Loading...
HomeMy WebLinkAbout001-220-038BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) :530.538.4365 (Cut off time for inspections is Spm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530 Permit No: B 17-2467 Issued: 10/17/2017 APN: 001-220-038 Address: 3240 4TH ST, BIGGS Owner: COMMUNITY HOUSING IMPROVEMENT Permit Type: SOLAR ROOF -RES Description: 4.8 KW roof mount solar As2s.1 ia:) www.fiuiteuounty.net/aas AREA 1 Flood Zone: None SRA Area:. No SF.TRACKS for Zoneno- AG_ SRA_ PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING In's ection TvDe WR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122. Eufer Ground 216 Masonry Grout 120' Setbacks 131 Do Not Pour Concrete Until Above are Sign d Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412' Under Slab Plumbing 411 - Blockin nder inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129. Manometer Test 605 Do Not Install Siding/Stucco or Roofin Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Inspection Tyve IVR INSP DATE T -Bar Ceiling 145 Stucco Lath -142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nder inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Ski rtin Ste s/Landin s 610' Coach Info .Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL -rroject rinai is a cernucate of Vccupancy for (Kesidenual Vnly) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION and the manufacturer's installation Instructions. Other carbon monoxide alarm and devices as recognized in NFPA 720 are also acceptable. Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be Installed in following locations: 1. Outside of each separate dwelling unit sleeping area in tate Immediate vicinity of the bedroom(s). 2. On every level of a dwelling unit including basements. R315.3.1 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke shall comply with Section R315, all applicable standards, and requirements for listing approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2010 CRC, Sections 394 & 315 for Smoke Alarms & Carbon Monoxid® Alanns: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be mtrofittod with smoke alarms and those lbg hue agadW gmum. or fue)--hurnini"igaM shalt have carbon monoxide alarms installed. Existing smoke atoms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requii ements ms for Carbon Monoxide Alar. DECLARATION OF INSTALLATION UNDER THE PENALTY OF As Owner/Contractor, Uwe affirm and declare, under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that liwe will comply prior to final Inspection with items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm mquirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final Inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will also be Installed prior to final inspection as per the 2010 CRC. Smoke and Carbon Monoxide alarms are now installed In the folloWng locations; - At_.l_ 5CrV_'GV,4 o.re'r- -k 15C..-•oe—r � CJD t0 kfNLL1A,3P1'( Owners name (print): U Owner's Contractor's name (print): S� �A�� r'�� �R� CSLB License: One I o -i- Contractor's signature:�� r Date: kill- i (Z -D I-11 Project Address: 52A G `Cw ^�'1 I l�; � Permit #: -r Page 2 of 2 !' ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES 'A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET—BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 313 NEMA 3R, RAINTIGHT LICENSE CA # 888104 C-10 . MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: Butte County 1. THIS SYSTEM IS GRID—INTERTIED VIA A UL—LISTED POWER—CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY—RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE U.L—LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. GENERAL NOTES 1. ALL WORK TO BE DONE TO THE 2016 CALIFORNIA BUILDING CODE, 2016 CALIFORNIA PLUMBING CODE, AND THE 2016 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRIC CODE AS AMENDED BY THE.:2016 CALIFORNIA ELECTRIC CODE. 3. CFC 2016 4. SMOKE AND CARBON MONXIDE DETECTORS REQUIRED. UTILITY: Biggs Electrical Department COVER SHEET CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: JB -9597489 00 CONTAINED SHALL NOT BE USED FOR THE SITE PLAN MOUNTING SYSTEM: [MODULES: BENEFIT OF ANYONE EXCEPT TESLA INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert PART TO OTHERS OUTSIDE THE RECIPIENTS (16) TRINA SOLAR # TSM-300DD05A.1 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SAIF AND USE of THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF TESLA INC. ABB # PVI-3.6—OUTD—S—US—Z—A PREMISE OWNER: LINDA MILSTEAD 3240 4TH ST BIGGS, CA 95917 APN: * VICINITY MAP Linda Milstead RESIDENCE 4.8 KW PV ARRAY PAGE NAME-- COVER AMECOVER SHEET INDEX PV1 COVER SHEET PV2 PROPERTY PLAN PV3 SITE PLAN PV4 STRUCTURAL VIEWS PV5 UPLIFT CALCULATIONS PV6 THREE LINE DIAGRAM Cutsheets Attached REV BY DATE COMMENTS I REV A NAME I DATE COMMENTS EaaN: Jonathan Chavez T 5 L n WEE. REV: DATE PV 1 9/6/2017 4% (E) ORFVEWAY j f PROPERTYPLAN N ` Scale:l" = 20'-0' W E p 20' 40' - S CONFIDENTIAL - THE INFORMATION HEREIN ,OB NUMBER: JB -9597489 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE LINDA MILSTEAD BENEFIT OF ANYONE EXCEPT TESLA INC., NOR MOUNTING SYSTEM: Linda Milstead RESIDENCE Jonathan ChOVBZ _ 5 L n 'SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 3240 4TH ST 4.8 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES BIGGS CA 95917 THE SALE USE OF (16) TRINA SOLAR # TSM-300DD05A.18(II) TESLA EQUIPMENT, WITHOUT THE WR:RITTEN INVERTEPACE NAME SHEET: REV DATE PERMISSION OF TESLA INC. ABB # PVT-3.6-OUTD-S-US-Z-A PROPERTY PLAN PV 2 9/6/2017 " PITCH: 25 ARRAY PITCH: 25 MP1 AZIMUTH: 179 ARRAY AZIMUTH: 179 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 25 ARRAY PITCH: 25 MP2 AZIMUTH: 89 ARRAY AZIMUTH: 89 MATERIAL: Comp Shingle STORY: 1 Story • .' O Inv . ' • cri (E) DRIVEWAY / • - / / / ® LEGEND wj Q (E) UTILITY METER & WARNING LABEL TI INVERTER W/ INTEGRATED DC DISCO Inr F / zE`) B & WARNING LABELS r ir ocgg DC DISCONNECT & WARNING LABELS / / / / • \ \ © AC DISCONNECT & WARNING LABELS \ \ DC JUNCTION/COMBINER BOX & LABELS ,.a 1 \�\6�6\�\ DISTRIBUTION PANEL & LABELS Front Of House / / 'yj / \ S� �\ \ �� LOAD CENTER & WARNING LABELS DEDICATED PV SYSTEM METER RAPID SHUTDOWN Q STANDOFF LOCATIONS A CONDUIT RUN ON EXTERIOR L --- CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED SITE PLAN N Scale: 1/8" = 1', w E - 0 11 8, 16' 151 Mimi S CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR JOB NUMBER: JB-9597489 O 0 PREMISE OWNER: LINDA M I LSTEAD DESCRIPTION: Linda Milstead RESIDENCE DESIGN: Jonathan Chavez T S' L MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert - 3240 4TH ST 4.8 KW PV ARRAY � f" i PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH BIGGS CA 959 17 MODULES THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT;WITHOUT THE WRITTEN (16) TRINA SOLAR # TSM-30ODD05A.18(II) PAGE NAME SHEET: REV DATE INVERTER: ABB # PVI-3.6–OUTD–S–US–Z–A PERMISSION OF TESLA INC. SITE PLAN . PV 3 9/6/2017 MP1 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 241' 39" 64" 011 0" PORTRAIT 48" 2011 TOP CHORD 2X4 @ 2411 OC - BOT CHORD 2X4 @24" OC ROOF AZI ARRAY AZI 179 PITCH 25 STORIES: 1 179 PITCH 25 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 2411 39" 64" 0" 011 PORTRAIT 4811- 2011 TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @2411 OC ROOF AZI ARRAY AZI 89 PITCH 25 STORIES: 1 89 PITCH 25 Comp Shingle X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV. X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS. - PV MODULE • 5/16"x1.5" BOLT WITH 5/16" FLAT WASHER - INSTALLATION ORDER ZEP LEVELING FOOT _ LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT HOLE. ZEP MOUNTING BLOCK --------- — ———— —— — — —— ATTACH FLASHING INSERT TO (4) (2) OUNTING BLOCK AND ATTACH ZEP FLASHING INSERT (3) TIO RAFTER, USING LAG SCREW. (E) COMP. SHINGLE , (1) INJECT SEALANT INTO FLASHING (E) ROOF DECKING (2) (3) INSERT PORT, WHICH SPREADS ' SEALANT EVENLY OVER THE ' 5/16" STAINLESS ROOF PENETRATION. _ ,DIA STEEL LAG SCREW LOWEST MODULE SUBSEQUENT MODULES (2-1/2" EMBED, MIN) INSTALL LEVELING FOOT ON TOP C(4) OF MOUNTING BLOCK & (E) RAFTER SECURELY FASTEN WITH BOLT. #__STAN CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT TESLA INC., NOR JOB NUMBER: JB -9597489 00 PREMISE OWNER: LINDA M I LS TE A R 'ST DESCPoPRON: Linda Milstead RESIDENCE DESIGN: Jonathan Chavez � T= 5 L MOUNTING SYSTEM: SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 w Flashing—Insert 3240 4TH 4.8 KW PV ARRAY n PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES BIGGS CA 95917 , THE SALE AND USE OF THE'RESPECTIVE (16) TRINA SOLAR # TSM-30ODD05A.18(II) TESLA EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE: - PERMISSION OF TESTA INC. ABB # PVI-3.6—OUTD—S—US—Z—A STRUCTURAL VIEWS PV. 4 9/6/2017 1 - DESIGN. SUMMARY. ' 09 06:2017` ver9ion ' ` ' " ;JobsiteS ecific Design Cciteria� 4 ' 'D�esion Code INVERTER:PAGE ABB PVI-3.6-OUT0—S-US-Z-A ASCE 7=10 ' 1. . f - i �� 1 S Ultimate Wintl Speed; • lV . V Ult:. 110 mph' • r . .. (5 Ir Category. _ C ;'�Section2fi7 Ground Sr OW -Load: ASCE Table 7=1 �lpg ... .. --r • - - ..ra, MP.:S"ecificrDesi`n nf6e iation' �.� MP NaiveMpl r-MP2 c Rooting " ; Comp Root 'Comp Rooth s Standoff" 666ip:M66`nt.SRV CompNlouriiSRV �.' P.iteh: ' :26'.4 26' - _ - m•. SLIIRLL -PV �' zSLIRLL xNon, PV ![ 18:5! _sf18i6ipsl iStani ofF'S acin and La. out . `~ _ MP Name MP1 MP2" { m. X Spacln9 . 372"•" 72" r _ X -Cantilever 24'• 24'% t � .. Y=CanMeverIiNA; NA .r + 48" •r X -Cantilever... 2O'` 20" , ' . .. ' i i , . �:" t• , + YCantilever . ' NA, t s . �ry 4: 1 r a . � * ' 2 Y' • ' , .. ; .. !+ _fes, �'' -S-'. - 4r: + .•.. `-. .. ty .-. - by �^ ,�• }}, •, •�•`�- ., f 1. .�., " `l + - 71 • ••- • ` r + � r.• ' � � [,•.. `. n ', '' • •.a r' f. . • . . �` 4.y». • • � .` , ,•i [{., .; . ... , tr; [`ir 4"I •r ` ` r_ 1. ' � � • " Y.. � i ` � ' a° - �. ',. r •� ,r � Y, it - .L r - {' 3� ^ ,, .. , - , `r , [ .. � •� • .,. .rte^' � i � ,. �,t. � [' • °`"` .. �_• r �' �' .. ,� • r.f ,f '.1 '�r i. d G t "''•t W3 a' +, `F:1. �. N - �. / 1. a. , � •k.'i.Q+ ! i - ' • i . , e ', " J'. �a� a Ji - � { s � : .. ;.C` J f• ry, :. C . � ". � : .. . , • . - r .. ..r. ' '' '� � - DESIGN. SUMMARY. ' 09 06:2017` ver9ion ' ` ' " ;JobsiteS ecific Design Cciteria� 4 ' 'D�esion Code INVERTER:PAGE ABB PVI-3.6-OUT0—S-US-Z-A ASCE 7=10 Importance Factor � ._.._. Ultimate Wintl Speed; • V Ult:. 110 mph' Fig t1609A , (5 Ir Category. _ C ;'�Section2fi7 Ground Sr OW -Load: ASCE Table 7=1 �lpg ... .. --r • - - ..ra, MP.:S"ecificrDesi`n nf6e iation' �.� MP NaiveMpl r-MP2 c Rooting " ; Comp Root 'Comp Rooth s Standoff" 666ip:M66`nt.SRV CompNlouriiSRV �.' P.iteh: ' :26'.4 26' - _ - m•. SLIIRLL -PV �' zSLIRLL xNon, PV ![ 18:5! _sf18i6ipsl iStani ofF'S acin and La. out . `~ _ MP Name MP1 MP2" { m. X Spacln9 . 372"•" 72" r _ X -Cantilever 24'• 24'% .. Y=CanMeverIiNA; NA X _ . S eg _ X48"` 48" X -Cantilever... 2O'` 20" Y_S�.-clog YCantilever . ' NA, NA .a 1 y Not; eted fNotSta ""efed:* -R and Y ariim jniums Ithat`are: ahva s relative to the WUcture frari iirithatsu orts the PV,: X'is-acrossta8ers-and°Y is lion 'raftets.. ' c - DESIGN. SUMMARY. ' 09 06:2017` ver9ion ' ` ' " ;JobsiteS ecific Design Cciteria� 4 ' 'D�esion Code INVERTER:PAGE ABB PVI-3.6-OUT0—S-US-Z-A ASCE 7=10 Importance Factor � ._.._. Ultimate Wintl Speed; • V Ult:. 110 mph' Fig t1609A , (5 Ir Category. _ C ;'�Section2fi7 Ground Sr OW -Load: ASCE Table 7=1 �lpg ... .. --r • - - ..ra, MP.:S"ecificrDesi`n nf6e iation' �.� MP NaiveMpl r-MP2 c Rooting " ; Comp Root 'Comp Rooth s Standoff" 666ip:M66`nt.SRV CompNlouriiSRV �.' P.iteh: ' :26'.4 26' - _ - m•. SLIIRLL -PV �' zSLIRLL xNon, PV ![ 18:5! _sf18i6ipsl iStani ofF'S acin and La. out . `~ _ MP Name MP1 MP2" { m. X Spacln9 . 372"•" 72" r _ X -Cantilever 24'• 24'% .. Y=CanMeverIiNA; NA X _ . S eg _ X48"` 48" X -Cantilever... 2O'` 20" Y_S�.-clog YCantilever . ' NA, NA .a 1 y Not; eted fNotSta ""efed:* -R and Y ariim jniums Ithat`are: ahva s relative to the WUcture frari iirithatsu orts the PV,: X'is-acrossta8ers-and°Y is lion 'raftets.. ' CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE ' B ANYONE EXCEPT TESLA INC., NOR 9tALL IT BE olsaosED IN WHOLE OR IN SHALL PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN OF TESLA INC. JOB NUMBER: J B-9597489 00 PREMISE OWNER: DESCRIPTION: LINDA MILSTEAD • Linda Milstead .RESIDENCE 3240 4TH ST. 4.8 KW -PV ARRAY ; •+ y BIGGS, CA' 95917 NAME �. UPLIFT CALCULATIONS i •. ' MOUNTING SYSTEM: ZS Comp V4 w Flashing—Insert 7SHEEU�T-., 4 CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE ' B ANYONE EXCEPT TESLA INC., NOR 9tALL IT BE olsaosED IN WHOLE OR IN SHALL PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE TESLA EQUIPMENT, WITHOUT THE WRITTEN OF TESLA INC. JOB NUMBER: J B-9597489 00 PREMISE OWNER: DESCRIPTION: LINDA MILSTEAD • Linda Milstead .RESIDENCE 3240 4TH ST. 4.8 KW -PV ARRAY ; •+ y BIGGS, CA' 95917 NAME �. UPLIFT CALCULATIONS T 1 5 L n MOUNTING SYSTEM: ZS Comp V4 w Flashing—Insert 7SHEEU�T-., MODULES (16) TRINA SOLAR # TSM-300005A.18(II) E•PERMISSION /6/2017 INVERTER:PAGE ABB PVI-3.6-OUT0—S-US-Z-A GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #6 GEC TO (N) GROUND ROD AT PANEL WITH IRREVERSIBLE CRIMP Panel Number: NoMatch Meter Number: 74044683 Inv 1: DC Ungrounded INV 1 — (1) ABB PVI-3.6—OUTD—S—US—Z—A BEL: A AFCI nverter; ZB,360OW; 277V/240V%208V, 967./967./96%,IntgrtdPwrSupply,R21 — (16) TRINA SOLAR TSM-300DD05A.18 II PV Module; 30A,270.6W PTC,40MM, k Frame,MC4,ZEP,1000V,Wht BckSht CA # 888104 C-10 Underground Service, Entrance _ INV 2 Voc: 39,9 Vpmax: 32.6 5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER ` �E 125A MAIN SERVICE PANEL E; 10OA/2P MAIN CIRCUIT BREAKER ABB ADJUST MIN. ACTIVATION VOLTAGES! - RSD-Kit Inverter 1 IND 100A/2P _ 5 ABB a 1 . Dc+ VStai't = 200V PVI-3.6—OUTD—S—US—Z—A DC- MP2:1X8 (E) LOADS EGc u x4av �.---------------------------------- - -------------tpj L2 DC • 20A/2P —--——————————— jA F1- —————————— ———— _EGC DC+ I 3 2Dc+ VStart = 200V r-- ' ——— —————————— — — — — —— :— N DG ` MP1�1 8 X ------—-- ---------—--- -------— - - - -- -- - GECGND EGC-GC --- r----- -- -- __ -------- - - - — -- ------ - -- -- - ----J (1) CQrIDUIT KIT j I < , � 1 z 10' EMT Conduit N , a' p EGC I J • „ GEC I T---- — — — — — t - - TO 120/240V SINGLE PHASE UTILITY SERVICE Voc* = MAX VOC AT MIN TEMP O1 (1 )CUTLER-HAMMER I BR220 PV BACKFEEO BREAKER Bryeaker, 20A/2P, 2 Spaces �� A (2)ABB RS1-1PN6-MC4 3P029960000A RSD it; ZEP, MC4, NO Power Supply DC -(1)Gr7"d R8 Cap per 1 AWG #10, THWN-2, Block 5O Isr (1)AWG #10, THWN-2, Red -(I AWG #5, Solid Bare Copper GEC (2)AWG #10, PV Wire, 60OV, Black Voc* = 352.52 VDC Isc = 9.64 ADC O (1) AWG /10, Solid Bare Copper EGC Vmp = 260.8 VDC Imp= 9.19 ADC PF (2)AWG #10, PV Wire, 60OV, Black Voc* = 352.52VDC Isc = 9.64 ADC .O (1)AWG #10, THHN/THWN-2„ Green EGC Vmp = 260.8 VDC Imp= 9.19 ADC ` LLL (1) AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp =16 AAC . . (1 ) AWG 1!8.,.2. conductor, ... SIGNAL . •- 0 )Conduit, Kit; • 3/4' .EMT. (1 Conduit Kit; 3 4- EMT -,(1)AWG #1Q T11WN-2,.Gre�_ . EGC , . , ,-(1)Conduit. Kit;. 3/4'.EMT. • , . • .. • . , (2)AWG 110, PV Wire, 60OV, Bladc Voc* = 352.52VDC Isc = 9.64 ADC ® (1)AWG 110, Solid. Bare Copper EGC Vmp = 260.8 VDC Imp= 9.19 ADC (2 (()AWG 0, PV Wire, 600V, Bladc Voc* = 352.52 VDC Isc = 9.64 ADC O V (1) AWG 0, THHN/THWN-2, Green • EGC Vmp = 260.8 VDC Imp= 9.19 ADC i ....... (1)Conduit Kit;. 3/4'. EMT (1)Conduit Kit;. 3/4' EMT...........'........... ......... ....... CONFIDENTIAL -, THE INFORMATION HEREIN JOB NUMBER:J B-9 5 9 7 489 00 PREMISE OWNER: DESCRIPTION: DESIGN: - CONTAINED SHALL NOT BE USED FOR THE NOR LINDA MILSTEAD Linda IPVeARRAY RESIDENCE Jonathan Chavez T 5 L MourinNc sYsrEu: SBENEFIT HALL ITOBE DISCLOSEDIN wHOLE OR IN ZS Comp V4 wFlashing-Insert ` 3240 4TH ST 4.8 KW n PART TO OTHERS OUTSIDE THE RECIPIENT'S BIGGS, CA 95917 MODULES ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-30ODD05A.18(II) SHEEL REV: OATS TESLA EQUIPMENT, WITHOUT THE WRITTEN - PAGE NAME INVERTER: PERMISSION OF TESLA INC. ABB # PVI-3.6-OUTD-S=US-z-A THREE LINE DIAGRAM PV 6 9/6/2017 t Label'Location: Label Loca_ tion: ,- - • • • • • (C)(IC)(CB) . WARNING Fi r (DC)(CB) .RNING Per Code:' - ' , 1 Per Code: . ' • : Per Code: ; j i •. { ` •' t• ELECTRIC SHOCK • -■ , CEC 690.31.G.3 CEC 690.17.E THIS EQUIPMENT• BY CEC 705.12.D.2,c -•, ':� :. r, .• • • Label Location: • :• . RATING• SOURCES.MULTIPLE • •_ , (` r`,R.-' �., .' PHOTOVOLTAIC ••■ ■ - ■ (DC) (INV) DEVICES,'_: EXCLUDING MAIN . #;• i" IN THE •- POSITIONSUPPLY Per Code:• • -ENT ', r f« r �. ' , . CEC 690.13.6 . .. • ■ OF - '� Label Location: �.,, ,•.M. - , '' 4,' '; ", Label Location: a+. ,PHOTOVOLTAIC POINT OF (POI) '- - `• - �. t. MAXIMUM - • - INTERCONNECTION (DC) .(INV) `,�' ; ` Per,'Code: ` . Label Location: ; i �_ , ; . ; •t -• • Pei Code: .;~�; ' -. ,• • • CEC 690.54; CEC 690.17 (DC)(INV)(CB) ,, POWER MAXIMUM- - CEC 690.53 * ;` ` - TERMINALS• Per Code: • • SYSTEM ,, • ., :• . • . SIDEel ' .' k,' �` ELECTRIC - HAZARD . • . SHOCK CEC 690.35(Ft) , , �.. r t - VOLTAGEMAXIMUM ,' . • - a • POSITION. •- -• ' n.- r' .'.� aPHOTOVOLTAICTO • •is BE USED WHEN . • d 4' SHORT-CIRCUITCURRENT f+}•<�..v .,r .` w ■ :• -•■ ■ . INVERTER IS * ''w.�• tAND _•EAKER. MAY BE ENERGIZED •- w -•, UNGROUNDED - ,,*j, f r; ,' MAXIMUMAC A OPERATING CURRENT • MAXIMUM AC Label Location: i { . , OPERATING VOLTAGE.. _ * ti ' .f , , t :. . s. , ; w . • , t t,,..t �' � R . (INV) , Per. Code:ELECT _IC SHOCK HAZARD IF A GROUND FAULT IS INDICATED CEC 690.5(C) ,. • -GROUNDED ., i Label Location: UNGROUNDED CONDUCTORS. ENERGIZED PHOTOVOLTAIC SYSTEM ... (INV) ., E QQIRPED WITH -RAPID Per Code: ■ • CEC 690.56(C) " • `' "` " Label Location: ; • + " PHOTOVOLTAIC . POI ' , '+ • ,. () ( AC ) • - 4 .. ' ' . r` '. • Per Code: Label Location: CEC 690.13.6 CAUTION (POI) - DUAL POWER • Per Code: - i i SOURCE IS CEC 705.12.D.3PHVLTAIC a •SEC t . SYSTEM •Label Location: MAXIMUM AC • - (AC) (POI). ` A •' ... Per Code:MAXIMUNIAC CEC 690.54' t Label Location: OPERATING _ (POI)WARNING ' - • Per Code:'INVERTER CO CEC 705.12.D.2.b •-UT Labell (AC): AC Disconnect ocation: . (AC) ,4 . ,t _ - (C): Conduit , ` PV SYSTEM j ', (CB): Combiner BoxUTILITY ■ • FOR - _ r .. * .. S ' (D): Distribution Panel • , • • <,. � - .' ; W r '(DC): DC Disconnect V • (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect `(LC): Load Center • r . ,. •, _ (M): Utility Meter is - (POI):,Point of Interconnection • • ` •.• -- "- • • .Label Set .. _ , , ,. ', •• - - ' ," s ' . - . t. �� , • t Mounting Block Array Skirt y ; "Interlock .. ' Part No. 850-1633 Part No. 850.1608 or 500-0113 Part No. 8501388 or 8501613 f { ' Listed to UL 2703 Listed to UL 2703_ Listed to UL 2703 ,. Flashing Insert Grip Ground Zep V2 Part No. 850-1628 Part No. 8501606 or 8501421 Part No. 8501511 • + d' z c t Listed to UL 2703 Listed to UL 2703 Listed to UL 467 and UL 2703• �Qpo 14 PA P, Description " • it t r j v PV mounting solution for composition shingle roofs it ` ` A oW Works with all Zep Compatible Modules • " compp, - Auto bonding UL -listed hardware creates structural and electrical bond • - ` ' - ' ' • ZS Comp has a UL 1703 Class "A" Fire Rating when installed using modules from any manufacturer certified as "Type 1" or "Type 2" • Captured Washer Lag End Cap DC Wire Clip _ ,n U� LISTED - • Part No. 850-1631-001 Part No. Part No. 8501509 k` . Specifications 850-1631-002 (L) 850-1586 or 850-1460 Listed to UL 1565 , 1 850-1631-003„ '' (R) 850-1588 or 850-1467 'Designed for pitched roofs 850-1631-004 • Installs in portrait and landscape orientations ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 2703 1 - _ Wind tunnel report to ASCE 7-05 and 7-10 standards - .. - � , ' •• � " -' • t r ZS Comp grounding products are UL listed to UL 2703 and UL 467 • ZS Comp bonding products are UL listed to UL 2703" Engineered for spans up to 72" and cantilevers up to 24"' a • Zep wire management products listed to UL 1565 for wire positioning devices - Leveling Foot Part No. 850-1397 �• " ,,� • " t zepsolaccom - zepsolaccom Listed to UL 2703 s • " �'• , • This document does not create any express warranty by Zep Solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for This document does not create any express warrantyby Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for o• =k each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifyingthe suitability of Ze Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zs ats.com. responsible for ven m the suitability of Ze Solar's products far each use. Specifications are subject to change without notice. Patents and Apps: zs ats.com. _ " Po Y ZepSolar's 1 9 PP P P fY 9. ty ZepSolar's P 1 9 PP P -� Document # 800-1839-001 Rev D - - Date last exported: April 29, 2016 11:22 AM • Document # 800-1839-001 Rev D 1 - t Date last exported: April 29, 2016 11:22 AM \. T - • � - ' � ' - • + -'�_ - • ! � ' ` . - ;>• , ♦ t ~ ' •• •' .• • -. - - ,• ' _ ,♦ ,- - `t ". ,. � r` 'rte M • - � �Y ` Rapid Shutdown wiring diagram: 2 -RSD system Solar inverters ABB solar system accessories PV St ring 1 shutdown N - L � , Rapid Shutdown with Zep bracket for 600V • . • �.. wtmrrn Z . CC - • - *' Imo f s! = , 1 r ' '� •.i M v: ABBraptd• , 1 424VRWTn pyyp�n y. . shutdowns .� ""�xaena¢ . PV String tv tiFM T• i _ •7.r w. The inputs of both rapid shutdown boxes are'ratod for 25A which allows for sin gle,or paralleled string to be • ' connected to one input. Or%a 2 rooftop system either version of the Rapid Shutdown box, or both,'may be used. Technical data and types +- .; a Type code Single input Double input MPV source conductor input y • .� Max input current (per input) - 22.SAt /25 • Max in tit v.... a 600V .. P....................9..........:..'.............................................................. ............................................................................ ................-........................ .................... ............................ Number of PV source/out tit airs _ » ..1.. 4 Conductor_ size ' _ 1 - 'jPV output conductors output. •• . _� y f Number of PV out tit circuit pairs 1 2- t ............ .............. .......... ..... ..................... . ..................... .................. P • • s r r. ♦ Conductor size - y r - _ - --- i• - 148AWG ?� f fControl power ' Power consumption - <3.6W/24V/0.15A <7.2W/24V/0.3A . .......................................................................................................................................................................................................................... , Power.conductor size 18-16 AWG .n . ;........................................................... of RSD boxes allowed Per power supply 4 .. 2 ... . - - - IEnwronmental r%" r- ` 4 Mounting angle.................................................................i......... ..0-90' .............................................. s a Dimensions..�.x W.x..D...................................................................i............................ 7:.1"x6:7"x2.0^.... TBD.:. ABB now offers a low profile behind Two models are available to cover Highlights. . Weight............................................................................................... ' i 2.21b TBD....... the module rapid shutdown solution all system configurations; including - Meets NEC 690.12 while avoidin ................................................................... P Y 9 , 9 9 .` Operating temperature ran a -40°C to +75°C for.600V systems. This product a single input/output version and a the cost of additional conduit makingEnclosure raLng NEMA 4X ' 'provides a fail-safe solution for two-input/two-output version. this solution the most cost-effective Certifications uL ai:2o10 FCC Part 15 Ciass B {Warranty emergency responders to eliminate _ The unique features of each box rapid shutdown product available Standard warranty 5 nears ; ' voltage at the PV array in compliance can be used to maintain the specific - NEMA 4X enclosure provides added #Available models , R " " . _,Rapid shutdown kit RS1-1PN6-H4-Zkit RS2-2PN6-H4-kit with NEC 2014 Rapid Shutdown code configuration of the PV system. protection from the harshest rooftop Rapid shutdown (box onl) RS1-1PN6-H4-Z...................................... RS2-2PN6 H4............................................. ...... 1 .................................................... Y.................,......................................................................................................................................................................................... requirements. Dual outputs in the box maintain the conditions Rapid shutdown power supply kit . PSK1.3 benefits of ABB's dual MPPT inverter - The 25A rated inputs allow for information in this document is subject to change without notice The ABB Rapid Shutdown system • channels, while the single output box is paralleled strings to provide T "• + _ x • - i requires no extra conduit; minimizing perfect for small PV arrays utilizing one additional savings by reducing the ' - additional material cost and MPPT channel ors stems requiring two number of DC conductors to the Su + y q g Support and service For:more information please contact ©Copyright 2016 ABB. All rights associated labor. " rapid shutdown boxes. inverter; + ABB supports its customers with a your local ABB representative or visit: reserved. Specifications subject to, 4 Shutdown occurs at the rooftop box To further reduce system cost, the input -New low -profile, behind the module dedicated, global service organization - change without notice. t : when utility power is lost or when,the channels are rated up to 25A allowing design improves the look of the + , in more than 60 countries, with strong www.abb.com/solarinverters c ' PV system's AC disconnect switch is paralleled strings on one input. overall system by keeping wire regional and national technical partner 4 opened.management behind the array • '• networks providing a complete range of www.abb.com - r The Rapid Shutdown box can'mount t - ` life cycle services. • -t *�u directlyto the PV mounting rail or PVmodule and lay parallel to the roofingsurface. The NEMA 4X design permitsinstallation angles from 0-90' while r � t maintaining its water -tight seal from ,' r �' «r, mounted snow and driven rain. This device is shipped with the �t i4AL 11 ,! certification mark shown here i Power and productivity, 1,. ) t for a better for f+ H - - 2 ABB solar inverters I Product flyer for RSD with Zep bracket for 600V applications _ :� •t - r .• ` 1 � e' ` . . _ r - t' _. , * _ ,r, _ � .• * r • + rl - r�.t +yT - - •� a r + ^ • � .J Y' ti' a • '' !r •••. .• •• ya fe a4 i 4 .. Mono Multi Solutions " ! - 1 • 1 - Trina_ mount . L �' ,., �,. '' ... t T,. - y ,. ° _ - •'• r _ Y PRODUCTS POWER RANGE•. -w a .T 4 • ELECTRICAL DATA (STC) ' THE TSM-DD05A.1801) 1 280-305W rinamoun i• ° ( • t `. DIMENSIONS OF PV MODULE(mm/inches) r A wwra MODULE r MONOCRYSTALLINE MODULEr 4 ?. �` ^ C` 275'305W % y POWER OUTPUT RANGE a -FRAMED 60 -CELL MODULE•' Peak Power Watts-PAv,x (Wp)• ' - • mem. Name, l AL JA 9 '+' 0-•+5 .eau � • e • 31.4 wuwna w. 31.8 • cmw°u,y raN uar,n ra. � r -FRAMED 60 -CELL MODULE•' Peak Power Watts-PAv,x (Wp)• ' '275280 285 290 I 2� 9Y� 300 305• [=--output Tolerance -P- W)~ '+' 0-•+5 Maximum Power Voltage-VrwIV) tr 31.4 31.7 31.8 32.2 32.5 32.6 32.9 Maximum Power Current-Irasr(A) . 8.76 8.84 8.97 9.01 9.08 9.19 • 9.28 Open Circuit Voltage -Vac M 38.7 39.0 39.3 39.5 39.7 39.9 40.2 rcuit Current-I% .26 .35 - -- 45 7.48 *51 8.3 7.677.7_ ryl(%)A) Module Efficiency 16.8 • 197.1 197.4' 17.7 986 18.0 STC Irradiance 100064/ma, Cell Temperature WC Air Mass AM1.S. • •Measuring tolerance: ±391 ELECTRICAL DATA (NOCT) t - F• 205 209 r + 216 to 223 227 Maximum Power Voltage -Vs -M 29.2 29.4 29.6 29.9 30.2 ` 30.4 30.6 - Maximum Power Current-Irew(A) 7.02- Maximum Power-Pswi(Wp) 205 209 r + 216 to Maximum Power-Pswi(Wp) 205 209 212 216 220 223 227 Maximum Power Voltage -Vs -M 29.2 29.4 29.6 29.9 30.2 ` 30.4 30.6 - Maximum Power Current-Irew(A) 7.02- I 7.10 7.17 7.23 7.28 7.35 .7.42 Open Circuit Voltage-Voc M „ 36.0 36.3 36.6 ,' 36.7'. 36.9 37.1 37.3 Short Circuit Current -Ix (A) 7.48 7.55 • �. 7.63 7.677.7_ 1 _ 7.78 7.84 NOCE Irradiance at 800W/m•, Ambient Temperature 204, WInd Speed lm/s. Maximize limited space with top -end efficiency ®• 40/1.57 - 992/39.1 • �Q • Up to 186 W/m2 t ' MECHANICAL DATA 6% power density ' 8.Low thermal coefficients for greater energy production at high • Backwew • MAXIMUM EFFICIENCY— - ' operating temperatures ...... ,........,...PA . ..,. ,.., . Highly reliable due to stringent' quality control , t + 't X043' Solar Cells Monocrysialline 156.75 x 156.75 mm (6 inches) Cell Orientation '! 60cells(6x 10) - _- Module Dimensions 1650 x 992 x 40 mm (65.0 x 39.1 x 157 Inches) _ Weight 19.6 kg (43.1 Ib) • ' A.. 0-+5W . ® , Over 30 in-house tests (UV, TC, HF, and many more) * Glass 3.2 mm (0.13 inches), High Transmission, AR Coated Tempered Glass • l `. POSITIVE POWER TOLERANCE e In-house testing goes well beyond certification requirements , r PID resistant 100% EL double inspection - J -B.;- - • ' Founded in 1997, Trina Solar is the world's leading - -LI e Fire Type �_.r.., _UL 1703 Type 2, for Solar City ' .. comprehensive solutions provider for solar energy. we - - .� believe close cooperation with our partners is critical to Trina Solar distributes its PV y. Certified to withstand the most challenging 35/138 • ,�, • success. now products F to over 60 countries all over the world. Trina is able to environmental conditions .^ (A -A) -1 provide exceptional service to each customer in each - • I-V CURVES OF PV MODULE(305W) - ' c r market and supplement our innovative, reliable • 2400 Pa wind load _ i� products with the backing of Trina as a strong, • 5400 Pa snow load . s1A r ^ Backsheet' White Frame Black Anodized Aluminium IAlloy J -B.;- IP 65 or IP 67 rated - Cables - - Photovoltaic Technology Cable 4.Omm2(0.006 inches), 1 1000 mm (39.4 inches) Connector MC4 . • - ,' Fire Type �_.r.., _UL 1703 Type 2, for Solar City 2 - bankable partner. We are committed to building '• en : strategic, mutually beneficial collaboration with ' • 35 mm hail stones at 97 km/h installers, developers, distributors and other partners. • ' g as so •' _ * 4.0a + a'0 TEMPERATURE RATINGS ' MAXIMUM RATINGS •. - , 1� �� 2A _2mwrm• Comprehensive Products - And System Certificates • re vatngeM IEC61215/IEC61730/UL1703/IEC61701/IEC62716 - 1 • , T, 1509001: Quality Management System .t 1 ;�. - rP-V CURVES OF PV MODULE(305W) 150 14001: Environmental Management System . • a a aso r • 15014064: Greenhouse gases Emissions Verification - ' toowvrm• ao° - NOCT1Nwmrul Operadng CNl Temperature) 44°C (12°Q Temperature Coefficient o(Pseil --03996/°C ' Temperature Coefficient of Voc -029,Jvc: Temperature Coefficient of Isc 0.05%PC ' Operational Temperature -40-+85°C Maximum System Voltage t000V OC (IEC) ' t000V DC UL) Max Series Fuse Rating 15A " ' r ' OHSAS 18001: Occupation Health and Safety -"•; ' °,. i • _awAYm_ _ - NOT Cam6ineraaawitlstw°a, more , e - ' Management System - - LINEAR PERFORMANCE WARRANTY - - ` - € ,�, -foo parallel connection) . •a ` -1 amus /'�41 ' c 10 Year Product Warranty 25 Year Linear Power Warranty - r - , _ i� WARRANTY - PACKAGING CONFIGURATION _ •ooe' ' ^ - tam 97% ' •Addidonalvalue r , f _ _ 50 - - _ -,..._ .. _10 year Product Workmanship Warranty { Modules per box: 30 pieces ♦ •! ^�,i ® �a vp��✓ 'i"• rce ❑ bom Trina,Solarslinear warran ; eo% • °• 1. vmugeM -+0 50 + 25 yearLinear Power Warranty Modules per40'contalner. 840 pieces ry T' ` (please refer to product warranty for details) , r - - V • Years s t0 is 20 25 r • ' CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Trina'solar ■ Trina Linear Warranty Standard Ste Warranty f ty • ° Pry' • Trinas'olar . , ' 0 2017 Trina Solar Limited. All rights reserved. Specifications Included In this datasheet are subject to change without notice. , _ Version number: TSM EN 2017 A p - www,trinasolar.com • - This family ofsingle-phase string Solar inverters ABB string inverters ' factor ' in�e�erocomp|amemu�ho�yp�a `Grid �mepmwer1rau�ngandimprnxed — Sing|o'phaooan�thmo'p�auooutpu� � ' `Power ' wiri��6­f6'��i'�a' t'i'o' n , Terminal block, Pressure clamp, AWG20-AWG6 number ofrooftop solar panels ' energy harvesting. . . _ grid connection . '�.IlInput protection devices' ' enabling homeowners toget the most 4 —'Wide input'voKago'omgofor -Varistor, p��!�rity protection Yes efficient energy harvesting for the size efficiency atall output levels allowing .' increased stringing flexibility and ' . .j3py�� ^ PV array ground Lault detection - This family ofsingle-phase string � Highlights x ' factor ' in�e�erocomp|amemu�ho�yp�a `Grid �mepmwer1rau�ngandimprnxed — Sing|o'phaooan�thmo'p�auooutpu� � ' `Power ' wiri��6­f6'��i'�a' t'i'o' n , Terminal block, Pressure clamp, AWG20-AWG6 number ofrooftop solar panels ' energy harvesting. . . _ grid connection . '�.IlInput protection devices' ' enabling homeowners toget the most 4 —'Wide input'voKago'omgofor -Varistor, p��!�rity protection Yes efficient energy harvesting for the size efficiency atall output levels allowing .' increased stringing flexibility and ' . .j3py�� ^ PV array ground Lault detection 2 for each channel Pre start-up and uires floating arrays) ' ufthe property. aconsistent and stable performance energy harvesting . ` Additional highlights '� The high-speed and pmoiooMPPT ' ' ` . This inverter offers odual input �. ' *u�mn algorithm offers real-time power .` . section that processes two strings � ���di����y ` ^ ' � - ' (for connection »nlaptop o,data . with independent Multiple Power Point highest efficiency of -up ko97Dpercent. harvesting � ' . ^ �Qgo� T�v�oi���K�o��m�� , '� O��N�A4X��e����CEC ' .^ This is especially useful �rooftop ' the invo�orouK�low-power �unrestricted httime consumption '. . inu�aUouionuwith�,oU��mn� in�o||cuionow�hmdvoo�ouhngoizo� AvqiIpmp,with the optional VSN30O ' . . ohontotionahnmtwo oub'anayo ' This mggad.outdoor inve�o,has �mtogn�odDCdiaoonnomu~�nh' ' ' .^ xooand . VVifiLogg�Co��y� ^ ohon�din��omn directions, or boondou�nod�obeaoomp|e�� ' . � ~ ^ ' affordable wireless � Standards ('SVersion) 'Revenue grade meterANSI . and VVooV.' Compliant with NEC 08O12when ' lEnvironmental^ � -model-s) � ' . , . -used with A88'oRap�Shutdown ' ' .'The �. . ' device. � . ' . ^ . - harvestingopdn]�ono�ycondition. ^ �omouaoandu�wdhDCAmFauk < ^ , ` ^ �, Circuit |nmnuptoxy\FCV»ocomply w�hNEO88O11 � ' Capability enabled _ nominal —____, and with _ power ^ . ^' ., � ` uABB solar inverters | Product flyer x" � ~ . ' —/walab|owithopionalmvenue ` 'Ilk gmdomo�,ANG O12�2O.(�5% accuracy class FM vorsion An ' ` . ` ~ ~ �' . ' ^� � ' Technical data ' ' ^ " — 7'~^ . _ . ,~ fGeneral specifications. `4666i xxuu3800w . ' 4200W ~ � Maximum 3000 3300' 3600 1 j560 42'00'i''F42001 1,4200 46001 46001 .—. . . Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V ' JInput side (DC) T ` . ' ^ . '___ ^ ' . full power MPPT : ��nq 160 -530V 120 -530V I 140-530V 140- 30V ° . ~a=."""current """"°" ="°" M,,. in 20A 32A 32A 32A �ammumoxo�o�"x anu 12.5A 20.OA OA OA �. . . . Terminal block, pressure clamp, AWG20-AWG6 . - This family ofsingle-phase string The high-speed YmPPToffers n»a|' Highlights x ' factor ' in�e�erocomp|amemu�ho�yp�a `Grid �mepmwer1rau�ngandimprnxed — Sing|o'phaooan�thmo'p�auooutpu� � ' `Power ' wiri��6­f6'��i'�a' t'i'o' n , Terminal block, Pressure clamp, AWG20-AWG6 number ofrooftop solar panels ' energy harvesting. . . _ grid connection . '�.IlInput protection devices' ' enabling homeowners toget the most The flat efficiency curve ensures high- —'Wide input'voKago'omgofor -Varistor, p��!�rity protection Yes efficient energy harvesting for the size efficiency atall output levels allowing .' increased stringing flexibility and ' . .j3py�� ^ PV array ground Lault detection 2 for each channel Pre start-up and uires floating arrays) ' ufthe property. aconsistent and stable performance energy harvesting . ` across the onUminput voltage and '� The high-speed and pmoiooMPPT ' ' ` . This inverter offers odual input �. output power range. algorithm offers real-time power .` . . ^ ` Maximum AC OCPD rating section that processes two strings � The transformer|ess _�___�"----_ ���di����y ` '' . with independent Multiple Power Point highest efficiency of -up ko97Dpercent. harvesting � ' . ^ ������. � T�v�oi���K�o��m�� , '� O��N�A4X��e����CEC ' .^ This is especially useful �rooftop ' the invo�orouK�low-power �unrestricted httime consumption '. . inu�aUouionuwith�,oU��mn� in�o||cuionow�hmdvoo�ouhngoizo� onvimnmon��oondi�iono � � ' . . ohontotionahnmtwo oub'anayo ' This mggad.outdoor inve�o,has �mtogn�odDCdiaoonnomu~�nh' ' ' lCommunication ^ ohon�din��omn directions, or boondou�nod�obeaoomp|e�� �comp|iunnowhh��rnationa| ' . � ' unbalanced strings (for example: East sealed unit. »owithstand the harshest Standards ('SVersion) 'Revenue grade meterANSI C1 2.20, 0.5% accuracy class (-M_ and VVooV.' environmental conditions. ' lEnvironmental^ � -model-s) du�'in��aoo�onowhh ` ' .'The ' indopondor��4PPTonub�amom � . ' . ^ . - harvestingopdn]�ono�ycondition. ^ �Acoustic noise emission level < ^ , ` ^ �, ��--�&�NN��K�v � ' Capability enabled _ nominal —____, and with _ power . ^' ., � ` uABB solar inverters | Product flyer x" • - � I � •f . �... _. • - � f t', L . •�• 'tr � � '- � ,•. � y�, `� - ," • ,,� ",• f • -•1, , - a 1. _ ,f' p ' L � R•, �•w _, -� Block diagram of PVl-3.0/3.6/3.8/4.2-TL-OUTD t` ; r r '. . {` _ :, . a -------------- ------------- ________,_______________-___________-_____________________________________ 4. For more information please contact ©Copyright 2017.ABB. All rights MRRTI INVERTER service with,a your local ABB representative or visit: • ' reserved. Specifications subject to µ Support and servic .(DUDO BULxCARS (DUAQ LINE GRID PARALLEL ABB supports its cus • IN1.2(+)' + + + +fo' + + ..I1IrI FILIER "� ' L x . ., --dedicated, global service'_organization _ - « '^ - ' change without notice.. INI INI - FINI INI I i INI INIILS _ ., g + - :' ' e -.',v .;w� , in more than 60 countries; with strop WWWabb.com/solarinverters 'INLI(-; • - - - �l,'� _ _ -�2 a partner - y' regional and national technical p e DC' - l____, networks providing.a complete range of WWWabb.com + - ti + o i i . �N N • ' ". AFD( ------------- I - - ---*- J T - .g r, M," life cycle services.. CO . ~( .IN2 —{I <• .t •. RESIDUAL CU EW ..i' '1 d f .. ❑ 1 ! .y ,'� W2 IN2 ' IN2 IN2 y 'IN2' 1-�-• • )- DETECTION 1�y, �'1� i '. _ • '. , ' _. . U, .. . IN2.(1. -4 a>✓ 2 •• ♦• RSCes ' _ T _ w ••` • - iii - L TIR W2.20 N Cc ____ ___ _ ___._ ___'___ - __a • , REN •t• .. _ TUVRheintend N 'Do ' WIRING BOX _ _ - - _ _ - _ V ° , • 'L -'is + '? 0.7 'REMOTE CONiROI•' f • , C^F•' V---- ---- +R. rr �•G T a , . • , � '1 : I • h • _ • ' , � • - -� •„ DEnCT10N . ALARM -` /. + - �••. .� , Y • _ _ + c N A t1 1 ; :This inverter is marked with one of theNo y CONLROLCIRCUn C -+t two certification marks'shown here (TuV•; - L - ' *• or CSA).' _ • • r �. • ' Remote control function not available on -A version ` - �� � ` � �► • + , � • - 1 - .� x.r t f J1% III Ip OWN Type code , PVI-3.0-OUTD-US PVI-3.6-OUTD-US' PVI-3.8-OUTD-US PVI-4.2-OUTD-US mom= MM _ Enclosure rating ... �mmmm ®MM®M ` Coohn 9 M x.r t f J1% III Ip Technical data and types Type code , PVI-3.0-OUTD-US PVI-3.6-OUTD-US' PVI-3.8-OUTD-US PVI-4.2-OUTD-US - -- , (Mechanical specifications _ Enclosure rating ... : NEMA 4X ` Coohn 9 ............................................................................:.................:...................................................... Natural convection r ' ........................... ....................... Dimensions H x W x D .................. .............................................................. . ............................ ........ .. ...... �2..._.... ...................................... 33.8 x-12.8 x 8.7in (859 x 325 x 222mm ......... ........... ._.............................................._..................... . .............................................. •Weight <47.31b (21.:3kg! '.. . , ...............................................................................................:.............................I................ Shi In wei ht ...PP....g...........................................-...................................................................:.................................................._.................................................5_............g),....... ...:........................... 2 _ ................................................... r < 601b 27.0 r. - ` ' Mountin s stem - 9:...X Wall bracket' ............................................................................................................................ ..,.................... ............. ... _ Bottom: (2) pre -drilled opening for s/ Inch conduits and concentric markings for 1 inch ' (both sides) and 11/2 inch conduit (DC side only) « - _ Conduit connections2 Sides: (2) pre drilled opening for s/a inch conduits with concentric markings for 1 inch " ' (both sides) and 11/2 inch conduit (DC side only) i i... ! ` •. Back (2) concentric, markings• for.3/.inch and 1, inch conduits L` ` ............................ DC switch rating (per contact) (ANj 25/600 " ' ISafety and Compliance +t ' • " level (floating arraY)CSA. f... ...Isolation ... ............ .................. .......:.............. .................... ..... ........UL.... a1.....tn.s.........1......... YranAsformerless ....... •. N 1 7 1 ........... 17 wl uppemen EEE1547 IEEE1547 1, C22.2 0 - Safety and EVC standard .. �: :....UL1998 UL.1699B, .............................................. Part lssB.....:........ Safet a roval Y.... pp........................................................................................................................................................ . CSAaoUVw s 1 Regional Compliance Tested to UL 1741 SA,.Rule 21,.HECO, r, NEC 2014 690.11, NEC 2014 690.11.12 with ABB rapid shutdown device - r (Available models _ _ With DC switch, wiring box, arc fault detector and interrupter PVI-3.0-OUTD-S- PVI-3.6-OUTD-S- PVI-3.8-OUTD-S- : ,PVI-4.2-OUTD-S- US -A US -A US -A•• US-A :.........................................................................r....n........:...................................... With DC switch, wiring box, arc fault detecto a d - ....................... vi .........................._............................................................4.............................' PVI -3.b f5U7D S 3 6 CSUYD-S PVI -3.8 Z7UTD-S PV1.4.2-UUTD S interrupter and..revenue..grade.meter................................:....... ................. US -M -A US M -A US M A US -M -A ............................................................................................... .. ........ _ ............... .... ................... 4, Rapid shut down power supply Yes • Yes Yes Yes ' • • 2. When equipped with optional DC switch and wiring box. ' } All data is subject to change without notice ,• . - ' - '+• - ` c Product flyer for PVI -3.0/3.6/3.8/4.2, TL-OUTD-I ABB solar inverters 3' s x.r t f J1% III Ip BUTTE COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds Permit No: B17-2820 Issued: 11/28/2017 APN: 009-132-001 Address: 1767 SPRUCE ST, GRIDLEY Owner: MARSHALL, JAMES R. & NAYELI E. Permit Type: SOLAR ROOF -RES Description: SOLAR ROOF - RES (6.54KW) Flood Zone: SRA Area: SETBACKS for Zonong- AG_ SRA. PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings III Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed ShearwalUB.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkle Test or Final 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin /Unde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: F naI Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINAL 74 F I it. •, -rroject anal is a uernncate of occupancy for (ttesiaennai vniy) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A I YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION j - BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 124 HOUR INSPECTION (IVR)#:530.538.4365 OFFICE #: 530.538.7601 FAX#:530.538.7785 www.ButteCouniy.net/dds j Site Address: 1767 SPRUCE ST Owner: Permit NO: B 17-2820 APN: 009-132-001 j MARSHALL, JAMES R. & NAY Permit type: MISCELLANEOUS 1767 SPRUCE ST. Issued Date: 11/28/2017 By JMD Subtype: SOLAR ROOF -RES GRIDLEY, CA 95948 Expiration Date: 11/28/2018 Description: SOLAR ROOF - RES (6.54KW) 5304057519 Occupancy: Zoning: Contractor Applicant: Square Footage: HOOKED ON SOLAR INC I HOOKED ON SOLAR INC Building Garage Remdl/Addn 4035 GRASS VALLEY HIGHWAY' 4035 GRASS VALLEY 0 0 0 AUBURN, CA 95602 AUBURN, CA 95602 Other Porch/Patio Total 5303203949 5303203949 0 0 0 Contractor (Name) State Contractor's License No. / Class / Expires HOOKED ON SOLAR 949707 / B / 6/30/2019 I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I amlicensed under provisions of Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license in full force and effect. X Contractor's Signature Date I I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: aI have and will maintain a certificate of consent to self -insure for workers' compensation, issued by the Director of Industrial Relations as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. Policy No. I ❑I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance varier and policy number are: Carrier: STATE Policy Numb@QSg7j 5 Exp. 41W 0. 2018 I certify that, in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that. if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Signature i Date WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST, AND ATTORNEY'S FEES. I I hereby affirm under penalty of perjury that there is a construction lending agency for the performance of the work for which this permit is issued (Section 3097, Civil Code). Lender's Name and Address Lender's Name & Address City) State Zip 1 hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' State License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): ❑I, as owner of the property, or my employees with wages as their sole compensation, will do U all of or U portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State License Law.). I am exempt from licensure under the Contractors' Slate License Law for the following reason: Owner's 'By my signature below, I certify to each of the following: I am L) a California licensed contractor or U the property owner' or U authorized to act on the property owner's behalf *. I have read this construction permit application and the information I have provided is correct. I agree to comply with all applicable city and county ordinances and state laws relating to building construction. I authorize representatives of this city or county to enter the above -identified property for inspection purposes. California Licensed Contractor, Property Owner.' or Authorized Agent 'requires separate verification form "requires separate authorization form Total Fees: $511.00 • Fees Paid: $511.00 Balance Due: (None) Job Value: $20,000.00 i i I SHEET INDEX GENERAL NOTES: `~ PV-1.0COVER &NOTES PAGE'_t.•�.� 1. PV -2.0} SITE PLAN: PV -3.0 ANCHOR & DETAILS F• ° " �-- r ., r i PV -4.0 ELECTRICAL DIAGRAM & CALCS • 4`.. `�` 2' PV -5.0 ACPV MODULE -INVERTER SPEC w PV -6.0 RACKING METHOD '' ; ���F"F *; { 3. PV -7.0 MOUNTING AND FLASHING > -�'' PV -8.0 GROUNDING METHOD �'�� ' j }• `® - i� ''# ,PV -9.0 SAFETY LABELS G' . , rF ,' +I R,I,1 6 4. PV -10.0 MICRO INVERTER MAP 'FIELD SE} Q ® _ �� 4 ' . i ;, a .i • `'7. ° k ;.>� LEGEND -- 5. PROPOSED EXISTING�? + o ! i - ELECTRICAL - EQUIPMENT s ' ��// 3' o - -F 6. - VENTS 7. •-._' } ,�. . �._T tom. APPLICABLE CODES: ; • _ ; 4 <_ -,,,, `- • 2016 CALIFORNIA BUILDING STANDARDS (CBC) �'°* _ • > ; ate_ ��F Fs • 2016 RESIDENTIAL BUILDING CODE (CRC) • 2016 CALIFORNIA ELECTRICAL CODE (CEC), • ;ice • 2016 CALIFORNIA FIRE CODE (CFC). " •• '•- PREFERENCE SEC. 605.11.1. • + - •' - _' 2034 MARSHALL J ,'` ' •• SMOKE DETECTORS AND CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH CRC R314 AND CRC R315. - `� • . j 8. �a '<' `�' FIRE ACCESS NOTES: 9' 3 1. ALL SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE WITH 'Oak Sf._._... �'..�---.T'-- -- UL217 AND INSTALLED IN'ACCORDANCE WITH THE PROVISIONS nr OF THIS CODE AND THE HOUSEHOLD FIRE WARNING ' + EQUIPMENT PROVISIONS OF NFPA 72. SYSTEMS AND - • COMPONENTS SHALL BE CALIFORNIA STATE FIRE MARSHAL A DC DISCONNECTING MEANS SHALL BE INSTALLED AT A , READILY ACCESSIBLE LOCATION EITHER OUTSIDE OF THE BUILDING OR STRUCTURE OR INSIDE NEAREST POINT OF ENTRANCE OF THE SYSTEM CONDUCTORS AS PER SECTION 690.14 OF THE CEC. HEIGHT OF THE INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE 'PROVIDED. PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR' SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 6.54 kW (DC) MODULES: , (20) SPR -E20 -327 -C -AC CIRCUITS: _ CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES = 10 TILT: 30° AZIMUTH: 182` 272' INSTALL TYPE: COMP INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL SP LEASE # 1176577 LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE SIGNED BY: EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. ' PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED , NON-COMBUSTIBLE. - PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. THE SMOKE ALARMS SHALL BE INSTALLED OR VERIFY TO ENSURE THE SMOKE ALARMS ALREADY EXISTING WHEN ALTERATION OR REPAIR TO GROUP R-3 OCCUPANCY EXCEEDS $1,000 CRC R314.6. AND IN ANCE WITH CA CODE OF lI UN .P O W E R� ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE CARBON MONOXIDE NOTES:. WARRANTED. 1. CARBON MONOXIDE ALARMS ARE REQUIRED AT THE THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE, . by Hooked on Solar , WITH ARTICLE 690 OF THE 2016 CEC AND 2016 CRC. 1.1. ON THE CEILING OR WALLS OUTSIDE OF EACH SEPARATE? PER CEC 705.12(d)(7), LOCATION OF BACK FED BREAKER SHALL SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS SSESORS PARCEL#: BE INSTALLED FARTHEST/ OPPOSITE END FROM THE MAIN 000-000-000 OVER -CURRENT DEVICE OR MLO. PARCEL ACRES: O.00AC WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS SIGNS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS 3. SOLAR PANELS SHALL BE NO HIGHER THAN 3 FEET BELOW THE "CAUTION: SOLAR CIRCUIT" EVERY 1OFT.. ' RIDGE IN ORDER TO ALLOW FOR FIRE DEPARTMENT SMOKE A DC DISCONNECTING MEANS SHALL BE INSTALLED AT A , READILY ACCESSIBLE LOCATION EITHER OUTSIDE OF THE BUILDING OR STRUCTURE OR INSIDE NEAREST POINT OF ENTRANCE OF THE SYSTEM CONDUCTORS AS PER SECTION 690.14 OF THE CEC. HEIGHT OF THE INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE 'PROVIDED. PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR' SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 6.54 kW (DC) MODULES: , (20) SPR -E20 -327 -C -AC CIRCUITS: _ CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES = 10 TILT: 30° AZIMUTH: 182` 272' INSTALL TYPE: COMP INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL SP LEASE # 1176577 LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE SIGNED BY: EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. ' PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED , NON-COMBUSTIBLE. - PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. THE SMOKE ALARMS SHALL BE INSTALLED OR VERIFY TO ENSURE THE SMOKE ALARMS ALREADY EXISTING WHEN ALTERATION OR REPAIR TO GROUP R-3 OCCUPANCY EXCEEDS $1,000 CRC R314.6. AND IN ANCE WITH CA CODE OF CHECKED BY: JAA REGULATIONS,' O SITEAPPROVED, D V DIVISION FOR PURPOSE FOR WHICH CARBON MONOXIDE NOTES:. THEY ARE INSTALLED. 1. CARBON MONOXIDE ALARMS ARE REQUIRED AT THE 2. ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO FOLLOWING LOCATIONS: NOT REQUIRE.THE PLACEMENT OF GROUND LADDERS OVER 1.1. ON THE CEILING OR WALLS OUTSIDE OF EACH SEPARATE? OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS 1.2. ON EACH STORY WITHIN A DWELLING UNIT, INCLUDING WHERE THE ACCESS POINT DOES NOT CONFLICT WITH BASEMENTS. OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR 1.3. •THE CARBON MONOXIDE ALARMS SHALL BE LISTED AS ' SIGNS COMPLYING WITH THE REQUIREMENTS OF UL 2034: CARBON 3. SOLAR PANELS SHALL BE NO HIGHER THAN 3 FEET BELOW THE MONOXIDE DETECTORS SHALL BE INSTALLED IN ' RIDGE IN ORDER TO ALLOW FOR FIRE DEPARTMENT SMOKE ACCORDANCE WITH THIS CODE, THE CURRENT EDITION OF VENTILATION OPERATIONS NFPA 720 "STANDARD FOR THE INSTALLATION OF CARBON N f MONOXIDE (CO) DETECTION AND WARNING EQUIPMENT" PROJECT SITE AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS NTS PER 2016 CRC SECTION R315.3. 11 . DRAWN BY: AGN CHECKED BY: JAA DESCRIPTION DATE REV CUSTOMER NAME: JAMES MARSHALL 1767 SPRUCE STREET GRIDLEY, CA 95948 530-405-7519 nayelig2222@gmail.com SHEET TITLE: COVER/ SITE PLAN PROJECT #: 2034 MARSHALL, J SHEET #: 1.0 DATE:' 8/31/17. 1:10 r SUNPOWER� by Hooked on Solar SSESORS PARCEL #: 000-000-000 PARCEL ACRES. r s 0.00AC i (! SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 6.54 kW (DC) MODULES: (20) SPR -E20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES = 10 TILT: 30° AZIMUTH: 182' 272' INSTALL TYPE: COMP I SP LEASE # 1176577 f . . J SIGNED BY: DRAWN BY: ' AGN CHECKED BY: JAA DESCRIPTION DATE REV CUSTOMER NAME: JAMES MARSHALL 1767 SPRUCE STREET GRIDLEY, CA 95948 530-405-7519 nayelig2222@gmail.com SHEET TITLE: •SITE PLAN PROJECT #: 2034 MARSHALL, J SHEET #: 2.0 DATE: 8/31/17 1:10 r i 2 L -FOOT RAIL � I I MODULE • (E) 2x4(TRUSS/RAFTER)' ANCHOR WITH FLASHING ROOF AND MODULE PROFILE SUNPOWER� 1.25 by Hooked on Solar - � .' DECK SSESORS PARCEL #: 000-000-000 . I I I PARCEL ACRES: '2x6 RAFTER—,, I I 3.00 O.00AC " • I j _ ` 1" — ALLOWED LAG INSTALLATION ZONE ANCHOR DETAIL" I'3' MIN fIRE SETBACK O _, • I 1 1 r`l/ I 1 I I I I I I I I • I I I I I I I �j j 1 1 1 I I I• I 1 I I I I I I I 1 1 I I 1 I I I• 1 1 1 I I I I I I I I I (E) TRUSS LAYOUT I 24" O.C. 1I 1 I 1 I 1 RAIL CHOR, I I _ T 1 I 1 I I I -T" I I I I I 1 T-1 I 1 I I 1 I 7 I I I I I I I I I I I � -I- I � 1 I 1 1 I I I I I . I I I I I I' I 1 1 I ( 1 1 1 I I I 1 I I ' 1 I I 1 I I' I I - 1 1 I I 6' I AN OR 1 I .�- I 1 I 1 1 I 1 I I I I I I 1 1 ORIZQNTAL �ACIN I!- 1 I •1 I I I I I I I I I I I I I 11 1 1 1 1 1 I I I I .I ! I I I I I I I I I � l l i I I I 1 1 1 1 1 1 1 I 1 I 1 1 1 I 1 1 I I I I 1 1 1 NOTES: 1. RAILS TO BE 211 MIN -14" MAX FROM EDGE OF PANEL WHEN IN LANDSCAPE ORIENTATION. 2. RAILS TO BE 2" MIN - 16" MAX FROM EDGE OF PANEL WHEN IN PORTRAIT ORIENTATION. I. SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: - 6.54 kW (DC) MODULES: (20) SPR -E20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES = 10 TILT: 30° AZIMUTH: 182° 272° INSTALL TYPE: • I COMP SP LEASE # 1176577 SIGNED BY: DRAWN BY: AGN CHECKED BY: • JAA DESCRIPTION DATE REV CUSTOMER NAME: JAMES MARSHALL 1767 SPRUCE STREET GRIDLEY, CA 95948 530-405-7519 nayelig2222@gmail.com SHEET TITLE: COVER/ SITE PLAN PROJECT M 2034 MARSHALL, J SHEET M -3.0 DATE: 8/31/17 NTS . r 'e EXISTING: MAIN;SERVICE PANEL RATINGS. , ,MFG/MODEL SQUARE D DISCONNECT AMP BUS AMP RATING 100 A SERVICE VOLTAGE, 240 V MAIN OCPD RATING 100 A TOTAL'SYSTEM RATING 40 A TOTAL INVERTER RATING 40 A AC SUB PANEL - RATINGS' BUS AMP RATING 125 A SERVICE VOLTAGE 240 V MAIN OCPD RATING 40 A INVERTER OCPD RATING AS SHOWN ^ ]-BOX 4, , L DISCONNECT AMP NEMA 3R MINIMUM I'N'STALLER STALLER NOTE: AC SUB PANEL - RATINGS' BUS AMP RATING 125 A SERVICE VOLTAGE 240 V MAIN OCPD RATING 40 A INVERTER OCPD RATING AS SHOWN ^ ]-BOX 4, , USE 40A FUSE DISCONNECT AMP NEMA 3R MINIMUM I'N'STALLER STALLER NOTE: ; .' SU N P O W E R� REQUIRED WITH INVERTER OUTPUT CIRCUIT CONDUCTORS ARE 4 WATERPROOF SPLICES POLARITY SENSITIVE. (P) RAID"(TYP) HOOlted OR OTHER APPROVED TERMINATION HOOKED ON SOLAR SHALL BE OBLIGATED TO MATCH PROJECT #: 2034 MARSHALL, J by on.Solar.' METHOD. ° CONDUCTORS FROM TRANSITION CABLE TO SUPPLIED v M / USING UL LISTED ACPV OUTPUT CONDUCTORS. RECEPTACLE PROTECTIVE CAP ]-BOX ? r ` ItON THE LAST MODULE •.{,. LUGS'Y- ASSESORS PARCEL #: 000-000-000' .. _ CABLE OF THE BRANCH CIRCUIT . PARCEL ACRES: . A r O.00AC 871 I1. DC A DC e AZ DC .a ° AC'DISCONNECT DG222NRB USE 40A FUSE DISCONNECT AMP 60 `• A RATING DISCONNECT VOLT 240, V RATING a q^ MAX OF 12 MODULES IN A 3 CIRCUIT #1 , BRANCH CIRCUIT - THIS + + CIRCUIT HAS 10 MODULES. ACPV ' " ` CHECKED BY: JAA 3 SUPERVISOR REV MODULE#1 MODULE #2 MODULE #10 CUSTOMER NAME: JAMES MARSHALL 1767 SPRUCE STREET ' GRIDLEY, CA 9.5948 530-405-7519 nayelig2222@gmail.com •,; T LINE SIDE TAP PROJECT #: 2034 MARSHALL, J SHEET M 4.0 DATE: 8/31/17 M / USING UL LISTED •.{,. LUGS'Y- _ f��/ - 20 A . FCV1 A DCA A DC _ A DC y SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 8:54 kW (DC)- MODULES:4 ` (20) SPR -E20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES = 10 TILT: - 30° ' AZIMUTH:. 182° 272° INSTALL TYPE: yt COMP AC DISCONNECT `- MAX OF 12 MODULES IN A ' ' " . _ SP LEASE $� 1176577 �.' 20`A' ` CIRCUIT #2 x BRANCH CIRCUIT - THIS CIRCUIT HAS 10 MODULES. 20 +.MAIN o t. r° + •SIGNED BY: �` _ v SUB MODULE #1. MODULE #2 a MODULE #10 INSULATED EGC SEE NOTE 3 FOR INVERTER i. 8'AWG, GREEN ' .: CONDUIT TYPE: ROMEX ' CONDUIT SIZE: 12/3 CONDUCTOR TYPE: THWN-2 - . F r r CONDUCTOR SIZE: 12 AWG k ; NUMBER OF CONDUCTORS: (2 RED, 2 BLACK, 2 GRND) - SEE NOTE 4 FOR INVERTER SEE NOTE 4 FOR INVERTER CONDUIT TYPE: EMT w CONDUIT TYPE: EMT CONDUIT SIZE: 3/4" CONDUIT SIZE: 3/4" ' CONDUCTOR TYPE: THWN-2 CONDUCTOR TYPE: THWN-2 w - - CONDUCTOR SIZE:"8 AWG CONDUCTOR SIZE: 12 AWG • NUMBER OF CONDUCTORS: NUMBER OF CONDUCTORS: (1 RED, 1 WHITE, 1 BILK, 1 GREEN) ,(1 RED, 1 WHITE, 1 BLK,'1 GREEN) " ' EGC SIZE 8 AWG (NEC 250.122) EGC SIZE 8 AWG (NEC 250.122) NOTES FOR INVERTER CIRCUITS ,. c •+ 1) IF UTILITY REQUIRES AVISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET';-. THE REQUIREMENT? YES X NO N/A "•' — .' ` ' 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE Y r ` REQUIREMENT? YES NO N/A - X - 3) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO _ , - ,� INVERTER OCPD AMPERE RATING. l� 4) TOTAL OF 1 INVERTER OCPD(S) ONE FOR EACH INVERTER, DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%'BUSBAR EXCEPTION IN • 690.64(B)(2)(a)? YES X NO - N/A 5) INVERTER CALCULATIONS PER ACPV AS SHOWN: - 1 X 1.33A (MAX OUTPUT) X .99 (POWER FACTOR) X.1:25% = 1.645875A / ACPV DRAWN BY: ' AGN CHECKED BY: JAA DESCRIPTION DATE - REV CUSTOMER NAME: JAMES MARSHALL 1767 SPRUCE STREET ' GRIDLEY, CA 9.5948 530-405-7519 nayelig2222@gmail.com SHEET TITLE: ELECTRICAL DIAGRAM &, CALCULATIONS PROJECT #: 2034 MARSHALL, J SHEET M 4.0 DATE: 8/31/17 Y y A� + �r Desi ^n=Driven Advantages I #1 m odule'aesthetics and efficiency' E Q Unmatched module reliability2 No electrolytic capacitors + 25 -year Combined Power and Product Warranty 1 r` 1F Maximize Value for Roof Size system for roof, not string inverter F Optimize performance of each module Expand Deployment Options _ Complex roofs and partial shading j Small systems ! SERIES System expandability + Simplify & Speed Installation ' Optimize System and Installation Efficiency Factory -integrated microinverter , Robust, double -locking AC connectors SunPower" AC Modules, which include a factory -integrated I Design flexibility offsite and onsite SunPower microinverter, provide a revolutionary combination of high No DC string sizing process , efficiency, high reliability, and module -level DC -to -AC power conversion. Fewer installation steps than competing •Three bypass diodes Integrated module -level maximum power point tracking systems Designed specifically for use with SunPower InvisiMount'" and the t Intuitive commissioning SunPower Monitoring System, SunPower AC Modules enable rapid Component of Complete System installation, best -in -class system aesthetics, and intuitive visibility into 1. , Built (Or use with SunPowerO InvisiMountlu system performance. All this comes with the best Combined Power and the SunPower Monitoring System and Product Warranty in the industry.. Superior system reliability and aesthetics M + Output @ 240 V (min./nom./max.) Output @ 208 V (min./nom./max.) SPR -E20.327 -C -AC SPR -E19 -320{ -AC Nominal Power3(Pnom) 327 W 320 W Power Tolerance • +5/-0% +5/-0% Avg. Panel Efficiency' 20.4% 19.9% Temp. Coef. (Power) -0.35%/PC Shade Tolerance •Three bypass diodes Integrated module -level maximum power point tracking Max. Units Per 20 A Branch Circuit @ 240 V Max. Units Per 20 A Branch Circuit @ 208 V No active phase balancing for 3 phase installations ,,12 (single phase) 10 (two pole) Recommended Max. Module Spacing 1.3 in. (33 mm) CUSTOMER NAME: JAMES MARSHALL 1767 SPRUCE STREET GRIDLEY, CA 95948 530-405-7519 nayelig2222@gmail.com SHEET TITLE: MODULE: SPECS PROJECT #: 2034 MARSHALL, J SHEET M If 5.0 DATE: 8/31/17 M CHECKED BY: JAA Output @ 240 V (min./nom./max.) Output @ 208 V (min./nom./max.) SPR -E20.327 -C -AC SPR -E19 -320{ -AC Nominal Power3(Pnom) 327 W 320 W Power Tolerance • +5/-0% +5/-0% Avg. Panel Efficiency' 20.4% 19.9% Temp. Coef. (Power) -0.35%/PC Shade Tolerance •Three bypass diodes Integrated module -level maximum power point tracking M CHECKED BY: JAA Output @ 240 V (min./nom./max.) Output @ 208 V (min./nom./max.) 211/240/264 V 183/208/229 V Operating Frequency (min./nom./max.) 59.3/60.0/60.5 Hz Output Power Factor (min.) 0.99 AC Max. Continuous Output Current @ 240 V AC Max. Continuous Output Current @ 208 V 1.33 A _ 1.54A . AC Max. Cont. Output Power 320 W DC/AC CEC Conversion Efficiency 96.0% Max. Units Per 20 A Branch Circuit @ 240 V Max. Units Per 20 A Branch Circuit @ 208 V No active phase balancing for 3 phase installations ,,12 (single phase) 10 (two pole) • • • . rr by 00 0 on Solar SSEStom. •- '.�` 000-000-000 a�TPARCEL ACRES: CHECKED BY: JAA Solar Cells 96 Monocrystalline Maxeon Gen II Front Glass High -transmission tempered glass with Temp. anti -reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA Impact Resistance rating) Weight 45.5 lbs (20.6 kg) Recommended Max. Module Spacing 1.3 in. (33 mm) • • • . rr by 00 0 on Solar SSEStom. •- '.�` 000-000-000 a�TPARCEL ACRES: Warranties 25 -year limited power warranty 25 -year limited product warranty UL listed to UL 1741, including: IEEE1547/1547a and IEEE1 547.1/1 547.1a Utility Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV Modules (Type 2 fire rating) + Certifications Enables installation in accordance with: 19EC 690.6 NEC 690.12 Rapid Shutdown (inside and outside' the array) NEC 690.15 AC Connectors, 690.33(A) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703): i Integrated grounding and bonding. Class Afire rated PID Test Potential -induced degradation free i aso mm 1107-M Em 1 [43.61n1 10-46m epww M (1.2 in]% 1 'Highest of over 3.200 silicon SOIar panels, Photon M1iodule Airvey. Fib. 2014 - 1 'OT '1 +. .11 rank inTv Module Durability Initialhm Public Report," Fraunhofer CSE, Feb 2013. five out of ' the top eight largest manufacturers were tested. Campeau, Z. el al. "SunPower Module 1558 m _ Degradation Rate; SunPower white paper, Feb 2013. See vv vsun f6'.31n1 7 pap prn•:eccoMfacls for details. ,o • I " s u n p o w e r. e o m Standard Test Conditions (1000 WhW it adiance, AM 1.5.250 Q. 14REL calibration standard: SOMIS ' curt eni. LACCS FF and voltage. All OC voltage is full/ contaiia>d wNNn the module. , ,Z •P'� �f` 'Based onaverage of measured power values during production. 1 Please read the safety and installation instructions for details. —sde-ivv sunpowcccom/facts for more reference-tnfoimauon. • . - For more details, see extended datasheet www.sunpower.com/da[asheets. Document Y, 515217 Rev D /LTR US �„ •' .. ' . Tom, tr ::.�n + _ .r.. ,... .. .. sl/. � Y•. ',,, ... :i - � - _ - -@Ump" 12 .. , SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 6.54 kW DC MODULES: (20) SPR -E20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES = 10 TILT: 30e AZIMUTH: 182° 272° INSTALL TYPE: COMP . SP LEASE # 1176577 SIGNED BY: DRAWN BY: AGN ,• CHECKED BY: JAA Operating Temp. -40° F to +185° F (-40° C to +85° C) Max. Ambient 122° F (50° C) Temp. . • ;Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back ' + Snow: 125 psf, 6000 Pa, 611 /mz front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 m/s) Warranties 25 -year limited power warranty 25 -year limited product warranty UL listed to UL 1741, including: IEEE1547/1547a and IEEE1 547.1/1 547.1a Utility Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV Modules (Type 2 fire rating) + Certifications Enables installation in accordance with: 19EC 690.6 NEC 690.12 Rapid Shutdown (inside and outside' the array) NEC 690.15 AC Connectors, 690.33(A) - (E)(1) FCC and ICES -003 Class B When used with InvisiMount racking (UL 2703): i Integrated grounding and bonding. Class Afire rated PID Test Potential -induced degradation free i aso mm 1107-M Em 1 [43.61n1 10-46m epww M (1.2 in]% 1 'Highest of over 3.200 silicon SOIar panels, Photon M1iodule Airvey. Fib. 2014 - 1 'OT '1 +. .11 rank inTv Module Durability Initialhm Public Report," Fraunhofer CSE, Feb 2013. five out of ' the top eight largest manufacturers were tested. Campeau, Z. el al. "SunPower Module 1558 m _ Degradation Rate; SunPower white paper, Feb 2013. See vv vsun f6'.31n1 7 pap prn•:eccoMfacls for details. ,o • I " s u n p o w e r. e o m Standard Test Conditions (1000 WhW it adiance, AM 1.5.250 Q. 14REL calibration standard: SOMIS ' curt eni. LACCS FF and voltage. All OC voltage is full/ contaiia>d wNNn the module. , ,Z •P'� �f` 'Based onaverage of measured power values during production. 1 Please read the safety and installation instructions for details. —sde-ivv sunpowcccom/facts for more reference-tnfoimauon. • . - For more details, see extended datasheet www.sunpower.com/da[asheets. Document Y, 515217 Rev D /LTR US �„ •' .. ' . Tom, tr ::.�n + _ .r.. ,... .. .. sl/. � Y•. ',,, ... :i - � - _ - -@Ump" 12 .. , SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 6.54 kW DC MODULES: (20) SPR -E20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES = 10 TILT: 30e AZIMUTH: 182° 272° INSTALL TYPE: COMP . SP LEASE # 1176577 SIGNED BY: DRAWN BY: AGN ,• CHECKED BY: JAA DESCRIPTION DATE REV CUSTOMER NAME: JAMES MARSHALL 1767 SPRUCE STREET GRIDLEY, CA 95948 530-405-7519 nayelig2222@gmail.com SHEET TITLE: MODULE: SPECS PROJECT #: 2034 MARSHALL, J SHEET M If 5.0 DATE: 8/31/17 its. r SunPower° Inui4P siMountTM Residential Mounting System Simple and Fast Installation Integrated module -to -rail grounding Pre -assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates even module spacing Simple, pre -drilled rail splice UL 2703 Listed integrated grounding Flexible Design Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle management Customer -Preferred Aesthetics #1 module and #1 mounting aesthetics Best -in -class system aesthetics Premium, low -profile design Black anodized components Hidden mid clamps and end clamps hardware, and capped, flush rails Part of Superior System Built for use with SunPower DC and AC modules Best -in -class system reliability and aesthetics Combine with SunPower modules and monitoring app e Elegant Simplicity SunPower® InvisiMountTM is a SunPower-designed rail -based mounting system. The InvisiMount system i addresses residential sloped roofs and combines faster installation time, design flexibility, and superior aesthetics. I The InvisiMount product was specifically envisioned and engineered to pair with SunPower modules. The resulting system -level approach will amplify the aesthetic and installation benefits for both homeowners and installers. I I I sunpower.com ! u� I SUMPO n�'�ET tr all ,t SunPower° InuisiMountTM Residential Mounting System InvisiMount Gomponen I ages Module* / Mid Clamp and Rail Module* / End Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap f _ I I , I I � i L��, a a• a o. . . Temperature -401 C to 90• C (-40• F to 194° F) Max. Load 2400 Pa uplift 5400 Pa downforce CHECKED BY: JAA Warranties Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug) 106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) a o. . . Temperature -401 C to 90• C (-40• F to 194° F) Max. Load 2400 Pa uplift 5400 Pa downforce CHECKED BY: JAA Warranties Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and Flat Tile Roof Attachment Certifications • Universal Interface for Other Roof Attachments a o. . . Temperature -401 C to 90• C (-40• F to 194° F) Max. Load 2400 Pa uplift 5400 Pa downforce Refer to roof attachment hardware manufacturers documentation *Module frame that is compatible with the InvisiMount system required for hardware interoperability. 0 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respecdve owners. Specifications included In this datasheet are subject to change without notice. sunpower.com Document #509506 Rev B SUNPOWERG by Hooked on Solar SSESORS PARCEL #: 000-000-000 PARCEL ACRES: O.00AC SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 6.54 kW DC MODULES: (20) SPR -E20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES = 10 TILT: 30° AZIMUTH: 182° 272° INSTALL TYPE: COMP SP LEASE # 1176577 SIGNED BY: I 1011 i_ // DRAWN BY: AGN CHECKED BY: JAA Warranties 25 -year product warranty REV S -year finish warranty UL 2703 Listed Certifications Class A fire rating when distance between roof surface and bottom of SunPower module frame Is s 3.5" Refer to roof attachment hardware manufacturers documentation *Module frame that is compatible with the InvisiMount system required for hardware interoperability. 0 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respecdve owners. Specifications included In this datasheet are subject to change without notice. sunpower.com Document #509506 Rev B SUNPOWERG by Hooked on Solar SSESORS PARCEL #: 000-000-000 PARCEL ACRES: O.00AC SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 6.54 kW DC MODULES: (20) SPR -E20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES = 10 TILT: 30° AZIMUTH: 182° 272° INSTALL TYPE: COMP SP LEASE # 1176577 SIGNED BY: I 1011 i_ // DRAWN BY: AGN CHECKED BY: JAA DESCRIPTION DATE REV CUSTOMER NAME: JAMES MARSHALL 1767 SPRUCE STREET GRIDLEY, CA 95948 530-405-7519 nayelig2222@gmail.com SHEET TITLE: RACKING SPECS PROJECT #: 2034 MARSHALL, SHEET #: J 6.0 DATE: 8/31/17 a IFQ -3 _v'-, "4-r' - Q v vp, r TI" X Tlie :Next rfo; n Gend'at in Flashed 'Mounts for Shirigle Ro6fg'.F,' 1905 E 5th St., Ste. A, A hku�M 7- oofs F �{ �, � i•r.. :�; .ti a .� �� ��� m 0 "A - & - tall for �!.z Versatile WuminUrn"UA Y - Al AL S&r'Mied L-Poot;pllowg� Flashing designed -10 redirect_- ";" 4 dvx?-�t,.- A W� multiple configUrationg water flow ng,on en er" - "�' - - h rail mouhti -i s e % fo EZ-7Mount L=Foot Kit �n#le Roofs Kit #.K10068- - " 001 NAll kits66Me complete with the following parts: S A 1,A1 Shoe 1- s. NPrtN 0i% I Fbbt- 5-0 ux , Pana A20064001 ex p .:Iz-Bo t 3/ .8 �167x'3/4-' H' 'c X arti`66062-0&L Pat . r# 00 '4 Wj Varicouver, WA 98661 1 Phone: 360-844.0048 wwwsuninodoxorn 5th St., Ste. A ri.'- 'Vdr-fC6-E Uv'er,-WA-9966i Ph 6neA60-84"o :vv-'wW'.su'-Mdd6c-o-"m } C. SUNPOWER bv.Hooked on Solar SSESORS PARCEL* ' 000-000-000 PARC .. e ... _ .. — C • EL ACRES: I3.0 Grounding Overview, _r o.00Ac If you are installing SunPower AC Modules on the SunPower InvisiMount mounting system (or any mounting system that is Listed to UL 2703 for bonding—not just for fire classification), no additional ' . Warning. Ensure that you fully understand the grounding aspects in this section before prgrounding wire is required: A. proceeding. grounding This section is intended to provide a well-rounded understanding of all aspects of grounding for SunPower The SunPower AC Module is one of the components that bonds all of the metallic non-current carrying 96 -Cell AC Modules when they are installed with the SunPower® InvisiMounf" Residential Mounting System; ' components in the system, and is Listed to UL 1741. it contains excerpts from the SunPower,96-Cell AC Module Design and Installation Guide (#515791; unreleased); and the SunPower AC Module Safety and Installation Instructions (#51744); as well as • . As part of UL 2703, only AC equipment grounding requirements apply—not DC system grounding - references to the applicable NEC Articles and UL Standards. - requirements nor DC equipment grounding requirements. a a The InvisiMount,system is Listed to UL 2703 for integrated grounding; SunPower AC Modules area bonding The equipment grounding conductor (EGC) that's built into the module's AC cable system is sized Component and are Listed to UL 1741. If you are installing SunPower AC Modules on the InvisiMount appropriately and meet's all of the AC equipment grounding requirements for the system. i system, no additional grounding hardware, lugs, or copper wire arerequired,on the roof.. The AC dedicated branch circuit wiring from the readily accessible disconnect to the array must include an equipment grounding conductor (EGC) in the same raceway or cable as the AC circuit conductors. This _ i EGC must be connected to the+ reen conductorf th t ' n bl wh' • rt f th AC d 1 g O e. rand t 10 Cd e, ICh IS pa 0 e mo u e , cable system. w • If a module is removed from a circuit, you must install a temporary EGC to bridge the gap by inserting an AC extension cable or other means,.in order to maintain effective ground continuity to subsequent modules. •' Because the modules are connected in a "daisy chain" fashion, disconnecting one module from the circuit using the AC cable removes voltage and ground from the other downstream modules in the circuit. Extreme care should be taken to ensure that no other energized sources are adjacent to these ungrounded modules, otherwise auxiliary grounding methods must be applied. y • Because the DC power, is internal to the module, a grounding electrode conductor (GEC) for the module or array is not required. The existing AC GEC at the utility service serves as the NEC -required GEC for the structure. • The AC cable grounding path has been tested by a NRTL, and its electrical continuity from the AC cable ground pin to the module frame has been certified. • The AC module interconnecting cable system provides an internal EGC for grounding the AC modules. It is the installer's responsibility to ground any metallic mounting structure according to local code. Installers must ensure that whichever mounting system they choose is then grounded according to the instructions of that mounting system. Some mounting systems can be bonded to the AC modules with listed devices. Consult the module's included safety instructions for details. • Neither the AC modules nor the array require a GEC, and the neutral conductor within the AC module is isolated from ground. The AC module must be connected to a dedicated AC branch circuit with the neutral conductor referenced at the building service entrance. • The AC interconnecting cable system attached to each module's microinverter is fully insulated and includes an internal EGC. The grounding pin is longer than the others in the plug. Document #515791 RevA 24 SunPower Proprietary Document #515791 RevA 25 SunPower Proprietary . FTM L -SCALE, SINGLE-PHASE PV SYSTEM SIZE: 6.54 kW DC MODULES: (20) SPR -E20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES 10 TILT: 30* AZIMUTH: 182° 272° INSTALL TYPE: COMP SP LEASE #,1.176577 r SIGNED BY: DRAWN BY: AGN CHECKED BY: JAA DESCRIPTION DATE REV CUSTOMER NAME: JAMES MARSHALL 1767 SPRUCE STREET GRIDLEY, CA 95948 530-405-7519 Inayelig2222@g . mail.com SHEET TITLE: , ". GROUNDING METHOD PROJECT M 2034 MARSHALL, SHEET #: J 8.0 DATE: . • 8/31/17 - - - - __ _ - ----- SUNPO_ WERc by Hooked on Solar .Sa1kK4m,pMtagvmb, ,Sari401mnpaara�,sbn ' • - NEC 690.31(E)(3),(4) Wiring Methods, Direct -Current Photovoltaic Source NEC 690.5(C) Ground Fault Protection, Labels and Markings - and Output Circuits Inside a Building, Marking or Labeling Required A warning label shall appear on the utility -interactive inverteror be applied by the ASSESORS PARCEL M Marking or Labeling Required. The following wiring methods and enclosures that contain - installer near the ground -fault indicator at a visible location, stating the following: 000-000-000 unction Box & ConduitRacewa s' ' ®®�® yPV power source conductors shall be marked with the wording "Photovoltaic Power WARNING PARCEL ACRES: NEC 69031(E)(3)- CONDUrT/ALL JUNCTION BOXES-._ - Source"by means of permanently affixed labels or other approved permanent marking: - ELECTRIC SHOCK HAZARD ` 0.00AC L ��®® 1. Exposed raceway, cable trays and other wiring methods IF A GROUND FAULT IS INDICATED, WARNING2. Covers or enclosures of pull boxes and junction boxei NORMALLY GROUNDED CONDUCTORS MAYBE UNGROUNDED AND ENERGIZED • • • • • • 3. Conduit bodies in which an of the available conduit openings are unused ~ _ _ YWhen the photovoltaic system also has batteries, the same warning shall also be applied ) • % The labels or markings shall be visible after installation. Photovoltaic power circuit labels by the installer in a visible location at the batteries. - NEC 690.35(Fl -UNGROUNDED SYSTEMIUNCTION BO%ES shall a pear on eve section ofthe wirin s stem that is se arated b enclosures all IBTS INTERPRETATION• A I b I h II b lied t h I h• / 7 P rY 9 y P Y . warning a e s a a app Ie o t e nverter or near t o WARNING ��®® partitions, ceilings or floors. Spacing between labels or markings, or between a label and ®I ground fault indicator describing the hazard that would exist in the event of a i a marking, shall not be more than 3 m (10 ft.). Labels required by this section shall be ground fault. SHOCKELECTRIC • suitable for the environment where they are installed. , THE DC CONDUCTORSOF 1 �', �,d IBTS INTERPRETATION: This code is specific to DC circuits to be identified as a - PHOTOVOLTAIC r t - T Photovoltaic Power Source. This includes DC conduit, Junction Boxes, and NEC 690.14(c)(2) Additional Provisions Requirements for Disconnecting UNGROUNDED • MAY BE3 : Combiner Boxes that are inside or connected to the building structure. Means, Markings f +ENERGIZED. ,.Rapid: SI IutdOWn' . - y: Each photovoltaic system disconnecting means shall be permanently marked to identify - _- it as a photovoltaic system disconnect , - - ( y! ' •' ' 4 NEC 690.35(F) Ungrounded Photovoltaic Power Systems , • . + IBTS INTERPRETATION: Required at any disconnecting means including AC DC Disconnects The photovoltaic power source shall be labeled with the following warning at each ® Disconnect, DC Disconnect, and Main Service Panel. Also required at Inverters with • r) junction box, combiner box, disconnect and device where energized, ungrounded circuits integrated disconnects and subpanels. This label should be applied directly to the - ED NEC 690.17 4 GROUNDSYSTEMS - S' may be exposed during service: component and does not apply to the "line of sight" provision. The DC or AC - WARNING reference is not specifically required., WARNINGr - - ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS SHOCKELECTRIC HAZARD. + * E ` { _ OF THE PHOTOVOLTAIC SYSTEM ARE -NEC 705.12 (D)(4) Point of Connection, Utility -Interactive Inverters, .• ••TERMINALS. fs j UNGROUNDED AND MAY BE ENERGIZED. � rr 't'' "� •; •�. , •r Markings ' TERMINALS ON BOTH LINE ANDIBTS INTERPRETATION: This label should be installed for Ungrounded Photovoltaic Equipment containing overcurrent devices in circuits supplying power to a busbar or • • . • • 1 ®I Systems on DC components where ungrounded circuits may be exposed during conductor supplied from multiple sources shall be marked to indicate the presence of . • • • • • - - I service. This includes the junction box, combiner box, DC disconnect, and Inverter. g nrs,,= 4 1 . • - - all sources. SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 6.54 kW (DC)' MODULES: (20) SPR -E20 -327 -C -AC CIRCUITS: , CIRCUIT #1 ACPV IN SERIES = 10 CIRCUIT #2 ACPV IN SERIES = 10 TILT: AZIMUTH, 30' 182' 272' INSTALL TYPE: COMP _ IBTS INTERPRETATION: This label is required on the main service panel to • NEC 69035(F)- UNGROUNDED SYSTEMS ...• •� , I `t M• - '.f 1 •'� it ,).. y s ' identify that the panel is energized from multiple sources, the Utility and a 1.NEC 690.17 Switch or Circuit Breaker ®I Photovoltaic system. Label is also required on subpanels, fused AC disconnects, SP LEASE # 1176577 )II or an other component housing an overcurrent protective device. WARNING +' . \ g- # 1 The disconnecting means for ungrounded conductors shall consist of manually operable y P 9 1111 switch(es) or circuit breakers(s) complying with all ofthe following requirement: SHOCKELECTRIC - • ' ! 1. Located where readily accessible THE •CONDUCTORS• , 705.12(D)(7) Point of Connection, Inverter Output Connection PHOTOVOLTAIC 4�s 2. Externally operable without exposing the operator to contact with live parts , t / ^ .,y' Unless the panelboard is rated not less than the sum ofthe ampere ratings of all UNGROUNDED • t k - 3. Plainly indicating whether in the open or closed position over -current devices supplying it, a connection in a panelboard shall be positioned at the SIGNED BY: • • : 4. Having an interrupting rating sufficient for the nominal circuit voltage and the opposite (load) end from the input feeder location or main circuit location. The bus or r . - - current that is available at the gine terminals ofthe equipment conductor rating shall be sized for the loads connected in accordance with Article 220. • NK 690.14(C)(2) ' _ .' _ � Produetion'Meter • Main Service Panel Where all terminals ofthe disconnecting means may be energized in the open position, a In systems with panelboards connected in series, the rating of the first overcurrent device directly to the inverter(s) be in ® . o warning sign shall be mounted on or adjacent to the disconnecting means.The sign shall connected output of a utility -interactive shall used NOT A CODE REQUIREMENT NEC 70s.12(D)(7)- NEAR PV BREAKER be clearly legible and have the following words or equivalent: the calculations for all busbars and conductors. A permanent warning label shall be 0 0 SHEET TITLE: SAFETY LABELS - WARNING applied to the distribution equipment with the following or equivalent wording: ' Igge S ELECTRIC SHOCK HAZARD. WARNING , OUTPUf CONNECTION DO NOTTOUCH TERMINALS. TERMINALS - INVERTER OUTPUT CONNECTION NEC 69053 t r r ' • • •RELOCATE ON BOTH THE LINE AND LOAD SIDES IS DO O NOT R LOCENT DEVICE • PROTECTION MAY BE ENERGIZED IN THE OPEN POSITION. 'r • • • . Exception: A connector shall be permitted to be used as an AC or a DC disconnecting means, provided that it complies with the requirements of 690.33 and is listed and IBTS INTERPRETATION: This label must be used when the sum of the Photovoltaic system breaker/fuse and Main Service Panel breaker/Fuse is greater than 100% of NEC 705.1200), 690.56(8) -ON PANEL COVER . = the busbar rating. It is not required if the sum of those two breakers supplying the r . AC Disconnects identified for the use. f ;, busbar is equal to or less than the busbar is rated for. ' - y .. -. - x NEC 690.14(C)(2)POWER IS BEING SUPPLIED THIS®I PANELFROM THEUTILITY � , A' IBTS INTERPRETATION: This label should be installed on the covers of the disconnecting means that may be energized In the open position. This includes combiner boxes, DC disconnects and inverters with integrated DC disconnects. Example A: 200A maximum rating on busbar. 200A main breaker+20A back fed PV breaker= label required '- Example B: 220A maximum rating on busbar. 200A main breaker+20A back Inverter. • o ® Should be installed on grounded and ungrounded systems. , fed PV breaker = no label required. . -„- _ NEC 690.5(C)- GROUNDED SYSTEMS • LOCATED: 2 p -DISCONNECT Location description or map here NEC 690.56(9) Facilities with Utility Services and PV Systems WARNING.NEC 690.53 Direct -Current Photovoltaic Power Source Buildings or structures with both utility service and a photovoltaic system shall have a ' NEC 690.54 • A permanent label for the direct-current photovoltaic power source indicating items 1 permanent plaque or directory providing the location of the service disconnecting means SHOCKELECTRIC HAZARD VOLTAGE: NEC 690.14(C)(2) - NEAR PV BREAKER through 5 shall be provided by the installer at the photovoltaic disconnecting means: and the photovoltaic system disconnecting means if not located in the same location. IF A GROUND INDICATED, _ NORMALLY• . • . MAY BE UNGROUNDED • • . . r. S O 0 1. Rated maximum power -point current 2. Rated maximum power -point voltage IBTS INTERPRETATION: All system disconnects on a Utility -Interactive PV System, ® are required to have this label identifying where other system disconnecting means r NEC 705.12(D)(4) -ON A LINE SIDE TAP • ® 6 3. Maximum system voltage are located if not visible from either component. ' • ' •• - • InformatiollalNote to3.: See 690.7(A) for maximum photovoltafcsystem voltage. NEC 690.35(F)- UNGROUNDED SYSTEMS • • • - NEC 690.54 - ON PANEL COVER 4. Short-circuit current InformalionalNoteto4.:5ee690.8(A)forcalcularionofmaximumcircuitcurrent Reprinted with permtssion from NFPA 70• - 2014, Natlonol EfeadmlCede, copyright O 2013, Natlonal Fire Protection ' 5. Maximum rated output current ofthe charge controller (if Installed) Association, Quincy, MA. This reprinted complete p p position of the NFPA on the referenced subject which is represented only by the standard In its entirety, SHOCKELECTRICAL • " Informational Note: Reflecting systems used forirradiance enhancementmay result in • '' increosedlevefsofoutputcurrent and power. ® CONTACT- Q CONNECT ' IBTS INTERPRETATION:This code reference describes the label content to be ' ®I present at any DC disconnecting means of a system. If applicable, this includes www.ibts.org g facebook/IBTSsolar Doyle I Program Director The purpose of this graphic Is to provide a reference guide to solar photovoltaic system labeling requirements In accordance with the Inverters with an integrated DC disconnect. .Chris -Solar G @IBT$_5olar ,>' 2011 National Electric Code (NEC), National Fire Protection Association (Copyright 2010), as interpreted by the Institute for Building edoyle@ibts.org I 512.452.8899 • Technology and Safety (IBTS). Users should always follow the code requirements and Interpretations for specific placement of labels of M IBTS - Solar PV the presiding Authority Having Jurisdiction (AHI). NFPA 70•, National Electrical Code- and NEC* are registered trademarks of the ® IBTSor , National Fire Protection Association, Quincy, MA. g .. f m Institute for. Building Technology and Safety, 2014 t S O Institute for Building Technology and Safety, 2014 DRAWN BY: ' AGN CHECKED BY: JAA -DESCRIPTION DATE REV CUSTOMER NAME: JAMES MARSHALL 1767 SPRUCE STREET " GRIDLEY, CA 95948 530-405-7519 nayelig2222@gmail.com SHEET TITLE: SAFETY LABELS PROJECT M 2034 MARSHALL, J SHEET #: 9•� DATE: 8/31/17 • 1 t 4