Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
069-580-050
069-58-0-050 0p���24� PRATER, RON �t IS REGAL WAY, OROVILLE 'a'a4•oo CONT: R.D. PRATER CONST. CO. NEW SINGLE FAMILY T NOTES 'I RESIDENTIAL i j 069-58-0-050 00-1124 { PERMIT NO. _ PRATER, RON I _i . . _ _ _ _ j r 18 REGAL WAY, OROVILLE f CONT: R.D. PRATER CONST. CO. NEW SINGLE FAMILY- f SPECIAL CONDITIONS CHECKED BY SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER i OFFICE COPY M Address / /1 GAS Meter By Date i MeE`t-E� ate 4 Qdpt _� er By ELECTRIC Meter By Date*, 21 r 4 JOB FINALED (Date)Z//0,6 Signature ,.� ✓ = OK 0 = Not OK - = Not Applicable MOBILE HOMES ., = Not Ready, Date ' MOBILE HOME UTILITIES (Plans) OK except #'s 2. 1. Zoning Requirements -Setbacks -Easements 3. 2. Soils; Special MH Support Sketch 4. 8. Sewer; Location -Test -Fall -C/O -Concrete 5. 4. Water; Location -Test -Easement Needed (Sketch) 6. 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 7. 6. Gas; Location -Test -Wrap;-/ /" L'ft. / P Nat. or / /"L"ft./ /'LPG 8. 7. Well Clearance 8 Disconnect 9. 8. Utility Clearance 10. Exits; Insp.-Sketch 11. Cert, of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert, of Occupancy 12. Permanent Foundation Only; License Decal Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card 8-1 Date Card B-1 Date Card B-1 , MISCELLANEOUS Date DECKS, COVERS, CARPORTS GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rhrs.-Connectors Shthg.-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI. 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Pane lboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card 8-1 Date Card B-1 Date Card B-1 V=OK 0 = Not OK - = Not Applicable = Not Ready RESIDENTIAL (; Date erfloor (Plans) OK except #'s Zo g-Setbacks-Easements-Flood- tg. Main; Soils-EIe rn tg. Depth Garage; Soils-Steel-Elec. Grnd. 'tg. Depth 4. Fig., Porches & Decks; Soils -Steel-/ P Fig. Depth to alls, Main; Steel-Blockouts-Wrapped temwalls, Garage; Stee l-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. P!.qpums & Ducts; Clearance -Material -Support -Ins. CSV '1 15. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies Access & Ventilation 16. Insulation Date ^3 OD Card B-1 AV Date Card B-1 Date Card B-1 Date Card B-1 Date P BING (Permit) OK except #'s r Htr. A ss -Comb stion Air Baffle ip a Anc r -Nail PTotection W.V. 1ttin . & Anc or -Nail ection wl'c'V Shower Pan; Test, First Floor -Tub Access est Tub & Shower, oor- ub Access 22. Gas Pipe; Sixe & Anchors Date Card B-1,,ZX Date Card B-1 Date Card B-1 Date Card B-1 Date EL TRICAL (Permit) OK except #'s Fixture & Transformer Clearance -Ins. Protection ec. Receptacles Spacing -Lights & Switches at Doors Boxes & No. of Conductors Stapled 2 mex Installed Close to Edge of Studs & C.J. LXI-quip. Ground made up w/Mach Fasteners -Bond Gas & Water Appliance Circuits in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or AI 30. Range Circle/ / ga Cu or AI -Oven Circ. / / ga Cu or Al Insulated Neutral Q Yes ❑ No 31. - iser Conductors & Ground Main Disconnect 32. E ip. Clearances Panels -Motors -Mach. Equip. Clothes Closet Light -Shower Light -Spa Light 1 Smoke Detector Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date HANICAL (Permit) OK except #'s CK A.C. Ducts Insulation & Support �3 ent an, Exhaust above insulation C ensate Drain & Overflow, Size & Grade OKFine-Vent Access -Comb. Air -Return Air Vent 115 outlet ttic Access & Plailenn if Furnace in Attic Date �' 4 00 Card B-1 Date Card B-1 Date r Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s 60- s Proper Materials & Anchors 4 s tuds-Nailing Spacing & Braces -Plates -Sound aring Walls over Girders & Floor Nailing Dr Stop in Walls (rat proof) Stops, Furred Ceilings -Stairs -Chaser Tubs Headers & Beams -Size & Bearing jingle & Duplex) Date FRAMING (Continued) AW'Pangers-Posl Caps -Anchors -Connectors inq. Joist-Rttr. Ties-Purlin-Roft Brac.-Truss-Shtina.-Rfna. ( >t 448!Firep1gce Ties or Type A Flue -Fireplace Throat Clearance N8!At' cess; Size & Romex Protection -Draft Stop -tris Baffles �Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions Y.e5l. Gargle Fire Protection Framing &*r.--Prope_qy Line Firewall & Openings xt. Doors -One T -Check Garage 3rd Story, 2 Exits /)£r4' Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection L58—Plywood on Roof Overhand -Attic Vents -Ratter Outriaoers L$?—Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access A59!Glaiing Area -Glass Protection -Skylights -Plastic p5 ear Walls; Nailing -Bolts 60. Brace Interio Exterior II Panels �Da 61. Insulatio Wa - ailing 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date pb Card B-1 Date Card B-1 Date X61 L (Plans).OK except #'s _ABrExt. eps'- oi& Sidelight Protection -Landings m elector Furnace Vents -clearance -Comb, Air -Connector - Floor -Ducts -Mach. Protection Fixtures & Tub cB-8--Efec. Ti m-ICSubpanel, Breaker Sizes & Labels @9i5iairs & Rails go.aoe-or-Stove, j Clearance -Hearth -_ El� ec.Wlets at Wood Panel, Int. & E 92!Kit. Fi Appliance; Ground -Air Gap -Cooking Clearance ec. ets & Receptacles at Kit. Counter arage Fire Door; Swing -Landing -Closure Z -Garage -Damper 1576-Ift. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Aboye Floor -Mach. Protection I ech. Equip. Listed for Location Da-fl—ec. Figgaplacles in Garage (F.F.I.)-Romex Protection 7 sulation-Foam-Looked in Attic uard Rails & Deck Construction -Post Caps n,LBents & Crawl Hole Door Drainage & Wood -Earth 4-T—learance Looked under FI or O Yes 82. Following lnstld./Drive es D No/Walks ] Yes JaIGPlanters 0 Yes D No A.4&56—cco Brown -Finish A.C. Uni4Disconnect, Electrical -Plumbing ants Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86'.', terlNiNhBiszromrect-Electrical, Plumbing 1$Z,flf�erior Elec. Trim, G.F.I. Receptacle -Underground bay iii9ilationThroughoutHouse Protection orrections from Previous Inspections V d9T- as Tg.%1.M6ters Tagged, Gas -Electric ater & Sewer Connected -C/O to Grade -HD Approval 9 nergy Compliance Certificate -Other Certificates r i 94_Jrdress Posted Dated Card B-1 Date Card B-1 Dat 90k0leA2Card B-1 Date Card B-1 Date I I Card B-1 Date Card B-1 Comments at Final: MICHAEL MOONEY 5AMADROivEAVE. CML ENGINEER ORok=E, CA 95966 RCE 20647 (916) 533-2131 Butte County September 11, 2000 Development Services Department Building Division 7 County Center Drive Oroville, CA 95965 RE: Prater Residence #00-112,4 This answers field inspectors concerns stated in Correction Notice dated 9-06-00 by Gary A. The shear walls at the front`.of the garage, 214", while not as stated on the plans are well within the allowable shear force for the shear wall schedule (223 lbs/ft,<295 lbs/ft). The addition of a door in the garage left wall does not change shear value enough to require renailing (65 lbs/ft < 195 lbs/ft). Thank you for your consideration and patience. LOERKE INSULATION CO., INC. INSULATION CERTIFICATE 18 Regal Way Oroville Number and StreetCity • T Coin Subdivision DESCRIPTION OF INSTALLATION Lot Number 1. ROOF Material Brand Name Thickness (inches) Thermal Resistance (R -Value) 2. CEILING Batt or Blanket Type_Eiberglass Batts Brand Name Johns Manville Thickness (inches) 10.25° Thermal Resistance (R -Value) R30 Loose Fill Type - - Fiberglass - - - -----Brand Name Johns Manville- - -- Contractor/s min. installed weight/ft sq. .500 fib. Minimum Thickness 13" inches. Manufacturer's installed weight per square foot to achieve Thermal Resistance (R Value) R30 3. EXTERIOR WALL Material Fiberglass Batts Brand Name Johns Manville Thickness (inches) 35' Thermal Resistance (R -Value) R13 4. RAISED FLOOR Material Fiberglass Batts Brand Name Johns Manville Thickness (inches) 6.5" Thermal Resistance (R -Value) R19 5. SLAB FLOOR / PERIMETER Material Brand Name Thickness Thermal Resistance (R -Value) Perimeter Insulation Depth (inches) 6. FOUNDATION WALL Material Brand Name Thickness (inches) Thermal Resistance (R -Value) DECLARATION I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy EfficiencyStandards for residential buildings (Title 24,Part 6, California Code of Regulations) as indicated on the ertificate of compliance, where applicable. C.L.#499150-�—�i�% Item #sure, ate Item #s Signature, Date Item #s . q• Signature, Date LOERKE INSULATION CO., INC. Installing Subcontractor (Co. Name) r General Contractor (Co. Name) Or Owner Installing Subcontractor (Co. )ame) r General Contractor Co. Mame Or caner Installing Subcontractor (Co. ae) Or General Contractor Co. Name)Or Owner FEF. --09-2000 04:35 PM BUILDEr2.S. SUPPL"C 5340735 P.01 r.. s Certificate of Conformance certificate. 0 5 0 5 9 THIS IS TO CERTIFY that the glued laminateci tlmber probucts Identified with a collective mark of Engineered Wood Systems (EWS) were manufactured in accordance with the applicable standards and associated specilications Indicated below: ANSI Standard AIgo. 1-1992, For Wood Products —Structural Gived Laminated jjnbor NCR -486 Glued Laminated Timber Combinations And "GAP" Computer Program For Determining Design S!resses AITG 117.93 -- Manufacturing— Standard Specifications For Structural Glued Laminated Timber Of Selttwood Species IT IS' HEB0Y CERTIFIED that the APA EWS trademarked structural glued laminated timber mombers were produced in, a manufacturing facility subject to regular audits in accordance with the Engineered Wood Systems (EWS) Quality Assurance Prograr-h. Routine audits Include inspection of the manufacturing process and evaluation of the In -plant QA program with adequato sampiip to verify conformance to industry standards for lumber grade and glueline bared quality. V/9 X 1.2. 0(, ZgFV`q by - Thomas G. Williamson Executive vice President ENG1NELrrEV WOOD SYSrEMS 19 t rota%sd votppration o; APA — TME ENONEE VO NWr7 A9800AMN 7011 South 19th WWI • P•o. Bax 11700.1aCOM WA 994 11-0700 Taloptw a: (2531 5ES-8800 - Fax Nuntpar: (253) 565-7266 F �, T...�;.; .� •./^<��.�•� e��� •-HT1: u.�; t^Y• , COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530i:8'91-2751. - 7 County Center Drive • Oroville, CA • (530) 538-7541 . •_ 'gin: CORRECTION NOTICE, OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice.this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation,::?"r, please contact this offfiicce immediately. - n dr; Date Inspector r�T i REV n-r�.s'af•..,.'•�,3'4`''7*�-„�^',;,r,�«"L._.r,:�+.i'a-iTi�,'�=•4.:7��e'1rr-e:.,.-n��'�4"``"::i�r "3�:=<.^:.-.y=�i�'�ri«i'�al� COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE R — // Z NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. t ,y_ f`6/e/JG L�/•c/�cJ� SICaIn• Ar nr // f�.!/(Cwt_c1 p� i t "I' / _ _ .. , i_ r Date O fz Inspector F'v� REV 10/92 f COUNTY OF BUTTE y BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center, Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE O C3 L y OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you a any questions pertaining to this matter, or need additional explanation, please contact 's office immediately. M�����N If ry 1 COUNTY OF BUTTE ` BUILDING DIVISION DEPARTMENT OF DEVELOPMENT. SERVICES - 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE R Od // z.y PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, i/ r. t- -ti Date _ Gb &A— Inspector- REV 10/92 PERMIT NO: 26-00 Lake Oroville Area Public Utility District 1980 Elgin street OROVILLE, CALIFORNIAA5966 533-2000 DISTRICT APPROVAL AND VERIFICATION OF INSPECTION BUILDING SEWERS This verification form must be submitted to the.Butte County. Department of Public Works Building Department prior to issuance of a building or occupancy permit, whichever is applicable. . Prior to final approval by Butte County of a Building or an Occupancy Permit, a copy of this verification form, signed off by Lake OroVille Area Public Utility District, must be submitted to Butte County. Date: June 13, • 2000, + Applicant: R. D. Prater - Applicant Address: PO Box 336, Palermo, CA 95968 Applicant Phone No.: 534=9230 Property Location (s): 18 Regal Way, Oroville, CA 95966 Lakeridge Sub Lot 101 A. P. No. (s): 069-580-050-0 - Fees due: All fees,paidi Application for service approved: ' LADE OROVILLE AREA PUBLIC UTILITY DISTRICT Inspection(s) made and successful test(s) observed: Location: By: '41., t Date: Lake Oroville Area Public Utility District release t lose permit: Date: �� //dl DDd By: COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-754 / __/1Y7T NO. (Rev.12/96) APPLICATION AND PERMIT / PARCEL 58-NU BER ZONING 1 BUILDING PERMIT OWNER PRATER, RON TELEPHONE 534-9230 SO. FT. OCC. BUILDING VALUATION . OWNERS MAILING ADDRESS 6129 POWER HOUSE HILL RD, 693 U 12,474.00 169 C 2,197.00 CONTRACTOR D R RSNAME D PRATER CONST. CO. _ TEHONE 534 9230 256 0 1,792.00 1876 R CONTRACTORS MAILING ADDRESS P.O. BOX 336 PALERMO CA 95968 248 U 4,464.00 CONSTRUCTION LENDER BUTTE BANK LENDERS a ODMMUNITY Fireplace A 1,500-00 Total Valuation 1 $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 723-50 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 47028 BUILDING ADDRESS Energy Plan Checking Fee $ 23.00 $ PERMIT FEE $ LAT NO. SUBDIVISIONS NAME 10i I PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑- Duplex ❑ Mobilehome ❑ Other X SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 15-00 Each gas water heater or vent 15.00 TYPE OF WORK NewCf Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: SINGLE FAMILY (3 BEDROOMS Gas piping system 1 - 5 outlets 15.00 90 Building sewer 15.00 Mobile Home S G W @20.00 PERMIT FEE S ELECTRICAL PERMIT Filing ee 20.00 Main Service zo.A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license i i full fo c and effect. License Class Lic. No. 4 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO I000A 23.0 46.00 NEW CONST. DWELLING OCCUR OR ADO. ( a ACD. BMS. SO 3.5Q�: 98.60 N"ONEW RESID. MULTI.OUTLET @7,50 POWER APPARATUS a SINGLE OUTLET cIR. Ex. Occup. OUTLET OR FIXTURES 00 BAS @'_50 LNS Ex. Occup. o IXurEltDrS�REEE,6.) FR., 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE S 141 .60 WORKERS' COMPENSATION DECLARATION 1 Jeby affirm under penalty of perjury one of the following declarations: I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My worker ' cc pens n In urance carrier and policy number are: Cai ii . MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation ' PERMIT FEE $ 80.50 Policy Number ✓j?_Q--C?(-), (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify th in erformance of the work for which this permit is issued, I shall not em oy ny arson in any manner so as to become subject to workers' compensati la s of lifornia, and agree that if I should become subject to the work s' c p sa ' In provisions of section 3700 of the Labor Code, I shall forth it m ose provisions. G' X Date '�`' Signatur of A pl ant - ner ❑ Contractor ❑ Agenif An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 occ CONST. TYPE OTAL FEE $ 16 8 HAz IMP XX I FLOOD I CDF PARCEL Pp D SU X This permit is hereby issued under the applicable provisions of the Butte Cou ty Code and/or Resolutions to do work indica d above or which fees have been paid. �� By Date PERMIT EXPIRES ON & 24 O % (D ,) Receipt No. b WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECT R GOLDEN ROD -APPLICANT i COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive Oroville, California 95965 •Telephone (530) Ajn_ ---rF7""' NO (RevY v APPLICATION AND PERMIT Liu L / /i �i- Am@31 OAPARCINM%imm BUILDING PERMIT owrse TaLsra"a BUILDING VALUATION s YALi"O LA jFfTOCC. oD YAtOA AOORlss 0 3;04,- 00 °° ew 9 O Fireplace "!0, ��� �� �� Total Valuation = AR :FMCT OR maw -e1% ucE►aE • Firma Fee Z '3 X00 S 20.00 Permit Fee '7a3,50 It APICWn T OR oancero YAuw ADDAM Plan Checking Fee 0-2 i K+L0•1pApp1°SS Energy Plan Checking Fee i PERMIT FEE : WT760 Ur ste0"tj "AMEL YAP PLUMBING PERMIT FAng Fee—:Moo Each Tr 7.00 USEOFSTRUCTURE SF'4-• Duplex O Mobilehome O Other aP�F' Solar a heat um water heater 23.00 _00 Water piping 15.00 / S— Each as water heater or vent - 15.00 � S� TYPE OF WORK New * Addition ❑ Remodel ❑ UIlirws O hstalation O Other O Describe Work: Gas piping stem 1 - 5 outleti 15.00 Building sewer 15.00 Mobile Home S G W @20.00 1-11-00 PERMIT FEE t „ ELECTRICAL PERMIT Filing Fee 20.00 Main Service ,00 00" LIes 23.00 I (/ / f C/ Main Service 100A To 1000A 48.00 NEW caaT, owBli+o oeeuv. OR ADDNS. a ACC. 3.528 3.528 YUITLovrLu NONR®lo. ' @7.50 P9NOLE OVRET pOw A.P.PAAATW • 0. EX. OCCU OVr ET OR FWURO aw .w Ex. Occup. OVRE r. 610. EA 5.00 _ Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 p 0 PERMIT FEE : MECHANICAL PERMIT Fling Fee 20.00 Heating9 20 Cooling Hood 8.50 $ Ventilation O.SO PERMIT FEE f Mobile Home Installation Fee = Energy Inspection Fee Is ° " `°116T TYPE TOTAL FEE $ Z. 0. fE W► RGOO co P e. (��[ 4,9 4 5-6 D o- 3 6 , (0 C? This permit is hereby issued under the appricabl provisions of the Butte County Code and/or Resolution .! do work indicated above for which fees have been p id. 1l 75,&5) By PERMIT EXPIRES ON Date -14 COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 PERMIT APPLICATION DATA SHEET OWNER: Pk k ASSESSOR PARCEL NUMBER: Q & (? — S 0 Proposed Building Use: Building Inspector: N&G-00 Date: $_ — / 111 — C;1 0 At time of permit application, I wA advised the following data must be submitted prior to permit processing and/or issuance: Date Received By ❑ 1. All items have been submitted -------------------------------------------------------------------------------------- 02. Plot plans, 3/4 sets, signed by the preparer of plans. ---------------------------------------------------- ❑ 3. Complete plans, 3/4 sets, signed by the preparer of plans. --------------------------------------------- 04. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! --------- ❑ 6. Energy Design Compliance and supporting documentation. ------------------------------------------- ❑ 7. Statement of Intent for Non -Heated and A/C Buildings. ------------------------------------------------ El8. Hazardous Material Form. ----------------------------- ------------------------------------- 9. Manufactured Home data and instal ees of $ I_OMUP�41 42 Ir 1W . Impact fees as shown on the alta iKg/California Department of Forestry ❑ 3. OEtation d elevation certificate. -------- rand plot plan approval. ❑ 15. City of Chico plumbing permit. --- schedule. Health Department. Down Specifications. ❑ 16. Plot plan and business license approval frorq the City of Biggs. ---------------------------------------------- ❑ 7. Planning approval for (A) Use: IL. (B) Parking:4 --------- 1 V-ontact Land Development about V Improvements, ❑ Drainage, egal Parcela� --- ---- Encroachment Permit for driveway construction approval nor to occupancy). �----- 1 - � Y ( PP prior P Y)� ----------------- ❑20. Pre -inspection for required Request to Building Inspector on / 1) I5;MA ❑21. Contractor's license information. (Number, Name Style, Classification). ------------------------------------ ❑22. Workers' Compensation carrier and policy number. ----------------------------------------------------------- ❑23. Owner -Builder Verification (Given to owner ❑, Mailed to owner 11) - -------------------------------------- 024� Letter of signature authorization.-------------------------------------------------------------------------------- �} A`V- Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- ❑26. Letter of intent on building use. ------------------------------------------ ----------------------------------------- 027. Manufactured Home utility clearance. --------------------------------------------------------------------------- ❑28. Existing violations and/or expired permits. ---------------------------------------------------------------------- ❑29. 0433 A, ❑Grant Deed, ❑ M.H. Title, ❑ Check to H.C.D $ .--------------- ❑ 3 0. Other:------- (Date) Wh you issue the p t pro ss as follows 11 Mail to owner, ❑Mai to contracto . Telephone YG3 -.J d and hold for pickup a o ce• Deliver with inspector. .lrt2 ue-T dew (,//9/00 S",I �% Applicant: Date: Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, 01Air ollution Date: By: Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Other: Date: By: 1. Index permit application for the above items numbered: 8V Ian Check List 2. Additional items required: Contracto eslgner, weer was advised of the above required data by 13 phone mail, 13BuMing Division counter, by Date: Contractor, _finer, owner, was advised of the above required data by ❑ phone, mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Div'sion counter, by Date: Plans reviewed by: Date: Plans approved by: Date: d —27.- o b Sets of plans on hold int Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division. COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 SCHEDULE OF FEES DUE OWNER�— A.P. # <�&q PROPOSED BUILDING USE DATE -/9- —� RECEIPT # DATE REC 1. BUILDING PERMIT FEES � _ n -- Balance Due ................ $ �� ��/�f(4 � -- Additional Fees Due ........... $ -- Additional Fees Due ........... $ ef - Revised Plan Checking Fee ....... $ 2. SCHOOL DISTRICT FEES Q & J f LL P, (paid at District Office) 3. SHERIFF FEES (paid at Building Division) Residential ........ �_ x $360.00 = $ 3 60, 03 �, Units Commercial (sq.ft.)... x $0.03 = $ Sq. Ft. 4. URBAN AREA FEES (paid at Building Division) Residential (per unit) . x ; _ $ #Units Amt. Commercial (sq.ft.) .. x =$ Sq. Ft. Amt. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES V$89 10.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK Q .00 (paid at Building Division)_ 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER At time of permit applic�tionj j�was dvised the above fees are required to be paid prior to issuance of the building permit. These fees may be chapgedMringAlyrpt4n checking process. APPLICANT DATE 0� Pursuant to Government Code Section 660 , u are hereby notified that items 2,3,4,5,6,8,9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original -Building Div. 2nd Copy - Applicant 3rd Copy - Owner (Rev. 2/97) COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 SCHEDULE OF FEES DUE 1�— OWNER PROPOSED BUILDING USE 1. BUILDING PERMIT FEESoe 1.4 04 --Balance Due ................ $ -- Additional Fees Due ........... $ -- Additional Fees Due ........... $ Revised Plan Checking Fee ....... $ 2. SCHOOL DISTRICT FEES Q n J (LL f, (paid at District -Office)---- j 3. SHERIFF FEES (paid at Building Division) '-:: -! Residential ........ x $360.00 = $ 3 ,',tom Units /t"J Commercial (sq.ft.)... x $0.03 = $ Sq. Ft. 4. URBAN AREA FEES (paid at Build ng Division) Residential (per unit) . i.� _ $ J #Units' Amt. [, Commercial (sq.ft.) .. x =$ �j Sq.Ft. Amt. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES 10.00 (paid at Building Division) 7 SRA FRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) w 10. OTHER A.P. #Q&9 DATE' C� RECEIPT # DATE REC r At time of pet`nut aDplicatxott was ,dv�i�ed the above fees are required to be paid prior to issuance of the building permit. These fees may be changed rin checking process. APPLICANT 1 DAT Pursuant to Gave.rnmayt C-ode,Section 660 , you are hereby notified that items 2,3,4,5,6, 8,9, a d 10 above may have been iVm&p ed on yours project. You�have-90 ays-from the date of approval of the project or from the imposition of the above mentioned items duringXWhich you matey?� protest. The requirements for a protest are specified in Government Code Section 66020(a). Original -Building Div. 2nd Copy - Applicant 3rd Copy - Owner 6. Rev? 2/9_7b 4y BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Building) School District Building Department No A.P. Number I(% 5A-) —05-0 _ Jurisdiction: -city I x ]County Property Ownerr ROAI /41 T Property Location/Address wA Y Subdivision Lot No. C.r 1-&-;, • Residential Development E-77 ........................................................................... : ... ................................... Sq. Footage No of Living Mobile Home Addition/ *Supplemental to (Group R) Units Installation Conversion Permit # *(No foundation inspection): ............... & us ia -7 mmercial/Ind tri'ly --' _;f ' - - q.. ta66, New Addition (including Exterior Roofed Areas) Building Department Representative Date iriour moans revievveu uy acnooi uistrict r-ersonnei-i District Identification No.. School District certifies that /0 (Applicant) (Street Address) (City) has complied with the requirements of Resolution No. representing square feet. School District Representative Paid by Check # Remarks: N (Phone Number) M/ (State) (Zip Code) —0 by payment of $ rm) I AB 2926 S t FULL MITIGATION S. v Date I Notice: You may protest the imposition of the fees identified above by, su6mitting'a written protest to'the District, in compliance with Government Code Section 66020(a), within. 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees iin any court action'. If, subsequent to the'School District Representative signingthis Butte Cou I nty Schools Impact Fee Certification Form. the School. District is notified by the'applicable Local Planning Agency.that this project is being reviewed under the California Environmental Quality Act ICEQA), this project may be.subject to additional school fees. to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.x1s (10198)dmm f June 6, 2000 Ron Prater P.O. Box 336 Palermo, CA. 95968 Department of Development Services Building Division 7 County Center Drive Oroville, CA 95965 (530) 538-7541 (530) 538-2140 FAX Assessor Parcel Number: 069-580-050 Building Permit Number: 00-1124 This office reviewed building plans for the permit application referenced above. The plan examiner's comments are listed in PART - I below. Please respond in writing to each comment in PART - I by completing and returning the enclosed PLAN REVIEW RESPONSE FORM. Indicate which detail, specification, or calculation shows the requested information. Additional response information is included on the response form. Your complete and clear response will expedite the re -check and approval of this project. PART — I Provide additional information and/or make revisions to plans, specifications and calculations as follows: N"'/The braced wall details, on page 3 of the building plans, are not clear and legible. Plans and specifications must be drawn to scale and shall be of sufficient clarity. Please be sure to include on the resubmittal the engineer's "wet" stamp, signature, registration number and expiration date on all sheets of plans depicting the designed elements and cover sheets of calculations. 5ht--A2 d2. Provide clarification about the type of material being used for braced wall panel's identified as 1 and 2 on the structural calculation's and the building plan's. Pkv i r�t -=- S'W Sc#r=V. O/V Provide clarification about the installation of the LTT 19's located in the master bedroom. Pe- .4?,tS .Since this room is located on the second floor level, how will this be accomplished? OtScu-rf cm russ D 1 has a reaction of 9277 at 92 without any foundation or pier support. Provide clarification about the drag truss requirement at truss Bl. 1>14- Y Rndicate the size of the typical header, porch header and garage door header's. eview of the building plans by the Butte County Building Division engineer has not been completed at this time. Any additional comments from the engineer will be addresses in separate correspondence. Plan review will continue upon receipt of the above items. Additional comments may be generated from your response above where plan documents were incomplete, inconsistent, or not adequate to depict code compliance. 1 of 2 PART - H The items identified below must be submitted prior to permit issuance. These items were noted at time of permit application on the PERMIT APPLICATION DATA SHEET. 1 Pay Balance of Building Permit fees in. the amount of $1,139.28. Pay impact fees: 2.1. Complete and return the Butte County School Impact fee certification form. 2.2. Sheriff fees = $360.00. Sanitation and plot plan approval is required from the Butte County Environmental Health Department. Vtbain Encroachment Permit for Driveway from Butte County Public Works Department. ubmit a Recorded copy of your Agricultural Acknowledgement Statement. If you wish to discuss any requirements in PART - I, you may contact me at (530) 538-7541 between the hours of 1:00 p.m. and 4:00 p.m., Monday through Friday. The attached checklist must accompany corrected items. Sincerely, Glenn Gibbons Plans Examiner C.C. Michael Mooney 2 of 2 PLANREVIEW RESPONSE FORM In order to expcdite the review of your plans, please complete the following information and return this form Kith your re -submittal. this form is not complete, as to all correction items, we will not be able to accept yodr re -submittal for review. "Dere must br a va: response to every- item requested in our plan correction letter. "By others" is not considered a valid response. Please indicate yo.. response to each item and the location where the informatior can be found on the ptan_c'calcs. ATTACH THIS FORM TO A COPY OF YOUR PLAN REV EW LETTER AND RETURN WITH Rl<VISED AND ORIGIN OWNERS NAME DATE: X2 - ASSESSORS PARCEL NUMBER. PERMIT NUM ER L - IIZy RESPONSE FOR PLAN ,CHECK/LETTER DRATTED: - (a Lcoj+rJC>Uk 1,5" PLAN CHEC rT)~M # RESPONSE BY: LOCATION ON. PLANS/CALCS: uta o 72�_> (COMMENTS: o �.._ - ,� NA �J _I rl LLQ 1/t5Lt-5 1 �l J C NL_I"NE_t,-ILE C) 1 "Uo N PLAN CHECK ITEM # RESPONSE BY: LOCATICN ON PLANS/CALCS: M. 5 COMMENTS: CSS `CD U<Ti LL'I-E- S`, -a- hPS . PLAN CHECK ITEM # RESPONSE BY: IM � UVl cSL` LOCATION ON PLANSICALCS: Lt � COMMENTS: YVl ✓lel N� - ��\a 1'�% t`�1JdK�iJ �'r� C, 3 �bL�`iIIS{� xy)V0rQo - iomn 1+ PLAN CHECK rrEM # RESPONSE BY. LOCATION ON PLANS/CALCS: . COMMENTS: TD) h I -i In FP) hA I \IBJ 9t*'W_ - RESPO.NSE FOR F.AN CHECK, LETTER DATED PLAN CHECK ITEM 0 RESPONSE BY: LOCATION ON PLANS,CALCS: CONIN12NTS: PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANS/CALCS: COMMENTS: _�(feVL= Uj)ft C _ PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANS/CALCS: COMMENTS: C!, t, s b _.1. W f A WA PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANSICALCS: COMMENTS: PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANS/CALCS: COMMENTS: PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANS/CALCS: COMMENTS: PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANS/CALCS: COMMENTS. 0 PERMIT NO: 26-00 Lake Oroville Area Public Utility District 1960 Erin street OROVILLE, CALIFORNIA 95966 533-2000 DISTRICT APPROVAL AND VERIFICATION OF INSPECTION BUILDING SEWERS This verification form must be submitted to the Butte County Department of Public Works Building Department prior to issuance of a building or occupancy permit, whichever is applicable. Prior to final approval by Butte County of a Building or an Occupancy Permit, a copy of this verification form, signed off by Lake Oroville Area Public Utility District, must be submitted to Butte County. Date: June 13, 2000 Applicant: Applicant Address: Applicant Phone No.: R.D. Prater PO Box 336, Palermo, CA 95968 534-9230 Property Location (s): 18 Regal Way, Oroville, CA 95966 Lakeridge Sub Lot 101 A. P. No. (s): 069-580-050-0 Fees due: All gees paid. Application for service approved: &AYet OROVILLE AREA PUBLIC UTILITY DISTRICT Inspection(s) made and successful test(s) observed: Location: Date: M Lake, Oroville Area Public Utility District release to close permit: Date: By: Cq' AND WHEN RECORDED MAIL TO: M BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CA 95%5 2000-00 1 866 1 Recorded Official Records County Of BUTTE CANDACE J. GRUBBS Recorder ROSEMARY DICKSON Assistant 10:00AM 22 -May -2000 REC FEE 7.00 COPIES 1.00 Cindy Page 1 of 1 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: 4 W"V4� OT -bJ C, t44 e -Boal- 65 6T W40, 0 -N e,5 0/'1Z/ «/ 1q, 4mo ts— iP# 6/0q - 560 - Cann- Date imDate .5�2O0 i on 4,441 aer4,4 Ai Mop C,,41ed Zgkerl4e, r 2oa-ped lvi-eke office c4'4 -P- 2eNe.De,r o� o-� C►����'c�r �A� on C)(4c)b-ey' 2S, 2�� I, i ►� State of California County of SOAe, :22N, 1&./CJ J/e6'J,J IIIZAfE.� personally appeared12 t�,,.�\,� 'ems �qr, Personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal, Signature` P -a% Seal: KEVIN FEUERWIN a A.P. # Comrnls w U11 00335 Fhtr CPS1 Ftcay Pub9a r. '•' Butte County. CaStotnm "n Aly CommWlon Exp. J M. 27. 2002 1 APAtOVED ❑ CONDITIONALLY APPROVED " . ❑ RESOLVE PROBLEMS PRIOR TO APPROVAL PERMIT CLEARANCE Permit #: �lJ _ 2�1 Date: 60 Genera/Information � 11 AP# �b�i-ScgD-.OSQ Owners Name: i��J� 2 ti`s' Parcel Acreage: 12 Owners Address: Ems! V Q� ACU,_% E W U_ 2_L-)_ Building Site Address: PrODeftY Information Permit Type: ❑ Agriculture Building ❑ Commercial ' ❑ Industrial ❑ Mobile Home 91 SFD ❑ Residential Accessory ❑ 2nd Dwelling ❑ Multi -Family >2 units per parcel ❑ Septic ❑ Well ❑ Other Zone District: A R — 1 Date of Zoning Ordinance: 2 — Z8 — 8 H General Plan: 1`211 Development Agreement: Use Permit: Variance: Parcel Is In: Land Conservation Agreement -ffNo ❑ Yes, check use Minimum Acreage: Nitrate Action Plan IN No ❑ Yes Violation Area 'NNo ❑ Yes Specific Plan Mf No ❑ Yes ❑ Chico ❑ D2N ❑ Cohasset Enterprise Zone M No ❑ Yes, check use Floodplain @j No ❑ Yes Zone: I_ Panel Number: U JM ❑ Watershed Protection Zone No Yes Proposed Use Complies With: M General Plan ® Zoning Proposed Use Requires: ❑ Use Permit ❑ Minor Use Permit ❑ Administrative Permit ❑ Accessory Building Use Commercial/Industrial/Multi-Family Uses: Parking: ❑ Parking Requirements are OK as Shown Landscaping: ❑ Landscaping Requirements are OK as Shown Road and Drainage Improvements Required: ❑ No ❑ Yes Aoolicable Setbacks: ❑ Other Other Zoning Code Street & Highways Fire Prevention Subdivision Ma Front Side © 3 Side street Rear O 3 O Heiaht Peri»%t Clearance Environmental Health issues - Septic Permit Review: Agriculture Affidavit Required ❑ No ❑ Yes Well Permit Review: Designated Well Site ❑ No ❑ Yes Land Development Review: Drainage Plan (Com/W/Multi) • ❑ No ❑ Yes parcel Created by, ❑ Deeds Date of Creation: Legal Access Provided: ❑ No ❑ Yes Deed Reference: Legal Access Required: ❑ No ❑ Yes Parcel Frontage on Publicly Maintained Road: ❑ No ❑ Yes, Road Name: Complies with County Standards for Deed Creation: ❑ No ❑ Yes Comments: JgMap Date of Recording: `- t Lot: ) Block: Book:_V Pagel I ' -onditions That Must be Met Prior to issuance of Permit: ❑ Verify Legal Parcel ❑ Verify Legal Access ❑ Comply with condition no. of conditions of approval for the ❑ Provide Creation Deed ❑ Obtain a Certificate of Compliance (See Planning Division for application). ❑ Construction across property lines is not permitted (See Land Development for a Merger Application/Lot Line Adjustment). ❑ Comply with Old Subdivision Lot Ordinance (Maps Recorded Prior to Book 17 of Maps Page 23). ❑ Construct road to ❑ Meet parcel size required by zone ❑ Meet current EHO requirements. ❑ Other :ereral Comments: "MICHAEL MOONEY CIVIL ENGINEER RCE 20647 Butte County Building Inspection Department 7 County Center Drive Oroville, CA 95965 Re: Ron Prater Construction 5A MADRONE AVE OROVILLE, CA 95966 530-533-1216 May 25, 2000 This is to confirm that I have reviewed the trusses for the proposed residence and that they are adequate for my design. Thank you for your consideration. Yours, Michael Mooney My license expires 9-3-01 L� RESIDENTIAL PLAN REVIEW GUIDE SINGLE FAMILY, DUPLEX AND MISCELLANEOUS ONLY Owner: OJ - E fZ Building Permit Number: d - �� y Plans Examiner: A. P. Number:—(961 —580- Q -50 NERAL: ' Zoning requirements — (number of permitted living units). Building permit valuation. Plans signed by the designer. Proper description of work on the application. Existing violations on the property. f Recorded notice of violation.- PLOT iolation.PLOT PLAN: .0 Complete parcel size and dimensions. Z. Setbacks, side yard, easements, etc. Other buildings or structures. Grading, fills and/or drainage. ,K Flood hazard. Special conditions on Parcel Map (Noise, SRA, Fire Sprinklers, Water Tender, Traffic and Drainage fees). /f. FAU & FAS road setback. J( Building or utilities across lot lines (record form). )FLOOR PLAN: 1 ,Plans and specifications drawn to scale with dimensions and of ari (Uniform Building Code section 106.3.3). % �rqt �-5 a/J -3 Z. 10% of natural light and 5% of ventilation (Uniform Building Code section 1203). Egress windows (Uniform Building Code section 310.4). .4' Skylights (Uniform Building Code section 2409 & 2603.7). Glazing in Hazardous locations (Uniform Building Code section 2406). Required room sizes and ceiling heights (Uniform Building Code section 310.6). J% GFCI in baths, garage, kitchen, wet bar, and exterior receptacles (NEC 210). X. Prohibited locations of gas water heaters (Uniform Plumbing Code 509& 1213.5). Prohibited locations of gas heating equipment (Uniform Mechanical Code 304.5). Garage firewall separation - required on garage side including supporting walls and posts (Uniform Building Code section 302.4 exception #3). Wood stove location - Alcove clearance (UMC section 205 confined space & 223 unconfined space). Smoke detectors (Uniform Building Code section 310.9.1). IX Water closet clearances (Uniform Plumbing Code 408.5). W. Shower compartment minimum 1024 sq. in. & 30" circle (Uniform Plumbing Code 412.7). Page 1 of 2 STRUCTURAL DETAILS: Cly Conventional construction — Unusually shaped buildings (Uniform Building Code section 2320.5.4). Standard bracing or engineered design (Uniform Building Code sedtion 2320.11.3). f3 Clerestory requiring balloon framing and/or engineering. ;47 Three story building requiring engineered calculations and plans. Foundation plan complete enough to construct building. Floor construction details complete enough to construct building. Elevations and wall construction details complete enough to construct building. Roof construction details complete enough to construct building. Rafter ties or bearing ridge beam. Fireplace construction details and calculations if necessary. 1 Garage door header size(s). 2 Porch header size(s). Stud heights. A/4. Expansive soil — special foundation design required. W."Retaining walls requiring design. 67 Special Inspection requirements. Header sizes. Gypsum wallboard nailing inspection required. MISCELLANEOUS ITEMS: .dY Stairway details — landings, rise and run, head clearance, handrails (Uniform Building Code section 1006). Guardrails (Uniform Building Code section 509). Brick or stone veneer (Uniform Building Code section 1403). Exterior plaster — weep screeds (Uniform Building Code section 2506.5). 4 Roof pitch for roof covering (Uniform Building Code Table 15-B-1& 2, 15-D-1 & 2). Roof covering type — (fire hazard). Foam insulation — protection. .8' 36" halls and stairways (Uniform Building Code section 1004.3.3.2). 9� Two exits on three — story dwellings (Uniform Building Code section 1004.2.3.2). k0. Underfloor access and ventilation (Uniform Building Code section 2306.3 & 2306.7). W. Attic access and ventilation (Uniform Building Code section 1505). Al. Combustion air for fuel burning appliances — LPG requirements. 4 ound requirements. X. Energy design compliance and supporting documentation. 1 Flashing at all exterior openings. l CDF responsible area requirements. ,iBuilding Permit requirements: SRA. 1 Flood elevation certificate. Fire Sprinklers required. 1 , Special Inspection requirements. Use Permit conditions. 1 -?"6. Sub -Standard Housing letter. . Page 2 of 2 0 0