HomeMy WebLinkAbout079-290-030Department of Development Services Building Division 7 County Center Drive Oroville, CA 95965 (530) 538-7541 (530) 538-2140 FAX Residential Construction Requirements IMPORTANT This set Iof plans and specifications MUST be kept on the job site at all times and it is unlawful to make any changes of alterations on same without written permission from the Building Division, County of Butte. All materials and workmanship shall be in accordance with recognized good practices and of a quality prescribed for the specific use in the 1998 California Building Code (1997 U.B.C.), 1998 California Plumbing Code (1997 U.P.C.), 1998 California Mechanical Code (1997 U.M.C.), and the 1998 California Electrical Code (1996 N.E.C.) COMPLY WITH ITEMS INDICATED BELOW ❑ Your parcel lies within a designated 100 -year flood plain. Finish floor, electrical, HVAC equipment and services shall be a minimum of one foot above the elevation shown on the attached Flood Elevation Certificate. A Post Flood Elevation Certificate will also be required Note: We will normally accept the following as compliance with the flood elevation requirements: 1. Building is anchored to concrete stemwall system with conventional anchor bolts. 2. Building plate on top of stemwall to be one foot or more above the 100 -year flood elevation. (Plate height less than 24" above grade, or engineered design required). 3. Electrical, heating, ventilation, plumbing and air conditioning equipment and facilities located above the plate. 4. At least 2 openings in exterior walls, located on opposite or adjacent walls with a total net area of not less than 1 square inch for every square foot of enclosed area. 5. The bottom of the openings shall be no higher than 1 foot above grade. 6. The openings may be screened or covered with other devices that will permit automatic entry and exit of floodwater. ❑ The following parcel map requirements shall be met: ® All structures and equipment shall be clear of all easements. A setback of 5' from the side and 5' from the rear property lines and 20 feet (25 feet if Federal Aid Route) from the edge of the right of way shall be clear of structures and equipment except for a 2 foot overhang. ® Expansive soil may be encountered on this site. This condition may require the foundation to be designed by a California registered engineer or licensed architect. BUILDING PPROO Page I of I Owners Name: Jackson Building Permit Number: 01-1164 Plans Examiner: Glenn Gibbons TO: FROM: SUBJEC Building Department Environmental Health ;T: Sanitation Clearance E.H. USE ONLY Mat Man Attached ,lC.S Haar Man AKaeM1 ala Sant to S.D. Owner Location APS Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for, dwelling. Other Hold final for: Final clearance O.K. for: NOTE: r - Environmental Health Speciali •: „,� Date BACHMAN MAY 18, 2001 COUNTY OF BUTTE Department of Building 7 County Center Drive Oroville, CA 95965 RE: HOLIDAY POOLS Brad Jackson 45 Circle View Drive Oroville, CA 95965 Attn: Dave Wasney ASSOCIATES Dear Dave: I have reviewed the pool that holiday pools is building for Mr. Jackson on 45 Circle View Drive. As you know, the standard pool drawing allow for a 3 foot above ground installation. On this pool after all excavation, a portion of the pool ended up with a small area that is between 3 to 4 feet. A.- gOV E NA Nom{, GRApE I have asked Jim, to put 3 - #4 in the bond beam and run the stiru s at 12 inches on center and continue down the out side of the pool. Run the horizontals at 12 inch on centers. This show run from the 'skimmer about 25 feet toward the shallow end. If I can answcr any, please let me know. Very, tru urs,- .., . yrs r RCE #16803 13647 GARNER LANE CHICO, CA 95973 G' E 1V 1, ENGINEERING SURVEYING 3012 The Esplanade, Chico, California 95926 MiR17TE COi1Pti'V SU1DtNG DEP ,,, APPROVED • PLANNING DESIGNING • Telephone: (916) 342-4136