Loading...
HomeMy WebLinkAbout072-310-006r _\ I ra k .17 FI' S of Oro-Forbestown RE of Feather Falls Rd., Oro. Permit 2996-73P,E j (utilities for MH) AP 72-31-06 y LOEFFLER �.. •;:'o-F.or.bneztow � � ,.. � ..Rd,. -2-Mi.., .E . of Fea-ther Falls Rd, Oroville Permit# 3354-74P,E ���'� ���� (replace permit# 2996-73) % AP CONTR: Cu.rley's Trailer Towxi , Oro, Permit# 2177-75MHI I s suedZ ELEC. GAS SUPPORT STAUCTU REQe 140 11PACT I ON TEST RM [4-0 0 i r- PERMIT NO. E M MH UTIL. PERMIT NO. 3354-74P,E Y PERMIT EXPIRES �—oJ ,,OWNER Robert F. Loeffler CONTR. n OCATION (A.P. 72-31-06 ) NIS' Oro-Forbestown Rd, 2/10 mi. E. of Feather•Ealls Rd, Oroville on Temp. Power Pole Called PG&E Temp. Elec. Serv. Called PG& Temp. Gas Serv. Called PG&E JOBG J FINALED (Date) (Signature) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) Setback Firewall Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor Stemwa1 P Sidinq To out Slab Roof Sheathing Water Piping Piers Roofing Sewer 014 Garage Fdn. Vents Fixtures Footings Garage Vents Water Htr. Stemwall Slab Prov. for physically handicapped Heaters Appliances Carport Footings Conformance of ex. structure Gas Piping & T Temp. Gas Slab Final Sanitation Patio. FIREPLACE Final 91 Footings Footing Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam FIRE SPRINKLERS Motors Framing Test Water Htr. Stucco Final Subpanels Mesh MECHANICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final DATE REMARKS OR CORRECTIONS PLUMBING ve -- K / ELECTRICAL COUNTY OF BUTTE — DJEPAR7MENT OF PUBLIC WORK 7 County Center Drive — Oroville, California 95965 Telephone: 534-4541 V APPLICATION AND PERMIT autnunce representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. X r Date `7� Signre of Permitee or Agent Receipt No. 0 7 �z White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By Date4ml9/7 s� BuifdH permit expires Date........... �(7„s BUILDING Owner �- SQ. FT. OCC. BUILDING VALUATION Mailing Address 310/ 519l-?I)vO 69- / 'Qywo `-OQ 4 Telephone No. Fireplace Contractor © LV A/ 67 Total Valuation Mailing Address Permit Fee Plan Checking Fee &/or Penalty Telephone No. Permit Fee $ $ Building Address d , DF D L PLUMBING No. @ FEE PERMIT FILING FEE $2.00 • (,b // C D L7S D G� '2�0 /GE ,C ; O Each Trap 1.50 /j Repair drainage or vent piping 1.50 Water piping 1.50 Each gas water heater or vent 1.50 A. P. No. �— �� —Q s !�• Zon g 1.99 Gas piping system 1 - 5 outlets 1.50 S Each additional outlet .30 F W. Sanittatlon Fire Dept. Fire Zone Use Permit Building sewer 5.00 OQ EQA Parking Plans Parcel Declaration Parcel Ma P 60' R/W Im roveme is P Lawn sprinkler system 2.00 n - 6 Plans -oAp Parc pproval Pla proval Permit Fee $ Q.�O $ /� �0, OC NEW r-1ADDITION❑ UTILITIES iL� OTHER ❑ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 , o6 E Cir /� � 6 73'"S&� Main service incl. 1 meter , r7-3 Additional meters, each 1.00 Single Family ❑ Duplex ❑ Mobil Home Others ❑ Sub -panel (12 or less) (more than 12) Range, Cook -top or Oven 1.00 Water Heater or Space Heater 1.00 Light fixtures 20 X010 Receps., switches & fix outlets 2GTd,2Y CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: Hood, Ex. Fan or F.A. Furn. Motor 1.00 Evap. cooler, gar. disp. or D.W. 1.00 Air conditioner or heat pump Water pump 7ZIR 1,06 Mobil Home Facilities 5.0004 Temp. Power Pole 5.00 License No. Classification Misc. wiring r 1 am exempt from the Contractors License Laws of the State of California. \ Permit Fee $ 06 $12, 10 WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑ I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. \ Ja(�71 I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ TOTAL PERMIT FEE h $ .2, 104 autnunce representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. X r Date `7� Signre of Permitee or Agent Receipt No. 0 7 �z White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By Date4ml9/7 s� BuifdH permit expires Date........... �(7„s C4 COUNTY OF BUTTE — DEPARTMENT -OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 Telephone: 534-4541 APPLICATION AND PERMIT durnunce ytTrtsentatives or the Uounty of tsutte to enter upon the above -me ti • ed pro ert r inspe i n purposes. X� Date Signature of Permitee or nt Receipt No. White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By Date_ -Z -7 - 7 Building permit expires Date -2-7 - -) Z. BUILDING Owner Ka I aoct r SQ. FT. OCC. BUILDING VALUATION Mailing Address 41dg, Tel o No. b v Fireplace Contractor Total Valuation Mai I i ng Address Permit Fee Plan Checking Fee &/or Penalty Telephone No. Permit Fee Building Address PLUMBING No.1 @ FEE PERMIT FILING FEE $2.00 aea 1z"L Each Trap 1.50 / Repair drainage or vent piping 1.50 Water piping 1.50 0 0 .e 01PEach gas water heater or vent 1.50 -72--3 -f A. P. No. -—L g' g Gas piping system 1 - 5 outlets 1.50 , Each additional outlet .30 _Q F kWo San' ion Fire Dept. Fire Zone Use Permit Building sewer 5.00 (� EQA Parking Plans Parcel Declaration Parcel Ma P 60' R/W improvements provements Lawn sprinkler system 2.00 9• PI ansns Recd Parcel of Plans oval Permit Fee $ O ®� NEW ❑ ADDITION ❑ UTILITIES 7f OTHER ❑ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Main service incl. 1 meter p Additional meters, each 1.00 ( Single Family [J Duplex ❑ Mobil Home 2 Others ❑ Sub -panel (12 or less) (more than 12) Range, Cook -top or Oven 1.00 Water Heater or Space Heater 1.00 Light fixtures yal_ bio Receps., switches & fix outlets 2023 CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: Hood, Ex. Fan or F.A. Furn. Motor 1.00 Evap. cooler, gar. disp. or D.W. 1.00 Air conditioner or heat pump Water—pump oe> Mobil Home Facili ies 5.00 G Temp. Power Pole 5.00 License No. Classification Misc. wiring I am exempt from the Contractors License Laws of the State of California. Permit Fee $ 2. 0"' y ®� WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑ I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. ( I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. 1 certify that I J4ave read this application and state that the above information i c rrect. I agree to comply to all County Ordinances and State Xa s relating to building construction, and hereby MECHANICAL No. @ FEEPERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ TOTAL PERMIT FEE $ durnunce ytTrtsentatives or the Uounty of tsutte to enter upon the above -me ti • ed pro ert r inspe i n purposes. X� Date Signature of Permitee or nt Receipt No. White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By Date_ -Z -7 - 7 Building permit expires Date -2-7 - -) Z. 0 I)PP(loy .foo t L All utility connections' sl located within 4 ft. outsideherear third section of the mobile home on the left (road) side of the mobile home. 1-40,6./•-�• The tg. Setback shall be'5 ft. from the side property; line and 50 ft. from the centerline of the road, permitting a maximum of- a 2. ft. eave overhang. Septic system B�t�t to be as _pe utte Count quirements, y Health Dept. Re. . BUTTE COUNTY 3UILDING DEPARTMENT APPROVE fhis set of plans and specifications MUST b kept on the job at all times and it is unlawful to make any changes or alterations on same without written _.permisson from the Department of Public ` Q Works, County of Butte. 0� n Ok Not2TO Lr" M7- 013E F IRU an FFteI a � �PERMIT NO. 2177-75MHI P E M MH UTIL. PERMIT NO. PERMIT EXPIRES — 76o OWNER R.obertLoeffler CONTR. Curley' s Trailer Towing, Oroville LOCATION (A.P. 72-31-06 ) i n/s Oro-Forbestown Rd, 4 mi. e. of Feather Fall; Rd., Oroville t' 1 Temp. Power Pole I Called PG&E .; ..Iarap. Elec. Serv. l—" 0 Called PG&E Temp. Gas Serv. h� -' �✓ r 7� +y Called PG&E tFIINALED ✓ 3d r7� (Date) (Signature r .. COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) PLUMBING Setback Firewall Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor Stemwall Siding To out Slab Roof Sheathing Water Piping Piers Roofing Sewer Garage Fdn. Vents Fixtures Footings Gara a Vents Water Htr. StemwaI l Slab Prov. for physically handicapped Heaters Appliances Carport Footings Conformance of ex. structure Gas Piping & Test Temp. Gas Slab Final Sanitation Patio FIREPLACE Final Footings Footing ELECTRICAL Masonry Walls Throat Rou h Reinf. Steel Final Fixtures Bond Beam FIRE SPRINKLERS Motors Framing Test Water Htr. Stucco Final Subpanels Mesh MECHANICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final DATE REMARKS OR CORRECTIONS_ S TO Building D..e partmer_t Environmental Health / 7� RE: Sewageand/or ?Fater Clearance 3 � 5 4 74. /0e fns. �Sk'�s 1.0 0 7,,?^ 31 -06 LOCATION A. P,# Has been approved-for- ----_ ° SDIAGE DISPOSAL0lC V.'ATER SUPPLY �� r MOBILEHOME INSTALLATION INSPECTION CHECK LIST 1. Is the mobilehome located with required separation from lot lines and buildings and generally conform to plot plan? Yes No .2. Does the mobilehome have required clearances above ground? (Sec.5085) Yes I No 3. Are footings and supports properly sized, spaced, and braced as per approved plans? (Note possible variation at spring shackles.) (Sec. 5082 & 5083) Yes No 4. Is the mobilehome level? (Sec. 5088) ''es)L No 5. If more than a single unit, are crossover connections properly installed? (Sec. 5088) Yes No 6. Water A. Is fle ible connector of adequate size and properly installed (1/2" ID min.)? (Sec_. 5566) YesNo B. Test - Does water piping withstand working pressure or 50 lbs, air test? Yes,C No C. Backflow - If coach is not State of California approved, does station have backflow device and pressure -relief valve? Yes No P /� r 7. Wastes and Drains A. Is connection made with Schedule 40 DWV and have flex connectors at.each end? Yes No B. Does it have.minimum" per foot slope and is it properly supported? Yes No C. Are any leaks detected in drainage system after running 3 -gallons of water through each. fixture including washing machine standpipe?, .Yes No D. If coach is not Stat W f California' approved, does station have required trap and vent? Yes No j��/W r 8. Gas Piping and Gas Vents A. Connector - Is mobilehome connected to the gas supply with an approved 3/4" minimum mobilehome connector not more than 6 ft. long? Note: All piping is to be at least as large as the mobilehome gas line inlet without reductions other than the mobilehome connector. Yes No B. Test OK as per following procedure? YE`s_4 No_ C._�= Open all appliance connector valves. / 2. Shut off appliance burner and pilot valves. ,-,,-3. Air test with manometer to 10"-14" water column, or test with slope gauge (minimum .6oz.-maximum 8 oz.) calibrated in tenth pound increments.. Test for 10 min, without drop. r Connect gas meter to mobilehome with connector, turn on gas, test connections with soapy water. C. Are all appliance vents properly installed? Yes_g_ No. 9. -Electrical A. Is service large enough to provide ade.q uate, amperage. to mobilehome (must equal rating of mobilehome with a minimum of 100 amp) and other facilities on lot, i.e., water pumps, garage, cabana, etc.? Yes No B. Is there proper clearances around panels? YesV No C. Is power supply cord or feeder assembly properly fused? Ye S4 No D. Is continuity test satisfactory as per the following procedure? Yes No I—f De -energize electrical wiring system of the mobilehome at the pe estaI. 2. Make sure that the power supply cord or feeder assembly conductors, including neutral conductor, have been disconnected. Switch all breakers and switches in the mobilehome to the "on" position. G Connect one lead of a test instrument to the mobilehome grounding conductor -and apply the other lead to each mobilehome supply conductor, including neutral. All non-current, carrying metal parts of the mobilehome (aluminum siding, gas line, water line), including fixtures and appliances, shall be tested for continuity from such equipment and the grounding conductor. L6 Upon completion of the above procedure, the power supply cord or feeder assembly conductors shall be connected to the site service equipment. A further continuity test shall then be made between the grounding electrode and the chassis of the mobilehome. Upon satisfactory completion of theelectrical tests; the lot or site service equipment may be approved for energizing. 10. Is job card signed by Health Department for water and sanitation? 11. If everything okay, sign off card and tag services. MOBILEHOME DATA Manufacturer and/or Namestyle &*-00G/1 6r�, Length 4Width 2 - Vehicle Serial No. State Identification No. Additional Information or Comments: TO IL COUNTY OF BUTTE DtPARTMENT OF PUBLIC WO KS 7 County Center Drive — Oroville, California 95965 6? �✓ 7� Telephone,, 534-4541 APPLICATION AND PERMIT authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. Date Signature of Permitee or Agent Receipt No. /Vc) White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By , � Date Rg permit expires Date _ �Z�� G BUILDING Owner SO. FT. OCC. BUILDING VALUATION Mailing Address app S4,0 Jz-J1y - y swiTelephone geV � No. Fireplace ContractorZ 's �Q/ j� �p�,� Total Valuation Mailing Address 7rJ r- Permit Fee Plan Checking Fee &/or Penalty Telephone No. Permit Fee Building Address u 5117 .�ovPLUMBING No.1 @ FEE PERMIT FILING FEE $3.00 Each Trap 1.50 d� Repair drainage or vent piping 1.50 Water piping 1.50 Each gas water heater or vent 1.50 A. P. No. Z/"G5 Zoning & Planning Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 F 9arri•tetrvrr FireDept. Fire Zone Use Permit Building sewer 5.00 EQA Parking Plans Parcel D 6laration Parcel Ma p 60' R/W Im rovemen p Lawn sprinkler system 2.00 Bldg. Plans filecd Parcel pproval Plans AR4foval Permit Fee $ $ NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER ® ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Main service incl. 1 meter C �� Additional meters, each 1.00 Sub -panel (12 or less) (more than 12) Single Family ❑ Duplex ❑ Mobil Home ® Others ❑ Range, Cook -top or Oven 1.00 Water Heater or Space Heater 1.00 Light fixtures 60((62 10 Receps., switches & fix outlets CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style,qf:// ` —y-� ` i► aQ lu r �F �t L.a. Hood, Ex. Fan or F.A. Furn. Motor 1.00 Evap. cooler, gar. disp. or D.W. 1.00 Air conditioner or heat pump Water pump Mobil Home Facilities 5.00 Temp. Power Pole 5.00 License No.?,( -:3 I �ea`L Classification 6, Misc. wiring ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the, provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. ❑I certify that in the performance of the work for which this permit ,is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation +2.00 Hood Permit Fee $ $ 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby %1 X 4;e D 3D O r TOTAL PERMIT FEE $ authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. Date Signature of Permitee or Agent Receipt No. /Vc) White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By , � Date Rg permit expires Date _ �Z�� G N COUNTY OF BUTTE Department of Public Works 7 County Center Drive Oroville, California I J PHONE: 534-4541 Co $ 0-0 1� Length. () C), 1. 2. 3. 4. 5. 6. 7 L.*M I Lot Facilities MOBILEHOME INSTALLATION INFORMATION Plot plan dimensioned, location of mobile and utility connections? Yes_ No Electrical.service equipment ainpacity2-o Circuit breaker ampacity ls,,� Permanent Wiring Connection(/ Ampacity _Lb() Receptacle Ampacity ----- Gas: Natural ----- LPG Gas riser size �I Drain inlet size Water riser size Are utility connecti ns located outside the rear 1/3 of the mobilehomec ithin 4 feet of the left wall? YL-.--__j,/No If not, shoti3 di.mensions.above. Is the mobilehome cleat of septic tank, leach fields and located utside p tic utility easements? Yes No Do you propose to do otr w heork n the, property other than the mobilehome installation w ich will require a permit? Yes No If so, specify Mobilehome Data 1. Length (nb Width� 2 Manuf acturer -13jLn� 1n. nwP� Vehicle Serial No. S_ 44 Insignia Control No. 2. Feeder assembly ampacity fo6 Conduit size Ir ' Power supply cord (amP,s.) 3: Gas inlet size -:0 1 Mobilehome connector size (, Capacity 4. Drain connector: describe on reverse side 5. Water connector: describe on reverse. side 6. Designed loads: psf. . (only for mobilehomes manufactured after October 7, 1973) 7. Manufacturer's nst.allation instructions? Yes No 8. Will the mobile home be installed on a separate suppo t structure. Yes No *For plans and specifications of support system, see other side. LOAD BEARING S POTS ADDITIONAL C011ED!:7"N'TS Drain Connector, Describe s pun 9 CC ��. AAf? l:J LOAD BEARING SUPPORT AND -VOQTING„INFO?.RATION /' Tr Pier Spacing Used /; Maximum Pier Load `` Maximum Column Load (multi -units only) Soil Bearing Capacity. 3 Footing Dimension Used, I � TYPE OF PIER USED / Steel Concrete Concrete Block V ` Other l TYPE OF FOOTINGMATT'RIAL USED Pressure Treated Wood Concrete Redwood (Grade) Yid Other Approved Type BUTTE COUNTY ur I/� BUIL^INr DEPiARTMEW APPROVED I