Residential Construction Requirements
IMPORTANT
This set Iof plans and specifications MUST be kept on the job site at all times and it is unlawful to make
any changes of alterations on same without written permission from the Building Division, County of
Butte.
All materials and workmanship shall be in accordance with recognized good practices and of a quality
prescribed for the specific use in the 1998 California Building Code (1997 U.B.C.), 1998 California
Plumbing Code (1997 U.P.C.), 1998 California Mechanical Code (1997 U.M.C.), and the 1998 California
Electrical Code (1996 N.E.C.)
COMPLY WITH ITEMS INDICATED BELOW
❑ Your parcel lies within a designated 100 -year flood plain. Finish floor, electrical, HVAC equipment and services shall
be a minimum of one foot above the elevation shown on the attached Flood Elevation Certificate. A Post Flood
Elevation Certificate will also be required
Note: We will normally accept the following as compliance with the flood elevation requirements:
1. Building is anchored to concrete stemwall system with conventional anchor bolts.
2. Building plate on top of stemwall to be one foot or more above the 100 -year flood elevation. (Plate height less than 24"
above grade, or engineered design required).
3. Electrical, heating, ventilation, plumbing and air conditioning equipment and facilities located above the plate.
4. At least 2 openings in exterior walls, located on opposite or adjacent walls with a total net area of not less than 1 square
inch for every square foot of enclosed area.
5. The bottom of the openings shall be no higher than 1 foot above grade.
6. The openings may be screened or covered with other devices that will permit automatic entry and exit of floodwater.
❑ The following parcel map requirements shall be met:
® All structures and equipment shall be clear of all easements.
A setback of 5' from the side and 5' from the rear property lines and 20 feet (25 feet if Federal Aid Route) from the
edge of the right of way shall be clear of structures and equipment except for a 2 foot overhang.
® Expansive soil may be encountered on this site. This condition may require the foundation to be designed by a
California registered engineer or licensed architect.
BUILDING
PPROO
Page I of I
Owners Name: Jackson
Building Permit Number: 01-1164
Plans Examiner: Glenn Gibbons
TO:
FROM:
SUBJEC
Building Department
Environmental Health
;T: Sanitation Clearance
E.H. USE ONLY
Mat Man Attached ,lC.S
Haar Man AKaeM1 ala
Sant to S.D.
Owner Location APS
Plan Approved for: Sewage Disposal Water Supply: Public Private Well
Clearance for, dwelling. Other
Hold final for:
Final clearance O.K. for:
NOTE:
r -
Environmental Health Speciali
•:
„,�
Date
BACHMAN
MAY 18, 2001
COUNTY OF BUTTE
Department of Building
7 County Center Drive
Oroville, CA 95965
RE: HOLIDAY POOLS
Brad Jackson
45 Circle View Drive
Oroville, CA 95965
Attn: Dave Wasney
ASSOCIATES
Dear Dave: I have reviewed the pool that holiday pools is building for Mr. Jackson on 45 Circle View
Drive.
As you know, the standard pool drawing allow for a 3 foot above ground installation. On this pool after all
excavation, a portion of the pool ended up with a small area that is between 3 to 4 feet. A.- gOV E NA Nom{, GRApE
I have asked Jim, to put 3 - #4 in the bond beam and run the stiru s at 12 inches on center and continue
down the out side of the pool. Run the horizontals at 12 inch on centers. This show run from the
'skimmer about 25 feet toward the shallow end.
If I can answcr any, please let me know.
Very, tru urs,- ..,
. yrs r
RCE #16803
13647 GARNER LANE
CHICO, CA 95973
G' E
1V 1,
ENGINEERING SURVEYING
3012 The Esplanade, Chico, California 95926
MiR17TE COi1Pti'V
SU1DtNG DEP ,,,
APPROVED
• PLANNING DESIGNING
• Telephone: (916) 342-4136