Butte County Department of Development Services
BUILDING DIVISION
7 County Center Drive, Oroville, CA 95965
Main Phone 530.538.7601 Permit Center Phone 530.538.6861 Fax 530.538.7785
t��v w. buttecouizti,.net;�ad
SPACIAL INSPECTION NOTA
/ .
For Building Permit # B j �� - 2l yL ,Assessor's Parcel # � .3� � Z V,V
- ��
Structural Tests &Special Inspections- 2013
to the inspections required by Division II,
Professional acting as the owner's agent shall
provide inspections during construction on t
California Building Code Chapter 17: In addition
Section 1101) the owner or Registered Design
employ one or more special inspectors who. shall
he types of work listed under. section 1704. The
speciai inspector snau ue a quaiiriea person who shall demonstrate
competence, to the
satisraction of trie building othcial, dor inspection of the particular type of construction or
operation requiring special inspection.
Duties and Responsibilities of the Special I
1. The special inspector shall observe the work assigned for conformance with the approved design,
drawings and specifications.
2. The special inspector shall furnish inspection reports to the building official and the engineer or
architect of record. All discrepancies shall be brought to the immediate attention of the contractor for
correction, then, if uncorrected, to the proper design authority and to the building official.
I The special inspector shall submit a final signed report to the Butte County Building Division stating
whether the work requiring special inspection was, to the best of his or her knowledge, in conformance
with the approved plans and specifications and the applicable provisions of this code.
4. The special inspector shall advise the contractor that Butte County Building Division inspections
cannot be delegated to him or her, so inspections must also be made by the Butte County Building
Division.
5. Any change in special inspection firms made after permit issuance shall be approved by the Butte
County Building Division prior to the new firm performing any inspections.
6. Special inspections are in addition to the regular inspections performed by the Butte County. Building
Division. Butte County inspection approval and sign off is not to be construed as authorization to
proceed with work which obscures, covers or otherwise prevents proper special inspection.
Special Inspection is required for the following items:
D Reinforced Concrete (Taking of test specimens, placement of reinforcing and placing of concrete).
❑ Structural Masonry
1%, High Strength Bolting ..
1:1 Welding
❑ Bolts Installed in Concrete
El Other:
*Name of Special Inspection Company:
*PENDING APPROVAL. SPECIAL INSPECTION COMPANY SHALL PROVIDE A STATEMENT
OF QUALIFICATIONS AND COPIES OF CURRENTSPECIAL INSPECTOR CERTIFICATIONS
FOR APPROVAL BY THE BUILDING DIVISION PRIOR TO 0
�JT
W
'rt
n
�v
,C3
5rr
Hardwood plywood veneer core
0.05
0
Hardwood plywood composite core
0.08
Particleboard
Medium density fiberboard
0.09
0.11
u�
0.21
v � r
5'r �
a � �
8
I r
9
ca
-I
Butte County Building Department
California Green Building Standards Code
Residential VOC Checklist
VOC COMPLIANCE CERTIFICATION
ADHESIVE (NONE O) 1 MANUFACTURER CALGreen LIM 11-1 ACTUAL VOCs
SEALANT (NONE O) 1 MANUFACTURER CALGreen ACTUAL VOCs
ARCHITECTURAL COATINGS (NONE O) MANUFACTURER CALGreen ACTUAL VOCs
FORMALDEHYDE COMPLIANCE CERTIFICATION
PRODUCT (NONE O)
MANUFACTURER
CURRENT LIMIT
ACTUAL
Hardwood plywood veneer core
0.05
Hardwood plywood composite core
0.08
Particleboard
Medium density fiberboard
0.09
0.11
Thin medium density fter onrd
0.21
All Carpet installed in the building interior meets the testing and product requirements of the following (check one)
n Carpet and Rug Institute's Green Label .
O California Department of Public Health Standard Practice for the testing of VOCs
n NSF/ANS1140 at the Gold Level
O Scientific Certifications Systems Indoor AdvantageTm Gold
O No carpet installed on this project
certify that the information provided on this form is accurate and that the materials used on this project
comply with Section 4.504 (Residential) or 5.504 (Non -Residential) of the 2010 California Green Building
Standards Code.
Print name Signature Date
' See other side of page for VOC limits
I
1
Butte County Department of Development Services
TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR
7 County Center Drive
Uroviile, CA 95965
(530) 538.7601 'telephone
(530) 638-2140 Facsimile
)mw,vbuftecountv,MeVdds
www.butteneneratplan.net
ADMINISTRATION * BUILDING'S PLANNING
r�
MINIMUM EROSI-ON'AND SEDIM-ENT CONTROLS FOR
PROJECTS DISTU"RBING LESS THAN ONE ACRE
The BR9p's (gest Management practices) listed below must be in place during the rainy season
(October '!5 through April 76) and may be required at other dimes based on weather and site
.
conditions throughout the year. The BMP's listed are minimum requirements and additional BMP's
could be required based on site conditions.
• Stabilized entry: Provide minimum 3" to.6" fractured rock 50' tong x 15' wide by 6" deep over
construction. grade fabric. .
All soils tracked onto paved roadways gust be* cleaned up on a daily basis. When streets are wet or
during a rain event there shall be no tracking of soils onto*the street,
Waffles installed propedy. behind c orsidewalks.
Rook bags (mlnftutn.2 per side) at all
drain inlet locations within 150" of the P ro1'ect site.
e - Intetnal fid placed inside each drain Inlet.
e Trash bars ecross the back of all drain inlets.
d Stabilize all disturbed soils In the front yard areas within 15' of the back of curb or sidewalk. (Straw
or erosion blankets may be used fol- this applicaflon)
Stabilize all slopes where erosion could occur and cause sift run off. (Straw, visqueen or erosion
blankets- may be used for this applicatfon)
All paint, fuel, constnxAlon products etc. shall be stoned in a covered location away from sidewalks
and storm drairr inlets.
e Portable chemical tollets if provided on the site must be kept off of streets and sldewalks and at least
54' from the nearest storm drain inlet.
e All trash must be collected and stored properfy. Do not let items such as drywall mud boxes, paint
.
buckets, cleaning material contalners etc. come in contact with any rainfall or storm water runoff.
• Provide a designated area for concrete washout. Hay bales lined with visqueen may be used for this
application. rollaway bins may also be used. All concrete washout systems shall be placed off of
the paved streets.
• After installation of the above Iters Is complete a nriaintenance program needs to be developed to
Insure the continued effectiveness of your BMP`s.
K:IBLIILDING120I 11A,pproved formslRes Green Bldg. formslErosion &Sediment Control Measures.dvc
J%
I t
n
1
0
R,
GENERAL NOTES
I. THE GONTRAGTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND 51TE CONDITIONS
BEFORE STARTING WORK. THE ENGINEER SHALL BE NOTIFIED IN WRITING OF ANY
D I SGREPANG I ES.
2. THE CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY
FOR JOB 517E CONDITIONS DURING THE GO'JRSE OF THE PROJECT, INCLUDING SAFETY OF ALL
PERSONS AND PROPERTY; THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING H0UR5; AND THAT THE CONTRACTOR SHALL DEFENLD,INDEMNIFY
AND HOLD DANIEL J. DOBBIE HARMLE55 FROM ANY AND ALL LIABILITY,
REAL OR ALLEGED, EXCEPT FOR LIABILITY ARISING FROM THE 50LE NEGLIGENCE OF
DANIEL J. DO55IE.
B. THE CONTRACTOR AGREES THAT HE/SHE SHALL NOT DEVIATE FROM THESE DRAWINGS
WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE ENGINEER.
4. ALL OMISSIONS AND/OR CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE WORKING
DRAWIN65 AND SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE
ENGINEER.
5. IF CERTAIN FEATURES OF CONSTRUCTION ARE NOT FULLY SHOWN ON THE DRAWIN65 OR
GALLED OUT IN THE NOTES OR SPECIFICATIONS, THEN THEIR CONSTRUCTION SHALL BE THE
SAME AS FOR SIMILAR CONDITIONS WHICH ARE SHOWN OR GALLED OUT ON THE DRAWIN65
OR SPECIFICATIONS OR AS DIRECTED BY THE ENGINEER.
6. ALL CONSTRUCTION, INCLUDING MATERIALS AND WORKMANSHIP, SHALL CONFORM TO THE
INTERNATIONAL BUILDING CODE 2012 EDITION AS ADOPTED AND MODIFIED BY THE STATE
OF CALIFORNIA IN REFERENCE TO THE 2013 CALIFORNIA BUILDING CODE (GBG).
7. IN AREAS OF EXCAVATION THE CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL
EX1571N6 UNDERGROUND UTILITIES BEFORE STARING EXCAVATION.
8. THE CONTRACTOR SHALL NOT SCALE THE WORKING DRAWINGS.
F-i"v
A ,1--Z , ,
I {
_x
SPECIAL INSPECTION
I. SPECIAL INSPECTION IS REQUIRED FOR THE FOLLOWING TYPES OF WORK IN CONFORMANCE
WITH SECTION 1-704 OF THE 2013 EDITION OF THE "CALIFORNIA BUILDING CODE" (GBG):
INSTALLATION OF HIGH STRENGTH BOLTS BOLTS IN CONCRETE
FOR SPECIAL IN P TI N:
N R M NT A MET EG 5 EG O
2. THE FOLLOWII 6 EQJIRE E SHALL BE O 5
A. THE SPECIAL INSPECTOR SHALL BE UNDER THE 5UPERV1510N OF A RE6ISTERED
PROFESSIONAL ENGINEER.
B. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE
WITH THE APPROVED DF -516N DRAWIN65 AND SPEC IFICATION5.
G. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING
OFFICIAL, THE ENGINEER, THE ARCHITECT, AND OTHER DESIGNATED PERSONS. ALL
DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR
FOR CORRECTION; THEN, IF UNCORRECTED, TO THE PROPER DES16N AUTHORITY AND THE
BUILDING OFFICIAL.
D. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT SIGNED BY THE RE615TERED
PROFESSIONAL STATING WHETHER THE WORK REQUIR►N6 SPECIAL INSPECTION WAS IN
CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE
WORKMANSHIP PROVISIONS OF THE C.B.C.
3. SPECIAL INSPECTION APPLICATIONS MUST BE REVIEWED AND APPROVED BY THE BUILDING
DIV1510N PRIOR TO THE ISSUANCE OF A PERMIT. ALL INSPECTION REPORTS SHALL NOTE ANY
DISCREPANCIES AND BE FILED WITH THE BUILDING DIVISIION WEEKLY DURING CONSTRUCTION,
WHETHER CORRECTED OR NOT. INSPECTOR SHALL MAINTAIN INSPECTION L065 AT THE JOB
51TE FOR REVIEW BY THE BUILDING OFFICIAL OR H15 REPRESENTATIVE.
4. INSPECTION PR06RAM:
a.) SPECIAL INSPECTION OF THE H16H STRENGTH BOLTS SHALL OCCUR DURING BOLT INSTALLATION
AT THE ERECTION OF THE STEEL FRAMING.
b.) SPECIAL INSPECTION OF THE BOLTS IN CONCRETE SHALL OCCUR PRIOR TO POURING CONCRETE
AFTER BOLTS ARE TIED IN PLACE.
c.) SPECIAL INSPECTION OF CONCRETE AT TILT -UP PANELS SHALL BE PER 2013 GBG TABLE 1'105.3
FOUNDATION
I. 501L DE516N INFORMATION:
501L DESIGN PRESSURE:
PAD FOCTIN65 1500 P5F
2. BOTTOM OF FOOTINGS SHALL BE AT LEAST 12 INCHES BELOW LOWEST ADJACENT FINISH GRADE.
3. THE FINISH EXCAVATION FOR FOUNDATIONS SHALL BE NEAT $ TRUE TO LINE WITH ALL LOOSE
MATERIAL AND STANDING WATER REMOVED BEFOREONCRETE 15 PLACED.
4. THE TE5TIN6 LAB SHALL SUBMIT COMPACTION REPORTS FOR ALL FILL TOTHE ENGINEER
PRIOR TO REQUESTING FOUNDATION INSPECTION. ALL LOOSE 501L AND FILL DIRT, INGLUDIN6
BACKFILL BEHIND RETAININ6WALLS, SHALL BECOMPACTED TO AT LEAST c1090 OF MAXIM M DENSITY
REINFORCING STEEL
I. BAR REINFORCING SHALL CONFORM TO ASTM A615, INGLUDIN6 SUPPLEMENT
51: ALL REINFORCING SHALL BE GRADE 60.
2. DETAILS FOR REINFORCING SHALL CONFORM WITH CHAPTER 7 GF THE
AMERICAN CONCRETE INSTITUTE PUBLICATION 318-10,. UNLESS OTHERWISE
NOTED.
3. LAPS AT BAR SPLICES IN CONCRETE CONSTRUCTION SHALL
CONFORM TO CHAPTER 12 OF THE LATEST EDITION OF THE AMERICAN
CONCRETE INSTITUTE 315.
4. VERTICAL BARS IN CONCRETE CONSTRUCTION SHALL BE ACCURATELY
POSITIONED AT THE CENTER OF THE WALL, UNLESS OTHERWI5E NOTED.
5. BAR SUPPORTS SHALL BE PROVIDED AS SPECIFIED IN THE "MANUAL OF
STANDARD PRACTICE" ISSUED BY THE CONCRETE REINFORCING STEEL
INSTITUTE.
6. ALL REIFORGING SHALL SECURELY TIED IN PLACE PRIOR TO PLACING
CONCRETE OR GROUT.
7. WELDING OF 0RO55!N6 BARS AND TACK WELDING OF REINFORCING SHALL NOT
BE PERMITTED_
I I I I I
I
I
'I II
I
I I
i � I
I I I I
I I I
I I I
I I
i I I
i it I I
I
I I I I I
I II I
I I
I
t' i I II
I I
I II
I
i I
i
I'i I
I I.
i
I. I
I I li I I I I
I I I
I I I
I I
I I I I I I I
I I
I I l
I I I I I I II
I I�!' i•. 'I li I
I I I I li I I I I
I I I I I
I !
I I I
! I
'1
I, I�
I I I!
I i I
I !
I
II i I� I
I II I!
I I
I I
I� I
I
I I
I I I
I
i I I I
I I I I
I i' I I it li I
I ! ! 1
I' (
I
1 I I I
I' I
I, II
I
I I II I
I
I I I
I�
i
I I II
I'
I I I
r I
I I i L
i I
I I I I
I I
I I'
I
I I
I I it
I I
I I I
I I I i
I i
I I
I I
I I�
I � I
I I I
I I i I i I
I
I
I I.
I I I I I
i �i II
I I I i
I
I I i
I
I I I i
I I I II
I I i
I I I
I i I I I
I I I I
II I
I I I
I I'
I I iI !• I' I I I I .I i I' I.
I I I I
u i I I I
I I I I
I I I it
I I I I ii I ii , I I II
NOR H ELEVATION
I I,
I III I II I� I
I I
Ld
�-
W III I I! III II ,I III Ii ! III I', II
-
!' I III I II II I III
QUI' ;I'Ij I i Il,lillll:li!' ,'ll'
W = II II ! II li 'I II II II Ii I!
I I. i'. I I I II I Ii 'I iii I I. I� I I II II I I
I'
WEST ELEVATION
3/32" = 1'-0"
3/32" = L' -O"
4,
EAST ELEVATION
y
METAL SIDING
MPTAI f2nnFlNe-
501J`H ELEVATION
3/32 = 1'-0"
REINFORCED CONCRETE
I. A. THE MINIMUM 28 DAY CONCRETE 00MPRE551VE STRENGTH SMALL BE:
FOUNDATIONSd CURBS 3000 P51
NO SPECIAL INSPECTION OF CONCRETE 15 REQUIRED AS NOTED BELOW
PER 2013 GBG SECTION 1-705.3 EXCEPTION I. 150LATE-D FOOTIN65 < 3 STORIES
THEREFORE NO SPECIAL INSPECTION OF. CONCRETE SHALL BE REQUIRED.
B. THE MAXI LUMP SHALL BE 4 INCHES.
G. MIX DE516NS SHALL BE SUBMITTED FOR ALL CONCRETE WITH REQUIRED
STRENGTHS GREATER THAN 3000 PSI. MIX DESIGNS SHALL BE PREPARED BY A
PROFESSIONAL ENGINEER RE615TERED IN THE STATE OF CALIFORNIA AND
SUBMITTED TO THE PROJECT DE516N PROFE551ONAL FOR REVIEW.
2. PORTLAND GEMENT SHALL CONFORM TO ASTM 6150, TYPE I OR 11.
3. AGGREGATES FOR NORMAL WE16HT CONCRETE SHALL CONFORM TO ASTM 633.
4. ADMIXTURES USED TO INCREASE THE WORKABILITY OF THE CONCRETE SHALL
NOT BE CONSIDERED TO REDUCE THE SPECIFIED MINIMUM GEMENT CONTENT,
5. READY -MIX CONCRETE SHALL BE MIXED AND DELIVERED IN ACCORDANCE WITH
A5TM GQ4.
6. MINIMUM CONCRETE COVER (IN INCHES) FOR REINFORGIN6 STEEL FOR NON -
PRESTRESSED CONCRETE;
A. GA57 AGAINST AND PERMANENTLY EXPOSED TO EARTH 3"
B. FORMED SURFACES EXPOSED TO EARTH OR WEATHER
. #6 AND LAR6ER 2"
#5 AND SMALLER 1 1/2"
�. SLEEVES, PIPES, AND CONDUITS SHALL NOT BE PLACED THROUGH CONTIN'UO'US OR
SPREAD FOOTINGS, GRADE BEAMS, OR TIE BEAMS.
8. CONSTRUCTION JOINTS SHALL BE ADEQUATELY KEYED. THEIR LOCATIONS AND
DETAILS, WHEN NOT SHOWN ON THE DRAWINGS, SHALL BE SUBJECT TO THE
APPROVAL OF THE ENGINEER.
q. CONCRETE PLACEMENTS SHALL BE CONTINUOUS BETWEEN CONSTRUCTION JOINTS.
10. UNLESS OTHERWISE 5HC^N ON THE DRAWIN65, 5LABS ON GRADE SHALL BE
CAST IN SQUARE OR RECTANGULAR PATTERNS NOT EXCEEDING 400 50UARE FEET,
WITH A MAXIIMJM PIMEN51ON OF 20 FEET BETWEEN CONSTRUCTION, WEAKENED
PLANE, OR CONSTRUCTION JOINTS.
NOTE: -
Property owner is responsible for determining
locations of property lines and easements and
maintaining required setbacks from property lines and
easements. A survey may be required if determined
Y
I t
necessary by the building official f
00
I
PROPOSED NEW
TRACTOR STORAGE
I
BUI �, LD(HATCHED)i
G
i
�i
i 6
O,
ti
r
Flood Zone;( TANK
o F.I.R.M.: 06002 C 0sW_
O
N
(f1 I (E) BILDIN65 I
I
.J
NO CONSTRUCTION IN i-) RE5!DENCE (E) SEPTIC
EASEMENTS - 1
-ME TAL 511;)IN6 ALL PORTIONS OF STRUCTURE TO BE OUT
AT 5KIR71IN6 OF EASEMENT -INCLUDING FOOTINGS,
FOUNDATIONS, WALLS, EAVES AND ROOF 1
I (E) LEACH
OPERMIT WILL BE RQUIRED FROM
iv BUTTE COUNTY BUILDING DEPT.
FOR FUTURE ELECTRICAL - -
INSTALLLATIONS 517c PLAN
APN 0--15-240-OQI
SHOP BUILDING:
BUILDING GODS ANALYSIS:
See attached- Minimum erosion control and
sediment controls for projects disturbing less CALIFORNIA BUILDING CGDE 20-73 EDITION
than one acre OCCUPANCY GROUPS:
AGRICULTURAL BUILDING U
APPENDIX C O
0
TYPE OF CONSTRUCTION II -B r ry0
ALLOWABLE AREAS: m
CBC SECTION 1704 SECTION 6102.2 ONE-STORY UNLIMITED AREA
SPECIAL INSPECTION REQUIRED THE AREA OF ANY ONE-STORY GROUP U AGRICULTURAL
BUILDING SHALL NOT BE LIMITED IF THE BUILDING 15
i
ee attached Specral Inspection SURROUNDED AND ADJOINED BY PUBLIC WAYS OR YARDS BUTTE
Note NOT LESS THAN 60 FEET IN WIDTH. COUNTY
-- - - - ALLOWABLE BUILDING AREA MI7ED
Future occupancy changes will be L11 EP
APPROVED PLANS AND PERMIT 0 120'
required to meet the regulations ACTUAL BUILDING AREA 6,OCO SF OK_
SHALL BE ON SITE FOR ALL required at the time of permit FIRE PROTECTION ANALYSIS BURDICK ROAD p�VELOPIKET
SE
INSPECTIONS application for a new occupancy
change or tenant improvement
BUILDING PERMIT# Z
ASSESSOR'S PARCEL# - l
PERM, i w
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED FOR
CODE COMPLIANCE
DATE BY a1v
� � �f riv v -e^1r %qy e�
RVICES
TABLE 601-ZI NC
TYPE II -E3 REQUIRES O FIRE -RESISTANCE RATING AT ALL BUILDING ELEMENTS.
TABLE 602
A MINIMUM FIRE SEPARATION DISTANCE OF 30'-O" SHALL BE OQROFESgj��
MAINTAINED AROJND THE PERIMETER OF THE BUILDING.
J. p0 '9l
OCCUPANT LOAD: (5EG 1004.1)
m
OGGUPANT/AREA LOAD FACTOR FOR AGRICULTURAL 15 300 0. 42028
EV. 03/31/16
6,000 / 300 = OGCUPAN7 LOAD = 20 OGGIJ-ANT51
HEIGHT LIMITS: - - --. - - 9�FpF AIt1F0���
SECTION 6102 BUILDING HEIGHT v -
TABLE C102.1 ALLOWABLE 5UILD!N6 HE16H7 55 FEET
>70R TYPE II -B GONSTRUGTiON _¢- AUG 1.9 WS
MAXIMUM B'UILDIN6 HEIGHT AS PROPOSED: --,
I
i
FILE COPY
REVISIONS I BY
01
W CO)
m
Q
mQQ p�3a
C>wc:4UJ 0
XW•�
U-1 �LnC C
8!
00- LL°-
s�,r
R,
:'fes
U
e� U^a
U
O�
z0
.i m
U
0
an' a:US
(D M
8/18/2015
SCALE
Iqc L/11
DRAWN VV
did
.a6
15033
SHEET
0
1501-01,
I I �
FOOT I NG5 I2 O 12 O '2 O 12 l O d P �DESTALS
d PEDESTALS
I I I I m IV
iI I i, I I I I I I =
----} - - --- - -=71- -- - - - - - -- ----- - -- - - -- - - - - - ------ - - ------- -I------ }
IJ J I I � I I --t— I I I �—I L J
LREFERENCE_J LINE
i L__J L__J L__J Al LINES 2-5
i
CURB , I CURB `p
AUS P(X3�1 NLa� [�Y.1�GlkFS � IkO�i,(� � j
71�� C -UF aN AND k7h V-6 PYK P�Tl I —
r _ B
III ( I
-WE DP ' WECT I O N, I I 2
IB \Z I I III
�O J 2 L — _ J NO FLOOR SLAB I Future occupancy changes will be m L _ _ J
required to meet the regulations
w required at the time of permit w
0 application for a new occupancy I p
�
I ( change or tenant improvement
a I i-- 10
Oz �� ' T7 Oz
o� r7.1 = r --I r_! r --1 REFERENCEINo�
I I I I I I I LINES 2-5 S Q
II I I ►�, I I I I I I = II =
12 L_—J L_I_J L_ J L_1_J
lO 12 lO I 12 I 12 lO 12 IMAGINARY r
e BUILDIING LINE G
PERMIT WILL BE RQUIRED FROM 1
BUTTE COUNTY BUILDING DEPT. INDICATES INDICATES
' PEDESTAL TYPE � FOOTING TYPE �
FOR FUTURE ELECTRICAL — —
INSTALLLATIONS COMELY WITH CALIFORNIA
ELECTRICAL CODE- ARTICLE 250
FOUNDATION PLAN
-`1 REQUIREMENTS FOR GROUNDING
and BONDINGFOR EXACT LOCATION OF ANCHOR BOLTS SEE VARGO PRUDEN ANCHOR ROD PLAN,
A
x WIDTH B
FOOTING SCHEDULE:
3512" ® IB
® IA MIN. EDGE DISTANCE
f
t 4 - 3/4"b F1554 (GRD 36) THREADED RODS
'
ivv-314' WA5HERS AT BOTTOM
NOTE: TOP OF PEDESTAL SHALL
BE LEVEL WITH ALL OTHER
-REFERENCE L NEPEDESTALS d CURBS
PER PLAN
D PE
DESTAL NOTE::
PEDESTALS SHALL
X BE POURED MONOLITHICALLY
/ Q WITIH FOOTINGS, NO GOLD
/ JOINTS SHALL BE PERMITTED.
SEE PEDESTAL PLANS
1-#3 TIE I" BELOW
TOP OF FOOTING
TYP
#5 ® I5"0,.c.TRAN5 U.O.N.
TOP d BOTTOM
Q EXCEPT AT ID
m BOTTOM LONGITUDINAL
REINFORCING PER SCHEDULE
1pre-S
-KV
ul
TYPE �@ PEDESTAL PLAN
TYPE A B G D REIN'".
IA 10'-0" 5'-0" 2'-O" 4'-6" 4 -#5 i
IB „ 5 -#5 EA. WAY 4 - #5 VERT. N ( 3/4" CHAMFER
6'-4" 6'-4" 2'-O' 3'-2 TOP d BOTTOM REINF. DOWELS NP
O
4'_O" 4'-O" 2'-O" W 4 -#5 EA. AY 4- %" F1554 A.D.
I G I '-b" TOP d BOTTOM /
LOCATION PER i CONCRETE
VP ANCHOR PLAN c PEDESTAL _
O I o -,
#3 TIES ®6 o.c. '
AROUND PEDESTAL to
VERT. REINF. -
SEE 3-#3 TIES
WITHIN TOP 6" -- SIJILDING LINE
AT DETAIL I
TYPEfO PEDESTAL PLAN
!
I
-0 0
2- !/a" F1554 A.B.
LOCATION PER
VP PLAN ,
FOR ITEMS NOT
NOTED SEE TYPE I
PEDESTAL PLAN - 4— -
TYPE ID PEDESTAL PLAN
11
0
-—CE3
0
FOR ITEMS NOT
NOTED SEE TYPE
PEDESTAL PLAN
o _
2- 5/a" F1554 A.B: o
LOCATION PER
VP PLAN
TOP OF PEDESTALS SHALL
G
/ I MATCH TOP OF CURES
TYPE III PEDESTAL PLAN
i
_ 8/2" GONG.
MS NOT CURB
SEE TYPE I
AL PLAN
of
2- 3/a" F1554 A.B.
LOCATION PER =
VP PLAN
LLJ
BUILDING LINE
TYPE II PEDESTAL PLAN
PERMIT # +'✓� -
BUTTE COUNT
Q�pFESS/pN
J. DD�q��
co
w No.42028 m
* Exp. 03/31/16
'SERVICES `P�q/ CNIL ���P
REVIEWED FOR 4z OF
CO COMPLIANCE AUG z 2015
DATE � 1 - - - - -- C�Z-
REVISIONS I BY
O�
W a } N
�a m
�
mZ83Q
.2 F,U-j
p X W
.J 0 m i.+ 0 .'.i
z
._ . a 0, = O
*o 0 0 1-
.r` d
Uf Q
- °^
x U
z�pco
c� a U
b
8/18/2015
SCALE
UON
DRAWN
djd
JOB
15033
SHEET
OF SHEETS
3-#3 TIES WITHIN
TOP 6" OF PEDESTAL
TIES I" APART
_DING - --- _I
70°7 OF CUR -55 SHALL
AROUND COLUMN
=
MATCW TOP OF PEDESTALS
VERT. REINF.
N"
PER
2-4 CONT.
BUILDING LINE i
AT TOP
3/4" CHAMFER TYP
CURB BEYOND PER
2/2 WHERE OCCURS
a�/:2" CON'. STEM
#5 a 18 o.c. EACH WAY
Q
WALL W/ #4
TYP AT TOP REINF. U.O.N. !
15"o.c. VERT.
tv
v
�
—
z
1- #4 CONT.
—
-
(V
V
�=
A
x WIDTH B
FOOTING SCHEDULE:
3512" ® IB
® IA MIN. EDGE DISTANCE
f
t 4 - 3/4"b F1554 (GRD 36) THREADED RODS
'
ivv-314' WA5HERS AT BOTTOM
NOTE: TOP OF PEDESTAL SHALL
BE LEVEL WITH ALL OTHER
-REFERENCE L NEPEDESTALS d CURBS
PER PLAN
D PE
DESTAL NOTE::
PEDESTALS SHALL
X BE POURED MONOLITHICALLY
/ Q WITIH FOOTINGS, NO GOLD
/ JOINTS SHALL BE PERMITTED.
SEE PEDESTAL PLANS
1-#3 TIE I" BELOW
TOP OF FOOTING
TYP
#5 ® I5"0,.c.TRAN5 U.O.N.
TOP d BOTTOM
Q EXCEPT AT ID
m BOTTOM LONGITUDINAL
REINFORCING PER SCHEDULE
1pre-S
-KV
ul
TYPE �@ PEDESTAL PLAN
TYPE A B G D REIN'".
IA 10'-0" 5'-0" 2'-O" 4'-6" 4 -#5 i
IB „ 5 -#5 EA. WAY 4 - #5 VERT. N ( 3/4" CHAMFER
6'-4" 6'-4" 2'-O' 3'-2 TOP d BOTTOM REINF. DOWELS NP
O
4'_O" 4'-O" 2'-O" W 4 -#5 EA. AY 4- %" F1554 A.D.
I G I '-b" TOP d BOTTOM /
LOCATION PER i CONCRETE
VP ANCHOR PLAN c PEDESTAL _
O I o -,
#3 TIES ®6 o.c. '
AROUND PEDESTAL to
VERT. REINF. -
SEE 3-#3 TIES
WITHIN TOP 6" -- SIJILDING LINE
AT DETAIL I
TYPEfO PEDESTAL PLAN
!
I
-0 0
2- !/a" F1554 A.B.
LOCATION PER
VP PLAN ,
FOR ITEMS NOT
NOTED SEE TYPE I
PEDESTAL PLAN - 4— -
TYPE ID PEDESTAL PLAN
11
0
-—CE3
0
FOR ITEMS NOT
NOTED SEE TYPE
PEDESTAL PLAN
o _
2- 5/a" F1554 A.B: o
LOCATION PER
VP PLAN
TOP OF PEDESTALS SHALL
G
/ I MATCH TOP OF CURES
TYPE III PEDESTAL PLAN
i
_ 8/2" GONG.
MS NOT CURB
SEE TYPE I
AL PLAN
of
2- 3/a" F1554 A.B.
LOCATION PER =
VP PLAN
LLJ
BUILDING LINE
TYPE II PEDESTAL PLAN
PERMIT # +'✓� -
BUTTE COUNT
Q�pFESS/pN
J. DD�q��
co
w No.42028 m
* Exp. 03/31/16
'SERVICES `P�q/ CNIL ���P
REVIEWED FOR 4z OF
CO COMPLIANCE AUG z 2015
DATE � 1 - - - - -- C�Z-
REVISIONS I BY
O�
W a } N
�a m
�
mZ83Q
.2 F,U-j
p X W
.J 0 m i.+ 0 .'.i
z
._ . a 0, = O
*o 0 0 1-
.r` d
Uf Q
- °^
x U
z�pco
c� a U
b
8/18/2015
SCALE
UON
DRAWN
djd
JOB
15033
SHEET
OF SHEETS
---- ...
- -
--_ _-
---
-- --
----
__ __
-- -
--- --�
r
I,
i__. _._ -_ _ _... _ _ _ - _---
� _. _. ._--•- _- _ - __ _ _ �_.. __- _ ___ --__ _.---T-__
.._....r.. _ _. _ __- - -_
..a.J.�......Y.wr.IJa.�.-.u.qui....,....u.a.��..._..�......_.�._.,...,�_._...v......._._........�.�..Y..._�_____.�......_. � '� ... .. .. � �.. �. .. ... ... .._ .. 1 _... � ... � � _.... .. ....._�._..._._._ _ _ ..w.LLr...�s. .iL.a.�u.n.JLL�..ed..