Loading...
HomeMy WebLinkAbout078-280-054'4w rUSSEN SAVINGS :& -LOAN- - - - - - - 5707B� 437 5P _5 i ?455 V-6 Rd., Oroville CONTR: Harmony B1drs.,,P.O_ �*. Box 578, Orovil, (TRANSFERRFp FROM John Voorhees, Permit #37 �, le "I �o r '4w rUSSEN SAVINGS :& -LOAN- - - - - - - 5707B� 437 5P _5 i ?455 V-6 Rd., Oroville CONTR: Harmony B1drs.,,P.O_ �*. Box 578, Orovil, (TRANSFERRFp FROM John Voorhees, Permit #37 �, le "I �o i F 36=022-4.5 2076-89B E 1 DAVIDSON, Jim -- 2455 V-6 Rd, Oroville C i i(convert garage to living area)SF f _ _ • ASSESSOR PARCEL LOCATION 7W 7 o Temp. Power Pole x Called PG&E i Temp. Elec. Service Called PG&E Temp. Gas Service Called PG&E JOB FINALED (Date) ` Signature = OK 0 = Not OK = Not Read�yable MOBILE HOMES MISCELLANEOUS Date MOBILE HOME UTILITIES (Plans) OK except #'s Date DECKS,COVERS,CARPORTS,GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support -Sketch 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Sewer; Location -Test -Fall -C/O -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4. Wood Awn.; Posts-Beams-Rftrs.-Connec.- Shthg.-Rfg.-Bracing 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 6. Gas; Location -Test -Wrap: / /"L"ft. / /"Nat. or/ /"L"ft./ /"LPG 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Utility Clearance 7. Elec. 8. Frmg; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh Card -Bt Date Card -81 • Date 10. Roof; Shthg-Roofing Card -Bt Date Card -61 Date 11. Ext.; Steps -Doors -Landings Date MOSILEHOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements Card -Bt Date Card -B1 Date 2. Footings; Size -Spacing -Marriage Line Card -Bt Date Card -81 Date 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances Date POOLS (Plans) OK except #'s 5. Drain; MH Test -Fall -Flex Connector 1. Setbacks -Easements 6. Water; MH Test -Regulator -Connector 2. Soils; Compaction -Structure Stability 7. Water and Sewer Connected -C/O to Grade -HD Approval 3. Pool Structure; Steel -Connections -Thickness - Dead Men -Lining 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 4. Elec.; Receptacles and Lighting, Distances-GFI 10. Cert. of Occupancy 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.;Ground ing; Equip. w/5' -circulating Equip. -Pool Lghtg. Boxes -Enc losures-Pan elboard s -Ins. to Main in Conduit Card -Bt Date Card -B1 Date Card -1211 Date Card -B1 Date 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Card -B1 Date Card -B1 Date Card -131 Date Card -B1 Date = VK 0 = Not - =Not Applicable RESIDENTIAL (Single and Duplex) = Not Ready Date UNDERFLOOR (Plans) OK except #'s Date FRAMING (Continued) 1. Zoning -Setbacks; -Easements -Flood -Slope 45. Hangers -Post Caps -Anchors -Connectors 2. Ftg., Main; Soils-Steel-Elec. Grnd.-/ P' Ftg. Depth 46. Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfng. 3. Ftg., Garage; Soils -Steel-/ P' Ftg. Depth 47. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 4. Ftg., Porches & Decks; Soils -Steel-/ /"Ftg. Depth 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 5. Stemwalls, Main; Steel-Blockouts-Wrapped 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 50. Garage Fire Protection Framing 7. Slab; Steel -Wrapped 51. Property Line Firewall & Openings 8. Piers -Fireplace Ftg.-Steel 52. Ext. Doors -One 3' -Check Garage -3rd story, 2 exits 9. D.W.V.; Fall -Fittings -Test -2 way C/O -Sewer Test 53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 10. Gas Pipe; Size -Anchors 54. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 11. Water Pipe; Test -Anchors -Regulator -Service Test 55. Siding -Nailing Veneer 12. Electric; Underground 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 13. Plenums & Ducts; Clearance-Material-Supprt-Ins. 57. Glazing Area -Glass Protection -Skylights -Plastic 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 58. Shear Walls; Nailing -Bolts 15. Insulation 59. Insulation-Walls-Clg. 60. Infiltration-Walls-Wndws Card -81 Date Card -81 Date Card -131 Date Card -B1 Date Card -B1 Date Card -B1 Date Card -131 Date Card -81 Date Date PLUMBING (Permit) OK except #'s 16. Water Ht. Vent -Access -Combustion Air- Baffle Date FINAL (Plans) OK except #'s 17. Water Pipe; Test & Anchors -Nail Protection 61. Ext. Steps -Door & Sidelight Protection -Landings 18. D.W.V.; Test-Fttngs & Anchors -Nail Protection 62. Smoke Detector 19. Shower Pan; Test, First Floor -Tub Access 63. Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor -Ducts -Mach. Protection 20. Test Tub & Shower, 2nd Floor -Tub Access 21. Gas Pipe; Size & Anchors 64. Bedroom Exiting 65. G.F.I. & Bath Fixtures & Tub Access -Spa 66. Elec. Trim & Subpanel; Breaker Sizes -Labels Card -131 Date Card -131 Date 67. Stairs &Rails Card -B1 Date Card -131 Date 68. Fireplace or Stove; Clearances -Hearth Date ELECTRICAL (Permit) OK except #'s 69. Elec. Outlets at Wood Panel; Int. & Ext. 22. Fixture & Transformer Clearance -Ins. Protection 70. Kit. Fixt. & Appliance; Grnd. -Air Gap -Cooking Clearance 23. Elec. Receptacles Spacing -Lights & Switches at Doors 71. Elec. Outlets & Receptacles at Kit. Counter 24. Size Boxes & No. of Conductors -Stapled 72. Garage Fire Door; Swing -Landing -Closer 25. Romex Installed Close to Edge of Studs & C.J. 73. A.C. Duct in Garage -Damper 26. Equip. Ground made up w/Mech. Fasteners Bond Gas &Water 74. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 27. 2 Appliance Circuts in Kitchen & Conductor Size/G.F.I. 75, Plb., Elec. & Mech. Equip. Listed for Location 28. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / /ga. Cu or Al 76. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al. Insulated Neutral Yes No 77. Insulation -Foam -Looked in Attic ❑ Yes 78. Guard Rails & Deck Construction -Post Caps 30. Service -Riser Conductors & Ground -Main Disconnect 99. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 31. Equip. Clearances Panels-Motors-Mech. Equip. 80. Following instld.; Drive -0Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑ Yes ❑ No 32. Clothes Closet Light -Shower Light -Spa Light 33. Smoke Detector 8f, Stucco; Brown -Finish Card -131 Date Card -131 Date 82. A.C. Unit; Disconnect, Electrical, Plumbing Card -B1 Date Card -B1 Date 83. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Openings. Date MECHANICAL (Permit) OK except #'s 84. Water Well; Disconnect, Electrical, Plumbing 34. A.C. Ducts Insulation & Support 85. Exterior Elec. Trim; G.F.I. Receptacle -Underground 35. Vent Fan; Exhaust above insulation 86. Ventilation throughout House 36. Condensate Drain & Overflow; Size & Grade 87. Glass Protection 37. Furnace -Vent; Access -Comb. Air -Return Air Vent -115 outlet 88. Corrections from Previous Inpections 38. Attic Access & Platform if Furnace in Attic 89. Gas Test -Meters Tagged; Gas -Electric 90. Water & Sewer Connected -C/O to Grade -HD Approval 91. Energy Compliance Certificate -Other Certificates Card -131 Date Card -B1 Date 92. Roofing Certificate Card -B1 Date Card -81 Date Card -B1 Date Card -131 Date Card -B1 Date Card -131 Date Date FRAMING (Plans) OK except #'s 39. Sills, Proper Material & Anchors Card -B1 Date Card -B1 Date 40. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound Comments at Final: 41• Bearing Walls over Girders & Floor Nailing 42. Draft Stop in Walls (rat proof) 43. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 44. Header & Beam -Size & Bearing (NOTE: An entry must be made each time you visit job site) _ COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT P RMIT NO. �w ASSESS�ARCEL_ NUMBER ZONING ,, BUILDING PERMIT OWNER c 01 T HONE c SO. FT. OCC. BUILDING VALUATIGN '� OWNER'SMAILING ADDRESS r �J r CONTR OR'S NAME Clrw "ZF_1 TELEPHONE - ELEPHONECON7RAC7OFF'S CONTRACT OF~;LINZrA=RESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ LENDER'S MAILING ADDRESS Filing Fee $ 1000 Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ - Penalty $ BUILDING ADDRESS Permit fee $ 7S PLUMBING PERMIT Filing Fee 10.00 Each Trap 2,00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5,00 USE OF STRUCTURE /7 SF Duplex❑ Mob ilehome❑ Other --- ��'�C���, SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G I W 0.00 ea TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Othpl�❑ Describe work: C:4�`JL%FIC-7- , l4 X0 Penult Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 1100 AMP OR00V OR LESS10.00 Main service EA. ADD'L 100 AMP 2.50 U CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification �as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors.(Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING OCJr. , OR ADDNS. ACC. BLDGS. /2Osq ft NEW CONSTR U 1-OUTL NON.RESID BRA CH CIRCUITS2.50ea /POWER APPARATUS e (SINGLE OUTLET CIR. ) Ex. Occup(OUTLETS OR FIXTURES 2ALO 30 eLa Ex. Occup. OUT ETS P(RESID )REA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring g 15.00 Permit Fee $ WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): 17 The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling g Hood 3.00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. 1 also to save, indemnify and keep harmless the County of Butte against all bil' les judgments, costs, and expenses which may in any way accrue ag ins aid cause uence o e granting of this ermlt. %� Date— �a ignature of Applicant — Owner (/( Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ TOTAL PE MIT FEE $ gcuP.1 CONST.T P[ ISCN 00 , / V IFLOODIPARCEL -^ _ PD ND 59UE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECTOR OF PUBLIC By v PE T EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date —7 ���� Receipt No. &16- WNIT[-D.P.W.. •CLLO W-ASeCSSO R, PINK -IN BPCCTOR, GOLD CN ROD -APPLICANT COUNTY OF BUTTE - DEPARTMENfT'OF PUBLIC WORKS - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE: 916/538-7541 PERMIT APPLICATION DATA SHEET Permit No.� OWNER✓1/1 iiTd'�S A. 4V Date Proposed Building Use-' s Building Inspector "t✓' Dates At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED APPROVED 1. All items have been submitted . .................................... 2. Plot plans in duplicate/triplicate, signed by preparer of plans........ 3. Complete plans in duplicate/triplicate, signed by preparer of plans .. 4. Complete engineered plans and calcs, with wet signature on plans .. 5. Energy Design Compliance and supporting documentation ......... 6. Statement of Intent for Non -Heated and AC Buildings .............. 7. Engineered truss details and layout in duplicate (required prior to plan check) 8. Mobilehome installation data including manufacturer's installation instructions....................................................... 9. Fees of $ .......................... 10. Chico Urban Area fees paid ........................................ 11. Park fees paid ................................ ..................... deal=/u;G c= a School District fees paid ................. 6 30 13. Sanitation approval from Health Department ... 14. City of Chico plumbing. permit ...................................... 15. Plot plan and business license approval from City of (see City for other requirements) 16. PI nning approval for (A) Use: (B) Parking: ......... 17. provements may be required. Driveway permit (construction approvyal required prior to occupancy) ... Pre-Inspec. request to Pre -Inspection foroU4051224 required ...... Building Inspector 20. Contractor's license information (No., Name Style, Classification) ....... 21. Certificate of Workmans Compensation Insurance .................... 22. Owner -Builder Verification (Given to owner ❑, Mail to owner ❑) ........ 23. Recorded copy of Agricultural Acknowledgment Statement ............ 24. Letter of signature authorization ..................................... 25. 26. When you issue the permit, process as follows: Mail to owner. Mail to contractor. Telephoneand hold for pickup at office. Deliver w/inspector. Other Applicant �.. Date. ^lizN' Copy of plans sent Health Dept., Fire Dept., Other Date The following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data by_phone---nail—counter by date Contractor, designer, owner, was advised of above required data by—phone —mal l—counter by date Plans checked by Date Plans approved by_Date Sets of plans on hold in File cabinet AP folder Copy—DPW ate) COUNTY OF BUTTE.- Depar.tment.of_ Public Works 7 County Center Drive, Oroville, CA 95965. Phone: `916-538-7541 OWNER-BUILDER.VERIFICATION Attention Property Owner: _. An "owner -builder" building permit. has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in.processing and issuing your building permit. No building permit will be issued. until .this verification is received. I personally plan to provide the maj.or labor and materials..for.constructio.n of the proposed property improvement (yes or no) /+ 2. I (have/have not) /74kt e_ signed an application for a building permit . for the proposed work. 3: I have contracted with the following person (firm) to provide the proposed construction: Name Address City Phone Contractors.License No. 4. ,I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work: Name Address City Phone Contractors License No. 5. I will provide some of the work but I have.contracted (hired) the following persons to provide the work indicated Name Address Phone Type of Work Signed: Property Owner Social Securi ZNumbers Date NOTE: This Owner -Builder Verification is sent to you as required by Sections 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are per- mitted to issue the permit. BUTTE COUNTY SCHOOLS DEVELOPMENT FEE CERTIFICATION FORM (One Form per Building) A. P. Number 36--d,'-):) " Building Department No. School District('Je(jjrx4C ,��,�.. City D County ® Jurisdiction A Property Owner jy NAJ10"�4A) v Project Location /AddresZ16i2R Subdivision Lot Number Residential Development: lila Sq. Footage S05 #•of Living MHI Addition (Group R) Units Commercial/Industrial: D Sq. Footage New Addition (Including Exterior Roofed Areas) `Building Department,(/,Kepres'entative � Date (Floor Plans reviewed by School District Personnel), District Id -No. 17? School District certifies that (Applicant Name) (Phone Number) (Street Address) (City) (State) (Zip Code) has complied with the requirements of Resolution No. A'/„ 49-1 2-' by the payment of $ � representing A)h� square feet. ��L C,-, . School District Repre_sientative Date PAID BY CHECK NO. BANK NO PAID BY CASH REMARKS:, white -applicant; yellow -building department,,pink-school district SCHOOL.FEE (8/88) V FORM 7 ADDITIONS TO RESIDENTIAL BUILDINGS ENERGY SHEET PACKAGE "A" (Additions) OwnerClimate Zone Permit # Floor Area The following data showing mandatory and required features of Package "A" shall be installed for additions to dwellings. Additions to dwellings include room additions, -converting garages and patios to -living areas, house moves that add footage and attic conversions, and any space that is existing non -conditioned space that is converted to conditioned space. Remodeling 6f existing conditioned space is not included. ZONE 11 YR APPLIES TO NEW AREA CEILING R-30 WALL R-11 FLOOR R-11. SLAB R-7 GLAZING U-.65 (Dual) Dual,) SHADING SOUTH - OPTIMUM OVERHANG or .36 Shading Coefficient WEST - .36 Shading Coef f i:cient LOOSE FILL INSULATION (Density) INFILTRATION CONTROL (Weatherstrip doors, -certified windows, caulking) VAPOR BARRIER (Zone 16). DUCTS PER UNIFORM MECHANICAL CODE - Ch. 10 LIGHTING KITCHEN & BATH NOT LESS THAN 25.LUMENS/WATT- ® MAXIMUM GLAZING 16% OF -AREA PLUS REMOVED GLAZING NEW HEATING, VENTILATING,. AIR CONDITIONING AND HOT WATER SYSTEMS.IN CONJUNCTION WITH AN ADDITION SHALL BE INSTALLED AS SHOWN ON'BACK OF THIS SHEET. OTHER 12/85 *1 HEATING, VENTIIATING, AIR CONDITIONING SYSTEM (A) Heating ❑ Central Gas Furnace- % (brand and model number) SE � Btu/hr (heating capacity) ❑ Heat Pump (brand and model number) ACOP Btu/hr (heating capacity at 47°F) ❑ Active Solar type (liquid or air) Collector brand and ft2 model number solar fraction collector area collector orientation collector tilt rated y -intercept 07 I* so ❑ *2 rated slope .Other (describe) (B) Cooling Electric Air Conditioner (brand and model number) Btu/hr (cooling capacity at 95°F) Electric Heat Pump Btu/hr (cooling capacity at 95°F) Other (describe) (seasonal EER) EER DOMESTIC WATER SYSTEM (A) Gas Only Gallons (brand and model number) (tank size) Heat Pump w/Electric Backup (brand and model number) Gallons (tank size) Active Solar (collector brand and model number) (rated y -intercept) (rated slope)- (solar fraction) ft2 (backup heater type, brand and model number) (collector area) (collector orientation) (collector tilt) Location of Solar Panels Other (Describe) ' i *1 Submit documentation of sizing heating and cooling equipment by Manual J, sizing charts (form X64) or other approved methods, section 2-5352(g), and fill out the following: _ Heating: Winter design temperature °, elevation ', heating load BTU elevation factor x heating load = maximum outlet capacity gas furnace BTU Cooling: Summer design temperature ', cooling load BTU *2 Submit T.I.P,S.E. chart'or other approved system (form #5) to document sizing of solar panels. ® DESIGN COMPLIANCE STATEMENT: The above building design meets the requirements of Title 24, Part 2, Chapter 2-53 of the Califor Administration Code. IGNAT OF BUILDING DESIOER OR APPLICANT