Loading...
HomeMy WebLinkAbout007-340-028BUTTE COUNTY BUTTE DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot euarantee inspections on the date reauested Office: 530.538.7601 Fax:530.538.7785 w�vw.ButteCountv.net/dds Permit No: B17-1736 Issued: 8/7/2017 APN: 007-340-028 Address: 3121 CORONADO RD, CMCO Owner: HALLBAUER WARREN K & MARY R Permit Type: SOLAR ROOF -RES Description: Install 3.6KW roof mount to existing meter AREA 4 Flood Zone: None SRA Area: No Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Insvection Tyve IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Sign d Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin /Under inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed ShearwallB.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 Manometer Test 605 Do Not Install Siding/Stucco or Rooring Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Piping House ..403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802,( Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Inspection Tyve IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fen cing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin /Under inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirtin Ste s/Landin s 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: r Length x Width: Insignia: Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final **PROJECT FINAL 16A 1a2, -rroject rmai is a t-ernncate of ticcupancy for (Keswennai vinyl PERMITS BECOME FULL AND VOID I YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A I YEAR RENEWAL 311 DAYS PRIOR TO EXPIRATION PROJECT OWNER: HALLBAUER, MARY 3121 CORONADO RD. CHICO, CA 95973 APN:007.340.028 PH#:530.592.8527 EMAIL:jtazzmania2@sbcglobal.net CONTRACTOR: ALTERNATIVE ENERGY SYSTEMS INC. 13620 HIGHWAY 99 CHICO, CA 95973 CSLB: 853351 C-10, C-46 BUILDING JURISDICTION: BUTTE COUNTY DEPT. OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 OFFICE#: (530) 538-7601 FAX#: (530) 538-2140 MON-FRI 8AM-3PM INSPECTION LINE: (530) 538-4365 REQUESTS PHONED IN BY 2PM WILL BE INSPECTED THE NEXT BUSINESS DAY INSTALL PHOTOVOLTAIC SOLAR SYSTEM ON A TRUSS ROOF, MOUNTED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES SPECIFICALLY REFERENCING THE 2016 CALIFORNIA ELECTRICAL CODE/ 2014 NEC USING THE FOLLOWING SPECIFIC EQUIPMENT: 1. MODULES: SUNPOWER (10) SPR -X22 -360 -C -AC 3.60kW SYSTEM 183 SQFT COVERED 2. INVERTER(S): SUNPOWER (10) MODULE INTEGRATED 320W SITE MAP j • 3E # CONTENT PV -1.0 p C, m s HALLBAUER, MARY ARRAY LAYOUT PV -4.0 ELECTRICAL DIAGRAM m LABEL DIAGRAM fa GENERAL NOTES o'o_ MODULE SPECS 3121 CORONADO RD. I� p °moo A o CHICO, CA 95973 �rA APN:007.340.028 PH#:530.592.8527 j • 3E # CONTENT PV -1.0 SCOPE PV -2.0 SITE PLAN PV -3.0 ARRAY LAYOUT PV -4.0 ELECTRICAL DIAGRAM PV -4.1 LABEL DIAGRAM PV -5.0 GENERAL NOTES ATTACHMENT MODULE SPECS INVERTER SPECS RACKING SPECS WIRE CALCS tj ,. Ln �. 250:89'"',:- Energy For Life 9' � 58M,=MM U ®a0 Alternative Energy Systems Inc. 13620 HWY 99 CHICO, CA 95973 PHONE#: (530) 345-6980 z FAX#: (530) 892-2360 51 design@solarenergyforlife.com �N� (E) RESIDENCE _- "' jr (E) PGE METER & _' `.: - y (E) SERVICE PANEL M (EDISTRIBHTION PANEL & _(E) INVERTER L_OCATIO.N'"" (P) MONITORING &� DISTRIBUTION- PAN EL;LOCATION sir rr )SHOP (E)'COMPOSITION -ROOF 7. W/ WOOD TRUSSES .r0 . Sl— SOLAR•ARRAY - -, PERMIT B09 0074 A SITE P(AN n o ' ; W HALLBAUER, MARY 13620 HWY 99 Ener9YForLlfe CHICO, CA 95973 m < 's N _ ° o 3121 CORONADO RD. CHICO, CA 95973 V4 PHONE#: (530) 345-6980 p 0 g FAX#: (530) 892-2360 Z O D o APN:007.340.028 PH#:530.592.8527 Alternative Energy Systems Inc. design@solarenergyforlife.com +. _ , • t�, • ' ._ � • : ` � ; r � •� " ` • _ ' ° '. ARRAY LAYOUTr �. HALLEAUER MARY. Eneryy.ForLife -CHICOCA w HWY 99 s •_ 95973 -3o - :s :. - r• 3121 CORONADO RD. �13620 ro PHONE#: (530) 345-080 45-680� . o o CHICO_CA 95973o ' FAX#: (530) 892-2360 ' . • < '-, ti PH#:530.592.8527 • • Alternative Energy Systems Inc.APN:007.340.028 design@ sola renergyforlife Com r. A In s - n- n ry n ., ,� , ,�, a o El e.:>. 61-01- 1_0„ATTACHMENTS ATTACHMENTSMAX 6' ON CENTER- .- - - +. _ , • t�, • ' ._ � • : ` � ; r � •� " ` • _ ' ° '. ARRAY LAYOUTr �. HALLEAUER MARY. Eneryy.ForLife -CHICOCA w HWY 99 s •_ 95973 -3o o 3121 CORONADO RD. �13620 ro PHONE#: (530) 345-080 45-680� . o o CHICO_CA 95973o ' FAX#: (530) 892-2360 ' . • < '-, ti PH#:530.592.8527 • • Alternative Energy Systems Inc.APN:007.340.028 design@ sola renergyforlife Com r. A AC-1 - - t SERVICE VOLTAGE ON ROOF w/ 1 20 = - 1- 2=2 OV � (2) TRANSITION CABLE AC-1 120V=N-L2-L3=NAV WIRE RUN: S' (1) #30 - 2 WIRE NM CABLE CU. AC-(E) NAV=N-L3-Ll=NAV — — — — — — — — — — — — - IMP: 20A WIRE RUN: 40' IMAX: 36A , I l IMAX: 20A I � I l , METER l (10) PV MODULES/INVERTERS I JUNCTION SUNPOWER:SPR-X22-360-C-AC I BOX 240V/1P/1.33A ( / 20A 1P 240V 100A 20A 1P 1P 240V — -- — — — — _ 1 lEl lE) (E) (E) 240V l I I SQB Iiv 15A(24) PV MODULES I JUNCTION = INVERTER-"A" 1PSNAP: M NT-175U1 BOX DC-DISC 3.8KW GRID TIED INVERTER 240V600V I SQUAR D 16A/1P/240V 60A I I HEAVY DUTY SMA: SB3.8-15P-US-40 1P - — — — — — — — - 30A/ 1P/ 240V - W/INTEGRATED DC DISC. _ (N )AC DISTRIBUTION PANEL SN#: 125A/ 1P/ 240V (EXISTING PV SYSTEM) (E) 1A 5A/1P/ 40VNEL - SCIR: 10,000 METER#:1009691438 (E) AC-MONITORING • (1) 1/2" EMT w/ - • #14THWN-2 CU. & TO (E) SUB #14 TH - WIRE RUN: 10'2 CU. GRD. CAT-5 SUNPOWER - _ • 'MONITORING 1 I � , ROUTER ELECTRICAL DIAGRAM n m 0 D° S HALLBAUER MARY 13620 HWY 99 ° m < = o m 3121 CORONADO RD. Energy For Life CHICO, CA 95973 a m D p m ° K p fq PHONE#: (530) 345-6980 Z 3 s D p g CHICO, CA 95973 ®®o' FAX#: (530) 892 2360 n °� APN:007.340.028 PH#:530.592.8527 D Alternative Energy Systems Inc. design@solarenergyforlife.com � , . ^c,v^RRAY WARNING UTILITY INTERACTIVE POWER FLOWING THROUGH THIS PANEL KW SOLAR GENERATOR AC OPERATING VOLTAGE: --/_VAC/_PHASE WARNING .4" PHOTOVOLTAIC SYSTEM EQUIPPED DUAL POWER SUPPLY WITH RAPID SHUTDOWN 71 PHOTOVOLTAIC SYSTEM Per NEC 690.54, Interactive Point of Interc6nnection installed at all Electrical Per NEC 705.10, Point of Connection, Distribution Panel covers that provide a path Located On Main Service Panel. from PV t6 Utility. AC PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATION Per NEC 690.14, Disconnection means at the single AC Disconnect or Main Breaker. SOLAR BREAKER DO NOT RELOCATE Solar breaker label @ any breaker passing Bi -Directional Po''wer, Energy For Life CHICO, CA 95973. 3121 CORONADO RD. 0 PHONE#: (530) 345-6980 CHICO, CA 95973 moo FAX#- (530) 892-2360 OZ Alternative Energy -Systems Inc. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2014 NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND FIRE DISTRICT REGULATIONS. 1. ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL TESTING LABORATORY AN INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. 2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL UTILITY BEFORE COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM. 3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR MOUNTED TRANSITION BOXES, COMBINER BOXES, AND SWITCHES. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ART.250,690. 5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES. 6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER THEY ARE EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH AN OPAQUE COVERING. 7. PHOTOVOLTAIC SYSTEM SHALL BACKFEED THE DISTRIBUTION SYSTEM ON SITE PER THE REQUIREMENTS OF NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE IDENTIFIED AS SUCH AND SHALL BE SECURED IN PLACE BY ADDITIONAL FASTENER PER THE REQUIREMENTS OF NEC 408.16(F). 8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL ROOF WORK. 9. ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75° C MINIMUM. 10. NEC ART. 690.14. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 11. NEC ART. 690.53. -SEE SHEET RE -4.1 FOR LABEL DIAGRAM 12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! -ELECTRICAL SHOCK HAZARD - DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND LOAD SIZE MAY BE ENERGIZED IN THE OPEN POSITION". 13. GROUNDING OF ALL DWELLINS SHALL BE CONFIRMED. 14. CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED PHOTOVOLTAIC ARRAYS LOCATED ON DWELLINGS PER 2014 NEC ART.690.17. 15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT SYSTEMS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER 2014 NEC ART.210.41) 16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION AND IS LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY REGULATIONS. 17. PHOTOVOLTAIC SOURCE CURRENTS MUST BERATED AT BOTH 125% OF THE PARALLEL MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL OF 156% OF THE LOAD. 18. PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT MEANS IF THEY ARE NOT IN THE SAME LOCATION PER 2014 NEC ART.690.56. 19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP RESULTING FROM SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION 1613A AND ASCE STANDARD 7-05, CHAPTER 13. 20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION OF ALL RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS AND OTHER ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL PHOTOVOLTAIC SYSTEMS. 21. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, THE CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT PV SYSTEM IS INSTALLED AS SPECIFIED IN THESE DRAWINGS. 22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF THE EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE DRAWING IS TO INDICATE SIZE, CAPACITY, APPROXIMATE LOCATION AND GENERAL RELATIONSHIP, BUT NOT EXACT DETAIL OR PHYSICAL PLACEMENT. 23. FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM LOCAL UTILITY. 24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY LOCATED FROM EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH LOCATION. AS PER 2014 NEC 690.5(H) AND IN ACCORDANCE WITH 2014 NEC 705.10. 25. A NON FOLDING LADDER WILL BE IN PLACE AND SECURED TO THE ROOF TO PROVIDE ACCESS FOR ALL INSPECTIONS. ALL BOXES WILL BE OPENED UPON REQUEST. 26. SMOKE AND CARBON MONOXIDE ALARMS WILL BE INSTALLED IN ACCORDANCE WITH CRC R314 R315 13620 HWY 99 o s HALLBAUER MARY Z = o Energy For Life CHICO, CA 95973 <' C Z r 3121 CORONADO RD. p o o®� PHONE#: (530) 345-6980 0 0 p g CHICO, CA 95973 1� APN:007.340.028 PH#:530.592.8527 Alternative Energy Systems Inc. FAX#: (530) 892-2360 design@solarenergyforlife.com lune 22,-2017 �. ✓µ f To Whom it May Concern, I. In order to meet future advanced grid requirements, SunPower® is transitioning from Type C AC modules to Type D AC modules. The purpose of this letter is to demonstrate the mechanical and electrical equivalencypf Type C AC modules and Type D AC modules. Type D AC modules are drop-in replacements for TypeYC AC modules and are available at the same DC and AC power levels. Type D AC modules have the same form, fit, and function as Type C AC modules. .The AC electrical output specifications of Type C AC modules and Type D AC.modules are equivalent, ensuring interchangeability -. for AC conductors, overcurrent protection devices, and grounding. -" �- SunPower Type D AC modules are certified per UL 1741 SA to the following SRDs: IEEE'1547, IEEE 1547a, and CPUC Rule ~21 Phase 1. These additional certifications and functionality enable Type D AC modules to meet California CPUC Rule 21' Phase 1 smart inverter requirements. The following table lists the Type C AC.module models and their. respective Type D ;equivalents, as of the date of this letter: E19 -320 -C -AC M. E19 -320 -D -AC E20 -327 -C -AC E20 -327 -D -AC= • '' X21-335-BLK-C-AC = :. X21-335-BLK-0-AC ' X21 -335 -C -AG X21 -335 -D -AC X21 -345 -C -AC • X21 -345 -D -AC X22 -360 -C -AC X22 -360 -D -.ACs. y M Where Type D AC modules are substituted in the field for Type C AC modules, no changes to the physical layout,.structuraI loading,'electrical design, or interconnection are 'required. Should you have any questions or concerns, please confact SunPower Technical Support at 1 800'786.7693.` 'Best Regards,' Matt Mayberry- t r Director, Residential Product Management 4, 1t Q` tQe-n +� 1... w•.�. '..e� '�S'� C'.,' h•'Y" -�..-. �. ,yam, Imm L% Design -Driven Advantages. #1 module aesthetics and efficiency' ' Unmatched module reliabilityz No electrolytic capacitors 25 -year Combined Power and Product Warranty Maximize Value for Roof Size system for roof, not string inverter �} Optimize performance of each module F Expand Deployment Options Complex roofs and partial shading Small systems System expandability -i Simplify & Speed Installation • ! Factory -integrated microinverter Robust, double -locking AC connectors Design flexibility offsite and onsite No DC string sizing process Fewer installation steps than competing systems Intuitive cornmissioning iComponent of Complete System Built for use with SunPower° InvisiMount"" ' and the SunPower Monitoring System f > Superior system reliability and aesthetics t 1 r l 1 X SERIES Optimize System and Installation -Efficiency SunPowert AC Modules, which include a factory -integrated SunPower microinverter, provide a revolutionary combination of high efficiency, high reliability, and module -level DC -to -AC power conversion. Designed specifically for use with SunPower InvisiMount' and the SunPower Monitoring System, SunPower AC Modules enable rapid installation, best -in -class system aesthetics, and intuitive visibility into system performance. All this comes with the best Combined Power and Product Warranty. >� r sunpower.com 'Highest of over 3,200 silicon solar panels, Photon Module Survey. Feb. 2014 2#1 rank in "PV tvlodule Durabiliy Initiative Public Report," Fraunhofer CSE, Feb 2013. Fite out of the top eignt larges; mantAc:urers were tested. Campeau, 2. et al "SunPower Module Degradation Rate.' SunPower white paper, Feb 2013. See Am sunpower.com/rads for details. l 3Standard Test Conditions (1000 wrm, irradiance, AM 1.5.25' Q. NREL calibration standard: SOMS t current, LACCS FF and voltage. All DC voltage is fully concerned within :he module. 19ased on average of measured power values during production. See �swwsunpowei xom/facts fort rnore re`ei ence information. For more derails, see extended datasheee w+,wr.sunpower.com/daiashee-s. Output @ 240 V (min./nom./max.) Outpu[ @ 208 V (min./nom./max.) SPR -X22 -360 -C -AC Nominal Power3(Pnom) 360 W Power Tolerance +5/-0% Avg. Panel Ef lciency= 22.2% Temp. Coef. (Power) -0.30%/0 C Shade Tolerance Three bypass diodes Integrated module -level maximum power point tracking 'Highest of over 3,200 silicon solar panels, Photon Module Survey. Feb. 2014 2#1 rank in "PV tvlodule Durabiliy Initiative Public Report," Fraunhofer CSE, Feb 2013. Fite out of the top eignt larges; mantAc:urers were tested. Campeau, 2. et al "SunPower Module Degradation Rate.' SunPower white paper, Feb 2013. See Am sunpower.com/rads for details. l 3Standard Test Conditions (1000 wrm, irradiance, AM 1.5.25' Q. NREL calibration standard: SOMS t current, LACCS FF and voltage. All DC voltage is fully concerned within :he module. 19ased on average of measured power values during production. See �swwsunpowei xom/facts fort rnore re`ei ence information. For more derails, see extended datasheee w+,wr.sunpower.com/daiashee-s. Output @ 240 V (min./nom./max.) Outpu[ @ 208 V (min./nom./max.) 211/240/264 V 183/208/229 V Operating Frequency (min./nom./max.) 59.3/60.0/60.5 Hz Output Power Factor (min.) 0.99 - .AC Max. Continuous Output Curren[ @ 240 V AC Max. Continuous Output Current @ 208 V 1.33 A 1.54. A AC IViax. Cont. Output Power- 320 W DC/AC CEC Conversion Efficiency 96.0% Max. Units Per 20 A Branch Circuit @ 240 V Max. Units Per 20 A Branch Circuit @ 208 V. 12 (single phase) .. 10 ((wo pole) - 'Highest of over 3,200 silicon solar panels, Photon Module Survey. Feb. 2014 2#1 rank in "PV tvlodule Durabiliy Initiative Public Report," Fraunhofer CSE, Feb 2013. Fite out of the top eignt larges; mantAc:urers were tested. Campeau, 2. et al "SunPower Module Degradation Rate.' SunPower white paper, Feb 2013. See Am sunpower.com/rads for details. l 3Standard Test Conditions (1000 wrm, irradiance, AM 1.5.25' Q. NREL calibration standard: SOMS t current, LACCS FF and voltage. All DC voltage is fully concerned within :he module. 19ased on average of measured power values during production. See �swwsunpowei xom/facts fort rnore re`ei ence information. For more derails, see extended datasheee w+,wr.sunpower.com/daiashee-s. Operating Temp. -40° F co =185° F (-40° C to -85° Q Max. Ambient Temp. 122° F (500 Q Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back Environmental Snow: 125 psf, 6000 Pa, 61'1 kg/m2 frorii Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 - Frame M/S) 'Highest of over 3,200 silicon solar panels, Photon Module Survey. Feb. 2014 2#1 rank in "PV tvlodule Durabiliy Initiative Public Report," Fraunhofer CSE, Feb 2013. Fite out of the top eignt larges; mantAc:urers were tested. Campeau, 2. et al "SunPower Module Degradation Rate.' SunPower white paper, Feb 2013. See Am sunpower.com/rads for details. l 3Standard Test Conditions (1000 wrm, irradiance, AM 1.5.25' Q. NREL calibration standard: SOMS t current, LACCS FF and voltage. All DC voltage is fully concerned within :he module. 19ased on average of measured power values during production. See �swwsunpowei xom/facts fort rnore re`ei ence information. For more derails, see extended datasheee w+,wr.sunpower.com/daiashee-s. Warranties 25 -year limited p6wer warranty •-25-year limited product warranty - UL 1741, including compliance with ; applicable requirements of IEEE 1547 and IEEE 1547.1 FCC and ICES -003 Class B AC module Type 2 Fire Rated ' UL 2703 InvisiMounti' Listing maintained, Certifications when installed with this AC Module Class A Fire Rated when installed with InvisiMount'"' and when distance between roof surface and bottom of SunPower module frame is s 3.5" (8.89 cm) ` • Alternating CUrrent (AC) Module designation enables installation in accordance with NEC 690.6 PID Tes[ Potential -induced degradation free , t - .1046 mm -130mm " [41.2 in] c- - ' (1.2 in) 1558 mm [61.3 in) Please read the safey and installation instructions for details. Document = 516046 Rev C /LTR US Solar Cells' 96 IvIonocryscalline IMaxeon® Gen III Hieh-transmission tempered glass with anti - Front Glass reflective coating Environmental Outdoor rated.. Rating _ Frame Class 1 black anodized (highest AAMA rating) Weight 455 lbs (20.6 kg) Flax. Recommended 1.3 in. (33 mm) ' Module Spacing ' Warranties 25 -year limited p6wer warranty •-25-year limited product warranty - UL 1741, including compliance with ; applicable requirements of IEEE 1547 and IEEE 1547.1 FCC and ICES -003 Class B AC module Type 2 Fire Rated ' UL 2703 InvisiMounti' Listing maintained, Certifications when installed with this AC Module Class A Fire Rated when installed with InvisiMount'"' and when distance between roof surface and bottom of SunPower module frame is s 3.5" (8.89 cm) ` • Alternating CUrrent (AC) Module designation enables installation in accordance with NEC 690.6 PID Tes[ Potential -induced degradation free , t - .1046 mm -130mm " [41.2 in] c- - ' (1.2 in) 1558 mm [61.3 in) Please read the safey and installation instructions for details. Document = 516046 Rev C /LTR US • 3 Module / Mid Clamp and Rail , Module* / End Clamp and Rail End Cia np pail u Rail Splice cnd Cap l ilk • •••i -• • � ., Component Material Weight klid Clamp Black oxide stainless steel AISI 304 53 g (2.2 oz) End Clamp Black anod'zed aluminum alloy 6063-T6 110 g (3.30 oz) Rai Black anod!zed aluminum cloy 6005-T6 330 g/m (9 oz: ft) Rail Solice Aluminum alloy 5005-T5 330 g:m (9 oz/ft) Ground Lug Assembly106.5 304 stainless (A2-70 boil, un -placed copper lug) -!m (3.75 oz) End Cap Black aceta; (RCAd) copolymer 10.4 g (037 oz) ilk • •••i -• • � ., Alarranties 25 -year product warranty Ccmoos'(ion Shingle P.afier Attachm.=_nt Application Compos,don Sh'ngle Roof Decking Attachment UL 2703 Listed Curved and Flat Tile Roef Attachment Class A fire rating when distance between Universa; Interface for Cmer Roof Attachments Temperature -40° C to 90° C (-40° F to 194° F) Max. Load 2400 Pa upiif, 5-^00 Pa downforce Refer to roof at:achme,�t hardware manufacturer's documenta,.on 1 *"dodule frame that Is compatible with the Invisitvlount system required for hardware interoperability. 3 20;5 Son Power'Corpotition. A" Rights Reserved. SUNPOOrR, the SUNPOwERlogo, and INV1SIMOUNTare trademarks or registered trademarks of SunPower Corpor.tuon. A'I ether trademarks ai e [hie property o their r^spective owners. sunpCwe!com Specifications included in this datasheet are subject to change without notice. Document a509506 Rev 8 Alarranties 25 -year product warranty 5 -year finish warrant`j UL 2703 Listed Certifications Class A fire rating when distance between roof surface and bottom of SunPower module frame is <— 3.5" Refer to roof at:achme,�t hardware manufacturer's documenta,.on 1 *"dodule frame that Is compatible with the Invisitvlount system required for hardware interoperability. 3 20;5 Son Power'Corpotition. A" Rights Reserved. SUNPOOrR, the SUNPOwERlogo, and INV1SIMOUNTare trademarks or registered trademarks of SunPower Corpor.tuon. A'I ether trademarks ai e [hie property o their r^spective owners. sunpCwe!com Specifications included in this datasheet are subject to change without notice. Document a509506 Rev 8 INVISIMOUNT RACKING DETAIL 11Y V1J11'IVVIV I fR/11L > CLAMP * EACH MID CLAMP GROUNDS THE AIL r K lkl: GreenFasten'" GF1 - Product Guide 2 5 Consult an engineer or go to www.ecofastensolar.com t} for engineering data. Installation Instructions with. Compression Bracket sv'�'1�i4` la Gyly ,r i '4' �'�t,r,�,y, y.''•` ,"fir: rr. ^.y ��� Y sr• r �� t `'lq,.ri �,� 4., !4 � ♦,. � a' n.r" 4 tr uta+„ rr.`d'iy � f � h ,�' s'"t`4 • ////�j�'3V�r :,•r L'Yj � s c•� i- � N `�`"?r , . �j � ``"' , ' Xr1'�,f } �..r•x d % � � A f?.>E' ,t, r.�r rS �c5� rte.. ��,. � ����.� ; � '.� � •�2 3 4a 4b 4c 1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1 /4" diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar - recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*, SCL-101-3*, Z-101 *, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the gasketed hole in the flashing and into the rafter. 4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. 5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an, impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. not pictured. 1 =t" '''13 877-859-3947 EcoFasten SolarO All content protected under copyright. All rights reserved. 7/24/2014 - 2.1 Fasten Solar products are protected by the tollowin4 U.S. Patents: 8.151,522 B2 8,153,700 B2 8.181,398 B2 8,166.713 B2 8.146.299 B2 8.209,914 B2 8,245.454 B2 8,272.174 B2 8,225.557 B2 . I 6 { 2 5 Consult an engineer or go to www.ecofastensolar.com t} for engineering data. Installation Instructions with. Compression Bracket sv'�'1�i4` la Gyly ,r i '4' �'�t,r,�,y, y.''•` ,"fir: rr. ^.y ��� Y sr• r �� t `'lq,.ri �,� 4., !4 � ♦,. � a' n.r" 4 tr uta+„ rr.`d'iy � f � h ,�' s'"t`4 • ////�j�'3V�r :,•r L'Yj � s c•� i- � N `�`"?r , . �j � ``"' , ' Xr1'�,f } �..r•x d % � � A f?.>E' ,t, r.�r rS �c5� rte.. ��,. � ����.� ; � '.� � •�2 3 4a 4b 4c 1. Locate the rafters and snap horizontal and vertical lines to mark the installation position for each GreenFasten flashing. 2. Drill a pilot hole (1 /4" diameter) for the lag bolt. Backfill with sealant. EcoFasten Solar - recommends an EPDM mastic. 3. Insert the flashing so the top part is under the next row of shingles and pushed far enough up slope to prevent water infiltration through vertical joint in shingles. The leading edge of flashing must butt against upper row of nails to prevent turning when tourqued. See page 2.2 for vertical adjustment when leading edge of flashing hits nails in upper shingle courses. 4. Line up pilot hole with GreenFasten flashing hole. 4a Insert the lag bolt through the EPDM washer, the top compression component bracket (L- 102-3, L-102-6*, SCL-101-3*, Z-101 *, Conduit Mount Bracket*) and the gasketed hole in the flashing and into the rafter. 4b Insert the lag bolt through the EPDM washer, the Comp Mount Slide compression bracket and the gasketed hole in the flashing and into the rafter. 4c Insert the lag bolt through the SS washer, the third -party bracket, the EPDM bonded washer, the CP -SQ -Slotted compression bracket and the gasketed hole in the flashing and into the rafter. 5. Torque: The range is between 100-140 torque inch -pounds depending on the type of wood and time of year. The visual indicator for proper torque is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an, impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet to finish the install. not pictured. 1 =t" '''13 877-859-3947 EcoFasten SolarO All content protected under copyright. All rights reserved. 7/24/2014 - 2.1 Fasten Solar products are protected by the tollowin4 U.S. Patents: 8.151,522 B2 8,153,700 B2 8.181,398 B2 8,166.713 B2 8.146.299 B2 8.209,914 B2 8,245.454 B2 8,272.174 B2 8,225.557 B2 GreenFasten" GF1 - Product Guide Installation Instructions * Use for vertical adjustment when leading edge of flashing hits nails in upper shingle courses . Slide flashing up under shingles until leading edge engages nails. Measure remaining distance to adjust — -- shingle 3. Reinstall flashing with notched area upslope. shingle 2. Remove flashing and cut "V" notch at marks where nail shafts engaged leading edge of flashing the distance desired in Step 1. Notch depth not to exceed 2" length by 1/2" width. V" notch 4. Position notched leading edge underneath nail heads as shown. Nails beneath shingle 877-859-3947 EcoFasten Solar' All content protected under copyright. All rights reserved. 7/24/2014 I EcoFasten Solar products are protected by the follownq U.S Patents 8.151.522 82 8,153.700 B2 8.181.398 82 8.166.713 B2 8.146.299 82 8.209.914 B2 8.245.454 B2 8.272.174 B2 8.225,557 B2 2.2 877-859-3947 EcoFasten Solar'DAll content protected under copyright. All rights reserved. 7/24/2014 . ' 3;1 EcoFasten Solar products are protected by the following U.S. Patents: 8,151.522 B2 8,153,700 B2 8.181.398 B2 8,166.713 B2 8,146.299 B2 8,209.914 B2 8,245,454 B2 8,272.174 B2 8,225.557 B2 r .-e.a.�i. .... � .�1. 'ti' ...yip w-M�• �. Y. .. �.. - �.t� - ' �, . - ..� S -- Y . ... � - r i t -y ;, r { • £ ' .. SECTION -A f ,_ _A 877-859-3947 EcoFasten Solar'DAll content protected under copyright. All rights reserved. 7/24/2014 . ' 3;1 EcoFasten Solar products are protected by the following U.S. Patents: 8,151.522 B2 8,153,700 B2 8.181.398 B2 8,166.713 B2 8,146.299 B2 8,209.914 B2 8,245,454 B2 8,272.174 B2 8,225.557 B2 GreenFasten'" GF1 — Product Guide R . Cut Sheets: GF1-y812 4X R- 8— 1 /32''± �8 04 5/64 5 w z 16 ' t LL • DETAIL A f 4 .., c y SCALE: 2:1 Finish Option's BLK = Matte Black r , • • _ MILL =Mill Finish 877-859-3947 EcoFasten SolarO All content protected under copyright. All rights reserved. 7/24/2014 i > 3.2 EcoFasten Solar products are protected by the following U.S. Patents: 8.151,522 B2 8,153,700 B2 8,181.398 B2 8,166.713 B2 8,146.299 B2 8.209.914 B2 8,245.454 B2 8.272.174 82 8,225.557 B2 -. rr , GreenFasten"• GF1 — Product Guide_ - Cut Sheets: Bracket Options' -•CP -SQ -Slotted - 1.50 - .06._1■■ 50 f z. •1. .; W ., ' [. • - • r. a _. _ • L . N 2.00 1.00 1.00 0 0.38±.00 S 0.50 ; ,, • .' �, - , ` �'/ 00. 88±.Ol X 820 L 2.00 --}— !'Y a •l 877-859-3947 EcoFast6n Solar' All content protected under copyright. All rights reserved. -7/24-/2014 a 3.3 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 B2 8,181.398 132 8.166.713 132 8.146.299 132 8.209,914 132 8.245.454 132 8,272,174 B2 8,225.557 62; IVF f- - 1.50 - .06._1■■ 50 f z. •1. .; W ., ' [. • - • r. a _. _ • L . N 2.00 1.00 1.00 0 0.38±.00 S 0.50 ; ,, • .' �, - , ` �'/ 00. 88±.Ol X 820 L 2.00 --}— !'Y a •l 877-859-3947 EcoFast6n Solar' All content protected under copyright. All rights reserved. -7/24-/2014 a 3.3 EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 132 8,153,700 B2 8,181.398 132 8.166.713 132 8.146.299 132 8.209,914 132 8.245.454 132 8,272,174 B2 8,225.557 62; GreenFasten"GF1 " Product Guide Cut Sheets: Bracket Options - SCL-101=3" r . r 3/8" 46 SERRATIONS , ZY5 \ 1 7/8" T Rl/16 '1 /4" oo L . 3/4„ 1/16,: - R.005 R.010 2X R.01 . y , 60.000 • .:3 8..+.006 / -.002 T/8" X 82° . DETAIL A SCALE 3:1 r ," 64 877-859`3947 EcoFasten Solar')All content protected under copyright. -All rights reserved. 7/24/2014 0 3.5 EcoFasten Solar products are protected N'the Pollowinq U.S. Patents: 8.151,522 B2 8.153.700 B2 8.181.398 B2 8,166,713 B2 8,146,299 B2 8.209,914 B2 8,245.454 B2 8.272,174 B2 8,225.557 B2 GreenFasten" GF1 Product Guide Ir 'Cut Sheets: Bracket Options - L-102-3" 2X 3/8" 46 SERRATIONS ' y `O { CV Lo" . ... x ' 1'7/8"' CV 15/ 1,6" '. RIP 6' - /, 604 — _ -- - 1x%16" .� ;o R .005 R-.010 s2XR01 -6tZ�,A 006 y 03/8„+:002 ? :1/8" x.875+_.010 X 82° R DETAIL A SCALE 3: 1 ' 'furs • I • • • A _ � - ` • .. ,•' r. -t r }.- . (r • ; . •'v.��. r ', A ' i 3 877-859-3947 EcoFasten Sola&All content protected under copyright. All rights reserved. 7/24/2014 3.6 EcoFasten Solar products are protected by the Following U.S. Patents: 8,151,522 B2 8.153,700 132 8,181,398 132 8,166,713 132 8.146,299 B2 8.209.914 B2 8.245.454 132 8.272.174 132 8,225.557 132 " AC Circuit Ampacity Calculator Meter #: 1305651438' Customer Name: HALLBAUER, MARY _. Location: 3121 CORONADO RD.,'Chico, CA 95973 - Wire Note: AC -1 Description: INVERTER TO AC DISTRIBUTION PANEL ` - _ - - Wire Calculation �3.84� kWatts 240 JVAC _ Split Voltage Configuration TRUE ITL Inverter? 1.0 Minimum Wire and Conduit Size based on Voltage Drop and Ampacity 10` Minimum Ground Size Based on NEC, 20.00 A Minimum Ciruit Breaker/Fuse Size 10 Actual Ground Size Based on NEC 20.00 A Ampacity After Derate 10 1 Wire Size Based on Ampacity - 30 A 0.6613 % of Voltage Drop 10 Wire Size Based on Voltage Drop - -,3.0 A 16 A Circuit Ampacity F 17-1 Factor 1' Phases '0.96 Conditions of Use Derate Factor 16.67 A Minimum Conductor Ampacity Based on Conditions of Use 20.00 A Minimum Conductor Ampacity Based on 1.25 Rule ,p6ditions of Use 0.96 berate Total 35 `C Temp Coef (ambient + Sunlight) -*F— =0:96 Derate 35 'C Ambient Temp °F none Sunlight Exposure 13*F 0 °C Temp adder 3 or less Number of Current Carrying Conductors 1 _ ` Derate applied to Temp Coeficient Voltage, All Tolerance (Solar -Generation 1%; Distribution"3%).." k ># 240 V Circuit Voltage ft ` 16, A Circuit Amps Resistance X40 'One Way Distance X10,• • Wire Size 1:0% of Loss Conduit 5ize.(Con_doit FiL Can'Not,be'morg than40%)` . � a "-�,7-7-T 77 None Conduit Type 'o..16.- Wire Size Diameter #N/A/A Conduit Fill percentage 1 Conduit Size 0 16' • Ground Wire Size Diameter #ly/A; Conduit Internal Diameter 600 V System Voltage THWN-2 Wire Type