HomeMy WebLinkAboutANTI ENTRAPMENT CERTIFICATION FORM FOR SWIMMING POOLS AND SPAS9
Butte County Department of Development Services
PERMIT CENTER
" 7 County Center Drive, Oroville, CA 95965
Main Phone (530) 538-7601 Fax (530) 538-7785
ww%v.bL1tteC0un.tv.ne1-/dds
r
FORM NO
DBP -66
ANTI -ENTRAPMENT CERTIFICATION FORM
FOR SWIMMING POOLS & SPAS
The following form is required whenever a building permit is issued to construct
or repair (re -plastering) a swimming pool, toddler pool, or spa.
STATEMENT TO BE SIGNED PRIOR TO
FINAL APPROVAL
.Verification of Compliance with the "Swimming Pool Safety Act of 2006"
--> (Health & Safety Code 115920 — 115929)
Site Address:
Property Owner:
Owner's Mailing Address:
' Phone:
I hereby certify that the swimming pool, toddler pool, or spa located a the above-
mentioned address complies with the provisions or the "Swimming Pool Safety
Act of 2006" and has been equipped with an anti -entrapment cover meeting
the current ASME/ANSI Standard A 112.19.8 as required under the
provisions of the law and have received additional information ori pool
barrier requirements.
Signed: •
Owner
Signed -
Contractor
Company Name:
Date:
Date:
CONTRACTOR'S INFORMATION
California Contractor's License Number:
Mailing Address:
Phone:
Email:
Attachments: Swimming Pool Enclosure Requirements and Pool Barrier handout
Ppwicprl 7 ?n ?nl 4
Pagel of 3
i
.It
Swimming Pool Enclosure Requirements
Definitions
Approved Safety Pool Cover: A manual or power -operated safety pool cover that meets
all of the performance standards of the American Society for Testing and Materials
(ASTM), in compliance with standard F 1346-91.
Enclosure: A fence, wall or combination thereof that isolates a swimming pool
from unauthorized access.
Exit Alarm: A device that makes an audible, continuous alarm.sound on the doors
leading from the dwelling/garage or other structure to the pool enclosure, which, when
opened or left ajar, permits entry to the pool without any intervening enclosure device.
Exit alarms may be battery operated or connected to the electrical wiring of the
building.
Public Swimming Pool: A swimming pool operated for the use of the general public
with or without charge, or for the use of the members and guests of a private club.
Public swimming pool does not include a swimming pool located on the grounds of a
private single family dwelling.
Swimming Pool or Pool: Any structure intended for swimming, recreational bathing or
other recreational use that will contain water over 18 inches in depth. Swimming pools
include in -ground and above -ground structures and include, but are not limited to, hot
tubs, spas, portable spas and non-portable wading.pools.
Other terms, words, or phrases not defined shall have their ordinarily accepted meanings
within the context with which they are used. Webster's Third New International
Dictionary of the English Language, Unabridged, copyright 1986, shall be considered as
providing ordinarily accepted meanings.
t
Ratricari 7? n ')n1 r Page 2 of
'--!�Swimnung,.Pool Re pirements'
. Drowning'Prevention . Safety 'Features`
Based upon California Health and Safety Code Section 115920-115929, known as the Swimming;
Pool Safety Act •;4 t ' �' " ,
` . ,.The County of Butte requires either a listed; approved safety`pool cover*_'meenng's
ASTM Standard F1346-91, OR a complying enclosure_* which isolates the pool from , +
S the dwelling and remaining yard,OR a complying enclosure*,,which surrounds the perimeter of the pool and dwelling; i4th_ door i
alarms and self-closing, self latching devices on all dors leading into'the enclosure.!
` • *Enclosures r ,,
• Minimum height of 60 inches C '
• Access gates shall open away from pool and have self-closing, self-latching'device no lower
than 60 inches above the ground. , ' '' . -
�, Maximum vertical clearance of 2 inches from the ground to the bottom of enclosure
•, No openings greater than 1/2 inch within 18 inches of the release mechanism when closed.'
Gaps or voids shall not allow the passage of a 4 inch sphere.. t
• Outside surface shall be free of cavities or protrusions that would serve as a foothold or handhold
.` that could enable a child of less than 5 years of age to climb over.
• Maximum mesh size for chain link shall be a 2.25 inch square unless the fence is provided with
slats fastened at the top or bottom which reduce the openings to no more than 1.75 inches .
*Pool Cover
* - • Shall be correctly installed per the manufacturer's instructions to prevent the access of children
under five years of age to the water..
• 'Shall be properly constructed to meet ASTM specifications and be labeled accordingly. -
F • All ties, anchors or attachment points and controls for automatic covers must be installed in a
way to prevent operating or uncovering the poll by children less than five years of age.
• The pool cover shall possess a listing that insures the original design or performance of the cover r'
meets. or exceeds testing as prescribed by ASTM Standard F1345-91 Section 9 Test Methods for
I Safety Covers.
` Door alamis'or self -dosing;:
, self tatctiing doors. �_ . F
• `VJndarrs and doors �,•_�,; -yam- `--�.-� T -Y -_c'`7'' � �c _
' routintay closed and ', '"'L-; ''�F-7---. ��� �'` •• .
latched.
Safety pool
cover.
II . `, r
isolation fence— ! - Galas
,I
t[h i ( I l T' 1i ! 4 ! �l.Y /i,�l ( ;self closin
(I ({ t ! sell latching ,
'Perirrieterfence.- — .. i' i . �' i ;`~�:.•'�' i - '
j , •.♦. n � ' y - �Uli 1, I i i � � � '
.• - � � 4'At a mmfmum eree of{hse shall ba Pravtded'' , �,' - � I `
t ° .. - « T'F .. , - "'.^ ---ter—+i'. •----=r�'..- � r+r_,_� �'1.�r.- .�,i#—... ,
Rt -.vi -,Pd 7.26.201.5 Page 3 of
pool
engineering....
June 27, 2016
Mr. Philo Hunt
County of Butte
25 County Center Dr.
Oroville, CA 95965-3500
Re: Authorization to use Pool Engineering, Inc.
Standard Pool Structural Plan
Dear Mr. Hunt:
By this notice Pool Engineering, Inc. and the undersigned engineer -of -record
shall hereby grant Agua Fina Pools a limited non-exclusive and non -transferable
allowance to utilize Pool Engineering, Inc. Standard Pool structural Plan for the
permitting and construction of the swimming pool project at the Bussey
Residence at 214 Centennial Ave., Chico, CA.
Modification or.reuse of the construction drawings without the express written
permission of the Engineer is prohibited.
If we can be of any further assistance, please do not hesitate to contact us.
Best regards,
Engineer's Seal
004 Engierin Inc.
�odd Lacher, --
This letter is valid only with
engineer's signature in red ink
...
N6.67656
Exp. 6/30117'
1201 N. Tustin Avenue, Anaheim, CA 92807 Fax: (714) 630-6114 Phone: (714) 630-6100