HomeMy WebLinkAbout040-140-015 (2)t
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Langerwerf Res , Calculation Date/Time: 12:27, Fri, Nov 17, 2017 Page 1 of 12
Calculation Description: Title 24 Analysis Input File Name: T-24 Langerwerf-plancheck.ribdl6x
B17-248=1 - - TRB
GENERAL INFORMATION
01 Project Name Langerwert Res
02 Calculation Description Title 24 Analysis
03 . Project Location Durham Dayton Hwy
I
,_ -
I-.-NOVEMBER-21,2017'
I
- - -- —040-140-01-5)
- - (,�'t-' �"-(� 11 '-r M
y R. E C, t 1 EC K'#?' ` "-
04
City Durham
05
Standards Version Compliance 2017
06
Zip Code 95938
07
Compliance Manager Version
BEMCmpMgr 2016.3.0 (934 SP1)
08
- Climate Zone CZ11
09
Software Version
EnergyPro 7.2
10
Building Type Single Family
11
Front Orientation (deg/Cardinal) 270
12
Project Scope Newly Constructed
13
Number of Dwelling Units
1 REVIEWED
14
Total Cond. Floor Area (ft2) 3712
15
Number of Zones
2 -0K COUL Cu
16
Slab Area (ft2) 0
17
Number of Stories
2
18
Addition Cond. Floor Area(ft2) n/a
19
Natural Gas Available
Yes
20
Addition Slab Area (ft2) n/a
21
Glazing Percentage (%)
12.0%
COMPLIANCE RESULTS J --z-
01 Building Complies witl Compute( Performance''
02 This building incorporates featuresathat require field-testing and/or4verification,by a:certified,HERS rater.underthe supervision of a CEC-approved HERS provider.
03 This building incorporates one-ormore Special -Features shown below tr
V 1"1 1~ " 5 1-1 1-1 CJ V 1 U l= 1-{
PERMII # "
BUTTE COUNTY DEVELO MENT SERVICES
REVIEWED FOR
CODE COMPLIA CE
DATE 12� 1� BY
Registration Number: 217-Po10312756B-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
RECEIVE®
NOV 2 l 2017
TRB AND ASSOCIATES
Registration Date/Time: 2017-11-17 14:21:42 HERS Provider: CaICERTS inc.
Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-17 12:29:25
F1 Le, CDS
ANCE
kTES
N
Q
Z<
ENERGY USE SUMMARY
04
05
06
07
08
Energy Use (kTDV/ft2-yr)
Standard Design
Proposed Design
Compliance Margin
Percent Improvement
Space Heating
" 19.12
21.18
-2.06
-10.8%
Space Cooling
33.69
31.48
2.21
6.6%
IAQ Ventilation
1.16
1.16
0.00
0.0%
Water Heating
5.95
5.91
0.04
0.7%
Photovoltaic Offset
—
0.00
0.00
--
Compliance Energy Total
59.92
59.73
0.19
0.3%
PERMII # "
BUTTE COUNTY DEVELO MENT SERVICES
REVIEWED FOR
CODE COMPLIA CE
DATE 12� 1� BY
Registration Number: 217-Po10312756B-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
RECEIVE®
NOV 2 l 2017
TRB AND ASSOCIATES
Registration Date/Time: 2017-11-17 14:21:42 HERS Provider: CaICERTS inc.
Report Version - CF1R-09012017-934 SP1 Report Generated at: 2017-11-17 12:29:25
F1 Le, CDS
ANCE
kTES
N
Q
Z<
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Langerwerf Res Calculation Date/Time: 12:27, Fri, Nov 17, 2017
Calculation Description: Title 24 Analysis Input File Name: T-24 Langerwerf-plancheck.ribd16x
t •. z tCF1R-PRF-01
Page 2 of 12
ENERGY DESIGN RATING
Energy Design Rating (EDR) is an alternate way to express the energy performance of a building using a scoring system where 100 represents the energy performance of the Residential
Energy Services (RESNET) reference home characterization of the 2006 International Energy Conservation Code (IECC) with California modeling assumptions. A score of zero represents
the energy performance of a building that combines high levels of energy efficiency with renewable generation to"zero out" its TDV eneigy. Because EDR includes consideration of
components not regulated by Title 24, Part 6 (such as domestic appliances and consumer electronics), it is not used to show compliance with Part 6 but may instead be used by local
jurisdictions pursuing local ordinances under Title 24, Part 11 (CALGreen).
As a Standard Design building under the 2016 Building Energy Efficiency Standards is significantly more efficient than the baseline EDR building, the EDR of the Standard Design building
is provided for Information. Similarly, the EDR score of the Proposed Design is provided separately from the EDR value of installed PV so that the effects of efficiency and renewable
energy can both be seen
EDR of Standard Efficiency EDR of Proposed Efficiency EDR Value of Proposed PV + Battery Final Proposed EDR
49.3 49.1 1 0.0 49.1
❑ Design meets Tier 1 requirement of 15% or greater code compliance margin (CALGreen A4.203.1.2.1) and QII verification prerequisite.
❑ Design meets Tier 2 requirement of 30% or greater code compliance margin (CALGreen A4.203.1.2.2) and QII verification prerequisite.
❑ Design meets Zero Net Energy (ZNE) Design Designation requirement for Single Family in climate zone CZ11 (Red Bluff) (CALGreen A4.203.1.2.3) including on-site
photovoltaic (PV) renewable energy generation sufficient to achieve a Final Energy Design Rating (EDR) of zero or less. The PV System must be verified.
Notes:
• Excess PV Generation EDR Credit: Bypassing PV size limit may violate Net Energy Metering NEM rules
REQUIRED SPECIAL FEATURES\`\
Y
r --.A ,— - . ice-+/ �
The following are features that must be installed as condition for meeting the.modeledi energy: performanci ie for...tthis computer analy}sis,,
• Window overhangs and/or finsj r 1
• Non-standard duct location (any location otherthan,attic) U O
• Northwest Energy Efficiency Alliance (NEEA) rated heat pump )rater heater; _specific brand/model, or equivalent,;must be installed,,
HERS FEATURE SUMMARY
The following is a summary of the features that must be field -verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is
provided in the building components tables below.'
'
Building -level Verifications:
• IAQ mechanical ventilation
BUTTE COU NTY
BU
Cooling System Verifications:
• Minimum Airflow
BUILDING DIVISION
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
r V
APPROVED
• Fan Efficacy Watts/CFM
HVAC Distribution System Verifications:
• Duct Sealing
• Ducts located entirely in conditioned space confirmed by duct leakage testing
Domestic Hot Water System Verifications:
• — None —
Registration Number: 217-P0103127568-000-000-0000000-0000 Registration Date/Time: 2017-11-17 14:21:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-17 12:29:25
1i,
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Langerwerf Res Calculation Date/Time: 12:27, Fri, Nov 17, 2017
Calculation Description: Title 24 Analysis
Input File Name: T-24 Langerwerf-plancheck.ribdl6x
CF1 R -PRF -01
Page 3 of 12
BUILDING - FEATURES INFORMATION
01
02
03
.04
05
06
07
Project Name
Conditioned Floor Area (ft2)
Number of Dwelling
Units
Number of Bedrooms
Number of Zones
Number of Ventilation
Cooling Systems
Number of Water
Heating Systems
Langerwerf Res
3712
1
6
2
0
1
ZONE INFORMATION
01
02
03
04
05
06
07
Zone Name
Zone Type
HVAC System Name
Zone Floor Area
(ft)
Avg. Ceiling
Height
Water Heating System 1
Water Heating System 2
1st Floor
Conditioned
First Floorl
2542
9
DHW Sys 1
n/a
2nd Floor
Conditioned
Second Floor2
1170
8
DHW Sys 1
n/a
OPAQUE SURFACES
1
01
1�' 02
03
04
05
06
07
08
Name
` "r Zone
Construction
Azimuth
Orientation Gross Area (ft2)
Window & Door Area (ft2)
Tilt (deg)
Front -W
1st Floor.`y
2x6 -R,21, ow oft X270
# Front
351
86.007
90
Right -S
,1st,Fl6or t
2x6 -144,21x
%180
LRight At w
144
48.5
90
Back -E
% 1st FI or2x6-R=21
0 A
� _9_61 M
I LBack� � � �
810
206.014
90
Left -N
1 st F �� C
,2x6 -R-21
V0� w t
Left
414
40
90
Garage
1st Floor~ Y
y ` 'R'21 Wall ` y
"y 270
' Fro t Y
252
21
90
Interior Surface
1st Floor>> Garage_
R-21 Walll
n/a
n/a
252
0
n/a
Roof
1st Floor
R-38 SPF Roof Deck
n/a
n/a
1372
n/a
n/a
Raised Floor
1st Floor
R-22 Floor Crawlspace
n/a
n/a
2542
n/a
n/a
Front -W 2
2nd Floor
2x6 -R-21
270
Front
351
21
90
Right -S 2
2nd Floor
2x6 -R-21
180
Right
351
66
90
Back -E 2
2nd Floor
2x6 -R-21
90
Back
351
20
90
Left -N 2
2nd Floor
2x6 -R-21
0
Left
351
0
90
Roof 2
2nd Floor
R-38 SPF Roof Deck
n/a
n/a
1170
n/a
n/a
INTERIOR FLOOR
2nd Floor»1st Floor SECOND STORY FLOOR
n/a
n/a
1170
n/a
n/a
Left -N 3
Garage_
R-19 Wall
0
Left
330
40
90
Front -W 3
Garage_
R-19 Wall
270
Front
280
28
90
Right -S 3
_Garage_
R-19 Wall
0
Left
330
192
90
Roof 3
_Garage_
R-38 SPF Roof Deck
n/a
n/a
9
n/a
R `��'7+rLr ...� • _ - `°��`19'
Registration Number: 217-P010312756B-000-000-0000000-0000 Registration Date/Time: 2017-11-17 14:21:42 BUIIIIrDIV'SI� caiCERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1R-09012017-934 SP1 �1 to 1- 7 12:29:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01
Project Name: Langerwerf Res Calculation Date/Time: 12:27, Fri, Nov 17, 2017 Page 4 of 12
Calculation Description: Title 24 Analysis Input File Name: T-24 Langerwerf-plancheck.ribdl6x
ATTIC
01
02
03
04
05
06
07
08
Name
Construction
Type
Roof Rise
Roof Reflectance
Roof Emittance
Radiant Barrier
Cool Roof
Attic 1st Floor
Attic Rooflst Floor
Unventilated
9
0.1
0.85
No
No
Attic 2nd Floor
Attic Roof2nd Floor
Unventilated
3
0.1
0.85
No
No
Attic Garage_
Attic Garage Roof Cons _
Unventilated
1 0
0.1
0.85
No
No
1,
---Cvz:;A CE.RTS, nc.
HSPS PROVIDER
BUTTE COUNTY
BUILDING DIVISION
APPROVED
Registration Number: 217-P010312756B-000-000-0000000-0000 Registration Date/Time: 2017-11-17 14:21:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-17 12:29:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Langerwerf Res Calculation Date/Time: 12:27, Fri, Nov 17, 2017
Calculation Description: Title 24 Analysis
Input File Name: T-24 Langerwerf-plancheck.ribd16x
CFI R -PRF -01 -
Page 5 of 12
FENESTRATION / GLAZING
01
02
03
04
05
06
07
08
09
10
Name
i
Type Surface (Orientation -Azimuth)
Width (ft)
Height
(ft)
Multiplier
Area
(ft2)
U -factor
SHGC
Exterior Shading
1668 Entry Side Light
Window
Front -W (Front -270)
1.5
6.8
0.988
10.0
0.28
0.21
Insect Screen (default)
1668 Entry Side Light 2
Window
Front -W (Front -270)
1.5
6.8
0.988
10.0
0.28
0.21
Insect Screen (default)
3030 CSMT
Window
Front -W (Front -270)
3.0
3.0
1
9.0
0.28
0.21
Insect Screen (default)
3030 CSMT 2
Window
Front -W (Front -270)
3.0
3.0
1
9.0
0.28
0.21
Insect Screen (default)
3030 CSMT 3
Window
Front -W (Front -270)
3.0
3.0
1
9.0
0.28
0.21
Insect Screen (default)
3030 CSMT 4
Window
Front -W (Front -270)
3.0
3.0
1
9.0
0.28
0.21
Insect Screen (default)
3030 CSMT 5
Window
Front -W (Front -270)
3.0
3.0
1
9.0
0.28
0.21
Insect Screen (default)
2030 SH
Window
Right -S (Right -180)
-
--
1
6.0
0.28
0.21
Insect Screen (default)
5040 CSMT
Wndow'
Right -S (Right -180)
-
-
1
20.0
0.28
0.21
Insect Screen (default)
1650 CSMT -
Wndow r' E
Right -S (Right -180)
-
-
1
7.5
0.28
0.21
Insect Screen (default)
1650 CSMT 2
Window -Right-S (Right -180)
--
-
1
7.5
0.28
0.21
Insect Screen (default)
1650 CSMT 3
Window
Right -S (Right180)! r" -'-e-
1
7.5
0.28
0.21
Insect Screen (default)
1668 Side Light
Window . (�
Back -t (Back -,90) � � 1.5
'1 .8
6.988 j
' 10.0
0.28
0.21
Insect Screen (default)
6068 FR DR
Window
� Back-`E"(back 90)•---'• I
�136.0J
6.8
U1 U ':=40.5
0.28
0.21
Insect Screen (default)
1668 Entry Side Light 3
Window ow
5 P
H 1.5D
.V6.81
X0.988
.J10.0
0.28
0.21
Insect Screen (default)
3030 CSMT 6
Window
Back -E (Back -90)
3.0
3.0
1
9.0
0.28
0.21
Insect Screen (default)
3030 CSMT 7
Window
Back -E (Back -90)
3.0
3.0
1
9.0
0.28
0.21
Insect Screen (default)
4040- CSMT
Wndow
Back -E (Back -90)
4.0
4.0
1
16.0
0.28
0.21
Insect Screen (default)
1668 Side Light 2
Window
Back -E (Back -90)
1.5
6.8
0.988
10.0
0.28
0.21
Insect Screen (default)
6068 FR DR 2
Window
Back -E (Back -90)
6.0
6.8
1
40:5
0.28
0.21
Insect Screen (default)
1668 Side Light 3
Window
Back -E (Back -90)
1.5
6.8
0.988
10.0
0.28
0.21
Insect Screen (default)
4040- CSMT 2
Window
Back -E (Back -90)
4.0
4.0
1
16.0
0.28
0.21
Insect Screen (default)
1650 CSMT 4
Window
Back -E (Back -90)
1.5
5.0
1
7.5
0.28
0.21
Insect Screen (default)
4050 CSMT
Window
Back -E (Back -90)
4.0
5.0
1
20.0
0.28
0.21
Insect Screen (default)
1650 CSMT 5
Window
Back -E (Back -90)
1.5
5.0
1
7.5
0.28
0.21
Insect Screen (default)
2650 CSMT
Window
Left -N (Left -0)
2.5
5.0
1
12.5
0.28
0.21
Insect Screen (default)
2650 CSMT 2
Window
Left -N (Left -0)
2.5
5.0
1
12.5
0.28
0.21
Insect Screen (default)
4016 SL
Window
Left -N (Left -0)
4.0
1.5
1
1 6.0
0.28
0.21
Insect Screen (default)
3016 SL
Window
Left -N (Left -0)
3.0
1.5
1
4.5
0.28
0.21
Insect Screen (default)
IfsU1 1t UVVINI Y
Registration Number: 217-P010312756B-000-000-0000000-0000 Registration DatefFime: 2017-11-17 14:21:42 B�I ell® rU1�\ /I 19NCaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 o enerated at: 210 1 17 12:29:25
APPROVED
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Langerwerf Res
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:27, Fri, Nov 17, 2017
Input File Name: T-24 Langerwerf-plancheck.ribd16x
CF1R-PRF-01
a Page 6 of 12
3016 SL 2
Window
Left -N (Left -0)
3.0 1.5 1
4.5
0.28
1 0.21
Insect Screen (default)
5040 CSMT 2
Window
Right -S 2 (Right -180)
- - 1
20.0
0.28
0.21
Insect Screen (default)
2030 SH 2
Window
Right -S 2 (Right -180)
- - 1
6.0
0.28
0.21
Insect Screen (default)
5040 CSMT 3
Window
Right -S 2 (Right -180)
- - 1
20.0
0.28
0.21
Insect Screen (default)
5040 CSMT 4
Window
Right -S 2 (Right -180)
- - 1
20.0
0.28
0.21
Insect Screen (default)
5040 CSMT 5
Window
Back -E 2 (Back -90)
- - 1
20.0
0.28
0.21
Insect Screen (default)
5040 CSMT 6
Window
Left -N 3 (Left -0)
- - 1
20.0
0.28
1 0.21
Insect Screen (default)
5040 CSMT 7
Window
Left -N 3 (Left -0)
- - 1
20.0
0.28
0.21
Insect Screen (default)
1640 CSMT
Window
Front -W 3 (Front -270)
- - 1
6.0
0.28
0.21
Insect Screen (default)
4040 CSMT
Window
Front -W 3 (Front -270)
- - 1
16.0
0.28
0.21
Insect Screen (default)
1640 CSMT 2
Window
Front -W 3 (Front -270)
- - 1
6.0
0.28
0.21
Insect Screen (default)
OPAQUE DOORS
01 I /' 1 ��
02
03
04
Name-, - -- -'''
Side of Building
Area (ft)
U -factor
3068 Entry
Front -W _ _ _
21.0
0.50
Door i E Cr
j L, Garage r,'�
21.0
0.50
Door to attic l `,f i'
Front,W 2 11
21.0
0.50
Ins. Garage Door,rRight,-S
3 �.� .
128.0
0.20
Ins. Garage Door 2 ` s ti - } -;r
; Right -§'3 +"� t >r� �" I N
64.0
0.20
t.
Registration Number: 217-P010312756B-000-000-0000000-0000
CA Building Energy Efficiency Standards - 2016 Residential Compliance
APp G pjv s o� N
�oVED
Registration Dateffime: 2017-11-17 14:21:42
Report Version - CF1R-09012017-934 SP1
HERS Provider: CaICERTS inc.
Report Generated at: 2017-11-17 12:29:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Langerwerf Res
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:27, Fri, Nov 17, 2017
Input File Name: T-24 Langerwerf-plancheck.ribd16x
CFIR-PRF-01
Page 7 of 12
OVERHANGS AND FINS
01
02
03
04 1
05
06
07
08
09
10
11
1 12 1
13
1 14
Overhang
Left Fin
Right Fin
Window
Depth
Dist Up
Left
Extent
Right
Extent
Flap Ht.
Depth Top Up
Dist L
Bot Up
Depth
Top Up
Dist R
Bot Up
1668 Entry Side Light
10
2
10
10
0
0
0
0
0
0
0
0
0
1668 Entry Side Light 2
10
2
10
10
0
0
0
0
0
0
0
0
0
3030 CSMT
8
1
8
8
0
0
0
0
0
0
0
0
0
3030 CSMT 2
8
1
8
8
0
0
0
0
0
0
0
0
0
3030 CSMT 3
8
1
8
8
0
0
0
0
0
0
0
0
0
3030 CSMT 4
8
1
8
8
0
0
0
0
0
0
0
0
0
3030 CSMT 5
8 J^j
1
8
8
0
0
0
0
0
0
0
0
0
1668 Side Light
10,,
2
10
10
0
0
0
0
0
0
0
0
0
6068 FR DR
101 2
10
10
0
0
0
0
0
0
0
0
0
1668 Entry Side Light 3
10'
"-2
--10- -'
10
0
0
0
0
0
0
0
0
0
3030 CSMT 6
\\8
��
�:=8
n 8-=:)r""'x— 0 1-
A, O
`On
0
0
0
0
0
0
3030 CSMT 7
8_%
' 1
{ 8 �
8
J r`�'- O. re
I i 0,
oil
O?-�
0
0
0
0
0
4040-CSMT
�8���r1
`8
8 �� 0�
OCA j�j
0�3i
{j 0
0
0
0
0
0
1668 Side Light 2
% 10
H10 F
P10q
j~0 R
(`0 v !
37-5 15 0R
0
0
0
0
0
6068 FR DR 2
10
2
10
10
0
0
0
0
0
0
0
0
0
1668 Side Light 3
10
2
10
10
0
0
0
0
0
0
0
0
0
4040- CSMT 2
8
1
8
8
0
0
0
0
0
0
0
0
0
1650 CSMT 4
8
1
8
8
0
0
0
0
0
0
0
0
0
4050 CSMT
8
1
8
8
0
0
0
0
0
0
0
0
0
1650 CSMT 5
8
1
8
8
0
0
0
0
0
0
0
0
0
2650 CSMT
8
1
8
8
0
0
0
0
0
0
0•
0
0
2650 CSMT 2
8
1
8
8
0
0
0
0
0
0
0
0
0
4016 SL
8
1
8
8
0
0
0
0
0
0
0
0
0
3016 SL
8
1
8
8
0
0
0
0
0
0
0
0
0
3016SL2
8
1
8
8
0
0
0
0
0
0
0
0
0
Registration Number: 217-Po10312756B-000-000-0000000-0000 Registration Date/Time: 2017-11-17 14:21:42
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1
BUTTE COUNTY
BUILDING DIVISION
AP Ftl$MYED CaICERTS inc.
Report Generated at: 2017-11-17 12:29:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Langerwerf Res
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:27, Fri, Nov 17, 2017
Input File Name: T-24 Langerwerf-plancheck.ribd16x
CFI R -PRF -01
Page 8 of 12
OPAQUE SURFACE CONSTRUCTIONS
01
02
03
04
05
06
07
Total Cavity
Winter Design
Construction Name
Surface Type
Construction Type
Framing
R -value
U -factor
Assembly Layers
• Inside Finish: Gypsum Board
R 19 in 5-1/2 in.
Cavity/Frame: R-19 in 5-1/2 in. (R-18) /2x6
R-19 Wall
Exterior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
cavity (R-18)
0.074
Exterior Finish: 3 Coat Stucco
Ceilings (below
Inside Finish: Gypsum Board
R-38 SPF Roof Deck
attic)
Wood Framed Ceiling
2x4 @ 24 in. O.C.
none
0.481
Cavity/Frame: no insul. /2x4
• Around Roof Joists: R-25.0 insul.
• Cavity/Frame: R -13.0/2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Garage Roof Cons
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 38
0.037
Roofing: Light Roof (Asphalt Shingle)
A
Around Roof Joists: R-25.0 insul.
J
Cavity/Frame: R -13.0/2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Rooflst Floor
Attic Roofs'� �.
\Wood Framed Ceiling
in. O.C.
R 38
0.037
Roofing: Light Roof (Asphalt Shingle)
Inside Finish: Gypsum Board
r
/r <^ w
�
Cavity/Frame: R -13/2x6
Exterior Finish: Wood
2x6 -R-21
ExterioriWaits/
� Wood Framed Wally
2x6',@:16 im,
R 13, �
1t /OA83
Siding/sheathing/decking
U k1 Uf7
U U
U p
Inside Finish: Gypsum Board
R-21 Wall
Exterior Walls
Wood Framed'WalliE
2x6 @ 16 in. O C. �%
R 21� t
' x0.069
Cavity / Frame: R-21 / 2x6
Exterior Finish: 3 Coat Stucco
• Floor Surface: Carpeted
Floors Over
Floor Deck: Wood Siding/sheathing/decking
R-22 Floor Crawlspace
Crawlspace
Wood Framed Floor
2x8 @ 16 in. O.C.
R19
0.047
Cavity/Frame: R -19/2x8
• Inside Finish: Gypsum Board
• Cavity/Frame: R -21/2x6
R-21 Walll
Interior Walls
Wood Framed Wall
2x6 @ 16 in. O.C.
R 21
0.064
Other Side Finish: Gypsum Board
• Around Roof Joists: R-25.0 insul.
• Cavity/Frame: R -13.0/2x4 Top Chid
2x4 Top Chord of Roof Truss @ 24
Roof Deck: Wood Siding/sheathing/decking
Attic Roof2nd Floor
Attic Roofs
Wood Framed Ceiling
in. O.C.
R 38
0.037
Roofing: Light Roof (Asphalt Shingle)
• Floor Surface: Carpeted
• Floor Deck: Wood Siding/sheathing/decking
• Cavity/Frame: no insul. /2x12
SECOND STORY FLOOR
Interior Floors
Wood Framed Floor
2x12 @ 24 in. O.C.
none
0.200
Ceiling Below Finish: Gypsum Board
BUTTE COUNTY
BUILDING DIVISION
Registration Number: 217-Po10312756B-000-000-0000000-0000 APPI F3is aVnnCm
ege: 2017-11-1714:21:42
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1
1
HERS Provider: CaICERTS inc.
Report Generated at: 2017-11-17 12:29:25
CERTIFICATE OF COMPLIANCE.- RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Langerwerf Res Calculation Date/Time: 12:27, Fri, Nov 17, 2017
Calculation Description: Title 24 Analysis
Input File Name: T-24 Langerwerf-plancheck.ribdl6x
BUILDING ENVELOPE - HERS VERIFICATION 11 1 '
01 02 03 04
Quality Insulation Installation (QII) Quality Installation of Spray Foam Insulation Building Envelope Air Leakage CFM50
Not Required Not Required Not Required n/a
CF1R-PRF-01
Page 9 of 12
WATER HEATING SYSTEMS
-01 02 03 04 - 05 06
Name System Type Distribution Type Water Heater Number of Heaters Solar Fraction (%)
DHW Sys 1 DHW Standard DHW Heater 1 (1) 1 .0%
WATER HEATERS
01
02
03
04
05
06
07
08
09
10
11
12
First Floorl
Heat Pump Heating and
Cooling System
/ t
Heat Pump System 1
HVAC Fan 1
Air Distribution System 1
Input Rating /
Tank
Standby
Heat Pump System 2
HVAC Fan 2
Air Distribution System 2
9
Heater
1 '`
16
Tank
Uniform Energy
Pilot /
Insulation
Loss/
First Hour
1
Tank Location
32800
Element
16
Number
Volume
Factor / Energy
Thermal
R -value
Recovery
Rating /
NEEA Heat Pump
or Ambient
Name
Type
Tank Type
of Units
(gal)
Factor I Efficiency
Efficiency
(Int(Ext)
Eff
Flow Rate
Brand / Model
Condition
' '"
A. O. Smith /
DHW Heater 1
Heat Pump
�h/a
1n/a�
`
NEE♦A Rated
i
n/a f
—17
n/a jj
Q
n/a
n/a
HP10-80H45DV (80
_Garage_
f^
I
I( t:;�
1I Il-^~ I
1E Jt 1
1
4::::-, 0-�
I
gal)
SPACE CONDITIONING SYSTEMS % Zz- 4 , '� " U U U t� n 0 U U \1�1 �
01
02(«
03" �r ("
; j [ 404) J= Q
05
06
SC Sys Name
System Type
Heating Unit Name
Cooling Unit Name
Fan Name
Distribution Name
First Floorl
Heat Pump Heating and
Cooling System
Heat Pump System 1
Heat Pump System 1
HVAC Fan 1
Air Distribution System 1
Second Floor2
Heat Pump Heating and
Cooling System
Heat Pump System 2
Heat Pump System 2
HVAC Fan 2
Air Distribution System 2
HVAC - HEAT PUMPS
01
02
03
04 05 1 06
07 08
09
10
11
Name
System
Type
Number of
Units
Heating
Cooling
Zonally
Controlled
Compressor
Type
HERS
Verification
HSPF/COP
Cap 47
Cap 17
SEER
EER
Heat Pump System 1
SplitHeatPump
1
9
32800
30000
16
13
Not Zonal
Single Speed
Heat Pump System
1 -hers -cool
Heat Pump System 2
SplitHeatPump
1
9
32800
30000
16
13
Not Zonal
Single Speed
Heat Pump System
2 -hers -cool
Registration Number: 217-P010312756B-000-000-0000000-0000 Registration Date/Time: 2017-11-17 14:21:42
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1
BUiT'E COUNTY �
BUILDING
AREp
Generate®�-D12'29:25S inc.
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Langerwerf Res Calculation Date/Time: 12:27, Fri, Nov 17, 2017
Calculation Description: Title 24 Analysis
Input File Name: T-24 Lange rwerf-plancheck. ribd 1 6x
CF1 R -PRF -01
Page 10 of 12
HVAC COOLING - HERS VERIFICATION
01
02
03
04
05
06
Name
Verified Airflow
Airflow Target
Verified EER
Verified SEER
Verified Refrigerant
Charge
Heat Pump System 1 -hers -cool
Required
350
Required
Required
Required
Heat Pump System 2 -hers -cool
--------------
Required
350
Required
Required
Required
HVAC - DISTRIBUTION SYSTEMS
01
02
03
04
05
06
07
Name
Type
Duct Leakage
Insulation R -value
Duct Location
Bypass Duct
HERS Verification
Air Distribution System 1
DuctslnAll
Sealed and tested
8
Conditioned zone
None
Air Distribution System
1 -hers -dist
Air Distribution System 2
' 1
DuctsInAll
i . }
Sealed and tested
8
Conditioned zone
None
Air Distribution System
2 -hers -dist
HVAC DISTRIBUTION -HERS VERIFICATIONi j
01
.'� 02 r
03
04
05
06
07
08
Name
Duct Leakage
1 Ver ficatian
^Duct Leakage
�Tget�(%})f
(Verified Duct—
r--L`ocation
;rified Duct
Uesign
Buried
Ducts
Deeply Buried
Ducts
Low -leakage
Air Handler
Air Distribution System 1 -hers -dist
J /Required tw 4
5.0 ��
L -=Required U
C:Not`Required U
UNofRequired
Not Required
Na
Air Distribution System 2 -hers -dist
Required
1HF5-0R,
R qui ed CNgfRequired
E Not Required
Not Required
Na
HVAC -FAN SYSTEMS
01
01
02
03
04
Name
Type
Fan Power (Watts/CFM)
HERS Verification
HVAC Fan 1
Single Speed PSC Furnace Fan
0.58
HVAC Fan 1 -hers -fan
HVAC Fan 2
Single Speed PSC Furnace Fan
0.58
HVAC Fan 2 -hers -fan
HVAC FAN SYSTEMS - HERS VERIFICATION
01
02
03 .
Name
Verified Fan Watt Draw
Required Fan Efficiency (Watts/CFM)
HVAC Fan 1 -hers -fan
Required
0.58
HVAC Fan 2 -hers -fan
Required
0.58
BUTTE COUNTY
BUILDING DIVISION
Registration Number: 217-Po10312756B-000-000-0000000-0000 ���fa pie i If�atO11if0e: 2017-11-1714:21:42
CA Building Energy Efficiency Standards - 2016 Residential Compliance ReportVersion - CF1 R-09012017-934 SP1
HERS Provider: CaiCERTS inc.
Report Generated at: 2017-11-17 12:29:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Langerwerf Res Calculation Date/Time: 12:27, Fri, Nov 17, 2017
Calculation Description: Title 24 Analysis Input File Name: T-24 Langerwerf-plancheck.ribdl6x
CF1R-PRF-01
Page 11 of 12
IAQ (Indoor Air Quality) FANS
01
02
03
04
05
06
Dwelling Unit
IAQ CFM
IAQ Watts/CFM
IAQ Fan Type
IAQ Recovery
Effectiveness(%)
HERS Verification
SFam IAQVentRpt
90
0.25
Default
0
Required
PROJECT NOTES
3712 sq ft new residence
C CERTS
, va,
HERS PROV
BUTTE COUNTY
BUILDING DIVISION
APPROVED
n c.
i fl E R
Registration Number: 217-Po10312756B-000-000-0000000-0000 Registration Date/Time: 2017-11-17 14:21:42
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1
HERS Provider: CaICERTS inc.
Report Generated at: 2017-11-17 12:29:25
CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD
Project Name: Langerwerf Res
Calculation Description: Title 24 Analysis
Calculation Date/Time: 12:27, Fri, Nov 17, 2017
Input File Name: T-24 Langerwerf-plancheck.ribdl6x
CF1 R -PRF -01
Page 12 of 12
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1. 1 certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature:
c91teum (2r&cid
Steven Buttitta
Company:
Signature Date:
NorCal GBC
2017-11-17 14:21:42
Address:
CEA/HERS Certification Identification (If applicable):
3385 Neal Rd
CC2006280
City/State/Zip:
Phone:
Paradise, CA 95969
530-828-3221
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3 of the Busin6ss'and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. 1 certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of
Regulations. 1_
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents,
worksheets, calculations, plans and_ specifications submitted ,to -the enforcement.agency,for approvaI.with,this_building permit application.
Responsible Designer Name:i
��•�...,� ��
Responsible Designer Signjatur(e`\
Steven Buttitta ����
Company: i
HERS P
Date Signed:
2017-11-17 V4:21: D E R
NorCal GBC
Address:
License: -
3385 Neal Rd
000000000000001
City/State/Zip:
Phone:
Paradise, CA 95969
530-828-3221
BUTTE COUNTY
BUILDING DIVISION
APPROVED
Digitally signed by Ca10ERTS. This digital signature is provided in order to secure the content of this registered document and in no way implies Registration
Provider responsibility for the accuracy of the information.
Registration Number: 217-P010312756B-000-000-0000000-0000 Registration Date/Time: 2017-11-17 14:21:42 HERS Provider: CaICERTS inc.
CA Building Energy Efficiency Standards - 2016 Residential Compliance Report Version - CF1 R-09012017-934 SP1 Report Generated at: 2017-11-17 12:29:25