Loading...
HomeMy WebLinkAbout001-061-034OEMOWmEHf SERVICES BUTTE COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES 1 INSPECTION CARL) MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) :530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530 Permit No: B17-2986 Issued: 12/19/2017 APN: 001-061-034 Address: 3017 6TH ST, BIGGS Owner: JIMINEZ ARTURO & ROSA M Permit Type: SOLAR ROOF -RES Description: Installation of 5.01 kw PV solar energy system :)szs. i izs:) www.tsutteuounty.nettaas Flood Zone: X (Shade SRA Area: LRA Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Tyne 1VR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footin2 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Sign d Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nder inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed ShearwallB.W.P.-Interior 134 ShearwallB.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 Manometer Test 605 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 , Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final • 8.13 Fire Sprinkler Test or Final 702 1 _+ - I Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimmin2 Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nder inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Under round Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Ski rtin Ste s/Landin s 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Finals .. Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT L -rrolect Anal Is a l.'erthLcate of occupancy for -(Residential unly) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION DATE: Arturo Jimenez O 1/4/2018- � I L UM S O L a r - 3017 SIXTH ST ROBERT DEAN ILUM SOLAR INC BIGGS CA 95917 82026TH ST APT #5 f • , SACRAMENTO. CA 95815 ' , t • _ - LICENSED ELECTRICAL CONTRACTOR t _ .COMPANY: ti•' • - ` _ ' _ • • ILUM SOLAR INC LICENSE NUMBER: . 4 • !.. t _ .. _ 1009260 - SCOPE 'OF WORK: THE SYSTEM CONSISTS OF A 5.02, KW DC (3.80 KW AC) -ROOF-MOUNTED PHOTOVOLTAIC POWER SYSTEM OPERATING IN PARALLEL WITH THE UTILITY. GRID. THERE ARE (17) JKM295M-60 MODULES AND (1) SOLAR EDGE SE3 80OH-US STRING INVERTER.' . '.CONNECTING TO THE UTILITY GRID THROUGH THE EXISTING MAIN LOAD CENTER. ELECTRICAL MODIFICATIONS` }WILL BE MADE TO THE MAIN LOAD CENTER: +_ 3 av i INTERCONNECTION METHOD: LOAD -SIDE BREAKERti ROOF -MATERIAL: Composite Shingled •- OW f PROTECT WILL COMPLY- WITH THE 2016„CRC; 2016, CEC; ,2016 GBC;. AND X2016 CFC;,,2015 IRC, 2014 NEC; ,2015 .IBC, .2015= IFC. TABLE OF CONTENTS PV 1.0 COVER PV 2.0 SITE PLAN PV 3.0 ' ROOF PLAN PV 4.0 LOCATION NOTES PV+5.0 MOUNTING DETAILS PV 6.0 SYSTEM MARKINGS PV 7.0 LABELING EL 1.0 ONE -LINE DIAGRAM EL 2.0 ELECTRICAL NOTES SHEET: - � �. - . � + .• .. � ..:..• �. � • .= •, . � : . � ��� ` . • _ � + _ . • : - . r : � �� - - • , � �,� . � - .. - -COVER • t ` y ' r � ~•? • t r. +�ry �r ,t` � .. '+� yF '' lj .+' "o , =PV 1.0 ' .1 `. /'Jlicc.... r 1..� . .,..,A. • • `fin'.” • S A _ ♦ i •/ �n. • .•r . • • �r . J � r ., . LS a i . • _ ? . 1, - t r - 4 ^ � � r '• r , i.. . � SHEET: - � �. - . � + .• .. � ..:..• �. � • .= •, . � : . � ��� ` . • _ � + _ . • : - . r : � �� - - • , � �,� . � - .. - -COVER • t ` y ' r � ~•? • t r. +�ry �r ,t` � .. '+� yF '' lj .+' "o , =PV 1.0 ' .1 `. /'Jlicc.... r 1..� . .,..,A. • • `fin'.” • S A _ ♦ i •/ SCALE: 5 (ll) lew n(' )A1 17 0Tv'Tu 0 I SCALE: /:`� � PV 3.0 FROM 2009 ASHRAE HANDBOOK - FUNDAMENTALS WEATHER DATA HIGH TEMP, 2% AVG. 38 °C MIN DESIGN TEMP -3 °C GROUND SNOW LOAD. 0 psf WIND SPEED 110 mph: :. MONTH 2% DRY BULB' TEMPERATURE FOR ASHRAE LOCATION FROM 2009 ASHRAE HANDBOOK - FUNDAMENTALS 1. HIGH TEMPERATURE 2% AVERAGE BASED ON ASHRAE HIGHEST 8. PV INSTALLATION SHALL NOT OBSTRUCT ANY MONTH 2% DRY BULB' TEMPERATURE FOR ASHRAE LOCATION PLUMBING VENTS; MECHANICAL EQUIPMENT, MOST SIMILAR TO INSTALLATION LOCATION MECHANICAL VENTS; OR BUILDING ROOF 2. MINIMUM DESIGN TEMPERATURE BASED ON ASHRAE MINIMUM VENTS IN ACCORDANCE WITH CPC 901.1, CPC MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION : 906, AND CMC 304. MOST SIMILAR TO INSTALLATION LOCATION 9. CONNECTORS THAT ARE NOT READILY _ 1 ALTERNATE POWER SOURCE PLACARD SHALL BE PERMANENTLY ACCESSIBLE AND THAT ARE USED IN THE , ATTACHED TO A/C DISCONNECT. CIRCUITS OPERATING AT OR OVER 30V AC OR' ; 4. 'ELECTRICAL INSTALL SHALL COMPLY WITH 2016 CALIFORNIA DC SHALL REQUIRE A TOOL FOR OPERATING - ELECTRICAL CODE (INCLUDING AN "ALTERNATE POWER SOURCE AND ARE REQUIRED TO BE MARKED "DO NOT PLACARD") , DISCONNECT UNDER LOAD" OR "NOT FOR 5. ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS CURRENT INTERRUPTING" w SHALL BE BONDED 10. THIS SYSTEM IS IN FULL COMPLIANCE WITH 6. IF THE EXISTING MAIN SERVICE DOES NOT HAVE VERIFIABLE THE CALIFORNIA FIRE CODE FOR GROUNDING ELECTRODE, IT IS THE PV CONTRACTOR'S PHOTOVOLTAIC INSTALLATION.AND ARTICLE. :. RESPONSIBILITY TO INSTALL A SUPPLEMENTAL. GROUNDING 690 OF THE NATIONAL ELECTRIC CODE (NEC ELECTRODE .: NFPA 70) 7. EACH MODULE -SHALL BE GROUNDED PER MANUFACTURER 11. BUILDING CONSTRUCTION. TYPE: TYPE V' INSTRUCTIONS AND APPROVED METHODS,12 . • BUILDING OCCUPANCY TYPE: R3 - - o LUMSOLar .. : ' ... SHEET: . :. LOCATION NOTES P'V'4.0 PHOTOVOLTAIC :MSI ALPHA+ RAIL : � :. •. . � • - MODULE ... � L=FOOT � • G ECOFASTEN COMP _ SHINGLE MOUNT FLASHING- LASHING Ito 18-8 SS LAG SCREW. 21/2 IN. EMBEDMENT PLYWOOD • ;., COMP SHINGLE ROOF RAFTER, TILT. S OR TRUSS: - • - -• - • ..190 _. SHEET: _ 'MOUNTING DETAILS - PHOTOVOLTAIC DC DISCONNECT. CEC 690.14 (C)(2) LOCATED ON THE DC DISCONNECT PORTION OF THE INVERTER (FOR STRING INVERTERS, NOT APPLICABLE TO MICRO -INVERTERS) CEC-690.14(C)(2) LOCATED ON THE AC DISCONNECT. - I CEC 690.17 & CEC690.54 LOCATED.ON-MAIN SERVICE PANEL WARNING: DUAL POWER SOURCES THIS EQUIPMENT FED BY MULTIPLE SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT AMPS AC NORMAL OPERATING VOLTAGE. VOLTS CEC 690.54 &'CEC 705.12.(D)(7) PLACE ON MAIN SERVICE PANEL AND ON SOLAR PV WARNING: ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BB ENERGIZED IN THE OPEN POSITION CEC 690.17 & CEC 690.54 PLACED ON OR ADJACENT TO THE AC DISCONNECT AND DISCONNECTING MEANS (SOLAR PV BREAKER) WARNING: ELECTRIC SHOCK HAZARD GROUNDED. CONDUCTORS MAY BECOME UNGROUNDED AND ENERGIZED IF A GROUND FAULT IS INDICATED COMBINER PANELBOARD _ CEC 690.5 (C) PLACED ON ALL INVERTERS AND JUNCTION BOXES, • . OR PLACED NEAR THE.GROUND-FAULT INDICATOR AT A VISIBLE LOCATION PV RVRTRM AC. I)TCC ANNRCT - PLACED NEXT TO THE SOLAR PV BREAKER AND ON AC . SYSTEM ARE UNGROUNDED AND MAY BE CEC 690.56 (B) &.(C) DISCONNECT:. ENERGIZED LOCATED ON THE AC DISCONNECT AND ALL JUNCTION BOXES AT ARRAY LEVEL ' PLACED ON ALL INVERTERS, JUNCTION BOXES AND SOLAR PV COMBINER'- WARNING: OMBINER WARNING: PHOTOVOLTAIC POWER .SOURCE _ '. PANELBOARD. -. CRC R331.2 :. PLACED ALONG'DIRECT.CURRENT CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES WARNING' INVERTER OUTPUT CONNECTION. PV MODULE SPECIFICATIONS STRING -INVERTER SPECIFICATIONS r *ALL CONDUIT WILL BE PAINTED TO MATCH MODULE MAKE AND MODEL JKM295M-60 INVERTER MAKE AND MODEL SOLAR EDGE SE380OH-US THE EXISTING MAXIMUM POWER (DC) 295 WATTS RATED OUTPUT POWER (AC) 3800 WATTS STRUCTURE. MAX POWER -POINT VOLTAGE (VMPP) 32.4 VOLTS NOMINAL OUTPUT VOLTAGE (AC) 240 VOLTS AC DISCONNECT - MAX POWER -POINT CURRENT (IMPP) 9.10 AMPS MAX OUTPUT CURRENT (AC) 16 AMPS LOCATED NEXT TO OR WITHIN 10 FEET OF OPEN CIRCUIT VOLTAGE (VOC) 39.7 VOLTS" MAX INPUT VOLTAGE (DC) 480 VOLTS MAIN SERVICE SHORT CIRCUIT CURRENT"(ISC) 9.61 AMPS MAX INPUT CURRENT (DC) 10.5 AMPS PANEL (LINE OF SIGHT. - MAINTAINED). TEMPERATURE COEFFICIENT VOC -0.39 %/°C MAX OCPD RATING (AC) 20 AMPS MAXIMUM SYSTEM VOLTAGE 1500V DC (UL) MAX NUMBER OF PANELS PER STRING 20 PV CIRCUIT 1: 17 MODULES/SERIES , • • . VISIBLE LOCKABLE "KNIFE" A/C 1�/1 DISCONNECT 30A/240V ' SOLAREDGE POWER OPTIMIZER P320 SOLAREDGE INVERTER 10JA BIGGS PRODUCTION METER If Hill + + M 20 JUNCTION BOX LOCATED ON ROOF PV MODULE .. A B C C C EXISTING 240V/100A BUSBAR RATED . LOAD -CENTER (NON -CENTER FED) PANEL. BREAKER WILL BE FURTHEST POSITION AWAY FROM DISCONNECT. 5.02 kW DC 3017 SIXTH ST 3.80 kW AC BIGGS; CA 95917 17 MODULES RACEWAY AND CONDUCTOR SCHEDULE AC PHOTOVOLTAIC SYSTEM RATINGS MAX AC OPERATING CURRENT 16 AMPS MAX AC OPERATING VOLTAGE 240 VOLTS TAG CONDUCTOR TYPE MINIMUM WIRE SIZE # OF CONDUCTORS RACEWAY / CABLE_TYPE MINIMUM CONDUIT SIZE .' PV CABLE 10 . 2 USE -2 / FREE AIR A N/A BARE COPPER (EGC) 6 1 BARE / FREE AIR THWN-2 OR MC CABLE : 10 . Z B EMT / MC 3/4" THWN-2 OR MC CABLE (EGC) 8 1 •ROMEX WILL BE RAN THROUGH THE ATTIC WHERE" POSSIBLE C THWN-2 8 3 EMT 3/4^ I L U m S o L a r •• IF MORE THAN 12 CONDUCTORS, TWO SEPARATE THWN-2 (EGC) S 1 : SHEET: RACEWAYS MAY BE INSTALLED WITH NO MORE THAN 12 LINE DIAGRAM CONDUCTORS IN EACH RACEWAY OTHERWISE, #8 WIRE - AND 3/4" CONDUIT MUST BE USED WHERE APPLICABLE EL ".• -1.0 GROUNDING CONDUCTOR ALLOWS FOR 1. SOLAREDGE STRING INVERTERS (SE3000H-US, SE3800H-US, SE5000H-US, EQUIPMENT TO BE USED AS THE SE6000H-US, SE7600H-US, SE 10000A -US, AND EQUIPMENT GROUNDING CONDUCTOR IN SE 11400A -US) MEET THE SYSTEM A PHOTOVOLTAIC SYSTEM. SPECIFICALLY, . GROUNDING REQUIREMENTS OF THE "DEVICES LISTED AND IDENTIFIED FOR NATIONAL ELECTRICAL CODE ARTICLE GROUNDING THE METALLIC FRAMES OF 690.41, TITLED "SYSTEM GROUNDING": PV MODULES OR OTHER EQUIPMENT 2. NEC ARTICLE 690.43 EQUIPMENT SHALL BE PERMITTED TO BOND THE GROUNDING SPECIFIES THAT ALL EXPOSED METAL SURFACES, OR OTHER EXPOSED NON -CURRENT -CARRYING EQUIPMENT TO MOUNTING METAL PARTS- OF PV MODULE FRAMES, SURFACES." THE DEVICES LISTED AND ELECTRICAL EQUIPMENT, AND IDENTIFIED FOR GROUNDING THE CONDUCTOR ENCLOSURES SHALL BE EQUIPMENT MAY BE STAND-ALONE PROVIDED. WITH EQUIPMENT GROUNDING. GROUNDING COMPONENTS OR UL -2703 690.43(C) STRUCTURE AS EQUIPMENT LISTED MOUNTING HARDWARE." ILUMSOLar SHEET: - Qi�umso�ar 4 2 3 4 5 A B C p E t F www.jinkosolar.com An= _ Engineering Drawings: ,•.. Building Your boat In Solar .' - - �,] . (•-"� x' ]' Cur]om•VdtagoB Powarvvoltnga TompaaW,o Dopenoonco Curvos (210M - _ of tsc voo,Pmax PERC • - - . 1 { - 280-300Watt-xx W MONO • • • . - °- V ° m W f W mex Positive powci folcroncla of • °° ` I ` F_ S:Ce link certified factory.y - - - vol"e(v) em Tent/- ­"ea - IEC61215. IEC61730 certified products. a Mechanical Characteristics .• 4� - r.r`t • ,J�i Cell Type Mono -crystalline PERC 1S6.156mm (6 inch) • -• J IIL•.JII No.ofcells 60(6x10) • ! Dimensions 1650x992x4Omm-(65.00x39.050.57 inch) • "' weight • 19.0 kg (41.91bs) _ Front Glass 3.2mm, Anti -Reflection Coating, KEY FEATURES High Transfission, LowIIron, Tempered Glass ' Packaging Configuration - Frame__ __ Anodized Aluminium _Alloy • ( Two boxes=One pallet) 'Junction Box IP67 Rated 4 BUSbor Solar Cell: 26pcs/box, 52pcs/pallet 728 pcs/40'HQ Container .Output -Cbl,, TGV 1 x4.Omm: Length: 900mm or Customized Length ' 4 busbar solar cell adopts new technology to Improve the efficiency of •' - - modules , offers a better aesthetic appearance, making it perfect for rooftop Installation. -High Efficiency: Efficiency: iHigher module conversion efficiency(up to 18.33%) benefit from Possivated Emmiter Rear Contact (PERC) technology. Module Type JKM28OW60 JKM28SM-60 ' JKM29OM-60 " JKM295M-60 JKM30OM-60 , PID RESISTANT: I m • Limited power degradation of Eagle module caused by PID effect is SfC NOCT,�_STC_NOCT��S OCT�.STC•�NOCT STC OCT guaranteed under strict testing condition (85 C/85%RH.96hours) for mass Maximum Power (Pmax) 28OWp 209Wp 285Wp 212Wp 290Wp 216wp 295Wp 220Wp, 300Wp, 224Wp • _ production. - - "'. Maximum Power Voltage (Vmp) 31.84 29.74 32.0V 29.94 32.24 30.24 32.dV 30.4V 32.6V 30.6V x ` -' LOW -light Performance: ` Maximum Power Current (Imp) B.61A 7.011A _ 8.90A . 7.12A 9.02A 7.15A --9JOA 7.24A 9.21A 7.32A . Advanced glass and solar cell surface texturing allow for excellent - Open -circuit Voltage (Vo 038.64' 36.2V 38.7V 36AV 39.SV 36.6V 39.7V 38.84 40.14 37.04 performance in low -light environments. _ r' ' Short-circuit Current (Isc) 9.49A 7.62A 9.51A 7.72A 9.55A 7.81A 9.61A 7.89A 9.72A 8.01A 1111 Severe Weather Resilience: Module Efficiency STC (%) 17.11% 17.41% 17.72% 18.02% 18.33% ILUMsOWr ° ROBERT DEAN, ILUM SOLAR INC. 820 26TH ST. APT #6. ' SACRAMENTO, CA 95816 PHONE: (9i 6) 905-0941 LIC. No.: 109260 G H :Operating Temperature(Y) www.jinkosolar.com An= _ Engineering Drawings: ,•.. Building Your boat In Solar .' - - �,] . (•-"� x' ]' Cur]om•VdtagoB Powarvvoltnga TompaaW,o Dopenoonco Curvos (210M - _ of tsc voo,Pmax PERC • - - . 1 { - 280-300Watt-xx W MONO • • • . - °- V ° m W f W mex Positive powci folcroncla of • °° ` I ` F_ S:Ce link certified factory.y - - - vol"e(v) em Tent/- ­"ea - IEC61215. IEC61730 certified products. a Mechanical Characteristics .• 4� - r.r`t • ,J�i Cell Type Mono -crystalline PERC 1S6.156mm (6 inch) • -• J IIL•.JII No.ofcells 60(6x10) • ! Dimensions 1650x992x4Omm-(65.00x39.050.57 inch) • "' weight • 19.0 kg (41.91bs) _ Front Glass 3.2mm, Anti -Reflection Coating, KEY FEATURES High Transfission, LowIIron, Tempered Glass ' Packaging Configuration - Frame__ __ Anodized Aluminium _Alloy • ( Two boxes=One pallet) 'Junction Box IP67 Rated 4 BUSbor Solar Cell: 26pcs/box, 52pcs/pallet 728 pcs/40'HQ Container .Output -Cbl,, TGV 1 x4.Omm: Length: 900mm or Customized Length ' 4 busbar solar cell adopts new technology to Improve the efficiency of •' - - modules , offers a better aesthetic appearance, making it perfect for rooftop Installation. -High Efficiency: Efficiency: iHigher module conversion efficiency(up to 18.33%) benefit from Possivated Emmiter Rear Contact (PERC) technology. Module Type JKM28OW60 JKM28SM-60 ' JKM29OM-60 " JKM295M-60 JKM30OM-60 , PID RESISTANT: I m • Limited power degradation of Eagle module caused by PID effect is SfC NOCT,�_STC_NOCT��S OCT�.STC•�NOCT STC OCT guaranteed under strict testing condition (85 C/85%RH.96hours) for mass Maximum Power (Pmax) 28OWp 209Wp 285Wp 212Wp 290Wp 216wp 295Wp 220Wp, 300Wp, 224Wp • _ production. - - "'. Maximum Power Voltage (Vmp) 31.84 29.74 32.0V 29.94 32.24 30.24 32.dV 30.4V 32.6V 30.6V x ` -' LOW -light Performance: ` Maximum Power Current (Imp) B.61A 7.011A _ 8.90A . 7.12A 9.02A 7.15A --9JOA 7.24A 9.21A 7.32A . Advanced glass and solar cell surface texturing allow for excellent - Open -circuit Voltage (Vo 038.64' 36.2V 38.7V 36AV 39.SV 36.6V 39.7V 38.84 40.14 37.04 performance in low -light environments. _ r' ' Short-circuit Current (Isc) 9.49A 7.62A 9.51A 7.72A 9.55A 7.81A 9.61A 7.89A 9.72A 8.01A 1111 Severe Weather Resilience: Module Efficiency STC (%) 17.11% 17.41% 17.72% 18.02% 18.33% ILUMsOWr ° ROBERT DEAN, ILUM SOLAR INC. 820 26TH ST. APT #6. ' SACRAMENTO, CA 95816 PHONE: (9i 6) 905-0941 LIC. No.: 109260 5 , 25 Years DATE: 01.04.2017 The company reserves the final night for explanation on any of the information presented hereby. EN.JKM--r300M-60-PERC_1.0_rev2017 DESIGN BY: R.D. ] s. CHECKED BY: R.D. REVISIONS : A' B 43 , C l D E. 4. F D_1. Certified to withstand: wind load (2400 Pascal) and snow load (5400 Pascal). :Operating Temperature(Y) .40°C-+8SY " • - ' - Durability against extreme environmental conditions:.. - - Maximum rystem voltage _ _ _ _ Maximum series fuse rating _ _ i000VDC (IEC) _ ISA . High salt mut and ammonia resistance certified by TU V NORD. Power tolerance - _ 0-+3% - --� _ « • , ,. • .. - Temperature coefficients of Pmax - . -0.39%PC «' " 1' LINEAR PERFORMANCE WARRANTY Temperature coefficients of Voc_ of _ _ _ -0.29%YC Temperature coefficients Isc- 0.o5%rC + 10 Year Product Warranty 25 Year Unear Power Warranty Nominal operating cell temperature (NOCT) _ _45=2'C _ _ '• - • ' . �` CC PV CYCLE ENERGY CE (0 LEAN „�,,,,,.,, cal1NCIL • `r ! " PaMITIVE 0!y TY' - MF?taER . - - F . - - s . • - t •• •• .,•• • inear performance warranty•c' • ' .. , f _ , •. O 97%95A '4dailiorbwaaeJr d StdndardperfonnancewananN *.STC: clrradiance.1000W/mz Cell. Temperature 25°C AM 1'S • .. Nor , , ' . �om ' , •• - r - vat sr ^�rwO^A NOCT:clrradiahce 800W/m2Ambient a Temperature 20°C _ Q' AM=1,5 Wind Speed 1m/s r s � MODULE DATASHEET - • .Power measurement tolerance: t 3%' • �' 5 , 25 Years DATE: 01.04.2017 The company reserves the final night for explanation on any of the information presented hereby. EN.JKM--r300M-60-PERC_1.0_rev2017 DESIGN BY: R.D. ] s. CHECKED BY: R.D. REVISIONS : A' B 43 , C l D E. 4. F D_1. A - B C ' - 1 2 3 I 5 i 6 The best choice for SolarEdge enabled systems - - Specifically designed to work with power optimizers - Integrated arc fault protection for NEC 2011690.11 compliance - - - - Rapid shutdown for NEC 2014 690.12 - Superior efficiency (98%) - Smell, lightweight and easy to install on provided bracket' ' - Built-in module -level monitoring - Internet connection through Ethernet or Wireless Outdoor and indoor installation - Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional - revenue grade data, ANSI C12.20 USA -CANADA -GERMANY -ITALY -'FRANCE-JAPAN-CHINA -AUSTRALIA- THE NETHERLANDS -UK -ISRAEL -TURKEY-SOUTH AFRICA -BULGARIA www.solaredge.us A B C - D E F G H so Jar 0 0 0. solar=oo c� SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / . 'SolarEdge Single Phase Inverters For North America -, SE3000A-US % SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE1000OA-US / SE1140OA-US SE3000A-US C= 5 i 6 The best choice for SolarEdge enabled systems - - Specifically designed to work with power optimizers - Integrated arc fault protection for NEC 2011690.11 compliance - - - - Rapid shutdown for NEC 2014 690.12 - Superior efficiency (98%) - Smell, lightweight and easy to install on provided bracket' ' - Built-in module -level monitoring - Internet connection through Ethernet or Wireless Outdoor and indoor installation - Fixed voltage inverter, DC/AC conversion only Pre -assembled Safety Switch for faster installation Optional - revenue grade data, ANSI C12.20 USA -CANADA -GERMANY -ITALY -'FRANCE-JAPAN-CHINA -AUSTRALIA- THE NETHERLANDS -UK -ISRAEL -TURKEY-SOUTH AFRICA -BULGARIA www.solaredge.us A B C - D E F G H - /(4J ��JA) SUr15PEC � .0 `� .• .. .• 1, - ... � - ' +><inrolla7p �fP•wwx9. rm 6nrwm�a-icR �c ;'n'.Im+>Isca wT- +1�BtP�r�W4z6k4t+1Gzila t ^ . '-. . E F - •. G - . H VILUMSOlLar ROBERT DEAN, ILUM SOLAR INC. 820 26TH ST. APT #6. SACRAMENTO, CA 95816 PHONE: (916) 905-0941 LIC. No.: 109260 INVERTER'DATASHEET DATE: 01.04.2017 DESIGN BY: R.D. CHECKED BY: R.D. REVISIONS . D-2 ' so Jar 0 0 0. Single Phase Invelrters-for North America SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US / SE7600A US / SE10000A US / SE11400A US - SE3000A-US I SE380OA-US I SESOOOA-US I SE6000A-US I SE76GOA-US I SE10000A-US SE1140OA-US f OUTPUT { Nominal AC Power Output 3000 .3800 5000 6000 7600 9980 @ 208V - 11400 VA " .......................p......;...:........ . " '' ............. ......... .......... ..:.......... 10000 240V .............. ..... Max. AC Power Out ut F"' 3300 5400 @ 208V 4150 6000 8350 10800 @ 208V 12060 VA ............................................ . ............................. 5450 �p 240y - , ............ ............ 10950 (1n 240V . ..... .. Output Voltage Min: Nom: Max."l t J OrAC 183 - 208 - 229 Vac - AC Output Voltage Min: Nom: Maz.10 ' V V 211- 240 - 264 Vac :.. ' ............................... AC:Frequency Min: Nom: Max.l'. ` . • .:....:......................... .., ................. ........ ........ . ...... ........:.. - - 59.3.-..6.0.-.6.0.S . .. .... . ......................... - . Hz Max. Continuous Output Current 12.5 24 @ 208V 16 25 32 48 @ 208V """"""" 47.5 A '............................................................ . 21 240V .................:.....42- ......Q° ...................... ............................. ,. GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes- Yes . '_INPUT 4' ' Maxlmum DC Power (STC) 4050 5100. 6750 8100 10250 13500 15350 W Transformerrvless, Ungrounded ........................................... ......................................................................' ..Yes Max. Input Volta e .........'.............................................................................................................:........................................... - 500 - Vdc ' Nom. DC Input Voltage 325 @ 208V / 350 @ 240V Max. InputCurrent"I.... 9.5......I 1 6.5 @ 208V 33 @ 208V ......13......I.15:?.@.240y.1......18.......I....... 23.......I..305@240V..I.......34.5..........Adc.... , Max. Input Short Circuit Current ...................................................................................................... 45 . -...-.................................. Adc Reverse -Polarity Protection ....Y ...:....:..:........:.'....:.. - - Yes + ' ........'............................ . -.......... ` Ground -Fault Isolation Detection 600ko Sensitivity ..i ............................ ....98 . ••..• ,.• ...%.. . Maxlmum Inverter EfficlencY.......... 97.7 98:?..... '......98:3...........98:3............ 98.-.'........... 98 CEC Weighted Efficiency 97'5 98 97 @ 208V 97.5 •97.5 .......... 97 @ 208V 97.5: 98 % ' 240V -. ., ,.97S,�1a 240V., .., ' Nighttime Power Consumption' <2.5 <4 W I ADDITIONAL FEATURES } Supported Communication Interfaces RS485, RS232, Ethernet, Zig8ee (optional) ...........................In....................................................:-..:.......... Revenue Grade Data, ANSI C12.20 ....................................................................................................................................:..................:........................ Optional Rapid Shutdown - NEC 2014 690.12 Yes 'STANDARD COMPLIANCE ). Safety :.........................................:......................................................... UL1741, UL17415A, UL1699B, UL1998 , CSA 22.2 ................................................. : .......... Grid Connection Standards . Iii E1547 ...................................................................... ., Emissions FCC part15 class 8 i INSTALLATION SPECIFICATIONS I. AC output conduit size /AWG range ................ ... ......... 3/4" minimum / 16.6 AWG ....................................................I....................... 3/4" minimum / 8-3 AWG DC input conduit size / ff of strings / 3/4" minimum / 1-2 strings / 16-6 AWG 3/4" minimum / 1-3 strings / • AWG rang?............:........................ ...........................................I............ - 14-6 AWG . .... Dimensions with Safety Switch 30.Sx12.Sx7.2/775x315x184 30.5. x 12.5 x 10.5 / in / HxWxD ....................... Wei ht with Safety Switch 51.2 / ...................._................ . ... �.. ...................... 23.2. 54.7 / 24.7. '.................................................................:........ .... :..... 775 x 315 x 260..... :. 88 .4 / 40.1 mm Ib / kg• ' Natural -' . convection Cooling Natural Convection and Internal ~. Fans (user replaceable) Y fan (user re laceable Noise' ...........................:................ ............................. <25 ............................... . '1................. -1, dBA'. < 1 Min: Maz. Operating Temperature -13 to +140 / -25 to +60 (40 to +60 version available(')) ...<S .... ................... .....-.. Range• ProtectiogRatinR,...............r. ......NEMA3R.:.. _ ru For other regional settings please contact SolarEdge support. , l - 101 A higher current source may be used: the inverter will limit Its Input current to the values stated. - pl - - Revenue grade Inverter P/N: SE-A-USOOONNQ.'+- 01d0 version P/N:SE­A-U5000NNU4 (for 760OW Invener:5E7E00A-U5002NNU4). - - • ; • - ` - /(4J ��JA) SUr15PEC � .0 `� .• .. .• 1, - ... � - ' +><inrolla7p �fP•wwx9. rm 6nrwm�a-icR �c ;'n'.Im+>Isca wT- +1�BtP�r�W4z6k4t+1Gzila t ^ . '-. . E F - •. G - . H VILUMSOlLar ROBERT DEAN, ILUM SOLAR INC. 820 26TH ST. APT #6. SACRAMENTO, CA 95816 PHONE: (916) 905-0941 LIC. No.: 109260 INVERTER'DATASHEET DATE: 01.04.2017 DESIGN BY: R.D. CHECKED BY: R.D. REVISIONS . D-2 ' 3 4 5 6 • e PV power optimization at the module -level Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses; from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt v Next geneiation maintenance with module -level monitoring Module -level voltage shutdown for installer and firefighter safety A - B C :.. E F G . SolarEdge Power Optimizersolar H - 3 4 5 6 • e PV power optimization at the module -level Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses; from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt v Next geneiation maintenance with module -level monitoring Module -level voltage shutdown for installer and firefighter safety 4 ., � 4� •- . - _ � •� .. -,t - sem. f` - , } =g@ . SolarEdge Power Optimizersolar Module Add -On for North America y P300 / P320 / P400 / P405 P300 P320 P400 . P405 /- - (for (tor fill•cell modules) high-power - (for 72 & 96 -cell • (for thin film t. •.� 60 -cell modules) modules) modules). iINPUT . • Rated Input DC Power<tl 300 320 400� :. - '405 ' W Absolute Maximum Input Voltage ......:;..�..:.................. 48 80_ ........... 125 ' Vdc r (Voc at lowest temperature) r - :.........:.....,..............:..............,.... - ....................... . r Operating Rang? ................ .:.:.:.................:............. 8.48 ' .12.5 -105 .... Vdc S' • , .;MPPT ............. Maximum hort Circui urrent Isc 5 t C ( ) ................................................................:..........:..............................:..................... ..........8.:80....... . 10 ( 11 - 10.1 Adc `r .Maximum DC Input Curren[ 12.5 13.75 12.63' Adc Maximum EHinenty:. ...................................'......:....:.............. ..................:...... 99:5 .. ....... ............................................. Efficien9 ............................. .....................................I............. 98.8. ................................................................:..................................... . % ... y. Overvolta a Category II .... I OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) f �� ,- Maximum0utputCurrent ....:...................................................... 15 ..... .... ............... Adc Maximum Output Voltage 60 85 Vdc 'J _ [OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) 1 Safety Output Voltage per Power 1 f Vdc.,• Optimizer I STANDARD COMPLIANCE 11 JEMC FCC Part15 Class B, IEC61000-6-2, IEC61000.6-3 ottY........... :.:................. .....:....:..............afet1UL3741 :.• IEC6210-1(casi sills .... .. . ..:....- RoHS Yes - -♦INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000Vdc ........... ............... r " • Compatible inverters .AII SolarE.dge Single Phase and Three Phase inverters'.- - .... ..... �. Dimensions (W x L x H) 128x 152 x 27.5 / 128 x 152 x 35 / 128 x 152 x 50 / mm / In' ..................................................................................................................................:......................................... Sx5.97x1.08 Sx5.97x1.37 Sx5.97x1.96 Weight (including cables)......:...............................760 / 1:............................... 830 /1:8................ 1064 / 2.3.:.........e;cl.lb.... . Input Connector ....................................................................... MC4 Compatible ......... _Output Wire Type /Connector .Double Insulated; MC4 Compatible ............................................ ., Out ut W Ire Len h P l3?... .. .....:... 0.9.5./.3.0 1.21.3.9 .................. .........:............. ........... m k .../....... Operatin&TemperatureRang? .................................... ••.:40 :+85/-40;+185 ....................................... C( F Protection Rating .... ....................: ..................IP68 /.NEMA6P...................... ........................................ ' Relative Humidity ...................................................................................................................... 0'-100 . ................. ...... w Hated SrC power o/the module. Macule of up to �5%power tolerance allowea. 1 ' 4 ., � 4� •- . - _ � •� .. -,t - sem. f` - , 3 4 5 6 A B - C D E F G H _ E"- Pitched industrial roofs ' Pitched industrial roofs EJOT __��`�- �i '�•�• _ Ali` - - dip ��;- • rte' �'' _.,,F � � �� �J .;s�'"' - ,• 47, Suitable for various applications depending on roof structure: r' JA3 thread for timber substructures: Solar Fastening Systems for pitched industrial roofs. ■ ■ ■ < The Solar Fastening System was the first stainless steel fastening element, building authorities approved by the DIBT (German Institute for Construction), to fix photovoltaic installations to trapezoidal steel profiles and sandwich panel roofs. The Solar Fastening System is also suitable for use on fibrous cement corrugated Frorra► ssaoxL Froraa3se aoa Fror fav sa ao=L sheet roofs. with with with FZD sealing Sealing washer El sealing washer El . 4 . - - - - for fibre cement root covering -+ ORKAN storm washer' ' + ORKAN storm washer . • - - The solar fastener Is directly fastened Into the for sandwich elements for trapezoidal sheet metal rafters, purlins or trusses of the substructure. Linear expansion of the joint, as well snow loads, JZ3 thread for steel substructures: can be absorbed in a lasting and reliable way. The roofing is not loaded and the number of roof perforations is minimised. For an existing roof the screws are simply EJOT solar Fastening system - -�- exchanged with a Soler Fastener. Using common - _ - adaptors the prominent thread is compatible For fastening elevated solar and photovolta c installations. with all rail systems and offers the possibility to - - With general dx7dv,g euttho itlees compensate differences in height. . approval Z-14.4-537 • - . EJor J73-SB-&OxL . EJnr JZ"P' 0XL , EJOr JZ&Sa•a.fhL '. ■V- withwith • Jwlth a FZD sealing sealing washer E16 sealing washer E78 for fibre cement mol covering . '+ ORKAN storm washer + storm washer r •. �' =_ L10 ORKAN .. ' for sandwich elements for trapezoidal sheet metal . s A B C D F F N 101LUMSOLa r i . ROBERT DEAN, ILUM SOLAR INC. -•820 26TH ST. APT #6. SACRAMENTO, CA 95816 PHONE: (916) 905-0941 LIC. N6.:109260 RACKING MOUNT - DATASHEET r' DATE:. 01.04.2017 " ' - DESIGN BY: R.D. r CHECKED BY: ' R.D. REVISIONS , M p_4 IRON RIDGE �' _ XR Rail Family _,XR Rail Family • t ` k �` '`• ;' ' : ' •, The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific 'Solar Is Not Always Sunnydesign loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. ' f Over their lifetime, solar panels experience cotintless extreme weather events. Not Just the worst storms In years,- but ears;but the worst storms in 40 years. High winds capable of .-ripping panels from a roof, and snowfalls weighing' "`f---`--�•"�'—'j . enough to buckle a panel frame. XR Rails are the structural backbone preventing y 4 �- v these results. They resist uplift, protect ® XR10 XR100 XR1000 against buckling and safely and efficiently " • - transfer loads into the building structure. ® • XR10 is a sleek, low -profile mounting XR100 is the ultimate residential XR 1000 is a heavyweight among rail, designed for regions with light or mounting rail. It supports a range of solar mounting rails. It's built to handle Their superior spanning capability�/� -�® • . no snow. It achieves 6 foot spans, while wind and snow conditions, while also extreme climates and spans 12 feet or requires fewer roof attachments, f�/� r� remaining light and economical. maximizing spans up to 6 feet. more for commercial applications. reducing the number of roof 6'spanning capability 8'spanning capability 12'spanning capability penetrations and the amount ( ✓ .{ �.r ,., �``]] � , Moderate bad capability Heavy load capability Extreme load capability of installation time. lh Clear anodized finish Clear &black anodized finish Clear anodized finish Internal splices available Internal splices available Internal splices available ' �• ;� ®� Rail Selection' The following table was prepared in compliance with applicable engineering codes and standards. Values are ' • *j� based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean - '�!`,' Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications.. Force -Stabilizing Curve Sloped roofs generate both vertical and lateral r forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails Is specialty designed to increase strength In both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. _ A. g C p E' • F _ H. _ A g C p E F G H IRON RIDGE �' _ XR Rail Family _,XR Rail Family • t ` k �` '`• ;' ' : ' •, The XR Rail Family offers the strength of a curved rail in three targeted sizes. Each size supports specific 'Solar Is Not Always Sunnydesign loads, while minimizing material costs. Depending on your location, there is an XR Rail to match. ' f Over their lifetime, solar panels experience cotintless extreme weather events. Not Just the worst storms In years,- but ears;but the worst storms in 40 years. High winds capable of .-ripping panels from a roof, and snowfalls weighing' "`f---`--�•"�'—'j . enough to buckle a panel frame. XR Rails are the structural backbone preventing y 4 �- v these results. They resist uplift, protect ® XR10 XR100 XR1000 against buckling and safely and efficiently " • - transfer loads into the building structure. ® • XR10 is a sleek, low -profile mounting XR100 is the ultimate residential XR 1000 is a heavyweight among rail, designed for regions with light or mounting rail. It supports a range of solar mounting rails. It's built to handle Their superior spanning capability�/� -�® • . no snow. It achieves 6 foot spans, while wind and snow conditions, while also extreme climates and spans 12 feet or requires fewer roof attachments, f�/� r� remaining light and economical. maximizing spans up to 6 feet. more for commercial applications. reducing the number of roof 6'spanning capability 8'spanning capability 12'spanning capability penetrations and the amount ( ✓ .{ �.r ,., �``]] � , Moderate bad capability Heavy load capability Extreme load capability of installation time. lh Clear anodized finish Clear &black anodized finish Clear anodized finish Internal splices available Internal splices available Internal splices available ' �• ;� ®� Rail Selection' The following table was prepared in compliance with applicable engineering codes and standards. Values are ' • *j� based on the following criteria: ASCE 7-10, Roof Zone 1, Exposure B, Roof Slope of 7 to 27 degrees and Mean - '�!`,' Building Height of 30 ft. Visit IronRidge.com for detailed span tables and certifications.. Force -Stabilizing Curve Sloped roofs generate both vertical and lateral r forces on mounting rails which can cause them to bend and twist. The curved shape of XR Rails Is specialty designed to increase strength In both directions while resisting the twisting. This unique feature ensures greater security during extreme weather and a longer system lifetime. _ A. g C p E' • F _ H. 2 3 . 4 5 6 A B C D E F' G H r _' //d IRONRIDGE UFO Family. of Components t System Diagram Simplified Grounding for Eve Application 9 Every PP y r _ �� #�_ _•`% fit_ ,. : r_-� .i .1 �i� s'_��!s ,P r r ;c tt =i► _tc- 1}. wF r7 .. t .« _ ----- ~ - The UFO family of components eliminates the need for _ N/A �, �' `: sx E ,: r7 -�, i :rte :t• Microinverters & Power Optimizers Enphase = M250-72, M250-60, M215-60, C250-72, Darton - MIG240, MIG300, G320, G640 SolarEdge - P300, P320, P400, P405, P600, P700, 12730 Class A Class A • WA r separate grounding hardware by bonding solar modules �Iltta• !� {• ', i# 1 ( tr y '►' '� ,w to IronRid a XR Rails. All system types that feature _•I_`.�1 �r •�+ ,� N -1i% .. t•- -t) :, , , tx..- .directly the UFO family—Flush Mount, Tilt Mount and Ground,- Mount—are fully listed to the UL 2703 standard. it: R- r •r t�_ �_r t x=-'��H' �% +- r �r r ^ -�r--+�--� n St r1 ,rxt i=- ' t�_ xa to _,). -... ?. - F UFO hardware forms secure electrical bonds with both the _ (� _ ;; r iy _ r 4.- module and the rail, resulting in many parallel grounding { _, t..,. � t. l : _! .�. � . tt_:tJ ., �. 'r - ' - ! �1. " Ll paths throughout the system. This leads to safer and more 'y�77. . r , reliable installations. r +lr �_' _.f `t q ��` ". �� r ` :t7� fr ' t 171 t _ir ., -TY +_ .u� r - i _ �:� t � Y= � EQ)-�- :F-�3.-[}, :. - -nF} i:_ _LF-T-1,p- : --------- ;L 'i " ---n7 _R ]l 0 .htr .- .rS Sleeve Universal Fastening Object (UFO) i ` Stopper Sleeve snaps The UFO secure) bonds solar modules to XRThe 1'7 �� " r onto the UFO, converting it Into a bonded end clamp. Rails. It comes assembled and lubricated, and ' can fit a wide range of module heights. _i ^�• _� ! *"_+r _moi't. ? n- `-L� ;Y - T�r`t�i __ m _a z _ _ r .tet_ •' M _rtTv_^_= +� �f`^_ _ Ott r �Jt t SC k }L J 1's is a r 4 Approved Enphase microinverters can provide equipment grounding of IronRidge systems, eliminating the need for `.� grounding lugs and field installed equipment ground conductors (EGC). A minimum of two microinverters mounted to the - _ same rail and connected to the same Engage cable is required. Refer to installation manuals for additional details. r . UL Certification The IronRidge Flush Mount, \ ' Tilt Mount, and Ground Mount Bonded Splice r r . r�r' ; Systems have been listed to UL J �A Each Bonded Splice uses 2703 by Intertek Group plc. self -drilling screws to form _6 11 a secure connection. No , bonding strap needed. r JJJ UL 2703 is the standard for •��`��"�'� evaluating solar mounting ` systems. It ensures these devices l will maintain strong electrical and Grounding Lug "rf mechanical connections over ®� n single Grounding Lug Bonded Attachments connects an entire row The bonding bolt attaches ' an extended period of time in of PV modules to the and bonds the L -root to the extreme outdoor environments. grounding conductor. rail. It Is installed with the same socket as the rest of the system. 0 Go to IronRidge.com/UFO i 611LUMSdLar ROBERT DEAN, ILUM SOLAR INC. 820 26TH ST. APT #6. SACRAMENTO, CA 95816 PHONE: (916) 905-0941 LIC. No.: 109260 - INTEGRATED GROUNDING DATASHEET DATE: 01.04.2017 DESIGN BY: R.D. -CHECKED BY: R.D. REVISIONS XR Rails r _ XR1000 Only, UFO/Stopper V Bonded Splice .r .� `.� N/A Grounding Lugs 1 per Row 1 per Row 1 per Array Microinverters & Power Optimizers Enphase = M250-72, M250-60, M215-60, C250-72, Darton - MIG240, MIG300, G320, G640 SolarEdge - P300, P320, P400, P405, P600, P700, 12730 Fire Rating Class A Class A • WA r Modules Tested or Evaluated with over 400 Framed Modules ' Refer to installation manuals for a detailed list. i 611LUMSdLar ROBERT DEAN, ILUM SOLAR INC. 820 26TH ST. APT #6. SACRAMENTO, CA 95816 PHONE: (916) 905-0941 LIC. No.: 109260 - INTEGRATED GROUNDING DATASHEET DATE: 01.04.2017 DESIGN BY: R.D. -CHECKED BY: R.D. REVISIONS ` 1 +, i.2 J .i.� - .Y•,• I � , S 1 � h `I _ � J � � ;, . ', 3 �` •4 �.5 i ' c�: e. 6 a • " f - y .F! win CM ..11 • .2.3.2 Fixation with Clampsat long sides of frames _, ` - _ - ;. ' ' '• ^. _ ' 4 Fringe matule4 iusmUntiou , Glnmp Friiwc (Ione side) Middle modtdes instuUitioat - ' The applicable Productsplease refer to Table 2, and only allow using clamps at long side of frames. _ The module clamps should not come into contadwith-the front glass and must not deform the frame.'Be sure to avoid shadowing effects from the module.clamps. The - a . . .. • - .. - .', i •. •-'Molmtille mil MBSCfetY .module .frame is not to be modified'Under any.circumstances. When choosing this _ - type of clamp -mounting method; please,be sure to use at least four clamps on each ` ule i Figure 3: hV'mod Installed at long de of with Clamp fitting method .module; two clamps should be attached on each long sidesof.the module. Depending i on the local, wind and snow loads, if excessive pressure load is expected, additional: clamps or support would be required to ensure .the module can bear. the load. The' applied torque should be big enough to fixit steadily (about 8 Nm.) , for safety, you'd better follow the clamps manufacture's recommendation: Please find detailed mounting information -in the '.below 'illustration, the mounting place distance is suggested_ bigger than J. and less than K; as shown below. 1) Normal IRV module (et long side): The movement of the. monnting tail and. the clamps center line are recommended to be within the black arrow area. ' Q ' - Clamp Moubtiq railA Ll ' 'Cell Cell Pmax; Dimension(mm)Mo ' - dule type type . 4uantity' (Wp} AM J . K Frame : 15804'804 300. 400 30'20 & 35'25&40'20 INSTRUCTION. y r• - DATE 0104 2017 30'20 &35.25 835'35. JKMSXXXM-72 5 inch 6'12 160-215 JKMSXXXM-72- J Mono -,CHECKED BY: R.D. A B C D & 40'30 & 40'35 & . E.. F G H _. win CM ..11 • .2.3.2 Fixation with Clampsat long sides of frames _, ` - _ - ;. ' ' '• ^. _ ' 4 Fringe matule4 iusmUntiou , Glnmp Friiwc (Ione side) Middle modtdes instuUitioat - ' The applicable Productsplease refer to Table 2, and only allow using clamps at long side of frames. _ The module clamps should not come into contadwith-the front glass and must not deform the frame.'Be sure to avoid shadowing effects from the module.clamps. The - a . . .. • - .. - .', i •. •-'Molmtille mil MBSCfetY .module .frame is not to be modified'Under any.circumstances. When choosing this _ - type of clamp -mounting method; please,be sure to use at least four clamps on each ` ule i Figure 3: hV'mod Installed at long de of with Clamp fitting method .module; two clamps should be attached on each long sidesof.the module. Depending i on the local, wind and snow loads, if excessive pressure load is expected, additional: clamps or support would be required to ensure .the module can bear. the load. The' applied torque should be big enough to fixit steadily (about 8 Nm.) , for safety, you'd better follow the clamps manufacture's recommendation: Please find detailed mounting information -in the '.below 'illustration, the mounting place distance is suggested_ bigger than J. and less than K; as shown below. 1) Normal IRV module (et long side): The movement of the. monnting tail and. the clamps center line are recommended to be within the black arrow area. ' Q ' - Clamp Moubtiq railA Ll ' 'Cell Cell Pmax; Dimension(mm)Mo ' - dule type type . 4uantity' (Wp} AM J . K Frame : 15804'804 300. 400 30'20 & 35'25&40'20 INSTRUCTION. y r• - DATE 0104 2017 30'20 &35.25 835'35. JKMSXXXM-72 5 inch 6'12 160-215 JKMSXXXM-72- J Mono -,CHECKED BY: R.D. 1580'808 300 400. & 40'30 & 40'35 & . ' 45'35 & 50'35 JKMSXXXM-96 5 inch 1580'1060' 280'1400 .. 40'30 & 40'20 REVISIONS 40'20 & 4W30 & 45'35 1JKMSXXXM-961• 8.12 210•-280 Mono 1575'1082. 280 400- '.to & 50.35 JKMSXXXP-60 . ' 35'25 & 40'20. & 40'30 JKMSXXXP-60 J 6 inch ri A` B.. to C, . D., . E 210-280 1650'992 280' 420 & 40'35 & 45.35 & JKMSxxxP-6014 Poly - ' 4KMSnxP-60(Ples) 50'35 JKMSXXXM-6035'25 & 40'20 8.40'30 ' 6 inch JKMSXXXM-60-J 6.10 210.x280 1650'992,. 280. 420. &.40'35.81 45'3.5 & Mono JKMSxxxM-60(Plus) 50'35, JKMSXXXP-72 . JKMSXXXP-72-J 6 inch ' 40'20 & 40'30 & 50'35 6'12 250•-335 1956.992 280 480 ' JKMSxxxP-72- J4. Poly & 40`35 •JKMSxxnP-72(Plus); JKMSXXXM-72 6 inch 40.20 & 40'30 & 50.35 .:JKM8XXXM-72-J 6'12 250•-335 1956.992 280 480 ' JKMSxxxM-72(Plus) Mono & 90'35 6 inch ' JKMSxxxP-60L•, Quasi-" . '6.* 10 215-275 _ 1650'992 280 420. 35`25 &40'30 & 40'35 mono ' JKMSXXXP-12L' inch 6.12 • 255•-330 1956'992 280 480, 40'30 & 40'35 "^ Y -14- : MODULE INSTALLATION. - INSTRUCTION. y r• - DATE 0104 2017 -14- : - DESIGN BY: R.D. trt -,CHECKED BY: R.D. REVISIONS ri A` B.. to C, . D., . E .. F G H - r A' B C ` D JKMSxx'xM48-J' JKMSzjaM48(Plus) 6 inch Mono 6'8; l 170.-220 - 1324'992. 240 270 40'35 JKMxxxP-48 E F. G - H JKMSxx'xM48-J' JKMSzjaM48(Plus) 6 inch Mono 6'8; l 170.-220 - 1324'992. 240 270 40'35 JKMxxxP-48 - JKMxrotPP48 ^ • 6 Inch JKMxxxPP-48-J4- 6'8 X170-•225 1324'992 240 270 4.0.35 Pol y JKMxxxPP-481 'JKMxxxPP-48(Plus) JKMSxxxP-48;1 JKMSxxx!2 4844. 6Inch . 6'8 170-225 1324'992' 240 270 40.35 Poly 1JKMSxxxP-48(Plu5!) • Frulgc li,alulcs' uisrnllntiou Clninp'' Frame (Imle-side) '" Middle Iiiodulcs instnllmnioi .. - A_A p T'I01111III1� tnll - MsscreW '� ,'� 4 • ' #► Figure 4: 'Ught PV module installed at long side with Clamp fitting.method Max. Pressure: 5400Pa mechanical load' s' Table 2: Mechanical dimensions when modules Installed at long side with Clamp fitting method ' 2) Light PV module: : Dlmenslon (mm`mm) ; Longer Frame Section: 28'6:9 Short Frame Section: 28'15 Beam Section: 19.15