Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
072-080-034
'e. a f 72-08-34 1373-91B`,P,E ' VARASTEN.,,, Ben 45` Sk'-nner;yLri;' Oroville xY (new garage) 02'080-034 i� PERMIT#,94 2488" --. VARASTEN, BEN / 45 SKINNER LN ; ° OROV,ILLE �/® J CONVERT GARAGE T0, " SF.,- 07�-OY-4��o� .I 1 i I i y f nn f V ,•�I • �� ��kbu { 1: Jd. I F I RESIDENTIAL 072-080-034PE- -- _ -. _ -- -- ---- - RMIT#94-2488 VARASTElj, BEN 45 SKINNER LN.., OROVILLE CONVERT GARAGE TO SF 0�1p ®t4 0I% JOB FINALED (Date) 16>1,31 Signature V=OK O = Not OK Not = Not Readyable MOBILE HOMES Date/Initials MOBILE HOME UTILITIES (Plans) OK except #'a 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O Concrete 4. Water; Location -Teat -Easement Needed (Sketch) 5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete 6. Gas; Location -Teat -Wrap: / /"L"ft. / /"Nat. or/ P'L"ft./ /"LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date/Initials MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3.. Gas; MH Teat -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy MISCELLANEOUS Date/Initial DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs:Connectors Shthg: Rfg: Bracing 5. Alum. Awn.; Columns-Connections-Spllce-Decal-Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date/Initials POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.;Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test V=OK 0 = Not OK = Not Applicable RESIDENTIAL E = Not Ready Date/Initials UNDERFLOOR (Plans) OK except #'s 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Main; Soils-Elec. Grnd.-/ P' Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth S. Stemwalls, Main; Steel -Bloc kouts-Wra pped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fell -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date/Initials PLUMBING (Permit) OK except #'s 16. Water Htr.; Vent -Access -Combustion Air -Baffle 17. Water Pipe; Test & Anchor -Nail Protection 18. D.W.V.; Test -Fittings & Anchor -Nasi Protection 19. Shower Pan; Test, First Floor -Tub Access 20. Test Tub & Shower, Second Floor -Tub Access 21. Gas Pipe; Size & Anchors Date/initials ELECTRICAL (Permit) OK except #'s 22. Fixture & Transformer Clearance -Ins. Protection 23. Elec. Receptacles Spacing -Lights & Switches at Doors 24. Size Boxes & No. of Conductors -Stapled 25. Romex Installed Close to Edge of Studs & C.J. 26. Equip. Ground made up w/Meth. Fastners-Bond Gas & Water 27. 2 Appliance Circuts in Kitchen & Conductor Size/GFI 28. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al. Insulated Neutral ❑ Yes ❑ No 30. Service -Riser Conductors & Ground -Main Disconnect 31. Equip. Clearances Panels -Motors -Mach. Equip. 32. Clothes Closet Light -Shower Light -Spa Light 33. Smoke Detector Date/Initials MECHANICAL (Permit) OK except #'s 34. A.C. Ducts Insulation & Support 35. Vent Fan; Exhaust above insulation 36. Condensate Drain & Overflow; Size & Grade 37. Furnance-Vent; Access -Comb. Air -Return Air Vent -115 outlet 38. Attic Access & Platform if Furnance in Attic Date/Initials FRAMING (Plans) OK except #'s 39. Sils, Proper Material & Anchors 40. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound 41. Bearing Walls over Girders & Floor Nailing 42. Draft Stop in Wells (ret proof) 43. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 44. Headers & Beam -Size & Bearing Single & Duplex) Date/Initials FRAMING (Continued) 45. Hangers -Post Caps -Anchors -Connectors 46. Cing. Joist-Rftr. ties-Purlin-roof Brec-Truss-Shthng.-Rfng. 47. Fireplace Ties or Type A Flue -Fireplace Throat clearance 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 50. Garage Fire Protection Framing 51. Property Line Firewall & Openings 52. Ext. Doors -One 3' -Check Garage -3rd Story, 2 Exits 53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers 55. Siding -Nailing Veneer 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 57. Glazing Area -Glass Protection -Skylights -Plastic 58. Shear Walls; Nailing -Bolts 59. Insulation -Wells -Ceilings 60. Infiltration -Walls -Windows Date/Initials FINAL (Plans) OK except #'a 61. Ext. Steps -Door & Sidelight Protection -Landings 62. Smoke Detector 63. Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor -Ducts -Mach. Protection 64. Bedroom Exiting 65. G.F.I. & Bath Fixtures & Tub Access -Spa 66. Elec. Trim & Subpanel; Breaker Sizes & Labels 67. Stairs & Rails 68. Fireplace or Stove; Clearances -Hearth 69. Elec. Outlets at Wood Panel; Int. & Ext. 70. Kit.Fixt. & Appliance; Grnd: Air Gap -Cooking Clearance 71. Elec. Outlets & Receptacles at Kit. Counter 72. Garage Fire Door, Swing -Lending -Closer 73. A.C. Duct in Garage -Damper 74. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage; Above Floor -Mach. Protection 75. Plb., Elec. & Mach. Equip. Listed for Location 76. Elec. Receptacles in Garage; (G.F.I.)-Romex Protection 77. Insulation -Foam -Looked in Attic ❑ Yes 78. Guard Rails & Deck Construction -Post Caps 79. Fdn. Vents & Crawl Hole Door-Drainagge & Wood -Earth Clearance Looked under Floor O Yes 80. Following instld.; Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑ Yes ❑ No 81. Stucco; Brown -Finish 82. A.C. Unit; Disconnect, Electrical, Plumbing 83. Vents Above Roof; Plbg: Appliance -Fireplace: Clearance to Openings 84. Water Well; Disconnect, Electrical, Plumbing 85. Exterior Elec. Trim; G.F.I. Receptacle -Underground 86. Ventilation Throughout House 87. Glass Protection 88. Corrections from Previous Inspections 89. Gas Test -Meters Tagged; Gas -Electric 90. Water & Sewer Connected -C/O to Grade -HD Approval 91. Energy Compliance Certificate -Other Certificates Comments at Final: COUNTY OF BUTTE - DEPARTMENT OF DEVEL�'dPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, Cariforpia §5965 - Telephone (916) 538-754 PE I 0. APPLICATI®N AND PERMIT ��^ �4 9 ASSESSOR PARCEL NUMBER BEN VARASTEN ZONING ARM BUILDING PERMIT OWNER n79_o8n_i4mf (08) TELEPHONE 274-0718 SO, FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS P0 BOX 51656 SAN JOSE, CA 95151 539 @ 20 10 780.00 CONTRACTOR'S NAME nWNER TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation Is LENDER'S MAILING ADDRESS Filing Fee $ 20,00 Permit Fee $ 126.00 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ n Penalty $ BUILDING ADDRESS 45 SKINNER LANE PERMIT FEE $ PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.00 Solar or heat pump water heater 23.00 LOT NO. SUBDIVISION'S NAME PARCEL MAP Water piping 15.00 Each gas water heater or vent 15.00 USE OF STRUCTURE SF ❑Y Duplex ❑ Mobilehome O Other SPECIFY Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G I W @20.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other`XX Describe Work: CONVERT GARAGE TO S/F PERMIT FEE $ 7-1.00 Contractor ELECTRICAL PERMIT Filing Fee 20.00 Main Service'OR LESS ( 200A OR LESS I 23.00 Main Service ( 200A TO 1000A I 46.00NEW LLINOCCUP. OR ADDNS.T ( DWBEACCGBLDS. I so p 3.5C FT, 1 . 85 NEW CONST. MULTI -OUTLET •NON.RESID. ( BRANCH CIRCUITS I @7.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one) ❑ I am a licensed under provisions of Chapter 9, Division 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification WI, as the owner, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec 7044) ❑ I, as the owner, am exclusively contracting with licensed contractors. (Sec 7044) El am exempt under Sec. Business and Professions Code forthis reason ( POWER APPARATUS I & SINGLE OUTLET CIR. Ex. Occup. ( OUTLET OR FIXTURES ) 20 @ 1.01 BAL. .50 FIXED APPLNS.OR EX. DCCUp. (OUTLETS IRESID.1 EA. I 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 WORKER'S COMPENSATION INSURANCE 1 declare under penalty of perjury (check one): ❑ This permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Dept. of Development Services, Building Division a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -insure. x�l I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. Notice to Applicant: If after making this statement, should you become subject to the Worker's Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit will be revoked. PERMIT FEE $ 38.85 Contractor MECHANICAL PERMIT Filing Fee 20.00 Heating WALL HTR 15.00 Cooling Hood 6.50 Ventilation PERMIT FEE $ 35.00 Contractor I certify that 1 have read this application and state that the above information is correct. 1 agree to comply to all Butte County Ordinances and California State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in c nsequ}enncee of the granting of this permit. q X O xxl Date � 1 Signature of Applicant - Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 5"0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 ocC CONST. TYPE TOTAL FEE $ HAZ. I D. FEES IMP - I FLOOD I CDF I PARCEL I PO H Issu This permit is hereby issued under the applicable of the Butte County Code and/or Resolutions indicated above for which fees have been --"W- By ���` PERMIT EXPIRES ON A f ate! provisions to do work paid. ate N J Receipt No. 167560 WHITE-O.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE BUILDING DIVISION EPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, _ChicorCA - (916) 891-2751 7 County Center_.Drive„Oroville, CA - (916) 538-7541 e't 747 Elliott Road, Paradise, CA (916) 872-6307 If CORRECTION NOTICE NER PERMIT NO. ' A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If y3u have any questions pertaining to this matter, or need additional explanation, please contact this office immediately n Sa i e;e el, C � 'F %/'tom CEJ ✓-e t/ r��'-r i G� Y� / r 1 +� t� r/7 11 o- J L. n it, C 2' V L'C-- rclm ( ti a n "use✓ U, u ra jV 0 01 11 •Z.t �► 'a l�t� ��t ifh C?.r1 'ol v / liq WL YOU !n /-c> Ywu ccs JAr� .; Date Inspector ,a 14 REV 10/92 COUNTY OF BUTTE ' BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico; CA - (916) 8.91-2751 f 7 County Center Drive, Croville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 ° CORRECTION NOTICE OWNER PERMIT NO. •"i A routine inspection indicates that the following violations of Butte County Ordinances exist at the above a ess and should be corrected. Please notify this office when correction of work is comple d. If you have any questions pertaining to this matter, or need additional explanation, please o tact t_'s office immediately. i 61 4m- f' Gc /Cs"' O / l _ N /t I/ l/1 Cwt.( of _ 11/ r1 I, - LA -S2 Date Z7 Inspector .,e /z ------- REV 10/9 .1 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road,. Chico, CA - (916) ,891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916),872-:6307 'S J CORRECTION NOTICE C/89 _z OWNER PERMIT NO. .• $• A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is complet . If you have any questions pertaining to this matter, or need additional explanation, please ptact this office immediately, . 'A Date 472l /40 --/Inspector REV io Insulation Certificate BUILDING OWNER: BUILDING IACATION:S S n Description of Installation ROOF BUILDING MWT Material Brand Name Thickness (inches) Thermal Resistance (R -Value) CEILING Batt or Blanket Type ,L i e ," q16 A5 Brand Name -Uzjem9 Thickness (inches) 42 VThermal Resistance (R -Value) Loose Fall Type Brand Name Contractor's minimum installed weighdh lb Minimum thickness inches Manufacturer's installed weight per square foot to acheive Thermal Resistance (R -Value) EXTERIOR WALL Material ZP�-� /C ,� 5' . Brand Name c,�P,r�c 4 — ityt t ,•�4 Thickness (inches) �/� '% Thermal Resistance (R -Value) RAISED FLOOR Material Brand Name Thickness (inches) Thermal Resistance (R -Value) SLAB FLOOR Material Brand Name Thickness (inches) Thermal Resistance (R -Value) Width (inches) FOUNDATION WALL Material Thickness (inches) Declaration Brand Name Thermal Resistance (R -Value) I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Building Energy Efficiency Standards for new residential buildings contained in Title 24 of the California Administrative Code. �{e ral Contras or Builder) License Number Signature and Title Date Sub -Contractor (Insulation Installer) Lit Prise Number . Signature and Title Date THIS CERTIFICATE MUST.BE PROVIDED TO THE BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION APPROVAL AND A COPY SHALL BE POSTED WITHIN THE BUILDING. JANUARY 1993 ,..•. T..r .,..'W I`t'ry-t ... -y..:.. •. r:.W. , �..,i,{r'-•y"..^q.-,r�nr...,-N•,tl-ij:,,�,r,'.•krra. ^.�•r.y,•.+'%v+i'Y^"r++.1 -1,v,. Tr..�•t>yy,(•�a: r'r^. '�"•f'r�rr��-�an'rnN a'•r`.t,r',.^" ",.. COUNTYOF BUTTE - DEPARTMENT 04EVI�P�,IIIENT,SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 9,5965 -,TELEPHONE (916) 538-7541 PERMITAPP C=AT.ION DATA SHEET X OWNER7 o. Proposed Building Use �/U`�' Building Inspector Date At time cf permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: NNSUo DATE RECEIVED BY 1, Alb items have been submitted: .. `................................... . 2. Plot plans, 3/4 sets, signed by preparer of plans . .......................... 3. Complete plans, 3/4 sets, signed by preparer of plans . ...................... 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............. Hazardous Material Form . ................................ * * . ' ..... 44409-4—Energy Design Compliance and supporting documentation . ............ ... (. 7. Statement of Intent for Non -Heated and A/C Buildings . ..................... . 8. Engineered truss details and layout in duplicate (required prior to plan check). ... . 9. Mobilehome data and manufacturer's installation instructions, 2 sets. ........ { Fees of $ le � ..-QAC ::. �'�i 1P `0 4101. Impact fees as shown on attached schedule. cb* T .... . 12. California Department of Forestry plan approval/fees. ....................... . lood elevation letter (100 year floodby California Engineer .................. roval ME . 14. Sanitation and plot plan appZt Health Department . ........... . 15. City of Chico plumbing permit . ........................................ . 16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: . ........ 18. Contact Land Development about (A) Improvements (B) Drainage. .......... . 19. Driveway permit (construction approval required prior to occupancy). .... ... . Pre Inspection requ�— 20. Pre -inspection for required. .°. to Building Inspector (Date) 21. Contractor's license information. (No., Name Style, Classification) . .............. 22. Certificate of Workmans Compensation Insurance . .......................... Owner -Builder Verification (Given to owner , Mail to owner ............. Recorded copy of Agricultural Acknowledgement Statement . ................... 25. Letter of signature authorization . ....................................... . 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . 27. Letter of intent on building use. .. r`S.................................... . 28. Mobilehome utility clearance. ..... .................................... . 29. Documentation of legal access . ..................... :.................. - - 30. Documentation of 50% subdivision developed or (A) Road improvements completed - t and (B) Parcel meets zoning area and frontage requirements . .............. 31. Existing violations/expired permits . ...................................... 32. Plan check list. ' 33. 34. When you issue the permit, process as follows: Mail to owner. Mail to contractor. ` Telephone and hold for pickup at L#j h 0 office. Deliver with inspector. Other -F _0 -7 Parcel Creation Acreage Applicant Date Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: r Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Contractor, designer, owner, was advised of above required data by — phone _ mail ounter by _ Date Plans checked by Date Plans approved by Date` Sets of plans on hold in File cabinet AP folder Copy - Department of Public Works TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance , �, . .. I - V - E.H. USE ONLY. Plot Pl= Aftachad Floor Plan Anachad h Sent to B.D. .1 lll/ .4, Owner Location AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance fk _-,-Ie'draEome. Other 4,7) Hold final for: Final clearance 0. K. for: NOTE: PL I 6(�- Environmental . Health Specialist 2/01) N M, BUTTE COUNTY SC( OOHS IMPACT FEE CE RTIFICATION FORM One orm Per Building) School D strict Q �G — Q artmen o.�a- p P. Number U41 Jurisdiction ❑ City ® County Property Owner x 4E A/ AZA S 7 /Y - Property _ocation/Address �� S� N /� L ten— ey`?o Subdivison Lot No. Residential Development❑ ❑ Sq. Footage No. of Living M H I Addition (Group R) Units cfa/jL1(% /�"j"" V06t; Commercial/Industrial ❑ 0 Sq. Footage District Identification No. ,��, School District certifies that ,ass (Street Addrdss) (City) (State) (Applicant) (Phone Number) `S-9 6 (Zip Code) has complied with the requirements of Resolution No, U by payment of $ 9� 7iU , represerting square feet. ❑ School District Rep K E f Check here if fee received represents "Full Mitigation".` F Date Paid by Check. # Remarks: Bank Number Paid by :.ash { j If, subsequent to the School District Representative signing this Butte County Schools Impact Fee i Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under. the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. Z 1 White (applicant), Yellow (building department), Pink (school district) f. e�form.+kt (4/94) F , COUNTY OF BUTTE Department of Development Services Building Division Oroville: 7 County Center Dr., Oroville CA 95965 Ph: 916-538-7541 Chico: 1469 Humboldt Rd., Chico CA 95928 Ph: 916-891-2751 OWNER -BUILDER VERIFICATION Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement (yes or no) _YZ,,;. 2. I (have/have not) kc.\je, signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction: Name . Address City Phone Contractor's License No. 4. I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work: Nave Ade ress City Phone Contractor's License No. e 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: Name Address Phone Type of Work Signed: Property Owner S l��ber Date NOTE: This Owner -Builder Verification is sent to you as required by Sections 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. I. 1. csoc9 ELECTRICAL, MECHA�JIC COISTRUCTIOfd �, AND PLUMBING $HAi.L CO;,oLY �, i`OT PLAN CHECKED ) $H NEC WITH H CURRENT EDIT UMC AND UPC. NOTE..—All Materials a Workmanship Shall Be in Accordance With Reco , . of a quaff 9nfzed Good Practices and Uniform Bu Prescribed f r the SPec►tied use in the the National Electrical Code Mechanical CodesaW 00 C1 o LAI�� 03 �o CCj Q 4 R� y k 3 6, —off •/`j• r APPROVED - - Butte Coullty Environmental Heaft� Date— .. = ter. ��! ' �✓+` ,"1 ! -_ { t�J•J 2 1 1 #I q/ sus 16 a C 2"X�" CE1'�iNG -�-s.... 2 y„a,c, F T -C- 2 x C I I/ 2��x �I M/ 61:>svi Ef�\NCT Ulf TH ►6 PCS uND 77e P11 Pce � CC)M�. k'' StICET POCis 67 MIN E�1' Tp ccJ�a� C Z EA/<"A/VC CS -=NSCj11171C.W , AEN/NG r .C, plTcIl 1 ��twideapprove WALL �' CEILING '(.nVEeING Nod = CEiZIA16- tpee V(:54'7 fI %Tl C VENT 2 -6 MFTEe TiEs zxs BUTTE Uuury , BUILDING DEPARTMENT APPROVED AT- Z y” l0 , C , dtl tt0 ec�CCe6s eud ventilation far-C?i. 3?., IIIIC. ,Q- Iq CEIIINo- _T-N S UMT-1 CN WAIL l /NO wer+r qa re YK/L A!/I NN/A'N/rALI Y �L7.[CI/AN O71W //IN✓!a MV[L Y.VMM/.xlp rlM/r/ �'7tJNs!hVI�W�T/MlNI1 '�fN eRI LV rfVl C///.r N0 4 /8 I /7 sT0 R MON I �, — -- — A setback of 5 ft. from the off—' ro�" lines and a setback a :From the road sc.AL (io0' N N ° tri a shall be clear of I K' N09.11'S7E /44.21 Ic 0 i%I e I /8 Nio ci4'E(gl /gs27' N ^. s es or equipment XC@ +' 1 ,e..�Jpa 2-eave overhar f N094dE/0) V73; No /1 Nor �0 NQG'PT't5E /44,9/' � � /VOG •55 (D� /64.51•/ `� �� !/AJfMEN A zea Ta42 /� r0 r Ovi r) //arc//E LEAWIZ, / ! 2 W / / f Roeo oaf 4t/'/OA•a:siir';i).r•,aoie•l+Jrrisr• �y��\O\/ �Nq%/.171 /fF.1d' N/!•OfE //S.OI'(,!) e A 09•//'45• •r.Sdo' L•II. 4/' wilt J.04-00W,f J -V,~, d•50 54'92• R•BOO' L• 1.72.01} y0�``6^. dada•/Oas7r/orap•!o)L•rss.ee• 'NIdg19'27'W 21.27' NI8•32'W (R) 75.48 d•t0•p4'14• R• JOW L•/Oh7/' I 10 'N / kills -LOCATION MAP F �lJh/J 70 yy r/eN L EG ENa jU <BLE TQC 'r r0 AS /NOCATEO • Ser A RCBAR L9.1202 WLIS o CALCULArC0 On/Lr j A 0 SECr[ON CORNER A5 J[/OWN a Or MAPS 37A II Or MAPS 75 (0) //E1 Cw 318 4y. (O.) /524 OR 408 ; fl[1 d/ Or MAP142 RA= OF BEAR/NGS rMC BAJLS Or BEAR/NGS AS rNE EAST L/NE Or -3 EC /1 7A*TV AS NOO.0/ O4 r. per (.f,) /@•diaS0a0o• •(cv)•/oL/•S?/o' o. MELJMNe7'57'Z5W 147.,14' / L A/Ei7•,1115 w 1/8.70' U9. 70%) BE/N6 A PoItT/ON OF LOT /!04 OF Ne7'39'25'w 243.E1' W88 •Di W (R) r�3�dTTE COUNTY OWFLW S LY/NG /N SEC. /8 i /7, T N/t/, BUILDING DEPARTMENlnRR � eurre c uNrY c ii RN/ATED FOR / QQ(/A/TY W"e'YOR'S CE?r/F/ ATG 77V/f MI♦ tow ^~, W/rN r[// +lpV[I/M!N// OA lY/ LYM• e/Vif/ON N// /lr /NO 101AL Of0/N/Nlf, aerro: SIMP7 rNE 40' NONEICLOCS/YE PUBLIC EASEMENT 0r,ERfD TOR OED/CAMAI /s NOT ACCEPTED dT TN/J T/ME, ' wi[ L •fVYfes. tw 4f/ Ierff COp•V7Y V(YO I I I I I I i i i i i i i i i ii a I l u °Arecxcdrrrce wi6 Rectcmizect Goad ProcNew and of a quaRty FrescribscD for the S--ecif+ed we in the Uniform Building., PUnbing & Ai d ComW end " moamw 00,0631W co -de;. P P R O ED CHET SK/NNER PW al c:NE/e C /I r/F/GD_ rA_ /liY /N O�pKlv� Of MOPS, /r P06f • // 7Nl q/p(/ly ee .VCT SA.'INNGO L•ovoocr .,t pqu+.et olcoparq flPu[ NLBY-BG Y er //,L,�q �o I II a [ I L•O7/t e[/ //f/OdV/r v/ d-v1,rf[/// /1 .II/Ne vwvvr/Nr/r RKO.00/O /N rW Off/[/ Of / f ,/Ul/f COr/N7Y RIfOiOI+ vNefQ ffR/OL NOM..fR • •., �arn�tart • �7vpin & Q•7.7aclalp TMs Set' or P10sis ar:cj ypaC:31C. vers MUSt ae ..ept on Aha ios at all timss and it is unlawful to •mica any chess or alleratiors 4r sram* wAM" wrl"m permisseil from the Depa; snt of ?ebur rY�. Cownty of &'op do 151 25/ 10, cFJ .PROVIDE APPROVED VENT AND ADEQUATE COMBUSTION AIR FOR HEATER VOR W.H o BUTTE CouM -I- y BUILDING D EPARTMENT APPROVED BUTTE COUNTY BUILDING DEPARTMENT APPROVED ------------ --------- -- ---------------- --------------------- -7 . ......... ............... ........... \10 e, cV L V mw Cllly-'Doov- 1 h . TABLE OF CONTENTS TOC Project Title..'........ Residence for.Varasteh. Date........ 09/15/94 Pro'ect Address 45 Skinner L � ........ ane Oroville CA Documentation Author... Neal Kuopus .Company ....... ......... CALCTECH Telephone .............. (916) 589-4219 Compliance Method...... I MICROPAS4 by Enercomp, Inc. Climate Zone ............ 11 MICR6PAS4` v4.02 File_-VARASTEH Wth-CTZ11S92 Program -TOC User#-MP1320 User-CALCTECH Run -Proposed Residence TABLE OF CONTENTS Report- Page FORM CF -1R................. 1 FORM MF -1R............. 4 FORM C -2R ................. 6 FORM C -3R ................. 9 HVAC SIZING ..... ......... 13 Y II I Y I 1 � Y " i CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Residence for Varasteh Date........ 09/15/94 Project Address........ 45 Skinner Lane Oroville CA Documentation Author... Neal Kuopus Building Permit Company ................ CALCTECH Telephone.............. (916) 589-4219 Plan Check Date Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Check/ Date MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence GENERAL INFORMATION Conditioned Floor Area..... Building Type........... Construction Type ... Building Front Orientation. Number of Dwelling Units... Number of Stories.. ...... Floor Construction Type.... Component Type Wall Door Wall Wall S1abEdge S1abEdge S1abEdge Roof 539 sf Single Family Detached New Front Facing 36 deg (NE) 1 1 Slab On Grade `(Package D) BUILDING SHELL INSULATION Insulation Assembly # of Interior R -value U -Value Location/Comments R-11 0.092 FRONT, BACK, LEFT R-0 0.330 FRONT ENTRY, TO GARAGE R-13 0.083 FRONT, BACK R-13 0.084 TO GARAGE R-0 0.900 SLAB EDGE R-0 0.720 SLAB EDGE R-0 0.550 SLAB EDGE R-19 0.047 FLAT CEILING FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Back (SW) 28.0 0.870 2 Blinds.Lt None Yes Metal Window Left (SE) 32.0 0.870 2 Blinds.Lt None None Metal THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments S1abOnGrade Yes 295 3.5 Exposed S1abOnGrade No 244 3.5 Covered CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.........., Residence for Varasteh Date........ 09/15/94 MICROPA34 x4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence Equipment Type Furnace ACSplit HVAC SYSTEMS Minimum Duct Duct Thermostat Efficiency._ Location R -value Type 0.73�O'AF_UE None R-4.2 Setback 10.00 SEER Attic R-41.2 Setback WATER HEATING SYSTEMS Number in Energy Tank Type Heater Type istribution Type System Factor Storage Gas Standard 1 0.60 EF SPECIAL FEATURES/REMARKS Tank External Size Insulation ' (gal) R -value 40 R-0 R-11 wall insulation at existing walls built in 1991 per Form 3s Glazing to be metal frame dual -pane with clear glass Glazing.U-values per CEC DEFAULT TABLES FAN.WALL.73: CEC MIN. REQ'T. WITH SETBACK THERMOSTAT REQUIRED AC.10.0: CEC MIN. REQUIREMENT HWH: STATE 40 GAL. SEV-40-PXRT LPG OR EQUIVALENT REQ'D. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... Residence for Varasteh Date.....:.. 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence COMPLIANCE STATEMENT This certificate of compliance lists the building features `and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and -the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special. Features/ Remarks section. DESIGNER or OWNER Name.... Ben Varasteh Company. Address. 45 Skinner Lane Oroville, CA 95966 Phone... (916)_589-4258 License. Signed.. - (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone.... Signed.. (date) FA r DOCUMENTATION AUTHOR Name.... Neal Kuopus Company. CALCTECH Address. 27 Wahoo Ave. Oroville, CA 95966 Phone... (916) 589-4219 Signed.. '� � .t-�1 � R//S q.± (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 4 MF -1R Project Tit.le.......... Residence for Varasteh Date........ 09/15/94 Project Address........ 45 Skinner Lane Oroville CA Documentation Author... Neal Kuopus Company ................ CALCTECH Telephone .............. (916) 589-4219 Compliance 'Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Building Permit Plan Check Date Field Check/ ec Date MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM MF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*p may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether then are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- - er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturers labeled R -Value. 'y!T *150(c): Minimum R-13 wall insulation in framed walls fU�lw►�� (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. PA 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces: designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards.��� 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Clcseable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -1R Project Title.......... Residence for Varasteh Date........ 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM MF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 150(i): Setback thermostat on all applicable heating systems. 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks).have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. jC,. sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers . 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation pump time switch. IJi� 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.). LIGHTING MEASURES Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. jC,. COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... Residence for Varasteh Date........ 09/15/94 Project Address........ 45 Skinner Lane Oroville CA Documentation Author... Neal Kuopus Company ................ CALCTECH Telephone .............. (916) 589-4219 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone.. ....... 11 Field Check/ Date MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence Energy Use (kBtu/sf-yr) MICROPAS4 ENERGY USE SUMMARY Standard Design Proposed Compliance Design Margin Space Heating.......... 18.72 17.05 1.67 Space Cooling.......... 17.77 17.31 0.46 Water Heating.......... 30.82 29.65 1.17 Total 67.31 64.01 3.30 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type..... ....... Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume........., Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... 539 sf Single Family Detached New Front Facing 36 deg (NE) 1 1 ReducedYear Slab On Grade 1 Special 4312 cf 539 sf 539 sf 539 sf 11.1 % of FA 8 ft BUILDING ZONE INFORMATION (Package D) Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) HOUSE Residence 539 4312 1.00 Yes Setback 2.0 n/a COMPUTER METHOD SUMMARY Page 7 C -2R Project Title........... Residence for Varasteh Date........ 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZllS92 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence Surface PERIMETER LOSSES Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments HOUSE 9 S1abEdge 28 0.900 R-0 No SLAB EDGE 10 S1abEdge 45 0.720 R-0 No SLAB EDGE 11-S1abEdge 29 0.550 R-0 No SLAB EDGE FENESTRATION SURFACES # of Vent SC SC Interior Area 'Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 24.0 2 Metal Slider 0.870 216 90 0.88 0.58 Blinds.Lt 2 Window 4.0 2 Metal Slider 0.870 216 90 0.88 0.58 Blinds.Lt 3 Window 32.0 2 Metal Slider 0.870 126 90 0.88 0.58 Blinds.Lt OVERHANGS AND SIDE FINS Window— Overhang Left Fin Right Fin— Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 24.0 4 6 2 0.7 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 4.0 2 2 2 0.7 n/a n/a n/a n/a n/a n/a n/a n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall, 100 0.092 R-11 36 90 Yes DW.11.2X4.16 FRONT 2 Door 20 0.330 R-0 36 90 Yes None FRONT ENTRY 3 Wall 56 0.083 R-13 36 90 Yes DW.13:2X4.16 FRONT 4 Wall 212 0.084 R-13 306' 90 No GW.13.2X4.16 TO GARAGE 5 Door 20 0.330 R-0 306 90 No None TO GARAGE 6 Wall 104 0.083 R-13 216 90 Yes DW.13.2X4.16 BACK 7 Wall 116 0.092 R-11 216 90 Yes DW.11.2X4.16 BACK 8 Wall 128 0.092 R-11 126 90 Yes DW.11.2X4.16 LEFT 12 Roof 539 0.047 R-19 0 0 Yes R.19.2X4.24 FLAT CEILING Surface PERIMETER LOSSES Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments HOUSE 9 S1abEdge 28 0.900 R-0 No SLAB EDGE 10 S1abEdge 45 0.720 R-0 No SLAB EDGE 11-S1abEdge 29 0.550 R-0 No SLAB EDGE FENESTRATION SURFACES # of Vent SC SC Interior Area 'Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 24.0 2 Metal Slider 0.870 216 90 0.88 0.58 Blinds.Lt 2 Window 4.0 2 Metal Slider 0.870 216 90 0.88 0.58 Blinds.Lt 3 Window 32.0 2 Metal Slider 0.870 126 90 0.88 0.58 Blinds.Lt OVERHANGS AND SIDE FINS Window— Overhang Left Fin Right Fin— Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 24.0 4 6 2 0.7 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 4.0 2 2 2 0.7 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD,SUMMARY Page 8 C -2R Project -Title ........... Residence for Varasteh .Date........ 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity R -value Location/Comments HOUSE 1 S1abOnGrade 295 3.5 2 S1abOnGrade 244 3.5 System Type 28.0 0.98 R-0.0 28.0 0.98 R-2.0 HVAC SYSTEMS Minimum Duct Efficiency Location Exposed Covered 4 Duct Duct R-value Efficiency HOUSE Furnace 0.730 AFUE None R-4.2 1.000 ACSplit 10.00 SEER Attic R-4..2 0.810 WATER HEATING SYSTEMS Number Tank External in Energy Size' Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas Standard 1 0.60 40 R-0 SPECIAL FEATURES/REMARKS ' R-11 wall insulation at existing walls built in 1991 per Form 3s R-13 wall insulation at new walls per Form 3s R-19 ceiling insulation required per Form 3 .Glazing -to be metal frame dual -pane with clear glass Glazing U -values per CEC DEFAULT TABLES FAN.WALL.73: CEC MIN. REQ'T. WITH SETBACK THERMOSTAT REQUIRED .AC.10.0: CEC MIN. REQUIREMENT HWH: STATE 40 GAL. SEV-40-PXRT LPG OR EQUIVALENT REQ'D. CONSTRUCTION ASSEMBLY Page 9 3R Project Title.......... Residence for Varasteh Date........ 09/15/94 MICROF.AS4'v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference Name . DW.11.2X4.16 Description ...: DF Wall R-11 2x4 16oc Type ........... Wall R' -Value ........ *11 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 1.6 inches on center Fraction ..... 0.15 Sketch of Construction Assembly LIST�OF CONSTRUCTION COMPONENTS Material Cavity Name Description- R -Value 0. FILM.EX r Exterior air film:.winter value 0.17 1. PLY.0.63 0.625 in plywood 0.77 2. BLDG.PAPER Building paper (felt) 0.06 3c. BATT.R11 R-11 batt insul (cavity = 3.5 in) 11.00 3f. FIR.2X4 2x4 in fir framing -- 4. GYP.O.50',: -0.50 in gypsum or plaster board 0.45 - I. FILM.IN.WLL Inside air film: heat sideways 0.68 " Total Unadjusted R -Values 13.13 .FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 /" 13.13 x 0.85) + (1 / 5.59 x 0.15) = 0.092 Btuh/sf-F Total R -Value: 1 / 0.092 10.92 sf-F/Btuh Frame R -Value 0.17 0.77 0.06 3.46 0.45 0.68 Ap"t CONSTRUCTION ASSEMBLY Page 10 3R Project Title.......... Residence for Varasteh Date........ 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference Name . DW.13.2X4.16 Description .... DF Wall R-13 2x4 16oc Type ........... Wall R -Value ........ 13 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16 inches on center Fraction ..... 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value 0. FILM.EX Exterior air film: winter value 0.17 0.17 1. PLY.0.63 0.625 in plywood 0.77 0.77 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. BATT R13,, R-13 batt insul (cavity = 3.5 in) 13.00 -- 3f. FIR.2g4 ' -2x4 in fir framing -- 3.46 4. GYP.0..50! 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values 15.13 5.59 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 15.13 x 0.85) + (1 / 5.59 x 0.15) = 0.083 Btuh/sf-F TotalR-Valuei 1 / 0.083 = 12.05 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 11 3R Project Title.......... Residence for Varasteh Date........ 09/15/94 MICROPAS4„v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference Name . GW.13.2X4.16 Description .... Wall R-13 2x4 16oc Type ........... Wall R -Value......... 13 sf-F/Btuh Framing Material ... FIR.2X4 Spacing ...... 16 inches on center Fraction ..... 0.15 Sketch of Construction Assembly - LIST OF CONSTRUCTION COMPONENTS FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ..U -Value: (1,/ 14.98 x 0.85) + (1 / Material x 0.15) = Cavity Btuh/sf-F Nrame''' Description R -Value 0. FILM.EX Exterior air film: winter value 0.17 1.. GYP.0..63` 0.625 in gypsum or plaster board 0.62 2. BLDG.PAPER Building paper (felt) 0.06 3c. BATT.R13„1 R-13 batt insul (cavity = 3.5 in) 13.00 3f. FIR.2X4 1 2x4 in fir framing -- 4. GYP.0.50'. 0.50 in gypsum or plaster board 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 Total Unadjusted R -Values 14.98 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total ..U -Value: (1,/ 14.98 x 0.85) + (1 / 5.44 x 0.15) = 0.084 Btuh/sf-F Total R -Value: 1 / 0.084 = 11.86 sf-F/Btuh Frame R -Value U . I / 0.62 0.06 3.46 '0.45 0.6R 5.44 CONSTRUCTION ASSEMBLY Page 12 3R Project Title.:;....... Residence for.Varasteh Date........ 09/15/94 MICROPAS4'v4.02 File-VARASTEH Wth-CTZ11S92 Program=FORM 3R User#-MP1320 User-CALCTECH' Run -Proposed Residence Reference Name . R.19.2X4.24 Description Roof R-19 2x4 240c Type .......... Roof R -Value ........ 19 sf-F/Btuh Framing 0 Material ..... FIR.2X4 Spacing ...... 24 inches on center Fraction 0.07 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value �O. FILM.EX Exterior air film: winter value 0.17 0.17 1. SHNGL.ASPHLT Asphault shingle roofing 0.44 0.44 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3. PLY.0.50 . 0.50 in plywood 0.62 0.62 4. AIR.RF.3.50 3.5 in & greater air space: heat flow up 0.80 0.80 5c. BATT.All .0 R-11 batt insul (cavity > 3.5 in) 11.00 -- 5f. FIR.2X4 2x4 in fir framing -- 3.46 6. BATT.R8.0 R-8 batt insul (cavity > 3.5 in) 8.00 8.00 7. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45, I. FILM.IN.RF Inside air film: heat flow straight -up 0.61 0.61 Total Unadjusted R -Values 22.15 14.61 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 22.15 x,0.93),+ (1 / 14.61 x 0.07) = 0.047 Btuh/sf-F Total R -Value: 1 / 0.047 = 21.38 sf-F/Btuh 9 HVAC SIZING Page 13 HVAC Project Title.......... Residence for Varasteh Date........ 09/15/94 4 Project Addr?s0........ 5 Skinner Lane Oroville CA Documentation Author... Neal Kuopus Company ................ CALCTECH Telephone .............. (916) 589-4219 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field C ec Date MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -HVAC SIZING User#-MP1320 User-CALCTECH Run -Proposed Residence GENERAL INFORMATION Floor Area.:............... 539 sf Volume.. . ............ 4312 cf Front Orientation.......... Front Facing Sizing Location............ OROVILLE RS Latitude... .... ........ 39.5 degrees Winter Outside Design...... 30 F Winter Inside Design....... 70 F Summer Outside Design...... 104 F Summer Inside Design....... 78 F Summer Range.... ..... 37 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 Description HEATING AND COOLING LOAD SUMMARY 36 deg (NE) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 6984 2790 Glazing Conduction ............... 2088 1357 Glazing Solar .................... n/a 2850 Infiltration ...................... 2453 1007 Internal Gain .................... n/a 1650 Ducts ............................. 0 965' Sensible Load .................... Latent Load ...................... 11525 n/a 10620 2124 Minimum Total Load 11525 12744 . Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's -responsibility to consider all factors when selecting the HVAC equipment. Page No. 1 DIRECTORY OF CERTIFIED STORAGE WATER HEATERS Updated 08/02/93 LPG & Oil (WOS) ------------------------------------------------ ------------------------------------------------ CALCTECH Equipment Finder v2.2 User # EF1320 ------------------------------------------------ Selection Criteria: 1 of 1261 Marked, 09/15/94 Rec Eff Rated Hght Brand Vol EF Stndby Input F Wdth R16 Date Model Number (gal) M M (Btuh) T (in) ? Added ------------------------- ------- ------------ --- --- - ----- --- ------ STATE SE*-40-PXRT*-** 40.0 0.60 85.0 40000 L 3.75 0 9302 0 00 o co TABLE OF CONTENTS TOC Project Title..:....... Residence for Varasteh Date........ 09/15/94 Project Address:....... 45 Skinner Lane Oroville CA Documentation Author... Neal Kuopus Building Permit Company.......... ..... CALCTECH Telephone .............. (916) 589-4219 Plan Check Date Compliance Method...... MICROPAS4 by Enercomp, Inc. Field Check/ Date r1 imate Zine-_ _ 11 MICROPAS4.'.v4.02 File-VARASTEH Wth-CTZ11S92 Program -TOC User#-MP1320 User-CALCTECH Run -Proposed -Residence TABLE OF CONTENTS Report Page FORM CF -1R................ 1 FORM MF -1R ................ 4 FORM C -2R ................. 6 FORM C -3R ................. 9 HVAC SIZING............... 13 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... Residence for Varasteh Date........ 09/15/94 P A 4 k' .L %J A ress........ 5 S inner Lane Oroville CA Documentaticn Author... Neal Kuopus Company................ CALCTECH Telephone .............. (916) 589-4219 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Check/ Date MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories. ...... Floor Construction �Type .... 539 sf Single Family Detached New Front Facing 36 deg (NE) 1 1 Slab On Grade (Package D) BUILDING SHELL INSULATION Component Insulation Assembly Exterior Type R -value U -Value Location/Comments _Wall R-11 0.092 FRONT, BACK, LEFT Door R-0 0.330 FRONT ENTRY, TO GARAGE Wall R-13 0.083 FRONT, BACK fWal.l R-1:3_�_0=. 0-8-4� TO -GARAGE S1abEdge R-0 0.900 SLAB EDGE S1abEdge R-0 0.720 SLAB EDGE S1abEdge R-0 0.550 SLAB EDGE Orientation Window Back (SW) Window Left (SE) Type SlabOnGrade S1abOnGrade Area U- (sf); Value '28.0 0.870 32.0 0.870 Exposed FENESTRATION # of Interior Pan- Shading/ es Description 2 Blinds.Lt 2 Blinds:Lt THERMAL MASS Area Thickness (sf) (in) Location/Comments Yes 295 3.5 No 244 3.5 Exposed Covered Over - Exterior hang/ Framing Shading Fins Type None Yes Metal None None Metal Area Thickness (sf) (in) Location/Comments Yes 295 3.5 No 244 3.5 Exposed Covered CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... Residence for Varasteh Date........ 09/15/94 MICROPA34 v4.02 File-VARASTEH Wth-CTZllS92 Program -FORM CF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R -value Type Furnace 0.730 AFUE None R-4.2 Setback ACSplit 10.00 SEER Attic R-4.2 Setback WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank TypeHeater Type Distribution Type System Factor (gal) R -value Storage Gas Standard 1 0.60 EF 40 R-0 SPECIAL FEATURES/REMARKS R-11 wall insulation at existing walls built in 1991 per Form 3s R-13 wall insulation at new walls per Form 3s R-19 ceiling insulation required per Form 3 Glazing to be metal frame dual -pane with clear glass Glazing U -values per CEC DEFAULT TABLES FAN.WALL.73: CEC MIN. REQ'T. WITH SETBACK THERMOSTAT REQUIRED AC.10.0: CEC MIN. REQUIREMENT - HWH: STATE 40 GAL. SEV-40-PXRT LPG OR EQUIVALENT REQ'D. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title..'........ Residence for Varasteh Date........ 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM CF -1R ,User#-MP1320 User-CALCTECH Run -Proposed Residence COMPLIANCE STATEMENT This certificate of compliance lists the.building features and performance specifications needed to comply with Title -24, Parts 1and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Ben Varasteh Company. Address. 45 Skinner Lane Oroville, CA 95966 Phone... (916) 589-4258 License. Signed.. (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... Neal Kuopus Company. CALCTECH Address., 27 Wahoo Ave. Oroville, CA 95966 Phone... (916) 589-4219 Signed.. Rf ,S-Jq _ (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 4 MF -1R Project Title.......... Residence for Varasteh Date........ 09/15/94 Project Address........ 45 Skinner Lane Oroville CA Documentation Author... Neal Kuopus Company ................ CALCTECH Telephone .............. (916) 589-4219 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Building Permit Plan Check Date Field Check/ Date MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM MF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturers labeled R -Value. *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). *150(d):. Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. Design- Enforce- erment Q_ 0 _Yu k' I R-131aft ice' 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with . Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. _r -JK_ 71�K- NA -rdr., -A;JIc- MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -1R Project Title.......... Residence for Varasteh Date........ 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM MF -1R User#-MP1320 User-CALCTECH Run -Proposed Residence SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 150(1): Setback thermostat on all applicable heating systems. 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114:.Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor.spa. 3. Pool system has directional inlets and a circulation pump time switch. Iyi} 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.). LIGHTING MEASURES Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... Residence for Varasteh Date........ 09/15/94 P t Add 45 Sk' L L s ro�ec es........ inner ane Oroville CA Documentation Author... Neal Kuopus Company ................ CALCTECH Telephone.............. (916) 589-4219 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field C ec Date MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 18.72 17.05 1.67 Space Cooling.......... 17.77 17.31 0.46 Water Heating.......... 30.82 29.65 1.1.7 Total 67.31 64.01 3.30 *** Building complies with Computer Performance *** Zone Type GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area.......... . Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... 539 sf Single Family Detached New Front Facing 36 deg (NE) 1 1 ReducedYear Slab On Grade 1 4312 cf 539 sf 539 sf 539 sf 11.1 % of FA 8 ft (Package D) BUILDING ZONE INFORMATION Floor # of Area Volume Dwell Cond- Thermostat (sf) (cf) Units itioned Type HOUSE Residence 539 4312 1.00 Yes Setback Vent Special Height Vent Area (ft) (sf) 2.0 ' n/a COMPUTER METHOD SUMMARY Page 7 C -2R Project Titl.e.......... Residence for Varasteh Date........ 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence Surface HOUSE 1 Wall 2 Door 3 Wall 4 Wall 5 Door 6 Wall 7 Wall 8 Wall 12 Roof Surface HOUSE 9 S1abEdge 10 S1abEdge 11 S1abEdge Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments 28 0.900 R-0 No SLAB EDGE 45 0.720 R-0 No SLAB EDGE 29 0.550 R-0 No SLAB EDGE FENESTRATION SURFACES #-of Vent OPAQUE SURFACES Interior Area'Pan- Frame Area U- Insul Act Surface (sf) es Type Solar Form 3 Location/ (sf) value R-val Azm Tilt Gains Reference Comments 100 0.092 R-11 36 90 Yes DW.11.2X4.16 FRONT 20 0.330 R-0 36 90 Yes None FRONT ENTRY 56 0.083 R-13 36 90 Yes DW.13.2X4.16 FRONT 212 0.084 R-13 306 90 No GW.13.2X4.16 TO GARAGE 20 0.330 R-0 306 90 No None . TO GARAGE 104 0.083 R-13 216 90 Yes DW.13.2X4.16 BACK 116 0.092 R-11 216 90 Yes DW.11.2X4.16 BACK 128 0.092 R-11 126 90 Yes DW.11.2X4.16 LEFT 539 0.047 R-19 0. 0 Yes R.19.2X4.24 FLAT CEILING - PERIMETER LOSSES HOUSE 9 S1abEdge 10 S1abEdge 11 S1abEdge Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments 28 0.900 R-0 No SLAB EDGE 45 0.720 R-0 No SLAB EDGE 29 0.550 R-0 No SLAB EDGE FENESTRATION SURFACES #-of Vent Sc Sc Interior Area'Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type. value Azm Tlt Only Shade Description HOUSE 1 Window 2 Window 3 Window Surface 24.0 2 Metal Slider 0.870 216 90 0.88 0.58 Blinds.Lt 4.0 2 Metal Slider 0.870 216 90 0.88 0.58 Blinds.Lt 32.0 2 Metal Slider 0.870 126 90 0.88 0.58 Blinds.Lt OVERHANGS AND SIDE FINS Window— Overhang Left Fin Right Fin— Area Left Rght (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 24.0 4 2 Window 4.0 2 U 6 2 0.7 n/a n/a n/a n/a n/a n/a n/a n/a 2 2 0.7 n/a n/a n/a n/a n/a n/a n/a n/a COMPUTER METHOD SUMMARY Page 8 C -2R Project Title.:........ Residence for Varasteh Date......... 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM C -2R User#-MP1320 User-CALCTECH Run -Proposed Residence Mass Type THERMAL MASS Area Thick Heat Conduct- Surface (sf) (in) Cap ivity . R -value Location/Comments HOUSE 1 S1abOnGrade 295 3.5 28.0 0.98 R-0.0 Exposed 2 S1abOnGrade 244 3.5 28.0 0.98 R-2.0 Covered HVAC SYSTEMS h Minimum Duct Duct Duct System Type Efficiency Location R -value Efficiency HOUSE LEurr ace - 0-._7.3.0_AFUE—None R-4.2 1.000 ACSplit 10.00 SEER Attic R-4.2 0.810 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage: Gas Standard 1 0.60 40 R'-0 SPECIAL FEATURES/REMARKS R-11 wall insulation at existing walls built in 1991.per Form 3s R-13 wall insulation at new walls per Form 3s R-19 ceiling insulation required per Form 3 Glazing to be metal frame dual -pane with clear glass Glazing U -values per CEC DEFAULT TABLES FAN.WALL.73; CEC MIN. REQ'T. WITH SETBACK THERMOSTAT REQUIRED AC.10.0: CEC MIN. REQUIREMENT HWH: STATE 40 GAL. SEV-40-PXRT LPG OR EQUIVALENT REQ'D. CONSTRUCTION ASSEMBLY Page 9 3R Project Title.......... Residence for.Varasteh Date........ 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZllS92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference Name DW.11.2X4.16 Description .. DF Wall R-11 2x4 16oc Type ............ Wall R -Value ........ 11 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16 inches on center Fraction ..... 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS . r Reference Name DW.11.2X4.16 Description .. DF Wall R-11 2x4 16oc Type ............ Wall R -Value ........ 11 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16 inches on center Fraction ..... 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value 0. FTI-LM.EX Exterior air film: winter value 0.17' 0.17 1. PLY.0.63 0.625 in plywood 0.77 0.77 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. BATT.Rll R-11 batt insul (cavity = 3.5 in) 11.00 -- 3f. FIR.2X4 2x4 in fir framing -- 3.46 4. GYP.0.50 0.50.in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68 0.68 Total Unadjusted R -Values 13.13 5.59 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Values (1 / 13.13 x 0.85) + (1 / 5.59 x 0.15) = 0.092 Btuh/sf-F Total R -Value: 1 / 0.092 = a 10.92 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 10 3R Project Title.:........ Residence for Varasteh Date........ 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference Name . DW.13.2X4.16 Description .... DF Wall R-13 2x4 16oc Type Wall R -Value ........ 13 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16 inches on center Fraction .'....'0.15 Sketch of Construction Assembly LIST OF CCNSTRUCTION COMPONENTS Material Name Description Cavity Frame R -Value R -Value 0. FILM.EX ' Exterior air film: winter value 0.17 0.17 1. PLY.0.63 0.625 in plywood - 0.77 0.77 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3c. BATT.'R13 R-13 batt insul (cavity = 3.5 in) 13.00 -- 3f. FIR.2X4, 2x4 in fir framing -- 3.46 4. GYP.0.50. 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.WLL Inside air film: heat sideways 0.68, 0.68 Total Unadjusted R -Values 15.13 5.59 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 15.13 x 0.85) + (1 / 5,.59 x 0.15) = 0.083 Btuh/sf-F Total R -Value: 1 / 0.083 = 12.05 sf-F/Btuh CONSTRUCTION ASSEMBLY Page 11 3R Project Title.......... Residence for Varasteh Date........ 09/15/94 MICRO?AS4 v4.02 File-VARASTEH Wth-CTZ11S92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference -Name GW.13.2X4.16 Description .... Wall R-13 2x4 16oc Type ........... Wall R -Value ........ 13 sf-F/Btuh Framing Material ..... FIR.2X4 Spacing ...... 16.inches on center Fraction ..... 0.15 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value 0. FILM.EX 1. GYP. 0.63 2. BLDG.PAPER 3c. BATT.R13 3f. FIR.2X4' 4. GYP.0.50 I. FILM.IN.WLL Exterior air film: winter value 0.625 in gypsum or,plaster board Building paper (felt) R-13 batt insul (cavity = 3.5 in) 2x4 in fir framing 0.50 in gypsum or plaster board Inside air film: heat sideways Total Unadjusted R -Values FRAMING ADJUSTMENT CALCULATION Cavity Framing U-17 0.62 0.06 13.00 0.45 0.68 14.9t3 Total U -Value: (1-/ 14.98 x 0.85) + (1 / 5.44 x 0.15) = 0.084 Btuh/sf-F Total R -Value: 1 / 0.084 = 11.86 sf-F/Btuh U.17 0.62 0.06 3.46 0.45 0.68 5.44 CONSTRUCTION ASSEMBLY Page 12 3R Project Title.......... Residence for Varasteh Date........ 09/15/94 MICROPAS4 v4.02 File-VARASTEH Wth-CTZllS92 Program -FORM 3R User#-MP1320 User-CALCTECH Run -Proposed Residence Reference Name R.19.2X4.24 Description .... Roof R-19 2x4 24oc Type ........... Roof R -Value 19 sf-F/Btuh Framing. Material ..... FIR.2X4 Spacing ...... 24 inches on center Fraction ..... 0.07 Sketch of Construction Assembly LIST OF CONSTRUCTION COMPONENTS Material Cavity Frame Name Description R -Value R -Value 0. FILM.EX Exterior air film: winter value 0.17 0.17 1. SHNGL.ASPHLT Asphault shingle roofing 0.44 0.44 2. BLDG.PAPER Building paper (felt) 0.06 0.06 3. PLY.0.50 0.50 in plywood 0.62 0.62 4. AIR.RF.3.50 3.5 in & greater air space: heat flow up 0.80 0.80 5c. BATT.RII.0 R-11 batt insul (cavity > 3.5 in) 11.00 -- 5f. FIR.2X4 2x4 in fir framing -- 3.46 6. BATT.R8.0 R-8 batt insul (cavity > 3.5 in) 8.00 8.00 7. GYP.0.50 0.50 in gypsum or plaster board 0.45 0.45 I. FILM.IN.RF Inside air film: heat flow straight up 0.61 0.61 Total Unadjusted R -Values 22.15 14.61 FRAMING ADJUSTMENT CALCULATION Cavity Framing Total U -Value: (1 / 22.15 x 0.93) + (1 / 14.61 x 0.07) = 0.047 Btuh/sf-F Total R -Value: 1 / 0.047 = 21.38 sf-F/Btuh HVAC SIZING Page 13 HVAC Project Title.......... Residence for Varasteh Date........ 09/15/94 Project Address........ 45 Skinner Lane Oroville CA Documentation Author... Neal Kuopus Company ................ CALCTECH Telephone.............. (916) 589-4219 Compliance.Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Che_c_k7 Date MICROPAS4 v4.02 File-VARASTEH Wth-CTZllS92 Program -HVAC SIZING User#-MP1320 User-CALCTECH Run -Proposed Residence GENERAL INFORMATION Floor Area ................. 539 sf Volume.. .. ............ 4312 cf Front Orientation.......... Front Facing 36 deg (NE) Sizing Location............ OROVILLE RS Latitude ................... 39.5 degrees Winter Outside Design...... 30 F Winter Inside Design....... 70 F Summer Outside Design...... 104 F• Summer Inside Design....... 78 F Summer Range..... ..... 37 F Interior Shading Used No Exterior Shading Used...... No Overhang Shading Used...... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Sensible Load .................... 11525 10620 Latent Load ....................... n/a 2124 Minimum Total Load 11525 12744 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 6984 2790 Glazing'Conduction ............... 2088 1357 Glazing Solar ..................... n/a 2850 Infiltration ..................... 2453 1007 Internal Gain .................... n/a 1650 . Ducts ............................ 0 965 Sensible Load .................... 11525 10620 Latent Load ....................... n/a 2124 Minimum Total Load 11525 12744 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Page No. 1 ` DIRECTORY OF CERTIFIED STORAGE WATER HEATERS Updated 08/02/93 LPG & Oil (WOS) CALCTECH --------------------=--------------------------- ------------------------------------------------ Equipment Finder v2.2 User # EF1320 ------------------------------------------------ Selection Criteria: - 1 of 1261 Marked 09/15/94 h . Rec Eff Rated Hght Brand Vol EF Stndby Input F Wdth R16 Date Model Number (gal) . (%) M (Btuh) T (in) ? Added ------------------------- ------- ------------------- - ----- --- ------ STATE 40.0 0.60 85.0 40000 L 0 SE*-40-PXRT*-** 3.75 0 r 9302 R t`un tr,: AGR CI '1 IAL STATE OF ACKNOWLEDGEMENT Building Division _ FOR RESIDENTIAL DEVELOPMENT Section 26-8.1' of the Butte 'Conary Code requires this acknowledgement be recd prior to issuance of a building - permit. 9 4-039 1 1 5 1 The property described herein is adjacent to land or included Rec Fee 9.00 I COP 1.50 within an area zoned for agricultural purposes, and residents Recorded I Check 10.50 of this property may be subject to inconveniences or Official Records I discomfort arising from the use -of agricultural chemicals, County of I including, but not limited to herbicides, pesticides, and . Butte I fertilizers; and from the pursuit of agricultural operations Candace J . ' Grubbs I including, but not limited to cultivation, plowing, spraying, Recorder I ping, and ung which occasionally generate 9: 4 9 a m 19 -Sep -94 I P U B L XX 2 dust,smolm, noise, and odor. Butte County has established agricultural zones which have as a priority use for.productive agricultural Purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience discomfort from normal, necessary farm operations. or All that real property. situate in the County of Butte, State of California, described as follows:. Date: State of Californi County of a On t/b personally appeared -PROPERTY OWNERS: (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) Ware subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(les), and that by hi0er/their signature(s) on the Instrument, the„a &&W,NM,AI;Wf of which the person(s) acted, executed the Instrument. j OFFICIAL, SEAL WITNESS my hand and official seal.N -. 1020872 D JUDITH M. WILLIAMS Z I NOTARY PU43LIC - CALIFORNIA N Q COUNTY OF 9UTTE MY CeInInlfNen Expires March Slgnat23, 1996Seal: w ...... DESCRIPTION , ALL THAT CERTAIN REAL PROPERTY SITUATE III THE STATE CALIFORNIA, COUNTY OF OF BUTTE, DESCRIBED AS FOLLOWS: PARCEL I: PARCEL 31 AS SHOWN ON THAT CERTAIN PARCEL 2rAP, RECORDED IN OFFICE OF THE RECORDER OF THE THE COUNTS' OF BUTTE, S'.0 STATE T CALIFORNIA, ON MARCH 6, 1987, IN BOOK 107 OF OF MAPS, .AT l?A 9. .PARCEL II• A NON—EXCLUSIVE EASEMENT FOR ROAD AND PUBLIC UTILITY PURpOSES OVER SKINNER LANE, AS SHOWN ON THAT CERTAIN PARCEL MAI.', RECORDED IN THE OFFICE Or THE RECORDER OF THE COirNTY Of, BC►TTE, STATE CALIFORNIA, ON MARCH 6, 1987, IN BOOK 107 OF OF MAPS, .AT PAGI;(S) 9. EXCEPTING THEREFROM ALL THAT PORTION LYI1rG WITHIN THE: BOUNcS PARCEL I, DESCRIBED'HEREIN. OF END OF DOCUMENT -15 10 P45/ cFJ T� PROVIDE APPROVED VENT AND ADEQUATE -COMBUSTION A!R FOR HEATER &/OR W.H BUTTE. COUNI-Y BUILDING DEPARTMENT APPROVED ]LOA A hoc •per I� e, � n c Gj p nam' N Tr o m -a CD /oj T o — .fes �• 6 .I x Q �G•O V ^z O I � A y ti i v y a CL w• = u .a► b CA hoc •per I� \ � n ��^^;= ,,TTcQ p •n \ L�:a !DJ• 00 � / oma, ��^^;= ,,TTcQ p Q o a o m -a CD /oj o �• N. a .fes �• 6 .I x Q ti O I � .. is 9jf �i • '� w o ��^^;= ,,TTcQ Q o a o m -a CD o �• N. .fes �• vIA2 ® B •� r �•�le °mA��\\� '" p}4?. �i ' ��. • n1 \tet. �• 4 izm R� �a° 0 o� ��^^;= ,,TTcQ Q o a o m -a CD F- 3 �. (CD 6 .I x O I � J RESIDENTIAL . 1 72-08-34 1373-91B,P,E VARASTEN, Ben 45 Skinner Ln, Oroville (new garage) of r p i t. �l �r T S OFFICE COPY Address �� GAS Meter B Date ELECTR C j,���I j ' Meter By / Date�_� / ' JOB FINALED (Date) G Signature J2'7 ��.�-� � :•vim,' 1 Z4, W7, V J=dk O = Not OK -=NotApplioabTe Not Ready MOBILE HOMES ' = Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements • 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap: / /"L"ft. / /"Nat. or/ /"L"ft./ /"LPG 7. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Mate DECKS, COVERS, CARPORTS, GARAG (Plans)OK except #'s FUpg, Requirements -Setbacks -Easements ootings; Soils -Size -Depth -Spacing -Connectors Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awry, Posts-Beams-Rftrs.-Coonectors 5. Alun/Awn.; Columns -Connections -Splice -Decal -Enclosures 4.. FrMg; Sils-Anchors-Studs-Rftrs-Trusses �1 141"Ext.; Steps-Doors-Landinqs Date " POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.;Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures-Pane Iboards- Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ✓=OK O=Not OK - = Not Applicable = Not Ready RESIDENTIAL (Single & Duplex) Date UNDERFLOOR (Plans) OK except #'s Date FRAMING (Continued) 1. &� ing-Setbacks- Ease ments-Flood-Slope 45. Hangers -Post Caps -Anchors -Connectors 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 46. Cing. Joist-Rftr. ties-Purlin-roof Brac-Truss-Shthng.-Ring. 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 47. Fireplace Ties or Type A Flue -Fireplace Throat clearance 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 5. Stemwalls, Main; Steel -Bloc kouts-Wrapped 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 50. Garage Fire Protection Framing 6a. Hold Downs and Special Anchors 51. Property Line Firewall & Openings 7. Slab; Steel -Wrapped 52. Ext. Doors -One 3' -Check Garage -3rd Story, 2 Exits 8. Piers -Fireplace Ftg.-Steel 53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers 10. Gas Pipe; Size -Anchors 55. Siding -Nailing Veneer 11. Water Pipe; Test -Anchor -Regulator -Service Test 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 12. Electric; Underground 57. Glazing Area -Glass Protection -Skylights -Plastic 13. Pienums & Ducts; Clearance -Material -Support -Ins. 58. Shear Walls; Nailing -Bolts 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 59. Insulation -Walls -Ceilings 15. Insulation 60. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s Date Card B-1 Date Card B-1 16. Water Htr.; Vent -Access -Combustion Air -Baffle Date FINAL (Plans) OK except #'s 17. Water Pipe; Test & Anchor -Nail Protection 61. Ext. Steps -Door & Sidelight Protection -Landings 18. D.W.V.; Test -Fittings & Anchor -Nail Protection 62. Smoke Detector 19. Shower Pan; Test, First Floor -Tub Access 63. Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 20. Test Tub & Shower, Second Floor -Tub Access 21. Gas Pipe; Size & Anchors 64. Bedroom Exiting 65. G.F.I. & Bath Fixtures & Tub Access -Spa Date Card B-1 Date Card B-1 66. Elec. Trim & Subpanel; Breaker Sizes & Labels Date Card B-1 Date Card B-1 67. Stairs & Rails Date ELECTRICAL (Permit) OK except #'s 68. Fireplace or Stove; Clearances -Hearth 22. Fixture & Transformer Clearance -Ins. Protection 69. Elec. Outlets at Wood Panel; Int. & Ext. 23. Elec. Receptacles Spacing -Lights & Switches at Doors 70. Kit.Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance 24. Size Boxes & No. of Conductors -Stapled 71. Elec. Outlets & Receptacles at Kit. Counter 25. Romex Installed Close to Edge of Studs & C.J. 72. Garage Fire Door; Swing -Landing -Closer 26. Equip. Ground made up w/Mech. Fastners-Bond Gas & Water 73. A.C. Duct in Garage -Damper 27. 2 Appliance Circuts in Kitchen & Conductor Size/GFI 74. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage; Above Floor-Mech. Protection 28. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 75. Plb., Elec. & Mech. Equip. Listed for Location 29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al. Insulated Neutral ❑ Yes ❑ No 76. Elec. Receptacles in Garage; (G.F.I.)-Romex Protection 77. Insulation -Foam -Looked in Attic ❑ Yes 30. Service -Riser Conductors & Ground -Main Disconnect 78. Guard Rails & Deck Construction -Post Caps 31. Equip. Clearances Panels-Motors-Mech. Equip. 79. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 32. Clothes Closet Light -Shower Light -Spa Light 33. Smoke Detector 80. Following instld.; Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑ Yes ❑ No Date Card B-1 Date Card B-1 81. Stucco; Brown -Finish Date Card B-1 Date Card B-1 82. A.C. Unit; Disconnect, Electrical, Plumbing Date MECHANICAL (Permit) OK except #'s 83. Vents Above Roof; Plbg.-Appliance-Fireplace.-Clearance to Openings 34. A.C. Ducts Insulation &Support 84. Water Well; Disconnect, Electrical, Plumbing 35. Vent Fan; Exhaust above insulation 85. Exterior Elec. Trim; G.F.I. Receptacle -Underground 36. Condensate Drain & Overflow; Size & Grade 86. Ventilation Throughout House 37. Furnance-Vent; Access -Comb. Air -Return Air Vent -115 outlet 87. Glass Protection 38. Attic Access & Platform if Furnance in Attic 88. Corrections from Previous Inspections 89. Gas Test -Meters Tagged; Gas -Electric 90. Water & Sewer Connected -C/O to Grade -HD Approval Date Card B-1 Date Card B-1 91. Energy Compliance Certificate -Other Certificates Date Card B-1 Date Card B-1 Date FRAMING (Plans) OK except #'s Date Card B-1 Date Card B-1 39. Sils, Proper Material & Anchors Date Card B-1 Date Card B-1 40. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound Date Card 8-1 Date Card B-1 41. Bearing Walls over Girders & Floor Nailing Comments at Final: 42. Draft Stop in Walls (rat proof) 43. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 44. Headers & Beam -Size & Bearing each time you visit job site) (NOTE: An entry must be made �.�-.::r��.i,d'cc.YCs.:._.••yy�,..�'�^`'�'r'•'a�,.ti+..^—�;,`y,..rv" .,�N'�...-.Y.,_c'+tisc"^y�-..s+'......r-:a. COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS f 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Croville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 1-W CORRECTION NOTICE a 7-7-71 PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation. please contact this office immediately. / l 3 i. I//// A' C (Fj A '-- Date 7- 2 y Inspector REV 11/91 COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, pleas# co),"gthis office immediately. 57/ZAzt> '-ry /2 o7'C--?--T/ a Date 7/ Inspector REV 11/91 COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 538-7541 747 Elliott Road, Paradise — Phone: 872-6307 CORRECTION NOTICE Fi PERMI N0. A routine inspection indicates that the following,yiolations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or eed additional explanation, please contact this office immediately. Date / o / Inspector COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 538-7541 747 Elliott Road, Paradise— Phone: 872-6307 CORRECTION NOTICE 1/G,/- Q_5 -�ef&'j /J73— OWNER - PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this mater,, or need additional explanation,, please contact/this office immediately. LA- G0 " L' f' c }; 44 .�r °A ,.q Date �Inspector -- 7 COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 938-7541' 747 Elliott Road, Paradise — Phone: 872-6307 — CORRECTION NOTICE ER MIT A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matteneed additional explanation, please contact this office immediately. "?19-45-0 � 1)0-4�- (=) - q'//16 - Date Date r / Inspector COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS .196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — PhonV538-7541 a 747 Elliott Road, Paradise— Phone: 872-6307 { CORRECTION NOTICE 3_-/ OWNER PERMIT NO. A routine inspection indicates that the following violations of County Ordinance a exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have.any question pertaining to this . a'1 matter, or need additional. explanation, please contact this office immediately. • l fi( S � CJI 11 CJ �2 S 74 Date 1 Inspector . a'1 Date 1 Inspector COUNTY OF BUTTE - j DEPARTMENT OF PUBLIC WORKS , 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Orovi Ile — Phone: 538-7541' 747 Elliott Road, Paradise— Phone: 872-6307 -CORRECTION NOTICE /nlCn nrn� A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter or need additional explanation, please contact this office immediately. Date - 3� Inspecto COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive - Oroville,;,�aliforrzia 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT "I ASSESSOR PARCEL NUMBER 72-08-34 ZONING BUILDING PERMIT OWNER + BEN VARASTEN TELEPHONE SO. FT. OCC, BUILDING VALUATION OWNER'S MAILING ADDRESS P.O. BOX 51656 CONTRACTOR'S NAME San 51 TELEPHONE CONTRACTOR'S MAILING ADDRESS Owner Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation is 14 Lnn Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER Nrmin LICENSE No. Plan Checking Fee $ Energy Plan Checking Fee $ 55.25 ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS Permit fee $ PLUMBING PERMIT Filing Fee10.00 Each Trap 3 2.00 6.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 5.00 USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome❑ Other pri det garage SPECT v Gas piping system 1 - 5 outlets 5.00 5,00 Building sewer 5.00 5.00 Mobile Home S I G I W 0.00ea TYPE OF WORK New DX Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other ❑ Describe work: _ new garage _ Permit Fee $ 36.00 Contractor ELECTRICAL PERMIT Filing Fee 10.00 00V OR Main service 100 AMP ORSLESS 10,00 10+00 Main service EA. ADD'L 100 AMP 2.50 2.5 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. No. Classification. 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) I, as the owner, am exclusively contracting with licensed contract- ❑ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING Occ�d o) OR ADONS. � ACC. BLDGS. Q��J , /20sgft 20.00 NEW CONSTR. U TI.OUTLET NON.RESID BRANCH CIRC ITS 2.50 ea /POWER APPARATUS e (SINGLE OUTLET CIR. I Ex. OCCupOUTLETS OR FIXTURES Occup(OUTLETS 2L SOS eAe90 FIXED APPLNS. OR I- Ex. Occup. OUTLETS (RESID.) EAJ 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring . g 15.00 Permit Fee $ 49-50 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. 1 shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed,revoked. Contractor MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 I Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue agai said ty in cons quence of the granting of this permit. / Q X Date Signature of Applicant — Owner& Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST TYPE TOTAL F E $ HAz. cuA — PARK SCHL — _ FLo cDF PAR Po Ho ssu This permit is hereby issued unaer the applicable provi- sions of the Butte County. Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTO F PUBLIC WORKS By � Date .5:2d'� IF/ PER EXPIRES Date ix -9 Receipt No. 89083 WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT i COUNTY OF BUTTE - DEPARTME;;J-�00 PUBLIC WORKS - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE.-OALIFORNIA 95965 - TELEPHONE: 916/538-7541 PERMIT APPLICATION DATA SHEET' �` Permit No. /� t OWNER !/ r.Z Ct ! � A. P. No. /� - QV 15 Proposed Building Use �01rCl C1 Building Inspector Date 5 At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED APPROVED 1. All items have bee .-s mitted. ............................. : ::.. . Plot plans in �dvplicate/ Iicate, signed by preparer of plans . —1� 3. Complete plans In Ica /triplicate, signed by preparer. of plans .. � 4. Complete enginee a plans and calcs, with wet signature on plans . 5. Hazardous Material Form ......................................... . 6. Energy Design Compliance and supporting documentation ......... 7. Statement of Intent for Non -Heated and AC Buildings .. 8. 'Engineered truss details and layout in duplicate (required prior to plan check) 9. Mobilehome installation data including manufacturer's installation instrudtions................................ 10. Fees of $ 11. Chico Urban Area fees paid ..... �.. .....'....................... 12. Park fees paid ...................1. ?............................. Sc, ool Distric fees paid .............. 1 Sanitation approval from r d Ly i 1 �� Health Department�TZ3,9-79 City of Chico plumbing permit.'.. ........... 16. Plot plan and business license approval from City of (see City for other requirements) 17. Planning approval for (A) Use: * (B) Parking: ...... 18. Improvements may be required. Contact Land Development Section DPW 19. Driveway permit (construction approval required prior to occupancy) 20. Pre -Inspection for required Pre-inspec. request to Building Inspector Ale) 21. Contractor's license information (No., Name Style, Classifications ... 22. Certificate of Workmans Compensation Insurance ...\............... 23. Owner -Builder Verification (Given to owner ❑, Mail to owner ❑) ..... 24. Recorded copy of Agricultural Acknowledgment Statement ......... 25. Letter of signature authorization ................................... 26. 1 27.. When you issue the permit, process as follows:" Mail to owner. Mail to contractor. Telephone and hold for pic up at office. Deliver w/inspector. Other q Applicant (59L'- Date Copy of Haz-Mat form sent Health Dept. Fire Dept. air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior to p�n,rrr;itiss a ce,:_(Circle new it not checked above). 1. Index permit for above items No. - 2. o. 2. Additional items required: Ai Contractor, designer, owner, was advised of above required data by_phone_�nail_co nter by date Contractor, designer, owner, was advised of above required da by_phone_mall_c unter by date Plans checked by Date Pans approved by Date 6 Sets of plans on hold in File cabinet AP folder Copy—DPW 12 TO Buildinc Department FROM: Environmental Health SUBJECT: Sanitation Clearance Owner Location AP# Plan Approved for: Sewaqe Disposal Water Supply Hold final for: Water Supply ^incl clearance O.R. for: Water Supply Clearance for —4 bedroom mobil. ome. Other NOTEVz *** Sanitarian Date COUNTY OF BUTTE - Department of Public Works 7 County Center Drive, Oroville, CA 95965 Phone: 916-538-7541 OWNER -BUILDER VERIFICATION Attention Property Owner: An 'owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the maj',Qxlabor and q�}aterials for construction of the proposed property improvement es or no) r'eS 2. I ave have not }`1Cy.V2 signed an application for a building permit force proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction: ,,II Name (�o✓Le _ Address City Phone Contractors License No. 4. .I plan to provide portions of this work, but I have hired the following person to coordinate supervise, and provide the major work: Name vn in P Address City Phone Contractors License No. ' 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: Name Address Phone Type of Work /Ub ✓i2 Signed: n \ Property Owner `Vasree , Social Security Number Date 5 x_91 NOTE: This Owner -Builder Verification is sent to you as required by.Sections 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are per- mitted to issue the permit. COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive - Oroville,, Califc;nla 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT ASSES oPA©� NUMB R ZONA BUILDING PERMIT ow R 'fie n a res t TELEPHONE .�—Q SO. FT. OCC. BUILDING VALUATION /j� V ©D f�( OVjJ7©MAI Lyr1G ADDRF�55�� 5— C TRACTOR'S NAME TELEPHONE COrUTRACTOR 5 MAILING ADDRESS l >' Fireplace . CON T UCTIOIN LENDER UNKNOWN C Total Valuation $ Filing Fee $ 1000 LENDER'S MAILING ADDRESS Permit Fee $ /10 Q ARCyi IST ECT OR ENGINEER '�e LICENSE No. Plan Checking Fee $ Ener Plan Checking Fee $ Energy g ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADORE o - Permit fee $ PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 6,00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 S DO Each qas water heater or vent 5.00 .9 , 0,0 USE OF STRUCTUR�P //�� SF ❑ Duplex❑ Mobilehome❑ I Other ✓t SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G W 0.00 ea TYPE OF WORK New W Addition ❑ Remodel ❑ Uti lities ❑ Installation ❑ Other ❑ Describe work: Permit Fee $ D Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 1001 OR LESS 100 AMP OR LESS 10.00 �� 0 Main service EA. ADO'L 100 AMP 2.50 � CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): El am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions -Code and my license is in full force and effect. License No. Classification, ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or. offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason oR ADDNST ( DWEACCLLIN G0ccu yz¢sgft 0Q, QQ NEW CONSTRU TI.OUTLET NON -R ESID BRANCH CIRCUITS) 2,50 ea — — �, POWER APPARATUS e _ (SINGLE OUTLET CIR. Ex. Occup(OUTLETS OR FIXTURES 2ALSeLo303o Ex. Occup. out LEPARESIO IREA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 9 15.00 Permit Fee $ S WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's -Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation Permit F $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date Signature of Applicant — Owner EJ Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST TYPE _ TOTAL FEE $j HAL. I CUA I PARK I SCHL I FLD I CDF I PAR I PD I HD. ISSUE This permit is hereby issued unser the applicable provi- sions of the Butte County. Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By Date PERMIT EXPIRES Date + ffL�: 3 Receipt No. WHITE-D.P.W.. YELLOW-ASeCSSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 7 County Center Drive, Oroville, CA 95965 PHONE: 916=538-7541 Ben Varasten P.O. Box 51656 San Jose, CA 95151 With reference to the above subject: DATE tia„ a i agi RE: building permit application x;1373-91 A.P. # 72-08-34 Attached is: .Application for permit Mobilehome Utilities Installation Sheet Building Plans Mobilehome Installation Information Sheet Engr. Calcs Typical Pian Sheet Owner -Builder Verification Form List of Codes Enforced OTHER /XX/ We need the following information: Permit application signedand completed where indicated with all copies returned. Fees of $ payable to Butte County Treasurer. Certificate of Workmen's Compensation Insurance or check exemption statement. Contractor's License Law information or check exemption statement. Complete plans in including plot plans. Plot plans in Structural details in ' Complete plans and calcs in by registered engineer or architect. Energy design including Street and drainage improvement plan approval from Land Development Section (DPW). sets of plans in accordance with the changes marked in.red. XX Sanitation approval from Butte County Health Department at: 196 Memorial Way, Chico XX 7 County Center Dr., Oroville Skyway & Elliott Rd., Paradise Planning approval from Butte County Planning Department, 7 County Center Drive, Oroville, for Completed Owner -Builder Verification form. Recorded copy of deed showing Recorded copy of agricultural acknowledgement statement. OTHER Label room uses, Should you have any questions concerning the above, please contact nave Wasney of this office. JFG/aj Yours very truly, William Cheff Director of Public Works J.F. Glander Chief Building Inspector .z w.� ' (0 cn -p D .moo CCm n(DNQ �<o�--An CA w e CDco � 3 coo CCD .. (b. ti� .otic SVR• �+. s vm2 � 9 y Sy ��� � C9;0.� hN �°�t3 y gyp• a� po C \ yu�ag8ga' Eo w � 0 � N °v O w.� ' (0 cn -p D .moo CCm n(DNQ �<o�--An CA w e CDco � 3 coo CCD .. (b. ti� .otic SVR• �+. s vm2 � 9 y Sy ��� � C9;0.� hN �°�t3 y gyp• a� po yu�ag8ga' w � 0 � N °v A POAc�nit . y �rw A V� S Oj ILI n� n � �-•'y. ��� 20 ''� am�snl nn po n � 6 �SzN z� ��� ztz m -251.10' z— aoz.os•��,� �` Z n � v- a. o 1� �•-m r Illlllllllllllllli' 0 J I' 7. poll 16 po- cr to 4n cr ck, poll 2A S� W10, c 2 _ C rx lywa� ooV 5���� ��CT I ' Pd UAID . -7—Ae 1914 PEI CnM� kZ11 S+lC-ET P,00( WALL,� CE ISIO& �VGC)AI 6vl;41N Ell %W' CZ Es4/eAivc- es - WA L L A 2,1111 6=.�AIcTE-7--/ _Es .-1 z'y o pP�C�1 2A -lq CE���rvo- -E-N SU/ATav C 11 VVALL BUTTE COUNTY BUILDJNC DEP APPRO �PTMENTVED i Q � V•� .T 1 LSA Y 0 . i W 9sCD.... 0 yO I o' 15'25' = 5 PROVIDE APP CVED VENT �l SAND ADEQuAtE CGki;Y i35T10N AIR FQR HEATER WOR W.H. co -- _ Garo.bz- hoc r8_ BUTTE COUNTY BUILDING DEPARTMENT APPROVED f I 0 _IX 0 Mandatory Measures Checklist: Residential MF -1R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the eotttPliarhce approach used. Items marked with an asterisk (•) may be superseded by mote stringau eomplramce requirements listed on the certificate of compliance. Wben this checklist is incorporated into the permit doGuw%the features toted shall be considered by all parties as binding minimum component performance specifications for Ute mandatory measures re whether they ashown dsewhae in the documents or on this Checklist only. �. DFSCRIPTION DESIGNER I ENFORCEMENT . Building Envelope Measures • §2.5352(a): Minimum ceiling insulation R-19 weighted average. §2.5352(br Loose fill insulation manufacturers labeled R -Value. • §2.5352(c): Minimum wall insulation in framed walls R -I 1 weighted average (does not apply to exterior mass walls). 12-5352(kr Slab edge insulation - water absorption rate no gmzer than 0.3%. water vapor transmission rate no greater than 2.0 permiinch. §2-5311: Insulation specified or installed meets California Energy Commission (CEC) quality standards. Indicate type and form. §2.5352(f): Vapor barriers mandatory in Climate Zones 14 and 16 only. §2.5317: Infiltration/Eicfiltration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit sir leakage. b. Doors and windows certified. c. Doors and windows weatherstripped: all joints and penetrations caulked and sesleA §2-5352(e): Special infdtmtion bartier installed to comply with §2.5351 mecu CEC quality standards. §2-5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: a Tight rotting. closeable metal or glass door b. Outside air intake with damper and control e. Flue damper and control 2. No continuous burning gas pilots allowed. HVAC and Plumbing System Measures §2-5352(8) and 2-5303: Space conditioning equipment siring: attach akulationt. §2-5352(h) and 2-5315: Setback thermostat on all applicable heating systems. ' §2-5316(a): Ducts constructed. installed and insulated per Chapter 10.1976 UMC. §2-5316(b): Exhaust systems have damper controls. §2-5314(c): Gas-fired space heating equipment has intermittent ignition devices. 12-5314: HVAC equipment. water heaters. showerheads and faucets certified by the CEC. i2.5352(i): Water heater insulation blanket (R-12or greater) orcombimA interior/exterior insulation (R-16 or greater): fust 5 feet of pipes closest to tank insulated (R-3 or greater). §2.5312(Exccption 1): Pipe insulation on steam and steam condensate mum At recirculating piping. §2-5318(d): Swimming Pool Heating I. System has: a. On/off switch on heater. b. Weatherproof instruction plate on heater: e. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. Lighting and Appliance Measures 62.5352(1): Lighting - 25 lumens/watt or greater for general fighting in kitchens and bathrooms. 12-5314(c): Gas fired appliances equipped with intermittent ignition devices. 12.5314(a): Refrigerators. refrigerator -freezers. freezers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. CO1Vi U"CE STATEMENT This certificate of compliance lists -the building features and performance specifications needed to comply with Title 24, Chapter 2-53 andnae 20. C'ha* 2. subcha W4. Article 1 of the California Administrative code. This certificate has been signed by the individual with overall design respensibility and the building owner. who shall retain a copy of it and transmit the certificate to any subsequent purchaser of the building. Name: Tttle/l U= Address: Telephone: t.ic. N: (signature) Documentation Author Namc: TitklFirm: Building Owner Names Address: Telephone: (date) (signawoe) Enforcement Agency Name: Agency: Tekplwnc (date) D�� i� � _ - • .suite county LAND OF NATURAL WEALTH AND BEAUTY DEPARTMENT OF PUBLIC WORKS WILLIAM (Bill) CHEFF, Director .'; _, sir'' + • ••'•+ , 7 COUNTY CENTER DRIVE 2 OROVILLE, CALIFORNIA 95965 Telephone: (916) 536-7541 RONALD D. McELROY Deputy Director RE: Building Permit No. Expiration Date (A.P. No. ) With reference to the above subject, our records indicate that your Building Permit on the above date. Building permits are valid for one year and should construction be started but not completed by the expiration date of the permit, the permit shall be renewed for 2 the original Building Permit Fee (plus a $10.00 "Filing Fee"). The renewal permit will extend the Building Permit for an additional year from the original expiration date. Should you not renew your permit within thirty days of the expiration date, it cannot be renewed and all work must cease until a new building permit is issued. If your construction is completed or should you have any questions concerning this matter, please contact the office. For your convenience, we are enclosing a renewal application form and owner - builder form to be completed and signed by you where indicated and returned to this office together with the fee shown. Please return all copies of the application form. Thank you for your prompt attention concerning this matter. JFG:aam Attachments: Permit Application Owner -Builder Information Owner -Builder Verification cc: Building Inspector - Yours very truly, William Cheff Director of Public Works F. Glander ief Building Inspector Chico - 196 Memorial Way/891-2751 Paradise - 745 Elliot Rd./872-6307