Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
069-540-015
69-54-15 1921-90 , P, E m a AZTEC Construction - 15 Osborne Ct., Orovil O (new single' family) . rr _ 6 f' 54-1'S Permit#1528-91B (open deck/sf) i A � r 069-540-015 •92-2333 BPE DUNCAN, Kevin c• Barbara 15 Osborne Ct;•,Oroville: contr: Polly Pools swimming pool 9_�y -4;- c�i I ani uo � � RESIDENTIAL 059-540-015 92-2333 BPE- DUNCAN, Kevin & Barbara 15 Osborne Ct, Oroville contr: Polly Pools swimming pool i d 5 T 1 JOB FINALE Signature 'J OK O = Not OK = Not Ageady ble �9 Noteady RESIDENTIAL (Single & Duplex) '= Date UNDERFLOOR (Plans) OK except ti's 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ P' Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel- Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit),OK except ti's 16. Water Htr.: Vent -Access -Combustion Air -Baffle ----------------- - ----------------------------- 17. Water Pipe; Test & Anchor -Nail Protection --------------- ------------------------------ 18. D.W.V.; Test -Fittings & Anchor -Nail Protection ----------------- ------------------ 19. Shower Pan; Test, First Floor -Tub Access ----------------- ------------------------------- 20. Test -Tub & --Shower.-Second Floor -Tub Access ---------------------------- - ----------------- 21. Gas Pipe: Size & Anchors ---------- ------------------------------------------------------------ Date Card B-1 Date Card B-1 ----------------------------------------------------------------------- Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except ti's 22. Fixture & Transformer Clearance -Ins. Protection ------------ - ----------- 23 Elec. Receptacles Spacing -Lights & Switches at Doors --------- ---- -------------------------------------- ------- 24. Size Boxes & No. of Conductors -Stapled -------- ------------------------------- ------ ---- 25. Romex Installed Close to Edge of Studs & C.J. - --- -------------------------------- 26. Equip Ground made up w!Mech. Fastners-Bond Gas & Water ------- -------------------------------------------------------------- 27. 2 Appliance Circuts in Kitchen & Conductor SizerGFI ------------------------------=------------------------- 28 Subfeed Wire Size ! ga. Cu or AI-A.C. Wire Size / ! ga. Cu or At --------------------------------- ------------------------------------------------ 29. --------------- - -- -- 29. Range Circ / r ga. Cu or AI -Oven Circ. / / ga. Cu or Al. Insulated Neutral ❑ Yes ❑ No -------------------- -------------------------------------------------- 30. Service -Riser Conductors & Ground -Main Disconnect ---------- ---------------------------------------------------------------- ------------ 31. Equip. Clearances-Panels-Motors-Mech. Equip. -------------------------------------------------------- 32. Clothes Closet Light -Shower Light -Spa Light ----------------------------------------------------------------------------------- 33. Smoke Detector ---------------------------------------------------------------------------------- Date Card B-1 Date Card B-1 -------------- ---------------------------------------------------------------- Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except P's 34. A.C. Ducts Insulation & Support --------------------------------------------------------------------------------- 35. Vent Fan: Exhaust above insulation -------------------------------------------------------------- 36. Condensate Drain & Overflow: Size & Grade -- ---- --------------------------- - -----....._.__. 37. Furnance-Vent: Access -Comb. Air -Return Air Vent -115 outlet -._..- ------------------------------------------- 38. Attic Access & Platform if Furnance in Attic ------------------------------------------------------------------------------------- Date Card B-1 Date Card B-1 -------------------------------------------------------------------------------- Date Card B-1 Date Card B-1 Date FRAMING (Plans) OK except h's 39. Sils. Proper Material & Anchors - --- ----------------------------------------------------------- - 40. Walls Studs -Nailing. Spacing & Bracing -Plates -Sound ----------- - --------------------------------------------------- 41 Bearing Walls over Girders & Floor Nailing - ---------------------------------------------------------- 42. Draft Stop in Walls (rat proof) - ---------------------- ----------------------- 43. Fire Stops Furred Ceilings -Stairs -Chases -Tub ---------------------------------- ----------------------------------- 44. Headers & Beam -Size & Bearing DateFRAMING (Continued) 4;. Hangers -Post Caps -Anchors -Connectors 46. Cing. Joist-Rftr. ties-Purlin-roof Brac-Truss-Shthng.-Rfng. 47. Fireplace Ties or Type A Flue -Fireplace Throat clearance 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles ------------- 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 50. Garage Fire Protection Framing 51. Property Line Firewall & Openings 52. Ext. Doors -One 3' -Check Garage -3rd Story, 2 Exits 53. Stairs; Width -Head room -Rise-Run-Landin Fire Protection ------------- 54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers ----- --- 55. Siding -Nailing Veneer 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 57. Glazing Area -Glass Protection -Skylights- Plastic 58. Shear Walls; Nailing -Bolts 59, Insulation -Walls -Ceilings 60. Infiltration -Walls -Windows - -- -------- ------------------- Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except ti's 61. Ext. Steps -Door & Sidelight Protection -Landings ----------------------- -- - 62. Smoke Detector ------------------------- - 63. Furnace: Vents -Clearance -Comb. Air -Connector - In Garage: Above Floor-Ducts-Mech. Protection --------------- 64. Bedroom Exiting ---------------------- 65. G F.I & Bath Fixtures & Tub Access -Spa 66. Elec. Trim & Subpanel; Breaker Sizes & Labels 67. Stairs & Rails 68. Fireplace or Stove: Clearances -Hearth ---------------- 69 Elec. Outlets at Wood Panel: Int. & Ext. --------...------------------------ --- 70. Kit.Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance 71. Elec. Outlets & Receptacles at Kit. Counter ------------------------ ---- 72. Garage Fire Door: Swing -Landing -Closer ------------------------------- -------------- - 73.--A.C.-Duct in -Garage -Damper - - 74. Wtr. Htr.: Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage: Above Floor-Mech. Protection ------------ ------------------------------ 75. Plb.. Elec. & Mech. Equip. Listed for Location ----------------------------------- 76. Elec. Receptacles in Garage: (G.F.I.)-Romex Protection ----------------- 77. Insulation -Foam -Looked in Attic ❑ Yes ---------------------------------- ------------- 78. Guard Rails & Deck Construction -Post Caps 79. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 80. Following instld.: Drive ❑ Yes ❑ No: Walks ❑ Yes ❑ No; Planters Cl Yes ❑ No ----------------------- 81. --------- ...-----------81. Stucco_Brown-Finish - ------ 82. A.C. Unit: Disconnect. Electrical, Plumbing - - - -- - ----- -- --- ------------------_-- 83. Vents Above Roof; Plb9Applia-nce--F-ire lace.-Cle-a- rance to Openings - - - - - 84. Water Well; Disconnect, Electrical, Plumbing -------------- -------------------------- -- - 85. Exterior Elec. Trim; G.F.I. Receptacle -Underground -- -- --------- ---------------- 86. Ventilation Throughout House ----------------------- 87. ---- -----------------87. Glass Protection ----------- -------------------- 88. Corrections from Previous Inspections 89. Gas Test -Meters Tagged; Gas -Electric _.._._..--- --------------------- 1-910 . Water & Sewer Connected -C/O to Grade -HD Approval 91. Energy Compliance Certificate -Other Certificates ------------------------------------ ------ ------------------------------------------- Date Card B-1 Date Card B-1 -- ----- --- - ---------------------- Date ---------------------Date Card B-1 Date Card B-1 --------------------------- Date -----------------------Date Card B-1 Date Card B-1 Comments at Final: J=OK ' 0 = Not OK = Not Applicable ' = Not Ready MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s ' 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/0 Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap: / f1 -ft. / /"Nat. or/ /"L"ft./ /"LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/0 to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PO S (Plans) OK except #'s il,11. Se cks-Easements Soi s; Compaction -Structure Stability Pool Structure; Steel -Connections -Thickness Deed Men -Lining �%*.00llec.; Receptacles and -4.4 k+' g, Distances-GFI ec.; PeeLLiWI3 D9; 15 volts-GFI Ele nclosures; Conduit Entries -Terminals -Listed leq-; Bonding; Metal w/5' -Circulating Equip. -Heater lec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. _ Boxes-Enclosures-Panelboards- Ins. to Main in Conduit 9.th Department Approval LIT Plumb.; Cir. Test -Water Supply Test Date j, Card 13-1 i Date Card B-1 Dat rd B-1 Date Card B-1 -'r �.. .: Yl�:--.... � _� :..t'��jy„v'a--.r3hL)�.sT..�,�q.Ry:.�."�:�1"`z._.is4j[j a — ... �. ,. r• ,� J COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE ER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. Date/ - Inspector 11/91 7� COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT PERMIT N� ASSESSOR PARCEL. NUMBER 069-540-015 ZONING R 1 I BUILDING PERMIT OWNER KEVIN & BARBARA DUNCAN TELEPHONE 589-5945 SQ. FT. OCC. BUILDING VALUATION CONTR OWNER'S MAILING ADDRESS 15 OSBORNE CT OROVILLE 95966 CONTRACTOR'S NAME POLLY POOLS TELEPHONE 673-6131 CONTRACTOR'S MAILING ADDRESS 1377 HUTCHINSON RD YUBA CITY 95993 Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation is r Filing Fee $ 15.00 LENDER'S MAILING ADDRESS Permit Fee $ 120.00 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 20.00 Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS 15 OSBORNE CTOROVILLE Permit fee $ 155.00 PLUMBING PERMIT Filing Fee 15.00 Each Trap 5.00 Solar or heat pump water heater 20.00 LOT NO. 15 SUBDIVISION NAME KRE UNIT 8 PARCEL MAP Water piping 7.00 7.00 Each qas water heater or vent 7.00 USE OF STRUCTURE SF ❑ Duplex[] Mobilehome❑ Other POOL SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 15.00 Mobile Home S I G I W 615.001 TYPE OF WORK New® Addition [I Remodel n Utilities 0 Installation❑ Other ❑ Describe work: MASTER #/%��'� _ Permit Fee $ 22.00 Contractor ELECTRICAL PERMIT FiIingFee 15.00 Main service 2000AA 0OR LESS 2OR LESS 18.50 Main service 200A TO 1000A1 37.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Buslnes$ and Professions Code and my license is in full force and effect. License No. t 3 i 4 Classification e 3 Fl 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST.( DWELLING OCCUP.gd\ OR ADONS, l ACC. SLOGS. // 3.64sq.ft. NEW CONSTR. MULTI -OUTLET NON.RESID BRANCH CIRC ITS ^ 5 00 POWER APPARATUS & (SINGLE OUTLET CIR. Ex, OCCUp�OUTLETS OR FIXTURES 20 76 FIXED APPLNS Ex. Occup. OUTLETS (RESID )REA.) 3.00 Temporary service 15.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ 30. — WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. Ugoe-1 have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT FiIingFee 15.00 Heating Cooling Hood 6.50 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against aid Cou ty in consequence o he granting of this permit. X ,. Date Si nature of Applicant - Owner ®' ❑ g pp ❑ Contractor Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee S Energy Inspection Fee $ occ CONST TYPE TOTAL FEE $ 207.00 HAz DFEES I PARCEL I PD I HD ISSU This permit is hereby issued under sions of the Butt County Code and/or work d'c ted a o e for which fees IR OF PUBLIC By PERM EXPIRES Date the applicable provi- resolutions to do have been paid. WORKS Date? 14 Receipt No. 117119 WHITE-O.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT 6w+...�R"'�[°f'9►�tiT1*P'r[�#7!,^snVz7i�R��'+WI/R'f� "COUNTY OF BUTTE - DEPART NT OF PUBLIC WORKS - BUILDING DIVISION , -lo a, 7 COUNTY CENTER DRIVE - OROVILLE, LIFORNIA 95965 - TELEPHONE (916) 538-7541 L,e:^CA. 4�I �.. PERMIT APPLICATION DATA SHEET j OWNER /�-' V ► h Proposed Building Use � ,�j PP No. �o l cc - S Biiildin� Inspector . CJS) Date o� :* At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED BY 1. All items have been submitted . ......................... ............... . } 2. Plot plans, 3/4 sets, signed by preparer of plans. 3. Complete plans, 3/4 sets, signed by preparer of plans . ...................... 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............. 5. Hazardous Material Form . ............................................. 6. Energy Design Compliance and supporting documentation . ................... 7. Statement of Intent for Non -Heated and A/C Buildings . ...................... ' 8. Engineered truss details and layout in duplicate (required prior to plan check). ... . 9. Mobilehome data and manufacturer's installation instructions, 2 sets. ........... - 10. Fees of$ . .........................................------------ M 11. Impact fees as shown on attached schedule . .............................. 12. California Department of Forestry plan approval/fees: 13. Flood elevation letter (100 year flood) Vali nia Engineer ................... 14. Sanitation and plot plan approval �.Ol� Health Department . ............. 15. City of Chico plumbing permit. ...................:.................... . 16. Plot plan and business license approval from City of Biggs/Gridley. ............ . 17. Planning approval for (A) Use: (B) Parking: . ........ 18. Contact Land Development about (A) Improvements (B) Drainage. .......... . 19. Driveway permit (construction approval* required prior to occupancy). ... . Pre-lnspedion request 20. Pre -inspection for required. . to Building Inspector (Date) ontractor's license information. (No., Name Style, Classification). .............. ? 9� 22. Certificate of Workmans Compensation Insurance . ........................ Owner -Builder Verification (Given to owner , Mail to owner _)............. 24. Recorded copy of Agricultural Acknowledgement Statement . ................. . 25. Letter of signature authorization . ........................................ 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. ..... 27. Letter of intent on building use . ........................................ . 28. Mobilehome•utility clearance . .......................................... . 29. Documentation of legal access . ....................................... . 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... 31. - xisting violations/expired permits . ...................................... Plan check list. .... . 15S n e /j'o. l� Wh,en/ you issue the perm t, process as follows: Mail too nerl Mail to contractor. -1 Telephone lv 0- .and hold for pickup at d. office. Deliver with inspector. Other (� EG Parcel Creation ' Acreage Applicant Date 7- Z �'- Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Dep Copy of plans sent Health Dept. Fire t. Other Date By The following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data by _ phone _ mail ,1/ Counte 'NWDate ' Contractor, designer, owner, was advised of above required data,by _ phone _ mail t ou r by _ Date Plans checked by Date '"Plans approved by Date Sets of plans on hold in File cabinet AP folder Copy - Department of Public Works tj9A NO COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive- Oroville, California 95965 - Telephone: 916:'538-7541 APPLICATION AND PERMIT ASSESSOR PARCEL NMBSa % Z""'' G I BUILDING PERMIT OWN R 46a(a JA ' „� TELEPHONE SO.FT.OCC. BUILDING�dVAL UATION'379S945 I OWNER'SMA ADDRESS 9�� v 9S- s . CON OA[OR'S f E jgPH / CO,NTR C/ OR'S MAILIG ADDRESS � 1133 j Fireplace CONSTRUCTION LENDER UNKNO'WA Total Valuation $ Filing Fee $ 15.00 LENDER'S MAILING ADDRESS Permit Fee $ j' . QD ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ .70 00 Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADD ss © n f Permit fee $ VS00 PLUMBING PERMIT Filing Fee 15.00 Each Trap 5.00 Solar or heat pump water heater 20.00 LOT NO. S SUBDIVISI/QNNAME rN, 1 K /lvJ? PARCEL MAP Water piping 7.00 ��Q Each qas water heater or vent 7.00 USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome❑ Other /0,0 SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 15.00 Mobile Home S I G I W 1 15.00 TYPE OF WORK New x Addition ❑ Re,m,�} del ❑ Utilities Installation[] Other ❑ Describe work: /�/C/S tip r Permit Fee $ Contractor ELECTRICAL PERMIT FilingFee 15.00 Main seryice 600V OR LESS 200A OR LESS 18.50 Main service 200A TO IOOOA) 37.50 CONTRACTORS LICENSE LAW I declare under penalty ur ), p y of perjury y (Check One ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification Flt, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. ( DWELLING OCCUPM OR ACDNS. 1 ACC. BLDGS. // 3.54 sq.ft. NEW RESI0. BRANCH NON.R ESI D. BRANCH CIRC ITS @ 5.00 POWER APPARATUS e SINGLE OUTLET cIR. / Ex. OCCUp\OUTLETS OR FIXTURES 20 76d Ex. OCCUp. OUTLETS (FIXED PRESID )LNS REA.) I 3.00 Temporary service 15.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 /,$ 6)D Permit Fee $IL Q Contractor — WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 15.00 Heating Cooling Hood 6.50 Ventilation penult Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date Si nature of Applicant - owner g pp ❑ Contractor ❑ p and ❑ An OSHA permit is required for excavations over 5'0” deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST TYPE TOTAL FEES Q L90I HAz 1 0FEE5 I IMP I FLo 0 I CDF I PARCEL I PD HD I ISSUE This permit is hereby issue under the sions of the Butte County Code and/or work indicated above for which fees DIRECTOR OF PUBLIC By PERMIT EXPIRES Date applicable provi- resolutions to do have been paid. WORKS Date n�2 2 Receipt No. �_ 1 J WHITE-D.P.W.. TALLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT v [UP CHORD 2X4 FIR—LARCH 01 BOT CHORD 2X4 FIR—LARCH 01 WEBS 2X4 FIR—LARCH STANDARD CONNECTOR PLATES MUST BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF I.C.B.O. RESEARCH REPORT #2949. ALL PLATES ARE TO BE CENTERED ON THE JOINT, LEFT TO RIGHT AND TOP TO BOTTOM, EXCEPT WHEN LOCATED BY CIRCLE OR DIMENSION. SEE DRAWING 130 FOR "PLATE LOCATIONS ON TYPICAL JOINTS." 4X4 T TC X—LOC L—R: 0.29 4.15 7.65 11.14 15.00 BC X—LOC L—R: 0.29 7.65 15.00 SINGLE CUT WEB #—TC: 1.3 BC:2 (U) BOTTOM CHORD CHECKED FOR 10 PSF LIVE LOAD. CONNECTOR PLATES DESIGNED FOR GREEN LUMBER PER NOS TABLE 8.18. R-6330 W- 3.50' 7-7-12 17-7-12 15-3-8 OVER 2 SUPPORTS TYP.-ALPINE SEON-- 61252 FURNISH A COPY OF THIS DESIGN TO ERECTIC le 0 0 0 0 0 0 **IMPORTANT** 'L NOT BE Fol IAmy WARNING Do plucum E WILIZAE ECr� SND A.c= DEVIATION FROM THM EPECIFICATIOA OI ANY DEVIATION FPDN OWtCING.GEE 'BNT-701. ORCINS N� rAUSMS: INTO DESIGN ON ANY FAILURE TO GUILD -THE TWIGS IN CONFO MANCE CDNNENTARV AND f6CaPppATIO S-ATPII. SEE WITH THE 'DUALITY STANDARD GSTGI' BY TPI. ALPINE COIEC. THIS DESIGN FOR AWITIOiAL SPECIAL PENIA - ARE MANUFACTURED FROM 20 CAU[E GALVANIZED STEER W,EGG NEWT GRACING IEWIREMEMS. LKESS OTNEWOM OHIAIISE SHOW MEETING REO IEMENTS OP AWN AMB GRACE A. SROM TDP CLOD SHALL BE LATERALLY BRACED APPLY CM*CTOI9 TO OOT" PACES AT EACN .DINT AND LOCATE AS WITH PIDPEMY ATTACHEO PLVWOOO SEATHIMA NG MIDTHS ARE KAL UNLESS IAIQARO$ COiOMA•WITNi APPLICABLE PROVISIONS OF ASTTOM 6PECI m�01 A1010TH CEILING DID NOT U[�8 THImS S B AIDS ANO NTPI (PCT). OE'SIZN WITMFIRE RETARDANT TFUTED,LL Ftp. l.'7 •--TPI - TNUSS PLATE INSTIME ND_4 - NATTduL W9If.Ri 9tlF.CrerCi rirru cro wvrr rr"otu r•trnu )rn -r- I R-5150 W- 3.50' &CTOR REV 15.1.2 SCALE s DESIGN CRIT: UBC AEF R5Z TC LL 20.0 PSF DATE 11 TC OL 10.0 PSF DRWG CAUSE CA BC OL (U) 5.0 PSF CA—ENG Ag ITOT-LD. 35.0 PSF 0/A LEN. DUR.FAC. 1.25 PITCH SPACING 24.0" TYPE CC 3-8 A D C N D 0 W N 0) cD w 0) 0 N m TOP CHORD 2X4 FIR -LARCH #1 BOT CHORD 2X4 FIR -LARCH #li WEBS 2X4 FIR -LARCH STANDARD CONNECTOR PLATES MUST BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF I.C.B.O. RESEARCH REPORT 12949. ALL PLATES ARE TO BE CENTERED ON THE JOINT. LEFT TO RIGHT AND TDP TO BOTTOM. EXCEPT WHEN LOCATED BY CIRCLE OR DIMENSION. SEE DRAWING 130 FOR "PLATE LOCATIONS ON TYPICAL JOINTS. - WE TC X -LOC L -R: 0.29 5.32 10.00 14.58 19.71 0 BC X -LOC L -R: 0.29 10.00 19.71 D C SINGLE CUT WEB #-TC: i. 3 BC: 2 D N (U) BOTTOM CHORD CHECKED FOR 10 PSF LIVE LOAD. W N CONNECTOR PLATES DESIGNED FOR GREEN LUMBER PER NDS 0) TABLE 8.1B. W T+ Q) Q N V -10-3 R-7980 W— 3.50' gra. 0-0 OVER 2 SUPPOR 'LT. TYP.-ALPINE SEGN-- 61219 * FURNISH A COPY OF THIS DESIGN TO ERECTIC EXTREME Cum 0 0 0 0 0 0 *IMPORTANT** 9= Z � Fl "my' WARNING D-KUCUNL Becriam me CAC.=CM DEYtATIDN FROM THESE SPECIFICATIONS W ANY DEVIATION FROM SRACIRS.SEE '80T-70'. WMCINE NOW TTHLSSES C THIS DESIGN OR AMI FAZLURE 70 SUMO THE TRUM IM COFONAM7E CW@NTIW AW fEC0.amnaIS-.RPI) . on C WITM THE •ORALITY S7MOARO MSG* BT TPI. ALPINE COIECTOiB THIS CESISN FOR AWITIOAL SPECIAL Pmw- CME MYOFACTU EO FROM 20 GAUGE GALVANIZED STEEL LOLM NEWT SWINg REO VEWNTS. LMESS oTHERHNIBE C OTNERMISE SHO L WEETIMS REQUIREMENTS OF ASTM AMS GRACE A. SHOW TTP *MAD SKU.L 80 LATERALLY BRACEDt=APPLY COECTCRS TO BOTH FACES AT EACH JOINT AND LOCATE AS WITN PROPEFLY ATTACHED PLYWOOD SHEATNIla SH M. BEARING WIOTHS ARE A' NO IVAL UNLESS OTHERWISE 90W. BOTTOM CHOW WITH RIGID CEILING 0R BRACING OEGIOR STAIOAR09 t:ONFORM WITH APPLICABLE PIOVISIOAS OF AS SPECIFI® 01 DESIGN. m NOT USE THIS .NOSAIO ■TPI (PCT). DESIGN WITH FIRE RETMOANT TREATED UNSER. `•� �� C.z L C FH9I - TALIRS PLATE IM4Tt Tt]79 NftV MlT Ttfwil ti4Ttw <ac�TCTnl TTru e� .rw. nnu-.v. wrTnr R-6801 W- 3.50' DESIGN CRIT: UBC REF A TC LL 20.0 PSF DATE 1 TC OL 10.0 PSF ORWG CAU CA BC DL (U) 5.0 PSF CArENG TOT.LO. 35.0 PSF 0/A LEN. OUR. FAC. 1.25 PITCH SPACING _" � ��24 :0" TVOF C a U.J/oU 532--4794 1/14/89R5r S32 8931801 uj C 20-0-0 5.0/121 N!A, -- TOP CHORD 2X4 FIR—LARCH #i BOT CHORD 2X4 FIR—LARCH #1 WEBS 2X4 FIR—LARCH STANDARD CONNECTOR PLATES MUST BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF I.C.B.O. RESEARCH REPORT #2949. ALL PLATES ARE TO BE CENTERED ON THE JOINT, LEFT TO RIGHT AND TOP TO BOTTOM, EXCEPT WHEN LOCATED BY CIRCLE OR DIMENSION. SEE DRAWING .130 FOR "PLATE LOCATIONS ON TYPICAL JOINTS." 4X4 TC X—LOC L—R: 0.29 5.55 12.65 18.54 25.00 BC X—LOC L—R: 0.29 8.65 16.64 25.00 SINGLE CUT WEB 0—TC: 1, 4 (U) BOTTOM CHORD CHECKED FOR 10 PSF LIVE LOAD. CONNECTOR PLATES DESIGNED FOR GREEN LUMBER PER NOS TABLE 8.18. 1-10-3 iP-7-4a 147-7-47 a raj 9 rn LW3 --r 3 `• 25-3-8 OVER 2 SUPPORTS sol R-784/ W- 3.50' R-6924 4t- 3.50" PLT. TYP.—ALPINE SEaN-- 61239 x FURNISH A COPY OF THIS DESIGN TO ERECTION CONTRACTOR REV 15.1.2 SCALE m 0.2500 0 0 0 0 0 o ai4iIMPOFiTANT** �auu eor mnamix t,�wr WARNING uirwat�ws��ERECTION Iwo DESIGN CRIT: UBC QEF R532--47968 0 0 0 0 oevUnow coon ,wssc svEerFrurroe an "^ °Errtrtaw FIOw entclie.sEe •ever -re•, ointette wood riarsss& TC LL 16.0 PSF DATE 11/14/89 0 0 0 ' rwre ossrew a twr FAILIIiE to eutLo THE rouse IN cawr:anw►tE onr�wrtnr NO�EeowBOAttwa-.Tnrl . M0 0 o rtTw. THE "QUALITY srtwotao 0088* e. TR. ALPINE CONNECTORSTHIS oEstew F01 ADDITIONALsvEertL aEnu- TC DL 7. O PSF DQWG CAlJSR532 88318024 o EO O AM wtwistcTuaEo FROM 20 �u11BE etLrMiZEe BrG6L UILlSe NEWBwtCIf6 fEalriF7iBlle. VILEiie OTIEMreE ALPI o ot►rfatse swout wEETtwo fEOUIRE1QITa a terve tMWADE oE A. swrt tav CHORDewtLL BE uTERtLIr eAtCEO CA BC DL (U) 5.O PSF CA—ENG W tFa.r co�Ecraas to eorw rtoEs AT eta ,ronrt AND LOCATE is WITH wcFeiLr •tttcweo Fr.rwooD swEtTwrwq TRtJS$SHOW.TOT .LD. 28 . O PSF 0/A LEN, 25-3-8swo. eEtMr6 OWING ARE 4• NOMINAL UNLESSuEss OTHERWISE swow. eortow aao rove Rim Igatwe on eructwe o oEstew s,twotaos oorsaww WITH t00licta.E vworisrows OF AS sFEcirrEo ON aEzttew. ao NOT USE. THIS OUR. FAC . 1.25 PIT C H 5.0/-12 siO9 AND wTPi (PCT). DESIGN WITH FIRE ilTAFOtNT TREATED LUBEN. O O O O o O N --TPI � TR139 PLAiE IwsIITUiE. NOS - NATIO/ML LcsIC:.s7ESIFICATrow POA-wOsO Co+sruwcTlox SPACING 24.O7.____ T,YPE-•= ,CONN -- _J06: 12478 AZTEC LOT # 59 THIS DWG. PREPARED FROI TOP CHORD 2X4 FIR -LARCH #1 BOT CHORD 2X4 FIR -LARCH M1 WEBS 2X4 FIR -LARCH STANDARD CONNECTOR PLATES MUST BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF I.C.B.O. RESEARCH REPORT #2949. ALL PLATES ARE TO BE CENTERED ON THE JOINT. LEFT TO RIGHT AND TOP TO BOTTOM, EXCEPT WHEN LOCATED BY CIRCLE OR DIMENSION. SEE DRAWING 13O..FOR "PLATE LOCATIONS ON TYPICAL JOINTS." CONNECTOR PLATES OESIGNED FOR GREEN LUMBER PER NDS TABLE B.IB. 5X5 6.00 2X7. _ 1.5X3 2.0.01, c TC X -LOC L -R: 0.29 9.27 18.00 25.73 35.71 BC X -LOC L -R: 0•.29 9.27 18.00 26.73 35.71 SINGLE CUT WEB #-BC: 3 :2 ENDS: i. 5 (U) BOTTOM CHORD CHECKED FOR 10 PSF LIVE LOAD. (A)iX4 #3 HEM -FIR OR BETTER CONTINUOUS LATERAL BRACING TO BE EQUALLY SPACED. ATTACH WITH (2) Bd NAILS. BRACING MATERIAL TO BE SUPPLIED AND ATTACHED AT BOTH ENDS TO A SUITABLE SUPPORT BY ERECTION CONTRACTOR. 5X5 e.00 5X5 (A) 5X8 18-0-0_x_1 B-0-0 -0 OVER 2 SUPPORTS 1.5X3 �o p �kOcEss/o� ��QvAN> V. m m m # C22982 -r7,n EXP1 N. 2131193 -Ar H 2X7 0 D C N N W N 0) (D W 0) O N N R-1092# W- 3.50" R-992# W- 3.50' PLT. TYP.—ALPINE SEAN-- 61235 FURNISH A COPY OF THIS DESIGN TO ERECTION CONTRACTOR REV 15.1.2 SCALE — 0.1875 0 0 0 0 0 0 C C C C C G C C C C C C C C G C C ALPI OO �• C TRUSS C C C o o C C= ALPINE **IMPORTANT** SH&LL On Mme � INC., DEVIATION FNORW THEM SPECIFICATIONS OR ANY DEVIATION FROM EB THIS OION ON AM FAILURETO BUILD THE Tf1W188 IN CONFORMANCE WITH THE •GUIITT SUMARD 09186. 61 T4. ALPINE CCN ECTORS ARB MANUFACTURED FNWBWH a0 SAM GALVANIZED STEEL UNLESS OTHERWISE SHOWN, NEETING REOTIREMENTS OF DE ASTN Aub GRAA. APPLY COWFICTONS TO BOIN FACES AT EACH JOINT AND LOCATE AS SNON. SEARING WIDTHS ARE d' WOWHINILL (KESS Ol/ENMIse 51OMN. DESIGN 9TMOARDS CONsOrM WITH APPLICABLE PIWVISION3 ac LND9 ANO NTPI (PCT). WARNING w HP-40UHM ERECTION AM GRACINO.SED 'Mr -715. QiMCLs YOm TRUSS . COMMENTARY Ate IECpAtTgi►TIQ16-wTF31 - 6E[ THIS DESIGN FOR ADOITIOML SPECIAL PERIA- HENT OUCDO REEDDTWPBNTS. UNLESS OtIFJIWIBE SHOWN, TOP CHOW SHALL BE LATERALLY BRACED WITH PMOPER.T ATTACHED WLVWDOO SHEATNIN6, BOTTOM CHOW WITH RIGID CEILING OR BRACINS A9 SPECIFIED ON OESIOI. GONOT USE THIS DESIGN WITH FINE FETARWANY TREATED LU UM. CA __-,.> DESIGN CRIT: UBC UBC REF 8532--47964 TC LL 1V . 0 PSF TC DL 7.0 PSF BC OL (U) 5.0 PSF TOT.LD. 28 . O PSF DATE 11/14/89 DRWG CAUSM32 MIS022 CA -ENG In O/A NEN. 36-0-0 DUR.FaC. 1 .25 PITCH 6.0 12 ■»TPI - TI PLATE INSTITUTE. HO3.—NATIONAL DESIGN SPECIFICATION .FOR. WOW CONSTRUCTION—- -. A T r w SPACING, -.:x.:;-24..0... TYPE _.COMN-,- .-..�..� .. •7uD. le4Cv A I tG LU11 V M1 I M 5 UWU . YHt:PAH U F H M TOP CHORD 2X4 FIR -LARCH #1 BOT CHORD 2X4 FIR -LARCH 111 WEBS 2X4 FIR -LARCH STANDARD CONNECTOR PLATES MUST BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF I.C.B.O. RESEARCH REPORT 12949. ALL PLATES ARE TO BE CENTERED ON THE JOINT. LEFT TO RIGHT AND TOP TO BOTTOM, EXCEPT WHEN LOCATED BY CIRCLE OR DIMENSION. SEE DRAWING 130 FOR "PLATE LOCATIONS ON TYPICAL JOINTS." ALL TOP CHORD SPLICES OCCURRING BETWEEN PANEL POINTS ARE TO BE LOCATED AT APPROXIMATELY i/4 OF PANEL LENGTH FROM PANEL POINT (WITHIN 12") AND SHOULD NOT OCCUR IN PANELS NEXT TO A PANEL POINT SPLICE. Note: Special handling care should be taken during shipping and erection of trusses. See "warning" note below. (B) See drawing A115/E for filler detail. I 5X5 3X4 6.0 OF IX7 11 '1.5X3 TC X -LOC L -R: 0.29 5.93 11.17 18.00 23.35 29.51 35.71 A BC X -LOC L -R: 0.29 5.93 11.30 18.00 29.51 29.51 35.71 C SINGLE CUT WEB #-BC: 5 ;2 ENDS: 1. 3. 7. 9 N (U) BOTTOM CHORD CHECKED FOR 10 PSF LIV8 LOAD. W N (A) iX4 193 HEM -FIR OR BETTER CONTINUOUS LATERAL BRACING TO CD BE EQUALLY SPACED. ATTACH WITH (2) 8d NAILS. BRACING (0 MATERIAL TO BE SUPPLIED AND ATTACHED AT BOTH ENDS TO A W SUITABLE SUPPORT BY ERECTION CONTRACTOR. r• CD CONNECTOR PLATES DESIGNED FOR GREEN LUMBER PER NOS 0 TABLE 8.18. 0 N 5X5 3X6 X8 3X4 6.00 3X9 (A);>5X6 5X 10 (B) v 2X4 F.L. #1 18-0-0_18-0-0 11-3-12-1--12-2-6 7 12-5-14 36-0-0 OVER 2 SUPPORTS 1.5X3 9-0-0 3X6 2-0-0 ?f D`Essof0 f> � z m e? r, E^'• ��;3ii�3 Ln'A R-992# W- 3.50" R-10920 W- 3.50' PLT. TYP.-ALPINE SEAN-- 61152 FURNISH A COPY OF THIS DESIGN TO ERECTION CONTRACTOR REV 15.1.2 SCALE - 0.1875 Q Q Q Q Q Q ATRUSS CM Q PROCUUM **IMPORTANT** =u DoT xsvarsm Iain DEVIATION FROM TNESE SPECIFICATIONS ON AMY WVIATIDN FIWN THIS DESIGN ON ANY FAILURE TO BUILD TM TIMIBS IN CO CA M ICE VITH THE "OWLITY STANDATD GMSB" BY TPI. ALPINE CONECTORS ARS MAKFACTURED FROM 20 SAUCE GALVANIZED STEM LN JM OTHMISE SHOW mr.13M REBUIREMDYTS OF ASTN AAA5 GRADE A. CONECTONS TO SM FACES AT EACN JOINT AND LOCATE AS SNOW.BEARMS MIOTM ARE d' NOMINAL UNLEW OYMU MISE SHDW. STANOMOS CO FOW WITH APPLICABLE PROVISIONS OF *MDs AND NTPI (PC71. um WARNING n1i I IPM VISCI `AM BRACIM.SEE '80T -7e", SMLACIN7 'W= Mang! CCHNNTARY ANO IECOIA@OATIONS-*TPI). SEE TMS DESIGN FOR AWTTIONAL SPECIAL. PEFM- PMW BRACDIS REWUND 6NTS. UNLESS OTENNI E SHOW TDP CHGO SHALL BE LATERALLY BRACED VITN PNDIER.Y ATTACM0 PLYWm SWATHING.TOT. BDTTON 0*16 MITH RIGID C -INSORBRACING.DESIGN AS SPECIFIED CN DESIGN. W NIT ISE TNIS OESIGN WITH FIRE FETAROANT TREATED LIMBER. CA . _..-....,-. _SP.AC1NG DESIGN CRIT: UBC REF 8532--47874 C C LL 16 . O PSF TC OL 7. O PSF BC OL (U) 5 • 0 PSF LD. 28. O PSF DATE 11/14/89 DRWG. CAUSASW MIN02 CA—ENG ILIIAPPLY 0/A LEN. 35-0-0 DUR . F AC. 1.25 *-_TPI -. TAM PLATE INSTITUTE N09.?.NATIpYi L+�4IQ^.9 CIi.ICA7I6'd.F^.4 waD cGeTHL�sTtDx. _._..,..�......,. - _6,24. 0" _.. TYPEw- SPEC-- ... r- C`n CD TOP CHORD 2X4 FIR -LARCH #1 TC X -LOC L -R: 0.29 5.93 11.17 18.00 23.35 29.51 35.71 A BOT CHORD 2X4 FIR -LARCH #1 ' y WEBS 2X4 FIR -LARCH STANDARD BC X -LOC L -R: 0.29 5.93 11.30 18.00 23.51 29.51 35.71 C PLT. TYP.-ALPINE N CONNECTOR PLATES MUST BE INSTALLED IN ACCORDANCE WITH SINGLE CUT WEB #-BC: 5 :2 ENDS: 1. 3, 7. 9 m REQUIREMENTS OF I.C.B.O. RESEARCH REPORT #2949. **IMPORTANT*X SN�IALI"END g�aESPOMEDLE FON I NY DEVIATION FRO{ TIES[ SPECIFICATIONS OR ANY DEVIATION P=M WARNING >M�i UG�IIM& O*CrAmsm �IOM CARS AND BRACING.S R 'WT -70*. MfthCtNS NOW Trams (U) BOTTOM CHORD CHECKED FOR 10 PSF LIVE LOAD. W ALL PLATES ARE TO BE CENTERED ON THE JOINT. LEFT TO RIGHT AND DATE 11/14/89 N TOP TO BOTTOM, EXCEPT WHEN LOCATED BY CIRCLE OR DIMENSION. (A)1X4 #3 HEM -FIR OR BETTER CONTINUOUS LATERAL BRACING TO 0) SEE DRAWING 130 FOR "PLATE LOCATIONS ON TYPICAL JOINTS." BE EQUALLY SPACED. ATTACH WITH (2) 8d NAILS. BRACING �p DRWG CAU6R592 98318029 MATERIAL TO BE SUPPLIED AND ATTACHED AT BOTH ENDS TO A (P) ALL TOP CHORD SPLICES OCCURRING BETWEEN SUITABLE SUPPORT BY ERECTION CONTRACTOR. PANEL POINTS ARE TO BE LOCATED AT APPROXIMATELY C= --C= C AMOS ANO MTPI (PCT). 114 OF PANEL LENGTH FROM PANEL POINT (WITHIN 12") AND CONNECTOR PLATES DESIGNED FOR GREEN LUMBER PER NDS SHOULD NOT OCCUR IN PANELS NEXT TO A PANEL POINT SPLICE. TABLE 8.0. N m 3X4 6.0� 5X5 18-0-0 116-0-0 3X6 12 3X4 6.00 2-0 11-3-12-1-12-2-6 112-5-14 36-0-0 OVER 2 SUPPORTS R-992# W- 3.50" R-1092# W- 3.50' PLT. TYP.-ALPINE SEAN-- 61253 FURNISH A COPY OF THIS DESIGN TO ERECTION CONTRACTOR REV 15.1.2 SCALE a 0.1875 0 0 0 0 0 0 0 0 0 0 **IMPORTANT*X SN�IALI"END g�aESPOMEDLE FON I NY DEVIATION FRO{ TIES[ SPECIFICATIONS OR ANY DEVIATION P=M WARNING >M�i UG�IIM& O*CrAmsm �IOM CARS AND BRACING.S R 'WT -70*. MfthCtNS NOW Trams DESIGN CRIT: UBC REF 8532--4798 TC LL 16.0 PSF DATE 11/14/89 C 0 o C= o o 0 o 0 o o LPI o o o TRU55 0 THIe OGIGN ON ANY FAILURE TO MILO THE TAWS IN COiOMAN E WITH THE 'QUALITY STANDAM OWES* BY TPI. ALPINE COMECTDRB AM NAMPACTUED FROM 20 BMW GALVANIZED STEEL UNLESS ,OTHERIISE SML MUTING fEOVIFOVaS OF ASM AMB SPADE A. "O AMYCOMECTO S To WIN FACES AT EACH ADR AND LOCATE AS SHOWN. GEARING WIDTHS ARE A' NOMINAL U LeM 07M MISE SHOWN. DESIGNSTANDARDS COFOM WITH APPLICABLE PWVISIOIS OF CWIENTAFFT NO RMOMME OATIOW-"TKI . WE THIS DESIGN FOR ADDITIONAL SPECIAL PEAMA- NERT BIACDNS IEAITiEMENTa. UNLESS OTW MM SHOW aTOP aaPo SNALL BE LATERAUY SPACED WITH PNIXEPLV ATTACHED PLYWOOD SIEATNINO. BOTTOM CHO D WIT" RIGID CEILING OR ORACTNG AS SPECIFIED ON DESIGN. DD Mar USE THIS CA TC DL 7.0 // \\ BCOL `U/ 5.0 TOT. LD. 28.0 PSF PSF PSF DRWG CAU6R592 98318029 CA -ENG 0/A LEN. 36-0-0 OUR. FAC. 1.25 '^C7 •o...`o.. C= --C= C AMOS ANO MTPI (PCT). DESIGN MIM PIKE RETIJaANT TTATED UMBER. •..�....._;..i,r,......�.. .•. ■—TPI = TOMPLATE IN97I7UT MOS NATIONAL OEHIfiiN SPECIFICATION FOR MOOD CO6TAUCTIGN �+ SPACING 24 . QM"_".`": _ c T YPE�7PEC--�.,Y.~n�. •� IUP CHORD 2X4 FIR -LARCH #1 BOT CHORD 2X4 FIR -LARCH 01 WEBS 2X4 FIR -LARCH STANDARD CONNECTOR PLATES MUST BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF I.C.B.O. RESEARCH REPORT #2949. ALL PLATES ARE TO BE CENTERED ON THE JOINT, LEFT TO RIGHT AND TOP TO BOTTOM, EXCEPT WHEN LOCATED BY CIRCLE OR DIMENSION. SEE DRAWING 130 FOR "PLATE LOCATIONS ON TYPICAL JOINTS." ALL TOP CHORD SPLICES OCCURRING BETWEEN PANEL POINTS ARE TO BE LOCATED AT APPROXIMATELY' 1/4 OF PANEL LENGTH FROM PANEL POINT (WITHIN 12") AND SHOULD NOT OCCUR IN PANELS NEXT TO A PANEL POINT SPLICE. See drawing A115/E for filler detail. 5X5 0 TC X -LOC L -R: 0.29 9.27 18.00 23.00 27.19 31.17 35.71 0 BC X -LOC L -R: 0.29 9.27 18.63 27.18 31.17 35.71 D C SINGLE CUT WEB #-BC: 3 ;2 ENDS: 1. 6, 8 CA (U) BOTTOM CHORD CHECKED FOR 10 PSF LIVE LOAD. W Pi (A)iX4 #3 HEM -FIR OR BETTER CONTINUOUS LATERAL BRACING TO 07 BE EQUALLY SPACED. ATTACH WITH (2) Bd NAILS. BRACING (0 MATERIAL TO BE SUPPLIED AND ATTACHED AT BOTH ENDS TO A W SUITABLE SUPPORT BY ERECTION CONTRACTOR. N N+ CONNECTOR PLATES DESIGNED FOR GREEN LUMBER PER NDS 0 TABLE 8.18. N 0 `2 � m M C2 X23 m o•? -. I _j✓�1i93 � i 1 5.00 6.00 A) 2X7 3.00C� 3X7 12 '~ 1.5X3 1.5X3 5X12 7X8 r _ 18-7-12 5-8-b 2-0-0 18-0-0 18-0-0 18-7-12 8-6-6 8-9-14 - 36-0-0 OVER 2 SUPPORTS R-1092# W- 3.50" R-992# W- 3.50' PLT. TYP.-ALPINE SEQN-- 61781 FURNISH A COPY OF THIS DESIGN TO ERECTION CONTRACTOR REV 15.1.2 SCALE a 0.1875 c o 0 0 o c **IMPORTANT** ASLHPL21L NME OT BE FW slNGINEERED y FOR I Y IPE CAM WARNING W HANDLITAUSSES �N& DESIGN CRIT: UBC REF 8532--48586 C v C C DEVIATION FROM I ESE SPECIFICATIONS DR AMI DEVIATION FROM ERECTION AAM BMCINB.SEE •STT -76•. Mm=N6 WOOD TRUSSM TC LL 16 . 0 PSF DATE 11/17/89 G C O C THIS DESIGN OR ANT FAILURE TO BUILD THE M= IN CO/FORRAHCE COMMENTARY NO iELOMEIOATIO/8-ATPII. SEE DRWG CAUSR532 89321002 C O G O WITH THE •GUALITY STANDARD BSTSB• BY TPI. ALPINE CONNECTIONS TWO DESIGN FOR ADDITIONAL SPECIAL PEWA- TC OL 7. 0 PSF G C C C AHE NAHFACTUAW FRON 20 SAM GALVANIZED STEEL UNLESS HENT 9UCO6 NEGUIREMENTS. UNLESS OTHERWISE (U) 5.0 PI LPI MERE OTHERWISE MOM MEETING REGUINEWS OF ASTM ARAB GPAW A. BOTD WL P 040MSMALL BE LATERALLY BRACED CA BC OL PSF CA, -ENG rK— o OO APPLY COINECTON9 TO BOTH FACES AT EACH JOINT AND LDCATE AS SHOWN. BEARING MIDTHS ARE A' NOMINAL WITH PIOPESLY ATTA?EO PlTWDOD SHEATHING, TOT. LD . 28 . 0 PSF 0/A LEN. 36-0-0 C=3 TRU55 O uaEss OTIEAWISE SOW. BOTTOM CHORD WITH RIGID CEILING OR BRACING OUR 1.25 DESIGN STANOAPM CONFORM WITH APPLICABLE vROVIS1aNs OP AS SPECIFIED ON DESIGN. GG NOT USE THIS G C O O O C *NDS AND NTPI (PCT) . DESIGN WITH FIRE RETADANT TREATED LUMBER, .FAC . ■-_TPI - TOM PLATE INSTITUTE, NOS - NATIONAL OESION 9PECIFICATION FOR WOOD COSTAUCTION SPACING 24.0" TYPE- SPEC— . .. _..-.:::-.....�.-� .. ..... y(„.�.,,.. ,..... ..._ «. - • _. ......t.11-20 2 W%ju = ; .L A&lcu w o N R1J UM2. PHM'AHt 1-N f TOP CHORD 2X4 FIR -LARCH #1 BOT CHORD 2X4 FIR -LARCH 01 WEBS 2X4 FIR -LARCH STANDARD CONNECTOR PLATES MUST BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF I.C.B.O. RESEARCH REPORT #2949. ALL PLATES ARE TO BE CENTERED ON THE JOINT. LEFT TO RIGHT AND TOP TO BOTTOM, EXCEPT WHEN LOCATED BY CIRCLE OR DIMENSION. SEE DRAWING 130 FOR "PLATE LOCATIONS ON TYPICAL JOINTS." CONNECTOR PLATES DESIGNED FOR GREEN LUMBER PER NOS TABLE B.IB. 1.5X4 6.00 5X5 5X6 5X12 S TC X -LOC L -R: 0.29 6.35 12.18 18.00 25.43 30.31 35.71 A BC X -LOC L -R: 0.29 7.84 15.13 25.43 30.31 35.71 C SINGLE CUT WEB N -TC: i .2 ENDS: 6.8 � 0 (U) BOTTOM CHORD CHECKED FOR 10 PSF LIVE LOAD. w N ALL TOP CHORD SPLICES OCCURRING BETWEEN 0) PANEL POINTS ARE TO BE LOCATED AT APPROXIMATELY 1/4 OF PANEL LENGTH FROM PANEL POINT (WITHIN 12") AND W SHOULD NOT OCCUR IN PANELS NEXT TO A PANEL POINT SPLICE. N $A O O OI 3X6 1.5X4 3X4 2 6.00 3.00 12 18-0-0-I_1 B-0-0 15-1-12710-3-6 36-0-0 OVER 2 SUPPOR EAI--�L% `��.� f�, •�i�: 3.00�� 12 7X8 1.5X3 I-10-6-14 R-10920 W- 3.50" R-9920 W- 3.50' PLT. TYP.-ALPINE SEON-- 61785 FURNISH A COPY OF THIS DESIGN TO ERECTION CONTRACTOR REV 15.1.2 SCALE - 0.1875 0 0 0 0 0 0 E ATFRMS o C o C o o **IMPORTANT** No iE�SP01Q FOR I� DEVIATION PROM THESE SPECIFICATIONS OR ANY DEVIATION FRDN THIS DESIGN OR ANY FAILURE TO BUILD THE TRUSS IN COIFOAW� NIT" THE 'QUALITY STANUM 09760' BY TDI. ALPINE CONNECTORS ARE MANUFACTURED PRAN 20 GAUGE GALVANIZED STEEL OTHERNISE WOK MEETING REDUIREIENIS OF ASTM A44S GRADE A. CONNECTORS TO SOT" FACES AT EAON JOINT ANO LOCATE AS SHOW. KAMM WIDTHS ARE 4' NOMINAL UNLESS OTHMISE SHOW. DESIGN STANDARDS CO FDRN MITA APPLICAG.E PROVISIONS OF *NOS AM NTPI (PCT). PENE WARNING IN NANONIL EFlEOUIRE �TION Akio LZ GMCINS.SEE "WAT-78% OWACINS IMNO TRUSSESTC CWENTARY AND NECOBNOATIONS-WTPIN. SEE THIS DESIGN FOR ADDITIONAL SPECIAL PEANA- NEWT GRACING FEWIREMENTS. ULESS OTHERWISE %I Ma TOR CHORD STALL BE LATERALLY BRACED WITH PNOPERLY ATTAC ED PLYWOOD SHEATHING.TOT.LD. SOTTON 04M WIT" RIGID CEILING OR GRACING AS SPECIPIBO ON DESIGN. OD NOT USE THIS DESIGN WITH FIRE RETARDANT TREATED LUMBER. CA _ ..-.-..+�a�'..-.:-_.._ DESIGN CRIT: UBC REF 8532--48590 LL 16. 0 PSF TC OL 7. 0 PSF BC DL (U) 5.0 PSF 28. 0 PSF GATE 11/17/89 DRWG CAUSA532 99321006 CA -ENG 7fAIRY 0/A LEN. 36-0-0 DUR .FAC . 1.25 "—TPI - TRUSS PLATE INSTITUTE. - NOS -.NATIONAL DESIGN SPECIFTCATION.FOR WCOO CONSTRUCTION W .SPACING --24•:0-•..,w. TYPE. --SPE - -_ _ 17�2v/89 �r. i ►UP CHORD 2X4 FIR -LARCH #1 BOT CHORD 2X8 FIR -LARCH #1 .WEBS 2X4 'FIR -LARCH STANDARD. EXCEPT AS SHOWN :WI -2X4 FIR -LARCH #1 CONNECTOR PLATES MUST BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF I.C.B.O. RESEARCH REPORT #2949. ALL PLATES ARE TO -BE CENTERED ON THE JOINT. LEFT TO RIGHT AND TOP TO BOTTOM. EXCEPT WHEN LOCATED BY CIRCLE OR DIMENSION. SEE DRAWING 130 FOR "PLATE LOCATIONS ON TYPICAL JOINTS." ALL BOTTOM CHORD SPLICES OCCURRING BETWEEN PANEL POINTS ARE TO BE LOCATED AT APPROXIMATELY 1/4 OF PANEL LENGTH FROM PANEL POINT (WITHIN 12") AND SHOULD NOT OCCUR IN PANELS NEXT TO A PANEL POINT SPLICE. ALL NAILS SPECIFIED ARE COMMON WIRE NAILS. Recommended connection for 36-0-0 trusses at 24" O.C. to bottom chord: Simpson LU28. See catalog C -89H-1 for nailing specifications. 3X8 3X6 6.00c 2X8 3X TC X -LOC L -R: 0.29 5.58 10.00 14.42 19.71 BC X -LOC L -R: 0.29 5.58 10.00 14.42 19.71 2 COMPLETE TRUSSES REQUIRED FASTEN TOGETHER WITH : 16D NAILS TOP CH ------------------ 16" O.C. WEBS ------------------ 4" O.C. STAGGERED BOT CH ------------------ 5" O.C. NOTE: (1) 1/2" DIA. THRU BOLT MAY BE SUBSTITUTED FOR (2)-16D NAILS IN BOTTOM CHORD ONLY. SINGLE CUT WEB #-BC: 3 :2 ENDS: 1.5 THIS GIRDER HAS BEEN DESIGNED TO SUPPORT: FROM ONE SIDE --36' 0' OF SPAN FRAMING TO THE BOT CHORD OPPOSITE SIDE-- 2' 0. OF SPAN FRAMING TO THE TC/BC SPLIT GIVING A TC LOAD OF 46 PLF AND A BC LOAD OF 482 PLF CONNECTOR PLATES DESIGNED FOR GREEN LUMBER PER NOS TABLE 8.1B. 6X6 F�OFESSIO, 3X8 mMe w� r y� 3i/Q3 M 6.00 9 IL 3X6 Ifl 8X8 7X6 2X8 3X6 G_ 10-0-O_j_! 0-0-0 20-0-0 OVER 2 SUPPORTS ' R-5224• W- 3.50' R-5126# W- 3.50" PLT. TYP.-ALPINE 61797 FURNISH A COPY OF THIS DESIGN TO ERECTION CONTRACTOR REV 15.1.2 SCALE - 0.2500 I=3 o o Q o c **IMPORTANT** ��No�a� �Nat�Fc�a Iw'tir WARNING n+iwaLt�xe�rwe.E1c w .SND DESIGN CRIT; UBC REF 8532--4860 C=AM Dtvl,►rtor cMOII THESE sPEcrrtGTtoNs OR ANT oEvurloN FMON eMActNB.sas •err-»•, mnACINs IM MUSSES, Twasss TC LL 16.0 PSF DATE 11/17/89 THIS OWIGN OR AM FAILURE TO BUILD T7! TTRI!$ IM COTFQMAISE COMENTAPIr AND iETp�ATIONe-IPI) . 6EE rITN THE 'oualTr STANDARD 0918e' 9r TPI. ALPINE carMttrare THIS OE91oN FOR ADDITIONAL SPECIAL P'Ep1A- TC DL 7.0 PSF ORWG CAllSAg32 8932!018 AIN# NAMucAcruneDFnoNxoGAusEoALrANtzPD sTEFl WieseNENr eNACINerEautMe4l�Ts.ua.EseerIlEMwlsaCA BC DL 5•0PSF (:ArENGoTIE1Mt81< sN0101 IEETINe gEOUIiEIEMs aP ASTx ANA6 6RAOE A. 91QUtTTP o10i0 sIMLLBEuTEHALLreAACEDAPP{.r EON1ECTdIs TO eOTx FACER AT F.Id JOINT ANO WIa76 As wITN PfQEitT ATTACIED iLTMOOD SEATNIM3. TOT. LD28.O PS0A LEN.20-0-0 sNo1N. BEAAIIO NIDTxs AAE A• NOMINAL UNLESS OTHERWISE STOW. eoTTaN a+DAD WITH RIGID CELL IND aM enActaG DE9IGM 9TANDAPg9 DDNrDPN WITH APPLICABLE PMOVI92DN9 DF As SPECIFIED d DESIGN. OO NOT USE TN18 OUR. FAC . 1.25 PITCH 6.0 1 2 •MD9 A10 MTPI fPGT). DESIGN WITH PIKE RETARDANT TREATED LUMBER. C C C r --TPI - TPIUffi PLATE IN971TU7.. . Nag - NATIONAL aFviON svecrcECATION FOR MCOD.CDN.9TS81LTION ., SPACI.NG,:SEE. ABOVE TYPE- -:COMN-- .--'_ A D C N 33 N W N Ol (D W N M O 03 - 'e TOP CHORD 2X4 FIR -LARCH N1 BOT CHORD 2X8 FIR -LARCH SS WEBS 2X4 FIR -LARCH STANDARD, EXCEPT AS SHOWN :W1 -2X4 FIR -LARCH 01 CONNECTOR PLATES MUST BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF I.C.B.O. RESEARCH REPORT 82949. ALL PLATES ARE TO BE CENTERED ON THE JOINT. LEFT TO RIGHT AND TOP TO BOTTOM. EXCEPT WHEN LOCATED BY CIRCLE OR DIMENSION. SEE DRAWING 130 FOR "PLATE LOCATIONS ON TYPICAL JOINTS." BEARING BLOCKS -SAME GRADE AND SIZE AS BEARING MEMBER BRG LOC 1 00-00-00:1 BLOCK 12" LONG - 2 16d NAILS/BLOCK ALL NAILS SPECIFIED ARE COMMON WIRE NAILS. CONNECTOR PLATES DESIGNED FOR GREEN LUMBER PER NDS TABLE B.1B. Recommended connection for 36-0-0 trusses at 24" O.C. to bottom chord: Simpson LU28. See catalog C -89H-1 for -nailing specifications. 5X6 4X 6.00 3X8. 4X5 R-6621# W- 3.50' TC X -LOC L -R: 0.29 6.91 12.65 18.39 25.00 n BC X -LOC L -R: 0.29 6.91 12.65 18.39 25.00 C C N 2 COMPLETE TRUSSES REQUIRED F=====S (Mn FASTEN TOGETHER WITH : 16D NAILS N TOP CH ------------------ 16' O.C. WEBS ------------------ 4" O.C. STAGGERED 0) BOT CH ------------------ 5. O.C. NOTE: (1) 1/2" DIA. THRU BOLT MAY BE SUBSTITUTED GAJ FOR (2) -i6D NAILS IN BOTTOM CHORD ONLY. 111 SINGLE CUT WEB #-BC: 3 :2 ENDS: i. 5 0 THIS GIRDER HAS BEEN DESIGNED TO SUPPORT: Uf FROM ONE SIDE --36' 0' OF SPAN FRAMING TO THE BOT CHORD OPPOSITE SIDE-- 2' 0' OF SPAN FRAMING TO THE TC/BC SPLIT GIVING A TC LOAD OF 46 PLF AND A BC LOAD OF 482 PLF 7X6 5X6 6.00 NI , 12X14 A'9_7_4;1 . A -l_7 -A^1 -3-6 OVER 2 SUPPORT 4X5 3X8 11 4X5 R -6523,E W- 3.50* Can C `' ' ✓� r' G -Z PLT. TYP.-ALPINE SEQN-- 61784 FURNISH A COPY OF THIS DESIGN TO ERECTION CONTRACTOR REV 15.1.2 SCALE - 0.1875 0 o v c 0 0 o c o c e e e e o c C= o *(IMPORTANT** NDTBE At as>e�ie FFW `AW DEVIATION FON 7NESE SPECIFICATIONS 00 ANY MVIArrM# mm THIB DESIGN OR ANY FAMURE TO BUILD THE TRUM IN COFOR160CE WITH THE "QUALITY STANDARD 09788• BY TPI. ALPIE CONNECTORS WARNING SUNGEXTREME ION .`AM AND BRAMNS.SEE •arras•, wACINB ram TNjS2M COMMENTARY AND rlTA*60 Anoa-.TPI) . BEE TAMS 4gSION FOR ADDITIONAL SPECIAL PERIA- DESIGN CRIT: UBC REF 8532--48589 TC LL 16.0 PSF TC DL 7. 0 PSF DATE 11/17/89 DRWG CAUSA532 88321005 C� [� C=3 = o A�.PiN C o TRU55 C= O C� [� C� C= n ARE MANUFACTURED FROM 20 GAUUBE GALVANIZED STEEL UNLESS OTIERNISE MOW MEETING IEO{MO M8 OF ASTM A44GRADE A. AFPLr CONEC70" TD B07N FACES AT EACH NDINT NO LDCATE AS 900M. BEARING WIDTHS ARE 4' NOMINAL UNLESS OTHERNISE SHOWN. DESIGN STANDARDS CONFORM WITH AFPLICASLE PROVISIOa OF ' AND TORI (FCD). NENT OUCD18 NEOUIRE N9NTB. UNLESS GTTERHIBB "104 TDP C"GO SHAu BE LATERALLY BRACED WITH PROMLY AT►ACNED PL"M= SHEATHINQ CH GOTTON ORD WITH RIGID CEILING ORRA BCING AS SPECIFIED a OF.BIGN. m MY USE THISDUR DESIGN WIT" FIRE RETARDANT TREATED LUMBER. CA .r•- _. - BC DL 5.0 PSF TOT . LD. 28.0 PSF t CA -ENG % yAw 0/4 LEN. 25-3-8 .FAC . 1.25---][P-ITCH 6 . U 12 _•,.....M__TVI_. TTG,* .PLAIE INSTITUTE.:- Nag - NATIDNAL.DESTBN SPECIFICATIM FOR WOOD CONSTRUCTION. -1,- SPACING ..SEE -ABOVE• 4var= CONN-� -- •..z. RESIDENTIAL 69-54-15 AZTEC CONST 15 Osborne Ct, Orovil (open deck/sf) JOB FINALE Signature J=OK O = Not OK -=Not Applicable Not Ready RESIDENTIAL (E ' = Date UNDERFLOOR (Plans) OK except #'s 1. Zoning -Setbacks -Easements -Flood -Slope 2. Fig., Main; Soils-Elec. Grnd.-/ /" Fig. Depth 3. Fig., Garage; Soils-Steel-Elec. Grnd.-/ /" Fig. Depth 4. Fig., Porches & Decks; Soils -Steel-/ /Fig. Depth 5. Stemwalls, Main; Steel -Bloc kouts-Wrapped 6. Stemwalls, Garage; Steel -Bloc kouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/0 -Sewer Test 10. Gas Pipe; Size -Anchors 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 16. Water Htr.; Vent -Access -Combustion Air -Baffle 17. Water Pipe; Test & Anchor -Nail Protection 18. D.W.V.; Test -Fittings & Anchor -Nail Protection 19. Shower Pan; Test, First Floor -Tub Access 20. Test Tub & Shower, Second Floor -Tub Access 21. Gas Pipe; Size & Anchors Date Card B71 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 22. Fixture & Transformer Clearance -Ins. Protection 23. Elec. Receptacles Spacing -Lights & Switches at Doors 24. Size Boxes & No. of Conductors -Stapled 25. Romex Installed Close to Edge of Studs & C.J. 26. Equip. Ground made up w/Mech. Fastners-Bond Gas & Water 27. 2 Appliance Circuts in Kitchen & Conductor Size/GFI 28. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al. Insulated Neutral O Yes 0 No 30. Service -Riser Conductors & Ground -Main Disconnect 31. Equip. Clearances Panels-Motors-Mech. Equip. 32. Clothes Closet Light -Shower Light -Spa Light 33. Smoke Detector Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 34. A.C. Ducts Insulation & Support 35. Vent Fan; Exhaust above insulation 36. Condensate Drain & Overflow; Size & Grade 37. Furnance-Vent; Access -Comb. Air -Return Air Vent -115 outlet 38. Attic Access & Platform if Furnance in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Plans) OK except #'s 39. Sils, Proper Material & Anchors 40. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound 41. Bearing Walls over Girders & Floor Nailing 42. Draft Stop in Walls (rat proof) 43. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 44. Headers & Beam -Size & Bearing jingle & *Duplex) Date FRAMING (Continued) 45. Hangers -Post Caps -Anchors -Connectors 46. Cing. Joist-Rftr. ties -Purlins. -roof Brac-Truss-Shthng.-Rfng. 47. Fireplace Ties or Type A Flue -Fireplace Throat clearance 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 50. Garage Fire Protection Framing 51. Property Line Firewall & Openings 52. Ext. Doors -One 3' -Check Garage -3rd Story, 2 Exits 53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers 55. Siding -Nailing Veneer 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 57. Glazing Area -Glass Protection -Skylights -Plastic 58. Shear Walls; Nailing -Bolts 59. Insulation -Walls -Ceilings 60. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 61. Ext. Steps -Door & Sidelight Protection -Landings 62. Smoke Detector 63. Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 64. Bedroom Exiting 65. G.F.I. & Bath Fixtures & Tub Access -Spa 66. Elec. Trim & Subpanel; Breaker Sizes & Labels 67. Stairs & Rails 68. Fireplace or Stove; Clearances -Hearth 69. Elec. Outlets at Wood Panel; Int. & Ext. 70. Kit.Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance 71. Elec. Outlets & Receptacles at Kit. Counter ..72. Garage Fire Door; Swing -Landing -Closer 73. A.C. Duct in Garage -Damper 74. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage; Above Floor-Mech. Protection 75. Plb., Elec. & Mech. Equip. Listed for Location 76. Elec. Receptacles in Garage; (G.F.I.)-Romex Protection 77. Insulation -Foam -Looked in Attic O Yes 78. Guard Rails & Deck Construction -Post Caps 79. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor O Yes 80. Following instld.; Drive O Yes ❑ No; Walks ❑ Yes 0 No; Planters ❑ Yes ❑ No 81. Stucco; Brown -Finish 82. A.C. Unit; Disconnect, Electrical, Plumbing 83. Vents Above Roof; Plbg.-Appliance-Fireplace.-Clearance to Openings 84. Water Well; Disconnect, Electrical, Plumbing 85. Exterior Elec. Trim; G.F.I. Receptacle -Underground 86. Ventilation Throughout House 87. Glass Protection 88. Corrections from Previous Inspections 89. Gas Test -Meters Tagged; Gas -Electric 90. Water & Sewer Connected -C/O to Grade -HD Approval 91. Energy Compliance Certificate -Other Certificates Date Card B-1 Date Card B -1 - Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: (NOTE: An entry must be made each time you visit job site) d=OK 0 = Not OK - =Not Applicable =Not Ready MOBILE HOMES r ' Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/0 Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location -Clea rences-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap: / /" L" ft. / /"Nat. or/ /'L'ft./ /"LPG MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs: Coonectors Shthg: Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mash 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 7. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fell -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/0 to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs: Coonectors Shthg: Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mash 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone: 916/538-7541 APPLICAVON AND PERMIT PERMIT NO. ' 1528-91 ASSESSOR PARCEL NUMBER 69-54-15 ZONING R1 BUILDING PERMIT OWNER Aztec Const TELEPHONE 674-2370 SQ. FT. OCC. BUILDING VALUATION 628 open 4,396 OWNER'S MAILING ADDRESS 1290 Lincoln Rd Yuba City 95991 CONTRACTOR'SNAME owner TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER VNKNOWN Total Valuation is Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ 50.50 ARCHITECT OR LN (NEEP. _ LICENSE NO. Plan Checking Fee $ 25.25_ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS 15 Osborne Ct.Oroville Permit fee ; 85.75 PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF ®X Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S G W 10.00 ea TYPE OF WORK New ❑ Addition DX Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe work: Open dark _ Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 8001 OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check One): I am licensed under provisions of Chapt. 9, Div. 3 of the BuslneSS and Professions Code and my license is in full rce and effect. License No. �%��.��� Classification. ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ i, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. ( DWELLING OCCUP.8d) OR ADDNS. ACG. BLDGS. l yzQsgft NEW CONSTR. MULTI -OUTLET NON.RESID BRANCH CIRC ITS 2.50 ea /POWER APPARATUS IN (SINGLE OUTLET CIR. ) Ex. Occu pOUTLETS OR FIXTURES eL0xAL@30 Ex. Occup. OUED APPLNS. R TLETS ((RESID IEA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. Iv1 I have placed on file with the County of Butte Building Department V� a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating Cooling Hood 3.00 Ventilation permit Fee ; Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above -menti ned property for inspection purposes. I also agree to save, idemn' a keep harmless the County of Butte against all liabiliti ju,,n, ns is nd expenses which may in any way accrue against I sequ ce<ofthe granting of this permit. X Date �- �r� �T— Signa re of Applicant - -Iwne4 Contractor E]Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST TYPE - TOTAL F E A5/5 HAz. cuA PAgK scHL FL C PA PD ) H IS This permit is hereby issued unoer the applicable provi- sions of the Butte County. Code and/or resolutions to do work indicated above for which fees have been paid. DIRECITORM PUBLIC WORKS BY —' Date Ir -7-3-471 PER EXPIRES Date +� Z" --� Receipt No. 93542 WHITE-D.P.W.. YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT - COUNTY OFIBUTTE DEPARTMi NT OF PUBLIC WORKS BUILDING DIVISION � ~ PERMIT .-�' _'_....~.�.~.."'.S^"EE" ~ ` ' Permit No. ' At time of ermit application, I was advised the following data must be submitted prior to permit processing and/or i,�suance: 7 DATE RECEIVED APPhOVED 2. Plot plans in duplicate/triplicate, signed by preparer of plans -.77 3. Complete plans in duplicate/triplicate, signed by-p-re-p-arer. of pla' n**s* 4. Complete engineered plans and calcs, with wet signature on plans 'supporting ........... ���_-------� ` ------ 7 Statement of Intent for Non -Heated and AC Buildings ..-..... ..... -_-_-- Ei Engineered �uoodob��and �voutinduo���duplicateprior to plan check) --_--' 9. K8obi|ehome installation data including manufacturer's installation inotructiono....................................................... 10. Fees of ........ ............ .... ------11. Chico Urban Area fees paid ....................................... 2. Park fees paid ........ .... ............ .. .................. ...... .. 13. School District fees paid .............. 14. Sanitation approval from Health Department -_---_ 15. City ofChico plumbing 9ennit..................................... ^ -_----.16. F1cd plan and business license approval from City of \\ (see City for other requirements) � 17� Planning (A) Use:—(B) x. ------ �--------� Parking: ---------'''''' ------ 18. Improvements may berequired. Contact Land Development Section DPW 19. Driveway permit (construction approval required prior to occupancy) ' ------ 20. Pre -Inspection for required . . . pm'/»»n*^. request to . � Building Inspector (o�») ° �--_-- 21. Contractor's license information (No.. Name Style, C|eouificadon) ... ---__- 32. Certificate of VVorkmano Compensation Insurance .. .......... .. .... ' ---_-- 23. Owner -Builder Verification (Given to owner o. Mail to owner o)..... .��--_- 24. Recorded copy of Agricultural Acknowledgment Statement ......... 25. Letter ofsignature authorization ................................... �---_'26. 27. When. you issue the follows: _---_-' Mail or, --_----_Mai| to contractor. ~ �XTelephone nd hold for pickup at office. _--______De|ivorvv/inopeutoc Other Applicant Date Copy ufHaz-Matform sent —Health Dept. —Fire Dept. ----Air Pollution Date Copyofplanssent ----Health D—FireDept. —Other— Date— By. � _ followingdata must be submitted prior^,~~.,^ .~~.....: (""^.e""" item not checked uuvve), 1' Ind -ex permit for above items No. 2. Additional items required: ^ ` Contractor, designer, advised of above |,ed data by Contractor, designer, owner, was advised of above required da p hone _rnal I —count `6r by— date s approved by Date' '. -_--_--_ of plans ~`hold .. —File ~.~.~^ -ZAP .~..~ '. Copy -DPW '- ' - COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERT Nom. 7 County Center Drive - Oroville, California 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT ASS OR P[. EL N MB R - `J ZON G BUILDING PERMIT oWER TELEPHONE S0. FT. OCC. BUILDING VALUATION 4. O NE 'S MAILING ADORES n (� i yt co t� u Q O t � �S Q7 CO TRACTOR'S NAME M GL TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CO S RUCTION LENDER UNKNOWN Total Valuation Is Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Per -lit AR H TECT OR LN ;(NEEP. LICENSE NO. Plan Che,_king Fee $ Energy Plan Checking Fee ' ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADD 55 (9 r n P JCS Permit fee $ Q PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF� Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 1 5.00 Building sewer 5.00 Mobile Home S I G I W 0.00 ea TYPE OF WORK New ❑ Addition Rem del[] Utilitie tallation❑ Other ❑ Describe work: Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 Main service EA. ADO'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check One): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification. ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING OCCUP.ei� OR ADONS. ACC. BLDGS. '/z¢sgft NEW CONSTR. ULTI-OUTLET NON.RESID BRANCH CIRCUITS) 2.50 ea POWER APPARATUS h\ (SINGLE OUTLET CIR. EX. OCCUp(OUTLETS OR FIXTURES 20 @ 3 .AL0 FIXED APPLNS. OR Ex. Occup. OUTLETS (RESID.) EA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date Signature of Applicant — Owner ❑ Contractor ❑ Agent ❑ ( An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST TYPE �i n TOTAL FEE $ HAL CUA PARK SCHL FLO coF PAR PD I Ho. IssuE This permit is hereby issued unser the applicable provi- sions of the Butte County.Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By Date PERMIT EXPIRES Date Receipt No. WHITE-D.P.W.. YELLOW-A38C330R. PINK -INSPECTOR. GOLDENROD-AP►LI CANT Nc�;�N :. rn This set of plans and specifications —A kept.Qn:the.iob at all times and it is unit r ake'aii i Ganges or alterations on san -. • but written -taermtssion from the Departr :a Pubk Works. ;County of Butte. t4 .,.,Ali Materials & Workmanship Agcondak'e :with Recognized Good .Pro a gagli4X Prescribed for tFro S ifi VlAwin Wlding, Plumbing & Nl f%e:Na�tional:96ctricaol Cade.- 15 ods. 15(00 �. .A sett*ck of 5 ft- from the properly lines and a setback of 50 it; from the road centerline shall be clear of structures or equipment except for a Z ft. eave overhang. AAO to ZC'-O" W 7p.00' 0 �• ll�oor�( • • ae�k H wod -� Qeck N s e' f'U F- C5 f3G' N E CT. M I i.D r� O ' TTI J wod -� Qeck N s e' f'U F- C5 f3G' N E CT. M bnr, t.w veli it•, ZC�J3i t: ri to e:',: t' 1'n' ;:rityrn t'!?'i �v - .g .1-111 TU .. u__;..r,,: �.►-:;��� �.::.;,aa.- `i rid::. ��rs:tr►�;*a�, �a. f .► l;:�t� �� :J,,*'J e3 ..Stt, t .� � -�•. , r 1 ! ., ENTRY . GARAGE DEN 4' 15' DRIVEWAY 11,4 _i I I BEDROOM WOOD DECK N -► 5 o* dddNv' iDEP ARTMEN7 lROVElj AZTEC CONSTRUC N REAR DECK 150 N U L J- ti VA 2X8 JO r 2X0 RIM JOIST 12X 12 PIERS W/ 14X 14X 12 FOOTINGS E•' OC MAX 1/2" = 1 BUTTE COUNTY BUILDING DEPARTMENT APPROVED AZTEC CONSTRUCTION CO C1ECK CHET" -91 ®rV Lu II II Li Lu 0 _�j r-7 X v BUTTE CqUh MM De--PAFTM 1P'L ILI 1 4 %--4v Lu 0 _�j Lj r-7 X v BUTTE CqUh MM De--PAFTM 1P'L ILI 1 4 %--4v 10 RESIDENTIAL A 69-54-15 ..1921-90B, P,',,E. , M AZTEC.Construction 15 Osborne Ct, Oroville (new single family) y OFFICE COPY Address GAS Meter By Dat ELECTRIC Meter By Date Address - Date— ELECTRIC Meter By — Date 04/it JOB FINALE Signature J=OK O=Not OK - = Not Applicable = Not Ready RESIDENTIAL (Single &-Duplex) Date UNDERFLOOR Plans OK except #'s 1,1'i Coning -Setbacks -Easements -Flood -Slope '., Main; Soils-Elec. Grnd.- tg„De�th L3�Garage; Soils-Steel-Elec6ljgfg Ftg. Depth 4. Ftg., P ches & Decks; Soils -Steel-/ /Ftg. Depth a,ste'rnwalls, Main; Steel-Blockouts-Wrapped 6 mwalls, Garage; Steel-Blockouts=Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped ers-Fireplace Ftg.-St el W.V.; Fall-Fittin - est -2 Way -Sewer es 10. Gas Pipe; Size -Anchors Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground Pienums & Ducts; Clearance -Material -Support -Ins. 4 Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Insulation Date 6 Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date f PLUMBING Permit OK except #'s aig. ter Htr.; Vent -Access -Combustion Air -Baffle W Pipe; Te s Anchor -Nail Protection W .W.V ittings & Anchor -Nail Protection 19. Shower Pan; Test, First Floor -Tub Access 20. Test Tub & Shower, Second Floor -Tub Access _ 21. Gas Pipe; Size & Anchors Date Card B71 Date Card B-1 Date ;r^ and B-1 Date Card B-1 Date ELECTRICAL Permit OK exce t #'s 22,-gw-Aue_&Transformer lea= -Ins. Protection c. Receptacles mg- ghts & Switches at Doors 015�1'e Boxes & No. o onductors-Stapled Romex Installed Close to Edge of Studs & C.J. qup. Ground made up w/Mech. Fastners-Bond Gas & Water Appliance Circuts in Kitchen & Conductor Size/GFI 2Br6ubfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or At 29. Range Circ. /J7 ga. Cu or Oven Circ. / / ga. Cu or Al. Insulated Neutral Yes ❑ No rvice-Riser Conductors & Ground -Main Disconnect 1. E 'p. Clearances Panels-Motors-Mech. Equip. Clo es Closet Light -Shower Light -Spa Light L Smoke Detector Date Card B-1 Date Card B-1 Date ' Ri Card B-1 ,/� Date Card B-1 Date MEC NICAL Permit OK except #'s A.C. Ducts Insulation & Support 06. t -Fan; Exhaust above insulation Condensate Drain & Overflow; Size & Grade F' nance-Vent; Access -Comb. Air -Return Air Vent -115 outlet ,PeAttic Access & Platform if Furnance in Attic Date p 7 Card B-1 Date Card B-1 Date Card Date Card B-1 s) OK except #'s Material & Anchors alts Studs -Nailing, Spacin .9 -Bracing, Plates -Sound Bearing Walls over Girders & ailing ft Stop in Walls (rat proof) tops; Furred Ceilings -Stairs -Chases -Tub Headef Beam -Size & Bearing Date FRAMING (Continued) ties-Purlin—roof replace Ties or Type A Flue -Fireplace Throat clearance tic Access; Size & Romex Protection -Draft Stop -Ins. Baffles j69-15drm. Windows or Exiting Doors -Sill Hgt. & Dimensions Fire Protection 51 -.-Property Line Firewall & Openings i52!€xt. Doors -One 3' -Check Garage -3rd Story, 2 Exits 4"U Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 454 --plywood on Roof Overhang -Attic Vents -Rafter Outriggers ling Veneer QV t66-St=o Mesh -Drip Screed -Fd. Vents-Underflr. Access 57. iri rea (a ass Protection -Skylights -Plastic. Nailing -Bolts l�eQ Infiltration -Walls -Windows Date Z// Card B-1 Date Card B-1 Date Y14 Card B-1 // Date Card B-1 Date FINAL Plans O except #'s G. xt. Steps -Door & Sidelight Protection -Landings 2oke Detector 6� 3,.6amace; Vents -Clearance -Comb. Air -Connector - f/ In Garage; Above Floor-Ducts-Mech. Protection droom Exiting F.I. & Bath Fixtures & Tub Access -Spa . lec. Trim & Subpanel; Breaker Sizes & Labels Stairs & Rails Fireplace or Stove; Clearances -Hearth 489'Elec. Outlets at Wood Panel; Int. & Ext. Kit.Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance Elec. Outlets & Receptacles at Kit. Counter 7 Garage ire Do ; Swing -L ing-Closer 74�.r n 1 4n Garage -Damper Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage; Above Floor-Mech. Protection 7 b., Elec. & Mech. Equip. Listed for Location 7 . lec. Receptacles in Garage; (G.F.I.)-Romex Protection 4p -Foam -Looked in Attic Yes Guard. Rails & Deck Construction -Post Caps L7 . dn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor O Yes Following instld.; Drive - es ❑ No; Walks O Yes No; Planters ❑ Yes o $Town -Finish L,eA.C. Unit; Disconnect, Electrical, Plumbing Vents Above Roof; Plbg.-Appliance-Fireplace.-Clearance to Openings Disconnect, Electrical, Plumbing Exterior Elec. Trim; G.F.I. Receptacle -Underground 8 . entilation Throughout House Glass Protection 88. Corrections from Previous Inspections as Test -Meters Tagged; Gas -Electric Water & Sewer Connected -C/O to Grade -HD Approval L.Energy Compliance Certificate -Other Certificates Date Card B-1 Date Card B -1 - Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: (NOTE: An entry must be made each time you visit job site) J=OK O=Not OK =N ottReadyable MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/0 Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap: / P L" ft. / P'Nat. or/ /"L"ft./ /"LPG 7. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/0 to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 1E 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel y 3. -Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Coonectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes-Enclosures-PaneIboa rds-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ..^w-+^s'+:_t+`i,+'"9-rl'1Ss:4a.�-�"r'iE"``�"��"^'�-'r'=3F Y'"��'...+�a"��r-:'�^i!'a,.;r"'�-�ii�+:�."�+•�lf'�'[' �'--,y�""� COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 538-7541 747 Elliott Road, Paradise— Phone: 872-6307 CORRECTION NOTICE E A routine inspection indicates that the following violations of County Ordinance exist >atthe a ove address and should be corrected. Please notify this office when ion of work is completed. If you have any question pertaining to this matt ,eed additional explanation, please contact this office immediately. ' /_7-._ 1'e' Date Inspector �/ v� • '7-... .Y^-.�-.�1 vY >'1. -J . ' moi^ -; t71.,,,N';"LK="�ti11 .'Q- i. %,"°�."ary'�..=rviti:,.�,a,�. .- s-.:�.-• COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Orovi Ile —'Phone: 538-7541' 747 Elliott Road, Paradise — Phone: 872-6307 CORRECTION N0fi10E OW E P RMI T NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when corre .tion of work is completed. If you have any question pertaining to this matter r need additional explanation, please contact this office immediately. 1 t 92 (Zbtki�_—QrG e .e _ 1Z 12 i! V COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Orovi Ile — Phone: 538-7541 747 Elliott Road, Paradise — Phone: 872-6307' J CORRECTION NOTICE T NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter,_.jgvneed additional explanation, please contact this office immediately. d"y V s / ` I'd Date Inspector &/ / _ COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Orovi Ile - Phone: 538-7541* ` 747 Elliott Road, Paradise — Phone: 872-6307 ,CORRECTION NOTICE WNER PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. 1 Gi A G a �u� '1/ ����►� O/ �vv1A�� /bvIe� .r 4. e eAS 7d l - ��4-1 boo '.6s �n /1 t o 7-Y 4 ✓> die � �•� c��- � a i y Pd e oe q i J Date 7 �1 96 .ter Inspector 4k!�`— x ENJERGY .CER11"-Fr! ICAlirION L.o l 15 __.— S�(Trh ��'ov►�It LOCATION A. P. N0. ROOF Material Thickness— EXTERIOR hicknessEXTERIOR WALL Material— FIBERGLASS _ Thickness (inches)_ 3Yz---- CEILING 131 and Name Thermal Resistance (R Value) Brand Name _ CERTAINTEED_ . Thermal Resistance (R Value) l-__ Batt or Blanket Type FIBERGLASS_ Brand Name CERTAINTEED__ Thickness (Inches) 11 Thermal Resistance (R Value)3 $ _ Loose Fill Type._ FIBERGLASS _ 13rand Name CERTAINTEED Minimum Thickness (Inches)' IS-._ 1ju. of F3ags�► Weight/bag 25 -lbs Area Covered (Sq. Ft.) "759 __Thermal Resistance (R Value) 3 FLOOR,ELEVATED Material FIBERGLASS Thickness Inches) FLOOR, SLAB Material^ Thickness (Inches) _~ FOUNDATION WALL Material` Thickness V(Inches) _ ____ Brand Name CERTAINTEED _ _ 'Thermal Resistance (R Value)_ Brand Name _ _ Thermal Resistance (R Value). - 11r. end Name 11termal Resistance (R Value)____ I HEREBY CERTIFY THAT THE ABOV17 INSULATION WAS INSTALLED IN TDF••: ABOVE BUILDING IN CONFORMANCE WITtF THE STATE OF CALIFORNIA ENERGY REQUIREMENTS. HAWK I N.St-IN)US.TRIE5 Firm Name/Owner Signature _._.. 3 7 94 0 7..__.._ state Contractor's License No. -6-5r Date I HEREBY CERTIFY THE ABOVE INSULATION AND ALL REQUIRED ITEMS AS SHOWN ON THE BUILDING DEPARTMENT APPROVED PLANS AND ATTACHMENTS HAVE BEEN INSTALLED AS REQUIRED BY THE STATE OF CALIFORNIA ENERGY REQUIREMENTS. &- � CC_ . Fir Nlam /Own .r Signature eii. Con actor/owner Dyate Date :N COUNTY OP BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT PERMIT NO. 1921-90 ASSESSOR PARCEL NUMBER 69-54-15 ZONING BUILDING PERMIT OWNER Aztec Construction f TELEPHONE 674-2370 SO. FT. OCC. BUILDING VALUATION 1880 R 75,200 OWNER'S MAILING ADDRESS 1290 Lincoln Rd Yuba City 95991 470 M 6,580 CONTRACTOR'S NAME .Aztec TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace "Alt 1,000 CONSTRUCTION LENDER UNKNOWN Total Valuation $ 82.780 Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ 382.00 ARCHITECT OR ENGINEER LICENSE No. Plan Checking Fee ,$ 191.00 Energy Plan Checking Fee $ 15.00 ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS 15 Osborne Ct. Permit fee $ 8.0 PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 18.00 Oroville Solar or heat pump water heater 20.00 20.00 LOT NO. 15 SUBDIVISION NAME PARCEL M Kelly Ridge �J Water piping 5.00 5,00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF)Z Duplex[] Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 5,00 Mobile Home S I G W 10-00ea 58.00 TYPE OF WORK Newn Addition[] Remodel[] Utilities❑ Installation[] Other ❑ Describe work: I hdrm _ Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 10 00 Main service EA. ADD'L 100 AMP 2.50 2Z 5 CONTRACTORS LICENSE LAW I declare /er Snail of perjury 11HU penalty p I y (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in fullrce and effect. License No. D` J Classification Fl I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING oCCUP.& OR ADDNS. ACC. BLDGS. 2/z¢sgft 58.75 NEW coNSTR. ULTI-OUTLET 2,50 ea NON•RESID BRANCH CIRC ITS POWER APPARATUS e SINGLE OUTLET CIR. 20 ® 30C Ex. Occup OUTLETS OR FIXTURES aAL@30 FIXED Ex. OCCUp. OUTLETS PR RESID IEA.7 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ 81.25 Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating 6.00 Heat Pump Cooling 6,00 Hood 3.00 3,00 Ventilation Permit Fee $ 25.00 Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, ind fy and keep harmless the County of Butte against all liabilities, judgm ost9!and expenses which may in any way accrue agains d oun n sequence o the granting of this permit. X D Signature of Applicant Owner ❑ Contractor Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ 0 occ CONST TYPE TOTAL AL E FEE $ 792.2 5 2 AZ CUA PARK - PARAPD Ho Is his permit is hereby issued under ions of the Butte County Code and/or rk indicated abov for which fees I FR 0 PUBLIC 7(/,7(1/, By PERMIT EXPIRES ate the applicable provi- resolutions to do have been paid. WORKS Date •' Receipt No. 66802 - 237.00 Z� WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT .�,.r'�{,t"t'4"'r+,-tir`:,�'�'.ttM_"'�fia+.t_or... 5 � �ia�� �i'ii,`y1.L„-i.'' •�51+-K`� •.�+K.Gr.z..''se r^,:...,,..;'^r COUNTY OF B`U°jtE-aDEP,A•R'TME'NT OF PUBLIC WORKS -BUILDING DIVISION 7 COUNTY CENTER DRIVE - ORQVILLE, CALIFORNIA 95965 - TELEPHONE: 916/538-7541 PERMIT APPLICATION DATA SHEEt '-- Aa -T-� Permit No. ' / OWNER Aa T E' �� ---. A. P. No. -S4 l''Z 1 o Proposed Building Use 5�• _ Building Inspector' 4. Date � Co At time of permit application, I was advised the following data must be `submitted prior to permit processing and/or issuance ' DATE RECEIVED APPROVED a 1. All items have been submitted . ........................ .......... - 2. Plot plans in duplicate/triplic4te,,.signed by preparer of plans........ 3. Complete plans in duplicate/triplicate, signed by preparer. of plans . . 4. Complete engineered plans and calcs, with wet signature on plans .. 5. Hazardous Material Form ..................... ................. . 6. Energy Design Compliance and supporting documentation ......... 7. Statement of Intent for Non -Heated and AC Buildings ............... 8. Engineered truss details and layout in duplicate (required prior to plan check) 9. Mobilehome installation data including manufacturer's installation instructions 10: Fees of >� S ................... Chico Urban Area fees paid . . 12. Park fees paid ....................................... ._eAL C2 0417 f� School District fees aid .............. 1 Sanitation approval from z -dA Health Department /i S 15. City of Chico plumbing permit ..................................... 16. Plot plan and business license approval from City of (see City for other requirements) 17. Planning approval for (A) Use: (B) Parking: ...... 1 Improvements may be required. Contact Land Development Section DPW ll19. Driveway permit (construction approval required prior to occupancy) 20. Pre -Inspection for required ... Pre-Inspec. req est to Building Inspector (Date) 21. Contractor's license information (No:, Name Style, Classifications ... 22. Certificate of Workmans Compensation Insurance .................. 23. Owner -Builder Verification (Given to owner ❑, Mail to owner ❑) ..... Wecorded copy of Agricultural Acknowledgment Statement ......... etter of signature authorization .................................. . 26. 27. When you issue the permit, process as follows: t ail to owner. _ Telephone 6O7/Z3%Z2and hold for pickup at, office. Other /l i Mail to contractor. _Deliver w./inspector. , Applicant Date at �( Copy of Haz-Mat form sent )Iealth Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. �f Other Date By. The following data must be submitted prior o r it issua (C' le new item not checked above). 1. Index permit for above items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data by_phone_mail—counter by ..date Contractor, designer, owner, was advised of above required &tfky'�hone—mal l—counter by date Plans checked b, Copy—DPW Date Sets of plans on hold in4-File cabinet d by r LT Date - TO: Building Department FROM: Encroachmant Permit Section RE: 'Diiveway Clearance 14- r7z owner location AP # Driveway permit has been issued for the above property. n b Asign �re date 7 County Center Drive - Oroville, California 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT ASSESSOR PARC„€ `N� � (/a�[(� ZONIf:�/Cj / I /` BUILDING PERMIT OWNERZ I - '/(/// TELEPH N /, SO. FT. OC BUILDING VALUATION `� OWNES MAILING ADDRESS 10 G./SCO 12TH -y�� T I—CONWRAICTOR'S CONT 0�7 ,$ME TELEPHONE ' MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $1197 Energy Plan Checking Fee $ �� ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS Permit fee $ PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar or heat pump ter 7 20.00 0,p LOT�O/ (/ /7 SU BDI ISI N NAME ��� PARCEL 6 MAP Water piping � 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SIX Duplex[] Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S G yV 0008 �Q TYPE OF WORK Newel Addition[] RRemodel❑ Utilities El Installation[] Other E] Describe work: -3 612 Ad NON Permit Fee $ g i Contractor ELECTRICAL PERMIT Fi I ing Fee 10.00 1000 Main service 8111 OR LESS 100 . AMP OR LESS GO. Main service EA. AOD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑I am licensgd under provisions Of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. / DWELLING OCCUP') I/22sgft 7 l OR ADDNS. l ACC. BLOGS. NEW CONSTR. ULT'-OUTL, ET 250 ea NON.RESID BRANCH CIRC ITS ' /POWER APPARATUS &1 t (SINGLE OUTLET CIR. I I Ex. Occup(OUTLETS OR FIXTURES 120 0 50c aAL@30 FIXED APPLNS. OR Ex. Occup. OUTLETS IRESID.I EA.) 2.00 i Temporary service 10.00 k Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ j Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating �O 4 (/ log— Cooling ,� Hood 1 3.00 1 5,"90 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyor Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date Signature of Applicant — Owner ❑ Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ Q occ CONST TYPE TOTAL FEE $ r HAz CUA PARK SCHL FLD PA D Ho ISSUE This permit is Hereby issued under the applicable provi- sions or the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By Date PERMIT EXPIRES Date Receipt No. Z___ 023 WNITE-O.P.W.. YELLOW -ASSESSOR, PINK -INSPECT GOLDENROD -APPLICANT PERMIT NO: 70-90 Lake Oroville Area Public Utility District 1960 ElOn Street OROVILLE, CALIFORNIA 95966 533-2000 - DISTRICT APPROVAL AND VERIFICATION OF INSPECTION BUILDING SEWERS This verification form must be submitted to the.Butte County Department of Public Works Building Department prior to issuance of a building or occupancy permit, whichever is applicable. Prior to final approval by Butte County of a Building or an Occupancy Permit, a copy of this verification form, signed off by Lake Oroville Area Public Utility District, must be submitted to Butte County. Date: June 12, 1990 Applicant: AZTEC CONSTRUCTION Applicant Address: 1290 Lincoln Road, Yuba City, CA 95992 Applicant Phone No.: 674-2370 Property Location (s): 15 Osbourne Ct., Oroville, CA 95966 Kelly Ridge Estates Unit'8, Lot 15 A. P. No. (s): 69-54-15 Fees due: $900.00 SC -OR REgional Facility Charge Application for service approved: 5 LAKE OROVILLE AREA PUBLIC UTILITY DISTRICT Inspection(s) made and successful test(s) observed: Location: Date: Lake Oroville Area Public Utility District release to close permit: Date: By: Return to DPW AGRICULTURAL STATEMENT OF ACKNOWLEDGEMENT 9 0.W 38 9 5 2 FOR RESIDENTIAL DEVELOPMENT Section 26-8.1 of the Butte County Code requires this acknowledgement be recorded prior to issuance of a building permit. T The property described herein is adjacent ' 90-038952. Rec Fee 5.00_ to land or included within an area zoned Cheek 5.00 for agricultural purposes, and residents of this property may be subject to incon- Recorded Of f i c i a 1 ' Records ; veniences or discomfort arising from the County of use of agricultural chemicals, including, Y but not limited to herbicides, pesticides, Butte and fertilizers; and from the pursuit Candace J. Grubbs of agricultural operations including, cultivation, Recorder 2:12pm 11 -Sep -90 GF1 but not limited to plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricul- tural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property should be prepared to accept such inconvenience or disconform from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described. as follows: Lot 15, as shown on that certain Map entitled, "KELLY RIDGE ESTATES UNIT NO. 8", which map was filed in the Office of the Recorder of the County of Butte, State of California, June 26, 1981, in Book 80 of Maps, at pages 85, 86 and 87. Certificate of correction, recorded June 29, 1982, in Book 2734 of Official Records, at page 210, records of Butte County, California. Date: 94 State of Calif onria ) SS County of Sutter ) On this the 11 th_ day of September , 19_qn_, before me, the undersigned Notary Public, personally appeared Marvin L. Sipes Personally known to me. ® Proved to me on OFFICIAL of satisfactory CAROL CARP10 is �31�1TTER OUNTY �A t be the persons) whose names) My Com mission Expires June 14, 1s bscribed to the within instrument and acknowledged that he cuted the same for the purposes therein contained. IN WITNESS WHEREOF, I hereunto set my hand and official seal. the basis evidence. Present A.P. No. Q��Notary ublic END OF DOCUMENT OR01//(IF-WYAJYDOTTF /RR/GAT/OJV D/STR/CT W ATER and HYDRO -ELECTRIC 2310 Oro Quincy Highway P.O. Box 581 Oroville, CA 95965-0581 (916) 5334578 Mr. Ed Overhouse, Sanitarian Nov. 8, 1990 Butte County Department of Environmental Health 7 County Center Drive Oroville, CA 95965 A.P. 69-54-0-014 (437 Hillcrest Ave);69-54-0-015 (15 Osborn Ct); 69-54-0-023 (12 Osborn Ct) Dear Mr. Overhouse: This letter is to inform you that the necessary arrangements have been made with the OROVILLE-WYANDOTTE IRRIGATION DISTRICT, to provide treated domestic water to the above mentioned parcel. If you need additional infomation please omtact this office. Very truly yours, OROVILLE-WYANDOTTE IRRIGATION DISTRICT Michael J. Messina, Assistant Engine r/J i I BUTTE COUNTY SCHOOLS DEVELOPMENT FEE CERTIFICATION FORM (One Form per Building) A.P. Number Cf /� Building Department No. School District O/U) City D County ® Jurisdiction Property Owner A Z"Tl Q/U S7" Project Location/Address Subdivision 1 t- L L y l f D G e Lot Number Residential Development: Sq. Footage # of Living MHI Addition (Group R) Units Commercial/Industrial: a Sq. Footage New Addition (Including Exterior - Roofed Areas) . Buil ing Department Representative D to ******************************************************************* (Floor Plans reviewed by School District Personnel) District Id No. School District certifies that `6(Applicant Name) (Phone Number) ?�9-c (S reet Address) (City) (State) (Zip Code) has complied with the requirements of Resolution No. �9 940 by the pa ment of $-2 170, VQ representing g(J square feet.. School District Reprtsentative Date PAID BY CHECK NO. BANK- NO % - 34 79 - 1, x PAID BY CASH REMARKS: white -applicant, yellow -building department, pink -school district SCHOOL.FEE (8/88) OF PUBLIC WORKS ' COUNTY OF BUTTE - DEPAItT=Ville,' 7 County„ Center Dri�+e,l CA 9596 P$ONZE; 916;-• ( i t Aztec Construction. 6Y, 1290 Lincoln Rd1T �,1yf h16, 1990 . Yuba City, CA 95991 RE: Permit Appin #1919-90 for new single" r ' famil �g.� A.P69-54-144 With reference to the above .subject: _X4XAttached is: Application for permit Mobilehome Utilities Installation Sheet ,i- -RRR Building Plans Mobilehome Installation Information ph Engr. Calcs Typical Plan Sheet' Owner -Builder Verification Formc List of Codes Enforced OTHER 6 We need theJollowing information: Permit application signed and completed where indicated with all copies! Fees of $ payable to Butte County Treasurer. Certificate of Workmen's Compensation Insurance or check exemption etateP�e Contractor's License Law information or check exemption statement. Complete plans in including plot plane. _ Plot plans in Structural details in Com lets lana and calce in •. Complete p by registered engineer or I architect•.-• ' Energy design including 1 k !. Street and drainage improvement plan approval from Land Development Sec ion (D -P ,) .; : XXXXTwo (9) sets of plans in accordance with the changes marked in red. ;af Sanitation approval from Butte County Health Department at; 196 Memorial Way,' Chico 7 County Center Dr., Oroville Skyway & Elliott Rd., Paradise Planning approval from Butte County Planning Department, 7 County Center - Drive, Oroville, for �� :; , t• Completed Owner -Builder Verification feria. Recorded copy of deed showing Recorded copy of agricultural acknowledgemept statement. .'' �'' "i1ti� t t, i f , OTHER Please return red marked plans with re -submittal. Should you have any questions concerning the above, please contact this office. 1E!'!'jj, Yours very truly, William Cheff li Director of Public Works �! C:: +;I •' II�'j' I— it �!•1� 1 7i ail ' F. Glander i JFG/aj ;. ?j� Chief Building Inspector ENGINEERING County of Butte Building Department 7 County Center Drive Oroville, CA 95965 Subject: Complete & Energy Plan Check Project: Aztec Construction - #1921-90 (916) 872-0254 FAX (916) 872-9331 July 13, 1990 The submitted Plans, Energy & Truss Calc's & Details were reviewed and the required additional informations and revisions noted in red. References to Notes on Plans are listed on the attached ?Mork Sheet. Resubmittal of Plans and Truss Calc's & Details is required. Please return the marked -up Plans, Energy and Truss Calc's & Details with your resubmittal. Enclosed: 1 set of Construction Plans 1 set of Energy Calc's 1 set of Truss Calc's & Details Statement (under separate cover) Sincerely yours KC-4-� Frank L. Tyukos IF LU IMUHISERNa 5790 CLARK ROAD, PARADISE, CALIFORNIA 95969 Mr. James F. Glander County of Butte Building Department 7 County Center Drive Oroville, CA 95965 (916) 872-0254 FAX (916) 872-9331 Subject: Complete & Energy Plan Check - 2nd Recheck Project: Aztec Construction - #1921-90 August 22, 1990 The resubmitted Plans were reviewed and the required additional revisions noted on Plans in red. Resubmittal of Plans to FLT Engineering is NOT required. Enclosed: 1 set of Construction Plans (Original, R-1 & R-2) 1 set of Energy Calc's (Original & R-2) 1 set of Truss Calc's & Details (Original) Sincerely yours, Frank L. Tyukos OWNER'S NAME: - r . 1� �rK t [.C,L m RECEIVED PERMIT NUMBER: 1921— 9 h A. P. #: 59 - /E- DATE -7131 IV6 [RESIDENTIAL [NON RESIDENTIAL RECEIVED BY TIME_ --—————— ——— ——————————————————— REQUIRED PRIOR TO PERMIT ISSUANCE ———— — — — — —. FROM DATA SHEET REQUESTED BY PLAN CHECKER OTHER REQUESTED BY CORRECTION NOTICE F-] YES F-1 NO ITEM: LOCATION IN BUILDING WHERE CHANGE OCCURS: --------------------------------------- -WHEN APPROVED, PROCESS AS FOLLOWS: Mail to owner (Address) Mail to contractor. i1a�y^ (Name and Address) [Call 074- 2376 x/12/ and hold for pickup at Qom} office. Deliver with next inspection. REVISED PLAN CHECK FEES PAID: ' $15.00 $30.00 Additional Fees Not Required C'ertificate of Compliance:. Residential CFAR 1'ra)ed T1tk Lo 7 tt; FIL L\( r" kdAddrem VE RI E UU b- - I- V-1 A L , 1 0 Dwwi" Ptammit to � 00tnLad" Aumar Tdepbo" rolw[�/ Cbackcd 13 y, III ]IIII Ile t"P11"Ct MdhOd (Packages Point Syst=---- ------ CHMAU zVw Enfomowca AstDcy Use only GENERAL INFORMATION Total Conditioned Floor Area: BuUdingType: V Single Family Hotel/mow (check one or more) Multi -Family (cu than 4 stories) Addition Multi Famil (4 or more stories) Existing -Plus -Addition Front Entry Orientation: est / All Orientations (circle one or mom) Number of Dwelling Units: Floor Construction Type - to one or both) Infiltration Control: (circle one) BUILDING SHELL INSULATION. Component Insulation Izution/Comments Type I - . — R -Value (atfic. to garage, typical, etc.) Wall .............. Wall .............. . Roof ............. Roof..' ** - ***** Floor ............. Floor ............. Slab Edge..... GLAZING Shading Devices Glazing Arta Glass Type Interior Exterior Orientation (Single, double) (roller b1h4 etc.) Ovediang Framing Type Front.... -(so (Shxtesc� etc.) (MdAltwood) Front..,. �Vc PKA LE Left...... Left ....... Rear..... (xj Rear..... Right. ... (W) pp Right.... ( ) Skylight....... Skylight ....... THERMAL MASS Type/Covering Area Thickness (sl&b/e,posed. d1c. etc.) (f)IS LWALa—,- LAT2— "0.0 tyl T LocafiorvTription (IdtchcrL badL c1c.) Cer'tiftcate of Compliance: Residential CF -1R L07 l Sno)ed Two D kt< HVAC SYSTEMS Minimum Duct Type ((urnaoe,air Efficiency Location cmdidoner, Duct Output Manufacturer/Modell heat ) (SE, SEER,HSP (attic, etc.) R -Value Btuli . or a" rovedequal) i Z' LLEN 0 (� Q l , 11 V � Maximum Furnace Heating Output:. (��� Btuh HOT WATER SYSTEMS Tank Manufacturer/Model if System Type (stor a as, etc.) Ca acit or approved equal) $ cial Features) (,t:NS IF)LE PF, 4) PIAT TAI C INPMTNIC, SPECIAL FEATURES/REMARKS (Add extra sliects if iiccessary) COMPLIANCE STATEMENT 'This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Cliapter 2-53 and Title 20, Chapter 2. Subchapter 4, Article 1 of the California Administrative code. This certificath has been signed by the individual with overall design ttsponsibl ity and the building owner, who shall retain a copy of it and transmit file certificate to any sub6cgucnt purchaser of the building. When this certificate of compliance is submitted for a single building plan to be burls in multiple orientations, all building conservation featrues which vary are indicated In the Special Features/Rematics section. Designer CJUulIdi�Own,, -tCJ�V Nuns:L I Title 74M L l ( I LI N, l'. 60 Address: I v E n . Addxea: Imp N. (s ittunure) Documentatlon Author (dAw) Tetept,�,x: , (sil m) (dak) Enforcement Agency Nuns; Agency: Tekpt�or� (tl�tattttc or ttunpj (due) Point System Summary: Climate Zone 11 MR AZT E(., M AJW • LO T l 5 (0 Project Title Date BUILDING DATA Glpss Area % Glass Conditioned Floor Area Number of Stories North X5.00 (2 _L 1 Slab/Raised Floor East f,S001South '�t.o� Check all applicable Unit Type condition(s): West 121 P,rSingle Family Detached (SFD) Addition Alone Skylight Single Family Attached (SFA) Existing Building Total Multi-Family(MF) Existing -Plus -Addition 7 SCORECARD Measures Point Scores 1. 'Ceiling Insulation or R -value [381 U -value J0.0301. A 2.. Wall Insulation I or R-value[II] U -value 10.0981 3. Raised Floor Insulation ( '9 or R -value 119) U -value (0.0371 4. Slab Edge Insulation or R -value 101 R factor J0.77] • 5. Infiltration Standard 0 — 6.. -.G.1iss Heat Loss L • Type [double] U -value 10.651 % Total Glass 16) Sum 1.6 7. Shading (Shade Open) % Glass SC Eff. % Glass a. North x .17 b. East X = 2.66 c. South X K I I I d. West X e. Skylight X 8. Shading (Shade Closed) % Glass SC Eff. % Glass a. North X b. East X c. South X d. West X e. -Skylight x_ --_-- a 9. Interior Thermal Mass Interior Mass/CFA 10. Exterior Wall Mass - , .' 0 Exterior Wall Mass Sum7-10 11. Heating System x Zonal Control? Y N SE or 14SPF Duct Efficiency [0.78] Effective SE or 10.7216.61 HSS/PF [0.56/5.151 12. Cooling System d, X + Zonal Control? Y N Duct Efficiency 10.741 Effective SEER 17.03] 13. Water Heating Type [SGJ Credit [none] Point Total: Form Revised March 1988 Climate Zone IX . Point Tables 1. Ceiling • Insulation 4, Slab Edge Insulation 7. Shading (Shade Open) R value Number of stories One Two Three Il -value One Number of Stories Two j R-0 -103 49 •32 R-0 0 Three Effective Percent Class (percent glass x SC) R-19 R-30 -8 4 .2.1 -2 1 1 R-5 8 0 5• 0 2 Effective R-38 0 p R-7 8 6 3 %Glass North East South West Skylight • U -value w F2 factor 18 5 1 4 1 0.50 -176 -84 -54 0'90-4 0.80 -1 -3 -1 -1 0 16 4 2 5 1 14 4 2 5 1 na na 0.30 0.10 -102 49 26 13 -32 g 0.70 2 2 1 12 3 3 5 2 na na 0.08 0.06 -18 -9 -6 0.60 6 0.50 9 4 6 2 3 11 3 3 5 2 10 2 3 5 2 na 1 ' 0.04 -11 -5 4 2 -4 1 0.40 12 8 4 9 2 3 5 2 2 0.02 4 2 1 8 2 3 5 2 7 1 3 4 2 2 2 0.00 11 5 3 6 5. Infiltration (Air Leakage) 5 1 2 4 2 3 • Specification 4 0 � 3 1 3 3 ' 2. Wall InsulationStandard Points o 0 1• 2 le .--�0 X01--�� 0 3 , 2 Single- Single- Family Family Multi- 11 •2 4 •2 0 • R -value Detached Attached Family na not allowed = . R=0 . -68. -51 -34 6. Glass Heat Loss R-11 R-13 0 0 2 2 0 1 Total U -value R-19 8 6 4 Percent Glass Single Double .51 to .60 .41 to .50 .31 to .40 0.30 or less $, Shading (Shade Closed) U value 50 -121 •53 -39 . -24 •10 4 Effective Percent Class 0.80 -153 •114 -76 40 •90 -37 .-26 -14 -3 8 (percent glass xSC) 0.50 -91 -68 46 35 -75 -29 -19 -9 1 10 .0.30 47 -36 •24 30 -61 -21 -13 -4 4 12 Effective 0.10 0.08 0 0 4 3 0 2 29. -58 •20 28 -55 -18 -12 -10 -3 5 5 12 %Glass North East South West Skylight .. 0.06. 9 7 5 27 -52 -17 -9 -2 -2 6 13 . 13 18 14 48 69 64 na 0.04 14 11 7 26 -49 •15 •8 -1 7 14 . 16 • -12 -42 -59 -55 na 0.02. 19 .' 14 10 25 46 -14. -7 0 7 14 14 -10 -35 -50 -46 na 0.00 24 '', 18 12 24 -43 -12 •5 1 8 14 12 -8 -29 -40 -37 na 23 40 -11 4 2 8 15 11 -7 •26 -36 -33 na 22 -37 •9 -3 3 9 15 10 g 23 31 29 74 21 -34 -7 4 10 15 9 -5 -20 -27 -25 -65 ,. 3. Raised Floor Insulation 20 . -31 -6 19 -29 -4 0 0 1 5 6 10 11 , 16 16 8 -5 -17 -23 -21 7 4 -14 -19 -18 -13-47 •56 ' • , 18 -26 -3 2 7 12 16 6 •3 -111.4-15 14 -12 -38 Insulation In Floor 1723 -1 3 8 12 17 5`-� g 1T -fib -11 -30 • 4 •-1 6 -8 7 23 • . Number of stories 15 6 0 14 17 .3 0'-- 4 5 4 16 R value One TwoThree 14 ' -14 3 7 10 14 • 2, 7--f 'i 2 -1 •-1 ' -9 A-0 -17 -8 -5 13 12 4 8 11 15 .18 18 1 >t 'i�1 - o . 1 -4 R•11 -3 •2 -1 12 -9 6 9 12 15 19 0 2 3 4 3 0 R-19 0 0 0 11 -6 7 10 13 16 19 na = not allowed R-30 3 1 1 10 -3 . 9 11 14 17 19 • U value 9 -1 10 8 2 12 13 14 15 16 17 18 20 20 0.60 -144 -70 46 0.50 -120 -58 -38 0.40 -95 46 -30 0.30 -69 -34 -22 0.20 43 -21 -14 0.10 -17 -8 -5 0.08 •11 -6 •4 ' 0.06 -6 -3 -2 0.04 -1 0 . 0 0.02 4 2 1 0.00 10 . 5 3 . Controlled Ventilation Crawlspace Number of stories PI -value ' One Two Three i R-0 1.1 -7 •5 R•5 4 -4 3 R-11 •2 -2 -2 R-19 -1 -2 -2 +i .. 4-68 Energy. Conservation Manual... .:-:-..Revised March •1988^• Point Tables -9. Interior Thermal Mass Exterior Single- ' t' • Interior SEER Slab Floor Family Raised Floor Mass' - ' Mass Attached Stories 0.00 0 Stories 0 /CFA One Two Three One Two Three 0.0 -8 -5 4 -2 -1 -1 0.1 -8 -5 -3 -1 0 0 0.3 -7 4 -2 0 1 1 0.5 -6 -3 -1 1 1 2 0.1 -5 -2 -1 1 2 2 0.9 -5 .1 0 2 3 3 1.1 -4 -1 1 3 4 4 1.3 -3 0 2 3 4 5 1.5 -3 1 2. 4 5 5 •_ 2.0 -1 2 4 5 6 7 2.5 0 3 5 7 7 8 3.0 1 4 6 8 8 9 3.5 2 5 7 9 9 10 ' 4.0 3 6 8 9 10 10 .'• 4.5 3 7 8 10 11 11 5.0 4 7 . 9 11 12 12 5.5 5 8 9 11 12 12 6.0 5 8 10 12 13 13 6.5 6 9 10 12 13 13 7.0 . 6 9 11 13 13 14 7.5 6 10 11 13 14 14 8.0 7 10 11 • 13 14 14 8.5. 7 10 12 13 14 15 10. Exterior Wall Thermal Mass Exterior Single- Single - SEER Wall Family Family Multi Mass' Detached Attached Family 0.00 0 0 0 0.20 3 2 1 0.40 " 5 4 3 • 0.60 8 6 4 0.80 10 8 5 1.00 13 10 7 1.20 13 12 8 1.40 12 13 9 1.60 10 13 11 1.80 10' 12 12 2.00 10 11 13 11. Heating System 0 4 0 0 SE or JISPF 5.50 5 .(assumes ducts In attic) 4 3 Sum of 1-6 2 0.7 •25 or -24 to -14 to -4 to +6 to 16 or SE HSPF less -15 -5 +5 +15 more 0.72 6.60 0 0 0 0 0 0 0.75 6.88 3' 3 3 2 2 1 0.80 7.33 8 7 6 5 •4 3 0.85 7.79 13 11 10 8 7 5 0.90 8.25 17 15 13 11 9 7 0.95 8.71 20 .18 15 13 11 8 continued . . 0 Zonal 11. Heating System (continued) Effective SE or HSPF (SE or HSPF x duct eMciency) 12. Cooling System SEER (assumes ducts In attic) Sum of 7-10 -25 or -24 to -1410 -4 to +6 to Sum of 1-6 SEER less Effective -25 or -24 to -14 to -4 to +610 16 or SE HSPF less -15 -5 +5 +15 more 0.30 2.75 -73 -64 X56 -47 -38 -30 na 3.41 -45 -39 -34 -29 -24 -18 0.40 3.67 -34 -30 -26 -22 -18 -14 0.50 4.58 -10 -9 -8 -7 -5 4 0.56 5.13 0. 0 0 0 4 0 0 0.60 5.50 5 5 4 3 3 2 0.7 2 -24 15 13 1.1 9 7 0.80 7.33 25 22 19 16 7 13 10 0.90 8.25 32 28 24 20 17 13 1.00 9.17 37 32 . 28 ' 24 9 19 15 0 Zonal Control Adjustment to 3 5 System Type 22 19 16 113 10 7 11.0 26 Resistance 10 9 7 6 4 3 Other 13.0 6 5 4 3 2 • 2 12. Cooling System SEER (assumes ducts In attic) Sum of 7-10 . No Cooling System Installed Stories -One -5 4 4 -3 -2 2 Two + 3 3 2 2 2 1 Climate Zone 11 13. Water Heating -25 or -24 to -1410 -4 to +6 to 16 or SEER less -15 -5 +5 +15 more 8.0 -14 -12 -10 -8 -6 -4 8.5 • -9 -7 .%-6 -5 4 -3 8.9 -5 4 -4 -3 -2 -2 9.0 -4 -3 -3 -2 -2 -1 9.5 0 0 0 0' 0 0 10.0 4 3 •3 2 2 1 10.5 7 6 5 4 3 2 11.0 .10 9 7 6 4 3 12.0 15 13 11 9 7 5 13.0 20 17 14 12 9 6 2 2 Effective SEER POU 8 5 (SEER x duct erficlency) 3 SE None Sum of 7-10 -24 -18 Effective '25 or -24 to -14 to 4 to +6 to 16 or SEER less -15 -5 +5 +15 more 5.0 -30 -25 -21 -17 -13 -9 6.0 -12 -11 -9 -7 -6 4 6.6 -5 4 -4 -3 -2 -2 7.0 0 0 .0 0 0 0 '80 9.0 9 16 8 6 -7 5 14 12 9 4 7' 3 5 10.0 22 19 16 113 10 7 11.0 26 23 191 15 12 8 12.0 30 e 26 22 11 18 14 9 13.0 33 29 24 20 15 10 Zonal Control Adjustment 10 8 7 6 4 3 . No Cooling System Installed Stories -One -5 4 4 -3 -2 2 Two + 3 3 2 2 2 1 Climate Zone 11 13. Water Heating Single -Family Detached and Attached Unit Size (sQ Water 1199 1200 1700 2200 2700 Heater Credit or to to to or Type Type less 1699 2199 2699 more SG None 0 0 0 0 0 or Solar 12 8 6 5 4 HP HWR 8 5 4 3 3 WSB 5 3 3 2 2 POU 8 5 4 3 3 SE None -37 -24 -18 -15 -12 Solar -1 -1 -1 0 0 HWR -18 -12 -9 -7 -6 WSB -25 -16 -12 -10 -8 POU -18 -12 •9 -7 -6 IG None -5 -3 -2 -2 . -2 Solar 7 5 4 3: 2 POU 3 2 1 1 1 IE None -28 -19 -14 .11 9 Solar 8 5 4 3 3 POU -10 -6 -5 -4 ' -3. Multi -Family (Individual units) Unit Size (sQ Water 699 700 1200 1700 2200 Heater Credit or . to to to or Type Type less 1199 1699 2199 more SG None 0 0 0 0 0 or Solar 14 7 5 4 3 HP HWR 9 5 3 2 2 WSB 9 4 3 2 2. POU 9 5 p3 2 2 SE None 45 -23 -15 -11 -9 Solar 2 1 1 0 0 HWR -23 -12 -8 -6 -5 WSB -25 -13 -8 -6 -5 POU -23 -12 -8 -6 -5 IG None -8 4 -3 -2 -2 Solar 6 3 2 1. 1 POU 1 0 0 0 0 IE None -30 -15 -10 -8 .6 ' Solar 18 9 6 4 4 POU •8 -4 -3 -2 -2 F-5 Point System ._ _._... ._._.:__. - - .. 4-69 Culculutlon.ProcedUres .A, B, C, D Celculallon Procedure A - Summer Inflilrsllon for the Entire House 1. Air Changes Per Hour from Table 5.. 2. Volume of Conditioned Space ............ • .... • • • • • • • • • • • ailing • ' ght ACIHn • • • • • • • • • Floor Area X Calling H Iphl 0. Total Infiltration a � A(WU 8q. FI. X ( 7) FI. a4�0 Cu. F1, Cu.Ri 0.0197 =-CFM Celculntlon Procedure B • Summer Inllllrallon Him For Windows L Door$ 1. Design Temperature Difference = Summer Design • Roam Temperature _ ?j IF 2. Total Infiltration from Calculelpn Procedure A .. , , , • , , , L.....,.....CFM•...... 0. Sensible Gain = 1.1 X FX'•Z 4. Toldl Arne of WI d w nd Doors (Lines 7 & 8 on J) -i-�--- Q� p Bluh 5. H1m = - b t 131uh+ _ � •�• Sy. F1............ Sq. FI. BluhISq. F1. Cnlculnllan Procedure C • Lolenl Inlllltellon Gain For The milte House 1. Grains of Moisture Difference from Table 1 , 2. Tolol Inlltlrellon lrom Calculation Procedure A , , .......... .... • 0. Total LOWLoad = 0.68 X pr X = CFM • • • . CFM . Biuh Colculallon Procedure. D • Equipment Sl:ing Calculation Mechanical Vonlliellon Temp. Swln Vent CFM Mullipilers -4 Design Temp. Dill, No, 1; Calculation Procedure 6 IF Dill, Summer DS N 6' IA • �• 65.90 Design Grains No. t; Celculellon Procedure C gr 95 0.70 0.85 1.00 DeslreO Temp, Swlnp ( ) 0.75 0.90 1.00 Temp. Swing Multiplier (TSM) 100 0,80 O.BS 1.00 105 0.85 1.00 1.05 - 110 0.90 1.05 1.10_ Sensible Ventilation Load = 1.1 X Vent CFM X IF Sensible Load for Structure from Llne 19 0II1. n Bluh ............. Total Sensible Load .................... . .. . . . . . . . ..... . . .+ . . . . . . . (Structure Load + Venlllrallon Load) o Temperature Swing Multiplier X _ (TSM) Sensible; Equlpmenl 84ing Load ........ r Bluh Went Load [or Appllancea & People 200 X _ .,, People . 7116 0(a �_ Btuh Want Ventilation Load = 0.68 X Vent CFM X on+ Lelenl Infiltration Load from Calculation Procedure C,,,,,,,,,,,,,,,,,,,,,,, Bluh + Lelent; Equipment Sliing Load �Bluh , , 2, FOf1M J--1 Including Cnlculallon I'locedurhs A. 8. C, D ConYrlpht by Iho Alr'Condilloning Contractors of Amnrlon Formerly: Nnitonal Environmental Systems Conimclors Ansoclatlon 1220 17th Street N.W. Wnshlnp— D.C.20o:1n Printed In U.S.A. WORKSHEET FOR MANUAL J 1982 LOAD CALCULATIONS FOR RESIDENTIAL AIR CONDITIONING Plan No. — Dale Calculated by For: Narne �L I tG Address __ .0Z IS. City and Slate or Province By: Contractor Address City .1�,ELLY MME I Design Conditions Winter Summer Outside db 1: • F inside db 70 ' F Oulsldo db —iv]— • F Inslde db � _' F Winter DesignTemperalurn Difference 'F Summer Design Temperature Difference 2.3 'F —_-- — – _ Grains _—_ Dally Range ilahnlln Summary Total HeilI Loss Iclt Entire House (Line Is) _ _._. J I �JZ + I, b 00 8luh Venlilalitin CFM _ _ _ Wlninr Design Temperature Difference - _ _ 'F Heat Required for Vontllallon Air = 1.1 X �_ CFM X 'F Design Healing Lond Requirement = _ —_ (house) - (Vent)' g'th (;0011119 Summary M�}� Total Senslblo Galll % _ gtuh ((;nloulnllon Prore.duro D) Design Temporaturo Swings Total Lalnnl Gain I. Bluh (Calculation Procedure D) Normal 3' ( X ) 4.5' Total = ;lens. A. Lat. _ _��° _ 81uh Ventllalion CFM = �I oto Equipment Summary �� Make .Lv_�� �._ Mod(,71 Healing Input (Dlull)__2�1e Henling Output (Bluh) -Efficiency Sensible I;ooling (llluh) `I I- _ Lalnnl Cooling 131uh) Total (81u COPIEERISEER ►0 • Coaling CFM Healing CFM _ Space Thermoslal Heal( ) Cool ( ) Heal/Cool ( ✓) Constructlon Data Windows Floor Doors_ Walls Roof Celling Partitions Basement Walls Ground Slab Night Setback I ) 6 ac�a�aoa HS16 SERIES CONDENSING UNITS (1-1/2 thru 5 Nominal Tons) *19,000 to 62,500 Btuh Cooling Capacity 'DOE and ARI Standard 210 Ratings `, ,•,i J°��xolxr ,�e� jI^�pO r° ' « I(nlutgx ansa oMr c[�IrIUIgN •mat ox(r WN(xUfg at L*TtDIIID1. iOMtgM,NI! A! WT[p COMrON(Nn [! l(f 110 WIIx MI M'It111D1 Typical Applications Unit on slab at ground level. Mutiple units on rooftop. NOTE — Specifications. Ralinas end Dimensinns raiWart to ENGINEERING DATA I:.. . COOLING UNITS CONDENSING UNITS Page 19 November 1988 Supersedes April 1988 Model Dependable HS16 Condensing Unit Line Offers High SEER Ratings With Low Operating Costs HS16 Series condensing unit design features high efficiency, quality construction, sound engineering and dependable operation. The combination of coil circuiting, wrap-around "U" shaped coil and uniform condenser air distribution result in high seasonal energy efficiency ratios. Units are applicable to expansion valve systems and may be installed in multiples or singly in residential or com- mercial applications. Upward discharge of condenser air and low silhouette makes it easy to conceal the unit on a slab at grade level or behind a parapet on a roof. A large selection of matching blower powered and furnace add-on evaporator units are available to pro- vide a variety of cooling capacities for selective sizing and installa- tion versatility. The rugged galvanized steel cabinet has a durable baked -on out- door enamel finish for long lasting protection from varying climatic conditions. "U" configuration designed condenser coil provides extra large surface area and low air resistance for maximum cool- ing capacity. Dependable long life seamless copper tubing is used in coil construction. Powerful direct drive fan draws air through the condenser coil and discharges it vertically protecting lawn and shrubs from hot air. Rugged non -corrosive steel wire fan guard and coil guard are furnished. Thermostat is not furnished and must' be ordered separately. Condensing units are shipped completely factory assembled, piped and wired. In addition, each unit is test operated at the factory insuring proper -;start-up and operation. The installer has only - to set the condensing unit in desired location, connect refrig- erant lines and make electrical connections. , . •' ARI RATINGS Condensing Unit "ARI Standard 210 Ratings Evaporator Unit Model No. *ARI Standard 270 SRN (bels) SEER (Btuh/ Watts) Cooling Capacity (Btuh) Total Unit Watts Up -Flo Down -Flo Horizontal Expansion Valve Kit HS16-211V 9.75 19,000 2120 C16-21FF CR16-21FF ---- 10.05 19,600 2120 '"CB18-21 ---- "CBS18-21 9.80 19,400 2140 CH16-21FF 10.20 20,200 1905 ""CB19-21 "•CB19-21 ••CBH19-21 (7.2) 10.35 20,400 2160 C16-28FF, C16-28WFF C16-31FF, C16-31WFF CR16-31FF CH16-31FF LB-53081CF 10.55 20,600 2150 "CB18-26 "•CBS18-26 10.75 21,200 2180 C14-26FF 11.00 21,200 2120 ---- "'CB15-41FF 9.20 22,000 2670 C16-21FF CR16-21FF ---- 9.30 23,200 2715 "CB18-21 ---- •"CBS18-21 9.65 23,400 2664 "'CB19-21 ""CB19-21 "'CBH19-21 9.40 23,400 2740 ---- ---- CH16-21FF 9.60 24,200 2781 "CB19-26 ""CB19.26 'ICBH19-26 HS16-261V 9.60 24,400 2785 C16-28FF, C16-28WFF C16-31FF, C16-31WFF CR16-31FF CH16-31FF (7.2) 9.70 24,600 2802 "CB19-31 "CB19-31 ".CBH19-31 LB-53081CD 9.50 24,600 2815 "•CB18-26 ---- '•CBS18-26 9.55 24,800 2805 "•CB18.31 "•CBS18-31 9.70 25,000 2805 C16-41 FF C16-41 WFF CR16-41FF CH16-41FF 9.80 25,600 2825 C14.26FF ---- _--. 10.55 26,400 2710 ---- "'CB15-41FF H S 16-311 V ( (7.8) 9.70 30,000 3415 C16-28FF, C16-28WFF C'16-31FF, C16-31WFF CR16-31FF CH16-31FF LB-53081CD 9.70 30,000 3395 '"CB18-26 ---- "CBS18-26 10.20 30,800 3255 ""CB19-26 ""CB19-26 ••CBH19.26 9.80 30,800 3455 1 ""CB18-31 ---- ""CBS18-31 10.00 31,200 3455 C16-41 FF C16-41WFF CR16-41FF CH16-41 FF 9.90 31,200 3470 "'CB18-41 --- "'CBS18-41 10.15 31,800 3480 C14-26FF ---_ _.__ 10.35 32,800 3489 "•CB19-31 '•CB19-31 "'CBH19-31 4-4 3350 .... ••CB15-41FF 10.40 33,400 3530 C14 41FF 9.50 33,000 3760 C16 -25F1`-- WFF C16.31FF,.C16.31WFF CR16-31FF CH16-31FF , 9.55 34,400 3890 "'CB18.31 ---- ••CBS18-31 9.85 35,600 3935 ---- CR16-51FF ---- H S 16-411 V (7.6) 9.70 35,000 3905 C16-41FF C16-41WFF CR16-41FF CH16-41FF LB-53081CB 9.65 35,000 3940 ••C818-41 ---- ""CBS18-41 9 .80 35,600 3930 C 16-46FF C16-46WFF ---- 10.70 36,200 3811 ••CB19-31 ••CB19-31 ""CBH19-31 9.70 36,200 4050' "CB18-51 ---- "'CBS18-51 10.00 36,400 3975 1 C16-51FF ---- CH16-51FF 10.75 36,600 3812 "CB19.41 "'CB19-41 '•CBH19-41 10.75 37,800 .3878 "'CB19-51 ""CB19-51. •"CBH19-51 10.20 37,800 4045 C14-41FF -_-- _--- 10.60 37,400 3845 .. --- `• •': `= "' C B 15-41 FF 'Rated in accordance with ARI Standard 210 and DOE; 95°F. outdoor air temperature 80°F db/67°F wb entering evaporator air with 25 ft. of connecting refrigerant lines. "Denotes blower powered evaporator. "Kit is optional and must be ordered extra for field installation. f 0 RATINGS NOTE - To determine sensible capacity, leaving wet bulb and dry bulb temperatures not shown in the tables, see Miscellaneous Engineering Data, page 9. HS16-311V WITH C14-96FF FVAPnRATnR IIMIT --- • - • ••• --•--- -•� n'...,., �ar��•••�� a••� �� ..vr -`"u uvapvrator con oiower motor neat detlutai0n. HS16-311V WITH CB19-31 OR CB1-119-31 EVAPORATOR UNIT Outdoor Air Tem erature Enterin Condenser Coil °F EnteringCondenser Enter. Total 85 95 Enter. Total 105 85 115 95 Wet Air Total Comp. Sensible To Total Comp. Total Comp. Sensible 115 Total Com p' Sensible Wet Total Comp. Sensible Bulb Vol. Cool Motor Ratio Sensible To Ratio Cool Motor To Ratio Total S Cool Motor To Total Cool Motor To Total (OF) (cfm) Cap. Watts D Bulb b (O F Cap. Watts c Dr Bulb F Cap. Watts Ratio S/T °F Cap. p Watts Ratio S T (cfm) Cap. (Btuh) Input p 76 80 84 (Btuh) Input Cap. Watts Ietuhl Input D Bulb (Btuh) Input D Bulb °F Ratio (S/T (Btuh) In put p 76 80 76 80 B4 Input 76 76 1 80 1 84 (Btuh) Input 76 1 80 1 84 Input 900 31.900 2510 .76 1 .88 .99 1 30,300 2740 2990 .90 1.00 128.700 2950 .80 .93 1.00 27,000 3150 1050 1.00 63 1050 32,900 2540 .80 .93 1.00 31,200 2770 2510 .96 1.00 29 500 2990 .85 .99 1.00 27 800 3200 .83 .96 1.00 1.00 2950 1200 33,700 2560 .84 .98 1.00 31 900 2790 3070 1.00 1.00 30,300 3030 .89 1.00 1.00 28.700 3240 .88 1.00 1.00 .79 900 34,300 2580 .60 .71 .81 32.600 2820 200 .72 .83 30.700 3040 .62 .74 .86 28 800 3240 .93 .82 67 1050 35,100 2600 .62 .74 .86 33,300 2840 J.64 .76 .89 31 400 3070 .65 .79 .92 29 400 3270 .64 .77 .89 750 200 35800 2620 .65 .78 .91 33 900 2860 .69 .80 .94 31 900 3090 .68 .83 .97 29 900 3290 .67 70 .81 .95 86 1.00 .89 900 36900 2660 .45 .55 .65 35 000 2900 .83 .56 .67 33 000 3130 .46 .7 69 30 900 3350 .64 .75 .87 29 800 3300 .61 .58 .69 35 700 2920 36,200_77 .59 .71 33 600 32 100 .88 34,500 2900 .66 .47 .59 .71 32.700 1200 38 300 2690 .47 .60 .73 36 200 2940 .78 .61 .75 34,100 1 3180 1 .49 1 .63 1 .77 1131,900 .62 .75 .65 .80 1 3390 1 .48 .50 .62 .76 1 .65 .80 --- • - • ••• --•--- -•� n'...,., �ar��•••�� a••� �� ..vr -`"u uvapvrator con oiower motor neat detlutai0n. HS16-311V WITH CB19-31 OR CB1-119-31 EVAPORATOR UNIT 11 NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. HS16-311V WITH CR15-41FF FVAPnPATna IWIT Outdoor Air Temperature EnteringCondenser Enter. Coil F 95 Enter. Total 105 85 115 95 Wet Air Total Comp. 105 Total Comp. Sensible Total 115 Sensible Total Wet Air Total Comp. Sensible To Total Total Comp. Sensible To Ratio TIS S/T° Total Comp. Sensible Total Com p' Sensible Bulb Vol. Cool Motor Ratio S/T° Cool Motor To Ratio Total S/T° Watts Cool Motor To Total S/T° Cool Watts Motor To Total 1°F) (cfm) Cap. Watts Dr Bulb F Cap. Watts Dr Bulb F Cap. Watts Ratio S/T° Dr Bulb °F Cap. Watts Ratio (S/T (Btuh) In put p 76 80 84 1Btuh1 Input 76 80 76 (Btuh) Input Dr Buib F) -F -80--F-84 (Btuh) Input Dr Bulb °F 1 .87 .98 30-900 1 2770 .78 .90 1.00 129,200 2990 .80 .92 1.00 27,400 64 1.00 76 1050 33 600 2570 .80 .92 76 80 84 .82 750 30,900 2510 .73 .83 .92 29 500 2730 .74 .84 .94 28 100 2950 .76 .86 .96 26 500 3150 1.00 1.00 31,000 3070 63 950 32 700 2570 .78 .89 .98 31,300 2790 .79 .91 1.00 29 800 3020 .81 .93 1.00 28 200 3230 .78 .89 .98 1.00 .93 1150 F-34320-0 2610 .82 .94 1.00 32.700 2840 .84 .96 1.00 31.100 3070 .87 .98 1.00 29,400 3310 3290 .84 .96 1.00 1.00 36,700 750 132,800M47.67 .78 .91 68 .77 31,400 2800 .59 .69 .78 29,900 3020 .60 .70 .80 28,300 900 3230 .89 .45 .55 67 950 34,80072 .45 .56 .66 33 700 .83 33,200 2860 .62 .74 .85 31 600 3090 .64 .75 .87 29 800 3300 .61 .72 .82 .59 .70 1150 36,200_77 .47 .60 .73 32 100 .88 34,500 2900 .66 .78 .91 32.700 3130 .67 .81 .93 30 700 3340 .65 .78 .90 .63 .77 750 34 70054 .48 .50 .62 .75 .65 .80 .63 33 200 2860 .46 .55 .64 31 600 3090 .46 .56 .65 29 900 3310 .69 .83 .96 67 71 950 36 800.57 .67 35 100 2920 .47 .58 .69 33 300 3150 .48 .59 .70 31 500 3370 .46 .57 150 38 200.60 .71 36 400 2960 .49 .61 .73 34 500 3200 .49 .63 1 .75 1132,500 1 3420 .48 .50 .60 .64 .72 .78 11 NOTE - All values are gross capacities and do not include evaporator coil blower motor heat deduction. HS16-311V WITH CR15-41FF FVAPnPATna IWIT 11"L uuuucllon. HS16-311V WIT 14-41FF VAPORATOR UNIT • - --- - _ -•- ••-• -i- ..... ..vn u.uwur motor neat Ueauclion. lot - C917 SAI (, Outdoor Air Temperature Entering Condenser Coil °F Enter. Total 85 95 105 115 Wet Air Total Comp. Sensible To Total Total Comp. Sensible Total Comp. Sensible Total Comp. Sensible Bulb Vol. Cool Motor ISM Cool Motor To Ratio TIS S/T° Cool Motor To Total Cool Motor To Total (°F) (cfm) Cap. Watts Dr r B Bulb F Cap. Watts Cap. Watts Ratio S/T° Cap. Watts Ratio S/T (Btuh) Input P 76 (Btuh) Input Dr Bulb F (Btuh) Input Dr Bulb F (Btuh) Input Dr Bulb °F 76 80 84 76 1 80 1 84 76 80 84 900 32 600 2540 .76 1 .87 .98 30-900 1 2770 .78 .90 1.00 129,200 2990 .80 .92 1.00 27,400 3190 1.00 63 1050 33 600 2570 .80 .92 1.00 31 900 2800 .82 .95 1.00 30,100 3030 .85 .98 T-0-0.1128,300 3230 .82 .96 1.00 1.00 1200 34,500 2590 .84 .98 1.00 32,600 2830 .86 1.00 1.00 31,000 3070 .89 1.00 1.00 29 300 3280 .88 1.00 1.00 900 35,100 2610 .59 .70 .81 33,300 2850 .61 .72 .83 31 300 3080 .62 .74 .85 29 300 3290 .93 67 1050 36,000 2640 .62 .74 .86 34 100 2880 .63 .76 .88 32 000 3110 .65 .78 .91 30,000 3310 .63 .76 .89 1200 36,700 2660 .65 .78 .91 34,700 2900 .66 .60 .94 32 600 3130 .68 .83 .97 30 500 3340 .67 .81 .95 1.00 900 37 800 2690 ' .45 .55 .65 35 800 2940 .45 .56 .66 33 700 3170 .46 .57 .68 31 500 3390 .7 .86 71 1050 38 600 2710 46 .57 .69 36 500 2960 .47 .59 .70 34 300 3200 .47 .60 .73 32 100 3410 .47 .59 .71 NnTt: _ Ail 1200 .,oi..e� 39 300 �. ... 2730 .47 .60 .72 37 100 2980 .48 .61 .74 34 800 3220 .49 .63 .77 32 500 3430 .48 .50 .62 .75 .65 .80 11"L uuuucllon. HS16-311V WIT 14-41FF VAPORATOR UNIT • - --- - _ -•- ••-• -i- ..... ..vn u.uwur motor neat Ueauclion. lot - C917 SAI (, Qc�araaa Typical Applications Closet Installation with cooling coil and electronic air cleaner. Basement Installation with cooling coil, return air cabinet and power humidifier. 1 ENGINEERING DATA G16 AND G16X SERIES HEATING UNITS CONSERVATOR° III . GAS UP-FLO GAS FURNACES :Page s 50,000 to 125,000 Btuh Input March 1987 Add -On Cooling — 1 thru 5 Nominal Tons Supersedes April 1986 0110* o cps M b cior»rco r o ama ° aafill Aluminized Steel Heat Exchanger J f` - • v Aluminized Steel Burners Lennox G16 and G16X Series Up -Flo Gas, Furnaces Feature High Efficiency Operation and Installation Versatility The G16 and G16X series line of gas fired furnaces include seven models (natural gas or LPG) with Btuh input capacities of 50,000, 75,000, 100,000, 125,000 and energy efficiencies (AFUE) of 80% or above. Compact, rugged cabinet with either side or bottom return air entry, will allow installation in a basement, closet, recrea- tion or utility room. Optional return air cabinets are available to simplify return air duct connection to the furnace. The matching return air cabinet may be installed on either side of the furnace. Lennox add-on evaporator coils, electronic air cleaners and power humidifiers can easily be added to the furnace for a complete all season installation. Units are equipped with the gas saving automatic electronic pilot ignition system. Pilot flame is on only during main burners operating cycles. No need to shut off pilot during air conditioning season. Flue draft will -6e created by a induced draft blower mounted NOTE —Specifications, Ratings and Dimensions subject to change without notice. on the flue collector box on the outlet of the heat exchanger. The furnaces can be vented vertically as a common vent with another appliance. G16 series furnaces are design certified by A.G.A. Laboratories and ratings are certified by GAMA. Units have been rated and tested according to Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations in the Lennox Research Laboratory. G16X (natural gas) models meet the California Nitrogen Oxides (NOx) Standards and California Seasonal Efficiency requirements. Blower data is from unit tests conducted in the Lennox Laboratory air test chamber. Units are shipped factory assembled with all controls installed. Each unit is factory test -operated insuring proper operation. Installer has only to.make flue vent, gas supply and electrical connections. J C P 1= r I G I r I1C� �l lid Model No. ttG16Q2X-50 ttG16Q3X-50 ttG16Q3X-75 tt 16Q4X-75 ttG16Q3/4X-100 ttG16Q5X-100 t1G16Q4/5X-125 Rear tG16Q2-50 ' tG16Q3-50 tG16Q3.75 G16Q4-75 tG16Q3/4-100ttG16Q5-11j0tG16Q4/5-125 Floor Combustible In tit Btuh 50,000 50,000 7 ,000 75,000 100,000 ,000125,000 9.00 Output Btuh - Non "X" Models 40,000 40,000 61,000 61,000 80,000 000 100,000 tA.F.U.E. - Non "X" Models 80.1% 80.8% 80.4% 80.0% 80.0% 80.0% 80.0% Output Btuh - "X" Models 1 40,000 40,000 58,000 58,000 76,000 78,000 95,000 CA Seasonal Efficiency - "X" Models 75.1% 75.0%75.2% I 75.0% 75.3% 75.1% 72.0% Temperature rise range (°F) 35 L__65 20 - 50 35 - 65 25 - 55 35 - 65 25 - 55 35 - 65 High static certified by AGA (in, wg.) .50 .75 .50 .75 .50 .75 Flue size connection (in. diameter) 3 3 3 3 3 3 .50 Gas piping size I.P.S. (in.) nat. or LPG 1/2 1/2 1/2 1/2 1/2 1/2 3 1/2 Blower motor horsepower 1/4 1/3 1/3 1/2 1/2 3/4 3/4 Blower wheel nominal dia. x width (in.) 9 x 7 10 x 7 10 x 7 10 x 8 10 x 8 12 x 12 12 x 9 Net filter area (sq. ft.) & cut size (in.) (5.8) 36x28x1 (5.8) 36x28x1 (5.8) 36x28x1 (6.6) 40x28x1 (6.6) 40x28x1 (8.9) 52x28xl (8.9) 52x28x1 Tons of cooling that can be added 1, 1-1/2 or 2 2-1/2 or 3 2-1/2 or 3 3-1/2 or 4 3, 3-1/2 or 4 4 or 5 4 or 5 Shipping weight (lbs.) - 1 Package 160 165 170 195 205 260 270 Electrical characteristics 120 volts - 60 hertz - 1 phase (less than 12 amps) - All Models Return Air Model No. RA10-16-49 RA10-16-49 RA10-16 49 RA10.16 49 RA10-16-49 RA10-16 53 RA10-16.53 Cabinet (Optional) Shipping Wt. (lbs.) 54 1 54 54 54 54 56 56 "LPG Kit - Optional LB-55207CA (All Models) tAnnual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. (Relates to non "X" models only). 'LPG Kit must be ordered extra for field changeover. HIGH ALTITUDE DEBATE ttNot available with LPG. Units must be derated when installed at an elevation of 2000 feet or more A. G.A. INSTALLATION CLEARANCES above sea level. Table shows the derate manifold pressure for high altitude Sides 1 inch operation with both natural gas and LPG. Operating the unit at manifold pressure specified will insure proper unit heat input at hiah altitude. 'This Is clearance to all flue pipes except type "B". Type "B" vent clearance Is as listed by U.L. NOTE - Flue sizing and air for combustion and ventilation must conform to the methods outlined In American National Standard (ANSI -Z223.11 National Fuel Gas Code. iHeating value is based on an atmospheric pressure of 30 inches mercury and temperature at WF. Consult your gas utility for the local natural gas heating value. NOTE _ This is the only permissible field derate for the units. DIMENSIONS (inches) RETURN AIR CABINET ElevationManifold Above Sea Level (feet) iHeating 900 Rear 1 inch Top 1 inch Front 6 inches Floor Combustible 'Flue '4 inches 'This Is clearance to all flue pipes except type "B". Type "B" vent clearance Is as listed by U.L. NOTE - Flue sizing and air for combustion and ventilation must conform to the methods outlined In American National Standard (ANSI -Z223.11 National Fuel Gas Code. iHeating value is based on an atmospheric pressure of 30 inches mercury and temperature at WF. Consult your gas utility for the local natural gas heating value. NOTE _ This is the only permissible field derate for the units. DIMENSIONS (inches) RETURN AIR CABINET ElevationManifold Above Sea Level (feet) iHeating 900 Pressure (in. wc) Value (Btu/ft') Natural Gas 950 1000 1050 1 1100 LPG Only Sea Level - '0 4.32 3.88 3.50 3.17 2.89 9.00 1000 4.32 3.88 3.50 3.17 2.89 9.00 2000 1 3.65 3.30 2.95 2.70 2.45 7.61 3000 3.35 3.00 2.70 2.45 2.25 6.97 4000 3.05 2.75 2.45 2.25 2.14F635000 I 2.77 2.48 2.25 2.05 1.856000 I IEIrAor 2.50 2.25 2.00 1.85 1.65 1•tl2 I G16 SERIES FURNACES 17.2/ L�LUE 1.1/16 C, SUPPLY OUTLET OPENING S1/B o A B C - D E I F I G : r.I q9 i61/� 14-1/8 14 11 2-5/8 5 G16Q4(X)-75, G16Q3/4(X)-100 17.1/2 G1605(X).100, G1604/5(X)-125 53,26-1/4T2, -1/8 18 21 2.5/8 10 tlald 2,-1/2 GAS PIPING INLETS IRI hit I6o)h ddul U 2J/9 A ELECTRICAL INLETS I th.1d..I C� o r 22 2-11/16 I D RETURN AIR I OPENING I IEIrAor Lora tf _ J -_-_ I 1•tl2 I B AIRFLOW 0 ILA, .'%_ t_ -'j eC4 _ Al F " ' F Model No. ' A B C - D E I F I G G16Q2(X)-50, G16Q3(X)-50, G 16Q3(XI-75 q9 i61/� 14-1/8 14 11 2-5/8 5 G16Q4(X)-75, G16Q3/4(X)-100 49 21-1/4 19-1/814 14 3-5/8 7-1/2 G1605(X).100, G1604/5(X)-125 53,26-1/4T2, -1/8 18 21 2.5/8 10 t t NOTE - Return Air Cabinet 17.2N shipped knocked 14 RETURN AIR - down and must be OPENING field assembled. 0 A �_ I I z 22 1 ' e RETURN AIR I KNOCKOUT (both sides) L- -------� 1.1R Model No. RA10-16-49 RA10-16-53 `q _ qg 53 B 14 ' 18 . BLOWER DATA .131612(X)-50 BLOWER PERFORMANCE G16Q3(X)-50 BLOWER PERFORMANCE External Static Pressure (in. w .) Air Volume High (cfm) @ Various Medium Speeds Low 0 1240 980 600 -.05 1225 975 602 .10 1205 975 605 .15 1185 970 605 .20 1165 , 970 605 .25 1140 965 600 .30 1115 955 595 .40 1060 930 580 .50 990 875 550 NOTE -. Al m is measured ext e nal to the unit with the air filter In place. 1613(X)-75 OWER PERFORMANCE External Static .. Pressure ' (in. w .) Air High Volume (cfm) @ Various Speeds Med-High Med-Low Low 0 1560 1265 1055 910 .05 1540 1250 1047 910 .10 1510 1240 1040 907 .15 1485 1225 1036 905 .20 1455 1215 1025 900 .25 1425 1200 1015 895 .30 1850 8 1420 885 .40 1 1325 1145 97069, 1125 .50 1245 1090 925 81 ' •� 1625 1410 1265 700 d High .. 01. 1980 1715 1460. NOTE - All cfm is measured external to the unit with the air filter in place. .05 G16Q3/4(X)-100 BLOWER PERFORMANCE 1695 External Sfatic Air Volume (cfm) Various Speeds 1145 .10 1960 1680 � Pressure (in. w .) High @ Med-High Med-Low Low 01. 1980 1715 1460. 1145 .05 1970 1695 1455 1145 .10 1960 1680 1445 1140 .15 . 1940 1660 1440 1140 .20 1910 1640 1435 1140 .25 1880 1615 1430 1135 .30 1850 1595 1420 1130 .40 1 1780 1545 1395 1125 .50 1710 1480 1330 1100 .60 1625 1410 1265 1030 .70 1520 1325 1190 940 .80 1410 1230 1100 835 erg External Static Pressure (in. w .) Air FHighTMed-High Volume (cfm) @ Various Speeds Med-Low Low 0 1585 1320 1100 945 .05 1575 1310 1095 940 .10 1560 1300 1087 935 .15 1535 1285 1080 930 .20 1510 1265 1070 925 .25 1480 1245 1060 920 .30 1445 1225 1045 910 .40 1380 1175 1015 890 .50 1300 1125 980 855 .60 1205. 1070 905 800 .70 1080 1025 780 700 NOTE - All cfm Is measured external to the unit with the air filter in place. . G16Q4(X)-75 BLOWER PERFORMANCE External Static Pressure • (in. wg.) Air Volume High (cfm) @ Various Medium Speeds Low 0 1815 1420 1130 .05 1790 1415 1145 .10 1765 1410 1155 15 1740 1405 1160 .20 1715 1402 1160 .25 1680 1395 1155 .30 1655 1390 1150 .40 1590 1365 1130 .50. 1500 1325 1110 .60 1355 1230 1090 .70 1165 1100 1065 IVU I E - All cfm Is measured external to the unit with the air filter in place. G16Q5(X)-100 BLOWER PERFORMANCE External Static Pressure (in. wg.) Air Volume (cfm) @ Various Speeds High Med-High Medium Med-Low Low 0 2835 2550 2290 1945 1700 .05 2820 2535 2275 1930 1690 .10 2790 2515 2265 1910 1675 .15 2760 2495 2230 1895 1650 .20 2740 2475 2210 1875 1630 .25 2700 2450 2185 1860 1615 .30 2670 2435 .••2160 1840 1595 .40 2600 2390 2110 1800 1550 .50 2535 1 2340 2050 1750 1500 .60 2450 1 2280 1985 1700 J450 .70 2380 2210 1910 1645 1390 .80 2290 2130 1830 1580 1310 NU IF -All cfm Is measured external to the unit with the air filter In place. NOTE - All cfm Is measured external to the unit with the air filter in place. G16Q4/5(X)-125 BLOWER PERFORMANCE External Static Air Volume (cfm) @ Various Speeds Pressure (in High Med-High Medium Med-Low Low wg) 0 2535 2290 2040 1800 1590 05 2510 2270 2025 1790 1575 .10 2490 2250 2010 1775 1560 .15 2465 2225 1990 1760 1540 .20 2435 2200 1970 1740 1525 .25 2405 2175 1940 1720 1500 .30 2370 2145 1915 1695 1480 •40 2305 2085 1860 1645 1440 •50 2235 2020 1800 1585 1390 60 #207 NOTE - All cfm is measured external to the unit with the air filter in place. - ink - 1940 ' '1725 1525 1340 70 ; 1850 1640 1460 1220 80 1750 1550 1390 1215 External Static Air Volume (cfm) @ Various Speeds Pressure (in High Med-High Medium Med-Low Low wg) 0 2535 2290 2040 1800 1590 05 2510 2270 2025 1790 1575 .10 2490 2250 2010 1775 1560 .15 2465 2225 1990 1760 1540 .20 2435 2200 1970 1740 1525 .25 2405 2175 1940 1720 1500 .30 2370 2145 1915 1695 1480 •40 2305 2085 1860 1645 1440 •50 2235 2020 1800 1585 1390 60 #207 NOTE - All cfm is measured external to the unit with the air filter in place. - ink - 7 • ©. Thirmal Mass Worksheet ws=11t traject rale .. � lj . q U —' bite IN!-ERIOR T* HERMAL MASS Use one of the two following options for calculating Interior mass as explained in Section 4.2 of file Energy Con.tervatlon Manual (ECAf). Method 13 must be used for mass elements that have an Interior unit mass capacity Iess.than 1.7. Method A: Look up the Interior Mass/CFA valve from ECAf Table 4-7 rcprhttcd on the reverse sldc of this page. 1 ypc 1 mass has a Unit Interior Mass Capacity (UIMC) greater than or equal to 4.2 (sec ECM l,ablcs 4 8I and 4his rcprintcd on divide Attachment). c Type 2 mass has a UIMC greater than or equal to 1.7 and less titan 4.2. Mass % is Ure mass surface are, ' divided by conditioned floor arca (CrA). For mass elements exposed on both (two) sides to conditioned space, enter the arca of only one side to calculate lite percentage. '1'ypc 1 Mass Area: Mass % Type 2 Mass Arca: Inlerior Mass/CFA frorn Table 4-7: 1,7 Alelhod 11: Calculate the Interior Mass/CFA value using Ute �'vorksheel Space helow. Look 11P the Unit Interior Mass Capacity N11�1C) for c��ch interior mass surface in ECAf Tnbles 4 -81.4 -Bb and 4-9 reprinted on the Attachment. Include the b Interior surfaces of exterior mass walls. For interior mass walls exposed on bout surface area of only one side. Include the Inside surfaces of exterio(two) sides to conditioned space, enter the r mass walls as explained in Section 4.2 of the ECM. Unit Interior Interior Description Mass Area Mass Capacity Mass Capacity X X X X . x — hota�— CFA Interior 1~iv ass/CIU EXTERIOR WALL THERMAL MASS Calculate the Exterior Wall Miss of all exterior walls. Look up the Exterior Mass Factor for each opaque wall clement from ECM Tabic 4-9 reprinted on Ute Attachment. Only exterior mass wall surfaces may be included In flus calculation, Opaque Exterior Description. Wall Arca Mass Factor X X Conventional Tails x 0 _ 7b1a1— q alai U—pa que Wall Arca Corm Revised March 1988 Exlcnor Wall Mass Mandatory Measures Checklist: Residential MF -IR NOTE: Lowrise residential buildings subject to the Standards must contain then.^. measures regardless of the compliance approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements listed pn the Certificeu of Compliance. When this chocklist Is incorporated Into the permit documents, the features noted shall be considered by.all pardes aminimum component binding minimucomponent performance specrGcations for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION Building Envelope Measures • 12.5352(a):. Minimurn ceiling insulation R-19 weighted average. 12-5352(b): Loose fill insulation manufacturer's labeled R•Value- • 12.5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). 12.5352(kr Slab edge insulation - water absorption rate no greaser than 0.396, wat.a vapor transmission rate no greater than 2.0 perrn/mch. 12-5311: Insulation specified or installed meets California Energy Commission (CEC) quality standards. Indicate type and form. 12-5352(rr Vapor barriers mandatory in Climate Zones U and 16 only. ' 12-5317: lnfiltratloNEufdtration Controls a a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doan and windows certified. t Doors and windows weatherstripped: all joins and penetrations caulked and sealed. 12-5352(c): Special infdnm adon tamer installed to comply with 12-5351 meets CEC quality sundmd12-5352(d): installation of Freplaeos 1. Masonry and factory -built fireplaces have a Tight filling, closeable metal or glass door b. Outside air intake with damper and control e. Flue damper and control 2. No continuous burning gas pits allowed. HVAC and Plumbing System Measures 12-5352(g) and 2-5303: Space cohditioning equipment siring: attach alculations. 12-5352(h) and 2-5315: Setback Uherawstat on all applicable heating systems. 12.53166): Ducts constructed. installed -and insulatod per Chapter 10, 1976 UMC. 12-5316(br Exhaust systems have damper controls. 12-5314(c): Gas -fund space hating equipment has intermittent Ignition devices. 12-5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. §2-5352(1): Water heater insulation blanket (R-12 or grater) or combined interior/exterior insulation (R-16 or greater): first 5 feet of pipes closest to lank insulated (R-3 or greater). 12.5312(Exception A: Pipe insulation on steam and steam condensate return At recirculating. piping. 12-5318(d): Swimming Pool Hating 1. System has: a. On/off switch on hater. b. Watherprouf instruction plate on hater. C. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. S. Directional water inlet. Lighting and Appliance Measures 12.53520; Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. 12-5314(c): Gas fired appliances equipped with intermittent ignition devices. 12.5314(8): Refrigerators, refrigerator -(recurs, frteaers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. T4ble C-9: Shag;nB Co�l-,clenu forlnterW Shnding Devices Double Not Noon O.bd 0.75 033 Obi 033 Ckar Ctua Men! 0.77 0.66 0.48 036 029 Wood 0.67 037 0.42 0 49 023 Ta61r 4.11: IWAC Duct Firlrnry, Factors One Story Buildings: Duct Attic Vented Crawl Spate R -Value Heating Cooling Heating Cooling 2.1 .78 .74 .78 .84 41 .82 .81 .82 .86 6.3 .84 .83 .84 .87 Tin- ondThreeStory Bulld(nts: Duty Attic Vaud Crawl Space R -Value Hating Cooling Heating Cooling 2.1 .85 .83 .85 89 . 4.2 .88 .87 88 .91 6.7 90 .s9 .90 .91 SC . (S� SC(Sxae.Cror.0 CttrinITrpt R•amina Ct. Droperyr Vtntd-811.drU 0o1r N00 -h hel WLkd ' OrrWtit" Medlin IkM4 (SoLrRefL) (01[Ax) (0.4m30) (030) . (0.70) Static tont Clew MASS None Ment 1.00 0.88 0.91 0.62 - 0.80 OSS 0.73 034 Wood 0.76 0.69 0.47 0.64 0.30 033 016 Double Not Noon O.bd 0.75 033 Obi 033 Ckar Ctua Men! 0.77 0.66 0.48 036 029 Wood 0.67 037 0.42 0 49 023 Ta61r 4.11: IWAC Duct Firlrnry, Factors One Story Buildings: Duct Attic Vented Crawl Spate R -Value Heating Cooling Heating Cooling 2.1 .78 .74 .78 .84 41 .82 .81 .82 .86 6.3 .84 .83 .84 .87 Tin- ondThreeStory Bulld(nts: Duty Attic Vaud Crawl Space R -Value Hating Cooling Heating Cooling 2.1 .85 .83 .85 89 . 4.2 .88 .87 88 .91 6.7 90 .s9 .90 .91 Certificate of Compliance: Residential Climate Zone 11 - ' f Project Title Building Permit # t Project Address ; Chocked By/ Date Documentation Author - Telephone Enforcement Agency Use Only t Glass Area 9b Glass BUILDING DATA North Conditioned Floor Area Number of Stories East - Slab/Raised Floor Number of ,Units South [ ] Single Family Detached (SFD) [ ] Addition Alone West [ ] Single Family Attached (SFA) __ [ ] Existing Building Skylight [ ] Multi -Family (NM [ ] Existing -Plus -Addition Tom BUILDING SHELL INSULATION - Component Insulation Locatilon/Comments Type R -Value (attic, .ter garage, tai: al, etc.) ; Wall .............. Wall ............. ! Roof ............. i Roof ............. Floor ............. Floor ............. : Slab Edge..... GLAZING Shading Devices Glazing Area Glass Type Interior Exterior Overhang Framing Type Orientation (sf) (single, double) (Toiler blind. etc.) (shlltiescreen, etc.) (yes/no) (metal/wood) North ( ) North ( ) East East ( ) South SOUth - . West ( ) West ( ) Skylight....... THERMAL MASS I Type/Covering Area Thickness (slab/exposed, rite, etc.) 00 (inches) Locatiorl/DCSCription(kitchen. bath. etc.) 1 i HVAC SYSTEMS Minimum Duct 1 j Type (furnace, air Efficiency Location Duct Output Manufacturer / Model # conditioner, heat pump) (SE, SEER,HSPF) (attic, etc.) R -Value (Btuh) (or approved equal) I i Maximum Furnace Heating Output: Btuh I 1 HOT WATER SYSTEMS Tank Manufacturer/Model # i System Type (storage gas, etc.) Capacity (or approved equal) Special Feature(s) 1 SPECIAL FEATURES/REMARKS (Add extra sheets if necessary) l - 1 Mandatory Measures Checklist: Residential MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the mnpliance approach used Items marked with an asterisk (•) may be superseded by more stringent complw= requuements fisted on the Certificate of compliance. Wben this checklist is incorporated into the permit documents. the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they arc shown elsewhere in the documents or on -this checklist only. DESCR1P ION Building Envelope Measures §2.5352(a): Minimum ceiling insulation R-19 weighted average. §2.5352(b): Loose fill insulation manufacturer's labeled R -Value. . §2-5352(c): Minimum wall insulation in framed walls R-11 weighted average (does not apply to exterior mass walls). §2-5352(k)-. Slab edge insulation - water absorption rate no greater than 0.3%. water vapor transmission rate no greater than 2.0 permfinch. §2-5311: Insulation specified or installed meets California Energy Commission (CM quality standards Indicate type and form. §2.5352((): vapor barriers mandatory in Climate Zones 14 and 16 only. §2-5317: Infiltration/Exfilt ation Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit ,it leakage. b. Doors and windows certified. c. Doors and windows weatherstripped; all joints and penetrations caulked and Baled. §2-5352(e): Special infiltration barrier installed to comply with §2-5351 meets CEC quality standards. §2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have a. Tight fitting, closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. HVAC and Plumbing System Measures 52-5352(8) and 2-5303: Space conditioning equipment sizing: attach calculations. §2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. • §2-5316(a): Ducts constructed. installed and insulated per Chapter 10. 1976 UMC. §2-5316(b): Exhaust systems have damper controls. §2-5314(c): Gas -fated space heating equipment has intermittent ignition devices. §2-5314: HVAC equipment, water heaters. showerheads and faucets certified by the CEC. §2.5352(1): Water heater insulation blanket (R-12 or greater) or combined interiorlcxterior insulation (R-16 or greater): fust 5 feet of pipe closest to tank insulated (R-3 or greater). §2-5312(Excep6on 1): Pipe insulation on steam and steam condensate rerun & recirculating piping. §2-53 18(d): Swimming Pool Heating I. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater: c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet Lighting and Appliance Measures ' §2.53520): Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. §2-5314(c): Gas fired appliances equipped with intermittent ignition devices. §2.5314(a): Refrigerators, refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. COMPLIANCE STATEMENT DESIGNER I ENFORCEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title 24. Chapter 2-53 and Title 20, Chapter 2. Stibd upter 4. Article I of the California Administrative code This certificate has been signed by the individual with overall design responsibility and the building owner. who shall retain a copy of it and transmit the certificate to any subsequem purllaser of the building. Designer Name: Titk/Futn: Address: Tekpion= Uc. 0: ( (date) Documentation Author Name: rtwFirma Address: Building Owner Name Tide/Finn. Address: Telephone: (signature) (date) Enforcement Agency Name: Agency: Tekphone J. Ceiling Insulation R -value R-0 R-19 R30 R-38 U -value 0.50 0.30 0.10 0.08 0.06 0.04 0.02 0.00 One -103 -8 -2 0 -176 -102 -26 -18 -11 -4 4 11 Number of stories Two -49 -4 -1 0 -84 -49 -13 -9 -5 -2 2 5 Three -32 .2 -1 0 -54 32 -8 -6.. . -4 -1 1 3 2. Wall Insulation -144 1 -46 Single Single - -58 38 Family Family Multi - R -value Detached Attached Family R-0 -68 -51 -34 R-11 0 0 0 R-13 2 2 1 R-19 8 6 4 U -value -2 0.04 -1 0.80 -153 -114 -76 0.50 -91 -68 -46 0.30 -47 -36 -24 0.10 0 0 0 0.08 4 3 2 0.06 9 7 5 0.04 14 11 7 0.02 19 14 10 0.00 24 18 12 3. Raised Floor Insulation -- 25 Insulation in Floor -14 R -value One Number of stories Three R -value One Two Three R-0 -17 -8 -5 R-11 -3 -2 -1 R-19 0 0 0 R-30 3 1 1 U -value -4 3 .1 0.80 -1 -144 -70 -46 0.50 -120 -58 38 0.40 -95 -46 30 0.30 -69 -34 -22 0.20 -43 -21 -14 0.10 -17 -8 -5 0.08 -11 -6 -4 0.06 -6 -3 -2 0.04 -1 0 0 0.02 4 2 1 0.00 10 5 3 Controlled Ventilation Crawlspace -58 -20 Number of stories -3 R -value One Two Three R-0 -11 -7 -5 R-5 -4 -4 3 R-11 -2 -2 .2 R-19 -1 -2 2 4. Slab Edge Insulation 7 -- 25 Number of Stories -14 R -value One Two Three ' R-0 0 0 - 0 R-5 8 5 2 R-7 8 6 3 F2 factor 0.90 -4 3 .1 0.80 -1 -1 0 0.70 2 2 1 0.60 6 4 2 0.50 9 6 3 0.40 12 8 4 S. Infiltration (Air Leakage) specification Points Standard 0 6. Glass Heat Loss Total -14 -48 -69 -64 U -value East Percent :West Skylight .51 to .41 to .31 to 0.30 or Glass Single Double .60 .50 .40 less 50 -121 -53 -39 -24 -10 4 40 -90 37 -26 -14 3 8 1 35 -75 -29 .19 -9 1 10 30 -61 -21 -13 -4 4 12 1 29 -58 -20 -12 -3 5 12 28 -55 -18 -10 -2 5 13 27 -52 -17 -9 -2 6 13 26 -49 -15 _8 -1 7 14 25 -46 -14 -7 0 7 14 24 -43 -12 -5 1 8 14 23 -40 -11 -4 2 8 15 22 37 -9 -3 3 9 15 21 34 -7 -2 4 10 15 20 31 -6 0 5 10 16 19 -29 -4 1 6 11 16 18 -26 3 2 7 12 16 17 -23 -1 3 8 12 17 16 -20 0 4 9 13 17 15 -17 1 6 10 14 17 14 -14 3 7 10 14 18 13 -12 4 8 11 15 18 12 -9 6 9 12 15 19 11 3 7 10 13 16 19 10 3 9 it 14 17 19 9 -1 10 13 15 17 20 8 2 12 14 16 18 20 0.95 8.71 20 18 15 13 11 8 1 Effective SE or HSPF 24 7..Shading (Shade Open) Ef ectli a Percent Glass (percent Stas x SC) Effective -14 -48 -69 -64 %Glass North East South :West Skylight 18 5 1 4 1 na 16 4 2 5 1 na 14 4 2 5 1 na 12 3 3 5 2 na�' 11 3 3 5 2 na 10 2 3 5 2 1 9 2 3 5 2 2 8 2 3 5 2 2 7 1 3 4 2 2 6 1 3 4 2 3 5 1 2 4 2 3 4 0 2 3 1 3 3 0 1 2 1 3 2 0 0 1 0 3 1 -1 -1 -1 -1 2 0 -1 -2 -4 -2 0 na = not allowed 2 3 4 .3 lB. Shading (Shade Closed) F7fecdve Percent Glass (Percent glass x SC) Effective %Glass North Emut South West Skylight 18 -14 -48 -69 -64 na 16 -12 -42 -59 -55 na 14 -10 -35 -50 -46 na 12 -8 -29 -40 37 na 11 -7 -26 36 -33 na 10 -6 -23 31 -29 -74 9 -5 -20 -27 -25 -65 8 -5 -17 -23 -21.. -56 7 -4 -14 -19 -18 -47 6 -3 -11 -15 -14 38 5 -2 -9 -11 -10 -30 4 -1 3 -8 -7 -23 3 0 -4 -5 -4 -16 2 1 -1 -2 -1 -9 9 10 12 13 13 7.0 6 1 -4 0 2 3 4 .3 0 na . rat allowed 9. Interior Thermal Mass or Intirior Slab Floor Raised Floor Mass Stories Stories ICFA One Two Three One Two Three 0.0 -8 -5 -4 -2 -1 -1 0.1 -8 -5 -3 -1 0 0 0.3 -7 -4 -2 0 1 1 0.5 -6 3 -1 1 1 2 0.7. -5 -2 -1 1 2 2 0.9 -5 -1 0 2 3 3 1.1 -4 -1 1 3 4 4 1.3 -3 0 2 3 4 5 1.5 -3 1 2 4 5 5 20 -1 2 4 5 6 7 25 0 3 5 7 7 8 3.0 1 4 6 8 8 9 3.5 2 5 7 9 9 10 4.0 3 6 8 9 10 10 4.5 3 7 8 10 11 11 5.0 4 7 9 11 12 12 5.5 5 8 9 11 12 12 6.0 5 8 10 12 13 13 6.5 6 9 10 12 13 13 7.0 6 9 11 13 13 14 7.5 6 10 11 13 14 14 8.0 7 10 11 13 14 14 8.5 7 10 12 13 14 15 10. Exterior Wall Thermal Mass Effective -25 or Exterior Wall Single- Single. +6 to 16 or SEER Family Fanuly Multi +5 Mass Detached Attached Family 0.00 0 0 0 -13 0.20 3 2 1 -11 -9 0.40 5 4 3 6.6 0.60 8 6 4 .-2 0.80 10 8 5 0 0 1.00 13 10 7 8.0 1.20 13 12 8 4 1.40 12 13 9 14 12 1.60 10 13 11-- 10.0 1.80 10 12 12 10 200 10 11 _ 13 i 11. Heating System 12 8 12.0 SE or ASPF 26 22 18 (assumes ducts In attic) 9 13.0 33 Sum of 13 20 15 10 -25 or -24 to -14 to -4 to +6 to 16 or SE HSPF less -15 -5 . +5 +15 more 0.72 6.60 0 0 0 0. 0 0 0.75 6.88 3 3 3 2 2 1 0.80 7.33 8. 7 6 5 4 3 0.85 7.79 13 11 10 8 7 5 0.90 8.25 17 15 13 11 9 7 0.95 8.71 20 18 15 13 11 8 1 Effective SE or HSPF 24 (SE or HSPF x duct efficiency) Unit Size (sQ Effective -25 or -24 to -14 to -4 to +6 to 16 or SE HSPF less -15 -5 +5 +15 more 0.30 275 -73 -64 -56 -47 -38 -30 na 3.41 -45 -39 -34 -29 -24 -18 0.40 3.67 -34 -30 -26 -22 -18 -14 0.50 4.58 -10 -9 -8 -7 -5 -4 0.56 5.13 0 0 0 0 0 0 0.60 5.50 5 5 4 3 3 2 0.70 6.42 17 15 13 11 9 7 0.80 7.33 25 .22 19 16 13 10 0.90 8.25 32 28 24 20 17 13 1.00 9.17 37 32 28 24 19 15 Zonal Control Adjustment 8 5 System Type 3 3 SE Resistance 10 '9 7 6 4 3 Other 6 5 4 3 2 2 1 12. Cooling Syst.!m F or R -value 1381 SEER or (assumet ducts In attic) Interior Mass/CFA U -value [0.0981 Stm of 7-10 or -25 or .24 to r-14 b -4 to +6 to 16 or SEER less. -15 D •6 +5 +15 more 8.0 -14 -12 -10 -8 -6 -4 . 8.5 -9 -7 -6 -5 -4 3 o 8.9 -5 -4 -4 3 -2 -2 9.0 -4 3 -3 -2 .2 -1 9.5 0 0 0 0 0 0 10.0 .4 3 3 2 2 1 10.5 7 6 5 4 3 2 11.0 10 9 7 6 4 3 120 15 13 11 14 9 12_ 7 9 5 6 13.0 20 17 .., 9t7% 95% 100% 105% 110y. 116% 120% 125` OY. 0 Effective SEER 0.4 0.6 0.8 (SEER xduet efficiency) 1.3 1.5 1.7 Sim of 7-10 21 23 Effective -25 or -24 to -1410 -410 +6 to 16 or SEER less -15 t -6 +5 +15 more 5.0 30 -25 -21 -17 -13 -9 i 6.0 -12 -11 -9 -7 -6 4 6.6 -5 -4 -4 -3 .-2 -2 7.0 0 0 0 0 0 0 8.0 9 8 6 5 4 3 9.0 16 14 12 9 7 5 10.0 22 19 16 13 10 7 11.0 26 23 19 15 12 8 12.0 30 26 22 18 14 9 13.0 33 29 24 20 15 10 0.9 Zonal Control Adjustment 1.4 1.6 1 10 8 7 6 4 3 3 No Cooling System Installed i I -Stories 4.1 4.3 4.5 4.7 4.9 One -5 -4 -4 3 -2 -2 Two + 3 3 2 2 2 1 Single•Famlly Detached and Attached 24 26 Unit Size (sQ 3 Water 3.4 i 139 i 1200 1700 2200 2700 Heater Credit or b to to or Type Type loss i16N 2199 2699 more SG None 0 i.' 0 0. 0 0 or Solar 12 " 8 6 5 4 HP HWR $ 5 4 3 3 5.3 WSB 5 3 3 2 2 0.9 POU 8 5 4 3 3 SE None -37 -24 -18 -15 -12 3.S Solar -1 -1 -1 0 0 4.7 HWR -18 -12 -9 -7 -6 6 WSB . -25 -16 -12 -10' -8 1.7 POU -18 _-12 -9 _7 -6 -IG None "-5 -3 -2 -2 '-2 4.2 Solar 7 5 -4 3 2 5.4 POU 3_ 2 1 1 1 IE None -28 -19 -14 -11 -9 2.4 Solar 8 5 4 3 3 3.6 POU -10 -6 -5 -4 -3 4.9 Multi -Family (Individual units) 5.3 5.5 5.7 Unit Size (SO 6.1 6.4 Water 1.2 699 700 1200 1700 2200 Heater Credit or b to b or Type Type less 1199 1699 2198 more SG None _ 0 0 0 0 0 or Solar 14 7 5 4 3 HP HWR 9 5 3 2 2 3 WSB 9 4 3 2 2 4.2 POU 9 5 3 2 2 SE None -45 -23 -15 -11 .9 801/6 Solar 2 1 1 0 0 2.4 HWR -23 -12 -8 3 '.5 3.7 WSB -25 -13 -8 -6 -5 _e4U 5.1 _23 _12 -8 -6 -5 IG None -8 4 -3 .2 -2 1.9 Solar 6 3 2 1 1 3.1 POU 1 0 0 0 0 IE None 3 -15 _0 -10 - ' -8 -6 . 5.6 Solar 18 9 6 4 4 WY. •" POU -8 . -4 -3 -2 .2 Point System Summary: Climate Zone 11 SCORE CARD Measures 1. Ceiling Insulation 2. Wall Insulation 3. Raised Floor Insulation 4. Slab Edge Insulation S. Infiltration 6. Glass Heat Loss 7. Shading (Shade Open) a. North b. East c. South d. West e. Skylight 8. Shading (Shade Closed) a. North b. East c. South d. West e. Skylight 9. Interior Thermal Mass 10. Exterior Wall Mass 11. Heating System Zonal Control? ( Y / N ) 12. Cooling System Zonal Control? ( Y / N ) 13. Water Heating Point Scores or R -value 1381 U -value 10.0301 or R -value [ 111 Interior Mass/CFA U -value [0.0981 or R -value 119] • rr►e = wits Or R -value (01 F2 factor [0.77) Standard 0 U -value 10.65] %Total Glass (16) Sum 1-6 Type [double] °lo Glass Sc Eff. % Glass X = ti."uiuc•4.=' Ie•rvet60 •l.el X = • X = t TYPE 1 MASS WINC a 4.2, le: exposed slab) X = • Glass SC Eff. % Glass 0% 5% 10% 15% 20% 2S% 30% 35% 40% 45% 50% 55% 60% SS46 70% 75% 80% 8575 9t7% 95% 100% 105% 110y. 116% 120% 125` OY. 0 0.2 0.4 0.6 0.8 1.1 1.3 1.5 1.7 1.9 21 23 25 2.7 2.9 3.2 9.4 3.8 3.8 4 4.2 4.4 - 4.6 4.8 5 5.3 101/6 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.9 21 2.3 25 2.7 2.9 3.1 3.3 3.5 3.7 4 4.2 4.4 4.6 4.8 5 5.2 5.4 20% 0.3 0.6 0.8 1 1.2 • 1.4 1.6 1.8 2 2.2 24 27 29 3.1 3.3 3.5 3.1 3.9 4.1 4.3 4.5 4.8 5 5.2 5.4 56 30% O.S 0.7 0.9 •1.1 1.4 1.6 1.8 2 22 24 26 28 3 3.2 3.5 3.7 SA 4.1 4.3 4.5 4.7 4.9 5.1 5.3 5.6 5.8 40Y. 0.7 0.9 1.1 1.3 1.5 ,1.7 1.9 2.2 24 26 2.8 3 3.2 3.4 3.6 3.8 4 4.3 4.5 4.7 4.9 5.1 5.3 5.5 5.7 5.9 50Y. 0.9 1.1 1.3 1.5 1.7 1.9 21 23 25 27 3 32 3.4 3.6 3.8 4 42 4.4 4.6 4.8 5.1 5.3 5.5 5.7 5.9 6.1 SS% 0.9 1.1 1.4 1.6 1.8 2 2.2 24 2.6 28 3 32 3.S 3.7 3.9 4.1 4.3 4.S 4.7 4.9 5.1 5.3 5.6 S.8 6 6.2 60% 1 12 1.4 1.7 1.9 21 23 2.5 2.7 29 3.1 3.3 3.5 3.8 4 4.2 4.4 4.6 4.8 ' S 5.2 5.4 5.6 5.9 6.1 63 65% 1.1 1.3 1.5 1.7 1.9 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6 3.8 4 4.3 4.5 4.7 4.9 5.1 5.3 5.5 5.7 5.9 6.1 6.4 701/6 1.2 1.4 1.6 1.8 2 22 2.S 27 2.9 3.1 3.3 3.5 3.7 3.9 4.1 4.3 4.6 4.8 S 5.2 5.4 5.6 58 6 6.2 64 75% 1.3 1.5 1.7 1.9 21 23 25 2.7 3 3.2 3.4 3.5 3.8 4 4.2 4.4 4.6 4.8 5.1 5.3 5.5 5.7 5.9 6.1 6.3 6.5 801/6 1.4 1.6 1.8 2 2.2 2.4 26 2.8 3 3.3 3.5 3.7 3.9 4.1 4.3 4.5 4.7 4.9 5.1 5.4 5.6 5.8 6 6.2 64 66 85% 1.4 1.7 1.9 2.1 2.3 25 2.7 2.9 3.1 3.3 3.S 3.8 4 4.2 4.4 4.6 4.8 S 5.2 S4 5.6 5.9 6.1 6.3 65 67 WY. •" 1.5 1.7 2 2.2 24 26 2.8 3 3.2 3.4 3.6 3.8 4.1 4.3 4.5 4.7 4.9 5.1 53 5.5 5.7 5.9 6.2 6.4 66 68 95% 1.6 1.8 2 2.2 2.5 27 2.9 3.1 33 3.5 3.7 3.9 4.1 4.3 4.6 4.8 S 5.2 5.4 5.6 5.8 6 6.2 6.4 6.7 6.9 100% 1.7 1.9 21 2.3 25 28 3 3.2 3.4 3.6 3.8 4 4.2 4.4 4.6 4.9 5.1 5.3 55 5.7 5.9 6.1 6.3 6.5 6.1 7 105% 1.8 2 22 2.4 2.6 28 3 3.3 31 3.7 3.9 4.1 4.3 4.5 4.7 4.9 5.1 5.4 5.6 S.8 6 6.2 6.4 6.6 68 7 110Y. 1.9 2.1 2.3 2.5 27 29 3.1 3.3 3.8 3.8 4 4.2 4.4 4.6 4.8 5 5.2 5.4 5.7 5.9 6.1 6.3 6.5 6.7 69 7.1 115% 2 2.2 2.4 2.62.8 3 3.2 3.4 3.6 3.8 4.1 4.3 4.5 4.7 4.9 5.1 5.3 5.5 5.7 5.9 6.2 6.4 '6.6 6.8 7 7.2 120% 2 2.3 2.5 2.7 2.9 3.1 3.3 3.5 3.7 3.9 4.1 4.4 4.6 4.8 S 5.2 $.4 5.6 58 6 6.2 6.5 6.7 6.9 7.1 7.3 125% 21 23 25 2.8 3 3.2 3.4 3.6 3.8 4 4.2 4.4 4.6 4.9 5.1 5.3 5.5 5.7 5.9 6.1 6.3 6.5 6.7 7 7.2 7.4 Point System Summary: Climate Zone 11 SCORE CARD Measures 1. Ceiling Insulation 2. Wall Insulation 3. Raised Floor Insulation 4. Slab Edge Insulation S. Infiltration 6. Glass Heat Loss 7. Shading (Shade Open) a. North b. East c. South d. West e. Skylight 8. Shading (Shade Closed) a. North b. East c. South d. West e. Skylight 9. Interior Thermal Mass 10. Exterior Wall Mass 11. Heating System Zonal Control? ( Y / N ) 12. Cooling System Zonal Control? ( Y / N ) 13. Water Heating Point Scores Type [SG] Credit [none] Point Total: or R -value 1381 U -value 10.0301 or R -value [ 111 U -value [0.0981 or R -value 119] U -value [0.0371 Or R -value (01 F2 factor [0.77) Standard 0 U -value 10.65] %Total Glass (16) Sum 1-6 Type [double] °lo Glass Sc Eff. % Glass X = X = X = X = X = • Glass SC Eff. % Glass X = X X = X = X = TYPE 1 MASS AREA % COND. FLOOR AREA InteriorMrlss/CFA TYPE 2 MASS AREA __ $ Exterior Wall Mass COND. L OR AREA Sum 7-10 X SE or HSPF Duct Efficiency 10.781 Effective SE or [0.72/6.6] HSPF 10.56/5.15] X = SEER 19.51 Duct Efficiency [0.74] Effective SEER [7.03] Type [SG] Credit [none] Point Total: