Drawn By;
JKP
Ckd. By:
CJR
Date:
10/24/14
Revision:
2
DRAWING NUMBER
I❑
i
BIOGAS IN
FROM D I GE5TER
0.
89 l
I: COMPRE55ED NATURAL GAS (ONO) SYSTEM (UNISON SYSTEM)
2: FUELING STATION (ANC -,-f GNG SYSTEM)
3: SWITCH GEAR
4: "E" CONDENSATION PUMP (PHASE III)
5.: "E" TRUCK RAMP (PHASE 1)
6: (1) "N" 4" PVC 5GH40 ELECTRICAL CONDUIT
7: (2) "N" 4" PVC 5GH40 SPARE ELECTRICAL CONDUIT
a: (1) "N" 6" UNDERGROUND HDPE100 GAS PIPE
G: (1) "N" 4" UNDERGROUND HI7PE100 GAS PIPE
10: (3) "N" 2" PVG 5GH40 SPARE COMMUNICATION LINE CONDUIT
11: (1) "N" 2" PVG SCH40 WATER LINE (CONNECT "E" ONSITE
POTABLE WATER TO "E" PHASE III WATER LINE)
12: (2) "N" 3" GALVANIZED RIGID CONDUIT (CRC) TO "E" SERVICE
PANEL
13:ANG1 FUEL DISPENSER
14-UN15ON GLYCOL CHILLER
15:GNG CONTROL PANELS - ELECTRICAL PANEL
"NOTES:
I. ALL PIPING SHALL BE PRESSURE TESTED a 6Opsi PRIOR TO
PROCESS INITIATION.
2. SEE TRENCH DETAIL I/PI.
PLUMB I NO/E-LEGTR I GAL. PLAN
GNC SYSTEM GOMFONEN T5 UNISON I FUELING STATION COMPONENTS ANSI
COMPRESSOR AND DRYER
BIOGAS GLEANING/
DRYER
14'Lx5'Wxl2'H
PSA SKID
&'Lx5'Nx 14'H
0'Lx0'Nx14'H
PHASE IV
PHASE IV
PHASE IV
TAIL GAS
TO DIGESTER
CHILLER CONTROL PANEL5 ELECTRICAL PANEL
10'Lx4.5' Nx6.7'H 55Lx25IWx&'H 4'Lx25Wx5'H
PHASE IV PHASE' IV PHASE IV
GNG GOMPRE55OR
I O'Lx5'Wx5'H
PHASE IV
13 \ \
\ \ 1
g \ \
8 \\
--\ \ \\
7 0 6
GNG STORAGE
14'Lx6'Wx,5'H
PHASE IV
PRIORITY PANEL
4'Lx 1.5'Wx6'H
PHASE IV
GNG DISPENSER
5.5'Lx I.25'Wx7.3'H
PHASE IV
6'ERMrr /y 2 yG Z
t.
Z W
z++
_ pm
�ZW. WN W +�Wu+�~QQW
Zat= 0! �Z�Z0ZaZ
WF -Vi-Z-xdn'=OZW<*
z
�o o�ap�
�v aWWZ�a�zu.0` ZW
mays==Q=�ZaV -jQp0
tJfQ'�F-WOC mW W m0-�W0
ZWZZX0=�.0W0X . 3tW-
0 403 .® ;zp3WeQ
ujWzz<`0-vf-O�W�=z
00m02WE OZ t°4aw Ix- Zmm Ow
CCpLLVvf° F-vf V pdQ0�4Q
2
W
F
lom
Z
V
•
M
a co
V ct
O 00`0 E
0
UP
Lflj 4)
.. V
Q a Sr
r N.
Q? e
� M �
00 CL
i� �
a=
IV
(DCO
^E
M 0
OL V
�, %
P
a�
O = i
0 -c
V) a
Drawn By: JKP
Ckd. By: CJR
Date: 10/'24/14
Revision: 2
DRAWING NUMBER
Ip 2
REMOVE AFTER GENERATOR SERVICE IS COMPLETE
PHASE 2
PG+E OVERHEAD
PG+E CUTOUTS
PG+E TRANSFORMER
PADMOUNT 480/277V
PHASE 2
RENDER PLANT
PG+E FEED TO BE
DISCONNECTED
(8)-5"C PG+E SECONDARY
PHASE 1
BIOGAS POWER FROM RENDER PLANT
CNG POWER FROM RENDER PLANT
RENDER PLANT POWER FROM PG+E
UTILITY METER
PG+E
— KWH EXISTING RENDERING PLANT MAIN SERVICE
MSt 2000A, 480/277V, NEMA 3R 65K AIC
8000l 250 nl 225 ^l 200 ^l
DIST PANEL
DP1
800A, 480/277V
RENDER PLANT N
SKINNING RM MCC
MCC3
225A, 480V
PHASE 1 600A 480/277V (TEMP)
FEED FROM RENDERING PLANT
(2)-4"C 3-500MCM AL, 350MCM AL N, #1/0 AL G
PHASE 2 (FUTURE FEED TO RENDER PLANT)
(6) MAIN BREAKERS
250 vl
n
BIG GRINDER
GR5
250A, 480V
800 vl
n
1000A 480/277V (FUTURE) PHASE 2
FEED FROM DIGESTER MAIN SERVICE
(3)-4"C 3-500MCM AL, 350MCM AL N, #4/0 AL G
600 vl
� TP1 CNG TIE PANEL
1000A, 480/277V
NEMA 3R 35K AIC
400 nl 150 ^l
4"C 6-350MCM ALI #1/0 AL G
CNG DIST PNL DP4
PI JMP� + nnmTM,
400A 480V NEMA -3R 35K AIC
200 vl 150 v 50/2 V
J
3-250MCM AL ,1 #6 CU G
3—#3/0 AL I, #6 CU G
PHASE 1
DIGESTER MCC 3
PUMPS + CONTROL
400A 480/277V
(TEMP PWR)
3-250MCM AL , #6 Co G
TX 4C
GROUND AND BOND AS PER NEC
INCLUDING:
#6 TO 10'x5/8" CU CLAD GND ROD
#6 COPPER TO DP4 GND BUS
0
E
O
►n "�4
CO"14
�
N0
C:
Q
U
C
o
o
^a
U)
W
°
C"
a
`
r01r'0-
Lo0
a
r'L
LO
O
L0
O,
N
o
m
IL
H
ELECTRICAL NOTES
USES PNL BOILER NEW PLANT CNG MCC 4 1 " C 2#8, #8G
1. ALL WIRE THHN/THWN COPPER
DP2 TRUCK SHOP MCC6 200 COMPR, DRYER UNLESS NOTED OTHERWISE 250A, 480V 200A, 480V 800A, 480V 150 DISPENSER 95A
I---
2. MINIMUM POWER WIRE SIZE #12
#14 FOR CONTROL
,ANGI COMPRESSOR PWR PNL Q
UNLESS NOTED OTHERWISE
ATMI UNISON PNL 150A 480V —i
3. CONDUIT TO BE GRC UNLESS NOTED OTHERWISE GAS CONDITIONING CL
PVC MAY BE USED UNDERGROUND -
4. INSTALLATION TO MEET ALL LOCAL CODES AND NEC COMPLY WITH CALLFORK4 122A 480V TX 4C Q
5. ALL CIRCUIT BREAKERS SHALL BE LEGIBLY AND ELECTRICAL CODE-AR77CLE250 CNG MCC 5 25 25 KVA z n-,
DURABLY MARKED. REQUIREMENTS FOR GROUNDING / 35 480 TO 12 /240V
/ Q
Q
6. OUTDOOR ENCLOSURES TO BE NEMA -3R 600A 480/277V (TEMP CNG) PHASE 1 AND BONDING INCLUDES: Tx�
VAC PUMP 5 KVA L
RAINTIGHT _ _
48a To ,
7. ALL SWITCH AND OUTLET BOXES TO BE MOUNTED FEED FROM RENDERING PLANT HILLER ,240 z
BETWEEN 16" AND 48" ABOVE FLOOR ELECTRICAL EQUIPMENT LLJ W
UNLESS OTHERWISE NOTED (CONTINUED AT RIGHT) INSTALLED IN WET LOCATIONS 50 1 .25" C 3#2, #8G 1h z
SHALL BE IDENTIFIED & LISTED —
8. ALL ELECTRICAL WORK TO COMPLY WITH 2002 NEC FOR WET LOCATIONS PER CEC 0 J
ARTICLE 100 & 110.11 12 CIRCUIT z LLJ
9. ALL RACWAYS MOUNTED ON ROOF TO BE DERATED FOR TEMP AS PER 120V —
NEC 310-16 CORRECTION FACTORS FOR 110 DEG F I— �
COMPLY WITH CALIFORNL4 ELECTRICAL 1021/2
10. DERATE WIRE AS PER NEC 310-15 (B)2 FOR MORE THAN CODE -for wiring methods- secure 0 X z
3 CURRENT CARRYING CONDUCTORS PER CONDUIT conductors and conduit per all applicable w (J�
requirements as required by the 2013 CEC for
the specific method of wiring 30
SCALE
Label, circuit breaker(s), disconnect(s), COMPRESSOR NONE
fuse(s),switch(es) and their 50 HP ANGI DRYER DATE
accessories, to identify their location LP 4C 7/29/ 14
and or equipment 100A 120/240V REV No REV BY
CNG AREA REVDATE 1
Provide readily accessible capability to 1 0/29/ 14
DRAwN
circuit breaker(s), disconnect(s), - �-Z--
PERMIT # JO
Fuse(s),switch(es) and their accessories BUTTE ^Ok.W .S
DWG NO
as required :a:Jj defined in California
E4 r s 13-05A
Electr r.:µ Code
PATE `< S/11�✓"--- - ----- — SHEET NO
................ . ........... E
2
..........:........................................_............................._..................................................
......... .....
►n "�4
CO"14
�C\j
rnN
�I
LL j
�n
C"
�
o
a
0 �-
D E
H
�CV)
1,_4 W
Co
a
to
cu
P4
�a
Q
U
CD
z
L,J
0
W
Li
<C
W
Q
U
W
� n
07
n
__j
-F
__j
I— (�
>
o
C Ln
rz
z7 —
0
ELECTRICAL NOTES
USES PNL BOILER NEW PLANT CNG MCC 4 1 " C 2#8, #8G
1. ALL WIRE THHN/THWN COPPER
DP2 TRUCK SHOP MCC6 200 COMPR, DRYER UNLESS NOTED OTHERWISE 250A, 480V 200A, 480V 800A, 480V 150 DISPENSER 95A
I---
2. MINIMUM POWER WIRE SIZE #12
#14 FOR CONTROL
,ANGI COMPRESSOR PWR PNL Q
UNLESS NOTED OTHERWISE
ATMI UNISON PNL 150A 480V —i
3. CONDUIT TO BE GRC UNLESS NOTED OTHERWISE GAS CONDITIONING CL
PVC MAY BE USED UNDERGROUND -
4. INSTALLATION TO MEET ALL LOCAL CODES AND NEC COMPLY WITH CALLFORK4 122A 480V TX 4C Q
5. ALL CIRCUIT BREAKERS SHALL BE LEGIBLY AND ELECTRICAL CODE-AR77CLE250 CNG MCC 5 25 25 KVA z n-,
DURABLY MARKED. REQUIREMENTS FOR GROUNDING / 35 480 TO 12 /240V
/ Q
Q
6. OUTDOOR ENCLOSURES TO BE NEMA -3R 600A 480/277V (TEMP CNG) PHASE 1 AND BONDING INCLUDES: Tx�
VAC PUMP 5 KVA L
RAINTIGHT _ _
48a To ,
7. ALL SWITCH AND OUTLET BOXES TO BE MOUNTED FEED FROM RENDERING PLANT HILLER ,240 z
BETWEEN 16" AND 48" ABOVE FLOOR ELECTRICAL EQUIPMENT LLJ W
UNLESS OTHERWISE NOTED (CONTINUED AT RIGHT) INSTALLED IN WET LOCATIONS 50 1 .25" C 3#2, #8G 1h z
SHALL BE IDENTIFIED & LISTED —
8. ALL ELECTRICAL WORK TO COMPLY WITH 2002 NEC FOR WET LOCATIONS PER CEC 0 J
ARTICLE 100 & 110.11 12 CIRCUIT z LLJ
9. ALL RACWAYS MOUNTED ON ROOF TO BE DERATED FOR TEMP AS PER 120V —
NEC 310-16 CORRECTION FACTORS FOR 110 DEG F I— �
COMPLY WITH CALIFORNL4 ELECTRICAL 1021/2
10. DERATE WIRE AS PER NEC 310-15 (B)2 FOR MORE THAN CODE -for wiring methods- secure 0 X z
3 CURRENT CARRYING CONDUCTORS PER CONDUIT conductors and conduit per all applicable w (J�
requirements as required by the 2013 CEC for
the specific method of wiring 30
SCALE
Label, circuit breaker(s), disconnect(s), COMPRESSOR NONE
fuse(s),switch(es) and their 50 HP ANGI DRYER DATE
accessories, to identify their location LP 4C 7/29/ 14
and or equipment 100A 120/240V REV No REV BY
CNG AREA REVDATE 1
Provide readily accessible capability to 1 0/29/ 14
DRAwN
circuit breaker(s), disconnect(s), - �-Z--
PERMIT # JO
Fuse(s),switch(es) and their accessories BUTTE ^Ok.W .S
DWG NO
as required :a:Jj defined in California
E4 r s 13-05A
Electr r.:µ Code
PATE `< S/11�✓"--- - ----- — SHEET NO
................ . ........... E
2
..........:........................................_............................._..................................................
......... .....
I
/
/
/ NEW OVERHEAD 12KV
/ PG+E NEM
/
I / FUTURE
/ PHASE 2
/
/ 12KV POLEMOUN'
PG+E DISCONNE(
PG+E NEM
/ UNDERGRI
\ 5" PVC A
PG+E OVERHEAD 60KV 12KV \
I 12KV ESQUON 102171101 / \
POND \
/ MS2 1600A 480\ 277'
GENERATOR SERV
/
/ POND
POND / (E) TO BE DISCONNECTED
/ PG+E TX
/ MOB E HOME
PADMOUNT TRANSFORMER,''
PAD, GUARDPOSTS
O PG+E NEM �g
/ (2) 3" GRC TP1 1000A 480/277V
TO (E) SERVICE NEMA 3R PULL BOX TIE PANEL
I / / 36 X 30 X 12 PAD, GUARDPOSTS
/ (2) 4" PVC r �\
DP4 400A 480V
/\ \ SHOP \\ CNG DIST PNL
CNG DISC 1-1
7v MS1 OOOA 480/27 v \ /
/ CNG SC EXIST G MAIN SER ICE \ \
\�48
ONC PULL BOX
RENDERI G PLANT OR SIMILAR O
PROTECT FROM TRAFFIC CNG EQUIF
/
/
/
/ OFFICE
0) /
U
Lv
SHIPPEE RD
Im
BIOMASS DIGESTER
GENERATOR 0.7 MW
E ;,�iTE J*, 4"Y Pr V-i_OPMENT SERVICES
D
tEVIEVI D FOR
Zl//
ELECT SITE PLAN
SCALE APROX
V1 = 50'
11X17 IS REDUCED PLOT - ORIGINAL IS 24X36
C
O
U
ti
ccyi
L1�
c� .4
�c\j
(D
p
Q
U
c
so
Li j
o
�_0
U)
w
U
0
U
z
w
U)
C.0
r --
U~
CL
Lo
O
o�
D E
d 0
o
0m
N
o
EL
a
NOTED
�m
00
Iy
O
c� .4
�c\j
Q
M c\j
LLJLi
Li j
U
U
cv
U
z
w
'-+
•d
U~
CL
o ..,
E4
O
D E
d 0
SCALE
a
NOTED
�m
00
9/25/13
REV NO
13 B
a,
10/29/14
DRAWN
U p
DWG NO
co U
CD
13-05B
SHEET NO
U
z
CL
w
z
w
w
Q
w
Q
U
W
�
F— u5
Q:�
Q
O Lo
n--,
z c-
.o
Iy
O
Q
r
LLJLi
U
r-)
z
w
Q
O
CL
IL
O
w
SCALE
NOTED
DATE
9/25/13
REV NO
13 B
1 _
REVDATE
10/29/14
DRAWN
JO
DWG NO
13-05B
SHEET NO
E3
NOTE.- VALVES AND FLANGES OF
SCREWED FITTINGS - UNCLASSIFIED
15 FT
Cl D2 (ALL AROUND
ANCILIARY EQUIPMENT)
CLEAR TO FLAMMABLE
OR CUMBUSTABLE LIQUIDS
CLEAR TO ALL �20 FT
ELECTRICAL INSTALLATIONS
---
Fll5 FT
Cl D2
DRYER
FUELING EQUIPMENT COMPOUND AREA
� (NO POWER LINES OVERHEAD)
COMPRESSOR SKID
Cl D2
10 FT
CLEAR TO PROPERTY LINES,
BUILDINGS, OR ANY SOURCE
OF IGNITION
10 Fr
CLEAR TO PUBLIC STREET
OR SIDEWALK LINE
NOTE 1: OTHER CODES AND REGULATIONS MAY APPLY
NOTE 2: REFERENCE ONLY -FINAL SITE DESIGN BY OTHERS
NOTE 3: CONSULT NFPA 30A FOR ADDITIONAL SITE REQUIREMENTS OR
CLEARANCES IF CNG REFUELING AT A SITE WHERE OTHER
TRANSPORTATION FUELS ARE BEING DISPENSED OR STORED.
B 06FE812 ADDED NOTE 3 AND DISPENSER ESD NOTE
GT
A 02FE812 UPDATED POINT OF TRANSFER
DH AND ASSOCIATED DIMENSIONS
REV I DATE BY I DESCRIPTION REV I DATE BY DESCRIPTION
CLEAR TO READILY
IGNITABLE MATERIAL
Cl D2
(ALL AROUND CONTAINERS)
COMPRESSOR SKID �
Cl D2 �
Cl D2
(ALL AROUND
15 FT COMPRESSOR)
5 FT
C1 D1
50 FT
CLEAR TO DISPENSING �
DEVICES WITH LIQUID OR \
GASEOUS Fi
5-15 FT \
Cl D2
-ALL RELIEF VALVES OR VENT (NP.)
(ALL DIRECTIONS FROM POINT SOURCE)
NOTE: VENTING TO ATMOSPHERE
GENERALLY OCCURS AT COMPRESSOR,
STORAGE, ANCILIARY EQUIPMENT, AND
OCCASSIONALLY AT THE DISPENSER
NOTE: DISCHARGE FROM RELIEF VALVES
WITHIN 15 DEGREES OF LINE OF DISCHARGE
IS C1D1 UP TO 15 FT
5
50 FT
CLEAR TO RAILROAD TRACKS
.Jives v IL-rr
DEFINITIONS: (REF. OSHA HAZARDOUS (CLASSIFIED) LOCATIONS
C 1 D 1- CLASS 1, GROUP D, DIVISION 1
CLASS 1: GASES, VAPORS, AND LIQUIDS (ART. 501)
GROUP D: HYDROCARBONS, FUELS, SOLVENTS, ETC.
DIVISION 1: NORMALLY EXPLOSIVE AND HAZARDOUS
Cl D2 - CLASS 1, GROUP D, DIVISION 2
CLASS 1: GASES, VAPORS, AND LIQUIDS (ART. 501)
GROUP D: HYDROCARBONS, FUELS, SOLVENTS, ETC.
DIVISION 2: NOT NORMALLY PRESENT IN AN EXPLOSIVE
CONCENTRATION (BUT MAY ACCIDENTALLY EXIST)
CLEAR TO ALL SOURCES OF IGNITION
CLEAR TO BUILDINGS, MOBILE HOMES
CLEAR OF
10 FT PUBLIC SIDEWALKS, STREETS, OR ROADS
STORAGE
CONTAIN
Aviv iruiv�nJ
3 FT � FUEL MANAGEMENT
PEDESTAL (OPTIONAL)
POINT OF TRANSFER
CNG RECEPTArI 17"
PERMIT # i/y-upb/ L
BUTTE COUNTY DEVELO[` � r 7--VICES
REVIEWEC -CCK _
CODE CO P,
DATE
NOTE: SECTION 8.11.5 AN
EMERGENCY MANUAL SHUTDC
DEVICE SHALL BE PROVIDED
WITHIN 10 FT. OF THE
DISPENSING AREA AND ALSO
GREATER THAN 25 FT. FRON
5 FT MIN
xA
Y
5 FT
Cl D2
LL AROUND"'
K
)ISPENSER),
THE DISPENSING AREA.
J10 FT P
V-0 Iu2 AREA
ANGI ENERGY SYSTEMS UNLESS OTHERWISE SPECIFlED TITLE
15 PLUMB STREET -CE1
MILTON, WI 53563
Lry PH: 608-868-4626 BREAK SHARP EDGES CUSTOMER
=NERGY SYSTEMS FX: 608-86e-2723 ALL DIMENSIONS IN INCHES
FACTRIONAL 1.125 SHEEP
THIS DRAWING AND ALL INFORMATION THEREIN IS THE SOLE PROPERTY OF ANGI TWO PLACE DECIMAL 1.010
AND SHOULD NOT BE COPIED, REPRODUCED, OR SUBMITTED TO OTHERS WITHOUT THREE PLACE DECIMAL f.005 DRAWN BY
WRITTEN AUTHORIZATION. ALL REPRODUCTIONS ARE SUBJECT TO RETURN ON DEMAND. ANGLES t1'
CLEAR TO BUILDINGS, MOBILE HOMES,
PUBLIC SIDEWALKS, STREETS, OR ROADS
NFPA 52 - 2013 EDITION (SECTION 8.4.2)
OUTDOOR CLEARANCES FOR CNG FUELING EQUIPMENT
PROJECT N0.
1 /1 SCALE NA DRAWING N0.
DH DATE 09 FEB 11 Z-1009
REV.
B
WINDCHILL
ME
Phase IV of North State Rendering's Biogas Project
CNG equipment installation
Biogas produced by the anaerobic digester consists of 65% CH4 (methane) and 34%
CO2. In order to use biogas as a fuel in trucks, CH4 content must be —98%, and the
gas must be compressed. The current permit is for the installation of equipment
that cleans up the Biogas to ^-98% CH4, compresses it, and dispenses it to North
State Rendering's trucks.
Previous document submittal included unnecessary plans for the equipment itself.
After meeting with county staff, Biogas Energy is submitting the attached
documentation.
This phase of the project encompasses the installation of equipment that
1) cleans biogas supplied from the digester into pipeline quality natural gas
(UNISON system)
2) compresses and dispenses the Compressed Natural Gas (CNG) for truck fuel
(ANGI system)
Biogas is fed from the digesters via underground pipe to the UNISON system
comprised of:
1) biogas dryer - compressor skid
2) Pressure Swing Absorption (PSA) biogas cleanup skid
3) Glycol chiller (for the biogas dryer)
From the UNISON system, the cleaned natural gas is piped to the ANGI system, while
the off gas (consisting of 85% CO2 and 15% CH4) is piped back to the digester to be
mixed with new biogas being produced.
The ANGI system is comprised of
1) biogas dryer skid
2) biogas compressor skid
3) 3 storage tanks
4) CNG dispenser
The dispenser is used only by North State Rendering and is not available to the
public.
An electrical panel supplying electricity to the equipment is supplied by Layman
Electric. q,trt,
PERMIT
BUTTE CnuNrr-,, CkVELOPM -NT SERVICES
EWER FOR
CODE i PLIANCE
DA7�._. _ I BY U