Loading...
HomeMy WebLinkAbout079-340-015AP - I/ HILTON SIMMONS 1158 Mt. Ida Rd. , lot 1, roe 75 Permit#• 552-75B,P,E,M(new SF) •03f�-y�9_g}_5-., 93-755 B, E YO "��S ' soliz, al f �� s 1 ;,1158 PTT IDA, OROVILLE CONTR:. POLLY POOLS s p _q3 ,. SWIP'MING POOL 946 6�9 03-0167. FRIEDMAN, ROBERT AND CIND 1158 MT IDA, OROVILLE INALE - CONT: SUN POWER • Z -I - 3 ROOF MOUNT SOLAR31 ,i i i • 9 n• i 'CrbI I M r el- - .yr NOTES PERMIT NO. RESIDENTIAL 036-670-015 03-0167 FRIEDMAN, ROBERT AND CINDY 1158 MT IDA, OROVILLE y CONT: SUN POWER ROOF MOUNT SOLAR SPECIAL CONDITIONS CHECKED BY SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER JOB FINALED D Signatur J=OK 0 = Not OK . = Not Readyable MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s Zoning Requirements -Setbacks -Easements 1. Zoning Requirements -Setbacks -Easements 3. 2. Soils; Special MH Support Sketch ' Wood Awn.; Posts- Beams- Rftrs-Connectors Shthg-Frg-Bracing 3. Sewer; Location -Test -Fall -C/O -Concrete 6. 4. Water; Location -Test -Easement Needed (Sketch) Electric 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap;-/ /" L 'ft. / P Nat. or/ /" L "ft./ P LPG Card B-1 Date Card B-1 7. Well Clearance & Disconnect Card B-1 Date Card B-1 8. Utility Clearance 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability Date 3. Card B-1 Date Card B-1 Date 4. Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s Elec.; Pool Lighting; 15 Volts-GFI 1. Zoning Requirements -Setbacks -Easements 6. 2. Footings; Size -Spacing -Marriage Line 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 3. Gas; MH Test -Demand -Valve -Connector Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures-Panelboards-Ins. to Main Conduit 4. Electricity; MH Test -Crossovers -Breakers -Clearances Health Department Approval 5. Drain; MH Test -Fall -Flex Connector Plumb.; Cir. Test -Water Supply Test 6. Water; MH Test -Regulator -Connector Light Niche 7. Water and Sewer. Connected -C/O to Grade -HD Approval Enclosure; Fencing -Alarms 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. Card B-1 Date Card B-1 10. Exits; Insp.-Sketch . Card B-1 Date Card B-1 11. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PERMANENT END SYSTEM (ONLY) 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Blocking 4. Gas; MH Test -Demand -Valve 5. Electricity; MH Test 6. Water; MH Test 7. Water and Sewer Connected 8. Gas and Electricity Tagged 9. Exits 10. License Decals 11. Verifv #'s with Office Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn,; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elea; Receptacles and Lighting, Distance -GF] 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures-Panelboards-Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J=OK 0 = NotOK Applicable = Not Applicable RESIDENTIAL (Single & Duplex) . = Not Ready Date UNDERFLOOR (Plans) OK except #'s 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/0 -Sewer Test 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Criooies Date 15. Access & Ventilation r 16. Insulation 48. Cling. Joist-Rftr. Ties- Purl in -Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 23. Fire Sprinkler; Test 60. Shear Walls; Nailing -Bolts Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s Date 24. Fixture & Transformer Clearance -Ins. Protection Date 25. Elec. Receptacles Spacing -Lights & Switches at Doors Date 26. Size Boxes & No. of Conductors Stapled 27. Romex Installed Close to Edge of Studs & C.J. 28. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 29. 2 Appliance Circuits in Kitchen & Conductor Size GFI 30. Subfeed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al 31. Range Circle/ /ga Cu or AI -Oven Circ. / /ga Cu or Al Insulated Neutral O Yes 0 No 32. Service -Riser Conductors & Ground Main Disconnect 33. Equip. Clearances Panels-Motors-Mech. Equip. 34. Clothes Closet Light -Shower Light -Spa Light oke Detector 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 36. A.C. Ducts Insulation & Support 37. Vent Fan, Exhaust above insulation 38. Condensate Drain & Overflow, Size & Grade 39. Furnace -Vent Access -Comb. Ait-Return Air Vent 115 Outlet 40. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s 41. Sills Proper Materials & Anchors 42. Walls Studs -Nailing Spacing & Braces -Plates -Sound 43. Bearing Walls over Girders & Floor Nailing 44. Draft Stop in Walls (rat proof) 45. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 46. Headers & Beams -Size & Bearing Date FRAMIN ntinued) r 47. angers-Pe@Woap@,Anchors-Connectors 48. Cling. Joist-Rftr. Ties- Purl in -Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 50. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Property Line Firewall & Openings 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 56. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 57. Siding -Nailing Veneer 58. Stucco Mesh -Drip Screed -Fd. Vents-Underfir. Access 59. Glazing Area -Glass Protection -Skylights -Plastic 60. Shear Walls; Nailing -Bolts 61. Brace Interior/Exterior Wall Panels 62. Insulation -Walls -Ceilings 63. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 64. Ext. Steps -Door & Sidelight Protection -Landings 65. Smoke Detector 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 67. Bedroom Exiting 68. G.F.I. & Bath Fixtures & Tub Access -Spa 69. Elec. Trim & Subpanel, Breaker Sizes & Labels 70. Stairs & Rails 71. Fireplace or Stove, Clearance -Hearth 72. Elec. Outlets at Wood Panel, Int. & Ext. 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance 74. Elec. Outlets & Receptacles at Kit. Counter 75. Garage Fire Door; Swing -Landing -Closure 76. A.C. Duct in Garage -Damper 77. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 78. Plb.; Elec. & Mech. Equip. Listed for Location 79. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 80. Insulation -Foam -Looked in Attic 81. Guard Rails & Deck Construction -Post Caps 82. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes _ 83. Following Instld./Drive 0 Yes O No/Walks O Yes 0 No/Planters D Yes O No 84. Stucco Brown -Finish 85. A.C. Unit Disconnect, Electrical -Plumbing 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 87. Water Well, Disconnect, Electrical, Plumbing 88. Exterior Elec. Trim, G.F.I. Receptacle -Underground 89. Ventilation Throughout House 90. Glass Protection 91. Corrections from Previous Inspections 92. Gas Test -Meters Tagged, Gas -Electric 93. Water & Sewer Connected -C/O to Grade -HD Approval 94. Energy Compliance Certificate -Other Certificates 95. Address Posted 96. Fire Sprinkler Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive Oroville, California 95965 •Telephone (530) 538-7541 PERMIT No. (Rev.12/96) APPLICATION AND PERMIT �3-0�h� ASSESSOR PARC0.NUMBER 030-o70=0i5 ZONING , BUILDING PERMIT OWNER Fredman Robert TELEPHONE ' SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS CONTRACTOR'S NAME Sun - TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filin Fee '$ 2Q•l)� Permit Fee $ 54.00 ARCHRECT OR ENGINEERS MAILING ADDRESS Plan Checkin Fee $ BUILDING ADDRESS zz � Energy Plan Checking Fee $ $ PERMIT FEE S 't LAT NO. SUBDNIS IONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other sPEclrY Solar or heat um water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK New ❑ Add'Rion ❑ Remodel ❑ Ufilities ❑ Installation ❑ Other ❑ Describe Work: �nnf Mnttnt Snlar Gas i in stem 1 - 5 outlets 15.00 Buildin sewer 15.00 Mobile Home S G W @20.00 PERMIT FEE S ELECTRICAL PERMIT Filing Fee 20.00 Main Service 2ooAoa�ss 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license ' I rc nd effect. � License Class — Lic. No.� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages astheir sole compensation, will do the work, and the sVucture is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ I am exempt under Sec. ,Business and Professions Code for this reason Main Service zooA To ,000A 46.00 NEW CONST. DWELLING OCCUP. OR ADDNS. ( a acc. eLos. SO 3.5Q�: NEW CONST. MULTI -OUTLET NON•RESID. @7.5� �N'ER APPARATUS 8 SINGLE OUTLET CIR. Ex. Occu OUTLET OR FDTTURES ens o':s'�o FlXED APPINS. OR Ex. Occu ouTLtTs REslo. EA S.00 Tem orar Service 23.00 Mobile Home Facilities 20.00 Misc. Wirin 23.00 PERMIT FEE S WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My work men re c rier d poli u rare: Carrier Policy Number (fhe above sections need not a completed 'rf the permit is or work of a valuation of one hundred dollars ($100) or less.) ❑ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that'rf I should become subject to the workers' compensation p 'sions of section 3700 of the Labor Code, I shall forth th omply with,th a pr visions. X � ate � r�� __ Sig re of pplica t - ❑ Own r ❑ ConVactor�Agent An OSHA permit is required for excavations over 5'0" ep end demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Filing Fee 20.00 Nesting Coolin Hood 6.50 Ventilation PERMIT FEE S Mobile Home Installation Fee $ Energy Inspection Fee $ occ coNST. TYPE TOTAL FEE HAZ. D. FEES IMP FLOOD CDF D ISS This permit is hereby issued under the of the B e County Code and/or indica d or w ich fees have By ��� PERMIT EXPIRES ON � applicable provisions Resolutions to do work been paid. / Z,?J. �3 ate 4i Dete ReceiptNo. WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 ;-� PERMIT APPLICATION DATA SHEET / OWNER: ' l /\ ) ��' t G`' i� ASSESSOR PARCEL NUMBER V - P V • y 5 Proposed Building Use: �� l C;�N Y Counter Technician: 1 Date: ) � D1. 63 Items required in order to apply for a permit. All boxes MUST be checked OR marked NA in order to apply. ❑ L. Plot plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 4. Engineered truss details and layouts in duplicate. No faxes! ❑ 5. Energy compliance design and supporting documentation in duplicate. ❑ 6. Manufactured homes: (A) Data sheets and installation instructions, (B) Marriage line information, (C) Floor Plan, (D) Tie down or foundation plans, all in duplicate. ❑ 7. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicate, (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. Items required for initial plan review. If checked items have not been received, plan review cannot proceed. The permit will be indexed and returned to the plan review line-up when required items are received. ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate. ❑ 9. Plot plan and business license approval from the City of Biggs. ❑ 10. Letter of intent for non-residential buildings. ❑ 11. Detached Accessory Building Form filled out by the owner. ❑ 12. Hazardous Material Form. ❑ 13. Other Remaining items needed to issue the permit. (May require additional plan review upon receipt of the following items.) ❑ 14. Fees as shown on the attached Schedule of Fees Due Sheet. ❑ 15. Statement of Intent for Non -heated and A/C Buildings. ❑ 16. Sanitation and plot plan approval from the Environmental Health Department in ❑ 17. City of Chico Plumbing permit. ❑ 18. California Department of Forestry plan approval ❑ paid. ❑ 19. Planning approval for (A) Use: (B)Parking: (C) Parcel Check: ❑ 20. Contact Land Development about ❑ Improvements, ❑ Drainage. ❑ 21. Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). ❑ 22. Pre -Inspection for required. ❑ 23. Contractor's license information. (Number, Name Style, Classification). ❑ 24. Worker's Compensation Carrier and Policy Number. ❑ 25. Owner -Builder Verification ( ❑ Given to owner, ❑ Mailed to owner). ❑ 26. Letter of Signature authorization. ❑ 27. Recorded copy of Agricultural Acknowledgment Statement. ❑ 28. Manufactured home utility clearance. ❑ 29. Existing violations and/or expired its. 1 0. ❑ 30. ❑ Grant De d �lv� itle/Stat ent of Facts, Letter fro�egal Own r Check to H.C.D. $ 31. Other: Y en issued Telephone and ho for pickup. I have been informed of the above items and requirements for obtaining a building permit. Applicant: Date: EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after date of application. In order to renew action on an application after expiration, a new application, plans and fees will be required. REQUEST FOR FEE REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made within two years from the date of fee payment on permits not issued, and two years from the date of permit issuance for permits issued; however, on issued permits refunds can only be made if no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. Original -Applicant dG 1741 lis ted or grid � - r r � �• -t ` _ s nterachve K- _ ►.=year _ _ - omprehenswe varranty',t � � " ,ugged.NfMA !X stainless steel "=Yt L Uldool T - K nclosure' Dint.; comm unicaiionsPiny collect►on� r. V%F ' ��?��j 1 "Is SpecThcations Inver{Cf Tedmolow AC Input YJWW AC Input &Vpency DC&PA Vahar Peck Power liackng *huge Mireaurn DC Input Vamge Maxim. AC Power Output Current THD Power Fodor Peak tnerter Oft iency PV start Vahage Mmdn= AC Currerd Maximum DC Current DC W -V Ripple Power Consumption Ambient Temperature. Enclosure size Wegd Real sine_wave, current source, high 6quency PWM 211-264 (240 V AC) or 183-2291208 V AC) 59.350-60.6 (60 HzL 50 Hz also 25000 V DC 234-55D V DC (at 24D V AC) 207-256 V dependent on available line voKW . 2500 W (240 V AQ, 2200 W (208 V AC) Less than 4% Unity 93%94.4% Convection cooling (no 6) 300 Vac 10.4 A 13A Less than 5% 0 W nighttime, < 0.25 W sWd)y -25 *C... +60'C NEMA U stainless steel 434 W x 295 H x 214 D mm 32 kg Certifications United Stades: UL 1741, E210376, UL 1998, IEEE 519, IEEE 929 ANSI C62.41 Cl & C3, FCC part 15 A&B International: DIN E450082 Part 1, 61000-32, 50081, 50014, 600055 Part 2, 55011 Gioup 1 Class B, 50178, 60146 Part 1-1 DMUITED BY a PANEL EARTH CRaUND Sunny Ba Is unsurpassed reliability and efficiency is the result of SMA's manukx- luring philosophy that combines simple lesign with robust exertion. %Ws slate -of - the -art maximum power point tracking per%rmance results in greater real-world energy capture than any other grid -bed Pv inverler. Sunny Bogy's safety and reliability record is also exception al due, in part, to the inverter's redundant grid monitoring and buih-in ground fault detection and intenvption protection. The inverter's CBT power stage genernies a nearlyperled sine wave with the lowest harmonic distortion in the industry and meets new ultra -strict KC EMC standards. SMA's unique String Inverter tech- nology makes future system expansion simple. Sunny Boy's option- al power line comer communication capability allows for extensive data acquisition from one or many inverters with no arcUhonol wiring. [Optional powerline modem required.) Other communica- tion options are available to satisfy almost any application. SMA Americo , Inc., 20830 Red Dog Road, Grass Valley, CA 95945 Phone 530-273-4895•Fox 530-274-727) www.SMA-AMERICA.com • email: info@SMA-AMERICA.com SMA Regelsysteme GmbH • Hannoversche Strasse 1-5, D-34266 Niestetal Tel. (+49) 5 61 95 22 - 0 • Fax (+49) 5 60 95 22 - 100 www.SMA.de - email: info@SMA.de Advanced System Technology for the Successful Photovoltaic Future rage 1 or 4 AS T Q O PCS YYE R ` FACS Em ment ',O site Mao. s Search " Contact_Us 'R PRODUCTS & SO1.U'CIOI•IS INv Wt1pR IN.K*NtAn0N A4,`M '•2PO%li IZ ,.�rL1RN AB(Arr SOI..AR pt)'% M Cells N40rles ReWentialSyaqrw Com Sy$1i M powe;i 1LIW UWUWWSYVCM Advarimcl ProdUM Where You Are: AP-110/AP-120 Module Specifications Home Products & Solutions Ke Features Y tModules LAP-110/AP-120 • Over 6.5 amps of charging current in full sunlight Leam Mae: Download Datasheels. • Ideal for AC and DC installations up to -110 600 Vdc (nominal). AP -120 APex7m Technology • Mather rent junction box for easy Module Inquiry Form and safe field install"on. Glossary .Frequently Asked • pcel low -loss bypass diodes for superior Questions protection and minimum power loss when partially shaded. Related links: Builders and Developers • 100% factory inspected peeled to ensure quality Residential Systems and electrical performance. Off -grid homes Become A Dealer , . Heavy duty anodized aluminum frame provides strength and convenient mounting access. • Overall dimensions and mounting hole pattern conform to industry standards. • Certified to IEC -61215, the highest industrystandard. • Both are UL listed. The AP -120 is also TW qualified. • 20 year warranty. http://www.astropowe.r.com/apl 106ap 12 06. htrn 10/1/2002 «rjv v va T Download AP -110 Tech Sheet in pdf format Download.AP-120 Tech Sheet in _pdf format C -E' _ _ 7 O Typical Electrical Parameters Standard Test Conditions: Irradiance = 1000 w/m2; Cell Temperature = 25oC; Solar Spectral Irradiance per ASTM E892 (1.5 air mass) IFAP410 AP -120 IFP;; -Power (Wp) 110 watts F120watts Open Circuit Voltage (Voc) 20.7 volts F21.0 volts Maximum Power Voltage (Vmp) L6.7'volts 16.9 volts Short Circuit Current.(Isc)amps 7.5 7.7 amps Maximum Power Current (Imp) 6.6 amps 7.1 amps ;1 "'-1800 Wlni'. 25 deg. Maximum Series Fuse 15 amps 15 amps http://www.astropower.com/apl 106ap1206.htm 10/1/2002 a � v ;1 "'-1800 Wlni'. 25 deg. i ... i�0 YKIn► ; 69 deg. T..,� " 900 WW. 46 deg. Ton, 1 http://www.astropower.com/apl 106ap1206.htm 10/1/2002 - --Z,- -- v - Typical Electrical/Mechanical Parameters 45 OC Nominal Operating Cell Temperature (Irradiance = 800 w/m2; Ambient (NOCT) P~ t t Wind Speed =1 m/s) Short Circuit Current Temperature 1A1 —" 1 N Vat'. as ft T", - loon W. " Matt. �S dtg T.. : 1 1 -0.08 VJoC Typical Electrical/Mechanical Parameters 45 OC Nominal Operating Cell Temperature (Irradiance = 800 w/m2; Ambient (NOCT) Temperature = 20oC; Wind Speed =1 m/s) Short Circuit Current Temperature Coefficient. +0.6 mAJoC Open Circuit Voltage Temperature -0.08 VJoC Coefficient Typical Fill Factor 71 % (AP -110) 74% (AP -120) High Voltage Standoff Potential 2200 volts Ground Continuity of Module Frame F<,;; 501bs1ft2 (125 mph equivalent) Wert (Wind) Bearing Potential 2400 N/m2 (200 kph equivalent) 1" at 50 mph Hailstone Impact Resistance 24mm at 80 kph 26.1 lbs Weight ' 11.9 kg 1[58-1 x 26.0 x 1.4 inches hftp://www.asftopower.com/apl 106ap 1206. htm 10/1/2002 Dimensions Physical Specifications -771.- 24.3 k 1476 x 660 x 35 mm MAN" u TA it. 29.0 iL AMP -110 Tech Sheet in pdf format M Wer! AP -120 Tech Sheet in. pdf format AstroPower, Inc. Solar Park Newark, Delaware 19716-2000 USA Tel: 302 -366 -OW Fax: 302-368- 6474 Copyright 0 2002 AstroPower Inc. All rights reserved. hftp://www.astropower.com/apl 106ap1206.httn 10/1/2002 3 MWI V=OK O=Not OK - = Not Applicable Not Ready MOBILE HOMES ' = -Date/initials MOBILE HOME UTILITIES (Pians) OK except #'a 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Locatlon-Teat-Fell-C/O Concrete 4. Water; Location -Test -Easement Needed (Sketch) S. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 6. Gas; Location -Teat -Wrap: / /"L"ft. / /"Net. or/ P'L"ft./ /"LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date/Initials MOBILE HOME INSTALLATION (Plans) OK except #'a 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3.. Gas; MH Test-Demand-Valve—Connector 4. Electricity; MH Test-Crosaovers-Breakers-Clearances 5. Drain; MH Teat -Fell -Flex Connector 8. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy MISCELLANEOUS Date/Initial DECKS, COVERS, CARPORTS, OARAOES, (Plana)OK except #'a 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftre.-Connectors Shthg: Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 8. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftre-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date/Initials POO (Plena) OK except #'a Setbacks -Easements 6ils Compaction -Structure Stability ool Structure; Steel -Connections -Thickness -'r-Elec.; Receptacles and Lighting, Distances-GFI 5!SIec ; Pool Lighting; 15 volts-GFI _A!,Elec.;Isclosures; Conduit Entries -Terminals -Listed 4-'Efec.; Bonding; Metal w/5' -Circulating Equip -Heater (T -S4 " Elec.: Groundina; EauiD. w/5' irculatina Eau of Lahta. !-f.(j_•S; /5->L-3oxes-Enclosures-Panelboards-Ins. to Mein in 9. He Ith Department Approval 11r—Plumb.; Cir. Test -Water Supply Test V=OK O = Not OK - = Not Applicable RESIDENTIAL = Not Ready Date/Initials UNDERFLOOR (Plans) OK except S's 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Mein; Soils-Elec. Grnd.-/ P' Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd:/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16, Insulation Date/Initials PLUMBING (Permit) OK except U'a 16. Water Htr.; Vent -Access -Combustion Air -Baffle 17. Water Pipe; Test & Anchor -Nail Protection 18. D.W.V.; Teat -Fittings & Anchor -Nati Protection 19. Shower Pan; Test, First Floor -Tub Access 20. Test Tub & Shower, Second Floor -Tub Access 21. Gas Pipe; Size & Anchors Date/initials ELECTRICAL (Permit) OK except M's 22. Fixture & Transformer Clearance -Ina. Protection 23. Elec. Receptacles Spacing -Lights & Switches at Doors 24. Size Boxes & No. of Conductors -Stapled 25. Romex Installed Close to Edge of Studs & C.J. 26. Equip. Ground made up w/Meth. Fastners-Bond Gas & Water 27. 2 Appliance Circuts in Kitchen & Conductor Size/GFI 28. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al. Insulated Neutral ❑ Yea ❑ No 30. Service -Riser Conductors & Ground -Main Disconnect 31. Equip. Clearances Panels -Motors -Mach. Equip. 32. Clothes Closet Light -Shower Light -Spa Light 33. Smoke Detector Date/Initials MECHANICAL (Permit) OK except #'a 34. A.C. Ducts Insulation & Support 35. Vent Fan; Exhaust above Insulation 36. Condensate Drain & Overflow; Size & Grade 37. Furnance-Vent; Access -Comb. Air -Return Air Vent -115 outlet 38. Attic Access & Platform if Furnance in Attic Date/Initials FRAMING (Plans) OK except k's 39. Sils, Proper Material & Anchors 40. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound 41. Bearing Wells over Girders & Floor Nailing 42. Draft Stop in Walls (rat proof) 43. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 44. Headers & Beam -Size & Bearing (Single & Duplex) Date/Initials FRAMING (Continued) 45. Hangers -Post Caps -Anchors -Connectors 46. Cing. Joist-Rftr. ties-Purlin-roof Brac-Trues-Shthng.-Rfng. 47. Fireplace Ties or Type A Flue -Fireplace Throat clearance 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 50. Garage Fire Protection Framing 51. Property Line Firewall & Openings 52. Ext. Doors -One 3' -Check Garage -3rd Story, 2 Exits 53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 54. plywood on Roof Overhang -Attic Vents -Rafter Outriggere 55. Siding -Nailing Veneer 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 57. Glazing Area -Glass Protection -Skylights -Plastic 58. Shear Wells; Nailing -Bolts 59. Insulation -Walls -Ceilings 60. Infiltration -Walls -Windows Date/Initials FINAL (Plans) OK except N's 61. Ext. Steps -Door & Sidelight Protectlon-Landings 62. Smoke Detector 63. Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor -Ducts -Mach. Protection 64. Bedroom Exiting 65. G.F.I. & Bath Fixtures & Tub Access -Spa 66. Elec. Trim & Subpanel; Breaker Sizes & Labels 67. Stairs & Rails 68. Fireplace or Stove; Clearances -Hearth 69. Elec. Outlets at Wood Panel; Int. & Ext. 70. Kit.Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance 71. Elec. Outlets & Receptacles at Kit. Counter 72. Garage Fire Door, Swing -Landing -Closer 73. A.C. Duct in Garage -Damper 74. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage; Above Floor -Mach. Protection 75. Plb., Elec. & Mach. Equip. Listed for Location 76. Elec. Receptacles in Garage; (G.F.I.)-Romex Protection 77. Insulation -Foam -Looked in Attic ❑ Yes 78. Guard Rails & Deck Construction -Post Caps 79. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 80. Following instld.; Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑ Yes ❑ No 81. Stucco; Brown -Finish 82. A.C. Unit; Disconnect, Electrical, Plumbing 83. Vents Above Roof; Plbg: Appliance -Fireplace: Clearance to Openings 84. Water Well; Disconnect, Electrical, Plumbing 85. Exterior Elec. Trim; G.F.I. Receptacle -Underground 86. Ventilation Throughout House 87. Glass Protection 88. Corrections from Previous Inspections 89. Gas Test -Meters Tagged; Gas -Electric 90. Water & Sewer Connected -C/O to Grade -HD Approval 91. Energy Compliance Certificate -Other Certificates Comments at Final: COUNTY OF BUTTE -DEPARTMENT OF PUBLIC WORKgr 7 County Center Drive - Orovi;le; California 95965 - Telephone: 916/538-t,11 16/538- 541 APPLICATION AND PERMIT PERMIT NO. 9 1 ASSESSOR PARCEL NUMBER 036-670-015 ZONING AR BUILDING PERMIT OWNER SOLIZ TELEPHONEAL SQ. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 1158 MT IDA RD., OROVILLE CA 95966 CONTR 13,500 CONTRACTOR'S NAME POLLY S TELEPHONE 673-6131 CONTRACTOR'S MAILING ADDRESS 377 HUTCHINSON RD., YUBA CITY CA 95993 Fireplace CONSTRUCTION LENDER NONE UNKNOWN Total Valuation Is LENDER'S MAILING ADDRESS Filing Fee $ 15,00 Permit Fee $ 127.50 ARCHITECT OR ENGINEER NQNF LICENSE NO. Plan Checking Fee $ 20.00 ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ Penalty $ BUILDING ADDRESS OROVILLE Permit fee $ 162.50 PLUMBING PERMIT Filing Fee 15.00 Each Trap 5.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 7.00 Each qas water heater or vent 7.00 USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome❑ Other POOL SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 15.00 Mobile Home S I G I W 615.00 TYPE OF WORK New r Addition ❑ Remodel ❑ Utilities ❑ Installation[] Other ❑ Describe work: MASTER #91-504 Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 15.00 Main service 200A OR LESS 18.50 CONTRACTORS LICENSE LAW I declare nder penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force a d effect. License No.& 53 613 33 q— Classification e _ S FlI, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason Main service 200ATO1000A) 37.50 NEW CONST. / DWELLING OCCUP.tk\ OR ADDNS. \ ACC. SLOGS. I 3.64sq.ft. NEW CONSTR U TI -OUTLET NON.RESID BRANCH CIRC ITS 5 00 POWER APPARATUS \ (SINGLE OUTLET cIe R. / Ex. Occup( OUTLETS OR FIXTURES 20 76 FIXED APPLNS. OR Ex. Occup. OUTLETS (RESID.) EA.) 3.00 Temporary service 15.00 Mobile Home Facilities 15.00 Misc. Wiring -15.00 15.00 Permit Fee $ 30.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. have placed on file with the County of Butte Building Department u/ a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT FiIingFee 15.00 Heating Cooling Hood 6.50 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against allalliabilities, judgments, costs, and expenses which may in any way accrue g y in c nsequence he granting of this permit. q 2 X - Date �— Z 4 - ` / ❑ Contractor P Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee S Energy Inspection Fee $ occ CONST TYPE TOTAL FEE $ 192.50 HAz DFEES =— IMP FLOOD- COF PARC .� PD HD IS UE This permit is hereby issued under the applicable provi- sions of the B C un ode and/or resolutions to do or which fees have been paid. work Indic eXZR IOF PUBLIC WORKS By ate 33/ y� PER EXPIRES Date 3/ Receipt No. 135895 WHITE-O.P.W., YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT �r„ , ti �i�+%'ri�'ty-,,` x�`�ei�'tf•�,.��ry-�''U{"`�v.-.�..�nAy`�l.�r"7.y✓�w'�':r..�-f��')'��„� %pnr�•iy��?'rN,_�„�yy�.�,5- '.��'1i�">hvx(+�'w�,. �1{n�l�`��r.�y.,..:�.-�4.,r-:. a" COUNTY OF BUTTE - DEPARTMEfJT_ ,�,QEVELOPMENTSERVICEDBUI DINGDIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA95965 - TELEPHONE (916) 538-7541 �y a - PERMIT APPLIcATION DATA SHEET OWNER _ Proposed Bu Use s A. P. No. 031 Building Inspector At Date At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECENED BY 1. All items have been submitted . ........................................ 2. Plot plans, 3/4 sets, signed by preparer of plans . .......................... 3_ Complete plans, 3/4 sets, signed by preparer of plans . ..................... . 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............ . 5.. Hazardous Material Form . .............................................. 6. Energy Design Compliance and supporting documentation . .................. 7. Statement of Intent for Non -Heated and A/C Buildings . ...................... 8. Engineered truss details and layout in duplicate (required prior to plan check). .... 9. Mobilehome data and manufacturer's installation instructions, 2 sets. ........... 10. Fees of $......................................... 11. Impact fees as shown on attached schedule . .............................. . 12. California Department of Forestry plan approval/fees. ....................... . 13. Flood elevation letter (100 year floo20A by California Engineer. . . va 14. Sanitation and plot plan approl- uQHealth Department . ............ 15. City of Chico plumbing permit ..... . 16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: 18. Contact Land Development about (A) Improvements (B) Drainage. ........... 19 Driveway permit (construction approval required prior to occupancy) 20. Pre -inspection for Prea"spe on req"e - required. .. to B�;,ding Inspector (Date) 21. Contractor's license information. (No., Name Style, Classification) . .............. 22. Certificate of Workmans Compensation Insurance . .......................... 23. Owner -Builder Verification (Given to owner , Mail to owner _). .......... . 24. Recorded copy of Agricultural Acknowledgement Statement . .................. 25. Letter of signature authorization . ........................................ 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . 27. Letter of intent on building use . ......................................... 28. Mobilehome utility clearance . ......................................... . 29. Documentation of legal access . ..................... :................... 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... 31. Existing violations/expired permits . ....................................... 32. Plan check list . ..................................................... 33. 34. When ou issue the permit, process as follows: Mail to owner. Mail to contractor. Telephone and hold for pickup at 0Ae2 office. Deliver with inspector. Other Parcel Creation Acreage Applicant Date 3� Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Contractor, designer, owner, was advised of above requijed data by _ phone _ mail �-Counter by _ Date Plans checked by �'L Date 311 7 Plans approved by (,�/L L Date Sets of plans on hold in File cabinet AP folder L Copy - Department of Public Works „r PERMIT NO. 5 52-7 5B. P. E. M n fi E M MH UTIL. ',PERMIT NO. 4 PERMIT EXPIRES c:2 ,OWNER Hilton Simmons `f,'C0NTR. 'LOCATION (A.P. 36-67.;.15 ) 1158 Pelt. Ida Rd., lot 1, Oroville 1: i I 0 5 r. J, ti y A i N Temp. Power Pole Called PG&E 9 T.ernprElec. Serv. Called PG&E Temp. Gas Serv. Called PG&E JJOB ,�— FINALED S+ ;—S (Date) (Signaturef 7 v. f /sem X 14 9 COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING PLUMBING BUILDING (Cont'd) Setback JS -:�;— Firewall Soil Piping Forms Parapets 1st Floor "'p Main Bldg. Restroom Finish'---'---- 2nd Floor Footings fO - - Lj Windows -- Q - 25 3rd Floor Stemwal l Sidinq To out7�- Slab Roof Sheathing ,) Water Piping Piers Roofing Sewer - Garage dn. Vents Fixtures F o o t i n g s p A "' G Water Htr. StemwalI Prov. for physically Heaters Slab 5� Z ^ 7 handicapped Appliances Carport Conformance of ex. Gas Piping & Test - Footings structure Temp. Gas --�--� Slab Final - Z 8' ?J Sanitation Patio FIREPLACE Final Footings Footing drt t.- ELECTRICAL Masonry Walls < Throat Rough '"% Reinf. Steel Final Fixtures Bond Beam FIRE SPRINKLERS Motors vL. Framing - "7 Test Water Htr. } Stucco Final Subpanels ^��- %J Mesh MECHANICAL Grd. Fault Prot. ^' - 7 Scratch Heating - ^-7 Service Brown Cooling S� '" �- ^�.j Temp. Pole Finish Ducts a Underground Interior Lath Ventilation Permanent Door Closer Final cS g Final DATE REMARKS OR CORRECTIONS (� -- ! to - 7J �%'O U SCG P f �� l�G��°j �P�/�! ��"r W � rGCJ p"llv►ir . 0 COUNTY OF BUTTE — DEPAroITMENT OF PUBLICW R 575' 2 ._ 7 County Center Drive — Oroville, California 95965 Telephone: 534-4541 APPLICATION AND PERMIT authorize representatives o the County of Butte to enter upon the above-mentioned prope f inspection purposes. i�Ticvi'lJ Date / Signature of Permitee or Agent Receipt No-//�a (!R�s—o White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIREC OR OF PUBLIC WORKS By ' Date Building permit expires .Date ............�/ - /..?.(; BUILDING Owner SO. FT. OCC. BUILDING VALUATION �ry vG-92 Mai Iing Address Z ze� & &, C-9 49 ae6 /LLE Telephone No. 33 no Fireplace O, Q Q Contractor OW Al 4a Total Valuation Mailing Address Permit Fee Plan Checking Fee &/or Penalty Telephone Na. Permit Fee $ , 00 $ Building Address �-- PLUMBING No. .g.,[ FEE PERMIT FILING FEE Q Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 S'a Each gas water heater or vent 1.50 A. P. No 3 — �` Zoning & Planning Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 Fes W. F•reDept. Fire Zone Use Pen -nit Building sewer 5.00 EOA Parking Parcel Plans Declaration Parcel P 60' R/W Im r p ovements Lawn sprinkler system 2.00 Bldg. Plans Recd Parcel pproval Plans Approval Permit Fee $ S $ NEWSC ADDITION ❑ UTILITIES ❑ OTHER ❑ ELECTRICAL No.1 @ FEE PERMIT FILING FEE $3.00 00 Main service incl. 1 meter Additional meters, each 1.00 Sub-paGel (12 or less) (more n 12) �, S Single Family IN Duplex ❑ Mobil Home ❑ Others ❑ RaA41e, Cook -top or O 1.00 00 Water ter or Space Heater 1.00 20 10 i46 Light fixturesbal sw' fix ou s 36 MH&A, CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: `an or F. A. Fu n. Motor 41 1.001.0 © 0 Evap. cooler, gar p. or D 1.00 a Air�iO ditioner or heat pump / S Water pump Mobil Home Facilities 5.00 Temp. Power Pole 5.00 License No. Classification Misc. wiring I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑ I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. inI certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 3. dd Heating(� Cooling T— 00 Ventilation Hood / 2.00 - O �% Permit Fee $ 00 $ 13, oC I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby TOTAL PERMIT FEE $ 17 authorize representatives o the County of Butte to enter upon the above-mentioned prope f inspection purposes. i�Ticvi'lJ Date / Signature of Permitee or Agent Receipt No-//�a (!R�s—o White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIREC OR OF PUBLIC WORKS By ' Date Building permit expires .Date ............�/ - /..?.(; 24' i 24' 3 40' 6' HVAC ; 14' 11 IT, Sat Dish �(2) DC Disc. (2) Sunny Boy 2500 Inverter (1) AC Disc. Main service Fane) Si-�e flan Friedman, Robert & Cindy 1158- Mt, Ida, Rd, ❑roville, CA 95966-9408 (415) 845-8328 I 4,8 kW Roof mount, Grid -Interactive, Photovoltaic system (48). Astr.oPower 120 Watt panels, (2) SMA SWR25000 2.5 kW SunnyBoy Inverter n� k Issue z a � U U U O o6 J 1,0 +-1 ,D L M W 0)�LO00 z-�G"CU W d Q 00 75Uln Q�00 p {U Co o Ln 12 Ln S- 11- LL- —4 O .. A Sun Power Geothermal Energy 125 Larkspur St. Unit 117 San Rafael, CA 94901 4.15459-4201 CA Lie. #759086 Dmwbg Type. . Site Plan Friedman 4.8 kW UT Drawn By, Michael Clork (415) 4599--4201 Date- 20 JAN 03 S"ie' V = 10' Sheet. 1 of 4 4; N a am Vj a Q °d as a a a a 0 0 0 N N N -N, Q Q Q Q 0 w Q 0 � Q N Q 0 Q 3 NN N N N < a a a a a a a a ' U J 06 � +' �,D Z N p N Nz W In 00 1-5 ' -�-� -Q o � z Q 00 40/ ~� U ,n . 6' HVAC a a a a �UILDBi�G aERARi'ME W 0 o_�C�ol� T �LnLAPPROV'j) � J. No a a 0 a i • i P ; NN N N N . m 8 a a Q Q s Q i nd i ad 4 a c .Suri power 14' & Geothermal Energy i m 125 Larkspur St. Unit 117 O S, R_, ti 1 San Rafael, CA 94901 415-4594201 a a a a a CA Lic. tf759086 Sat. Dish Drawb,g Type, zz Roof Plan Job - 00000 x Friedman 4.8 kW UT Drawn By. (2) DC DISC. Michael Clark <415) 459-4 1 (2) Sunny Boy 2500 Inverter rpoof Ian (,) AC Disc. Date, 16 JAN 03 Scale, 3/16= 1' I Main Service Panel Shee4 2 of 4 T yp.acat -Sloped Roof -Mount .F- t u s l/ 15' R o -o f M b u n t 8• pr/ of!(e InS�� tea Washer 3ig._x q• /-Q_ TYpfc4l SOlar P \_ Beats T { a MP BOl t -S�l ct r PQ nPl x q. {�9s TYplo4l Rooftop Mounting Cross -Section 1une BPQm 4' maple Inter -Module clip Solar modute laminate �$lai^ +aelale -Ft^a-fte Extruded rail _ Channel nut Flash assembly ��Ftashing BU°id'E COUNTY BUILDING DEPARTME APPRUVEU Z o� Q £ o .0 J \ `D Li � O, 1� A Ln Z 75 G". 3 � -N O U �D Q ru U <0 Ln -Q� 4-> .X Q� Q-�°-> D�.P-.° 02°o( - ..n -ry .r_ n (24) Photovoltaic Modules (24) Photovoltaic Modules 4,8 W Photovottaic- System Cutler Hammer Non-Fusable Lockable : 3R 2 -pole 30AMP 600Vott DG261URB 1-#10 ground PV to Frame Bond— DC 1-#10 Ground bond 2-#10 RHW-2 Disc 2-#10 THHN 1-#10 ground PV to Frame Bond 1-#10 Ground bond— - - DC 2-#10 THHN 2-#10 RHW-2 Disc Array o- (48) AP -120 Watt 12 Volt DC each connected in series. AP 120-1 Voc 21.0 Volts AP 120-1 Vmp = 16.9 Volts Array Total Open Circuit Voltage -- 504. Volts Array Total Maximum Power Voltage . = 405,6 Volts Short Circuit Current = 7.7 AMPs Maxirlun Power Current = 7.10 AMPs Warning! Electrical Shock Hazard, Do Not Touch Terminals -on Both Line and Load Sides. May be Energized Meter PG&E Main House Grounding System Cutler Hammer Non-Fusable Lockable SMA SMA 3R 2 -pole 30AMP 600Vott SWR25000 SWR25000 DG261URB 2.5kW 2.5kW Sunny Boy Sunny Boy Inverter Inverter 240 VAC UL#E210376 UL#E210376 z I c _= o C) c # O 1 L . (U I o . 2 pole 50 AMP AC 2-#10 THHN AC I 4 Exterior Utility Breaker DISC 1-#10 Ground bond _j Cutler Hammer. Service Panel Non-Fusable Lockable 3R 2 -pole 60AMP 240Vott 8 V/ 8� 00 DG222URB BUILDING DEPT APPRn Z o � C5 00 o U �. a J L \ l �,D w >, -3 Z73IY�( (U Ou d000 I (__) 117 W L� =-00 0- 0) > ^ osQ001 0 i a/-oIfi� O` Q ED v Sun Power Geothermal Energy 125 Larkspur St. Unit 117 Sao Rafael, CA 94901 415-4594201 CA Lic. #759086 Drawing Type. Single Line Diagram Job, Friedman 4.8 UT Drawn Bye Michael Clark (415) 459-4201 M.L.. te. 20 Jan. 03 Scale - NTS of 4