HomeMy WebLinkAboutB15-0042 047-020-014PV -01 PV -02 PV -03 PV -04 PV -05 PV -06 PV -07 PV -08 (E) (N) GND PNL J -BOX MSP PVC EMT FMC NEMA SHEETINDEX TITLE SHEET SITE PLAN ARRAYLAYOUT ELECTRICAL DIAGRAM ELECTRICAL DIAGRAM ELERCTRICAL CALCULATIONS EQUIPMENT LAYOUT SIGNAGE ABBREVIATIONS EXISTING NEW. GROUND PANEL BOARD OR PANEL JUNCTION BOX MAIN SWITCH PANEL r POLYVINYL CHLORIDE ELECTRIC METAL TUBING FLEXIBLE METAL CONDUIT NATIONAL ELECTRIC MANUFACTURES ASSOCIATION VICINITY MAP SYSTEM INFORMATION PROPERTY OF Elite Solar 34 �.�� SYSTEM SIZE: 2.36 KWDC '�' �' :• r a "s � � ' � �q,' rr"• ALL DESIGN PARAMETERS MUST BE CONFIRMED c h ,�a;1,V;. "�k a �_" , A• �_� PV MODULE: (756) CANADIAN SOLAR CS6X-310P AND ADJUSTED TO MEET SITE SPECIFIC mpg CONDITIONS OF USE. INSTALLING DEALER HAS 'CREOTECC WITH PROTEA BRACKETS SOLE RESPONSIBILITY FOR THE CORRECT 3 r 3 ., �,. ;, .� • • , � • � >��4 r SELECTION AND INSTALLATION OF ALL ABB TRIO-27.6-TL-OUTD-S2F-400 EQUIPMENT AND MATERIALS TO MEET ANY POWER PRODUCTION COMMITMENTS AND ALL .� SCOPE OR WORK LOCAUNATIONAL CODE AND SAFETY e ' • 0 �' REQUIREMENTS. t•_ " 4,rYiS=r# INSTALLATION CONSISTS OF (756) CANADIAN SOLAR CS6X-310P PV - j MODULES, (8) ABB TRIO-27.6TL INVERTERS, AND RELATED - w c» ELECTRICAL METERING (IF USED) AND SAFETY EQUIPMENT. •,�, q.. 4t � 111 ♦ • ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE- .. WARRANTED. �► !�+►' } �' � � • ALL EQUIPMENT WILL BE INSTALLED AS REQUIRED BY APPLICABLEElite Sour rrt " CODES AND -LOCAL UTILITY_ COMPANY REQUIREMENTS. 4 Owner:: 1-.1 C h , a 15 PEPSI WAY. I DURHAM, CA 95938 APN: 17r OLQ— wq r= -�-� . s• Date• -3 L � �' .. . ; (530) 345-9910 WWW. ELITESOLARCA:COM FILE? OV CSLB # 930561 C46 -� T., r� PROJECT INFORMATION - 6UT- £ G'CLINTY DEVELOPMENT SERVIOES NAME: PINE CREEK RANCH _ _ _ ADDRESS: 7020 CANA HWY • ."r. .,'.,•.sA � - - _ - - _V11 WED I=0P -- CITY: CHICO, CA 95926 s f.iODE COMPLI) NCE -y,, • PHONE: r TZ %� t AHJ: BUTTE COUNTY Jl / By G`� I A#: 047L02010140000 CONSTRUCTION NOTES D ---.�_ _ RN .I �t � ( ^(,f� � PROJECT#: • A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS r • THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY GRID INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. • THE SOLAR PV INSTALLATION SHALL NOT,OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. • A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690-47 AND 250-50 THROUGH 60 250-166 SHALL BE PROVIDED. PER NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A 6 SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE GROUND. • EACH MODULE WILL BE GROUNDED USING THE SUPPLIED GROUNDING POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION MANUAL. • EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. • PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION 110.26 CEC.` • ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC, ENGRAVED IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED USING AN APPROVED METHOD. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. • ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY 2013 CEC AND 2011 NEC. ' • HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC 240.24. • THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER NEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER NEC 250.64C. i • ALL EXTERIOR CONDUIT SHALL BE PAINTED TO MATCH ADJACENT SURFACES. • SITE CONDITIONS SHALL PREVAIL. IF NO SCALE IS GIVEN, DRAWINGS ARE NOT TO SCALE. ALL DIMENSIONS SHALL B EBIED BY SUBCO= OR ANDC'UBCONTRACTORS IN THE FIELD UPON COMMENCEMENT OF CONSTRUCTION. k _ } i se e /9P�Na�'Q Finished Construction Flood Elevation Certificate required Ip�h fy�o� Prior to final building inspection i AHJ SIGNATURE AND DATE I I REVISION SCHEDULE I No. Date Description 1 03/16/15 Submittal t DRAWN BY: ICK APPROVED BY: I DR DATE: 03/16/15 SHEET TITLE TITLE SHEET SHEET NUMBER PV -01 i t inch Scale to Confirm 11"x17" Plot ©Copyright 2014, Elite Solar d le r r -1 v %.efl ,M SYMBOLS KEY EQUIPMENT MANUFACTURERS OMETER 1 •� Rs -•+� �(a)� INVERTER GROUND SWITCH FUSE BREAKER CONDUIT RUN EXTERIOR CONDUIT RUN INTERIOR INTERNET PHOTOVOLTAIC MODULES: CANADIAN SOLAR (US), INC. 2420 CAMINO RAMON, SUITE 125 SAN RAMON, CA 94583 (888) 998-7739 RACKING: CREOTECC SOLAR MTG SYSTEMS 15 PEPSI WAY DURHAM, CA 95938 (530) 345-9910 INVERTER: ABB VICINITY MAP SYSTEM INFORMATION PROPERTY OF Elite Solar 34 �.�� SYSTEM SIZE: 2.36 KWDC '�' �' :• r a "s � � ' � �q,' rr"• ALL DESIGN PARAMETERS MUST BE CONFIRMED c h ,�a;1,V;. "�k a �_" , A• �_� PV MODULE: (756) CANADIAN SOLAR CS6X-310P AND ADJUSTED TO MEET SITE SPECIFIC mpg CONDITIONS OF USE. INSTALLING DEALER HAS 'CREOTECC WITH PROTEA BRACKETS SOLE RESPONSIBILITY FOR THE CORRECT 3 r 3 ., �,. ;, .� • • , � • � >��4 r SELECTION AND INSTALLATION OF ALL ABB TRIO-27.6-TL-OUTD-S2F-400 EQUIPMENT AND MATERIALS TO MEET ANY POWER PRODUCTION COMMITMENTS AND ALL .� SCOPE OR WORK LOCAUNATIONAL CODE AND SAFETY e ' • 0 �' REQUIREMENTS. t•_ " 4,rYiS=r# INSTALLATION CONSISTS OF (756) CANADIAN SOLAR CS6X-310P PV - j MODULES, (8) ABB TRIO-27.6TL INVERTERS, AND RELATED - w c» ELECTRICAL METERING (IF USED) AND SAFETY EQUIPMENT. •,�, q.. 4t � 111 ♦ • ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE- .. WARRANTED. �► !�+►' } �' � � • ALL EQUIPMENT WILL BE INSTALLED AS REQUIRED BY APPLICABLEElite Sour rrt " CODES AND -LOCAL UTILITY_ COMPANY REQUIREMENTS. 4 Owner:: 1-.1 C h , a 15 PEPSI WAY. I DURHAM, CA 95938 APN: 17r OLQ— wq r= -�-� . s• Date• -3 L � �' .. . ; (530) 345-9910 WWW. ELITESOLARCA:COM FILE? OV CSLB # 930561 C46 -� T., r� PROJECT INFORMATION - 6UT- £ G'CLINTY DEVELOPMENT SERVIOES NAME: PINE CREEK RANCH _ _ _ ADDRESS: 7020 CANA HWY • ."r. .,'.,•.sA � - - _ - - _V11 WED I=0P -- CITY: CHICO, CA 95926 s f.iODE COMPLI) NCE -y,, • PHONE: r TZ %� t AHJ: BUTTE COUNTY Jl / By G`� I A#: 047L02010140000 CONSTRUCTION NOTES D ---.�_ _ RN .I �t � ( ^(,f� � PROJECT#: • A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS r • THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY GRID INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. • THE SOLAR PV INSTALLATION SHALL NOT,OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. • A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690-47 AND 250-50 THROUGH 60 250-166 SHALL BE PROVIDED. PER NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A 6 SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE GROUND. • EACH MODULE WILL BE GROUNDED USING THE SUPPLIED GROUNDING POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION MANUAL. • EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. • PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION 110.26 CEC.` • ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC, ENGRAVED IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED USING AN APPROVED METHOD. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. • ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY 2013 CEC AND 2011 NEC. ' • HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC 240.24. • THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER NEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER NEC 250.64C. i • ALL EXTERIOR CONDUIT SHALL BE PAINTED TO MATCH ADJACENT SURFACES. • SITE CONDITIONS SHALL PREVAIL. IF NO SCALE IS GIVEN, DRAWINGS ARE NOT TO SCALE. ALL DIMENSIONS SHALL B EBIED BY SUBCO= OR ANDC'UBCONTRACTORS IN THE FIELD UPON COMMENCEMENT OF CONSTRUCTION. k _ } i se e /9P�Na�'Q Finished Construction Flood Elevation Certificate required Ip�h fy�o� Prior to final building inspection i AHJ SIGNATURE AND DATE I I REVISION SCHEDULE I No. Date Description 1 03/16/15 Submittal t DRAWN BY: ICK APPROVED BY: I DR DATE: 03/16/15 SHEET TITLE TITLE SHEET SHEET NUMBER PV -01 i t inch Scale to Confirm 11"x17" Plot ©Copyright 2014, Elite Solar d le r r -1 v %.efl ,M F 04 -' PROPERTY LINE (TYP) w w U Z_ a. '} • I l\ I , I � • I I I _ EXISTING STRUCTURES 1 - • • I V-03 I I 673,7 iql 2390' , CANA HWY SYSTEM INFORMATION: PROPERTY OF ADDRESS: Elite Solar • (792) CANADIAN SOLAR 31 OW ALL DESIGN PARAMETERS MUST BE CONFIRMED • (8) ABB TRIO-27.6-TL-OUTD-S2F-400 AND ADJUSTED TO MEET SITE SPECIFIC AHJ: CONDITIONS OF USE. INSTALLING DEALER HAS INVERTERS SOLE RESPONSIBILITY FOR THE CORRECT PROJECT#: SELECTION AND INSTALLATION OF ALL TOTAL SYSTEM SIZE: 245.52 kWDC EQUIPMENT AND MATERIALS TO MEET ANY POWER PRODUCTION COMMITMENTS AND ALL LOCAUNATIONAL CODE AND SAFETY REQUIREMENTS. � f Elite Sola*r 15 PEPSI WAY DURHAM CA 95938 PFRf 10— SU'!TE COUNTY DEVELOPMENIT SERVICE REVIEWED FOR Co® PLIANCE- DATES Z r_I.�Y 1 180° True 0 600' 1200' 2400' Scale: 1" = 1200' { (530) 345-9910 WWW.ELITESOLARCA.COM CSLB # 930561 C46 PROJECT INFORMATION NAME: PINE CREEK RANCH ADDRESS: 7020 CANA HWY CITY: CHICO, CA 95926 PHONE: AHJ: BUTTE COUNTY APN#.. 047L 0201 014U 000 PROJECT#: AHJ SIGNATURE AND DATE I REVISION SCHEDULE No. Date Description 1 03/16/15 1 Submittal t DRAWN BY: CK APPROVED BY: DR DATE: 03/16/15 SHEET TITLE SITE PLAN SHEET NUMBER PV -02 r 1 inch Scale to Confirm 11"x17" Plot ©Copyright 2014, Elite Solar WILDFIRES IN BUTTE COUNTY move vegetation and debris from ier and away from structure. intain clearance for a fire safe'. rironment. KEEP .IFORNIA GREEN SHOP \\ \ \ EXISTING STRUCTURE \ �\ PROPERTY LINE (TYP) y HIGH WATER LINE OF PINE CREEK \ \ \ 60'-5" \ \ \ \\ \\ \ \ Flood Zon®'_.A:— j \\ \\ �F.LR.M.: 300 F, 33' \ \ MIN. 50' FR7 HIGH WATERLINE Typ. \ \ \ \ PERIVII7 -/!/- � y� \ \ \ SU tT'E COUNTY p�ry%ELOEMENT SERVICES € E�/lEWE® FOR 184'-3" \� \\ \ C®®E C \ \ \ DATE �P!/'�! V �, E 1 30' 331' \\ \\ \ 118'-3" \ (E) VW'F\LL \ 50' v v \ \ \ 790' TO \ \ \ \ CANA HWY \ \ RESIDENCE \ \ (E) SEPTIC TANK WITH \ \ LEACH LINES \ \ EXISTING STRUCTURE \ \ 0 25' 50' 1-100, (E) WELL Scale: 1" (For 11x17 Print) \ \ PROPERTY OF Elite Solar ALL DESIGN PARAMETERS MUST BE CONFIRMED AND ADJUSTED TO MEET SITE SPECIFIC CONDITIONS OF USEANSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT SELECTION AND INSTALLATION OF ALL EQUIPMENT AND MATERIALS TO MEET ANY POWER PRODUCTION COMMITMENTS AND ALL LOCAUNATIONAL CODE AND SAFETY REQUIREMENTS. f. a{: p 4 +40 0 4110 4ti 4i. a �*41 E I ite. ;polar 15 PEPSI WAY DURHAM, CA 95938 (530) 345-9910 WWW.ELITESOLARCA.COM CSLB # 930561 C46 PROJECT INFORMATION I NAME: PINE CREEK RANCH ADDRESS: 7020 CANA HWY CITY: CHICO. CA 95926 PHONE: AHJ: BUTTE COUNTY APW.. 047L 0201 014u 000 PROJECT#: AHJ SIGNATURE AND DATE REVISION SCHEDULE No. Date Description 1 03/16/15 Submittal DRAWN BY: I CK APPROVED BY: I OR DATE: 03/16/15 SHEET TITLE ARRAY LAYOUT SHEET NUMBER PV -03 1 1 inch 1 Scale to Confirm 11"x17" Plot ©Copyright 2014, Elite Solar TAG DESCRIPTION COMPONENT COMMENTS O1 STRING OF PV MODULES IN SERIES CANADIAN SOLAR CS6X-310P See Electrical Diagram for number of PV Modules per String O INVERTER - 1 THRU 4 ABB TRIO-27.6-TL-OUTD-S2F-400 O3 SOLAR LOAD CENTER "ACCA" 200A, 480V, 313h, 3W, 200A MAIN BREAKER 1 I Inverter DC INVERTER#1 isconned 3 . I MPPT1 6 STRINGS OF I 18 MODULES EACH. 15A I ' l MID 1 ' 3 t (N) SOLAR LOAD CENTER "ACCA" ' r--------- ---- --- -- Co— _---___— ---� 200A,480V,3e,NEMA 3R _j I Inverter DC INVERTER #2 1 I isconnect ! ! - 3 1 4�3P 4�3P )4�3P�4�3P i MPPT7 = ! T PLY WITH 2013 CALIFORNIA 'TRICAL CODE- ARTICLE 890.100 8(D) and 705.12(0)(8) REQUIREMENTS LNlityrinterconnected Electric Power iction Systems COMPLY WITH CALIFORNIA ELECTRICAL CODE- ARTICLE 690 REQUIREMENTS FOR SOLAR PHOTOVOLTAIC SYSTEMS COMPLY WITH 2013 CALIFOR04 ELECTRICAL CODE- ARTICLE 705 REQUIREMENTS FOR Interconnected Electric Power Production Systems PROPERTY OF Elite Solar ALL DESIGN PARAMETERS MUST BE CONFIRMED AND ADJUSTED TO MEET SITE SPECIFIC CONDITIONS OF USE. INSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT SELECTION AND INSTALLATION OF ALL EQUIPMENT AND MATERIALS TO MEET ANY POWER PRODUCTION COMMITMENTS AND ALL LOCAUNATIONAL CODE AND SAFETY REQUIREMENTS. Pw T . w � Elite Solar 15 PEPSI WAY DURHAM, CA 95938 (530) 345-9910 WWW. ELITESOLARCA.COM CSLB # 930561 C46 PROJECT INFORMATION NAME: 6 STRINGS OF ADDRESS: 15A CITY: CHICO, CA 95926 PHONE: 1.00 I I I- = G PROJECT#: Bare CU N/A 18 MODULES EACH. 618.8 150 0.51% DRAWN BY: CK SHEET TITLE ELECTRICAL DIAGRAM I 11.35 14.19 15 I 1.00 14.19 #10 AWG PV WIRE I #10 AWG Bare CU Solid MPPT2 / � 655.2 150 I APPROVED BY: DR I I 1 I 36 45.00 45 t 1.00 45 #8 AWG THWN-2 50 #10 AWG THWN-2 t 1" EMT/PVC 480.0 100 L-------------� SHEET NUMBER I ! t I o (or eq.) L---------� I PV -04 2 (TYP OF 4) I 1 C INVERTER#3 I Lt r---------- jinverter T1 = 3 ILLJ6 Lu ❑4 LOAD CENTER "ACCA" TO LOAD CENTER 144 180.00 200 0.82 1.00 180 #3/0 AWG (o eq.) STRINGS OF17 #6 AWG (ore 4.) - 2" EMT/PVC 480.0 150 0.60% Scale Confirm Plot MODULES EACH. "ACCB" T2 I , Elite17• ©Copyright 2014, ElSolar yr I r--------- -------- -- — — — — 0! PROPERTY OF Elite Solar ALL DESIGN PARAMETERS MUST BE CONFIRMED AND ADJUSTED TO MEET SITE SPECIFIC CONDITIONS OF USE. INSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT SELECTION AND INSTALLATION OF ALL EQUIPMENT AND MATERIALS TO MEET ANY POWER PRODUCTION COMMITMENTS AND ALL LOCAUNATIONAL CODE AND SAFETY REQUIREMENTS. Pw T . w � Elite Solar 15 PEPSI WAY DURHAM, CA 95938 (530) 345-9910 WWW. ELITESOLARCA.COM CSLB # 930561 C46 PROJECT INFORMATION NAME: PINE CREEK RANCH ADDRESS: 7020 CANA HWY CITY: CHICO, CA 95926 PHONE: 1.00 AHJ: BUTTE COUNTY APN#: D47L 0201 o14u 000 PROJECT#: Bare CU 1 Inverter DC INVERTER #4 I'€iMIT /l,,, fscod BUTTECOUNTY DEVELOPMENT SERVICES T1 3 �����®� AHJ SIGNATURE AND DATE 6 STRINGS OF CODE CDMPLIANP17 MODULES EACH. I/T2 I DATE � �4 BY i i CONDUCTOR, CONDUIT, AND VOLTAGE DROP SCHEDULE DERATES CONDUCTOR I CURRENT CARRYING CONDUCTOR EGC/GEC CONDUIT CONTINUOUS CONTINUOUS OCP REQUIRED CONDUCTORS AMPACITY (A) ONE WAY TAr_ riDri IIT CURRENT (A) CURRENT x 1.25 (A) S17'F T(amb) RACEWAY AMPACITY (A) SIZE (min) TYPE (PER NEC 310.16) SIZE (min.) TYPE SIZE TYPE VOLTAGE (V) DISTANCE (FT) REVISION SCHEDULE No. Dale I Description 1 03/16/15 Submittal) VOLTAGE DROP (% AT 75°C) F 2111.35 PV SOURCE CKT 14.19 15 0.87 1.00 14.19 ' PV WIRE 30 #10 AWG Bare CU N/A In free air 618.8 150 0.51% DRAWN BY: CK SHEET TITLE ELECTRICAL DIAGRAM PV SOURCE CKT (TYP OF 24) 11.35 14.19 15 0.87 1.00 14.19 #10 AWG PV WIRE 30 #10 AWG Bare CU Solid N/A In free air 655.2 150 0.48% APPROVED BY: DR DATE: 03/16/15 F 2111.35 PV SOURCE CKT 14.19 15 0.87 1.00 14.19 #10 AWG PV WIRE 30 #10 AWG Bare CU N/A In free air 618.8 150 0.51% SHEET TITLE ELECTRICAL DIAGRAM (TYP OF 24) Solid ❑3 INVERTER TO SOLAR LOAD CENTER 36 45.00 45 0.82 1.00 45 #8 AWG THWN-2 50 #10 AWG THWN-2 t 1" EMT/PVC 480.0 100 1.01% SHEET NUMBER (or eq.) (or eq.) PV -04 (TYP OF 4) , 1 inch ❑4 LOAD CENTER "ACCA" TO LOAD CENTER 144 180.00 200 0.82 1.00 180 #3/0 AWG (o eq.) 200 #6 AWG (ore 4.) - 2" EMT/PVC 480.0 150 0.60% Scale Confirm Plot "ACCB" , Elite17• ©Copyright 2014, ElSolar yr TAG DESCRIPTION 11,35 COMPONENT I COMMENTS SEE SHEET PV -04 O1 STRING OF PV MODULES IN SERIES 2 CANADIAN SOLAR CS6X-310P #10 AWG See Electrical Diagram for number of PV Modules per String I O INVERTERS - 5 THRU 8 I 18 MODULES EACH. ABB TRIO-27.6-TL-OUTD-S2F-400 #6 I MPPT2 O SOLAR LOAD CENTER "ACCB" 400A, 480V, 3Ph, 3W, 400A MAIN BREAKER O4 AC DISCONNECT 400A,480V, 3P, WITH 400A FUSES 55��I473P 4I3P )4�3P 4% ��P CONDUCTOR, CONDUIT, AND VOLTAGE DROP SCHEDULE O (N) MAIN ELECTRICAL SERVICE PANEL PV SOURCE CKT 400A, 480V, 3Ph, 3W, 400A MAIN BREAKER 14.19 Panel Upgrade CONDUCTOR CURRENT CARRYING 1 2 Inverter DC INVERTER #5 PV WIRE 1 I isconnect LINE SIDE TAP PER NEC 705.12(A). A THIRD In free air Fver,MeINVERTER MPP PARTY RECERTIFICATION OF THE MAIN T(amb) I SWITCH GEAR IS REQUIRED IF THERE ARE SIZE (min) 3 STRINGS OF 15A z ANY MODIFICATIONS TO THAT GEAR STRINGS OF 20 MODULES EACH. CONTINUOUS CONTINUOUS OCP MPPT2 3 (N) SOLAR LOAD CENTER "ACCB" CURRENT (A) f SIZE 400A, 480V, 3e, NEMA 3R 36 ( r—_ -------- -----=---C-- —__-- --- I 0.82 -------------- I' PV SOURCE CKT 11,35 14.19 I SEE SHEET PV -04 14.19 1 2 30 #10 AWG f I In free air 728.0 I 18 MODULES EACH. I #6 I MPPT2 I 55��I473P 4I3P )4�3P 4% ��P CONDUCTOR, CONDUIT, AND VOLTAGE DROP SCHEDULE F 21 PV SOURCE CKT 11.35 14.19 DERATES CONDUCTOR CURRENT CARRYING CONDUCTOR -3 PV WIRE 30 #10 AWG Bare CU N/A In free air Fver,MeINVERTER CONDUCTORS AMPACITY (A) T(amb) I SIZE (min) TYPE (PER NEC SIZE (min.) STRINGS OF CONTINUOUS CONTINUOUS OCP TAG CIRCUIT CURRENT (A) CURRENT x 1.25 (A) SIZE INVERTER TO SOLAR LOAD CENTER 36 AMPACITY (A) 20 MODULES EACH. 0.82 310.16) 45 #8 AWG fareq.) #10 AWG �orV 9•) 1" EMT/PVC 480.0 100 1.01% (TYP OF 2) ^V I I I I I I rq INVERTER TO SOLAR LOAD CENTER 36 45.00 45 0.82 1.00 45 I I 50 #10 AWG THWN 2 1" EMT/PVC 480.0 150 1.52% (TYP OF 2)F5 L. --------------J (or eq.) II (or eq.) I I I 2 2 SOLAR LOAD CENTER(2) 288 L ---------J I I I I 360 #3/0 THWN-2 400 INVERTER#7 THWN-2 -� - - - - - -III I I 10 F TO AC DISCONNECT I---•- AWG (or eq.) (or eq.) _6 DISCONNECT STRINGS OF Fisconnect 1.00 I 487.80 (2) #250 THWN-2 510 #3 AWG THWN-2 18 MODULES EACH. EMT/PVC 480.0 10 0.05% ❑AC 6 TO POI I KCMIL I (or eq.) (or eq.) I 0 I I Ij---------- ----- _ - --------- ---� { L-------------- I o 2 2 I Cr (N) MAIN SERVICE PANEL 400A, 480V, 3e IN (E) BRANCH FEEDERS & LOADS TO REMAIN 400A/3P MCB r-----------. I I i� (E) GND y I I 4 I j 5 6 j I AC, I Disconnect --------------- --------- r-- ----I r , INVERTER#8 PV SOURCE CKT 11,35 14.19 t SEE SHEET PV -04 14.19 *InverterC T16 PV WIRE 30 #10 AWG STRINGS OF I In free air 728.0 I 18 MODULES EACH. I (TYP OF 12) I MPPT2 Solid CONDUCTOR, CONDUIT, AND VOLTAGE DROP SCHEDULE F 21 PV SOURCE CKT 11.35 14.19 DERATES CONDUCTOR CURRENT CARRYING CONDUCTOR EGC/GEC PV WIRE 30 #10 AWG Bare CU N/A In free air REQUIRED CONDUCTORS AMPACITY (A) T(amb) RACEWAY SIZE (min) TYPE (PER NEC SIZE (min.) TYPE CONTINUOUS CONTINUOUS OCP TAG CIRCUIT CURRENT (A) CURRENT x 1.25 (A) SIZE INVERTER TO SOLAR LOAD CENTER 36 AMPACITY (A) 45 0.82 310.16) 45 #8 AWG PERMIT # BUTTE COUNTY DEVELOPMENT SERVICES REVEWED FOR C®DE MPLIANC E /DATE jBY C7� CONDUIT SIZE TYPE ONE WAY VOLTAGE DROP VOLTAGE M DISTANCE (FT) (% AT 75°C) PROPERTY OF Elite Solar ALL DESIGN PARAMETERS MUST BE CONFIRMED AND ADJUSTED TO MEET SITE SPECIFIC CONDITIONS OF USE. INSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT SELECTION AND INSTALLATION OF ALL EQUIPMENT AND MATERIALS TO MEET ANY POWER PRODUCTION COMMITMENTS AND ALL LOCAUNATIONAL CODE AND SAFETY REQUIREMENTS. ~dd « M A •4P ++,• 4b 4V -4 Elite Solar 15 PEPSI WAY DURHAM, CA 95938 (530) 345-9910 WWW. ELITESOLARCA.COM CSLB # 930561 C46 PROJECT INFORMATION NAME: PV SOURCE CKT 11,35 14.19 15 0.87 1.00 14.19 #10 AWG PV WIRE 30 #10 AWG Bare CU N/A In free air 728.0 150 0.44% (TYP OF 12) Solid F 21 PV SOURCE CKT 11.35 14.19 15 0.87 1.00 14.19 #10 AWG PV WIRE 30 #10 AWG Bare CU N/A In free air 655.2 150 0.48% (TYP OF 12) Solid INVERTER TO SOLAR LOAD CENTER 36 45.00 45 0.82 1.00 45 #8 AWG fareq.) #10 AWG �orV 9•) 1" EMT/PVC 480.0 100 1.01% (TYP OF 2) 50 rq INVERTER TO SOLAR LOAD CENTER 36 45.00 45 0.82 1.00 45 #8 AWG THWN 2 50 #10 AWG THWN 2 1" EMT/PVC 480.0 150 1.52% (TYP OF 2)F5 (or eq.) (or eq.) 1 SOLAR LOAD CENTER(2) 288 360.00 400 0.82 1.00 360 #3/0 THWN-2 400 #3 AWG THWN-2 (2) 2 EMT/PVC 480.0 10 0.04% TO AC DISCONNECT AWG (or eq.) (or eq.) DISCONNECT 0.82 1.00 I 487.80 (2) #250 THWN-2 510 #3 AWG THWN-2 (2) 2-1/2" EMT/PVC 480.0 10 0.05% ❑AC 6 TO POI I KCMIL I (or eq.) (or eq.) PROPERTY OF Elite Solar ALL DESIGN PARAMETERS MUST BE CONFIRMED AND ADJUSTED TO MEET SITE SPECIFIC CONDITIONS OF USE. INSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT SELECTION AND INSTALLATION OF ALL EQUIPMENT AND MATERIALS TO MEET ANY POWER PRODUCTION COMMITMENTS AND ALL LOCAUNATIONAL CODE AND SAFETY REQUIREMENTS. ~dd « M A •4P ++,• 4b 4V -4 Elite Solar 15 PEPSI WAY DURHAM, CA 95938 (530) 345-9910 WWW. ELITESOLARCA.COM CSLB # 930561 C46 PROJECT INFORMATION NAME: PINE CREEK RANCH ADDRESS: 7020 CANA HWY CITY: CHICO, CA 95926 PHONE: AHJ: BUTTE COUNTY APN#. 047L 0201 014U 000 PROJECT#: AHJ SIGNATURE AND DATE I REVISION SCHEDULE 1No. I Date I Description 1 1 1 03/16/15 ISubmittall DRAWN BY: CK APPROVED BY: DR DATE: 03/16/15 SHEET TITLE ELECTRICAL DIAGRAM SHEET NUMBER PV -05 i 1 inch Scale to Confine 11"x17" Plot ©Copyright 2014, Elite Solar r DESIGN TEMERATURES Lowest Expected Temperature 25°F -4°C Average High Temperature 106°F 41°C PV MODULE ELECTRICAL SPECIFICATIONS PINE CREEK RANCH MANUFACTURER CANADIAN SOLAR MODEL CS6X-310P PMAX (NOMINAL OUTPUT POWER) 310 W VMP (VOLTAGE AT PMAX) 36.4 V IMP (CURRENT AT PMAX) 8.52 A VOC (OPEN CIRCUIT VOLTAGE) 44.9 V [SC (SHORT SIRCUIT CURRENT) 9.08 A VOC TEMPERATURE COEFFICIENT -0.34 %/°C INVERTER ELECTRICAL SPECIFICATIONS PINE CREEK RANCH MANUFACTURER ABB MODEL TRIO-27.6-TL-OUTD-S2F400 NOMINAL AC POWER 27.6 KW NOMINAL OUTPUT VOLTAGE 480 V NOMINAL OUTPUT CURRENT 36 A OCP SIZE 45 A MPPT_MIN AT FULL POWER 200 V MPPT MAX AT FULL POWER 950 1 V MAXIMUM DC VOLTAGE 1000 V DC SOURCE INFORMATION PINE CREEK RANCH 12 STRINGS OF 17 MODULES TO INVERTER 1: 204 MODULES 24 STRINGS OF 18 MODULES TO INVERTER 2: 432 MODULES 6 STRINGS OF 20 MODULES TO INVERTER 3: 120 MODULES TOTAL NUMBER OF PV MODULES: 756 MODULES APNS: 047L 0201 014U 000 NUMBER OF MODULES IN LARGEST STRING 20 1 MODULES MAX. STRING VOC (20 x VOC) 898.0 V MAXIMUM DC SYSTEM VOLTAGE: Max. String Voc x {1 + [(T_low - 25) x T_coeff j): 763.3 x {1 + [(-4 - 25) x -0.0034)) = 839.0 V PROPERTY OF Elite Solar ALL DESIGN PARAMETERS MUST BE CONFIRMED AND ADJUSTED TO MEET SITE SPECIFIC CONDITIONS OF USE. INSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT SELECTION AND INSTALLATION OF ALL EQUIPMENT AND MATERIALS TO MEET ANY POWER PRODUCTION COMMITMENTS AND ALL LOCAUNATIONAL CODE AND SAFETY REQUIREMENTS. s�i t � A �i N,� •tiN tee' EI Ito solar; 15 PEPSI WAY . DURHAM, CA 95938 (530) 345-9910 WWW.ELITESOLARCA.COM - CSLB # 930561 C46 PROJECT INFORMATION NAME: PINE CREEK RANCH ADDRESS: 7020 CANA HWY CITY: CHICO, CA 95926 PHONE: AHJ: BUTTE COUNTY APNS: 047L 0201 014U 000 PROJECTS: AHJ SIGNATURE AND DATE I REVISION SCHEDULE No. Date Description 1 03/16/15 Submittal) PERMIT # DRAWN BY: CK .. .. BUTTE r APPROVED BY: DR COUNTY DEVELOPMENT gt�v10; 5 DATE: 03/16/15 REVIEWEDFOR SHEET TITLE DATE CODE oMPLIAjt, CE ELECTRICAL CALCULATIONS SHEET NUMBER PV -06 1 inch , R Scale to Confirm 11x17" Plot ©Copyright 2014, Elite Solar INV #8 SOLAR LOAD CENTER #1 INV # INV #6 INV #5 1NV #3 PROPERTY OF Elite Solar ALL DESIGN PARAMETERS MUST BE CONFIRMED AND ADJUSTED TO MEET SITE SPECIFIC CONDITIONS OF USE. INSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT SELECTION AND INSTALLATION OF ALL. ' EQUIPMENT AND MATERIALS TO MEET ANY 4' POWER PRODUCTION COMMITMENTS AND ALL LOCALMATIONAL CODE AND SAFETY REQUIREMENTS. " _ •mss � � ��.S, K j Elft .solar s 400A MAIN SERVICE PANEL 15 PEPSI WAY / EXISTING UTILITY POLE DURHAM, CA 95938 SOLAR LOAD CENTER #2. (530) 345-9910 WWW.ELITESOLARCA.COM . :NCH M CSLB # 930561 C46 400A FUSED AC PROJECT INFORMATION DISCONNECT v- F t pCAMIr �t NAME: PINE CREEK RANCH ADDRESS: 7020 CANA HWY CITY: CHICO, CA 95926 PHONE: AHJ: BUTTE COUNTY APN#: 047L 0201014U 000 PROJECT#: BUTTE COUNTY DEVELO MEP NIRERVICES" 5 CODE VIE FOR E C MPLIANCE S_6 DATE � 13 AHJ SIGNATURE AND DATE REVISION SCHEDULE No. Date Description 1 03/16/15 Submittal 1 DRAWN BY: I CK APPROVED BY: I DR DATE: 03/16/15 SHEET TITLE EQUIPMENT LAYOUT SHEET NUMBER PV -07 1 inch , Scale to Confirm 11"x17" Plot ©Copyright 2014, Elite Solar Text: 3/8" Min. 4" Location: Inverter ID N.T.S. Text: 3/16" Min. :,WARNING. SOLAR PV LOAD CENTER7 2 DO NOT ADD LOADS- " l, 1 % , i-_ I . _'NOMINAL ACiVOLTAGE: 480 V. SOLAR LOAD CENTER N.T.S. Text: 3/16" Min. be NOT TERMINALS ON'BOTH THE t_INE AND 2" N.T.S. Text: 3/16" Min. N.T.S. _5" NUINAL' Al, OPERATING AC OC� UTPUT-CURRENT: 2 • 0 I N.T.S7 % PHOTOVOLTAIC'[ "OPERATING CUF 2 OPERATING VOI MAX.�SY,STEM VC SHORT-CIRCUIT C 5 i�r PHOfOVOLTAIC -1 �1:t 40 -'.0PERATINGtbi OPERATING VOI MAX.:SYSTEM VC 11 �.%SHORT-CIRCUITtC 5" L PHOTOVOLTAIC HOTOVO' f 'CUF k PAT OERING 7 iT - - _1 - , 2" -OPERATINGVOl MAX S Y S T A, , V z J�7SHORT'-.CIRCUIT C Location: Inverters' N.T.S. NAME: PINE CREEK RANCH ADDRESS: PROPERTY OF CITY: CHICO, CA 95926 PHONE: Elite Sillar AHJ:' BUTTE COUNTY APN*. ALL DESIGN PARAMETERS MUST BE CONFIRMED IPROJECT#: I , I AND ADJUSTED TO MEET SITE SPECIFIC CONDITIONS OF USE. INSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT SELECTION AND INSTALLATION OF ALL EQUIPMENT AND MATERIALS TO MEET ANY 2"• POWER PRODUCTION COMMITMENTS AND ALL •LOCAUNATIONAL 0 CODE AND SAFETY REQUIREMENTS: 5" System - AC Dsiconnect Elite Solar N. T.S. 15 PEPSIWAY DURHAM, CA 95938 (530) 345-9910 WWW.ELITESOLARCA.COM .--,'DUAL POWARNING!WER SOURCE CSLB#930561 C46 20• -wrtarg-, I • PROJECT INFORMATION NUINAL' Al, OPERATING AC OC� UTPUT-CURRENT: 2 • 0 I N.T.S7 % PHOTOVOLTAIC'[ "OPERATING CUF 2 OPERATING VOI MAX.�SY,STEM VC SHORT-CIRCUIT C 5 i�r PHOfOVOLTAIC -1 �1:t 40 -'.0PERATINGtbi OPERATING VOI MAX.:SYSTEM VC 11 �.%SHORT-CIRCUITtC 5" L PHOTOVOLTAIC HOTOVO' f 'CUF k PAT OERING 7 iT - - _1 - , 2" -OPERATINGVOl MAX S Y S T A, , V z J�7SHORT'-.CIRCUIT C Location: Inverters' N.T.S. NAME: PINE CREEK RANCH ADDRESS: 7020 CANA HWY CITY: CHICO, CA 95926 PHONE: AHJ:' BUTTE COUNTY APN*. 047L 0201 014u 000 IPROJECT#: I , I Z -;4 OD A rJSIGNATURE AND DATE m7 z _� 1I1<___ y • C) ,� 4®UTTE Aid 0-PMENT SERVICE! REVISION SCHEDULE RFVIE1i ? No. Date Description V ED FOR 1 03116/15 Submittal I 1A C CE DRAWN BY: CK Z APPROVED BY: DR < DATE: 103/16/15 SHEET TITLE SIGNAGE SHEET NUMBER PV -08 I inch Scale to Confirm 11"x17" Plot ©Copyright 2014, Elite Solar a._ } �. ,'S,