84. Gas Test -Meters Tagged; Gas -Electric 85. 86. Water & Sewer Connected -C/O to Grade -HD Approval Energy Compliance Certificate -Other Certificates 32. 33. Vent Fan; Exhaust above Insulation Condensate Drain & Overflow; Size & Grade 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet 35. Attic Access & Platform if Furnace in Attic Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date FRAMING Plans OK except q's Comments at Final: 36. Sills; Proper Material & Anchors 37. Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound 38. Bearing Walls over Girders & Floor Nailing 39. Draft Stop in Walls (rat proof) 40. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 41. Header & Beam -Size & Bearing 42. Hangers -Post Caps -Anchors -Connectors 43. 44. Cing. Joist-Rflr. Ties-Purlin-Roof Brac.-Truss-Sh_thng_.-Rfng_.__ Fireplace Ties or Type A Flue -Fireplace Throat 45. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 46. 47. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions Garage Fire Protection Framing (NOTE: An entry must be made each time you visit jobsite) Fri COUNTY OF BUTTE -DEPARTMENT, OF PUBLIC WORKS W- , PEPMIT Nb`1 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 APPLICATION AND PERMIT ASSESSO6 F3 P CEL M=E$ 1 yV] '"G -` j BUILDING PERMIT OWN t TELEPHON S.Q. FT. CCC. BUILDING VAL'U tIDN OWN R' MAI ING A DR SS r v CONTR T�OR'SE v s TELEPHONE CO T C G ADDRESS Fireplace CO STRUC ION NDER UNKNOW Total Valuation $ Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUILDING AD tTES5 PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar Water Heater 20.00 Water piping 5.00 LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTURE SF [:1Duplex❑ Mobilehome�Other SPECIFY Building sewer 5.00 Mobile Home S G W TYPE OF WORK �-, New ❑ Additio Remodel F1 utilities ElInstallationE/ Other [J Describe work: �- i �� ��� Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. / DWELLING OCCUP.e,\ OR ADDNS. 1 ACC. BLDGS. // 2t�iQSQft CONTRACT RS LICENSE LAW I deplare under penalty of perjury (check one): �am licensed under provisions of Chapt. 9, Div. 3 of the Bushes$EX. and Professions Code and my license is in full force a d effect. License No. �Y� 7 Classification G ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR TI -OUTLET No .RE SID, BRANCH CRCITS 2.5QeaNEI CONSTR POWER APPARATUS &) NON-RESID. �$INGLE OUTLET CIR. DCCUp(OUTLETS OR FIXTURES BA50 300 FIXED APPLNS, OR Ex. OCCUp- OUTLETS (RESID,) EA,) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate o Consent to Self -Insure. shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. �_ C X ��� Date S d Signature of Applicant — Owner ❑ Contractor k��Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ S , TOTAL PERMIT FEE $ , OCCUP. GROUP I TYPE OF CONST. PARCEL .PD HD SSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECT OF PUBLIC BY PER T EXPIRES Date_�� the applicable provi- resolutions to do fees have been paid. WORKS _�J Date q -17p �J /_C? Receipt NO._ _3 7 (� 3 WHITE-D.P.W.� YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT BUTTE COUNTY.DEPARTMENT OF PUBLIC WORKS " 7 County Center Drive, Oroville. CA. PHONE: 534-4541 MOBILEHOME INSTALLATION SHEET 1. Owner's name:�- 2. Installer's name: 1-7116 3.' Is the site currently under permit? Yes No _1 ( If yes, .furnish permit number `7' — g ) OR ! Is the site an existing site? Yes / / No (If yes, furnish two (2) plot plans.) 4.' Will the mobilehome be located at least 5 ft. away from septic tank and leaoh fields and clear of. all setbacks and easements? Yes / No ( If no, clarify ) 5. What is the mobilehome electrical rating? ----------------------- .2 o G Amps 6.' What is the mobilehome site service rating? --------------------- ° G Amps. 7.. What is the mobilehome site'circuit breaker rating? ------------- '� ° G Asips, 8. Is there any other electric load -to be served by the mobilehome siteservice? ------'--------=------------------------------------ Yes No T.. (If.yes, identify the load and size: (Load) (Amps). T� 9. What is the mobilehome site gas pipe size? ---------------------= 10. What is the type of gas service? --=----:---------------------- Natural 7 % LPG -I- 11. What is the gas pipe length from meter or tank to the mobilehome? (ft.) 12. What is the mobilehome gas demand? ------------------------------ (BTU), { (This information not required if pipe length less than 6 ft. on natural gas or less than 50 ft. on LPG.) / � tJ � _vr_ BUTTE COUNTY BUILDING DEPARTMENT APPROVED MOB ILEHOME .SUPPORT DATA If other than single wide, Mobilehome Mfr. `� furnish Setup Model No. �- 3 Year Ydidth (ft.) Box Length��(ft.) Tagalong or Expando Size ft. x ft. (SHOW SUPPORT DETAILS BELOW) On all mobilehomes manufactured after October 7, 1973; furnish manufacturer's installation manual and structural setup sheets (if not on file with the County of Butte). All center supports measured from front of mobilehome unless otherwise specified. Footings (check one) Single 1. Wood either pressure treated or foundation grade. x30 (ft.)(in.) (in.) (in.) ❑ 2. Other: (specify) Center support locations* Center support footing sizes Supports (check one) (in.) ❑ 1: Concrete block. Sr x11 .2: Other.. (specify) (ft.)(in.) (in.) (in.) E ---Tagalong or Expands,' show support details. (in.) (in.) Win. Typical Support in.) Footing Size r x (ft.)(in.) (in.) (in.) Max. Pier Spacing �/D (ft.) (in.) 66'0 *If center piers are other than drawn above, draw in -locations, spacing, and dimensions. (ft.)(in..) -- Max. Overhang COUN"i Y OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 _ APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER Q. A/.._ 0:,BUILDI ZONIN , PERMIT OWNER /e Q TELEPHOWE SQ. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 6 & /% CONTR ACTORR''S NAME TEL ONE �7 CONTRACTOR'S MAILING ADDRESS `� br -.71 �; ,n Fireplace CONSTRUCTION LENDER Z UNKNOWN Total Valuation $ Filing Fee $ LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE No. Plan Checking Fee $ Q ' Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ 0O BUILDING ADDRESS , PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar Water Heater 20.00 Water piping 5.00 LOT NO. It v/3 SUBDIVISION NAME 1 ,e/% 6' a PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 US OF STRUCTURE SF [:]Duplex❑ MobilehomeEOther SPECIFY Building sewer 5.00 Mobile Home G 4:FO:O:e,,. TYPE OF WORK-- New ❑ Addition ❑ Remodel ❑ Utilities R Installation ❑ Other ❑ Describe work: Permit Fee $ Qe Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 .S NEW CONST. (/ DWELLING OCCUP.& OR ADDNS. l ACC. BLDGS. I 2/20Sgft CONTRACTORS LICENSE LAW I declare der penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification R_ El 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR ULTI.OUTLET 2,50 ea NO N.RESID BRANCH CIRC ITS NEW CONSTR. POWER APPARATUS &') NON-RESID. SINGLE OUTLET CIR. Ex. Occu zo@50* o OR FIXTURES Bw P�l@30 FIXED APLNS Ex. Occup. OUT LETS P(RESID )REA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $so Contractor MECHANICAL PERMIT Filing Fee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, ju gments, costs, and expenses which may in any way accrue unty in cc sequence of the granting of this permit. a tns r___,02-10 XDate Sg ure o Applicant — Owner E] Contractor E]Agentwork An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ a, OCCUP. GROUP TYPE OF CONST. PARC P K ISSU This permit is hereby issued under sions of the Butte County Code and/or indicated above for which DIREC ORIOF PUBLIC BY ` PE T EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date 7-7,1 '�� r 7 ���' Receipt No. J WHITE-D.P.W., YELLOW-ASSESS9R, PINK -INSPECTOR, GOLDENROD -APPLICANT Return to DPW NOT COMPARED W! �® 17548 ORIGINAL D OFFICIAL RECO ; AGRICULTURAL STATEMENT OF ACKNOWLEDGEMENT3i� ; � )V is �i�I -Y- CAi.t FOR RESIDENTIAL DEVELOPMENT Sedtion 26-8.1 of the Butte County Code requires this acknowledgement�R be recorded prior to issuance of a building permit. E(-EANUR M. BECKER The property described herein is adjacent to land or included CLERK - hr'COetUCR within an area zoned for agricultural purposes, and residents of FEE this property may be subject to inconveniences or discomfort arising from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers;rhnd from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occa- sionally generate dust, smoke, noise, and odor. Butte County has established agricul- tural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: Lot 3, as shown on that certain map entitled, "KELLY RIDGE ESTATES UNIT NO.3", which map was filed in the office of the Recorder of the County of Butte, State of California, July 26, 1974 in Book 43 of Maps, at pages 44, 45, 46, 47 and 48. Subject to all easements, rights of way and restrictions of record. Date: May 23, 1984 (2-ZZ,A W4 _'A P" Richard G. Rahn PROPERTY OWNERS--�—' Dor6thy L. Rahn State of California ) On this the 23rd- day of May f 19 84 SS. before me, the undersigned Notary Public, personally County of Butte ) appeared ****Richard G. Rahn and Dorothy L. Rahn, proved to me on the basis of satisfactory evidence to be know-nxtoxmaxtuxba the person(s) whose name(s) are subscribed to the within instrument and.acknowledged iq that they executed the same for the purposes NOTARY FURUC-C�UFO:ZVIA c��r Courtj therein contained. r� Atiy Commission Expires March 2, t986 IN WITNESS WHEREOF, I hereunto set my hand and official seal. Notary PublIA Present A.P. N0. S Roan! 0zk. Drive. C`r•�vMe CA. 95965 IF) Telephone 533.2000 North Burbank Public Utility District 1960 Elgin Street OROVILLE, CALIFORNIA 95965 10-85 DISTRICT APPROVAL AND VERIFICATION OF INSPECTION BUILDING SEWERS This verification form must be submitted to the Butte County Department of Public Works - Building Department prior to issuance of a building or occupancy permit, whichever is applicable. Prior to final approval by Butte County of a Building or an Occupancy Permit, a copy of this verification form, signed off by North Burbank Public Utility District, must be submitted to Butte County. Applicant: Rip -hard Ct & naro_tb1z L Rahn cnn;71 e CartPr,) Applicant Phone No.: 9,38 5041- Property 041Property Location (s): 17 Kokanee Drive A.P. No. (s): 69-21-05 ees Paid: $700-00 Regional Fav-J-Iity Char-ge- Due. Application for service approved: March 8, 1985 North Burbank Public Utility District Inspection(s) made and successful test(s) observed: Location: M Date: North Burbank Public Utility District release to close permit: Date: By; LOT 3 UNIT 3 n....02 / VE This set of plans and specifications MUSlc� kept on the job at all times and it is unlawful, toNOTE.-,—All Materials & Workmanship Shall Be iri make any changes or alterations on same without Accordance with Recognizes! Good Practices and wriften permission from the I.epartment of Public o{lity prescribed for the Specified use in the Works, County of Butte. Uniform Buil m inq & Mechanical Codes and the National Electrical Go— 10 120.11 L = 34,:17_. I� 1IL A sotbarik of from the property lines and a setback / of 50ft. from the road KDI404"IL i�.106 centerline shall be clear of S� / structures or equipment except 6) - for a 2 ft. eave overhang. r�J. yofkfte 6-4S &�;ctior shall be within 4oiehome, either in or within the rearo dside (left) of the {i up SQ. FT. MiMit, FOR A90B1LE� A pe; iw ill I tol' tion of h, T I e required or the the 6611.yme. 70 0 0 f b If 0 -77 BUTTE BUTTE COUNTY BUILDING DEPARTMEN-5 �'.2 ✓cam � .:= i2 =is- ��s . _..._ .._: APPROVED. �r AP # 9 —Z I —0 OWNER PERMIT'# / f� MH UTIL.CLEARANCE DATE INSPECTOR ELECTRIC GAS. Support Struc. Compaction Test Re . Service .Size Other. Load Type Pipe Size Length YESI NO YES NO �UO hip stsiu Ea tTJ tea, is �q°x1s'm� Fva"t M and Np'rE' A1� eeo1'ed "• e a[tce c,�ith .. t, <q `3Lst7UiOl3 ING+G(12'Cl n�Cl'� 1C' of aF�In n r1nnbing "T�1Ood�e- � in 'e taat�,in°°Wj� God � I� s eet of pia. t kept on the�ob Q lr,�ap°cmca�ona, mm maks �Y ch �� d it is T be Writte-n mea or al f utile-,';� to P$ salan fe ,none on acme Litho '��r]ce �untrmen.g of ut Butte. .PUbJk structures or equipment excep for a 2 ft. eave overhang. zs sG. 4 F.A.5rcol I;W f 1 _N� Mos ILEHOME ,su PPOIT DATA 1 If other than single wide 3 �� Year Mobilehome Mfr._ `a�?� /� furnish Setup Model No. )didth (ft.) Box Length D _(ft•) Tagalong or Expando Size ft. x_____, ft. (SHOW SUrTO1tT_ DETAIL, BELOW) . . On all mobilehomes manufactured after October 7, 19I3, furnish manufacturer's installation le with.the County of Butte). manual and structural setup sheets (if not on fi All center supports measured from front of mobilehome unless otherwise specified. ootin s (check one) • Single d .pq x- (ft.)(in.) (in.) (in.) enter support Center support locations* footing sizes (in.) S� 3 x (ft -)(in.) (in.) (in.) ® in . (in.) (ft.) (in.) (in.) /' o (ft.)(in.) I � (ft.) (in.) 6 , off *If center piers are other than drawn above, draw in-locatious. spacing, and dimensions. 1'. Wood either pressure.treated or foundation grade. 2. others (specify) u ort• , (check one) E] 1: Concrete.block.., •2. Other. (specify) *—.Tagalong or Expando,' show support details. A x, --Z -- Typical Support in. (in.) Footing Size �'� 6•r -- Max. Pier Spacing Max. Overhang t l Ell I AC'H" :MM–,,•I I ACMr SEAM I o t; i I I I I I i I I I I I JkEISMIC FIE" FOUNDAI AW I I Q T T T OUTLINE .w OF MON, COACH I DOUBLE WIDE TYPICAL _ 20', 24', 26' OR 25 - DOUBLE LE WIDE MOBILE COACH Scall: I" - 10' OT FOR MORE THAN TRIPLE WIDE UNITS. SUBMIT LAYOUT TO THARP k ASSOC. FOR APPROVAL. STANDARD TIER k FOOTING SPACING PER MOBILE HOME MANUFACTURER'S INSTALLATION MANUAL, CONFIGURATION SHOWN 13 THE MINIMUM NUMBER OF PADS REQUIRED. MR. STANDARD PIER k FOOTING SPACING PER MOBILE HONE MANUFACTURER'S INSTALLATION MANUAL. CONFIGURATION SHOWN IS THE MINIMUM NUMBER OF TADS REQUIRED. ELEVATION NOT TO SCALE 11 Til PIERAL NOTES: COACH 1 SEAM RZPERENCZ: CALIIORNIA CODE O! REGULATIONS, TITLZ 23 AND U.A.C. U94 EDITION. 3' X 3" PLATE 1 _ 1. DESIGN LOADS: Lb E 4 - 3/S' " '+ VZWICAL LIVB LOAD O SZLSMIC LC 11 �E%L'Ltj MAX TUBE HEIGHT S ' SHORT TUBE BOLTS l71NC � > �� . ROOF <: .: WIND �• '. o 14' LONG TUBE j';I II •,. 4 - 3/8' STD RIPE I 30 Mf;u E �B°PR :;` �} 4 BOLTS TIGHTEN Im rI O 3/16' PLATE , v ry USEISMIC 1 PIERS B FOUNDATION PADS CLAMP OUTLINE OF MOBILE COACH (Wj � j SjNGLE HIDE TYPICAL —; A_N_f SINGLE WIDE MOBILE Scale: 1" - 10' COACH MR. STANDARD PIER k FOOTING SPACING PER MOBILE HONE MANUFACTURER'S INSTALLATION MANUAL. CONFIGURATION SHOWN IS THE MINIMUM NUMBER OF TADS REQUIRED. ELEVATION NOT TO SCALE 11 Til PIERAL NOTES: COACH 1 SEAM RZPERENCZ: CALIIORNIA CODE O! REGULATIONS, TITLZ 23 AND U.A.C. U94 EDITION. 3' X 3" PLATE 1 _ 1. DESIGN LOADS: I g. THE =AND RME W" "FORT ASSEMBLIES IFAI-RC2 OR APPROVED ZQUVAILNT AND SHALL BZ LISM AND 1 ALA1WlD COAmY CERTIFIED TRSTINO ANDDCCO UMMNO 2 - 3/8' x 1' BOLTS SERVICE/ (CTC) FOR THZ FOLLOWING !AAD.: FIELD DRILL HOLES OPTION OF LATERAL: 1700 Eb. MAX 4 - N14 TEX STS COACH C IL VER11CAU 13000 Bir. MAX OR J BEAM 7. THIS FOUNDATEON IS FOR. PLACING MANUFACR7RZD WILDING! CONSTRUCTED WITH LONOL'fUD1NAL OR 1 / 4'x 2' x 4' 3' x 3' CROSS IOINTIL ANGLE 3' WIDE PLATE !. TILLt FOUNDATRON riaN d DISKiNED To BIS CONSIR[JCI ED oN A FAIRLY UVEL liiZ WITH NO E3(1! TING BOIL PROBLEMS, IF ISZT[umm OCCURS DUZ TO POOR SOIL, on I Nm P. 1/2' 9. IN AREAS WI'Mk1 DIFFERENTIAL IFITLEMENT (D.S.) CAN OCCUR, MANUFACTURED HOMES SHALL BE 4 - BOLTS SEISMIC READJUSTED WHEN D.S. ZXCEZDS V4", OR WHEN IT WILL ADVIRSK Y AFFECT THt' U81 OF TIBL PIER MANUFAC71=D HOMIL 10. THIS SYSTEM US ADACTABLII TO STANDARD HOUAW MASONRY BLOCK PERI. I I. FOR ROOF UM LOAN OF UP TO i0 nF. THIS FOUNDATION SYSTEM MAYBE USED WITH THE, NUMBER OF C.r. TYPICAL BEAM 1198MIC PIERS PL I SHOWN ON TIMAN' HOWEVER. ROOF LOADS HIOHERTHAN 30 PSP MAY REQUM THE USR OF AWITIONAILS'TANDARD ?AD AM Ptp "TOM AS PZRTHZ MANUFAC'TURZR'S INSTALLATION MANUAL. I FOIINDATIONI PAD NOUS: i CONNECTIONS _ _ :F+. PLYWOOD _ Not to Scale M 1 ; FOUNDATION PAD MAY f;Z USED AN ALTERNATE. PItECAiT ��� POU�IDATI FAO. 2. FOUNDATION 1 PADS SHALL BZ PLACED ON L.ZVZL UNDISTURBED SOIL 12 SQ IN OVERSIZE fOR CHIPPING 3. CONCIM AND DR CC BREAKAGE 8 • a _ 3000 Poll AT 28 DAYS AS TESTRD AND MANUFACTURED SY STARIJI1 WZIGHT CONCRZTL ►. MEMRM PAD ION ORM;rATWIMU EVZR PMIBLZ IS THAT THE LONO DWZNSION OF THE PAX) >u FERrONDICULAR TO THE COACH BWM (AS SHOWN ON THZ PLAN} INSERT f R WHERIE FIELD CONDITEONS REQUIRE PAD ROTATION, NO MORE THAN HALF OF THE PADS INA 5/0' x 1 1/4' Kt. TRAVIBRfZ IRM CAN U ROTATZD So THAT M LONG DIMWIION OF THZ PADS AUrARALtEL TO • 8' 24' THZ 0OAIrH SLAM. 4. lSI1='FIMA'['4!D PL-Y11WD FOUNDATION PAD 3/4 INCH A.F.A. 404 EXTERIOR r RL -S3 CC. PLUGGED. NZR • QA 397, PRP•101. I 36 1/2" Sir• X I3/6'n= STAINLESS l WHIR INS[R7 3.5' 4x4 -4x4 WVf 1 PRECAST CONCRETE FOUNDATION PAD 301x3210/4' PLYWOOD HOLES FOR 1/2' x 2 1/2' C.D. 11'02'0/4' PLYWOOD SCALE, 1' = 1.5' x x x ti 7 x x x x 3/4' PLYWOOD SHEETS SCREWED TOGETHER WITH 12 NS x 1 1/2' FHWS 6' x i" 32' ---"1 ALTERNATIVE PLYWOOD FOUNDATION PAD SCALE, 1'=1.5' COACH SIZE ;NOTES: 1. MAXIMUM LENGTH OF SINGLE WIDE COACH - fS FW. 2. MAXIMUM LENGTH OF DOUBLA WmZ COACH - 70 FENT. 3. UNLESS APPROVED BY TILARP A ASSOC, FLOOR TO RMOZ HEIGHT NOT TO ZXCEZD: a S FM FOR NINOLZ WIDE COACLIZS k 10 PEST FOR 20' DOUBLE WIDZ COACHES 12 POST FOR 24, 2f, A 21' DOMA WWI COACiRi 4. PORTR11u WLLIBOOACIOS, POU.OW $AMR PLACEMENT PATTERN AS SHOWN ON THZ DOUNA WITH MOBIIi COACH. S. FOR ANY COACH SIZZ OTHER THAN AS IHOWN ON THIS PLAN OR RMFERZNCED ABOVC, ,i HZ PIER AND PAD LAYOUT SHALL B; I RMW19D AND APPROVED BY DONALD M. THA" A ASSOAAT11S. REAM SIZE NOTES: I 1. SPACING SHOWN ON THIS PLAN AM FOR COACHZS WITH 10 INCH AND 12 INCH BZAMS OR S INCH PACO CORRUGATED BZAML 2. ANY OILIER R INCH BEAM W NOT TO CANTILZVER MOPE ULAN 6.0 FZZT ON EACH ]IND OF UNIT AND !PACING OF 8UPAIC PIERS CAN NOT EMM 13.3 FZZT. O&F*44twd IQAY044r *% rhrM ' •A.'AUN AM 3r►J11'>t +CCKIE.. {E(1Kry T�t A00It0V'F0 f m*C3 ro C4Rr4tillo"rS 1`40"01 � M.T � .M+�,Nr iu.. ,•e. rpAonr+ to drMMM U .wM« r«4pwww-+w ul W#*r %6% S04041 I+t.w «xl NB. M NQ, stmv 91 Cmsa:Nt Or CC*tS AN'C STANOA41*X 0 a t e ('Z�4� • I �� ��* ��� i.J f .ti QF Elf A P ' [,%;q "an S W*0 E 4*0 ....Ld����� RENEWAL OF <l41W6, TO J0 -5p„ STATE STIRMTTTAIIS 304F AND 30-51 REVISIONS I By IN y 4 O 0 P4 00 O U 0Qc0� pQq �4�ob N C 0 Date 09/08/97 Scale As Shown Drawn JLT Job 95-36 Shoat 1 Of l Sheets 4 - 3/S' " '+ VZWICAL LIVB LOAD LATEI[AL LL1R LOAD SZLSMIC MAX TUBE HEIGHT S ' SHORT TUBE BOLTS > �� . ROOF <: .: WIND �• '. ZONE 14' LONG TUBE 2' DIA •,. 4 - 3/8' STD RIPE 30 Mf;u E �B°PR :;` �} 4 BOLTS TIGHTEN O 3/16' PLATE , v ry SO >, 1 To 1Bo CLAMP IN -POUNDS LOAN !HALL BE CONSISTENT WITH ROOF LIVE LAAD, WIND LOAD, AND SZISMIC ZONE AS TORQUE 2. THE DESIGN MABLISHWPM?MtMANENTB=INGWMUNASPZCIPCLOCALARZA 3/4' THREADED 3/1i' PLATE LEGS - ROD TYP OF 4 3. TM pOUNDATION 19 CONSIDm D To CON$TnUR A FIRM ANWT f0t"ATION. ARI TO BE SUPPORTED RY FUN!, UNSATpRATM UNDWI`UIWD COHNIVII W1I, POOTIN05 ARIL 4. ALL FOOTVKIS FOR 1000 toy TOTAL ,AAD SOIL PRESV*1 AND SHALL BZ COMPATMIS WrM LOCAL SOIL �� 5/1L' PLATE DESIGNED 5/1' X 1 1/4' DOLT CONDITIONS. WITH HARDENED WASHER S. S rRVC 1vR SEISMIC PIER Not t O S C a 1 e �L� co r UpM TPD A {c IF - 35 K$I MISPECIFICATIONS. j PATENT PENDING •. SHALL BZ WELDED ACCORDING TO ANS SrlCUICATIOTIS: L EI.ECTILODSS: m C.P. SEISMIC PIER # 1 - IL PLATES: ASTM A36 UL ANCHOR BOLTS: ASTM A307 NOTES iM. HOLT!: SAE ORS.An M A449i-ASTM A323 �• THREADEDROM COLD DRAWN LOW CARBONWEWAWZ Ito IN -POUNDS IS EQUIVALENT TO 15 FT -POUNDS A AIL METALCOKUONEI'TTS INCIAIINNO NAIU A SCRZWS Z'TC. ARZ TO BZ PROTECT M COATED. I g. THE =AND RME W" "FORT ASSEMBLIES IFAI-RC2 OR APPROVED ZQUVAILNT AND SHALL BZ LISM AND 1 ALA1WlD COAmY CERTIFIED TRSTINO ANDDCCO UMMNO 2 - 3/8' x 1' BOLTS SERVICE/ (CTC) FOR THZ FOLLOWING !AAD.: FIELD DRILL HOLES OPTION OF LATERAL: 1700 Eb. MAX 4 - N14 TEX STS COACH C IL VER11CAU 13000 Bir. MAX OR J BEAM 7. THIS FOUNDATEON IS FOR. PLACING MANUFACR7RZD WILDING! CONSTRUCTED WITH LONOL'fUD1NAL OR 1 / 4'x 2' x 4' 3' x 3' CROSS IOINTIL ANGLE 3' WIDE PLATE !. TILLt FOUNDATRON riaN d DISKiNED To BIS CONSIR[JCI ED oN A FAIRLY UVEL liiZ WITH NO E3(1! TING BOIL PROBLEMS, IF ISZT[umm OCCURS DUZ TO POOR SOIL, on I Nm P. 1/2' 9. IN AREAS WI'Mk1 DIFFERENTIAL IFITLEMENT (D.S.) CAN OCCUR, MANUFACTURED HOMES SHALL BE 4 - BOLTS SEISMIC READJUSTED WHEN D.S. ZXCEZDS V4", OR WHEN IT WILL ADVIRSK Y AFFECT THt' U81 OF TIBL PIER MANUFAC71=D HOMIL 10. THIS SYSTEM US ADACTABLII TO STANDARD HOUAW MASONRY BLOCK PERI. I I. FOR ROOF UM LOAN OF UP TO i0 nF. THIS FOUNDATION SYSTEM MAYBE USED WITH THE, NUMBER OF C.r. TYPICAL BEAM 1198MIC PIERS PL I SHOWN ON TIMAN' HOWEVER. ROOF LOADS HIOHERTHAN 30 PSP MAY REQUM THE USR OF AWITIONAILS'TANDARD ?AD AM Ptp "TOM AS PZRTHZ MANUFAC'TURZR'S INSTALLATION MANUAL. I FOIINDATIONI PAD NOUS: i CONNECTIONS _ _ :F+. PLYWOOD _ Not to Scale M 1 ; FOUNDATION PAD MAY f;Z USED AN ALTERNATE. PItECAiT ��� POU�IDATI FAO. 2. FOUNDATION 1 PADS SHALL BZ PLACED ON L.ZVZL UNDISTURBED SOIL 12 SQ IN OVERSIZE fOR CHIPPING 3. CONCIM AND DR CC BREAKAGE 8 • a _ 3000 Poll AT 28 DAYS AS TESTRD AND MANUFACTURED SY STARIJI1 WZIGHT CONCRZTL ►. MEMRM PAD ION ORM;rATWIMU EVZR PMIBLZ IS THAT THE LONO DWZNSION OF THE PAX) >u FERrONDICULAR TO THE COACH BWM (AS SHOWN ON THZ PLAN} INSERT f R WHERIE FIELD CONDITEONS REQUIRE PAD ROTATION, NO MORE THAN HALF OF THE PADS INA 5/0' x 1 1/4' Kt. TRAVIBRfZ IRM CAN U ROTATZD So THAT M LONG DIMWIION OF THZ PADS AUrARALtEL TO • 8' 24' THZ 0OAIrH SLAM. 4. lSI1='FIMA'['4!D PL-Y11WD FOUNDATION PAD 3/4 INCH A.F.A. 404 EXTERIOR r RL -S3 CC. PLUGGED. NZR • QA 397, PRP•101. I 36 1/2" Sir• X I3/6'n= STAINLESS l WHIR INS[R7 3.5' 4x4 -4x4 WVf 1 PRECAST CONCRETE FOUNDATION PAD 301x3210/4' PLYWOOD HOLES FOR 1/2' x 2 1/2' C.D. 11'02'0/4' PLYWOOD SCALE, 1' = 1.5' x x x ti 7 x x x x 3/4' PLYWOOD SHEETS SCREWED TOGETHER WITH 12 NS x 1 1/2' FHWS 6' x i" 32' ---"1 ALTERNATIVE PLYWOOD FOUNDATION PAD SCALE, 1'=1.5' COACH SIZE ;NOTES: 1. MAXIMUM LENGTH OF SINGLE WIDE COACH - fS FW. 2. MAXIMUM LENGTH OF DOUBLA WmZ COACH - 70 FENT. 3. UNLESS APPROVED BY TILARP A ASSOC, FLOOR TO RMOZ HEIGHT NOT TO ZXCEZD: a S FM FOR NINOLZ WIDE COACLIZS k 10 PEST FOR 20' DOUBLE WIDZ COACHES 12 POST FOR 24, 2f, A 21' DOMA WWI COACiRi 4. PORTR11u WLLIBOOACIOS, POU.OW $AMR PLACEMENT PATTERN AS SHOWN ON THZ DOUNA WITH MOBIIi COACH. S. FOR ANY COACH SIZZ OTHER THAN AS IHOWN ON THIS PLAN OR RMFERZNCED ABOVC, ,i HZ PIER AND PAD LAYOUT SHALL B; I RMW19D AND APPROVED BY DONALD M. THA" A ASSOAAT11S. REAM SIZE NOTES: I 1. SPACING SHOWN ON THIS PLAN AM FOR COACHZS WITH 10 INCH AND 12 INCH BZAMS OR S INCH PACO CORRUGATED BZAML 2. ANY OILIER R INCH BEAM W NOT TO CANTILZVER MOPE ULAN 6.0 FZZT ON EACH ]IND OF UNIT AND !PACING OF 8UPAIC PIERS CAN NOT EMM 13.3 FZZT. O&F*44twd IQAY044r *% rhrM ' •A.'AUN AM 3r►J11'>t +CCKIE.. {E(1Kry T�t A00It0V'F0 f m*C3 ro C4Rr4tillo"rS 1`40"01 � M.T � .M+�,Nr iu.. ,•e. rpAonr+ to drMMM U .wM« r«4pwww-+w ul W#*r %6% S04041 I+t.w «xl NB. M NQ, stmv 91 Cmsa:Nt Or CC*tS AN'C STANOA41*X 0 a t e ('Z�4� • I �� ��* ��� i.J f .ti QF Elf A P ' [,%;q "an S W*0 E 4*0 ....Ld����� RENEWAL OF <l41W6, TO J0 -5p„ STATE STIRMTTTAIIS 304F AND 30-51 REVISIONS I By IN y 4 O 0 P4 00 O U 0Qc0� pQq �4�ob N C 0 Date 09/08/97 Scale As Shown Drawn JLT Job 95-36 Shoat 1 Of l Sheets