Loading...
HomeMy WebLinkAbout007-230-0070 4 BUTTE COUNTY AREA DEPARTMENT OF -DEVELOPMENT SERVICES 4 INSPECTION CARD MUST BE ON JOB SITE, .24 Hour Inspection Line (IVR) : 530.538.4365. (Cut off time for inspections is Spm) Development Services cannot guarantee inspections on the date requested Office: 530:538.7601 Fax:53 Permit No: B 17-2377 Issued: 10/6/2017 APN: 007-230-007 Address: 4325 CABALLO WAY, CHICO Owner: MARCH LESLEY E'. Permit Type: SOLAR ROOF -RES , Description: Install 14.8kw roof mount to existing meter. u.3sts. i ia3 www.tsuttet,ounty.netiaas Flood Zone: None SRA Area: No SETBACKS for Zon*ng. AG. SRA. PW T Front: Centerline of Road: Rear:. SRA: , Street: AG: " Interior Total Setback from Centerline"of Road: ALL PLAN REVISIONS MUST BE APPROVED BY. THE COUNTY BEFORE PROCEEDING 1 . it t t t .l. i Insvection T e IVR - INSP. DATE Setbacks 131 ; Foundations / Footings 111 ` Pier/Column Footings 122 Eufer Ground 216 Masonry Grout t 120 Setbacks ` 131 Do Not Pour Concrete Until Above are Sign d .Pre -Slab 124 Gas Test Underground/floor s 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer- .136 Under Floor Plumbing 412 Under, Slab Plumbing 411 ._ Blockin /Under inin 612 Tiedown/Soft Set System 611 Do Not Install FloorSheathing or Slab Until Above Signed. ShearwallB.W.P.-Interior 134. Shearwall/B.W.P.-Exterior 135 Roof Nail/Drab Trusses 129 Manometer Test. . .605 Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153' Rough Plumbing -406 Rough Mechanical 316 . Rough Electrical 208 4 -Way Rough Framing - 128 Gas Piping House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed , Permit final 802 &A M) Electrical Final 803 Mechanical Final. 809 - Plumbing Final 813. Fire Sprinkler Test or Final 702 Swimming Pools Inspection Type.' •IVR : INSP DATE T -Bar Ceiling 145 Stucco Lath 142. Swimming Pools Setbacks ` 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 - Blockin /Under inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 _ Underground Electric 218 Sewer "407 ' Underground Water 417 ` Manometer Test. . .605 Continuity Test 602' Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: .Length x Width: Insignia: Public Works Final 538.7681 Fire De artrrfent/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final 'PROJECT FINAL t 7 • 'rroject f anal is a Certificate of Occupancy for (Kesidential Onr)q PERMITS -BECOME NULLAND VOID I YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU NIAY PAY FOR A I YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION PROJECT OWNER: SCOPE:'o'efremwow _ MARCH, LESLEY INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS 4325 CABALLO WAY ROOF, MOUNTED IN ACCORDANCE WITH ALL CHICO, CA 95973 APPLICABLE BUILDING CODES SPECIFICALLY APN:007-230-007 PH#:530.570.5417 REFERENCING THE 2016 CALIFORNIA ELECTRICAL EMAIL:Iesmirch@netzero.net CODE/ 2014 NEC USING THE FOLLOWING SPECIFIC LEASE #:1153109 EQUIPMENT: CONTRACTOR: 1. MODULES: SUNPOWER ' ` (43) SPR -X21 -345 -C -AC ATTACHMENT' 14.84kW SYSTEM ALTERNATIVE ENERGY SYSTEMS INC. INVERTER SPECS 13620 HIGHWAY 99 786 SQFT COVERED CHICO, CA 95973, ", WIRE CALCSf _ 2. INVERTER(S): SUNPOWER:. CSLB: 853351 C-10, C-46 (43) MODULE INTEGRATED 320W EACH ' BUILDING JURISDICTION:" - SITE MAP a x. ;N+�s BUTTE COUNTY DEPT. OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 ! �` OFFICE#: (530) 538-7601 FAX#: (530) 538-2140 MON-FRI 8AM-3PM� + 1 r+ INSPECTION LINE: (530) 538436528, �` —� J ' -Y• ` REQUESTS PHONED IN BY 2PM WILL BE INSPECTED THE NEXT BUSINESS DAY m m ° 13620 H WY 99 A m S MARCH, LESLEY Ener For G o 9Y CHICO, CA 95973 o a " 4325 CABALLO WAY PHONE#: (530) 345-6980 CHICO CA 95973 000 . ' p D " FAX#: (530) 892-2360 °z Z o ° APN:007-230-007 PH#:530.570.5417 Alternative Energy Systems Inc. Az design@ sola renergyforlife.com *-6 Irt- PAGE # CONTENT PV -1.0 SCOPE " PV -2.0 SITE PLAN , PV -3.0 ARRAY LAYOUT PV -4.0 ELECTRICAL- DIAGRAM PV -4.1 LABEL DIAGRAM PV -5.0 GENERAL NOTES ATTACHMENT' MODULE SPECS INVERTER SPECS • RACKING'SPECS_ WIRE CALCSf (N) AC DISTRIBUTION PANEL - (N) MONITQRING (E) PGE YMETER & �: (.E) MALN SERVICE PANEL ( , N AC DISCONNECTIL f. F �-- MODEM AND RO_ UTER LOCATION O } [[,, 1 •}� �'" fie. 6 l'i--- % F t -- Py' d E POOL , J S (E) AC 7�z PANEL �s _ a f (E) RESIDENCE y dF } E COMPOSI'TIQN ROOF W/WOOD TRUSSES l� x SITE PLAN m ^o a /y,. MARCH, LESLEY 13620 HWY 99 EnergyF-""" CHICO,CA91973 (i s m G i n ? 3 o m 4325 CABALLO WAY 4 PHONE#: (530) 345-6980 IIS ° Z aw'Aw D p_= R CHICO, CA 95973 ®® FAX#: (530) 892-2360 . y dF } E COMPOSI'TIQN ROOF W/WOOD TRUSSES l� x SITE PLAN m ^o a S MARCH, LESLEY 13620 HWY 99 EnergyF-""" CHICO,CA91973 m G i n ? 3 o m 4325 CABALLO WAY 4 PHONE#: (530) 345-6980 IIS ° Z a s N Z D p_= R CHICO, CA 95973 ®® FAX#: (530) 892-2360 . ° m Z A o ° � APN:007-230-007 PH#:530.570.5417 Alternative Energy systems Inc. design@solarenergyforlife.com NOTES LALL ROOF. PENETRATIONS " TO -BE -72 O.C. MAXIMUM • ATTACHMENTS MAX 72" OC s - ARRAY LAYOUT •, r m 6-0" s MARCH, LESLEY 13620 H WY 99. ; , ' RAFTERS 24" OC a P m - CHICO, CA 95973 _ _. _ K s Z n a z `3 o o 4325 CABALLO WAY , PHONE#: (530) 345-6980 o ? a CHICO, CA 95973 -" ®�� o a o a IJ, .o 0 z Z APN:007-230 007 PH#:530.570.5417 Alternative Energy Systems Inc. ' design@solarenergyforlife.com o 38'-7"* FIRECODE` f I T1 I NOTES LALL ROOF. PENETRATIONS " TO -BE -72 O.C. MAXIMUM = - ARRAY LAYOUT •, o m o s MARCH, LESLEY 13620 H WY 99. ; a P m Energy ForLile CHICO, CA 95973 K s Z n a z `3 o o 4325 CABALLO WAY PHONE#: (530) 345-6980 o ? a CHICO, CA 95973 ®�� FAX#: (530) 892 2360 $ - z Z APN:007-230 007 PH#:530.570.5417 Alternative Energy Systems Inc. ' design@solarenergyforlife.com AC -2 AC -3 AC -1 , } - ON ROOF w/ (1) 3/4" EMT w/ (3) #6 THWN-2 CU. & M (1)44-3 WIRE NCABLE CU. - SERVICE VOLTAGE • " (4)TRANSITION CABLE(S) CU. GRD. WIRE RUN: 60' * IMAX: 72A . 120 =1- =2 0 - 120V=N•L2-L3=NAV - WIRE RUN: S' AC -1 �. + WI ETHWN-2 WIRE RUN: 10' _ _ _ •. ., ,,.• NAV=N-L3-LI=NAV' - IMP: 20A (4) #10.2 WIRE NM CABLE CU. ' IMAX: 72A _ , _ - f _ a - . WIRE RUN: 30' IMAX: 20A =� - 4 METER 1 - - AC -DISC AC -0 , 1 .100A/ 1P/ 240V • , , ExISITNG CUTLER HAMMER:DG223URB k x• (11) PV MODULES/INVERTERS ' SUN POWER:SPR-X21-345-C-AC .. 'C 1.33A/1P/240V —= '(11) PV MODULES/INVERTERS ' ' _; T 20A ` y s SUNPOWER: SPR -X21 -345 -C -AC' . � � -� -� 1P -. Y: _�. J. •. � : � , �, _. v - at _ _ 1.33A/1P/240V 240V y .... - i - 1F' 220X LABEL -SOLAR ONLY 1P' ' •11) 1 240V 80A ' ( PV MODULES/INVERTERS7,;E )-BOX F 20A + - .. - _ 1P- �- SUNPOWER:SPR-X21-345-C-AC. _ _. ,,, w ' 1P r. • . _ 240V . 1.33A/1P/240V•' - * .. .� ,••, . __ (E)AC DISTRIBUTION PANEL 225A/ 1P/ 240V -_ (E) AC SERVICE PANEL 1P/ 240V ' 2 s;, ~. SCIR:'10000 (10) PV MODULES/INVERTERS ' r , ., METER#: 1007766791 SUNPOWER: SPR -X21 -345 -C -AC ..' - � _ Y M11.33A/1P/240V •. = 15A (N)AC DISTRIBUTION PANEL S • j - - - - ` - ^ - _ - '• r ' 125A/ 1 P/ 240V - , - / 1 //�) O/O RULE _ •• _ `• AC -MONITORING .. i G..O (1) 1/2" EMT./'_ ..,�. (2)#14 THWN-2CU. & r ` DOWNSIZE MAIN BREAKER IN ' (1)#14 THWN-2 CO. GRD. ` N WIRE RUN: 10• ACCORDANCE TO NEC 2014 - CAT ARTICLE 705.12(D)(2) „ , • ._ � . •SUNPOWER PVSSX � -5 ��� � + - _ l . , r j ROUTER + •, - ELECTRICAL DIAGRAM `.._ . _o m MARCH, LESLEY 13620 HWY 99 ; I p 0 m o I - m . Energy For LIfe CHICO, CA 95973 n `r" < C) I 2 !� > m• 3;00 3° 4325 CABALLO-WAY - I ®�� PHONE#: (530) 345-6980 o 3 S A < p n r CHICO, CA 95973 FAX#: (530) 892-2360 r C)' 0 2 ° -230 007 PH#:530.570.5417APN:007 `Altebrnative Energy Systems Inc. , design@ sola renergyforlife.Com , PV ARRAY • . AC DISCONNECT _ - MAIN ' ' SUB PANEL 4 } METER + + R� i MM 1 - RASE tali , • . • ' • VOLTS , rs. . i c " ' • . AMPS = ' -PHASE ' • - * tt , VOLTS t - -WARNING UTILITY INTERACTIVE POWER FLOWING THROUGH THIS PANEL KW SOLAR GENERATOR AC OPERATING VOLTAGE: WARNING PHOTOVOLTAIC SYSTEM EQUIPPED DUAL POWER SUPPLY < WITH RAPID SHUTDOWN PHOTOVOLTAIC SYSTEM PER NEC 690.54 Interactive Point of I Interconnectin installed at all Electrical `� Per:NEC 705.10;. Point of Connection, 4L , 1 Located On Main Service Panel " - } Distribution Panel covers that porvide a " t path from PV to Utility. AC PHOTOVOLTAIC ' '... • n A FOR UTILITY OPERATION , • Per NEC 690.14, Disconnection means at the single AC Disconnect or Main Breaker. •SOLAR .. NOT RELOCATE Solar breaker label @ any breaker passing - r Bi -Directional Power • _ ,, � ... ^ , .. -I .. • ' � � LABEL DIAGRAM , o m . n 20 HWY 99 MARCH LESLEY or o o m Energy Life CH6CO3CA95973 G z z 3 4325 CABALLO WAY o h o CHICO, CA 95973 ; PHONE#: (530) 345-6980 3 << '° D = FAX#: (530) 892-2360 m Z' APN:007-230-007 PH#:530.570.5417 Alternative Energy Systems Inc. - design@solarenergyforlife.com'' ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND FIRE DISTRICT REGULATIONS. 1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. 2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM. 3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION BOXES, COMBINER BOXES, AND SWITCHES. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ART.250,690. 5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES. 6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING. 7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF NEC 408.16(F) (408.36 IN 2014 NEC. 8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK. 9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75" C MINIMUM. 10. NEC ART. 690.14. - SEE SHEET RE -4.1 FOR LABEL DIAGRAM 11. NEC ART. 690.53. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK HAZARD - DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAY BE ENERGIZED IN THE OPEN POSITION". 13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED. 14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS LOCATED ON DWELLINGS PER 2014 NEC ART.690.17. 15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT SYSTEMS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER 2014 NEC ART.210.4D 16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS. 17. PHOTOVOLTAIC SOURCE CURRENTS MUST BERATED AT BOTH 125% OF THE PARALLEL MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL OF 156% OF THE LOAD. 18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE NOT IN THE SAME LOCATION PER 2014 NEC ART.690.56. 19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05, CHAPTER 13. 20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS. 21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS INSTALLED AS SPECIFIED IN THESE DRAWINGS. 22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE, CAPACITY, APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL OR PHYSICAL PLACEMENT. 23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL UTILITY. 24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2014 NEC 690.5(H) AND IN ACCORDANCE WITH 2014 NEC 705.10. 25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS FOR ALL INSPECTIONS. ALL 1 BOXES WILL BE OPENED UPON REQUEST. 26. SMOKE AND CARBON MONOXIDE ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314 R315 m n 0 0 0 m MARCH, LESLEY 13620 HWY 99 Energy For Life CHICO, CA 95973 < Z 9 Z p. K 4325 CABALLO WAY PHONE#: (530) 345 6980 s z Z 0 '< 9 > " CHICO, CA 95973 y� ®®® FAX#: (530) 892-2360 ° m APN:007-230-007 PH#:530.570.5417 Alternative Energy Systems Inc. design@solarenergyforlife.com ;June 22:2017 -To Whomlit May -Concern, In'o�der to meet future advanced grid requirements; SunPower® is transitioningfrom Type C AC,modules to Type D AC. modules—The purpose of this letter is to demonstrate the mechanical and electrical equivalency of Type C AC modules _ and Type D AC modules. Type D AC modules are drop'in replacements for Type C AC modules and 'are available,at the same DC and AC power. levels. Type D AC modules have the same form,�fit, and function as Type C AC modules. The AC electrical output specificatioris'of Type C'AC modules and Type D'AC modules are equivalent, ensuring interchangeability for -AC conductors, overcurrent protection devices, and, grounding.' , SunPower Type D AC modules are certified per U.L 1741 SA to the following SRDs: IEEE 1547, IEEE 1547a, and CPUC Rule 21 Phase 1"These additional certifications and functionality, enable Type -D AC modules to meet California CPUC Rule 21 Phase'1 smart inverter requirements. The following,table lists the -Type C AC module models and their respective Type D equivalents, as of the date of this letter: . Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout, structural_ loading, electrical design, or interconnection are required. Should,you have any questions or concerns, please contact SunPower Technical Support at 1-800-786-7693. :Best,Regards Matt Mayberry a 'Director, Residential Product Management • • " - s. 3 + E19 -320 -C -AC E19 -320 -D -AC .E20=327 -C -AC, •' ,, ,` '' E20 -327 -D -AC X21-335=BLK-C'AC ' ".. ' r X21-335-BLK-D=AC X21 -335 -C=AC ' X21 -335 -D -AC X21=345 -C -AC - , .' :. X21-345-D=AC X22 -360 -C -AC ' ' 1 - X22 -360 -D -AC - Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout, structural_ loading, electrical design, or interconnection are required. Should,you have any questions or concerns, please contact SunPower Technical Support at 1-800-786-7693. :Best,Regards Matt Mayberry a 'Director, Residential Product Management • • " - s. 3 + Design -Driven Advantages #1 module aesthetics and efficiency Unmatched module reliability2 No electrolytic capacitors 25 -year Combined Power and Product Warranty Maximize Value for Roof y Size system for roof, not string inverter Optimize performance of each module Expand Deployment Options' Complex roofs and partial shading Small systems System expandability Simplify & Speed Installation t Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite, No DC string sizing process Fewer installation steps than competing < systems Intuitive commissioning Component of Complete System Built for use with SunPowerO InvisiMount"I and the SunPower Monitoring System Superior system reliability and aesthetics I ' �• Mme. �� (0 I I I I I I I EL I I I l I i i I I l I I X SERIES Optimize System and Installation Efficiency SunPower" AC Modules, which include a factory -integrated SunPower microinverter, provide a revolutionary combination of high efficiency, high reliability, and module -level DC -to -AC power conversion. Designed specifically for use with,SunPower InvisiMountT"" and the SunPower Monitoring Sysiem, SunPower AC Modules enable rapid installation, best -in -class system aesthetics, and intuitive visibility into' system performance. All this comes with the best Combined Power .and Product Warranty. ZY-1, sunpower.com - } ��� h =i. ;. Y{{� ..�i t � :r ,.., 1 �, _. - 11/►�,,V./11//�,, 1111�1w`V1ff,,1 � ©��\\��'/�/��\��'/�}��y�������� � O i 5. -• 0•- 41111111111 • Output @ 240 V (min./nom./max.) Output @ 208 V, (min./nom./max.) SPR -X21 -345 -C -AC ' SPR -X21 -335 -C -AC Nominal Power 3(Pnom) 345 W 335 W Power Tolerance =5/-0% +5/-0% Avg. Panel Efficiency° . - 21.5% 21.0% ' Temp. Coef. (Power) -0.30%/°C Shade Tolerance Three bypass diodes ; Integrated module -level maximum power point tracking 5. -• 0•- 41111111111 • Output @ 240 V (min./nom./max.) Output @ 208 V, (min./nom./max.) 211/240/2'64 V ,183/208/229 V Operating Frequency (min./nom./max.) • 1 59.3/60.0/60.5 Hz Out Power Factor (min.) u 0.99 AC Max. Continuous Output Current @ 240 V AC Max. Continuous Output Current @ 208 V 1.33 A 1.54 A' . AC Max. Cont. Output Power 320 W DC/AC CEC Conversion Efficiency. 96.0% Max. Units Per 20 A Branch Circuit @ 240 V Max. Units Per 20 A Branch Circuit @ 208 V 12 (single phase) 10 (two pole) - 280 mm ' [11.02 in] 1107 mm - ' r [43.6 in] 1046 mm ... , [41.2 in] 30 mm II.2 in] 'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 2#1 rank in "PV Module Durability Initiative Public Report," FraAorer CSE, Feb 2013. Five out of the r 1558 mm top eight largest manufacturers were tested. Campeau, Z et al. "SunPower 4lodule Degradation Rate.", f ' [613 int I - SunPower white paper, Feb 2013. See www.sunpower.convfaci_s for details. =standard Test Conditions (1000 W/mz irradiance, AM 1.5, 2S1 C). NREL calibration standard_: SOb1S current LACCS FF and voltage. Al DCvolWe is fully contained within the module. Please read the safety and installadon instructions for details. `Based on average of measi,red pov:er values during production. See mvwsunpower.com/facts for more reference information. For more details, see extended datasheet:,Aww.sunpower.com/datashee[s. w a Document # 515215 Rev B /LTR US -• 0•- 41111111111 • Operating Temp. -40° F to +185° F (-40° C to +85° C) Nlax. Ambient Temp. 122° F (50° C) Max. Load Wind: 62 psi, 3000 Pa, 305 kg/m2 front & back Environmental Snow: 125 psf, 6000 Pa, 611 ' g/m2 front Impact Resistance, 1 inch (25 mm) diameter hail at 52 mph (23 Frame m/s) - 280 mm ' [11.02 in] 1107 mm - ' r [43.6 in] 1046 mm ... , [41.2 in] 30 mm II.2 in] 'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 2#1 rank in "PV Module Durability Initiative Public Report," FraAorer CSE, Feb 2013. Five out of the r 1558 mm top eight largest manufacturers were tested. Campeau, Z et al. "SunPower 4lodule Degradation Rate.", f ' [613 int I - SunPower white paper, Feb 2013. See www.sunpower.convfaci_s for details. =standard Test Conditions (1000 W/mz irradiance, AM 1.5, 2S1 C). NREL calibration standard_: SOb1S current LACCS FF and voltage. Al DCvolWe is fully contained within the module. Please read the safety and installadon instructions for details. `Based on average of measi,red pov:er values during production. See mvwsunpower.com/facts for more reference information. For more details, see extended datasheet:,Aww.sunpower.com/datashee[s. w a Document # 515215 Rev B /LTR US 150 �. Solar CME ells 96 Monoc stalline Maxeon® Gen III Front Glass Front High -transmission tempered glass with anti - coating Environmental Outdoor rated Rating IEEE .1547.1 ' Frame Class 1 black anodized (highest AAIMA rating) Weight 45.5 lbs (20.6 kg) Max. InvisilvountIm Recommended' 1.3 in. (33 mm) Module Spacing • Class A Fire Rated when installed with - 280 mm ' [11.02 in] 1107 mm - ' r [43.6 in] 1046 mm ... , [41.2 in] 30 mm II.2 in] 'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 2#1 rank in "PV Module Durability Initiative Public Report," FraAorer CSE, Feb 2013. Five out of the r 1558 mm top eight largest manufacturers were tested. Campeau, Z et al. "SunPower 4lodule Degradation Rate.", f ' [613 int I - SunPower white paper, Feb 2013. See www.sunpower.convfaci_s for details. =standard Test Conditions (1000 W/mz irradiance, AM 1.5, 2S1 C). NREL calibration standard_: SOb1S current LACCS FF and voltage. Al DCvolWe is fully contained within the module. Please read the safety and installadon instructions for details. `Based on average of measi,red pov:er values during production. See mvwsunpower.com/facts for more reference information. For more details, see extended datasheet:,Aww.sunpower.com/datashee[s. w a Document # 515215 Rev B /LTR US Warranties - 25 -year limited power warranty 25 ear limited product warrant UL 1741, including compliance with . applicable requirements of IEEE 1547 and IEEE .1547.1 ' AC module Type 2 Fire Rated UL 2703 Listed when installed with V InvisilvountIm Certifications • Class A Fire Rated when installed with InvisiMouniTM and when distance between " roof surface and bottom of SunPower module frame is <- 3.5" (8.89 cm) Alternating Current (AC) Module designation enables installation in accordance with NEC 690.6 PID Test Potential induced degradation free - 280 mm ' [11.02 in] 1107 mm - ' r [43.6 in] 1046 mm ... , [41.2 in] 30 mm II.2 in] 'Highest of over 3,200 silicon solar panels, Photon Module Survey, Feb. 2014 2#1 rank in "PV Module Durability Initiative Public Report," FraAorer CSE, Feb 2013. Five out of the r 1558 mm top eight largest manufacturers were tested. Campeau, Z et al. "SunPower 4lodule Degradation Rate.", f ' [613 int I - SunPower white paper, Feb 2013. See www.sunpower.convfaci_s for details. =standard Test Conditions (1000 W/mz irradiance, AM 1.5, 2S1 C). NREL calibration standard_: SOb1S current LACCS FF and voltage. Al DCvolWe is fully contained within the module. Please read the safety and installadon instructions for details. `Based on average of measi,red pov:er values during production. See mvwsunpower.com/facts for more reference information. For more details, see extended datasheet:,Aww.sunpower.com/datashee[s. w a Document # 515215 Rev B /LTR US 4 Module* / Mid Clamo and Rail Module* / End Clamp and Rail Mid Clamp Clamp Rail & Rail Splice End Cap Component Material Weight Mid Clamp Black oxide stainless steel AISI 304, 63 V2.2 oz) , End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) , Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6005-TS 830 g/m (9 oz/ft) Ground Lug Assembly 304 stainless (A2-70 bolt; tin-plated copper lug) 1065 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment Curved and =tat Tile Roof Attachment Universal Interface for Other Roof Attachments `Module frame that is compatible with the Invisihlount system required for hardware interoperability, • 0• -MIA• • • Temperature _ -40° C to 90° C (-40° F to 194° F) 2400 Pa uplift Max. load ' 5400 Pa downforce Refer to roof attachment hardware manufacturer's documentation S 2015 SunPower Corporation. All Rights Reserved. SUVPOWER; the SUNPOwER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. sunpower.com Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 8 Warranties 25 -year product warranty S -year finish warranty UL 2703 Listed Certifications Class A fire rating when distance between roof surface and bottom of SunPower module frame is <- 3.5" Refer to roof attachment hardware manufacturer's documentation S 2015 SunPower Corporation. All Rights Reserved. SUVPOWER; the SUNPOwER logo, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. sunpower.com Specifications included in this datasheet are subject to change without notice. Document #509506 Rev 8 INVISIMOUNT RACKING DETAIL SOLAR MODULE END CLA LIV V1J11'IVVIY 1 f�/'11L . CLAMP . *EACH MID CLAMP GROUNDS THE AIL [NVISIMOUNT RAIL t , GreenFasten" GF1 - Product Guide Installation Instructions with Compression Bracket 2 5 Consult an engineer or go to www.ecofastensolar.com for engineering data. err +f��Fy } `� `r "�v' ,�i ',�� � fi t c� 7,Y y i y �t• � ,-�`�� YYw`�� 1y.!•�S �&Vi •��. � 1 ff Y�I ITj � ;�1� F.r.�I y l��s"J 3 4a 4b 4c 1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2.. Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning.when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*, SCL-101-3*, Z-101*, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression ' bracket and the gasketed hole in the flashing and into the rafter. 4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the Basketed hole in the flashing and into the rafter.' 5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. *not pictured. ' 877-859-3947 EcoFasten SolarO All content protected under copyright. All rights reserved. 7/24/2014 ` EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 132 8.181.398 132 8,166,713 132 8,146.299 132 8,209,914 132 8.245.454 132 8,272.174 132 8.225.557 B2 2.1 'o GreenFasten" GF1 - Product Guide Installation Instructions * Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses . Slide flashing up under shingles until leading edge engages nails. Measure remaining distance to adjust „—I— shingle 3. Reinstall flashing with notched area upslope. shingle 2. Remove flashing and cut"V" notch at marks where nail shafts engaged leading edge of flashing the distance desired in Step 1. Notch depth not to exceed 2" length by 1/2" width. // Placement of"V" notch 4. Position notched leading edge underneath nail heads as shown. /, Nails beneath shingle 877-859-3947 EcoFasten SolafO All content protected under copyright. All rights reserved. 7/24/2014 2.2 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 B2 8,153,700 B2 8.181.398 B2 8,166.713 B2 8.146.299 B2 8,209,914 B2 8.245.454 B2 8.272.174 B2 8.225.557 B2 j GreenFasten'" GF1,- Product Guide Cut Sheets: GF1 1!Ilk..: . 011, N' LJ IN, 701 1 ,SECTION A -A . 877-859-3947 EcoFasten Solar" All content protected under copyright. All rights reserved. 7/24/2014 3.1 EcoFasten Solar products are protected by the following U.S. Patents: 8.151,522 B2 8,153,700 B2 8,181.398 B2 8,166,713 B2 8.146.299 B2 8.209,914 B2 8.245.454 B2 8.272.174 B2 8,225.557 132' GreenFasten'" GF1.- Product Guide ' Cut Sheets: GF1= 812 ', �� ���:1 is � � � .. _ .. - - • • iiil{Faa�l,.. � �t ' 1 1'. � _ _ • , f '. � .. . ( ` 8"3 1 /32"± 4X R 8 ,,.— 4 1p t 5 " �'� !ice � .f -.. , ; , -. • 5/64 , 16 Ilk 't ,s1H • .DETAIL A- 4 y SCALE: 2:1 ►: . 77 JJ}} i Finish Options 4 BILK '= Matte Black ' • `'� • 4`' MILL = Mill Finish - - - , - N t t{ ;� � t • 877-859-3947-EcoFasten Solar®AII content protected under copyright. All rights reserved. 7/24/2014 3.2 Ecol'asten Solar products are protected by the following U.S. Patents: 8.151.522 82 8.153,700 82 8.181,398 B2 8,166,713 B2 8.146,299 B2 8,209,914 82_8,245.454 6 8,272.174 132 8,225.557 132 GreenFasten" F1 - Product Guide t _ Cut Sheets: Bracket Options - CP-SQ-Slotted,' . . . 36 ijel�' r 2.00 - R1 � ............. .1.00 , �;t �t�! ;esu t .. � •• • ,. '. 0 0.38".00 S 0.50 0 0.88±.01 X 82° ,t 1 -2.00 , �_f 877-859 3947 'EcoFasten Solar®All content protected under copyright. All rights reserved. 7/24/2014 3.3 EcoFasten Solar products are protected by the following U.S. Patents: 8,151.522 B2 8,153,700 82 8,181.398 B2 8.166,713 1328,146,299 82 8,209,914 82 8,245.454 132 8,272,174 132 8,225.557 B2 y�h GreenFasten': GIF 1• -•Product Guide Cut Sheets: Bracket Options - SCL^101-3 - I � lir{, � i• X .; _ - � ` � J. . -7� k�1►'Ntx1 •46 SERRATIONS. p' .1.11{flit■ � ., _ •+ • - � - '•a ' - ± ,y3 - 1 •4GN 1 I i - - .+ ^ .. . , �« •. .0 -�ti •k — .•✓ al r _ )` - -. . - i � ^� .r .• - R1/16" 1- 7/8" 1 I4" i o 3/4..: 1/16" r ' 1 1 7j j10 ' 2X R.0I �"-d J"► .+— - — -�--- - - —� 60:00° f , f,+.006 3/8 --.002 o ,DETAIL A �,1 t 1• 7/8".X $2 SCALE 3:1 AI �; tk l Z 877-859-3947 EcoFasten Sola&All content protected under copyright. All rights reserved: -7/24/20143.5 r EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 132 8.153.700 132 8.181.396-132 8,166,713 132 8,146.299 132 8,209,914 132 8.245.454 82 8.272.174 132 8.225.557 132 GreenFasten'" GF1 = Product Guide Cut Sheets: Bracket Options - L-102-3" 2X3/8" r i 4 , a .. •_ . • .. r r 46 SERRATIONS t WD'• r ' � r •' rte. • .. t , .� •T _ : .r - Lr) }I ,1 spry � r _ � .� r 'k . a r_ •'r• r , _ •t • �4' I N r �_ = 1' 7/8" ' � R 1 / 16 r J R.005 u, R.01 0 60:00° V ► - ' „+.006 �_ < . F ¢ 40 3/8-.002..1/8 " _, 0.87.5±.010`X..82° DETAILA SCALE 3: 1 h IN l;r ' . .877-859-3947 EcoFasten Solar®All content protected under copyright. All rights reserved. 7/24/2014 3.6 EcoFasten Solar products are protected by the following U.S. Patents: 8.151.522 B2 8,153.700 82 8,181.398 B2 8,166,713 B2 8.146,299 B2 8,209,914 B2 8.245.454 B2 8.272.174 B2 8.225,557 B2 AC Circuit Ampacity Calculator Meter #:I 1007766791•= Customer Name: IMARCH, LESLIE ' c..Location: 4325 CABALLO WAY, CMICQ, CA 95973 i- - Wire Note: AC -1 Description: AC MODULES TO AC DISTRIBUTION PANEL ` Wire Calculation 3.84 kWatts 240 - VAC Split Voltage Configuration TRUE TL Inverter?, T 10 Minimum Wire and Conduit Size based on Voltage Drop and Ampacity. 10 Minimum Ground Size Based on NEC '20.00 A Minimum Ciruit Breaker/Fuse Size �S�Actual Ground Size Based on NEC 20.00 A Ampacity.After Derate 10 Wire Size Based on Ampacity -30 A °/a of Voltage Drop - 10 Wire Size Based on Voltage Drop 30 A . L. Y'k"'YS y 16 A• . -Circuit Ampacity 1 Factor . -i 1 t Phases 0.82 Conditions of Use Derate Factor, ; - 19.51A Minimum.Conductor Ampacity Based on Conditions`of Use 20.00 A Minimum Conductor Ampacity Based on 1.25, Rule. _ Conditions of Use t. 0.82 Derate Total 50 °C Temp'6bf.(ambient*+ Sunlight) 122 °Fx'0.82 Derate s ' 50 °C'Ambient Temp 122 °F r none Sunlight Exposure 1 _ 32 °F 00 °C Temp adder.` 3 or less Number of.Current Carrying Conductors LDerate applied to Temp Coefficient Voltage Drop: Allovvable•Toleran -6 (Solar -Gene -ration 1%6; Di•stribution;3%) 24.0 V Circuit Voltage i - " 16 A Circuit Amps 1 1 24 Resistance 60 ft 'One Way Distance 10 Wire Size 0.9.92 % of Loss t' Conduit Size, (CondVit- Fill Can Not be more than 40%0) Y ' PVC Conduit Type 0.16 : Wire Size Diameter. F 14% Conduit Fill percentage 1 Conduit Size 0.212 Ground Wire Size Diameter ' 0,688 Conduit Internal Diameter 600 V , System Voltage THWN-2 Wire Type' AC Circuit Ampacity Calculator ,Meter #: [ ' 1007766791 Customer Name: MARCH, LESLIE Location: 4325 CABALLQ W_A. Y, CHICO, -A 9,5973 Wire Note: AC-2 I Description: AC DISTRIBUTION PANEL TO MAIN ! Wire Calculation 4 13.76 kWatts. 240 VAC Split Voltage Configuration TRUE TL'Inverter? `. 4 Minimum Wire and Conduit Size based on Voltage Drop and Ampacity' ® Minimum Ground Size Based on NEC 71.67 A Minimum Ciruit Breaker/Fuse Size a 8 Actual Ground'Size.Based on NEC,' ' 71.6_7 A Ampacity After Derate 4 Wire.Size Based on Ampacity 95 A - ° n Voltage age-Drop 0 8829 /a of Voltage Drop • . , 4 Wire Size Based'o p 95 A 0.333 A Circuit Ampacity 1 Factor 1 Phases , ;0.82 Conditions of Use Derate Factor 69.92 A s Minimum Conductor Ampacity Based on Conditions of Use ` '- 71.57 A` Minimum'ConductorAmpacity Based on, 1.25 Rule Conditions of'Use' s• G• 0,:82 Derate Total . 5Q °C Temp Coef (ambient + Sunlight), 122 °F 'T 0-82 r Derate 50 °C Ambient Temp 122 °F ' none Sunlight Exposure " 32 °F r ` 0 °C Temp adder ,. 3 or less Number of Current Carrying.Conductors 1 Derate applied to Temp Coeficient ' Voltage Drop: Allowable Tolerance (Solar Ge-aeration 1%, Distribution 3%) ' 240 V Circuit Voltage 57.333 A Circuit Amps 0 308 Resistance 60 ft One Way Distance 4 Wire Size Q.8829 % of Loss ' Conduit Size`(Concluit Fill Can Not be more than 4Q%) EMT Conduit Type 0.317 Wire Size Diameter 31% Conduit Fill percentage 1 Conduit Size 0.212. Ground Wire Size Diameter r078641 Conduit Internal Diameter 600 V System Voltage THWN-2 Wire Type Butte County Department of Development Services FORM NO PERMIT CENTER : 7 County Center Drive, Oroville, CA 95965 DBI -01 +Mra«a•-�� Main Phone(530) 538-7601 Fax(530) 538-7785 Declaration ®f Installation for Smoky- Alarms and Carbon Monoxide Ala;airs The newly adopted. 2013 California Residential Code requires the installation of Carbon Monoxide Detectors in. dwelling units and in sleeping units within which fuel' -burning; appliances are installed: and: in dwelling. units that.have attached garages._ The: policyfor. Carboni MV onoxide Alarms in Butte Counfystates: "Any permit obtained in which the value of'work. exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unitshall co•nfdrimn to; the following 20:13 California Residential Code requirements for Smoke and Carbon Monoxide Alarms (Section R31:A. & R315)..' 2013 California Residential Code reciuirements for• ,Carbon;Monoxide Alarms, 8313.1 New construction: An approved carbon monoxide alarm shall' be instalfedl i;rr dwelling units and in sleeping units within which fuel -burning appliances are installed; and: inn dwelli=ng units that ha=ve• attached! garages. 8315.1.2 Power supply: For new construction required carbon: monoxide alarms shall receive their primary power from the building wiring where such wiring is servedfrom a. commercial source and shall' be equipped with a battery. back-up. Alarm: wiring shall be, directly connected tD the permanent.building wiring without a disconnecting switch, other than as reauiredifor- over - current pro•te..t'on exceptions: 1. lh dwellingunits, where there is no commercial power supply the carbon. monoxide, alarm: maybe solely battery operated. 2. In existing; dwelling unitsa carbon monoxide alarm is permitted to be; solely battery operated where repairs or alterations do: not result in the removal of wall and ceiling: finishes, er there isno access by means of attic, basement or crawl space. IR315.3.3 Interconnection. Where more than one carbon monoxide alarm is required to be instaaled within the dwelling unit or within a sleeping unit thel alarm shall be interconnected in, a manner that activation of one alarm shall activate all of the alarms in the individ'uaf unit. Exception: 1. Interconnection is not required in existing dwelling units where repairsdo not' resul'tin the. removal of wall and ceiling finishes there is no access by means of, attic, basement or crawl space, and no previous rne',hod for interconnection existed. ti R315.2 Where required in existing dwellings: Where a permit is required; for alterations, repairs or additions exceeding one thousand dollars ($1,000), existing dwellingsor steeping units that have attached, garages or fuel -burning appliances shall be provided with. a, carbon . . monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained:. R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for'sale or sell any carbon monoxide device in the State of California unless the -device and instructions have been approved and listed by the State Fire Marshal. Nae I of 2 Carbon monoxide alarms required by Sections R3.15A and R315.2 shall be installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2. On every level of a dwelling: unit including basements. R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2013 CRC, Sections 314 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be. retrofitted with smoke alarms and those that have attached garages or fuel -burning appliances shalt have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARA71ON OF INS7ALLA730N UNDER THE PENALTY OF PERJURY As Owner/Contractor, llwe� affirm and, declare under the penalty of perjury, under laws of the State of California, by our signatures below as Owner/Contractor. that Uwe, will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementionedbuilding code and maintaining such installation. Smoke Alarms will also be installed prior to final inspection as per the 2010 CRC. Smoke and Carbon Monoxide alarms are now installed in the following locations EAC, TED Q1r0m i C-AA,90N S yN h ni t w lacy Owner's name (print): Lez> Owner's signature: /i Date: l Contractor's name (print): E, Zn c , CSLB License:Z5 CJ 3 35 Contractor's signature: 7. Date: l° Project Address: 5 CA --5 A LL b WRY Permit #: � Page 2 of 2