Loading...
HomeMy WebLinkAbout069-470-037BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #:(530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #:(530) 538-7541 FAX#: (530) 538-2140 WEBSITE: www.buttecounty.net\dds PROJECT INFORMATION Site Address: APICA CT APN: 069-470-037 Owner: ADAM AND NICOLE HUEY Permit NO: 06-1695 Issued Date: 10/10/2006 By KEJ Permit type: RESIDENTIAL 25 HUNTER DR Subtype: SFD-Custom/Model OROVILLE, CA 95966 Expiration Date: 10/10/2007 Description: NSF/GAR/DECKS(OPEN & COV) (530) 533-1821 Occupancy: R-3 Zoning: AR -1 Contractor Applicant: Square Footage: JOHN WHEELER CONSTRUCTION ADAM AND NICOLE HUEY Building Garage Remdl/Addn PO BOX 5262 25 HUNTER DR 2,989 1,060 OROVILLE, CA 95966 (530)534-5449 OROVILLE, CA 95966 (530)533-1821 Other Porch/Patio Total 61 364 4,474 FEE INFORMATION County Impact - SFD $2,244.02 Dwelling - Custom, Model $2,104.14 Fund 10 BLDG $1,512.74 Impact Processing Auditor $50.00 Impact Processing DDS $50.00 Res Impact Fees - SFD $2,005.09 SMTP - Residential $22.62 Total Charged: $8,083.61 Fees Paid: $8,083.61 SRA Fees $95.00 Balance Due: $0.00 Receipt No: B449 LICENSED CONTRACTOR'S DECLARATION OWNER / BUILDER DECLARATION ` " Contractor (Name) State Contractors License No. / Class / Expires JOHN WHEELER CONSTRUCT 586797 / / I HEREBY AFFIRM UNDER PENALTY OF PERJURY that 1 am exempt from the Contractor's License Law for the following reason (Sec. 7031.5), Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code] or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]; Please check one of the following: I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. X 10/10/2006 Contractors Signature ' Date -11. AS OWNER OF THE PROPERTY, OR MY EMPLOYEES WITH WAGES AS THEIR SOLE COMPENSATION, WILL DO THE WORK, AND THE STRUCTURE IS NOT INTENDED OR WORKERS' COMPENSATION DECLARATION OFFERED FOR SALE (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of the property, who builds or improves thereon, and who does the work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: ❑I HAVE AND WILL MAINTAIN A CERTIFICATE OF CONSENT TO SELF -INSURE FOR WORKERS' COMPENSATION, as provided for by Section 3700 of the Labor Code, for the year of completion, the owner -builder will have the burden of proof that he or she did not build or performance of the work for which this permit is issued. improve for the purpose of sale.). ❑I HAVE AND WILL MAINTAIN WORKER'S COMPENSATION INSURANCE, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My Workers' Compensation insurance carrier and policy number are; ISI I, AS OWNER OF THE PROPERTY, AM EXCLUSIVELY CONTRACTING WITH LICENSED k2�I CONTRACTORS TO CONSTRUCT THE PROJECT (Sec. 7044, Business and Provessions Code: The Contractor's License Law dows not apply to an owner of the property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractor's Licensb Law.). Carrier: Policy Number: Exp. Date: (This section nee not be competed if the permit is for one hundred dollars ($100) or less.) ❑ I AM EXEMPT under Section B. & P.C. for this reason: CERTIFY THAT IN THE PERFORMANCE OF THE WORK FOR WHICH THIS PERMIT IS ISSUED, I shall not employ any person in any manner so as to become subject to the Workers' �""�I Compensation laws of California, and agree that if I should become subject to the workers' X 10/10/2006 compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Owners Signature / Date X �j 10/10/2006 I hereby certify that I have read this application and state that the above information is correct. I agree to comply with all City and County ordinances, rules, regulations, and State laws relating to building construction, and with any and all conditions of permit. I agree to defend, indemnify, and hold harmless Butte County, its officers, agents and employees from any and all claims and liability for personal injury, including death, and property damage caused by, arising out of, or in any way connected with the issuance of this permit. I hereby acknowledge that issuance of this permit does not authorize the use or occupancy of any sidewalk, street, or subsidewalk. I hereby authorize representatives of Butte County to enter the above mentioned property for inspection purposes. I hereby certify that I am the property owner or am authorized to act on the property owner's behalf. 1,/ W 10/10/2006 Signature Date WARNING: FAILURE TO SECURE WORKERS' COMPEN TION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL P ALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST AND ATTORNEY'S FEES. CONSTRUCTION LENDING AGENCY • 1 HEREBY AFFIRM UNDER PENALTY OF PERJURY that there is a construction lending agency for the performance of the work for which this permit is issued. (3097 civ. code) Mime of Permittee [SI N] Print Date [ [X [ Owner 1:1Contractor OR; Agent for Owner ❑Agent for Contractor �''� FILE COPY Lenders Address City State Zip t22.v2 S'KP DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION AND SUBMITTAL REQUIREMENTS 24 HOUR INSPECTION#: OROVILLE: (530) 538-7636 • CHICO: (530) 891-2834 OFFICE #: (530) 538-7541 A FEE WILL BE REQUIRED AT TIME OFAPPLICA TION Website: www.buttecounty.net/dds O6 **PLEASE PLEASE PRINT CLEARLY" C OWNER INFORMATION Last Name � jxfsmus First a e Address Wn4r Dr City } State Zip ,� Phone �-3 � 1$ a1-4 Fax E-mail Fax c ���5�/�Gl J C CONTRACTOR Name � jxfsmus Address State Address Phone City ya v State Zipy�-Y Phone � Fax c ���5�/�Gl J E-mail Li 7 Class/9 C APPLICANT INFORMATION ARCHITEC /ENGINEER Name � jxfsmus Address State City Phone State Zip Phone Book Fax E-mail Planner State License Number APPLICANT INFORMATION Name Address s I, City v Ave State Zip 9� 7 Phone Fax E-mail APPLICANT SIGNATURE X For office use only: Z. Zoning 4Oce PMrodd�,,lsA.\_Cityccg Flood Zone Ave SRA I Yes No Occ. Type Const. Subdivision Name Map Book I Page Lot # Planner Date Approved: OVER FOR SUBMITTAL REQUIREMENTS PERMIT NO. (� BPOW WV15 BIN # 0_Q PROJECT LOCATION. AP# l — 4Oce PMrodd�,,lsA.\_Cityccg �,leA_ Ave WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address Description or Scope of Work: Sq FT- Livin 98 Garag olope Cov ❑ Structure -Built wit out Per its ❑ Proposed Change of Occupancy (Note previous use): EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after the date of application. In order to renew action on an application after expiration, a new application, plans and fee will be required. REQUEST FOR REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made prior to the expiration of the permit and no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. II Received by:Y,(l„-1(U"Amount:� I'11.1<.� l!� Bldg I I Receipt #.m '4%�y x SRA D Date: �. ! 2 -(�' ^� Other 1 c��{{�� c-� j� t 1 V�� / l Total SUBMITTAL & PERMIT REQUIREMENTS The following drawings and specifications must be submitted to the Building Division in order to apply for a p ejyA it. INCOMPLETE SUBMITTALS WILL NOT BE ACCEPTED. ALL PLANS MUST BE LEGIBLE AND IN INK. Cir 1. Site plansl`3 or 4 sets, signed by the preparer of the plans. No graph paper! p 2. Complete 1ansl3J r 4, sots, signed by the preparer of the plans (No graph paper!) OR --Z vEngineered plans .3, or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. V3. Engineered truss details and layouts in duplica (if required). No faxes! 4. Energy compliance design and supporting documentation in u IFc . ❑ 5. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 6. Manufactured homes: (A) Installation manual, (B) Marriage line info, (C) Floor Plan, (D) Tie down or fnd plans, all in duplicate ❑ 7. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate (if required). ❑ 9. Site plan and business license approval from the City of Biggs. ❑ 10. Letter of intent for non-residential buildings. ❑ 11. Building Permit Application Without Required Clearances Form ❑ 12. Hazardous Material Form (for Commercial Buildings only). Remaining items needed to issue the permit. Additional items may be required after Plan Check and Planning review (May require additional plan review upon receipt of the following items.) ❑ 1. Agricultural Buffer clearance and site plan approval from the Ag Commissioner's office (if required). ❑ 2. Impact Fees. ❑ 3. California Department of Forestry plan approval (if required). ❑ 4. NPDES Form. ❑ 5. Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). ❑ 6. Contractor's license information. (Number, Name Style, Classification). ❑ 7. Worker's Compensation Carrier and Policy Number. ❑ 8. Owner -Builder Verification (if required). ❑ 9. Letter of Signature authorization (if required). ❑ 10. Recorded copy of Agricultural Acknowledgment Statement. ❑ 11. ❑ Legal description from current recorded grant deed, ❑ Copy of MA. Title, Title transfer, or MCO. ❑ 12. Sanitation and site plan approval from the Environmental Health Department. l If you have questions or would like additional information regarding this process, please contact a Permit Assistant at (530) 538-7541. EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after date of application. In order to renew .action on an application after expiration, a new application, plans and fees will be required. REQUEST FOR FEE REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made within two years from the date of fee payment on permits not issued, and two years from the date of permit issuance for permits issued; however, on issued permits refunds can only be made if no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. OVER FOR BUILDING PERMIT APPLICATION KAFORMSWILDING F0RMS\B1dgApp1SubRgmts.doc Page 2 of 2 REV 8-12-05 COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA .95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET r n ���` �` I OWNER: �I . ASSESSOR PARCEL NUMBER O lnq -q' / o '03q Proposed Building Use: NSF Dwel I l n Permit Technician: Date: 7� 13 OCo ItggfnJs required in orde o,apply for a permit. All box6s MUST,be checked OR marked NA in order to apply. � `� XW 1. Site plan 3 or 4 sets, signed by the preparer of the 0ans.1- ❑W N 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. 3. Engineered plans, 3 or 4 sets, with wet signature on plans ANC>�2 sets of stamped and signed calculations. 4. Engineered truss details and layouts in duplicate. No faxesl 0 5. Letter from Engineer or Architect for truss design review. 1J 6. Energy compliance design and supporting documentation in duplicate. ❑ 7. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 8. Manufactured homes: (A) Installation manual, including marriage line info, (C) Floor Plan, (D) Tie down or fnd plans, all in duplicate. ❑ 9. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 10. Flood Elevation Certificate, wet -stamped and signed, in duplicate. Neu11. Hazardous Material Form Neu 12. Acknowledgement of building permit application without required clearances. ❑ 13. Other 1 7 "'Fire'Sprinklers m§ heeded to -issue the permit. (May require additional plan ieviiew upon receipt of the following items.) Sanitation and site planapproval from the Environmental.Health.Department in ❑ Chico D"Oroville, as applicable .... .... u K `J; � :.. . ❑ 16. Agricultural Buffer clr and site plan apr from the Ag Commissioner Sent by ❑ 17. Soils Report and/or Engineered Foundation required ........................................... 0 18. Erosion Control Plan Required........................................................................ 19. Fees as shown on the attached Schedule of Fees Due Sheet .............................. 20. City of Chico Plumbing permit........................................................................ 21. Site plan and business license approval from the Cty of Biggs .............. 22. California Department of Forestry plan approvapaid. Sent by: 7 C 23. Planning approval for (A) Use: dL (B) Parking: (C) Parcel Check:.6f�..�.. (� ❑ 24. Contact Land Development about _ Improvements, _ Drainage ........................ o� 25. Fire Marshall Review (commercial projects only). Sent by: ...................... 26. NPDES Form ................... .......... ....:........................................................... ❑ 27. Encroachment Permit for driveway from the Public Works Dept ........................... ❑ 28. Contractor's license information. (Number, Name Style, Classification) ................... ❑ .29. Worker's Compensation Carrier and Policy Number .......................................... ❑ 30. Owner -Builder Verification (_ Given to owner, _Mailed to owner) ..................... 31. Letter of Signature authorization.................................................................... 32. Recorded copy of Agricultural Acknowledgment Statement ................................. ❑ 33. Existing violations and/or expired permits......................................................... Cl34. Deed Restriction.......................................................................................... 35. ❑ Legal description, ❑ M.H. Title, title search, registration or MCO ......................... 36. Other: G(no+ iwed - Proof 04 0►><tncr11D 37. Other: When issued Telephone 5-a 3 - / 8A ! and hold for pickup. I have been informed of the above items and requirements for obtaining a building permit. Applicant: 7 Date: 7-1,3 1. Index permit application for the ite n mbe Plan Check Letter 2. Additional items required Contractor, designer, owner, waeadvigd of th a ve ata by ❑ ph e, mail, ❑ counter, by Date: Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Contractor, designer, owner was advised of the ab a ata by ❑ phone, ❑ mail, ❑ cou r y Date:-- Plans reviewed by: Date: Plans approved by: Date: Structural reviewed by: Date: o Structural approved by: Date: 2 Note transfer by: Date: Yellow: Building Division K/Building/Plan Check/Data Sheets/data sheet page 2 9.27.05 Plot Plan Attached Floor Plan Attached Sent to 8D/1)S I ^l _ TO: Building Division = Developmeni�Seivices FROM: Environmental Health SUBJECT: Sanitat'on Clearance 7a--03 7 Owner tocation AP# Plan Approved for:. 'SeWage Disposal: Water Supply: Public Private Well Clearance fordwelling. Other Hold final for: Final clearance O.K. for: NOTE: Envirb'fimentdl Health S Building Clearance 9/2005 PLO Date BUTTE COUNTY bEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE, CA 95965 www.buttecountV.net/dds PHONE (530) 538-7541 FAX 538-2140 RECEIPT OF FEES SCHEDULE - RESIDENTIAL Owner App Date HUEY 711']17nna APN No: 069-470-037 Permit Type: Subtype: Permit No: BP 06-1695 Permit Desc: �New 1 BUILDING PERMIT FEES ESTIMATED AT APPLICATION Plan Check portion of Permit Fee 2 FEMAYes Flood Elevation Review $109.98 3 SRA* x Yes Fire Plan Check - Non -Refundable $95.00 (State Responsibility Area) Building Inspection $109.98 NON-REFUNDABLE portion of fees due at application $3,506.90 $1,402.76 $2,104.14 Balance of Building Permit Fee $95.00 $204.98 $109.98 $1,497.76 FEES DUE AND PAYABLE AT TIME OF PERMIT APPLICATION ,$ ,,607.74 FEES (BELOW) DUE PRIOR TO ISSUANCE OF PERMIT $6,475.87 $2,104.14 $22.62 RECEIPT � DATE Tech/Asst Cn20' L _ 7/13/06 Kourtni 4 5 6 7 7a Balance of Building Permit Fees (from No. 1 above) SMTP* - Strong Motion Instrumentation Program (Enter amount from permit system) Additional Plan Check Fees (NON-REFUNDABLE) Other*: Other*: 8 IMPACT FEES - RESIDENTIAL* Applications After 04/15/06 R-3 7604.091 6198.041 7289.40 1Per Dwelling MFD Per Dwelling DRAINAGE FEES* CHICO STORM DRAINAGE MASTER PLAN County 1 4249.11 3183.54 3238. 772 Little Chico Creek $9,088 Chico Urban Area 6146.23 4538.82 5648. 776 Mud -Sycamore Creek $6,275 EI Medio Fire District 3249.97 2385.76 2422. Temporary Dwelling 1 $136 At time of building permit $136 annual renewal fee for first 4 renewals. Not to exceed $684. North Chico Specific Plan 9 10 10a 11 11a A SR -1, SR -3, SR-1/PD 8801.091 7395.041 8486.40 RECEIPT DATE Tech/Asst $4,349.11 RECEIPT DATE Tech/Asst F_ 0 R-1 8897.09 7491.04 8582.40 ti° R-2 8390.091 6984.041 8075.40 R-3 7604.091 6198.041 7289.40 Processing Fee is automatically added to impact fee total 1 $100.00 WATER TENDER FEE (Not collected when impact Fees Applicable( Enter Bat.# $200.00 DRAINAGE FEES* CHICO STORM DRAINAGE MASTER PLAN 770 Butte Creek $7,997 771 Comanche Creek $8,341 New construction, vacant land, on 1 acre or less - Enter 1 or less acre value 772 Little Chico Creek $9,088 773 Big Chico Creek $6,776 774 Lindo Channel $8,267 775 SUDAD Ditch $7,211 776 Mud -Sycamore Creek $6,275 777 PV Ditch $8,893 More than 1 acre, existing buildings - fees to be assessed by Public Works Fee Determination Sheet Needed - Enter amount determined by PW THERMALITO DRAINAGE AREA $684 Maximum Per each new living unit on existing lots where full drainage fees have not been paid Temporary Dwelling 1 $136 At time of building permit $136 annual renewal fee for first 4 renewals. Not to exceed $684. PROOF OF PAYMENT OF FEES (BELOW) MUST BE RECEIVED PRIOR TO ISSUANCE OF PERMIT. Forms will be prepared after plan check is completed for applicant to take to respective district office. 12 SCHOOL DISTRICT FEES* I Oroville Elementary 091 12a RECREATION DISTRICT FEES' I Oroville I / -RI In At the time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. These fees may be changed during the plan checking process. •Applicant:Date: Pursuant to Governmen ode Section 66020, yo ' are hereby tified those Items followed by an "" may have been imposed on your project. You have 90 days from the date of approval of the porject or from the impostio f the above referenced items during which you may protest. The requirements for a protest are specified in Goverment Code Section 66020(a). K:/Building/Forms/Schedule of Receipt Fees Residential 041506 BUTTE 90UNTY (DEVELOPMENT FEE CERTIFICATION FORINT FEATHER.RIVER RECREATION AND PARK DISTRICT (FRRPD) ❑ CHICO AREA RECREATION AND PARK DISTRICT (CARD) ❑ PARADISE RECREATION AND PARK DISTRICT (PRPD) ❑ DURHAM RECREATION AND PARK DISTRICT (DRPD) Assessor Parcel Number (s) 0 �� ` "70 0? l Building Permit Number Property Owner (s) Project Location /Address A o n Subdivision Name Assessable Sq. Ftge qg� Type of Residential Development (check one) New Development _�ZSingle Family -Detached Single Family -Attached Alteration/Addition(s) Non -Residential to Residential Multi -Family Dwelling Mobile home Mobile home replacement verified by Assessor Department Demo Permit (date issued ) verified by Building Department Comments: 10-g-0 Co Bui ding Department R esentative Date XFRRPD64-(X�'D PRPD ❑ DRPD certifies that: a e - Applicant Name T Phone Number 1, `h Mailing Address J-2 State Zip Has complied with requirements of the Butte County Board of Supervisors Resolution No. by Payment of: Dwelling Units @ $ Square Feet @ $ _ Remarks: Paid by Check No: — Recreation and Park District Paid by Cash: ve per unit for a total of $ per sq foot for a total of $ Receipt No: Uate - G� BUTTE -COUNTY SCHOOLS IMPACT,FEE CERTIFICATION FORM (One form per Building) School District 0 rovillt Fjmm4cl Building No. A.P. Number CO- Jurisdiction: =.City Building Property Owner Out Property Location/Address Subdivision Lot No. Residential Development M No of Living Units Commercial/industrial o New Sq. Footage C1 ?--A Mobile Home Addition/ *Supplemental to (Group. R) Installation Conversion Permit # *(N6 foundation inspection) .......................................................................... =1 Addibon Deed Restricted Sq. Footage (Attach a signed copy of Deed Restriction and Notice of Limited Use Facility document), District Identification No. —1 —1 9, -M (Street Sq. Footage Date t School District certifies that ItA4 (Applicant) (including Exterior Roofed Areas) (Phone Number) CPI (City) (State) (Zip Code) has complied with the requirements of Resolution No. 6'5 — 06 —0 q by payment of $ --I g' 6 representing eA square feet. School rB 2921 6 $ ULL M ULL MITIGATION Paid by Check # $ Remarks: 0 to A 4 ,m —3 7 Date Notice: You may protest the Imposition of the fees Identified above by submftdng a written protm.to On District. In compliance Whh Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the Imposition of On few In any*court action. R, subsequent to the School District Representative sWdng Oft Butte County Schools Impact Fee CoMeadon Form, the School District to notified by the applicable Local Planning Agency that this project Is being reviewed under the C&Hfornla Environmental Quaft Act (CEQA). this project may be subject to additional school fen to fully midgate Its Impact an the school district's schools. White (school district), Yellow (building department), Pink (applicant). feelonnift (305W= DECLARATION REGARDING ACCESS I, A. applicant for a 'H u,4 1fl permit from the County of Autte for the parcel of land identified asAssessor's Parcel Number 0VI "176 - r) �3 7 , declare that said parcel was created on by deed recorded in Book at Page under Serial. Number a of 8 7 j of Official Records in the office of the County Recorder of'the County of Butte, and that I first purchased an interest in said parcel on or about old O 60 , and that at that time I was not aware of any facts that would cause me to suspect that said parcel may have been created without the access, thereto, required by law. I declare under penalty of perjury that the foregoing is true and correct. Executed this _3 day of (��10--c 202Co, at OF -'?a , California. Signature FA W:\LD Documents\LD Fortes\Declaration regarding access I1 A Print name OCT 0.;� DEVELO1Pi k,, SERVICFc QlCORDING REQUESTED BY: Fidelity National Title Company of California Escrow No.: 06 -108398 -TG Locate No.: CAFUM958-0958-0001-0000108398 Title No.: 06 -108398 -BEE When Recorded Mail Document and Tax Statement To: Mr. and Mrs. Adam Huey 25 Hunter Drive Oroville, CA 95966 APN: 069-470-037 GRANT DEED BUTTE COUNTY RECORDER 3� SERIAL NO. AAVO(O " RECORDED AT THE REQUEST OF FIDELrrY NATIONAL TrrL CO. DATE RECORDED: TIME: SPACE ABOVE THIS LINE FOR RECORDER'S USE The undersigned grantor(s) declare(s) Documentary transfer tax is $154.00 [ x ] computed on full value of property conveyed, or [ ] computed on full value less value of liens or encumbrances remaining at time of sale, [� ] Unincorporated Area City of unincorporated area of Oroville, FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Sandra J. Vogel, Trustee of the Peter J. Johnson Revocable Trust, dated June 13, 1994 hereby GRANT(S) to Adam Huey and Nicole Huey, husband and wife as joint tenants the following described real property in the City of unincorporated area of Oroville, County of Butte, State of California: SEE EXHIBIT "A" ATTACHED HERETO AND MADE A PART HEREOF DATED: September 26, 2006 STATE OF 4AW-Itii COUNTY OFaur�i� ON Otk oe� a"� , �oDCP before me, personally appeared J. y 04c-` (name of signer, to me known to be the person (or persons) described in and who executed the foregoing instrument and acknowledged that he/she/they executed the same as his/her/their free act and deed. Witness my hand and official seal. ,,,,,ERINW M, TAYAMEN Signature (I) 5 2009 My commission expires: ,F -. - .. ;MMIM ss MAIL TAX STATEMENTS AS DIRECTED ABOVE FD -213 (Rev 7/96) GRANT DEED (grant)(06-06) M 1�icrow No.: 06 -108398 -TG Locate No.: CAFNT0958-0958-0001-0000108398 Title No.: 06 -108398 -BEE EXHIBIT "A" THE LAND REFERRED TO HEREIN BELOW IS SITUATED IN THE UNINCORPORATED AREA, COUNTY OF BUTTE, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS: Parcel I: A portion of Lot 75, as shown on that certain Map entitled, "Official Map of Oroville-Wyandotte Fruit Lands Unit No. 3", which Map was filed in the Office of the Recorder of the County of Butte, State of California, October 10, 1927 in Book 11 of Maps, at Page(s) 19 and 20 and being more particularly described as follows: Beginning at the most Northerly comer of said Lot 75, said comer being also in the centerline of Apica Avenue, as shown on said Map; thence South 00 55' West along the centerline of said Apica Avenue, being the East line of said Lot 75, a distance of 278.06 feet; thence leaving the centerline of said Apica Avenue, South 540 45' West, a distance of 681.23 feet to the true point of beginning of the land herein described; thence from said true point of beginning, continuing South 540 45' West, 135.0 feet to a point in the Northeasterly line of that certain Parcel of land described in Deed from Harry J. Nott, et ux to Loren W. Quigley, et ux dated April 11, 1956 and recorded April 16, 1956 in Book 824 of Butte County Official Records, at Page 199; thence along said Northeasterly line, North 460 12' West a distance of 344.26 feet to a point in the centerline of the Oroville-Wyandotte Irrigation District ditch right of way, as shown on said Map; thence along said right of way and along the Northwesterly boundary line of said Lot 75, the following courses and distances: North 790 13' East 38.08 feet; thence North 690 36' East 30.00 feet, North 430 56' East 75.0 feet, more or less to a point which bears North 460 12' West from the true point of beginning; thence South 460 12' East 359.77 feet, more -or less to the true point of beginning. Parcel II: A right of way for road purposes 20 feet in width lying 10 feet on each side of the following described centerline: Beginning at the most Northerly comer of Lot 75, as shown on that certain Map entitled, "Official Map of Oroville- Wyandotte Fruit Lands Unit No. 3", which Map was filed in the Office of the Recorder of the County of Butte, State of California, October 10, 1927 in Book 11 of Maps, at Page(s) 19 and 20, said comer being also in the centerline of Apica Avenue, as shown on said Map; thence South 00 55' West, along the centerline of said Apica Avenue, being the East line of said Lot 75, a distance of 278.06 feet to the true point of beginning of the line to be described; thence from said true point of beginning, leaving said centerline, South 540 45' West a distance of 816.23 feet to a point in the Northeasterly line of the certain Parcel of land described in Deed from Harry J. Nott, et ux to Loren Q. Quigley, et ux dated April 11, 1956 and recorded April 16; 1956 in Book 824 of Butte County Official Records, Page 199; and the end of said line. Excepting therefrom that portion lying within Parcel I above described. AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 COPY of Document Recorded 9 -Oct -2006 2006-0052852 Has not been compared with original BUTTE COUNTY COUNTY RECORDER AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: Date kc� -"A-, - O (o State of California County of �1 7-1:5 On LO - 1 - C (o before PROPERTY OWNERS: Ayviw N Nicole- &Lev . L ��H . N0 i r_ - t'L�_ 0 t -t C_ personally appeared— A�cOkm lD . t- u\EN ;iN,,9 iUN O_EX -e_ `1 "V 1 personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s) or the entity upon behalf of which thp(s) ed, ex cuted lu ment. WITNESS i . t l _2S�A_ - Signature Seal: C. Costa Commission #15174790 U Notary Public -California Butte County A.P. 4 0 9 My Comm. Exp. Oct. 30, 2008 f Escrow No.: 06 -108398 -TG Locate No.: CAFNT0958-0958-0001-0000108398 Title No.: 06 -108398 -BEE EXHIBIT "A" THE LAND REFERRED TO HEREIN BELOW IS SITUATED IN THE UNINCORPORATED AREA, COUNTY OF BUTTE, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS: Parcel I: A portion of Lot 75, as shown on that certain Map entitled, "Official Map of Oroville-Wyandotte Fruit Lands Unit No. 3", which Map was filed in the Office of the Recorder of the County of Butte, State of California, October 10, 1927 in Book it of Maps, at Page(s) 19 and 20 and being more particularly described as follows: Beginning at the most Northerly comer of said Lot 75, said comer being also in the centerline of Apica Avenue, as shown on said Map; thence South 00 55' West along the centerline of said Apica Avenue, being the East line of said Lot 75, a distance of 278.06 feet; thence leaving the centerline of said Apica Avenue, South 540 45' West, a distance of 681.23 feet to the true point of beginning of the land herein described; thence from said true point of beginning, continuing South 540 45' West, 135.0 feet to a point in the Northeasterly line of that certain Parcel of land described in Deed from Harry J. Nott, et ux to Loren W. Quigley, et ux dated April 11, 1956 and recorded April 16, 1956 in Book 824 of Butte County Official Records, at Page 199; thence along said Northeasterly line, North 460 12' West a distance of 344.26 feet to a point in the centerline of the Oroville-Wyandotte Irrigation District ditch right of way; as shown on said Map; thence along said right of way and along the Northwesterly boundary line of said Lot 75, the following courses and distances: North 790 13' East 38.08 feet; thence North 690 36' East 30.00 feet; North 430 56' East 75.0 feet, more or less to a point which bears North 460 12' West from the true point of beginning; thence South 460 12' East 359.77 feet, more or less to the true point of beginning. Parcel II: A right of way for road purposes 20 feet in width lying 10 feet on each side of the following described centerline: Beginning at the most Northerly comer of Lot 75, as shown on that certain Map entitled, "Official Map of Oroville- Wyandotte Fruit Lands Unit No. 3", which Map was filed in the Office of the Recorder of the County of Butte, State of California, October 10, 1927 in Book it of Maps, at Page(s) 19 and 20, said corner being also in the centerline of Apica Avenue, as shown on said Map; thence South 00 55' West, along the centerline of said Apica Avenue, being the East line of said Lot 75, a distance of 278.06 feet to the true point of beginning of the line to be described; thence from said true point of beginning, leaving said centerline, South 540 45' West a distance of 816.23 feet to a point in the Northeasterly line of the certain Parcel of land described in Deed from Harry 1. Nott, et ux to Loren Q. Quigley, et ux dated April 11, 1956 and recorded April 16, 1956 in Book 824 of Butte County Official Records, Page 199; and the end of said line. Excepting therefrom that portion lying within Parcel I above described. °&\ Department of Public Works C o u n t y o f B u t t e O 0 LAND DEVELOPMENT DIVISION I� J. Michael Crump, e Storm Water Management Program l Director 7CountyCenterDrive Oroville. CA 95965 10 QC WORDS (530) 538-7266 (FAX) 538-7171 National 'Pollutant Discharge Elim.ination System (NPDES) Phase 11 Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgement [LESS THAN 1 ACRE1 Project Description: Project Location and/or Parcel Number: l9loq^ Y 70 — 03 By signing below, I, the project owner/owner's agent, certify that this project, WILL NOT DISTURB I acre or more of land and that L therefore, do not need to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. Phased projects that contain multiple site build -outs of less than one acre but when combined with subsequent phases total more than one acre of disturbed soil will require a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. I am aware that submitting false and/or inaccurate information or failure to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board for a project that disturbs one acre or more of land may result in revocation of grading and/or other permits or other sanctions provided by law. Sign ed: Title: 01,,re r Date: 7-l3 OCn Less than 1 Acre NPDES & SWPPP Compliance Certification -�nces Butte Cour2ty-Depaftment of-.Develop.r72erlt Ser o�`'TrFo 7 County Center Drive Oroville, CA 95965 fes" o •__ o (530) 538-7601 Telephone (530) 538-7785 Facsimile coUN�y BUILDING PERMIT APPLICATION WITHOUT REQUIRED CLEARANCES I request and authorize the Building Division to process this building permit application through the plans examination process WITHOUT first obtaining all necessary, related permits and clearances from other regulatory entities, including but not limited to, Planning, Environmental Health, Land Development, County Fire, and Agriculture. I hereby acknowledge: I need to submit applications for septic and/or well to Butte County Environmental Health immediately. v I am required to bring the approved Environmental Health site plan and approved sanitation clearance to the Building Division as soon as clearance is obtained a I am responsible for notifying Development Services, in writing, to stop processing of the application and to arrange for'disposition of plans. The Building Division will process the application through the plans examination process, as submitted, without input from other regulatory entities that could prohibit issuance of the building permit or require submission of amended building plans to the Building Division. Once the plans examination process begins, there will be no refund of plans examination fees. Any changes requiring submission of amended plans to the Building Division will incur additional fees. Within one year from the date of application for a building permit, all other required permits and clearances from other.. entities must be obtained for the permit to be issued. Failure to obtain these permits/clearances will void the application. Typically other required permits/clearances include, but are not limited to, verification the parcel was legally created, adherence to. all mitigations and conditions imposed on the parcel at time of creation, as well as zoning requirements, legal access, and applicable set -backs and environmental issues (fire, agriculture buffer zones, and habitat/species). Please print: Applicant Name: APN: Building site address: a_ C - Permit No.: I have read, understood and accept the terms and conditions as expressed herein as indicated by my submission of the above -referenced building permit application and my signature below: DATE SIGNATURE OF APPLICANT 069-470-037 06-1695 HUEY, ADAM. T� ^-r. --: : "%v.... .q NOTES �,�.. M—APICAyCT; OROVILLE Cont: JOHN WHEELER CONST l: NSVGAR/DECKS(OPEN & COV): RESIDENTIAL APN: Permit No. Owner. Site Address: Contractor. Type of Permit: / SPECIAL CONDITIONS CHECKED BY SRA FLOOD CERTIFICATE EQUIRED FIRE SPRINKLERS REQUIRED SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUBSTANDARD HOUSING LETTER. ENCROACHMENT PERMIT REINSPECTION FEE PAID ENV HLTH CLEARANCE DATE JOB FINALED: SIGNATURE: AREA • =OK 0 = Not OK MANUFACTURED HOMES I MISCELLANEOUS - DATE LJ PERMANENT FOUNDATION LJ SOFT -SET 1 ZoningSetbacks-Easements 2 Soils; Special MH Support Sketch 3 Sewer; Loctn-Test; Fall/C/O-Concrete 4 Wtr; Loctn-Test-Easeinent Needed -Regulator 5 Elec Loctn-Dimes-Gmd 'Amp -Concrete 6 Yard Gas; Loctn-Test-Wrap Nat ❑ or LP[::] Inch Sz Ft Lngth 7 Blckng; SzSpadng-Marriage Line 8 Gas; MH Test-Demand-Valve-Dnnctr 9 Elec MH Cntnty Test-Crossovers-Breakers-Clmcs 10 Drain; MH Test -Fall -Flex Cnnctr 11 Wtr & Sewer Connected -C/O to Grade 12 Gas and Electricity Tagged 13 Tie Downs ❑ Foundation ❑ 14 Exits 15 Cert of Occupancy 16 HUD LabeUlnsignia Numbers Serial Numbers o,,a o1s' o'.o v1s' DECKS'COVERWCARP0RTS'GARAGES 1 ZoningSetbacks-Easements 2 Ftgs; SailsSz=DpthSpacing-CnnctrsSteel 3 Decks, Girders/Joists-0cking-Brcing Stairs-GuardlHandrails 4 Wood Awn; Posts-Beams-Rftrs-CnnctrsShthg. Frmg-Brcng 5 Alum Awn; Columns-DnnctnsSplice-Decal-Encisrs 6 Carports; Wndws-Doors 7 Electric 8 Frmg; Sills-AnchrsStuds-Rftrs Trusses 9 Siding; Nailing -Veneer -Stucco -Lath 10 Roof; Shthg-Roofing 11 Ext; Steps -Doors -Landings 12 Braced Wall pnls 1 Setbacks -Easements T_ 2 Soils; 'CompactionStructure Stability 3 Pool Structure; Steel-Cnnctns-Thickness Dead Men -Lining 4 Elec Rcptcls/Lting; Distance-GFI 5 Elec Pool Lting; 15 volts-GFI 6 EIec.Encisrs; Conduit Entries -Terminals -Listed - 7 Elec Bonding; Metal w/5'-Crcitng Egp-Htr 8 Elec Gmdng; Eqp w/5' Crcltng Eqp-Pool Ightg Boxe-Enalsrs-pnlboardsansultn to Main Conduit 9 Health Dept Apprvl 10 'Pimb; Cir Test-Wtr Supply Test 11 Lt Niche ' 12 Enclsr, Fencing -Alarms 13 Bonding, Diving board or Slide d'1 0`a' Drawing RESIDENTIAL (Single & Duplex) DATE JUNDERFLOOR DATE PLUMBING 1 zoningsetbacks-l=asements-FloodSlope 2 Ftg Main; Sails-Elec Gmd Ftg Dpth 3 Ftg Garage; SoilSSteel-Elec Gmd Ftg Dpth 4 Ftg Parches/Decks; Soils -Steel Ftg Dpth 5 Stemwalls'Main; Steel-Biockouts Wrapped 6 Stemwalls Garage; Steel-Blockouts Wrapped 6a Hold Downs and Special Anchrs 7 Slab, Steel Wrapped 8 Piers-Frpic Ftg-Steel 9 DWV; Fall -Fitting -Test -2 -way CIO -Sewer Test 10 UF, Gas Pipe; Sz Anchrs-Sz Test 11 Wtr Pipe; Test Anchrs-RgitrService Test 12: Elec Undrgrnd 13 Plenums & Ducts; Clrnc-MaterialSupport4nsultn 14 GirdersSills-Anchr Bolts-Joists-Vnts-Cripples 15 Ace & Vntltn 16 Insulation DATE JFAAMING 17 Sills Proper Materials & Anchrs 18 Walls Studs -Nailing Spacing & Braces -Plates -Sound 19 Bearing Walls over Girders & fir Nailing 20 Draft Stop In Walls (rat proof) 21 Fire Stops; Furred CeilingsStairs-Chasers-Tubs 22 Headers & 3eaihs-Si &, Bearing 23 Hangers-Posf Caps-Anchrs-Cnnctns 24 Ceiling Joist-Rftr Ties-Purlin-Roof Brac-TrussShthg 25 Frplc Ties orType A Flue=Frpic Throat Clmc 26 Attic Acc; Sz &"Rfitz PitetnAraft Stop4ns Baffles 27 Bdrm Wndws or Exiting 15oorsSill Ht & Dimensions 28 Garage Fire Prtchi Framing -RC Channel 29 Prprty Line Firewall & Opngs' 30 Ext Doors -One X -Check Garage 3rd Story, 2 Exits 31 Stairs; Width-Hdrm-Rise-Run-Landing-Fire Prtctn 32 Plywd on Roof Ovrhng Attic Vnts-Rftr Outrgrs 33 Siding -Nailing Veneer 34 Stucco Lath Weep Screed-Fndtn Vnts-Undrflr Ace 35 Glazing Area -Glass PrtctnSkyLts-Plastic . 36 Shear Walls; Nailing -Bolts 37 Brace IntiExt Wall pnls 38 tnsuitn-Walls-Ceilings 39 Infiltration Walls-Wndws DATE JELECTRICAL 40 Fxtr & Trnsfrmr Clrnc-Ins Prtctn 41 Elec Rcptcls Spacing-Lts & Switches at Doors 42 Sz Boxes & No Of Cndctrs Stapled 43 Romex Installed Close to Edge of Studs & CJ 44 Eqp Grnd made up w/Mech Fstnrs 45 Gmdng Electrode Bond Gas & Wtr 46 2 Appinc Cires in Ktchn & Cndctr Sz GFI 47 Subfeed Wire Sz ya ❑ CU or DAL AC Wire Sz ya ❑ CU or DAL 48 Range Circ ya D CU or D AL Oven Circ ga D CU or DAL Insulated Neutral ❑Yes DNo 49 Service4User Cndctrs & Gmd Main Dscnnct 50 Eqp Clrncs pnls-Motors-Mech Eqp 51 Clothes Closet LtShwr Lt -Spa Lt 52 Smoke Detector 53 Wtr Htr; Vent Acc-Dmbstn Air Baffle 54 Wtr Pipe; Test & Anchr-Nail Prtctn 55 DWV; Test Fittings & Anchr. Nail Prfctn 56 Shwr Pan; Test, First fir -Tub Ace 57 Test Tub & Shwr, 2nd fir - Tub Ace 58 Gas Pipe; Sz & Anchrs 59 Fire Sprinkler; Test 60 Yard Gas.Piping o DATE IMECHAKICAL 61 AC Ducts Insults & Support " 62 Vent Fan, Exhaust abv Insultn 63 Condensate Drain & Ovrflw, Sz & Grade 64 Furnace -Vent Acc-Comb Air Rtrn/Vent 115 Outlet 65 Attic Ace & Pltfrin if Furnace in attic DATE jFiNAL 66 Ext Steps -Door & SideLt Prtctn-Landings 67 Smoke Detector 68 Furnace Vnts-Clmc-Comb, Air-Cnnctr In Garage; abv-flr-Ducts-Meth Prtctn 69 Bedroom Exiting 70 GFI & Bath Fxtrs & Tub AccSpa 71 GFI Are Fault 72 Elec Trim & Subpnl, Breaker Szs & Labels 73 Stairs, Guard/Handrails 74 Frpic or Stove, Clmc-Hearth 75 Elec Outlets at Wood Pnl, Int & Ext 76 Ktchn, Fxtr & Appinc; Gmd-Air-Gap-Cooking Clrnc 77 Elec Outlets & Rcptcls at Ktchn Counter 78 Garage Fire Door, Swing -Landing -Closure 79 AC Duct in Garage -Damper. 80 Wtr Htr, Vnts-Clmc-Com Air Cnnctr-PRV; abv fir Mech Prtctn; LPG Appince Undr House 3" drain 61 PImb; Elec & Mech Eqp Listed for Loctn 82 Elec Rcptcls in Garage (GFI) Romex Prtctn 83 Insultn-Foam-Looked in Attic 84 Guard Rails & Deck Cnstrctn-Post Caps 85 Fndn Vnts & Crawl Hole Door Dmge & Wood -Earth 86 Clmc Dmge Planters D Yes D No 87 Stucco Brown -Finish 88 AC Unit Dscnnct, Elec-PImb 89 Vnts abv Roof, PImb-Appinc-Frpic-Clmc to Opngs 90 Wtr Well, Dscnnct, Elec, PImb 91 Ext Elec Trim, GFI Rcptcl-Undrgrnd 92 Vntitn thru House 93 Glass Prtctn 94 Corrections from previous l6spctns 95 Gas Test -Meters Tagged, Gas-Elec 96 Wtr & Sewer Cnnctd-C/O to grade -HD Apprvl 97 Energy Cmpinc Cert -Other Certs 98 Address Posted 99 Fire Sprinkler + a` 'M N Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile ADMINISTRATION * BUILDING * PLANNING August 29, 2006 Adam Huey 25 Hunter Drive Oroville, Ca. 95966 Assessor Parcel Number: 069-470-037 Building Permit Number: 06-1695 Thank you for submitting the plans for your building project. The plans have been reviewed and comments are listed below. Please respond in writing to each item by letter or by completing and returning the enclosed Plan Review Response Form. Your complete and clear response will expedite the re -check and approval of this project. COMMENTS: 1. Please design the cripple walls for lateral force resistance and show requirements on the plans. The lateral analysis provided does not appear to account for lateral forces acting on the cripple walls. Please account for wind forces acting on the cripple walls and include the weight of the floor diaphragm plus the perpendicular walls in the seismic calculations. 2. Provide a collector or drag truss to transfer lateral forces to the shear walls along wall line 3. 3. Please specify nailing required from the roof diaphragm sheathing to all drag trusses. 4. Provide verification from the truss manufacturer that all trusses intended to transfer drag loads have been designed accordingly. 5. The roof plan specifies two "Simpson DSC" connectors near the front entry. Please clarify which trusses the connectors will be connected to and provide verification from the truss manufacturer that the trusses have been designed to accommodate the drag loads. Also, please specify the entire model number of the connectors (i.e. will they be Simpson DSC4R- SDS3?). 6. Note 6 on truss E2 is a warning indicating that the "required bearing size at joint one is greater than the input bearing size". Please clarify. 7. Provide documentation from the engineer stating that he has reviewed the truss package and that the trusses conform to his design of the structure. 8. Provide MST60 straps at top plate splices along wall line 3 as specified in the structural calculations. 9. Provide calculations for the retaining wall footing supporting the raised floor and the garage slab. Section B -B on sheet 5 references detail 5/4, but this detail shows a standard height footing. If you wish to discuss any of these requirements, please call (530) 538-7541 between the hours of 1:00 p.m. and 4:00 p.m., Monday through Friday. Please refer to your Data Sheet for remaining non -plan check items. (You received this form when you applied for your permit.) The counter staff will answer any questions concerning the Data Sheet. Jim Peterson Plans Examiner cc: Ausmus Engineering Philo Hunt, P.E. Plan Check Engineer r' USMUS ALAenur��esrvr, Civil En ineering — Architectural Drafting — Structural Drafting PO Box 5115 Chico, CA 95927 (530) 521-2648 eda@ausmusengineering.com PLAN REVIEW RESPONSE August 29, 2006 September 9, 2006 To: Philo Hunt Butte County Building Department . 7 County Center Drive Oroville, CA 95965 From: Eric D. Ausmus, P.E. Ausmus Engineering PO Box 5115 Chico, CA 95927 Subject: Huey Residence Assessor Parcel Number: 069-470-037 Building Permit Number: 06-1695 Recnnnce to Ctmetnral f nmmontc- Comment1 Location on Plans 1,1 Engineering calculations were revised to include Revised engineering calfs the lateral effects to the pony walls. A new detail (added lower level calfs. Also • has been added to foundation plan added Detail P/2 2 No drag truss will be required on walline 3. There None �. are no shearwalls.in the-main-portion-of-the-hom along walline 3. Shear will be evenly distributed to the cathedral trusses at the main port�of home through the roof sheathing. 3 ry: Truss calfs were revised to include drag loads. Roof plan/Truss calfs t. Nailing was stated on Roof Plan. 4 Truss calfs were revised and submitted along Revised Truss Calcs. See r • with this submittal. notes section for each revised truss on calculation page. a �5 DSC at the intersection of walline 2 and C was Roof Plan walline C deleted as this was placed at the midpoint of truss &}v " HGE instead of at the end. Drag loads were ! r added to trusses. DSC model labeled. , Y'-6, 2X4 wall was insufficient for bearing. This wall Revised truss calfs and 2x6 at garage was increased to 2x6. Thank you for wall at garage. See floor plan catching that ;, .,7A. Truss concurrence letter attached stating See appendix of engr calfs I applicable revisions. Page 1 of 2 CAAusmus Engineering\2006 Projects\Huey\Plan Check Response 8-30-06.doc USMUS Civil Eneineering — Architectural Drafting — Structural Drafting_ PO Box 5115 Chico, CA 95927 (530) 521-2648 eda@ausmusengineering.com 8 Top plate splice schedule has been updated. Thank you. Floor plan 9"' New calcs provided. Thank you. See appendix of engr calcs Thank you for y ur review and let me know if you have any more comments or concerns i Eric D. Ausmus, P.E. Ausmus Engineering (530) 521-2648 Page 2 of 2 CAAusmus Engineering\2006 Projects\Huey\Plan Check Response 8-30-06.doc Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile ADMINISTRATION * BUILDING * PLANNING August 29, 2006 Adam Huey 25 Hunter Drive Oroville, Ca. 95966 Assessor Parcel Number: 069-470-037 Building Permit Number: 06-1695 Thank you for submitting the plans for your building project. The plans have been reviewed and comments are listed below. Please respond in writing to each item by letter or by completing and returning the enclosed Plan Review Response Form. Your complete and clear response will expedite the re -check and approval of this project. COMMENTS: 1. Please design the cripple walls for lateral force resistance and show requirements on the plans. The lateral analysis provided does not appear to account for lateral forces acting on the cripple walls. Please account for wind forces acting on the cripple walls and include the weight of the floor diaphragm plus the perpendicular walls in the seismic calculations. 2. Provide a collector or drag truss to transfer lateral forces to the shear walls along wall line 3. 3. Please specify nailing required from the roof diaphragm sheathing to all drag trusses. 4. Provide verification from the truss manufacturer that all trusses intended to transfer drag loads have been designed accordingly. 5. The roof plan specifies two "Simpson DSC" connectors near the front entry. Please clarify which trusses the connectors will be connected to and provide verification from the truss manufacturer that the trusses have been designed to accommodate the drag loads. Also, please specify the entire model number of the connectors (i.e. will they be Simpson DSC4R- SDS3?). 6. Note 6 on truss E2 is a warning indicating that the "required bearing size at joint one is greater than the input bearing size". Please clarify. 7. Provide documentation from the engineer stating that he has reviewed the truss package and that the trusses conform to his design of the structure. 8. Provide MST60 straps at top plate splices along wall line 3 as specified in the structural calculations. 9. Provide calculations for the retaining wall footing supporting the raised floor and the garage slab. Section B -B on sheet 5 references detail 5/4, but this detail shows a standard height footing. If you wish to discuss any of these requirements, please call (530) 538-7541 between the hours of 1:00 p.m. and 4:00 p.m., Monday through Friday. Please refer to your Data Sheet for remaining non -plan check items. (You received this form when you applied for your permit.) The counter staff will answer any questions concerning the Data Sheet. Jim Peterson Plans Examiner cc: Ausmus Engineering Philo Hunt, P.E. Plan Check Engineer TABLE OF CONTENTS TOC ---------------------------------- ---------------------------- --------------------- Project Title.......... ADAM & NICOLE HUEY Date..12/04/07 18:14:49 Project Address........ LOT #37 APICA COURT ******* --------------------- OROVILLE CA. 95966 *v7.10* Documentation Author... BARRY RUBANOFF ******* Building Permit # Barry Rubanoff P.O. Box 1123 Plan Check / Date Berry Creek, CA 95916 530-589-4102 Field Check/ Date Climate Zone........... 11 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 Program -TOC I User#-MP2246 User -Barry Rubanoff Run-HUEY - ------------------------------,------------------------------------------------ TABLE OF CONTENTS ----------------- Report Page FORM CF -1R ................ 1 FORM MF -1R ............. 7 HVAC SIZING ............:.. 11 j�✓i5� T 2 � �yP a 6 - >&9.� BUTTE COUNTY BUILDING DIVISION APPROVED /215�07 CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 1 Project Title.......... ADAM & NICOLE HUEY Date 12/04/07 18:14:49 Project Address........ LOT #37 APICA COURT ******* --------------------- OROVILLE CA. 95966 *v7.10* Documentation Author... BARRY RUBANOFF ******* Building Permit # Barry Rubanoff P.O. Box 1123 Plan Check / Date Berry Creek, CA 95916 530-589-4102 Field Check/ Date Climate Zone........... 11 --------------------- Compliance Method...... MICROPAS7 v7.10.for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 Program -FORM CF -IR User#-MP2246 User -Barry Rubanoff Run-HUEY ------------------------------------------------------------------------------- _________________________________________________________________ MICROPAS7 ENERGY USE SUMMARY = ----------------------------- _ Energy Use Standard Proposed Compliance = (kTDV/sf-yr) Design Design Margin = Space Heating.......... 33.84 29.82 4.02 = Space Cooling.......... 26.17 25.94 0.23 Water Heating.......... 16.13 18..27 -2.14 = Total 76.14 74.03 2.11 = *** Building complies with Computer Performance *** HERS Verification Required for Compliance GENERAL INFORMATION ------------------- HERS Verification.......... Required Conditioned Floor Area..... 2989 sf Building Type .............. Single Family Detached Construction Type ......... New Fuel Type .. Propane Building Front Orientation. Front Facing 150 deg (SE) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Raised 2 27520 0 sf Floor cf 13.9 % of floor. area 0.37 Btu/hr-sf-F 0.34 9.2 ft CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2 ------------------------------------------------------------------------ - Project Title.......... ADAM & NICOLE HUEY Date..12/04/07 18:14:49 --------------------------------------------- MICROPAS7 x7.10 File-HUEY Wth-CTZ11S05 Program -FORM CF -1R User##-MP2246 User -Barry Rubanoff Run-HUEY -------------------------------------------=----------------------------------- BUILDING ZONE INFORMATION Orientation ZONE1 1 Wind Front (SE) 2 Wind Front (SE) 3 Wind Front (SE) 4 Wind Front (SE) 5 Wind Front (SE) FENESTRATION SURFACES Exterior Area U- Act Shade (sf) factor SHGC Azm Tilt Type Location/Comments ----- ----- ----- -=- ---- -------- ------------------------ 24.0 0.350 0.330 150 90 Standard F1/Vinyl/Wood Oper Low E 6.0 0.400 0.350 150 90 Standard F2/Vinyl/Wood Fixed Low 6.0 0.400 0.350 150 90 Standard F3/Vinyl/Wood Fixed Low 6.0 0.4.00 0.350 150 90 Standard F4/Vinyl/Wood Fixed Low 30.0 0.350 0.330 150 90 Standard F5/Vinyl/Wood Oper Low E Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap ---------- -------------- ZONE1 ----- ------ ----- ----- ----- -------- ------------ Residence 1648 14832 0.55 2.2 Yes Setback 2.0 Standard No ZONE2 Residence 1341 12688 0.45 1.8 Yes Setback 2.0 Standard No OPAQUE SURFACES --------------- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments ------------ ZONE1 ----= ---- ----- ----- ----- --- ---- --- ----------------------- 1 Wall Wood 259 0.074 19 0 150 90 Yes IV.9 A5 4 Wall Wood 406 0.074 19 0 240 90 Yes IV.9 A5 7 Wall Wood 303 0.074 19 0 330 90 Yes IV.9 A5 9 Wall Wood 77 0.074 19 0 60 90 Yes IV.9 A5 12 Roof Wood 1648 0.025 38 0 n/a 0 Yes IV.1 A18 15 Floor Wood 1648 0.037 19 0 n/a 0 Yes IV.20 A4 17 Door Other 20 0.500 0 0 150 90 Yes IV.5 A4 ENTRY DOOR ZONE2 2 Wall Wood 62 0.074 19 0 150 90 Yes IV.9 A5 3 Wall Wood 306 0.074 19 0 150 90 No IV.9 A5 5 Wall Wood 72 0.074 19 0 240 90 Yes IV.9 A5 6 Wall Wood 34 0.074 19 0 240 90 No IV.9 A5 8 Wall Wood 267 0.074 19 0 330 90 Yes IV.9 A5 10 Wall Wood 305 0.074 19 0 60 90 Yes IV A A5 11 Wall Wood 79 0.074 19 0 60 90 No. IV A A5 13 Roof Wood 991 0.025 38 0 n/a 0 Yes IV.1 A18 14 Roof Wood 350 0.025 38 0 150 19 Yes IV.1 A18 16 Floor Wood 1341 0.037 19 0 n/a 0 Yes IV.20 A4 18 Door Other 18 0.500 0 0 60 90 No IV.5 A4 TO GARAGE Orientation ZONE1 1 Wind Front (SE) 2 Wind Front (SE) 3 Wind Front (SE) 4 Wind Front (SE) 5 Wind Front (SE) FENESTRATION SURFACES Exterior Area U- Act Shade (sf) factor SHGC Azm Tilt Type Location/Comments ----- ----- ----- -=- ---- -------- ------------------------ 24.0 0.350 0.330 150 90 Standard F1/Vinyl/Wood Oper Low E 6.0 0.400 0.350 150 90 Standard F2/Vinyl/Wood Fixed Low 6.0 0.400 0.350 150 90 Standard F3/Vinyl/Wood Fixed Low 6.0 0.4.00 0.350 150 90 Standard F4/Vinyl/Wood Fixed Low 30.0 0.350 0.330 150 90 Standard F5/Vinyl/Wood Oper Low E CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 3 Project Title.......... ADAM & NICOLE HUEY Date..12/04/07 18:14.49 MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 Program -FORM CF -1R User#-MP2246 User -Barry Rubanoff Run-HUEY ----------------------------------------=-------------------------------------- FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----------- ----- --- ------------ ------------------------ 7 Wind Left (SW) 6.0 0.350 0.330 240 90 Standard L1/Vinyl/Wood Oper Low E 8 Wind Left (SW) 16.0 0.400 0.350 240 90 Standard L2/Vinyl/Wood Fixed Low 9 Wind Left (SW) 8.0 0.400 0.350 240 90 Standard L3/Vinyl/Wood Fixed Low 10 Wind Left (SW) 8.0 0.460 0.350 240 90 Standard L4/Vinyl/Wood Fixed Low 11 Wind Left (SW) 15.0 0.350 0.330 240 90 Standard L5/Vinyl/Wood Oper Low E 12 Wind Back (NW) 15.0 0.350 0.330 330 90 Standard B1/Vinyl/Wood Oper Low E 13 Wind Back (NW) 15.0-0.350 0.330 330 90 Standard B2/Vinyl/Wood Oper Low E 14 Wind Back (NW) 54.0 0.350 0.330 330 90 Standard B3/Vinyl/Wood Oper Low E 15 Wind Back (NW) 15.0 0.350 0.330 330 90 Standard B4/Vinyl/Wood Oper Low E 16 Door Back (NW) 46.0 0.400 0.350 330 90 Standard B5/Vinyl/Patio Door Low 20 Door Right (NE) 40.0 0.400 0.350 60 90 Standard R1/Vinyl/Patio Door Low ZONE2 6 Wind Front (SE) 10.0 0.350 0.330 150 90 Standard F6/Vinyl/Wood Oper Low E 17 Wind Back (NW) 15.0 0.350 0.330 330 90 Standard B6/Vinyl/Wood Oper Low E 18 Wind Back (NW) 15.0 0.350 0.330 330 90 Standard B7/Vinyl/Wood Oper Low E 19 Wind Back (NW) 20.0 0.350 0.330 330 90 Standard B8/Vinyl/Wood Oper Low E 21 Wind Right (NE) 6.0 0.350 0.330 60 90 Standard R2/Vinyl/Wood Oper Low E 22 Wind Right (NE) 20.0 0.350 0.330 60 90 Standard R3/Vinyl/Wood Oper Low E 23 Wind Right (NE) 20.0 0.350 0.330 60 90 Standard R4/Vinyl/Wood Oper Low E OVERHANGS ---Window--- ------------ Overhang ------------ Area. Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- ----- ----- ------ ----- ------------------------ ZONE1 2 Window 6.0 1.0 6.0 8.0 1.50 n/a n/a 3 Window 6.0 6.0 1.0 8.0 0.50 n/a n/a 4 Window 6.0 1.0 6.0 8.0 1.50 n/a n/a 7 Window 6.0 2.0 3.0 1.5 1.25 n/a n/a 8 Window 16.0 4.0 4.0 1.5 1.25 n/a n/a 9 Window 8.0 4.0 2.0 1.5 1.25 n/a n/a 10 Window 8.0 4.0 2.0 1.5 1.25 n/a n/a 11 Window 15.0 3.0 5.0 12.0 1.25 n/a n/a 14 Window 54.0 9.0 6.0 8.5 0.25 n/a n/a 15 Window 15.0 3.0 5.0 10.0 1.25 n/a n/a 16 Door 46.0 6.0 7.67 10.0 0.25 n/a n/a 20 Door 40.0 6.0 6.67 12.0 1.25 n/a n/a ZONE2 6 Window 10.0 2.5 4.0 8.0 1.0 n/a n/a 17 Window 15.0. 3.0 5.0 10.0,.1..25 n/a n/a 18 Window 15.0 3.0 5.0 1.5 1.25 n/a n/a 21 Window 6.0 2.0 3.0 1.5 1.25 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 4 ----------------------------------------------------------------- Project Title.......... ADAM & NICOLE HUEY Date..12/04/07 18:14:49 I MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 Program -FORM CF -1R I User#-MP2246 User -Barry Rubanoff Run-HUEY ------------------------------------------------------------------------------- OVERHANGS ---Window--- ------------Overhang------------ Area Left Right Surface (sf) Width Height Depth Height Extension Extension ----------- ----- ----- ------ ----- ------ --------- --------- 22 Window 20.0 4.0 5.0 1.5 1.25 n/a n/a 23 Window 20.0 4.0 5.0 1.5 1.25 n/a n/a System Type ------------ ZONE1 Furnace ACSplit ZONE2 Furnace ACSplit HVAC SYSTEMS ------------ Verif ied Number Verified Verified Verified Verified Maximum of Minimum Refrig Charge Adequate Fan Watt Cooling Systems Efficiency EER or TXV Airflow Draw Capacity ------- ----------- ----- ------------- -------- -------- -------- 1 1 1 1 System Type ------------- ZONE1 Furnace ACSplit ZONE2 Furnace ACSplit ------------- Total 0.900 AFUE n/a n/a n/a n/a n/a 16.00 SEER 12.0 Yes No No No 0.900 AFUE n/a n/a n/a n/a n/a 16.00 SEER 12.0 Yes No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling Load Load Capacity Capacity (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) ---------------------------------------- 27955 n/a 21012 n/a 48967 n/a 21713 n/a 14598 36311 n/a 26203 n/a 17617 43820 Sizing Location............ OROVILLE RS Winter Outside Design...... 25 F Winter Inside Design....... 70 F Summer Outside Design...... 102 F Summer Inside Design....... 75 F Summer Range ............... 37 F n/a n/a n/a n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5 ---------------------------------------------------------------------- Project Title.......... ADAM & NICOLE HUEY Date..12/04/07 18.14:49 ! MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 'Program -FORM CF -1R User#-MP2246 User -Barry Rubanoff Run-HUEY ------------------------------------------------------------------------------- System Type ------------- ZONE1 ' Furnace ACSplit ZONE2 Furnace ACSplit DUCT SYSTEMS ------------ Verified Verified Verified Duct Duct Duct Surface Buried Location R -value Leakage Area Ducts ----------- ------- ------- ------=- --------- Attic Attic Attic Attic R-8 No R-8 No R-8 No R-8 No No No No No No No No No WATER HEATING SYSTEMS --------------------- Number Heater in Energy Tank Type Type Distribution Type System Factor ---------------- -------- ------------------- ------ -------- 1 Storage Gas . Standard 2 0.63 Tank External Size Insulation (gal) R -value ------ 40 ---------- R- n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates a HERS verified Refrigerant Charge test or a HERS verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. This building incorporates a non-standard Water Heating System. HERS REQUIRED VERIFICATION -------------------------- *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** ***.the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF -4R installation certificate. *** This building incorporates a HERS verified Refrigerant Charge test or a HERS.verified Thermostatic Expansion Valve (TXV). If a cooling system is not installed, then HERS verification is not necessary. This building incorporates HERS verified EER. CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 6 7 ----- Project Title.......... ADAM.& NICOLE HUEY Date..12/04/07 18:14:49 1 MICROPAS7 v7.10 File-HUEY. Wth-CTZ11S05 Program -FORM CF -1R I User#-MP2246 User -Barry Rubanoff Run-HUEY ------------------------------------------------------------------------------- REMARKS COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER.or OWNER DOCUMENTATION AUTHOR Name.... ADAM & NICOLE HUEY Name.... Company. OWNER/BUILER Company. Address. Address. Phone... Phone... License. Signed.. J S Signed.. ( e) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) BARRY RUBANOFF Barry Rubanoff P.O. Box 1123 Berry Creek, CA 95916 530-589-4102 (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 7 -------------------------------------------------------------------- Project Title.......... ADAM & NICOLE HUEY Date..12/04/07 18.14:49 Project Address........ LOT #37 APICA COURT ******* --------------------- OROVILLE CA. 95966 *v7.10* Documentation Author... BARRY RUBANOFF ******* Barry Rubanoff P.O. Box 1123 Berry Creek, CA 95916 530-589-4102 Building Permit # Plan Check / Date Field Check/ Date Climate Zone........... 11 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 Program -FORM MF -1R User#-MP2246 User -Barry Rubanoff Run-HUEY ------------------------------------------------------------------------------- Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all.parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R719 insulation in wood framed ceiling or equivalent U -factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R -Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor 150(e): Installation of Fireplaces, Decorative Gas Appliances. and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire .opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.30, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF -6R form 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 4Z 2. Fenestration products (except field -fabricated) have MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 8 ----------------------------------------------------------------- Project Title.......... ADAM & NICOLE HUEY Date..12/04/07 18:14:49 I MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 Program -FORM MF -1R User#-MP2246 User -Barry Rubanoff Run-HUEY ------------------------------------------------------------------------------- label with certified U -factor, certified Solar Heat Gain. Coefficient (SHGC), and infiltration certification _1AZ 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with.ASHRAE, SMACNA or ACOA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R -value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water % r pipes shall be insulated to Table 150B 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A -=: 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely in conditioned space_ 7. Solar water -heating systems/collectors are certified by Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, AUkNDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 9 Project Title.......... ADAM & NICOLE HUEY Date..12/04/07 18:14.49 MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 Program -FORM MF -1R I i User#-MP2246 User -Barry Rubanoff Run-HUEY ------------------------------------------------------------------------------- UL 181A,, or UL 181B or aerosol sealant that.meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support platforms for air handlers, and plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause%_ reductions in the cross-sectional area of the ducts l/ 3. Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers' 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. !!�� 3. Pool system has directional inlets and a circulation pump time switch 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150 -C, -and do not contain a medium screw base -socket (E24/E26). Ballast for lamps 13 watts or greater are electronic MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 10 Project Title.......... ADAM & NICOLE HUEY Date..12/04/07 18:14:49 MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 Program -FORM MF -1R I I User#-MP2246 User -Barry Rubanoff Run-HUEY -------------------------------------------------------------1/ ------ and have an output frequency no less than 2.0 kHz 150(k)1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, luminaire has factory installed HID ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5:. Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680.1ocations) OR are controlled by occupant sensors with integral photo control certified to comply with Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shall have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) MVAC SIZING HVAC Page 11 ------------------------------- Project Title.......... ADAM & NICOLE HUEY Date..12 04 07 18:14:49 Project Address........ LOT #37 APICA COURT ******* --------------------- OROVILLE CA. 95966 *v7.10* Documentation Author... BARRY RUBANOFF ******* Building Permit # Barry Rubanoff P.O. Box 1123 Plan Check / Date Berry Creek, CA 95916 530-589-4102 Field Check/ Date Climate Zone........... 11 --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. ---------------- I MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 Program -HVAC SIZING User#-MP2246 User -Barry Rubanoff Run-HUEY ------------------------------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 2989 sf Volume .................... 27520 cf Front Orientation.......... Front Facing 150 deg (SE) Sizing Location............ OROVILLE RS Latitude ................... 39.5 degrees Winter Outside Design...... 25 F Winter Inside Design....... 70 F Summer Outside Design...... 102 F Summer Inside Design....... 75 F Summer Range ............... 37 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Sensible Load ..................... 48967 36311 Latent Load........ ............ n/a 7509 ----------- ----------- Minimum Total Load 48967 43820 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Cooling Description (Btu/hr) ----------- .(Btu/hr) ----------- --------------------------------- Opaque Conduction and Solar...... 20483 10216 Glazing Conduction and Solar..... 68'58 11207 Infiltration ..................... 12882 4922 Internal Gain .................... n/a 2520 Ducts ............................ 8744 7446 Sensible Load ..................... 48967 36311 Latent Load........ ............ n/a 7509 ----------- ----------- Minimum Total Load 48967 43820 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING HVAC Page 12 -------------------------------------------------------------- - Project Title.......... ADAM & NICOLE HUEY Date..12/04/07 18:14.49 ------------------------------------------------------------------------------- MICROPAS7 v7.10 File-HUEY Wth-CTZ11S05 Program -HVAC SIZING I User#-MP2246 User -Barry Rubanoff Run-HUEY ------------------------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY BY ZONE ---------------------------------------- ZONE 'ZONE1' Floor Area............ 1648 sf Volume ........................... 14832 cf Description Opaque Conduction and Solar...... Glazing Conduction and Solar..... Infiltration ..................... Internal Gain .................... Ducts............................ Sensible Load... ............... Latent Load ................. .... Minimum Zone Load ZONE 'ZONE2' Heating (Btu/hr) 10672 5189 7103 n/a 4992 27955 . n/a 27955 Floor Area...... ................ 1341 sf Volume ........................... 12688 cf Description Opaque Conduction and Solar...... Glazing Conduction and Solar..... Infiltration ..................... Internal Gain........ .......... Ducts............................ Sensible Load .................... Latent Load ...................... Minimum Zone Load Heating (Btu/hr) 9811 1670 5779 n/a .3752 21012 n/a 21012 Cooling (Btu/hr) 4682 8478 2714 1386 4452 21713 4490 II�� Cooling (Btu/hr) 5533 2729 2208 1134 2993 14598 3019 1.7617 AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 Recorded I EC FEE Official Records I County tte f CONFORRED COPY CRPIDRCE I BRUBBS I County Clerk-Recorderl I I BW 0911 09 -Oct -2006 I Page 1 of 2 10.00 1.00 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: Date k(� `1`3 0 G State of California County of -�&]Ai---n:5 PROPERTY OWNERS: On LO - `"I - O Co before 11` Gl,tm Gli t'� U - we-/ T - Q-C-)Z>T-PN . IVB i r-� t' L& 0 LV C_ personally appeared-- PcpAyM L3 . -t�CAE ► Aj\Wo M� t� .l✓ -Pfu� { personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) ed, ex cuted'the-i ument. WITNESS m h inn a'Ijfi' a . Signature t , Seal: 4 _ C.C. Costa A.P. #,`_ Q 9 Q-0 Commission #15174790 U Notary Public -California Butte County My Comm. Exp. Oct. 30, 2008 Escrow No.: 06 -108398 -TG Locate No.: CAFNT0958-0958-0001-0000108398 Title No.: 06 -108398 -BEE EXHIBIT "A" THE LAND REFERRED TO HEREIN BELOW IS SITUATED IN THE UNINCORPORATED AREA, COUNTY OF BUTTE, STATE OF CALIFORNIA, AND IS DESCRIBED AS FOLLOWS: Parcel I: A portion of Lot 75, as shown on that certain Map entitled, "Official Map of Oroville-Wyandotte Fruit Lands Unit No. 3", which Map was filed in the Office of the Recorder of the County of Butte, State of California, October 10, 1927 in Book 11 of Maps, at Page(s) 19 and 20 and being more particularly described as follows: Beginning at the most Northerly comer of said Lot 75, said comer being also in the centerline of Apica Avenue, as shown on said Map; thence South 00 55' West along the centerline of said Apica Avenue, being the East line of said Lot 75, a distance of 278.06 feet; thence leaving the centerline of said Apica Avenue, South 540 45' West, a distance of 681.23 feet to the true point of beginning of the land herein described; thence from said true point of beginning, continuing South 540 45' West, 135.0 feet to a point in the Northeasterly line of that certain Parcel of land described in Deed from Harry 1. Nott, et ux to Loren W. Quigley, et ux dated April 11, 1956 and recorded April 16, 1956 in Book 824 of Butte County Official Records, at Page 199; thence along said Northeasterly line, North 460 12' West a distance of 344.26 feet to a point in the centerline of the Oroville-Wyandotte Irrigation District ditch right of way, as shown on said Map; thence along said right of way and along the Northwesterly boundary line of said Lot 75, the following courses and distances: North 790 13' East 38.08 feet; thence North 690 36' East 30.00 feet; North 430 56' East 75.0 feet, more or less to a point which bears North 460 12' West from the true point of beginning; thence South 460 12' East 359.77 feet, more or less to the true point of beginning. Parcel II: A right of way for road purposes 20 feet in width lying 10 feet on each side of the following described centerline: Beginning at the most Northerly comer of Lot 75; as shown on that certain Map entitled, "Official Map of Oroville- Wyandotte Fruit Lands Unit No. 3", which Map was filed in the Office of the Recorder of the County of Butte, State of California, October 10, 1927 in Book 11 of Maps, at Page(s) 19 and 20, said comer being also in the centerline of Apica Avenue, as shown on said Map; thence South 00 55' West, along the centerline of said Apica Avenue, being the East line of said Lot 75, a distance of 278.06 feet to the true point of beginning of the line to be described; thence from said true point of beginning, leaving said centerline, South 540 45' West a distance of 816.23 feet to a point in the Northeasterly line of the certain Parcel of land described in Deed from Harry 3. Nott, et ux to Loren Q. Quigley, et ux dated April 11, 1956 and recorded April 16, 1956 in Book 824 of Butte County Official Records, Page 199; and the end of said'line. Excepting therefrom that portion lying within Parcel I above described. i LOA COURT a 294.55 DRAWN BY, B, RUBANUEF zT--i CHECKED, DATE, 3-9-d5 SCALE AS NOTED JC]BI HUEY SHEET # 2 OF 2 ,-6, ,_Q„ _®-6,-6,» 12'-0" - 34,-0" 17'-0" -- 3'_p„ ,_p„ Lo 3'-O" --�-� 11'-3"---�'-9" Cri 1 A N 2�„ ,_6 » „_2 „ 2'-6" 3'-6" 3'-6" 2'-6„ 3, -fig„ 2 ,_7„ 7'_5 " 11'-0" ,-2° '_6„ —2'-9„ ILL. Lj G�6 �;6 I o < c'4 LL! Z 4050 SL. N z LLJ m 0= a 00 o r EGRESS xmi rn U J COV. DECK a w In 1 I o B a I '� 2 2668 1 m CL M "I I I II I I I I r I o W.I.C. r 183 N 3050 SL. 305 SL, I I ( LS&P � _ DECK I 1 i BEDROOM #4 6 0 W 60 0 SL. GL. DR. HB. I � �� CFG. XTUB/72 p'F G 3050 SL. 3050 SL. 3050 SL. ______ SHOWER `i' ° r COV. DECK TEMP. CL ®7 I o 'ZERO' CLEARANCEH — -- u Q FIREPLACE & I I I I J I x HEARTH. INSTALL o , o �' � I N _ I a- I PER MANF. SPECS _3. I I ( I 0 1 H N� I NOOK 2668 BATH 0 r s 0 I 1 I I S&P M c° 3-3050 SL. W/3- I P N, r _ 3010 FIX ABOVE L �r I ZERO CLEARANCE I I w AC AD I _,:,.: 12'-11„ 3'-3" i� GAS STOVE & z o0 �.0 __ HEARTH. INSTALL 1 2 WALL 9 CL G. (VAULT co :i- „ PER MANF. SPECS c� MASTER BEDROOM N 2 -' EATING BAR 868 266a P L) CENTER LINE OF 'VAULT �- I ::..............::: RAL N0�!'IES ,:a \ — _. —BENE Q 1,.� \Io ® „ er i 1. 'ALL LUMBER 'TO BE DOUG FIR 2 w L IN��v) 1„ 7 I I � \, � N - ., ' .'.r:. --� •: v I ' AND. BETTER, STUDS TO BE STUD # -5 cn -�-� A u,� OM I-"' ¢ `c --I M GRADE OR BETTER, UNLESS OTHERWISE NOTED FAMILY.. tO � vi .x 2. ALL HEADERS TO BE 6x12 D.F. UNLESS OTHERWISE NOTED 11 6 2,"0„ - „� _ 12,_4„ KITCHEN `�: '_3 " 3'-0" BEDROOM 3 ui' �� It-- # — - I 3. ALL CEILINGS TO BE 9'-O" UNLESS OTHERWISE NOTED © Ci cam', 'V I I 1 UJ 4. PROVIDE 18"x24" FOUNDATION ACCESS AT EXTERIOR n ``� WITHIN 20'-0" OF PLUMBING CLEANOUT Ln DW �Id 5. PROVIDE OPENING AS REQUIRED AND CONCRETE SLAB 04 MEDIA ROOM I FOR H.V.A.C. A wIN1 VANITY o o .-�, NICHE ' i REF. J�� `O•,x 28613 6. INSULATE AT TUB AND SHOWER EXTERIOR WALLS BEFORE NAILING TILE I JQ a� AN UP SIDING SHOWER , i�, I 2'-8" ,> 7. SEE TITLE SHEET FOR ADDITIONAL NOTES 4 -6 3 8. PROVIDE P.T. VALVE, DISCHARGE LINE TO OUTSIDE & ANCHOR STRAPS ti TOP & BOTTOM AT WATER HEATER 2668 r o 0 - --- Fi arm NICHE �Wn c D, nni c ti�� 9. BLOCK FOR TOWEL BARS DRAWN BY, B. RUBAN❑FF CHECKED: x 3-9-06 SCALE JOBt �I o SHEET 1 # OF 2 C14, REF. J�� `O•,x 28613 6. INSULATE AT TUB AND SHOWER EXTERIOR WALLS BEFORE NAILING TILE I JQ a� AN UP SIDING SHOWER , i�, I 2'-8" ,> 7. SEE TITLE SHEET FOR ADDITIONAL NOTES 4 -6 3 8. PROVIDE P.T. VALVE, DISCHARGE LINE TO OUTSIDE & ANCHOR STRAPS ti TOP & BOTTOM AT WATER HEATER 2668 r o 0 - --- Fi arm NICHE �Wn c D, nni c ti�� 9. BLOCK FOR TOWEL BARS DRAWN BY, B. RUBAN❑FF CHECKED: DATE 3-9-06 SCALE JOBt HUEY SHEET 1 # OF 2 "7" t ,'-• �IYI