HomeMy WebLinkAbout079-290-077rQ - .g�2 BPE .
,.BRYANT, JIM .& CAROL
MT IDA' Rl�, OROVILLE
CONTR: DAN & CRAIG HILL
GARAGE/CARPORT v -a c1 3
77
RESIDENTIAL
036-13-0-138 93-322 BPE
BA� , JIM & CAROL
S MT IDA RD, OROVILLE
CONTR: DAN & CRAIG HILL
GARAGE/CARPORT 3 -
JOB _
JOB
Sig
s
V=OK
O=Not OK
=
Not Readyab1e MOBILE HOMES
Date/Initials MOBILE HOME UTILITIES (Plans) OK except #'s °
1. Zoning Requirements -Setbacks -Easements
2. Soils; Special MH Support Sketch
3. Sewer; Location -Test -Fell -C/O Concrete
4. Water; Location -Test -Easement Needed (Sketch)
5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete
6. Gas; Location -Test -Wrap: / /"L"ft.
/ /"Nat. or/ /"L"ft./ /"LPG
7. Well Clearance & Disconnect
8. Utility Clearance
Date/Initials MOBILE HOME INSTALLATION (Plans) OK except #'s
1. Zoning Requirements -Setbacks Easements
2. Footings; Size -Spacing -Marriage Line
3.. Gas; MH Test -Demand -Valve -Connector
4. Electricity; MH Teat -Crossovers -Breakers -Clearances
5. Drain; MH Test -Fall -Flex Connector
6. Water; MH Test -Regulator -Connector
7. Water and Sewer Connected -C/O to Grade -HD Approval
8. Gas and Electricity Tagged
9. Exits; Insp.-Sketch
10. Cert. of Occupancy
MISCELLANEOUS
Date/Initial DECKS COVERS CARPORTS GARAGES Plana OK except #'a
1. Zoning Requirements -Setbacks -Easements
2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel
3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails
4. Wood Awn.; Posta-Beams-Rftm. Connectors
Shthg: Rfg :Bracing
5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures
6. Cgrports; Windows -Doors
lectrid"
rmg; Sils-Anchors-Studs-Rftm-Trusses
9. Siding; Nailing -Veneer -Stucco -Mesh
10. Roof; Shthg-Roofing
11. Ext.; Steps -Doors -Landings
Date/Initials POOLS (Plans) OK except #'a
1. Setbacks -Easements
2. Soils; Compaction -Structure Stability
3. Pool Structure; Steel -Connections -Thickness
Dead Men -Lining
4. Elec.; Receptacles and Lighting, Distances-GFI
5. Elec.; Pool Lighting; 15 volts-GFI
6. Elec.; Enclosures; Conduit Entries -Terminals -Listed
7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater
8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg.
Boxes-Enclosures-Panelboards-Ins. to Main in Conduit
9. Health Department Approval
10. Plumb.; Cir. Test -Water Supply Test
V=OK
O=Not OK
= Not Not Applicable RESIDENTIAL
ReaDate/Initials UNDERFLOOR (Plans) OK except #'s
1. Zoning -Setbacks -Easements -Flood -Slope
2. Ftg., Main; Soils-Elec. Grnd.-/ P' Ftg. Depth
3. Ftg., Garage; Soils-Steel-Elec. Grnd. / /" Ftg. Depth
4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth
5. Stemwalls, Main; Steel -Bloc kouts-Wrapped
6. Stemwalls, Garage; Steel-Blockouts-Wrapped
6a. Hold Downs and Special Anchors
7. Slab; Steel -Wrapped
8. Piers -Fireplace Ftg.-Steel
9. D.W.V.; Fall -Fitting -Teat -2 Way C/O -Sewer Test
10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test
11. Water Pipe; Test -Anchor -Regulator -Service Test
12. Electric; Underground
13. Plenums & Ducts; Clearance -Material -Support -Ins.
14. Girders -Sills -Anchor Bolts-Joists-Vents-CrioDles
15. Access & Ventilation
16. Insulation
Date/Initials PLUMBING (Permit) OK except #'s
16. Water Htr.; Vent -Access -Combustion Air -Baffle
17. Water Pipe; Test & Anchor -Nail Protection
18. D.W.V.; Test -Fittings & Anchor-Naii Protection
19. Shower Pan; Test, First Floor -Tub Access
20. Test Tub & Shower, Second Floor -Tub Access
21. Gas Pipe; Size & Anchors
Date/initials ELECTRICAL (Permit) OK except #'s
22. Fixture & Transformer Clearance -Ins. Protection
23. Elec. Receptacles Spacing -Lights & Switches at Doors
24. Size Boxes & No. of Conductors -Stapled
25. Romex Installed Close to Edge of Studs & C.J.
26. Equip. Ground made up w/Meth. Fastners-Bond Gas & Water
27. 2 Appliance Circuts in Kitchen & Conductor Size/GFI
28. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga.
Cu or Al
29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al.
Insulated Neutral ❑ Yes ❑ No
30. Service -Riser Conductors & Ground -Main Disconnect
31. Equip. Clearances Panels -Motors -Meth. Equip.
32. Clothes Closet Light -Shower Light -Spa Light
33. Smoke Detector
Date/Initials MECHANICAL (Permit) OK except #'s
34. A.C. Ducts Insulation & Support
35. Vent Fan; Exhaust above insulation
36. Condensate Drain & Overflow; Size & Grade
37. Furnance-Vent; Access -Comb. Air -Return Air Vent -115 outlet
38. Attic Access & Platform if Furnance in Attic
Date/Initials FRAMING (Plans) OK except #'s
39. Sils, Proper Material & Anchors
40. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound
41. Bearing Walls over Girders & Floor Nailing
42. Draft Stop in Walls (rat proof)
43. Fire Stops; Furred Ceilings -Stairs -Chases -Tub
44. Headers & Beam -Size & Bearing
Single & Duplex)
Date/Initials FRAMING (Continued)
45. HSngers-Post Ceps -Anchors -Connectors
46. Cing. Joist-Rftr. ties- Puri in -roof Brac-Truss-Shthng.-Rfng.
47. Fireplace Ties or Type A Flue -Fireplace Throat clearance
48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles
49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions
50. Garage Fire Protection Framing
51. Property Line Firewall & Openings
52. Ext. Doors -One T -Check Garage -3rd Story, 2 Exits
53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection
54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers
55. Siding -Nailing Veneer
56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access
57. Glazing Area -Glass Protection -Skylights -Plastic
58. Shear Walls; Nailing -Bolts
59. Insulation -Wells -Ceilings
60. Infiltration -Walls -Windows
Date/Initials FINAL (Plans) OK except #'s
61. Ext. Steps -Door & Sidelight Protection -Landings
62. Smoke Detector
63. Furnace; Vents -Clearance -Comb. Air -Connector -
In Garage; Above Floor -Ducts -Mach. Protection
64. Bedroom Exiting
65. G.F.I. & Bath Fixtures & Tub Access -Spa
66. Elec. Trim & Subpanel; Breaker Sizes & Labels
67. Stairs & Rails
68. Fireplace or Stove; Clearances -Hearth
69. Elec. Outlets at Wood Panel; Int. & Ext.
70. Kit.Fixt. & Appliance; Grnd -Air Gap -Cooking Clearance
71. Elec. Outlets & Receptacles at Kit. Counter
72. Garage Fire Door; Swing -Landing -Closer
73. A.C. Duct in Garage -Damper
74. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.
In Garage; Above Floor-Mech. Protection
75. Plb., Elec. & Mach. Equip. Listed for Location
76. Elec. Receptacles in Garage; (G.F.I.)-Romex Protection
77. Insulation -Foam -Looked in Attic ❑ Yes
78. Guard Rails & Deck Construction -Post Caps
79. Fdn. Vents & Crawl Hole Door-Drainagge & Wood -Earth
Clearance Looked under Floor ❑ Yes
80. Following instld.; Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No;
Planters ❑ Yes ❑ No
81. Stucco; Brown -Finish
82. A.C. Unit; Disconnect, Electrical, Plumbing
83. Vents Above Roof; Plbg.-Appliance-Fireplace-Clearance to
Openings
84. Water Well; Disconnect, Electrical, Plumbing
85. Exterior Elec. Trim; G.F.I. Receptacle -Underground
86. Ventilation Throughout House
87. Glass Protection
88. Corrections from Previous Inspections
89. Gas Test -Meters Tagged; Gas -Electric
90. Water & Sewer Connected -C/O to Grade -HD Approval
91. Energy Compliance Certificate -Other Certificates
Comments at Final:
�r:,tT..:lcr.is-.wit+er4.r�..vF$s�w.•..c,-�'�,-S" i.�"'�,+�•a......-��'•i.�..�..:..,......;� ,.. w �.�� _�
COUNTY OF BUTTE
BUILDING DIVISION
03PARTMENT OF DEVELOPMENT SERVICES
11469 Rmnboldt Road, Chico, CA - (916) 891-2751
7 Cb m tV Center Drive, Oroville, CA - (916) 538-7541
747 Effa t•Road, Paradise, CA - (916) 872-6307
CORRECTION NOTICE
II>�6 PERMIT NO.
Anmi&npmffimkAcaustutdmfoUoviingviWafwmof Butte County Ordinances exist at
tfl� afbm� a ami afrouid he corrected. Please
rwtify this office when correction of work
isamn1kmaeanyquestiorrspertainurgtothis matter,orneed additional explanation-,
t&k i= omedately_
Ax
L--t/� T a
1
htspector
0"UIQ
s
r
COUNTY OF BUTTE - DE-PARTkE',NT OF PUBLIC WORKS
�•. 7 County Center Drive - Oroville, California 95965 - Telephone: 916/538-7541
APPLICATION AND PERMIT
PERMIT NO.
ASSESSOR PARCEL NUMBER
036-130-138
ZONING
AR -5
BUILDING PERMIT
OWNER
Brsyant
TELEPHONE
534-9054
SO. FT. OCC. BUILDING VALUATION
OWNS MAILING ADDRESS
295 Mt. Ida Rd., Oroville 95965
M
352. C 4,576.00
CONTRACTOR'S NAME
Craig & Dan Hill Construction
TELEPHONE
534-8217
CONTRACTOR'S MAILING ADDRESS
3 Serra Monte Dr., Oroville 95966
Fireplace
CONSTRUCTION LENDER
UNKNOWN
Total Valuation $
LENDER'S MAILING ADDRESS
ARCHITECT OR ENGINEER LICENSE No.
Filing Fee I $ 15 .00
Permit Fee 2 $ 1.
Plan Checking Fee $
ARCHITECT OR ENGINEER'S MAILING ADDRESS
Energy Plan Checking Fee $
Penalty $
BUILDING ADDRESS
Permit fee $
Mt- Ida Rd- Oroville
PLUMBING PERMIT Filing Fee 15.00
Each Trap 1 5.00
Solar or heat pump water heater 20.00
LOT NO.
SUBDIVISION NAME
PARCELMAPWater
-7, !/
piping 1 7.00 7.00
Each qas water heater.or vent 7.00
USE OF STRUCTURE
SF ❑ Duplex❑ Mobilehome❑ Other QaragP�Carnnrt
SPECT v
Gas piping system 1 - 5 outlets 5.00
Building sewer 15.00
Mobile Home S I G W @ 15.00
TYPE OF WORK
NewXM Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other ❑
Describe work: Garage/Carport
Permit Fee $ 22.00
Contractor
ELECTRICAL PERMIT Filing Fee 15.00
Main service 200AORLESS 18.50
CONTRACTORS LICENSE LAW
der penalty of perjury (check one):
I dec;,�Iamlicensed under provisions of Chapt. 9, Div. 3 of the BuslnesS
and Professions � C,rry�o-dye and my license is in full force and effect.
License No. �11�1J F� Classification �i tr
ElFIXED
I, as the owner, or my employees with wages as their sole compen-
sation, will do the work,and the structure is not intended or offered
for sale. (Sec. 7044)
❑ I, as the owner, am exclusively contracting with licensed contract -
ors. (Sec. 7044)
❑ 1 am exempt under Sec. , Business and Professions Code
for this reason
Main service 200A TO 1000A) 37.50
NEW CONST. ( DWELLING OCCUP.a\ `r 3.64 sq.ft. 1 5
OR ADDNS. ACC. BLOGS. II A
NEW CONSTP- ULT' -OUTLET @ 5.00
NON .RESID BRANCH CIRCUITS)
(POWER APPARATUS el
SINGLE OUTLET CIR. /
Ex. Occup(OUTLETS OR FIXTURES 20 76
APPLNS. OR
EX. Occup. OUTLETS (RESID.) EA.) 3.00
Temporary service 15.00
Mobile Home Facilities 15.00
Misc. Wiring -15.00
Future Use
Permit Fee $
WORKMEN'S COMPENSATION INSURANCE
I declare under penalty of perjury (check one):
permit is for $100.00 (valuation) or less.
have placed on file with the County of Butte Building Department
a Certificate of Workmen's Compensation Insurance or a Certificate
of Consent to Self -Insure.
❑ I shall not employ any person in any manner so as to become subject
to the W. C. laws of California.
Notice to Applicant: If after making this statement, should you become subject
to the W. C. provisions of the Labor Code, you must forthwith comply with such
provisions or this permit shall be deemed revoked.
Contractor
MECHANICAL PERMIT Filing Fee 15.00
Heating
Cooling
Hood 6.50
Ventilation
Permit Fee $
Contractor
I certify that I have read this application and state that the above information
is correct. I agree to comply to all County Ordinances and State Laws relating
to building construction, and hereby authorize representatives of the Countyot
Butte to enter upon the above-mentioned property for inspection purposes.
I also agree to save, indemnify and keep harmless the County of Butte against
all liabilities, judgments, costs, and expenses which may in any way accrue
against said Count i nsequence of the granting of this permit.
X C Date � A�
Signature of Applicant — Owner ❑ Contractor (�` Agent ❑
n of structures over 3 stories in height. % 3 G 6�
�An OSHA permit is required for excavations over S'0" dee and demolition or con"sR(ct-
Mobile Home Installation Fee S
Energy Inspection Fee $
occ
CONST TYPE
TOTAL FEE $ 234 0
I FLOOD I CDF PARC PD HD SSU
This ermit is hereb issued under the applicable rovi-
p Y PP p
sions of the Bu Cc ode and/or resolutions to do
work Indic a which fees have been paid.
OF PUBLIC WORKS
By Date
PE IT EXPIRES Date
eceipt No. 135329
'
,ITE-D.P.W., YELLOW -ASSESSOR. PINK -INSPECTOR GOLDENROD -APPLICANT
II
�+� `l. �.-:'..�rr�-v-i"r,.rn.��.;Y`"�.'�Y"_�Y-•n_�..".�r.,jt.�w.-,F..�YI .^+''e.�M+"".++i..%�...� :A � �'i�.r..�`' _ 'i'� �� ;�..
I J
COUNTYOF B TTE - DEPARTMENTOF DIeOPMENTSERVICES -BUILDING DIVISION
7 CSO NTY CENTER DR1 E 1bROVILLE, CALIFORN1495965 -TELEPHONE (916) 538-7541
PERMIT APPLICATION DATA SHEET
OWNERy' / A eD (CIA M � � A. P. No. osrc (98
Proposed Building Use I lAmve S/► up Building Inspector_, ,5� Date 11 tO 9-3
4
At time of permit application, I was advised the following data must be submitted prior to permit processing'and/or issuance:
DATE RECEIVED BY
1. All items have been submitted . ........................................
2. Plot plans, 3/4 sets, signed by preparer of plans. ......................... .
3. Complete plans, 3/4 sets, signed by preparer of plans . ......................
.4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . .............
5. Hazardous Material Form . ........................................... .
6. Energy Design Compliance and supporting documentation . ..................
7. Statement of Intent for Non -Heated and A/C Buildings . ...................... ,
8. Engineered truss details and layout in duplicate (required prior to plan check). ....
9. Mobilehome data and manufacturer's installation instructions, 2 sets. ...........
10. Fees of $ ..........................................
11. Impact fees as shown on attached schedule . ..............................
12. California Department of Forestry plan approval/fees. ....................... .
13. Flood elevation letter (100 year flood) by California Engineer . ............... ::
14. Sanitation and plot plan approval OR'o�i,�� Health Department. ............
15. City of Chico plumbing permit . .........................................
16. Plot plan and business license approval from City of Biggs/Gridley. .............
17. Planning approval for (A) Use: (B) Parking: . ........
18. Contact Land Development.about (A) Improvements (B) Drainage. .......... .
19. Driveway permit (construction approval required prior to occupancy). .. .. .. .
20. Pre -inspection for P��"�e�O" �QO�-
regUlred. . . to Building Inspector s (Date)
r 21. Contractor's license information. (No., Name Style, Classification) . .............. le, r
22. Certificate of Wolrkmans Compensation Insurance . ..........................
23. Owner -Builder Verification (Given to owner , Mail to owner )............
24. Recorded copy of Agricultural Acknowledgement Statement . ..................
25. Letter of signature authorization . ....................................... .
26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .. `.. .-
27. Letter of intent on building use . ........................................ .
28. Mobilehome utility clearance . ..................
.......................
29. Documentation of legal access . :....................
30. Documentation of 50% subdivision developed or (A) Road improvements completed
and (B) Parcel meets zoning area and frontage requirements . ...............
31. Existing violations/expired permits . ......................................
32. Plan check list . .....................................................
M 33
34.
When you issue the permit, process as follows: Mail to owner. Mail to contractor. •
Telephone 153V_&`117 and hold for pickup at OQ-o.�ijLc- office. Deliver with inspector.
Other
Parcel Creation
Acreage Applicant Date 2
Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date
Copy of plans sent Health Dept. Fire Dept. Other Date By
The following data must be submitted prior to permit issuance: (Circle new item not checked above).
1. Index permit for above item .,No.
2. Additional items required: Sd��/7 7i�.rS Q c/vs >!1mu� cr/,'/� y� f/1� « F�e.� o� "a a
iy£ �.eic�� Coil .�i� Gc2osr.�7
Cont or . designer, owner, was advised of above required data by L_ one _ mail Counter by ate 9-/,P
Contr or, designer, owner, was advised of above required data by c -phone' ' mai Counter by ?Date Z_ 3
Plans checked by Date Pf 0 s approved by !�1 Datel3
Sets of plans on hold in File cabinet AP folder
Copy - Department of Public Works
1'0: Building Department
FROM: Environmental Health
SUBJECT: Sanitation Clearance
T, NI. ?4Y"
Owner
Ii.Ii.IISItlN'l.
P6d flan Attached
11w)e flan Atutched
Scott at II.U. _/-gL—J -- —3
:n /f 036-1-:V-13,9
Location Did , API#
Plan Approved for: Sewage Disposal
Clearance for
Fater Supply: Public
r `P, r3 K.
Priva_t, Well
C -S Avlt4Gc.
Hold final for:
Final clearance O. K
NOT
Environmental Health Spt!
8/92
alis[ Date
17
NO.TES.FLOORS B D TW T
ONE 12" 12" 6" 6"
f. IF00T1NGS TO BE EXCAVATED INTO TWO 15" 18" 8" 7"
UNDISTURBED SOIL TO DEPTH D
• FLOORS REFERS TO NUMBER OF
2.. ANCHOR BOLTS SHALL BE PER UBC FLOORS PER UBC TABLE 29—A,
SEC. 2907 (f) F00 TNO TE J.
J. STEM HEIGHT OVER 32" REQUIRES
REINFORCING (SEE STD 12.3)
4. SEE UBC SEC 2404 (f) -2 FOR `
CONCRETE' BLOCK STEM WALL
I'
6" MIN
6" MIN
JOIST
18" MIN
rovEde '/�z" x f 0" fnchw bong
B @ '6'0,C. max. and W#jam
12 -of okft
AISED FLOOR FOOTIN
RED WOOD. OR
P. T. SILL , 3 1/2" SLAB
8urrE cNV
BUILDItVG DEP FITMENT
D
APP R
� B
SLAB ON GRADE FOOTING
TYPICAL RE`'DENTIAL FOUNDATION DETAILS
; ' ; s;D,
scatE .1/4' -t' -o'
IDATLO. 4/92
BUTTE-CC'_6'.v'--T;:':3UILDING DEPARTMENT
DWG. S7DF7G1
I STD 12.1
k4lfl
i
:i - —A-
itt f7 3zz
,TOP -CHORD '2X4 FIR -LARCH O1
BOT -CHORD 2X4) FIR -LARCH /1
WEBS 2X4 FIR -LARCH Standard
�} REQUIREMENTSAOFSI'.1CS8.OE INSTALLED IN WITH
ALL PLATES ARE CENTERED ON JOINT UNLESS OTHERWISE INDICATED.
SEE ORWGS. 130 6 160/160A -F FOR TYP. PLATE LOCATION DETAILS.
TOP CHORD SHALL BE LATERALLY BRACED WITH PROPERLY CONNECTED
PURLINS SPACED AT A MAXIMUM OF 244 O.C.
NO E:�2X4 03 HEM -FIR OR BETTER CONTINUOUS LATERAL., BOTTOM
' CHORD -BRACING 0 72' MAX.-O.C. REOUIREO ATTACH -WITH --,
' 2-16d NAILS. BRACING' -IS -NOT REOUIRED-IF A.RIGID_CEILING
IS-ATTACHED-DIRECTLY.TO-BOTTOM-CHORD. BRACING MATERIAL
TO BE SUPPLIED AND ATTACHED AT BOTH ENDS TO A SUITABLE
SUPPORT BY ERECTION CONTRACTOR.
Ell®
?14 1-
4X4
TC X -LOC L -R: 0.29 5.91 11.00 16.09 21.71
BC X-LOC.L-R: 0.29 7.60 14.40 21.71
(U1- BOTTOM CHORD CHECKED FOR 10 PSF LIVE LOAD.
ALL TOP CHORD SPLICES OCCURRING BETWEEN
PANEL POINTS ARE TO BE LOCATED AT APPROXIMATELY
1/4 OF PANEL LENGTH FROM PANEL POINT (WITHIN 12") AND
SHOULD NOT OCCUR IN PANELS NEXT TO A PANEL POINT SPLICE.
CONNECTOR PLATES DESIGNED FOR GREEN LUMBER PER NOS
TABLE 8.18.
2.5X4 (At) 1X3 1X3
4.001/"
2.5X4 3X4 2.5X4
11-0-0 _� 11-0-0
-0=0_OVER 2-SUPPORTS:�
R-7760 W- 3.50'
1
3LT.
TYP.—ALPINE SEON =.45568
0
TRUSSES REQUIRE RECTION CARE
0 0 .N= 0 0 **IMPORTANTN1i awLKNlEoee ERERsnoinlReDFoa AN.WARNING TH HANDLING, ERECTION AND
—
C=3 C� C= OEVIATION FROM THIS DESIGN OR THESE SPECIFICATIONS, OR ANY
BRACING. SEE HIB -91 BY NPT. SEE THIS DESIGN
C=3C=
C=3 C= FAILIWE 10 BUILD THE TRUSS IN CONFORMANCE- WITH OSTOB BY TPI
FOR$DOI11OL1L SPECIAL PERMANENT BRACING IE
C=1
p I. C= C ALSITJ CON/EC/DRB ARE MADE OF QOOA QALY. STEEL MEETING ASTM
OUIIEMENIS. UNLESS OTHERWISE INDICATED, ILP
C=3
G C G AAAO GR A EXCEPT AS NOTED. APPLY CONNECTORS ID EAC7 FACE OF
CHORD SHALL BE'�AIERALLY BRACED WIT" PROPER
E=)
AL P I N C TRUE ANO UNLESS OTHERWISE LOCATED ON THIS CESIGN POSITION
LV ATTACHED PLYW000 SHEATHING. BOTTOM CHORD
CONNECTORS PER DRAWINGS 170, ISO C ISDA-F. DESIGN STANDARDS
WITH PROPERLY A[TACHEO RIGID CEILING -- SEE
O
C
CdfOM W/APPLICABLE PROVISIONS OF Nag G TPI. AN ENGINEER'S
ALPINE -TECHNICAL UPDATE 1T/l/011 FOR PROPER
TRUSS SEAL ON THIS DRAWING APPLIES TO THE CON'OIENT,OEPICTED -HERE
DRYWALL APPLICA1IOH. FURNISH A COPY OF THIS
Q
IN ONLY. AND SHALL NOT BE RELIEO UPON IN ANY OWER WAY. I
C C=3 G G C W --TP i INUSS PLATE INSTITUTE. NOS -. 1991 NATIONAL 09516H
oESIGII TO THE IRU9S'ERECTION CONIRACTOR.
SPECIFICATION FOR 9000 CONSTRUCTION
s
CA
�a X93 J.I
DUTTE COUNTY
BUILDING DEPARTMENT
APP.R0VED
2.5X4 (A1)
4.00
V
.E c
R-7760 W- 3.50'
REV 15.6.5 SCALE
DESIGN CRIT: UBC REF R,
TC LL 16.0 PSF DATE I
TC 'OL 10.0 PSF ORWG M
BC OL (U) 5.0 PSF CA -ENG'
TOT . LO , ., 31.0 PSF 0/A LEN
DUR.FAC. 1.25 IPITCH
SPACING 24.0, STYPE"`(
- 0.2500
27--5586
6/30/92
'R427 92182001
c:c-v-v
4:OL.12
MN--
0
N
0
e
c�
z
z
I
03/19/93 09:54 $ 916 534 0908 Barnhart=Brown
P.02
56�5- Il�7-77,4 <f , 5jq
/7H 114-CAoIAMA:
-
h= 2. z7 -E
Wil/ F;• c.13s.
s
OF CA1�FO��
o
sem. 4,
; I
93 - 32 Z -
BUTTE COUNTY
;UILDING'DEPARTMENT
APPROVED
i
oic
SC�-�G/J3� IiES�a `1YJ D.C.
i
�•t
M CSG 7
sueJECr:.6; :s= t4 ) E,,,p t -h, A-,14.> Ire t,c..lt��
CLIENTS NAME. _ JOB NO.
ytit t�/.J COOK �MSOCIATES
JOB DESCRIPTION eluolNSERINO CONSULTANTS
• ooeo PARK .VENUE DATE
OROVILLe. CAL1PO~^ eeSee
— - - - - a .. . _
J EZT 114& 24 "e c
6-6 X /10 /10 t"WF U012L 10 4CO I %+Q.0
I
II •I Z LCL EAQ
I Przc'i c CIT r a Nr,.j
d
A
-
pca.�
4,?AU E ---
GQIs
Nt PT S 5
3 CL OAA
I i ClJ�p>L f�wTi:Gf
P/Q0W/joF eame-
y,G0LL (J�V"4. 7-11E ZowL OF
SL/�r3 / S fv2Eo �2 j DAYS
L� /D
2 9 4 Z'D A
�A4.
BUTTE COUNTY
BUILDING DEPARTMENT
148294
SUBJECT :.
sT, t�9,/j 0 i,Jc,If
li�s�c L
CLIENTS NAME
Jim 732
�
JOB NO.
/.��/-r
�-/U�9✓If
rte- ASSOCIATES
JOB DESCRIPTIO
ENGINEERING CONSULTANTS
• 0080 DARK AVENUE
DATE
OROVILLE. CALIFORNIA 8608E
SHEET OF SHEETS
SPEC/FICA TIONS
1: CONCRETE - f c=2000 PSI' (9 26 DAYS
2. REINFORCING - ASTM A615, GRADE 40 MIN
3. LAP SPLICES - 20" MIN
2. F0077NGS SHALL BE EXCA VA TED INTO FIRM, UNDISTURBED SOIL TO DEPTH D
FLOORS HOR/Z BARS VER T BARS T B D
ONE #4@13"0. C. - #4(922 "0. C. 6" 12" 12"
TWO #4®JO"O. C. #4916"0. C. 8" 15" 18"
'FLOORS REFERS TO NUMBER OF FLOORS PER UBC 4 =10" Ad
TABLE 29—A, WHERE GARAGE SLAB IS FIRST FLOOR. 6"
_ I MAX
(4 ® 48" O. L
,X6-10/10 W
0 SLAB CIL
3 1/2
7LAB
COMPA C 1
BA C)
UND/S7Z
IN F0077NG
B
077 -'ER HEIGHTS OR CONDI T70NS REQUIRE ENGINEERING
F CURB
P" OR
F.
FOR
AND UN 77L SLAB HAS
CURED SEVEN DAYS
RESIDENTIAL GARAGE FOUNDA 1-70N WALL REV Qi 7r
scAce J/4 :► =o' DA TE:• 4/92
BUTTE COUNTY BUILDING DEPARTMENT DWG. WALLZR 57D 12.5
<V
tj�.
Ix
I.AL
ix
-:57
-SUBJECT.
CLIENTS NAMV,
ATES"
JOB oucwrp-f-law—=NMULTAMY DATE
VANK Avoodw:
OF -SHEETS
I MLIST be
This, set of plans and s0btlficat'O'ls M
kept on the iob at all, times and it is unlav,,I'Iui to
' j thout
make ani q�p-
,,iges or alterations on same ijvit
written pe.,,j-,j:ssjon from thb, Departmen! oft Public
Works, Cou-,IVY Of BJ"te-
I
PAS C- i
PLOT PLAN
NOTTO aCALE
t-qL,,01 0
n of structures &
equipment shall be as show
clearQf all qserent
g
�-o� �° C
123
ce.
-NOTE:—AII'Materials & Workmanship Shall Be in
Accordance vvith RecognZ
! ed Good Practices and
L
of a _cribea.far'lhe SpaCftd use in the
..qyality pr ft
Uniform Bu ' ilding, Pluh)bing & Mechanical Codes -and
-National Eie.cfiric4l Ccda–
S
APPROVED,! -
!Butte ,, Count
Eriviro'6nrnentai IHea1.th
re
ro
3,t z. -
BUTTE COUNTf
BUILDING DEPARTMEW
A P P R0_ VE ���
2-2-6 _e? 3; U
Ap 130 —1
LOT
SI V4 13y'vit'll-
GaDVILLE, CA.
A �u
4.
-a
FLOOR Fouvibarlosu PLA -4
Ilk
I
, �Tp
8
exterior outlets par Art. 2,10-NVO, A; AM0400068 and YeaMmon per CIL 82, Ukto.
e
ox
�tX
, \
IN-,
22'
P
r��4 kIf 3�310
K 4#
-V iu
Ss D'u XL
A L L- ( 0 A �LL 5 - �7_x _Y
TV-
jJ) PU ELECTR-1 CA L 54ALL mmar 6r
V CLOff-'A'
1,' Wstip
VT-#+CrjNrr eopJUErEl 51PIALL OE T12CAMD'09- MDWOO&i
'51blIV6 5*^Lbevk;0A5Ds0rc Ty Pc ti v fta pm iz 51v cc -f
A -LL FA*MU495 S14AL&. MG9r L&,fj C, �1-*&
(!D F-LIEGMCAL 5#P16,L
BC -
TA D
cp.r&D
r
1/2' X I& chor boft
@ WO.C. max.,and within
12" of joints.
garage, ah
QuUat's-par, ArL 21" ESQ,
MA
("00 f, �J �
3j'i SPECIAL ROOF COVER
IN REQUIRED.
ex I V"
WIq
Cow
UL
ID
zv fuz-F L
,*PJ
Rag 5L 44'
@ M 4 Y, Pf*V
sm UA/cl TrS T%(Pr
colucaae-,-L-f� nAllu. IV' kN
4
c1zQ5'_':.5r-_CTJ0r%) 7'
FUER 151-Af W'*Dr-11JC PIE! D-ErA L
vor 10 5cAt,E,:"
It cf�
41/x?.1/?_" PLYWVDD aMFOTIM6 A.S16
+fv,
N POW 51
ON
_,VA?0K win P/c,
PA.
Specs
Z -4 q Tieg-a-TE P 5 1 L L i j
eo.v(_aCTF_ -5LA3 X_ jj -1
clo I
Mi c 2.
4
Provuie aMrOved ft at au @*Gaklr
BUTTE MUNTY
13UILDING DEPAATMENT
A RP R 0 V E D
'J
i c
Fu: TIM. V2160-ar
acM&rr. T_b14
BY: cil-A
s".17 59303Z
C��
Al
TS
C��