Loading...
HomeMy WebLinkAbout079-370-045_ soft RESIDENTIAL 036-230-045 PERMIT#95-1105 MURRAY, Alva & Beatrice ! 525 Circle Dr., Oroville Add kitchen/SF JOB FINALED Signature } f J=OK , r. O = Not OK = Not Applicable MOBILE HOMES MISCELLANEOUS = Not Readyv Date MOBILE HOME UTILITIES (Plans) OK except #'s Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Sewer; Location -Test -Fall -C/O Concrete 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors 5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete Shthg.-Rfg.-Bracing 6. Gas; Location -Test -Wrap: ; /"L"ft. - ' 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures / /"Nat. or/ /" L"ft./ /"LPG 6. Carports; Windows -Doors 7. Well Clearance & Disconnect 7. Electric 8. Utility Clearance 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh ` 10. Roof; Shthg-Roofing Date _ Card B-1 Date Card B-1 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except.#'s 1. Zoning Requirements -Setbacks Easements -� .; , Date Card B-1 Date Card B-1 2. Footings; Size -Spacing -Marriage Line Date Card B-1 Date Card B-1 3. Gas; MH Test -Demand -Valve -Connector Date POOLS (Plans) OK except #'s 4. Electricity; MH Test -Crossovers -Breakers -Clearances 1. Setbacks -Easements '. 5. Drain; MH Test -Fall -Flex Connector 2. Soils; Compaction -Structure Stability 6. Water; MH Test -Regulator -Connector ' .+ 3. Pool Structure; Steel -Connections -Thickness 7. Water and Sewer Connected -C/O to Grade -HD Approval Dead Men -Lining - 8. Gas and Electricity Tagged 4. Elec.; Receptacles and Lighting, Distances-GFI 9. Exits; Insp.-Sketch 5. Elec.; Pool Lighting; 15 volts-GFI 10. Cert. of Occupancy 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Date Card B-1 Date Card B-1 - Boxes-Enclosures-Panelboards-Ins. to Main in Conduit Date Card B-1 Date Card B-1 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test • Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 } 2 t COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt ,Road; -Chico, CA - (916) 891-2751 7 County CenteeDflvB;t&oville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. Date CQ 2 Inspector- REV 10/92 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 89.1-2751 _ 7 County Center Drive, Oroville, CA - (916). 538-7541 ` 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE: MIA ki //O-�) OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. / I /�l Grim :���'C/�✓ �: �� X4%3 i Q v i Q do 1D DX /91/1 C GI � - Q— o6 4-C !J Date f IC7 Inspector REV 10/9 tix ;: r- M".Qi`�i,K*#t��'►'rrr'�'t+cJ•lr�i ri�c, ,ttiyfywrtric.rn�Yt'•t*�.+ ' COUNTY OF BUTTE - DEPARTMENT OF DEvMENTS SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 -TELEPHONE (916) 538-7541 / a. PERMITAPPLICATION DATA SHEET OWNER I ► k Lkr Proposed Building Use No. () Q(o Building Inspector QW Date At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED BY 1. All items have been submitted . ........................................ 2. Plot plans, 3/4 sets, signed by preparer of plans. ......................... . ' 3. Complete plans, 3/4 sets, signed by preparer of plans . ...................... ! 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............. 5. Hazardous Material Form. ............................................ su orcin ..........................:: �1 c Energy Design Compliance and supporting documentation . .................. ` Statement of Intent for Non -Heated and A/C Buildings . ................... . 8. Engineered truss details and layout in duplicate (required prior to plan check). ... . 9. Mobilehome data an anufactu er's i tallation instructions, 2 sets ............. O Fees of $ �. i o. ............. ................. Impact fees as shown on attached schedule.' 12. California Department of Forestry plan approva ees.7. 13. Flood elevation letter (100 year flood) by, alifor ' ngineer. . . 14. Sanitation and plot plan approval - Health Department . ............ 15. City of Chico plumbing permit . ........................................ . 16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: 18. Contact Land Development about (A) Improvements (B) Drainage ............. . . 19. Driveway permit (construction approval required prior to occupancy). .... Pre-Inspecti.on requ.� 20. Pre -inspection for required. . to Buad;ng 1pspector: (Date) 21. Contractor's license information. (No., Name Style, Classification). ..:............ 22. Certificate of Workmans Compensation Insurance . .......................... 23. Owner -Builder Verification (Given to owner Mail to owner _). .......... 4 24. Recorded copy of Agricultural Acknowledgement Statement .L` .................. 25. Letter of signature authorization . ........................................ 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. ..... 27. Letter of intent on building use . ........................................ . 28. Mobilehome utility clearance . .......................................... 29. Documentation of legal access . ..................... :.................. 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... 31. Existing violations/expired permits . ...................................... 32. Plan check list . ...................................................... 33. 34. Whou issue the permit, process as follows: Mail to owe . Mail to contractor. ✓ Telephone 5�4- f S�(p and hold for pickup at OyovL n office. Deliver with inspector. Other Parcel Creation ' Acreage Applicant Date Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept:,_Other Date By The following data must be submitted no t -rpit issuance: (Circle new item not checked above). 1. Index permit for above items No. - V 1A 2. Additional items required: LsE,s nl 1 CZ -10 qcql Contract r, i ner wrier, wli�s advised of above required data by phone _ mail Counter by _ Date 7 -ie, Contractor, designer( J^r `Z%Jlisl�9trof above required data by phone _ mail Counter by j&- Date `7• I -7-q Plans checked by GkG13ar/S Date ?~ Plans approved by GIBgo.-jS Date 7-11-q5 _3- Sets of plans on hold in File cabinet _C� AP folder Copy - Department of Public Works TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance USE Plot Phu Auac6ad Floor Plan Amcbed Seat to & - L�;&g / MQ9XAY6aS / mac ,e. 3 - -3o-C Owner Location AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well ClforQ/�r�r.D/�v r1! tWe-- r ONS ^ 6 • , K 1 ��h�Y Hold final for• Final cl ce O.K. for: ironmental Health 8/92 ist Date M, BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One Form Per Building) School District—Dm E I2Vt,q _— Building Department No A.P. Number--D�S: Jurisdiction: City (j County PropertyOwners UGL�-_� L'_ �(,c�i�' Property Location/Address Subdivison Lot No. Residential Development E-] `—r/� Sq. Footage_ No. of Living MHI Addition (Group R) Units Commercial/Industrial New Addition (Floor Plans reviewed by School District Personnel) District Identification No, _' chool District certifies that A-�� n n Al/.[� (Street Address) n (Ci Sq. Footage (Including Exterior Roofed Areas) ;z�/�.S Date (Applicant) (Phone Number) (Zip Code) has complied with the requirements of Resolution No. by by payment of $ representing b square feet. I AB 2926 $ PULL MITIGATION $ / C School Oistrict Representative Date Paid by Check # Remarks: SOU Bank Number Paid by Cash If, subsequent to the School District Representative signing this Butte County Schools.1mpact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitiqate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeformmkl (.11/94)dmm CDF FIRE SAFE REQUIREMENTS 036,-2.30-04S L)✓''a7 ,4 L 1 l -rice AP# PERMIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made a part of this permit. These requirements are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building Department for compliance. [k 1272.00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. Driveway Standards [ ] 1273.02 Surface. All driveway surfaces and structures (bridges, 1273.07 culverts and other app -,rte --sant structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds. 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius [ ] 1. No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional sur- face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. [ ] 2. The length of verti-_i:l curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. [ ] 1273.05 Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. [ ] 1273.05 Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. [ ] 1270.10 Width. All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance o feet along its entire length. vim Page 1 of : 2.-, ®U1��'� MjpAI SEN ' APPROVED F�c� coPy 03&-230-04S- dec.+P� AP # PERMIT # NAME [ ] 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. [ ] 1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall be within 50 feet of the building. 1273.11 Gates [ ] 1. Gate entrances shall be at least two feet wider than the roadway it serves. ] 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [ ] 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification 1276.01 Setback for Structure Defensible,Space. All parcels 1 acre- and larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from ul] property lines and/or the center of the road. [ ] 2. For parcels less than 1 acre, local jurisdiction shall provide for the same practical effect. See other Requirements below. 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping., burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shalom be completed prior to completion of. road construction :,r fi_ial inspection of a. building permit. 5 Page 2 of 3. 6 R - 23o-oY 9S-�io s AP # PERMIT # her Reauirements /yJvr,-a wa l3ca f7r/ c e - NAME [ ] If Buildina.Setback is -15 to 30 Feet: - Class A or B roof Enclosed eaves [ ] If Building Setback is Less Than 15 Feet Choose any 3 of .the following: Metal or no doors on side toward property line with insuffi- cient setback - Class A or B roof with enclosed eaves - Interior automatic sprinkler system per NFPA 13D - Glass area not to exceed i0t of wall area toward property line with insufficient setback - Siding from the following list: Stucco - 3 coat Hardi-Board or Plank Masonry Masonry veneer, Metal Other Butte County Fire Department approved materials Date Signature Page 3 of 3 X sas :C:Ol;lSTRUC`i''i0 'al C "� $ ZH:,,s L COMPLY 4`l '.. �a EDITION c;0F NEC, UNIG AP,4 D io This Set of picirrs ana specifications MUST bb kept on the jok -1t hl! times and it is unlawful to ar^< r:r alterations on tame without make any ch written permission from the Oenartment of PUW Works, County A7 L116 NOTE:—Ail Materials & Workmanship Shap DO " Accordance with Recognized Good Practices and of o quality prescribed for the Specified use in the Uniform Building, Plumbing & Mechanical Codes and she National Electrical Code. BUTTE pMNTY gVILM4 DEPARitJIENT APPROVED F<< -F- coloy n ' • r N c G G/ te d L �• 6 `^ rh II ii i `v �t2ovlDcuumil £ j 7��> V£R1F�cAr1o� cou��v QF Sur; E BUILDING DEPT J U L 0 3 1�1 APPROVED BUTTE COUNTY IMPACT FEES- . .B 1. Drainage 4/3/92 A. Thermalito Area (1) Residential - $425.00%living unit (2) Commerc.i.al - per schedule in Resolution 90-123 2. Recreation Districts A. Chico Area Recreation and Park (1) Residential - $1189.00/living unit`, (2) Commercial - None 3. School Districts A. All (1) Residential - per schedule of each district (2) Commercial - per schedule of each district 4. Sheriff A. Entire unincorporated area, (1.) Residential - $360.00/living unit; Multiple - $252.00/living unit (2) Commercial`.- $0.03/sq.ft. 5. Street Improvements P A. Chico Urban Area (1) Residential - $.1331.00/living unit; Multiple $804.00/living unit; Mobilehomes - $602.00/living unit �} (2) Retail - $1.75/sq.ft.; Office - $0.29/sq.ft.; Industrial - $0.10/sq.ft. (3) Other per schedule Exhibit A, Ord 2709 t B. Thermalito Urban Area (1) Residential - $507.00/living unit; Multiple - $304.00/living unit (2) Commercial - $20,280/acre developed; Office - $10, 140/acre (3) Industrial/Light - $5,070/acre; Heavy - $1,�014s/acre J *kS-�03% BUTTE COUNTY SUILOM DEPARTMENT COUNTY OF BUTTE APPROVED euILnwn n=PT J U L 0 3 1995 BUILDING DIVISION FAX COVER SHEET 3/21/95 TO: PG&E Service Planning Department PHONE: 894-4741 '+ FAX: 894-4737 } j FROM: Butte County Building Division'.' r PHONE: 538-7541 FAX: 538-2140 List of electric/gas clearances: :— ', j '• 1 OWNER ADDRESS DATE ELECTRIC GAS Kimball, Neal 4428 Olive Hwy, Oroville 3/21/95 X t CA tr y� ♦ - --{- , /1 l T IC V v r l r L W V%-� �� V Fil V �' klA! " 0] . Q �� 12 ll i�/ �/� 4 l / — 03.6 — o �0 ; h 1c ' l� �rn oss e�-� C,4 � od �e ,� es �-- The attached Fire Safe requirements must be compf . as specified and approved by C.D.F. . 4� C17 � T�'�,S „ �•�cn,� 3 �9 97 1 ND •. 3 � Location of sMICuMs & 9i.1 5 equipment shall be as -o�xiwn fs .�& dvkw bf all �. ,qq� = ��. ----- Oma" JD e. MPAF"EN' '�APPROVED CgRTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... --M nay gyp,-r'VVx_t Date........ 07/14/95 Project Address........ --------------------- Documentation Author... JIM PETERSON ; Building Permit # Company ................ Jim Peterson Telephone ................... (916) 343-7250 - ; Plan Check / Date Compliance Method'....... MICROPAS4 by Enercomp, Inc. ; Field Check/ Date Climate Zone........... 11--------------------- MICROPAS4 v4.01 File-MURRAY Wth-CTZ11S92 Program -FORM CF -1R User#-MP0400 User -Jim Peterson Run -HOUSE ------------------------------------------ GENERAL INFORMATION Conditioned Floor Area..... 1140 sf Building Type .............. Single Family Detached Construction Type ......... New Building -Front Orientation. Front Facing 270 deg (W) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade (Package D) BUILDING SHELL INSULATION Component Insulation Assembly Type R -value U -Value Location/Comments ------------- Wall ---------- R-13 -------- ---------------------------------------- 0.082 Roof R-38 0.029 S1abEdge R-0 0.900 S1abEdge R-0 0.720 FENESTRATION Over - Area U- # of Interior Exterior hang/ Framing Orientation ------------------- (sf) ----- Value Panes Shading Shading Fins Type Window Front (W) 22.0 ----- 0.650 ----- 2 ---------- Roller.Lt -------------- None ------ -------- Yes Metal Window Left (N) 20.0 0.650 2 Roller.Lt None Yes Metal Window Back (E) 8.0 0.650 2 Roller.Lt None Yes Metal Door Back (E) 40.0 0.750 2 Roller.Lt None Yes Metal Window Right (S) 16.0 0.650 2 Roller.Lt None Yes Metal THERMAL MASS ------------ Area Thickness Type Exposed (sf) (in) Location/Comm o"TY ------------ -------------- S1abOnGrade No ------ 764 --------- 3. 5 - - - - - - - - Covered - - - - - ----------- Bljrit' 1t� DEPAr►TtAIEN S1abOnGrade Yes 376 3.5 Covered" ���`S� AP v D CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R --------------------- ----------------------------- roject Title. ----------------------- Date....... . 07/14/95 ----------------------------------------------------------------- ------------------- ------------- ----------------------- MICROPAS4 v4.01 File-MURRAY Wth-CTZ11S92 Program -FORM CF-1R -----------------User#_MP0400--User_Jim Peterson Run -HOUSE i ----------------------------------- HVAC SYSTEMS ... ..... _-. -------- Minimum Duct Duct Thermostat Equipment -Type- - - - Efficiency R_value -- Type ---------- Furnace 0.780 AFUE Attic R-5.6 Setback ACSplit 10.80 SEER Attic R-5.6 Setback WATER HEATING SYSTEMS --------------------- Number Tank in Energy Size Tank Type Heater Type Distribution Type System Factor (gal) -- ---- ---- ______ ___ ------------------- __ Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS ------------------------ 41 External Insulation R -value CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R ----------------------------------- Project Title.......... Date .. 07/14/95 ' MICROPAS4 v4...01..File-MURRAY Wth-CTZ11S92 Program -FORM CF -1R User#-MP0400 User -Jim Peterson Run --HOUSE i ----------------------------------------------------------------------------- COMPL IANr_.F STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative- regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this.certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... JIM PETERSON Company. - - Address. 341 BROADWAY #207 CHICO.CA. 95928 Phone... (916) 343-7250 License. Signed.. -.� --3 - �4 (date) ENFORCEMENT AGENCY Name .... Title... Agency. - — - ------ - - Signed.. _� ------ --- - (date) a DOCUMENTATION AUTHOR Name.... JIM PETERSON Company. Jim Peterson Address. 341 Broadway #207 Chico,, California 95928 Phone... (916) 343-7250 Signed. ( date') MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- Project Title.......... _ _ Date........ 07/14/95 Project Address........ --------------------- Documentation Author... Company ................ Telephone .............. JIM PETERSON Jim Peterson (916) 343-7250 Building Permit # Plan Check / Date ; i Compliance Method...... MICROPAS4 by Enercomp, Inc. ; Field Check/ Date Climate Zone........... 11 --------------------- MICROPAS4 v4.b1 File-MURRAY Wth-CTZ11S92 Program -FORM MF -1R , User#-MP0400 User -Jim Peterson Run -HOUSE ' ------------------------------------------------------------------------------- Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturers labeled R -Value. _ *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior imass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 1 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal -.or glass door b. Outside air intake with damper and control c. Flue -damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL _ ---''Page 2- Project Title...... -- 07/14/95 -------------------------------------------------- --- Date..... MICROPAS4 v4.01 File-MURRAY Wth-CTZ11S92 Program -FORM MF -1R User#-MP0400 User -Jim Peterson Run -HOUSE i ---------------------------------- SPACE,.CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design - 110 -13: HVAC equipment, water heaters, showerheads and faucets er certified by the CEC. 150(1): Setback thermostat on all applicable heating systems. / 150(j): Pipe and Tank insulation —�- 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation PUMP time switch. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning Pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.). LIGHTING MEASURES ----------------- 150(k): 40 lumens/watt or greater for general lightinin kitchens and rooms with water closets; and recess fixtures IC (insulation cover) approved. edceiling l M Enforce- ment Design- Enforce- er ment COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... ---- —�-- _ _ Date........ 07/14/95 Project Address..... _____________________ Documentation Author... JI'M PETERSON ; Building Permit -# Company.................. Jim Peterson Telephone .............. (916) 343-7250 ; Plan Check / Date Compliance -Method...... MICROPAS4 by Enercomp, Inc. ; Field Check/ Date Climate Zone...... 11 MICROPAS4 v4.01 File-MURRAY Wth-CTZ11S92 Program -FORM C -2R User#-MP0400 User -Jim Peterson Run-HOUSE ------------------------------------------ ------------------------ MICROPAS4 ENERGY USE SUMMARY = _----------------------- = Energy Use Standard Proposed Compliance = _ (kBtu/sf-"yr) ---------------------------------- Design Design Margin = = Space Heating.......... 16.35 ---------- 13.08 ----------- - 3.27 = = Space Cooling.......... 1i.69 14.64 -2.95 = = Water Heating.......... 17.13 17.13 0.00 = = Total 45.17 44.85 0.32 = _ *** Building complies with Computer Performance GENERAL INFORMATION ------------------- Conditioned Floor Area..... Building Type.............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor ---Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... a 1140 sf - Single Family Detached New Front Facing 270 deg (W) 1 1 FullYear Slab On Grade 1 7200 cf 1140 sf 1140 sf 1140 sf 9.3 % of FA 6.3 ft (Package D) COMPOTER METHOD SUMMARY Page 2 C -2R Project Title.......... Date .. 07/14/95 ----------------------------------- MICROPAS4'v4.'01 File-MURRAY Wth-CTZ11S92 Program- -FORM C -2R User.#-MP0400 User -Jim Peterson Run -.HOUSE ' ------------------------------------------------------------------------------- BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) ----------------------- (cf) Units itioned Type --------- ----- (ft) (sf) HOUSE ------------------- ------ --------- Residence 1140 7200 1.00 Yes Setback 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface -(sf) value R-val Azm Tilt Gains Reference Comments -------------- ------ ----- ----- --- ---- ----------------- ---------------- HOUSE 1 Wall 218 0.082 R-13 270 90 Yes W.13.2X4 2 Wall 220 0.082 R-13 0 90 Yes W.13.2X4 3 Wall 192 0.082 R-13 90 90 Yes W.13.2X4 4 Wall 224 0.082 R-13 180 90 Yes W.13.2X4 5 Roof 1140 0.029 R-38 0 0 Yes R.38.2X12.16 PERIMETER LOSSES ---------------- Length F2 Insul Surface (ft) Factor R-val Location/Comments ------------ --------------------- ---------------------- HOUSE 6 S1abEdge 45 0.900 R-0 7 SlabEdge 94 0.720 R-0 FENESTRATION SURFACES --------------------- SC SC Interior Area # of Frame Open U- Act Glass Int Shade Surface ---------.-- (sf) ----- Panes Type Type value Azm Tilt Only Shade'Description HOUSE ----- -------- ------ ----- --- ---- ----- ----- ------------ 1 Window 18.0 2 Metal Slider 0.65 270 90 0.88 0.37 Roller.Lt 2 Window 4.0 2 Metal Slider 0.65 270 90 0.88 0.37 Roller.Lt 3 Window 8.0 2 Metal Slider 0.65 0 90 0.88 0.37 Roller.Lt 4 Window .12_.0 2 Metal Slider 0.65 0 90 0.88 0.37 Roller.Lt 5 Window 4.0 2 Metal Slider 0.65 90 90 0.88 0.37 Roller.Lt 6 Door 40.0 2 Metal Slider 0.75 90 90 0.88 0.37 Roller.Lt 7 Window 4.0 2 Metal Slider 0.65 90 90 0.88 0.37 Roller.Lt 8 Window 8.0 2 Metal Slider 0.65 180 _90- 0.88 0.37 Roller.Lt 9 Window '8.0 2 Metal Slider 0.65 180 90. 0.88 0.37 Roller.Lt COMPUTER METHOD SUMMARY -- Page 3-- C -2R Project Title.......... Date.. ------------------------------------------ MICROPAS4 v4.01 File-MURRAY Wth-CTZ11S92 Program -FORM C -2R User#-MP0400 User -Jim Peterson Run-HOUSE ------------------------------------------------------------ OVERHANGS AND SIDE FINS THERMAL MASS Area Thick ---Window-- ------Overhang----- Surface Mass Type -----------.---- ---Left Fin--- ---Right Fin -- ivity R -value Location/Comments Area ------- ---------- ----- -------- Left Rght 764 3.5 28.0 0.98 R-2.0 Covered 2 SlabOnGrade Surface - (sf) ----- Hght ----- Wdth ----- Dpth ---- Hght ---- Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE ---- ---- ---- ---- ---- ---- ---- ---- 1 Window 18.0 6.0 3.0 2.0 1.5 n/a n/a n/a- n/a n/a n/a n/a n/a 2 Window 4.0 2.0 2.0 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 8.0 4.0 4.0 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 12.0 2.0 6.0 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 4.0 2.0 2.0 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 6 Door 40.0 6.8 6.0 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 4.0 2.0 2.0 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 8.0 4.0 2.0 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 8.0 4.0 2.0 2.0 1.5 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS HVAC SYSTEMS Area Thick Heat Conduct- Surface Mass Type -----------.---- (sf) ------ (in) ----- Cap ivity R -value Location/Comments HOUSE ------- ---------- ----- -------- -------- -------------------------- 1 SlabOnGrade 764 3.5 28.0 0.98 R-2.0 Covered 2 SlabOnGrade 376 3.5 28.0 0.98 R-0.0 Covered HVAC SYSTEMS WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System --Factor (gal) R -value ------------ ----------- ------------------- -------------- ------ --------- Water Heater to..meet minimum CEC Standards - SPECIAL FEATURES/REMARKS ------------------------ Minimum Duct Duct Duct . System Type ---------------- Efficiency ------------ Location R -value Efficiency HOUSE ------------- ------- ---------- Furnace 0.780 AFUE Attic R-5.6 0.837 ACSplit 10.80 SEER Attic R-5.6 0.823 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System --Factor (gal) R -value ------------ ----------- ------------------- -------------- ------ --------- Water Heater to..meet minimum CEC Standards - SPECIAL FEATURES/REMARKS ------------------------ 11 oj ALL STRUCTURES AND EQUIPMENT INCLUDING OVERHANGS SHALL BE CLEAR OF ALL EASEMEN'r& A SET BACK OF _._1.3-D FT. FROI-0 -nif--: SIDE AND 3 0 FT. FROM THE —REAR PROPERTY LiPE;SAND ro- Fr. " I " *'-* F:: 0 0 1 J' CE,". T E R L. I Ni E 6� A B E CLETR rX-7 s'j*p'Jlfl'T!jri.r--"-, AND FOR A 2 IzT. EA` EOVIivto%jvO. amwUNTY REVIEWED BY 9LM.Wo DEpA"EN*l BUTTE CO. FIRE DEPT. UALir. DEP;. of FC-'i:WRY approve."J'a's -h at t .5 APPROVED