HomeMy WebLinkAbout009-072-020Residential Fire.:: Sprinkler System Component List`: 4 _ WATER Z'E S Ir C3uAGE. 5 _ 2 PULE FLOW SW I -.r. c-- PERMIT # BUTTE COUNTY DEVELOPMENT SERVICES REVIEW D FOR . CODE CONI LANCE DATE_ BY�' O� COMP, B18-0098 PC 1/FILE 009-072-020 JANUARY 11, 2018 F/S FOR B1.7-191.2 s RESIDENTIAL FIRE SPRINKLER SYSTEM DESIGN BY FOX COMPANY C-16 LIC. # 305365 PER REQUIREMENTS OF NFPA 13D, 2016 EDITION JOHN GATELY GATELY HOME. 1261 LOSSER AVE 991 KENTUCKY GRIDLEY 95948 GRIDLEY' PLAN NUMBER 1757 1/10%18 WATER SOURCE IS PUBLIC UTILITY WATER PRESSURE IN' STREET 60. DEDUCT METER LOSS FOR SIZE '11-1 - 3 57. DEDUCT PRESSURE -LOSS FROM SOURCE TO SPRINKLER CONT.ROL'VALVE MAIN SECTION 'EQUIV.FT.. 1'' PIPE = 4.0 FT. 1 GATE VALVE = 1 FT. 1 CHECK VALVE = 4 - FT. 3 90 ELBOWS' _ 15 FT. 3 COUPLINGS = 3. FT. 0 TEES (RUN) = 0 FT. 0 TEES (BRANCH). = 0' FT. TOTALS 63, FT. X 1478 - 9:31 47.69 DEDUCT HEAD LOSS FOR ELEVATION ( 14 FT. X 0.434 ) - 6.08 41.61 DEDUCT PRESSURE LOSS FOR PIPING FROM CONTROL VALVE TO FARTHEST SPRINKLER. PIPE SECTION ONE EQUIV.FT. 1" PIPE. . _ 100 FT.. --_.__..... 3 .-9-0- ELBOWS . = 15. FT. 2. CROSSES _ 2 FT. 7 TEE(RUN) & 45 ELL = 7 FT. 2 TEES (BRANCH), = 10 FT. TOTALS _, 134 FT. X .1067 -14.30 27.31 BRAND.OF HEADS = GLOBE 4906 G:P.M.1- P:'S.I. CONVERSION FORMULA: K FACTOR OF HEADS USED = 4.9 (G..P.M:/ K FACTOR)2 = P.S.I. EQUIVALENT FEET CALCULATED @ 2 HEAD 2 HEAD= 26 G.P.M. FLOW ( .13 G.P.M. EA.) FRICTION LOSS `C' FACTOR = 150 MINIMUM PRESSURE REQUIRED = 7.04 P.S.I'. PRESSURE AVAILABLE IN SYSTEM = 27.31 P.S.I.. FIRE SPRI CORPORATION "THE I NCH" RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4906 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT DESCRIPTION AND OPERATION The Globe Model GL4906 Residential One Inch Adjustable Concealed Pendent Sprinkler has a flatplate profile that utilizes a 3mm frangible glass ampule as the thermosensitive element. Itfeatures economy, aesthetics and the lowest allowable water flow with a nominal 1"of adjustment for easier installation. The combination of the 3mm frangible glass ampule and specially designed deflector make the Model GL4906 the ultimate in life safety and fire control. It has met the strict requirements of Underwriters Laboratories Inc. as described in UL Standard, 1626, for Residential Sprinklers for Fire Protection Service, and should be used accordingly. This sprinkler should also be installed in accordance with the appropriate NFPA Standard 13, 13D or 13R and under the direction of the approving authorities having jurisdiction. All that is seen at the ceiling is the 3 5/16" diameter flat ceiling plate color finished to match the. specifier's exact requirements. The ceiling plate is soldered to the sprinkler's special.upper support assembly in three places. Upon the applicationof sufficient heat, the plate falls to the floorexposing the residential pendent spray sprinkler. Atthe prescribed temperaturethe internal pressurewithin the ampule exceeds the strength of the glass causing the glass bulb to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA • See reverse side for Approvals and Specifications. • Temperature Rating: 155°F (68°C) . Water Working Pressure Rating' 175 psi (12 Bars) • Factory. tested hydrostatically to 500 psi (34 Bars) * Maximum low temperature glass bulb rating: -67°F (-55°C) _ . * Frame -bronze • Deflector brass • Screw. brass • Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb -glass with alcohol based solution, 3mm size • Cover Plate - brass e Upper Escutcheon Assembly - steel RESIDENTIAL FLAT PLATE CONCEALEDPENDENT • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION BULB COLOR TEMPERATURES CEILING TEMPERATURE ORDINARYA I 1'5�s,'F 68°G RED fi{3tl°F' 8 G, 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 SEPTEMBER 2011 A-10 989-846-4583 • FAX 989-846-9231 BULLETIN GL49015, REV. #1 RESIDENTIAL AUTOMATIC SPRINKLERS MODEL GL4906 ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT . J SPECIFICATIONS AND APPROVALS SIN NOMINAL GL4906 12'x 12' 13 G.P.M. -.7 P.S.I. 14'x-14' 13 G.P.M. - 7 P.S.I. 155*F (68°C) . 18'x 18' 17 G.P.M. - 12 P.S.I. 20'x 20' 20 G.P.M. - 16.7 P.S.I. ' THREAD SIZE LENGTH FINISHES. SPRINKLER WITH . cULus MODEL "K" FACTOR . 135*F 57°C PLATE Bright Chrome White Painted GL4906 4.9 (68 metric) 1/2" NPT 3" (7.6 cm) Bright Brass* . X X Satin Chrome* Other Painted Finishes* NOTE: METRIC CONVERSIONS ARE APPROXIMATE. *FINISHES AVAILABLE ON SPECIAL ORDER. FOR PAINTED PLATES OTHER THAN WHITE, CONTACT GLOBE FOR ORDERING SPECIFICATIONS. INSTALLATION DATA FOR FLAT AND SLOPED CEILINGS** ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT MODEL MAXIMUM AREA OF MINIMUM WATER DISCHARGE 8L COVERAGE PRESSURES NEEDED PER SPRINKLER* GL4906 12'x 12' 13 G.P.M. -.7 P.S.I. 14'x-14' 13 G.P.M. - 7 P.S.I. 16' x 16' 13 G.P.M. - 7 P.S.I. 18'x 18' 17 G.P.M. - 12 P.S.I. 20'x 20' 20 G.P.M. - 16.7 P.S.I. NOTE: MINIMUM 9' SPRINKLER SPACING. 'WHEN THESE SPRINKLERS ARE USED IN NFPA 13 SYSTEMS, A 0.1 DESIGN DENSITY MINIMUM SHALL BE UTILIZED. *REFER TO PAGE 2 OF THE GLOBE RESIDENTIAL SPRINKLER INSTALLATION GUIDE FOR NFPA 13D and 13R REQUIREMENTS. ORDERING INFORMATION CROSS SECTION SPECIFY 23/4"DIA. MIN. - -Quantity • Model Number • Style HOLE IN CEIUNG • Orifice • Temperature • Finishes desired 23/8"DI4. . Quantity - Concealed Wrenches - P/N 332765 Quantity - Protective Caps - P/N 332868 REDUCER DROP 1SUPPORT SHELLN Rol {�}� 17/8" M N CEILING COVER PLATE) FLATPLATE 'CONCEALEDPENDENT ah GLW211% 19 IBE' FIRESI ;RUIN fN ERO?R#ORAMON SEPTEMBER 2011 COVER PLATE SIZE WHITE 135*F PART # CHROME 135°F PART # 3 5/16" 332892 332891 GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own.manu- factured products found to be defective in material or workmanship for a period of one year from date of ship- ment. For specific details of ourwarranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globespdnkler.com PRINTED U.S.A. BULLETIN GL4906, REV. #1 QUICK RESPONSE AUTOMAT/C SPRINKLERS GL SERIES UPRIGHT* PENDENT O VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7cm) 200T 286°F cULus FM Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7cm) MODEL FACTOR�� 57°C Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester 3 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7cm).Black LH X X X Polyester 23 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2cm) — METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16. 'FINISHES AVAILABLE ON SPECIAL ORDER. ' AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K IWF 155T 175T 200T 286°F cULus FM LPC CE NYC - DOB MODEL FACTOR�� 57°C 68°C 79°C 93°C 141°C MEA 101-92-E GL2815 2.8 LH X X X X X X — — — X GL4215 41 LH X X X X X X — — — X GL5615 5.6 ' UPRIGHT LH/OH X X X X X X X X X. X GL8115 7.8° LH/OH X X X X X X — — — X GI -8i 18 8.1 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X — — — X GL4201 4.2 LH X X X X X X — — — X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 7.8° LH/OH X X X X X X X — — X GL8106 8.1 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X — — — SIDEWALL' GL8133 8.1 LH X X X X X X — — — — GL2826 § 2.8 LH X X X X X X — — — X GL4226 § 4.2 LH X X X X X X — — — X HORIZONTAL GL5626 § 5.6 LH/OH X X. X X X X X — — X SIDEWALL GI -5627v 5.6 LH/OH X X X X X — — X X — GL8127 § 8.1 LH/OH X X X. X X X — — — — CONVENTIONAL GL5624 5.6 LH/OH XX X X X (OLD-STYLE)-- GL8125 8.1 - -LH/OH- X X X X- X 1SPRINKLERS SHALL BE LIMITED AS PER THE -REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. uINSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR V MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD °1/2" NPT ORDERING INFORMATION SPECIFY • Quantity • . Model Number • Style • Orifice • Thread Sizes • Temperature • Finishes desired • Quantity - Wrenches - P/N 325390 (1/2"); P/N 312366 (L. 0.) a�an �mIR ' tiara FIRE S PRINKl.M000RATIO-M JUNE 2012 GLOBE° PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 1-800-248-0278 PRINTED U.S.A. FAX 989-846-923.1 www.globesprinkler.com BULLETIN GL5615, REV.#9 DESCRIPTION AND OPERATION A/--r/rc QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT • PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster.than ordinary sprinklers. While the Quick Response Sprinkler provides an. aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers'the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains. a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. TECHNICAL DATA OF QUICK SPONSE UPRIGHT CONVENTIONAL iL42t5 QUICK RESPONSE PENDENT VERTICAL • See reverse side for Approvals and Specifications. SIDEWALL •Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141-C) • Water Working Pressure Rating -175 psi (12 Bars) • Factory tested hydrostatically to 500 psi (34 Bars) Ink • Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE • Frame - bronze • Deflector - brass • Screw - brass HORIZONTAL LPC/CE SIDEWALL HORIZONTAL *Lodgement Wire -stainless steel • SIDSIDEWALL • Bulb seat -copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm size -SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX989-846-9231 JULY 2012 A-20 BULLETIN GL5615, REV. #9 AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION BULB COLOR TEMPERATURES CEILING TEMPERATURE ORDINARY 35"F1155 °F ���aZ�CI$8° ORANGE/RED 10th°1.386,, INTERMEDIATE 175°F/200°F 79°C/93,' YELLOW/GREEN 150°F: a :' 66°G HIGH 286'E 141°G BLUE .:..225°F�. _ . ,. ;..107°C 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX989-846-9231 JULY 2012 A-20 BULLETIN GL5615, REV. #9 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT* PENDENT ®'VERTICAL SIDEWALL HORIZONTAL •SIDEWALL • CONVENTIONAL (OLD STYLE SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/ 4" (5.7cm) 200T 286°F cULus FM Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7cm) MODEL FACTOR • 57°C Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7cm) LH X X X Black Polyester z,3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2cm) — METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9116". ' FINISHES AVAILABLE ON SPECIAL ORDER. ' AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS STYLE SIN K HAZA RD' 135T 155T . 175°F 200T 286°F cULus FM LPC CE NYC - DOB MODEL FACTOR 57°C 68°C 79•C 93°C 141°C MEA 101-92-E GL2815 2.8 LH X X X X X X - — — X LH X X X X X X — — — X GL5615 5.6 UPRIGHT LH/OH X X X X X X X X X X GL8115 7.8• LH/OH X X X X X X — — — X GL8118 8.1 LH/OH X X X X X X X X X X GL2801 2.8 LH . X X X X X X— — — X GL4201 4.2 LH X X X X X X — — — X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 7.8• LH/OH X X X X X X X — — X GL8106 8.1 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH . X X X X X X X — — — SIDEWALLt GL8133 8.1 LH X X X X X X — — — — GL2826 § 2.8 LH X X X X X. X — - — X GL4226 § 4.2 LH X X X X X X — — — X HORIZONTAL GL5626 § 5.6 LH/OH X X X X X X X — — X SIDEWALL GL5627o 5.6 LH/OH X X X X X — X X — GL8127 § 8.1 LH/OH X X X X X X — — — — CONVENTIONAL GL5624 5.6 LH/OH X X X X X — — .X X — (OLD-STYLE) -" GL8125 8.1 LH/OH -X X-- X X X — = X X — 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cUl-m LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. oINSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. 1PENDENT VERTICAL SIDEWALL cULus LISTED FOR G MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD •1/2" NPT ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY • Quantity • Model Number • Style Globe agrees to repair or replace any of its own manufactured • Orifice • Thread Sizes • Temperature products found to be defective in material or workmanship for a •Finishes desired period of one year from date of shipment: • Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and'Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 -� 989=846-4583 FAX 989-846-9231 FIRE. SPAINKI.EMROatAvok 1-800-248-0278 www.globesprinkler.com JUNE2012 PRINTED U.S.A. BULLETIN GL5615,REV. #9 U) - W J a� W. N Z 0 Bronze Spring Loaded Check Valve %"-2" Figure No. 3600 w/Teflon Disc. Figure NO: 3600SJ w/Teflon Disc Figure No. 3615. w/Buna-N Disc Figure No. 3615SJ w/Buno-N Disc 125 PSI Saturated Steam, with TFE Disc Buna-N Disc Rated at 250 PSI 250 PSI Non -Shock Cold Water, 011, or Gas Fluid Pressure, Non -Shock W.O.G. lure No. 3600 lure No. 3615 Threaded Grinnell check.valves may be installed in vertical lines with upward flow or in any intermediate position. Do Not Use For Reciprocating Air Compressor Service. Do Not Use as a Footvalve. Q) Figure No.'3600SJ Figure No:'3615SJ Copper to Copper x`�����-„�' ..ky''.�.•`"D'•,jik4"�`.77 �}-�-'ie��'� .,r.: �r 1 .l..yjG�✓�y}N 'i��;�'.ilr wrv3..., •..�',• zt� ��+ 7: E?.1:.. a c}�"C. ,{�i: ;t• -ii.'-+.:^', F,i •.��?:i �'A' '�':•::i+. ,. .� � , r,:�!r •`Z�z-.tiii�i " +� � � ' e � Maai��l>'il Lisi - •;, =�:, Ditnensioits —Weights Nominal Size Part Specification 1. Body -Bronze ASTM B-584 Alloy C84400 2. Stem' Stainless Steel ASTM A-582 Alloy S30300 3. Spring 316 Stainless Steel 4. Disc Holder Stainless Steel Type 301 S. Disc Teflon, Fig. 3600 5A. Disc Buna-N, Fig. 3615 6. Seat Ring Teflon 7. 8. Seat Screw Body End Stainless Steel ASTM A-276 Alloy S43000 Bronze ASTM B-584 Alloy CB4400 Nominal Size DimensionsApprox. NNet wt. Fig. 3600 Approx. NNet wt. Fig.3600SJ A B C 3/6 2 11% i7/16' .4 4 112 21/6 13/6 13/16 .4 .4 314 2114 1516 1S/16 .5 .5 1 25/e 2 V/2 .8 .9 11/4 Vshs 23/6 11,/16 1.2 1.3 1t/2 35/16 23/4 2 1.6 1.9 2 33/4 33/6 1 25h. 2.4 2.7 no FIRE'SPRINKLER, -PRESSURE GAUGES-.- US. GUAGE, -AMETEK r • Use on wet, or dry. sprinkler systems!, • So11d brass-backed! /,.. A .NTP-LM brass fitting; 3'/2" diameter , 300. lb./sq. In'. capacity 25 »s . 300 LISTED 'M APPROVE VSR-SF (R)P0 ER VANE TYPE WATERFLOW O AOR SMALL PIPE ALARM SWITCH WiTH REYARD Potter Electric Signal Company potter Electric Signal & Mfg. LTD 2081 Craig Road • P.O. Box 28480 1967 Leslie Street St. Louis, MO 63146-4161 Don Mille, Ontario, Cant M362M3 (314) 8784321 6 (800) 325.3936 (416) 441.1833 UL. ULC, C8FM LISTED and NYMEA ACCEPTED Service Pressure: ' Up to 250 PSI Minimum Flow Rate for Alarm: 10 GPM Maximum Surge: IS FPS Enclosure: Die-cast, red enamel finish. Cover held In place wtth tamper resistant adewe Canted Ratings: Two seta of SPOT (Form C) 16.0 Amps at 123%250 VAC 2.0 Amps at 0.30 VDC Cvrtdult Entrsnoas: Two Knockouts provided for iR' condutt Uaapo: Usted Plastic, Copper and Schedule 40 Iron Pipe Fite pipe Blies - 1', 1 1/4', and 1 In' Note: 0 paddies are furnished with each unit. one for each pipe size of threaded or sweat TEE, one for 1' CPVC, and one for 1 1/2' polybutylene (CTS -Copper tubing size) Envlronraanbl 9Peolfleatlons. Sultable for Indoor or outdoor use with factory Installed gasket and die-cast housing NEMA 4 Rated Enclosure • use with appropriate conduit. fitting Tomperature'Range: 40' F/120° F (4.5° C -/4V C) Caution: Thle device Is not intended for applications In exploeNs environments Service Use: -: Automatic Sprinkler NFPA-13 One of two famlly dwelling NFPA-130 STK. NO. 1113000 Residential occupancy up to tour stories NFPA-ISR U.S, PAT. NO.3921989, CANADIAN PAT. NO.4009680 National Fire Alarm Code NFPA-y2 OTHER PATENTS PENDING. 4 Optional: Cover Tamper Switch, order Stk. No. 0090016 The Model VSA -SF is a vane type waterllow switch for use ori wet sprinkler The vane must not rub the Inside of the TEE or bind In any way. The stern systems that use 1%'d 1/4', or 1 1/2' pipe size. The unit may also be used should move freely when operated by hand. is a esotionak'wateiflow detector on large systems. The device can also be used in copper or plastic pipe Installations with the The unh contains two single pole double throw snap meson switches and proper adapters so that the apeclfled TEE ft"msy be Inetalked an the an adiustable:pneumatic retard. The switches are actuated when a floW Of pipe run. - - -10 gallons per minute or more occurs downstream of the d6Wi.ThedfoW , condition moat exist for a period of time necessary to ova- -z ' the INSPECTION AND TESTINQ: Check the operation of the unit by opening selected ralard period. i 1 the Inspector' tssi valve at the end of the sprinkler line or the drain and test bonnecUon, If an Inspector's test valve to not provldad. INSTALLATION: These devices may be mounted In horizontal or verb W pipe. On horizontal pipe they should be Installed on the top aide of the pipe where they will be accessible. The units should not be Installed Wlthln Be of &valve, draln'or fkning which charges the dlrection of the waterflow. The unit has a 1' NPT bushing for threading Into a noncorrosive TEE, See Ftp, 2 for proper TEE size, type and installation. 8crewthe device Into the TEE fitting as shown In Flg.2. Cars must betaken to property orient the device for the direction of waterflow. . . If !hers are no provisions for tenting the operation of the flow detection device on the system, epplleation of the VSR-9F is not fee6mrnende8 or 'advluble The kaquenoy of the inspection and testing and Its aesooillied protective moriltorhq system should be in accordance with the applicable NFPA Codes and Standards and/or authority having Jurisdiction (manufacturer reoommends quarterly or more frequently). les have ed that shows the CAUTION: There are thates furnished with each unit. theyt be used with The properlpaddleese dMuM be used.The screwahat holds adde size and type of TEE the y must be sectirery tightened. MKT. 06401=1 • REV I aActE t OF 2 PRINTED IN USA MFG. 0940011211 - 3109 POT 'BELLS PBA -AC &PB D_ DC Potter Electric Signal Company Potter Electric Signal & Mfg. LTD 2081 Craig Rd., P.O. Box 28480 1967 Lesiie,Street St. Louis, MO 63146 Don Mills, Ontario, Canada M31B2M3 (314)878-43211 (800) 325-3936 (416) 441-1833 UL LISTED, FM APPROVED Sizes Available: 6", 8", and' 10° Voltages Available: 24VAC 120VAC y`. 12VDC (10.2 to 15.6) Polarized 'n 24VDC (20.4 to 31 '2) Polarized • Service User Fire Alarm General Signaling Burglar Alarm Environment: Indoor or Outdoor Use (See Note 1) -400 to 150°F (outdoor use require -weatherproof backbox) Termination: 4 No. 18 AWG stranded wires Finish: Red powder coating 6" BELL SHOWN Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, .burglar,, or:general signaling devices...-doorThey :have low power consumption and high decibel ratings. The unit mounts on a standard 4"square electrical box for in use, or on a model BBK-1 weatherproof backbox for outdoor applications.. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: SIZE VOLTAGE MODEL NO.' STOCK NO. CURRENT (MAX) TYPICAL d8 0 10 FT. MINIMUM d8 . 6 12VDC PBD126 1706012 .12A 85 75 8 12VDC PBD128 1708012 .12A 90 75 10 12VDC PBD1210 1710012 .12A 92 75 '. 6 24VDC PBD246 1706024 .06A 87' 75 8 24VDC PBD248 1708024 .06A 91 79 10 24VDC PBD2410 1710024 .06A 94 79 6 24VAC PBA246 1806024 .17A 91 75 8 24VAC PBA248 1808024 .17A 94. 75 10 24VAC PBA2410 :. 1810024 .17A 94 75 - 6 120VAC PBA1206. 1806120 .05A 92 82 8 120VAG PBA1208 1808120 .05A 99 82 10 120VAC PBA12010 1810120 .05A 99 85 Weatherproof backbox model BBK-1 Stk. No. 1500001. Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is •30° to 150°F. 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. PRINTED IN USA MKT. #8850001- REV K PAGE 1 OF 2 MFG. #5400776 - 4/94 9600KLINGERMAN STREET * P.O. BOX 3365 O SOUTH EL MONTE, CA 91733 *USA 920 TEL: 626.444.0541 * FAX: 626.444.3887 E-MAIL : info@afcon.org * www.afcon.org C(S)U-s CPUC -'STEEL - COPPER #510 #511 #514 0 0 Patented 0 o . • Installation Instructions ' Install on CPUC pipe as a hanger and/or restrainer -per. th.eir.engveering_.sheets. Some are.additionally . .listed, for use for use with steel and copper pipe. #510:& #�14 install on top, bottom or side -of beam. #511. install on,top or bottom of beam. #513 'install on top or side of beam. #515 & 519 install on side�of beam. Required fasteners furnished: "#904 for #515 C.PN.C. Max. Hanger #905 for#51.9 thru #514' Pipe Size . Spacing 3M ------ ------- .� I------ 6 11/4 ------------ 61/2 1 I;2 — — 7 2------------ Y 2 1/2------- ------ 9 3 10