HomeMy WebLinkAboutB15-2695MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Butte County UTILITY: Pacific Gas and Electric Company CONFIDENTIAL —THE INFORMATION HEREIN ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. -THIS SYSTEM IS GRID—INTERIIED VIA A 80 DEERWOOD DR 11.7 KW PV ARRAY PART To OTHERS TS ORGANIZATION, EXCEPT�IIN CONNECTIODE THE N (WITH AC ALTERNATING CURRENT, UL—LISTED POWER—CONDITIONING INVERTER. (45) REC # REC260PEZ BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN . EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING.. 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION,' FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE T # GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. , I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97., 250.92(B). Isc SHORT CIRCUIT CURRENT• 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR f kW KILOWATT `- ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). i MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP. TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT 3 VICINITY MAP INDEX Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 PROPERTY PLAN PV3 SITE PLAN 'PV5 PV4 STRUCTURAL VIEWS STRUCTURAL VIEWS LICENSE GENERAL NOTES PV6 UPLIFT CALCULATIONS PV7 THREE LINE DIAGRAM CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 Cutsheets Attached CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR AHJ: Butte County UTILITY: Pacific Gas and Electric Company CONFIDENTIAL —THE INFORMATION HEREIN JB -9595028 O O X06 NUMRkRRETHAFORD, PREMISE OWNER: DESCRIPTION: CONTAINED SHALL NOT BE USED FOR THE ALLEN RETHAFORD RESIDENCE MOUNTING SYSTEM: Comp Mount Type C BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHALE OR IN 80 DEERWOOD DR 11.7 KW PV ARRAY PART To OTHERS TS ORGANIZATION, EXCEPT�IIN CONNECTIODE THE N (WITH OROVILLE, CA 95966 MODULES: ,THE SALE AND USE OF THE RESPECTIVE (45) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PAGE NAME: (530) 310-0935 COVER SHEET INVERTER ABB PVI-4.2—OUTD—S—US—Z—A REV BY DATE COMMENTS REV A NAME DATE COMMENTS * * * * * * * * * * * * DESIGN: Dayana Hijaz SHEET: REV: DATE:- PV ATEPV 1 10/29/2015 ,WA,SolarCity. 3055 ClearAew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (886)—SOL—CITY (765-2489) www.solarcRy.com 6 mowv�.r 8 I I I I 94'-3" I 1 1 I 1 mg A , mftm, vid . ■ PROPERTY PLAN ' APN:079100008000 Scale: i" = 20'-0' 0 20' 40' F s CONFIDENTIAL — THE INFORMATION HEREIN ,aB Nr4m UMBER JB -9595028 O O PREMISE OWNER DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THERETHAFORD, ALLEN RETHAFORD RESIDENCE Dayana HijazBENSO�a�C�t NORESHALL ITBEDISCLOSED N WHOLE ORComp Mount Type C EXCEPT SOLARCITY CIN MouNTING Sym- NOR YSIl]I 80 DEERWOOD DR 11.7 KW PV ARRAY 1, y REC PART TO OTHERS OUTSIDE THE CONNECTION VAT MODULES: OROVILLE CA 95966 ORGANIZATION, EXCEPT IN CONNECTION WITH � - . THE SALE AND USE OF THE RESPECTIVE (45) REC # REC260PEZ 3055 axle. Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTLN INVERTER PAGE NAME'REVDAA T:(650) 838-102on 8 CA (650) 838-1029 PERMISSION OF soLARgTY INC. ABB PVI-4.2—OUTD—S—LLS—Z—A (530) 310-0935 PROPERTY PLAN PV 2 10/29/2015 (BBB)—soL—CITY (765-2489) www.solarcLy.com PITCH: 33 ARRAY PITCH: 33 MP1 AZIMUTH: 56 ARRAY AZIMUTH: 56 MATERIAL: Comp Shingle STORY: 1 Story PITCH: 33 ARRAY PITCH: 33 MP2 AZIMUTH: 236 ARRAY AZIMUTH: 236 _ MATERIAL: Comp Shingle STORY. 1 Story Y • QM Inv Inv• � � . — — 3' FSB 3' FSB — — 03 I o y (E) DRIVEWAY I ---� —{--3'FS13CD I co /. 0 (A i 1 1 0 LEGEND ` 3 ® Q (E) UTILITY METER & WARNING LABEL C � m "11 INVERTER W/ INTEGRATED DC DISCO Front Of House cn 00 "' B Inv &WARNING LABELS DC I DC DISCONNECT & WARNING LABELS O I -to– – STRUCTURE CHANGE ac AC DISCONNECT & WARNING LABELS go 11 1 Q DC JUNCTION/COMBINER BOX & LABELS CHANGE I QD DISTRIBUTION PANEL &LABELS I � go Lc LOAD CENTER & WARNING LABELS m/9A 3 O DEDICATED PV SYSTEM METER 3' FSB rt N L — — — — 3' FSB — — Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — GATE/FENCE Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED L'= J SITE PLAN Scale: 3/32" = 1' 01' 10' 21' F d WEIR s CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER JB -9595028 O 0 PREMISE OWNER RETHAFORD, ALLEN DESMPTION: RETHAFORD RESIDENCE DESIGN: Da ana Hi az y 1 \�` -ootr • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN MOUNTING SYSTEM: Comp Mount Type C 80 DEERWOOD DR 11.7 KW PV ARRAY �w SolarCity h� PART TO OTHERS OUTSIDE ON RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES OROVILLE, CA 95966 THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN (45) REC # REC260PEZ PAGE NAME SHEET: REV: DATE 3055 aearview Way San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER ABB PVI-4.2–OUTD–S–US–Z–A - • • (530 310-0935 \ ) SITE PLAN PV 3 10/29/2015 638-1028 F:(650) _ (MB) (SOL)CITY ((765-2489) www.solarcity.com PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER B SIDE VIEW OF MP1B NTS � . , , . MP1B X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" PORTRAIT 1 48" 20" TOP CHORD 2x4 @ 24" OC ROOF AZI 56 PITCH 33 STORIES: 1 ARRAY AZI 56 PITCH 33 t . BOT CHORD 2X4 @24" OC COMD Shingle ~ INSTALLATION ORDER LOCATE RAFTER, MARK HOLE. (1) LOCATION, AND DRILL PILOT HOLE. (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. r (3) INSERT FLASHING. (4) PLACE MOUNT. , � (5) INSTALL�LAGOLT WITHSEASHER. SUBSEQUENT MODULES STALL LEVELING FOOT WITH C(6)FBOLT & WASHERS. S1 STANDOFF � ; SIDE VIEW OF MP1A NTS �A MP1A X -SPACING X -CANTILEVER Y -SPACING Y-CANTILEVERI NOTES LANDSCAPE 72" 24" 72" 24" "46%CONTAINED h� SolarCity. PORTRAIT 48" 20" RAFTER C.J. TOP CHORD 2X4 @ 24" OC BOT CHORD 2X4 @24" OC ROOF AZI 56 PITCH 33 STORIES: 1 ARRAY AZI 56 PITCH 33 Comp Shingle CC)�Sl�DE VIEW OF MP2A NTS (E) 2x4 MP2A X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24" "46%CONTAINED h� SolarCity. PORTRAIT 48"20" RAFTER C.J. 11 2X4 @ 24 OC 2x4 @24" CIC ROOF AZI 236 PITCH 33 ARRAY AZI 236 PITCH 33 STORIES: 1 Comp Shingle CONFIDENTIAL – THE INFORMATION HEREIN SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN NOR PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTQJ PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9595028 - OO PREMISE OWNER: DESCRIPTION: RETHAFORD, ALLEN RETHAFORD RESIDENCE 80 DEERWOOD DR 11.7 KW PV ARRAY C OROVILLE , CA 95966 PAGE NAME 530 310-0935 + ) STRUCTURAL VIEWSc DESIGN: Dayana Hijaz "46%CONTAINED h� SolarCity. MOUNTING SYSTEM: Comp Mount Type C MoOULEs (45) REC # REC260PEZ 3055 CleaNew Way San Mateo, CA 94402 O 638-1028 F:(650) 638-102 (868)—SOL—CITY cT65-2489) www.solarcity.com SHEET: REV: DATE ,_ PV 4 10/29/2015 INVERTER: ABB PVI-4.2—OUTD—S—US—Z—A S1 R —4 (E) LBW D ' SIDE VIEW OF MP2B ►is,+ .r - v" MP2B X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24". PORTRAIT 48" 20" - TOP CHORD 2X4 @ 24" OC ROOF AZI 236 PITCH 33 STORIES: 1 ARRAY AZI 236 PITCH 33 L ,� BOT CHORD 2x4 @24 OC Com p Shingle y . i - 4. • fes: f CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER JB -9595028 00 . PREMISE OWNER: RETHAFORD, ALLEN DESCRIPTION: RETHAFORD RESIDENCE DESIGN: Dayana Hijaz solarCit BENEFIT OF Q SHALL IT BEE EXCEPT SOLARCITY DISCLOSED IN VMOLE ORCIN MOUNTING SYSTEM: Comp Mount Type C ou 13055 80 DEERWOOD DR � 11.7 KW PV ARRAY 'o . y PART TO OTHERS THE RECIPTS MODULES: MODULES: OROVILLE, CA 95966 ,` y ORGANIZATION, EXCEPTIDE IIN CONN THE SALE AND USE OF THE RESPECTIVE (45) REC # REC260PEZ �' aearvie� way San Moteo. CA 94402 SHEET: REV DATE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INVERTER ABB PVI-4.2—OUTD—S—US—Z—A 530 310-0935 ) PAGE NAME STRUCTURAL VIEWS ,.PV 5 10/29/2015 (888)—SOL—CITY(765-2489) w:�►�t�iycom UPLIFT CALCULATIONS `_ 10.27.2015 P 11 ' System ,Structural Version #52:6 =SolarCn�t s Desian Software P ,_ eo Infonmation & Table Of ;Contents Rlsk•Category PV_� ystem Type II SolarCity Sleekount'"'� Comp Roof Comp Roof Roof Slope 330 Raft Sb adn b29"�OG� PV", em Module. Orientation Lands cape.and Portrait: PU; Module Area Y, :799isf " — - --- -- PV Module Width 39" P,�V Module Length 'i illi Standoff:(Attachment'Hardware Com MOunt'.T ' e C; Reduced;Ground/Roof'Live%SAb* Loads Ground Snow Load . 0.0 psf ASCE Table 7-1 _Su" , ro riding Roof_Snow_____ Roof Snow M&.113V Modules '�pg� Oa p f CE 'Eq_ 7.41 0.0 ASEE E : 7,4,1 Wind Desi n. Griteiar. Wiinnd.Design Code ASCE 7-10 nd;Desyn Methods Basic Wind Speed ' F�cposure Catan v' ...,� - r Partially/FullyEnclosed MethoG V 1.10 mph C Fig.=26:5=IA, Se< on 26: Roof Style' Gable.Roof R93o;4-zA/B/C- gM ;___ MeanRoof Height_ z''CSe tion 26 Effeitive Wind Ar]Module A ;17:8 sf: I13C 1509.7:1 Wind P&tiUib1C1A1 &3tian Coef_ ficienfs' "' Wind Pressure Exposure KY 0.85 Table 30 3-1 Too hic Factor-,.Kzf 3:00Sc4on26-'8 Wind Directionality Factor Kd 0.85, Sedion.26.6;1 :Imo cttr`_ I Velocity. Pressure qh- qh'=,0.00256 (Kz) (Kit) (Kd) (V^2) :4 22: sf Equation'30 3-1 Ext. Pressure CoefHdernt:(Up) E _ es u er C of denti Down j GCp (Up) G Z'Down ,0;88 0.95' FC9:30:42A/8JC5AJB ' Fig; 3 s/e; Desi n Wind Pressure .= h G E `nation 30 4=1 3WHA-Prewure up — ._ .: PC P_)..,..e,- =21:2 psf;" Wind Pressure Down' down 19.6 pd Allowable Stand'aif°S cin s, X761rection Y-Rlreetlon. Max Allowable Standoff Spadng� Landscape 72" 39"' Standoff CoriFl `uration. La'66 • e Not -Staggered' Max.StandoffTributa Area P.V Assembly Dead Load T lha, •204# W -RV 3psf Net Wind Upliffat_Sfandoff'•—' Uplift Capaoty of Standoff` �T�'�actua �' + 219Ibs T -allow 500 Ibs Standoff. Demand Ca �`�DCR 43:8%; Max Allowable Standoff Spadng Portrait `i 66" INaxvAllowatileCaidilevePartrdit� ;.20"' x Portrait Nof-Sta gered Max'Standoff Tributa Area.+ - _ Trib' 22 sf PV Assembly Dead Load VVPV 3, psf Net_Wind UqH at standoff~ T"aetua - - ,2451b UpliftCapadty of Standoff T -allow 500 lbs -- -De- 5tandoff.Demand Ca a ,. _� - ;QCR . - _ 49:10/o .r CONFIDENTIAL --THE INFORMATION HEREIN CONTAINED MALL NOT BE USED FOR THE JOB NUMBER JB -9595028 00, PREMISE OWNER RETHAFORD, ALLEN BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: -80 DEERWOOD DR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C , PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: OROVILLE; CA 95966 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (45) REC # REC260PEZ `: SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOWCITY INC. INVERTER: (530) 310=0935 ' PVI-4.2-ouTD-s-us-Z-A' UPLIFT CALCULATIONS `_ 10.27.2015 P 11 ' System ,Structural Version #52:6 =SolarCn�t s Desian Software P ,_ eo Infonmation & Table Of ;Contents Rlsk•Category PV_� ystem Type II SolarCity Sleekount'"'� Comp Roof Comp Roof Roof Slope 330 Raft Sb adn b29"�OG� PV", em Module. Orientation Lands cape.and Portrait: PU; Module Area :799isf " — - --- -- PV Module Width 39" P,�V Module Length 'i illi Standoff:(Attachment'Hardware Com MOunt'.T ' e C; Reduced;Ground/Roof'Live%SAb* Loads Ground Snow Load . 0.0 psf ASCE Table 7-1 _Su" , ro riding Roof_Snow_____ Roof Snow M&.113V Modules '�pg� Oa p f CE 'Eq_ 7.41 0.0 ASEE E : 7,4,1 Wind Desi n. Griteiar. Wiinnd.Design Code ASCE 7-10 nd;Desyn Methods Basic Wind Speed ' F�cposure Catan v' ...,� - r Partially/FullyEnclosed MethoG V 1.10 mph C Fig.=26:5=IA, Se< on 26: Roof Style' Gable.Roof R93o;4-zA/B/C- gM ;___ MeanRoof Height_ z''CSe tion 26 Effeitive Wind Ar]Module A ;17:8 sf: I13C 1509.7:1 Wind P&tiUib1C1A1 &3tian Coef_ ficienfs' "' Wind Pressure Exposure KY 0.85 Table 30 3-1 Too hic Factor-,.Kzf 3:00Sc4on26-'8 Wind Directionality Factor Kd 0.85, Sedion.26.6;1 :Imo cttr`_ I Velocity. Pressure qh- qh'=,0.00256 (Kz) (Kit) (Kd) (V^2) :4 22: sf Equation'30 3-1 Ext. Pressure CoefHdernt:(Up) E _ es u er C of denti Down j GCp (Up) G Z'Down ,0;88 0.95' FC9:30:42A/8JC5AJB ' Fig; 3 s/e; Desi n Wind Pressure .= h G E `nation 30 4=1 3WHA-Prewure up — ._ .: PC P_)..,..e,- =21:2 psf;" Wind Pressure Down' down 19.6 pd Allowable Stand'aif°S cin s, X761rection Y-Rlreetlon. Max Allowable Standoff Spadng� Landscape 72" 39"' Standoff CoriFl `uration. La'66 • e Not -Staggered' Max.StandoffTributa Area P.V Assembly Dead Load T lha, •204# W -RV 3psf Net Wind Upliffat_Sfandoff'•—' Uplift Capaoty of Standoff` �T�'�actua �' + 219Ibs T -allow 500 Ibs Standoff. Demand Ca �`�DCR 43:8%; Max Allowable Standoff Spadng Portrait 48" 66" INaxvAllowatileCaidilevePartrdit� ;.20"' Standoff Confi uration Portrait Nof-Sta gered Max'Standoff Tributa Area.+ - _ Trib' 22 sf PV Assembly Dead Load VVPV 3, psf Net_Wind UqH at standoff~ T"aetua - - ,2451b UpliftCapadty of Standoff T -allow 500 lbs -- -De- 5tandoff.Demand Ca a ,. _� - ;QCR . - _ 49:10/o .r DESCRIPTION: RETHAFORD RESIDENCE 11.7 KW PV ARRAY PAGE NAME:- UPLIFT AMEUPLIFT CALCULATIONS vDayono Hijoz=';;SolarCit . y 3055 CleaMew Way SHEET: REV: DATE San Mate% CA 94402 T:(650) 638-1028 F:(650) 638-1029 PV 6 10/29/2015 (888)—SOL—CITY (765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD Panel Number: TSM1610CFCU Meter Number: Inv 1: DC Ungrounded Inv 2: DC Ungrounded INV 1 -(1 )ABB /PVI—a.2—DUTD—S—. 24OV, EL q -(45)REC # REC26060 CA 888104 # AT PANEL WITH IRREVERSIBLE CRIMP 107548265 FCi Inverter, Zigbee 4200w, 240V, 9v� PV Module; 260W, 236.6W PTC' MC4, 40mm, Black Frame, ZEP Enabled C-10 Overhead Service Entrance _ Downsizing Main Breaker For Tie -In INV 2 -(1)ABB 1 PVI-4.2-OUTD-S-US-Z-A EL• B FCI Inverter, Zigbee 420OW, 240V, s Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER �E 125A MAIN SERVICE PANEL N� 100A/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! SolarCity Inverter 1 IND ❑A ( 1)100A/2P 9 ABB A 6 I Vstart - 200V DC+ PVI-4.2-OUTD-S-US-Z-A DG MP 1: 1x11 (E) LOADS L1zaev-.----- - - - — - ----- - - - - - EGc -------- - - -------------tpj • L2 pC+ I 25A/2P ' EGG. '.. DC+ DC+ Vstart= 2OOV A r-- ------- --__---=---------- ,• , — — — — — — — — — — -- — — - — — — -- —G---lN DC- -CC C MP 1 1x11 I .' _IN .EGC--- ——— — -- — —— ------------ — —----- -- �———— ———————— — ----J N 3' ADJUST MIN. ACTIVATION VOLTAGES! (1 )Conduit Kit; 3/4• EMT • J o EGC/GEC Inverter 2 IND — GEC ABB 8 3 DC+ Vstart = 200V Z PVI 42 OU SUSZA TD MP 2.112 25A/2P ecc .J A L, �4e�--------- ------------ -------- - - ----------- - - - - - B 1 TO 120/240V N I I � L2 DC+ N DG I 7 4DC+ SINGLE PHASE ----- I ------ ----------------------------- EGG DC+ = —GEC' ---lN Vstart = 2OOV UTILITY SERVICE DG - C X 1-1 11 tpj .. _ GND __ EGC---——— — - — — —— ------------ — — ----- -- GC -__-_MP — — — — }r, (1)Conduit. Kit; 3/4' EMT' Voc* = MAX VOC AT MIN TEMP POI (1)GE # THOL2125 PV BACKFEED BREAKER Breaker, 25A/2P, 2 Spaces �� Q ^ (1)SdarCitY 4 STRING JUNCTION BOX D� 2x2 SiRGS, UNFUSED, GROUNDED — (1 )GE # THQL2125 PV BACKFEED BREAKER Breaker, 25A/2P, 2 Spaces — (1 )Gro qd Roo 58 x 8, Copper — (6)GE # THOP120 To thin the 20A/1P 1 space Breaker, 20A/1P, 1/2 Space 1 AWG #10, THWN-2, Black (1)AWG 110, THWN-2, Red O (1)AWG j10. THWN-2, Block Voc* = 456.22 VDC Isc = 9.01 O (1) AWG 110, THWN-2, Red Vmp = 337.7 VDC Imp= 8.5 ADC ADC 2) AWG #10, PV Wire, 60OV, Block O (1)AWG #10, Solid Bare Copper EGC VoC* = 456.22 VDC Isc = 9.01 ADC Vmp = 337.7 VDC Imp= 8.5 ADC LhL LLLL (I )AWG #10, THWM-2, White NEUTRAL Vmp =240 VAC Imp=20 AAC (1 AWG �1°, HHN/THWN-2, Green EGC ....... 70 AWG #8,. RWN-2,• Green • • (1 AWG 110, THWN-2, Black EGC/GEC .- (1) Conduit. Kit;, 3/4' .EMT.. , .. , ... • • , , , (1 AWG 110, THWN-2, Black Voc* = 456.22 VDC © (1) AWG 110, THWN-2, Red Vmp = 337.7 VDC Isc ='9.01 Imp= 8.5 ADC ADC (2) AWG #10, PV Wire, 60OV, 66ck O (1)AWG 110, Solid Bare Copper EGC Voc* = 456.22 VDC Isc = 9.01 ADC Vmp = 337.7 VDC Imp= 8.5 ADC ®� _ (1) 4WG,110, THWN-2, Red (1) AWG 110, 1}iHN/T...... Green EGC '.. (1)AWG #10, THWN-2, White - (1) AWG 18,• TFLWN-2,. Green NEUTRAL Vmp =240 VAC Imp= 20 EGC/GEC - (1)Condgit. Kit; 3/47. EM AAC .. ... .............. . (1)AWG 110,. THWN-2, Block Voc* = 456.22 VDC CA = 337.7 VDC O (1)AWG j10, THWN-2, Red Vmp Isc = 9.01 Imp= 8.5. ADC ADC (2 )AWG 0D. PV Wire, 60OV, Block O (1)AWG 110, Solid Bare Copper EGC Voc* = 497.69 VDC Isc ='4.61 ADC Vmp = 368.4 VDC Imp= 8.5 ADC • ..._ .. , . • .., , • ... . ..... III.. LLL. (1 AWG 110, THHN/THWN-2,. Green. EGC ®� (1 AWG 110, THWN-2, Black Voc* = 497.69 VDC (1) AWG 110, THWN-2, Red Vmp = 368.4 VDC Isc = 9.01 Imp= 8.5 ADC ADC (2) AWG 110, PV Wire, 60OV, Black ® (1)AWG 110, Solid Bare Copper EGC Voc* = 456.22 VDC Isc = 9.01 ADC Vmp = 337.7 VDC Imp= 8.5 ADC ��I LLL CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB' 9595028 0 0 PREMISE OWNER. D�,PnOl. DESIGN: \\� CONTAINED SHALL NOT BE USED FOR THERETHAFORD, ALLEN RETHAFORD RESIDENCE Dayana Hi'az J MOUNTING SYSTEM: Comp Mount Type C BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN $0 DEERWOOD DR 11.7 KW PV ARRAY AA.,SolarCity. PART TO OTHERS OUTSIDE THE RECIPIENTS OROVILLE CA 95966 MODULES: 3055 CleaMer way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (45) REC # REC260PEZ , - REV: DATE [��v7 10/29/2015 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. Z Z PAGE NAME 530 31 0-0935 �) THREE LINE DIAGRAM San Mateo, CA 94402 (888)-SSOL-CITY (029 7°65-2489j50mmsolrcitycamABB INVERTER: PVI-4.2—OUTD—S—US—Z—A A • POWERPHOTOVOLTAIC Label Location: Label Location: !a` Label Locations SOURCE (C)(IC)(CB) z (AC). _ WA • (DC)(INV)(CB)PV SYSTEM Per Code . • FOR ` f �• a _ Per Code: ELECTSHOCK CRC R331.2 OPERATION r "? - THE DC CONDUCTORS OF THIS CEC 690.35(F) j' Label Location: k �.-, u, w � • • • TO BE, WHEN - - x PH • • • (DC) (INV)t ..' _ ,�s- -•. . . INVERTER IS ' '•' • Per Code: , r �. - , UNGROUNDED'"' CEC 690.14.C.2 , `a Label Location:" - WARNING J Per Code: .ELECTRIC SHOCK HAZARD CEC 690.17 Label Location' .• •• MAXIMUM -• (DC) (INV). - • :• .' �t •_�� . -' Per Code. LOAD SIDES MAY BE ENERGIZED . t .OIN THE OPEN POSITION MAXIMUM -�GE ITip) CEC 690.53. .t, s - ; ,. ,. VOLTAGEMAXIMUM SYSTEM • '} r,A . .' - q +' .rte, •r �e r SHORT-CIRCUIT=5 * • err nC'. .j,:. 'a 4i 4� .� at�H. ♦ - r„ - Y - -•`F ,.-+ •- ,* Z ; , ` "J""Label Location:`„'• WARNING (POI) . a ,4- : t Per Code:' M• , ” ' .. i *._. w - -- , • CEC 705.12.D.7CONNECTION '.•, _ :' ;f ` Label Location: `` . • NOT RELOCATEDEVICE THIS OVERCURRENT WARNING - Per Code.ELECTRICAL SHOCK HAZA�;�, .�„71 . • NOT TOUCHCEC 690 17 K .,1 J - TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED 4." IN THE OPEN POSITION '.Label Locations VOLTAGEDC PHOTOVOLTAIC- • • (POI) iy • {.' n'� •- r _ i `.''� '- .,aJ`�' • + * - �^ ALWAYS PRESENT WHEN. • Per Code: .. + WARNING: ELECTRIC SHOCK EXPOSED . -.. • • • CEC 690.54; CEC 690:17HAZA.- TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label Location: DE-ENERGIZEDE-ENERGIZE BOTH SOURCEAND ; ��' • . " ; �' - t WARNING(INV) PV POWER •IN Per Code: MAXIMUM AC ROUELECTND . FAULT ISINDICATED _-. CEC 690.5(q) - •• MAXIMUM AC NORMALLY GROUNDED OPERATING VOLTAGE CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: .� R Label Location`. -CAUTION(D) (POI)`+ PHOTOVOLTAIC (AC) (POI) Per Code: x (AC): AC Disconnect _ Per Code. PHOTOVOLTAIC r.; DISCONNECT. CEC 690.64.B.4 f, (C): Conduit CEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: Label Location w , (AC) (POI) - • (POI) . „ (INV): Inverter With Integrated DC Disconnect MAXIMUM AC• `. (LC): Load Center '' Per Code: • - • - • Per Code: ��, r - ` (M): Utility Meter MAXIMUM AC CEC 690.54 ' ' CEC 705.12.D.7 - a • P •PHOTOVOLTAIC" • 4 (POI): Point of Interconnection ,.,� �. CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR ► t �� Rr�R 3055 aearview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED _ . + �► San Mateo, CA 94402 IN WHOLE OR 1N PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set T:(650) 638-1028 F:(650) 638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ' _ it a (888)-SOL{[1Y (765-2489) www.solardty.com S01 [Cit 4 .7 _ Zep System for composition shingle roofs':. , a ` r -4 • . .. l - - 1. ~. ' t t ��� � .e, , ,r .� � j .. ® - .4 ' � � _tom e � ' • �'�• ' , Y - - ,. %, f• Y' ",SolarCitYI ZepSolar Next -Level PV Mounting Technolosy . 'ISolarCity� Z pSolar `Next -Level PV Mounting Technology _ , _ Zep System for composition shingle roofs':. , a ` r -4 t t 41 F Description •O• s 1 t �' ' • PV mounting solution for composition shingle roofs ~�Acanlps,, r Works with all Zep Compatible Modules 'a ' • . •' —Auto bonding UL` -listed hardware creates structual and electrical bond r a • + s Zep System has a UL 1703 Class "A" Fire Rating when installed using USTED modules from any manufacturer certified as "Type 1" or'Type 2" 1 Comp Mount Interlock Leveling Foot ._ '!• Part No. 850-1382 Part No. 850-1388 Part No. 850-1397 Listed to UL 2582 & Listed to UL 2703 Listed to UL 2703 w ^ 'r Mounting Block to UL 2703 ' • Specifications 9 f •t, ._ Designed for pitched roofs �,'" ' r ' Installs in portrait and landscape orientations -1*-•• , ' 4Zep System supports module wind uplift and snow load pressures to 50 psf per UL 1703 • Wind tunnel report to ASCE 7-05 and 7-10 standards Zep System grounding, products are UL listed to UL 2703 and ETL listed to UL 467' Zep System bonding products are UL listed to UL 2703 , Engineered for spans up to 72" and cantilevers up to 24" , s _ • 1 Zep wire management products listed to UL 1565 for wire positioning devices , ' Ground Zep Array Skirt, Grip, End Caps DC Wire Clip _ Attachment method UL listed to UL 2582 for Wind Driven Rain ` Part No. 850-1172 r Part Nos. 500-0113, Part No. 850-1448 ' Listed to UL 2703 and 850-1421, 850-1460, Listed UL 1565 i# �;•' , T , '' ETL listed to UL 467 850-1467 1 Listed to UL 2703 zepsolar.com „ , `, zepsolar.com z • < '� • _ ' rte+ This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for `+ ""' This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the,product warranty. The customer is solely '_ ., each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. -.+ 3 responsible for verifying the suitability of Zep Solar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. , { 02 2715 ZS for Comp Shingle Cutsheet Rev 04.pdf . Page: 1 of 2 }•+ 02 2715•ZS for Comp Shingle Cutsheet Rev 04.pdf, , Page: 2 Of 2 a ' Additional highlights:Solar - inverters h — RS -485 communication interface` ABB inverters (for connection to laptop or data string +. r'ht —Integrated Arc Fault Detection and (• ' r 4 .' Interruption (-A Version). 4• 3.OkW to I !: y { j' i � , � � � � it • •w ; x'/: ,-'y , �• � Technical data and types •* i�� , _ . �;1 ' • n, ' ` f, c Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US ..� ... r . • I Mechanical specifications ti. • ti ♦ A'. ' ' '• - Nominal output power 3000W 3600W 30 380OW 4200W • + _ . r. ...3600..:...4000'",...4000' ...3 :: _ - , .� Maximum output power wattage..... 3000..,...3300' € 3300'. 00 4200' € 4200'..; ' 4200..: 46001 4666-v. T' , V. , , ................................................................ W W W W W _ W W W W ' W W ' W ' s Rated grid AC voltage _ 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V ; e . llnput side (DC) Number of independent MPPT channels 2 2 2 2 ?" • , • '. •h Maximum usable ower for each channel P..... 2000W 3000W 3000W , 0 W 3 00 i• - ... Absolute maximum voltage (Vmax) 600V . - . t.. ' . •. '`a",,= �.. :. ' + .. _ ., x K ` c # - ....... ..... ...... .. .... .... ... .................. Start -u voila a start P...............9.....N..........).......................................... .............._.................. ...... _ -.... ............._.................-........... .................... _.............._.................._... 200V ad'. 120-350 .......... .......... .... (.. 1..-.........- _h ^............_................. -...................-................-_.................... ......._................... ;14 , a .e .. P f ,x' Full power MPPT voltage range 160-530V _ .............................................. 120-530V 140-530V 140.530V O eratln MPPT voila a ran e P 0.7 x Vstart 580V > 90 (...._.......1......._.................._..................._..................................... .• ...............9........................9.......9............ Maximum current (ldcmax) for both MPPT in ..........._.................._............ 20A ..............._.. ... ..._....... 32A 32A : '' 32A _ .. .� ..• a • . • Parallel . .................:.............. Maximum usable current er channel € P...... .....(,........ :... 10A ............. 16A 16A .................... .......-...._..............._.............. ..............._.......... 16A .................... . ?' n . Maximum h r i... rr short circuit t cu enl limit per 12.SA 20:OA.._............. 20AA._..... .. e ry r' channel. ................................................................... ................................._20.OA... r' * ,. Number of wire landing terminals er channel i 2 airs P..................._..................._................._ • ... �` .........,.....................................P...............................':................_..................._................._. Array wiring termination _ Terminal block, pressure clamp, AWG10-AWG4 ...•....I..... _............ ._.................. . - - • r ® tr �` r"�' n - .. -.,_ k.. (Output side (AC) i i 10 r - - Grid connection type 10 Split- I 10 10T Split- i 10/ 19 Split- 10 10 Split- ................_................................................................................_2W...- ....0/3W......_2W i 2W 0/3W i 2W 2W i 0/3W i 2W i 2W i 0/3W i 2VV + Adjustable voltage range (Vmin-Vmax) M 183 - 211 - 1 244- i 183- 211- :. 244- 183- 211- 244- 183- 211- 244- , •r , ti .......... . ................. Grid frequency 228V 264V € 304V [ 228V 264V 304V 228V 264V i 304V ............................................................................................_................._..................._..................._................... 60Hz i 228V i 264V 304V . �. r . < _ 'r..# ........................................:.s..................._..................._..................._..................._..................._.................._.................._..................._................... Adjustable grid frequency..range 57. 60.SHz ...... ............. ._................... _.................... - • .............::....:.............. ................... Maximum current (I..—) ..................__....... 14.5 € 14.5 12.0 ' 17.2 ' 16.0 ' .16 .0 16.0..., 16.0 16.0 20.0 20.0 ` 20.0 r , .. p A e p A e A e A e . a..........:_•RMg.._.• Power factor > 6.995 ..................................................................................................._........_'........_..................._..................._..................._..................._..................._..................._..................._..................._..................._.................... Total harmonic distortion at rated power < 2% .... This family of single-phase string The high-speed MPPT offers real- Highlights: , ' _ ..... Grid wiring termination type ...................................................... .._ ._ Terminal block, Pressure clamp, AWG10 AWG4 ................... _................... .................... . '. inverters complements the typical time power tracking and improved, = Single phase and split phase output T . _4 7 llnput protection devices ... number of rooftop solar panels energy harvesting. gnd connection. M,: ' iJ .: , . Reverse..P.olaritY...P..rotection.................................................................._..................._..................._..................._........................:.......... _ Over-vona a rotection t pe Yes........... Varistor, 2 for each channel .......I.......................... ' - enabling home -owners to get the most •The flat efficiency curve ensures high — Wide input range for increased . .. ..................9.....P..........................Y..................................................................._..................._..................-_..................._..........................................................._......... Pv array ground fault detection .................... Pre start-up Riso and Dynamic GFDI (requires floating arrays) ' efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. loutpul protection devices' of the property. a consistent and stable performance r •" — The high speed and reclse MPPT p - ; AnU islanding rotection ................................................................................................. .......P................................ lta.9e..P..rotection.tY..P..e Meets UL 1741/IEEE1547 requirements ......._................... _isto.. Varistor,_ .............. ............_................... across the entire input voltage and algorithm offers real time power = r t. ..O...... ....................................................................................................... Maximum AC OCPD Rating 20A, ; 20Ae„� : ..4b!..:_ ./!.;_G).-..........,...................:...................,..:................,.................... 1 SA,,,� 25A,,,� 20Ao 20Aa i 20A, 20&_ ' 20A_ ; 25Ap i 25Ao 25Ao„a This inverter offers a dual input output power range. tracking and improved energy j:•.,; iEfficiency ,� . v 1 - , section that processes two strings The transformerless operation the harvesting. Maximumefficiency...................................................................._._96.9%._..................._................._ ..97%...._.......... 97%...._.................. -...................-..._97%...._................ ---- - ..--- gives CEC efficiency 96% , with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure - 10perating performance f ' Tracking (MPPT). The wide input voltage range makes for unrestricted use under any- 14,Night time consumption < 0.6w_ This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption < 8%_ installations with two different installations with reduced string size. — Integrated DC disconnect switch ,' `fir ICommunication * € User -interface ................. .................... ................... ..................... .................. 16 characters x 2 lines LCD display orientations from two sub -arrays This rugged outdoor inverter has been in compliance with international ► Remote monitoring (1xRS485 incl.), VSN700 Data Logger (opt.) oriented in different directions. (For designed to tie a completely sealed Standards (-S Version). �;: (Environmental e - r Ambient air operating temPeraturerange---. -13°F to_+140•F with derating above 122 F (SO C) ................._......... .._. example: East and West) unit able to withstand the harshest - Ambient air stora a temperature ran a 9 40 F to +176 F 40 C to +80 C) _.............. "• The dual input sections with P environmental conditions. Y� „ - F y ...........................................g...................._..................._..................._..................._ Relative humidity .. ''........................._.................._..................._._.:.._............_...-...._0.:1.00% ............................................................................................... ......._(.................-..................._.................. RH condensing _.............. .. .................... _.................... , independent MPPT enable a more + .� Acoustic noise emission level .• ........................................................... <50 db (A) ®1m + optimal energy harvesting condition. ` :.;y. t. Maximum.operating altitutde without derating.......... ...........................................6560_ft..(2000!t!)_................ ..._................... .................... _................... .................... . Power and productivity - t. Capability enabled at nominal AC voltage and with sufficient DC power available. - for better c ; •� • - . - .- _ '� - a worldT”' '.� �•:, 2 ABB Solar Inverters I Product Flyer for PVI-3.0/3.6/3.8/4.2•TL-0UTD • �- . . x, , •"i . REC PEAK ENERGY Z -LINK SERIES 55.55 ±0,1 • p EFFICIENCY r _ 1.38 39 02 YEAR LINEAR POWER REC PEAK ENERGY Z -LINK SERIES 55.55 ±0,1 • p EFFICIENCY � - _ 1.38 39 02 YEAR LINEAR POWER OUTPUT WARRANTY � _ Wim•. _ ,o IN _ - l) 0 - 47.24^ 0.47.V 16 A r — ---- - - -------._................. -- ........................ ---- ---._._._.._- • �_t J All measurements in inches - ELECTRICAL DATA @ STC Nominal Power- P.(Wp) REC260PEZ 260 Watt Class Sorting-(Wp) ./-5 Nominal Power Voltage- V(V) 30.7, Nominal Power Current- I� (A) 8.50 OpenCircuitVoltag e-Vac(V) W 37.8 Short Circuit Current- Isc (A) 9.01 Panel Efficiency (%) 15.8 w _ The electrical characteristics are within -/-10% of the indicated values of IS5rr, V. and P. at standard Test conditions 77'F (STC). Values at standard test conditions STC (airmass AM I.S. irradiance 1000 W/m', cell temperature (25'C)). - At low irradiance of 200 W/m2 (AM 1.5 & cell temperature 77°F (25'C)) at least 97% of the STC panel efficiency will be achieved. ...-: Nominal Power -. P.. WP) T. Nominal Power Volt age-V„,(V) _ 29.0 Nominal Power Current- I,,,pp(A) 6.81 Open Circuit Voltage -Vo, (V) 35'7 Short Circuit Current -1,(A) _ : 7.24 Nominal operating cell temperature NOCT (800 W/m', AM 1.5. windspeed I m/s. ambient temperature 68•F (20^C). 10 year product warranty. 25 year linear power output warranty <"`uSrEn (max. degression in performance of 0.7%p.a.). UL 1703. Fire rating: Type 1, Class C Nominal Operating Ceti Temperature(NOCT) 45.7°C(t2°C) Temperature Coefficient of P, -0.40%/°C TemperatureCoefficient ofVac -0.27%/°C Temperature Coefficient oflsc 0.024%/`C E GENERAL ,• Cell Type: 60 REC PE multi, crystalline 3 strings of 20 cells with bypass diodes . Glass: 0.125 in solar glass with anti -reflection surface treatment Back Sheet: Double layer highly resistant polyester Frame: Anodized aluminum (black) Zep Groove compatible Junction Box: IP67 rated 0.156 in (12 AWG) solar cable, 2 x 47.24 in Connectors: H4 Amphenol Origin: _ Made(ri5ingapore MAXIMUM RATINGS Operational Temperature: -40...+185•F(-40...+85°C) Maximum System Voltage: 1000 V UL Design Load_: 50 Ibs/ft2 (2400 Pa) long side 30lbs/ft2 (1436 Pa) short side Max Series Fuse Rating: 1S A Max Reverse Current: 15A MECHANICAL DATA Dimensions: 65.55x39.02x1.57in(1665x991x40rnm) d Area: t 17.751`00.65 m2) .Weight: 431bs(19.5kg) Notel All given specifications are subject to change z without notice at anytime. Ir r REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Ourl,600 employees worldwide generated revenues of USD 647 million in 2013. RCC C. www.recgroup.com p EFFICIENCY Q YEAR PRO❑UCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY Nominal Operating Ceti Temperature(NOCT) 45.7°C(t2°C) Temperature Coefficient of P, -0.40%/°C TemperatureCoefficient ofVac -0.27%/°C Temperature Coefficient oflsc 0.024%/`C E GENERAL ,• Cell Type: 60 REC PE multi, crystalline 3 strings of 20 cells with bypass diodes . Glass: 0.125 in solar glass with anti -reflection surface treatment Back Sheet: Double layer highly resistant polyester Frame: Anodized aluminum (black) Zep Groove compatible Junction Box: IP67 rated 0.156 in (12 AWG) solar cable, 2 x 47.24 in Connectors: H4 Amphenol Origin: _ Made(ri5ingapore MAXIMUM RATINGS Operational Temperature: -40...+185•F(-40...+85°C) Maximum System Voltage: 1000 V UL Design Load_: 50 Ibs/ft2 (2400 Pa) long side 30lbs/ft2 (1436 Pa) short side Max Series Fuse Rating: 1S A Max Reverse Current: 15A MECHANICAL DATA Dimensions: 65.55x39.02x1.57in(1665x991x40rnm) d Area: t 17.751`00.65 m2) .Weight: 431bs(19.5kg) Notel All given specifications are subject to change z without notice at anytime. Ir r REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Ourl,600 employees worldwide generated revenues of USD 647 million in 2013. RCC C. www.recgroup.com ' X "' SolarCity ®p$olar Next -Level PV Mounting Technology DWV Debris Guard, for composition shingle roofs 01 I 1 t. PHOTOVOLTAIC MODULE - - DWV DEBRIS GUARD ri COMP ROOF MOUNT • t ` - COMP ROOF , O • , a ' f iMr DWV Debris Guard Construction Detail Debris Guard, close up N�QpOMP4,1/ - Prevent blockages and keep vents open with the DWV Debris Guard. Protects against: ! Leaves Rain ��MPPT • Pine needles Insects ` • Snow Birds N DWV Debris Guard is made of rugged 26 gauge galvanized steel. zepsolar.com This document does not create any express warranty by Zap Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for ' each product. The end-user documentation shipped with Zap Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely - f responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. - - Document # 800-1677-001 Rev A - Date last exported: April 3, 2015 4:04 PM