Loading...
HomeMy WebLinkAboutB15-2136Array: 4 Modules: (66) SolarWorld SW285 Mono 285W Modules Inverters: (66) Enphase Energy M250 240W AC Microinverters Mounting Method: Flush Mounted. - (66) modules _ Ironridge roof mount system with XR100 rail Array Azimuth: (66) Modules at 180°_ PV System Equipment Wall (Plin"View) Equipment Wall ,Pqment Wall Array (Adjacent to utility meter) hop) '(on RooA B C D E F G H A: (Existing) Ap-in -one utility meter and main service panel, 200A, 120/208V, 30 G. B: (1) (New) Wire Runs C: (1) (New) PV system dedicated 30A AC Disconnect Switch (fused) (Visible, Lockable, Labeled) (Adjacent to main service panel) D: (New) 30 KVA 48OV: 120/208V Transformer E: (1) (New) PVC SCH. 40 conduit run 175. ft run) (Buried 18" below grade) ' F: (New) PV system dedicated 125A, AC aggregate panel G: (1) Wire runs H: (3) (New) PV sysiem junction box (UL 1741, NEMA 3R) (Located behind modules) OWNER / JOBSITE Anderson Family Orchards - 5498 Ord Ferry Rd., Chico, CA 95928 `a APN: 039-050-005 ' CONTRACTOR + _ North- State Solar Energy PO 'Box 899 E Forest Ranch, CA 95942 r A, B, C, D Lic. #813508 t E PROJECT DETAILS New 18KW solar PV roof 1, mount array using t microinverters on Ridge, .Iron racking system tied into ?Ya existing load center. All wiring is AC. t .,.., P F (66) 208 WATT Utility Interactive Inverters - Fdge it Enphase M250-60-208-522 ,- CEC Model: Enphase M250-60-2LL-S2x (-ZC)(7NA)(208V) Page Details: CEC-Inverter Efficiency: 96.5% Single Line Diagram for 208VAC, 3�, 60Hz L Anderson Family Farms Voltage and Phase Sensing Neutral y Listed to UL 1741 ` 48 VDC Max Input Voltage Integrated G.E.C. Ground Project Details: ' New 18KW Roof Mount PV PV Circut: s (22) SolarWorld'SW285 Mono Module Module Moduli Array using microinverters on 285W Modulen Box .Iron Ridge mounting system - NEcMA tion 3R� UL 1741 Microimertzr Microinverter Microinverter going to existing load. center. (At Array) PV Circut: (22) SolarWorld SW285 Mono Module Module Module 285W Modules Main Service Line Side 1' Microinvzrter Microinverter Microinverter PV Connection l: t Via NSI Polaris Lugs ' 240 VAC (f20 FT RUN) Allowed Per CEC 240.21 (D), PV Circut: 6 - #12 AWG THWN-2 CU 705.12 (A), and 230.82 (6) (22)-SolarWorld SW285 Mono Module Module Module 1 - #12 AWG THWN-2 CU (N) 285W Modules E 1 - #8 AWG THWN-2 CU E.G.C. f� (Gnd to be continuous) Microinverter Microinverter Microinverter 1" LFMC Conduit (Run behind array) (Existing) Utility Meter (New) Dedicated PV System Utility AC Disconnect Switch (±175' ft run) 240 VAC 30A, NEMA 3R • 3 J- #3 THHN CU Enphase AC (3) 30A Fuses 1 �- #3 THHN CITNeutral Engage Cagle t o (Visible Blade Type, Lockable, l And Bare #6 AWG ,; #6 THHN CU E.G.C. E.G.C. Ground + Labeled, Accessible 24/7) (Giid to be continuous) • 1.25" PVC SCH 40 Conduit (Buried 18" below grade) ; w 200A is t: 60A 3-P 1, 1` 20A 3—P i F s 20A 3-P t 20A 3-P Dedicated PV System 480V 120/208V AC Agregate Panel ' 120/208 VAC, 125A, NEMA 3R PV System Transformer Main Lug Onlyl 30 KVA, NEMA 3R (3) 3P -20A PV Circut Breakers ' 3 - #8 THHN CU Adjustable Voltage Taps (Located at Array) 1 - #8 THHN CU Neutral Primary: 120/208V 1 - #8 THHN CU E.G.C. i Secondary: 480 DELTA (Gnd to be continuous) 1" LFMC conduit - (Run along equipment wall)