Loading...
HomeMy WebLinkAboutB15-2051rTE,� Butte County Department of. Development Services FORMNO PERMIT CENTER '' ou 7 County Center Drive, Oroville, CA 95965]D13P-66 Main Phone (530) 538-7601 Permit Center Phone (530) 538-6861 Fax (530) 538-2140 - ANTI -ENTRAPMENT CERTIFICATION FORM _FOR SWIMMING POOLS_& SPAS.'., The following form is required whenever a building permit is issued to construct or repair (re plastering) a swimming pool, toddler pool, or spa. . STATEMENT TO BE SIGNED PRIOR TO FINAL APPROVAL - Verification of Compliance with the "Swimming Pool Safety Act of 2006" (Health & Safety Code 115920 115929) Site Address: Property Owner. Phone: Owner's Mailing Address: I hereby certify that the swimming pool, toddler pool, or spa located a the above- mentioned address complies with the.provisions or the "Swimming Pool Safety . . Act of 2006" and has been equipped with.an anti -entrapment cover meeting the current ASME/ANSI Standard A 112.19.8 as required. under the . provisions of the law and have received additional Information on pooh barrier requirements. - .Signed: Date: Owner Signed: Date: 4: Contractor _ CONTRACTOR'S INFORMATION Company Name: California Contractor's License. Number: Mailing Address: Phone: Email: Attachments: Swimming Pool Enclosure Requirements and Pool Barrier handout KMEW WEBSIMBuilding�Building Forms & Documents\ 1pproved 2011 forms -handouts and on listlPool Anti Entrapment Certification Form DBP -66 2011-09.doc Page 1 of 3 Swimming Pool Requirements Drowning Prevention Safety Features Based upon California Health and Safety Code Section 115920-115929, known as the Swimming Pool Safety Act The County of Butte requires either:a listed, approved safety pool cover* meeting ASTM Standard F1346-91, OR a complying enclosure* which isolates the pool from the dwelling and remaining yard, OR a complying enclosure* which surrounds the perimeter of the pool and dwelling, with door alarms and self-closing; self latching'devices on all doors leading into the enclosure. *-Enclosures + Minimum height of 60 inches • Access gates. shall open away from pool and have self -dosing, self -latch Ing 'device no lower than 60 inches above the.ground. . •. Maximum vertical clearance "of 2 inches from the ground to the bottom of endosure • No openings greater than' inch within 18 inches of the release- mechanism when dosed. Gaps or voids shall not allow the passage ofa 4 -inch sphere •.. Outside surface.shall be free of cavities or protrusions that would serve as a foothold or'liandhoi ld that could enable a child of less than 5 years of age: to climb over. Maximum mesh size for chain link shall be a 2.25 inch square unless the'fence is provided.with. slats fastened at the top orbomttowhich reduce the openings to no more'than 1.7¢ inches *Po01 Cover .: Shall be correctly installed per the manufacturer's instructions to prevent the access of children under five years of age. to the water. • Shall be properly constructed to meet ASTM specifications and'be labeled accordingly. • All ties, anchors or attachment. points and controls for automatic covers must be installed In a way to prevent operating or unovering the poll -by children less than five years of age. The pool cover shalt possess a listing that insures the original design or performance of the cover meets. or exceeds testing.as.prescribed by ASTM Standard 171345-91, Section 9 Test Methods for .Safety Covers. Door alarms or self -dosing, seH-latddng doors V*Wms and doors roatinety dosed and latched 'Safety pool cover O Msalation f 'Perimeter .' N • mrd MUnk 0110 Of Mese shaft be provided. +'. s �atchfng (Revised yoe) . K:1NEW_WE13SITE\Building\Building Forms.& Docuinents2014\Word Docs with updated fax no" 2012/Pool_Ant1_Entrapnwnt_Certification—Form—D13 P-66 Rev`d_1.16.13 Page 3 of 3 f�f Swimming Tool Enclosure _Requirements Definitions Approved Safety Pool Cover: A •manual or power -operated safety pool- cover that meets all of the performance standards of the American Society for Testing and Materials (ASTM), in compliance with standard F'1346-91. Enclosure: A fence, wall or combination thereof that isolates, a swimming pool from unauthorized access. Eaeit Alarm: A device -that makes an audible, continuous alarm sound on the doors i -leading from.the dwelling/garage or other structure to the. pool. enclosure, which, when j opened or left ajar, permits entry to the pool. without any intervening enclosure device. .. fl Exit :alarms may be battery operated or connected to the electrical wiring of the building.-. �. Public Swimming. Pool: A swimming pool operated for the use of the general public i with or without charge, or for the use of the members and guests of a private club. Public swimming pool does not:include a. swimming pool located. *on the grounds of a private single family dwelling, i SWimmiag Pool or Pool: Any structure. intended forswimming; recreational bathing or other recreational .use that will contain. .water over. 1:8 :inches in depth. Swimming .pools. include m=ground' and above -ground structures and .include, but are. not- limited to, hot. .tubs, spas, portable spas and non-portable wading pools. Other terms, words, or phrases not defined shall have their ordinarily accepted meanings within the: context: with which they are used. Webster's Third New International Dictionary of the English Language, Unabridged, copyright 1986; shall be considered as. j providing ordinarily accepted meanings. T. h:`NEW_ WEBS ITFIBU'iIding\BIII.IdUlg Forms & Dmllnents\'_011\Word Does With updated fax iio 2012!Pooi_Anti Entrapment_ Certification_Fonn DBP -'6 6 Rev'd 1. 16.13' Page 2 of 3 fl pool engineering v August 17, 2015 2- ©P PERMIT # Mr. Philo Hunt BUTTE COUNTY DEVELOPMENT SERVICES County of Butte REVIEWED FOR 25 County Center Dr. CODEil'L..IANCE Oroville, CA 95965-3500 DATE �' 24 2'� BY �^= Re: Authorization to use Pool Engineering, Inc. Standard Pool'Structural Plan Dear Mr. Hunt: By this notice Pool Engineering, Inc. and the undersigned engineer -of -record shall hereby grant Agua Fina Pools a limited non-exclusive and non -transferable allowance to utilize Pool Engineering, Inc. Standard Pool structural Plan for the permitting and construction of the swimming pool project at the Fearon Residence at 4950 Rich Bar Rd., Chico, CA. Modification or reuse of the construction drawings without the express written permission of the Engineer is prohibited. If we can be of any further assistance, please do not hesitate to contact us. Best regards, ool Eng, Zjodd Lacher,6P.E. This letter is valid only with engineer's signature in red ink Inc. 1201 N. Tustin Avenue, Anaheim, CA 92807 Engineer's Seal a :..' Na.'67656: . Exo..6/30/.1 T rF of ;cA��F° Fax: (714) 630-6114 BUTTE COUNTY AUG 2 0 X iq DEVELOPMENT SERVICE, Phone: (714) 63 0-6 100 NOTE: swimming pool shall comply with ` e Swimming Poo/ Safety Act of 2008 & CA I x30 Zy 0. I(rU� LHeath and Safety Code, Sections 115920- ' A 1115929 01(' Y Complete Anti -Entrapment Certification Form. - d � Provide to building inspector prior to final inspection eAC Y ' I NO CONSTRUCTION IN t EASEMENTS ALL PORTIONS OF STRUCTURE TO BE OUT OF EASEMENT -INCLUDING FOOTINGS, FOUNDATIONS, WALLS, EAVES AND ROOF ti ~ I 1 `1 f r MJINIGM 3 _�-- ' Y+kiyn, - Separate Mechanical Permit require d�for tFie'installation of a swimming pool heaterMW I r Comply with 2013 California Energy commission requirements for ! swimming pools 2013residentia/ r f ;,,; Mo,.,,.,F r ,��...• lomp/lance Manua/ section 5.2. `` z ed;,t CL Z • u POOL EQUIPMENT' SHALL BE i r `,`_'INSTALLED ADJACENT TO •'-JTHE HOUSE AND AT SAME ` ;!:ELEVATION `� r- ��• OR HIGHER. _ J 9 {1 13 NOTE: See S'the attached d .. 1 Swimming Pool Requirements r LU Cc LAJ CM C" = Liz CAI C! LU 1J, lLAJp Cj Lb — 1 RMIT # ���° 2 �.�� Lil WCJ_ BU I I t U(OU,NTY DEVELOPMENT SERVI s E— Illll ' REVI EWTOF E I /p;... F )co EISI PLI N E !I: ATE y4ls'BY 9 DRAWN BY. �\\ I -� r;•`I '' J„ ..� L.G. _ S.M. - - . DT TT_Tn , {� DATE: _CEC 680.26C.EQUIPQTENnAL BONDING GRID COMPLY WITH 2013 CALIFORNIA SHALL BE INSTALLED AS DESCRIBED BY THIS CODE-THE?/16/15 E LE/�Tp*CAL" EQUIPOTENTIAL BONDING GRID SHALL EXTEND UNDER PAVED V rU WALKING SURFACES 3FT HORIZONTALLY BEYOND THE INSIDE = CODE ARTICLE 680 WALLS OF THE POOL: REVISION -CEC 680.26 r w - EQUIPOTENTIAL BOND BONDED PARTS r 680.26(B)(1) THROUGH (7).$HALL BE BONDED N TOGETHER BONDING SITE PLA - 1 — I� �Cuv'�iTtL'rM1?fSiJ'?m�.uci--�'� F• i