Loading...
HomeMy WebLinkAbout009-330-015DEVELOPMENT SERVICES BUTTE COUNTY AREA DEPARTMENT OF DEVELOPMENT SERVICES 1 INSPECTION CARD MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm) Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530.538.7785 www.ButteCounty.net/dds Permit No: B17-0953 Issued: 5/17/2017 APN: 009-330-015 Address: 1678 GRACE RD, BIGGS Owner: SAMPLE BESSIE I TRUST Permit Type: SOLAR ROOF -RES Description: SOLAR ROOF - RES 4.58KW Flood Zone: None SRA Area: No Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline of Road: ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Inspection Type IVR INSP DATE Setbacks 131 Foundations / Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120 Setbacks 131 Do Not Pour Concrete Until Above are Signed Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under Slab Plumbing 411 Blockin nde inin 612 Tiedown/Soft Set System 611 Do Not Install Floor Sheathing or Slab Until Above Signed Shearwall/B.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 417 Manometer Test Do Not Install Siding/Stucco or Roofing Until Above Signed Rough Framing 153 Rough Plumbing 406 Rough Mechanical 316 Rough Electrical 208 4 -Way Rough Framing 128 Gas Pi ing House 403 Gas Test House 404 Shower Pan/Tub Test 408 Do Not Insulate Until Above Signed Permit Final 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler Test or Final 702 Swimming Pools Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimming Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 1 503 Pre -Plaster 507 Manufactured Homes Setbacks 131 Blockin nde inin 612 Tiedown/Soft Set System 611 Permanent Foundation System 613 Underground Electric 218 Sewer 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Skirting/Steps/Landings 610 Coach Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Finals Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final "PROJECT FINALZ5<( -rrojecE rural is a %-ernncace of occupancy for txesTuennaE vnly) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED, YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION (IVR)#:530.538.4365 OFFICE #: 530.538.7601 FAX#:530.538.7785 www.ButteCounty.n'et/dds Contractor PROJECT INFORMATION HOOKED ON SOLAR INC Site Address: 1678 GRACE RD 4035 GRASS VALLEY HIGHWAY Owner: ' r Permit No: B 17-0953 APN: ' . 009-330-015 5303203949 SAMPLE BESSIE I TRUST 0 0 0 .LICENSED:CONTRACTOR'S DECLARATION 'Permit type: MISCELLANEOUS ' DECLARATION 1678 GRACE RD • I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for Issued Date: 5/17/2017 By . JMD Subtype: - SOLAR ROOF -RES 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure; prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' GRIDLEY, CA 95948 (commenting with Section 7000) of Division 3 of the Business and Professions Code, and my license i Expiration Date: 5/17/2018 Description: SOLAR ROOF - RES 4.5EKW 4; X Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of Occupancy: Zoning: Contractor Applicant: Square Footage: HOOKED ON SOLAR INC HOOKED ON SOLAR INC Building Garage Remdl/Addn 4035 GRASS VALLEY HIGHWAY 4035 GRASS VALLEY 0 0 .0 AUBURN, CA 95602 AUBURN, CA 95602 Other Porch/Patio Total 5303203949 5303203949 0 0 0 .LICENSED:CONTRACTOR'S DECLARATION OWNER/ BUILDER DECLARATION Contractor (Name) State Contractors License No. / Class / Expires I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for HOOKED ON SOLAR • 949707 / B./ 6/30/2019 the reason(s) indicated below by the checkmark(s) I have placed next to the applicable item(s) (Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure; prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors' I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I an licensed under provisions of Chapter 9 (commenting with Section 7000) of Division 3 of the Business and Professions Code, and my license i Stale License Law (Chapter 9 (commencing with Section 7000) of Division 3 of the Business and in full force and effect. Professions Code) or that he or she is exempt from licensure and the basis for the alleged exemption. 4; X Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): as owner of the property, or my employees with wages as their sole compensation, will El Contractor's Signature " Date do do U all of or U portions of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the Owner -Builder will have the ,WORKERS','COMP.ENSATION DECLARATION - I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of he following declarations: r have and will maintain a certificate of consent to self -insure for workers' burden of proving that it was not built or ❑I compensation issued by the Director of Industrial Relations as provided for by Section improved for the purpose of sale.). 3700 of the Labor Code, for the performance of the wo:k for which this permit is issued. Policy No. ❑I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: i Cartier. STATE PolicyNumbam5o715 Exp.2017 ❑e 1 certify that, in the performance of the work for which this permit is issued, I shall not mploy any person in any manner so as to become subject to the workers' compensation laws of California, and agree that, if I should become subject -to the workers' compensation provisions of Section 3700 of the Labor erode, I shall forthwith comply with those provisions. -, X Signature Date WARNING: FAILURE TO SECURE WORKERS' CC'MPENSATION COVERAGE IS UNLAWFUL, AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE LABOR CODE, INTEREST., AND ATTORNEY'S FEES. CONSTRUCTION; LENDING 'AGENCY DECLARATION I hereby affirm under penalty of perjury that there is a constriction lending agency for the Performance of the work for which this permit is issued (Section 3097, Civil Code). Lenders Name and Address I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State License Law.). . ❑I am exempt from licensure under the Contractors' Slate License Law for the following reason: Owner's Signature Date PERMIT APPLICANT DECLARATION By my signature below, I certify to each of the following: I am L) a California licensed contractor or U the property owner' or U authorized to act on the property owner's behalf 1 have read this construction permit application and the information I have provided is correct. I agree to comply with all applicable city and county ordinances and state laws relating to building construction. I authorize representatives of this city or county to enter the above -identified property for inspection purposes. California Licensed Contractor, Property Owner' or Authorized Agent": 'requires separate verification form "requires separate authorization form X Lender's Name & Address C ty State Zip a; FEE INFORMATION t T)tal Fees: $445.00 Fees Paid: $445.00, Balance Due: (None) Job Value: $16,000.00 • � F SHEETINDEX PV -1.0 COVER & NOTES PAGE PV -2.0 SITE PLAN PV -3.0 ANCHOR & DETAILS PV -4.0 ELECTRICAL DIAGRAM & CALCS PV -5.0 ACPV MODULE -INVERTER SPEC PV -6.0 RACKING METHOD PV -7.0 MOUNTING AND FLASHING PV -8.0 GROUNDING METHOD PV -9.0 SAFETY LABELS PV -10.0 MICRO INVERTER MAP (FIELD USE) LEGEND .�. PROPOSED EXISTING (P) (E) ELECTRICAL ' EQUIPMENT - � •VENTS Q • APPLICABLE CODES: • 2016 CALIFORNIA BUILDING STANDARDS (CBC) • 2016 RESIDENTIAL BUILDING CODE (CRC) • 2016 CALIFORNIA ELECTRICAL CODE (CEC), • ' 2016 CALIFORNIA FIRE CODE (CFC).. •• REFERENCE SEC. 605.11.1. •• SMOKE DETECTORS AND CARBON MONOXIDE ALARMS SHALL BE INSTALLED IN ACCORDANCE WITH CRC R314 AND CRC R315. o. w ' 1678 Grace Road o d o c. a a .a Colusa Hrty - COiusa I-I%Vy W r. C n x y N PROJECT SITE NTS 1814 SAMPLE FIRE ACCESS NOTES: 1. ALL SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE WITH UL217 AND INSTALLED IN ACCORDANCE WITH THE PROVISIONS OF THIS CODE AND THE HOUSEHOLD FIRE WARNING EQUIPMENT PROVISIONS OF NFPA 72: SYSTEMS AND COMPONENTS SHALL BE CALIFORNIA STATE.FIRE MARSHAL LISTED AND APPROVED IN ACCORDANCE WITH CA CODE OF REGULATIONS, TITLE 19, DIVISION 1 FOR PURPOSE FOR WHICH THEY ARE INSTALLED. 2. T ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH ASWINDOWS OR'DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION -1N LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS 3. SOLAR PANELS SHALL BE NO HIGHER THAN 3 FEET BELOW THE RIDGE IN ORDER TO ALLOW FOR FIRE DEPARTMENT SMOKE VENTILATION OPERATIONS GENERAL NOTES: - 1. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE " " POWV R� WARRANTED. 2. THE SOLAR PV SYSTEM WILL BE INSTALLED IN ACCORDANCE by Hooked on Solar WITH ARTICLE 690 OF THE 2016 CEC AND 2016 CRC. 3. PER CEC 705.12 d 7 , LOCATION OF BACK FED BREAKER SHALL ( )( ) SSESORS PARCEL #: BE INSTALLED FARTHEST / OPPOSITE END FROM THE MAIN 000-000-000 OVER -CURRENT DEVICE OR MLO. PARCEL ACRES: 0 O.00AC 4. WHERE METALLIC CONDUIT CONTAINING DC CONDUCTORS IS USED INSIDE THE BUILDING, IT SHALL BE IDENTIFIED AS "CAUTION: SOLAR CIRCUIT" EVERY 1OFT. 5. A DC DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY ACCESSIBLE LOCATION EITHER OUTSIDE OF THE BUILDING OR STRUCTURE OR INSIDE NEAREST POINT OF • ENTRANCE OF THE SYSTEM CONDUCTORS AS PER SECTION 690.14 OF THE CEC. 6. HEIGHT OF THE INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC CODE 240.24. 7. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH ` CEC 690.47 AND 250.50 THROUGH 60 AND 250-166 SHALL BE PROVIDED: PER CEC GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO THE SERVICE ENTRANCE: IF EXISTING SYSTEM IS INACCESSIBLE OR SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58 kW AC - MODULES: (16) SPR -;20 -327 -`C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18° IMUTH: -• 270' INSTALL TYPE: COMP INADEQUATE A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL SP LEASE # 1067829 LISTED 8 FT. GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO LARGER THAN #6 AWG COPPER AND BONDED TO THE SIGNED BY: EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 8. PHOTOVOLTAIC MODULES ARE TO BE CONSIDERED NON-COMBUSTIBLE. 9. PHOTOVOLTAIC INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING. MECHANICAL, OR BUILDING ROOF VENTS. THE SMOKE ALARMS SHALL BE INSTALLED OR VERIFY TO ENSURE THE SMOKE ALARMS ALREADY EXISTING WHEN ALTERATION OR REPAIR TO GROUP R-3 OCCUPANCY EXCEEDS $1,000 CRC R314.6. CARBON MONOXIDE NOTES: 1. CARBON MONOXIDE ALARMS ARE REQUIRED AT THE .FOLLOWING LOCATIONS: 1.1. ON THE CEILING OR WALLS OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS 1.2. ON EACH STORY WITHIN A DWELLING UNIT, INCLUDING ' ! BASEMENTS. _. t1.3. THE CARBON MONOXIDE ALARMS SHALL BE LISTED AS ? COMPLYING WITH THE REQUIREMENTS OF UL 20.34. CARBON - MONOXIDE DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THIS CODE, THE CURRENT EDITION OF NFPA 720 "STANDARD FOR THE INSTALLATION OF CARBON MONOXIDE (CO) DETECTION AND WARNING EQUIPMENT" AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS PER 2016 CRC SECTION R315.3. DRAWN BY: AGN CHECKED BY: JAA DESCRIPTION DATE REV CUSTOMER NAME: JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 buckshotjohn50@gmaii.com SHEET TITLE: COVER/ SITE PLAN PROJECT #: 1814 SAMPLE SHEET #: 1.0• DATE: 5/11/17 1:10 • SUNPOWER f r by Hooked on Solar SSE_SORS PARCEL #: -Lt, + 000-000-000 PARCELACRES: F' O.00AC 41 w SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58 kW AC MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18' AZIMUTH: 270' INSTALL TYPE: COMP s CHECKED BY: JAA DESCRIPTION DATE REV j CUSTOMER NAME:' JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 buckshotjohn50@gmail.com SHEET TITLE: SITE PLAN PROJECT #: 1814 SAMPLE SHEET #: 2.0 DATE: 5/11/17 i { SP LEASE # 1067829 - . d -. .a� ?: - .7..; -.., , C' - }'• -- Y' y., d �,. is : , i • ij F1 - . ; ,, , r , SIGNED BY: �Y -.: C :%�..- , ' .. Y , , . .,� 4 •, kat' f 4 SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58 kW AC MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18' AZIMUTH: 270' INSTALL TYPE: COMP s L_ J 12.1 �i.` P\L I , rw I .l ^+ -,y 3..=.l•!.. -.{ — — — — — — — — — J '4 _ '# �,�,'#P" { +� r ' •,.•..,'t -�,-'fw;,.•t.-.-r..•` is .F — � .4'i - I t -.. ''' _ � .+^ •,Y•��. (�) MAIN.5FPNICF PML r I .(p) ,COMMUNICA110N5 DRAWN BY: AGN CHECKED BY: JAA DESCRIPTION DATE REV j CUSTOMER NAME:' JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 buckshotjohn50@gmail.com SHEET TITLE: SITE PLAN PROJECT #: 1814 SAMPLE SHEET #: 2.0 DATE: 5/11/17 i { SP LEASE # 1067829 - . d -. .a� ?: - .7..; -.., , C' - }'• -- Y' y., d �,. is : , i • ij F1 - . ; ,, , r , SIGNED BY: �Y L_ J 12.1 �i.` P\L I , rw I .l ^+ -,y 3..=.l•!.. -.{ — — — — — — — — — J '4 _ '# �,�,'#P" { +� r ' •,.•..,'t -�,-'fw;,.•t.-.-r..•` is .F — � .4'i - I t -.. ''' _ � .+^ •,Y•��. (�) MAIN.5FPNICF PML r I .(p) ,COMMUNICA110N5 DRAWN BY: AGN CHECKED BY: JAA DESCRIPTION DATE REV CUSTOMER NAME:' JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 buckshotjohn50@gmail.com SHEET TITLE: SITE PLAN PROJECT #: 1814 SAMPLE SHEET #: 2.0 DATE: 5/11/17 1:10 a 2 L -FOOT RAIL MODULE 7 1.25 DECK ` (E) 2x4(TRUSS/RAFTER) 2x6 RAFT i i 3.00 ANCHOR WITH I I ` FLASHING• , ." I i I J 1 " — ALLOWED LAG 4INSTALLATION ZONE 7_71 ROOF AND MODULE PROFILE ANCHOR DETAIL`` t SUNPOWERG by Hooked on Solar' SSESORS PARCEL* 000-000-000 PARCEL ACRES: O.00AC SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58 WV AC MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18° AZIMUTH: 270' INSTALL TYPE: COMP (E) TRUSS LAYOUT 24^ O.C. SP LEASE # 1067829 I I RAIL I ANCHOR, , I , 6'm ANCHOR ' I HORIZ NTALACIN I I !- SIGNED BY: 13'MINIFIRE'S BACK IFS-f---�=�.. • •' I I + I I 1 I I I- 1 I'- .' I 1 I "I I 1 1 f I I I ,1 - i� , - I I 1 I' I I• 1 1 I 1 I 1 'I I 1 I I 1 1 I I I II I� • I I V I I I I� I I I 'I I � I I - Y I - �L 'I �L I- I I I 1 - I I I• -I I� • I I� I� I I , ' - I I I• I I I I 1 I 1' - I II I I I I 1 I I- I I I I I I I I I I I 1 1 I II I • I 1 1 1 I I I I I I 1 I I I I - I � I I I I I I I I ' I I NOTES: y 1. RAILS TO'BE 2" MIN -14" MAX FROM EDGE OF PANEL WHEN IN LANDSCAPE ORIENTATION. 2. RAILS TO BE 2" MIN - 16" MAX FROM EDGE OF PANEL WHEN IN PORTRAIT ORIENTATION. DRAWN BY: AGN CHECKED BY: JAA ,DESCRIPTION DATE REV CUSTOMER NAME: JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 buckshotjohn50@gmail.com SHEET TITLE: COVER/ SITE PLAN PROJECT#: 1814 SAMPLE SHEET #: 3.0 DATE: 5/11/17 NTS I EXISTING: MAIN SERVICE PANEL RATINGS MFG/MODEL CUT HAM BUS AMP RATING 125 A SERVICE VOLTAGE 240 V MAIN OCPD RATING 100 A TOTAL SYSTEM RATING 40 A TOTAL INVERTER RATING ?'' 40 A AC SUB PANEL RATINGS BUS AMP RATING 125 A SERVICE VOLTAGE 240 V MAIN OCPD RATING 30 A INVERTER OCPD RATING AS SHOWN AC SUB PANEL RATINGS BUS AMP RATING 125 A SERVICE VOLTAGE 240 V MAIN OCPD RATING 30 A INVERTER OCPD RATING AS SHOWN AC DISCONNECT DG221 NRB USE 30A FUSE - DISCONNECT AMP A RATING 30 DISCONNECT VOLT 240 V RATING AZIMUTH: i DC A DC A A DC MAX OF 12 MODULES IN A CIRCUIT #1 BRANCH CIRCUIT - THIS CIRCUIT HAS 12 MODULES. ACPV SUPERVISOR MODULE #1 MODULE #2 MODULE #12 SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58.kW (AC) MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18° - 270°� INSTALL TYPE: ' COMP • M „ SUNPOWERc. REV by Hooked on Solar ]-BOX AZIMUTH: - L NEMA 311 MINIMUM INSTALLER NOTE: CUSTOMER NAME: JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 - buckshotjohn50@gmail.com ' SHEET TITLE: ELECTRICAL DIAGRAM & CALCULATIONS REQUIRED WITH SHEET #: 4.0 DATE: '5/11/17 INVERTER OUTPUT CIRCUIT CONDUCTORS ARE ASSESORS PARCEL #: WATERPROOF SPLICES POLARITY SENSITIVE. (P) RAIL (TYP) 000-000-000 OR OTHER APPROVED PARCEL ACREO.00AC TERMINATION HOOKED ON SOLAR SHALL BE OBLIGAT4MATCH METHOD. CONDUCTORS FROM TRANSITION CABL A D A DC A DC ACPV OUTPUT CONDUCTORS. RECEPTACLE PROTECTIVE J -BOX 20 A INSTALLED ON THE LAST MODULE CABLE OF THE BRANCH CIRCUIT i DC A DC A A DC MAX OF 12 MODULES IN A CIRCUIT #1 BRANCH CIRCUIT - THIS CIRCUIT HAS 12 MODULES. ACPV SUPERVISOR MODULE #1 MODULE #2 MODULE #12 SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58.kW (AC) MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18° - 270°� INSTALL TYPE: ' COMP • t MAIN a MODULE #1 MODULE #2 MODULE #4 SUB. SUB . INSULATED EGC EXISTING SEE NOTE 3 FOR INVERTER 8 AWG, GREEN LOADS CONDUIT TYPE: ROMEX CONDUIT SIZE: 12 3 CONDUCTOR TYPE: THWN-2 CONDUCTOR SIZE: 12 AWG + - MI IMRFG IIF rnNnl I(:TnRS: L RED, 2 BLACK, 2 GRND) t . SEE NOTE 4 FOR INVERTER SEE NOTE 4 FOR INVERTER CONDUIT TYPE: EMT CONDUIT TYPE: EMT 34" ` CONDUIT SIZE: CONDUIT SIZE: 3 4" CONDUCTOR TYPE: THWN-2 CONDUCTOR TYPE: THWN-2 , CONDUCTOR SIZE: 10 AWG CONDUCTOR SIZE: 12 AWG ' NUMBER OF CONDUCTORS NUMBER OF CONDUCTORS: L RED, 1 WHITE, 1 BLK, 1 GREEN) (1 RED, 1 WHITE, 1 ELK, 1 GREEN) EGC SIZE 8 AWG (NEC 250.122) EGC SIZE -8 AWG (NEC 250.122) NOTES FOR INVERTER CIRCUITS 1) IF UTILITY REQUIRES A VISIBLE -BREAK SWITCH, DOES THIS SWITCH MEET ' THE REQUIREMENT? YES X NO N/A + 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES . NO N/A X . 3) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. 4) TOTAL OF 1 INVERTER OCPD(S), ONE FOR EACH INVERTER, DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(8)(2)(a)? YES X NO N/A 5) INVERTER CALCULATIONS PER ACPV AS SHOWN: 1.X 1.33A (MAX OUTPUT) X.99 (POWER FACTOR) X 1.25% = 1.645875A / ACPV DRAWN BY: . AGN M „ DATE REV AZIMUTH: - L CUSTOMER NAME: JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 - buckshotjohn50@gmail.com ' SHEET TITLE: ELECTRICAL DIAGRAM & CALCULATIONS PROJECT #: 1814 SAMPLE SHEET #: 4.0 DATE: '5/11/17 A D A DC A DC 20 A Ac •• SP LEASE # 1067829 2py� tibrho e) - DISCONNECT MAX OF 12 MODULES IN A ((•d I �40'Jl // 30 A 20 A ' CIRCUIT #2 BRANCH CIRCUIT - THIS �Qb CIRCUIT HAS 4 MODULES. j •49.A r 15A SIGNED BY:Fe t MAIN a MODULE #1 MODULE #2 MODULE #4 SUB. SUB . INSULATED EGC EXISTING SEE NOTE 3 FOR INVERTER 8 AWG, GREEN LOADS CONDUIT TYPE: ROMEX CONDUIT SIZE: 12 3 CONDUCTOR TYPE: THWN-2 CONDUCTOR SIZE: 12 AWG + - MI IMRFG IIF rnNnl I(:TnRS: L RED, 2 BLACK, 2 GRND) t . SEE NOTE 4 FOR INVERTER SEE NOTE 4 FOR INVERTER CONDUIT TYPE: EMT CONDUIT TYPE: EMT 34" ` CONDUIT SIZE: CONDUIT SIZE: 3 4" CONDUCTOR TYPE: THWN-2 CONDUCTOR TYPE: THWN-2 , CONDUCTOR SIZE: 10 AWG CONDUCTOR SIZE: 12 AWG ' NUMBER OF CONDUCTORS NUMBER OF CONDUCTORS: L RED, 1 WHITE, 1 BLK, 1 GREEN) (1 RED, 1 WHITE, 1 ELK, 1 GREEN) EGC SIZE 8 AWG (NEC 250.122) EGC SIZE -8 AWG (NEC 250.122) NOTES FOR INVERTER CIRCUITS 1) IF UTILITY REQUIRES A VISIBLE -BREAK SWITCH, DOES THIS SWITCH MEET ' THE REQUIREMENT? YES X NO N/A + 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES . NO N/A X . 3) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. 4) TOTAL OF 1 INVERTER OCPD(S), ONE FOR EACH INVERTER, DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(8)(2)(a)? YES X NO N/A 5) INVERTER CALCULATIONS PER ACPV AS SHOWN: 1.X 1.33A (MAX OUTPUT) X.99 (POWER FACTOR) X 1.25% = 1.645875A / ACPV DRAWN BY: . AGN CHECKED BY: JAA DESCRIPTION DATE REV - L CUSTOMER NAME: JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 - buckshotjohn50@gmail.com ' SHEET TITLE: ELECTRICAL DIAGRAM & CALCULATIONS PROJECT #: 1814 SAMPLE SHEET #: 4.0 DATE: '5/11/17 ` - '�^'y�Y .a •` a... w;•�7 �� -il-� ter. i Mat* 4 i ate_ .��_ _ t..r... �-. � ®__ � � ��_..�.�I ..t,. •F, Design -Driven Advantages t ' X , #1 module aesthetics and efficiency, - Unmatched module reliabilityz j No electrolytic capacit6rs + 25 -year Combined Power and Product ' Warranty Maximize Value for.Roof r ' Size system for roof, not string inverter �1 Optimize performance of each module, 1 Expand Deployment Options Complex roofs and partial shading f Small`systems SERIES M System expandability aml= • Simplify & Speed Installation Optimize System and Installation Efficiency F Factory -integrated microinverter 327 W _ Robust, double -locking AC connectors r - SunPower° AC Modules, which include a factory -integrated - Design flexibility offsite and onsite ; SunPower microinverter, provide a revolutionary combination of high No DC string sizing process t efficiency, high reliability, and module -level DC -to -AC power conversion. ' Fewer installation steps than competing . Three bypass diodes Integrated module -level maximum power point tracking systems Designed specifically for use with SunPower InvisiMountTM and the Intuitive commissioning SunPower Monitoring System, SunPower AC Modules enable rapid 1 Component of Complete System installation, best -in -class system aesthetics, and intuitive visibility into Built for use with SunPower® InvisiMountTM' system performance. All this comes with the best Combined Power and the SunPower Monitoring System I and Product Warranty in the industry. Superior system reliability and aesthetics ' . 4 all ; SunPower° X20-32■7-C-AC Residential AC Module Series k a A aml= Output @ 240 V (min./nom./max.) SPR-XL0-327-C-AC Nominal Power3(Pnom) 327 W Power Tolerance +5/-0% Avg. Panel Efficiency' 20.4% Temp. Coef. (Power) -0.2996/° C Shade Tolerance Three bypass diodes Integrated module -level maximum power point tracking k a A CHECKED BY: JAA Output @ 240 V (min./nom./max.) 211/240/264V Output @ 208 V (min./nom./max.) 183/208/229 V Operating Frequency (min./nom./max.) 59.3/60.0/60.5 Hz Output Power Factor (min.) 0.99 AC Max. Continuous Output Current @ 240 V 1.33 A AC Max. Continuous Output Current @ 208 V 1.54A , AC Mai. Cont. Output Power 320 W DC/AC CEC Conversion Efficiency 96.0% Max. Units Per 20 A Branch Circuit @ 240 V 12 (single phase) Max. Units Per 20 A Branch Circuit @ 208 V 10 (two pole) No active phase balancing for 3 phase CUSTOMER NAME: JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 buckshogohn50@gmaii.com installations ' . k a A CHECKED BY: JAA Solar Cells 96 Monocrystalline Maxeon Gen III . Front Glass High -transmission tempered glass with 'Temp. anti -reflective coating Environmental Rating Outdoor rated Frame Class 1 black anodized (highest AAMA Impact Resistance rating) Weight 45.5 Ibs (20.6 kg) Max. Recommended Module Spacing 1.3 in. (33 mm) k a A Warranties ' 25 -year limited power warranty 25 -year limited product warranty UL listed to UL 1741, including: IEEE1547/1547a and IEEE1547.1/1547.1a Utility Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV Modules (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(A) - (E)(1) FCC and ICE5-003 Class B When used with InvisiMount racking (UL 2703) Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free E2 1107-1046mm Em 1 1a1.21n] �I n.z Int 'Highest of over 3.200 silicon solar panels. Photon Module Surveyy. Feb. 2014 • - .F I rank in "PV Module Durability Initiative Public Report." Fraunhofer CSE, Feb 2013. Five out of • the top eight largest manufacturers were tested. Campeau, Z. et al. "SurlPmver Module I 1 sss mm Degradation Rate'SunPmrewhile paper, Feb 2013. See www.sunpcv.er.com/fans for details. i 161.3m] �I s u n p o w e r. c o m r'Standard Test Conditions (10DO Vd1W irradlance, AM 1.5, 25'C). 14REL calibration standard: SODS current LACCS FF and voltage. All DC voltage is fully contained within the module. 'Based on average of measured power values during production. ' Please read the safety and installation Instructions for details. See www.s0opowercom1acts for more refeienrnInformauor'—'---�'"'—' I y l For more details, see extended datasheet w"i.sunpower.com/clatasheets, i Documeni r, 515218 Rev D /LTR US :. 19 u1 '• •• • - (fin. S U N POW E.RCR by Hooked on Solar ASSESORS PARCEL #: 000-000-000 AR L ACHEb' O.00AC SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: ' 4.58 kW AC MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 180• AZIMUTH: 270° INSTALL TYPE: COMP SP LEASE # 1067829 SIGNED BY: DRAWN BY: AGN CHECKED BY: JAA Operating Temp. -40• F to +185° F (-40• C to +85• Q - Max. Ambient 122° F (50° Q 'Temp. Max. Load Wind: 62 psf, 3000 Pa, 305 kg/m2 front & back : Snow: 125 psf, 6000 Pa, 611 kg/M2 front Impact Resistance 1 inch (25 mm) diameter hail at 52 mph (23 n1/s) Warranties ' 25 -year limited power warranty 25 -year limited product warranty UL listed to UL 1741, including: IEEE1547/1547a and IEEE1547.1/1547.1a Utility Interactive PV Rapid Shutdown Equipment Equipment Grounding UL 6703, UL 9703 Connectors and cables (load break disconnection) UL 1703 PV Modules (Type 2 fire rating) Certifications Enables installation in accordance with: NEC 690.6 NEC 690.12 Rapid Shutdown (inside and outside the array) NEC 690.15 AC Connectors, 690.33(A) - (E)(1) FCC and ICE5-003 Class B When used with InvisiMount racking (UL 2703) Integrated grounding and bonding Class A fire rated PID Test Potential -induced degradation free E2 1107-1046mm Em 1 1a1.21n] �I n.z Int 'Highest of over 3.200 silicon solar panels. Photon Module Surveyy. Feb. 2014 • - .F I rank in "PV Module Durability Initiative Public Report." Fraunhofer CSE, Feb 2013. Five out of • the top eight largest manufacturers were tested. Campeau, Z. et al. "SurlPmver Module I 1 sss mm Degradation Rate'SunPmrewhile paper, Feb 2013. See www.sunpcv.er.com/fans for details. i 161.3m] �I s u n p o w e r. c o m r'Standard Test Conditions (10DO Vd1W irradlance, AM 1.5, 25'C). 14REL calibration standard: SODS current LACCS FF and voltage. All DC voltage is fully contained within the module. 'Based on average of measured power values during production. ' Please read the safety and installation Instructions for details. See www.s0opowercom1acts for more refeienrnInformauor'—'---�'"'—' I y l For more details, see extended datasheet w"i.sunpower.com/clatasheets, i Documeni r, 515218 Rev D /LTR US :. 19 u1 '• •• • - (fin. S U N POW E.RCR by Hooked on Solar ASSESORS PARCEL #: 000-000-000 AR L ACHEb' O.00AC SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: ' 4.58 kW AC MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 180• AZIMUTH: 270° INSTALL TYPE: COMP SP LEASE # 1067829 SIGNED BY: DRAWN BY: AGN CHECKED BY: JAA DESCRIPTION DATE REV CUSTOMER NAME: JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 buckshogohn50@gmaii.com SHEET TITLE: MODULE SPECS - PROJECT M 1814 SAMPLE SHEET #: 5.0 DATE: 5/11/17 -? e - SunPower° InvisiMountTM Residential Mounting System Simple and Fast Installation Integrated module -to -rail grounding ! Pre -assembled mid and end clamps Levitating mid clamp for easy placement Mid clamp width facilitates even module spacing I Simple, pre -drilled rail splice I UL 2703 Listed integrated grounding , i I Flexible Design i I Addresses nearly all sloped residential roofs Design in landscape and portrait Rails enable easy obstacle management Customer -Preferred Aesthetics #1 module and #1 mounting aesthetics Best -in -class system aesthetics Premium, low -profile design Black anodized components Hidden mid clamps and end clamps hardware, and capped, flush rails Part of Superioi System Built for use with SunPower DC and AC modules Best -in -class system reliability and aesthetics Combine with SunPower modules and monitoring app Elegant Simplicity SunPower® InvisiMountTM' is a SunPower-designed rail -based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster i installation time, design flexibility, and superior aesthetics. The InvisiMount product was specifically envisioned and engineered to pair with SunPower modules. The resulting i system -level approach will amplify the aesthetic and installation benefits for both homeowners and installers. sunpower.com .uL S 10 W Me SunPower° InvisiMountTM � Residential Mounting System uisl oun o ponen ages Module* / Mid Clamp and Rail Module* / End Clamp and Rail Mid Clamp End Clamp Rail & Rail Splice Ground Lug Assembly End Cap Y L •oo ;/�-Hoff. - Qfko 0 0 o D3. Component Material Weight Mid Clamp Black oxide stainless steel AISI 304 63 g (2.2 oz) End Clamp Black anodized aluminum alloy 6063-T6 110 g (3.88 oz) Rail Black anodized aluminum alloy 6005-T6 830 g/m (9 oz/ft) Rail Splice Aluminum alloy 6005-T5 830 g/m (9 oz/ft) Ul UUt id Lug Assembly and rtainlpss (A2-70 bolt; tin-plated copper log) 106.5 g/m (3.75 oz) End Cap Black acetal (POM) copolymer 10.4 g (0.37 oz) •oo ;/�-Hoff. - Temperature -40° C to 90° C (-40° F to 194° F) Composition Shingle Rafter Attachment Application Composition Shingle Roof Decking Attachment U6 27na I imrarl • Curved and Flat Tile Roof Attachment Class A fire rating when distance beween • Universal Interface for Other Roof Attachments •mm GitIIr o - - Refer to roof attachment hardware manufacturer's documentation *Module frame that is compatible with the InvisiMount system required for hardware Interoperabllity. 0 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INw51MOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. Specifications Included In this datasheet are subject to change without notice. sunpoweccom Document #509506 Rev B ISUMPOo n1�MER SUNPOWER9 by Hooked on Solar SSESORS PARCEL #: 000.000.000 PARCEL ACRES: O.00AC SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58 kW AC MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18° AZIMUTH: 270° INSTALL TYPE: COMP SP LEASE # 1067829 SIGNED BY: I A4�11e_ DRAWN BY: AGN Temperature -40° C to 90° C (-40° F to 194° F) Max. Load 2400 Pa uplift 5400 Pa downforce •mm GitIIr o - - Refer to roof attachment hardware manufacturer's documentation *Module frame that is compatible with the InvisiMount system required for hardware Interoperabllity. 0 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INw51MOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. Specifications Included In this datasheet are subject to change without notice. sunpoweccom Document #509506 Rev B ISUMPOo n1�MER SUNPOWER9 by Hooked on Solar SSESORS PARCEL #: 000.000.000 PARCEL ACRES: O.00AC SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58 kW AC MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18° AZIMUTH: 270° INSTALL TYPE: COMP SP LEASE # 1067829 SIGNED BY: I A4�11e_ DRAWN BY: AGN Warranties 25 -year product warranty DATE 5 -year finish warranty U6 27na I imrarl Certifications Class A fire rating when distance beween roof surface and bottom of SunPower module frame is s 3.5" •mm GitIIr o - - Refer to roof attachment hardware manufacturer's documentation *Module frame that is compatible with the InvisiMount system required for hardware Interoperabllity. 0 2015 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and INw51MOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. Specifications Included In this datasheet are subject to change without notice. sunpoweccom Document #509506 Rev B ISUMPOo n1�MER SUNPOWER9 by Hooked on Solar SSESORS PARCEL #: 000.000.000 PARCEL ACRES: O.00AC SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58 kW AC MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18° AZIMUTH: 270° INSTALL TYPE: COMP SP LEASE # 1067829 SIGNED BY: I A4�11e_ DRAWN BY: AGN CHECKED BY: JAA DESCRIPTION DATE REV CUSTOMER NAME: JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 buckshotjohn50@gmail.com SHEET TITLE: RACKING SPECS PROJECT M 1814 SAMPLE SHEET #: 6.0 DATE: 5/11/17 U 1 ; ✓ I "141C tngin( fit`and'd I M Vancouver, wA98661 Phone: 366-844-0048 'MD&LwWw.sunmodo.com WNM WAI.Odmi, '14 errat6d L F66't alldws'f& Versatile aluminum base for Fl"hi rail,mountiK' g o n`,-&itfi6r f r�wtions. multiple configurations.. ',w , r: ate side. 7T 74 T ,7 �4. The NexfGeneration,} in FlAshed Mounts for Shingle Roofs! nf%r- C, a 6 C cf. I "141C tngin( fit`and'd I 3ig66djo redirect Ez UU for Shingle Roofs Kit* KI0068-7'001 All kits come complete with the following parts: 1'-49130RSS5/i6X4 Pani B15015-002 :,I -'AI Shoe ParLN A20065401 1- Ez L Foot I CPQ Part# A2006"01 I -'Flashling, 1 -,Hex cap -:I'- Bo It 3/8 - 16 x 3/4" Part# A20052-001 Part# A20066-001 Nut Flange 3/8* Also avaffAble: I SUN(%= wwwsunmodo.com M Vancouver, wA98661 Phone: 366-844-0048 'MD&LwWw.sunmodo.com WNM WAI.Odmi, '14 errat6d L F66't alldws'f& Versatile aluminum base for Fl"hi rail,mountiK' g o n`,-&itfi6r f r�wtions. multiple configurations.. ',w , r: ate side. 3ig66djo redirect Ez UU for Shingle Roofs Kit* KI0068-7'001 All kits come complete with the following parts: 1'-49130RSS5/i6X4 Pani B15015-002 :,I -'AI Shoe ParLN A20065401 1- Ez L Foot I CPQ Part# A2006"01 I -'Flashling, 1 -,Hex cap -:I'- Bo It 3/8 - 16 x 3/4" Part# A20052-001 Part# A20066-001 Nut Flange 3/8* Also avaffAble: I SUN(%= wwwsunmodo.com M Vancouver, wA98661 Phone: 366-844-0048 'MD&LwWw.sunmodo.com WNM WAI.Odmi, 1905 - E 5th St. Ste. A Vancover, .WA 98661 Phone: 360 8440048 3.0 Grounding Overview - Warning! Ensure that you fully understand the grounding aspects in this section before proceeding. This section is.intended to provide a well-rounded understanding of all aspects of grounding for SunPower 96 -Cell AC Modules when they are installed with the SunPower® InvisiMounVm Residential Mounting System; it contains excerpts from the SunPower 96-Cell'AC Module Design and Installation Guide (#515791; unreleased); and.the SunPower AC Module Safety and Installation Instructions (#51744); as well as references to the applicable NEC Articles and UL Standards. The InvisiMount system is Listed to UL 2703 for integrated grounding; SunPower AC Modules are a bonding component and are Listed to UL 1741. If you are installing SunPower AC Modules on the InvisiMount system, no additional grounding hardware, lugs, or copper wire are required on the roof. sunp6.vv ' Invis M-ouriiT l + AC- Modlulid Glround,Achievem�r t- - Trans'cable 9 DATE REV Trans box House ground Array P �I 610 L -foot Rail Splice Splice Mid End screw clamp clamp AC Module - IS_U N PV�/ E,MR9' Nov. 2015 PROJECT M 1814 SAMPLE SHEET M 8.0 DATE: 5/11/17 _ r , J If you are,installing SunPower AC Modules on the SunPower InvisiMountTA° mounting system (or any mounting system that is Listed to UL 2703 for bonding—not just for fire classification), no additional grounding wire is required: The SunPower AC Module is one of the components that bonds all of the metallic non-current carrying components in the system, and is Listed to UL 1741. • As part of UL 2703, only AC equipment grounding requirements apply -not DC system grounding requirements nor DC equipment grounding requirements. The equipment grounding conductor (EGC) that's built into the module's AC cable system is sized appropriately and meets all of the AC equipment grounding requirements for the•system. • The AC dedicated branch circuit wiring from the readily accessible disconnect to the array must include an equipment grounding conductor (EGC) in the same raceway or cable as the AC circuit conductors. This EGC must be connected to the green conductor of the transition cable, which is part of the AC module cable system. If, a module is removed from a circuit, you must install a temporary EGC to bridge the gap by inserting an AC extension cable or other means, in order to maintain effective ground continuity to subsequent modules. • Because the modules are connected in a "daisy chain" fashion, disconnecting one module from the circuit using the AC cable removes voltage and ground from the other downstream modules in the circuit. Extreme care should be taken to ensure that no other energized sources are adjacent to these ungrounded modules, otherwise auxiliary grounding methods must be applied. io Because the DC power is internal to the module, a grounding electrode conductor (GEC) for the module or array is not required. The existing AC GEC at the utility service serves as the NEC -required GEC for the structure. • The AC cable grounding path has been tested by a NRTL, and its electrical continuity from the AC cable ground pin to the module frame has been certified. • The AC moduleinterconnecting cable system provides an internal EGC for grounding the AC modules. It is the installer's responsibility to ground any metallic mounting structure according to local code: Installers must ensure that whichever mounting system they choose is then grounded according to the instructions of that mounting system. Some mounting systems can be.bonded to the AC modules with listed devices. Consult the module's included safety instructions for details. • Neither the AC modules nor the array require a GEC, and the neutral conductor within the AC module is isolated from ground. The AC module must be connected to a dedicated AC branch circuit with the neutral conductor referenced at the building service entrance. • The AC interconnecting cable system attached to each module's microinverter is fully insulated and includes an internal EGC.-The grounding pin is longer than the others in the plug. a Document#515791 RevA - 24 SunPower Proprietary .Document#515791 RevA 25 SunPower Proprietary SUNPOWERG by Hooked on Solar ASSESORS PARCEL #: 000-000-000 PARCEL ACRES: O.00AC SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58 kW AC MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18° AZIMUTH: 270° INSTALL TYPE: COMP SP LEASE # 1067829 SIGNED BY: DRAWN BY: AGN CHECKED BY: JAA DESCRIPTION. DATE REV CUSTOMER NAME: JOHN SAMPLE 1678 GRACE ROAD GRIDLEY, CA 95948 530-434-1697 buckshotjohn50@gmaii.com SHEET TITLE: GROUNDING METHOD PROJECT M 1814 SAMPLE SHEET M 8.0 DATE: 5/11/17 1 S IMa=111 Re uitermants B'. S *. g q WARNING PHOTOVOLTAIC POWER SOURCE WARNINGI ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE - ENERGIZED. • • • • 690.12 COMPLIANT I/r1►\ T D 0 • 1 COMPLIES WITH NEC 690 12 � MODULE LEVEL RAPID SHUTDOWN I' WARNING; ------------- - ELECTRIC SHOCK HAZARD: DO NOT TOUCH TERMINALS. TERMINALS ON BOTH LINE AND 'LOAD SIDES MAY. BE ENERGIZED IN r THE OPEN POSITION: t WARNING. ELECTRIC SHOCK HAZARD ' THE DC CONDUCTORS OF THIS. PHOTOVOLTAIC SYSTEM ARE rt""'�+•�� I UNGROUNDED AND MAYBE ENERGIZED. - PH' 0TOVOLLTAIC NERGIZED.-PHOTOVOLTAIC - - - DCtDISCONNECTI I - - - PHO_ TOVOLTAIC WARNING INVERTER OUTPUT CONNECTION RATED MAX POWER -POINT CURRENT SYSTEM, METER DO NOT RELOCATE THIS ® OVERCURRENT PROTECTION RATEDMAxPOWER-POINTVOLTAG�, f DEVICE- _ MAXIMUM SYSTEM VOLTAGE — SHORT CIRCUIT CURRENT . . _ • _ --- —_ - - WARNING DUAL POWER SOURCE I ; POWER IS BEING SUPPLIED TO THIS PHO 1TVOO L_TAI C , PANEL' FROM THE UTILITY AND V SOLAR PV SYSTEM. THE SOLAR PV __ •' .--_ QAC DISCONNECT -- DISCONNECT IS LOCATED Locailon description or map here WARNING; - — ELECTRICSHOCKHAZARD NOMINAL AC VOLTAGE: IFA GROUND FAULT IS INDICATED, N NORMALLY GROUNDED CONDUCTORS RATED AC OUTPUT CURRENT. PHOTOVOLTAIC MAYBE UNGROUNDED AND ENERGIZED " WARNING DUAL POWER SOURCE 'AC' DISCONNECT. SECOND SOURCE IS PV SYSTEM WARN I N G NOMINAL AC VOLTAGE: • - ELECTRICAL SHOCK HAZARD. RATED AC OUTPUT CURRENr. '-- -- '- - - - - i -— II IIV'Y( )VV FKBI NEC 690.31(E)(3),(4) Wiring Methods, Direct -Current Photovoltaic Source and Output Circuits Inside a Building, Marking or Labeling Required Marking or Labeling Required.The following wiring methods and enclosures that contain PV power source conductors shall be marked with the wording "Photovoltaic Power Source" by means of permanently affixed labels or other approved permanent marking: 1. Exposed raceway, cable trays and other wiring methods . 2. Covers or enclosures of pull boxes and junction boxes 3. Conduit bodies in which any of the available conduit openings are unused The labels or markings shall be visible after installation. Photovoltaic power circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings or floors. Spacing between labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft.). Labels required by this section shall be suitable for the environment where they are installed. ®I IBTS INTERPRETATION: This code is specific to DC circuits to be identified as a Photovoltaic Power Source. This includes DC conduit, Junction Boxes, and Combiner Boxes that are inside or connected to the building structure. NEC 69035(F) Ungrounded Photovoltaic Power Systems The photovoltaic power source shall be labeled with the following warning at each junction box, combiner box, disconnect and device where energized, ungrounded circuits may be exposed during service: WARNING ELECTRIC SHOCK HAZARD THE DC CONDUCTORS . .sarfd0l m.pKca9w�^ NEC 690.S(C) Ground Fault Protection, Labels and Markings A warning label shall appear on the utility -interactive inverter or be applied by the installer near the ground -fault indicator at a visible location, stating the following: WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY 4 BE UNGROUNDED AND ENERGIZED When the photovoltaic system also has batteries, the same warning shall also be applied by the installer in a visible location at the batteries. ®Y IBTS INTERPRETATION: A warning label shall be applied to the Inverter or near the I ground fault indicator describing the hazard that would exist in the event of a ground fault. NEC 690.14(c)(2) Additional Provisions Requirements for Disconnecting Means, Markings Each photovoltaic system disconnecting means shall be permanently marked to identify it as a photovoltaic system disconnect IBTS INTERPRETATION: Required at any disconnecting means including AC II Disconnect, DC Disconnect, and Main Service Panel. Also required at Inverters with integrated disconnects and subpanels. This label should be applied directly to the component and does not apply to the"line of sight"provision. The DC or AC reference is not specifically required. P Y OF THE PHOTOVOLTAIC SYSTEM ARE NEC 705.12 (D)(4) Point of Connection, Utility -Interactive Inverters, UNGROUNDED AND MAY BE ENERGIZED. Markings ®I IBTS INTERPRETATION: This label should be installed for Ungrounded Photovoltaic Equipment containing overcurrent devices in circuits supplying power to a busbar or Systems on DC components where ungrounded circuits may be exposed during conductor supplied from multiple sources shall be marked to indicate the presence of service.This includes thejunction box, combiner box, DC disconnect, and Inverter. all sources. IBTS INTERPRETATION: This label is required on the main service panel to Identify that the panel is energized from multiple sources, the Utility and a NEC 690.17 Switch or Circuit Breaker �I Photovoltaic system. Label is also required on subpanels, fused AC disconnects, SP LEASE # 1067829 The disconnecting means for ungrounded conductors shall consist of manually operable or any other component housing an overcurrent protective device. , switch(es) or circuit breakers(s) complying with all of the following requirement: 1. Located where readily accessible 705.12(D)(7) Point of Connection, Inverter Output Connection 2. Externally operable without exposing the operator to contact with live parts Unless the panelboard is rated not less than the sum of the ampere ratings of all 3. Plainly indicating whether in the open or closed position over -current devices supplying it, a connection In a panelboard shall be positioned at the SIGNED BY: 4. Having an interrupting rating sufficient for the nominal circuit voltage and the current that is available at the line terminals of the equipment Where all terminals of the disconnecting means may be energized in the open position, a warning sign shall be mounted on or adjacent to the disconnecting means. The sign shall be clearly legible and have the following words or equivalent: WARNING e - - ELECTRIC SHOCK HAZARD. DO NOTTOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES . . MAY BE ENERGIZED IN THE OPEN POSITION. Exception: A connector shall be permitted to be used as an AC or a DC disconnecting means, provided that it complies with the requirements of 690.33 and is listed and identifiedfor the use. IBTS INTERPRETATION: This label should be installed on the covers of the . disconnecting means that may be energized in the open position. This includes combiner boxes, DC disconnects and inverters with integrated DC disconnects. Should be installed on grounded and ungrounded systems. by Hooked on Solar SSESORS PARCEL #: 000-000-000 PARCEL ACRES: e O.00AC SMALL-SCALE, SINGLE-PHASE PV SYSTEM SIZE: 4.58 kW AC MODULES: (16) SPR -X20 -327 -C -AC CIRCUITS: CIRCUIT #1 ACPV IN SERIES = 12 CIRCUIT #2 ACPV IN SERIES = 4 TILT: 18o AZIMUTH: 270' INSTALL TYPE: COMP NEC 690.53 Direct -Current Photovoltaic Power Source A permanent label for the direct -current photovoltaic power source indicating items 1 through 5 shall be provided by the installer at the photovoltaic disconnecting means: 1. Rated maximum power -point current 2. Rated maximum power -point voltage 3. Maximum system voltage Informational Note to 3.: See 690.7 (A) for maximum photovoltaic system voltage. 4. Short-circuit current Informational Note to 4.: See 690.8 (A) for calculation of maximum circuit current. S. Maximum rated output current of the charge controller (if installed) Informational Note: Reflecting systems used for irradiance enhancement may result in Increased levels ofoutput current and power. DISCLAIMERIBTS INTERPRETATION: This code reference describes the label content to be ®I present at any DC disconnecting means of a system. If applicable, this includes The purpose of this graphic is to provide a reference guide to solar photovoltaic system labeling requirements in accordance with the Inverters with an integrated DC disconnect. 2011 National Electric Code (NEC), National Fire Protection Association (Copyright 2010), as interpreted by the Institute for Building -- Technology and Safety (tBTS). Users should always follow the code requirements and interpretations for specific placement of labels of = the presiding Authority Having Jurisdiction (AHJ). NFPA 706, National Electrical Code• and NEC° are registered trademarks of the National Fire Protection Association, Quincy, MA. opposite (load) end from the input feeder location or main circuit location. The bus or conductor rating shall be sized for the loads connected in accordance with Article 220. In systems with panelboards connected in series, the rating of the first overcurrent device directly connected to the output of a utility -interactive inverter(s) shall be used in the calculations for all busbars and conductors. A permanent warning label shall be applied to the distribution equipment with the following or equivalent wording: WARNING INVERTER OUTPUT CONNECTION _ DO NOT RELOCATE THIS OVERCURRENT DEVICE ®IBTS INTERPRETATION: This label must be used when the sum of the Photovoltaic system breaker/fuse and Main Service Panel breaker/fuse is greater than 100% of the busbar rating. It is not required if the sum of those two breakers supplying the busbar is equal to or less than the busbar is rated for. • Example A: 200A maximum rating on busbar. 200A main breaker+20A back fed PV breaker = label required • Example B: 220A maximum rating on busbar. 200A main breaker+20A back fed PV breaker = no label required. NEC 690.56(8) Facilities with Utility Services and PV Systems Buildings or structures with both utility service and a photovoltaic system shall have a permanent plaque or directory providing the location of the service disconnecting means and the photovoltaic system disconnecting means if not located in the same location. ®I IBTS INTERPRETATION: All system disconnects on a Utility -Interactive PV System, are required to have this label identifying where other system disconnecting means are located if not visible from either component. Reprinted with permission from NFPA 70•- 2014, National Ereadcocade, Copyright 07013, National Fire Protection Association, Quincy, MA This reprinted material is not the complete and official position of the NFPA on the referenced subject which is represented only by the standard In Its entirety. ® CONTACT Q CONNECT www.ibts.org facebook/IBTSsolar Chris Doyle I Program Director - Solar @IBTS solar cdoyle@ibts.org 512.452.8899, — IBTS - Solar PV ® IBTSorg m Institute for Building Technology and Safety; 2014 " Institute for BUllding Technologyand Safety, 3074 ' DRAWN BY: _ AGN ; CHECKED BY: JAA DESCRIPTION DATE REV CUSTOMER NAME: JOHN SAMPLE 1678 GRACE ROAD .. GRIDLEY, CA 95948 530-434-1697 buckshotjohn50@gmail.com SHEET TITLE: SAFETY LABELS PROJECT #: 1814 SAMPLE SHEET #: 9.0 DATE: 5/11/17 Butte County Department of Development Services FORM NO PERMIT CENTER 7 County Center Drive, Oroville, CA 95965 DBI -01 arss.r,aewax Main Phone (530) 538-7601 Fax (530) 538-7785 %www.buttecountv.net/dds Declaration of Installation for Smoke Alarms and Carbon Monoxide Alarms The newly adopted 2013 California Residential Code requires the installation of Carbon Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. The policy for Carbon Monoxide Alarms in Butte County states: "Any permit obtained in which the value of work exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the following 2013 California Residential Code requirements for Smoke and Carbon Monoxide Alarms (Section R314 & R315)." 2013 California Residential Code requirements for Carbon Monoxide Alarms: R315.1 New construction: An approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. R315.1.2 Power supply: For new construction required carbon monoxide alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery back-up. Alarm wiring shall be directly connected to the permanent building wiring without a disconnecting switch other than as required for over - current protection. Exceptions: 1. In dwelling units where there is no commercial power supply the carbon monoxide alarm may be solely battery operated. 2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space. R315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit. a Exception: . . 1. Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes, there is no access by means of attic, basement or crawl space, and no previous method for interconnection existed. R315.2 Where required in existing dwellings: Where a permit is required for alterations, repairs or additions exceeding one thousand dollars,($ 1;000), existing dwellings or sleeping units that have attached garages or fuel -burning appliances shall be provided with a carbon monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained. R315.2.6 Alarm"requirements: No person shall install, market, distribute, offer for sale or sell any carbon monoxide device in the State of California unless the device and instructions have been approved and listed by the State Fire Marshal. Pagel of 2 Revised 7.20.2015 Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2. On every level of a dwelling unit including basements. R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2013 CRC, Sections 314 &-315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached arages or fuel -burning appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms. DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, I/we affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that I/we will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will also be installed prior to final inspection as per the 2010 CRC. il Smoke and Carbon Monoxide alarms are now installed in the following locations: Owner's name (print): Owner's signature: Contractor's name (print): Contractor's signature: Project Address: Page 2 of 2 Revised 7.20.2015 Permit #: 6 V