HomeMy WebLinkAboutB15-2807 042-090-088COLLISION PROS INC. 2910 Highway 32 Chico, CA -' Exhaust discharge point Exhaust discharge point 10'-0" 160-4" Exhaust discharge point Exhaust discharge point Exhaust discharge point E 6'-0" �I10'-0" -'1 3'- 0" 116'-4" 8'-4" 41--U 41'-b NFPA 33 Standard for Spray Application Using Flammable or Combustible Materials. 2011 Edition 2011 Edition NFPA 33 Standard for Spray Application Using Flammable or Combustible Materials Chapter 5 Construction and Design of Spray Areas, Spray Rooms, and Spray Booths 5.1.2 The floor of the spray area shall be constructed on noncombustible material, limited -combustible material, or combustible material that is completely covered by noncombustible material. 5.1.4 If walls or ceiling assemblies are constructed of sheet metal, single -skin assemblies shall be no thinner than 1.2mm (0.0478 in.) and each sheet of double -skin assemblies shall be no thinner than 0.9mm (0.0359 in.). 5.1.5 Structural sections of spray booths shall be permitted to be sealed with a caulk or sealant to minimize air leakage. 5.1.6 Spray rooms shall be constructed of and separated from surrounding areas of the building by construction assemblies that have a fire resistance rating of 1 hour. 5.1.7 Enclosed spray booth and spray rooms shall be provided with means of egress that meet the requirements of NFPA 101, Life Safety Code. 5.1.8 Spray booths that are used exclusively for power coating shall meet the requirements of Chapter 15. They shall be permitted to be constructed of fire -retardant combustible materials where approved by the authority having jurisdiction. Exception: Listed spray booth assemblies that constructed of other materials shall be permitted. 5.3 Separation from Other Operations. Spray booth shall be separated from other opertions by a minimum distance of 915mm (3 ft) or by a partition, wall, or floor/ceiling assembly having a minimum fire resistance rating of 1 hour. Multiple connected spray booths shall not be considered as "other operations" except as provided for in Section 13.3. 5.3.1 Spray booths shall be installed so that all parts of the booth are readily accessible for cleaning. 5.3.2 A clear space of not less than 915mm (3 ft) shall be maintained on all sides and above the spray booth. This clear space shall be kept free of any storage or combustible construction. Exception No. 1: This requirement shall not prohibit locating a spray booth closer than 915mm (3 ft) to or directly againt an interior partition, wall, or floor/ceiling assembly that has a fire reistance rating of not less than 1 hour, provided the spray booth can be maintained and cleaned. Exception No. 2: This requirement shall not prohibit locating a spray booth closer than 915mm (3 ft) to an exterior wall or roof assembly provided the wall or roof is constructed of non- combustible material and provided the booth can be maintained and cleaned. 5.5 Vision and Observation Panels. As to 2013 CFC Section 2404.3.2.6 Size: The aggregate area of spray booths in a building shall not excceed the lesser of 10 percent of the area of any floor pf building or the basic area allowed for a Group H-2 occupancy without area increases, as set forth in the International Building Code. The area of an individual spray booth in a building shall not exceed the lesser of the aggregate size limit or 1,500 square feet (139m ) Exception: One individual booth not exceeding 500 square feet (46m As to 2013 CFC: 2404.3.1.1 Floor. Combustible floor construction in spray rooms shall be covered by approved, noncombustile, nonsparking material, except where combustible coverings, including but not limited to thin paper or plastic and strippable coatings, are utilzed over noncombustible materials to facilitate cleaning operations in spray rooms. GENERAL NOTES I 1. AFC SPRAY BOOTHS ARE CONSTRUCTED OF MATERIALS CONFORMING TO NFPA 33, CHAPTER 3, SECTION 3-1 AND SECTION 3-1.1. 2. AFC SPRAY BOOTHS SHALL BE SEALED WITH MATERIALS AS PER NFPA 33, CHAPTER 3, SECTION 3-1.2. 3. WHEN INSTALLED, AFC SPRAY BOOTHS SHALL BE SEPARATED FROM SURROUNDING AREA AS PER NFPA 33, CHAPTER 3, SECTION 3-1.3 AND SECTION 3-3. ! 4. ALL OBSERVATION GLASSES & GLASSES FOR LIGHT FIXTURES ARE TEMPERED Exhaust discharge point SAFETY GLASS THAT CONFORM TO NFPA 33, CHAPTER 3, SECTION 3-5. 5. VENTILATION OF ALL AFC SPRAY BOOTHS SHALL CONFORMS TO NFPA 33, _ SECTION 3-6, SECTION 3-6.1 THROUGH SECTION 3-6.5. Up -flow canopy damper weather cap THE INSTALLED SPRAY BOOTH SHALL MEET THE REQUIREMENT OF THE 2013 it Pre -filter intake air tower CALIFORNIA BUILDING CODE, CALIFORNIA MECHANICAL CODE. CALIFORNIA PLUMBING CODE AND CALIFORNIA FIRE CODE, THE 2013 CALIFORNIA ENERGY CODE AND THE ! 25.5" DIAMETER EXHAUST STACK 2013 CALIFORNIA ELECTRICAL CODE. l 34" Diameter Stackring� Rainguard Rainguard 4 34" Diameter Stack Section Roof Flashing Roof Flashing ------------------, I , I E j I 1 I �-1 Ill I I I 1f 45' 34 diameter Elbow y , � I I _----. T .... ....._.... __ _ __ _ __� ._._ '--__-__ I ._ _._. ___........_................ ... ......... ...._.... _.... _..___.___......_...._.. .... .___....__ 45' 34 diameter Elbow 31 --- - _- -- } -- yY _ I I __ _ / , 1 I I II I 1 ��� i•; , I;I i ' I 28'-0" _ 281-4$' loc ted ting re gg� = SZOE 1,-Zoily,�- i I DECLARATION OF COMPLIANCE: THE PAINT SPRAY BOOTH MANUFACTURED BY AFC, INC., ARE DESIGNED FOR CODE APPROVAL. EACH BOOTH IS FABRICATED FROM 18 GAGE GALVANIZED STEEL, THROUGHOUT, TO EXTEND NORMAL LIFE EXPECTANCY BY FIVE TIMES. THE GALVANIZED CLASSIFICATION OF G-90 ZINC RATING IS 1.25 OUNCES PER SQUARE FOOT. ASTM A527LFQ. ALL MODELS ARE MANUFACTURED TO THE STANDARDS OF THE NATIONAL BOARD OF FIRE UNDERWITERS FOR SPRAY BOOTHS, AS RECOMMENDED BY THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA 33, 2011 EDITION), OCCUPATION SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS, INTERNATIONAL FIRE CODE (IFC 2012), CHAPTER 24 FLAMMABLE FINISHES, AND ENVIRONMENTAL PROECTION AGENCY (EPA) REQUIREMENTS. STANDARD COMPONENTS AND ACCESSORIES ARE AVAILABLE TO COMPLY WITH ANY SPECIAL STATE OR LOCAL CODE REQUIREMENTS. EXHAUST AND MAKE-UP AIR FAN: THIS FAN IS EQUIPPED WITH A NON -SPARKING BLADE THAT IS DRIVEN BY BELTS ENCLOSED IN A STEEL CYLINDER. THIS LOCATION OF THE BELTS PROVIDES MAXIMUM PROTECTION FROM THE AIR STREAM.THE ELECTRIC MOTOR IS LOCATED OUTSIDE OF THE FANS 16 GAUGE STEEL LINER SO THAT MOTOR IS NOT EXPOSED TO FLAMMMABLE VAPOR. ON CROSSFLO BOOTH THE AIR VELOCITY HAS A MINIMUM OF 100 LFPA (LINEAR FEET PER MINUTE.) AND ON SIDE DOWN DRAFTS, DOWNFLO MODELS THE AIR FLOW IS A MINIMUM OF 25% OF THE LOWER FLAMMABLE LIMIT. ELECTRIC MOTOR: THE MOTOR CONFORMS TO NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION (NEVA) RATINGS, CLASS A OR B INSULATED. MOST GOVERNMENT AND INDUSTRY MOTOR STANDARDS ARE BASED ON NEMA). ALSO , REFERNCE UNDERWRITERS LABORATORIES (UL) LISTING E, 57948 DAYTON ELECTRIC MOTORS. LIGHTS: THE LIGHTS ARE UL APPROVED (21209) AND ARE MOUNTED AND SERVICED FROM OUTSIDE OF THE BOOTH. WINDOWS ARE .250" TEMPERED GLASS, SEALED FROM THE INSIDE TO INSURE A VAPOR PROOF SEAL. THE SAME APPROVED LIGHTING FIXTURE IS AVAILABLE IN AN ARRANGEMENT THAT MAY BE SERVICED FROM THE INTERIOR OF THE BOOTH AND MAINTAIN THE VAPOR PROOF CHARACTERISTIC. VALVES: IMAGNETIC AIR VALVES ARE NEMA TYPE 1 WITH ENCLOSED SOLENOID. INTERLOCK CONFORMS TO IFC SECTION 1504.6.1.2.1 INTERLOCKS: PREVENTS OPERATION IF MAN ACCESS DOOR OR DRIVE-IN DOORS ARE OPENED LIMIT SWITCH WILL STOP THE EXHAUST FAN MOTOR AND THE PAINTERS AIR VALVE FROM OPERATING AND S 20 0° F 93°C . IF EXCEEDS ONS ) OPERATIONS PREVENTS ALL OPE THIS BOOTH IS LISTED UNDER ETL # 53993. s to 2013 CFC: 2404.3.2.1 Construction. ,ray booths shall be constructed of approved noncombustible materials. Aluminum shall not be used. Where wall or ceiling ,semblies are constructed of sheet metal, single -skin assemblies shall be no thinner than 0.0478 inch (18 gage) (1.2mm) id each sheet of double -skin assemblies shall be no thinner than 0.0359 inch (20 gage) (0.9mm). Structural sections of ,ray booths allowed to be sealed with latex -based or similar caulks and sealants. ,s to 2013 CFC: 2404.3.2.4 Means of egress eons of egress shall be provided in accordance with Chapter 10. Kception: Means of egress doors from premanfactured spray booths shall not be less than 30 inches (762mm) in width by 0 inches (2032mm) in height. Access: An a roved fire apparatus access road not less than 20 feet wide shall be provided for access within 5.5.1 Panels for lights fixtures or for observation shall be of heat-treated glass, laminated glass, wired glass, or hammered wired glass and shall be sealed to cofine vapors, mists, residues, dusts, and deposits to the spray area. Exception: Listed spray booth assemblies that have vision panels constructed of other materials shall be permitted. 5.5.2 Panels for light fixtures shall be separated from the fixture to prevent the surface temperature of the panel from exceeding 93°C (200°F). 5.5.3 The panel frame and method of attachment shall be designed to not fail under fire exposure before the vision panel fails. 5.5.4 Observation panels for spray booths that are used exclusively for powder coating processes shall be permitted to be constructed of fire-resistant combusible materials. 5.6 Ventilation. Spray areas that are equipped with ventilation distribution or baffle plates or with dry overspray collection filters shall meet the requirements of 5.6.1. through 5.6.5. 5.6.1 Distribution plates or baffles shall be constructed of noncombusible materials and shall be readily removable or accessible for cleaning on both sides. 5.6.2 Filters shall not be used when applying materials known to be highly susceptible to spontaneous heating or spontaneous ignition. 5.6.3 Supports and holder for filters shall be constructed of noncombusible materials. 5.6.4 Overspray collection filters shall be readily removable or accessible for cleaning or replacement. 5.6.5 Filters shall not be alternated used for different types of coating materials if the combination of materials might result in spontaneous heating or ignition. (See also Section 10.9.) 2011 Edition NFPA 33 Standard for Spray Application Using Flammable or Combustible Materials Chapter 6 Electrical and Other Sources of Ignition: 6.3.1.2 Class 1, Division 2 Locations. As defined in 500.5(B) (2) of NFPA 70, National Electrical Code, a Class 1, Division 2 location shall be any location where one the following conditions exists: (1) A flammable gas or volatile flammable liquid is handled, processed, or used but any flammable gas, vapor or liquid is confined within a closed container or a closed system from which it can escape only in case of accidental rupture or breakdown of the container or system or in case of abnormal operation of the equipment. (2) An ignitible concentration of flammable gas or vapor is normally prevented by positive mech- anical ventilation but might exit because of failure or abnormal operation of the ventilating equip- ment. (3) An ignitible concentration of flammable gas or vapor might occasionally be transmitted from an adjacent Class 1, Divison 1 location, unless such transmission is prevented by positive pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided. As to 2013 CFC: 2404.6.2.1 Glass panels Panels for luminaires or for observation shall be heat-treated glass, wired glass or observation shall be heat-treated glass, wired glass or hammered wire glass and shall be sealed to confine vapors, mists, residues, dusts and deposits to the flammable vapor area. Panels for luminaires shall be separated from the luminaire to prevent the suface temperature of the panel from exceeding 200'F (93'C). As to 2013 CFC: 2404.6.2.2 Exterior luminaires. Luminaires attached to walls or ceilings of a flammable vapor area, but outside of any classified area and separated from the flammable vapor areas by vapor -tight glass panels, shall be suitable for use in ordinary hazard locations, Such luminaires shall be seviced from outside the flammable vapor areas. As to 2013 CFC: 2404.6.2.3 Integral luminaires. Luminaires that are an integral part of the walls or ceiling of flammable vapor area are allowed to be separated from the flammable vapor area by glass panels that are anintegral part of the luminaire. Such luminaires shall be listed for use in Class 1, Division 2 or Class II, Division 2 locations, whichever is applicable, and also shall be suitable for accumulations of deposits of combustible residues. Such luminaires are allowed to be serviced from inside the flammable vapor area. As to 2013 CMC: 505.1 General A mechanical ventilation or exhaust system shall be installed to control, capture, and remove emissions generated from product use or handling where required in accordance with the building code or fire code and where such emissions result in a hazard to life or prop.,rty. The design of the system shall be such that the emissions are confined to the area in which they are generated by air currents, hoods, or enclosures and shall be exhausted by a duct system to a safe location or treated by removing contaminants. Ducts conveying explosives or flammable vapor, fumes, or dust shall extend driectly to the exterior of the building without entering other spaces and shall not extend into or through ducts and plenums. Exception: Ducts conveying vapor or fumes having flammable consitituents less than 25 percent of their lower flammability Limit (LFL) shall be permitted to pass through other spaces. As to 2013 CFC: 2404.7.6 Termination point. The termination point for exhaust ducts discharging to the atmosphere shall not be less than the following distances: 1. Ducts conveying explosive or flammable vapors fumes or dusts: 30 feet from the lot line; 10 feet from openings into the buildiatng; 6 feet from exterior walls and roofs; 30 feet from combustible walls or openings into the building thare in the direction of the exhaust discharge; 10 feet above adjoining grade. 2. Other product -convey outlets: 10 feet from the lot line; 3 feet from exterior walls and roof; 10 feet from openings into the building; 10 feet above adjoining grade. As to 2013 CFC: 2403.2.6 Smoking prohibited. Smoking shall be prohibited in flammable vapor areaa and hazarhous materials storage rooms associated with flammable finish processes. is No Smoking" signs complying with Section 310 shall be conspicuously posted in such areas. As to 2013 CFC 2403.2.7 Welding warning signs. hall not be conducted in or adjacent to flammable vapor areas Welding, cutting and similar spark -producing operations s or dipping or coating operations unless precautions have been taken to provide safety. Conspicuous signs with the following warning shall be posted in the vicinity of flammable vapor areas, dipping operations and paint storage rooms: NO WELDING THE USE OF WELDING OR CUTTING EQUIPMENT IN OR NEAR THIS AREA IS DANGEROUS BECAUSE OF FIRE AND EXPLOSION HAZARDS. WELDING AND CUTTING SHALL BE DONE ONLY UNDER THE SUPERVISION OF THE PERSON IN CHARGE. As to 2013 CFC: 2404.7.3 Air Velocity. Ventilation systems shall be designed, installed and maintained such that the average air velocity over the open face ad the booth, or booth cross section in the direction of airflow during spraying operations, shall not be less than 100 feet per minute (0.51m/s). 11 1`1 150 feet of all portions of the building. Call 530-538-7888 to schedule a site visit prior to final to verify Address: fire access layout and markings. Ensure structure has appropriate building identification. Minimum 4" �� high and 0.5 stroke. Ensure the ihers: street address is posted at the street main entrance and on the main or first building encountered. Fire Extingus Extinguishers must be mounted on_a bracket or in a cabinet with the top not more than five feet above the floor. Base requirements are one 2A:10B:C (minimum rating) fire extinguisher is required with no more than 75 feet travel distance. Some areas may require high rated extinguishers with less maximum travel distance, depending on use. Extinguishers may be required to have a sign mounted above in order to be visible from a distance. Exhaust discharge point C _ O" Up -flow canopy damper weather cap ---i 25.5" DIAMETER EXHAUST STACK r ,`•,+si i t 1 / .,. V FOR' or ,y (/v r'ATir DY Pre -filter intake air tower - 34" Diameter Stackring Rainguard I Rainguard �r---- -�I' - 34" Diameter Stack Section 28'-4„ g.. a- i 12'-0" DRAWING SCHEDULE PAGE # As to 2013 CFC: 2404.6.1.2.1 Interlocks The spraying appartus, drying apparatus and ventilating system for the spray booth or spray room shall be equipped with CODE REQUIREMENTS/DWG SCHEDULE interlocks arranged to: Sheet -2 1. Prevent opertion of spraying apparatus while drying operations are in progress. for a of not less than 3 minutes before the 2. Purge spray vapors from the spray booth or spray room period AFC EQUIPMENT ELEVATION VIEWS drying apparatus is rendered operable. 3. Have the ventilating system maintain a safe atmosphere within the spray booth or spray room during the drying Sheet -4 process and automatically shut off drying apparatus in the event of a failure of the ventilating system. booth 200'F (93'C). 4. Shut off the drying apparatus automatically if the air temperature within the exceeds D As to 2013 CFC: 2404.4 Fire protection Sheet -6 Spray booths and spray rooms shall be protected by an approved automatic fire extinguishing system complying with Chapter 9. I Protectection shall also extend to exhaust plenums, exhaust ducts and both sides of dry filters when such filters are used. AMS1000C ASEMBLY DRAWING O AFC EQUIPMENT ELECTRICAL DRAWING !�7 As to 2013 CFC: 2404.4.1 Fire extinguishers. -0 Portable fire extinguishers complying with Section 906 shall be provided for spraying areas in accordance with the requirements DC7 for an extra (high) hazard occupancy. C/ C/) CFC: 2404.7.7 Fan motors and belts. 0Electric �7 As to 2013 motors driving exhaust fans shall not be placed inside booths or ducts. Fan rotating elements shall be nonferrous or nonsparking duct booth unless the belt and pulley within Cf')or the casing shall consist of, or be lined with, such material. Belts shall not enter the or theduct are tightly enclosed. As to 2013 CFC: 2404.3 Design and construction. Design and construction of spray rooms, spray booths and spray spaces shall be in accordance with Sections 1504.3 through 1504.3.3.1. As to 2013 CFC: 2404.3.1.1 Floor. Combustible floor construction in spray rooms shall be covered by approved, noncombustile, nonsparking material, except where combustible coverings, including but not limited to thin paper or plastic and strippable coatings, are utilzed over noncombustible materials to facilitate cleaning operations in spray rooms. GENERAL NOTES I 1. AFC SPRAY BOOTHS ARE CONSTRUCTED OF MATERIALS CONFORMING TO NFPA 33, CHAPTER 3, SECTION 3-1 AND SECTION 3-1.1. 2. AFC SPRAY BOOTHS SHALL BE SEALED WITH MATERIALS AS PER NFPA 33, CHAPTER 3, SECTION 3-1.2. 3. WHEN INSTALLED, AFC SPRAY BOOTHS SHALL BE SEPARATED FROM SURROUNDING AREA AS PER NFPA 33, CHAPTER 3, SECTION 3-1.3 AND SECTION 3-3. ! 4. ALL OBSERVATION GLASSES & GLASSES FOR LIGHT FIXTURES ARE TEMPERED Exhaust discharge point SAFETY GLASS THAT CONFORM TO NFPA 33, CHAPTER 3, SECTION 3-5. 5. VENTILATION OF ALL AFC SPRAY BOOTHS SHALL CONFORMS TO NFPA 33, _ SECTION 3-6, SECTION 3-6.1 THROUGH SECTION 3-6.5. Up -flow canopy damper weather cap THE INSTALLED SPRAY BOOTH SHALL MEET THE REQUIREMENT OF THE 2013 it Pre -filter intake air tower CALIFORNIA BUILDING CODE, CALIFORNIA MECHANICAL CODE. CALIFORNIA PLUMBING CODE AND CALIFORNIA FIRE CODE, THE 2013 CALIFORNIA ENERGY CODE AND THE ! 25.5" DIAMETER EXHAUST STACK 2013 CALIFORNIA ELECTRICAL CODE. l 34" Diameter Stackring� Rainguard Rainguard 4 34" Diameter Stack Section Roof Flashing Roof Flashing ------------------, I , I E j I 1 I �-1 Ill I I I 1f 45' 34 diameter Elbow y , � I I _----. T .... ....._.... __ _ __ _ __� ._._ '--__-__ I ._ _._. ___........_................ ... ......... ...._.... _.... _..___.___......_...._.. .... .___....__ 45' 34 diameter Elbow 31 --- - _- -- } -- yY _ I I __ _ / , 1 I I II I 1 ��� i•; , I;I i ' I 28'-0" _ 281-4$' loc ted ting re gg� = SZOE 1,-Zoily,�- i I DECLARATION OF COMPLIANCE: THE PAINT SPRAY BOOTH MANUFACTURED BY AFC, INC., ARE DESIGNED FOR CODE APPROVAL. EACH BOOTH IS FABRICATED FROM 18 GAGE GALVANIZED STEEL, THROUGHOUT, TO EXTEND NORMAL LIFE EXPECTANCY BY FIVE TIMES. THE GALVANIZED CLASSIFICATION OF G-90 ZINC RATING IS 1.25 OUNCES PER SQUARE FOOT. ASTM A527LFQ. ALL MODELS ARE MANUFACTURED TO THE STANDARDS OF THE NATIONAL BOARD OF FIRE UNDERWITERS FOR SPRAY BOOTHS, AS RECOMMENDED BY THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA 33, 2011 EDITION), OCCUPATION SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS, INTERNATIONAL FIRE CODE (IFC 2012), CHAPTER 24 FLAMMABLE FINISHES, AND ENVIRONMENTAL PROECTION AGENCY (EPA) REQUIREMENTS. STANDARD COMPONENTS AND ACCESSORIES ARE AVAILABLE TO COMPLY WITH ANY SPECIAL STATE OR LOCAL CODE REQUIREMENTS. EXHAUST AND MAKE-UP AIR FAN: THIS FAN IS EQUIPPED WITH A NON -SPARKING BLADE THAT IS DRIVEN BY BELTS ENCLOSED IN A STEEL CYLINDER. THIS LOCATION OF THE BELTS PROVIDES MAXIMUM PROTECTION FROM THE AIR STREAM.THE ELECTRIC MOTOR IS LOCATED OUTSIDE OF THE FANS 16 GAUGE STEEL LINER SO THAT MOTOR IS NOT EXPOSED TO FLAMMMABLE VAPOR. ON CROSSFLO BOOTH THE AIR VELOCITY HAS A MINIMUM OF 100 LFPA (LINEAR FEET PER MINUTE.) AND ON SIDE DOWN DRAFTS, DOWNFLO MODELS THE AIR FLOW IS A MINIMUM OF 25% OF THE LOWER FLAMMABLE LIMIT. ELECTRIC MOTOR: THE MOTOR CONFORMS TO NATIONAL ELECTRIC MANUFACTURERS ASSOCIATION (NEVA) RATINGS, CLASS A OR B INSULATED. MOST GOVERNMENT AND INDUSTRY MOTOR STANDARDS ARE BASED ON NEMA). ALSO , REFERNCE UNDERWRITERS LABORATORIES (UL) LISTING E, 57948 DAYTON ELECTRIC MOTORS. LIGHTS: THE LIGHTS ARE UL APPROVED (21209) AND ARE MOUNTED AND SERVICED FROM OUTSIDE OF THE BOOTH. WINDOWS ARE .250" TEMPERED GLASS, SEALED FROM THE INSIDE TO INSURE A VAPOR PROOF SEAL. THE SAME APPROVED LIGHTING FIXTURE IS AVAILABLE IN AN ARRANGEMENT THAT MAY BE SERVICED FROM THE INTERIOR OF THE BOOTH AND MAINTAIN THE VAPOR PROOF CHARACTERISTIC. VALVES: IMAGNETIC AIR VALVES ARE NEMA TYPE 1 WITH ENCLOSED SOLENOID. INTERLOCK CONFORMS TO IFC SECTION 1504.6.1.2.1 INTERLOCKS: PREVENTS OPERATION IF MAN ACCESS DOOR OR DRIVE-IN DOORS ARE OPENED LIMIT SWITCH WILL STOP THE EXHAUST FAN MOTOR AND THE PAINTERS AIR VALVE FROM OPERATING AND S 20 0° F 93°C . IF EXCEEDS ONS ) OPERATIONS PREVENTS ALL OPE THIS BOOTH IS LISTED UNDER ETL # 53993. s to 2013 CFC: 2404.3.2.1 Construction. ,ray booths shall be constructed of approved noncombustible materials. Aluminum shall not be used. Where wall or ceiling ,semblies are constructed of sheet metal, single -skin assemblies shall be no thinner than 0.0478 inch (18 gage) (1.2mm) id each sheet of double -skin assemblies shall be no thinner than 0.0359 inch (20 gage) (0.9mm). Structural sections of ,ray booths allowed to be sealed with latex -based or similar caulks and sealants. ,s to 2013 CFC: 2404.3.2.4 Means of egress eons of egress shall be provided in accordance with Chapter 10. Kception: Means of egress doors from premanfactured spray booths shall not be less than 30 inches (762mm) in width by 0 inches (2032mm) in height. Access: An a roved fire apparatus access road not less than 20 feet wide shall be provided for access within 5.5.1 Panels for lights fixtures or for observation shall be of heat-treated glass, laminated glass, wired glass, or hammered wired glass and shall be sealed to cofine vapors, mists, residues, dusts, and deposits to the spray area. Exception: Listed spray booth assemblies that have vision panels constructed of other materials shall be permitted. 5.5.2 Panels for light fixtures shall be separated from the fixture to prevent the surface temperature of the panel from exceeding 93°C (200°F). 5.5.3 The panel frame and method of attachment shall be designed to not fail under fire exposure before the vision panel fails. 5.5.4 Observation panels for spray booths that are used exclusively for powder coating processes shall be permitted to be constructed of fire-resistant combusible materials. 5.6 Ventilation. Spray areas that are equipped with ventilation distribution or baffle plates or with dry overspray collection filters shall meet the requirements of 5.6.1. through 5.6.5. 5.6.1 Distribution plates or baffles shall be constructed of noncombusible materials and shall be readily removable or accessible for cleaning on both sides. 5.6.2 Filters shall not be used when applying materials known to be highly susceptible to spontaneous heating or spontaneous ignition. 5.6.3 Supports and holder for filters shall be constructed of noncombusible materials. 5.6.4 Overspray collection filters shall be readily removable or accessible for cleaning or replacement. 5.6.5 Filters shall not be alternated used for different types of coating materials if the combination of materials might result in spontaneous heating or ignition. (See also Section 10.9.) 2011 Edition NFPA 33 Standard for Spray Application Using Flammable or Combustible Materials Chapter 6 Electrical and Other Sources of Ignition: 6.3.1.2 Class 1, Division 2 Locations. As defined in 500.5(B) (2) of NFPA 70, National Electrical Code, a Class 1, Division 2 location shall be any location where one the following conditions exists: (1) A flammable gas or volatile flammable liquid is handled, processed, or used but any flammable gas, vapor or liquid is confined within a closed container or a closed system from which it can escape only in case of accidental rupture or breakdown of the container or system or in case of abnormal operation of the equipment. (2) An ignitible concentration of flammable gas or vapor is normally prevented by positive mech- anical ventilation but might exit because of failure or abnormal operation of the ventilating equip- ment. (3) An ignitible concentration of flammable gas or vapor might occasionally be transmitted from an adjacent Class 1, Divison 1 location, unless such transmission is prevented by positive pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided. As to 2013 CFC: 2404.6.2.1 Glass panels Panels for luminaires or for observation shall be heat-treated glass, wired glass or observation shall be heat-treated glass, wired glass or hammered wire glass and shall be sealed to confine vapors, mists, residues, dusts and deposits to the flammable vapor area. Panels for luminaires shall be separated from the luminaire to prevent the suface temperature of the panel from exceeding 200'F (93'C). As to 2013 CFC: 2404.6.2.2 Exterior luminaires. Luminaires attached to walls or ceilings of a flammable vapor area, but outside of any classified area and separated from the flammable vapor areas by vapor -tight glass panels, shall be suitable for use in ordinary hazard locations, Such luminaires shall be seviced from outside the flammable vapor areas. As to 2013 CFC: 2404.6.2.3 Integral luminaires. Luminaires that are an integral part of the walls or ceiling of flammable vapor area are allowed to be separated from the flammable vapor area by glass panels that are anintegral part of the luminaire. Such luminaires shall be listed for use in Class 1, Division 2 or Class II, Division 2 locations, whichever is applicable, and also shall be suitable for accumulations of deposits of combustible residues. Such luminaires are allowed to be serviced from inside the flammable vapor area. As to 2013 CMC: 505.1 General A mechanical ventilation or exhaust system shall be installed to control, capture, and remove emissions generated from product use or handling where required in accordance with the building code or fire code and where such emissions result in a hazard to life or prop.,rty. The design of the system shall be such that the emissions are confined to the area in which they are generated by air currents, hoods, or enclosures and shall be exhausted by a duct system to a safe location or treated by removing contaminants. Ducts conveying explosives or flammable vapor, fumes, or dust shall extend driectly to the exterior of the building without entering other spaces and shall not extend into or through ducts and plenums. Exception: Ducts conveying vapor or fumes having flammable consitituents less than 25 percent of their lower flammability Limit (LFL) shall be permitted to pass through other spaces. As to 2013 CFC: 2404.7.6 Termination point. The termination point for exhaust ducts discharging to the atmosphere shall not be less than the following distances: 1. Ducts conveying explosive or flammable vapors fumes or dusts: 30 feet from the lot line; 10 feet from openings into the buildiatng; 6 feet from exterior walls and roofs; 30 feet from combustible walls or openings into the building thare in the direction of the exhaust discharge; 10 feet above adjoining grade. 2. Other product -convey outlets: 10 feet from the lot line; 3 feet from exterior walls and roof; 10 feet from openings into the building; 10 feet above adjoining grade. As to 2013 CFC: 2403.2.6 Smoking prohibited. Smoking shall be prohibited in flammable vapor areaa and hazarhous materials storage rooms associated with flammable finish processes. is No Smoking" signs complying with Section 310 shall be conspicuously posted in such areas. As to 2013 CFC 2403.2.7 Welding warning signs. hall not be conducted in or adjacent to flammable vapor areas Welding, cutting and similar spark -producing operations s or dipping or coating operations unless precautions have been taken to provide safety. Conspicuous signs with the following warning shall be posted in the vicinity of flammable vapor areas, dipping operations and paint storage rooms: NO WELDING THE USE OF WELDING OR CUTTING EQUIPMENT IN OR NEAR THIS AREA IS DANGEROUS BECAUSE OF FIRE AND EXPLOSION HAZARDS. WELDING AND CUTTING SHALL BE DONE ONLY UNDER THE SUPERVISION OF THE PERSON IN CHARGE. As to 2013 CFC: 2404.7.3 Air Velocity. Ventilation systems shall be designed, installed and maintained such that the average air velocity over the open face ad the booth, or booth cross section in the direction of airflow during spraying operations, shall not be less than 100 feet per minute (0.51m/s). 11 1`1 150 feet of all portions of the building. Call 530-538-7888 to schedule a site visit prior to final to verify Address: fire access layout and markings. Ensure structure has appropriate building identification. Minimum 4" �� high and 0.5 stroke. Ensure the ihers: street address is posted at the street main entrance and on the main or first building encountered. Fire Extingus Extinguishers must be mounted on_a bracket or in a cabinet with the top not more than five feet above the floor. Base requirements are one 2A:10B:C (minimum rating) fire extinguisher is required with no more than 75 feet travel distance. Some areas may require high rated extinguishers with less maximum travel distance, depending on use. Extinguishers may be required to have a sign mounted above in order to be visible from a distance. Exhaust discharge point C _ O" Up -flow canopy damper weather cap ---i 25.5" DIAMETER EXHAUST STACK r ,`•,+si i t 1 / .,. V FOR' or ,y (/v r'ATir DY Pre -filter intake air tower - 34" Diameter Stackring Rainguard I Rainguard �r---- -�I' - 34" Diameter Stack Section 28'-4„ g.. a- i 12'-0" DRAWING SCHEDULE PAGE # DESCRIPTION :S:eet-1 CODE REQUIREMENTS/DWG SCHEDULE Sheet -2 BUILDING ELEVATION VIEWS Sheet -3 AFC EQUIPMENT ELEVATION VIEWS Sheet -4 GAS LINE AND AIR LINE ROUTE Sheet -5 AFC EQUIPMENT DETAILS Sheet -6 SDDP2814CDT ASSEMBLY DRAWING Sheet -7 AMS1000C ASEMBLY DRAWING Sheet -8 AFC EQUIPMENT ELECTRICAL DRAWING Sheet -9 CITY OF CHICO ZONING MAP 6/1Z2013 Sheet -10 CITY OF CHICO GENERAL PLAN 1/1/13 AFC FINISHING SYSTEMS 250 AIRPORT PARKWAY, OROVILLE, CA 95965 (800) 331-7744 (530) 533-0179 (FAX) http://www.afc-co.com email: sales@afc-ca.com THIS DRAWING IS THE PROPERTY OF AFC FINISHING SYSTEMS AND IS NOT TO BE LOANED, COPIED OR DUPLICATED UNLESS IN DIRECT CONNECTION WITH AFC FINISHING SYSTEMS. ALL RIGHTS RESERVED. THIS DRAWING MUST BE RETURNED UPON REQUEST BY AFC FINISHING SYSTEMS. DRAWN FOR: COLLISION PROS INC. 2910 Highway 32 Chico, CA DESCRIPTION: Code Requirements / Drawing Schedule DRAWN BY: JDD CHECKED BY: APPROVED BY: DATE: 12/03/14 WING NAME: "-1 ' DRA • 8 OR 1 4 SCALE . 4 BY: / INSTALLED BY: FIELD CHANGED Sheet -1 Address: 2910 Highway 32 Chico, CA Description—Use of Building: Auto Body Repair Facility Zoning: ML Light Manufacturing All Restrooms are ADA compliant 2—ADA Parking stalls Building Access Doors are ADA compliant Building Type: Meta Building Floor: Concrete Collision Pros Inc. COLLISION PROS INC. AL WIRING TO COMPLY WITH NFPA 70, THE INSIDE SE RVICE LIGHT DOORS ASSEMBLY EXHIAUST A R FAN TYPICAL DOOR LIMIT NOTE. ALL ELECTRIC / VERTICAL WALL PANEL � ION NATIONAL ELECTRIC CODE, LATEST EDITION, UNLESS STATED \ ACCESS DOOR FRAME INSTALLATION � BOOTH VERTICAL WALL PANEL TYPICAL ANCHOR SPACING IS 24 ON CENTERS SWITCH T OTHERWISE BY LOCAL AUTHORITY HAVING JURISDICTION. _ 3 4 14x4 TEK SCREWS , 25 1 /2" TUBE-AXIAL FAN TO MOVE 7,000 CFM @ 1/2" STATIC PRESSURE FLEX CONDUIT CUT 22"X 56 3/4" HOLE IN VERTICAL WALL PANEL NEC PLACE INSIDE SERVICE LIGHT FRAME IN HOLE 10GA STEEL MOTOR—MOUNT BRACKET-- APPROVED HAZARDOUS EATON CUTLER-HAMMER MODEL: 10316H1002 -USE 3/16" POP RIVETS TO ATTACH LIGHT FRAME TO VERTICAL WALL PANEL BASE ANGLE WEDGE ANCHOR DETAIL JJ POUR LOCATION T FIXTURE TO INSIDE SERVICE LIGHT FRAM 2 3/4"STEEL-ROUND ROD PIVOT SHA T SWITCH B ACKET I SE 3/16 POP RIVETS TO ATTACH LIGHT FITTING LIMIT SWITCH TYPE EX HAZARDOUS LOCATION LIMIT FOUR LIGHT FIXTURE TUBES I NON SPARKING BLADE 16GA: STEEL BELT TUB I � I � I BOOTH EXTERIOR BOOTH INTERIOR DOOR BRACKET DESIGNED FOR EXTREME ENVIRONMENTAL SERVICE ACCESS DOOR IN NEMA 7-9 LOCATIONS WHERE EXISTS A DANGER EXPLOSION OF FLAMMABLE 1 lo AN INTERNAL OR EXTERNAL I VERTICAL WALL PANEL a I TEK SCREW DOOR HINGE GASES VAPORS O METAL ALLOY OR GRAIN DUST. TYP. - 24" x 96" ADJUSTMENT SCREW I i I 18GA GALVANIZED STEEL / I I 28 1/2" 25 1/2" ASE ANGLE �I DOOR \ / TYP. 2" x 2" x 120" MAN \ 2P BRIXON LATCH I 14GA GALVANIZED STEEL OBERSERVATION / \ MINIMUM 3000 PSI CONCRETE TEK SCREW WINDOW \ \ / / 1 /4 - 14 x 3/4 ' NOTE: 1 " WIDE DOUBLE FACE TAPE AROUNLj D OUTSIDE EDGE CONCRETE FLOOR DRILL & TAP SCREW 2500 HEX WASHER FLEX CONDUIT — OF TEMPERED GLASS WINDOW ON BOTH SIDES. AT LEAST 2 PER � ADJUSTMENT BRACKET 1/4" TEMPERED SAFETY GLASS 19 1/2"X 53 1/2" ERTICAL PANEL 2HP ELECTRIC MOTOR TYPICAL DOWNFLO MAN—DOOR LIMIT SWITCH , OR DOWN i 10GA STEEL MOUNTING BRACK N OR OUT) (UP ) 230VOLTS 60HZ USE 3-TEK SCREWS OR POP RIVETS TO ATTACH CONTINUOUS HINGE TO FRAME TYPICAL: 3-PHASE NEC APPROVED POUR FITTING-- / °° 25 1/2 HAZARDOUS LOCATION USE 3/16" POP RIVETS TO ATTACH LIGHT FRAME TO VERTICAL WALL PANEL a WAIL PANEL INSIDE SERVICE LIGHT FRAME d ° d d °a 1" TGP SHAFT LIMIT SWITCH HEADER PANEL 3/16 STEEL RING o+—� 4 � d DOOR BRACKET ° _____--- ° rr�� BRIXON LATCH TO MAN ACCESS DOOR LIGHT FIXTURE ° a ° r I I I__ I Q d L----- --r_s i , - L------------� d rL l LEFT DRIVE DOOR INSIDE SERVICE LIGHT DOORF_ -- � o RIGHT DRIVE DOOR ° 4° 17 1/2" I rl-1� ° 16" O �r I 1 o d d ° � II < _ _ ----------------- < __________ ___ - _ _ _ _ _ I Q .-_______________ AFC 2P Brixon LctchI 6" -+- ---_ I a a TEK W ; ' j ` I RED HEAD TRUBOLT WEDGE ANCHOR 1 60A STEEL LINER MOTOR SHEAVE TWO GROOVE TYPICAL DRIVE—DOOR LIMIT SWITCH ( ANCHOR DIA: 3/8" d BROWNING BELT (1 I I MINIMUM EMBEDMENT DEPTH: 2" 3/16" STEEL RING Q P I ! STEEL STRENGTH (TENSION) 4,200 LBS FAN SHEAVE TWO GROOVE STEEL STRENGTH (SHEAR) 1,830 LBS (FOR SEISMIC LOADS=1,545 BROWNING PILLOW BLOCK BEARING �� » TENSION AND SHEAR VALUES (Ibs/kn) in concrete WEIGHT OF FAN: 86 LBS TEK SCREW SIZE 1 f 4 —14 X 3/4 �� TEK SCREW SIZE 1/4"-14 X 3/4" � � Q%���� I i I I ICC EVALUATION SERVICE, INC—# ESR-2427 WEIGHT OF 3HP MOTOR: 44 LBS WEIGHT OF FAN AND MOTOR 130 LBS AR LOAD PER SCREW THRU LAPPED SHEAR LOAD PER SCREW THRU LAPPED S �� I I I' SHE r 1 I II I d ° MAKE–UP AIR 34' TUBE–AXIAL FAN TO MOVE 14,000 CFM @ 1 /2" STATIC PRESSURE 18 GAGE PANEL 1442 LBS. I AGE PANEL 1 442 LBS. O I•I I I ° ° E 1 ; I I ;! j I MINIMUM 3000 PSI CONCRETE 10GA STEEL MOTOR—MOUNT BRACK \ I I 4" MINIMUM CONCRETE SLAB THICKNESS VARIABLE PITCH ' P NON SPARKING BLADE 3/4"STEEL—ROUND ROD PIVOT SHA �c I. 3 II 16G STEEL BELT TU DRILL TAP SCREW 3 3 2500 HEX WASHER 4 ��- I ICC EVALUATION SERVICE, INC# ESR-2427 4 4 – 3 4 P� i t 1/4 14 x / I Q Reissued August 2014 I 1 2015 DRILL 8c TAP SCREW This report Is subject to renewal November , 2500 HEX WASHER 1 4– 14 x 3/4 ��� �P� '} P �� III 13 37 34 0 15 � P G �; � ��� AFC 280 Magnetic air valve 15 PANEL A 1 �G _.._._...._.._.._.._.._.._. PANEL A 1— 16 18GA GALVANIZED PANEL B 16 1 BOA GALVANIZED PANEL B I , S`�-���ea E STEEL, CQ/LFQ A653 1 BOA GALVANIZED 2_..i �P�\O� STEEL, CQ/LFQ A653 18GA GALVANIZED SH A40 NCT, G-90 STEEL, CQ/LFQ A65 G SH A40 NCT, G-90 STEEL, CQ/LFQ A65 Jy„„r O I I f 16GA STEEL BELT TUBE RATING OF 1.25 OZ SH A40 NCT G-90 �.. '�`L -- RATING OF 1.25 OZ SH A40 NCT, G-90 �►e FOOT PER SQUARE FOOT RATING OF 1.25 OZ ' �\GAF. S� e� I t 3HP ELECTRIC 0 V PER SQUARE RATING OF 1.25 OZ Pkv ,� � �O � 10GA STEEL MOUNTING BRACK 208/230/460 VAC PER SQUARE FOOT �� TYPICAL: 3—PHASE 60HZ PER SQUARE FOOT"' SPS p� _ i 3a„ Py O 1 " TGP SHAFT �e G _ 3/16” STEEL RING I 1---------------T1--�' ----------------- _ it e �� - PSG•• : III _� L_-�yj G/'� L_______________J, G� I , —TYPICAL PANEL WIDT TYPICAL PANEL WIDT-1 L --------------- 19 1/2 18„ TYP �e _- SMC VX SERIES MODEL: VX2140Ell 1­0 111] -04N-30R1 ��pGro TYPICAL COMPANION CONNECTION DETAIL TYPICAL INTERLOCKING CONNECTION DETAIL ,�Q. x'13 �••� � �VP t MOTOR SHEAVE TWO GROOVE _.. �j•—.•_.. __. _ 16GA STEEL LINER BROWNING BELT VERTICAL WALL OUTSIDE VERTICAL WALL INSIDE 3/16” STEEL RING FAN SHEAVE TWO GROOVE AFC205 LIGHT FIXTURE ASSEMBLY BROWNING PILLOW BLOCK BEARING 4 — 14 x 4 TEK SCREW SIZE 1 /4"-14 X 3/4" MODEL: AFC 280 3„ LL TEK TEK SCREW 1,/4"X3/4"x14 DIA. PIPE SELF DRI MAGNETIC AIR VALVE » R U LAPPED QUICK CONNECT 3 Hp Motor enclosure Op€n Dripproof WEIGHT OF FAN: 1D5 LBS SCREWS, 1 FROM SHEAR EAR LOAD PER SCREW TH 18GA STEEL LIGHT CLIPS LBS Brand: Dayton Mfr. Model: 2NKY8B Motor type: 3—Phase WEIGHT OF MOTOR: 50 Nameplate RPM: 1770 Voltage: 208/230/460 TOTAL WEIGHT OF 155 LBS S 24 ON A I I END 18 GAGE PANEL 1442 LBS. SUPPLY AIR III; I I€' LIGHT FIXTURE � r! `'iii' NEMA/IEC Frame: 182T/184T Bearings: Ball CENTER AFC205 FOUR TUBE � ROOF PANEL Hz: 60/0 Nominal Efficiency: 89.5 R' �� 8GA STEEL LIGHT CLIP I EfficiencyGroup:NEMA Premium (R) TYP . — 2 4 x 120 __ I O _ Duty: Continuous c'" Standards: UL Recognized (E47479), CSA Certified (227508) 18GA GALVANIZED STEEL ...� ,PAINTERS AIR HOSE Rotation: CW CCW Shaft Diameter: 1-1/8" Shaft Length: 2-3/4" Overall Length: 14-1/8" 3 Hp Motor w eight: 50 Ibs _ t —4— ELECTRICAL WIRES DWYER MARK II MANOMETER DETAIL AFC 250 Manometer TIE—IN ANGLE 1 /4 . TEMPERD :SAFETY GLASS 19.5"X53.5" 1. MOUNT MANOMETER ON WALL OF BOOTH — 2x2 x 120 -� ���--- • BUTTS TYP. -- _. 2. USE LEVELING GAUGE AND LEVEL UNIT COUNTY 14GA GALVANIZED STEEL �T�. ���`���-----. 3. INSTALL "HIGH" SENSOR TO MEASURE DEC 17 2014 1/4 — 14 x 3/4` - „ PRESSURE INSIDE BOOTH _., DET SELF—DRILLING TEK SCREWS_ ;w 4. INSTALL LOW„ SENSOR TO MEASURE CM SERVICES WALL PANEL MIN. 2 PER ROOF PANEL PRESSURE INSIDE EXHAUST CHAMBER 1 WIDE 1/8 • THICK DOUBLE FACE TAPE 5. FILL MANOMETER WITH INCLUDED RED O TYP. — 20 x 120 T FORM A AIR TIGHT VAPOR BARRIER� 18GA GALVANIZED STEEL BETWEEN FRAME AND GLASS WINDOW MANOMETER FLUID 6. ADJUST TO READ ZERO (0) INCHES W.C. WITH �� BOOTH OFF WALL TO ROOF CONNECTION DETAIL PLENUM PANEL 7. APPLIED GREEN ARROW TO THE .50 „ W.C. MARK. TYP. - 20” x 120" �' : �`" OW TO THE 1 "W.C. MARK. I S T 18 A GALVANIZED STEEL 8. APPLIED RED ARROW 18GA STEEL LIGHT FRAME 2 1 TYPICAL 18GA STEEL PANEL HIGH SENSOR OW SENSOR (INSIDE EXHAUST CHAMBER)Inter e HIP PANEL CONNECTION ANGLE (INSIDE BOOTH)L— �, 1 /4 - 14 x 3/4 TYP. - 2"x2"x34", 45° NOTCH ONE SIDE -- DRILL & TAP SCREWS 14GA GALVANIZED STEEL '= -� .. `-_ FLUID FILL RG" oW 53993 2500 HEX WASHER HOLE O Dyer p 3 SPRAY APPLICATIONS I 2.4" ON CENTERAFC205 LIGHT FIXTURE DETAIL FlLL MARK II EDGE ON vlEw USING FLAMMABLE 2 INSIDE BOOTH BOOTH LIGHT PANEL AND COMBUSTIBLE v..c._===-=INCHES OF WATER COLUMN 1 ERIALS 0 .20.30.50 MAT r - INTAKE FILTER CELL BANK I _,05 .10 CONFORMS TO NFPA STD.33 ° TYP. - 40' x 120" � ZEROsu ° o 18GA GALVANIZED STEEL , HIP PANEL o O 0 0 TYP._ OUTSIDE BOOTH AFC205 LIGHT FIXTURE 0 18GA GALVANIZEDXSTEEL LIGHT CLIP TEK SCREW ZERO ADJUSTMENT LEVEL GAUGE 1/4" TEMPERED SAFETY GLASS UNIT MUST BE LEVEL DESCRIPTION DATE BY HIP TO PLENUM CONNECTION DETAIL PIPE GROUNDING CLAMP #10 SOLID COPPER WIRE GROUNDING BAR LOCATED IN CONTROL PANEL AMM JEW I ®®�® ER FLAME AMW ®� ® NEC 2011: 250.104 BONDING OF PIPING SYSTEMS AND EXPOSED STRUCTURAL STEEL. (B) OTHER METAL PIPING. IF INSTALLED IN, BURNER MODEL: ® ® ®®®® POW _. fi°1iSHltVf� SYSTEMS ATTTACH TO, A BUILDING OR STRUCTURE, A METAL PIPING SYSTEM (S), INCLUDING GAS PIPING, THAT IS LIKELY TO BECOME ENERGIZED CFC 2013 SECTION 2403.2.5 GROUNDING. METAL PARTS OF SPRAY BOOTHS, J 3OA-10 P B SHALL BE BONDED TO THE SERVICE EQUIPMENT ENCLOSURE; THE EXHAUST DUCTS AND PIPING SYSTEMS CONVEYING CLASS I OR Ii LIQUIDS #10 SOLID COPPER GROUNDED CONDUCTOR AT THE SERVICE; THE GROUND ELECTRODE SHALL BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH CALIFORNIA CONDUCTOR, IF OF SUFFICIENT SIZE; OR TO ONE OR MORE GROUNDIN CODE. METALLIC PARTS LOCATED IN RESIN APPLICATION AREAS, AFC FINISHING SYSTEM WIRE � ELECTRICAL ELECTRODES USED. THE BONDING CONDUCTOR (S) OR JUMPERS (S). INCLUDING BUT NOT LIMITED TO EXHAUST DUCTS VENTILATION FANS, SPRAY THE EQUIPMENT GROUNDING CONDUCTOR FOR THE CIRCUIT THAT IS �` APPLICATION EQUIPMENT, WORKPIECES AND PIPING, SHALL BE ELECTRICALLY - 250 AIRPORT PARKWAY, OROVILLE, CA 95965 LIKELY TO ENERGIZE THE PIPING SHALL BE PERMITTED TO SERVE AS GROUNDED. THE BONDING MEANS. THE POINTS OF ATTACHMENT OF BONDING (800) 331- co.c (530) email: sales@afc–ca.com (FAX) http://www.afc–ca.com email: salesC�afc–ca.com JUMPER (S) SHALL BE ACCESSIBLE. RESERVERIGHTS OR D. CONNECTIONUNLESS IN DIRECT D. THIS DRAWING MUST BE RETURN UPON EQUESTWITH AFC HBY AFC FINISHINGING TSYSTEMS. THIS DRAWING IS THE PROPERTY OF AFC FINISHING SYSTEMS AND IS NOT TO BE L S.ALL I I ' DRAWN FOR: PROS INC — — t _OCOLLISION . PIPE GROUNDING CLAMP : L iJl : [ _ oHighway32 Chico CA I � SCH 40 GAS PIPE F 291 � DESCRIPTION. A Equipment Details CFC 2013 SECTION 2403.2.5 GROUNDING. METAL PARTS OF SPRAY BOOTH �. C AND PIPING SYSTEMS CONVEYING CLASS I OR II LIQUIDS I EXHAUST DUCTS i SHALL BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH CALIFORNIA �/� ' ELECTRICAL CODE. METALLIC PARTS LOCATED IN RESIN APPLICATION AREAS, ' SIDE VIEW DRAWN BY. JD HEC D BY:PPROVED BY. ATE. 12/02/14 i INCLUDING BUT NOT LIMITED TO EXHAUST DUCTS VENTILATION FANS, SPRAY - -- --- -- – D C KEA 1 APPLICATION EQUIPMENT, WORKPIECES AND PIPING, SHALL BE ELECTRICALL GROUNDED. O C ❑ O INSTALLED BY: FIELD CHANGED BY: SCALE: 48 OR 1/4"=1' DRAWING NSheet-5 FRONT VIEW I" DIAMETER GAS PIP TOP VIEW 29A 32A 31A BOOTH SPECIFICATIONS * UNIT MODEL: SDDP3014CDT ETL-LISTED * LENGTH= 28'-4" O.D. / 28'-0" I.D. * WIDTH= 16'-4" O.D. / 14'-0" I.D. * HEIGHT= 11'-10" O.D. / 10'-0" I.D. * DOOR HEIGHT= 8'-0" (WITH LARGE OBSERVATION WINDOWS)) * DOOR WIDTH= 10'- 0" (WITH LARGE OBSERVATION WINDOWS) * (26) 20"X20"X2" FIBERGLASS ARRESTOR PADS CONSTRUCTION * 18 GA. G-90 GALVANIZED STEEL PANELS WITH "LOCKING" SEAL FLANGES. * PANEL ASSEMBLY TYPE= 1/4" X 3/4" SELF -TAPPING SCREWS ON 12" CENTERS TYP. * DOOR FRAME CONSTRUCTUON: 2" X 1-1/2" X 1/4" HRS ANGLE. * DOOR HINGES: 4" X 4" X HEAVY DUTY STEEL ( 3 -EA. PER DOOR ) EXHAUST Alli FAP! * TWO EXHAUST FANS: 25 1/2" DIAMETER NON-SPRAKING BLADE * TWO MOTORS: 2 HP. 230 VAC 3-PHASE 60Hz. * VOLTAGE= 230 VAC @ 125% AMPACITY=8.5 EACH * C.F.M. RATING=14,000 © 1/2" STATIC PRESSURE LIGHTING SPECIFICATIONS * LIGHT FIXTURE TYPE= L.D.P.I. 4 -TUBE FLORESCENT U. L. LISTED * VOLTAGE= STANDARD: 120 / 60 HRTZ. AMPACITY: 1.0 PER FIXTURE. * QUANITY= 14 -EA. TOTAL. * TYPE = (12) STANDARD OPEN TYPE. * TYPE = (2) CLASS 1 DIVISION 2 INSIDE SERVICE TYPE. 3' —10 " cm �ISiE� ntertek MODEL: SDDP2814CDT REPORT NO. 3069024-001 INSPECTION, TESTS AND EVALUATION OF PAINTING SPRAY BOOTHS RENDERED TO AFC FINISHING SYSTEMS OROVILLE, CA ISSUED: FEBRUARY 25, 2005 CONFORMS TO NFPA STD 33 3,-10 )) 3'-10" 1 -0 3'-10" 9-10" 3'-1 0" _ 10 —0 JlfriY''``��D4\EjrtpVELC I �V Li}{�?ul � CM �rSTEO ntertek 53993 SPRAY APPLICATIONS USING FLAMMABLE AND COMBUSTIBLE MATERIALS CONFORMS TO NFPA STD.33 \ ` -- ~____ /---' \ ` ' '^ __' � __�__�__� ��___�'- _- _ ' � - /r- -~ / L / ����� ��� �`�J� l 4� � � -�� � �.= � ,5, �; /� �c ,�� G � a fi �'� ___ __ _- _ _ __ � .. a Y r