HomeMy WebLinkAboutB15-1982^07
tet~ _ � �, 31� ` '�. , ��• ,,��",y l 7f •�
`-- Meter Main/Invert
Location (inside)
^- A.
r
x •
J
r;. r�RAlar Array
F a- ounted on
i
. Site `Mau
1
t W Proiect otes:
�t Solar PV Installation
- ' DC Conductors Present. - -
Alp _ - ...-
Iu`? All Points of AC Disconnect to be labeled.
All Points of DC Disconnect to be labeled.
All Construction shall comply with the 2013 CBC,CRC &
CEC.
All markings to be compliant with Section R331,2 and
placed on interior and exterior Direct-current (DC)
conduit; enclosures,raceways, cable assemblies
Sub Panel/Inverter �, F -
Location
junction boxes,combiner boxes and disconnects.
r The materials used for marking to be compliant with
Section R331.2.1 & be reflective, weather resista_ nt and
suitable for the environment. Markin as re wired
` 9 G
Maintain 4' Clearance in Sections R331.2.2 through 11331:2.4 shall have all
letters capitalized with a minimum height of 3/8 inch
I. as per, 2013 CRC -`W (9.5 mm) white on red background.
Section R331.4 The marking shall contain the words "WARNING: PHOTO
VOLTAIC POWER SOURCE." as per Section R331.2.2.
•�
Marking shall be p j laced adjacent to the main service
`
disconnect ina location clearly Visible from the location
where the disconnect is operated per Section R331.2.3.
W ` �« x t t Marking shall be placed on interior and exterior DC
..� � - � ;• � � . '. .r � conduit; raceways, enclosures and cable assemblies
every 10 feet, within1 foot of turns or bends and
14. tions of
..� w
• ithin 1 foot above and below penetrations
roof/ceiling�} assemblies, walls or per Section
R331.2.4.
Arl,•
,�.rry PEI�JIATP# 5 — BUTTE
l 1���
�`' • ri �% 1 r BUTTE COUNTY DEVELOPMENT SERVICES
COUNT'
REVIEWED FOR NOV 23 2015
COMPLY NIA
ELECTR/ AIL CODEFARTICLE 690 CODE COM PLI CE
REQUIREMENTS FOR SOLAR DATE DEVELOPMENT
PHOTOVOLTAIC SYSTEMS : SERVTCES
• I
DRAWN BY CHECKED DATE SCALE SHEET NO.
Singh, Commercial Westhaven Inc
120 CA -99, Gridley, CA 95948 teFlor s 09/29/2015 NA 1
CA LIc 965111.
3
Rooflayout ,
System Detbils: Mountie Notes:. �+
11.11KW Solar PV System =Panels mounted on aluminum racking. _
3.4 Sunpower SPR-E20=327 Panels n Ii �' •+,~ -PV array mounts to roof structure-
1 SMA Sunnygoy 3800TL-US-240V Inverter: with 3/8" lags,.embedded 2 i/2" into
I SMA Sunny[3oy 6000TL-US�240V� Inverter' rafters
-PV panels are anchored at 48" 0. C.
Trusses/Rafters "are ,24" O.C. .
Weight of. PV modules and assembly
- I e foot
'. panels are:on� 'pe square
.
less than 51bs� r ar
fifferirentIts ane-of � 1
4.
_ the roof and Wil! Construction Notes:.
" p be set at. 13 a' panels aref All Construction shall comply with 2013
9�
be e; ,
-e P itch ' -t. own a: ' California Building Code (CBC), 2013
fifferent {' �= California Plumbing'Code (CPC), 2013
plan4 o California:Mochanical Code (CIVIC), 2013
he roof
and.wiil be Califorriia,Electrical Code ( CEC), 2013
California Energy'Code, The 2013
set at 4 ,,
Degree California Fire Code (CFC), And All
i� tch f applicable codes.
+PERMIT#
1 _ BUTTE COUNTY. EVELOPMENT SERVICES
,.REVIEWED FOR
.COD
y
ATC 2 g k
,L
-an
R
-• Rafters 24" O C - .
Mount all ors
x A
Maintain 4' _
Clearance
as..pgr 21013
CFlC Section
R331.4:
' • •i�'tat 'r. " ..• - �` .. ^ f' -�'•• `_ F''.QK.8.28in•s.:.-+. rY�r..,+ :
s, r ti
t M. TE s SCALE . SHEET NO.
Singh' Commercial
DRAWN BY CHEC
KED DA
1220 CA-99'G CA 95948 t �: Westhaven Inc esner 09/14/2015 NA 2
y, CA Lic 965111
� r•
0
13
System Details:
11.11KW Solar PV System
34 Sun power SPR -E20 -US -327 Panels
1 SMA SunnyBoy 6000TL-US-240V Inverters
1 SMA SunnyBoy 3800TL-US-240V Inverters
3 Strings 1 String of
Of . P
.COMPLY WITH CALIFORNIA � %Panels
7 Panels ELECTRICAL CODE- AR77CLF 250
REQUIREMENTS FOR GROUNDING ! 1
AND BONDING String of
6 Panels
14)
60007E (3j 38007E
Inverter D.C.
w _ K Inverter D.C.
A.C. -
COMPL Y MW 2013 CALIFORNIA i A.C.
Integrtated ELECTRICAL CODFARTICLE690.>0(E).
408.3610) and 705.12(0X6) REQUIREMENTS ! Integrtated
Disconnect FOR uiddy -Interconnected Elecbic Power h
Pkvducton systemsDisconnect
J'
4 T WExisting 4
Sub �.
30 Panel ---.
Shop S
9
TAG
DESCRIPTION
NOTES
1
Solar Array
36 Sunpower SPR -E20-327 Panels
2
Wire, Ground, Conduit
#10-(6)CU,#10-(4)CU, #6 Ground, 3/4" EMT
3
Inverter with Intergrated DC Disconnect
SMA SunnyBoy 6000% 3800TL-US-240V Inverter
4
Wire , Ground, Conduit
#10-(3)CU, #10-(3)CU, #6 Ground, 3/4" EMT
5
Solar Circuit Breaker
30A, 20A 2 Pole Square D
6
Existing Sub Panel
125A Eaton fed by an Existing 100A 2 Pole
7
Wire, Ground., Conduit
Existing #3 THHN
8
Circuit Breaker
100A 2 -Pole Square D for Existing Sub Panel
9
ISolar Load Center
150A LugFed NEMA3 Square D
10
JPV Supervisor Circuit Breaker
15A Single Pole Square D
11
Wire, Ground, Conduit
#3430, #6 Ground, 3/4" EMT
12
Fused AC Disconnect
Cutler Hammer DG224 NRB Fused AC Disconnect 100A Fuses
10
Wire, Ground, Conduit
#3430, #6 Ground, 3/4" EMT
11
Circuit Breaker Solar toad Center
100A Single Pole Cutler Hammer
12
Main Service Panel
200A Cutler Hammer with a 17,5A Main Breaker
COMPLY WITH CALIFORNIA I
ELECTRICAL CODE- ARTICLE 690
REQUIREMENTS FOR SOLAR
PHOTOVOLTAIC SYSTEMS
Solar
Load
�—' Center
i PERMIT # 1?7 L15— l !� 91�>Z
BUTTE COUNTY DEVELOPMENT SERVICES
- - REVIEWED FOR`+
Label, circuitbreaker(s), CODE COMPLI VE
disconnect(s), fuse(s),switch(es) and DATA I'Z� IT��' B
their accessories, to identify their k
location and or equipment Electric Notes:
-PV equipment shall be
installed in accordance with
2011 NEC Article 690 and
any other applicable
articles.
! 1�,, x '-- ----� q .1" - Per Section 690.53 a
Q _ 14�ijj permanent label for the DC
�--'" \� . _ Fused AC / �-,
] s Provide readily accessible capability to } ;p;� power source shall be
circuit breaker<s),disconnect(s), Disconnect ) OOq .:� installed at the PV DC
fuse(s),switch(es) and their accessories L
as required and defined iwCaliforrii, disconnect.
Electrical Code
DRAWN BY CHECKED� DATE SCALE SHEET NO.
Singh Commercial
99 Gridley, CA 95948 westhayen Inc
1220 CA
" � ,y, CA Lic 965111 esner Flores 009/14!2015 NA 3
HIGH PERFORMANCE & EXCELLENT DURABILITY
E20 - 327 PANEL
HIGH EFFICIENCY°
Generate more energy per square foot
E -Series residential panels convert more sunlight to electricity producing
36% more power per panel,' and 60% more energy per square foot
over 25 years. 3,4
HIGH ENERGY PRODUCTION
Produce more energy per rated watt
High year one performance delivers 7-9% more energy per. rated Watt.3
This advantage increases over time, producing 20% more energy over
the first 25 years to meet your needs.'
20%
More Energy
Per Rated Watt
15 20
Years
............. I ...........
......__.
! Maintains High
' Power at High Temps
l-=J~No light -Induced
II Degradation
Average Watts
35% more,
year 25
25
F LOPMENT SERVICES
ED FOR
App ,
aY
www.sunpower.com
SunPc
EDO C6
20%
More Energy
Per Rated Watt
15 20
Years
............. I ...........
......__.
! Maintains High
' Power at High Temps
l-=J~No light -Induced
II Degradation
Average Watts
35% more,
year 25
25
F LOPMENT SERVICES
ED FOR
App ,
aY
www.sunpower.com
? '
ELECTRIC�ALDA71A��
Quality tests
420-327.�j E19-320
Nominal Power 12 (Pnom)'327
W 320 W � `
Power Tolerance .
+5/-0% +5/-0°/a "
,Avg. Panel Efficiency"
20:4%
Rated Voltage (Vmpp)
54.7 V 54.7.V
Rated Current (Impp)
5:98 A 5.86 A"
Open -Circuit Voltage (Voc)
64.9 V 64.8 V
Short -Circuit Current (Isc) ;
' 6:46 A-' 6.24 A
Max., System Voltage
600 V UL & 1000 V IEC :` ..
Maximum'Series Fuse
15 A
Power Temp Coef.'
-- -0.38%/-OC `
Voltage Temp Coef".
-176:6 mV /,PC,
Current Temp Coef.
- ' 3.5 mA / 'C .,
REFERENCES:
1 All comparisons are SPR -E20327 vs: a representative conventional' panel: 250W,
approx. 1.6 m2, 15:3% efficiency. "
2 PVEvolution Labs "SunPower Shading Study," Feb 2013.
3 Typically 7-9% more energy, per watt, BEW/DNV Engineering "SunPower Yield
Report," Jan -2013.
4 SunPower 0.25%/yr degradation vs. 1.0%/yr conv. panel. Campeau, Z._, et al.+
° OP�TMING C;ON ID T�;I®N,AND, MECFiA�NICAL�DAT�A '
Temperature
Quality tests
Ma z load
Wind: 50 psf, 2400 Pa, 245 kg/M2-front & back.
Snow: 1 12,psf, 5400 Pa; 550 kg/m2"front
Impact resistance
1 inch (25mm) diameter hail at 52 mph "(23•m/s). '
Appearance -
Class A .
Solar Cells"
96 Monocrystalline Moxeon Gen II
Tempered Glass""'
High transmission: tempered Anti -Reflective
Junction Box.
IP-65 Rated
Connectors `,
MCA Compatible Connectors
Frame;
Class ;l=black anodized (highestAAMA rbting)
Weight
'4l lbs (18.6 kg)
Standard tests
ETES-SA`ND CERTIFICATIONS•
UL1703 (Type 2 Fire.Rating), IEC 61215, IEC 61730
Quality tests
ISO 9001:2008, ISO 14001:2004
EHS Compliance
RoHS, OHSAS 1.8001:2007; lead free'-
ree .Ammonia
Ammoniatest
IEC 62716 j
Salt Spray test
1EC 61701 (passed maximum°severity)
PID test
Potential-lnduced,D " raclation free: 1000V10 .
Available listings-
.:UL, CEC,'CSkTUV,`JET, KEMCO, MCS; FSEC
"SunPower M u e Degradation Rate," SunPower white paper, Feb 2013; Jordan,Dirk
"SunPower Test Report," NREL, Oct 2012.
5 "SunPower Module AO -Yeo rUsefulLife" SunPower white paper, Feb.2013. Useful ,
life is 99 out of I00,panels operating at more than 70% of rated power.
6 Second highest, after SunPower XSeries, of over 3,200 silicon solar;paneli,
Photon Module Survey, Feb 2014.9 . "
1046 mm
7`8% more energy than the average of the top 10 pohel companies tested in2012
[41:2 in]
(151 panels, 102 companies)', Photon International, Feb 2013
-
8 Compared with the top 15 manufacturers. SunPower Warranty Review; Feb
,1 2013.
9 Some exclusions apply. See warranty for details.
10 5 of to 8 panel manufacturers from 2013 re rt were tested, 3 additional
P P. po"
46 mm �{
'
.— 1559 mm
siliconsolar panels for the 2014. Ferrara, C., et al. "Fraunhofer PV Durability. .,,
[1.8 in]' [61.4in]
Initiative for Solar Modules: Part 2". Photovoltaics International 77-85 2014:
11 Compared with. the non -stress -tested control • panel.,,Adds 25+ Durability test
pEfZ1VIfT.# �(5 JAI- '
report, Feb 2013.from 2013 report.were tested, 3 additional'silicon solar: panels
BUTTE.000NTY DEVELOPMENT SERVICES •:
for the 2014.' Ferrara, C.; et al. "Fraunhofer PV Durability' Initiative for -Solar
Modules: Part 2". Photovoltaics International, 77-85. 2014.
'%�I
E E ®F®
2, Standard Test Conditions (1000 W/m? irradiance, AM 1.5, 25°.C)
N®a
�f Y
.o n
a'3 Based or average of measured power values duririgproduction
1 V 7 9'
DATE l 2 3
E1Y" -
See http://wyw.sunpower.com/focts for more reference information. ; e
For more details, see extended dotasheet: www.sunpower.com/datasheets. Read safety and installation instructions before using this product. .sunpower.com." .
®December 2014 SunPower Corporation. All rights reserved. SUNPOWER, the SUNPOWER logo, MAXEON,.MORE ENERGY. FOR UFE., and SIGNATURE are m
tradearks or registered
trcdemorke of SunPower Corporation. Specifications included in this datosheet are subiect to change without notice.
Document # 504860 Rev D ATR_US
SUNNY BOY 300OTL-US / 380OTL-US /
400OTL-US / 500OTL-US / 600OTL-US
SMA
Certified
Innovative
Powerful
• UL 1741 and 16998 compliant • Secure Power Supply provides • 97.2% maximum efficiency
• Integrated AFCI meets the require- daytime power during grid outages • Wide input voltage range
ments of NEC 2011 690.11 • Shade management with OptiTrac
Global Peak MPP tracking
i.
SUNNY BOY 3000TL-US / 380OTL-US /
4000TL-US / 5000TL-US'./ 6000TL-US
Setting new heights in residential inverter performance
ENGINEERED
W r'FPKAANIV
MOO L IVI D LL U XZ
IN THE USA=
Flexible
• Two MPP trackers provide
numerous design options
• Extended operating
temperature range
/The Sunny Boy 3000TL-US/3800TL-US/4000TL-US/5000TL-US/6000TL-US represents the net stepinperorrmmance for
UL certified inverters. Its transformerless design means high efficiency and reduced weight. Maximum power production
is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTracTm Global Peak
mitigate the effect of shade and allow for installation at challenginggvi es
ft E, PIS
daytime power in the event of a grid outage. High performance, flexible desig n ny Boy
TI -IIS ceriac ti�a firct rknirP mmnnn cnlnr nrnfaccinnnlc DEIR
8 ��� (3
CODEC
A NEW GENERATION OF INNOVATION C
Transformerless design
produced in all types of-climates, and - for
Leading monitoring +
longer periods of time-`than 'with most
and control solutions
The Sunny Boy K00TL-US / 380OTL-US
traditional string inverters
/ 4000TL US / 5000R-US` /=6000TL US-'
r. '
The,new Tl US, residential line features more
are trans(ormerless, inverters; which means
Secure Power Supply
than high performance and a large• graphic {
owners and install,ers benefit from high
r :.
display. ,The monitoring and control options
efficiency. and lower weight. A wide input
One of many umquefeaiures of the TL-US
'provide users with an outst6nding degree of
voltage range also means the inverters will
residential series" is its innovative Secure
flexibility. Multiple communication options
produce high amounts of power under a
Power, Supply.. With most grid-tied inverters,
allow for a highly controllable inverter
number of conditions.when
the grid goes down, so does the solar-
and one that can be monitored oh' Sunny '
powered home: SM,A's solution provides
_Portal from anywhere on the planet via an
Additionally, transformerless inverters have
daytime energy to a.dedicated power outlet
Internet'connection. Whether communicating ,
been shown to be among the safest string
during prolonged' grid outages, providing.
through RS485, or SMA's new plug-and-play
inverters on the marxet. An industry first, the
homeowners with access to power as long
WebConnect, installers can find an optimal
TL-US series has bee.-) tested to UL 1741 and
'as the sun shines.-l'-
solution to their monitoring needs.
UL 16998 and is in compliance with the arc
fault requirements of NEC 201 1.
Simple install ction, r
Increased energy production
As a transformerless inverterthe TL US
._ r
residential series -is lighter in weight than
OptiTrac'm Global Peak, SMA's shade-
its transformer-based counterparts, making
`
tolerant MPP traclang algorithm, quickly
it easier to lift and transport. A new wall
-
adjusts to changes ir solar irradiation; which
mounting plate features anti-theft security
mitigates the effects of shade and results in
and makes hanging the inverter quick and'
higher total power output. And, with two MPP
easy,. A simplified DC wiring concept allows
trackers, the TL-US veries can ably handle.
the DC disconnect to be Used as a wire
-
complex roofs with multiple orientations or
raceway, saving labor and materials.
string lengths.
The 3800TL-U.S model allows installers 'to
®'.
BUTTE COUNTY
An extended operating temperature range
maximize system size and energy production'
'-BUIL.DING DIVISION.
of -40 ° F to +140 *F ensures power is
for customers with l 00 A service panels.
pY''�PP ®�
YOVED
Shade management ACg f-
Max, o�tput,curre
Po'�fac�fo j os
(D– —r
phases / I
Y
- Harmomcs
Efficiency
Marx.,eiRcxcienry'
GEC-- efficiency'
Brotectiondevice
Easier
DCdiscon ectiTon
DC� revers�la 1
General rintn -
Tedniical data confined on back"
-
- - ---i
---------------------------
Efficiency curve SUNNY BOY 5000TL-US } --
---------------------------
_._._ _- __ I I ,
Sunny Boy 6000TL-US
<-
98
208 V AC 240 V AC
208 V AC 240 V AC
208 V AC ? . 240 V AC
Input (DC)
Mox._ usoble DC power (q cos rp - t)W
_.__... ......_.
4206
_ .. . ..........
_
5300 W
__... 6300 W
Max. DC voltage _- _
_ 600 V
600V e
600 V
Rated MPPT voltage range
-
96
--..
,..
210 - 480 V
...,..
..
............
....
...........
_ Min.. DC voltage / start voltage ;
125 V / 159V....
94
' '
Max. input current / per MPP tracker
24 A/ 15 A
30A / 15 A
30A/ 15 A
Number of_MPP trackers./ strings per MPP_hacker _.. ,
2 / 2
`.
,_•
AC nominal power _-4000
W
Eli
I �+
92
4000 VA,
4550 VA 5000 VA
5200 VA 6000 VA
Nominal AC voltage /adjustable _.
208 V / • ; 240. V / •
208 V / • 240 V / •
208 V / • 240 V / •
AC voltage range
i
I y
- 229 V 211 - 264 V
AC_grid frequency; range_
60 Hz / 59.3 - 60.5 Hz
60 Hz /-59.3 - 60.5 Hz
60 Hz / 59.3 - 60.5 Hz
a^p 97
20A
22A
yyq
EE
w
90
Output phases / line connections
1.i 2
/2 ,.
; . 1./2
1 / 2
Harmonics __._ _ _..- _ . . ___..
<49
__.-
r <4% __ : _
--------_ <4%
Efficienry
Wi
96.86/. , 0.2%
96.8% 97.1 %
96.8%* _ 97.1%*
(
88
96% ;- 96.5%
96%* 96.5%*
Eto (VM- 175 VI
i 95'
DC disconnection device
li
DC reverse -polarity protection•
�•.•
Eta IV„ - 400 V)
g 175
480
Ground fault monitoring /.Grid monitoring _ , __ _.. _
_. _
_._. •,/_•
86
AC short circuit protection
-
Eta NN - 480 VI
Vw, IVI
AlLpole sensitive residual current monitoring unit
Arc fault circuit interrupter(AFCIJ compliant to UL 1699B
•
Protection class / overvoltage category
0.0
0.2 0.4 0.6 0.8 1.0 1
jOutput
General data
power / Rated power 4 i
Accessories
Speedwire/Webconnect RS485 interface
interface "_85CB-US-10
SWDMIIS-10
1 Fon kit
FANKR02.10
• Standard feature 0 Optional feature - Not available
Data at nominal conditions
Technical data
Sunny Boy 4000TL-US
.... -.
Sunny Boy 5000TL-US
-,
_._._ _- __ I I ,
Sunny Boy 6000TL-US
<-
208 V AC 240 V AC
208 V AC 240 V AC
208 V AC ? . 240 V AC
Input (DC)
Mox._ usoble DC power (q cos rp - t)W
_.__... ......_.
4206
_ .. . ..........
_
5300 W
__... 6300 W
Max. DC voltage _- _
_ 600 V
600V e
600 V
Rated MPPT voltage range
-
175 - 480 V
_. _.
175 - 480 V
210 - 480 V
MPPT operating voltoge range __ __, ,
125 V - 500V
; 125 V - 500V
125 V - 500V
_ Min.. DC voltage / start voltage ;
125 V / 159V....
j ' 125 V/_ 150 V
__ 125 V / 1.50 V
Max. input current / per MPP tracker
24 A/ 15 A
30A / 15 A
30A/ 15 A
Number of_MPP trackers./ strings per MPP_hacker _.. ,
2 / 2
`.
Output (AC)
AC nominal power _-4000
W
; 4550 W 5000 W
5200 W 6000 W
Max. AC apparent power
4000 VA,
4550 VA 5000 VA
5200 VA 6000 VA
Nominal AC voltage /adjustable _.
208 V / • ; 240. V / •
208 V / • 240 V / •
208 V / • 240 V / •
AC voltage range
183 - 229 V 211 - 264 V
; 183 - 229 V, 211 - 26-4,V 183
- 229 V 211 - 264 V
AC_grid frequency; range_
60 Hz / 59.3 - 60.5 Hz
60 Hz /-59.3 - 60.5 Hz
60 Hz / 59.3 - 60.5 Hz
Max. output current
20A
22A
25A
Power factor (cos tp)
Output phases / line connections
1.i 2
/2 ,.
; . 1./2
1 / 2
Harmonics __._ _ _..- _ . . ___..
<49
__.-
r <4% __ : _
--------_ <4%
Efficienry
Max, efficiency_
96.86/. , 0.2%
96.8% 97.1 %
96.8%* _ 97.1%*
CEC efficiency -
_96% ,- 96.5%
96% ;- 96.5%
96%* 96.5%*
Protection devices
DC disconnection device
DC reverse -polarity protection•
-
Ground fault monitoring /.Grid monitoring _ , __ _.. _
_. _
_._. •,/_•
AC short circuit protection
-
AlLpole sensitive residual current monitoring unit
Arc fault circuit interrupter(AFCIJ compliant to UL 1699B
•
Protection class / overvoltage category
_
_
I /,IV
General data
Dimensions (W,/ H / D) in mm (in) _. ;
490 / 519 / 185 (19.3 / 20.5 / 7.3) _-
DC Disconnect dimensions (W/_H/,D) in mm (in)
--
187/ 297/490 17.4 / 1 U/ 7.5)
Packing dimensions (W/ H / D) in_mm (in) _
_ _
617 / 597/ 266 (24.3 /23.5/ / 10.5)
DC Disconnect packing dimensions (W / H / D) in mm (in) , ,
370 / 240 / 280 (1.4.6 / 9.4 / 1 1.0)
_
_
Weight / DC Disconnectweight
(8 Ib)
Packing weight / DC Disconnect packing weight
27 kg (601b) 3.5 kg (8.1b)
Operating temperature range __ ; ,
-40 C ... +60 °C (-40 F ... +140 °F) _
Noise emission [typical).. _ _ .
_ < 25.dB(A,). _._
< 29 dB(A) _. ; ' --
_.... < 29.dB(A)
Internal consumption at m ght
< 1 W
< I Vy
< 1 W
Topology _-
Tronsformerless
Transformedess
Transformerless
e
Cooling concept
Convection
Convection
Active Cooling
Electronics protection rating,
_.
NEMA 3R
_
NEMA 3R - _
NEMA 3R
_ _ ..
Features
Secure Power Supply
. , L_.
•
Display: graphic _...
t
• ; ._
-
Interfaces: RS485 / Speedwire/Webconnect
O/O
0/0
0/0"
Warranty: 10 / 15 / 26 years _
0/0/0
•/0/0
•/0/
Certificates and permits (more available on request)
UL 1741, UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1
* Preliminary data as ofFebruary2014. NOTE: US inverters ship with gray lids PEf2MIT # ` J - L S..'_G.rz
Type_ designation
SB 4000TL-US-22
_BUTTE CiOWMfDEVZLOPMENT.SERVICES6000TL-US•22
REVIEWED FOR
Toll Free +1 888 4 SMA USA
www.SMA-America.com
COfViPL
C9-z?--3
erica, LLC
DATF
I S- _ ®Y
..®,UNI RAC
Technical .1 I _ _ ��
A HILTI GROUP COMPANY "
4 SOLARMOUNT,Tech`Incal Datasheet -
Pub 130817
o ,
' SOLARMOUNT Module Connection Hardware'. ••..... ............................................... 1
Bottom Up Module Clip ...... .......: ....... ............... ..........P.:.....................................1
Mid Clamp, .... :....:..........:.:. '.: ...::::.. ::......`...........................
End Clamp...:.:........ ............:.;
................ 2
` SOLARMOUNT Beam Connection Hardware ...........:. :..:3
L -Foot` 3
SOLARMOUNT Beams......... �., y..
.. .. Y. �, ` .. �.�' - -. • yin. 3.
`SOLARMOUNT (Nodule Connection" Hardware
SOLARMOUNT Bottom Up Module Clip, r
Part No: 302000C
Bottom Up Clip material One of the following extruded aluminum,
_ r Bottom ut' (h�dd yn��s �e ' alloys: 60057T5, 6105-T5,, 6061-T6" -
, F
'a.•
Up Clip.: eo Ultimate tensile: 38ksi; Yield: 35 Ksi.y -
Finish: Clear Anodized.. G
. Bottom Up,Clip-weight: --0.031 lbs (14g)
Beam ""k Bolt 'r� Allowable and design loads'are valid when components are
y ,y assembled with SOLARMOUNTseries beams according to
�autliorized.UNIRAC documents
Assemble with one'/<" -20 ASTM F593 bolt, one 1/4'-20 ASTM F594
serrated'flange"nut, and one'/<:,flatwasher,
Use anti -seize and tighten to 10,ft-lbs of torque
`Y Resistance factors.and safety:facti-qrs are determined according to
' .part 1 section 9 of the 2005 Aluminum Design Manual' and third-.
party test -results from an IAS accredited]aboratory
• Module edge must be.fully, supported.by the beam '
* • NOTE ON WASHER: install washer -on bolt head side -of assembly.
< - DO NOT; install washer'undk'serrated flange nut
Applied Load
Average
- "Allowable Safety
'"Design
_ Resistance.
Direction-
Ultimate
Load Factor,
�_ : Load
'. Factor,
lbs (N)
Ibs'(N) F3
-' Ibs (N)
m
Tension, Y+.` ,'
.1566 (6967) ,
686 (3052) 2.281038
(4615);
0.662
Transverse, X±
1 1128 (5019) ,
.329-(1463) 343
497 (2213)
-.':.: 0.441
Sliding, Z± ,
66:(292) • •
27.(119) ' .'2.44•
-4 1 '(181)
0:619
$0 LARMOU NT Mid Clamp
'Part No. 302101 C, 302101 D; 302103C, 302104D,
302105D, 302106'D,
7
i U'lm%'Jl
sms
A HILT? GROUP COMPANY
• =Mid clamp mate . rial: One of the following extruded aluminum
y
'allb s* 6005-T5- 16165J5, 6'061-T6
T Ultimate, tensile:. 38ksi, Yield: 35 ksi
Finish: Clear or Dark Anodized
9)
Mid clamp weight: 0.050 lbs (23'
Allowable. and design l6ads.are,valid when components -are
assembled according t0.authorized UNIRAC documents'
Values represent the allowable -and design I . oad I capacity of a single
:t Mid clamp assembly when used with a SOLARMOUNT,series beam
-to retain a module in the direction' indicated,'.
Assemble mid clamp with one Unirad 1/4"720 T -bolt and one'/4'-20
ASTM F594 serrated flange -nut.
Use anti -seize and tighten to 1 0,ft-lbs of tb'rqd6',.
Resistance factors and safety factors are determined "according. o
'part 1 section 9 of the 2005 Aluminum Design Manual and third -
party test results from an IAS accredited laboratory
Applied Load,
Direction
.'Average
Ultimate
=lbs (N)
Allowable Sifety
Load Factor,,:
;)bs,(N) FS
Design
Load
lbs(N)
Resistance-,
Factor,,,
4Y
Tension, Y+,
Tension, Y+
891 (3963) 2.27
1348 (5994)
0.667
Transverse Z±'l
520 (2313)f
229 (1017)** 2 27-
1 346 (1539)
-0.665
I Sliding, X
1*1'94 (5312),
490 (2179) 2.44
741, (3295)
0.620
Di_ s'Oecified in inches'un unless noted
imension
PERM [T
1j7lnC0UNWY DEVELOPMENT SERV Ic
SOLARMOUNT End'Cla M*P'
IEVIEWED F0
Part,No. 302OOlCi3O2oO2c,,,3O2002D,302003C,
302'003D,302004C,302004D,302005C,302005D,-
CODE COMP
LW
Tension, Y+
1321 (5876),
302006C 302006D,302007D,302008C,302008D,
302009C,302009D,302010C,302011C,302012C-
13�
"End clamPW tr,
ud a mium
PW rial. 0 tkefoll0"W1iTg_ex r6,d a F, u
800(3557) -
alloys:,600.5'-T5, 6105-T5, 6061 J6
Transverse; Z±
U Itimate tensile: 38ksi,Yield: 35 ksi
14:(61)
Fihish:.'Clear or Dark -Anodiz'ed.:
End clamp weight: varies based 'ori height: lbs
21 (92)1
".
-0.058 (26g),
'
`(630)
142 `(6370
52 (231).
Clamp.
Allowable and design loads are valid when comp one nts:,are,
0.555
assembled according to authorized ONIRA'C documents
Value represent the 'allowable and desig i' ad'
Values n,o capacity of a single
end 61a,mp-assembly when used With a SOLARMOUNT. series beam'
to retain a module'in the directi6n indicated
Assemble with one_,Uhirac,1/4"-20 T -bolt and one %%20ASTM F594
Bea
serrated, flange nut,
Use anti -seize and tighten to IQ ft -lbs of,torque
Resistance factors and safety.fact6rs are determined according to
part tsection 9 of the 2005Aluminum Design Manual and -third-,
Y,
' party results n a&
test rultfm a1AS,cee e ab r i
dit d, i o a ory
L ►X
Modules must be installed at least'l.5 in - from either end of a beam
IS
Load
Average
Allowable
�ifeity'
Design
Resistance
MINIMUM
Di ction
Ultimate
Load
`-Factor,
.. i ,
HEIW
VARIES
Dimensions
=11
iffin—mirm
Applied
16S (N)
lbs (N)
:F�
Loads
lbs (N)
Factor,
r
Tension, Y+
1321 (5876),
529 (2352)
'2.60
800(3557) -
Transverse; Z±
63 (279).,.,-
14:(61)
4.58
21 (92)1
0,330
I.Sliding, ,X-_
`(630)
142 `(6370
52 (231).
�'_79 (349)
0.555
SOLARMOUNT Beam Connection Hardware
SOLARMOUNT L -Foot
Part No. 304000C, 304000D
Y
t—► X
Dimensions specified in inches unless noted
::�UNIRAC
A HIM GROUP COMPANY
• L -Foot material: One of the following extruded aluminum alloys: 6005-
T5, 6105-T5, 6061-T6
• Ultimate tensile: 38ksi, Yield: 35 ksi
• Finish: Clear or Dark Anodized
• L -Foot weight: 0.215 lbs (98g)
• Allowable and design loads are valid when components are
assembled with SOLARMOUNT series beams according to authorized
UNIRAC documents
Foot For the beam to L -Foot connection:
• Assemble with one ASTM F593 W-16 hex head screw and one
ASTM F594 Wserrated flange nut
• Use anti -seize and tighten to 30 ft -lbs of torque
• Resistance factors and safety factors are determined according to part
1 section 9 of the 2005 Aluminum Design Manual and third -party test
results from an IAS accredited laboratory
NOTE: Loads are given for the L -Foot to beam connection only; be
sure to check load limits for standoff, lag screw, or other
attachment method
Applied Load
Direction
Average
Ultimate
lbs (N)
Allowable Load
lbs (N)
Safety
Factor,
FS
Design
Load
lbs (N)
Resistance
Factor,
m
Sliding, Z±
1766 (7856)
755 (3356)
2.34
1141 (5077)
0.646
Tension, Y+
1859 (8269)
707 (3144)
2.63
1069 (4755)
0.575
Compression, Y-
13258 (14492)
1325 (5893)
2.461
2004 (8913)
0.615
Traverse, X±
1 486 (2162)
213(949)1
2.28
323 (1436)
0.664
PERMIT # _�:5-" M"67—
BUTTE
"67_...
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED FOR
CODE COMPE
DATE BY
-SOLARMOUNT PUNIRAC
- - A HILTI GROUP COMPANY
•�' 'SOLARMOUNT Beams
a
t Part No. 310132C, 310132C -B, 310168C, 310168C -B; 310168D,-
310208C,
10168Dr 310208C, 310208C -B, 310240C, 310240C -B, 3102401D,,� ' { ,
.,.�410144M, 410168M, 410204M, 410240M t
Properties r.
; Units
SOLARMOUNT
SOLARMOUNT HD
Beam Height
in
2.5
3.0
Approximate Weight (per linear ft)
' }plf
r 0.811
1.271
Total Cross Sectional Area
- ` int
0.676
1.059
Section Modulus (X -Axis)
in3:'
0.353 •
0.898
Section Modulus (Y -Axis) }
•' iin3
0.113
0.221
Moment of Inertia (X -Axis),
in
0.464
'1.450
Moment of Inertia (Y -Axis)
,in°
0.044
0.267
Radius of Gyration (X -Axis)
in
0.289
1.170",
r
Radius of Gyration (Y -Axis)
-. in
0.254 '
0.502
'Rails are extruded using these aluminum alloys: 6005-T5, 6105-T5, 6061-T6
r ice' •• , '+Y -� �, - ''
�t a
Tr-s,•� �i� .. y'tri• �+ r .- • .. ...�. . � t -e r4 ",.t- �Jr, f�T ,�(,• tT� `'�,. f rt,-� � -.. f£ �.� {� v ,,,., -
SLOT FOR T -BOLT OR'
SLOT FOR T -BOLT OR 1'728
V4 HEX HEAD SCREW
V4 HEX HEAD SCREW
•
2X.SLOT FOR SLOT FOR
BOTTOM CLIP 2.500 BOTTOM CLIP '
' ' . • ,''. � , '`• ,' ..3.000, - r
AL
1.316
SLOT FOR
3/8" HEX BOLT SLOT FOR •� �-' ' 1.385 f ",r
3/8" HEX BOLT .r
,• 1.1
' .387
r 750 s 4 1.207 i i_
Y .: x1.875 ,
Y
-
SOLARMOUNT Beam t SOLARMOUNT HD Beam
PERMIT #
BUTTE COUNTY DEVELOPMENT SERVICES '
Dimensions specified in inches unless noted
R EVI EW E ® FOR
COP = COMPLIANCE '
DATE �TiZ7Y a
January 13, 2014
UniRac
1411 Broadway Boulevard NE
Albuquerque, New Mexico 87102-1545
TEL: (505) 242-6411
FAX: (505) 242-6412
R�ESS/pNgl,
H
jqc Fye
�Lu
No. 53878
Pik
rgTSTRUCTo,- -
F OF CA�F.. '
Attn.: Engineering Department,
Re: Engineering Certification for UniRac's SolarMount Code -Compliant Installation Manual 227.3
PZSE, Inc. -Structural. Engineers has reviewed UniRac's "SolarMount Code -Compliant Installation Manual
227.3" published January 2014 and specifically "Part I. Procedure to Determine the Design Wind Load", and
"Part II: Procedure to Select Rail Span and Rail Type".
The procedures are used to determine the calculation of the design wind force, load combinations, applied
loading and rail selection. All information, data and analysis contained within the Installation Manual are based
on, and comply with the following:.
1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05 and ASCE/SEI 7-10
2. 2012 International Building Code, by International Code Council, Inc.
3. 2013 California Building Code, by California Building Standards Commission
4. 2010 Aluminum Design Manual, by The Aluminum Association
This letter certifies that the structural calculations contained within UniRac's "SolarMount Code -Compliant
Installation Manual 227.3 are in compliance with the above Codes.
If you have any questions on the above, do not hesitate to call.
Sincerely,
Paul Zacher, SE - President PERMIT# i f 9Z
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED FOR
- C®3GOMPBY � E
DATE,L A �__
8131 Sunset 6venue Suite`f20 • ,Fniri?aks, CA 95b28 9.16:96139b0 91 b 961;3965 f' ;.1 WwW PISS (ON `
i�v,WARNING,L
ELECTRIC SHOCK HARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH THE LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION
ID WARNING D
BIPOLAR PHOTOVOLTAIC ARRAY
DISCONNECTION OF NEUTRAL
OR GROUNDED CONDUCTORS
MAY RESULT IN OVERVOLTAGE
OF ARRAY OR INVERTER
?HOTOVOLTAIC SYSTEM
AiDC DISCONNECT Af
PERATING VOLTAGE VDC
DERATING CURRENT -AMPS
AX SYSTEM VOLTAGE - VDC
CRT CIRCUIT CURRENT
JH I A , RGE CONTROLLER MAX
AMPS
AMPS
PHOTOVOLTAIC SYSTEM
D AC DISCONNECT Q
OPERATING VOLTAGE
VOLTS
OPERATING CURRENT AMPS
AC DISCONNECT
PHOTOVOLTAIC SYSTEM
DISCONNECT
DC DISCONNECT
PHOTOVOLTAIC
SOLAR BREAKER
CAUTION SOLAR CIRCUIT
=� v- . .