HomeMy WebLinkAbout079-240-007r
JACKSON, TED,. RUTIi4 BILL' ,
6065 UPPER ;PALERMO RD. OROVILLE O�L� y a( -oO?
CONT; LARRY WEST `
ADD BEDROOM/SFS^
007
rY�
i
RtSIDENTIAL
036-280-054 94-1205B,E
" JACKSON, TED, RUTH & BILL'
6065 UPPER PALERMO RD., OROVILLE
CONT; LARRY WEST
ADD BEDROOM/ SF - 12-9)
i
JOB FINALED
Signature
r
V= OK
O = Not OK '
NotReaayab1e MOBILE HOMES
Date/Initials MOBILE HOME UTILITIES (Plans) OK except #'a
1. Zoning Requirements -Setbacks -Easements
2. Soils; Special MH Support Sketch
3. Sewer; Location -Test -Fall -C/O Concrete
4. Water; Location -Teat -Easement Needed (Sketch)
5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete
6. Gas; Location-Teat=Wrap: / /" L"ft.
/ /"Net. or/ /" L"ft./ /"LPG
7. Well Clearance & Disconnect
8. Utility Clearance
Date/Initials MOBILE HOME INSTALLATION (Plans) OK except #'s
1. Zoning Requirements -Setbacks Easements
2. Footings; Size -Spacing -Marriage Line =
3.. Gas; MH Teat -Demand -Valve -Connector
4. Electricity; MH Test -Crossovers -Breakers -Clearances
S. Drain; MH Test -Fall -Flex Connector
6. Water; MH Teat -Regulator -Connector
7. Water and Sewer Connected -C/O to Grade -HD Approval
8. Gas and Electricity Tagged
9. Exits; Insp.-Sketch
10. Cert. of Occupancy
MISCELLANEOUS
Date/Initial DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'a
1. Zoning Requirements -Setbacks -Easements
2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel
3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails
4. Wood Awn.; Posta-Beams-Rftrs -Connectors
Shthg.-Rfg.-Bracing
5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures
6. Carports; Windows -Doors
7. Electric
8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses
9. Siding; Nailing -Veneer -Stucco -Mesh
10. Roof; Shthg-Roofing
11. Ext.; Steps -Doors -Landings
Date/Initials POOLS (Plans) OK except #'s
1. Setbacks -Easements
2. Soils; Compaction -Structure Stability
3. Pool Structure; Steel -Connections -Thickness
Dead Men -Lining
4. Elec.; Receptacles and Lighting, Distances-GFI
5. Elec.; Pool Lighting; 15 volts-GFI
6. Elec.;Enclosures; Conduit Entries -Terminals -Listed
7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater.
8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg.
Boxes-Enclosures-Panelboards-Ina. to Main in Conduit
9. Health Department Approval
10. Plumb.; Cir. Test -Water Supply Test
V=OK
O = Not OK
- = Not Applicable
= Not Ready
OK except #'s
RESIDENTIAL (Single & Duplex)
2. Ftg., Main; Soils-Elec. Grnd.- tg. Depth
1 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth
4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth
5. Stemwalls, Main; Steel-Blockouts-Wrapped
6. Stemwalls, Garage; Steel-Blockouts-Wrapped
6a. Hold Downs and Special Anchors
7. Slab; Steel -Wrapped
8. Piers -Fireplace Ftg.-Steel
9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test
10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test
11. Water Pipe; Test -Anchor -Regulator -Service Test
12. Electric; Underground
13. Plenums & Ducts; Clearance -Materiel -Support -Ins.
14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples
15. Access & Ventilation
16. Insulation
Date/Initialr6.
MBINO Permit OK except #'s
Water Htr.; Vent -Access -Combustion Air -Baffle
Water Pipe; Test & Anchor -Nail Protection
.W.V.; Test -Fittings & Anchor-Naii Protection
hower Pan; Test, First Floor -Tub Access
20. Test Tub & Shower, Second Floor -Tub Access
21. Gas Pipe; Size & Anchors
OK except #'s
9f .. Fjxt"ure & Transformer Clearance -Ins. Protection
& Switches at Doors
Size oxes & No. of Conductors -Stapled
ex Installed Close to Edge of Studs & C.J.
JW. ground made up w/Mach. Fastners-Bond Gas & Water
27. 2 AppRaace Circuts in Kitchen & Conductor Size/GFI
ubfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga.
Cu or Al
ange Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al.
lnsu1jW Neutral ❑ Yes ❑ No
e ** a- iser Conductors & Ground -Main Disconnect
3j/qW1p-.,Clearances Panels -Motors -Mach. Equip.
a21,914mes Closet Light -Shower Light -Spa Light
Smoke Detector
Date/Initials MECHANICAL (Permit) OK except #'s
34. A.C. Ducts Insulation & Support
35. Vent Fan; Exhaust above insulation
36. Condensate Drain & Overflow; Size & Grade
37. Furnance-Vent; Access -Comb. Air -Return Air Vent -115 outlet
38. Attic Access & Platform if Furnance in Attic
s) OK except #'s
Material & Anchors
4*.1'BQring Wells over Girders & Floor Nailing
4Z/D,!�ft,Stop in Walls (rat proof)
4,4/Fyf'Stops; Furred Ceilings -Stairs -Chases -Tub
44. Headers & Beam -Size & Bearina
Date/Initials FRAMING (Continued)
49. Ft -Post Caps -Anchors -Connectors
46 Ong. Joist-Rftr. ties -Pu rlin-roof Brac-Truss-Shthng.-Rfng.
ace Ties or Type A Flue -Fireplace Throat clearance
A 'c Access; Size & Romex Protection -Draft Stop -Ins. Baffles
49-Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions
'S6"13�ge Fire Protection Framing
5`1-. ropAY-Line Firewall & Openings
Wit. Do rs-One 3' -Check Garage -3rd Story, 2 Exits
. tai ; Width -Headroom -Rise -Run -Landing -Fire Protection
64-'plywc6d on Roof Overhang -Attic Vents -Rafter Outriggers
Siding -Nailing Veneer
. o o Mesh -Drip Screed -Fd. Vents-Underflr. Access
Gla_zing Area -Glass Protection -Skvliahts-Plastic
Y,ZVjW9. Insulation -Walls -Ceilings
'fI/ ` 60. Infiltration -Wells -Windows
Date/Initials FINAL lens OK except #'s
AO-txt. Steps -Door & Sidelight Protection -Landings
Detector
6T- Furnace; Vents -Clearance -Comb. Air-Connector-
Inssarege; Above Floor -Ducts -Mach. Protection
64 Be room Exiting
G.F.I.,& Bath Fixtures & Tub Access -Spa
lec. Trim & Subpanel; Breaker Sizes & Labels
�6, airs & Rails
68--F ce or Stove; Clearances -Hearth
fif'Elec. Outlets at Wood Panel; Int. & Ext.
�KiLFiXt & Appliance; Grnd: Air Gap -Cooking Clearance
-4+-Erec Outlets & Receptacles at Kit. Counter
_22 -Garage Fire Door; Swing -Landing -Closer
-31C." uct in Garage -Damper
r74- Wtr-otr.; Vents -Clearance -Comb. Air-Connector-P.R.V.
1 arage; Above Floor -Mach. Protection
Plb., Elec. & Mach. Equip. Listed for Location
eceptacles in Garage; (G.F.I.)-Romex Protection
Insulation -Foam -Looked in Attic ❑ Yes
Rails & Deck Construction -Post Caps
-?9--Fdn: Gents & Crawl Hole Door -Drainage & Wood -Earth
Clearance Looked under Floor ❑ Yes
80. Following inist O, Drive Yes ❑ No; Walks es ❑ No;
Planters VJ'Yes ❑ No
Na4--6tneeo,' Brown -Finish
Unit; Disconnect, Electrical, Plumbing
Aal-Vents Above Roof; Plbg: Appliance -Fireplace. -Clearance to
44.-Wgter Well; Disconnect, Electrical, Plumbing
Sff-'_Ex rlor Elec. Trim; G.F.I. Receptacle -Underground
Vegj,LW-on Throughout House
8 . I 5 Protection
Corrections from Previous Inspections
8 . gas Test -Meters Tagged; Gas -Electric
9 . titer & Sewer Connected -C/O to Grade -HD Approval
Of Energy compliance Certificate -Other Certificates
Comments at Final:
COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION
7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 P� MIT NO.
APPLICATION AND PERMIT �� OS
(
ASSESSOR PARCEL NUMBER
036-280-094
ZONING
ARMH25
BUILDING PERMIT
OWNER
TED, RUTH -9 'RIT.T. JACKSON
TELEPHONE
SQ. FT. OCC. BUILDING VALUATION
340 R 18 360.00
OWNER'S MAILING ADDRESS
6065 UPPER PATERMID RT) OROVILLF, 99966
CONTRACTOR'S NAME
LARRY WEST
TELEPHONE
19*11-5478
CONTRACTOR'S MAILING ADDRESS
Fireplace
CONSTRUCTION LENDER
UNKN WN
Total Valuation $
LENDER'S MAILING ADDRESS
Filing Fee $ 20.00
Permit Fee $ 198.00
ARCHITECT OR ENGINEER
LICENSE NO.
Plan Checking Fee $
Energy Plan Checking Fee $ 23.00
ARCHITECT OR ENGINEER'S MAILING ADDRESS
Penalty $
BUILDING ADDRESS 6065 UPPER PALERMO RD
PERMIT FEE $ 369 70
OROVILLE, 95965
PLUMBING PERMIT Filing Fee 20.00
Each Trap 7.00
Solar or heat pump water heater 23.00
Water piping 15,00
LOT NO.
SUBDIVISION'S NAME
PARCEL MAP
Each gas water heater or vent 15.00
USE OF STRUCTURE
SF IS Duplex O Mobilehome ❑ Other
SPECIFY
Gas piping system 1 - 5 outlets 15.00
Building sewer 15.00
Mobile Home S G W @20.00
TYPE OF WORK
New ❑ Addition CK Remodel O Utilities O Installation O Other ❑
Describe Work: 17 X 20
PERMIT FEE $
Contractor
ELECTRICAL PERMIT Filing Fee 20.00
BEDROOM
11V OR LESS
Main Service ( OOAORLESS ) 23.00
Main Service ( 200A To IOOOA 46.00
NEW CONST. DWELLING OCCUP.
OR ADONS. ( 8 ACC. BLDS. 1 3.50 FT,$0.
CONTRACTORS LICENSE LAW(
I declare under penalty of perjury (check one)
1 am a licensed under provisions of Chapter 9, Division 3 of the Business and
Professions C de and license is in full for and effect.
y any s
License No. (pZ�fBl / Classification .(�
O I, as the owner, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec 7044)
O I, as the owner, am exclusively contracting with licensed contractors. (Sec 7044)
O 1 am exempt under Sec. Business and Professions Code
forthis reason
NEW CONST. MULTI -OUTLET
-NON-RESID. ( BRANCH CIRCUITS I 7.50
POWERAPPARATUS '
& SINGLE OUTLET CIR.
Ex. Occup. ( OUTLET OR FIXTURES 1 BAL. @ (.50
Ex. Occu FIXED APPLNS. OR
p' ( OUTLETS (RESID.) EA. ) 5.00
Temporary Service 23.00
Mobile Home Facilities 20.00
Misc. Wiring 23.00
WORKER'S COMPENSATION INSURANCE
1 declare under penalty of perjury (check one):
O This permit is for $100.00 (valuation) or less.
O 1 have placed on file with the County of Butte Dept. of Development Services,
Building Division a Certificate of Workmen's Compensation Insurance or a
Certificate of Consent to Self -insure.
I shall not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California.
Notice to Applicant: If after making this statement, should you become subject to the
Worker's Compensation provisions of the Labor Code, you must forthwith comply with
such provisions or this permit will be revoked.
PERMIT FEE s 31.90
Contractor
MECHANICAL PERMIT Filing Fee 20.00
Heating
Cooling
Hood 6.50
Ventilation
PERMIT FEE $
Contractor
I certify that I have read this application and state that the above information is correct.
I agree to comply to all Butte County Ordinances and California State Laws relating to
building construction, and hereby authorize representatives of the County of Butte to
enter upon the above mentioned property for inspection purposes.
I also agree to save, indemnify and keep harmless the County of Butte against all
liabilities, jgments, costs, and expenses which may in any way accrue against said
seque a of 'e granting of this permit. /� pp
County4ref
X Date 7— 2S— 6 �
Sign Aplicant Owner Contractor O Agent
An OSHA pe it is required for excavations over 5"0" deep and demolition or
construction f structures over 3 stories in height.
Mobile Home Installation Fee $
Energy Inspection Fee $ 46.00
c0N T. TOTAL FE
HAZ D. FE IMP I Ftp CDF I PARCEL PD ND ISS
This permit is hereby issued under the applicable provisions
of the Butte County Code and/or Resolutions to do work
indicated above for which fees have been paid.
STE-D.D.S.-B.D.
PERMIT EXPIRES ON
Me rel
eiptNo. 162623 - 447.60
E
CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT
—
.COUNTYOF BUTTE - DErARWMENTOF DEVBL0'PMENTSERVICES -BUILDING DIVISION
7COUNTY CENTER^DRI OROVILLE, CALIFORNIA95965 -TELEPHONE (916)538-7-1,41
PERMIT APPLICATION DATA SHEET
OWNER Jo-i5k So n r A. P. No.
Proposed Building Use Building Inspector Date
At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance:
DATE RECEIVED BY
1. All items have been submitted.........................................
2. Plot plans, 3/4 sets, signed by preparer of plans . ..........................
3_ Complete plans, 3/4 sets, signed by preparer of plans . ......................
.4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . .............
5. Hazardous Material Form. .......... ................................... .
6. Energy Design Compliance and supporting documentation . ..................
7. Statement of Intent for Non -Heated and A/C Buildings . ......................
8. Engineered truss details and layout in duplicate (required prior to plan check). ....
9. Mobilehome data and manufacturer's installation instructions, 2 sets. ...........
10. Fees of $
11. Impact fees as shown on attached schedule.
-- 12. California Department of Forestry plan approv/f es. 3'
13. Flood elevation letter (100 year flo . ) by C Fforni gineer. . .
14. Sanitation and plot plan approval rOv( f- Health Department . ........... .
15. City of Chico plumbing permit . ......................................... .
16. Plot plan and business license approval from City of Biggs/Gridley. . ..........
17. Planning approval for (A) Use: (B) Parking: . ........
18. Contact Land Development.about (A) Improvements (B) Drainage. ....... .
19. Driveway permit (construction approval required prior to occupancy). .. . .
20. Pre -inspection for to Building
Ins re for
required. . . to Building Inepedor (Date)
21. Contractor's license information. (No., Name Style, Classification) . ..............
22. Certificate of Workmans Compensation Insurance . ..........................
23. Owner -Builder Verification (Given to owner , Mail to owner _). ...........
24. Recorded copy of Agricultural Acknowledgement Statement . ..................
25. Letter of signature authorization . ........................................ +
26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .... .
27. Letter of intent on building use . ......................................... T
28. Mobilehome utility clearance . ...........................................
29. Documentation of legal access . ..................... :..................
30. Documentation of 50% subdivision developed or (A) Road improvements completed
and (B) Parcel meets zoning area and frontage requirements . ...............
31. Existing violations/expired permits . ......................................
32. Plan check list . .....................................................
33
34.
Wh;ryou issue the permit, process as follows: Mail to .. ner. Mail to contractor.
x Telephone and hold forpickup atno 1,P office. Deliver with inspector.
Other
Parcel Creation
Acreage Applicant Date O 7 7
Copy of Haz=Mat form sent Health Dept. Fire Dept. lair Pollution Date
Copy of plans sent Health Dept. Fire Dept. Other Date By
The following data must be submitted prior to permit issuance: (Circle new item not checked above).
1. Index permit for above items No.
2. Additional items required:
Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date
Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date
Plans checked by Date Plans approved by Date
Sets of plans on hold in File cabinet AP folder
- Copy - Department of Public Works
NLY
F_II. USE I/
.�J Plot Plan Aaached
Floor Plan Ana ed
Scnt to D.D. �-
TO: Building Department
FROM: Environmental Health
SUBJECT: Sanitation Clearance
ac S gky-m Rd
Owner Loca ion j AP// /
Plan Approved for:
Hold final for:
Final clearance O.K. for:
Sewage Disposal Water Supply
Water Supply
9 %
Water Supply
me. Other ¢ h ✓'-�, G l � 1/yx�— T�
Clearance for bedroom mobile h
NOTE:
Environmental Health Specialist
Date
BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM
(One Form Per Building)
School District �r o v Ile- U n r e) 4 Building Department No.
A.P. Number (23 'J WOSI-
Jurisdiction . 0 City 1XI County
Proper
Proper
Subdiv
Residential Development
Commercial/Industrial
0 0
No. of Living. MHI
Units
New
Sq. Footage
A d ion (Group R)
0
Addition
Identification
(Floor Plans reviewed by School District Personnel)
111q
C. ch 01'61'st ict certifies that
Sq. Footage
(Including Exterior
Roofed Areas)
a �
Date
plicant)
(Sss) ;. U. p .. (� (Phone Number)
(City) (State)
has complied with the requirements of Resolution No. �Q z
representing 13 ."TO square feet.
School District Representative
Paid by Check Number Remarks
Bank Number
Paid by Cash
(Zip Code)
by payment of $
-�--as=s
Date
O
NE
If, subsequent to the School District Representative signing this Butte County Schools Impact Fee
Certification Form, the School District is notified by the applicable Local Planning Agency that this project
is being reviewed under the California Environmental Quality Act (CEQA), this.project may be subject to
additional school fees to fully mitigate its impact on the school district's schools.
White (applicant), Yellow (building department), Pink (school district) feeformmkl (4/92)
TABLE OF CONTENTS TOC
Project Title.......... Addition for Jackson Date........ 05/03/94
1 d
Project Address........ 6065 Upper Pa ermo R .
Oroville CA
Documentation Author... Neal Kuopus
Company ................ CALCTECH
Telephone .............. (916) 589-4219
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 11
Field Check/ Date
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -TOC
User#-MP1320 User-CALCTECH Run -Existing + Addition
TABLE OF CONTENTS
.Report Page
FORM CF -1R ................ 1
FORM MF -1R................ 4
FORM C -2R ................. 6
FORM C -3R ................. 9
HVAC SIZING ............... 14
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R
Project Title.......... Addition for Jackson Date........ 05/03/94
d
Project Address........ 6065 r UppePalermo R .
Oroville CA
Documentation Author... Neal Kuopus
Company ................ CALCTECH
Telephone .............. (916) 589-4219
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 11
Field Check/ Date
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -FORM CF -1R
User#-MP1320 User-CALCTECH Run -Existing + Addition
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Stories..........
Floor Construction Type....
Component
Type
Wall
Door
Floor
Roof
Wall
S1abEdge
Wall
Orientation
1108 sf
Single Family Detached
Existing Plus Addition
Front Facing 0 deg (N)
1
1
Raised Floor (Package E)
BUILDING SHELL INSULATION
Insulation Assembly
R -value U -Value Location/Comments
R-0
0.306
R-0
0.330
R-0
0.097
R-19
0.047
R-13
0.083
R-0
0.900
R-13
0.090
# of Interior
Area U- Pan- Shading/
(sf) Value es Description
FRONT, RIGHT, BACK, LEFT
FRONT ENTRY, ADDITION
TO CRAWLSPACE
FLAT CEILING, ADDITION
ADDITION
ADDITION
ADDITION
FENESTRATION
Over -
Exterior hang/ Framing
Shading Fins Type
Window
Front
(N)
26.3
1.190
1
Drapes.Std
None
Yes
Metal
Window
Right
(W)
36.0
1.190
1
Drapes.Std
None
None
Metal
Window
Back
(S)
32.3
1.190
1
Drapes.Std
None
Yes
Metal
Window
Left
(E)
0`10.0
1.190
1
Drapes.Std
None
None
Metal
Window
Front
(N)
-12.0
0.750
2
Drapes.Std
None
Yes
Metal
Window
Back
(S)
10.0
0.750
2
Drapes.Std
None
Yes
Metal
Window
Left
(E)
-10.0
0.750
2
Drapes.Std
None
None
Metal
Skylight
Horz
4.0
0.800
2
None
None
None
Metal
THERMAL MASS
Area Thickness
Type
Exposed
(sf) (in)
Location/Comments
S1abOnGrade
Yes
340 3.5
Exposed
at Addition
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -FORM CF-lR
User#-MP1320 User-CALCTECH Run -Existing + Addition
HVAC SYSTEMS
R-2.1 existing duct insulation
R-0 existing floor insulation per Form 3
R-0 existing wall insulation per'Form 3s
R-13 wall insulation required at Addition per Form 3s
R-19 existing ceiling insulation per Form 3
R-19 ceiling insulation required at Addition per Form 3
Opaque U -values per CEC TABLE 7-2 for pre -1978 construction
Glazing U -values per CEC TABLE 7-2 for pre -1978 construction
Glazing U -values per MFR'S. NFRC testing & certification at Addn.
Viking metal frame dual -pane clear glazing reqd. at Addition
E.FURN.75: per CEC TABLE 7-2 for pre -1978 construction
E.AC.8.0: CEC MIN. REQUIREMENT
HWH: NOT ALTERED - NO CALCULATIONS
Minimum
Duct
Duct
Thermostat
Equipment Type
Efficiency
Location
R -value
Type
Furnace
0.750 AFUE
Attic
R-2.1
NoSetback
ACSplit
8.00 SEER
Attic
R-2.1
NoSetback
SPECIAL
FEATURES/REMARKS
R-2.1 existing duct insulation
R-0 existing floor insulation per Form 3
R-0 existing wall insulation per'Form 3s
R-13 wall insulation required at Addition per Form 3s
R-19 existing ceiling insulation per Form 3
R-19 ceiling insulation required at Addition per Form 3
Opaque U -values per CEC TABLE 7-2 for pre -1978 construction
Glazing U -values per CEC TABLE 7-2 for pre -1978 construction
Glazing U -values per MFR'S. NFRC testing & certification at Addn.
Viking metal frame dual -pane clear glazing reqd. at Addition
E.FURN.75: per CEC TABLE 7-2 for pre -1978 construction
E.AC.8.0: CEC MIN. REQUIREMENT
HWH: NOT ALTERED - NO CALCULATIONS
CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -FORM CF -1R
User#-MP1320 User-CALCTECH Run -Existing + Addition
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title -24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility. When this certificate of compliance is
submitted for a single building plan to be built in multiple orientations,
any shading feature that is varied is indicated in the Special Features/
Remarks section.
DESIGNER or OWNER
Name.... Larry West
Company. Larry West Construction
Address. 2342 Via Laton
Oroville, CA 95966
Phone... (916) 533-5478
License.
Signed..
(date)
ENFORCEMENT AGENCY
Name....
Title...
Agency..
Phone...
Signed..
(date)
DOCUMENTATION AUTHOR
Name.... Neal Kuopus
Company. CALCTECH
Address. Drawer G
Feather Falls, CA 95940
Phone... (916) 589-4219
Signed.. � S/13 q
(date)
MANDATORY MEASURES CHECKLIST:• RESIDENTIAL Page 4 MF -1R
Project Title.......... Addition for Jackson Date........ 05/03/94
Project Address........ 6065 Upper Palermo Rd.
Oroville CA
Documentation Author... Neal Kuopus
Company ................ CALCTECH
Telephone .............. (916) 589-4219
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 11
Building Permit
Plan Check Date
Field C edk Date
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -FORM MF -1R
User#-MP1320 User-CALCTECH Run -Existing + Addition
Lowrise residential buildings subject to the Standards must contain these
measures regardless of the compliance approach used. Items marked with an
asterisk (*) may be superseded by more stringent compliance requirements listed
on the Certificate of Compliance. When this checklist is incorporated into the
permit documents,. the features noted shall be considered by all parties as
binding minimum component performance specifications for the mandatory measures
whether they are shown elsewhere in the documents or on this checklist only.
BUILDING ENVELOPE MEASURES
Design- Enforce-
er ment
*150(a): Minimum R-19 ceiling insulation.
150(b): Loose fill insulation manufacturers labeled R -Value.
*150(c): Minimum R-13 wall insulation in framed walls
(does not apply to exterior mass walls).
*150(d): Minimum R-13 raised floor insulation in framed floors;
minimum R-8 in concrete raised floors.
150(1): Slab edge insulation - water absorption rate no greater
than 0.3%, water vapor transmission rate no greater than 2.0
perm/inch.
118: Insulation specified or installed meets CEC quality .
standards. Indicate type and form.
116-17: Fenestration Products, Exterior Doors and Infiltration/
exfiltration controls
a. Doors and windows between conditioned and unconditioned
spaces designed to limit air leakage.
b. Manufactured fenestration products have label with
certified U -value, and infiltration certification.
c. Exterior doors and windows weatherstripped; all joints
and penetrations caulked and sealed.
150(g): Vapor barriers mandatory in Climate Zones 14 and 16
only.
150(f): Special infiltration barrier installed to comply with
Sec. 151 meets CEC quality standards.
150(e): Installation of Fireplaces, Decorative Gas Appliances
and gas logs
1. Masonry and factory -built fireplaces have:
a. Closeable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
MANDATORY MEASURES CHECKLIST:- RESIDENTIAL Page 5 MF -1R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -FORM MF -1R
User#-MP1320 User-CALCTECH Run -Existing + Addition
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES
Design- Enforce-
er ment
110-13: HVAC equipment, water heaters, showerheads and faucets
certified by the CEC.
150(1): Setback thermostat on all applicable heating systems.
150(j): Pipe and Tank insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or
backup solar hot water tanks) have insulation blanket (R-12
or greater) or combined interior/exterior insulation (R-16
or greater).
2. First 5 feet of pipes closest to water heater tank, non -
recirculating systems, insulated (R-4 or greater).
3. All buried or exposed piping insulated in recirculating
sections of hot water system.
4. Cooling system piping below 55 degrees insulated.
5. Piping insulated between heating source and indirect
hot water tank.
*150(m): Ducts and Fans
1. Ducts constructed, installed and sealed to comply with UMC
sections 1002 and 1004; ducts insulated to a minimum
installed value of R-4.2 or ducts enclosed entirely within
conditioned space.
2. Exhaust fan systems have backdraft or automatic dampers.
3. Gravity ventilating systems serving conditioned space have
either automatic or readily accessible, manually
operated dampers.
114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off
switch, weatherproof operating instructions, no electric
resistance heating and no pilot light.
2. System installed with:
a. At least 36 inches pipe between filter and heater for
future solar heating.
b. Cover for outdoor pools or outdoor spa.
3. Pool system has directional inlets and a circulation.
pump time switch.
115: Gas-fired central furnace, pool heater, spa heater or
household cooking appliance have no continuously burning
pilot light (Exception: Non -electrical cooking appliance
with pilot < 150 Btu/hr.).
LIGHTING MEASURES
Design- Enforce-
er ment
150(k): 40 lumens/watt or greater for general lighting in
kitchens and rooms with water closets; and recessed ceiling
fixtures IC (insulation cover) approved.
COMPUTER METHOD SUMMARY Page 6 C -2R
Project Title.......... Addition for Jackson Date........ 05/03/94
Project Address........ 6065 Upper Palermo Rd.
Oroville CA
Documentation Author... Neal Kuopus
Company ................ CALCTECH
Telephone.............. (916) 589-4219
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 11 1
Field Check/ Date
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZllS92 Program -FORM C -2R
User#-MP1320 User-CALCTECH Run -Existing + Addition
MICROPAS4 ENERGY USE SUMMARY
Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating..........
15.12
40.97
-25.85
Space Cooling..........
15.89
34.43
-18.54
Total
31.01
75.40
-44.39
*** Water
Heating not
calculated ***
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type...............
Construction Type .........
,Building Front Orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Footprint Area .............
Ground Floor Area..........
Slab -On -Grade Area.........
Glazing Percentage.........
Average Ceiling Height.....
1108 sf
Single Family Detached
Existing Plus Addition
Front Facing 0 deg (N)
1
1
ReducedYear
Raised Floor
1
8864 cf
1108 sf
1108 sf
340 sf
12.7 % of FA
8 ft
BUILDING ZONE INFORMATION
(Package E)
Floor
# of
Vent
Special
Area
Volume Dwell Cond- Thermostat
Height
Vent Area
Zone Type (sf)
(cf) Units itioned Type
(ft)
(sf)
HOUSE
Residence 1108
8864 1.00 Yes NoSetback
2.0
n/a
COMPUTER METHOD SUMMARY Page 7 C -2R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -FORM C -2R
User#-MP1320 User-CALCTECH Run -Existing + Addition
OPAQUE SURFACES
Area
U-
Insul
Act
Solar
Form 3
Location/
Surface
(sf)
value
R-val
Azm Tilt Gains
Reference
Comments
HOUSE - Existing
1
Wall
210
0.306
R-0
0
90 Yes
R.0.2X4.24
FRONT
2
Door
20
0.330
R-0
0
90 Yes
None
FRONT ENTRY
3
Wall
156
0.306
R-0
270
90 Yes
R.0.2X4.24
RIGHT
4
Wall
224
0.306-R-0
180
90 Yes
R.0.2X4.24
BACK
5
Wall
46
0.306
R-0
90
90 Yes
R.0.2X4.24
LEFT
6
Floor
768
0.097
R-0
0
0 No
FC.0.2X6.16
TO CRAWLSPACE
7
Roof
768
0.047
R-19
0
0 Yes
R.19.2X4.24
FLAT CEILING
HOUSE - New
8
Wall
131
0.083
R-13
0
90 Yes-
MW.13.2X4.16
ADDITION
9
Door
17
0.330
R-0
0
90 Yes
None
ADDITION
10
Wall
130
0.083
R-13
180
90 Yes
MW.13.2X4.16
ADDITION
11
Door
20
0.330
R-0
180
90 Yes
None
ADDITION
12
Wall
126
0.083
R-13
90
90 Yes
MW.13.2X4-.16
ADDITION
14
Wall
12
0.090
R-13
0
90 Yes
AW.13.2X4.16
ADDITION
15
Roof
336
0.047
R-19
0
0 Yes
R.19.2X4.24
ADDITION
PERIMETER
LOSSES
Length
F2
Insul Solar
Surface
(ft)
Factor
R-val Gains
Location/Comments
HOUSE -
New
13 S1abEdge
57
0.900
R-0
No
ADDITION
FENESTRATION
SURFACES
# of
Vent
Sc
Sc Interior
Area
Pan-
Frame
Open .
U- Act
Glass
Int Shading/
Surface
(sf)
es
Type
Type
value Azm Tlt Only
Shade Description
HOUSE - Existing
1
Window
6.3
1
Metal
Slider
1.190 0
90 1.00
0.88 Drapes.Std
2
Window
10.0
1
Metal
Slider
1.190 0
90 1.00
0.88 Drapes.Std
3
Window
10.0
1
Metal
Slider
1.190 0
90 1.00
0.88 Drapes.Std
4
Window
36.0
1
Metal
Slider
1.190 270
90 1.00
0.88 Drapes.Std
5
Window
16.0
1
Metal
Slider
1.190 180
90 1.00
0.88 Drapes.Std
6
Window
6.3
1
Metal
Slider
1.190 180
90 1.00
0.88 Drapes.Std
7
Window
10.0
1
Metal
Slider
1.190 180.
90 1.00
0.88 Drapes.Std
8
Window
10.0
1
Metal
Slider
1.190 90
90 1.00
0.88 Drapes.Std
HOUSE - New
9
Window
12.0
2
Metal
Slider
0.750 0
90 0.88
0.78 Drapes.Std
10
Window
10.0
2
Metal
Slider
0.750 180
90 0.88
0.78 Drapes.Std
11
Window
10.0
2
Metal
Slider
0.750 90
90 0.88
0.78 Drapes.Std
12
Skylight
4.0
2
Metal
Fixed
0.800 0
0 0.88
0.88 None
COMPUTER METHOD SUMMARY Page 8 C -2R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZllS92 Program -FORM C -2R
User#-MP1320 User-CALCTECH Run -Existing + Addition
Area
Surface (sf)
HOUSE - Existing
1
Window
6.3
2
Window
10.0
3
Window
10.0
5
Window
16.0
6
Window
6.3
7
Window
10.0
HOUSE - New
9
Window
12.0
10
Window
10.0
Mass Type
Area Thick Heat Conduct- Surface
(sf) (in) Cap ivity R -value Location/Comments
HOUSE -Existing
1 S1abOnGrade 340
System Type
3.5 28.0 0.98 R-0.0 Exposed at Addition
HVAC SYSTEMS
Minimum Duct
Efficiency Location
HOUSE
Furnace 0.750 AFUE Attic
ACSplit 8.00 SEER Attic
SPECIAL FEATURES/REMARKS
Duct Duct
R -value Efficiency
R-2.1 0.780
R-2.1 0.740
R-2.1 existing duct insulation
R-0 existing floor insulation per Form 3
R-0 existing wall insulation per Form 3s
R-13 wall insulation required at Addition per Form 3s
R-19 existing ceiling insulation per Form 3
R-19 ceiling insulation required at Addition per Form 3
Opaque U -values per CEC TABLE 7-2 for pre -1978 construction
Glazing U -values per CEC TABLE 7-2 for pre -1978 construction
Glazing U -values per MFR'S. NFRC testing & certification at Addn.
Viking metal frame dual -pane clear glazing reqd. at Addition
E.FURN.75: per CEC TABLE 7-2 for pre -1978 construction
E.AC.8.0: CEC MIN. REQUIREMENT
HWH: NOT ALTERED - NO CALCULATIONS
OVERHANGS AND SIDE FINS
Window-
Overhang
Left Fin
Right
Fin -
Left
Rght
Hght
Wdth
Dpth
Hght
Ext
Ext
Ext
Dpth
Hght
Ext
Dpth
Hght
2.5
2.5
20
0.8.
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
4
2.5
20
0.8
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
4
2.5
1.3
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
4
4
1.3
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
2.5
2.5
1.3
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
4
2.5
1.3
1
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
4
3
2
0.7
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
5
2
2
0.7
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
THERMAL MASS
Area Thick Heat Conduct- Surface
(sf) (in) Cap ivity R -value Location/Comments
HOUSE -Existing
1 S1abOnGrade 340
System Type
3.5 28.0 0.98 R-0.0 Exposed at Addition
HVAC SYSTEMS
Minimum Duct
Efficiency Location
HOUSE
Furnace 0.750 AFUE Attic
ACSplit 8.00 SEER Attic
SPECIAL FEATURES/REMARKS
Duct Duct
R -value Efficiency
R-2.1 0.780
R-2.1 0.740
R-2.1 existing duct insulation
R-0 existing floor insulation per Form 3
R-0 existing wall insulation per Form 3s
R-13 wall insulation required at Addition per Form 3s
R-19 existing ceiling insulation per Form 3
R-19 ceiling insulation required at Addition per Form 3
Opaque U -values per CEC TABLE 7-2 for pre -1978 construction
Glazing U -values per CEC TABLE 7-2 for pre -1978 construction
Glazing U -values per MFR'S. NFRC testing & certification at Addn.
Viking metal frame dual -pane clear glazing reqd. at Addition
E.FURN.75: per CEC TABLE 7-2 for pre -1978 construction
E.AC.8.0: CEC MIN. REQUIREMENT
HWH: NOT ALTERED - NO CALCULATIONS
CONSTRUCTION ASSEMBLY Page 9 3R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -FORM 3R
User#-MP1320 User-CALCTECH Run -Existing + Addition
Reference Name ..R.0.2X4.24
Description . Roof R-0 2x4 24oc
Type ........... Roof
R -Value ........ 0 sf-F/Btuh
Framing •,
Material ..... FIR.2X4
Spacing ...... 24 inches on center
Fraction 0.07
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
SHNGL.ASPHLT
Asphault shingle roofing
0.44
0.44
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3.
PLY.0.50
0.50 in plywood
0.62
0.62
4.
AIR.RF.3.50
3.5 in & greater air space: heat flow up
0.80
0.80
5c.
RO.PLACEHOLD
R-0 PLACE HOLDER
0.00
--
5f.
FIR.2X4
2x4 in fir framing
--
3.46
6.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.RF
Inside air film: heat flow straight up
0.61
0.61
Total Unadjusted R -Values
3.15
6.61
FRAMING
ADJUSTMENT
CALCULATION
Cavity Framing Total
U -Value: (1 / 3.15.x 0.93) + (1 /, 6.61 x 0.07) = 0.306
Btuh/sf-F
Total
R -Value:
1 / 0.306 = 3.27
sf-F/Btuh
CONSTRUCTION ASSEMBLY Page 10 3R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -FORM 3R
User#-MP1320 User-CALCTECH Run -Existing + Addition
Reference Name . FC.0.2X6.16
Description .... Floor Crwl R-0 2x6 16oc
Type ........... Floor
R -Value ........ 0 sf-F/Btuh
Framing
Material ..... FIR.2X6
Spacing ...... 16 inches on center
Fraction ..... 0.10
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
CRAWLSPACE
Effective R -value of vented crawlspace
.6.00
6.00
2c.
RO.PLACEHOLD
R-0 PLACE HOLDER
0.00
--
2f.
FIR.2X6
2x6 in fir framing
--
5.45
3.
PLY.0.63
0.625 in plywood
0.77
0.77
4.
CARPET
Carpet & pad
2.08
2.08
I.
FILM.IN.FLR
Inside air film: heat flow down
0.92
0.92
Total Unadjusted R -Values
9.94
15.39
FRAMING
ADJUSTMENT
CALCULATION
Cavity Framing Total
U -Value:
(1 / 9.94 x 0.90).+ (1 / 15.39 x 0.10) = 0.097
Btuh/sf-F
Total
R -Value:
1 / 0.097 = 10.30
sf-F/Btuh
CONSTRUCTION ASSEMBLY Page 11 3R
Project Title..i........ Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -FORM 3R
User#-MP1320 User-CALCTECH Run -Existing + Addition
M
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Reference Name . R.19.2X4.24
Description .... Roof R-19 2x4 24oc
Type ........... Roof
R -Value ........ 19 sf-F/Btuh
Framing
Material ..... FIR.2X4
Spacing ...... 24 inches on center
Fraction ..... 0.07
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
SHNGL.ASPHLT
Asphault shingle roofing
0.44
0.44
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3.
PLY..0.50
0.50 in plywood
0.62
0.62
4.
AIR.RF.3.50
3'.5 in & greater air space: heat flow up
0.80
0.80
5c.
BATT.RII.0
R-11 batt insul (cavity > 3.5 in)
11.00
7-
5f.
FIR.2X4
2x4 in fir framing
--
3.46
6.
BATT.R8.0
R-8 batt insul (cavity > 3.5 in)
8.00
8.00
7.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.RF
Inside air film: heat flow straight up
0.61
0.61
Total Unadjusted R -Values
22.15
14.61
FRAMING ADJUSTMENT
CALCULATION
Cavity Framing Total
U -Value: (1 / 22.15 x 0.93) + (1 / 14.61 x 0.07) = 0.047
Btuh/sf-F
Total R -Value:
1 / 0.047 = 21..38
sf-F/Btuh
CONSTRUCTION ASSEMBLY Page 12 3R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZllS92 Program -FORM 3R
User#-MP1320 User-CALCTECH Run -Existing + Addition
Reference Name . MW.13.2X4.16
Description .... Wall R-13 2x4 16oc
Type ........... Wall
R -Value ........ 13 sf-F/Btuh
Framing
Material ..... FIR.2X4
Spacing :.. 16 inches on center
Fraction'...'.. 0.15
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
PART.BD.0.63
0.625 in particle board
0.82
0.82
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3c.
BATT.R13
R-13 batt insul (cavity = 3.5 in)
13.00
--
3f..
FIR.2X4
2x4 in fir framing
--
3.46
4.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.WLL
Inside air film: heat sideways
0.68
0.68
Total Unadjusted R -Values
15.18
5.64
FRAMING ADJUSTMENT
CALCULATION
Cavity Framing Total
U -Value: (1 / 15.18 x 0.85) + (1 / 5.64 x 0.15) = 0.083
Btuh/sf-F
Total R -Value:
1 / 0.083 = 12.11
sf-F/Btuh
CONSTRUCTION ASSEMBLY Page 13 3R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -FORM 3R
User#-MP1320 User-CALCTECH Run -Existing + Addition
Reference Name . AW.13.2X4.16
Description .... Wall R-13 2x4 16oc
Type ........... Wall
R -Value ........ 13 sf-F/Btuh
Framing
Material ..... FIR.2X4
Spacing ...... 16 inches on center
Fraction ..... 0.15
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value
R -Value
O. FILM.EX
Exterior air film: winter value
0.17
0.17
1. BLDG.PAPER
Building paper (felt)
0.06
0.06
2c. BATT.R13
R-13 batt insul (cavity = 3.5 in)
13.00
--
2f. FIR.2X4
2x4 in fir framing
--
3.46
3. GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I. FILM.IN.WLL
Inside air film: heat sideways
0.68
0.68
Total Unadjusted R -Values 14.36
4.82
FRAMING ADJUSTMENT
CALCULATION
Cavity Framing
Total
U -Value: (1 / 14.36 x 0.85) + (1 / 4.82 x 0.15) =
0.090 Btuh/sf-F
Total R -Value:
1 / 0.090 =
11.08 sf-F/Btuh
HVAC SIZING Page 14 HVAC
Project Title.......... Addition for Jackson Date........ 05/03/94
Project Address........ 6065 Upper Palermo Rd.
Oroville CA
Documentation Author... Neal Kuopus
Company ................ CALCTECH
Telephone .............. (916) 589-4219
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 11
Field Check Date
MICROPAS4 v4.02 File-JACKSOEA Wth-CTZ11S92 Program -HVAC SIZING
User#-MP1320 User-CALCTECH Run -Existing + Addition
GENERAL INFORMATION
FloorArea .................
Volume.. ..... ............
Front Orientation...........
Sizing Location............
Latitude... .... ........
Winter Outside Design......
Winter Inside Design.......
Summer Outside Design......
Summer Inside Design.......
Summer Range. .. ......
Interior Shading Used
Exterior Shading Used......
Overhang Shading Used......
Latent Load Fraction.......
1108 sf
8864 cf
Front Facing
OROVILLE RS
39.5 degrees
30 F
70 F
104 F
78 F
37 F
No
No
No
0.20
HEATING AND COOLING LOAD SUMMARY
Heating
Description (Btuh)
0 deg (N)
Cooling
(Btuh)
Opaque Conduction and Solar......
16942
8378
Glazing Conduction ...............
6067
3944
Glazing Solar ....................
n/a
5484
Infiltration .....................
5042
2070
Internal Gain ....................
n/a
1875
Ducts ............................
2805
2175
Sensible Load .................... 30856 23925
Latent Load ...................... n/a 4785
Minimum Total Load 30856 28710
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outdoor design temperatures, coil sizing, availability of
equipment, oversizing safety margin, etc., must also be considered. It is
the HVAC designer's responsibility to consider all factors when selecting
the HVAC equipment.
TABLE OF CONTENTS TOC
Project Title.......... Addition for Jackson Date........ 05/03/94
Project Address........ 6065 Upper Palermo Rd.
Oroville CA
Documentation Author... Neal Kuopus
Company ................ CALCTECH
Telephone .............. (916) 589-4219
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 11
Field Check/ -Date
MICROPAS4 v4.02 File-JACKSOEX Wth-CTZ11S92 Program -TOC
User#-MP1320 User-CALCTECH Run -Existing Residence
TABLE OF CONTENTS
Report Page
FORM C -2R ................. 1
FORM C -3R ................. 4
ADDITIONS ................. 7
COMPUTER METHOD SUMMARY Page 1 C -2R
Project Title.......... Addition for Jackson Date........ 05/03/94
Project Address........ 6065 Upper Palermo Rd.
Oroville CA
Documentation Author... Neal Kuopus
Company ................ CALCTECH
Telephone .............. (916) 589-4219
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 11
Field Check/ Date
MICROPAS4 v4.02 File-JACKSOEX Wth-CTZ11S92 Program -FORM C -2R
User#-MP1320 User-CALCTECH Run -Existing Residence
MICROPAS4
ENERGY USE
SUMMARY
Energy Use
Standard
Proposed
Compliance
(kBtu/sf-yr)
Design
Design
Margin
Space Heating..........
12.67
52.95
-40.28
Space Cooling..........
16.34
49.12
-32.78.
Total
29.01
102.07
-73.06
*** Water Heating not calculated ***
GENERAL INFORMATION
Conditioned Floor Area.....
Building Type ..............
Construction Type .........
Building Front Orientation.
Number of Dwelling Units...
Number of Building Stories.
Weather Data Type..........
Floor Construction Type....
Number of Building Zones...
Conditioned Volume.........
Footprint Area .............
Ground Floor -Area ......... I .
Slab -On -Grade Area.........
Glazing Percentage.........
Average Ceiling Height.....
955 sf
Single Family Detached
Existing
Front Facing 0 deg (N)
1
1
ReducedYear
Raised Floor
1
7640 cf
955 sf
955 sf
0 sf
15.8 % of FA
8 ft
BUILDING ZONE INFORMATION
Floor
Area Volume
Zone Type (sf) (cf)
HOUSE
Residence 955 7640
# of
Dwell Cond-
Units itioned
(Package E)
Vent Special
Thermostat Height Vent Area
Type (ft) (sf)
1.00 Yes NoSetback 2.0 n/a
COMPUTER METHOD SUMMARY Page 2 C -2R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEX Wth-CTZ11S92 Program -FORM C -2R
User#-MP1320 User-CALCTECH Run -Existing Residence
OPAQUE SURFACES
Area
U-
Insul
Act
Solar
Form 3
Location/
Surface
(sf)
value
R-val
Azm Tilt Gains
Reference
Comments
HOUSE - Existing
1
Wall
210
0.306
R-0
0
90 Yes
R.0.2X4.24
FRONT
2
Door
20
0.330
R-0
0
90 Yes
None
FRONT ENTRY
3
Wall
71
0.306
R-0
0
90 Yes
R.0.2X4.24
TO BE REMOVED
4
Wall
156
0.306
R-0
270
90 Yes
R.0.2X4.24
RIGHT
5
Wall
16
0.306
R-0
270
90 Yes
R.0.2X4.24
TO BE REMOVED
6
Wall
224
0.306
R-0
180
90 Yes
R.0.2X4.24
BACK .
7
Wall
68
0.306
R-0
180
90 Yes
R.0.2X4.24
TO BE REMOVED
8
Wall
62
0.306
R-0
90
90 Yes
R.0.2X4.24
LEFT
9
Wall
126
0.306
R-0
90
90 Yes
R.0.2X4.24
TO BE REMOVED
10
Floor
955
0.097
R-0
0
0 No
FC.0.2X6.16
TO CRAWLSPACE
11
Roof
955
0.047
R-19
0
0 Yes
R. 19.2X4.24
FLAT CEILING
FENESTRATION
SURFACES
# of
Vent
SC
Sc Interior
Area
Pan-
Frame
Open
U- Act
Glass
Int Shading/
Surface
(sf)
es
Type
Type
value Azm
Tlt Only
Shade Description
HOUSE - Existing
1
Window
6.3
1
Metal
Slider
1.190 0
90 1.00
0.88 Drapes.Std
2
Window
10.0
1
Metal
Slider
1.190 0
90 1.00
0.88 Drapes.Std
3
Window
10.0
1
Metal
Slider
1.190 0
90 1.00
0.88 Drapes.Std
4
Door
16.7
1
Glz<50%
Hinged
1.040 0
90 1.00
0.88 Drapes.Std
5
Window
36.0
1
Metal
Slider
1.190 270
90 1.00
0.88 Drapes.Std
6
Window
16.0
1
Metal
Slider
1.190 180
90 1.00
0.88 Drapes.Std
7
Window
6.3
1
Metal
Slider
1.190 180
90 1.00
0.88 Drapes.Std
8
Window
10.0
1
Metal
Slider
1.190 180
90 1.00
0.88 Drapes.Std
9
Window
20.0
1
Metal
Slider
1.190 180
90 1.00
0.88 Drapes.Std
10
Window
10.0
1
Metal
Slider
1.190 90
90 1.00
0.88 Drapes.Std
11
Window
10.0
1
Metal
Slider
1.190 90
90 1.00
0.88 Drapes.Std
OVERHANGS
AND SIDE FINS
Window-
Overhang
Left Fin Right Fin -
Area
Left Rght
Surface
(sf)
Hght
Wdth
Dpth
Hght
Ext Ext
Ext Dpth
Hght Ext Dpth Hght
HOUSE - Existing
1
Window
6.3
2.5
2.5
20
0.8
n/a n/a
n/a n/a
n/a n/a n/a n/a
2
Window
10.0
4
2.5
20
0.8
n/a n/a
n/a n/a
n/a n/a n/a n/a
3
Window
10.0
4
2.5
1.3
1
n/a n/a
n/a n/a
n/a n/a n/a �n/a
4
Door
16.7
6.7
2.5
1.3
1
n/a n/a
n/a n/a
n/a n/a n/a n/a
6
Window
16.0
4
4
1.3
1
n/a n/a
n/a n/a
n/a n/a n/a n/a
7
Window
6.3
2.5
2.5
1.3
1
n/a n/a
n/a n/a
n/a n/a n/a n/a
8
Window
10.0
4
2.5
1.3
1
n/a n/a
n/a n/a
n/a n/a n/a n/a
9
Window
20.0
4
5
1.3
1
n/a n/a
n/a n/a
n/a n/a n/a n/a
COMPUTER METHOD SUMMARY Page 3 C-2R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEX Wth-CTZ11S92 Program -FORM C -2R
User#-MP1320 User-CALCTECH Run -Existing Residence
HVAC SYSTEMS
Minimum Duct
System Type Efficiency Location
HOUSE
Furnace 0.750 AFUE Attic
ACSplit 8.0.0 SEER Attic
SPECIAL FEATURES/REMARKS
Duct. Duct
R -value Efficiency
R-2.1 0.780
R-2.1 0.740
R-2.1 existing duct insulation '
R-0 existing floor insulation per Form 3
R-0 existing wall insulation per Form 3s
R-19 existing ceiling insulation per Form 3
Opaque U -values per CEC TABLE 7-2 for pre -1978 construction
Glazing U -values per CEC TABLE 7-2 for pre -1978 construction
E.FURN.75: per CEC TABLE 7-2 for pre -1978 construction
E.AC.8.0: CEC MIN. REQUIREMENT
HWH: NOT ALTERED - NO CALCULATIONS
CONSTRUCTION ASSEMBLY - Page 4 3R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEX Wth-CTZ11S92 Program -FORM 3R
User#-MP1320 User-CALCTECH Run -Existing Residence
Reference Name . R.0.2X4.24
Description .... Roof R-0 2x4 24oc
Type ........... Roof
R -Value ........ 0 sf-F/Btuh
Framing
Material ..... FIR.2X4
Spacing ...... 24 inches on center
Fraction ..... 0.07
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Name Description
0.
FILM.EX
Exterior air film: winter value
1.
SHNGL.ASPHLT
Asphault shingle roofing
2.
BLDG.PAPER
Building paper (felt)
3.
PLY.0.50
0.50 in plywood
4.
AIR.RF.3.50
3.5 in & greater air space: heat flow up
5c.
RO.PLACEHOLD
R-0 PLACE HOLDER
5f.
FIR.2X4
2x4 in fir framing
6.
GYP.0.50
0.50 in gypsum or plaster board
I.
•FILM.IN.RF
Inside air film: heat flow straight up
Total Unadjusted R -Values
FRAMING ADJUSTMENT CALCULATION
Cavity Framing
Cavity Frame
R -Value R -Value
0.17
0.17
0.44
0..44
0.06
0.06
0.62
0.62
0.80
0.80
0.00
--
--
3.46
0.45
0.45
0.61
0.61
3.15 6.61
Total
U -Value: (1 /
3.15 x 0.93) + (1 / 6.61
x 0.07) =
0.3.06
Btuh/sf-F
Total R -Value:
1 /
0.306 =
3.27
sf-F/Btuh
CONSTRUCTION ASSEMBLY - Page 5 3R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEX Wth-CTZ11S92 Program -FORM 3R
User#-MP1320 User-CALCTECH Run -Existing Residence
Reference Name . FC.0.2X6.16
Description .... Floor Crwl R-0 2x6 16oc
Type ........... Floor
R -Value ..... 0 sf-F/Btuh
Framing
Material ..... FIR.2X6
Spacing ...... 16 inches on center
Fraction ..... 0.10
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
CRAWLSPACE
Effective R -value of vented craw.lspace
6.00
6.00
2c.'
RO.PLACEHOLD
R-0 PLACE HOLDER
0.00
--
2f.
FIR.2X6
2x6 in fir framing
--
5.45
3.
PLY.0.63
0.625 in plywood
0.77
0.77
4.
CARPET
Carpet & pad
2.08
2.08
I.
FILM.IN.FLR
Inside air film: heat flow down
0.92
0.92
Total Unadjusted R -Values
9.94
15.39
FRAMING ADJUSTMENT
CALCULATION
Cavity Framing Total
U -Value: (1 / 9.94 x 0.90) + (1 / 15.39 x 0.10) = 0.097
Btuh/sf-F
Total R -Value:
_ 1 / 0.097 = 10.30
sf-F/Btuh
CONSTRUCTION ASSEMBLY Page 6 3R
Project Title.......... Addition for Jackson Date........ 05/03/94
MICROPAS4 v4.02 File-JACKSOEX Wth-CTZ11S92 Program -FORM 3R
User#-MP1320 User-CALCTECH Run -Existing Residence
Reference Name . R.19.2X4.24
Description .... Roof R-19 2x4 24oc
Type ........... Roof
R -Value ........ 19 sf-F/Btuh
Framing
Material ..... FIR.2X4
Spacing ...... 24 inches on center
Fraction ..... 0.07
Sketch of Construction Assembly
LIST OF CONSTRUCTION COMPONENTS
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
U -Value: (1 / 22.15 x 0.93) + (1 / 14.61 x 0.07) = 0.047 Btuh/sf-F
Total R -Value: 1 / 0.047 = 21.38 sf-F/Btuh
Material
Cavity
Frame
Name
Description
R -Value
R -Value
0.
FILM.EX
Exterior air film: winter value
0.17
0.17
1.
SHNGL.ASPHLT
Asphault shingle roofing
0.44
0.44
2.
BLDG.PAPER
Building paper (felt)
0.06
0.06
3.
PLY.0.50
0.50 in plywood
0.62
0.62
4.
AIR.RF.3.50
3.5 in & greater air space: heat flow up
0.80
0.80
5c.
BATT.RII.0
R-11 batt insul (cavity > 3.5 in)
11.00
--
5f.
FIR.2X4
2x4 in fir framing
--
3.46
6.
BATT.R8.0
R-8 batt insul (cavity > 3.5 in)
8.00
8.00
7.
GYP.0.50
0.50 in gypsum or plaster board
0.45
0.45
I.
FILM.IN.RF
Inside air film: heat flow straight up
0_61
0.61
Total Unadjusted R -Values
22.15
14.61
FRAMING ADJUSTMENT CALCULATION
Cavity Framing Total
U -Value: (1 / 22.15 x 0.93) + (1 / 14.61 x 0.07) = 0.047 Btuh/sf-F
Total R -Value: 1 / 0.047 = 21.38 sf-F/Btuh
ADDITION WORKSHEET Page 7 ADD
Project Title.......... Addition for Jackson Date........ 05/03/94
Project Address........ 6065 Upper Palermo Rd.
Oroville CA
Documentation Author... Neal"Kuopus
Company ................ CALCTECH
Telephone .............. (916) 589-4219
Compliance Method...... MICROPAS4 by Enercomp, Inc.
Climate Zone........... 11
Field Check/ Date
MICROPAS4 v4.02 File-JACKSOEX Program -ADDITIONS
User#-MP1320 User-CALCTECH Run -Existing + Addition
ADDITION WORKSHEET - COMPUTER PERFORMANCE
EXISTING
File Name .................. JACKSOEX
Run Title.. ... ........ Existing Residence
Conditioned Floor Area..... 955 sf
Standard Design Energy Use. 29.01 kBtu/sf-yr
Proposed Design Energy Use. 102.07 kBtu/sf-yr
NEW (EXISTING PLUS ADDITION)
File Name .................. JACKSOEA
Run Title. ..... ....... Existing + Addition
Conditioned Floor Area..... 1108 sf
Standard Design Energy Use. 31.01 kBtu/sf-yr
Proposed Design Energy Use. 75.40 kBtu/sf-yr
FLOOR AREA RATIO
Floor
Existing New Area
Floor Area Floor Area Ratio
955 / 1108 = 0.862
ADDITION DESIGN ENERGY USE FOR NEW (EXISTING PLUS ADDITION)
Floor
New Area Existing Existing
Standard Ratio Proposed Standard
31.01 + 0.862 x ( 102.07 - 29.01) _
Addition
Design
93.98
Note: If (Existing Proposed - Existing Standard) is
negative, this difference is set to zero.
ADDITION ENERGY USE SUMMARY
Energy Use
(kBtu/sf-yr)
New....................
Addition Proposed Compliance
Design Design Margin
93.98 75.40 18.58
*** Addition complies with Computer Performance ***