Loading...
HomeMy WebLinkAbout018-010-043BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES INSPECTION CARD•MUST BE ON JOB SITE 24 Hour Inspection Line (IVR) : 530.538.4365 (Cut off time for inspections is 3pm). Development Services cannot guarantee inspections on the date requested Office: 530.538.7601 Fax: 530 Permit No: B17-1242 Issued: 6/20/2017 APN: 018-010-043 Address: 81 CHICO CANYON RD, CHICO Owner: • BONETTI DAVID & SARA ROSE Permit Type: SOLAR ROOF -RES Description: • Installation of roof mountedsolar4.2 KW Asa. i ia� www.tiutteuounty.nevam AREA 4 Flood Zone: None SRA Area: No .9F.TRACKS for 7nn*nvr- AG_ SRA_ PW Front: Centerline of Road: Rear: SRA: Street: AG: Interior Total Setback from Centerline,of Road: ' ALL PLAN REVISIONS MUST BE APPROVED BY THE COUNTY BEFORE PROCEEDING Ins ection e INSINSP DATE Setbacks 131 Foundations./ Footings 111 Pier/Column Footings 122 Eufer Ground 216 Masonry Grout 120- 20-Do 131 Pool Plumbing Test DoNot Pour Concrete Until Above are Sign d Pre -Slab 124 Gas Test Underground/floor 404 Gas Piping Underground/floor 403 Underfloor Framing 149 Underfloor Ducts 319 Shear Transfer 136 Under Floor Plumbing 412 Under. Slab Plumbing 411 612 Tiedown/Soft Set System' 611 Permanent Foundation System Do Not Install Floor Sheathing or Slab Until Above Signed ShearwallB.W.P.-Interior 134 Shearwall/B.W.P.-Exterior 135 Roof Nail/Drag Trusses 129 605 Continuity Test Do Not Install Siding//Stucco or Roofing Until Above Signed Rough FraminE 153 - Rough Plumbing 406 Rough Mechanical 316 Rough Electrical •208 4 -Way Rough Framing 128 Gas Piping House. .403 Gas Test House 404 Shower Pan/Tub Test 408 ' Do Not Insulate Until Above Signed Permit Final. 802 Electrical Final 803 Mechanical Final 809 Plumbing Final 813 Fire Sprinkler, Test or Final 702 Swimmin? Pools Setbacks Inspection Type IVR INSP DATE T -Bar Ceiling 145 Stucco Lath 142 Swimmin? Pools Setbacks 131 Pool Plumbing Test 504 Gas Test 404 Pre-Gunite 506 Pre -Deck 505 Pool Fencing/Alarms/Barriers 503 Pre -Plaster 507 Manufactured Homes Setbacks '131 ' Blockin nder inin 612 Tiedown/Soft Set System' 611 Permanent Foundation System 613 Underground Electric 218 Sewer - 407 Underground Water 417 Manometer Test 605 Continuity Test 602 Ski rting/Steps/Landings 610 Coach :Info Manufactures Name: Date of Manufacture: Model Name/Number: Serial Numbers: Length x Width: Insignia: Public Works Final 538.7681 Fire De artment/CDF 538.6226 Env. Health Final 538.7281 Sewer District Final F_ -PROJECT FI L f *Project Final is a Certificate of Occupancy for (Residential Only) PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE. IF WORK HAS COMMENCED._ YOU MAY PAY FOR A 1 YEAR RENEWAL 30 DAYS PRIOR TO EXPIRATION ` Butte County Department of Development Services PERMIT CENTER 7 County Center Drive, Oroville, CA 95965 �'" '•"" ~'• Main Phone (530) 538-7601 Fax (530) 538-7785 www.buttecounty.net/dds Declaration of Installation W for Smoke Alarms and Carbon Monoxide Alarms FORM NO DBI -01 The newly adopted 2013 California Residential Code requires the installation of Carbon Monoxide Detectors in dwelling units and in sleeping units within which fuel -burning appliances. are installed and in dwelling units that have attached garages. The policy for Carbon Monoxide Alarms in Butte County states: "Any permit obtained in which the value of work exceeds $1000 associated with a Residential Group R Dwelling Unit or Sleeping Unit shall conform to the following 2013 California Residential Code requirements for Smoke and Carbon Monoxide Alarms (Section R314 & R315)." 2013 California Residential Code requirements for Carbon Monoxide Alarms: R315.1 New construction: An approved carbon monoxide alarm shall be installed in dwelling units and in sleeping units within which fuel -burning appliances are installed and in dwelling units that have attached garages. R315.1.2 Power supply: For new construction required carbon monoxide alarms shall receive their primary power from the building wiring where such wiring is served from a commercial source and shall be equipped with a battery back-up. Alarm wiring shall be directly connected to the permanent building wiring without a disconnecting switch other than as required for over - current protection. Exceptions: I , I . In dwelling units where there is no commercial power supply the carbon monoxide alarm may be solely battery operated. 2. In existing dwelling units a carbon monoxide alarm is permitted to be solely battery operated where repairs or alterations do not result in the removal of wall and ceiling finishes or there is no access by means of attic, basement or crawl space R315.1.3 Interconnection. Where more than one carbon monoxide alarm is required to be installed within the dwelling unit or within a sleeping unit the alarm shall be interconnected in a manner that activation of one alarm shall activate all of the alarms in the individual unit. Exception: 1. Interconnection is not required in existing dwelling units where repairs do not result in the removal of wall and ceiling finishes there is no access by means of attic basement or crawl •� space, and no previous method for interconnection existed R315.2 Where required in existing dwellings: Where a.permit is required for alterations, repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping units that have attached garages or fuel -burning appliances shall be provided with a carbon monoxide alarm in accordance with Section R315.1. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping'unit for, which the permit was obtained. R315.2.6 Alarm requirements: No person shall install, market, distribute, offer for sale or sell any carbon monoxide device in the State of California unless the device and instructions have been approved and listed by the State Fire Marshal. Page 1 of 2 Carbon monoxide alarms required by Sections R315.1 and R315.2 shall be installed in the following locations: 1. Outside of each separate dwelling unit sleeping area in the immediate vicinity of the bedroom(s). 2. On every level of a dwelling unit including basements. R315.1.5 Multiple -purpose alarms: Carbon monoxide alarms combined with smoke alarms shall comply with Section R315, all applicable standards, and requirements for listing and approval by the Office of the State Fire Marshal, for smoke alarms. Butte County's Interpretation of 2013 CRC, Sections 314 & 315 for Smoke Alarms & Carbon Monoxide Alarms: Where alterations, repairs or additions exceeding $1,000 in valuation, existing dwellings shall be retrofitted with smoke alarms and those that have attached garages or fuel -burning_ appliances shall have carbon monoxide alarms installed. Existing smoke alarms can be replaced with dual function alarms for Smoke and Carbon Monoxide and in most cases will comply with the aforementioned code requirements for Carbon Monoxide Alarms. ,` DECLARATION OF INSTALLATION UNDER THE PENALTY OF PERJURY As Owner/Contractor, l/we affirm and declare under the penalty of perjury, under the laws of the State of California, by our signatures below as Owner/Contractor, that I/we will comply prior to final inspection with Items A & B as specified herein: A. Both Owner/Contractor have read and clearly understand the aforementioned 2010 California Residential Code (CRC) Carbon Monoxide Alarm requirements. B. Both Owner/Contractor are responsible for installing Carbon Monoxide Alarms prior to final inspection as per the aforementioned building code and maintaining such installation. Smoke Alarms will also be installed prior to final inspection as.per the 2010 ., CRC. Smoke and Carbon Monoxide alarms are now installed in the following locations: ' nrTi tiros ��u L�E691 1E) h- -- 0&1 E•ti4 Li 1, 51orGw2KiG 3ay-to t r' ,silL�^.IL`' I �Ac1t SL +�� ►� P.cowt A.at) OVT`IMt - N -6S AIA kZg5 ('u i 6" tE:U&r_ 1 S�l< 4_u 'D i ktCj (print):�i�'(Q 9 p o..t� t�a�rrnc S Owner's name Owner s signature: Date: Contractor's name (print): ti �� CSLB license: Contractor's signature: Date: (� Z Project Address:'i\ Ci MO(II) on R6. (` h\Q1 b Permit #: 12>1—+" I'D q2 Page 2 of 2 �O'' PV SOLAR SYSTEM SPECIFICATIONS: u m SYSTEM SIZE - 4.200KW DC/ 3.450KW AC w BONETTI RESIDENCE MODULE TYPE & AMOUNT - (15) JINKO SOLAR JKM280M-60B 2Nm N zmm MODULE DIMENSIONS - (L/W/H) 64.97in/ 39.06in/ 1.57in ooz $1 CHICO CANYON RD INVERTER - (15) ENPHASE 10.26-60-2-US UUU C�J (� Q (��] H I V O CA J JL H "INVERTER(S) USED IN THIS DESIGN IS/ARE COMPLIANT WITH CEC 201.690.12 (RAPID SHUTDOWN). SEE MANUFACTURER DATA SHEET. Z ° Q INTERCONNECTION METHOD - LOAD BREAKER O L m GOVERNING CODES SHEETINDEX: ' ALL WORN SHALL CONFORM TO THE FOLLOWING CODES f{F • 2016 CALIFORNIA BUILDING CODE PV 0.0 - COVER SHEET "� `� T'• • 2016 CALIFORNIA ENERGY CODE PV 1.0 - SITE PLAN • 2016 CALIFORNIA ELECTRICAL CODE PV 2.0 - MOUNTING DETAIL 2016 CALIFORNIA FIRE CODE E 1.0 - 3-LINE DIAGRAM x. �i �, • 2016 CALIFORNIA GREEN CODE E 2.0 - NOTES a At�5-v�3r1 2016 CALIFORNIA MECHANICAL CODE E 3.0 - WARNING LABELS 2016 CALIFORNIA PLUMBING CODE E 4.0 - WARNING LABELS CONT. �� e 2016 CALIFORNIA RESIDENTIAL CODE •E 5.0 - ELECTRICAL PHOTOS ` ANY OTHER LOCAL AMENDMENTS E 5.1 - ELECTRICAL PHOTOS CONT. - N_ fit - •R . •. .. . L^ - + a F' � :. 0: a • — " .- m SHEET NAME: 2 F— + a' 3� �' +a r W W y� +i y J��ry 1. r NOTES: > 111 O = A PHOTOVOLTAIC MOUNTING RACK INSPECTION MAY BE REQUIRED PRIOR TO PANEL INSTALLATIONS. w ANY MODIFICATIONS TO THE EXISTING ROOF AND/OR PLUMBING DRAIN, WASTE, AND/OR VENTS AR TO COMPLY WITH THE 2016 SHEET CBC/CPC NUMBER: - . ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS - THE BACKFEED BREAKER SHALL NOT BE MARKED FOR "LINE" AND "LOAD" MARKINGS - CONDUIT RUN THROUGH THE ATTIC OR UNDER EAVES DENOTED WITH DASHED LINES ON SITE PLAN SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED, PURSUANT TO SECTIONS R314 AND R 315 OF THE CRC WIND SPEED: 11OMPH SNOW LOAD: OPSF CATEGORY:C 16 RAFTER DIMSPACING: V RAFTER SPACING: 108" O Z I C, _ZN& /� V/ 0 DI UOD _ Ooul OZ TT7 PV SYSTEM SIZE: Roof Section 1 > s r w Rod Aim - 315 Q 4.200 kW DC Rod GLE Z Roof Typo: ROLLED ❑ O J PV SYSTEM SIZE: 00 ; ....... 3.450 kW AC O o Oo o .... <. .:: »;> CIRCUIT KEY: ®PV CIRCUITri1 O O O O 15 MODULES L.o _ E -.TING SYSTEM O [' /p t I I �/ O EXISTING PV SYSTEM SIZE: 8.580 KV OC O ^ (33) EXISTINGJINKO SOLAR JKA1280P'80MODUIE$ INT" O (331EXISTING ENPHASE N215iA2LLS22JG O n a MICROIN\cR1ERS l7 MOUNTED OIJ THE BACK OF EACH MODULE I I $ KEYNOTES LEGEND a 80' OF 1' EMT CONDUIT RUN FROM x �' JUNCTION BOX TO ELEC PANEL I I MOUNTED NO MORE THAN 3112' AND g n N NO LESS THAN 112' ABOVE THE ROOFeq JUNCTION BOX ATTACHED TO ARRAY m m USING ECOFASTEN HARDWARE TO Z o3 KEEP JUNCTION BOX OFF ROOF 15 NEW JINKO SOLAR JKM280A1.60B PV - Z MODULES WITH AN ENPHASE I w w m 106 -60 -2 -US MICH014NVERTER MOUNTED ON THE BACK OF EACH I r Q MODULE z Z o UTILITY METER 9 100973535 • PV SHEETrml ' INTERCONNECTION POINT I NAME:' Q NEW PHOTOVOLTAIC AC DISCONNECT 1 A/C LOCA'T'ED WI'T'HIN 10' OF MSP I - " i - I � J ©NEW DEDICATED PHOTOVOLTAIC . ' SYSTEM COMBINER PANEL r _ SHEET • 1 NUMBER: 81 CHICO CANYON RD, CHICO, CA 95928 PV SYSTEM SITE PLAN 38' SAFETY OFFSET FOR ROOF Access FRONT OF HOUSE iSCALE•3/32" = T-0" a S116' FLANGE NUI 300 SERIES SS ROCK-IT SLIDE ROCK-IT COUPLING 5/16' ID EPDM BONDED WASHER MIDCLAMP Lijm c 300 SERIES SS ROCK-ITCOUPLING L) (� �+ MID CLAMP Z EPDM BONDED WASHER ROCK-IT SLIDE FORMS WATERTIGHT SEAL Q (r_* ROOFING WATERPROOF puO1iw (n MASTIC ROCK-!? COUPLING SHELF ® Z w GREENFASTEN BUSHING VUj 0 \ 00, i COMPRESSION PLATE _O UUO UPPER LEVEL MASTICW R CK-IT '0 U a DF-1(4) TIE PLATE 5/16'A7112" COUPLING SHELF Z 5116-A3' SCREW (4) 5116'x3' HEX FLANGE BOLT O SCREW SIDE VIEW 300 SERIES SS m H 7 ISOMETRIC VIEW SIMPLEGRIP BASE CD—ROOF LEVEL MASTIC 1 SIMPLEGRIP MOUNT 3 ROCK-IT COUPLING ASSEMBLY REBFODRSGREWBINTDRDOFPER NOT TO SCALE PV 2.O �NOTE: MOUNIING FOOT. TWO OF THE FOUR SCREWS NEED TO BE PLUNGED INTO THE RAFTER 180° NOT TO SCALE PV 2.O TOP VIEW 1' FROM ONE ANOTHER. _N LEVER L/3 OR LESS CLAMP + ATTACHMENT CLAMP +AITACHMEN7 PERMITTED COUPLING COUPLING CLAMP SPACING am= `� o =NAX 48' (4' 1 1 1 1 1 1 1 1 1 1 1 I J 3 COUPLING CLAMP I) I I 1 I i I I RAFTER MODULE ROCK-IT MODULE iv PV 2.0 COUPLING ± o I I I � MODULE I I $ rn ®RAFTER I I RAFTER L=LANDSCAPE CLAMP SPACING N tii ROCK4T SLIDE Z m PEDESTAL ^ PV SYSTEM MOUNTING DETAIL OMODULES IN PORTRAMLANDSCAPEPORTRAR j Z PV 2.0 NOT 10-1 py 2.0 xo110 5u1E CLAMP SPACING � m r J J m 5/16SOLT . 3' MIN AND W MAX BETWEEN TOP OF ROOF AND BOTTOM OF MODULE HEX FLANGE BOLT 2 2 300 SERIES BS 1 CONDUIT o PV MODULE, TT'P. MOUNT PV 2.0 TO FRAMING Of EXISTING ROOF TYPE, PARALLEL - 6" MA�PiIIFI1R OF ROOF CONDUIT ELEVATED MIN 1' ABOVE ROOF SHEET NAME: ~ J Z Q II I cOc G Q SHEET NUMBER: 2 SIDE VIEW - �� / \PV ARRAY TYP. ELEVATION MOUNTING DETAIL NOT TO SCALE PV 3.0 NDT1D�E �CONDUIf ; Pv 2.0 Pv z.O uOnOsule CL. _ Photovoltaic System Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) DC System Size (Watts) 4200 Tag # Description Wire Gauge 0 of Conductors/Color Conduit Type Conduit Size rn z AC System Size (Watts) 3450 1 Enphase Engage Cable THWN-2 12 AWG 3(Ll, L2, G) N/A -Free Air N/A -Free Air 0 odule/Inverter Count 15 1 Bare Copper Ground(EGC/GEC) 6 AWG 1 BARE N/A -Free Air N/A -Free Air v o Z N m ch 2THWN-2 lOAWG 2(1L11L2)B/R EMT 3/4" o t z � Jh 2THWN-2-Ground 8AWG v c Lg WEC Z o 4 V o u rp U U p?� Existing Module l nforma tion: Type:JKM260P-E0 count: 33 7 if Existing PV Combiner Panel (alsting inverter Information: Type: M215-60-2LL-522-IG • count: 33 0 C VISIBLE LOCKABLE 'KNfF A/C • ti ISCON DSCONNECT " squarel) • •�'� - DU222RB - 'o - 240V/60M1240V UNFUSED NEMA3 io a U on n d a U � ad � a u _ O 0 N W Zm U) - - 20A Rapid Shutdown Poi nto I lerconnecti on, Load Z m Disconnect, Square D Sid 7 5.121D11211311b), Z • 20A DU221RB, 240W30A, Co ms to CEC 2016 m SA Unfused, NEMA3, or to N equivalent el ezN Z Z 20A SHEET • Inverter: Enphase 10660 -2 -US - M New 240V/225A Service NAME: 1 "Envoy -S Panel, Single Phase, with • Q\� ODA 20UA Main Disconnect .c 'P 40A to O SHEET 2 , 2 0A PV Ci rcuit L IS 2 \ m mer ane-S48A/240V NUMBER: 'Modules/ 1 CONTINUOUS, PROTECTION MAX 60A4 Parallel ON COMBINER OUTPUT NEMA4 Junction Box with Irreversible Visi c Knife A/C Minimum GEC size 2 " Ground Splice JYP) Disconnect AWG copper W SOLAR MODULE Enphase 1. - 1Qti-60-2-US MICRO -INVERTER AT —� CA011 MODULE. i,TTA0i ICD WITH ECOLIBRIUM SOLAR HARDWARE F6 BARE CU GROUND (ATTACHED TO FIRST MODULE IN ARRAY). BALANCE OF ARRAY GROUNDING CONNECTIONS V MADE THROUGH ARRAY HARDWARE MICROINVERTER CONNECTION TO ENGAGE TRUNK CABLE ' Inverter Make/Model IQ6-60-2-US Max. Dc Volt Rating 48 Volts Max. Power at 40 C 230 Watts Nominal AC Voltage 240 Volts Max- AC Current 0.96 Amps Max. OCPD Rating 20 Amps Max. Panels/Circuit - 16 15 Short Circuit Current 15 Am s Inverter Make/Model M215 -60 -2U_ -S22 -IG Max. Dc Volt Rating 45 Volts Max. Power at 40 C 215 Watts Nominal AC Voltage 240 Volts Max. AC Current 0.9 Amps Max. OCPD Rating 20 Amps Max. Panels/Circuit 17 15 Short Circuit Current 15 Amps Other Notes PV Module Rating @ STC 14.4 Module Make/Model 1KM28OM-608 240 Max. Power -Point Current (Imp) 8.81 Amps Max. Power -Point Voltage (Vmp) 31.8 Volts Open -Circuit Voltage (Voc) 38.6 Volts Short -Circuit Current (Isc) 9.S3 Amps MdA. Set ies rUSe (OLVU) 15 Aifips Nom. Max. Power at STC (Pmax) 280 Watts Max. System Voltage 1000 V DC (UL) Voc Temperature Coefficient -0.29 %/C AC Output Current According to NEC 690.8(B)(1) 14.4 1Amps Nominal AC Voltage 240 1Volts THIS PANEL IS FED BY MULTIPLE SOURCES UTILITY AND SOLAR) Rooftop conductor ampacities designed in compliance with NEC 690.8, Tables 310.15(B)(2)(a), 330.15(8)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9. Loacation specific temperature obtained from ASHRAE 2013 data tables. ASHRAE2013- Highest Monthly 2% D.B. Design Temp.: 38.7 °C Lowest Min. Mean Extreme D.B.: -3.8'C PV Module Rating @ STC Module Make/Model 1KM26OP-60 Max. Power -Point Current (Imp) 8.37 Amps Max. Power -Point Voltage (Vmp) 31.1 Volts Open -Circuit Voltage (Voc) 38.1 volts Short -Circuit Current (Isc) 8.98 Amps Max. Series Fuse (OCPD) 15 Amps Nom. Max. Power at STC (Pmax) 260 Watts Max. System Voltage 1000 V DC (IEC) Voc Temperature Coefficient -0.31 %/C • Utility Service Provided by PGE • No battery back-ups are tied to the designed inverter(s). • Inverter(s) used in this design is/are compliant with CEC 2016 690.12 (Rapid Shutdown). See manufacturer data sheet. • Array grounding and bonding designed in compliance with CEC 2016 690.47(C)(3).. • Design calculations compliant with CEC 2016. • All ampacity calculations are made in compliance with NEC 220.5(B)..49 and below is rounded down to 0, and .50 and above are rounded up. - - Conductor Calculations - Wire gauge calculated from NEC code 310.15(B)(16) with ambient temperature calculations from NEC 330.15(2)(a). For "On Roof' conductors we use the 90°C column ampacity, 0.5"-3.5" off -the -roof temperature adjustment from 310.15(B)(3)(c), and raceway fill adjustments from 310.15(B)(16). For "Off Roor' conductors. we use the 75°C column amoacity. or the 90'C column ampacitV with the relevant ambient temperature and raceway fill adjustments, whichever is less. The rating of the conductor after adjustments MUST be greater than, or equal to, the continuous duty uprated output current. Calculation Example - Wire Rating (90°C) x Ambient Temperature Adjustment x Conduit Fill Adjustment >= Continuous Duty Output Current (On Roof, Tag 2): 10 gauge wire rated for 40 A, 40 A x 0.65 x '1 (2 Conductors) = 26A- 18A OCPD Calculations Breakers sized according to continuous duty output current. PV circuit nominal current based off N of modules per Circuit X (1.25(NEC code 210.19(A)(1)(a) X (0.96 Max AC current per micro - inverter) Circuit 01 = 15 modules, Output Current w/ continuous duty = 18 < 20A Breaker system output current w/ continuous duty = 18 < 20A (System OCPD) NUMBER: N W Inverter Grounded Systems Per 690.5jC) Main Service Panel Signage WARNING(installed on the Face of the Service Meter) 0 ELECTRICAL SHOCK HAZARDPer •'r •'r 705.10 IF A GROUND FAULT IS INDICATED,Note: Roofline placard not needed unless PV disconnect is not at the NORMALLY GROUNDED CONDUCTORSsame - MAY BE UNGROUNDED AND ENERGIZED CAUTION: SOLAR•ELECTRICAL SYSTEM CONNECTED Combiner Boxes, J -Boxes, Disconnects, ■ C�IUTION: Inverters In Systems Per •'r POWER TO THIS BUILDING IS ALSO S4PBLIED FROM`T�:1E Un -Grounded FOLLOWING SOURC �1NftH DISCOP(, ETS LOCAT QAS ELECTRICAL SHOCK HAZARD �� , `V �',,' `V THE DC CONDUCTORS OF THIS \ '•_' '�Nr�TEI��ND firl(i�'N SE_ jiVECE PHOTOVOLTAIC SYSTEM ARE UNGROUNDED !.� -- �� � QAC IfiCO�@CT c`��r( ' � AND MAY BE ENERGIZED '�� D,��:�pz('�,CONNECT�\ --- • WARNING: PHOTOVOLTAIC POWER SOURCE DisconnectAC WARNING: DUAL POWER SOURCE Per 690.17(E) 705.12 SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM HAI ■ • ..- • • • DISCONNECT m v v RATED AC • • OPERATING • • • i V DC Disconnect Per 690.17 WARNING v u ELECTRICAL SHOCK■ • • NOT TOUCHON BOTH THE LINE AND LOAD SIDES MAY BE ELECTRICAL SHOCK HAZARD ENERGIZED IN THE OPEN POSITION •• NOT TOUCH• +. m o o u BOTH THE LINE AND LOAD SIDES MAY BE • •• •• • s m Inverter Output Connection (Solar Breaker) at o • Main Service Panel Per 705.12 WARNING INVERTER OUTPUT CONNECTION ■ • NOT RELOCATE .. OVERCURRENT DEVICE ' • * �,�, n • r Rapid Shutdown Per 690.56)C) , t, Rapid Shutdown Disconnect Per 690.12(5) Installed On AC Disconnect , ., - • - - z z S PHOTOVOLTAIC • ■ • ■ • • • • " .. SHEET RAPIDWITH • • !. - 8" ' . r ;' � NAME:_ • ` v Tr! =vl: ".i' F, i ,-a is _ ! s a �,i r ? -• y T .4 , ,y:: " ` i x;y ,.a e'., . • ,h" f•.. .. r .�' r _ " a F 3- lt'• t ,. - L' J�... '-■w. - J l .. ' . k t t SHEET y , f - •,,.. .-.. • .. ,� • _ • ,. • _ t .. .,r w .' r ._- ,;jr r •4 ':� .. NUMBER: . ALL STICKERS DESCRIBED HERIN SHALL BE MADE OF WEATHERPROOF ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO • ' •, ? aw a M SMALLER THAN 3/8" WHITE ARIAL FONT TEXT AND HAVE A RED BACKGROUND UNLESS OTHERWISE DEPICTED OR DESCRIBED. , ' ; , J ui ASI ' • J , ' - . ` y ^ ._.. • .. , - . 1 CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED /1 WARNING: DUAL POWER SOURCE (] WARNING WARNING 1 4 9 12 q+ Property of Vivint Solar SECOND SOURCE IS A PHOTOVOLTAIC SYSTEM ELECTRICAL SHOCK HAZARD ELECTRICAL SHOCK HAZARD "• RATED AC OUTPUT CURRENT: "• A IF o 0 MAIN BREAKER DE -RATED TO DUE TO SOLAR A GROUND FAULT IS INDICATED, THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE CIRCUITS NOM. OPERATING AC VOLTAGE: •"• V NORMALLY GROUNDED CONDUCTORS UNGROUNDED AND MAY BE ENERGIZED 2 "'AMPS O O MAX OF PV SOURCE ALLOWED Property of Vivint Solar MAY BE UNGROUNDED AND ENERGIZED Property of Vivint Solar DO NOT INCREASE MAIN BREAKER RATING WARNING: PHOTOVOLTAIC POWER SOURCE Property of Vivint Solar q SITE PLAN PLACARD SHOWING ADDITIONAL POWER Property Vivint Solar 1� z S S E of Prnpprty of l/ivint Snlar+�f/'� WlaONING SOURCE A140 DISCOIJNCCf LOCA11urvS. FLAL,AKU �f �J 1 0 u u a WARNING PHOTOVOLTAIC AC DISCONNECT INVERTER OUTPUT CONNECTION SHALL BE MOUNTED ON EXTERIOR OF ELECTRICAL m° 3 ELECTRICAL SHOCK HAZARD RATED AC OUTPUT CURRENT: — A DO NOT RELOCATE THIS OVERCURRENT DEVICE PANEL (only when necessary) 6 °p t --' DO NOT TOUCH TERMINALS. TERMINALS ON BOTH NOM. OPERATING AC VOLTAGE: ••' V Property of Vivint Solar Property of Vivint Solar THE LINE AND LOAD SIDES MAY BE ENERGIZED IN -'' Property of Vivint Solar PHOTOVOLTAIC POWER SOURCE DC DISCONNECT 11 THE OPEN POSITION PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID RATED MAXIMUM POWER POINT CURRENT (IMP) ••• A14 PV rapid shutdown disconnect Property of Vivint Solar 7 SHUTDOWN RATED MAXIMUM POWER POINT VOLTAGE (VMP) " V�. placard indicated on E.3 Property of Vivint Solar MAXIMUM SYSTEM VOLTAGE (VOC) "• V t� g PHOTOVOLTAIC DC DISCONNECT SHORT CIRCUIT CURRENT (ISC) '•'A (� ` Property of Vivint Solar Properly of Vivint Solar 0 • '• • - value calculated for each N account, for specific value see the - label previous warning page v 11 14 4 7 v ROOFTOP ARRAY 8 12 6 6 6 2 4 13 IF APPLICABLE EVERY 10' AND o _ WITHIN V OF v ELBOWS ;yo�90 3 9 3 3 3 1 1 2 5 5 5 5 5 5 o _ � 5 o`.s�`Zo!_ 0 �''/, C� z W ul MICRO-INVERTERO :� 9 O O z m SYSTEMS DC w w z 9 DISCONNECT INSIDE z z S JOB) `---..-------._ - - -_---- SOLAR INVERTERS COMBINER PANEL VISIBLE/LOCKABLE VIVINT SOLAR METER VISIBLE/LOCKABLE SUB PANEL MAIN SERVICE SHEET NAME: c 12 JUNCTION (MAY BE ON ROOFTOP (WHEN USED) A/C DISCONNECT (WHERE REQUIRED) A/C DISCONNECT WHEN REQUIRED) DISCONNECT PANEL REQUIRED) STRING -INVERTER BOX INTEGRATED WITH (WHERE 10 10 v, d ARRAY) TYPICAL SOLAR GENERATION INSTALLATION INSIDE PANEL m a m SYSTEMS _ (NOT ALL DEVICES ARE REQUIRED IN EVERY JURISDICTION) SHEET NUMBER: ALL STICKERS DESCRIBED HERIN SHALL BE MADE OF WEATHERPROOF THESE PLACARDS SHALL BE PLACED ON ALL INTERIOR AND EXTERIOR DIRECT-CURRENT (DC) CONDUIT, ENCLOSURES, RACE -WAYS, CABLE ADHESIVE, THEY SHALL BE REFLECTIVE, THEY SHALL CONTAIN NO ASSEMBLIES, JUNCTION BOXES COMBINER BOXES, AND DISCONNECTS TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKINGS SMALLER THAN 3/8" WHITE ARIAL FONT TEXT, AND HAVE A RED SHALL BE PLACED ON ALL DC CONDUIT EVERY 10 FT (3048 MM), WITHIN 1 FT (305MM) OF TURNS OR BENDS AND WITHIN 1 FT (305 MM), ABOV E It BACKGROUND, UNLESS OTHERWISE DEPICTED OR DESCRIBED. AND BELOW PENETRATIONS OF ROFF/CEILING ASSEMBLIES, WALLS OR BARRIERS ui E 5.0 'M ELEC. R, g T-4 PHOTOS 5507299 a 6 mint. solar BONETTI RESIDENCE 81 CFO CO CANYON RD CHICO, CA 95928 UTILITY ACCOUNT NUMBER: 9672499908-1 �1 F " ( P' i � mrd f •�. �e' ell 4t4 r 'i Pte:--+r 'i � t .l'r°• � r r � jet- �,I�1;, rt' 'g"�T'�ttr`d �r7 "'1 yam•• • �tf '. .. rG •""'�'Pt.}S F,'S3.�4 111 r ,1_1. .tA�py`i.�iQ1i:l '�lr- i. Ire __ T.. { �� � i• �� i cN - ni INSTALLER:VIVINTSOLAR ■ r --- BONETTI RESIDENCE E 5.1 mm ELEC. mm INSTALLER NUMBER: 1.877.404.4129 �■�y'� Q�y.�M A PHOTOS • M ` solar 81 CHICO CANYON RD .. CHI CO. CA 95928 DRAWN BY: JC S: 5507299 I Last Modlad: 6114/2017 UTILITY ACCOUNT NUMBER: 9672499908.9 www:jinkosolar:Com i i + •/ rPreliminary •_ Version T � r i KEY FEATURES High Efficiency .� H:nh module etriciency r.rp [O '17 7291. ,viii? ?assiv,nied lmi:lec Rehr Contact 1PERC1 t�r.,hnnlogy ! til High Voltage Law •, 4 - 1000V standard- 1500V option lowers SOS cosi and Yields bPtror LCOE t r ' Innovative Solar Cells roux busbar cell -.ethnology mproveS module efr}cien(7.y + •.j. PID -Free + j ? r •Walld',s 1st PIU-Fnie module at 85C 854mRH " .r ( Low -Light Performance 0, Advanced glass anti solar cell Curfl, ce texturing allow for. extoll Erni. ' .pq iva6m performance in low -light environnien1% 444; Strength and Durability 1 Withstands Snow (54001:,a) Mutt wind '0400Pi) loads. salt misi and ammonia • LINEAR PERFORMANCE WARRANTY .. - 10 Year Product warranty 2S Year Linear Power Warranty100� - • '� ` �L • ® linear Performance wauanry s q7% Ad tanoant r perounance warran(y : rflrip c us rr.......:e CE 9sri 1 , of �a/pp frpm _ LISTED � gar, Jrnk °fOlar'rr • Illy c i . Years" .err, � * rs• p .r' — � r• ..z,. - - ' CurraN•VokoycS Power-Vakaye Curves (79evvl ., " In'l)'i) III)I) lli.�( »f • � _, .i II }�-• � v _ - - r.,;'`�' Te perahim Npan1-- of Isr..Vna p— L' . 1 , ' . iMechanicaliCharacteristics .v - .�. • I ��} Cell Type Mono -crystalline PERC 156 +156mm (6 inch) 'I Nn,ef cells 60(('.10) e Dimensions 1650s992x40mm 04.97,3906x 1 57 inch) � Weight ^i 19,0 kg (41.9 lbs) r '. V rX ' 1 A, - Front Glass 3 limn, High Transmission. Low. Iron, ' AR Coating TemprJeci Glass , - r Packagings Configurations Frame Anor'ited Aluminium alloy 1 T.A4 r )unctiun Box I?67 Rated r 25pcsj box,-50pcs/pallet 700 pcs!40'4q Container Output Cniaes '2AWG, ! ength: IOOOmm i3) 3'- inch) - - .. '>s• �7 Fire Type • + Type 1 ` � t - . ! :SPECIFICATIONS 111! i 0 Modulc Type :` • JKM270W508 JKM275M.608 ,JKNINOM-606 JKR•1295M-608 JKM290M-608 , STC NOCT STC NOCT STC NOCT STC VOLT r STC NOCT Maximum Power (Prrtax) _ w 270Wp 201 WP 275Wp 205Wp 280Wp 209Wp 2351Np 212WP 2901.1vp 21 GWP Maximum Pourer Voltage (Vmp) 31.4V 29.3V 31.6V 29.6V 31,8V 29.7V 32.OV 29.9V 32.2V 30.2Vs $ Maximum Power Current (Imp) y 8.60.A 6.85A 9.70A 6.93A 8.81A 7.0 1 4 6.90A 7.12A 9.02A 7.21A r - r - Open -circuit Voltage (Voc) 38.AV 35.6V 38.5V 36.0V 38.6V 36.2V 38.7V 36AV 38.8V 36.8V - +:j•_,•Shr;rt-circuit Current(Isr-) 1 - 9.28A 7.45A 9,40A 7.54A 953A 7.62A 9.65A 7.72A. 0.78A 7.81A _ kt , Module Ef'16ency STC (9a)'• ' %` 16.50% 16.80% 17.11% 1?•41% 17.72% - I E ' Operating Tent eraturc 'C' Maximum system voltage 100Ov0C(Uy • Maximum series fuse rating cr 15A r Power tolerance Tempemtuie coefficients of Pmax 0 "Temperature coefficients of Voc e : 0.29°:d'C r L to e Temperature coefficients of Iso 1 Nominal operating cell temperature (NOCT) 45±2 C i STS `�,wlrradldnce 1000W/m2 '` .0 -col Temperature 25'C ' + Atvl=1.5 N6et. ,J lrradiance 8004M/m'Ambient Temperature 20'C 40' AM= 1.5 Wind Speed 1m/s Power merstnement tolerance: ± 34'0 CAUTION READ SAFETY AND INSTALLATION INSTRUCTIONS 3EF6R= USING rHE PRODUCT : Jinkr, Solar Co._ Lul. All rights reser: ecl specilicatiotls i111"i0cied in IM4, tlalasheet are subiect m change without nolice. ti US-MiC'I'-290M-ti0B-v_rsv2016 L' . 1 Enphase IQ 6 and IQ 6+ Microinverters U� To learn more about Enphase offerings, visit enphase.com U Designed for higher powered modules, the smart grid - ready Enphase IQ 6 Micro'" and Enphase IQ 6+ Micro' are built on the sixth -generation platform and achieve the highest efficiency for module -level power electronics and reduced cost per watt. Part of the Enphase IQ System, the IQ 6 and IQ 6+ Micro integrate seamlessly with the Enphase IQ Envoy"', Enphase IQ Battery'", and the Enphase Enlighten'" monitoring and analysis software. The IQ 6 and IQ 6+ Micro are very reliable as they have fewer parts and undergo over 1 million hours of testing. Enphase provides an industry-leading warranty of up to 25 years. Easy to Install Lightweight Simple cable management Built-in rapid shutdown (NEC 2014) Productive Optimized for high powered modules Supports 60 and 72 -cell modules Maximizes energy production Smart Grid Ready Complies with fixed power factor, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles n ENPHASE. Enphase IQ 6 and IQ 6+ Microinverters INPUT DATA (DC) IQ6-60-2-US AND I06 -60.5 -US IQ6PLUS-72-2-US AND IQ6PLUS-72-5-US Commonly used module pairings' 195 W - 330 W + 235 W - 400 IN + Llouule civnpatibiliiy 60-ce11 PV mcdules only bu-cell and /2 -cell I -'V modules Maximum input Ilr7 voltage 48V 62V Peek power tracking voltage 77 V - 37 V 27 V - 45 V Operating range 16 V - 48 V 16 V - 62 V Min/Max start voltage 22 V i 48 V 22 V / 62 V Max DC short circuit current (module Iscl 15 A 15A overvoltage class DC port 11 DC port hickferrl under singie fault 0 A n A NV array configuration 'I x I ungrounded array; No additional UC side protection required; This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC -2014 and AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQG-60-2-US AND IQ6-G0-5-US IQ6PLUS-72-2-US AND IQGPLU3-72-5-US Pcok nrrtput pnwr r �— 24f1 VA _-- -•- -- __-_ _._ —..�_ 29n VA Maximum continuous output power 230 VA 280 VA Nominal voltage/rangez 240 V It 211-264 V 208 V (lm) i 183-229 V 240 V 1211-264 V 208 V (I (D) 1183-229 V Nominal output current 0.96 A 1 11 A 1 17 A 1 35 A Nominal frequency 60 Hz 60 Hz Fxtendad frP.giranry range 47 - 6:11-17 47 - 6A H- Power factor at rated power 1.0 1 0 Maximum writs per 20 A branch circuit 16 (240 VAC) 13 (240 VAC) '14 (5iriyle-plid5r. 208 VAC) 11 ,.shiyle-t,h?,rse 2.08 VAC) Overvoitage class AC port I11 III AC port backfeed under single fault 0 A 0 A Power factor (adjustable) 0.7 leading . 0.7 lagging 0.7 leading •. 0.7 lagging EFFICIENCY @240 V (x)208 V (10) @240 V (x208 V (10) CEC taeighte.d efficiency 97.0% 96.5% 97.0% 96.5 °i, MECHANICAL DATA Ambient temperature range -40°C to +65°C Relative humidity range 49; to 100% (condensing) Connector type MC4 or Amphenol H4 UTX Dimensions (WxHxD) 219 mm x 191 mm x 37.9 nun (without bracket) Weight 1.4 kg (�.3 lbs) Cooling Natural convection - No fans Approved for wet locations Yes Pollution degree P03 Environmental category / UV exposure rating Outdoor - NEMA 250, type 6 (IP67) FEATURES Communication Power line Monitoring Enlighten Manager and MyEnlighten monitoring options Compatible with Enphase IQ Envoy Compliance UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class 8, ICES -0003 Class S. CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC -2014 and NEC -2017 section 69012 and C221-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. 1. Nc enforced OCrA.0 ratio, See the compatibility calculator at �lphase ram/en-us(;�p o err udulP-cumuatdlrljty. 2. Nominal voltage range can be extended beyond nominal if required by the utility. To learn more about Enphase offerings, visit enphase.com 20, % ci ase Ener., All r rt; e: l,II t ;,•: me. <s : bianrs user. are; ,•re D doe ;1 _rpnus 11 ,ergy, PIC E N P H AS E . 171 MoDEcoFasten Solae Committed to the connection Document date 3.6.2017 Contents Pg. 1 ....... :......... .. ................................Assets .... ,_ ....,....., .. ..._.... ...._... of Design Features System Components Pg. 2 . .. ............. ,..:... ....... Rock -It 2.0 Mount Assembly Rock -It 2.) Coupling Assembly pg. 3..................................................................... ........... Rock -It 2.0 Hykrid Mount Assembly Rocx-It Clip SS Assembly Pg. 4 ......... ................................................................. ,........... .... _............. ...................... I......yout Array La GreenFasten Flashing Install Pg. 5 ................ ... ....... ... Rock. -It System 2.0 Install Pg. 6 ... ........................... - Ground Lug Install Cock -It Clip SS Install Pg. 7 -11................................................................................................................ Standoff Spacing Tables Snow Load 0-20 psf Snow Load 21-30 psf Snow Load 31-40 psf Snow Load 41-50 psf Snow Load 51-60 psf Pg. 12.................................................................................................................... Grounding Information Bonding Assembly and Bonding Path Pg. 13.................................................................................................... Thermal Expansion and Bonding Bracket Spacing Staggered Layout Cantilever Pg. 14...................................................................................................... Evaluated, Compatible Modules System Specifications www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 Rocl-<-IT SYSTem 2.0 Designed with the installer in mind. EcoFasten Solar specializes in solar roof attachments that are fast and easy to install, straightforward, secure and cost-effective. EcoFasten offers a wide variety of standard products as well as custom solutions, for a one-stop sou rce for all of your rooftop anchoring needs. Products are rigorously tested and approved above and beyond industry standards in-house and by third party agencies. EcoFasten's patented conical sealing system has been in service in the snow guard and solar industries for two decades. FeaTures • Fastest, easiest to level system on the market • Conforms to UL 2703 First Edition • Class A Fire Rating with Type 1 modules • Integrated electrical bonding • SIMPLE- only 4 components • North-South adjustability • Only one tool required (1 /2" deep well socket) • Vertical adjustment of 3"-4" sysTem comPonenTs* - reouireD ROCK -IT SLIDe ROCK -IT 2.0 ROCK -IT 2.0 COUPLInG 4" For comp SHInGLe MOUnT & I-oaD BearinG FOOT 8" For TILe sysTem comPonenTs* - oPTIonaL ROCK -IT 2.0 HYBrID MOLInT (ReFer To PG. s) ROCK -IT CLIP SS (ReFer To PG. 6) ROCK -IT 2.0 Array SKIFT ,Q 4 -Eco aster Solar EcoFasten Solar products are protected by the following U.S. Patents: 8,151,522 8,153,700 8,181,398 19166,713 8,146,299 8,209,914 8,245,454 8,272,174 5225,557 9,010,038 9.134,040 9,175,478 9,212,833 *Components for use with 32mm modules are available as special order. Components for use with 32mm modLiles are labeled as such on packaging. Side profile of Mid -Clamps on Rock -It 2.0 Mount and Rock -It 2.0 Couplings is slightly different for use with 32mm modules. Please refer to evaluated, compatible modules on page 14. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 - i moi' ROCK -IT 2.0 MOUI'1T ASSeMBL9 NOTe: ITems 1-7 SHIP assemBLeD ITem 6 Pre-ToroueD 1 5/16"-18 Hex Flange Bolt (or Hex w/star washer) 300 Series SS 2 Rock -It Mid -Clamp 6000 Series AL (rtg. A: Mid -Clamp for use with 32mm modules) 3 Conical Spring 300 Series SS 4 Rock -It Shelf 2.0 6000 Series AL S Flange Level Nut 300 Series SS 6 Rock -It Pedestal 6000 Series AL 7 Rock -It -Te Plate 6000 Series AL 8 Rock -It -Slide -Tile 2.0 6000 Series AL (sola separately) 9 Rock -It -Slide -Comp 2.0 6000 Series AL (;old separately) i l l %ice 'i /.' ITeMS 8-9 are aCC2PTaBLe BracKeTS FOr use WITH THe 'I 'I, ! ROCK -IT 2.0 A' (SOLD SePara-eLY ) ROCK -IT 2.0 COUPLING aSSemBLy NnTP' ITPM:; 1-4 CHIP ;:�gcPMR1 Pr - 1 5/16"-18 x 1.25" or 1.5" Hex Flange Bol: 300 Series SS 2 Rock-It-Coupling-MidClamp 6000 Seri �s AL (fig. A: Mid -Clamp for use with 32mm mcdules) 3 Conical Spring 300 Series SS 4 Rock -It -Coupling -Shelf -2.0 6000 Series AL 5 Load Bearing Foot JL fig. A (32)mm) CJ www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 2 ROCK -IT 2.0 HYBRID MounT ASSeMBLY NOTe: ITems 1 -lo SHIP assemBLeD 1 5/16"-18 x 1.25" or 1.5" Hex Flange Bolt 300 Series SS 2 Rock-It-Coupling-MidClamp 6000 Ser,es AL (dig. A: Mid -Clamp for use with 32mm modules) 1 --,Z� 3 Rock -It -Coupling -Shelf -2.0 6000 Series AL 4 Crushable Spacer- Cardboard or Simaar �J(I' 5 Flange Level Nut 300 Series SS 6 Rock -It Pedestal 6000 Series AL 7 3/8" ID Star Washer 300 Series SS I � . ' 8 3/8"-16 x 3" Hex Tap Solt 300 Series S� 9 5/16"-18 x 3/8" Hex Serrated Flange Belt 300 Series SS ' 10 Rock -It Tie -Plate -T 6000 Series AL (32 M) r www.ecofastensolar.com (z), ROCK -IT CLIP ss A.ssem-BLY NOTe: ITems 1-3 SHIP aSseMBLeD 1 Stainless Steel Carriage Bolt -.313-18X.75 2 Rock -It Clip SS 3 Stainless Steel Flange nut .313-18 info@ecofastensolar.com 877-859-3947 3 Array LaY OUT Find the required structural attachment points. Mark these using a vertical (N -S) chalk line on the center of the rafters. Spacing may vary depending upon project specific structural requirements; Le. high snow and wind load areas may require lesser bracket spacing in the E -W axis vs. the maximum spacing. Max spacing is 48"for portrait orientation and 72"for landscape orientation. Consult project layout diagram for project specific bracket spacing on the roof. Install Rock -It Mounts to predetermined mount spacing. • The array skirt sections are the width of a typical 60 cell module — use the array skirt as a guide to lay out module placement. Note: The distance between the rows of mounts is calculated by the module dimension N-S.plus 1 3/8" (35mm). Lag screw should be installed as close to center of exposed shingle as possible. The minimum distance between the lag screw and the edge of the shingle is 1/2". GreenFasTen FLasHinG insTaLL position for each Green Fasten flashing. vertical lines to n—arkthe installation 2 Drill a pilot hole (1/4"diameter) for the lag bolt. Backfill with sealant. Eco Fasten Solar recommends an EPDM mastic. 3 Insert the flashing so the top part is under the next row of sFingles and pushed far enough up slope to prevent water infiltration through vertiol joint in shingles. The leading edge of flashing must butt against upper row of nail's to prevent turning when torqued. 4 Line up pilot hole with GreenFasten flashing hole. Insert the lag bolt through the EPDM bonded washer, the Rock -It slide, the gasketed hole in the flashing and into the rafter. Torque: The range is between 100-140 torque inch -pounds aepending on the type of wood and time of year. The visual indicator for proper torc'ue is when the EPDM on the underside of the bonded washer begins to push out the sides as the washer compresses. If using an impact wrench to install the fasteners be careful not to over torque the fastener. You may need to stop and use a ratchet o finish the install. 'The Engineer of Record shall check capacity of rafter to suppor- lag screw loading. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 ROCK -IT SCJ-STeI'1'1 Z.O inSTaLL J. Install Eco Fasten Solar Flashing with Rock -It Mounts Follow EcoFasten Solar l nsta(l instructions for flashing and bracket install (GreenFasten shown above) Optimum vertical distance between lag bolts is 13/8'plus module dimension - Set mounts on eave most row so that the Rock -It Pedestal is on the South end of Rock -it Slide Set mounts on all upper roves so that the Rock -it Pedestal is on the North end of Rock -It Slide 2 Install Array Skirt on Eave Mounts Loosen Hex Flange Bolt in Rock -It Mid -Clamp Slide Array Skirt Into front channel on Rock -It Shelf Tighten Hex Flange Bolt to engage the Array Skirt 3_5 Install Rock -It Couplings Snap Load Bearing Foot into the bottom of every Rock -It Coupling prior to mounting on the roof (Each Load Bearing Foot is set to same height as the Rock -It Mounts - adjust accordingly) On eave row only, slide Rock -It Skirt into front channel on Rock -It Coupling On eave row only, tighten the west most Array Skirt bolt on Coupling first to 150 in4bs., followed by tightening the east bolt, drawing the Array Skirt sections together Upon final levelling of entire array (see step 11), utilize the Levelling Nut to ensure that the Load Bearing Feet engage the roof surface NOTE: If a coupling lands on d rafter, the Hybrid Mount' should be used in place of the Rock -It Coupling (refer to image 3a) 'Hybrid Mount can be made in the field by assembling a coupling, o amount pedestal, or by purchasing separately Align and Straighten First Row of the Rock -It System with Array Skirt Use North-South adjustment of the Rock -It Pedestal to sualghcen array skirt Torque screw on side of Rock -It Pedestal to 150 in -lbs to secure it to tate Rock -It Slide Adjust Flange Level Nut to level the system (optional -can be leveled during or after installation) 7-10 Install 1st Row of PV Modules Slide upslope Rock -It Mounts down to engage top offirst module Install Rock -It Couplings on the upslope side of 1st row of panels Torque tstand 2nd row ofMid-Clamps on Rock -it Mounts and Rock -It Couplings to 150 in -lbs. (Torque to 130 in -lbs. when installing with 32mm modules) Install balance of PV modules, ensuring that the Rock -it Pedestals are In the appropriate position, then torque Mid -Clamps to secure modules Level the Rock -It System • When assembly is complete, level the entire system by adjusting Flange Level Nuts (Flange Level Nuts have no torque value) www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 s Ir' i GrounDlnG LUG InSTaLL T Necessary Components: - Burndy CL50-ITN Ground Lug (UL Listing NKDER.E9999) ' Note: Drill and deburr hole in Ground Lug prior tc installation - 14 AWG - 4 AWG Copper Ground Wire" - 8-32 x 0.5" Serrated Flange Head Bolt (300 Series SS - 8-32 Serrated Flange Nut (300 Series SS) - 11/32"and 1/4" wrenches or ratchets/sockets 1 Insert the flange bolt into the module ground hole. Place-5round Lug over the bolt and turn to desired orientation. 2 Install Flange Nut. 3 Tighten Flange Nut/Bolt. 4 Place wire in Ground Lug channel and tighten setscrew to complete assembly. Torque Values: 14-10 AWG= 20 in -lbs. 8 AWG= 25 in -lbs. 6-4 AWG= 35 in -lbs. `Minimum of 1/4" clearance required between bare copper wire and aluminum. ROCK -IT CLIP SS InSTaLL f ;.''tin ;icn �,mrt�r 9u'i 1 Locate all parts -Locate the Rock -It Clip SS, micro-inverter/power optimizer, and the section of the module frame in which you will be mounting the micro-inverter/power optimizer. See fig. A for acceptable mounting locations. 2 Install the Rock -It Clip SS • Slide the Rock -It Clip SS onto the lip of the module frame. • Slide the micro-inverter/power optimizer into the opposite lip of the Rock -It Clip SS. Tighten the bolt to 20 ft -Ib to clamp the Rock -It Clip SS to the module frame and the micro-inverter/oower optimizer to the Rock -It Clip SS. • Ensure that the lip on the clip is tight against the frame and that the micro-inverter/power optimizes flange is tight against the Clip flange to avoid rotation during tightening. www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 6 • r r �, ''., r' • y � �} ' 1 � �1 ���h + i ' r. �•• .. ' i ,. - fir• _ Snow Load 0-20�psf , fi - _ Modules in Landscape Wind Speed Exposure Category 2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 Zone 2 ..-•_s3_ Zone 3 Zone 1 --33= 8 159 93 59 '103' X103= 85 mph 110 mph C 114 67 42 03 __ 88 86 + T. 0 96 '56 35 91 _74 _ 74 �. 29 41 29 B 146 85 54 103ncmz03 90 mph 115 mph C 104. 61 38 98 80 80 33 20 53 0• 88 51 32 83 68 68 31 31 B 123 72 45 12 32 —18— '-46- 95• 95 100 mph 125 mph , C 88 51 32 83, 68 68 27 22 27 22 D 74 43 27 70 57 57 B 98 57 36 93 76 76 110 mph 140 mph C 70 41 26 66 54 54 v D 59 34 22 56 46 46 0' B 85 50 31 81' 66 66 120 mph ' 150 mph . C 61 36 22 58 t. 47 47 •D. 51 30 19 49 .40 40 . . `s Notes: + + ®Spacing Governed by Snow Load 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff. ,II t r however the designer must round down to meet appropriate rafter spacing + 2.) Maximum allowed spacing approved by EcoFasten Solar is 72" 3.) Maximum allowed standoff capcity, = 547# (per testing results) * 1 4.) Includes additional factor of safety of 1.5 for lag pullout capacity r 5.) Values based on a maximum module width of 40' - 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height " ` 7.) All adjustment factors are set to 1. No site specific engineering is included in this table - Snow Load 0-20 psf 4 t , Notes: + . ®Spacing Governed by Snow Load `.. •..,. ' - , 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Sclar standoff _ 2.) Maximum allowed spacing approved by EcoFasten Solar is 46" t 3.) Maximum allowed standoff capcily = 5474 (per testing results) ` +: • ' •4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5•) Values based on a maximum module length of 70" " 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height r, ' , 7.) All adjustment factors are set to 1. No site specific engineering is included in this table ' www.ecofastensolar.coml f' info@ecofastensolar.com 877-859-3947 _';'�; : 7 ^ • - a�Y:l• .,a` -• .-rr. t . L - +fit '' Wind Speed Exposure 2:12 < Roof Pitch < 6:12 1 7:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Cat o Zone 1 6 T—'91— f Zone 2 ..-•_s3_ Zone 3 Zone 1 --33= Zone 2 Zone 3 MW .+..-..� .... 85 mph •110 mph C 1 65 D 55 - B 83 38 L `32.. 4 9 24 61 " .. . 20 - d52 30— 50 42 50 42 .. ■ 46 46 90 mph' 115 mph . C 59 35 22 56 D 50 ,.r._„ B `��' "�,, 70'.� C 50 29 41 29 18 47 '�6 +18 47 38 39• 38 Rr--�'� 39 100 mph ..-.�...r•.._•. 125 mph D _ �42 B 56 26 _ _ 15 __..A0 X32—X32 43 _ _ 33 20 53 43 110 mph 140 mph } C 40 23 14 38 31 31 0 34 B • —r-49— 19 �... 28. "" 12 32 —18— '-46- 26 — 37 ..- 26 " 37" Li120 mph i 150 mph C ;35 •. 0 L-._29 201 t 1 17 i 12 33 10 s 28 27 22 27 22 Notes: + . ®Spacing Governed by Snow Load `.. •..,. ' - , 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Sclar standoff _ 2.) Maximum allowed spacing approved by EcoFasten Solar is 46" t 3.) Maximum allowed standoff capcily = 5474 (per testing results) ` +: • ' •4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5•) Values based on a maximum module length of 70" " 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height r, ' , 7.) All adjustment factors are set to 1. No site specific engineering is included in this table ' www.ecofastensolar.coml f' info@ecofastensolar.com 877-859-3947 _';'�; : 7 ^ • - a�Y:l• .,a` -• .-rr. t . L - +fit '' I . Modules in Landscape r Wind Speed Exposure 2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12 t Category Zone 1 . r Zonal • Zone Zone 3. fASCE -7-05� B 1'.0^ 93 N ~ i 85 mph.. S• 110 mph.. fib 85 niph a J C D • B fi .O 67 56 85 42 35 54 ,111 88 .6 B8 •��,: ` �...� # 0 .90 mph 115 mph C 104 61 38 68 I . Modules in Landscape r Wind Speed Exposure 2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zonal Zone 2 Zone Zone 3. fASCE -7-05� B 1'.0^ 93 59-68-7--68 i 85 mph.. S• 110 mph.. fib 85 niph a 110 mph C D • B fi .O 67 56 85 42 35 54 66 t"68 t 48 88 .6 B8 68 .96 # 0 .90 mph 115 mph C 104 61 38 68 69 . 68? ' J• t,. D B 88 51 72 32 45 Be fie.' 8B `.,....,ri.,'......� � 125'mph h p B C 100 mph 125 mph C 88 51 32 68 ; -if8-- - 0- 32 74 74 43 27 $B 57 57 23 14 38 31 B 98 5.7 36 8 19 rr28, 20 12 32 26 q.•..•.. ,�,...., --..._, 1S 37 12 ^ 33 27 66 54 54 110 mph 140 mph C 70 41 26 «• D 59 34 22 56 46 46 -� B 85 50 31 66 66 88 58 120 mph 150 mph C 61 36 22 47 47 D 51 30 19 49 40 40 Notes: spacing Governed by Snow Load r �, 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces onlyon doff. EcoFasten Solar stan a ' however the designer must round down to meet appropriate rafter spacing - 2.) Maximum allowed spacing approved by EcoFasten Solar is 7Z' • 3.) Maximum allowed standoff capcity = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity U 5.) Values based on a maximum module width of 40" 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feel in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table t 1 ' Snow Load 21-30 p sf ; f 1 77 Wind Speed Exposure Category 2:12 < Roof Pitch < 6.12 7:12 < Roof Pitch < 12:12 . • ASCE 7-10 Zone 1 Zone 2 53— Zone 3 Zone 1 Zone 2 ' Zone 3. fASCE -7-05� i 85 mph.. S• 110 mph.. - C 38r 24 "41 • 4'F t 1d 7 65 L. .L. =- - ; _„,D B 55 X32' 49 . x.20". 41 30 41' 41 41 40 • 59 90 mph .115 mph C 35 22 Al., i? 38 ....w.r..r•w. 100 mph lp D "-..... EO 29 '""„"41.,`.-' 29 18 q1; 138 '26� —4r4i 18- 39 `.,....,ri.,'......� � 125'mph h p B C � eo r1 39 D B 42 56 __26_ 33 40 • 32 32 20 +i 110 mph 140 mph C 40 - 23 14 38 31 31 �• rruir•� 120 mph' D- ....-:. .Y -s+.......- B' C 34 a 49 35 19 rr28, 20 12 32 26 q.•..•.. ,�,...., --..._, 1S 37 12 ^ 33 27 26 �. 37 ; 27 war+....-•. 150 mph • 29 17 ' 10: _ 28 22 22 _ Notes: pr r? Spacing Governed by Snow Load a , - 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standofl 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" .^ 3.) Maximum allowed standoff capcity = 547# (per testing results) ' R 4.) Includes additional factor of safety of 1.5 for lag pullout capacity ' 5.) Values based on a maximum module 16nglh of 70" ' 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height ' •rr , 7.) All adjustment factors are set to 1. No site specific engineering is included in this table www.ecofastensolar.com .. info@ecofastensolar.com 877-859=3947 a h-„ • r • a�J r •. a • Notes: pr r? Spacing Governed by Snow Load a , - 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standofl 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" .^ 3.) Maximum allowed standoff capcity = 547# (per testing results) ' R 4.) Includes additional factor of safety of 1.5 for lag pullout capacity ' 5.) Values based on a maximum module 16nglh of 70" ' 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height ' •rr , 7.) All adjustment factors are set to 1. No site specific engineering is included in this table www.ecofastensolar.com .. info@ecofastensolar.com 877-859=3947 a .. : • ♦! .. t iy , • . f T - Snow Load 31-40 psf r y Modules in Landscape W .7:12 Wind Speed Exposure 2:12 < Roof Pitch < 6:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 85 mph 110 mph 6 C r,83 e3. �— X83 - 67 59 --51-7 42 51 51 y 'b1r 51 5"'1 2.) Maximum allowed spacing approved by EcoFasten Solar is 72" +` 0 B 83 X93 56 "�'�3 3551 54 `S1 5 bbl! 511, fit .4 61 90 mph . 115 mph C egg, 38 r 01 j 5 1 51. •;• M • 51 32 5f 53 ` 7.) All adjustment factors are set to 1. No site specific engineering is included in this table B 83 45 b1 6t 51 10.0 mph 125 mph C 3 51 32 $1 -5i 51 74 _,. D 43 " 27 b1 St b1 r�. + B 57 36 S1 `51 51 83 70 110 mph 140 mph C 41 26 61 'S 5 L, - _ . J • r D B 59 34 50 22 51 31 b1 46 46 83 1 f 110 mph 120 mph 150 mph C 61 36 22 5 47 47 x__ D 51 30 19 149 40 40 + Notes: q a.�..eJSpacing Govemed by Snow Load 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff. however the designer must round down to meet appropriate rafter spacing y 2.) Maximum allowed spacing approved by EcoFasten Solar is 72" r ° 3.) Maximum allowed standoff capcity = 5476 (per testing results) , t 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module width of 40" • 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feel in height , *' 7.) All adjustment factors are set to 1. No site specific engineering is included in this table , ryr Snow Load 31-40 psf Wind Speed Exposure 2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12 , ASCE 7-05 ASCE 7-10 Cate o Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 - e _ 'j., Y 85 mph f 110 mph C• t3f". _ x__ -- SD „_„_�D_._• 4011x, 38 ,._..,.32" 24 .:20...r. Sit,' _ t"� 31, 31 31 B 49 3ti 3� 1,.1 f3?' 31 90 mph 115 mph ♦ C SQ' 35 22 till w �131t' r 0 AQ --^ B--4� 29 .-411--' 181 —26."` • �. X31 ``4 .34 31 y - ♦ t'106 mph t 125 mph C 29 18 yS[ 311 ` D 42 26 15? . 31 31 r ' B 33~ 20� r3�' -• 110 mph 140 mph C 40 23 14 31 '; �' .31 D 34 19 12 , .,. Sl•. 26 26 120 mph 150 mph i C 35 20 12 i 27 27 • ' L D _ .29— 17 10" 28 E 22 _ 22. Notes: Spacing Governed by Snow Load ,1.) Values in above table represent the maximum allowable spacing in inches Tor pullout forces only on EcoFasten Solar standoff " 2.) Maximum allowed spacing approved by EcoFasten Solar is 48•' "3.) Maximum allowed standoff capcity = 5479 (per testing results) ' 4.) Includes additional factor of safety of 1.5 for lag pullout capacity r 5.) Values based on a maximum module length of 70" A 6.) Based on Risk Category 11 (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table www.ecofastensolar.com :' info@ecofastensolar.com 877-859-3947 '' 9 , 1 ♦ 1 Modules in Landscape - i r 2:12 < Roof Pitch < 6:12 7:12 c Roof Pitch < 12:12 ASCE T-05 ASCE 7-10 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 85 mph 110 mph t —.76Fij ' =66r' i i r 6Grr�. ;,--66 59 51:r f 42 51 �P 51 F '17 51'' I 56 0 ' ;RS :) ZS, 25, 25 25 25 25. 2$ ?B, }25 + 38 32 Modules in Landscape - Wind Speed Exposure Category 2:12 < Roof Pitch < 6:12 7:12 c Roof Pitch < 12:12 ASCE T-05 ASCE 7-10 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 85 mph 110 mph e C —.76Fij ' =66r' i i r 6Grr�. ;,--66 59 51:r f 42 51 �P 51 F '17 51'' -51"=1 51 56 0 ' ;RS :) ZS, 25, 25 25 25 25. 2$ ?B, }25 + 38 32 D $B 35 161 ) '$1'' 51 • 125 mph B ias ` 54 51 i •51' Si 6' 90 mph.' 115 mph C 166 } it 61 38 til 62 51 t D f6@ 51 32 51 • 'k S7 51 ' B 66 45. 51 51 5i $6- 100 mph' 125 mph C 66 '4 51 32 51 Si. 51 D .6$ 43 27 51 51' 51 B c68 57 36 51 57 51 110 mph 140 mph C 136 41 26 51151 61 59 46 46 } . D 34 22 61 B 50 31 517-7517- 66 5 1 47 47 120 120 mph 150 mph C 61 36 22 D 51 30 19 49 40 40. . Notes:. " - Spacing Governed by Snow Load 1.) Values in above table represent the maximurn allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, • however the designer must round down to meet appropriate rafter spacing - 2.) Maximum allowed spacing approved by EcoFasten Solar is 722" ' 3.) Maximum allowed standoff copcity = 547# (per testing results) rr 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module width of 40' ' ` .6.) Based on Risk Category 11 (ASCE 7-10) structures less than 30 feel in height + 7.) All adjustment factors are set to 1. No site specific engineering is included in this table r` ` Snow Load 41-50 psf 1.t Notes: . w 4� Spacing Govemed by Snow Load Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff ' 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" 3.) Maximum allowed standoff capcily = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70' 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table - www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 "to �. 4 t � ; Wind -A Exposure Cate o 2:12 < K < 6:12 7:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 25 25 25 2 26 2S 25 25 25 85 mph ' 110 mph . C D 1140 4R. 40 - 40. �Q 4b, 40,, 40; F+ 4� 11 F' 4 25-yµ _20_,•r25 30 25 22 2S 18 25 18 125 24125. _15,..,-.•24 20 25 1475 122'5 18 _?5 12 ZS 10. 0 ' ;RS :) ZS, 25, 25 25 25 25. 2$ ?B, }25 + 38 32 90 mph 115 mph u B C D C �D +,.,, B C ! D Bl�' C D 35 29 100 mph< 125 mph 29 "26 33 23 19 28 20 17 110 mph s 140 mph 120 mph, r 150 mph. '' .. 35 - .29 �4 1.t Notes: . w 4� Spacing Govemed by Snow Load Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff ' 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" 3.) Maximum allowed standoff capcily = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70' 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table - www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 "to �. 4 t � ; Wind Speed Exposure Cate o 2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 25 25 25 2 26 2S 25 25 25 85 mph ' 110 mph . C D 1140 4R. 40 - 40. �Q 4b, 40,, 40; F+ 4� 11 F' 4 25-yµ _20_,•r25 30 25 22 2S 18 25 18 125 24125. _15,..,-.•24 20 25 1475 122'5 18 _?5 12 ZS 10. 0 ' ;RS :) ZS, 25, 25 25 25 25. 2$ ?B, }25 + 38 32 90 mph 115 mph u B C D C �D +,.,, B C ! D Bl�' C D 35 29 100 mph< 125 mph 29 "26 33 23 19 28 20 17 110 mph s 140 mph 120 mph, r 150 mph. '' .. 35 - .29 - 22 - 22 1.t Notes: . w 4� Spacing Govemed by Snow Load Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff ' 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" 3.) Maximum allowed standoff capcily = 547# (per testing results) 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70' 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height 7.) All adjustment factors are set to 1. No site specific engineering is included in this table - www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 "to �. 4 t � ; s F . >• Snow Load 51-60 psf ; Modules_in Landscape Wind Speed Exposure Category 2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 1 C b5 55 `I 42 34 34= 34 ' �. D 55 - 55 35 3q 34 34 mph .. B 55. 55' 54 34 .34• 34 90 mph 115 mph C 55 1 as' 38 3d 12 24, r ,Zv 1 D B 56 51 32 34 45 34 3A 34 s F . >• Snow Load 51-60 psf ; Modules_in Landscape Wind Speed Exposure Category 2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 85 mph 110 mph C b5 55 `I 42 34 34= 34 ' �. D 55 - 55 35 3q 34 34 mph .. B 55. 55' 54 34 .34• 34 90 mph 115 mph C 55 1 as' 38 3d 12 24, r ,Zv 1 D B 56 51 32 34 45 34 3A 34 34 34 51 100 mph 125 mph C 55 32 I 34 34 34 D 55 43 27 34 34 i 34 'B S6 36 34 34 34 55 110 mph : 140 mph . f .. C 56 41 26 34 34 34 r ' . D Sb' 34 22 34 34' 34 B 95 50 31 34 34 .34 120 mph 150 mph C :SB 36 22 34 34 g4 51 D. 30 19 34 34 L___34 r 7l Notes: ` Spacing Governed by Snow Load , 1 11.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff. however the designer must round down to meet appropriate rafter spacing " 2.) Maximum allowed spacing approved by EcoFasten Solar is 72" „ 3.) Maximum allowed standoff capcity = 547# (per testing results) 4. Includes additional factor of safe of 1.5 for la a ' ) ry g pullout capacity •, , 1 �. 5.) Values based on a maximum module width of 40' • 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feel in height 7.) All adjustment factors are set to 1. No site speck engineering is included in this table _ ' .� ' 7 , Snow Load 51-60 psf y } r: Notes: Spacing Governed by Snow Load } 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" 3.) Maximum allowed standoff capcity = 5470 (per testing results) , 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70" 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height t r. w , •, 1, 7.) All adjustment factors are set to 1. No site specific engineering is included in this table ; y www.6cofastens`olar.com info@ecofastensolar.com ,877-859-3947 e v Wind Speed Exposure 2:12 < Roof Pitch < 6:12 7:12 < Roof Pitch < 12:12 ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 85 mph 110 mph C a s' 24 -F21 � 21 •21 `33 3,T" r 7S. 3i" 23 33:, ti 33 33. 32 20� w30 18 18 2f.r'- 15 20 Z1 z 14 24•, 12 T! ...x`18""' *2'i >2jo t c?f 4 It "2i 21.• 2t' ) <290 21 z 2i i:.. mph .. B 115 mphC22D 125 mphC B .'140 mph C D 34. 29 100 mph' 110 mph 29 26 23 19 —28*— 120 mph 150 mph C 5 20 12 24, r ,Zv 1 29 D 17 10 _21 I 21 Notes: Spacing Governed by Snow Load } 1.) Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff 2.) Maximum allowed spacing approved by EcoFasten Solar is 48" 3.) Maximum allowed standoff capcity = 5470 (per testing results) , 4.) Includes additional factor of safety of 1.5 for lag pullout capacity 5.) Values based on a maximum module length of 70" 6.) Based on Risk Category II (ASCE 7-10) structures less than 30 feet in height t r. w , •, 1, 7.) All adjustment factors are set to 1. No site specific engineering is included in this table ; y www.6cofastens`olar.com info@ecofastensolar.com ,877-859-3947 GrounDinG inFormaTion The rail -free Rock -It System maybe used to mount and ground PV modules that comply with UL 1703, only when tha.- specific module has been evaluated for mounting and grounding, in compliance with the included installation instructions. Note: Grounding lug must be visible to inspectors from the entire perimeter of the PV array. Multiple Use Grounding Pins Grounding pins within the Mid -Clamp are multiple use bonding/grounding devices. Modules will need to be adjusted if the Mid -Clamps are loosened to ensure there is "new" metal to pierce into upon retightening. Grounding Method Rock -It 2.0 Mount bonds N -S rows of modules i Rock -It 2.0 Coupling bonds E -W rows of modules r Array Skirt 2.0 bonds E -W along the entire array when installed One Burndy CL50-1 TN ground lug is required per PV array, limited to 300 modules placed in either portrait or landscape orientation. BonDinG AssemBLg anD BonDInG haTH I Bond Path ® Grnunding Lug ouct ttrmrnrl6yt CorMuctofIEGCI- Integrated Bonding Senermy to eaap ynvnn s Rock -IE Couoling ■ Nn[k It .Unum Rock -I( Array Skirt I Bond Pnrh Bond Path 09 Grounding Lug Is Grounding Lug Gr Equipment ounding Conciunor lEGCI- to W. Equipment Grounding generally ground Coutluctor (EGO Rock•IC Coupling 9-11y it,nk Ba w 0 1 Rock -I[ Couplinp, • ROCK -11 Mount: Rock -R Array Skirc ■ Rock•I[Mount Rock -It .Array Skirt www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 12 i THermaL ExPansion anD BonDInG A thermal'expansion gap is required per each continuous 40' length of modules. ' L Omit a coupling and leave a 2" gap in the array skirt and also between the modules at that point. - BracKeT sPacinG Portrait Orientation r -M Landscape Orientation Bond Path is Grounding Lug Equipment Grounding T C0noucror(CGQ. generally 1. cvlh ground Rock -it Coupling 0 Rock -It Mount Rock -It Array Skirt II '� 32mm, 35mm & 40mrri Modules: ` Max east/west bracket spacing is 72"OC. Maximum east/west bracket spacing is 48"OC. 32mm Modules: Max east/west bracket spacing is 48"OC. u . . Spacing may vary depending upon project specific structural requirements; i.e. high snow and wind load areas may require lesser spacing E -W than the maximum. "STaGGereD LaYOUT canTILever anD oFFseT Staggered Mounting Points t.cer{dlever TI -4, , .. . ® Rock -It Mount ®Rock -It Coupling The array layout instructions in this installation manual offer a general overview of layout. Periodically, due to a variety of factors (roof obstacles, shading, etc.) other layouts are required. www.ecofastensolar.com Cantilever: Maximum cantilever is 1/3 bracket spacing. For portrait orientation installations, check layout prior to installing. Offset: Offset from all roof edges depends an wind speed, snow loads, local fire and building codes per location info@ecofastensolar.com 877-859-3947 ' 13 Its ROCK -IT S�JSTem 2.0 EvaLuaTeD, comPaTIBLe MODULes Module Manufacturer Model Type (X used to indicate variable test) Module Dimensions (mm) Module Dimenslons (In) Trina Solar TSM-XXX-PX05.08 1540 x 992 x 40 64.57 x 39.06 x 1.57 Canadian Solar CS6P-XXXM 1638 x 982 x40 64.50 x 38.70 x 1.57 Canadian Solar CS6P-XXXP 1638 x 982 x 40 64.50 x 38.70 x 1.57 Jinko Solar JKMXXXP-60 1650 x 992 x 40 65.00 x 39.05 x 1.57 Jinko Solar JKMXXXM-60 1650 x 992X 40 65.00 x 39.05 x 1.57 Jinko Solar JKMXXXPP-60 1650 x 992 x 40 65.00 x 39.05 x 1.57 Jinko Solar JKMXXXMM-60 1650 x 992 x 40 65.00 x 39.05 x 1.57 Yingli Solar YL2XXP-29b 1550 x 990 x 40 65.00 x 38.98 x 1.57 LG Electronics LG300N1C-B3 1640 x 1000 x 35 64.57 x 39.37 x 1.38 LG Electronics LG300N1K-G4 1640 x 1000 x 40 64.57 x 39.37 x 1.57 Axitec Solar AC-XXXM/156-60S 1640 x 992 x 40 64.57 x 39.06 x 1.57 RECOM RCM-XXX-6MB 1640 x 992 x 35 64.60 x 39.00 x 1.38 Silfab SLA 2XXP 1650 x 99D x 38 64.96 x 38.98 x 1.50 Solaria PowerXT XXXR-BX 1621 x 1056 x 40 63.82 x 41.57 x 1.57 Hanwha Q Cells Q.PRO G4 2XX• 1670 x 1000 x 32 65.70 x 39.40 x 1.26 Hanwha Q Cells Q.PLUS BFR G4.1 XXX' 1670 x 1000 x 32 65.70 x 39.40 x 1.26 Hanwha Q Cells Q. PRO BFR G4 XXX" 1670 x 1000 x 32 65.70 x 39.40 x 1.26 Hanwha Q Cells 0. PRO 8FR G4.1 XXX' 1670 x 1000 x 32 65.70 x 39.40 x 1.26 Hanwha Q Cells Q.PRO BFR G4.3 XXX` 1670 x 1000 x 32 65.70 x 39.40 x 1.26 Hanwha Q Cells Q.PEAK G4.1 XXX' 1670 x 1000 x 32 65.70 x 39.40 x 1.26 Hanwha Q Cells I Q.PEAK BLK G4.1 XXX' 1670 x 1000 x 32 65.70 x 39.40 x 1.26 Hanwha Q Cells B.LINE PLUS BFR G4.1 XXX' 1670 x 1000 x'32 65.70 x 39.40 x 1.26 Hanwha Q Cells B.LINE PRO 9FR G4.1 XXX' 1670 x 1000 x 32 65.70 x 39.40 x 1.26 'Hanwha 32mm modules to be used with special order Rock -it System components. Call for details. • Fastest, easiest to level system on the market SIMPLE- only 4 components Conforms to UL 2703 First Edition North-South adjustability - Class A Fire rating with Type 1 modules Only one tool required (1/2" deep well socket) • Integrated electrical bonding Max No. of Panels 300 Modules per ground lug Materials 300 Series Stainless Steel 6000 Series Aluminum Max System voltage 1000VDC Coating Black Andodization/Mill Finish Class A Fire Rating With UL 1703 Type 1 Rated Modules Lug Specifications Burndy CLSO-ITN Ground Lug (UL Listing #KDER E9999) Leveling Range 3-4" Ground Wire Per above Lug spec. 14 AWG 4 AWG Copper Ground Wire Rock -It Slide -Comp 2.0 Range Rock -It Slide -Tile 2.0 Range 3" 7" Max Module Size 64.96•(1650mm) x 39.05'(992mm) x 2"(50mm) Min/Max Roof Slope 1/2:12/12:12 Max Downforce/Uplift Rating 45 PSF Max Anchor Spacing (35mm/40mm) Max Anchor Spacing (32mm) 72" 48" Rock -It Mount Load Rating 547lbs with Single 5/16" Lag 3.0 Safety Factor Skirt Box QTY 6 units Slide Fastening Hole 5/16"diameter Mount Box QTY 12 units (Module Cantilever Maximum cantilever is 1/3 bracket spacing Rock -It Slide Box QTY SO units Coupling Box QTY 12 units Warranty 20 Year Material and Workmanship Spstemmalting (placed onside alandenide Codes: National Electric Code, ANSI/NFPA 70, NEC 250, NEC 690, IRC, IBC ofRock-1I.NountmdCoupling) Standards: UL 2703 First Edition, UL 1703 ' : EcoFasten Salar- RUCK-rf SYS'I EM N.FGIa maE:xxxaa-aYri CONFORMSTO UL 7703 Ec®Fasten Solar www.ecofastensolar.com info@ecofastensolar.com 877-859-3947 14