Loading...
HomeMy WebLinkAboutB15-2984 000-000-000i C7 450'-0" I I I ------------------------- GENERAL _.__._ _. - GENERAL NOTES A. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE CALIFORNIA BUILDING CODE (2013 CBC), ALL LOCAL BUILDING ORDINANCES, 2013 CRC, 2013 CMC, 2013 CPC, 2013 CEC, 2013 CEnC, 2013 CalGreen AND 2013 PMC OR AS SPECIFICALLY NOTED ON THESE PLANS AND CALCULATIONS, WITH THE MOST STRINGENT CONDITION GOVERNING. IT IS THE RESPONSIBILITY OF THE CONTRACTOR/BUILDER TO BE FAMILIAR WITH AND COMPLY WITH THE REQUIREMENTS AS STATED IN ALL APPLICABLE CODES AND GOVERNING LOCAL BUILDING ORDINANCES. B. IF ANY CHANGES ARE MADE FROM THESE PLANS AND CALCULATIONS, THE ENGINEER OF RECORD, SHALL BE NOTIFIED PRIOR TO MAKING SUCH CHANGES, AND THE NECESSARY CERTIFIED REVISED PLANS AND CALCULATIONS OBTAINED. IF SUCH CHANGES ARE MADE WITHOUT THE NECESSARY APPROVAL OF THE ENGINEER, THEN THE ENGINEER OF ASSUMES NO RESPONSIBILITY FOR THE ENTIRE STRUCTURE OR ANY PORTION THEREOF AND SHALL BE HELD HARMLESS FROM ANY RESULTING CLAIMS OR DAMAGES. C. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON THESE PLANS BEFORE COMMENCING WORK, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES FOUND. D. THIS STRUCTURAL DESIGN IS BASED ON A COMPLETED STRUCTURE AS PER THE PLANS AND CALCULATIONS. THE ENGINEER OF RECORD SHALL NOT BE HELD RESPONSIBLE FOR, AND SHALL BE HELD HARMLESS FROM ANY DAMAGE RESULTING TO A STRUCTURE DUE TO LOADING CONDITIONS EXCEEDING THOSE FOR WHICH THE STRUCTURE HAS BEEN DESIGNED, OR DUE TO 'ACTS OF GOD" E. GRADE LINES AS SHOWN ON PLOT MAPS AND ELEVATION DRAWINGS ARE THE RESPONSIBILITY OF THE CLIENT, UNLESS A FIELD INSPECTION OF SUCH IS SPECIFICALLY REQUESTED. THE ENGINEER OF RECORD ASSUMES NO RESPONSIBILITY FOR DAMAGE TO OR CLAIMS RESULTING FROM ADDITIONAL CONSTRUCTION COSTS OF ANY STRUCTURES FOR WHICH THE CLIENT, DESIGNER, ARCHITECT, SURVEYOR OR ANY OTHER PARTY HAS MISREPRESENTED THE RELATIVE POSITION OF THE STRUCTURE TO THE NATURAL AND FINISHED GRADES OF THE BUILDING SITE. G. EXISTING CONDITIONS DEPICTED ON THESE DRAWINGS ARE TO BE FIELD VERIFIED BY THE CONTRACTOR, AS THEY ARE UNCOVERED DURING CONSTRUCTION. IN THE EVENT EXISTING CONDITIONS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY AND AWAIT FURTHER INSTRUCTIONS BEFORE PROCEEDING WITH CONSTRUCTION. H. THE CONTRACT STRUCTURAL DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE INDICATED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKERS, AND OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT NOT BE LIMITED TO, BRACING, SHORING FOR CONSTRUCTION EQUIPMENT, SHORING FOR THE BUILDING, FORMS AND SCAFFOLDING, AND SHORING OF RETAINING WALLS. I. IN NO CASE SHALL DIMENSIONS BE SCALED FROM DRAWINGS AND/OR DETAILS J. SPECIAL INSPECTION IS NOT REQUIRED. II. TIMBER A. ALL JOISTS, RAFTERS, AND LIGHT FRAMING MEMBERS ARE TO BE DOUGLAS FIR #2 OR BETTER FOR 4X AND SMALLER, AND DOUGLAS FIR #1 OR BETTER FOR 6X AND LARGER UNLESS SPECIFIED OTHERWISE. B. ALL STUDS 8 FOOT AND UNDER ARE TO BE OF STANDARD GRADE OR BETTER UNLESS SPECIFIED OTHERWISE. ALL STUDS GREATER THAN 8 FOOT SHALL BE DOUGLAS FIR #2 OR BETTER. C. ALL LVL'S SHALL BE 1.9E OR GREATER. D. ALL STUD WALLS ARE TO HAVE DOUBLE TOP PLATES OF THE SAME DIMENSION AS THE STUDS. PLATES ARE TO BE LAPPED A MINIMUM OF 48" BETWEEN SPLICES AND SHALL BE CONNECTED TOGETHER WITH A MINIMUM OF 16-16D NAILS UNLESS SPECIFIED OTHERWISE. E. ALL JOISTS AND RAFTERS ARE TO BE SOLID BLOCKED OR CROSS -BRIDGED OVERALL SUPPORT WALLS OR GIRDERS, OR AT A MAXIMUM SPACING PER CBC. F. ALL BUILT-UP, LAMINATED DOUBLE OR MULTIPLE 2X JOISTS AND BEAMS SHALL BE NAILED TOGETHER WITH 16D NAILS AT 12' O.C. BOTH TOP AND BOTTOM OF MEMBER STAGGERED WITH 3-16D NAILS AT ENDS AND AT SPLICES UNLESS SPECIFIED OTHERWISE. — _—_ N45----" W (999.96') WELL (E) BUILDING T/ AREA OF PROPOSED SCOPE OF WORK — ---- - --—-- -- —-- — — 60T_�/—LEACH FIELD SEPTIC TANK o Fr i ESIDEN i O� �o a S ITE PLAN SCALE: 1" = 60'-0" GENERAL NOTES G. ALL HEADERS AT EXTERIOR WALLS AND AT ROOF BEARING WALLS SHALL BE BEARING VII. CONCRETE AND MASONRY ON AT LEAST ONE STUD TRIMMER AND ONE FULL HEIGHT KING STUD EACH SIDE OF & SHEET INDEX OPENING UNLESS OTHERWISE INDICATED ON PLANS. A. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 A.2 DAYS. H. ALL PARTITION WALLS SHALL HAVE DOUBLE JOISTS OR SOLID BLOCKING DIRECTLY FOUNDATION & FLOOR FRAMING PLANS BELOW THE PARTITION. C. ALL REINFORCING STEEL SHALL BE GRADE 40 DEFORMED BARS, 40,000 PSI YIELD A.5 STRENGTH OR GREATER. ALL SPLICES SHALL LAP A MINIMUM OF 40 BAR I. STRESS INCREASES OF 15% FOR SNOW LOADS, 25% FOR ROOF LOADS, AND 33% FOR DIAMETERS. WIND OR SEISMIC LOADS, AS ALLOWED FOR BY THE CBC, HAVE BEEN USED IN THESE CALCULATIONS, EXCEPT WHERE LOCAL BUILDING CODES PROHIBIT SUCH INCREASES. VIII. FOUNDATIONS J. IN NO INSTANCE SHALL A STUD WALL BE USED AS A RETAINING WALL, I.E., TO A. ALL FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED SOIL. RESIST LATERAL PRESSURE DUE TO EARTH BACKFILL, OR WATER OR SNOW BUILD-UP AGAINST THE WALL. IN THE CASE OF SNOW BUILD-UP AGAINST A STUD WALL, IT B. ALL PIERS AND FOOTINGS NOT IN ENCLOSED SPACE OR AT THE PERIMETER OF THE SHALL BE THE RESPONSIBILITY OF THE OWNER TO REMOVE SUCH SNOW OR CREATE A STRUCTURE, OR IN UNHEATED AREAS, SHALL BE SET TO A DEPTH BELOW GRAL)E PER GAP BETWEEN THE SNOW AND THE WALL. THE ENGINEER 15 NOT RESPONSIBLE FOR CBC 1805.2, OR TO THE FROST DEPTH PER THE LOCAL BUILDING OFFICIAL, AND SHALL BE HELD HARMLESS FOR DAMAGES AND CLAIMS RESULTING FROM WHICHEVER IS DEEPER, UNLESS SPECIFIED OTHERWISE. ALL PERIMETER MOVEMENT OF OR DAMAGE TO THE STRUCTURE DUE TO LATERAL PRESSURE OF SNOW, FOUNDATIONS AND EXTERIOR PIERS SHALL HAVE A MINIMUM 2% GRADE FALL AWAY WATER, OR EARTH AGAINST THE STUDWALL. FOR 5' FROM CONCRETE OR AS SPECIFIED. K. ALL FRAMING LUMBER SHALL HAVE MAXIMUM 19% MOISTURE CONTENT AT TIME C. UNLESS SPECIFIED OTHERWISE, AN ASSUMED BASIC ALLOWABLE SOIL BEARING OF INSTALLATION AND FRAMING TO BE CHECKED FOR MOISTURE AND BE WITHIN MINIMUM PRESSURE OF 1500 PSF HAS BEEN ASSUMED. IF ANY QUESTIONABLE COMPLIANCE PRIOR TO INSULATION AND/OR ENCLOSURE PER CGB5 SECTION 4.505. SOIL IS ENCOUNTERED DURING EXCAVATION, THE ENGINEER OF RECORD SHALL BE NOTIFIED PRIOR TO PLACEMENT OF ANY REINFORCING OR FORMWORK IN THE AFFECTED AREAS. III. TIMBER CONNECTIONS D. ALL FOOTINGS SHALL BE LEVEL OR STEPPED UNLESS SPECIFIED OTHERWISE, A. ALL HARDWARE AS CALLED FOR ON THE PLANS (I.E., COLUMN CAPS AND BASES, BEAM AND JOIST HANGERS, STRAPS, FRAMING CLIPS, HOLDOWNS, ETC.) SHALL BE E. SILL PLATES IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE ICBG APPROVED. HARDWARE SPECIFIED HEREIN AS MANUFACTURED BY SIMPSON TREATED DOUGLAS FIR #2 OR BETTER, OR #2 FOUNDATIONS GRADE REDWOOD, AND STRONG -TIE CO.; EQUIVALENT HARDWARE MAY ALSO BE USED PROVIDING THE ICBO SHALL BE ATTACHED TO ALL STEMWALLS WITH ANCHOR BOLTS AS SPECIFIED IN APPROVAL REPORT ALLOWS LOADING CHARACTERISTICS EQUAL TO OR IN EXCESS OF THESE CALCULATIONS. THOSE OF THE SIMILAR SIMPSON TYPE. ALL HARDWARE SHALL BE INSTALLED WITH NAILS OR BOLTS EXACTLY AS CALLED FOR BY THE MANUFACTURER, OR AS NOTED ON F. ALL PIER FOOTINGS, BOTH ISOLATED AND INTEGRAL WITH CONTINUOUS FOOTINGS, THE PLANS/CALCS. SHALL HAVE REINFORCING BARS PLACED PER THESE CALCULATIONS. EACH BAR SHALL HAVE AT LEAST 3" CLEAR DISTANCE FROM REINFORCING BAR TO THE FACE B. NAILS CALLED OUT ON PLANS ARE TO BE COMMON, EXCEPT 16d's WHICH OF THE SOIL. SHALL BE SINKERS UNO. REMAINDER OF NAILING SHALL BE PER CBC NAILING SCHEDULES w/ TYPE NAIL AS SPECIFIED (COMMON, SINKER OR BOX). G. ALL CONTINUOUS FOOTINGS SHALL HAVE A MINIMUM OF TWO #4 BARS CONTINUOUS C. POSTS USED FOR BEAM OR GIRDER SUPPORTS SHALL BE EITHER (1) SOLID, ALONG THEIR LENGTH. ALL CONCRETE STEM WALLS OVER 2'-8" IN HEIGHT SHALL CONTINUOUS MEMBERS TO THE FOUNDATIONS, OR (2) SPLICED AT CEILING OR HAVE VERTICAL REINFORCING, #4 BARS MINIMUM, SPACED AT 48" O.C. ALL FLOOR LEVELS ONLY, WITH FULL DIRECT SPLICE CONNECTIONS SPECIFICALLY AS MASONRY STEM WALLS SHALL HAVE VERTICAL REINFORCING, #4 BARS MINIMUM, INDICATED ON FRAMING PLANS AND DETAILS. SPACED AT 32" O.C. UNLESS SPECIFIED OTHERWISE. D. FASTENERS SUCH AS NAILS, WOOD SCREWS AND LAG SCREWS USED IN PRESERVATIVE H. THE CONTRACTOR/BUILDER SHALL BE RESPONSIBLE FOR DETERMINING EXACT TREATED AND FIRE -RETARDANT -TREATED LUMBER SHALL BE OF HOT DIPPED ZINC -COATED LOCATIONS FOR ALL ANCHOR BOLTS, HOLDOWN ANCHORS AND STRAPS PRIOR TO GALVANIZED, STAINLESS STEEL, SILICONE BRONZE OR COPPER, PLACEMENT OF CONCRETE AND/OR INSTALLATION OF STRUCTURAL FRAMING, MEMBERS. IV. PLYWOOD DIAPHRAGMS 1. ALL FILL MATERIAL PLACED UNDER SLAB ON GRADES SHALL BE FREE FROM ROOTS, GRASS, OTHER VEGETABLE MATTER, CLAY LUMPS, ROCKS LARGER THAN 4 INCHES, OR A. HORIZONTAL DIAPHRAGMS: (1) ROOF SHEATHING - OSB PER PLAN WITH FACE GRAIN OTHER DELETERIOUS MATERIALS. GRASS, GRASS ROOTS AND INCIDENTAL TOPSOIL SHALL PERPENDICULAR TO THE SUPPORTS, IN A STAGGERED PATTERN Q.E., CASE I AND CASE III, CBC NOT BE LEFT BENEATH FILL AREAS. PLACE FILL MATERIALS IN LAYERS NOT EXCEEDING TABLE 2306.3.1). NAIL WITH COMMON NAILS PER CALCULATIONS. 6" LOOSE DEPTH. BEFORE COMPACTION MOISTEN, OR AERATE EACH LAYER TO PROVIDE OPTIMUM MOISTURE CONTENT. B. VERTICAL DIAPHRAGMS (SHEAR WALLS): ALL EXTERIOR WALLS OF THE STRUCTURE SHALL BE COVERED WITH MINIMUM OF 3/8" THICK CDX OR OTHER STRUCTURAL II PLYWOOD, OR EQUIVALENT SIDING (I.E.< T-1.11). MINIMUM NAILING SHALL BE DESIGN LOADS AS SPECIFIED IN THE SHEAR WALL CHARTS IN THESE CALCULATIONS. EDGE J NAILING SPECIFICATIONS SHALL APPLY TO HOLDOWN ATTACHMENT STUDS LOCATED 1. THIS STRUCTURE HAS BEEN DESIGNED WITH THE FOLLOWING PARAMETERS: WITHIN RESPECTIVE SHEAR WALL. SNOW � Pg (GROUND SNOW LOAD) = 20 psf V. PREFABRICATED TRUSSES I = 1.0 A. THE MANUFACTURER SHALL SUPPLY SHOP DRAWINGS AND BE COMPLETELY WIND RESPONSIBLE FOR THE DESIGN AND CERTIFICATION OF TRUSSES. THE WIND SPEED = 110 mph, 1=1.0 MANUFACTURER SHALL CONFORM TO TRUSS DESIGN ACCORDING TO THE LOADING EXPOSURE "C" CONDITIONS AS SPECIFIED IN THE CBC AND PER GOVERNING LOCAL BUILDING OFFICIALS. WIND LOADS ARE 34.3,-9,22.8,-5,-29.8,-20.6,-20.6,.15.7,-,41.6 L1 0 & -32.6 psf FOR ZONES A, B, C, D, E, F, B. THE MANUFACTURER SHALL BE ADVISED THAT LOADING DIAGRAMS INCLUDED IN G, H, EOH & GOH RESPECTIVELY. THESE CALCULATIONS ARE FOR REACTION DETERMINATION ONLY, AND SHALL NOT BE Q C� ASSUMED TO BE DESIGN SPECIFICATIONS OR RECOMMENDATIONS. SEISMIC SDS = .536, SDI = .338, SITE CLASS "D" C. EACH TRUSS SHALL BE BLOCKED AT EACH SUPPORT POINT, AT THE RIDGE POINT, R = 6.5, I = 1.0 AND AT ALL POINTS AS REQUIRED BY MANUFACTURER, AND SHALL BE ATTACHED TO THE PLATE WITH A SIMPSON H-10 CONNECTOR AT EACH SUPPORT (3 REQUIRED PER LIVE LOAD TRUSS) NOT REQUIRED ON THE TWO GABLE TRUSSES. ROOF = 20 psf FLOOR = 40 psf D. THE TRUSS MANUFACTURER SHALL BE RESPOSIBLE FOR ALL PERMANET AND TEMPORARY BRACING OF TRUSSES INCLUDING THEIR COMPONETS (IE. WEBS ETC.). CODE ANALYSIS: z OCCUPANCY CLASSIFICATION: R -3/U CONSTRUCTION TYPE: V -B ~Qw STORIES: 1 GARAGE ADDITION AREA: U - 2,455 SQ FT RESIDENTIAL ADDITION AREA: R-3 - 125 SQ FT — — — — TOTAL RESIDENTIAL AREA: R-3 - 2,366 SQ FT i to I� •o 1- Flood Zone; F.1.RM :Odea 7C 051S o IP 0 v N I bw — _ CL PRIVATE DRIVEWAY _ _ _ _ I ----------- ------------------i (-275.00') X1 GENERAL PRACTICE NOTES. A. BATHROOM AND RANGEHOOD FANS SHALL VENTILATE TO THE EXTERIOR OF THE STRUCTURE, AND HAVE A BACK DRAFT DAMPER. B. ALL PLUMBING FIXTURES (TOILETS, SHOWER HEADS.... ETC) SHALL BE WATER SAVING FIXTURES OR HAVE FLOW RESTRICTORS, AND BE IN COMPLIANCE WITH CGBS SECTION 4.303 AND MAXIMUM FLOW RATES OF: WATER CLOSETS 1.6 GPM, SHOWER HEADS 2.5 GPM, LAUNDRY FAUCETS 2.2 GPM AND SINK FAUCETS 2.5 GPM AS SET BY THE COLIFORNIA ENERGY COMMISSION. C. ALL INTERIOR AND EXTERIOR HOSE BIBS SHALL BE EQUIPED WITH ANTI -SIPHON DEVICE (EXCEPT AT CLOTHES WASHER. D. ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS, OR OTHER OPENINGS IN PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASSONRY OR SIMILAR METHOD PER CGBS SECTIOM 4.410. E. PER CGBS 4.410, AN OPERATION AND MAINTENANCE MANUAL ACCEPTABLE TO THE ENFORCNING AGENCY SHALL BE PROVIDED TO THE BUILDING OCCUPANT OR OWNER AT THE TIME OF FINAL INSPCETION. F. ALL DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE COVERED DURING CONSTRUCTION. G. EXTERIOR WALLS OF STRUCTURE SHALL BE WRAPPED WITH TYVEK WRAP AFTER SHEATHING AND PRIOR TO INSTALLATION OF SIDING. H. DRYER VENT SHALL TERMINATE TO THE EXTERIOR OF THE STRUCTURE AT ROOF WITH A BACK DRAFT DAMPER VENT CAP. J. LIFER GROUND: 1. UFER GROUND ELECTRODE SHALL BE PROPERLY SUPPORTED TO INSURE PROPER PLACEMENT WHILE CONCRETE IS BEING POURED. 4 SUPPORTS MINIMUM, EQUALLY SPACED WITH REBAR NOT TO EXTEND AT EITHER END FARTHER THAN 12". 2. REBAR STAKES MAY BE USED FOR SUPPORT OF UFER ONLY WHEN STEEL IS SLEEVED / ENCLOSED WITH A PIECE OF PVC CONDUIT. 3. UFER GROUND REBAR SHALL BE #4 MINIMUM x 17-0% AND CLEAN AND FREE O 7 F FOREIGN MATERIAL TO ENABLE MAXIMUM CONDUCTIVITY, AND LOCATED AT THE CENTER OF FOOTING AND 3" FROM THE BOTTOM OF THE FOOTING. f:. WATER HEATER SHALL BE SPACED ]"MAX FROM TWO ADJACENT WALLS AND SECURE WITH TWO STRAPS, ONE WITHIN THE UPPER AND LOWER THIRD OF UNIT, AND MINIMUM OFF 4" AWAY FROM CONTROLS. L. ALL VENTS PIPES USED SHALL BE DOUBLE WALLED. SINGLE WALLED VENT PIPES ARE NOT PERMISSABLE. M. THE GRADE ADJACENT TO THE FOUNDATIONS SHALL BE SLOPED AWAY FROM THE BUILDING A MINIMUM OF 6" WITHIN THE FIRST 10'-0" OR COMPLY WITH THE EXCEPTION IN 2013 CBC SECTION R401.3. N. LANDINGS AT EXTERIOR DOORS SHALL COMPLY WITH CBC 2013 SECTION R311.3. SHEET INDEX SHEET NO. I DESCRIPTION A.0 GENERAL NOTES, LOCATION MAP, SITE PLAN & SHEET INDEX A.1 EXISTING FLOOR PLAN A.2 PROPOSED FLOOR PLAN A.3 FOUNDATION & FLOOR FRAMING PLANS AA ROOF FRAMING PLAN A.5 DETAILS A.6 DETAILS A.8 EXTERIOR ELEVATIONS & DETAILS A.9 ELECTRICAL PLAN BUTTE COUNTY JAN 14 2016 DEVELOPMENT SERVICES Pks - aqg q r�ch�l� F SCOPE OF WORK: `cPO JOB SITE: 9890 FIMPLE ROAD 1 - REMOVE EXISTING GARAGE APN # 039-2:30-011-000 2 - CONSTRUCT NEW 2,455 SQ FT GARAGE 3 - CONSTRUCT A 125 SQ FT ADDITION TO LIVABLE SPACE 0 O Z O PERMIT# f��=Q-qfN p BUTTE COUNTY DEVELOPMENT— E— S RVICES REVIEWED FOR DURHAM DAYTON HWY CODE COMPLIANCE — DATE VIL'/6 BY LOCATION MAP _— - ------- 77—i---r�_'T7�' 11 IIT...-_.- —_ 1 7-1 _ W i Z O W _ Nw i fu �_ fie 0 w J E T 4— CD Z Z �_ _0 F_ LON U �[ �O u 0 0 L U v� Q(LORSSlpy� 1. LOE�� G' chi S m EXP 7i vT�lRucroRP. �Q ATF OF CAl\E��� UJ J I � W0 0 w w Q r w w w O L1 0 u Q u- 0 G LuLu � Q C� o0 �, — rnU 0 c CL wX �w _o W z w0- ~Qw ��w Z J Z = O C/) �' 0s W Z Z U w0J Lu H CD J DATE: 11-17-2015 SHEET: AOO # 1 of 1 O - L_ — I IIII I I II I L1. -A I EXISTING FLOOR PLAN SCALE: 1/4" = V-0" PROVIDE SMOKE DETECTORSIALARMS AS REQUIRED BY 2013 CBC SECTION 807 AND 2013 CRC SECTION R314 PROVIDE CARBON MONOXIDE DETECTORSIALARMS AS REQUIRED BY 2013 CBC SECTION 420.4 AND 2013 CRC SECTION R315 - INDICATES CO AND SMOKE DETECTOR LOCATION. -- U) Z O W �L 00 Lu Q Lu J � Eo C6 Z Q = L U Y Lo Lu J F- NM v V p Ln U oQROMS C -11cT m Cr EXP. _4A. a J'T �TRUCT 'rF OF CAl\FOQ� W W U Z D� W � W Q Z W W of w O 0 �U Q Li O oU u.jG W Q my O rnU el - z Ln r` m I rn Q C6 J L0 o M U) w of O o O J w _ l/ -^L V Z m /� w � �/ / ^Q '^y` w w Lu W F -- DATE: 11-17-2015 SHEET: Awl L#: 2 of 1 Q X4 4 31'-6" 10'-0" I A14'-0" X5 \ \ 12'-1 I' \ PROVIDE OPENINGS IN WATER HEATER \ ENCLOSURE MECHANICAL DOOR FOR COMBUSTION AND MAKE-UP AIR THAT o 0 COMPLY w/ CMC 2013 &CPC 2013. U U 3030 XO - - - - DG w/LOW E2 A - mfr°� w O 3 6x6 HD)k L_ X0 0 ° --- � OQ L=q' L=7 L=& x' 1O 1O 20 C MECH O ° p IO 6x121 HDR xl R F CEILING JO o, 3060 r-----11---- I I - WATER II I I Gam ' ' HFATER DRYER 11 WASHER L=12' � L=11' QOttE $q VSS L ---- -C2_�-i-- O Sp O FL=q' x 7 s0 bi-b G\ O X6 A.7 v LAUNDRY U V ,KA yeOOc, ° 3- 2x UNDER �y O! GIRDERTRUSS \ 2-2x TRIMMERS Srl Llk Nk(UaV9 ! xx' / t✓� I I \ �i2ur✓r. ENGIN R IVO - i I x 1¢ z x pC � IUW& Z o BATHROOM L=4' TRlMNAER' O \ 2-2x i i O O W \ tD 0 /A.7 0 II II � L-7.5 O \ DEMO EXISTING GARAGE YB GARAGE LAUNDF ROOM O \60 �O I L.. _._._ -_.___ _- C -_ _ _�_ U = CL DR N \ - D co O +��JSS L=6 10080 ROLLER L=4' �O / ac 6x12 DF HDR D a fo Oa zO A.7 L_q' L=q' A.7 TYP 5 L=22" 0) 101-011 SHEARWALL NOTES L-=66 1. ALL EXTERIOR WALLS & THE INTERIOR GARAGE WALL ARE 2x6" UNO. l by 6k6CP A.5 2. SHEARWALL CONSTRUCTION SHALL COMPLY w/ CBC TABLE 2306.4.1. p POST - O h-�°� LANDINGS AT DOORS 3. SHEATHING SHALL BE APA RATED PLYWOOD OR OSB & SHALL BE NAILED DIRECTLY TO l�J 4 SHALL COMPLY WITH 2013 CBC SECTIONS FRAMING.y� iy0 L=22" 1008.1 S, 1009.1.8, 1009.8 8 1010.7 or for 4. PANELS SHALL BE INSTALLED EITHER VERTICALLY OR HORIZONTALLY. MINIMUM 0� pip O �O� ,OA 31 i Bgs.20>3 CRC SECTIONS 3113 & DIMENSION OF PANEL IN ANY DIRECTION SHALL BE 2'-0" UNO. - b 5. NAILS SHALL BE 8d COMMON (2 1/2"x.1 310) & SHALL PENETRATE FRAMING 1 1/2" �t MINIMUM. NAILS SHALL BE DRIVEN SO THAT THEIR HEAD IS FLUSH w/ THE SURFACE OF a THE SHEATHING. GALVANIZED NAILS SHALL BE HOT DIPPED OR TUMBLED. q ti 1013 CRC SECTION R308.4 6. STAGGER NAILS @ADJOINING PANEL EDGES. Io L=7.5 / A.7 HAZARDOUS LOCATIONS Glazing trO installed in dwellings at hazardous 7. NAILING SHALL BE INSPECTED BEFORE COVERING. O locations shall comply with the 8. TOP PLATE SIZE TO MATCH SIZE OF SILL PLATE @BOTTOM OF WALL L=22' requirements of this section 9. ANCHOR BOLTS SHALLL CONFORM TO ASTM A307 & SHALL HAVE 8" MINIMUM j EMBEDMENT INTO CONCRETE w/ A STANDARD 90 HEAD UNO ON THE EMBEDDED PORTION. PROVIDE MIN 2 ANCHOR BOLTS PER SILL PIECE. PLACE END ANCHOR BOLT 6" MIN & 9" MAX FROM END OF SILL PLATE. 181-011 10. WHERE AN OPENING IS LOCATED BETWEEN TWO OR MORE SHEARWALLS ON S¢�\ THE SAME LINE, THE LINTEL ABOVE THE OPENING SHALL BE SHEATHED & NAILED YD FOR THE MORE SEVERE ADJACENT SHARWALL MARK. n 11. ALL SHEARWALLS SHALL BE NAILED w/ CONT PLYWOOD SHEATHING. BUILD 1 `� INTERSECTING WALLS AFTER SHEARWALL IS NAILED. 12. ALL SHEARWALLS SHALL EXTEND TO THE BOTTOM OF ROOF (OR) FLOOR DIAPHRAGM ABOVE & HAVE POSITIVE SHARWALL CONNECTION TYPICAL EXCEPT AS SHOWN WITH DETAILS. 13. STUDS @ MAX 16"o°. PROPOSED FLOOR PLA N 14. SEE ADDITIONAL DETAILS ON SHEETS A.5 &A.6. SCALE: 1/4° = V-0" -INDICATES EXISTING WALL. LIVING SPACE 125 SO FT GARAGE 2,455 SO FT 15. DO NOT PLACE PLUMBING VENT PIPES IN SHEARWALLS, AS NOTED. - INDICATES NEW / INFILL WALL. TOTAL 2,580 SO FT ` - INDICATES REMOVAL OF EXISTING. A SHEARWALL SCHEDULE STRONG-WALL SHEARWALL NOTES PLE;ASANTON, CA 94588. TEL: (800) 999-5099, FAX: (925) 875-0826. "SIMPSON STRONG -TIE NAILING ANCHOR END 2• INSTALLATION OF PRODUCT SHALL BE DONE IN STRICT CONFORMANCE TO THESE MARK MATERIAL EDGES:FIELD BOLT MEMBER ANC BLT HOLD DOWN r) C� 3/8" PLY or OSB 8d @ 6":12" 2-2x PAB5 HDU2-SDS2.5 C� 3/8" PLY or OSB 8d @ 6":12" --- 2-2x PAB5 HDU4-SDS2.5 C3� 3/8" PLY or OSB Sd @ 6":12' --- 2-2x PA65 HDUS-SD52.5 C'4� 3/8" PLY or OSB 8d @ 4":12° --- 2-2x PABS HDU4-SDS2.5 SW22x8x6 --- --- PAB7 --- STRONG-WALL SHEARWALL NOTES PLE;ASANTON, CA 94588. TEL: (800) 999-5099, FAX: (925) 875-0826. "SIMPSON STRONG -TIE COMPANY INC." 15 AN ISO 9001 REGISTERED COMPANY. 2• INSTALLATION OF PRODUCT SHALL BE DONE IN STRICT CONFORMANCE TO THESE DRAWINGS AND THE STRONG -WALL INSTALLATION GUIDE. MODIFICATIONS TO THIS PRODUCT AND ASSOCIATED SYSTEMS OR CHANGES IN THE INSTALLATION METHODS SHOWN ON THESE DRAWINGS AND THE INSTALLATION GUIDE SHOULD ONLY BE MADE BY A QUALIFIED ARCHITECT, CIVIL, OR STRUCTURAL ENGINEER. THE PERFORMANCE OF SUCH MODIFIED PRODUCTS OR ALTERED INSTALLATION PROCEDURES IS THE SOLE RESPONSIBILITY OF THE DESIGNER. REFER TO ICC ES REPORT FOR FURTHER INFORMATION. 3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, ELEVATIONS, ETC. PRIOR TO INSTALLATION OF ANY COMPONENTS FOR THE STRONG -WALL SYSTEM. IF ANY DISCREPANCIES ARE FOUND, THEY SHALL BE BROUGHT TO THE ATTENTION OF THE PROJECT ARCHITECT, PROJECT ENGINEER OR BUILDING DESIGNER FOR CLARIFICATION PRIOR TO CONSTRUCTION. 4• THE CONTRACTOR SHALL VERIFY THE POSITION OF THE STRONG -WALL IN RELATION TO THE REST OF THE BUILDING SYSTEM AS SHOWN ON THE PROJECT DRAWINGS. Ft Le, GNr7 I U) r i v / 7 Z 0 W i C C Q N00 w J Z 0) o TI 0 1- r Zuj J W O U � 0 Li) ce U N QROFESSlpy� �� z P5328C9 M 40 n EXP ii d,TRSCT ATF OF CAl\EO�� W �J U 0 W 0 W o Q z W Oro W X 00 4 20 11Q LL 0 U W< LU oU rn= 0 U' rnU n- L0 LO O M LO li 0 2 Z Q = U) 0 m �0 W 00 a J LU LU J U. H ^ I L H DATE: 11-17.2015 SHEET: Am2 # 3 of 10 Q NOTE: SHEATHING TO BE 3/4' T&G STURDIFLOOR W/ 1 Od @ 6"oc EDGES & 12"oc FIELD. FLOOR FRAM I NG PLAN SCALE: 1/4"= 1'-0" FOU N PATI ON PLAN SCALE: 1/4" = V-0" 91 - -�F I YTI - -T- %a %-/ VE�Q°NEN- SE VICES VED FOR MPLIANCF p �O Lo U V F U N QROFESS/pN J. LOFT �F! m EXP6.3�^� rn �T'TFOF CAUF���P W w U Z 0� W � W a Z W ry W w O D aU Q of IL O u LU O LU r Qo U_ cm2 cm a z Ln ti (10 Q U rn ZJ C:) J w Z O Z G ~ O 9U QLL m Z 0 w Wof' O a Ow LU F_ LL LL rDATE: 11-17-2015 SHEET: Am3 # 4pf 10 4 3 2 1 (DB ROOF FRAMING PLAN SCALE: 1/4" = 1'-0" au (50%) / 51 = 1 VENTSURE METAL ROOF VENT MIN. 60 (50%) / 34 = 1 EAVE VENT MIN. ROOF FRAMING NOTES: 1. ALL SHEATHING TO BE 7/16" OSB w/ 8d @ 6"oc EDGES & 12"oc FIELD. 2. TYPICAL ROOF FRAMING IS TRUSSES UNO, ENGINEERED BY THE MANUFACTURER. BOTTOM CHORD OF TRUSSES TO BE BR/ ':-i AS SPECIFIED BY TRUSS SUPPLIER. 3 INDICATES OWENS CORNING VENTSURE METAL ROOF VENT or EQUAL (51 SQ INCHES FREE FLOW AREA). (12) REQD OVER GARAGE AND (2) REQD OVER HOUSE ADDITION. U) z 0 U) W _ C •L a� c d' m� rn w o Ern 0 orn Z 0 2� W a) ca L' O cu F U u — 0 �� U N QROFESS/pyo J. LOFT �c V 8 Z m co C= EXP.%" z ATF Of CAUF��� U W z 0 W 0 W Q Z Woof W w O 2U Q u -O u W Q Lu oU rn= 0 (D rnU L0 (fl z U' rn Q J o M �nIx v z O 7 Q U w w U. m L= w 0 Q 00- W Lu � J a H °ATE` 11-17-2015 SHEET: Am4 # 5 of 10 _ ZH��u11►� ]►^�1►� ES OF i IN TOP PLATE S -1 6d ES OF SPUCE BOTTOM NOTE: AS AN ALTERNATE TO THE NAILING SHOWN ABOVE, USE LSTAl2 STRAPS EACH SIDE OF 2x TOP PLATE SPLICE TYPICAL TOP PLATE LAP DETAIL V - r -a ST22 STRAP EA SIDE OF TOP & SILL PLATE - A35 TYP ES T&B 2' ADDED 2x STUDS AS REQD SECTION PIPE PER MECH 4" OD MAX @ 6x WALLS TOP OF CONCRI NOTE: REFER TO THE CURRENT SIMPSON C -SW CATALOG FOR TEMPLATE SELECTION CHART. VT EXTERIOR TEMPLATE :OR 2x FORM BOARDS) STRONG -WALL TEMPLATES NTS SIMPSON 4' 10" DIA MAX HOLE MIN THRU WALL I I I I PLYWOOD EDGE y 1 I I I I 1 ----SII BLKG REQD I.I @ HOLES > 4' DIAMETER l S" I _ u_ _-LJ_ D D D °.. D D . . D p •I I PAB ANCHOR BOLT ° ° D- N PER HOLDOWN SCHED D D� PLYWOOD SHEAR WALL EDGE NAIL TO ALLPER PLAN BLOCKING SECTION C7 MUDSIL PER SHEAR WALL SCHI S) NAIL 2-2x w/16d @4' oc STAGGERED HOLDOWN MEMBER PER SCHED —HDU HOLDOWN SECTION r=r.a SINGLE & DOUBLE PORTAL ASSEMBLY NTS SIMPSON @ HEADER, FIELD NAIL THRU SHEATHING & METAL STRIP w/ 1 Od COMMON NAILS or 16d SINKERS @ LOCATIONS MARKED BY PAINTED DOTS —� TOP OF PANEL TOP OF WALL CONNECTION NTS SIMPSON NUT AND PLATE WASHER NOTE: LOAD PATH DESIGN & DETAILS ABOVE HEADER TO BE PROVIDED BY OTHERS PRE-INSTALLED HDQ8 HOLDOWN ALLTHREAD ROD _ STRONG -WALL POST STUD SHOE NOT COUPLER NUT SHOWN FOR CLARITY BEARING PLATE WITNESS HOLES w/ SDS 1/4 x 2 1/2" VISIBLE FOR SCREWS PROVIDED INSPECTION AfftWITH WALL II II 5/8' DIAMETER 1 1 ANCHOR BOLT a a e e d Q a Q ° a Q d ° d a d ° a PORTAL WALL SILL NTS SIMPSON I I SHWHIN PER 4/A.5 DETAIL NTS FULL LENGTH GARAGE HEADER 5 3/4" A STRAP 3/A.5 PLATES OF STRONG -WALL 1/4'x6' SCREWS BUTTE COUNTY pEVELOPt`.AEi 1T SERVICES REVIEWED FOR COLE COMPLIANCE DATE _ BY TOP OF WALL CONNECTION NTS SIMPSON 117, co Z O r� v / MW 1..1. m �L cu r Lu � Z 9:2 0 di OQJ L0 V Z w75 5 L O v CC 0 G LO H CCU I Cie G U In QROFESS S5 m P- 0-( sT P� X �T�IF OF CAl\F�Q�P W W U Z 0� W :E W o Q Z W W Of dV O u Q u- O u W Q oU Lu O rn0 o[ d to LO 1 r.. 0 M w IlyO >2 U V J m cl w (Q 1 d W w Lu Of❑ J � LL/1 H DATE: 11-17-2015 SHEET: AM AVA m.5 # 6 Of p 117, (N) RAFTER (I rye SECTION 1' = 1'11' ENGL702 2x BLOCK PER PLAN w/ 1- A35 @ EA BLOCK DBL TOP SILL 2x FACIA TO MATCH (E) O'HANG PER PLAN ROOF SHEATHING PER PLAN EN TRUSS TO WALL CONNECTION 1'=,'-0. ENG H2A @ EA TRUSS AFTER TAIIS CH (E) 3SES TRUSS BY OTHERS SECTION 1'-1'-O ENGLIM (N) ROOF SHEATHIN TYP (N) ROOF SHEATHING 2- 2x6 DF SHAPED PER PLAN —� (N) RAFTER EN SECTION STUD WALL 0.1450 PDF @ 24"oc 2x PT SILL MAX CONC PENETRATION = 1/3 SLAB THICKNESS SOG p D SILL PLATE TO CONCRETE SLAB CONNECTION 1"- V.0' -_- ENG FG or PAVING SECTION 1• = 1'-O ENGt8 SECTION SEE A/S.6 & 2/A.7 FOR ADDL INFO HDU PER SCHEDULE EN PAB PER SCHEDULE 1-#4 CONT • o WD FG ° SOG 3" CLR TYP 244 CONT 2'-0" MIN SEE 2/A.7 FOR ADDL INFO SECTION 1'=,-0' ENGLI Ocr-mLlw4►1cl SECTION 1'=1'1T ENGL8 "ili Jill 8 -�> I 7— Z -!--T -a T BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE 4 SHEAR WALL PER SCHEDULE @ "3A" SIMPSON STRONG WALL @ "3" PER PLAN EN U� PAB 1-#4 CONT PER SCHEDULE o 8" FG SOG Z V D 344 CONT T&B 3- CUR TYP C7 3 SEE 2/A.7 V FOR ADDL INFO 1'-6" 1'-6" 12 SECTION 3 v/'"� V - P-0' ENGE2 U) i Z O J�^J v w 0) C �L a) c� rn 0 W o Lu J E o TT z Z_�^E++ VJ p a: LIDn Lu W J u YO muc„) U - p stn U N QROFESS/pyo J. LOFT i� m EXP al L a it sr P•, tt JJ RUCTUS \Q ATF OF CAUEO�� W �J U ■Q. W O W ❑ Q Z W w O D.. U � LL' u W Q Lu oU rn= O � rnU LO CID LO 6CT r LO 0 M L w o F— W U_ J m 1 Q w d w Lu Q J ^ L.L H DATE: 11-17-2015 SHEET: j: r Am6 # 7 of 1 4 2x Tll ll 111 ATL SECTION 1' = 1'-0' ENGL1000 STEP DETAIL 1' - 1'-0' ENGL50 S/A.7 PER 6/A.7 111ofela 1 SECTION 1' = 1'-0' ENGLI003 SEE 3/A.7 FOR ADDL INFO SECTION 1' = 1'-0' ENGL1007 FG DO NOT USE VERTICAL CRIPPLE STUDS TO TRUSS ABOVE FILL THE GAP BETWEEN THE HEADER & THE DOUBLE TOP PLATE USE HORIZONTAL BLOCKS PLACED UNDER EACH TRUSS, AS SHOWN SIMPSON STRONG WALL PER PLAN EN EN 144 CONT 1 z ZD C 51 244 CONT l'-0" MIN EXTEND ALL (N) REBAR INTO (E) FOOTING w/ 6' EMBED, EPDXY IS NOT REQD 2x BLQCK PER PLAN w/ 1- A35 @ EA BLOCK ROOF SHEATHING PER PLAN EN TRUSS BY OTHERS IR19 1/2'GWBDBL TOP SIR38 INSULATION OVER (N) KITCHEN AREA 2x FACIAH2A @ EA TRUSS TO MATCH (E) O'HANG1/2" GWB PER PLANUSE 5/8" GWB @ 1 HOUR FIRE WALL (SEE PLAN) INSULATION WHERE OCCURS EXTERIOR SHEATHING PER PLAN & SCHEDULE wl'm mim —2x6 DF STUD @ 16"oc 2x PT SILL FG SOG PER PLAN d \ D D FOUNDATION PER PLAN TYPICAL FRAMING SECTION r - I. -a L.111 M 2x6 PT SILL w/ 1/2"0 x 10" ANCHOR BOLT & WASHER PL 0.229 x 3" SQ @ 6'-0"oc & 12" FROM ENDS & SPLICES UNO PER PLAN EN D 144 CONT o d 8' FG SOG \�7575/7775//\i D D7575/ `\i\\\\/ 3" CLR TYP f / 244 CONT 2'-0" MIN . °— SEIFFURRIN.Gll H SECTION /.�EMENTp1ACTER* L "=1-0 ENGL7001 VGl1/�G(�\1 1 VY�G�� DBL 2x TOP PLATE —� SILO. RUNNER OR.RATE WEEP SDREED! •i . 4 a �. LLT ir V 6• •A r4 `. fWNDAMON ge CL a �pC ALTERNATE PERFORATED.WEEP CASING 9EJV5 rD r -o E. IUEE1 S REED 9.CC NC FC ICDA I( l EN 1/2" 2x4 STUD @ 16"oc MAX SOLID BLOCK 2x PER PLAN w/ 2- 16d @ EA STUD & 2- 16d EA BLOCK JOIST HANGER SEE 4/A.6 EN SOG D V ° o p � SECTION 1'=1'-0' ENGLID05 M FLOOR SHEATHING PER PLAN -JOIST PER PLAN Tj.,L, -IT� '11'.I1 IT -7 � SHEATHING 2x6 STUD @ 16"oc PER SCHEDULE & R19 INSULATION 3 FLOOR SHEATHING PER PLAN 5/8" GWB��] w r/—,JOIST PER PLAN EN � JOIST HANGER 2x PER PLAN EN w/ 2- 16d @ EA STUD d & 2- 16d EA BLOCK SOG d d D D •\\\i�\ ,�\�\\ 7575</\\ d 7575/ d D- o i O D d d SECTION ENGLIOCa ►$#yk11► AL'lP►KlLI_\I e1NL F z b SEE 2/A.7 FOR ADDL INFO EXTEND ALL (N) REBAR INTO (E) FOOTING w/ 6" EMBED, EPDXY IS NOT REQD V Z O r� v - 1 NW �L Rf00 W J E Z /o/����, LY O VJ o = r- z W J m � V G Liz G U cn �pQ�OFESS/pN J. LOFT �F kQy P0�' W 8 �, z EXP.6-3vit l �TRUCT O- \Q- �TFOF CAL\EO�� j W Uw Z p � w W Q Z W w LU w 0�U o Q LL uw oU_ = �< 0 0. V 00 a) U CL Lo (D LI') 1 U) 7775 M W 111vill x BUTTE COUNTY DEVELOPn,iENT SERVICES REVIEWED FOR CODE tUiPLf'�;E� By d�_z J m A_ 0 CL W J Q DATE: 11-17-2015 SHEET: Am7 # 8 of 1 Q .T-1 r1l_......IT _) REDWO, T NORTH ELEVATION WEST ELEVATION EAST ELEVATION Pipe sizing shall be as elsewhere required in this code. • The island sink drain, upstream of the returned vent, shall serve no other fixtures. • An accessible cleanout shall be installed in the vertical portion of the foot vent. I I r rr;ea�W .gym as . Y 1 r •,a _•• �I11 jlpw . w—w- w J d HORtZIDNWAL DRAW r PERMIT# &r_ 29 GL( BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODECOMPLIANCE • ISLAND SINK VENTING 2013 CALIFORNIA PLUMBING CODE SECTION 909.0 ILe following is a list of the general requirements for special venting for island fixtures based on the 2013 California Plumbing Code. Itis handout is intended to provide only general infonnation, contact thk Building and Safety Division for any questions or additional Information. 2_013 CPC Section 909.0 Oland Sink Ventine • Traps for island siriks and similar equipment shall be roughed in above the floor and shall be permitted to be vented by extending the vent as high as possible, but not less than the drain board height; and then returning it downward and connecting it to the horizontal sink drain immediately downstream from the vertical sink fixture drain. • The return vent shall be connected to the horizontal drain through a wye-branch fitting and shall, in addition, be provided with a foot vent taken off the vertical fixture vent by means of a wye br4nch immediately below the floor and extending to the nearest partition and then through the roof to the open air, or shall be permitted to be connected to other vents at a point not less than f inc'nes above the floor -level rim of the fixtures served. • Drainage fittings shall be used on the vent below the floor level, and a slope of not less than N inch per foot back to the drain shall be maintained. • The return bend used under the drain board shall be a one piece .fitting or an assembly of a 45 degree, a 90 degree, and a 45 degree elbow in the order named. _ -- - - 11I III 1 '11 1 T T I I F- -- 0 U) Z O U) W C �L �00 tQ LUo w J r— �� Z z _� 0 =6 LO J N U I—fif M U O �� U V) QROFESS/O,y� uclo1 ox V Z EXP 5� S� TRUCTUPP �R �TFOF CAUFO�� r f U W Z � W ! �LU W0° o z W W O dU Q LL 0 U LU Q oU rn U a U)�' Z CO OL0 M LO > W W 0 J W NW 0L U) V O j LL Q W W p Q Q X D_ W J LU W 06 DATE: 11-17-2015 SHEET: AF U /M0%8 ■ # g of 1011 0 X4 4 3 2 Furnace and water heater \ combustion air venting Vent shall terminate per manufactures' listed instructions and the requirements of 2013 editions of the CMC and CPC \ Furnace and water heater Clearance and Makeup Air Requirements shall comply with manufactures' listed instructions and the requirements of 2013 editions of the CMC and .CPC \ 1 DISPOSAL & ' DISH WASHER , GFCI BELOW COUNTER WP MS / s \ \ SSSS\- ,' GFO GFCI 4 4 3 3 1 �hR GFCI 220°GFG I DRIER p WISHER I —3 Cf) //,' \\`—, ,,CSS ((� // — \i i/ /'//✓�,F I LAUNDRY / I I BATHROOM IL — I \ \ -- - - -- — — — — — — 1, \ _ _ _ _ _ _ _ _ — __--_4O A GARAGE Mc 1 ` \ MS Tn I NOTES: 1 / 1. ALL RECEPTACLES TO BE ARC FAULT PROTECTED. i 2. ALL LIGHTS TO BE LED. / - -- - 3. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALL IN DWELLING SHAI-L BE ARC -FAULT CIRCUIT -INTERRUPTER PROTECTED AND LISTED TAMPER-RESISTANT RECEPTACLES. - - - ' COMPLY WITH CALIFORNIA / ELECTRICAL CODE -ARTICLE »O 4. PROVIDE TWO OR MORE 2- AMP SMALL APPLIANCE BRANCH CIRCUITS EVENLY PROPORTIONED IN THE KITCHEN, PANTRY, BREAKFAST ROOM, REQUIREMENTS FOR ELECTRICAL / DINING ROOM OR SIMILAR AREA TO SERVE ALL WALL AND FLOOR RECEPTACLE OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS PER EQUIPMENT INSTALLATIONS 2013 CEC ART. 210..52(B). 5. LAUNDRY ROOM RECEPTACLE OUTLETS SHALL BE SUPPLIED BY AT LEAST ONE 20 AMP BRANCH CIRCUIT. SUCH CIRCUITS SHALL HAVE NO OTHER COMPLY WITH CALIFORNIA OUTLETS PER 2013 CEC ART. 210.11(C)(2). / ELECTRICAL CODE -ARTICLE 250 6. FIXTURES, LAMP HOLDERS AND RECEPTACLE OUTLETS SHALL BE SECURELY SUPPORTED. A FIXTURE THAT WEIGHTS fvIORE THAN 6 POUNDS OR REQUIREMENTS FOR GROUNDING EXCEEDS 16 INCHES IN ANY DIMENSION SHALL NOT BE SUPPORTED BY THE SCREW SHELL OF THE LAMP HOLDER PER?013 CEC ART 410.30(a). AND BONDING OUTLET BOXES SHALL NOT BE USED AS THE SOLE SUPPORT FOR CEILING (PADDLE) FANS PER 2013 CEC ART. 314.27(A)& (D). 7. ELECTRICAL PANEL AND SUB -PANEL GROUNDING SHALL COMPLY WITH 2013 CEC ART. 250-32. PROVIDE SEPARATE GROUNDING WIRE TO - - EACH PANEL FROM THE MAIN ELECTRICAL SERVICE ENTRANCE PANEL. _ - - - - - - COMPLY WT H CALIFORN61 ELECTRICAL — — CODE—for wmag methods— secure conductors and conduit per ell applicable '.,..r.. requirements as required by the 2013 CEC for BSc' the specific method of wiring Provide readily accessible capability to circuit breaker(s), disconnect(s), fuse(s),switch(es) and their accessories as required and defined in Califomis Electrical Code 3 Label, circuit breaker(s), disconnect(s), fuse(s),switch(es) and their accessories, to identify their location and or equipment ELECTRICAL PLAN SCALE: 1/4" = V-0" LAUNDRY ROOM PROVIDE SEPARATE GROUNDING CONDUCTOR FROM MAIN ELECTRIQAL SERVICE PANEL TO REMOTE STRUCTURES AND REMOTE - SUBPANELS. CEC AFIT. 250.32 (D) CMC 504 ENVIRONMENTAL AIR DUCTS SHALL BE INSTALLED AS OFSCRTRFD RY THIS CODF KITCHEN PROVIDE SMDKE DETECTORSIALARMS As REQUIRED ey 2013 CBC SECTION 807 AND 2013 CRC SECTION 8314 PROVIDE CARBON MONOXIDE DETECTORSIALARMS AS REQUIRED BY 2013 CBC SECTION 420.4 AND 2013 CRC SECTION R315 ENTRY PORCH PERMIT# Z 7 e BUTTE COUNTY DEVELOP—MENTSSERVICESS REVIEWED c L FOR ( _ BY p U SINGLE RECEPT ck�: G 01 0 MOTION SENSOR P DUPLEX RECEPT 4'-0" FLOURESCENT LIGHT S SWITCH GFCI S THREE-WAYSWITCH 6 DUPLEX GFCI RECEPT 3 W FL FLOURESCENT LIGHT S FOUR-WAY SWITCH GFCI WP Z 0� 4 6 DUPLEX GFCI WATERPROOF RECEPT LIGHT Sp DIMMER SWITCH 220 RECEPT RECESSED LIGHT C0 W ctf 220 -. Z LU 0 CABLE TV Ov a� 0 EXHAUST FAN /LIGHT d U Q WP EXHAUST FAN w/LIGHT Q TELEPHONE JACK CEILING FAN & LIGHT OPTION WET AREA APROVED ® A/C SMOKE ALARM w/BATTERY BACKUP rnU (AS INDICATED ON PLAN) MOTION SENSOR PHOTO I' MS T O THERMOSTAT CONTROL LIGHT — — CODE—for wmag methods— secure conductors and conduit per ell applicable '.,..r.. requirements as required by the 2013 CEC for BSc' the specific method of wiring Provide readily accessible capability to circuit breaker(s), disconnect(s), fuse(s),switch(es) and their accessories as required and defined in Califomis Electrical Code 3 Label, circuit breaker(s), disconnect(s), fuse(s),switch(es) and their accessories, to identify their location and or equipment ELECTRICAL PLAN SCALE: 1/4" = V-0" LAUNDRY ROOM PROVIDE SEPARATE GROUNDING CONDUCTOR FROM MAIN ELECTRIQAL SERVICE PANEL TO REMOTE STRUCTURES AND REMOTE - SUBPANELS. CEC AFIT. 250.32 (D) CMC 504 ENVIRONMENTAL AIR DUCTS SHALL BE INSTALLED AS OFSCRTRFD RY THIS CODF KITCHEN PROVIDE SMDKE DETECTORSIALARMS As REQUIRED ey 2013 CBC SECTION 807 AND 2013 CRC SECTION 8314 PROVIDE CARBON MONOXIDE DETECTORSIALARMS AS REQUIRED BY 2013 CBC SECTION 420.4 AND 2013 CRC SECTION R315 ENTRY PORCH PERMIT# Z 7 e BUTTE COUNTY DEVELOP—MENTSSERVICESS REVIEWED c L FOR ( _ BY p U cup ck�: G 01 Q�OMS/O,y� 00 7 8 m EXFCOAA)� I`r �J'l,'�,TROCTORP ��P 1 FOF CAUFO� I W W U Z 0� W� C0 W ctf a -. Z LU W W Ov a� 0 d U Q LL 0 U LU Uj 0 0r.00 CD rnU I' L0 LO LACI') ZCD n M 11.0 J W � J ILL! U 0 � m U W. W W a J W U-1Ix W 13- F -- DATE: 11-17-2015 SHEET: Am9 ress'se #.:17-0 of loll 4