Loading...
HomeMy WebLinkAboutB15-2875 040-570-019r � , SEQUOIA E N G I N E E R I N G CIVIL & STRUCTURAL Structural Calculations Client: Keith and Joy Book Job#: 15-045 Project: Book Barn Address: 153 Heavy Horse Lane, Durham, CA APN: 040-570-019 Calculation Index Page # • Project Layout 1 • Gravity Analysis 2 • Lateral Analysis 2-13 • Door End Frame Analysis 14 • Steel Element Analysis 15-22 • Weld Analysis 23-24 • Wood Beam and Joist Analysis 25-29 • Concrete Pilaster Analysis 30 • Footing Analysis 31 -32 11 F. BUTTE COUNTY JAN 15 2016 �Jan 14, 2016 DEVELOPMENT SERVICES PERMIT # 8 1 BUTTE COUNTY T SERVICES `EVIDLNGOREVIEWED MPIACE VSDATE Y_p � This calculation package is only valid for the project location as listed Above and may not be used for another site without the authorization of Sequoia Engineering. Sequoia Engineering claims no responsibility for any structural design not specifically addressed in this calculation package. Calculations and plans are not valid until reviewed and approved by the governing building department. 467 East 2nd Ave, Chico, CA 95926 (530) 591-7258 Chad@sequoiacivil.com a.ti 4 40'-0 s -0 : zae cP sno W" spromm- DY 6X71 PIOP DEAN LiLL1LULulLulu 9TORA6E ro am Pr EQUIPI•� 9TORAM PEW d1 aaw Pr STORAGE callcatale ow emR Pr gow �m ! MW PID 11WAL PIR PAD MTAL SIAM DO. sTAM DO. r PIR PAD WrALIT 1 bTAM DO. 1 4 UTILITY .o am R c tlD •A!d ELf M DAM DOOR DO. FLOOR PIAN !1 NIL -f--Ic - CIVIL & STRUCTURAL BOOK BARN PROJECT LAYOUT 4 1 Gravity Load Development Project: Book. Barn Date: 11/13/2015 = Comments: Units: lbs & feet (UNO) Gravity Loads: M Slope= 6 to 12 Roof Dead Load Ply 2.5 psf Roofing 2.0 psf Framing 2.5 psf Gyp 0.0 psf Insul 0.0 psf Sprinklers 0.0 psf Misc 2.3 psf Total (sloped) 9.3 psf Total (horiz) 10.0 psf Roof Live Load Construction 20.0 psf Wall Dead Load Siding 5.0 psf (exterior) 3/8 Ply. 1.8 psf 2x Framing 1.7 psf Gyp. 2.2 psf Insul. 1.0 psf Misc. 2.3 psf Total 14.0 psf Wall Dead Load 2x Framing @ 16" o.c. 2.2 psf (interior) Gyp. 2 sides 4.4 psf Misc 2.4 psf Total 9.0 psf Floor Dead Load Framing @ 16" o.c. 1.5 psf 3/4" ply 2.25 psf Gyp. 0 psf Flooring 2.5 psf Misc. 5.7 psf Total 12.0 psf Floor Live Load AG Storage 60.0 psf Pg. 2 Pg. 3 Design Maps Summary Report User -Specified Input Report Title Book Barn Mon November 16, 2015 20:05:01 UTC Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available in 2008) Site Coordinates 39.626440N, 121.71037°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III USGS-Provided Output Ss = 0.609 g S,.,s = 0.799 g SDs = 0.533 g Sl = 0.267 g Sr„ = 0.498 g So, = 0.332 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRV building code reference document. MCER Response Spectrum 0.99 0.80 0.72 0.64 0.56 0.48 y 0.40 0.32 0.2a 0.16 0.08 0.00 0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 Period, T (sec) Design Response Spectrum 0.54 0.48 0.4a 0.36 0m 0.30- 0.24- 0.19-- 0.12-- 0.06-- 0.00 .3D0.240.190.1z0.060.00 0.00 0.30 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.80 2.00 Period, T (sec) For PGA,„ TI, CRs, and CRI values, please view the detailed report. Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. Pg. 4 Equivalent Lateral Force Procedure ASCE 7-10 Seismic Loads Project: Book Barn Date: 11/16/2015 Comments: Units: kips c& feet (LINO) Description Symbol Value Units Source Zip Code ftA2 psf kis Wall Line Longitude ULT (kis 39.62644 Deg Google Earth Latitude 0 121.71037 Deg Google Earth Occupancy 2 2 0 Table I -I Site Class 0.71 D A Chapter 20 Seismic Deisgn Category 0 D 0.71 Table 11.6-1 Mapped 0.2 sec spectral response Ss 0.609 °log USGS website Mapped I sec spectral response S, 0.267 %g USGS website Response Modification R 6.5 - Light Framed Shear Walls - Table 12.2-1 Importance Factor I 1 Table 11.5-1 (Upper level governs for R value Lower level Strutural Height h„ 11 ft R = 7.0 or steel plate shear walls. Use R = 6.5) Peroid Parameter Ct 0.02 English Table 12.8-2 Peroid Parameter x 0.75 English Table 12.8-2 Long Period TL 16 sec Figure 22-16 Aprx. Fundamental Period Ta 0.1208 sec Section 12.8.2.1 Site Coefficient Fa 1.3130 Table 11.4-1 Site Coefficient Fv 1.8660 Table 11.4-2 MCE Spectral Response Sms 0.7996 Eq. 11.4-1 MCE Spectral Response Sm I 0.4982 Eq. 11.4-2 Design Spectral Response (0.2 Sec) SDS 0.533 %g Eq. 11.4-3 Design Spectral Response (1.0 Sec) So, 0.332 %g Eq. 11.4-4 Coefficient for Upper Limit Cu 1.400 Table 12.8-1 Deflection Amplification Factor Cd 4 Table 12.2-1 Overstrength Factor Wo 3 Table 12.2-1 Max Seismic Response Coeff Cs max 0.423 Eq. 12.8-3 MinSeismic Response Coeff Cs min 0.023 Eq. 12.8-5 Seismic Response Coefficient Cs 0.082 Section 12.8.1.1 Vertical Dist Exp k 1 I ISection 12.8.3 Vertical Distribution of Seismic Forces LEVEL STORY HT hi wi wishiAk Cvx VEQ E VEQ Diaphragm Diaph Max Diaph Min Roof 4 14 19.32 270 0.29 2.03 2.03 2.06 4.12 2.06 Floor 10 10 65.52 655 0.71 4.92 6.96 2.06 13.97 6.99 0 0 0.00 0 0.00 0.00 6.96 0 0.00 0.00 0 0 0 0 0.00 0.00 6.96 0 0.00 0.00 Suml 84.84 1 926 1 RoojLevel Story Shear (kips) 2.0 Area Weight Mass Trib Area (ftA2) Line Shear Line Shear ftA2 psf kis Wall Line Roof Floor Hay Storage ULT (kis W/S (kips) Roof 1936 10 19.32 1 968 0 0 1.02 0.71 Roof Snow 0 0.00 2 968 0 0 1.02 0.71 Floor 12 0.00 A 968 0 0 1.02 0.71 Hay Storage 18 0.00 B 968 0 0 1.02 0.71 Exterior Wall 14 0.00 Interior Wall 9 0.00 Sum (kips) 79.32 Pg. 5 Floor Story Shear (kips) 4.9 Area Weight Mass Trib Area (ftA2) Line Shear . Line Shear ftA2 lbs kis Wall Line Roof Floor Hay Storage ULT (kips) W/S (kips) Roof 10 0.00 1 0 800 800 2.46 1.72 Roof Snow 0 0.00 2 0 800 800 2.46 1.72 Floor 1600 12 19.12 A 0 800 800 2.46 1.72 Hay Storage 1600 18 28.80 B 0 800 800 2.46 1.72 Exterior Wall 14 0.00 Interior Wall 9 0.00 Sum (kips) 47.92 (2) Storage Containers 17.60 Pg. 6 "ASCE710W.xls" Program Version 2.2 WIND LOADING ANALYSIS - Main Wind -Force Resisting System Per ASCE 7-10 Code for Enclosed or Partially Enclosed Buildings Using Method 2: Analytical Procedure Section 27 & 28 for Low -Rise Buildings Job Name: 1 Book Barn I Subject: I r Job Number: 15-045 Originator: Checker: Input Data: Wind Speed, V = 110 mph (Wind Map, Figure 26.5 -1A -C) Bldg. Classification = II (Table 1.5-1 Risk Category) Wind Exposure Category = C (Sect. 26.7) Ridge Height, hr = 26.00 ft. (hr >= he) Eave Height, he = 15.00 ft. (he <= hr) Building Width = 40.00 ft. (Normal to Building Ridge) Building Length = 40.00 ft. (Parallel to Building Ridge) Roof Type = Monoslo a (Gable or Monoslope) I Topo. Factor, Kzt = 1.00 (Sect. 26.8 & Figure 26.8-1) F-10" Direct. Factor, Kd = 0.85 (Table 26.6) Enclosed? (Y/N) Y (Sect. 26.2 & Table 26.11-1) Hurricane Region? N hr 0 h<=60' lesultinq Parameters and Coefficients: The Roof Angle, 0 = 26.57 deg. L Mean Roof Ht., h = 20.50 ft. (h = (hr+he)/2, for angle >10 deg.) Elevation Check Criteria for a Low -Rise Buildino: 1. Is h <= 60' ? F Yes, O.K. 2. Is h <= Lesser of L or B? Yes, O.K. External Pressure Coeff's., GCpf (Fig. 28.4-1): (For values, see following wind load tabulations.) Positive & Negative Internal Pressure Coefficients, GCpf (Table 26.11-1): +GCpi Coef. = 0.18 (positive internal pressure) -GCpi Coef. = 0.18 (negative internal pressure) If h < 15 then: Kh = 2.01 *(15/zg)^(2/a) (Table 28.3-1) If h >= 15 then: Kh = 2.01 * z/z ^(2/a) (Table 28.3-1) a = 9.50 1 (Table 26.9-1) zg = 900 (Table 26.9-1) Kh = 0.91 (Kh = Kz evaluated at z = h) Velocity Pressure: qz = 0.00256*Kz*Kzt*Kd *VA 2 (Sect. 28.3.2, Eq. 28.3-1) qh = 23.87 psf qh = 0.00256*Kh*Kzt*Kd *VA 2 (qz evaluated at z = h) Design Net External Wind Pressures (Sect. 28.4.1): p = qh*[(GCpf) - (+/-GCpi)] (psf, Eq. 28.4-1) Wall and Roof End Zone Widths'a' and'2*a' (Fig. 28.4-1): a = 4.00 ft. 2*a =1 8.00 ft. 1 of 3 1/14/2016 9:57 AM Pg. 7 "ASCE710W.xls" Program Version 2.2 MWFRS Wind Load for Load Case A MWFRS Wind Load for Load Case B Surface GCpf p = Net Pressures sf) Surface *GCpf p = Net Pressures sf w/ +GC i w/ -GCpi) w/ +GC i w/ -GCpi) Zone 1 0.55 8.82 17.42 Zone 1 -0.45 -15.04 -6.44 Zone 2 -0.10 -6.66 1.93 Zone 2 -0.69 -20.77 -12.17 Zone 3 -0.45 -14.97 -6.38 Zone 3 -0.37 -13.13 -4.54 Zone 4 -0.39 -13.62 -5.03 Zone 4 -0.45 -15.04 -6.44 Zone 5 --- --- --- Zone 5 0.40 5.25 13.84 Zone 6 --- --- --- Zone 6 -0.29 -11.22 -2.63 Zone 1 E 0.73 13.08 21.67 Zone 1 E -0.48 -15.75 -7.16 Zone 2E -0.19 -8.84 -0.25 Zone 2E _ -1.07 -29.84 -21.24 Zone 3E -0.58 -18.26 -9.67 Zone 3E -0.53 -16.95 -8.35 Zone 4E -0.53 -17.07 -8.47 Zone 4E -0.48 -15.75 -7.16 Zone 5E -- - --- Zone 5E 0.61 10.26 18.86 Zone 6E --- - -" --- Zone 6E -0.43 -14.56 -5.97 *Note: Use roof angle 9 = 0 degrees for Longitudinal Direction. For Case A when GCpf is neg. in Zones 2/2E: For Case B when GCpf is ne . in -Z nes 2/2E: Zones 2/2E dist. =F-20.00 ft. Zones 2/2E dist. =1 20.00 Ift. Remainder of roof Zones 2/2E extending to ridge line shall use roof Zones 3/3E pressure coefficients. MWFRS Wind Load for Load Case A, Torsional Case MWFRS Wind Load for Case B, Torsional Case Surface GCpf p = Net Pressure sf) Surface GCpf p = Net Pressure sf w/ +GC i w/ -GCpi) w/ +GC i w/ -GCpi) Zone 1T - - 2.21 4.35 Zone 1T --- -3.76 -1.61 . Zone 2T --- -1.67 0.48 Zone 2T --- -5.19 -3.04 Zone 3T --- -3.74 -1.59 1 Zone 3T --- -3.28 -1.13 Zone 4T --- -3.41 -1.26 Zone 4T --- -3.76 -1.61 Zone 5T --- --- --- Zone 5T --- 1.31 3.46 Zone 6T I --- --- Zone 6T --- -2.80 -0.66 Notes: 1. For Load Case A (Transverse), Load Case B (Longitudinal), and Torsional Cases: Zone 1 is windward wall for interior zone. Zone 1 E is windward wall for end zone. Zone 2 is windward roof for interior zone. Zone 2E is windward roof for end zone. Zone 3 is leeward roof for interior zone. Zone 3E is leeward roof for end zone. Zone 4 is leeward wall for interior zone. Zone 4E is leeward wall for end zone. Zones 5 and 6 are sidewalls. Zone 5E & 6E is sidewalls for e6d zone. Zone 1 T is windward wall for torsional case Zone 2T is windward roof for torsional case. Zone 3T is leeward roof for torsional case Zone 4T is leeward wall for torsional case. Zones 5T and 6T are sidewalls for torsional case. 2. (+) and (-) signs signify wind pressures acting toward & away from respective surfaces. 3. Building must be designed for all wind directions using the 8 load cases shown below. The load cases are applied to each building corner in turn as the reference corner. 4. Wind loads for torsional cases are 25% of respective transverse or longitudinal zone load values. Torsional loading shall apply to all 8 basic load cases applied at each reference corner. Exception: One-story buildings with "h" <= 30', buildings <= 2 stories framed with light frame construction, and buildings <=2 stories designed with flexible diaphragms need not be designed for torsional load cases. 5. Per Code Section 28.4.4, the minimum wind load for MWFRS shall not be less than 16 psf. 2 of 3 1/14/2016 9:57 AM M ASCE 7-10 Wind Loads - Low Rise Walls and Roofs (Section 28) Project: Book Barn Date: 1/14/2016 Comments: Units: lbs & feet (UNO) Wall Line ID A -B Roof Direction Transverse Trib Area p = Net Desi n Press. ( sf) = Net Design Press. (lbs) (w/ +GC i) (w/ -GC i) w/ +GC i) (w/ -GC i) to Ride (f -2) Zone 1 24 8.82 17.42 211.79 418.03 Zone 2 132 -6.66 1.93 -393.34 113.93 Zone 3 t32 -14.97 -6.38 883.75 376.48 Zone 4 24 -13.62 -5.03 326.89 120.65 Zone 5 --- --- Zone 6 --- --- Zone IE 16 13.08 21.67 209.21 346.70 Zone 2E 110 -8.84 -0.25 -434.81 12.07 Zone 3E 1.10 -18.26 -9.67 898.25 475.52 Zone 4E 16 -17.07 -8.47 273.06 135.57 Zone 5E --- --- Zone 6E --- -- Total (lbs) ULT 1974.81 1998.96 Total (lbs) WIS 1184.88 1199.37 Wall Line ID 7-2 Roof Direction Longitude Trib Area p = Net Design Press. (sf) p = Net Design Press. (Ibs) (w/ +GC i) (w/ -GC i) (w/ +GC i) (w/ -GC i) to Ride (ft^2) Zone 1 -15.04 -6.44 Zone 2 -20.77 -12.17 Zone 3 -13.13 -4.54 Zone 4 -15.04 - -6.44 Zone 5 108 5.25 13.84 567.15 1495.22 Zone 6 1.08 -11.22 -2.63 1211.64 283.58 Zone IE -15.75 -7.16 Zone 2E -29.84 -21.24 Zone 3E -16.95 -8.35 Zone 4E -15.75 -7.16 Zone 5E 32 10.26 18.86 328.45 603.43 Zone 6E 32 -14.56 -5.97 465.94 190.96 Total (lbs) ULT 2573.19 2573.19 Total (lbs) WIS 1543.91 1543.91 ME ASCE 7-10 Wind Loads - Low Rise Walls and Roofs (Section 28) Project: Book Barn Date: 1/14/2016 Comments: Units: lbs & feet (UNO) Wall Line ID A -B Floor Direction Transverse Trib Area p = Net Desi n Press. (sf) = Net Design Press. (lbs) (w/ +GC i) (w/ -GC i) (w/ +GC i) (w/ -GC i) to Ride (f A2) Zone 1 120 8.82 17.42 1058.96 2090.14 Zone 2 -6.66 1.93 Zone 3 -14.97 -6.38 ! Zone 4 120 -13.62 -5.03 1634.46 603.27 Zone 5 --- --- Zone 6 -- --- Zone IE 80 13.08 21.67 1046.05 1'1733.51 Zone 2E -8.84 -0.25 11 Zone 3E -18.26 -9.67 t Zone 4E 80 -17.07 -8.47 1365.29 677.83 Zone 5E --- f Zone 6E --- --- Total (lbs) ULT 5104.75 5104.75 Total (lbs) WIS 3062.85 3062.85 Wall Line ID 1-2 Floor Direction Longitude Trib Area p = Net Design Press. (sf) P=Net Desi n Press. (lbs) (w/ +GC i) (w/ -GC i) (w/ + i) ' (w/ -GC i) to Ride (ft -2) Zone 1 -15.04 -6.44 Zone 2 -20.77 -12.17 Zone 3 -13.13 -4.54 Zone -15.04 -6.44 Zone 5 120 5.25 13.84 630.17 1661.36 Zone 6 120 -11.22 -2.63 1346.27 315.08 Zone IE -15.75 -7.16 Zone 2E -29.84 -21.24 ' Zone 3E -16.95 -8.35 Zone 4E -15.75 -7.16 Zone 5E 80 10.26 18.86 821.13 1508.59 Zone 6E 80 -14.56 -5.97 1164.86 477.40 Total (lbs) ULT 3962.43 3962.43 Total (lbs) WIS 2377.46 2377.46 Pg. 10 Shear Force Summary Project: Book Barn Date: 1/14/2016 Comments: Units: kips & feet (UNO) Wall Line Seismic Shear Wind Shear Controls Roof Level 1 712 1544 Wind 2 712 1544 Wind A 712 1199 Wind B 712 1199 Wind Floor 1 1724 2377 Wind 2 1724 2377 Wind A 1724 3063 Wind B 1724 3063 Wind Pg. 11 Shear Wall Design CBC 2013 Project: Book Barn Date: 11/13/2015 Comments: Units: lbs & inches (UNO) Panel Thickness 318 Spec Grav Of Framing 0.5 Panel Orientation Short Dimension Across Studs Spec Grav Of Plywood C -D, C -C, APA Rated Shear Ply Nail Type 8d Fnd Sill Plate Grade DF -L Anchor Bold Diam. 112 AB in 2X Sill 983 lbs/bolt (see design) Stud Spacing 16 inches o.c. AB in 3X Sill 1146 lbs/bolt (see design) Floor Split Anchorage Adjusted Nail Nail Length Diam Embed Cd CD NDSValue Value lod 3 0.148 1.50 0.84 1.33 118 133 12d 3.25 0.148 1.75 0.99 1.33 118 155 16d 3.5 0.162 2.00 1.00 1.33 141 188 20d 4 0.192 2.50 1.00 1.33 170 226 30d 4.5 0.207 3.00 1.00 1.33 186 247 114,, Screw 0.25 2.00 1.00 1.33 220 293 381, Screw 0.375 3.00 1.00 1.33 400 532 A35 695 A34 515 Shear Wall Design Edge Nail Alowable Loads Sole Plate Fastening Rim Joist Fastening AB Spacing (ft) Spacing (in) note Seismic Wind Fastener Spacing (in) Fastener Spacing (in) 2X Sill 3X Sill 6- 164 164 12d 11 A.35 51, 6.00 6.00 6 260 260 12d 7 A35 32 3.78 4.41 4` 350 350 12d 5 A35 24, 2.81 3.27 4 1 380 532.5 12d 5 A35 22 1.29 3.02 3 1 490 685 12d 4 A35 17 1.00 2.34 2 1 640 895 16d 4 A.35 13 NG 1.79 44 1 760 1065 16d 3 A35 11 NG 1.51 33 1 980 1370 16d 2 A.35 9 NG 1.17 22 1 1280 1790 16d 2 A35 7 NG 0.90 1. Use 3X framing at adjacent panel edges and stagger nailing 1 N Shear Transfer Design CBC 2013 Project: Comments: Book Barn Date: Units: 1/14/2016 lbs & inches (UNO) Simpson A35 Simpson LPT4 Simpson H1 16d Sinkers 695 670 585 188.8 lbs lbs lbs lbs Seismic Overstrength Factor flo = 2.5 Wall Line ID Seismic Wall Load (kips) Wind Wall Load (kips) Line Length (ft) Diaphram Shear (lf) Connection Length (ft) Connection Spacing Force 16d Nails (If) (in) Spacing Hl (ft) Spacing A35 (ft) Spacing LPT4 (ft) Controaling Load Case Roof Level 1 0.71 1.54 40.00 38.60 12.00 128.66 17.61 4.55 5.40 5.21 Wind 2 0.71 1.54 40.00 38.60 12.00 128.66 17.61 4.55 5.40 5.21 Wind A 0.71 1.20 40.00 29.98 28.00 42.83 52.89 13.66 16.23 15.64 Wind B 0.71 1.20 40.00 29.98 28.00 42.83 52.89 13.66 16.23 15.64 Wind Floor Level 1 1.72 2.38 40.00 59.44 40.00 59.44 38.12 9.84 11.69 11.27 Wind 2 1.72 2.38 40.00 59.44 40.00 59.44 38.12 9.84 11.69 11.27 Wind A 1.72 3.06 40.00 76.57 40.00 76.57 29.59 7.64 9.08 8.75 Wind B 1.72 3.06 40.00 76.57 40.00 76.57 29.59 7.64 9.08 8.75 Wind 1 N Segmented Shear Wall Design ANSILAF&PA SDPWS-2008 Edition Project: Book Bam Date: 1/14/2016 Comments: Units: lbs & ft (UNO) Wall Wall Wall Fad Wall aspect Point Load Uplift from OTM Net Required Holdown Reqd Stem Line Load Wall Wall Height Length System A.B. Stress ratio Res extra end of wall above OTM Res Uplift Anchor or Width Wall Type (kips) Number Location (ft) (ft) T Location (If) enalt (IQ (lbs) (k) (ki -ft) (ki -fl) (kips)* Boll Strap (in) Wall Line ID: I - Roof HD Conn. Type (I=FND, 2=FTF): 2 Seismic I Ext 4 40.00 Stem Corner 18 1.0 65 2.8 50.9 -1.20 nia no lid re(jd nia 6` 0.71 Wind I Ext 4 40.0 Stem Corner 39 65 6.2 58.1 -1.30 n/a no ltd req'd nla 6° 1.54 Wall Line ID: 2 - Roof HD Conn. Type (I=FND, 2=FTF): 2 Seismic I Ext 4 40.00 Stem Comer 18 1.0 65 2.8 50.9 -1.20 n/a no lid ie(jd n/a fi= 0.71 Wind I Ext 4 . 40.00 Stem Comer 39 65 6.2 58.1 -1.30 n/a no lid n;q'd Na 6., 1.54 Wall Line ID: A - Roof HD Conn. Type (I=FND, 2=FTF): 2 Seismic I Ext 9 40.00 Stem Comer 18 1.0 6.4 53.0 -1.16 nia no lid resgil nia (i° 0.71 Wind I Ext 9 40.00 Stem Comer 30 10.8 60.5 -1.24 n/a no lid req'd n/a 6- 1.20 Wall Line ID: B - Roof HD Conn. Type (I=FND, 2=FTF): 2 Seismic I Ext 9 12.0 Stein Corner 30 1.0 3.2 4.8 -0.13 n/a no lid req'd Na 6- 0.71 _ Ext 9 12.0 Stem Corner 30 1.0 3.2 4.8 -0.13 n/3 no lid req it n/:i (i' Wind I Ext 9 12.0 Stem Corner 50 5.4 5.4 0.00 n/a no lid re(jd nia 6* 1.20 2 Ext 9 12.0 Stem Corner 50 5.4 5.4 0.00 n/a no lid req'd n/a 6° Joint No. 1 x 0.00000...8.004 A In.^2 n-8-0606-006 L n. I Ax h 8.00 Araints: 5.5 Joint No. Condition 1 Fixed 4 Fixed x -la (n.) Plot of Portal Frame Member No. I Eta A In.^2 12n.-4) L n. I Ax h 1 29000 5.5 i 4.1 8.0000 0.0000 1.0000 2 3 __2900D�: 29000, ___1:8 _i 5:5 4.4 4.1 .8A000 .f..._,A000 8.0000 ... 0.0000 ._.0.0000. 1.0000 Joint No. PX (kips) P kl c MZ n•k ,1 i .................... __............ _...... _....... 2 ............................I.........................._,_. . .............. 1.05 ........._.............. 3..................... ..... ...... _ 05......._ c 4 4.76 Distributed Loads: 1� O 2 O a O _-�X O Portal Frame Nomenclature CIL e/L bIL a2 P M we wb x or L Member Load Nomenclature Nom.-Pointloads 'orxromanlsafinember '- ends must be input as join loads. " 'FRAME.xIs" Program Version 1.1 Results: Support Reactions: Joint No. Ra (kip.) R (kip.) 64r Mac 4.76 4� -1.05 1 0.91 4.76 Member End Forces: Member No. Joint No. Axial Shear Moment nac 3.64 8.00 1 -0.91 ; 1.05 4.76 1 2 0.91 .1.05 3.64 .._.._................................................_.._ 2 ............__................_........_................................__............. 0.00 -0.91 -3.64 2 3 0.00 _..............................__....................._........_..................... 0.91 -3.64 ........__._3...._...._.................__._._..... 4 0.91 1.05 4.76 3 -0.91 -1.05 3.64 Member Maximum Moments: Member No. +M or •M M nac x or n. bIL wb (km.) I a I we D. b/L wb (kAL) I e/L we n.) +M(maxt 3.64 8.00 0.0000 i 0.0000 2 ....._ . ....................._...:. 3 Z-......_.... +M(max) ............ 3.64 1 0.00 -M(max) -3.64 8.00 0.0000 _. 3 __.._._...____ +M(max) ._. _._.._.._...........__._.._. 3.64 ': 8.00 -M(max) -4.76 ! 0.00 Joint Displacements: Joint No. Ax n. Ay On.)& bIL wb (km.) I a I we D. b/L wb (kAL) I e/L we n.) 1 0^0000 0.0000 i 0.0000 2 ....._ . ....................._...:. 3 0.9195 _..0..0606"-'--- 0.9195 0.0005 -0_3143. ....-0.0005 . -0.0005 -0.3143 4 0.0000 0.0000: 0.0000 Member Distributed Load #1 Distributed Load #2 Distributed Load #3 Distributed Load #4 Distributed Load #5 No. Load Direct. b/L wb (k/n.) e/L we (k/IL) b/L wb e/L we (km.i, b/L wb n.) e/L we (k41.) bIL wb (km.) I a I we D. b/L wb (kAL) I e/L we n.) I X -Global 2 X Projected ........................... . . ... .....::: ..._. .._.:::. ..-. .. .. .. ... ... _. ._ .:. _ _ 3 X Global i Point Loads: 1 of 1 11/16/2015 11:18 AM Moment #1 Moment #2 Moment #3 Moment #4 Member No. c/L M n -k sj dL I M (h -k! ) c/L M h- CIL M (fl -kips) 1 ........ ........ .... _..Z_.. ......... _...... .. 3 1 of 1 11/16/2015 11:18 AM SEQUOIA ENGINEERING Chad Ratzlaff Dimensions Depth 11.37 in Width 2.25 in Perimeter 31.62 in Geometric 50.16 in4 Area 5.409 int Ix 49.87 in4 Iy 4.068 in4 Ixy 3.648 in4 rx 3.036 in ry o.8673 in Sx+ 8.212 in3 Sx- 9.414 in3 Sy+ 3.164 in3 Sy- 4.22 in3 Xc o.964 in YC 5.297 in Principal I1 50.16 in4 I2 3.779 in4 a -4.526 deg r1 3.045 in 172 0.8359 in S1+ 8.149 in3 Si- 9.43 in3 S2+ 2.546 in3 S2- 3.037 in3 Polar Ip 53.94 in4 rp 3.158 in Torsion Plastic . ro 3.236 in H 0.9525 Xsc 0.2763 in Ysc 5.455 in Cw 27.71 in6 J 5.973 in4 B1 0.1878 in Section of door column Minimum Results Plastic . St. Venant -17.29 Ksi' Zx 13.96 in3 St. Venant'ryz -16.14 Ksi Zy 4.257 in3 Function Mb PNA X 0.6394 in Flexural Tyz PNA Y 5.269 in -16.43 Ksi Combined Tyz Minimum Results Shear Center St. Venant -17.29 Ksi' viz Va St. Venant'ryz -16.14 Ksi Warping -3.579 in Function Mb Flexural viz -0.0803 Ksi Flexural Tyz -0.8174 Ksi Combined viz -16.43 Ksi Combined Tyz -16.46 Ksi Resultant,r o.1088 Ksi Analysis Loads Shear Center System P o Va 1.05 K Vb o K Ma o K -ft Mb o K -ft T 4.76 K -ft Part Materials All ASTM A36 Pg. 15 11/16/2015 Door Column 's 6 FEA Mesh Nodes 1250 Elements 1047 Largest 0.2163 inz Element Maximum Results St. . Venant 17.8 Ksi viz St. Venant 1yz 16.29 Ksi Warping 5.591 inz Function Flexural viz 0.9943 Ksi Flexuralryz 0.7479 Ksi Combined viz 18.79 Ksi Combined ryz 16.53 Ksi Resultant T 18.83 Ksi E ShapeBuilder 8.00.0005 E www.iesweb.com Ai S Pg. 16 Element Analysis per ASIC 360-10 Project: Book Barn Date: 11/16/2015 Comments: Units: lbs & feet (UNO) Door End Column Geometry Fy 36 ksi E 29000 ksi Area 5.409 in^2 Aw 1 in A2 t 0.25 in h 2 in Ix 49.87 in^4 ly 4.068 in^4 Ixy 3.648 in^4 rx 3.036 in ry 0.8673 in Sx+ 8.212 in^3 Sx- 9.414 in^3 Sy+ 3.164 in^3 Sy- 4.22 in^3 Xc 0.964 in Xy 5.297 in Ip 53.94 in^4 rp 3.158 in Zx 13.96 in A3 Zy 4.257 in^3 PNA X 0.6394 PNA Y 5.269 Calculations Mn=Mp=Fy*Z Mn = 153.252 k -in M 59.52 k -in h/t 8 Kv 5 1.1(kvE/Fy)^0.5 69.81125 1.37(kvE/Fy)0.5 86.94674 Cv 1 G2-3 Vn 21.6 kips G2-1 f1v 1.5 Vn/92v 14.4 kips V 1.05 kips SEQUOIA ENGINEERING Chad Ratzlaff Dimensions Depth 14 in Width 3.in Perimeter 37.85 in Geom etric Area 3.649in2 Ix 106. in4 Iy 3.003 in4 Ixy -0.3413 in4 rx 5.389 in ry 0.9072 in Sx+ 13.61 in Sx- 17.05 in Sy+ 1.973 in3 Sy- 2.032 in Xc 1.478in Yc 6.213 in Principal I1 106. in4 I2 3.002 in4 a o.1899 deg r1 5.389 in r2 0.9071 in S1+ 13.6 in S1- 17.04 i n 3 S2+ 1.992 in S2- 2.005 in New window header Existing top beam Existing wall s .s New HSS beam flat - per plan 1.�Sin Lrjt�ll 4UV 19 Polar Ip 109• in4 Plastic FEA Mesh rp 5.465 in Zx 18.24 in Nodes 1895 Zy 2.678in3 Elements 1530 PNAX 1.461 in Largest 0.1459in2 MinimumRetq. PNAY 4.28in Element Warping inz Function Maximum Results Part Materials Warping 9.139in2 All ASTMA36 Function lAShapeBuilder 8.00.0005 E www.iesweb.com S Pg. 17 11/16/2015 new window hdr Torsion ro 5.511 in H 0.9831 Xsc 1.448 in Ysc 5.498 in CW 97.84 in 6 J 4.039 in4 B1 2.659 in Pg. 18 Element Analysis per ASIC 360-10 Project: Book Barn Date: 11/16/2015 Comments: Units: lbs & feet (UNO) New Wall Header Geometry Calculations Fy 36 ksi Mn = Mp = Fy*Z E 29000 ksi Mn = 96.408 k -in Area 3.649 in^2 M 22.05 k -in Aw 0.64 in A2 t 0.25 in h 8 in h/t 32 Kv 5 Ix 106 in^4 ly 3.003 in^4 1.1(kvE/Fy)^0.5 69.81125 NY 0.3413 in A4 1.37(kvE/Fy)0.5 86.94674 rx 5.389 in Cv 1 G2-3 ry 0.9072 in Sx+ 13.61 in^3 Vn 13.824 kips G2-1 Sx- 17.05 in^3 SZv 1.5 Sy+ 1.973.in^3 Vn/av 9.216 kips Sy- 2.032 in^3 V 8.4 kips XC 1.478 in Xy 6.213 in Ip 109 in^4 rp 5.465 in Zx 18.24 in^3 Zy 2.678 in^3 PNA X 1.451 PNA Y 4.28 SEQUOIA ENGINEERING Chad Ratzlaff Dimensions Depth 1.4in Width 12. in Perimeter 25.26 in Geom etric Area 1.003in2 Ix 0.2861 in4 Iy 11.86 in4 Ixy -0.2818 in4 rx 0.5341 in ry 3.438 in Sx+ 0.3707 in3 Sx- 0.4554 in3 Sy+ 1.969 in3 Sy- 1.983 in3 Xc 5.979 in Yc o.6282 in Principal I1 11.86 in4 I2 0.2792 in4 a 88.61 degli r1 3.439 in r2 0.5276in S1+ 1.989 in 3' Si- 1.966 in3 S2+ 0.3566 in3 S2- 0.361 in3 Pg. 19 11/16/2015 Side Wall r 1'-ci" unit length of wallsection , e .s ,E T S c 59(iin 6.02 in mon in Polar Ip 12.14 in4 Plastic rp 3.479111 zx 0.4894 in3 Zy 2.994 in3 PNA X 6. in Torsion ro 3.667 in H 0.9004 Xse 5.216 in Ysc 1.498in Cw 0.4633 in6 J 0.0025 in4 131 -1.601 in ShapeBuilder 8.00.0005 rE wwwaesweb.com t S PNA Y 0.552 in Minimum Results Warping -2.426in2 Fun cti on 1.25 K Flexural Txz 0.0021 Ksi Flexural Tyz -0.1373 Ksi aZ -1.21 Ksi Combined O.0021 Ksi Txz o K -ft Combined -0.1373 Ksi Tyz Resultant T 0.0026 Ksi Analysis Loads System Shear Center P 1.25 K Va 0.2153 K Vb o Ma o K -ft Mb o K -ft T o K -ft Part Materials Import 1 ASTMA36 UA Mesh Nodes 731 Elements 546 Largest 0.0401in2 Element Maximum Results Warping 1.515in2 Fu n cti on Flexural Txz 0.3563 Ksi Flexural Tyz 0.1453 Ksi az 4.194 Ksi Combined 0.3563 Ksi TXZ - Combined 0.1453 Ksi Tyz Resultant 0.3564 Ksi Pg. 20 Element Analysis per ASIC 360-10 Project: Comments: Book .Barn Date: 11/16/2015 Units: ]bs & feet (UNO) Wall in compression Geometry Calculations b 2.75 in b/t 34.375 t 0.08 in '1.49(E/Fy)' 42.28964 Ag 1.003 in^2 0.56(E/Fy)' 15.89409 Ix 0.2861 in^4 1.3(E/Fy)^( 36.897 ly 11.86 in^4 rx 0.5341 in Qs 0.518755 E7-54 ry 3.438 in i Xc 5.979 in Kx*I/rx 179.7416 Yc 0.6282 in 4.71(E/Qfy 185.6041 Cw 0.4633 in^6 J 0.0025 in^4 Fcr=Q(0.65 7.728416 kip E7-2 E 29000 ksi Fe 8.859321 kip E3-4 Fy 36 ksi Kx 1 Pn=Fcr 8 Al 7.751601 kip E7-1 Ky 1 SIC 1.67 Kz 1 Pn/SIc 4.641678 kip ; L 96 in P 1.2 kips kv 5 Aw 0.44 in^2 1.1(kvE/Fy; 69.81125 1.37(kvE/F 86.94674 Cv 1 G2-3 Vn 9.504 kips G2-1 SIV 1.5 Vn/SIv 6.336 kips (per unit length 1'-0") V 0.261305 kips/ft Worst case end wall (line A) SEQUOIA ENGINEERING Chad Ratzlaff Dimensions Depth 4.375 in Width 4.375 in Perimeter 16.84 in Geom etric Area 3.o85in2 Ix 8.863 in 4 Iy 8.863 in4 Ixy oin4 rx 1.695 in ry 1.695 in Sx+ 4.052 in Sx- 4.052 in Sy+ 4.052 in Sy- 4.052 in Xe 15.99 in Yc 18.35 in Principal II 8.863 in4 I2 8.863 in4 a o deg r1 1.695 in r2 1.695 in S1+ 4.052 in Si- 4.052 in S2+ 4.052 in S2- 4.052 in Pg. 21 11/16/2015 Top Beam at door end Polar Ip 17.73 in4 Plastic FEA Mesh rp 2.397 in Zx 4.79 in Nodes 754 Zy 4.79 in 3Elements 618 PNAX 15.99 in Largest 0.1234in2 Minimum Results PNAY 18.35 in Element Warping-0.2644-in2 Fu n cti on Maximum Results Part Materials Warping 0.2636in2 All ASTMA36 Function ShapeBuilder 8.00.0005 E www.iesweb.com I S Top Beam Torsion ro 2.397 in H 1. Xsc 15.99 in Ysc 18.35 in Cw 0.0234 in 6 J 14.31 in4 B1 -0.0004 in Pg. 22 Element Analysis per ASIC 360-10 Project: Book Barn Date: 11/16/2015 Comments: Units: lbs & feet (UNO) Door End Header Geometry Calculations Fy 36 ksi Mn = Mp = Fy*Z E 29000 ksi Mn = 172.44 k -in Area 3.085 in^2 M 2 k -in Aw 1 in^2 t 0.25 in h 2 in h/t 8 Kv 5 Ix 8.863 in^4 ly 8.863 in^4 1.1(kvE/Fy)^0.5 69.81125 NY 0 in^4 1.37(kvE/Fy)0.5 86.94674 rx 1.695 in Cv 1 G2-3 ry 1.695 in Sx+ 4.052 in^3 Vn 21.6 kips G2-1 Sx- 4.052 in^3 S2v 1.5 Sy+ 4.052 in^3 Vn/Ov 14.4 kips Sy- 4.052 in^3 V 1 kips Xc 15.99 in Xy 18.35 in Ip 17.73 in^4 rp 2.397 in Zx 4.79 in^3 Zy 4.79 in^3 PNA X 15.99 PNA Y 18.35 Pg. 23 Welded joint design; Description Geomet )oor end frame coonection seam to columns Weld profile; Box b (width) 0 4.367 inches d (depth) 4.367 linches Calculated weld section properties: NX NY AW SW(bot) SW(top) JW 2.18 2.18 17.47 25.43 25.43 111.04 Inspected ? Yes Electrode I E60XX 0.6 FU 36.00 ksi 0 1 2.000 Weld leg size 3/16" Allowable stress increase; 1.00 Weld capacity; Shear/tension 41.681 kips Bending 5.056 ft -kips 60.67 in -kips Twisting 26.966 ft -kips 323.59 in -kips Welded joint design; Description Geomet Vail Panel to top and bottom support Weld profile; Vertical I v b (width) 0.000 inches d (depth) 1.000 inches Calculated weld section properties: NX NY AW SW(bot) SW(top) JW 0.50 0.00 1.00 0.17 0.17 0.08 Inspected ? Electrode 0.6 FU 0 Weld leg size Allowable stress increase; Weld capacity; Shear/tension Bending Twisting Yes E60XX 36.00 ksi 2.000 1/8" 1.00 1.591 kips 0.022 ft -kips 0.059 ft -kips 0.27 in -kips 0.71 in -kips Pg. 24 iF 0 R T E" MEMBER REPORT Level, Floor Joist 1 piece(s) 117/8" T3I0 360 @ 16" OC 0 Overall Length: 40' 8' • 24' • 8' 11 E 0 All locations are measured from the outside face of left support (or left cantilever end).AII dimensions are horizontal.; Drawing is Conceptual 0 Design Results Actual (q1 Location Allowed Result dDF Load: Combination (Pattern) Member Reaction (Ibs) 2047 @ 8' 2460 (3.50") Passed (83%) 1.00 1.0 D + 1.0 L (Adj Spans) Shear (lbs) 1083 @ 8' 13/4" 1876 Passed (58%) 1.00 1.0 D + 1.0 L (Adj Spans) Moment (Ft -lbs) -3983 @ 8' 6180 Passed (64%) 1.00 1.0 D + 1.0 L (Adj Spans) Live Load Defl. (in) 0.515 @ 20' 0.800 Passed (U559) 1.0 D + 1.0 L (Alt Spans) Total Load Defl. (in) 0.613 @ 20' 1.200 Passed (L/470) 1.0 D + 1.0 L (Alt Spans) TJ -Pro" Rating 18 Any Passed -18 Deflection criteria: U. (L/360) and TL (L/240). Input total load span ratio deflection limit is below building code minimum value of L/240. This minimum value was used for design. Bracing (Lu): All compression edges (top and bottom) must be braced at 4' 1 1/4" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. -415 Itis uplift at support 1 1/4". Strapping or other restraint may be required. -415 Itis uplift at support 39' 8 1/4". Strapping or other restraint may be required. A structural analysis of the deck has not been performed. Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser Edge'" Panel (24" Span Rating) that is glued and nailed down. Additional considerations for the TJ -Pro— Rating include: None Supports Total Bearing I Available - — — Required Loads to Supports (lbs) Dead Floor Total Live Accessories 1 - Plate on steel - DF 3.50" 2.25" 1.75" -18 314/-397 314/-415 11/4 n Rim Board b - Plate on steel - DF 3.50" 3.50" 3.50" 338 1709 2047 Blocking 3 - Plate on steel - DF 3.50" 3.50" 3.50" 338 1709 2047 Blocking 4 - Plate on steel - DF 3.50" 2.25" 1.75" -18 314/-397 314/-415 11/4 n Rim Board --Rim Board is assumed to carry all loads applied directly above It, bypassing the member being designed. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Loads Location spacing Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 40' 16" 12.0 60.0 j Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports FSR -1153 and ESR -1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator Forte Software Operator Job Notes Chad Ratzlaff Sequoia Engineering (530) 591-7258 chadralzlaff@yahoo.com PASSED Pg. 25 System : Floor Member Type : Joist Building Use : Residential Building Code : IBC Design Methodology : ASD l SUSTAINABLE FORESTRY INITIATIVE 11/16/2015 11:06:15 AM Forte v5.0, Design Engine: V6.4.0.40 Floor Joist 4te Page 2 of 6 4FORTE' MEMBER REPORT Level, Flush Beam at Stairs 3 piece(s) 13/4" x 117/8" 1.9E Microllam® LVL Overall Length: 24'7" I l 1 I o �I it _ ti 24' O All locations are measured from the outside face of left support (or left cantilever end).AII dimensions are horizontal.; Drawing is Conceptual Desi n Results Actual (� Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs) 1584 @ 24-5" 11484 (3.50") Passed (14%) -- 1.0 D + 1.0 L (All Spans) Shear (lbs) 1447 @ 23'3 5/8" 11845 Passed (12%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft -lbs) 9529 @ 15-6" 26772 Passed (36%) 1.00 1.0 D + 1.0 L (Al Spans) Live Load Defl. (in) 0.524 @ 12' 6 13/16" 0.808 Passed (1-/555) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.728 @ 12'6 3/8" 1.212 Passed (L1400) 1.0 D + 1.0 L (All Spans) Deflection criteria: U. (L/360) and TL (L/240). Bracing (Lu): AII compression edges (top and bottom) must be braced at 24' 7" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Loads Bearing - Loads WS upports (Ibs) Supports Total Available Required Dead Floor Total Accessories 1 - Uniform (PSF) 0 to 4'6" Li 1 - Plate on steel - DF 3.50" 3.50" 1.50" 430 1092 1522 Blocking 2 - Plate on steel - DF 3.50" 3.50" 1.50" 440 1144 1584 Blocldng • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Loads Location Tributary Width Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 4'6" 1-4" 12.0 60.0 AG Loft Storage 2 - Uniform (PSF) 4' 7 3/16" to 15' 6" 8" 12.0 60.0 AG Loft Storage 3 - Uniform (PSF) 15'6" to 24'6" 1'4" 12.0 60.0 AG Loft Storage 4 - Point (lb) 4' 6" N/A 48 1 240 5 - Point (lb) 15' 6" N/A 96 1 480 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of Its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR -1153 and ESR -1387 and/or tested In accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator Forte Software Operator Job Notes Chad Ratzlaff Sequoia Engineering (530)591-7258 ch adratzl aff@yahoo.com PASSED Pg. 26 System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC Design Methodology: ASD QSUSTAINABLE FORESTRY INITIATIVE 11/16/2015 11:06:15 AM Forte v5.0, Design Engine: V6.4.0.40 Floor Joist.4te Page 3 of 6 MEMBER REPORT Level, Header at sliding doors .iIFORTE' 3 piece(s) 13/4" x 117/8" 1.9E Microllam® LVL Overall Length: 24'7" o o ,l 24' All locations are measured from the outside face of left support (or left cantilever end).AII dimensions are horizontal.; Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs) 2531 @ 2" 11484 (3.50") Passed (22%) 1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs) 2040 @ 1'313/8" 11845 Passed (17%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft -lbs) 13617 @ 12'3 1/2" 26772 Passed (51%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.344 @ 12' 3 1/2" 0.606 Passed (L/846) 1.0 D + 0.75 L + 0.75 Lr (All Spans) Total Load Defl.(in) 1.177 @ 12'3 1/2" 1 1.212 1 Passed (L/247) 1.0 D + 0.75 L + 0.75 Lr (All Spans) Deflection criteria: LL (L/480) and TL (L/240). Bracing (Lu): All compression edges (top and bottom) must be braced at 19' 1 15/16" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. • Blocldng Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Loads Bearing Loads to Supports (lbs) Supports Total Available Required Dead FlOof Roof Total Accessories Comments 1 - Uniform (PSF) Live Live 1 - Plate on steel - DF 3.50" 3.50" 1.50" 1793 492 492 2777 Blocldng 2 -Plate on steel - DF 3.50" 3.50" 1.50" 1785 492 492 2769 Blocldng • Blocldng Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Loads Location Tributary Width Dead (0.90) now Live (1.00) Roof Live (non -snow: L25) Comments 1 - Uniform (PSF) 0 to 24' 7" 8" 12.0 60.0 AG Loft Storage 2 - Uniform (PSF) 0 to 24' 7" 9' 10.0 - - Walls Load 3 - Uniform (PSF) 0 to 24' 7" 2' 15.0 20.0 Roof Loads 4 -Paint (PLF) 0 0 100.0 Sliding Door Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of Its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocldng Panels and Squash Blocks) are not designed by this software. Use of this software is not Intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer Is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR -1153 and ESR -1387 and/or tested In accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support information have been provided by Forte Software Operator Forte Software Operator Job Notes Chad Ratziatf Sequoia Engineering (530)591-7258 chadratz1aff@yahoo.com PASSED Pg. 27 System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC Design Methodology : ASD l SUSTAINABLE FORESTRY INITIATIVE 11/16/2015 11:06:15 AM Forte v5.0, Design Engine: V6.4.0.40 Floor Joist 4te Page 4 of 6 F 0 R T E MEMBER REPORT Level, Back wall Support Beam W411 piece(s) 6 x 12 Douglas Fir -Larch No. 1 Overall Length: 24' 10 1/2" All locations are measured from the outside face of left support (or left cantilever end).AII dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs) 4664 @ 12' 5 1/4" 12031 (3.50") Passed (39%) 1.0 D + 0.75 L + 0.75 Lr (All Spans) o 1865 @ 13' 6 1/2" 7168 Passed (26%) o Moment (Ft -lbs) -5346 @ 12' 5 1/4" 13638 Passed (39%) - Live Load Defl. (in) 0.019 @ 19' 3/16" 0.307 Passed (L/999+) �I Total Load Defl. (in) 0.071 @ 19'4 15/16" 1 0.614 1 Passed (L/999+) I -- 1 1.0 D + 0.75 L + 0.75 Lr (Alt Spans) 4 12 Blocking 12' 3.50" 0 1.50" 3743 614 614 All locations are measured from the outside face of left support (or left cantilever end).AII dimensions are horizontal.;Drawing is Conceptual Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs) 4664 @ 12' 5 1/4" 12031 (3.50") Passed (39%) 1.0 D + 0.75 L + 0.75 Lr (All Spans) Shear (lbs) 1865 @ 13' 6 1/2" 7168 Passed (26%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft -lbs) -5346 @ 12' 5 1/4" 13638 Passed (39%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.019 @ 19' 3/16" 0.307 Passed (L/999+) -- 1.0 D + 0.75 L + 0.75 Lr (Alt Spans) Total Load Defl. (in) 0.071 @ 19'4 15/16" 1 0.614 1 Passed (L/999+) I -- 1 1.0 D + 0.75 L + 0.75 Lr (Alt Spans) Deflection criteria: LL (1/480) and TL (L/240). Bracing (Lu): All compression edges (top and bottom) must be braced at 24' 10 1/2" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve member stability. Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Job Notes Bearing Dead ---- Loads to Supports (lbs)- (530) 591-7258 Loads Supports $u PP Total Available Required Dead Floor Roof Total Accessories 8" 12.0 60.0 AG Loft Storage Live Live 1 - Column Cap - steel 3.50" 3.50" 1.50" 1164 222/-31 206 1592/-31 Blocking 2 - Column Cap - steel 3.50" 3.50" 1.50" 3743 614 614 4971 None 3 - Column Cap - steel 3.50" 1 3.50" 1.50" 1164 222/-31 206 1592/-31 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. ------ Weyerhaeuser -- Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR -1153 and ESR -1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support Information have been provided by Forte Software Operator Forte Software Operator Job Notes Tributary Dead Floor Live Roof Live (530) 591-7258 Loads Location Width (0.90) (1.00) (non -snow: L25) Comments 1 - Uniform (PSF) 0 to 24' 10 1/2" 8" 12.0 60.0 AG Loft Storage Walls Load 2 - Uniform (PSF) 0 to 24' 10 1/2" 19' 10.0 - Roof Loads 3 - Uniform (PSF) 0 to 24' 10 1/2" 2' 15.0 20.0 ------ Weyerhaeuser -- Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR -1153 and ESR -1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support Information have been provided by Forte Software Operator Forte Software Operator Job Notes Chad Ratzlaff Sequoia Engineering (530) 591-7258 chadratzlaff@yalioo.com PASSED Pg. 28 System : Floor Member Type: Flush Beam Building Use : Residential Building Code : IBC Design Methodology : ASD 4 SUSTAINABLE FORESTRY INITIATIVE 11/16/2015 11:06:15 AM Forte v5.0, Design Engine: V6.4.0.40 Floor Joist 4fe Page 5 of 6 g MEMBER REPORT Level, Roof Rafter F O R T E 1 piece(s) 9 1/2" T3I@ 210 @ 24" OC Overall Sloped Length: 13'9 3/4" o o 12 6F ! — 2' 10' 51 9 All locations are measured from the outside face of left support (or left cantilever end).AII dimensions are horizontal.; Drawing is Conceptual I DPSi n Results Actual @ Location Allowed Result LDF Load: combination (Pattern) Member Reaction (lbs) 415 @ 2' 13/4" 1569 (1.75") Passed (26%) 1.25 1.0 D + 1.0 Lr (All Spans) Shear (lbs) 275 @ 2' 3 1/2" 1663 Passed (17%) 1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft -lbs) 619 @ 7' 1" 3750 Passed (17%) 1.25 1.0 D + 1.0 Lr (Alt Spans) Live Load Defl. (in) 0.058 @ 6' 115/8" 0.535 Passed (L/999+) -- 1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in) 0.082 @ 6' 11 13/16" 1 0.713 1 Passed (L/999+) I -- 1 1.0 D + 1.0 Lr (Alt Spans) Deflection criteria: LL (L/240) and TL (L/180). Overhang deflection criteria: U. (2LJ240) and TL (2L/180). Bracing (Lu): All compression edges (top and bottom) must be braced at 7' 19/16" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing Is required to achieve member stability. • Blocldng Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. • 2 Required Bearing Length / Required Bearing Length with Web Stiffeners PASSED Pg. 29 System : Roof Member Type : Joist Building Use : Residential Building Code : IBC Design Methodology : ASD Member Pitch: 6/12 Connector: Simpson Strong -Tie Connectors --Bearing — Loads toSupports (Ibs)---- - — - Supports Total Available - -Required Dead �e Total Accessories 1 - Birdsmouth - OF 3.50" 3.50" 1.75" 128 287 415 Web Stiffeners, Blocldng 2 - Hanger on 9 1/2" SPF beam 3.50" Hanger' 1.75"/_ 2 86 198 284 See note' • Blocldng Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. • 2 Required Bearing Length / Required Bearing Length with Web Stiffeners PASSED Pg. 29 System : Roof Member Type : Joist Building Use : Residential Building Code : IBC Design Methodology : ASD Member Pitch: 6/12 Connector: Simpson Strong -Tie Connectors Support I Model seat Length Top Nails Face Nails Member Nails Accessories 2 - Face Mount Hanger I LSSU2.1 3.50" N/A 9-10d common 7-10d x 1-1/2 Web Stiffeners Loads Location Spacing Dead (0.90) Roof Live (non -snow: Lill Comments 1 - Uniform (PSF) 0 to 12' 24" 8.0 20.0 Roof Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Refer to current Weyerhaeuser literature for installation details. (www.woodbywy.com) Accessories (Rim Board, Blocldng Panels and Squash Blocks) are not designed by this software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR -1153 and ESR -1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports refer to http://www.woodbywy.com/services/s_CodeReports.aspx. The product application, input design loads, dimensions and support Information have been provided by Forte Software Operator Forte Software Operator Job Notes Chad Ratziaii Sequoia Engineering (530)591-7258 chadratz1aff@yahoo.com 10, SUSTAINABLE FORESTRY INITIATIVE 11/116/2015 1 1:06:15 AM Forte v5.0, Design Engine: V6.4.0.40 Floor Joist 4te Page 6 of 6 Pg. 30 SEQUOIA ENGINEERING 11/16/2015 Chad Ratzlaff *Modular ratio (E/Ebase). Uncracked 3.63E-oo5 n 9.289 Area* 26o.9 inz Xc• o in Yc' o in Ix" 5304 in4 Iy" 5304 in4 w o in4 Sx+" 589.3 in3 Sx-' 589.3 in3 Sy+" 589.3 in3 Sy-" 589.3 in3 fcr 0.375 Ksi Mcr Top 18.42 K -ft Mcr 18.42 K -ft Bottom Mcr Right 18.42 K -ft Mcr Left 18.42 K -ft Concrete Shape Load P 5.3 K Mx 1.5 K -ft My o K -ft Analysis Parameters co 0.00300 Cu 0.0038o Whitney 0.85 Slice Points 50 Slice Count 10 Concrete Results Epsilon 3.63E-oo5 Ixcr 3254 in4 Iycr 4887 in4 Mo+x 19.24 K -ft Mo -x -23.15 K -ft Mo+y 19.86 K -ft Mo -y -19.89 K -ft NA Offset 5.324 in NA Alpha -o.o666 deg Po 569.9 K I ShapeBuilder 8.00.0005 i E www.iesweb.com 4 S Concrete Pilaster Concrete column at footings Bar Stresses Rebar Locations (in) Part Materials Bar 1 -0.3925 Ksi Bar 1 6.875,o, Round Concrete (F'c = 2.5 Bar 2 -o.8981 Ksi Bar 2 o,6.875 ksi) Bar 3 -0.3913 Ksi Bar 3 -6.875,o, Bars1(4x1) ASTM A615 Grade Bar 4 0.1142 Ksi Bar 4 o,-6.875 40 Base Material Concrete (F'c = 2.5 ksi) Pg. 31 "FOOTINGS.xls" Program Version 3.6 RECTANGULAR SPREAD FOOTING ANALYSIS For Assumed Rigid Footing with from 1 To 8 Piers (Load Points) Subjected to Uniaxial or Biaxial Eccentricity Job Name: I Book Barn T -Subject: lWorst Case FTG Job Number: 15-045 1 Originator: Checker: +Pz Input Data: +H '+Pz y Footing Data: + +MY Hx Footing Length, L = 3.000 tt. +Hx +Mx Footing Width, B = 3.000 ft. a 4 4 4 TTTTTzTT Footing Thickness, T = 1.500 ft. V Concrete Unit Wt., Tc 0.150 kcf x TD Soil Depth, D 0.500 ft. Soil Unit Wt., 7s = 0.120 kcf Pass. Press. Coef., Kp = 3.000 T Coef. of Base Friction, g = 0.200 I Uniform Surcharge, 0 = 0.000 ksf Pier/Loading Data: L Number of Piers = I Nomenclature Pier #1 xp (ft.) Yp (ft.) Lpx (ft.) Lpy (ft.) h (ft.) PZ (k) Hx (k) Hy (k) MX (ft -k) My (ft -k) 0.000 0.000 1.333 1.333 2.500 -5.30 0.53 0.00 0.00 0.00 FOOTING PLAN 1 of 2 1/14/2016 10:00 AM • 0 EPz = -8.43 kips ex = 0.25 ft. (<= u6) ey = 0.00 Overturnin Check: EMrx = _ N.A. ft -kips EMox = N.A. ft -kips FS(ot)x = _ N.A. Entry = 12.64 ft -kips EMoy = 2.13_ ft -kips FS(ot)y = 5.932 (>=1.5) Pass(x) _ Frict(x) = FS(slid)x = Passive(y) = Frict(y) = FS(slid)y = _ 2.03 _ 1.69 _ 6.964 kips kips (>=1.5) kips kips 2.03 1.69 _ N.A. EPz(down) _ -8.43 _ kips EPz(uplift) = 0.00 kips FS(uplift) = N.A. Bearina Lenat and % Be rina Area: Dist. x = N.A. ft. Dist. y = N.A. ft. _ Brg. Lx = 3.000 ft. Brg. Ly = 3.000 ft. %Brg. Area = 100.00 Biaxial Case =1 N.A. Pi ksf P2 = 1.405 _ kst P3 = 0.468 kst P4 - 0.468 ksf P3=0.468 k P2=1.405 ksf B P4=0.468 ksf L P1=1.405 ksf Kimura Net Soil Pressure: Pmax(net) = Pmax rosy-(D+T)*Ts Pmax(net) = 1.165 1 ksf Nomenclature for Biaxial Eccentricity: Case 1: For 3 Corners in Bearing (Dist. x > L and Dist. y > B) I Dist. x Case 2: For 2 Corners in Bearing (Dist. x > L and Dist. y <= B) Case 3: For 2 Corners in Bearing (Dist. x <= L and Dist. y > B) 1E Dist. x TI Line of zero pressure Pg. 32 "FOOTINGS.xls" Program Version 3.6 Pmax Dist. y Pmax Dist. y Brg. Ly2 Pmax Dist. y Case 4: For 1 Corner in Bearing (Dist. x <= L and Dist. y <= B) Dist. x Brq. Lx Pmax Dist. y Brg. Ly Line of zero pressure 2of2 1/14/2016 10:00 AM ZA-DyAt S--000'5 Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR Alternate Materials and Methods Request 13AIDM I S -o065 Name BOOK FAMILY FARM APN: 040-570-019 BP# ►31�TZ �' �S zal3 Pursuant to Section 17923 and 17951 of the California Health and Safety Code and the 2WF California Building Codes, a building department may approve the use of alternate materials and methods not specifically prescribed in the code. The Building Official may approve such an alternate, provided there is evidence that the alternate is found to be at least the equivalent of that prescribed by the code in suitability, strength, effectiveness, fire resistance, durability, safety, and sanitation. The Property Owner and/or Contractor shall defend, hold harmless and indemnify Butte County against all claims, suits, actions, costs, expenses (including but not limited to reasonable attorneys fees of County Counsel and/or counsel retained by County, expert fees, litigation costs, and investigation costs), damages, judgments or decrees by reason of any person's or persons' bodily injury, including death, or property being damaged due to the use and installation of the alternative material or method. Project: 40'X 40' AG BUILDING Project Address: 153 HEAVY HORSE LANE, DURHAM, CA Proposed Alternate: STEEL STORAGE CONTAINER Code Section(s): CBC 2013 SEC. 22, ASIC 360-10 Justification of Equivalence can include: manufacturer's approvals, testing, certifications, and technical data. For speck materials such as PEX that require special training include the installer's card. (Attach additional information as needed) See structural calculations for analysis of steel storage container elements (finite element analysis with AISC 360-10 verification) Owner Name: KEITH BOOK Signature: Date: I�^ "Contractor/Design Professional Name: CHAD RATZLAFF dba: SE UTA License # C64399 ENGINEE ` / r/5 Contractor/Design Professional Signature: Date: *Contractor information is required when a product requirespe ific training, for example PEX. In other cases the registered design professional or contra�f®rm ion is required. Date /J_-Z//S. NOV r V p1„OPMENT OLE copy 5A1>A V5 OZ)L)S— 7 County Center Drive CA 95965 PERMIT #BUTTE SERVICE -- (530) 5338-7601 Telephone (530) (530) 538-7785 Facsimile COUNTY DEVELOPMENT REVIEWED FOR www.buitecounty.net/dds CODE COMPLI CE www.butte-generalplan.net DATE I Z Z ADMINI TRA ION * BUILDING * ING Alternate Materials and Methods Request 13AIDM I S -o065 Name BOOK FAMILY FARM APN: 040-570-019 BP# ►31�TZ �' �S zal3 Pursuant to Section 17923 and 17951 of the California Health and Safety Code and the 2WF California Building Codes, a building department may approve the use of alternate materials and methods not specifically prescribed in the code. The Building Official may approve such an alternate, provided there is evidence that the alternate is found to be at least the equivalent of that prescribed by the code in suitability, strength, effectiveness, fire resistance, durability, safety, and sanitation. The Property Owner and/or Contractor shall defend, hold harmless and indemnify Butte County against all claims, suits, actions, costs, expenses (including but not limited to reasonable attorneys fees of County Counsel and/or counsel retained by County, expert fees, litigation costs, and investigation costs), damages, judgments or decrees by reason of any person's or persons' bodily injury, including death, or property being damaged due to the use and installation of the alternative material or method. Project: 40'X 40' AG BUILDING Project Address: 153 HEAVY HORSE LANE, DURHAM, CA Proposed Alternate: STEEL STORAGE CONTAINER Code Section(s): CBC 2013 SEC. 22, ASIC 360-10 Justification of Equivalence can include: manufacturer's approvals, testing, certifications, and technical data. For speck materials such as PEX that require special training include the installer's card. (Attach additional information as needed) See structural calculations for analysis of steel storage container elements (finite element analysis with AISC 360-10 verification) Owner Name: KEITH BOOK Signature: Date: I�^ "Contractor/Design Professional Name: CHAD RATZLAFF dba: SE UTA License # C64399 ENGINEE ` / r/5 Contractor/Design Professional Signature: Date: *Contractor information is required when a product requirespe ific training, for example PEX. In other cases the registered design professional or contra�f®rm ion is required. Date /J_-Z//S. NOV r V p1„OPMENT OLE copy U.S.DEPQRTMENTOFHOMELAND SECURITY ELEVATION CERTIFICATE FEDERAL EMERGENCY MANAGEMENT AGENCY OMB No. 1660-0008 'tVutionul Flood Insurance Program Important: Read the instructions on pages 1-9. Expiration Date: July 31, 2015 SECTION A - PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Keith W. & Maxine Joy Book Policy Number: A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Company NAIC Number: 153 Heavy Horse Lane BUTTE City Durham State CA ZIP Code 95938 COUNTY A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) JAN 15 2016 Assessor's Parcel Number 040-570-019 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Non -Residential DEVELOPMENT A5. Latitude/Longitude: Lat. 390 37'48.2" Long. -1210 42'25.0" Horizontal Datum: ❑ NAD 1927�ENeVP@ES A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 5 A8. For a building with a crawlspace or enclosure(s): A9. For a building with an attached garage: a) Square footage of crawlspace or enclosure(s) N/A sq ft a) Square footage of attached garage N/A sq tt b) Number of permanent flood openings in the crawlspace b) Number of permanent flood openings in the attached garage or enclosure(s) within 1.0 foot above adjacent grade N/A within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b N/A sq in c) Total net area of flood openings in A9.b N/A sq in d) Engineered flood openings? ❑ Yes ® No d) Engineered flood openings?. ❑ Yes ® No SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State Butte County 060017 Butte County (Unincorporated Area) CA B4. Map/Panel Number B5. Suffix B6. FIRM Index Date B7. FIRM Panel 68. Flood B9. Base Flood Elevation(s) (Zone 06007CO540 E 01/06/11 Effective/Revised Date Zone(s) AO, use base flood depth) y���^`��' 01/06/11 A 174.0 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. ❑ FIS Profile ❑ FIRM ❑ Community Determined ® Other/Source: See Section D comments B11. Indicate elevation datum used for BFE in Item B9: ® NGVD 1929 ❑ NAVD 1988 ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No Designation Date: ❑ CBRS ❑ OPA SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) Cl. Building elevations are based on: ® Construction Drawings' ❑ Building Under Construction' ❑ Finished Construction 'A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations - Zones Ai -A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, ARIA, AR/AE, AR/Al-A30, AR/AH, AR/AO. Complete I ems C . -h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters. � Benchmark Utilized: See attached Vertical Datum: NAVD 1929 ¢ cc u Indicate elevation datum used for the elevations in items a) through h) below. ® NGVD 1929 ❑ NAVD 1988 ❑ Other/Source: 11' Datum used for building elevations must be the same as that used for the BFE. i-- I I m a) Top of bottom floor (including basement, crawlspace, or enclosure floor) b) Top of the next higher floor c) Bottom of the lowest horizontal structural member (V Zones only) d) Attached garage (top of slab) e) Lowest elevation of machinery or equipment servicing the building (Describe type of equipment and location in Comments) f) Lowest adjacent (finished) grade next to building (LAG) g) Highest adjacent (finished) grade next to building (HAG) h) Lowest adjacent grade at lowest elevation of deck or stairs, including structural support 174.10 182.70 N/A. N/A. N/A. 171.7 172.2 172.00 Check the measurem ® feet ® feet ❑ feet ❑ feet ❑ feet ® feet ❑ ® feet ❑ ® feet ❑ SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION 2 25 This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation M o -- information. 1 certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. ® Check here if comments are on back of form. Were latitude and longitude in Section A by a provided provided ® Check here if attachments. licensed land surveyor? ® Yes El No y���^`��' SEAL HERE a;U , NO. 33381 .- ST C/V�L\Q, 9rFOF CAl�FO�� Certifier's Name Bruce A. Nash License Number 33381 Title Principal Engineer Company Name Rolls, Anderson & Rolls Address 115 Yellowstone Drive City Chico State CA ZIP Code 95973 Signature 4. NAs,f- Date 01-13-16 Telephone (530) 895-1422 FEMA Form 086-0-33 (7/12) See reverse side for continuation. Replaces all previous editions. ELEVATION CERTIFICATE, page 2 =a IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number: 153 Heavy Horse Lane City Durham State CA ZIP Code 95938 Company NAIC Number: SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Comments (1) This Elevation Certificate is for a two-story agricultural building elevated on piers; (2) latitude and longitude taken from Google, and (3) see Attachment.1 and Attachment 2. Signature Date 01-13-16 SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1 -E5. If the Certificate is intended to support a LOMA or LOMR-F request, complete Sections A, B, and C. For Items E1 -E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawlspace, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6-9 with permanent flood openings provided in Section A Items 8 and/or 9 (see pages 8-9 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and/or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA -issued or community -issued BFE) or Zone AO must sign here. The statements in Sections A, B, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments P, -� ❑ Check here if attachments. SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8 -G10. In Puerto Rico only, enter meters. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2:,0 A community official completed Section E for a building located in Zone A (without a FEMA -issued or community -issued BFE) or Zone AO. G3.'❑ The following information (Items G4 -G10) is provided for community floodplain management purposes. G4.- Permit Number. G5. Date Permit Issued G6. Date Certificate Of Compliance/Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: ❑ feet ❑ meters Datum 1 G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters Datum G10. Community's design flood elevation: ❑ feet ❑ meters Datum Local Official's Name Title 1{ Community Name Telephone Signature Date Comments ❑ Check here if attachments. FEMA Form 086-0-33 (7/12) Replaces all previous editions. �f. ELEVATION CERTIFICATE ATTACHMENT 1 BUILDING STREET ADDRESS: 153 Heavy Horse Lane Durham, CA 95938 SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED): C.2 Benchmark of Origin: Butte County Benchmark No. 271, USGS — Stamped (W 57 1948) standard tablet. Location: Durham, 1.1 miles south and 5.5 miles east of, 24 feet north of gate, 27 feet west of road in line with fence west. Standard tablet set in a concrete post stamped "W 57 1948". Elevation = 185.451 feet (NAVD 1929 Datum). Temporary Benchmark Description: 5/8" rebar with plastic cap marked R.C.E. 29113 at the northwest corner of Parcel 2 as shown on that certain Parcel Map recorded in the office of the County Recorder of the County of Butte, State of California, in Book 159 at page 82. Elevation = 172.18 feet (NAVD 1929 Datum). SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED): 3. To determine the 100 -year Base Flood Elevation at the proposed building, Contour Interpolation of the Simplified Methods contained in FEMA Publication 265 was used. The approximate Zone A floodplain boundaries shown ori FIRM Number 060000540E were superimposed onto the Hamlin Canyon, California quadrangle map. Interpolation of the 100 -year flood elevation utilizing ground contour elevations and adding one-half of the map contour interval to the lowest determined water -surface elevation indicates a 100 -year Base Flood Elevation of approximately 174.0 feet (NAVD 1929 Datum) at the site of the proposed building. PARCEL 3 159 PM 82 A.P.N. 040-570-019 00 PROPOSED SUPERIMPOSED ZONE A AG BUILDING BOUNDARY LINE EXISTING HOME Q 171.69 X71.67 X72.38 GjV 172.16 172.17 172.0 ZONE A x x x 5172.18 PARCEL 2 159 PM 82- A.P.N. 2-A.P.N. 040-570-018 i i EXISTING / HOME / / PROJECT BENCHMARK 5/8" REBAR AND PLASTIC CAP MARKED RCE 29113 ELEV. = 172.18 LEGEND 172.38 EXISTING GROUND SPOT ELEVATION x (NGVD29 DATUM) EXISTING PROPERTY LINE I I EHOMEG PARCEL 1 159 PM 82 A.P.N. 040-570-017 ZONE X I? FESS/ON9 QUO JG� A. C�o m z 5 60*vC_.4..v ,',�^T d No. 33381 * CIVIC of Ca��to��� ATTACHMENT 2 FLOOD ELEVATION CERTIFICATE FOR BOOK FAMILY RAR ROLLS ANDERSON & ROLLS CIVIL ENGINEERS 115 YEUOWME ORWE • CHICO,'CAUFORNIA 95979-5811 TELEPHONE 590-895-1422 NOVEMBER, 2015 15145 SHEET 1 OF 1 n ■ • f= CIVIL & STRUCTURAL January 14, 2016 To Whom It May Concern: This letter is in response to the plan review for the above referenced project from your office on November 20, 2015. The following is a list of corrections to the plans per comments in your letter. Please accept my responses as follows Non -Structural Comments: 1. Sheet S1 has been modified to reference the 2013 building codes. 2. See the provided Alternate Materials and Methods Request form. 3. Owner has provided the Butte County Fire Department form. 4. Site plan has been modified, Sheet Al. 5. Erosion control measure notes have been added to the site plan Sheet Al. 6. Scope of work has been added to Sheet Al. 7. The site plan on Sheet Al has been modified to indicate that the ground adjacent to the structure will'be sloped 5% away. 8. See Electrical Note 5 on Sheet A2. 9. See Electrical Note 7 on Sheet A2. 10. See Electrical Note 8 on Sheet A2. 11. See Electrical Note 10 on Sheet A2. Structural Comments: 1. This is an agricultural building classified as a utility building. The attic space is uninhabitable and would fall under section 25 of Table 1607.1 of the 2013CBC. Due to the attic space being serviced by a fixed staircase, the live load would be subject to footnote V and thus the live load would be 30 psf. However, using engineering judgment and the notion that the area may be used to store agricultural products, I conservatively used a design live load of 60 psf. This structure is not a Storage Warehouse (Section 31) or Manufacturing (Section 20), so the heavier live loads were not used for this project. 2. Wind loads and calculations have been amended, no changes required to plan. 3. Loads and calculations have been amended, no changes required to plan. Flood Zone Comments: 1 2 3 Flood Elevation information has been added to the plans. By others. Notes have been added to the plans. Chad Ratzlaff, P.E., M.ASCE 467 East 2ntl Ave, Chico, CA 95926 (530) 591-7258 v Fi L chad@sequoiacivil.com BUTTE Butte County Building Department COUNTY 7 County Center Drive JAN 1 5 Y2016 Oroville, CA 95965 RE: Book Family Farm Ag Building DEVELOPMENT APN: 040-570-019 SERVICES 81� VANS Building Permit No.: B15-2875 January 14, 2016 To Whom It May Concern: This letter is in response to the plan review for the above referenced project from your office on November 20, 2015. The following is a list of corrections to the plans per comments in your letter. Please accept my responses as follows Non -Structural Comments: 1. Sheet S1 has been modified to reference the 2013 building codes. 2. See the provided Alternate Materials and Methods Request form. 3. Owner has provided the Butte County Fire Department form. 4. Site plan has been modified, Sheet Al. 5. Erosion control measure notes have been added to the site plan Sheet Al. 6. Scope of work has been added to Sheet Al. 7. The site plan on Sheet Al has been modified to indicate that the ground adjacent to the structure will'be sloped 5% away. 8. See Electrical Note 5 on Sheet A2. 9. See Electrical Note 7 on Sheet A2. 10. See Electrical Note 8 on Sheet A2. 11. See Electrical Note 10 on Sheet A2. Structural Comments: 1. This is an agricultural building classified as a utility building. The attic space is uninhabitable and would fall under section 25 of Table 1607.1 of the 2013CBC. Due to the attic space being serviced by a fixed staircase, the live load would be subject to footnote V and thus the live load would be 30 psf. However, using engineering judgment and the notion that the area may be used to store agricultural products, I conservatively used a design live load of 60 psf. This structure is not a Storage Warehouse (Section 31) or Manufacturing (Section 20), so the heavier live loads were not used for this project. 2. Wind loads and calculations have been amended, no changes required to plan. 3. Loads and calculations have been amended, no changes required to plan. Flood Zone Comments: 1 2 3 Flood Elevation information has been added to the plans. By others. Notes have been added to the plans. Chad Ratzlaff, P.E., M.ASCE 467 East 2ntl Ave, Chico, CA 95926 (530) 591-7258 v Fi L chad@sequoiacivil.com 9. Exterior outdoor lights, shall be High Efficacy luminaries or Low Efficacy (incandescent) luminaries controlled by a manual-on/off switch with a photocell and motion sensor. Refer to the Mandatory Measures for Residential Lighting Measures attached to the California Energy Commission, Mandatory Measures, form MF - IR. 10. Fixtures, lamp holders and receptacles outlets shall be securely supported. A fixture that weighs more than 6 pounds or exceeds 16 inches in any dimension shall not be supported by the screw shell of a lamp holder per 2013 CEC Art. 410.30 (a). Outlet boxes shall not be used as the sole support for ceiling (paddle) fans per 2013 CEC Art. 314.27 (A) & (D). 11. Electrical panel and sub -panels grounding shall comply 2013 CEC Article 250-32. Provide separate grounding wire to each panel from main electrical service entrance panel. STRUCTURAL COMMENTS: 1. The structural calculations page 2 indicate a live load of 60 psf for "AG Storage". Please confirm 60 psf is adequate and indicate how this load was determined. Storage areas are typically classified as light storage (125 psf) or heavy storage (250 psf) in accordance with CBC T.1607.1. 2. The wind loads for wall lines A and B on page 8 of the structural calculations appear to be incorrect. Appears total ULT wind load along these lines should be 1998.75#, not 1863.39#. Please verify wind loads are correct. 3. Please clarify wind pressure calculations for wall lines 1 and 2 (load case B). Why are the wind pressures calculated based on pressures acting on Fig. 28.4-1 surfaces 1, 4, 1E, and 4E only? FLOOD ZONE COMMENTS: 1. Please reference the flood elevation certificate on the plans and show all requirements including floor elevations, elevation of any machinery or equipment, stem wall heights, flood resistant materials, flood venting, etc. on the plans. 2. Please revise the FEMA flood elevation certificate to show elevations required in Section C2 a), b), and h). 3. Please indicate in a prominent location on the plans that a building under construction flood elevation certificate is required prior to the frame inspection and a finished construction flood elevation certificate is required prior to final approval of the structure. (Butte County Code Chapter 26, Ordinance # 404 1) The Department of Development Services is currently open to the public from 8:00 am to 3:00 pm. If you wish to discuss these plan check comments, please call during our business hours or contact us by e-mail at the address below. Permit status can be tracked by logging on to http:,/-,vNvNv.buttecoujitv.n.et/dds and clicking Building Permits Status. Carl Nelson Philo Hunt, P.E. Plans Examiner Plan Check Engineer (530) 538-2875 (530) 538-2130 csnelsoill.' buttecountv.net ph:unt'dbbuttecounty.net Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Office (530) 538-7785 Fax www.buttecounty.net December 4, 2015 Keith Book 153 Heavy Horse Ln Durham, CA 95938 Assessor Parcel Number: 040-570-019 Building Permit Number: B15-2875 Plan Check #1 Description: As -built Ag building in flood zone A Occupancy Classification: U Construction Type: V -B Stories: 2 Fire Sprinklers: No Building Total Area: U @ 3200 SQ FT Flood Zone: A per 06007CO540 E F.I.R.M. dated January 6, 2011 Thank you for submitting permits for your building project. The permit documents have been reviewed and comments are listed below. Please respond in writing to each comment. Complete and clear responses will expedite the re -check and approval of this project. Please provide two revised plan sets with your response. NON-STRUCTURAL COMMENTS: 1. Please revise 2010 code references on sheet A2 of the plans to reference the 2013 codes. 2. Obtain approval from the Butte County Building Division Manager for the Alternate Materials and Methods Request to use shipping containers (permit number BADM15-0005). 3. Please contact the Butte County Fire Department to determine their requirements for the proposed structure. Butte County Fire is located at 176 Nelson Avenue in Oroville and their phone number is 530-538-7888. 4. Please provide a complete site plan showing all items specified on the attached Site Plan Requirements. 5. Please specify erosion control measures on the site plan. See attached erosion control handout. 6. Please provide a Scope of Work on the plans. 7. Please specify the ground immediately adjacent to the foundation shall be sloped away from the building at a slope of not less than 6 -inches within the first 10 -feet (5% slope). 2013 CRC Section R401.3. 8. Please specify GFCI protected receptacles. Specify outdoor WP/GFCI protected receptacles at the exterior. 2013 CEC Art. 210.52 (E)(1) & 210.8.