Loading...
HomeMy WebLinkAbout069-500-007I.A 069-500-007 PERMITN95-1364 SEEGERT, Chris & Mary 35 Lariot Loop, Oroville New Single Family11t� to f'� M� M� �. RESIDENTIAL 069-500-007 PERMIT#95-1364 SEEGERT, Chris & Mary 35 Lariot Loop, Oroville New Single Family —715176(,, OFFICE COPY Address I GAS Meter By Dat .l ELECTRIC Meter By B DDet ELECTRIC Meter By�- Date JOB FINALED (Date) Signature II tt a�_ J=OK O = Not OK = Not Applicable Not Fieady MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s DECKS, COVERS, "RPQRTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 1. Zoning Requireinent4'Setbacks- Ease ments 2. Soils; Special MH Support Sketch 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Sewer; Location -Test -Fall -C/O Concrete 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4. Wood Awn.; Posts- Bea ms- Rftrs.-Con nectors Shthg.-Rfg.-Bracing 5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; Location -Test -Wrap: / /" L" ft. / /"Nat. or/ /"L"ft./ /"LPG 6. Carports; Windows -Doors 7. Well Clearance R Disconnect 7. Electric 8. Utility Clearance 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements ' Card B-1 Date Card B-1 2. Footings; Size -Spacing -Marriage Line Card B-1 Date Card B-1 3. Gas; MH Test -Demand -Valve -Connector POOLS (Plans) OK except #'s 4. Electricity; MH Test -Crossovers -Breakers -Clearances 1. Setbacks -Easements 5. Drain; MH Test -Fall -Flex Connector 2. Soils; Compaction -Structure Stability 6. Water; MH Test -Regulator -Connector 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 7. Water and Sewer Connected -C/O to Grade -HD Approval 4. Elec.; Receptacles and Lighting, Distances-GFI 8. Gas and Electricity Tagged 5. Elec.; Pool Lighting; 15 volts-GFI 9. Exits; Insp.-Sketch 6. Elec.;Enclosures; Conduit Entries -Terminals -Listed 10. Cert. of Occupancy 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. _ Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCLANEOUS Date DECKS, COVERS, "RPQRTS, GARAGES, (Plans)OK except #'s 1. Zoning Requireinent4'Setbacks- Ease ments 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Bea ms- Rftrs.-Con nectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.;Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. _ Boxes -Enclosures -Panel boards -Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ✓=OK O=Not OK -=Not Applicable Not Ready RESIDENTIAL (Single ' = Date UND LOOR (Plans) OK except ti's c ing-Setbacks-Easements-FI - lope tc4,e#ain; Soils-Elec. Grn tg. Depth . tg., Garage; Soils-Steel-Ele . Grnd. j Ftg. Depth - - 4. F!q., Porches & Decks; Soils -Steel-/ /Ftg. Depth -' 115,"S -tern all's, Main; Steel-Blockouts-Wrapped -- emwalls, Garage; Steel-Blockouts-Wrapped------- 6a. Hold Downs and SDecial Anchors ------- & Duplex) Date FRAMING (Continued) ---- H gers-Post Caps -Anchors -Connectors CIng. Joist-Rftr. ties-Purlin-roof Brac-Truss-Shthng.-Ring. 7. Slab; Steel -Wrapped 8. Pie Fireplace Ftg.-Steel D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 1.4 ,rders-Sills-Anchor Bolts -Joists -Vents -Cripples da�ccess & Ventilation 16. Insulation Date264.'Card B-1 Date Card B-1 Dat f Card B-!:t5EDate Card B-1 Date PLUMBING ( ermit),OK except a's er Htr.. Vent -Access -Combustion Air -Baffle --------- — - --- ------------------------------ -- ter Pipe; Test & Anchor -Nail Protection -- - -- D.W.V.; Test -Fittings & Anchor -Nail Protection-- - - -- - 19.. Shower Pan; Test, First Floor -Tub Access ---- - — 20. Test Tub & Shower. Second Floor -Tub Access as Pipe: Size & Anchors Date --------Card B-1 ------- Date ----- ----Card-B-1----------- Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except ft's - --- -a2-'F, re & Transformer Clearance -Ins. Protection le Receptacles Spacing -Lights & Switches at Doors --------------- -- - ---- ------------------------------------- ----- _ Siz oxes & No. of Conductors -Stapled --- - - ----------------------------------------------------- - __ o x Installed Close to Edge of Studs & C.J. --- - qui (Ground made-up w/Meth. Fastners-Bond Gas & Water Appliance Circuts in Kitchen & Conductor Size/GFI ------- - ------------------------------------------- - - 28. Subfeed Wire Size / i ga. Cu or AI-A.C. Wire Size / / ga. Cu or At 29. Range Circ / I ga Cu or AI Oven Circ. / / ga. Cu or Al. Insulated Neutral ❑ Yes ❑ No -------------- 30 ervice-Riser --Con - ductors & Ground -Main Disconnect 31. u , Clearances Panels-Motors-Mech. Equip. ---------------- ------ ----------------------------------------------- 32 ------------- - 32. othes Closet light -Shower Light -Spa Light ---------- ---------------------------------------------------- ---- 3'i poke Detector ----------------------------------------------------------------------------------- Date Card B_1 Date Card -6- 1 ------------------ ----------------- ---------------- Date Card B-1 Date Card B-1 Date MECHA CAL (Permit) OK except P's A.C. acts Insulation & Support ------------------- --- ---------- ent Fan Exhaust above insulation ------------------------------------ 36 Condensate Drain & Overflow: Size & Grade 37. Furnance-Vent: Access -Comb Air -Return -Air Vent -115 -outlet ---------------------------------------------- 38. Attic -Access-&. Platform if Furnance in Attic ------------------------------------------ ------------------------------------ Date Card B-1 Date Card B-1 --------------------------------------------------------------- - ---------------- Date Card B-1 Date Card B-1 Date FRAM.JNG (Plans) OK except a's Sit Proper Material & Anchors ------ Var Studs -Nailing. Spacing & Bracing -Plates -Sound -------------------------- ---- -- --- e ing Walls over Girders &Floor Nailing -- --- - - --- ------------- Dr Stop in Walls (rat proof) Fire Stops: Furred Ceilings -Stairs -Chases -Tub ------------------- - - - --------------------- eaders & Beam -Size & Bearing A Flue -Fireplace Throat clearance ccess: Size & Romex Protection -Draft Stop -Ins. Baffles Windows or Exiting Doors -Sill Hgt. & Dimensions Fire Protection Framing tv Line Firewall & ODeninos ,52E oors-One 3' -Check Garage -3rd Story, 2 Exits 52-"Stair,s- Width -Head room -Rise -Run- Land ino-Fire Protection 54!plyJyo6d on Roof Overhang -Attic Vents -Rafter Outriggers 510 -Siding -Nailing Veneer ---- --- o esh-Drip Screed -Fd. Vents-Underflr. Access G zinq Area -Glass Protection -Skylights-Plastic -- --- ct`r6 ear Walls; Nailing -Bolts ----------- ---- Insulation-Walls-Ceilings -------------- 60. Infiltration -Walls -Windows Date/6f y/ ��- Card 8��-- Date _ Card B-1 Date i Card B=1 Date Card B-1 Date FINAL ns) OK except #'s -------- - ------ I. - s -Door &Sidelight Protection -Landings mo _ etector _ urnace: Vents -Clearance -Comb. Air -Connector - In G e; Above Floor -Ducts -Meth. Protection _ _ e m_Exiting --- -___---- --. G/.FyR Bath Fixtures & Tub Access -Spa 6ff Trim & Subpanel; Breaker Sizes & Labels ---r's & ails ------ 7. Stairs & Rails -------------------- r -- Stove: Clearances -Hearth —-------- leqets at Wood Panel: Int. & Ext. Kit.F' Appliance; Grnd_Air Gap -Cooking Clearance Receptacles at Kit. Counter - ara Fire Door; Swing -Landing -Closer zp<c. Du in Garage -Damper 7 r. Htr Vents -Clearance -Comb. Air-Connector-P.R.V. In ge: Above Floor -Meth. Protection Mech. Equip. Listed for Location let. eceptacles in Garage: (G.F I.)-Romex Protection -- - -- ----------- - - -- nslatio _-Foam-Looked in Attic ❑ Yes -------u- --- - --- --------------- 7 uerd Rails & Deck Construction -Post Caps 7 n & . Vents Crawl Hole Door -Drainage & Wood -Earth Clear ce Looked under Floor ❑ Yes 90�-110-11owing instld. Drive ❑ Yes ❑ No: Walks ❑ Yes ❑ No; Plant cs-'❑ Yes ❑ No uc -•: Brown -Finish ------------------------------------- -- d@�A.C. Unit: Disconnect. Electrical, Plumbing ents Above Roof: Plbg.-Appliance-Fireplace.-Clearance to Ope Ings _ ate ell; -Disconnect, Electrical, Plumbing -- -- --- ----------------------- xte r Elec. Trim; G.F.I. Receptacle -Underground ------------------- ry on Throughout House ...--Gla Protection --------------------------- -- - -------------- -- ------------------- -- ---- Corrections from Previous Inspections 8GTest-Meters Tagged; Gas -Electric W & Sewer Connected -C/O to Grade -HD Approval Energy Compliance Certificate -Other Certificates Date _Card B- Date _ Card B-1 ---- - -- ------ -- - --- ------ Date / Card -1 Date Card B-1 ---- -------- ---- Card ---------------- — Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive - Oroyille, California y5965 - Telephone (916) 538-754 PER O. APPLICATION AND PERMIT �� ASSESSOR PARCEL NUMBER 69-500-007 R1 ZONING BUILDING PERMIT 17 OWNER CHRISTOPHER SEEGERT/MARY E. SEEGART TELEPHONE 589 2986 SO. FT. OCC. BUILDING VALUATION OWNERS MAILING ADDRESS 6103 OLD OLIVE HWY 7'920 CONTRACTOR'S NAME CHRISTOPHER SEEGART TELEPHONE90 C 260 CONTRACTORS MAILING ADDRESS SAiME Fireplace CONSTRUCTION LENDER UNPQ40WN Total Valuation $ 76 22 LENDER'S MAILING ADDRESS Fling Fee $ 20.00 Permit Fee $ 536.00 ARCHITECT OR ENGINEER CHRISTOPHER SEEGART LICENSE NO. Plan Checking Fee $ 348.40 Energy Plan Checking Fee $ 23.00 ARCHITECT OR ENGINEERS MAILING ADDRESS SAME Penalty $ BUILDINGADDRESS VILLAGE OAKS UNIT 12 PERMITFEE $ 27 35 LARIAT LOOP PLUMBING PERMIT Fling Fee20.00_ Each Trap p, 7.00 56.00 LOT NO. 231 SUBDIVISION'S NAME PARn M154 VV Solar Or heat pump Water heater 23.00 USE OF STRUCTURE SF )7 Duplex ❑ Mobilehome ❑ Other SPECIFY Water piping 15.00 15.00 Each gas water heater or vent 15.00 15.00 Gas piping system 1 - 5 outlets 15.00 15.00 Building sewer 15.00 5.00 TYPE OF WORK New E)( Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 1 R^PRnM4 Mobile Home I S I G W 1 920.00 PERMITFEE $ 136.00 Contractor ELECTRICAL PERMIT Filinq Fee 20:00 Main Service% -"A OR- 'E'ESSs ( zoos ) 23.00 Main Service ( 200A TO I000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. n g S f �I OWNER -BUILDER DECLARAT ON 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason NEW CONST. DWELLING OCCUP. OR ACDNS. ( 8 ACC. BLDS. ) SO. 3.Sa FT. c;8 85 NEW CONST. MULTI.OUTLET NON-RESID. ( BRANCH CIRCUITS ) 97.50 ( POWER APPARATUS ) 8 SINGLE OUTLET CIR. Ex. Occup. (OUTLET OR FIXTURES) zL Q I•50 BAL Ex. Occup. OUTLETS RES D.) EA ( ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ 1. 5 Contractor WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insuranc carrier and policy number are: Carrier Policy Number (The above sections need notbe completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X ______ Date -___ Signature of pIi nt - ❑ Owner ❑ Contractor , gent An OSHA per t is required for excavations over 5'O" deep demolition or construction of structures over 3 stories in height. ff MECHANICAL PERMIT Filing Fee 20.00 Heating ._ Cooling Hood 6.50 Ventilation PERMITFEE $ Contractor Mobile Home Installation Fee $ Energy Inspection Fee $ OCC CONST.TYPE VN TOTAL FEE $' 1 272.25 — HAZ. D: FEES IMP FLOG CDF PARCE PD This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indi above r which fees have been paid. �Q� B �w to (Date) reiptNo. 451.40 - 180224 pPERMITEXPIRESONTE-D.D.S.-B.D. B CANARY-ASSESSOR PINK -INSPECT R GOLD NROD-APPLICANT i D ELOP,,MENTSERVICES - BUILDING DIVISION, COUNTY OF BUTTE - DEPARTMENT I_ � 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 -TELEPHONE (916) 538-7541 PERMIT ARPLICATION DATA SHEET OWNER A. P Proposed Building Use Building Inspect Date At time of permit application, I was advised the following data must be submitted prior to permit processing a d/or issuance: DATE RECEIVED BY 1. All items have been submitted . ........................................ 2. Plot plans, 3/4 sets, signed by preparer of plans . .......................... 3. Complete plans, 3/4 sets, signed by preparer of plans . ...................... 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............. IHazardous Material Form . ............................................ 6. Energy Design Compliance and supporting documentation . .................. 7 Statement of Intent for Non -Heated and A/C Buildings . ...................... 8. Engineered truss details and layout in duplicate (required prior to plan check). .... Mobilehome ata.and napu#acturer's installation instructions, 2 sets. ........... Adfees of $ 017 ........................... pact fees as shown on attached schedule. ... ............ California Department of Forestry plan approval jo1.�?r .. .. 13. Flood elevation letter (100 year flood)qbalifarnia Engineer . ................. c Sanitation and plot plan approval ealth Department . ............� 15. City of Chico plumbing permit. ........ . 16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: 18. Contact Land Development about (A) Improvements (B) Drainage. .......... . 9. Driveway permit (construction approval required prior to occupancy). .. .. r ... . 1 1,1nspedion roque Pre -inspection for required. .. to Building Inepeaor �oace� a. Contractor's license information. (No., Name Style, CIa ssification). .............. 22. Certificate of Workmans Compensation Insurance. . .:................ . nor-Bui el er � ail to owner�. .........:: ������ 24. Recorded copy of Agricultural Acknowledgement Statement . ............... . 25. Letter of signature authorization . ........................................ 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . 27. Letter of intent on building use . ......................................... 28. Mobilehome utility clearance . .......................................... 29. Documentation of legal access . ..................... :.................. 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... xisting violations/expired permits . ...................................... Plan checklist ...................................................... 33. Whp,ydu' issue the permit, process a follows: Mail to owner. Mail to contractor. f/ Telephone_, '9:� &hold for pickup at �j office. Deliver with inspector. Other Parcel Creation � df�� Acreage Applicant 00"w4et Date r � Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date _ The following data must be submitted ri r t rm iss A;hka ce: (' le new i e d above). 1. Index permit for above items No.A Z 2. Additional items required: By Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Contractor, designer, owner, was advised of above required data by _ phone _ mail Co to by _ Date Plans checked by (� Date Z Plans approved by Date Sets of plans on hold in File cabinet AP foldero�?�a�� Y Copy - Department of Public Works `../� v - COUNTY OF BUTTE — DEPARTMENT OF DEVELOPMENT SERVICES — BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 — TELEPHONE (916) 538-7541 OWNER PROPOSED BUILDING USE SCHOOL DISTRICT FEES (paid at District Office)........... ........... 2. SHERIFF FEES (paid at Building Department) Residential...... x unit amt. Commercial (sgft) x =$ sq.ft. amt. A.P. DATE'ZZ lO REC. # DATE REC 7/S -h S 3. URBAN AREA FEES (paid at Building Department) Residential (per unit) x =$ # units amt. Commercial.(per sq.ft) x =$ 4. sq.ft. amt. RECREATION DISTRICT FEES (paid at District Office) ......................... 5. DRAINAGE DISTRICT FEES (Contact Land Development Division) .............. L96. SRA FIRE INSPECTION AND PLAN CHECK = $89.00...... (paid at Building Department) 7. OTHER 8. OTHER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. APPLICANT DATE p7�OUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 PERMIT NO. APPLICATION AND PERMIT �Sa� ���— ASSESSOR PARCEL NUMBER _S-oZO"I"G r0 027 .4,eZ BUILDING PERMIT o,,,, � TELErIa"E2q4Y C�O SO. FT. OCC. BUILDING VALUATION OWN S MAILING DR S CO CTO 'S NAM TELEPHONE ��M/O C, CO TORS MAI NG ADDRESS Fireplace os— CONS LENDER UNIG40WN Total Valuation $ 62 Filing Fee $ 20.00 LENDER'S MAILING ADDRESS Permit Fee $ O NGIN LICENSE No. Plan Checking Fee $ 'p Energy Plan Checking Fee $ ARCHITECT OR ENG EERs MAILING Ess Penalty $ Sul IN AD _1 1• `J PERMITFEE S ' PLUMBING PERMIT Filing Fee 20.00 ljL('v Each Trap Bf7.00 T SUBDNISIONSNAME P MAP Solar or heat pump water heater 23.00 Water piping 15.00 USEOFSTRUCTURE SF Duplex ❑ Mobilehome ❑ Other SPECIFY Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 TYPE OF WORK New Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work:��% Mobile Home S G Ew @20.00 PERMITFEE $ ,(J Contractor ELECTRICAL PERMIT Filing Fee 20.00 Main Service000v OR LESS ( 200A OR LESS ) 23.00 Main Service ( 200A TO 1000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason NEW CONST. DWELLING OCCUP. OR ( a ) so. 3.5¢ Fr. CNS. LTI-ACCUTLEBLDS NEW CONST. MULTI -OUTLET NON•RESID. ( BRANCH CIRCUITS ) 97.50 POWER APPARATUS (a SINGLE OUTLET CIR. ) EX. Occup. ( OUTLET OR FDRURES ) 20 Q 1.00 BAL Q .50 Ex.. Occup. (oFIXEEDrs P D.OR ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ 10 , Contractor WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed 0 the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Filing Fee 29.00 Heating DO Cooling ,a Hood 6.50 Ventilation PERMITFEE Contractor Mobile Home Installation Fee Is Energy Inspection Fee 1$ Q 3 cop'.PE TOTAL FEE $2 HAZ. I D. FEES IMP FLoK I CDf ARCEL HD ISSUE This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have By PERMITEXPIRESON I the applicable provisions Resolutions to do work been paid. Date (Dare) Receipt No. '7 y(/ i / WHITE-D.O.S.-B.D. Y -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT x^ BUTTE COUNTY SCHOOLS IMPACTTEE CERTIFICATION FORM (One Form Per Building) School District Di? (� �. -El/ l Building Department No. A. P, Number 6p7sdU"®O -7 Jurisdiction: = CityCounty Property Owner / .5- X ,S f�Cv45 Property Location/Address _—_T46/,?/Ar- r//,?/A%— Zoe;p O%- C/ Subdivison Lot No, Residential Development Sq. Footage 7-5 No. of Living MHI Addition (Group R) Units Commercial/Industrial New Addition (Floor Plans reviewed by School District Personnel) District Identification No. / q9_5 (Street Ai Sq. Footage (Including Exterior Roofed Areas). Date School District certifies that -CIof r (Applicant (Phone Number) 4.i9 6 to (City) (State) (Zip Code) has complied with the requirements of Resolution No. t q3 -'?'/—/0 by payment of, $ _2 /8 representing square feet. AB 2926 $ PULL MITIGATION $ School District Representative Date Paid by Check # // Remarks'. Bank Number _ Xp *9 j x_10 Paid by Cash If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeformmk, (11/94)dmm And when recorded mail to: Building Division #7 County Center Drive Oroville, Ca. 95965 ,' 95-022004 41"1:_ 0 51995 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code requires this acknowledgment to be recorded prior to issuance of a building permit. The propert described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers: and from the pursuit of agricultural operations including, but not limited to cultivation. plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise. and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal. necessan. farm operations. All that real property situate in the County of Butte. State of California, described as follows: L t:' 0"Z �- 0 2f /? G / WC -7 t.7 ,C 0 L (� L Date: C� State of California Countv orz�e R`P_ C04'11r- O cf— j ` X (" y e5' PROPERTY OWNERS: (3q Ht t• t-16/ On / before personally appeared ma r (f • se -e erf personall. known to me (or proved to me on/the basis of sati9factory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that bv.his/her/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal. OFFICIAL SEAL REBECCA L BLEDSOE C NOTARY PUBLIC -CALIFORNIA ao COMMISSION It 986238 BUTTE COUNTY Signatu e 0pF' /c�Q Seal: �. My Commission bp. Feb. 28, 1997 A.P.# �9-s--moo- 0�7 PERMIT NO: 23-95 Lake Oroville Area Public Utility District 1960 Elgin Street OROVILLE, CALIFORNIA 95966 533-2000 DISTRICT APPROVAL AND VERIFICATION OF INSPECTION BUILDING SEWERS This verification form must be submitted to the.Butte County. Department of Public Works Building Department prior to issuance of a building or occupancy permit, whichever is applicable. Prior to final approval by Butte County of a Building or an Occupancy Permit, a copy of this verification form, signed off by Lake Oroville Area Public Utility District, must be submitted to Butte County. Date: July 5, 1995 Applicant: CHRISTOPHER & MARY SEEGERT Applicant Address: 6103 Olive Hwy, Oroville, CA 95966 Applicant Phone No.: 589-2986 Property Location (S): 35 Lariat Loop Village Oaks Unit 2 - Lot 23 A. P. No. (s): 69-50-07 Fees due: $200.00 Annexation Fee, $35.00 Connection Fee & $900.00 SC-QRnFacility Charge Due. Application for service approved: LAKE OROVILLE AREA PUBLIC UTILITY DISTRICT Inspection(s) made and successful test(s) observed: Location: M Date: Lake Oroville Area Public Utility District release to close permit: Date: By: LAND DEVELOPMENT - BUILDING PERMIT CLEARANCE~ Building Permit No. A.P. n NAMERS 'tom r 'NUMBER: PRINT LAST FIRST COUNTY ZONING 3?IT B DESIGNATION: /' FLOOD ZONE: X FLOOD MAP: APPROVED: CONDITIONALLY APPROVED: RESOLVE PROBLEMS PRIOR TO APPROVAL: DATE OF CREATION: PARCEL CREATION BY DEEDS DEED REFERENCE: LEGAL ACCESS PROVIDED: YES NO LEGAL ACCESS REQUIRED: YES NO COMPLIES WITH COUNTY STANDARDS FOR DEED CREATION: YES NO COMMENTS/CONDITIONS PARCEL CREATION BY MAP V,t-L�A-GE 0 A4 0 r DATE OF RECORDING / /-7 7 LOT 2 3 BOOK SS PAGE Z'�¢ COMPLIANCE WITH OLD SUBDIVISION LOT ORDINANCE REQUIRED? (MAP RECORDED PRIOR TO BOOK 17 OF MAPS AT PAGE 23): YES NO . IF YES, MARK APPROPRIATE ITEM(S) BELOW: A. Construct road to B. Meet parcel size required by zone. C. Meet current E.H.D. requirements. CHECK SPECIAL CONDITIONS WHICH APPLY TO MAP: ALL FEES TO BE PAID TO THE BU/LD/NG DIVISION UNLESS OTHERWISE NOTED. 1. Maintain a 50 ft. building setback from centerline of road. 2. Maintain a building setback from right-of-way/centerline of 3. Pay water tender fees in the amount of $ to Battalion Number of the Butte County Fire Department. _ 4. Automatic fire suppression sprinkler systems shall be installed in all residential structures in accordance with the National Fire Protection Association Standard for the installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet Fire Department specifications, serves the parcel. 5. Pay T.D.D. (Thermalito Drainage District) fee in the amount of $ 6. Maintain a 100 ft. leachfield setback from all existing wells. 7. Maintain a ft. leachfield setback from 8. Meet the requirements of the Department of Fish and Game for the preservation of oak trees. 9. A traffic mitigation fee for each new or additional living unit shall be paid. Pay the amount of $ as stated in the Oroville Area Traffic Mitigation Fee Agreement. Payment to be made to the Planning Division. 10. All new residential buildings shall be constructed to comply with the requirements of the Uniform Building Code for seismic safety. Mobile homes shall be constructed on a permanent foundation system which complies with the Seismic Zone 3 requirements of the Uniform Building Code. 11. Deer Mitigation fees are to be paid, if such fees have been adopted by the Butte County Board of Supervisors. 12. CHECK APPROPRIATE REQUIREMENTS YES OR NO OR CONDITION NUMBER. LD 12M - C:1WP51\F0RMS.K%8LDGPERM.CLR . 4 OF sUTTE jUN9. 6 1995 _,,-Ici uevelopment'Sec. RESIDENTIAL' PLAN CHECIQNG GUIDE SINGLE FAMILY DWELLING, DUPLEX AND MISCELLANEOUS ONLY OWNER: ��''-� BUILDING PERMIT NUMBER: PLAN CHECKER: �(% -�1 ASSESSOR PARCEL NUMBER: GENERAL 1. Zoning requirements: (sideyards and number of permitted living units). 21"'Valuation. GoaQ�E� 3v -Plans signed by designer. 4,c-Pr0 escription of work on application. Existing violations on property. ��ems on data sheet, (Impact fees, Health, Developer fees, License law, etc.). Recorde notice of violation. PLOT AN: 0j/ pfiND l W G C pr L •� Complete parcel size and dimensions. 2,-S'etbacks, sideyards, easements, etc. _1--Gder-buildings or structures. fills, and dtainage. Flood hazard. ,6---g-p—ecial conditions on creation map, (noise, C.D.F., fire sprinklers, non-combustible, and foundations). 7--FA-U & FAS road setback. A—B-uutding or utilities across lot lines (Record form). F1:Q0R PLAN:•, . - I2mplete to"scale plan with -'dimensions ` --* 'quired windows for light and ventilation (Section 1205). _ .. Re aired windows for second exit (Section 1204). ,Skylights (Chapter 34 &Section 5207). y *',Human impact glass (Section 5406). Required room sizes, ceiling heights (Section 1207). o .a----G.F.C.I. in baths, garage, kitchen, and exterior outlets (Article 210-8): P ,8-.- jE5 t fixtures, switches, receptacles, and exterior receptacles for maintenance of mechanical equipment. Y ations of water heater, heating and cooling equipment, other electrical or gas equipment. 1e G e firewall, door size, and closer (Section 503(d)(3) ). 1 - 3'0" exterior exit door (Section 3304 (f). PPee and wood stove location, alcoves and clearance. oke detectors (Section 1210). 1# -'Plumbing fixtures, water closet clearances and shower size. ST&iTCTURAI. DETAILS: it"'Standard bracing or engineered design (Table 25V). nusual shape, size, or split level house requiring lateral design. j3—C elstory requiring balloon framing and/or engineering. ory building requiring engineered calculations and plans. oundation plan complete enough to construct building. V./Floor construction details complete enough to construct building. elevations and wall construction details complete enough to construct building. �! Roof construction details complete enough to construct building. rep ace construction details and cals if necessary. 1 er ties or bearing ridge beam. 1arage door or porch header sizes. 1 ,Stud heights. T� 3/ obe soils -special foundation design. etaining walls requiring design. Special Inspection required. RESIDENTIAL PLAN CHECKING GUIDE SINGLE FAMILY DWELLING, DUPLEX AND MISCELLANEOUS M][Sj2ELLANEOUS ITEMS TO LOOK OUT FOR: _Stairway _details: landings, rise and run, head clearance, handrails (Section 3306). �G�drail details (Section 1711 and 33060). B • r stone veneer (Chapter 30). Exterior plasier - weep screeds (Section 4706). ,��per roof pitch for roof covering (Chapter 32). 6: -'Roof covering type - (fire hazard). oam insulation - protection. 36" halls and stairways. ea over garage - complete 1 -hour separation required on garage side including supporting walls and posts. o exits on three-story dwellings (Section 3303 and see Mezzanines - 1716). AWc access and ventilation (Section 3205). 12'—Underfloor access and ventilation (Section 2516). WCombustion air for fuel burning appliances - L.P>G. requirements: -1•��e requirements on duplexes. 1 E3' design. 1fr Flashing at all exterior openings. 1 D.F. responsible area requirements. PICV -It> 26- 9 5 �!:t` �. .�,. .� ,-.�,..Y ..z,��^•'�;r ;;R -.tri }" , s°�: qrt' `�;t "fit < }y. ,�^,�� `�"�'?�< a s• r rMilm Au: 23-95 Lake Oroville Area Public Utility District 1960 Erin street OROVILLE, CALIFORNIA 95966 533-2000 DISTRICT APPROVAL AND VERIFICATION OF INSPECTION BUILDING SEWERS This verification form must be submitted to the -Butte County Department of Public Works Building Department prior to issuance of a building or occupancy permit, whichever is applicable. Prior to final approval by Butte County of a Building or an Occupancy Permit, a copy of this verification form, signed off by Lake Oroville Area Public Utility District, must be submitted to Butte County. Date: July 5, 1995 Applicant: CHRISTOPHER & MARY SEEGERT Applicant Address: 6103 Olive Hwy, oroville, CA 95966 Applicant Phone No.: 589-2986 Property Location (s): 35 Lariat Loop Village Oaks Unit 2 - Lbt 23 A. P. No. (s): 69 -50 - Fees due: $200.00 Annexation Fee, $35.00 Connection Fee & Application for service approved: LAKE OROVILLE AREA PUBLIC UTILITY DISTRICT Inspection(s) m e and successful test (s) observed: Location: Date: 7--2o" 51'S By: U?, C , Lake Oroville Area Public Utility District release to close permit: f li Date: —/ / 66 By: ee Owner: LOCATION ROOF Material Thickness(inches) Permit No. ENERGY CER T I'T-ICATION C fb4'k 1 A. P. No. DESCRIPTION OF INSULATION Brand Name Thermal Resistance (R Value) EXTERIOR WAIL Material V—AW(-%`CLI;syp(� b Brand Name GC �(�' I M Thicknesa(inch ) '-Y IL Thermal Resistance(R Value) PJ CEILING Batt or Blanket Type Brand Name Thickness(inches) Thermal Resistance(R tnValu e) Loose Fill Type \�(J ' Brand Name U,`��.1 11 ry Minimum ThicknesW ies) �` Number of Bags ` Wt. per baQ ;1 lb. Area covered(ft. ) �a,3�j 'thermal Resistance(R Value), FLOOR, ELEVATED Material'FkbM �A ffjS Thickness(inch )_ to VLA" FLOOR, SLAB Material Thickness(inches) Width(inches) FOUNDATION WALL Material Thickness(inches) Brand Name M- ' -Thermal Resistance(R Value) Brand Name Thermal Resistance(R Value) Brand Name, Thermal Resistance(R Value) I hereby certify that the above insulation was installed in the above building in conformance with the State of California Energy Requirements. LOe�yp 1 c�Wwcon (b.-, 1AW i lb0 FIRM NAME,/OWnER STATE CONTRACTOR'S LICENSE NO, SfGNMURE OF I TALLA.TION APPLICATOR DATE I hereby certify the above insulation and all required items as shown on the Building Department approved plans and attachments have been installed as required by the State of California Energy Requirements. All equipment, devices and materials are of the quality prescribed or are specifically approved by the State of California. FIRM NAMC/ NER (Pleas 6rint) STATE CONTRACTOR'S LICENSE NO. SI TUR F Q .• CO CT OWNER DATE THIS CERTIFICATE MUST BE ON FILE WITH THE BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION APPROVAL AND A COPY SHALL BE POSTED WITHIN THE BUILDING. January 1984 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Residence for Seegert Date........ 06/26/95 Project Address........ LOT #23 - Village Oaks #2 Oroville 3 Documentation Author... Neal Kuopus Buil Per i Company ................ CALCTECH o 6- Telephone .............. (916) 534-5066 Plan Check Date Compliance Method...... MICROPAS4 by Enercomp, Inc. I -Fie C ec Date Climate Zone........... 11 MICROPAS4 v4.02 File-SEEGERCO Wth-CTZ11S92 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence GENERAL INFORMATION Conditioned Floor Area..... 1254 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 142 deg (SE) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Raised Floor (Package E) BUILDING SHELL INSULATION Component Insulation Assembly Type R -value U -Value Location/Comments Wall R-vll0.081 FRONT, RIGHT, BACK, LEFT y Wall R-z� 0.078 TO GARAGE, FAU/HWH CLOSET Door R-0 / 0.330 TO GARAGE, FAU/HWH CLOSET Roof R-38 / 0.025 FLAT CEILING Floor R-19 0.037 TO CRAWLSPACE ' FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (SE),/39.0 0.750 2 Drapes.Std None None Metal Door Front (SE)i/ 20.0 0.550 2 Drapes.Std None Yes Glz<50% Window Front (SE),' 45.0 0.750 2 Drapes.Std None Yes Metal Window Back (NW)/ 42.0 0.750 2 Drapes.Std None Yes Metal Door Back (NW),/40.0 0.770 2 Drapes.Std None Yes Metal HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R -value Type Furnace 0.806 AFUE Attic R-4.2 Setback Evaporative 11.00 SEER Attic R-4.2 Setback t3UTTE COUNTY BUILDING DEPARTKN? r-qf ._. P%_�� " -1 Cz 1 0 P y A.Ppp(-)Vpr) CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Residence for Seegert Date........ 06/26/95 MICROPAS4 v4.02 File-SEEGERCO Wth-CTZ11S92 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value Storage Gas Standard 1 0.59 EF 40 R-0 SPECIAL FEATURES/REMARKS R-4.2 duct insulation required R-19 floor insulation required per Form 3 NX R-38 ceiling insulation required per Form 3 Glazing U -values per MFR'S. NFRC testing & certification Viking or Milgard alum. frame dual -pane clear glazing req'd. FURN.806: RHEEM RGDG-075 w/0.806 AFUE @ 59,000 Btu/hr. output EVAP.11.0: 11.0 SEER w/ CEC MIN. REQ'TS. FOR EVAPORATIVE COOLING EVAP.11.0: 3.2 cfm / sq.ft. = 4013 cfm min. req'd. output EVAP.11.0: Provide ceil. vent'n. baffles & cont. ridge vent HWH: Rheemglas Fury 21VR40-7P X s USF_ -0- I4 u1/L(t)Ezc-3 QIbItoa -d.c oA=- -§a_ Z�r�aN CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Residence for Seegert Date........ 06/26/95 MICROPAS4 v4.02 File-SEEGERCO Wth-CTZllS92 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Chris Seegert Company. General Contractor Address. 6103 Old Olive Hwy. Orovill , CA 95966 Phone... (916) 9-2986 License. 29560 s r Signed.. (da e) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Neal Kuopus Company. CALCTECH Address. 1835 S. Villa Ave. Palermo, CA 95968 Phone... (916) 534-5066 Signed. . (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 4 1 MF -1R Project Title.......... Residence for Seegert Date........ 06/26/95 Project Address........ LOT #23 - Village Oaks #2 Oroville Documentation Author... Neal Kuopus Company ................ CALCTECH Telephone .............. (916) 534-5066 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Check/ Date MICROPAS4 v4.02 File-SEEGERCO Wth-CTZ11S92 Program -FORM MF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- ment *150(a): Minimum R-19 ceiling insulation. IG�� 150(b): Loose fill insulation manufacturers labeled R -Value. TUG *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 �� perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed.1� MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -1R Project Title.......... Residence for Seegert Date........ 06/26/95 MICROPAS4 v4.02 File-SEEGERCO Wth-CTZ11S92 Program -FORM MF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets ��^nnnggq certified by the CEC. 150(1): Setback thermostat on all applicable heating systems. 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. -���� r��L *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. f 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation VIC pump time switch. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.).� LIGHTING MEASURES Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. %��� COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... Residence for Seegert Date........ 06/26/95 2 - 'll Project Address........ LOT # 3 Vi age Oaks #2 Oroville Documentation Author... Neal Kuopus Company ................ CALCTECH Telephone .............. (916) 534-5066 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Check/ Date MICROPAS4 v4.02 File-SEEGERCO Wth-CTZ11S92 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 13.80 14.67 -0.87 Space Cooling.......... 15.90 14.80 1.10 Water Heating.......... 16.01 15.71 0.30 Total 45.71 45.18 0.53 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab=On-Grade Area......... Glazing Percentage......... Average Ceiling Height..... 1254 sf Single Family Detached New Front Facing 142 deg (SE) 1 1 ReducedYear Raised Floor 1 10032 cf 1254 sf 1254 sf 0 sf 14.8 % of FA 8 ft BUILDING ZONE INFORMATION (Package E) Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) HOUSE Residence 1254 10032 1.00 Yes Setback 2.0 n/a COMPUTER METHOD SUMMARY Page 7 C -2R Project Title.......... Residence for Seegert Date........ 06/26/95 MICROPAS4 v4.02 File-SEEGERCO Wth-CTZllS9.2 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence OPAQUE SURFACES HOUSE 3 Door Area U- Insul Act Solar Form 3 Location/ Surface (sf) n/a value R-val Azm Tilt Gains Reference Comments HOUSE Window 45.0 5 3 2 0.4 n/a 1 Wall n/a 441 0.081 R-15 142 90 Yes SW.15.2X4.16 FRONT 2 Wall 4 98 0.081 R-15 52 90 Yes SW.15.2X4.16 RIGHT 3 Wall n/a 166 0.078 R-15 52 90 No GW.15.2X4.16 TO GARAGE 4 Door n/a 18 0.330 R-0 52 90 No None TO GARAGE 5 Wall Window 266 0.081 R-15 322 90 Yes SW.15.2X4.16 BACK 6 Wall n/a 282 0.081 R-15 232 90 Yes SW.15.2X4.16 LEFT 7 Wall 116 0.078 R-15 142 90 No GW.15.2X4.16 FAU/HWH CLOSET 8 Door 20 0.330 R-0 142 90 No None FAU/HWH CLOSET 9 Roof 1254 0.025 R-38 0 0 Yes R.38.2X6.16 FLAT CEILING 10 Floor 1254 0.037 R-19 0 0 No FC.19.2X6.16 TO CRAWLSPACE FENESTRATION SURFACES # of Vent SC Sc Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 30.0 2 Metal Slider 0.750 142 90 0.88 0.78 Drapes.Std 2 Window 9.0 2 Metal Slider 0.750 142 90 0.88 0.78 Drapes.Std 3 Door 20.0 2 Glz<50o Hinged 0.550 142 90 0.88 0.78 Drapes.Std 4 Window 45.0 2 Metal Slider 0.750 142 90 0.88 0.78 Drapes.Std 5 Window 12.0 2 Metal Slider 0.750 322 90 0.88 0.78 Drapes.Std 6 Door 40.0 2 Metal Slider 0.770 322 90 0.88 0.78 Drapes.Std 7 Window 30.0 2 Metal Slider 0.750 322 90 0.88 0.78 Drapes.Std OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 3 Door 20.0 6.7 3 6.3 1.3 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 45.0 5 3 2 0.4 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 12.0 3 4 2 0.4 n/a n/a n/a n/a n/a n/a n/a n/a 6 Door 40.0 6.7 6 2 0.4 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 30.0 5 3 2 0.4 n/a n/a n/a n/a n/a n/a n/a n/a HVAC SYSTEMS Minimum Duct System Type Efficiency Location HOUSE Furnace 0.806 AFUE Attic Evaporative 11.00 SEER Attic Duct Duct R -value Efficiency R-4.2 0.830 R-4.2 0.810 COMPUTER METHOD SUMMARY Page 8 C -2R Project Title.......... Residence for Seegert Date........ 06/26/95 MICROPAS4 v4.02 File-SEEGERCO Wth-CTZ11S92 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas Standard 1 0.59 40 R-0 SPECIAL FEATURES/REMARKS R-4.2 duct insulation required R-19 floor insulation required per Form 3 R-15 wall insulation required per Form 3s R-38 ceiling insulation required per Form 3 Glazing U -values per MFR'S. NFRC testing & certification Viking or Milgard alum. frame dual -pane clear glazing req'd. FURN.806: RHEEM RGDG-075 w/0.806 AFUE @ 59,000 Btu/hr. output EVAP.11.0: 11.0 SEER w/ CEC MIN. REQ'TS. FOR EVAPORATIVE COOLING EVAP.11.0: 3.2 cfm / sq.ft. = 4013 cfm min. req'd. output EVAP.11.0: Provide ceil. vent'n. baffles & cont. ridge vent HWH: Rheemglas Fury 21VR40-7P CONSTRUCTION ASSEMBLY Page 9 3R Project Title.......... Residence for Seegert Date........ 06/26/95 MICROPAS4 v4.02 File-SEEGERCO Wth-CTZ11S92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference Name . SW.15.2X4.16 Description .... Wall R-15 2x4 16oc Type ........... Wall R -Value ........ 15 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16 inches on center Fraction ..... 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Name Description 0. FILM. EX Ex inter value 1. STUCCO.0.88 .87 in stucc 2. BLDG.PAPER Bui (felt) 3c. BATT.R15 R-15 batt insul (cavity = 3.5 in) 3f. FIR.2X4 2x4 in fir framing 4. GYP.0.50 0.50 in gypsum or plaster board I. FILM.IN.WLL Inside air film: heat sideways FRAMING ADJUSTMENT CALCULATION Cavity Total Unadjusted R -Values Framing Cavity Frame R -Value R -Value 0.17 0.17 0.17 0.17 0.06 0.06 15.00 -- -- 3.46 0.45 0.45 0.68 0.68 16.53 5.00 Total U -Value: (1 / 16.53 x 0.85) + (1 / 5.00'x 0.15) = 0.081 Btuh/sf-F Total R -Value: 1 / 0.081 = 12.28 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 10 3R Project Title.......... Residence for Seegert Date........ 06/26/95 MICROPAS4 v4.02 File-SEEGERCO Wth-CTZ11S92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference Name . GW.15.2X4.16 Description .... Wall R-15 2x4 16oc Type ........... Wall R -Value ........ 15 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16 inches on center Fraction ..... 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value 0. FILM.EX Exterior air film: winter value 0.17 0.17 1. GYP.0.63 0.625 in gypsum or plaster board 0.62 0.62 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. BATT.R15 R-15 batt insul (cavity = 3.5 in) 15.00 -- 3f. FIR.2X4 2x4 in fir framing -- 3.46 4. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values 16.98 5.44 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 16.98 x 0.85) + (1 / 5.44 x 0.15) = 0.078 Btuh/sf-F Total R -Value: 1 / 0.078 = 12.89 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 11 3R Project Title.......... Residence for Seegert Date........ 06/26/95 MICROPAS4 v4.02 File-SEEGERCO Wth-CTZ11S92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference.Name . R.38.2X6.16 Description Roof R-38 2x6 16oc Type ........... Roof R -Value 38 sf-F/Btuh Framing Material ..... FIR.2X6 Spacing ...... 16 inches on center Fraction ..... 0.10 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS n Material Cavity Frame Name Description R -Value R -Value O. FILM.EX Exterior air film: winter value 0.17 0.17 1. SHNGL.ASPHLT Asphault shingle roofing 0.44 0.44 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3. PLY.0.50 0.50 in plywood 0.62 0.62 4. AIR.RF.3.50 3.5 in & greater air space: heat flow up 0.80 0.80 " 5. BATT.RI9.0 R-19 batt insul (cavity > 5.5 in) 19.00 19.00 6c. BATT.RI9.0 R-19 batt insul (cavity > 5.5 in) 19.00 -- 6f. FIR.2X6 2x6 in fir framing -- 5.45 7. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.RF Inside air film: heat flow straight up 0.61 0.61 Total Unadjusted R -Values 41.15 27.60 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 41.15 x 0.90) + (1 / 27.60 x 0.10) = 0.025 Btuh/sf-F Total R -Value: 1 / 0.025 = 39.22 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 12 3R Project Title.......... Residence for Seegert Date........ 06/26/95 MICROPAS4 v4.02 File-SEEGERCO Wth-CTZ11S92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference Name . FC.19.2X6.16 Description .... Floor Crwl R-19 2x6 16oc Type ........... Floor R -Value ........ 19 sf-F/Btuh Framing Material ..... FIR.2X6 Spacing ...... 16 inches on center Fraction ..... 0.10 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Name Description 0. FILM.EX Exterior air film: winter value 1. CRAWLSPACE Effective R -value of vented crawlspace 2c. BATT.RI9.0 R-19 batt insul (cavity > 5.5 in) 2f. FIR.2X6 2x6 in fir framing 3. PLY.0.75 0.75 in plywood 4. CARPET Carpet & pad I. FILM.IN.FLR Inside air film: heat flow down FRAMING ADJUSTMENT CALCULATION' Cavity Total Unadjusted R -Values Framing Cavity R -Value 0.17 6.00 19.00 0.93 2.08 0.92 zy.IU Total U -Value: (1 / 29.10 x 0.90) + (1 / 15.55 x 0.10) = 0.037 Btuh/sf-F Total R -Value: 1 / 0.037 = 26.77 sf-F/Btuh Frame R -Value 0.17 6.00 5.45 0.93 2.08 0.92 15.55 HVAC SIZING Page 13 HVAC Project Title.......... Residence for Seegert Date........ 06/26/95 P t Add LOT #23 -r 11 %J A. ........ Vi age Oaks #2 Oroville Documentation Author... Neal Kuopus Company ................ CALCTECH Telephone .............. (916) 534-5066 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Check/ Date MICROPAS4 v4.02 File-SEEGERCO Wth-CTZllS92 Program -HVAC SIZING User#-MP1320 User-CALCTECH Run -Proposed Residence GENERAL INFORMATION FloorArea ................. Volume.. .................. Front Orientation.......... Sizing Location............ Latitude... .... ........ Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... SummerRange........ ..... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 1254 sf 10032 cf Front Facing OROVILLE RS 39.5 degrees 30 F 70 F 104 F 78 F 37 F No No No 0.20 HEATING AND COOLING LOAD SUMMARY Heating (Btuh) Opaque Conduction and Solar...... 8070 Glazing Conduction ............... 5452 Glazing Solar .................... n/a Infiltration ..................... 5706 InternalGain .................... n/a Ducts ............................ 1923 Sensible Load .................... 21151 Latent Load ...................... n/a Minimum Total Load 21151 142 deg (SE) Cooling (Btuh) 4167 3544 7535 2343 2100 1969 21657 4331 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. j CHRISTOPHER SEEGERT 6103 OLD OLIVE HWY OROVILLE, CA 95965 Eutte, co,, BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE. CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7541 FAX: (916) 538-2140 5/30/96 RE: Building Permit #95-1364 Expiration Date: 7/5/96 A.P. # 69-500-007 With reference to the above subject, our records indicate that your building permit expires on the above date and your permit falls into the category marked below: [X] Permit work started, but not completed. Permit may be renewed for 1/2 the original building permit fee (plus a $20.00 filing fee). The renewal permit will extend the building permit for an additional year from the original expiration date. Should you not renew your permit within 30 days of the expiration date, all work must cease until a new building permit has been issued. For your convenience, we are enclosing a renewal application form and owner -builder form -to be completed and signed by you where indicated and returned to this office together with the fee shown. Please return all copies of the application form. [ ] No inspections have been made on permit work. Inspections are required to verify code compliance. We are unable to renew a permit where the work has not been started and inspected prior to permit expiration. After expiration of your permit, no"work may be started until a new permit has been issued. If our records are in error or should you have any questions concerning this matter, please contact the OROVILLE office. Thank you for your prompt attention concerning this matter. Yours very truly, Michfael C. Vieira, C.B.O. MCV:ahb Manager, Building Inspection Attachments Chico Office - 1469 Humboldt Rd/891-2751