HomeMy WebLinkAboutB15-2409Array: { ,• .1 w Modules: (30) SolarWorld SW285 Mono Black 285W Modules Inverters: (30) Enphase Energy M250,240W AC Microinverters Mounting Method: Tilt mounted at 23.5° DEG.' -,(30) modules Ironridge roof mount system with XR100 rail Array Azimuth: (30) Modules at 180 t N� Depicts Cal Fire Setback Requirements A: (Existing) All -in -one utility meter and main service panel, 200A, 120/240V, 1 ' B: (New) PV system dedicated 125A, AC aggregate panel (2) back -fed PV circut`breakers C: (New) Wire Runs D: (2) (New) PV system junction box (UL 1741, NEMA 3R) (Located behind modules) . • t PV System Equipment Wall (Plan View) Equipment Wall (At Service Entrance) A B C - Array D — i 4OV�JNER � / JOB Array: { ,• .1 w Modules: (30) SolarWorld SW285 Mono Black 285W Modules Inverters: (30) Enphase Energy M250,240W AC Microinverters Mounting Method: Tilt mounted at 23.5° DEG.' -,(30) modules Ironridge roof mount system with XR100 rail Array Azimuth: (30) Modules at 180 t N� Depicts Cal Fire Setback Requirements A: (Existing) All -in -one utility meter and main service panel, 200A, 120/240V, 1 ' B: (New) PV system dedicated 125A, AC aggregate panel (2) back -fed PV circut`breakers C: (New) Wire Runs D: (2) (New) PV system junction box (UL 1741, NEMA 3R) (Located behind modules) . • t PV System Equipment Wall (Plan View) Equipment Wall (At Service Entrance) A B C - Array D — 4OV�JNER � / JOB Mr. Josh Hubbard 13999 Lindbergh Cir., t, • .f Chico, CA 95973 APN:047-740-001 c li t V CONTRACTOR �f r North State Solar Energy �` PO Box 899 Forest Ranch, CA 95942 i Lic# 813508 L Ia• ? PROJECT DETAILS New 8KW solar PV roof mount system using microinverters on Iron Ridge racking system tied into existing load center. All • wiring is AC. U Page 2 (30) 240 WATT Utility Interactive Inverters. ' Enphase M250 -60-240-S22 . Page Details: CEC Model: Enphase M250-60-2LL-S2x (-ZC)(-NA)(240V) Single Line Diagram for .� _ CEC-Inverter Efficiency: 96.5% Mr. Josh Hubbard240VAC, 10, 60Hz ` Voltage and Phase Sensing Neutral . • x Project Details: Listed to UL 1741 } New 8KW Roof Mount PV Array 48 VDC Max Input Voltage using microinverters on Iron •_: _ Integrated G.E.C. Ground ; Ridge mounting system going to . main residence. PV Circut: (15) SolarWorld SW285 Mono Black Module Module Module _ 285W Modules , Junction Box t x NEMA 3R� •UL 1741 ' • ' - - � Microinverter Microinverter �^ Microinverter ' . (At Array) ' PV Circut: , (15) SolarWorld SW285 Mono Black Module Module Module 285W Modules Microinverter Microinverter Microinverter r # 240 VAC Enphase AC ` Engage Cable c 240 VAC - And Bare #6 AWG h 4 - #12 AWG THWN-2 CU (Existing) E.G.C. Ground 1 - #12 AWG THWN-2 CU Neutral Utility Meter i- 1 - #8 AWG THWN-2 CU E.G.C. (Gnd to be continuous) 3/4" LFMC Conduit 240 VAC 140 (Run behind array) 2 - #8 THWN-2. CU y 1 - #8 THWN-2 CU Neutral - 1 - #8 THWN-2 CU E.G.C. Meter Panel (GND TO BE CONTINUOUS) 1 " LFMC Conduit (Run Along Equipment Wall). 20A i l e ' 20A c 40A ' Breaker Dedicated PV System AC Aggregate Panel' 120/240 VAC, 125 AMP, NEMA 3R Main Lug Only + (2) 2P -20A PV Circut Breakers fi (Located at array) 1 • I r ;SHEET INDEX VICINITY MAP . SYSTEM INFORMATION. , PROPERTY.oF . . . ALL DESIGN PARAMETERS LITE OMUST BE CONFIRMED AND ADJUSTED TO MEET SITE SPECIFIC ' CONDITIONS OF USE. INSTALLING DEALER HAS - SOLE RESPONSIBILITY FOR THE CORRECT PV -01 . TITLE SHEET. - SYSTEM SIZE: 5.61 KW. - ' ,qyc :Cz s 'i' ;' ' ---'W...--�-."—' - s--' • �" r PV MODULE: (22) CANADIAN SOLAR CS6P-255P •T PV -02 SITE R ARRAY LAYOUT PV -04 ELECTRICAL DIAGRAM RACKING: UNIRAC 7, • «, `�'i. r : INVERTERS(22) ENPHASE M215 MICROINVERTERS '.�' .r a d- • • SELECTION AND INSTALLATION OF ALL EQUIPMENT AND MATERIALS TO MEET ANY POW ER PRODUCTION COMMITMENTS AND ALLLOCAL/NATIONALCODEANDSAFETY _ .' REQUIREMENTS. PV -05 ELECTRICAL CALCULATIONS . �• •-•� .a a ' •f 1 �� . ® •, p�g.�}. �• •.' - Elite Solar • SCOPE OF WORK-, • = :..�.,�e..0 .. - ,rte / ," b „ �_ - INSTALLATION CONSISTS OF (22) CANADIAN SOLAR CS6P-255P, (22) .� r '. EP 15 PEPSI WAY DURHAM, CA 95938 r „ • ., ; .. r s �. . .. _ ENPHASE M215 MICROINVERTERS WITH MONITORING SYSTEM AND (530)345-9910 • RELATED MOUNTING AND SAFETY EQUIPMENT. WWW.ELITESOLARCA.COM J CSLB# 930561 C46 ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE APPLICABLE CODES - Ia'r WARRANTED / "_" .i �. ' ALL EQUIPMENT WILL BE INSTALLED AS REQUIRED BY APPLICABLE CODES, PROJECT INFORMATION - 2011 NATIONAL ELECTRICAL CODE (NEC) AND LOCAL UTILITY COMPANY REQUIREMENTS. • NAME: - 2013 CALIFORNIA ELECTRICAL CODE (CEC) _ _ ;_ _ ,�,,�-' � • { ; ' � '= `` *t�-' ` David &Marilyn Elwell - 2013 CALIFORNIA BUILDING CODE (CBC) - 2012 INTERNATIONAL BUILDING CODE (IBC) �i - - ; •,�-k_ roonEsi 4760 Seacrest Drive Oroville, CA 95966 PHONE: ABREVIATIONS. CONSTRUCTION NOTES � •' A, Butte County - A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS - (E) EXISTING�•. . ' ( APM: (N) NEW -',THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES -" ' ' 078-320-039-000. GND GROUND :. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH NEC 690-0, AND 250-50 THROUGH 60 250-166 SHALL BE PROVIDED. PER NEC, GROUNDING ELECTRODE SYSTEM OF PROJECTN: PNL PANEL BOARD OR PANEL EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A 15-82 J -BOX JUNCTION BOX SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. GROUNDING MSP MAIN SWITCH PANEL.; ' ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A PVC POLYVINYL CHLORIDE COMPLETE GROUND. EMT ELECTRIC METAL TUBING + FMC FLEXIBLE METAL CONDUIT = EACH MODULE WILL BE GROUNDED USING THE SUPPLIED GROUNDING POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION MANUAL. AHJ SIGNATURE AND DATE NEMA NATIONAL ELECTRIC MANUFACTURES ASSOCIATIO EXPOSED NON-CURRENT CARRYING METAL PARTS OF MDULE FRAMES, EQUIPMENTS, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR ` r 250.136(A) REGARDLESS OF VOLTAGE.ti , = %PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION 110.26 CEC., SYMBOL'S' KEY EQUIPMENT MANUFACTURER' - ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC, ENGRAVED iN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED USING AN APPROVED METHOD. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. . REVISION SCHEDULE M METER O PHOTOVOLTAIC MODULES: CANADIAN SOLAR www.canadiansolar.com' - ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY 2013 CEC AND 2011 NEC. No. Date Description INVERTER +, -. HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6'-7" PER NEC 240.24. 1 9/30/15 Rev 1.0 - THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEEN THE GROUNDING ELECTROD AND THE PANEL (OR INVERTER) IF SMALLER — GROUND _ THAN #6 AWG COPER WIRE PER NEC 250-64B. THE GROUNDING ELECTRODE. CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER NEC 250.64C.� . RACKING O� SWITCH _ SITE CONDITIONS SHALL PREVAIL. IF NO SCALE IS GIVEN; DRAWINGS ARE NOT TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR AND DRAWN BY: EC wwIRAc w.unirac.com , SUBCONTRACTORS IN THE FIELD UPON COMMENCEMENT OF CONSTRUCTION. 'Y APPROVED BY: DR FUSE 's M : + DATE: 9/30/15 0- 0 BREAKER Y +_ r SHEET TITLE - INVERTER:•. TITLE SHEET CONDUIT RUN EXTERIOR. ,°+ '- -' ENPASE SHEET NUMBER www.enphase.com ✓ /, (//, } + b- ,'S Y PV -01 CONDUIT RUN_ z "tr. ' ` _ - —r INTERIOR • r ' ' ,• 7, - � •e - E. _ • - .tiK - l 1 inch INTERNET - '� , - r ` s���t 2015. Oft Sollot ar -f 0 U) NW LL U Q W. U) v< SOLAR EQUIPMENT • (N) SOLAR SUB -PANEL • (N) INVERTERS # 1-7 4 4 <===DRIVEWAY===> PROPERTY OF ELITE SOLAR ' ALL DESIGN PARAMETERS MUST BE CONFIRMED AND ADJUSTED TO MEET SITE SPECIFIC CONDITIONS OF USE. INSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT SELECTION AND INSTALLATION OF ALL • EQUIPMENT AND MATERIALS TO MEET ANY POWER PRODUCTION COMMITMENTS AND ALL - - LOCAL/NATIONAL CODE AND SAFETY - REQUIREMENTS. �e o O. 0®-• •.• 00.E O 6 0.47 Ac I ' g o.e • . • 4! Eke.: Sola_:r . ` 15 PEPSI WAY DURHAM, CA 95938 (530)345-9910 WWW.ELITESOLARCA.COM CSLB# 930561 C46 i PROJECT INFORMATION NAME: David & Marilyn Elwell ADDRESS: 4760 Seacrest Drive: CITY: Oroville, CA 95966 PHONE: AHJ: Butte County APNi: 078-320-039-000 PROJECTM 15-82 _ s 0' 7.5' 15' 30' .Scale 1" = 15' _ For 11x17" Print f. t. R' AHJ SIGNATURE AND DATE J • REVISION SCHEDULE No. Date Description � I _ _ • ` PROJECT INFORMATION NAME: David & Marilyn Elwell ADDRESS: 4760 Seacrest Drive: CITY: Oroville, CA 95966 PHONE: AHJ: Butte County APNi: 078-320-039-000 PROJECTM 15-82 _ s 0' 7.5' 15' 30' .Scale 1" = 15' _ For 11x17" Print f. t. R' AHJ SIGNATURE AND DATE REVISION SCHEDULE No. Date Description 1 9/30/15 Rev 1.0 _ _ • ` DRAWN BY: EC APPROVED BY: DR DATE: 9/30/15 SHEET TITLE SITE & ARRAY LAYOUT SHEET NUMBER PV -02 1 1 inch Scale to Confine 11•x17' Plot @COPY*t 2m4 Alto sdur _ _ • ` TTAG DESCRIPTION 1 BRANCH OF PV MODULES 2 MAIN SERVICE PANEL COMPONENT. COMMENTS (22) CANADIAN SOLAR CS6X-315P (22) ENPHASE M215. MICROINVERTERS NOTE:. 100A RATED, 240V, 10 WITH 90A MAIN BREAKER IDERATE MAIN BREAKER FROM 100A Conductor sized per NEC 230.42(B)• L (E) MAIN SERVICE PANEL 100A, 240V, 10 90A/2P 4 -(E) LOADS ----0 0- 15A/2P 15A/2P 11 PV MODULES WITH MICROINVERTERS �- 15A/2P 11 PV MODULES WITH MICROINVERTERS - L--------------------------- ----- MOUNTING STRUCTURE CONDUCTOR, CONDUIT AND VOLTAGE DROP SCHEDULE - SYSTEM 'B' CONTINUOUS CONTINUOUS OCP DERATES CONDUCTOR CURRENT CARRYING CONDUCTOR EGC/GEC TAG CIRCUIT CURRENT (A) CURRENT X 1.25 (A) SIZERAREQUIRED CONDUCTORS AMPACITY (A) T(amb) CEWAY AMPACITY(A) SIZE(min) TYPE (PER NEC 310.16) SIZE(min) T (TYP OF 2 O PV SOURCE) 9.90 12.38 15 0.82 1.00 15.09 #10 AWG THWN-2 35 #10 AWG TI ) (or eq.) (ol i CONDUIT VOLTAGE (V) ONE WAY' VOLTAGE DROP SIZE TYPE DISTANCE FT) (% AT 75°C) 1 runs) EMT/PVC 240 140 0.70% t PROPERTY OF ' ELITE SOLAR ' ALL DESIGN PARAMETERS MUST BE CONFIRMED AND ADJUSTED TO MEET SITE SPECIFIC . CONDITIONS OF USE. INSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT SELECTION AND INSTALLATION OF ALL . EQUIPMENT AND MATERIALS TO MEET ANY . POWER PRODUCTION COMMITMENTS AND ALL LOCAUNATIONAL CODE AND SAFETY REQUIREMENTS. O •oeo•• o,e_o. Elite Solar 15 PEPSI WAY DURHAM, CA 95938 (530)345-9910 WWW.ELITESOLARCA.COM CSLB# 930561 C46 PRn.IFC.T INFnRMATIOKI NAME: David & Marilyn Elwell ADDRESS: 4760 Seacrest Drive CITY: Oroville, CA 95966 ANJ: Butte County APNS: 078-320-039-000 PROJECTI: 15-82 AHJ SIGNATURE AND DATE REVISION SCHEDULE No. Date Description 1 9/30/15 Rev 1.0 DRAWN BY: EC APPROVED BY: DR DATE: 9/30/15 SHEET TITLE ELECTRICAL DIAGRAM SHEET NUMBER PV -03 L 1 inch I Sty�le'to Confirm 11'x17' Plat @upwt It 2014 Este Sdw DESIGN TEMPERATURES LOWEST EXPECTED TEMPERATURE 26.6-F AVERAGE HIGH TEMPERATURE ` 97-F PV MODULE ELECTRICAL SPECIFICATIONS —WARNING MANUFACTURER CANADIAN SOLAR MODEL CS6X-315P PMAX (NOMINAL OUTPUT POWER) 315 W VMP (VOLTAGE AT PMAX) 36.6 V IMP (CURRENT AT PMAX) ' 8.61 A VOC (OPEN CIRCUIT VOLTAGE) 45.1 V , ISC (SHORT CIRCUIT CURRENT) 9.18 A VOC TEMPERATURE COEFFICIENT -0.34 1 %/'C " DC SOURCE INFORMATION (CS6X-315P) a, ,`• 4 - f NUMBER OF PV MODULES 22 MODULES MAXIMUM MODULES PER STRING 20 MODULES _ MAX. STRING VOC (I x VOC) 45.1 V MAXIMUM DC SYSTEM VOLTAGE: —WARNING Max. String Voc x (1 + [(T_low - 25) x T_coeff.]): o e v ' 4 0®� 1.ite- Elite-�-� 45.1 x {1 + [(-3 - 25 ) x -0.0034]) = 49.39 V AC NORMAL OPERATING VOLTAGE - 240 V LT :. SIGNAGE' ' { . t . ENPHASE M215 NOMINAL AC POWER 215 W NOMINAL OUTPUT VOLTAGE 240 V NOMINAL OUTPUT CURRENT 0.9 A OCP SIZE 15 A MPPT_MIN AT FULL POWER 16 V MPPT_MAX AT FULL POWER 48 V MAXIMUM DC VOLTAGE 48 V REVISION SCHEDULE -o.— ", EQUIPMENT AND MATERIALS TO MEET -ANY No. Date -Description POWER PRODUCTION COMMITMENTS AND ALL ,{ .''•`•, LOCALMATIONAL CODE AND SAFETY 4",Sri +.'r - . ,} 4 REQUIREMENTS. DC SOURCE INFORMATION (CS6X-315P) a, ,`• 4 - f NUMBER OF PV MODULES 22 MODULES MAXIMUM MODULES PER STRING 20 MODULES _ MAX. STRING VOC (I x VOC) 45.1 V MAXIMUM DC SYSTEM VOLTAGE: —WARNING Max. String Voc x (1 + [(T_low - 25) x T_coeff.]): o e v ' 4 0®� 1.ite- Elite-�-� 45.1 x {1 + [(-3 - 25 ) x -0.0034]) = 49.39 V AC NORMAL OPERATING VOLTAGE - 240 V LT INVERTER ELECTRICAL SPECIFICATIONS MANUFACTURER ENPHASE MODEL , ENPHASE M215 NOMINAL AC POWER 215 W NOMINAL OUTPUT VOLTAGE 240 V NOMINAL OUTPUT CURRENT 0.9 A OCP SIZE 15 A MPPT_MIN AT FULL POWER 16 V MPPT_MAX AT FULL POWER 48 V MAXIMUM DC VOLTAGE 48 V REVISION SCHEDULE -o.— ", EQUIPMENT AND MATERIALS TO MEET -ANY No. Date -Description POWER PRODUCTION COMMITMENTS AND ALL ,{ .''•`•, LOCALMATIONAL CODE AND SAFETY 4",Sri +.'r - . ,} 4 REQUIREMENTS. i... '! # .+ , e - t ra.. INTERIORIEXTERIOR ' `- CAUTION'SOL=AR'CIRCUIT ' ; I t L. f LLL111 L ARRAY with MICROINVEI 15 PEPSI WAY DURHAM, CA 95938 (530)345-9910 WWW.ELITESOLARCA.COM s . .'r CSLB# 930561 C46 PROJECT INFORMATION v NAME: David & Marilyn Elwell _ ADDRESS: 4760 Seacrest Drive CnY: Oroville, CA 95966 PHONE: AIU: Butte County - APNO: 078-320-039-000 PROJECTM 15-82 —WARNING o e v ' 4 0®� 1.ite- Elite-�-� DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM PROPERTY OF AC NORMAL OPERATING VOLTAGE - 240 V LT ELITE SOLAR. a . T " + `• ALL DESIGN PARAMETERS MUST BE CONFIRMED • - - . AND ADJUSTED TO MEET SITE SPECIFIC _ CONDITIONS OF USE. INSTALLING DEALER HAS SOLE RESPONSIBILITY FOR THE CORRECT + -• SELECTION AND INSTALLATION OF ALL REVISION SCHEDULE -o.— ", EQUIPMENT AND MATERIALS TO MEET -ANY No. Date -Description POWER PRODUCTION COMMITMENTS AND ALL ,{ .''•`•, LOCALMATIONAL CODE AND SAFETY 4",Sri +.'r - . ,} 4 REQUIREMENTS. i... '! # .+ , e - 15 PEPSI WAY DURHAM, CA 95938 (530)345-9910 WWW.ELITESOLARCA.COM s . .'r CSLB# 930561 C46 PROJECT INFORMATION v NAME: David & Marilyn Elwell _ ADDRESS: 4760 Seacrest Drive CnY: Oroville, CA 95966 PHONE: AIU: Butte County - APNO: 078-320-039-000 PROJECTM 15-82 —WARNING o e v ' 4 0®� 1.ite- Elite-�-� DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM _ ` TED AC O T T C RRENT -15 AMPS AC NORMAL OPERATING VOLTAGE - 240 V LT 15 PEPSI WAY DURHAM, CA 95938 (530)345-9910 WWW.ELITESOLARCA.COM s . .'r CSLB# 930561 C46 PROJECT INFORMATION v NAME: David & Marilyn Elwell _ ADDRESS: 4760 Seacrest Drive CnY: Oroville, CA 95966 PHONE: AIU: Butte County - APNO: 078-320-039-000 PROJECTM 15-82 ... �♦t 7 r � � ` i +,��� rJ... - � � � r ^ ,�'�- ! .'�f � . � nH rtryr+ fi`` *- - T - �- � � r AHJ SIGNATURE AND DATE 4 ' ' t• { ''' ; REVISION SCHEDULE 4t� No. Date -Description 1 9/30/15 Rev 1.0 4",Sri +.'r - . ,} 4 ' _ • s_ # .+ , e - DRAWN BY: EC APPROVED BY: DR - DATE: 9/30/15 SHEET TITLE `' ` ��' + r `"` �+ • ELECTRICAL CALCULATIONS ' ,,:• SHEET NUMBER } PV -04 «.. 1 • - �'7 2 Scale to Confirm 11"x17" Plot .,-• - _ , Q'apKlght 2014 Ellie Solar ... �♦t 7 r � � ` i +,��� rJ... - � � � r ^ ,�'�- ! .'�f � . � nH rtryr+ fi`` *- - T - �- � � r MAX POWER CS6X-31013151320P High quality and reliability in all Canadian Solar modules is ensured by 14 years' experience in module manufacturing, well -engineered module design, stringent BOM quality testing, an automated manufacturing process and 100 % EL testing 1 'fr i j , fjJ ilk •. I Y 11r j( it � li�f tip y _ k MODULE / ENGINEERING DRAWING (mm) CS6X-310P / I-V CURVES •A r A Rear View Frame Cross Section A -A 110. n _. _ _ 1o. 35NN m 0 600 WWL s'25s1 insurance -backed warranty ` •_ 0 400 W on' - 65°C 0 years.., non -cancellable, immediate warranty insurance KEY FEATURES _ . linear power output warranty MODULE / MECHANICAL DATA + � Excellent module efficiency � _ • �Q � producton materials ( warranty Nominal Max. Power (Pmax) 310 W 315 W 320 W 8.11.7 up to 16.68% years and workmanship Cell Arrangement Mounting Opt. Operating Current (Imp) 8.52A 8.61A 8.69 A' Dimensions hole Open Circuit Voltage (Voc) 44.9 V 45.1 V 45.3 V 'Weight ........................................................................................ Short Circuit Current (Isc) 9.08 A 9.18 A 9.26 A Front Cover Outstanding low irradiance MANAGEMENT SYSTEM CERTIFICATES*Tn .. f performance > 96.0% ISO 9001: 20081 Quality management system IP67, 3 diodes _ Cable ISO/ I"S 16949: 2009 / The automotive industry quality management system Module Fire Performance TYPE 1 (UL 1703) or r DWP Positive power tolerance ISO 14001: 2004 / Standards for environmental management system OHSAS 18001: 2007 / International standards for occupational health & safety Connectors or MC4 comparable upto5W Stand. Packaging _MC4 26 pcs, 620 kg Application Classification Class A ' ,PRODUCT CERTIFICATES* Power Tolerance 0 --+ 5 W No.1 ' IEC 61215 / IEC 61730: VDE / MCS / CE / SII / CEC AU / CQC / INMETRO' UL 1703 / IEC 61215 performance: CEC listed (US) per Container PTC High PTC rating Up to 91.97% UL 1703: CSA / IEC 61701 ED2: VDE / IEC 62716: VIDE / IEC 60068-2-68: SGS - - - - -- 1.5 and cell temperature of 25°C. - , PV CYCLE ((_EU)) / UNI 9177 Reaction to Fire: Class 1 ELECTRICAL DATA / NOCT* ,TEMPERATURE CHARACTERISTICS Electrical Data CS6X 310P 315P 320P �E SP �:• BBA✓ ) PVCYCLE it CERT Data Nominal Max. Power (Pmax) 225 W 228 W 232 W IP67 junction box for long-term Opt. Operating Voltage (Vmp) 33.2 V 33.4 V 33.6 V _ Temperature Coefficient (VOC) -0.34% /'C T IP67 Weather endurance • As there are different certification requirements in different markets, please contact z - Short Circuit Current (Isc) 7.36 A 7.44 A 7.50 A your local Canadian Solar sales representative for the specific certificates applicable to • Under Nominal Operating Cell Temperature (NOCT), irradiance of 800 WW, • the products in the region in which the products are to be used. - - PARTNER SECTION 1F �F is Heavy snow load up to 5400 Pa load 2400 Pa ............................................. CANADIAN SOLAR INC. is committed to providing high quality ` PERFORMANCE AT LOW IRRADIANCE wind up to Industry leading performance at low irradiation, +96.0 % solar products, solar system solutions and services to customers 200 W/m2 (AM 1.5, 25°C). around the world. As a leading manufacturer of solar modules and 1 _ Salt mist, ammonia and blowing sand PV project developer with about 10 GW of premium quality The specification and key features described in this Datasheet may deviate slightly w•* . - w resistance, apply to seaside, farm and modules deployed around the world since 2001, Canadian Solar desert environments Inc. (NAS-DAQ: CSIQ) is one of the most bankable solar companies .. .. ..I ..................... .......................... worldwide. ....... ........ .................. .......... _.............. ................................. the most recent version of the datasheet which shall be duly incorporated into CANADIAN SOLAR INC. the binding contract made by the parties governing all transactions related to the ' 545 Speedvale Avenue West, Guelph, Ontario N1 K 1 E6, Canada, www.canadians6lar.com, support@canadiansolar.com purchase and sale of the products described herein. f ' Caution: For professional use only. The installation and handling of PV modules _ k MODULE / ENGINEERING DRAWING (mm) CS6X-310P / I-V CURVES •A r A Rear View Frame Cross Section A -A 110. n _. _ _ 1o. 35NN m 8 - r-- _.. _ 8 _ __ _. 7 7 _ 6 V 6 - 5 _ ._ .__ __- _. _ _ 5. _ __. _. ____ -_ . - '___ . ,4. 4. 2 11 ~712 o_. -. _ _ MountingHole o s 10 15 zo zs 30 35 ao as s 10 a zo zs 30 3s do ds so 7 R ■ 1000 W/m' 5°c ■ 11111. 800 W/m' 25°C ■ p 932-7 982 1 LT 0 600 WWL d5°C O 0. Grounding •_ 0 400 W on' - 65°C 0 ole ELECTRICAL DATA / STC* MODULE / MECHANICAL DATA Electrical Data CS6X 310P 315P 320P 2-05 Data Nominal Max. Power (Pmax) 310 W 315 W 320 W 8.11.7 A Opt. Operating Voltage (Vmp) 36.4 V 36.6 V 36.8 V Cell Arrangement Mounting Opt. Operating Current (Imp) 8.52A 8.61A 8.69 A' Dimensions hole Open Circuit Voltage (Voc) 44.9 V 45.1 V 45.3 V 'Weight 8 - r-- _.. _ 8 _ __ _. 7 7 _ 6 V 6 - 5 _ ._ .__ __- _. _ _ 5. _ __. _. ____ -_ . - '___ . ,4. 4. 2 11 ~712 o_. -. _ _ MountingHole o s 10 15 zo zs 30 35 ao as s 10 a zo zs 30 3s do ds so 7 R ■ 1000 W/m' 5°c ■ 11111. 800 W/m' 25°C ■ p 932-7 982 1 LT 0 600 WWL d5°C O •_ 0 400 W on' - 65°C 0 ELECTRICAL DATA / STC* MODULE / MECHANICAL DATA Electrical Data CS6X 310P 315P 320P Specification Data Nominal Max. Power (Pmax) 310 W 315 W 320 W Cell Type Poly -crystalline, 6 inch Opt. Operating Voltage (Vmp) 36.4 V 36.6 V 36.8 V Cell Arrangement 72 (6 x 12) Opt. Operating Current (Imp) 8.52A 8.61A 8.69 A' Dimensions 1954x982x4Omm(76.93x38.7x1.57in) Open Circuit Voltage (Voc) 44.9 V 45.1 V 45.3 V 'Weight 22 kg (48.5 lbs) Short Circuit Current (Isc) 9.08 A 9.18 A 9.26 A Front Cover 3.2 mm tempered glass Module Efficiency 16.16% 16.42% 16.68% Frame Material Anodized aluminium alloy Operating Temperature -40°C - +85°C J -BOX IP67, 3 diodes Max. System Voltage 1000 V (IEC) or 1000 V (UL) Cable 4 mm2 (IEC)or 4 mm2 & 12 AWG Module Fire Performance TYPE 1 (UL 1703) or r _ 1000V (UL), 11 SO mm(45.3 in) CLASS C (IEC 61730) Connectors or MC4 comparable Max. Series Fuse Rating 15A Stand. Packaging _MC4 26 pcs, 620 kg Application Classification Class A (quantity & weight per pallet) Power Tolerance 0 --+ 5 W Module Pieces 624 pcs (40' HQ) r per Container * Under Standard Test Conditions (STC) of irradiance of 1000 W/m', spectrum AM - -• ---• ------ - - - - -- 1.5 and cell temperature of 25°C. - , ELECTRICAL DATA / NOCT* ,TEMPERATURE CHARACTERISTICS Electrical Data CS6X 310P 315P 320P Specification Data Nominal Max. Power (Pmax) 225 W 228 W 232 W _ Temperature Coefficient (Pmax) -0.43%/ °C• Opt. Operating Voltage (Vmp) 33.2 V 33.4 V 33.6 V _ Temperature Coefficient (VOC) -0.34% /'C T Opt. Operating Current (Imp) 6.77 A 6.84 A- 6.91 A Temperature Coefficient (Isc) 0.065% /'C Open Circuit Voltage (Voc) 41.3 V 41.5 V 41.6 V Nominal Operating Cell Temperature 4512'C Short Circuit Current (Isc) 7.36 A 7.44 A 7.50 A • Under Nominal Operating Cell Temperature (NOCT), irradiance of 800 WW, - spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. PARTNER SECTION PERFORMANCE AT LOW IRRADIANCE Industry leading performance at low irradiation, +96.0 % module efficiency from an irradiance of 1000 W/m2 to 200 W/m2 (AM 1.5, 25°C). - The specification and key features described in this Datasheet may deviate slightly w•* . - w , and are not guaranteed. Due to on-going Innovation, research and product - •' ° enhancement Canadian Solar Inc. reserves the right to make any adjustment to thein formation described herein at any time without notice. Please always obtain : r,` the most recent version of the datasheet which shall be duly incorporated into the binding contract made by the parties governing all transactions related to the purchase and sale of the products described herein. f ' Caution: For professional use only. The installation and handling of PV modules requires professional skills and should only be performed by qualified professionals. Please read the safety and installation instructions before using the modules. ••••*.•••..••• ••••• ......................... •-••••-•• •-••••-••• ••- • ............................ ....... I....................................................................... CANADIAN SOLAR INC. July 2015. All rights reserved, PV Module ............................................... _ Product Datasheet I V5.2 -EN t Enphase®Microinverters Enphase@M215 The E -- nhm;e' M213 Vt, erli e with integrated ground delivers increased energy harvest and reduces design and installation complexity with its all -AC approach. With the advanced M215, the DC circuit is isolated and insulated from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This further simplifies installation, enhances safety, and saves on labor and materials costs. The Enphase M215 integrates seamlessly with the Engage® Cable, the Envoy® Communications Gateway", and Enlighten®, Enphase's monitoring and analysis software. PRODUCTIVE SIMPLE 1 - Maximizes energy production - No GEC needed for microinverter - More than 1 million hours of testing - Minimizes impact of shading, - No DC design or string calculation and millions of units shipped ' dust, and debris required - Industry-leading warranty, up to 25 - No single point of system failure - Easy installation with Engage years Cable r enphase6 LJENERGY Enphase® M215 Microinverter //,DATA INPUT DATA (DC) 'M215-60-2LL-S22-IG, M215-60-2LL=S25-IG Recommended input power (STC)0- j7; w _ -- _ - - — Maximum input DC voltage 48 V t�_ _ __ Peak Powe trr acking voltage rl =27 V -39 - Operating range:... � 16 V - 48 V� � � � „" .4;' �14 M M art voltage - V _ X22 748 V — ' T - s - R r4 Max DC short circuit current 15 A OUTPUT DATA (AC) ®208 VAC 0240 VAC Peak output power - 225 W- —x225 Wy ::" Rated (continuous) output power .r . �...� .. — . T... . 215 W 215 W F. Nominal output current -- - = 1.03A (A rm_s at nominal duration) _ 0 9 A (A rms at n_ominal_duration) Nominal voltage/range 208 V / 183-229 V 240 V / 211-264 V F Nominal frequency/range: _ - = 60 0 / 57_61 Hz _ __ y _— ^ -60-.O,/57 61 Hz- �57-62.5 Extended frequency range' Hz 57-62.5 Hz Power factor >0.95 >0.95 Maximum units per 20 A branch circuit 25 (three phase) 17 (single phase) Maximum output fault current 850 mA rms for 6 cycles 850 mA rms for 6 cycles EFFICIENCY CEC weighted efficiency, 240 VAC 96.5% CEC weighted efficiency, 208 VAC 96.5% Peak inverter efficiency 96.5% _ Static MPPT efficiency (weighted, reference EN50530) 99.4% Night time power consumption 65 mW max MECHANICAL DATA Ambient temperature range -40°C to +65°C Dimensions (WxHxD) 171 mm x 173 mm x 30 mm (without mounting bracket) Weight 1.6 kg (3.4 lbs) Cooling Natural convection 'No fans Enclosure environmental rating Outdoor - NEMA 6 Connector type M215-60-2LL-S22-IG: MC4 M215-60-2LL-S25-IG: Amphenol H4 FEATURES Compatibility - r Compatible with 60 -cell PV modules_ Communication Power line Integrated ground _ The DC circuit meets the requirements for ungrounded PV arrays in t - NEC 690 35:.Equipment ground Is provided in the Engage Cable_.'No ~additional E r round is'r-` cared: Ground'fault 'rotectlon' FP `is.; : i integrated into the:microinverter. T n= Monitoring Enlighten Manager and MyEnlighten monitoring options Compliance 7_UL1741/IEEE1547, FCC Part 15 Class B, CAN/CSA-C222 N0. 0=M91; - _ r N; 0.4-04, and 107.1-01 = ... . Frequency ranges can be extended beyond nominal if required by the utility 41 To learn more about Enphase Microinverter technology, C us visit enphase com © 2015 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. rr 1jenphase- L J E N E R G Y MKT -00069 Rev 1.0 January 13, 201.4 ESSIO X40 ENNE Th ��\\ r�Iml � � UniRac I ¢ m'1 1411 Broadway Boulevard NE' I(� Albuquerque, New Mexico 87102-1.545 +;i �No .s367a TEL: (505) 242-6411 FAX: (505) 242-6412 'grFcTUR CA��� CFIS Attn.: Engineering Department, Re: Engineering Certification for UniRac's SolarMount Code -Compliant Installation Manual 227.3 PZSE, Inc. -Structural Engineers has reviewed UniRac's "SolarMount Code -Compliant Installation Manual 227.3" published January 2014 and specifically "Part I. Procedure to Determine the Design Wind Load", and "Part Il: Procedure to Select Rail Span and Rail Type". The procedures are used to determine the calculation of the design wind force, load combinations, applied loading and rail selection. All information, data and analysis contained within the Installation Manual are based on, and comply with the following: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-05 and ASCE/SEI 7-10' 2. 2012 International Building Code, by International Code Council, Inc. 3. 2013.California Building Code, by California Building Standards Commission 4. 2010 Aluminum Design Manual, by The Aluminum Association This letter certifies that the structural calculations contained within UniRac's "SolarMount Code -Compliant Installation Manual 227.3 are in compliance with the above Codes. If you have any questions on the above, do not hesitate to call. Sincerely, Paul Zacher, SE -President 8137 Sunset Avenue, Suite 120 • fair Oaks, CA 95628 916.961.3960 • 916.961.3965 f • WWW.PZS[.(OM a I ueftm ® � ITI�� TUVRheinla:nd Certificate no. US 82140038 01 License Holder: Manufacturing Plant: Unirac..Inc. Unirac Inc. 1411 Broadway NE 1411 Broadway NE Albuquerque NM. 87102 Albuquerque NM 87102 USA USA Test report no.: USA- 3 14 4 0 0 2 9 001 Client Reference: John Nagyvary Tested to: Subject 2703 No. 2 (11-13-2012) Certified Product: Module Rack Mounting System License Fee - Units Model Designation: SolarMount (SM) 7 I i Maximum Size of PV Module: 65" long and 39.125" wide I Maximum System Voltage of PV Module: 1000 VDC Maximum overcurrent protection rating of PV Module: 30 A i j Fire hating: Ciass A when installed with T,�pe 1 fire .rated modules, j Type 2 fire rated rnodule " j Type 3i.re rated modules, 'Type 10 moire rated modules. (continued) 7 Appendix: 1,1-4 ' Licensed Test mark: Date of Issue (day/mo/yr) 19/12/2014 Uus TOY Rheinland PTL. LLC, 2210 South Roosevelt Street, Tempe. Arizona 85282, Tol (480) 966-1700, Fax (775) 314-6158 _J Certificate no. US 82140038 02 License Holder: Manufacturing Plant: .Uhirac -Inc. `> , Unirac Inc.- 1411 nca1411 Broadway NE 1411 Broadway NE Albuquerque NM 87102 Albuquerque NM 87102 USA USA. Test report no.: USA -31440029 001 Client Reference: John Nagyvary Tested to: Subject 2703 No. 2.(11-13-2012). Certified Product: Module Rack Mounting System License Fee - Units (continued) 7 Modules Evaluated & Qualified for Mechanical Load: Trina Solar TSM-255PA05.08 Design Load.: Positive= 112 psf, Negative = 50 psf Centrosolar TP6 250 SW and E 250B Design Load: Positive = 112 psf, Negative = 50 psf TSMC Solar TS -150C2 j Design Load: Positive = 35 psf, Negative = 35 psf Modules from the same series with same frame are Qualified if their area is less than or equal to test mociuic. arca. (continued) 7 Appendix: 1,1-4 TUVRheinland Licensed Test mark: , Date of Issue (day/mo/yr) •19/12/2014 TUVRheinla)US • t TGV Rheinland PTL. U.C, 2210 South Roocevett Street, Tempe, Arizona 85282, To (460) 966.1700, Fax (775) 314.6458 till hricate TUVRheinland Cert' Certificate no. 038 03 , • i License Holder. Manufacturing Plant: ' Unirac Inc. Unirac Inc. 1411 -Broadway NE 1411 Broadway NE Albuquerque NM 87102 Albuquerque NM' 87102 AlbUSA Test report no.: USA- 31440029 001 Client Reference: John Nagyvary Tested to; Subject 2703 No. 2. (11-13-2012) Certified Product: Module Rack Mounting. System- License Fee- Units (continued) 7 Modules Evaluated & Qualified for -Electrical -Bonding: AU Optronics (BenQ Solar) PM Series Canadian Solar CS5A-M, CS6P-M, CS6P-P, CSX -P Centrosolar America C -Series, E -Series ET Solar ET AC Module, ET Module Hanwha SolarOne HST, 60 Hyundai. Heavy Industries MG Series (Kyocera KD -F Series i LG El.ec:troi?ics Mono Neon, Mono X Phono Solar Technology All'Standard Modules (continued) Appendix: 1,1-4 - r Licensed Test mark: Date of Issue f (day/mo/yr) ' 19/12/2014 UOS a TUV Rheirand PTL. LLC. 2210 South Roosevelt Strect. Tempo. Arizona 852.82. TO (481)).5166-1701. Fax 1775) 314.6458 unirac,inc. Unirac Inc.. ^ 1411 Broadway NE 1411 Broadway NE Albuquerque NM 87102 Albuquerque NM 87102 ;y USA USA Test report no.: USA- 3144 0029 001 Client Reference: John Nagyvary Tested to: Subject 2703 No. 2 (11-13-2012) Certified Product: Module Rack Mounting System License Fee- Units (continued). 7 Modules Qualified for Electrical Bonding [continued) Renesola All 60 -cell Modules Sharp ND240QCJ, ND240QCS, NDQ235F4 Suniva MV Series, OPTIMUS Series SunPower AC, E -Series, Sig Black,' X -Series Suntech STP XXX Trina PD05, PA05 Yingli. Pandy '60, YGIE 60 `linali_ YGE-Z 60 Sun Edison / MEMC F -Series, R -Series SolarWorld SunModule Protect, SunModule Plus 7 Appendix: 1,1-4 Licensed Test mark: TOVRheinland us Date of Issue (day/mo/yr) 19/12/2014 TOV Rheinland PTL. LLC. 2210 South Ronsevell Street, Tempe, Arizona 85282. Tel (480) 960.1700. Fax (775) 314-6458 1 ,r t 1