Loading...
HomeMy WebLinkAboutB15-1990 000-000-000r 383 Rio Lindo Ave, Chico, CA 95926 p. (530) 592-4407 www.summitchico.com Structural Calculations For: Client: Kyle Keesling BUTTE COUNTY project: JUN 0 f 2016 Keesling Residence Carports DEVELOPMENT Address: SERVICES Breeze Hollow Lane, Oroville, CA 81s`)g00 rq�O1NEDYeG��c� ��c C 88 M . EXP. t q CNIL � \OF CAUF� r IIRILF�#i 16- Ec� 1 Eo bul (F -COUNTY DEVELOPMENTsERVIGES '!.MEWED FOR ! 3b ltp By—k--)- Note: Y__1N Note: Summit Structural Design (SSD) is not responsible for on-site inspection to assure compliance with the standards, sizes, materials, or workmanship specified herein. SSD is not responsible for any structural element or system not specifically noted in this set of specifications/calculations unless authorized in writing by SSD. Workmanship shall be of the highest quality and in all cases shall follow accepted construction practice, the latest edition of the California Building Code, and local building department standards. STRUCTURAL NOTES I I 1. GENERAL A) ALL WORK SHALL CONFORM TO THE 2013 CBC AND ALL APPLICABLE LOCAL CODES. B) THE ENGINEER (SUMMIT STRUCTURAL DESIGN) IS RESPONSIBLE FOR THE STRUCTURAL ITEMS IN THE PLANS ONLY. THE GENERAL CONTRACTOR SHALL VERIFY THAT ALL CONSTRUCTION IS IN FULI AGREEMENT WITH THE LATEST, BUILDING DEPARTMENT APPROVED, STRUCTURAL DRAWINGS. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIED IN THESE CALCULATIONS WITHOUTTHE WRITTEN APPROVAL FROM THE ENGINEER, THEN THE ENGINEER WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE. C) THE DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE, AND, UNLESS SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE METHOD OF CONSTRUCTION, AND SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, AND THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE FORMING, SHORING, BRACING, SCAFFOLDING, ETC. D) IF A PARTICULAR FEATURE OF CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN THE CALCULATIONS, THEN IT SHALL BE CONSTRUCTED IN THE SAME CHARACTER AS SIMILAR CONDITIONS THAT ARE SHOWN ON THE DESIGN DOCUMENTS. E) ANY CONDITIONS NOTED AS EXISTING MUST BE FIELD VERIFIED BYTHE CONTRACTOR, AND ANY DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER WITHOUT PROCEEDING WITH CONSTRUCTION PRIOR TO THE REVIEW OFTHE ENGINEER. I F) ALL WATER PROOFING AND FLASHING (ROOFS, FOUNDATIONS, GARAGE FLOORS, ETC...) IS THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. G) SPECIAL INSPECTION: SPECIAL INSPECTION PER SECTION 1701 OF THE CBC SHALL BE PROVIDED FOR THE FOLLOWING TYPES OF CONSTRUCTION: WELDING OF STRUCTURAL OR REINFORCING STEEL THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE STRUCTURAL ENGINEER AND BUILDING DEPARTMENT, SHALL BE ICBO QUALIFIED, AND THEIR EXPERIENCE SHALL BE COMMENSURATE WITH THIS TYPE OF PROJECT, 2. SITE WORK / FOUNDATIONS j A) ASSUMED MAXIMUM SOIL BEARING = 1,500 PSF PER CBC TABLE 1804.2. I B) BUILDING SITE IS ASSUMED TO BE DRAINED AND FREE OF CLAY OR EXPANSIVE SOIL. ENGINEER HAS NOT MADE A GEOTECHNICAL REVIEW OF SITE, ANY OTHER CONDITIONS ENCOUNTERED MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER, C) THESE CALCULATIONS ASSUME STABLE, UNDISTURBED SOILS AND LEVEL OR STEPPED FOOTINGS. ANY OTHER CONDITIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO THE CONSTRUCTION OF THE FOUNDATIONS. j D) ALL FOOTINGS INCLUDING RETAINING WALL FOOTINGS, SPREAD FOOTINGS, WALL FOOTINGS, AND GRADE BEAMS SHALL BEAR ON UNDISTURBED SOIL WITH A FOOTING DEPTH BELOW FROSTLINE. E) BOTTOM OF ALL FOUNDATION TRENCHES SHALL BE CLEAN AND LEVEL. F) ALL FINISHED GRADE SHALL SLOPE AT A MINIMUM SLOPE OF 5% AWAY FROM ALL FOUNDATIONS A MINIMUM OF 10 FEET HORIZONTAL. G) FOUNDATIONS SHALL NOT BE SCALED FROM PLAN OR DETAIL DRAWINGS. H) FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND OTHER FOREIGN SUBSTANCES, AND SHALL BE COMPACTED A MINIMUM OF 90%. I) USE 4" DIAMETER PERFORATED PIPE SUB -DRAIN BEHIND ALL RETAINING WALLS. SLOPE PIPE TO DRAIN TO DAYLIGHT. J) FOR FOOTINGS PLACED ON OR ADJACENT TO SLOPES, A GEOTECHNICAL ENGINEER MUST APPROVE FOOTING PLACEMENTS IN VIOLATION OF FIGURE 1808.7.1 OF THE 2013 CBC. THIS ENGINEER SHALL NOT BE LIABLE FOR ANY FOUNDATION NOT IN STRICT CONFORMANCE TO SECTION 1808 OF THE 2013 C6C. K) WHERE LOADING TO EXISTING FOUNDATIONS IS NOT SUBSTANTIALLY INCREASED OR MODIFIED, NO DESIGN RECOMMENDATIONS HAVE BEEN MADE FOR THE SUITABILITY OF THE EXISTINGfOUNDATIONS. ONLY THOSE FOUNDATIONS WHERE LOADS HAVE BEEN ADDED BY A SECOND STORY HAVE BEEN INCLUDED IN THE DESIGN. THE OWNER SHALL BE ADVISED THAT EXISTING FOUNDATIONS MAY NOT BE STRUCTURALLY ADEQUATE AND SETTLEMENT, CRACKING, AND OTHER PROBLEMS ASSOCIATED WITH EXISTING FOUNDATIONS ARE BEYOND THE SCOPE OF THIS DESIGN. IF REVIEW OF THE EXISTING FOUNDATIONS IS REQUIRED, A GEOTECHNICAL ENGINEER SHOULD BE CONTACTED TO DETERMINE THE EXTENT AND ADEQUACY OF THE EXISTING, UN -MODIFIED PORTIONS OF THE FOUNDATIONS AND UNDERLYING SOILS. i 1 I -, L mmit Structural D PRO1E 4. CONCRETE / REINFORCING A) CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 2,500 PSI U.N.O. C) ALL CEMENT USED SHALL CONFORM TO ASTM C-150 AND SHALL BE TYPE II OR TYPE III LOW ALKALI, D) AGGREGATE SHALL CONFORM TO ASTM C-33 AND SHALL NOT CONTAIN MATERIALS THAT ARE ALKALI REACTIVE AS DETERMINED BY ASTM C-227, 289, AND 295. IF TEST DATA IS UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE CEMENT WITH A MAXIMUM ALKALI CONTENT LESS THAN 0.45% BY WEIGHT. E) CONCRETE EXPOSED TO FREEZING OR THAWING SHALL BE PROTECTED IN ACCORDANCE TO THE LATEST EDITION OF ACI 318. F) SLABS ON GRADE SHALL BE PER THE CONTRACTOR. SUMMIT STRUCTURAL DESIGN RECOMMENDS THE FOLLOWING AS A SUITABLE SLAB -ON -GRADE: AT GARAGE SLABS, USE 4" THICK S.O.G. WITH #3 BARS AT 15" O.C. EACH WAY ABOVE MID -DEPTH OF SLAB OVER 2" SAND, OVER MOISTURE BARRIER, OVER 4" AGGREGATE BASE. USE 3-1/2" SLAB WITH #3 AT 15" E.W. ABOVE MID -DEPTH OF SLAB, OR 6X6 WWF ABOVE MID -DEPTH OF SLAB WITH SAME SUB sLAE1 BUILDUP AT ALL OTHER AREAS. G) SAW -CUT TOP %" OF SLAB FOR CRACK CONTROL AT INTERVALS NOT TO EXCEED 16'-0" WHERE SLAB IS REINFORCED, SAW CUT AT INTERVALS NOT TO EXCEED 7'-0" WHERE SLAB IS UN -REINFORCED'. 1) REINFORCEMENT COVER SHALL BE AS FOLLOWS: CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 3" CONCRETE WITH SOIL OR WEATHER EXPOSURE: #5 BARS AND SMALLER: 1 Ya" #6 BARS AND LARGER: 2" CONCRETE WITHOUT SOIL OR WEATHER EXPOSURE: %" J) REINFORCEMENT SHALL BE GRADE 60 PER ASTM A615 U.N.O. LAP BOTTOM BARS 60 BAR DIAMETERS U.N.O. AND LAP TOP BARS, PLACED ABOVE 12" OF CONCRETE OR MORE, 80 BAR DIAMETERS U.N.O. K) #5 AND LARGER REBAR SHALL NOT BE RE-BENT. L) ALL REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND ADEQUATELY SECURED IN POSITION BEFORE AND DURING CONCRETE PLACEMENT. 6. FRAMING/LUMBER 6-1 MATERIALS: A.) SHEATHING: 1. ROOF SHEATHING: Y" APA RATED 32/16 EXPOSURE 1, STRUCTURAL SHEATHING WITH FACE GRAIN PERPENDICULAR TO FRAMING, STAGGER PANELS AND NAIL WITH 8d AT 6" O.C..EDGE, 12" O.C. FIELD U.N.O. PROVIDE 1/8" GAP AT ALL PANEL EDGES U.N.O. BY PANEL MANUFACTURER, 2. FLOOR SHEATHING: %" APA RATED 48/24 WITH FACE GRAIN PERPENDICULAR TO FRAMING, STAGGER PANELS AND NAIL WITH 10d AT 6" O.C. EDGE 10" O.0 FIELD, GLUE AND NAIL TO ALL SUPPORTS. PROVIDE 1/8" GAP AT ALL PANEL EDGES U.N,O, BY PANEL MANUFACTURER. 3, WALL SHEATHING: SEE PLANS 4. ANY SHEATHING WITH EXTERIOR EXPOSURE SHALL BE OF EXTERIOR TYPE. B.) GLUE -LAMS: GLUE -LAMS SHALL BE 24F -V4 U.N.O. WITH A CAMBER OF R=1600' O.N.O. GLUE -LAMS EXPOSED TO WEATHER MUST BE RATED FOR EXTERIOR USE BY THE MANUFACTURER. FLASHING AND WATERPROOFING OF EXPOSED ENDS SHALL BE PROVIDED BY THE CONTRACTOR TO PREVENT DECAY. GLUED LAMINATED FABRICATION SHALL BE PERFORMED IN AN APPROVED FABRICATOR'S SHOP IN ACCORDANCE WITH CBC 2303.1.3, AITC A190.1 AND ASTM D 3737. BEAM INSPECTION CERTIFICATES SHALL BE SUBMITTED TO THE FIELD INSPECTOR PRIOR TO COMPLETION OF FRAME INSPECTION IN ACCORDANCE WITH CBC 1704.2. C.) MICRO -LAMS: MICRO -LAMS (LAMINATED VENEER LUMBER) SHALL HAVE FB = 3100 PSI & FV = 285 PSI MIN., AND SHALL BE MANUFACTURED, APPROVED AND IDENTIFIED AS PER NER-481 C2.) PARALAMS: PSL'S (PARALLEL STRAND LUMBER) SHALL HAVE FB = 2900 PSI & FV ',= 290 PSI MIN., AND SHALL BE MANUFACTURED, APPROVED AND IDENTIFIED AS PER NER-481 D.) SILL PLATES: SILL PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR WITH 1/2". DIAMETER ANCHOR BOLTS AND 3" X 3" X.229" THICK PLATE WASHERS LOCATED AT 6'-0" O.C. MAX. WITH ONE BOLT LOCATED 1'-0" MAXIMUM FROM EACH END OF EACH PIECE. AT SHEAR WALL LOCATIONS, SILLS SHALL BE 3X MATERIAL UNO PER PLANS AND DETAILS. E.) FRAMING LUMBER: ALL FRAMING LUMBER SHALL BE DOUGLAS FIR LARCH AS GRADED BY THE W.W.P.A. OR W.C.L.I.B. AND SHALL HAVE A MOISTURE CONTENT LESS THAN 19%, U.N.O. 1. STUDS SHALL BE STUD GRADE OR BETTER. 2. ALL POSTS SHALL BE DF -L #1 U.N.O. 3, 2X AND 3X RAFTERS SHALL BE DF -L #2 U.N.O. 4. 2X JOISTS SHALL BE DF -L #2 U.N.O. 5. CONCEALED BEAMS SHALL BE DF -L #2 esline Caroorts 6, EXPOSED BEAMS SHALL BE DF -L ##1 APPEARANCE GRADE FREE OF HEART CENTERS (4X6 AND LARGER) F.) NAILS: ALL NAILS SHALL BE COMMON U.N.O. WHERE EXPOSED TO WEATHER OR WITHIN 18" OF FOUNDATION, NAILS SHALL BE HOT DIPPED GALVANIZED. G.) BOLTS AND LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O. AND PROVIDED NEW AND WITHOUT EXCESSIVE RUST. BOLTS EXPOSED TO WEATHER SHALL BE GALVANIZED. H.) ALL HARDWARE CALLED SHALL BE SIMPSON STRONG -TIE CO., OR ENGINEER APPROVED EQUIVALENT, INSTALLED PER MANUFACTURER'S RECOMMENDATIONS WITH ALL HOLES FILLED WITH RECOMMENDED FASTENERS I.) ALL METAL FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE STAINLESS STEEL OR OTHERWISE CERTIFIED BY THE MANUFACTURER TO RESIST CORROSION CAUSED BY THE SPECIFIC TREATMENT APPLIED TO WOOD, 6-2 GENERAL FRAMING A,) MINIMUM NAILING: MINIMUM NAILING SHALL BE PER 2013 CBC TABLE 2304.9.1. B.) LARGER MEMBERS: ALL FRAMING MEMBERS SPECIFIED IN THESE CALCULATIONS ARE MINIMUMS; LARGER MEMBERS MAY BE SUBSTITUTED AT CONTRACTOR'S OPTION, C.) SHRINKAGE: CARE SHALL BE TAKEN TO ALLOW FOR EFFECTS OF SHRINKAGE, WHICH COULD CAUSE SETTLEMENT OF ROOF AND OR FLOORS AND COULD LEAD TO FAILURE OF ASSOCIATED FRAMING MEMBERS. THE CONTRACTOR SHALLTAKE ALL MEASURES NECESSARY TO PROTECT FRAMING FROM THE EFFECTS OF SHRINKAGE. 6-3 BEAM FRAMING A.) BUILT UP BEAMS: ALL BUILT UP, LAMINATED DOUBLE OR MULTIPLE 2X JOISTS AND BEAMS SHALL BE NAILED TOGETHER WITH 16d NAILS AT 6" O.C., T&B U.N.O. B.) DOUBLE JOISTS: PROVIDE DOUBLE FLOOR JOISTS UNDER PARTITION WALLS RUNNING PARALLEL TO JOIST SPAN AND UNDER ALL LOCATIONS WHERE TUBS MAY BE LOCATED, ADEQUATE SUPPORT SHALL BE PROVIDED FOR ALL OTHER EQUIPMENT OR FURNISHINGS WHICH MAY NOT BE SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING BUT NOT LIMITED TO: HOT WATER HEATER, STOVE, REFRIGERATOR, OVEN, FIRE PLACE ENCLOSURES, WOOD BURNING STOVE, ETC... C.) BLOCKING: PROVIDE SOLID BLOCKING IN JOIST FRAMING ABOVE ALL SUPPORTS AND MIDSPAN OF JOISTS SPANNING GREATER THAN 10'-0" 6-6 CONNECTIONS A.) HOLES FOR THROUGH BOLTS SHALL BE DRILLED 1/16" OVERSIZE. B.) ALL BOLTS, NUTS, AND LAG SCREWS SHALL BE PROVIDED WITH FLAT OR MALLEABLE WASHERS WHERE BEARING AGAINST WOOD. C.) ALL BOLTS AND LAG SCREWS SHALL BE TIGHTENED UPON INSTALLATION AND RE -TIGHTENED BEFORE CLOSING IN OR AT COMPLETION OF JOB. D.) LAG SCREWS SHALL BE SCREWED, NOT DRIVEN, INTO PLACE. E.) FASTENERS IN PRESERVATIVE OR FIRE RETARDANT TREATED WOOD SHALL BE HOT DIPPED GALVANIZED. 7. STEEL 7.1 STRUCTURAL STEEL A.) STRUCTURAL STEEL: ROLLED STEEL SHAPES, PLATES, AND BARS SHALL CONFORM TO ASTM A-36. WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A-992. B.) STRUCTURAL TUBES: STRUCTURALTUBES SHALL CONFORM TO ASTM A-500 GRADE B. C.) ALL WELDING SHALL BE ELECTRIC ARC WELDING, AND SHALL BE PERFORMED ONLY BY EXPERIENCED, QUALIFIED WELDERS. ELECTRODES SHALL BE E60 XX FOR METAL DECK AND E70 XX OTHERWISE, UNLESS SPECIFICALLY NOTED OTHERWISE. WELDING SHALL CONFORM TO AWS D1.1. D.) UNSPECIFIED WELDS: WELDS NOT SPECIFIED SHALL BE CONTINUOUS FILLET WELDS. WELD SIZE SHALL BE PER RISC SPECIFICATIONS FOR THE THICKER PART OF THE JOINT, E.) ALL STEEL SHALL BE SHOP PAINTED, UNLESS ENCASED IN CONCRETE, GROUTED MASONRY, OR SPRAYED FIREPROOFING, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. F.) BOLTS AND LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O. AND PROVIDED NEW AND WITHOUT EXCESSIVE RUST. 8-2 CUT AND STACKED ROOF FRAMING, A,) CUT AND STACKED ROOF SYSTEMS SHALL BE BUILT TO THE CONVENTIONAL FRAMING REQUIREMENTS OF THE CALIFORNIA BUILDING CODE (CBC 2308.10). PURLINS, BRACES, INTERMEDIATESUPPORTS, AND CONNECTIONS Summit Structural Design PROJECT: Keesling Carar�rts __� �l SHALL BE PROVIDED BY THE CONTRACTOR THAT ARE CAPABLE OF TRANSMITTING ALL GRAVITY AND WIND LOADS TO THE FOUNDATION. B.) IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE CONVENTIONALLY FRAMED ROOF SYSTEM WITH TIES AND SUPPORTS BRACING ALL ELEMENTS TO THE FOUNDATION. THE ENGINEER HAS MADE A CURSORY REVIEW OF THE FRAMING SIZES AND SUPPORT LOCATIONS, AND HAS PROVIDED GENERAL CONNECTION DETAILS TO COVER THE MAJORITY OF CONDITIONS, BUT HAS NOT PROVIDED ENGINEERING DETAIL REQUIREMENTS FOR ALL CONNECTIONS NECESSARY FOR THE ROOF TO PERFORM IN ACCORDANCE WITH THE LOADING CRITERIA, IF ANY SPECIFIC ELEMENT OF THE ROOF FRAMING SYSTEM IS NOT SHOWN AND DETAILED CONNECTION CRITERIA IS REQUIRED, PLEASE CONTACT THE ENGINEER FOR ADDITIONAL INFORMATION. 9. DESIGN LOADS A) ALL DESIGN LOADS ARE PER CBC CHAPTER 16, DIVISIONS I, II, III, AND IV U.N.O. B) ROOF LIVE LOAD : 20 PSF REDUCIBLE C) SEISMIC ZONE: D D) WIND SPEED: 110 MPH EXP C Summit Structural Design Project: Keesling Carports Engineer: RKB Design of : Gravity Loads Roof Slope= 6 to 12 Roof Dead Load Ply 1.5 psf Roofing 2.5 psf Framing 2.0 psf Clg 2.0 psf Insul 0.0 psf Misc. 1.4 psf Total (sloped) 9.4 psf Total (horiz) 10.0 psf Roof Live Load Roof Live Load 20.0 psf 2X8 BARGE BD.�^ POOP rpl MING NOTE5 li 1. ROOF DESIGN - ROOF RAFTERS AT 2'-0" - 15# FELT - METAL ROOF - SNOW LOAD 0# 2. H2.5 ANCHORS AT EACH RAFTER 2X6 RAFTERS ® 24" O.C. TYP. I + ill 6:12 6:12 H2.5 ANCHOR ALL RAFTERS TYP. 2X BLOCKING BETWEEN RAFTERS I � l► 2X8 BARGE BD.�^ Summit Structural Design Project: Keesling Carports Engineer: RKB Design of: Seismic Mass and Seismic Load Development Area (ft2) Weight (Ibs) Roof 1008 10070 Roof Snow (20%) 0 0 Height (ft) Length (ft) Weight (Ibs) Walls(ext) 8.5 0 0 Walls(int) 8.5 0 0 Total 20070 Roof Area (ft 2) Floor Area (ft) Ultimate Working Stress 1008 0 2121 1515 Roof Trib Wall Line Area (f' Typ HSS 158 Line Shear (Ibs) Working Stress 238 Shear (Ibs) rho Total 1.00 238 x� Gole. gle earth feet; 1000 meters h = I N rvIA I Cv. r C m uesign maps summary Keport i Design Maps Summary Report User -Specified Input Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data avallable in 2008) Site Coordinates 39.480N, 121.46°W Site Soil Classification Site Class D - "Stiff Soil" USGS-Provided Output SS = 0.598 g SMS = SI = 0.257 g SMI = 0.790 g SIDS = 0.527 g 0.484 g SDI = 0.323 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2.009 NEHRP" building code reference document. MCER Response Spectrum 0.83-- 0.90-- 0.72 .az0.800.?2 o.r>4 0.56 0.49-- L M .48to 0.40 0.32 0,24.- 0.1G .240.10 0.03 0.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2,00 Period, T (sec) Design Response Spectrum 0,54-- 0.4e 0,42-- 0.3c .420.36 M 0.30 N 0.2b 0.18 '""•-....'--,.. 0.l z 0,06 0.00 t-+--+-----�--� 0.00 0.20 0.40 0.60 0.80 1.00 1.70 1.40 1.60 Lt0) 2,00 Period, T (sec) Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. http://ehpl-earthquake.cr.usgs.gov/designMaps/us/summary.php?template=minimal&tatitude=39.48&longitude=-121.46&siteclass=3&riskcateaorv=08d-ditinn=i .. 1/1 N Summit Structural Design Project: Keesling Carports Engineer: RKB Design of: Seismic Load Development (ASCE 7-10) Ss 0.598 Mapped 0.2 sec spectral response S1 0.2.57 Mapped 1 sec spectral response Site Class D �► In accordance with Ch 20. SMS 0.79 Max Considered EQ SM1 0.48 Max Considered EQ SDS 0.527 Design Spectral Response (0.2 Sec) SD1 0.323 Design Spectral Response (1.0 Sec) Y Cantilever Columns — T System R 2.5 Omega 1.25 Cd Cs 0.21 12.8-2 Max Cs 0.79 Ct 0.028 x 0.8 Ta 0.16 Cu 1.4 Max T Use T 0.16 Alt Ss 0.598 V= 0.211 *W Height to Roof (hn) _ V= 2.1 k Vert Dist Exp. (k) Seismic Design Category D Occupancy 2 1 1 TL 16 2.5 Ht Limit 35 Min Cs 0.02 (.01 outside of SJ) 0.23 No limit for drift 9 ft 1 Level Story Ht. (ft) hi (ft) wi (kips) (wi*hi) (kip -ft) Cvx Veq (kips) S VEQ (kips) _ Dia_ph. (kips) ROOF 9 9 10 91 1.00 2.1 2 2 10.1 91 Summit Structural Design Project: Keesling Carports Engineer: RKB Design of: MWFRS-Envelope Procedure (ASCE 7-10, Section 28.6) Conditions: r. •'� K� rr� 1. Simple Diaphragm r,-� CASE D 2. Low-rise- z-) -1- �•i2 3. Enclosed `Yr l-rl 4. Regular Shaped ` S. Not Flexible r� 6. Not Subject to: CASE A r ' a) across wind loading b) vortex shedding c) instability(gailup/flutter) yam, d) channeling effect n g � ' /� i :i �/f e) buffeting (upwind obstructions) ---• r''r l� 7. Approx. 5 metrical Cross Section With Flat, Gable, or Hip Roof <_ 45 8. Exempt From Torsional Load Cases -'�x Indicated in Note 5 of Fig. 28.4-1, or :r J ' the Torsional Load Cases do not ^• /. VAE •. 011 S"`A Control the Design: CASE COY=' ,Q. -Jl � r' o`a- (1) story and h<_30 ft. or "' (2) story max and light framed or (2) story max and flex. diaphragm L= 50 Long. Bldg. Dim. (ft) 2aL= 8.0 ft. T= 40 Transv. Bldg. Dim. (ft) 2aT= 8.0 ft. V= 110 Basic Wind Speed (110 or 115 mph) LCF= 0.60 Load Combination Factor N= 1.21 Adjustment Factor Kz1= 1.00 Topographic Factor Adjustment Factor for Bldg Height and h= 12 Mean Roof Height (ft) Exposure, N 0= 25 Closest Roof Angle Mean Roof Exposure (5°,10°,150,20°,25°,or 30') Ht. (ft) B C D MWFRS Wind Loads (psf), ps=LCF*N*Kzt*ps30 15 1.00 1.21 1.47 Location ps, 0=0 ps, 0=25 Min. Net Ovhg. 20 1.00 1.29 1.55 A-110 13.9 17.5 9.6 25 B-1.10 2.8 4.8 30 1 7.70- 1.40 1.6 C-1.10 9.2 12.6 9.6 35 1.05 1.4 1.7() D-1.10 2.9 4.8 40 1.09 1.49 1.74_ E-110 -16.8 -7.8 -14.4 45 1.12 1.53 1.78 F-110 -9.5 -10.6 50 1.16 1.56 1.81 G-17--11. - -12.3 55 1.19 1.59 H-110 -7.3 -8.5 60 1 1.22 1.62 1.f31 11 Summit Structural Design Project: Keesling Carports Engineer: RKB Desian of: C+C-Envelope Procedure (ASCE 7-10, Section 30.5) C) ` { 1` 0 ���' C.) U l0 r;t; �.. ' J HIP ROOF (7'c. e !�25* HIP ROOF (25'< e _<_27') `31� G3�� {i) 0", �;) 01 ✓� o.�; ,' o...• Yom, -• -' `"- FLAT ROOF and CABLE ROOF (7'< D<151 GAQi E ROOF ((•)<,7') L= 50 Long. Bldg. Dim. (ft) a(ft) = 4.0 T= 40 Transv. Bldg. Dim. (ft) V=: 110 Basic Wind Speed (110 or 115 mph) LCF= 0.6 Load Combination Factor A= 1.21 Adjustment Factor Kzt= 1 Topographic Factor h= 12 Mean Roof Height (ft) RAN= 2 Roof Angle Number 0=0°-7° 2=8°-27° 3=28°-45° Conditions: 1. Mean Roof Height 5 60 ft. 2. Enclosed _ -- 3. Regular Shaped 4. Not Subject to: _ ��- a) across wind loading b) vortex shedding ---- c) instability (gallup/flutter) d) channeling effect e) buffeting (upwind obstructions) 5. Flat Roof or Gable Roof < 45°, or Hip Roof < 27° Adjustment Factor for Bldg 1 g Height and Exposure, h can Roof Ht. Exposure ft B C 15 1.00 1.21 _-I� 1.47 20 1.00 1.29 -1.55 25 1.00 1.35 -1.61 30 1.00 1.40 1.66 35 1.05 1.45 40 1.09 1.49 _1.70 1.74 45 1.12 1.53 1.78 50 1.16 1.56_ 1.81 55 1.19 1.59 1.84 60 1.22 1.62_ 1.87 C+C Wind Loads (psf), pnet=LCF*AIIKzt*pnet3o Loc. Zoneft2 EWA pnet Ovhg. + _ _ Loc, EWA pnet Zone ft + 0 �0 6 - 4.4 10 15.8 _ 2 .6 - 4 20 �5. _T7.1 I fi.4 1 50 11.6 -13.5 4 50 14.2 1 f5.5 1 100 11.6 -13.1 4 100 13,4 -14.8 2 10 11.6 -25.2 -29.5 4 500 11.8 -13.1 2 11-6---n,2 - . 5 10 15.8 -21.1 2 50 ----2U 5 -29.5 5�_'I 2 00 11.6 - 8.5 -29.5 4.9 5 .2 T'l 3 10 11.6 -37.2 -49.6 5 100 13.4 16.4 3 20 11.6 -34.8 -44.7 5 500 11.8 -13.1 3 100 11.6 -29.2 -33.5 I'S Summit Structural Design Project: Keesling Carports Engineer: RKB Design of: Cantilever Column Steel Code Check for Structural Tubing Per ANSI/AISC 360 _ Properties Loads Member Length, L = 7.5 ft Axial Load, Ppt - 0.91 kips K = 2.1 Axial Load, Pit = 0.00 kips Yield Stress, Fy = 46.0 ksi Seismic Wind Modulus of Elasticity, E = 29000 ksi Shear, Vx = 0.24 0.59 kips Height, In = 4.00 in. VY = 0.00 0,00 kips Width, w = 4.00 in. Wall thickness, t = 0.23 in Note: Radius of Gyration, rx = 1.52 in See lateral design for Seismic and Wind Radius of Gyration, ry - 1.52 in load development, Area, A = 3.37 int Section Modulus, Sx = 3.90 In3 Section Modulus, Sy = 3.90 In3 Moment of Inertia, Ix = 7.80 Ino Section O.K. Moment of Inertia, ly = 7.80 in4 Zx = 4.69 ln3 Zy = 4.69 in4 Compression Section ok for Compression Critical Load Combination, P = 0.91 kips < 15% of Allowable - Section ok for Cantilever Column W, 1.670 4.71'(E/Fy)^(1/2)= 118.261 x-axis y axis KI/r = 124.24 124.24 Fe = 18.542 ksi 18.542 ksi Fcr = 16.4464232 ksi 16.4464232 ksi Pn = 55.4415137 kips 55.4415137 kips Allowable Compressive Strength Pn/Wc - 33.1985112 kips 33.1985112 kips Bending Section ok for Bending Wb 1.670 x-axisy axis Seismic Bending Moment, M = 21.42 k -in 0.00 k -in Wind Bending Moment, M = 53.10 k -In 0.00 k -in Compact Compact Nominal Flexural Strength, Mn 215.74 k -In 215.74 k -in Allowable Flexural Strength, Mn/Wb 129.19 k -in 129.19 k -in Shear Section ok for Shear Wv 1.670 kv 5 x-axis y-axis Q= 3.42 in3 3.42 in3 Cv = 1 1 Aw - 1.43 in2 1.43 Int Design Shear Stress, fv - VO/It 0.72 ksi 0.00 ksi Nominal Shear Strength, Vn - 39.46 kips 39.46 kips Allowable Shear Strength, Vn/W„ = 23.63 kips 23.63 kips Combined Bend & Comp. Section okfor Combined Egns. Pr/Pc 0.03 Eqn 1-11.1b 0.180 Deflection Section ok for Deflection Calculated Deflection, DMAX = 0.390 in. Allowable Deflection, DALLOW - 2.250 In Summit Structural Design Project: Keesling Carports Engineer: RKB Design of : Post Foundations, Constrained Constrained Embed Depth, d= 4.43 ft. b= 2.0 ft. Diameter of round post or diagonal dimension of square post. h= 7.0 ft. Height of applied load. P= 595 lbs. Applied load. S3= 450 psf Allow. lateral bearing pressure based on embed depth. ..._ - -- - — _ .... _._ _. _ ._. _ _�_... - -- _......_._._....... . _ .__..._.... ..._..._... MoL 14. Summit Structural Design Project: Keesling Carports Engineer: RKB Design of: Roof Framing (Conventional) Roof Loads DL= 10 psf LL= 20 psf Roof plywood: 1/2" APA rated Exterior plywood or OSB. Apply face grain perpendicular to framing, stagger panels and nail with 8d at 6" o.c. edges and 12" o.c. field. Edge nail at gable ends, drags strap lines, blocking, and all supported edges. COMPANY PROJECT Summit Structural Design WoodWorks' May 24, 2016 16:22 sesnvnxr FOR woos nesrex 61 Design Check Calculation Sheet WoodWorks Sizer 10.1 Loads: Load Type Distribution Pat- Location (ft) Magnitude Unit 922 922 Roof Live tern Start End Start End fb _ 1.cad1 Uea;l Full /.rea .559 i5ary 10.00 (7.00)+ psf Loa" 12 wird C&C Full Area V, in re 'd 1.00' 20.00 17.00)' psf Load3 of constr. Full Area 0.26 - L/614 16,00 ;7,00)• psf Self -weight. Dead Full VDL pLf Maximum Reactions (lbs) and Bearing Lengths (in) 13'-2" 13'-1" unfactorl'd: -- Value Dead 522 522 Wind 922 922 Roof Live 630 8.30 Fac?:orad: fb 714 Total -- 1559 .559 i5ary 0,08 <L/999 ring: Length -.--_ 1.00' 1.'or: V, in re 'd 1.00' ,OCA' rvununuin -'ry ienyui s wfy usvu I fur enu 5upperl5 Lumber -soft, D.Fir-L, No.2, 4x12 (3.1/2"x11-1/4") Supports: All - Timber -30(t Beam, D.Fir-L No.2 Total length 13'-2.0'; Lateral support: top= 24 bottom= ai supports; (in) Analysis vs. Allowable Stress (psi) and Deflection (in) „Sing NDS 2012: Criterion Anal 5is Value Design Value Anal si5/Desion St:aar fv - 44 Fv' _ ' Z fv Fv 0.19 DencJing (+) fb 714 Fib • 1'2 fb/Fb' - 0.88 Dead Defl'n 0,08 <L/999 Live Defl'n 0.1.4 a <L/994 0.44 a L/360 0.32 'Total Def.1.'n 0.26 - L/614 0.65 L/240 0.39 Additional Data: FACTORS: F/E(Psi1CU CM CC CL CF Cfu Cr Cfrt Ci Cn LCN Fv' 160 1.25 1.00 1.00 - - - - 1,00 1.00 .1.00 2 Fb'+ 900 1.25 1,00 1,00 0.996 1.100 1.00 1.00 1.00 1.00 - 2 Fcp' 625 - 1,00 1.00 - - - - 1.00 1.00 - - 1.6 million 1.00 1.00 - - - - 1.00 1.00 - 0 Efrin' 0,58 million 1.00 1.00 - - - - 1.00 1.00 - 3 CRITICAL LOAD COMBINATIONS: Shea rLC 02 D+Lr, V = 1.343, V design 1142 lbs 0endingl+): LC N2 - D+Lr, t! - 4394 lbs -ft Deflet.tion: LC N3 - D+,75(Lr+.42w) (live) LC 03 = D+.75(Lr,.42W) (total.) D -dead L., ve 5asnow W=wind 1 -impact Lr -roof live Lc®concentrated E=earthquake All LC's are listed in the Analysis output Load Carrbinations: ASCE '7-10 / 18C 22, CALCULATIONS: Da'.iectl:n Fa - 664,06 lb -int. "Live° deflection a Deflection from all nun -dead lnaris Ilivr., wind, sno.....i ;'oval ,^..eflect ion m 1.50{Dead Lcad Detier-t Toru Live Load Daflert ion. Design Notes: 1 WoodWoiks analysis and design are in accordance with the ICC International Building Code (IBC 2012), the National Design Specification (NDS 2012), and NDS Design Suoplernent 2 Please verify that the default deflection limits are appropriate for your application. 3 Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. COMPANY PROJECT Summit Structural Design WoodWorlss' May 2n, 2016 16:2702 w4 Design Check Calculation Sheet �! Wood Works Sizer 10.1 l_r1Ari51 Load TypeU1 u[rlbution PaC- I.uL•:,t ion (ftl Hannitude Unit i'i7 4J Reef I.1 CCYn SCart End start End th Loaf Dead FL Ar._a ,• a__ gr 10- �-- -- Load2 wind c'C '.1, Arca .in req'd 1.01) 20.00 129.01' pet Loa" Recf --t'. Full A, 0.61 L/219 18.00 {24.01' psC e_C-we1 ht. U'ad Full UD L 2.0 >1C Maximum Reactions (ibs) and Bearing Lengths (in) 11'•23' gSli Unfaccmed. lAnalyis �-^ ^----- Uaad 121 sis/De n Wind i'i7 4J Reef I.1 5<nd;no nrl th 1143 Tocaf 742 ,• a__ gr o.th9 '• �-- -- Length 1.00• l.:i r.• .in req'd 1.01) 1•"'�• `M,Nmum heal no lentil 01,n used,. i• for end st, + ons Lumber -soft, D.Fir-L, No.2, 2x6 (1-i/2"x5-1/2") Supports: All - Timber -soft Beam, D.Fir-L 140.2 Roof Joist spaced at 24,0' cicf Total length, 1 V-2.7% Pilch: 8/12: Lateral support: top': full, bottom= full: Repetitive factor: applied where permitted (refer to online help); Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2012: cl,i lAnalyis Valu' Desl n Vaiut•Annl sis/De n Sncar tv > 4J 5<nd;no nrl th 1143 Fb' • 1602 Cb/ilr' 0.60 D"d Uvtl'n o.th9 '• L/646 Ll v,+ Defl'n 0.33 > L/J00 b. 55 • I./2i0 0.60 To�nl Defl'e. 0.61 L/219 0.73 • Ll1,Q 0.84 Additional Data: FACTORS: %S(Pso CD C. Ct CL CF Cfu Cr Cfrt Ci C LCp el 100 1.25 1.00 ].00 - 1.00 2 Fb'. :ioo 1.25 i.0'0 1.00 1.000 1.300 1.00 1.is 1.00 1.00 - 2 F 625 - 1.00 1.00 - - - 1.00 3.Do - - E' l.6 m'71 ion 1.00 1.00 - - - 1.00 1.00 3 Ern: n' 0.58 million 1.00 1.00 - - - - 1.00 1.00 - 3 CRITICAL LOAD COMBINATIONS: .hear : LC N2U+Lt, V 264, v design 240 lbs Gendi ng l•i: LC 42 D•L[, M • 720 ibs-ft Defluct ion: LC pl • D•.751Lr•.92cr1 iilvej LC al Us.75(L-4214) (total) ATI 1.•live S•snow w"wind I -impact Lt+root live Le -concentrated E-earthquak, nil LC'a ale 1l aced in the Ana lys l.s output li corr> tioua: ASCE 7-10 / ]UC 2012 CALCULATIONS. Deflecci an: EI • 31'06 lb-in2 "L1 va^ deflection 01,Cl ccc icn from all non -&tad load:: ili-, wind, Tocaf Deflactian 1.50(Dead Load Dofloccior) • Live Load Ueflectlon. 3oarin7 Al!ewa Il, boa tiny sit en angle F"chats calculated for tach support a per NDS 1.10.1 Design Notes: 1. WoodWorKs analysis And design are in accordance with the ICC International Building Code (IBC 2012), the National Design Speciricalion (NDS 2012), and NDS Design Supplement. 2. Pleaso verify that the default deflection limits are appropriate for your application. 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 4. SLOPED BEAMS: level bearing Is required for all sloped beams. 5. FIRE RATING: Julius. wap studs, and multi -ply members are not rated for fire endurance. Design Check Calculation Sheet Wood Works Sizor 10,1 Lnadsi ;cad 7yp< Dl ttlbuUoa COMPANY PROJECT ,(. Oq:G cndl Summit Structural Design Full' Area . rWoodWorks' "�''•; .00( ,, 0'J1• May 24, 2016 16:26 137 Roof rouser. .SOFT14'ARf rnR WOOD nrS1Ck' e96 D¢act Vili 20.00117.001• Design Check Calculation Sheet Wood Works Sizor 10,1 Lnadsi ;cad 7yp< Dl ttlbuUoa Pa G- ttl rn I.ocatlon iftl Start End Ma qui rude start. End Oq:G cndl woad Full' Area 170 "�''•; .00( ,, 0'J1• Ps Lcad2 Roof rouser. Full Acea e96 D¢act Vili 20.00117.001• paf Loads Daad Full Area Hearing: ..anq rh 1.00• 17. Go115. 00!• Ps( Load•1 Doad Fuil Aa ea l.Cv.• eL/999 15.00 (7.001• ref Load$ Liva Full Area 40.00 (7,001• pat Load6 0uad Full Area 10.00 15.001. paf Load' Wind Full Acea 20.00 15,001' Pa. Load Roo( collate. Full Area 1o.00 15.001. paf soli-wnl }IG Dnad F.11 VOL 9.5 if Maximum Reactions (lbs) and Bearing Lengths (in) 4'.2' Unfactoced: Analvefa ^---^ I D¢ainn Daad1511 JAII.1y. Ie/Daai In S ear 1511 Li va563 Fv' 170 "�''•; wlr:n toe 268 Roof Live e96 D¢act Vili G`'6 To Gat 27il -------" 2714 Hearing: ..anq rh 1.00• �L/999 i•0`'• min req 1.'o• � l.Cv.• I n­1111ry u cu. l ,u. c.iu ¢uyyu..a Timber -soft, D.Fir-L, No.2, 6x8 (5.112"x7.1/4") Suppons: All • Timber -soft Boom, D.Fir•L No.2 Tot al length: 4'•2,0'; lateral support: lop= at supports, bottom= at supports; Analvsis vs. Allowable Stress (psi) and Deflection (in) uslnq NDS 2012: Cri Carlo Analvefa value I D¢ainn value JAII.1y. Ie/Daai In S ear tv S Fv' 170 lv t'v' 0.31 Hnndingl•1 III522 tb' • 750 tb/tb' • 0.70 D¢act Vili 0.02 • ell". Live Detln 0.02 �L/999 0.14 L/360 0.12 Tccal 0cf1'n 0.05 • eL/999 0.20 • L/240 0.22 Additional Data: FACTORS: F/EIpa11C0 CK Cc CL CF Cfu Cr Cfet Ci Co LCe Fv' I7U 3.00 1.00 1.00 - - - 1.00 1.00 1.00 Fb'♦ 750 ] AO 1.00 3.00 1.000 1.000 1.00 3.00 1.00 1.00 - Z 1" 625 - 1.00 LOo - - - - 1.00 1.00 E' 1.3 mi l l Ion 1.00 1.00 - - - - 1.00 1.00 - 4 CRITICAL LOAD COMBINATIONS: SM•art LC ¢2 • D -L, V - 20`.3, V doargn • 1401 lb¢ Hendingl•YI LC 02 ^ 0•L, M 2096 1ba-tt De f loctiont LC e4 ^ D•,754L.Lr•. G;a1 (livr'r LC 04 . D•.151L-L[,.6v1 (total) Dadaad L -live S^ano�.+ w•w•ind I-ingrnct. Lr --f l-,L-conerntrated 6^aacthqua Y.¢ Ail !':'n are ilstrtl !n the h aly¢'e output Loan C -LI 1,10na: ASCE ^-I0 / IH< 2012 CAXLJLATIONS: Uar 1¢ct'.ion: EI • 227".01• Ib -int deft set ton Oetl¢ecien teorrroll-load loads rlivc, wind, snow..1 Torai Deflection 1.5010eaU Load Uoflert soul • Llve Load D¢G1".,,tics. Design Notes: 1 Wooci analysis and design are in accordance with the ICC International Building Code (IBC 2012), the National Design Specification (NDS 2012). and NOS Design Supplement. 2. Please verify Thal the default retortion limits aro appropriate for your application. 0. Sawn lumber bonding mernbors shall be laterally supported according to the provisions of NDS Clause 4.4.1. z 0 z GENERAL NOTES 1. ALL LUMBER TO BE DOUG FIR #2 AND BETTER, STUDS TO BE STUD GRADE OR BETTER, UNLESS OTHERWISE NOTED FLOOR PLAN SII CARPORT: 400 SQ. FT. X2 Wul N01F,5 a.) PRIOR TO BUILDING PERMIT FINAL APPROVAL THE PROPERTY SHALL BE IN COMPLIANCE WITH THE VEGETATION CLEARANCE REQUIREMENTS PRESCRIBED IN CALIF. FIRE CODE SECTION CRC R327.1.5. b.) WHERE THE ROOF PROFILE ALLOWS A SPACE BETWEEN THE ROOF COVERING AND ROOF DECKING, THE SPACES SHALL BE CONSTRUCTED TO PREVENT THE INTRUSION OF FLAMES AND EMBERS, BE FIRE STOPPED WITH APPROVED MATERIALS OR HAVE ONE LAYER OF MINIMUM 72# MINERAL SURFACED NON—PERFORATED CAP SHEET COMPLYING WITH ASTM D39909 INSTALLED OVER THE COMBUSTIBLE DECKING. CRC R327.5.2. C.) WHEN PROVIDED, VALLEY FLASHINGS SHALL NOT BE LESS THAN 26 GAUGE GALV. SHEET CORROSION—RESISTANT METAL INSTALLED OVER NOT LESS THAN ONE LAYER OF MINIMUM 72#MINERAL SURFACED NON—PERFORATED CAP SHEET COMPLYING WITH ASTM D3909, A MINIMUM OF 36" WIDE RUNNING THE FULL LENGTH OF THE VALLET. CRC R327.5.3. d.) ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND DEBRIS IN THE GUTTER. CRC R327.5.4. e.) ROOF, ATTIC AND UNDERFLOOR VENTS SHALL BE DESIGNED TO RESIST THE INTRUSION OF FLAME AND EMBERS THROUGH THE VENTILATION OPENINGS, OR SHALL BE PROTECTED BY CORROSION—RESISTANT, NON—COMBUSTLBLE WIRE MESH WITH A MINIMUM OF 1/16" AND A MAXIMUM OF 1/8" OPENINGS. CRC R327.6.2. f.) EAVE OR CORNICE VENTS SHALL NOT BE INSTALLED UNLESS THEY ARE DESIGNED TO RESIST THE INTRUSION OF FLAME AND BURNING EMBERS INTO THE ATTIC AREA, OR IF THE ATTIC SPACE BEING VENTED IS FULLY SPRINKLERED. CRC R327.6.3. 9.) EXTERIOR WINDOWS, WINDOW WALLS, GLAZED DOORS, AND GLAZED OPENINGS IN DOORS SHALL BE INSULATING GLASS UNITS WITH A MINIMUM OF ONE TEMPERED PANE, OR GLASS BLOCK UNITS, OR HAVE A FIRE RESISTANCE RATING OF NOT LESS THAN 20 MINUTES WHEN TESTED ACCORDING TO NEPA 257. CRC R327.8.2.1. h.) EXTERIOR DOORS SHALL BE OF APPROVED NONCOMBUSTIBLE OR IGNITION RESISTANT MATERIAL OR SOLID CORE WOOD HAVING STILES AND RAILS NOT LESS THAN 1.375 INCHES THICK WITH INTEROR PANELS NO LESS THAN 1.25 INCHES THICK OR SHALL HAVE A FIRE—RESISTANCE RATING OF NOT LESS THAN 20 MINUTES. CRC R327.8.3. i.) EXTERIOR WALLS: THE EXTERIOR WALL COVERING OR WALL ASSEMBLY SHALL BE OF NONCOMBUSTIBLE MATERIAL, OR IGNITION—RESISTANT MATERIAL, OR HEAVY TIMBER OR LOG WALL CONSTRUCTION. CRC R327.7.3. j.) EXTENT OF EXTERIOR WALL COVERING: EXTERIOR WALL COVERINGS SHALL EXTEND FROM THE TOP OF THE FOUNDATION TO THE ROOF, TERMINATING AT 2" NOMINAL SOLID WOOD BLOCKING BETWEEN RAFTERS AT ALL ROOF OVERHANGS, OR TERMINATING AT THE ENCLOSURE OF ENCLOSED EAVES. CRC R327.7.3.1. k.) OPEN ROOF EAVES: THE EXPOSED ROOF DECK ON THE UNDERSIDE OF UNENCLOSED ROOF EAVES SHALL CONSIST OF NONCOMBUSTIBLE MATERIAL, OR IGNITION —RESISTANIT MATERIAL OR 1 LAYER 5/8" TYPE 'X' GYPSUM SHEATHING APPLIED BEHIND AN EXTERIOR COVERING ON THE UNDERSIDE EXTERIOR OF THE ROOF DECK, OR THE EXTERIOR PORTION OF A 1—HOUR FIRE RESISTIVE ASSEMBLY APPLIED TO THE UNDERSIDE OF THE ROOF DECK. 'CRC R327.7.4. I.) THE DECKING MATERIAL SHALL BE IN ACCORDANCE WITH CRC SEC. R327.9 AND THE EXTERIOR PORCH CEILINGS ARE TO BE EITHER IGNITION RESISTANT OR NON—COMBUSTIBLE PER CRC SEC. 327.7.6. BUTTE COUNTY JUN 0 6 2016 1..)EVELOPMENT SERVICES R's -1990 p1n Chi. u U—OCCUPANCY V—B CONSTRUCTION SCOPE OF WORK: CONSTRUCT 2 NEW 1 STORY WOOD & IRON FRAMED CARPORTS(400 SQ. FT EA.) ON EACH SIDE OF EXISTING CONSTRUCTION, PERMIT #: B15-1990 ALL WORK ON THIS PROJECT SHALL CONFORM TO THE ADOPTED EDITIONS OF THE 2013 CBC, 2013 CRC 2013 CMC 2013 CPC , THE 2013 CALIF. ELECT. CODE 2013 CALIF. ENERGY STANDARDS & 2013 GREEN BUILDING STANDARDS CODE OCCUPANCY IS RESIDENTIAL TYPE OF CONSTRUCTION IS WOOD FRAME FOUNDATION PLAN STRUCTURAL NOTES: 1.) SEE TYPICAL NOTE SHEET SN AND TYPICAL DETAIL SHEET SD1 FOR ADDITIONAL INFORMATION. 2.) RECOMMENDED MINIMUM SLAB SECTION: A— 4" CONCRETE SLAB WITH #3 AT 15" O.C. SECURELY LOCATED AT MID—DEPTH OF SLAB. B— 2" SAND (DELETE AT EXTERIOR SLABS)—SEE SOILS REPORT IF APPLICABLE. C— WATERPROOF MEMBRANE (DELETE AT EXTERIOR SLABS)—SEE SOILS REPORT IF APPLICABLE. D— 4" FREE DRAINING MATERIAL—SEE SOILS REPORT IF APPLICABLE. E— PROPERLY PREPARED SUBGRADE—SEE SOILS REPORT IF APPLICABLE. F— CONTRACTOR TO PROVIDE CONTROL JOINTS AT 10'-0" O.C. EA. WAY MAX. 3.) TYPICAL ROOF SHEATHING (UNO): 1/2" THICK, APA, TECO, OR PITTSBURGH RATED SHEATHING, SPAN RATING 32/16, EXPOSURE 1 STRUCTURAL PANELS, APPLIED WITH LONG DIMENSION ACROSS SUPPORTS AND ADJACENT PANELS STAGGERED WITH 4' ENDS OFFSET 4'. EDGE NAIL WITH 8d COMMON OR EQUIVALENT (0.131" DIA X 2 1/2") AT 6" O.C. AT ALL PANEL EDGES, BOUNDARIES, GABLE ENDS, BLOCKING AND WHERE INDICATED ON PLAN. FIELD NAIL AT 12" O.C. PROVIDE 1/8" GAP AT ALL PANEL EDGES U.N.O. BY PANEL MANUFACTURER. AT ALL LOW SLOPE ROOFS PROVIDE (1) PANEL CLIP MIN. BETWEEN SUPPORTS AT ABUTTING PANEL EDGES. 4.) ANY DISCREPANCIES BETWEEN FRAMING/FOUNDATIONS SHOWN AND FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ENGINEER OF RECORD. 5.) ALL EXPOSED FRAMING SHALL BE PRESSURE TREATED WITH TREATMENT PROCESS AND APPLICATION APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S WRITTEN GUIDELINES. 6.) ALL STRUCTURAL MEMBERS SHALL BE FASTENED IN COMPLIANCE WITH 2013 CBC FASTENING SCHEDULE, TABLE 2304.9.1, UNLESS NOTED OTHERWISE. `v EDYB6 `N C 78 1 EXP. Q*33=01t CML THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS F'E ;U11T #:` BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR- CODE OR COD COMPLIAf G »ATF. '?BY—VA DRAWN BYi B. RUBANOFF CHECKED: DATE: 5-1-16 � SCALE: W Z � 1/4"=1'-0" U.N.O. J❑B; Q L N J CD J rn 0 z F 4 I J N 2 w W w J M 0 >O � `W Q � �' m O Q DRAWN BYi B. RUBANOFF CHECKED: DATE: 5-1-16 SCALE: 1/4"=1'-0" U.N.O. J❑B; KEESLING J SHEET # 1 F 4 5 SD1 TYP. ROOF FRAMING PLAN 2X8 BARGE BD. J H2.5 ANCHOR ALL RAFTERS BLOCK BETWEEN RAFTERS OPEN ROOF EAVES REQUIRE NONCOMBUSTIBLE OR IGNITION RESISTANT MATERIALS SUCH AS FIRE RESISTANT PLY. OR FIRE RESISTANT OSB IN ACCORDANCE WITH 2013 CRC SECTION 327.7.4 STRUCTURAL NOTES: 1.) SEE TYPICAL NOTE SHEET SN AND TYPICAL DETAIL SHEET SD1 FOR ADDITIONAL INFORMATION. 2.) RECOMMENDED MINIMUM SLAB SECTION: A- 4" CONCRETE SLAB WITH #3 AT 15" O.C. SECURELY LOCATED AT MID -DEPTH OF SLAB. B- 2" SAND (DELETE AT EXTERIOR SLABS) -SEE SOILS REPORT IF APPLICABLE. C- WATERPROOF MEMBRANE (DELETE AT EXTERIOR SLABS) -SEE SOILS REPORT IF APPLICABLE. D- 4" FREE DRAINING MATERIAL -SEE SOILS REPORT IF APPLICABLE. E- PROPERLY PREPARED SUBGRADE-SEE SOILS REPORT IF APPLICABLE. F- CONTRACTOR TO PROVIDE CONTROL JOINTS AT 10'-0" O.C. EA. WAY MAX. 3.) TYPICAL ROOF SHEATHING (UNO): 1/2" THICK, APA, TECO, OR PITTSBURGH RATED SHEATHING, SPAN RATING 32/16, EXPOSURE 1 STRUCTURAL PANELS, APPLIED WITH LONG DIMENSION ACROSS SUPPORTS AND ADJACENT PANELS STAGGERED WITH 4' ENDS OFFSET 4'. EDGE NAIL WITH 8d COMMON OR EQUIVALENT (0.131" DIA X 2 1/2") AT 6" O.C. AT ALL PANEL EDGES, BOUNDARIES, GABLE ENDS, BLOCKING AND WHERE INDICATED ON PLAN. FIELD NAIL AT 12" O.C. PROVIDE 1/8" GAP AT ALL PANEL EDGES U.N.O. BY PANEL MANUFACTURER. AT ALL LOW SLOPE ROOFS PROVIDE (1) PANEL CLIP MIN. BETWEEN SUPPORTS AT ABUTTING PANEL EDGES. 4.) ANY DISCREPANCIES BETWEEN FRAMING/FOUNDATIONS SHOWN AND FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ENGINEER OF RECORD. 5.) ALL EXPOSED FRAMING SHALL BE PRESSURE TREATED WITH TREATMENT PROCESS AND APPLICATION APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S WRITTEN GUIDELINES. 6.) ALL STRUCTURAL MEMBERS SHALL BE FASTENED IN COMPLIANCE WITH 2013 CBC FASTENING SCHEDULE, TABLE 2304.9.1, UNLESS NOTED OTHERWISE. FLASH AT ALL ROOF/ WALL CONNECTIONS PROPOSED CARPORT 4" CONC. SLAB 6X6 10/10 W.W.M. 6 MIL V.B. 2" SAND 4" GRAVEL FILL 18"DIAM..X60" DEEP CONC. FTG W/ POST H EMBEDDED 4'-0" EXISTING oahComb,,s+ CONSTRUCTION AINPLY. Yve5i5t,;^� SAWN @ PORCH SOFFIT MIN 5/8" APA RATED PLYWOOD WITH 8D (0.113 x 2 3/8") NAILS AT 6" O.C. EDGE NAILING, AND 12" O.C. FIELD NAILING. SECTION A -A C7 8 � EXP. /302Olt sTA��� � �'<Fo��•" 6 �ti JI l THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS LEDGER ATTACHMENT: 1/4"X6" SDS SCREWS 0 16" O.C. INTO TOP & BOTTOM 1 3/4" LVL RIM OF LVL RIM & BLOCKING 2X BLOCKING---, —2X8 P.T. LEDGER 2X6 RAFTERS Q 24' O.C. 12 1/2" CCX PLY. @ EAVES 2X8 FASCIA BD. PROPOSED \�3 1/2"X14" PSL BEAM TYP. CARPORT A- WOLMINIZED IF NECESSARY � _I 4" CONC. SLAB 6X6 10/10 W.W.M. 6 MIL V.B. 2" SAND 4" GRAVEL FILL a - PERMIT# GUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR � CODE COMPL.IA :.. DATE <q-.-30-1 � RY 2 SD1 TYP. 3 P00F TAMING NOT�5 1. ROOF DESIGN - ROOF RAFTERS AT 2'-0" - 15# FELT - METAL ROOF - SNOW LOAD 0# 2. H2.5 ANCHORS AT EACH RAFTER 4 SD1 TYP. 2X6 DF.#2 RAFTERS ® 24" O.C. TYP. Q li W Co Q m N J U-) � °a z o i J 6:12 6:12 H2.5 ANCHOR ALL RAFTERS TYP. J J N SD1 TYP. Y 0 U 2X BLOCKING BETWEEN RAFTERS M J LTJ J 0 N _j .. L,J O Q � m O Q 5 SD1 TYP. ROOF FRAMING PLAN 2X8 BARGE BD. J H2.5 ANCHOR ALL RAFTERS BLOCK BETWEEN RAFTERS OPEN ROOF EAVES REQUIRE NONCOMBUSTIBLE OR IGNITION RESISTANT MATERIALS SUCH AS FIRE RESISTANT PLY. OR FIRE RESISTANT OSB IN ACCORDANCE WITH 2013 CRC SECTION 327.7.4 STRUCTURAL NOTES: 1.) SEE TYPICAL NOTE SHEET SN AND TYPICAL DETAIL SHEET SD1 FOR ADDITIONAL INFORMATION. 2.) RECOMMENDED MINIMUM SLAB SECTION: A- 4" CONCRETE SLAB WITH #3 AT 15" O.C. SECURELY LOCATED AT MID -DEPTH OF SLAB. B- 2" SAND (DELETE AT EXTERIOR SLABS) -SEE SOILS REPORT IF APPLICABLE. C- WATERPROOF MEMBRANE (DELETE AT EXTERIOR SLABS) -SEE SOILS REPORT IF APPLICABLE. D- 4" FREE DRAINING MATERIAL -SEE SOILS REPORT IF APPLICABLE. E- PROPERLY PREPARED SUBGRADE-SEE SOILS REPORT IF APPLICABLE. F- CONTRACTOR TO PROVIDE CONTROL JOINTS AT 10'-0" O.C. EA. WAY MAX. 3.) TYPICAL ROOF SHEATHING (UNO): 1/2" THICK, APA, TECO, OR PITTSBURGH RATED SHEATHING, SPAN RATING 32/16, EXPOSURE 1 STRUCTURAL PANELS, APPLIED WITH LONG DIMENSION ACROSS SUPPORTS AND ADJACENT PANELS STAGGERED WITH 4' ENDS OFFSET 4'. EDGE NAIL WITH 8d COMMON OR EQUIVALENT (0.131" DIA X 2 1/2") AT 6" O.C. AT ALL PANEL EDGES, BOUNDARIES, GABLE ENDS, BLOCKING AND WHERE INDICATED ON PLAN. FIELD NAIL AT 12" O.C. PROVIDE 1/8" GAP AT ALL PANEL EDGES U.N.O. BY PANEL MANUFACTURER. AT ALL LOW SLOPE ROOFS PROVIDE (1) PANEL CLIP MIN. BETWEEN SUPPORTS AT ABUTTING PANEL EDGES. 4.) ANY DISCREPANCIES BETWEEN FRAMING/FOUNDATIONS SHOWN AND FIELD CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ENGINEER OF RECORD. 5.) ALL EXPOSED FRAMING SHALL BE PRESSURE TREATED WITH TREATMENT PROCESS AND APPLICATION APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S WRITTEN GUIDELINES. 6.) ALL STRUCTURAL MEMBERS SHALL BE FASTENED IN COMPLIANCE WITH 2013 CBC FASTENING SCHEDULE, TABLE 2304.9.1, UNLESS NOTED OTHERWISE. FLASH AT ALL ROOF/ WALL CONNECTIONS PROPOSED CARPORT 4" CONC. SLAB 6X6 10/10 W.W.M. 6 MIL V.B. 2" SAND 4" GRAVEL FILL 18"DIAM..X60" DEEP CONC. FTG W/ POST H EMBEDDED 4'-0" EXISTING oahComb,,s+ CONSTRUCTION AINPLY. Yve5i5t,;^� SAWN @ PORCH SOFFIT MIN 5/8" APA RATED PLYWOOD WITH 8D (0.113 x 2 3/8") NAILS AT 6" O.C. EDGE NAILING, AND 12" O.C. FIELD NAILING. SECTION A -A C7 8 � EXP. /302Olt sTA��� � �'<Fo��•" 6 �ti JI l THESE PLANS HAVE BEEN REVIEWED FOR COMPLIANCE ONLY WITH THE ATTACHED STRUCTURAL CALCULATIONS LEDGER ATTACHMENT: 1/4"X6" SDS SCREWS 0 16" O.C. INTO TOP & BOTTOM 1 3/4" LVL RIM OF LVL RIM & BLOCKING 2X BLOCKING---, —2X8 P.T. LEDGER 2X6 RAFTERS Q 24' O.C. 12 1/2" CCX PLY. @ EAVES 2X8 FASCIA BD. PROPOSED \�3 1/2"X14" PSL BEAM TYP. CARPORT A- WOLMINIZED IF NECESSARY � _I 4" CONC. SLAB 6X6 10/10 W.W.M. 6 MIL V.B. 2" SAND 4" GRAVEL FILL a - PERMIT# GUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR � CODE COMPL.IA :.. DATE <q-.-30-1 � RY DRAWN BY: B. RUBANOFF CHECKED: DATE: 5-1-16 SCALE: 1/4"=1'-0" U.N.O. JOB: KEESLING SHEET # 2 4 Q li W Co Q m N J U-) � °a z o i J � LL W J J N Q Y 0 U LdW M J LTJ J 0 N _j .. L,J O Q � m O Q DRAWN BY: B. RUBANOFF CHECKED: DATE: 5-1-16 SCALE: 1/4"=1'-0" U.N.O. JOB: KEESLING SHEET # 2 4 LEFT ELEVATION ;CIA BD. FRONT ELEVATION REAR ELEVATION 111r - RIGHT ELEVATION PEM,A:TCF �;UTTE COUNTY DEVE� MENFO IR PEVIEWED ` NG PD ins �;— DATE DRAWN BY: B, RUBANOFF CHECKED: DATE: 5-1-16 SCALE; 1/4"=V-0" U.N.O. JOB: KEESLING SHEET # 3 OT 4 1 475.00' O J O S w N w w crm 475.00' 1202.00' 745.96' 5r; GUTTER WITH ABILITY TO PREVENT THE ACCUMULATION OF LEAVES i (N) DOWNSPOUT OPTION 1: UNDERGROUND RETENTION SYSTEM DO N5POUT DAPTER 10' MIN 2% 1 BACKFILL (E) GUTTER 18" CO & SWEEP 4" HDPE N-12 CLOSED PIPE 25 LF 4" PERF PIPE 6" WRAPPED IN FILTER CO & TEE FABRIC (PERFORATION DOWN) IN DRAIN ROCK. OPTION 2: GRASSY SWALE (9 (E) FENCE 2% MIN.�` 8 (E) a DE WA L K % \\ 6' L 4' 6" 10' GRASSY SWALE WATER RETENTION OPTIONS 75' 75' 75' 20' m PERMIT# BUTTE COUNTY DEVELOPrnFNT SERVICES REVIEWED FOR .` CWE COI PI_IANIO LEACH LINES m• DRAWN BY: B. RUBANOFF CHECKED: DATE: 5-1-16 SCALE: � W � KEESLING /-3 Z Q SHEET # N 4 OF 4 O �J:�o z O W o J � N w w O J w W J - .. V w O0 Q Of r m O Q DRAWN BY: B. RUBANOFF CHECKED: DATE: 5-1-16 SCALE: 1/4"=1'-0" U.N.O. JOB: KEESLING /-3 �.. SHEET # 4 OF 4 GENERAL STRUCTURAL NOTES 1. GENERAL 3. CONCRETE / REINFORCING CONTINUED A) ALL WORK SHALL CONFORM TO THE 2013 CBC AND ALL APPLICABLE LOCAL CODES. 1) REINFORCEMENT COVER SHALL BE AS FOLLOWS: B) THE ENGINEER (SUMMIT STRUCTURAL DESIGN) HAS PROVIDED AND IS RESPONSIBLE FOR ADJ CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 3" LLH SPECIFIC STRUCTURAL ITEMS ONLY. ALL OTHER REQUIREMENTS OF THE BUILDING CODE ALT CONCRETE WITH SOIL OR WEATHER EXPOSURE: LLV INCLUDING WATERPROOFING, FIREPROOFING, DRAINAGE, HANDICAP ACCESSIBILITY, EGRESS ARCH #5 BARS AND SMALLER 1 Y�" LONG REQUIREMENTS, PARKING, AND ALL OTHER DESIGN REQUIREMENTS NOT SPECIFICALLY SHOWN BLDG #6 BARS AND LARGER 2" LSL IN THE STRUCTURAL DESIGN CALCULATIONS, ARE THE RESPONSIBILITY OF THE CONTRACTOR OR OWNER. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIED IN THESE BLKG CONCRETE WITHOUT SOIL OR WEATHER EXPOSURE: 3/4" LVL DOCUMENTS WITHOUT THE WRITTEN APPROVAL FROM THE ENGINEER, THEN THE ENGINEER WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE. J) REINFORCEMENT SHALL BE GRADE 60 PER ASTM A615 U.N.O. LAP BOTTOM REINFORCING (60) MAX MAXIMUM BOTT (B) BAR DIAMETERS U.N.O. AND LAP TOP REINFORCING, PLACED ABOVE 12" OF CONCRETE OR C) THE DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE, AND, UNLESS BTF MORE, (80) BAR DIAMETERS U.N.O. MECH SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE METHOD OF CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE FOR THE METHOD OF CONSTRUCTION, AND SHALL PROVIDE ALL K) #5 AND LARGER REBAR SHALL NOT BE RE-BENT. MFR MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, AND THE STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE FORMING, SHORING, L) ALL REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND MIN BRACING, SCAFFOLDING, ETCETERA. CCJ ADEQUATELY SECURED IN POSITION BEFORE AND DURING CONCRETE PLACEMENT. D) IF A PARTICULAR FEATURE OF CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN CIP CAST -IN-PLACE CONCRETE MTL THE CALCULATIONS, THEN IT SHALL BE CONSTRUCTED IN THE SAME CHARACTER AS SIMILAR 6. FRAMING/LUMBER CONSTRUCTION JOINT (N) CONDITIONS THAT ARE SHOWN ON THE DESIGN DOCUMENTS. CLR CLEAR NS NEAR SIDE 6-1 MATERIALS: CONCRETE MASONRY UNITS E) ANY CONDITIONS NOTED AS EXISTING MUST BE FIELD VERIFIED BY THE CONTRACTOR, AND COL COLUMN NTS ANY DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER WITHOUT A.) SHEATHING: OC PROCEEDING WITH CONSTRUCTION PRIOR TO THE REVIEW OF THE ENGINEER. CONN 1. ROOF SHEATHING: SEE PLANS OD OUTSIDE DIAMETER CONSTR 2. FLOOR SHEATHING: SEE PLANS F) ALL WATERPROOFING AND FLASHING (ROOFS, FOUNDATIONS, GARAGE FLOORS, ETC...) IS THE CONT 3• WALL SHEATHING: SEE PLANS OPNG RESPONSIBILITY OF THE CONTRACTOR OR OWNER. CONTR CONTRACTOR OVS OVERSIZE ROUND HOLE B.) GLUE -LAMS: GLUE -LAMS SHALL BE 24F -V4 U.N.O. WITH A CAMBER OF R=1600' U.N.O. G) SHOP DRAWINGS: SHOP DRAWINGS ARE SUPERCEDED BY THE STRUCTURAL DRAWINGS UNDER CTR GLUE -LAMS EXPOSED TO WEATHER MUST BE RATED FOR EXTERIOR USE BY THE MANUFACTURER. PERP ALL CIRCUMSTANCES. THE GENERAL CONTRACTOR SHALL VERIFY THAT ALL CONSTRUCTION IS IN CTSK GLUED LAMINATED FABRICATON SHALL BE PERFORMED IN AN APPROVED FABRICATORS SHOP PL FULL AGREEMENT WITH THE LATEST STRUCTURAL DRAWINGS. REVIEW OF SHOP DRAWINGS BY DBL IN ACCORDANCE WITH CBC 2303.1.3, AITC A190.1, AND ASTM D 3737. BEAM INSPECTION PLWD THE ENGINEER OF RECORD DOES NOT GUARANTEE IN ANY WAY THE THE SHOP DRAWINGS ARE DF CERTIFICATES SHALL BE SUBMITTED TO THE FIELD INSPECTOR PRIOR TO COMPLETION OF FRAME PLCS CORRECT, NOR DOES IT INFER THAT THEY SUPERCEDE THE STRUCTURAL DRAWINGS. DF -L INSPECTION IN ACCORDANCE WITH CBC 1704.2. H) WALL FINISH SYSTEMS SUCH AS STUCCO SHALL BE APPLIED OVER FOAM BASE OR OTHER C.) MICRO -LAMS: MICRO -LAMS (LAMINATED VENEER LUMBER) SHALL HAVE FB = 3100 PSI AND PT METHOD OF ADEQUATELY ALLOWING THE FINISH TO EXPAND AND CONTRACT WITHOUT DJ FV = 285 PSI MIN., AND SHALL BE MANUFACTURED, APPROVED AND IDENTIFIED AS PER NER-481. P/C CRACKING. THE OWNER OR CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEFECTS IN THE EA EACH P/T FINISHES. D.) SILL PLATES: SILL PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR WITH 1/2" DIAMETER REINF REINFORCEMENT EL ANCHOR BOLTS AND 3" X 3" X.229" PLATE WASHERS LOCATED AT 6'-0" O.C. MAX. WITH 1) SPECIAL INSPECTION: SPECIAL INSPECTION PER SECTION 1701 OF THE CBC SHALL BE PROVIDED ELEV ONE BOLT LOCATED V-0" MAXIMUM FROM EACH END OF EACH PIECE. RE -TREAT CUT ENDS SC FOR THE FOLLOWING TYPES OF CONSTRUCTION: EN WHERE REQUIRED. SEOR WELDING OF STRUCTURAL OR REINFORCING STEEL E•) FRAMING LUMBER: ALL FRAMING LUMBER SHALL BE DOUGLAS FIR LARCH AS GRADED BY THE RECORD ES W.W.P.A. OR W.C.L.I.B. AND SHALL HAVE A MOISTURE CONTENT LESS THAN 19%, U.N.O. SHTG THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE STRUCTURAL ENGINEER AND BUILDING (E) EXISTING SIM DEPARTMENT, SHALL BE ICBO QUALIFIED, AND THEIR EXPERIENCE SHALL BE COMMENSURATE EXP 1. STUDS SHALL BE STUD GRADE OR BETTER. SOG WITH THIS TYPE OF PROJECT. EXT 2. ALL POSTS SHALL BE DF -L #1 U.N.O. STD STANDARD EW 3. 2X AND 3X RAFTERS SHALL BE DF -L #2 U.N.O. STIFF STIFFENER FF 4. 2X JOISTS SHALL BE DF -L #2 U.N.O. 2. SITE WORK / FOUNDATIONS FIN 5. CONCEALED BEAMS SHALL BE DF -L #2. SQ SQUARE FJ 6. EXPOSED BEAMS SHALL BE DF -L #1 APPEARANCE GRADE FOHC (4X6 AND LARGER). A) ASSUMED MAXIMUM SOIL BEARING = 1500 PSF PER CBC TABLE 1806.2 (NO SOILS REPORT FLR 7. ALL BEAMS 6X AND LARGER SHALL BE FREE OF HEART CENTER. SWS PROVIDED). F.) NAILS: ALL NAILS SHALL BE COMMON U.N.O. WHERE EXPOSED TO WEATHER OR WITHIN 18" B) BUILDING SITE IS ASSUMED TO BE DRAINED AND FREE OF CLAY OR EXPANSIVE SOIL. ENGINEER FOHC OF FOUNDATION, NAILS SHALL BE GALVANIZED. T&B HAS NOT MADE A GEOTECHNICAL REVIEW OF SITE, ANY OTHER CONDITIONS ENCOUNTERED MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER. G.) BOLTS AND LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O. AND TO(P) TOP OF (PLYWOOD) FS PROVIDED NEW AND WITHOUT EXCESSIVE RUST. C) THESE CALCULATIONS ASSUME STABLE, UNDISTURBED SOILS AND LEVEL OR STEPPED FOOTINGS. ANY OTHER CONDITIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO H.) ALL HARDWARE CALLED SHALL BE SIMPSON STRONG -TIE CO., OR ENGINEER APPROVED TOF THE CONSTRUCTION OF THE FOUNDATIONS. GA EQUIVALENT, INSTALLED PER MANUFACTURER'S RECOMMENDATIONS WITH ALL HOLES FILLED TOS TOP -OF -STEEL GALV WITH RECOMMENDED FASTENERS. USP HARDWARE MAY BE USED IN LIEU OF SIMPSON D) ALL FOOTINGS INCLUDING RETAINING WALL FOOTINGS, SPREAD FOOTINGS, WALL FOOTINGS, GLB HARDWARE WITH WRITTEN APPROVAL FROM STRUCTURAL ENGINEER OF RECORD. ALL METAL TN AND GRADE BEAMS SHALL BEAR ON UNDISTURBED SOIL WITH A FOOTING DEPTH BELOW HDG HANGERS, CONNECTORS, AND FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD SHALL TYP FROSTLINE (12" TO 24" AS PER LOCAL REQUIREMENTS). HDR BE STAINLESS STEEL OR OTHERWISE CERTIFIED BY THE MANUFACTURER TO RESIST CORROSION UNO UNLESS NOTED OTHERWISE HGR CAUSED BY THE SPECIFIC TREATMENT APPLIED TO THE WOOD AND/OR METALS. E) BOTTOM OF ALL FOUNDATION TRENCHES SHALL BE CLEAN AND LEVEL. 6-2 GENERAL FRAMING: F) ALL FINISHED GRADE SHALL SLOPE AT A MINIMUM SLOPE OF 5% AWAY FROM ALL A.) MINIMUM NAILING: MINIMUM NAILING SHALL BE PER 2013 CBC TABLE 2304.9.1. INSIDE DIAMETER FOUNDATIONS A MINIMUM OF 10 FEET HORIZONTAL. WELDED WIRE FABRIC INT G) FOUNDATIONS SHALL NOT BE SCALED FROM PLAN OR DETAIL DRAWINGS. B.) LARGER MEMBERS: ALL FRAMING MEMBERS SPECIFIED IN THESE CALCULATIONS ARE JOIST W/0 WITHOUT MINIMUMS, LARGER MEMBERS MAY BE SUBSTITUTED AT CONTRACTORS OPTION. H) FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND OTHER FOREIGN SUBSTANCES. C. SHRINKAGE: CARE SHALL BE TAKEN TO ALLOW FOR EFFECTS OF SHRINKAGE WHICH COULD 1) USE 4" DIAMETER PERFORATED PIPE SUB -DRAIN BEHIND ALL RETAINING WALLS. SLOPE PIPE CAUSE SETTLEMENT OF ROOF AND OR FLOORS AND COULD LEAD TO FAILURE OF ASSOCIATED TO DRAIN TO DAYLIGHT. FRAMING MEMBERS. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT FRAMING FROM THE EFFECTS OF SHRINKAGE. J.) FOR FOOTINGS PLACED ON OR ADJACENT TO SLOPES, A GEOTECHNICAL ENGINEER MUST D.) ALL STRUCTURAL FRAMING MEMBER WITH EXTERIOR EXPOSURE SHALL BE PRESSURE TREATED APPROVE FOOTING PLACEMENTS IN VIOLATION OF FIGURE 1808.7.1 OF 2013 CBC. THIS OR BE OF MATERIAL THAT IS NATURALLY RESISTANCE TO DECAY. ENGINEER SHALL NOT BE LIABLE FOR ANY FOUNDATION NOT IN STRICT CONFORMANCE TO SECTION 1808 OF THE 2013 CBC. 6-3 BEAM FRAMING: K.) WHERE LOADING TO EXISTING FOUNDATIONS IS NOT SUBSTANTIALLY INCREASED OR MODIFIED, A.) BUILT UP BEAMS: ALL BUILT UP, LAMINATED DOUBLE OR MULTIPLE 2X JOISTS AND BEAMS NO DESIGN RECOMMENDATIONS HAVE BEEN MADE FOR THE SUITABILITY OF THE EXISTING SHALL BE NAILED TOGETHER WITH 16d NAILS AT 6" O.C., T&B U.N.O. FOUNDATIONS. ONLY THOSE FOUNDATIONS WHERE LOADS HAVE BEEN ADDED BY A SECOND STORY HAVE BEEN INCLUDED IN THE DESIGN. THE OWNER SHALL BE ADVISED THAT EXISTING FOUNDATIONS MAY NOT BE STRUCTURALLY ADEQUATE AND SETTLEMENT, CRACKING, AND B.) DOUBLE JOISTS: PROVIDE DOUBLE FLOOR JOISTS UNDER PARTITION WALLS RUNNING PARALLEL OTHER PROBLEMS ASSOCIATED WITH EXISTING FOUNDATIONS ARE BEYOND THE SCOPE OF THIS TO JOIST SPAN AND UNDER ALL LOCATIONS WHERE TUBS MAY BE LOCATED. ADEQUATE DESIGN. IF REVIEW OF THE EXISTING FOUNDATIONS IS REQUIRED, A GEOTECHNICAL ENGINEER SUPPORT SHALL BE PROVIDED FOR ALL OTHER EQUIPMENT OR FURNISHINGS WHICH MAY NOT BE SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING BUT NOT LIMITED TO: HOT SHOULD BE CONTACTED TO DETERMINE THE EXTENT AND ADEQUACY OF THE EXISTING, UN -MODIFIED PORTIONS OF THE FOUNDATIONS. WATER HEATER, STOVE, REFRIGERATOR, OVEN, FIRE PLACE ENCLOSURES, WOOD BURNING STOVE, ETCETERA. 3. CONCRETE /REINFORCING C.) BLOCKING: PROVIDE SOLID BLOCKING IN JOIST FRAMING ABOVE ALL SUPPORTS A) CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 2,500 PSI U.N.O. C) ALL CEMENT USED SHALL CONFORM TO ASTM C-150 AND SHALL BE TYPE II OR TYPE III LOW ALKALI. D) AGGREGATE SHALL CONFORM TO ASTM C-33 AND SHALL NOT CONTAIN MATERIALS WHICH ARE ALKALI REACTIVE AS DETERMINED BY ASTM C-227, 289, AND 295. IF TEST DATA IS UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE CEMENT WITH A MAXIMUM ALKALI CONTENT LESS THAN 0.45% BY WEIGHT. E) CONCRETE EXPOSED TO FREEZING OR THAWING SHALL BE PROTECTED IN ACCORDANCE TO THE LATEST EDITION OF THE ACI 318. F) SLABS ON GRADE SHALL BE PER THE CONTRACTOR. SUMMIT STRUCTURAL DESIGN RECOMMENDS THE FOLLOWING AS A MINIMUM SLAB -ON -GRADE: AT GARAGE SLABS, USE 4" THICK S.O.G. WITH #3 BARS AT 15" O.C. EACH WAY ABOVE MID -DEPTH OF SLAB OVER 2" SAND, OVER MOISTURE BARRIER, OVER 4" AGGREGATE BASE. USE 3-1/2" SLAB WITH #3 AT 15" E.W. ABOVE MID -DEPTH OF SLAB, OR 6X6 WWF ABOVE MID -DEPTH OF SLAB WITH SAME SUB -SLAB BUILDUP AT ALL OTHER AREAS. G) SAW -CUT TOP 3/4" OF SLAB FOR CRACK CONTROL AT INTERVALS NOT TO EXCEED 10'-0" WHERE SLAB IS REINFORCED, SAW CUT AT INTERVALS NOT TO EXCEED 7'-0" WHERE SLAB IS UN -REINFORCED. 6. FRAMING / LUMBER CONTINUED 6-4 POSTS/TRIMMERS: A.) SUPPORT: SUPPORT ALL UPPER LEVEL POSTS AND TRIMMERS IN LOWER LEVELS WITH EQUIVALENT FRAMING AND BLOCK OR OTHERWISE FRAME POSTS THROUGH FLOOR SYSTEMS. B.) WHERE POSTS WITH COLUMN CAPS OR BEARING PLATES ARE SPECIFIED, THE LOAD IS TO BE TRANSFERRED TO THE FOUNDATION BY VERTICAL GRAIN ONLY, U.N.O. 6-5 WALL FRAMING: A.) DOUBLE TOP PLATE SPLICES: SPLICES AND JOINTS IN DOUBLE TOP PLATE OF STUD BEARING WALL SHALL OCCUR AT THE CENTER LINE OF SUPPORTING STUD. TOP PLATE SPLICES OF STUD WALLS SHALL BE 48" LONG WITH (12) 16d SINKERS EACH SIDE OF EACH SPLICE U.N.O. WHERE SPLICE IS INTERRUPTED, USE ST6224 STRAP U.N.O. B.) FIRE BLOCKS: FIRE BLOCK STUD WALLS AT MID -HEIGHT WHERE STUD LENGTH EXCEEDS 10'-0". C.) MIS -PLACED ANCHOR BOLTS: WHERE ANCHOR BOLTS HAVE BEEN INCORRECTLY PLACED, USE SIMPSON SET EPDXY WITH ANCHOR OF SAME DIAMETER WITH 7" EMBEDMENT IN CONCRETE AND INSTALLATION PER MANUFACTURERS RECOMMENDATIONS AND CURRENT ICC REPORT. D.) CRIPPLE WALLS: CRIPPLE WALLS SHALL BE A MINIMUM OF 14" IN HEIGHT. FOR LESSER HEIGHTS, STACK 2X PLATES (AND SHIM AS REQUIRED). E.) NOTCHED OR CUT STUDS: NOTCHED AND/OR CUT STUDS TO CLEAR ANCHOR BOLTS ARE NOT ALLOWED. STUDS SHALL HAVE FULL BEARING TO THE FOUNDATION PLATE. F.) LET -IN BRACES: LET IN BRACES SHALL NOT BE USED FOR TEMPORARY BRACING ON ANY WALL FRAME. STEEL STRAPS WHICH DO NOT REQUIRE THE CUTTING OF STUDS ARE AN ACCEPTABLE ALTERNATIVE. G.) SEE NOTE 6-1 D FOR SILL AND ANCHOR BOLT SPECIFICATIONS. H.) WALL FRAMING RECEIVING NAILING AT 3" ON CENTER OR LESS SHALL BE 3X NOMINAL U.N.O. PER PLANS AND DETAILS. 6-6 CONNECTIONS: A.) HOLES FOR THROUGH BOLTS SHALL BE DRILLED 1/16" OVERSIZE. B.) ALL BOLTS, NUTS, AND LAG SCREWS SHALL BE PROVIDED WITH FLAT OR MALLEABLE WASHERS WHERE BEARING AGAINST WOOD. C.) ALL BOLTS AND LAG SCREWS SHALL BE TIGHTENED UPON INSTALLATION AND RE -TIGHTENED BEFORE CLOSING IN OR AT COMPLETION OF JOB. D.) LAG SCREWS SHALL BE SCREWED, NOT DRIVEN, INTO PLACE. 7. STRUCTURAL STEEL A) STRUCTURAL STEEL: ROLLED STEEL SHAPES, PLATES, AND BARS SHALL CONFORM TO ASTM A-36. WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A-992. B) STRUCTURAL TUBES: STRUCTURAL TUBES SHALL CONFORM TO ASTM A-500 GRADE B. C) ALL WELDING SHALL BE ELECTRIC ARC WELDING, AND SHALL BE PERFORMED ONLY BY EXPERIENCED, QUALIFIED WELDERS. ELECTRODES SHALL BE E60 XX FOR METAL DECK AND E70 XX OTHERWISE, UNLESS SPECIFICALLY NOTED OTHERWISE. WELDING SHALL CONFORM TO AWS D1.1. D) UNSPECIFIED WELDS: WELDS NOT SPECIFIED SHALL BE CONTINUOUS FILLET WELDS. WELD SIZE SHALL BE PER AISC SPECIFICATIONS FOR THE THICKER PART OF THE JOINT. E) ALL STEEL SHALL BE SHOP PAINTED, UNLESS ENCASED IN CONCRETE, GROUTED MASONRY, OR SPRAYED FIREPROOFING, UNLESS SPECIFICALLY NOTED ON THE DRAWINGS. F) BOLTS AND LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O. AND PROVIDED NEW AND WITHOUT EXCESSIVE RUST. 8. ROOF FRAMING 8-1 CUT AND STACKED ROOF FRAMING: A.) CUT AND STACKED ROOF SYSTEMS SHALL BE BUILT TO THE CONVENTIONAL FRAMING REQUIREMENTS OF THE CALIFORNIA BUILDING CODE (CHAPTER 23). PURLINS, BRACES, INTERMEDIATE SUPPORTS, AND CONNECTIONS SHALL BE PROVIDED BY THE CONTRACTOR THAT ARE CAPABLE OF TRANSMITTING ALL GRAVITY AND WIND LOADS TO THE FOUNDATION. B.) IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE THE CONVENTIONALLY FRAMED ROOF SYSTEM WITH TIES AND SUPPORTS BRACING ALL ELEMENTS TO THE FOUNDATION. THE ENGINEER HAS MADE A CURSORY REVIEW OF THE FRAMING SIZES AND SUPPORT LOCATIONS, AND HAS PROVIDED GENERAL CONNECTION DETAILS TO COVER THE MAJORITY OF CONDITIONS, BUT HAS NOT PROVIDED ENGINEERING DETAIL REQUIREMENTS FOR ALL CONNECTIONS NECESSARY FOR THE ROOF TO PERFORM IN ACCORDANCE WITH THE LOADING CRITERIA. IF ANY SPECIFIC ELEMENT OF THE ROOF FRAMING SYSTEM IS NOT SHOWN AND DETAILED CONNECTION CRITERIA IS REQUIRED, PLEASE CONTACT THE ENGINEER FOR ADDITIONAL INFORMATION. 9. DESIGN LOADS A) THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING CRITERIA PER CBC CHAPTER 16, DIVISIONS I, II, III, AND IV U.N.O.: B) SEISMIC: SEISMIC IMPORTANCE FACTOR: 1 MAPPED SPECTAL RESPONSE ACCELERATIONS: Ss = 0.598, S1 = 0.257 SEISMIC SITE CLASS: D SPECTRAL RESPONSE COEFFICIENTS: SDS = 0.527, SD1 = 0.323, Cs = 0.21 SEISMIC DESIGN CATEGORY: D BASIC SEISMIC -FORCE -RESISTING SYSTEM: CANTILEVERED COLUMNS SEISMIC BASE SHEAR: 2.1 KIPS RESPONSE MODIFICATION FACTOR: R = 2.5 ANALYSIS PROCEDURE USED: EQUIVALENT STATIC FORCE PROCEDURE C) WIND: WIND SPEED: 110 MPH WIND EXPOSURE: C D) LIVE LOADS: ROOF 20 PSF REDUCIBLE AB ANCHOR BOLT K KIPS ADD'L ADDITIONAL L ANGLE ADJ ADJACENT LLH LONG LEG HORIZ. ALT ALTERNATE LLV LONG LEG VERT. ARCH ARCHITECTURAL LONG LONGITUDINAL BLDG BUILDING LSL LONG SLOTTED HOLE BLKG BLOCKING LVL LAMINATED VENEER LUMBER BM BEAM MAX MAXIMUM BOTT (B) BOTTOM MB MACHINE BOLTS BTF BEAT TO FIT MECH MECHANICAL BTWN BETWEEN MFR MANUFACTURER CB CARRIAGE BOLTS MIN MINIMUM CCJ CONTROL JOINT MISC. MISCELLANEOUS CIP CAST -IN-PLACE CONCRETE MTL METAL CJ CONSTRUCTION JOINT (N) NEW CLR CLEAR NS NEAR SIDE CMU CONCRETE MASONRY UNITS NSA NELSON STUD ANCHOR COL COLUMN NTS NOT TO SCALE CONC CONCRETE OC ON CENTER CONN CONNECTION OD OUTSIDE DIAMETER CONSTR CONSTRUCTION OH OPPOSITE HAND CONT CONTINUOUS OPNG OPENING CONTR CONTRACTOR OVS OVERSIZE ROUND HOLE CP COMPLETE PENETRATION PDF POWDER DRIVEN FASTENER CTR CENTER PERP PERPENDICULAR CTSK COUNTERSINK PL PLATE DBL DOUBLE PLWD PLYWOOD DF DOUGLAS FIR PLCS PLACES DF -L DOUGLAS FIR - LARCH PP PARTIAL PENETRATION DIA DIAMETER PT PRESSURE TREATED DJ DOUBLE JOIST P/C PRECAST CONCRETE EA EACH P/T POST -TENSIONED EF EACH FACE REINF REINFORCEMENT EL ELEVATION (DATUM) REQ'D REQUIRED ELEV ELEVATION (VIEW) OR ELEVATOR SC SLIP CRITICAL EN EDGE NAILING SEOR STRUCTURAL ENGINEER OF EQ EQUAL RECORD ES EACH SIDE SHTG SHEATHING (E) EXISTING SIM SIMILAR EXP EXPANSION SOG SLAB -ON -GRADE EXT EXTERIOR STD STANDARD EW EACH WAY STIFF STIFFENER FF FINISH FLOOR STL STEEL FIN FINISH SQ SQUARE FJ FLOOR JOIST SS STAINLESS STEEL FLR FLOOR SWS SHEAR WALL SCHEDULE FNDN FOUNDATION SYM SYMMETRICAL FOHC FREE OF HEART CENTER T&B TOP & BOTTOM FOS FACE OF STUD TO(P) TOP OF (PLYWOOD) FS FAR SIDE TOC TOP -OF -CONCRETE FTG FOOTING TOF TOP -OF -FOOTING GA GAUGE TOS TOP -OF -STEEL GALV GALVANIZED TOW TOP -OF -WALL GLB GLUE -LAM BEAM TN TOE NAIL HDG HOT DIPPED GALVANIZED TYP TYPICAL HDR HEADER UNO UNLESS NOTED OTHERWISE HGR HANGER (SIMPSON) VERT VERTICAL HORIZ HORIZONTAL WP WORKPOINT ID INSIDE DIAMETER WWF WELDED WIRE FABRIC INT INTERIOR W/ WITH JST JOIST W/0 WITHOUT JT JOINT K. _y_ a- 0. 75688 E a. 6 0/16 ) ��'OFCAUF��� 5/24/16 TW SE PLANS HAVE BEEN REVIEWED FCR COMPLIANCE ONLY WITH THE ATT/',CHED STRUCTURAL CALCULATIONS , I E J } .::_� r JuU.' 3°3 Rio Lindo Ave. Suite 200 Chico, CA 95925 P. 530.592.4407 i Summi'Chico.com REVISIONS: DATE: 5/24/16 SCALE: NTS DRAWN BY: RKB JOB NUMBER: 15-251 PERMIT # BUTTE COUNTY DEVELOPMENT SERVICES S H ET: REVIEWED FOR C0D; C0 PLlAN DATE � ' L' Q Q �0 • ,-' 0 Q 0- J v0 CD J o _z W LU 1,.,1.,.._ W W OC REVISIONS: DATE: 5/24/16 SCALE: NTS DRAWN BY: RKB JOB NUMBER: 15-251 PERMIT # BUTTE COUNTY DEVELOPMENT SERVICES S H ET: REVIEWED FOR C0D; C0 PLlAN DATE � 1'-0" MAX 2'-0" E.N. FASCIA BY OTHERS---, (3) 16d TOENAILS DBL RAFTER 2X4 FLAT OUTLOOKER AT 24" O.C., NOTCH DBL RAFTER TO SEAT OUTLOOKER TYPICAL GABLE END DETAIL NO SCALE ROOF PLY AND E. N NAILING PER PLAN RAFTER PER PLAN WITH LSU HGR (SLOPED HUC HGR AT DBL RAFTERS) 2X8 DF#2 LEDGER WITH (2) 1/4" DIA. X 4" SDS SCREWS AT EA. STUD, 16" O.C. MAX `ROOF PLY AND NAILING PER PLAN RAFTER PER PLAN RAFTEf EAVE DETAIL NO SCALE L)L.mrvi rL.n rL-r\iv FASCIA BY OTHERS RAFTER NOTE: CORROSION PROTECTION BY OTHERS. 5 TYPICAL HSS POST DETAIL SDI NO SCALE ER PLAN 8' TYP. HSS PER PLAN 1 1/2" CLR HAIRPIN #4 HAIRPIN X BENT AROUND HSS TO HSS, TYP E.S. CONCRETE SLAB—ON—GRADE PER PLAN. SLOPE PER FINISHED GRADE BY ARCH WHERE REQ'D OTHERS, SLOPED AWAY FROM FOUNDATIONS ELEV. PER ARCH 1 1 /2" CLR TYP. . I I I I I (E) WALL FRAMING/4 ROUGHEN A SU ^ -(E) FLOOR FRAMING (E) 1 3/4" LVL RIM E) WALL FRAMING PLATE m 2'-0" DIAMETER PERM!T# BUTTE COUNTY DEVELOPMENT SERVICES NOTE: WATERPROOFING, FLASHING, AND DRAINAGE BY OTHERS. EVIEWED F091 NOTE: NOTE: CORROSION PROTECTION BY OTHERS. CODE 00I'�IPLIAN �_�_.- E3Y tL�a TYPICAL LEDGER DETAIL TYPICAL HSS POST FOUNDATION DETAIL DATE NO SCALE SDI NO SCALE 3 SDI-,, 2 SDIJ Q�Or Ess/o/ f. O < a --No. 75688'' E 6 0/16 CAL�F�� � } THLSE PLANS I-E`*B`�EN _VIEWED FC R COMPLWA �'O'N1LY ITH THE ATTACH ].�T `AL R, \LCkt.JIIA ON i T �'r r 383 Ric Lindo A -e. Suite 200 Chico, CA 95926 P. 530.592.4407 SummilChico.cc-n REVISIONS: � f _a DATE: 8/12/15 -- ----- ---- ---- - - -- SCiILE: NTS C DRAWN BY: RK JC5 NUMBER: 15-251 SH ET: t T / i V J s LLJ U i LU .... _.P` LiJ LUJ J r ....�' (7 .. W _J J LU t t g � I REVISIONS: � f _a DATE: 8/12/15 -- ----- ---- ---- - - -- SCiILE: NTS C DRAWN BY: RK JC5 NUMBER: 15-251 SH ET: