HomeMy WebLinkAboutB15-3049SHEET INDEX
VICINITY MAP
SYSTEM INFORMATION -
Q Q • ° - 0-
O
IE-01
TITLE SHEET
# , -� f n1 §. • �4 �
� Cordel"la Cl 'tin --- mt, "� `�'
AVmendlact `v ; t :
a�* '� t„ }_
..
�-'"
SYSTEM SIZE
8.1 kW DC
IE-02
SITE PLAN
PV MODULES
.30 SUNEDISON 270W
IE-03
PV MODULE ARRAY LAYOUT
s
1_ + i Aii(dffLn t
-0m ,1 Y �- �- �, a .K
�- � ( ,.'� .�
�Y
INVERTERS
30ENPHASE.M215 MICROINVERTERS`
e n•e rg y
Infinity
y Energy
IE-04
ELECTRICAL DIAGRAM
RACKING
UNIRAC
IE-05 SIGNAGE
MOUNTING,'Q
UICKMOUN T
�.Y� � •#: � 1 r _ � fir° � { , w �" � � .,(�
1420 E Roseville Pkwy
SCOPE OR WORK,.,- .
U. - I
{
1N,SacramentoAve W Sacramento:Ave N1
---L,`:,�-
oseville, CA 95661
:: I
'
INSTALLATION CONSISTS OF 30SUNEDISO`N 270W,;
_
✓
_; tv
MODULES, 30 ENPHASE MICROINVERTERS AND
T:916-474-4723
RELATED ELECTRICAL METERING (IF USED)AND
,
- CSLB: #998627
SAFETY EQUIPMENT.
`PROJECT
ALL COMPONENTS ARE UL.LISTED AND CE.0 CERTIFIED;
INFORMATION
-
W, t 33Kin9sbu!ryCt I , r}' �
�..
WHERE WARRANTED
NAME:
LORI 'BARKER
�A t
ALL' EQUIPMENT WILL BE INSTALLED AS REQUIRED,BY
ADDRESS:
32 KINGSBURRY CT
APPLICABLE CODES AND LOCAL UTILITY- COMPANY '
CITY:
CHICO
r. o�
s LazY7r`ail_Dr W,infde"Dt
REQUIREMENTS.
AHJ:
BUTTE COUNTY
EXISTING BUILDING INFORMATION.,
S4� M�Se' �-` .s
�. t
h ,�
PROJECT#.
F4162
APPLICABLE CODES.
STRUCTURE TYPE: RESIDENTIAL OCCUPIED BUILDING.
ROOF FRAMING: 2"X4" RAFTERS, 24" OC
2013 NATIONAL ELECTRICAL CODE (NEC)
2013 CALIFORNIA ELECTRICAL CODE (CEC):t�,F�7
� f ,. 4: ,*� ,fit +.o
;. Y +
ROOF TYPE: COMP SHINGLE -
2013 CALIFORNIA BUILDING CODE (CBC)
CONSTRUCTION NOTES `
2012 INTERNATIONAL BUILDING CODE (IBC)
A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS
THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY,GRID INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES
t
SYMBOLS
_.
- _
A GROUNDING ELECTRODE SYSTEM IN'ACCORDANCE WITH NEC 69047 AND 250-50 THROUGH 60 250-166 SHALL BE PROVIDED PER NEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAYBE
•AHJ SIGNATURE AND DATE
USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE
USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND N_O GREATER THAN
..:.0 METER
::
#8 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE,OR A COMPLETE GROUND.
. E
EACH MODULE WILL BE GROUNDED USING THE SUPPLIED GROUNDING POINTS IDENTIFIED BY THE MANUFACTURER. .
INVERTER
'EXPOSED NON -CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF
VOLTAGE..
'
V
- SHEET TITLE.
..
PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED PER SECTION 110.26 CEC �
1 GROUND
ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC, ENGRAVED IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTACHED USING AN APPROVED METHOD. IF EXPOSED TO '
SUNLIGHT, IT SHALL BE W RESISTANT.
TITLE SHEET
•�' SWITCH
ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY 2013 CEC AND 2011 NEC. '
SHEET NUMBER
•�� BREAKER
HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6' 7" PER NEC 240.24 '
THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER
rr 1
O
FUSE
WIRE PER NEC 250.64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER NEC 250.64C. ` :
` 1 .
— CONDUIT RUN
ALL EXTERIOR CONDUIT SHALL BE PAINTED TO MATCH ADJACENT SURFACES.
+•
THE PV CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION. NEC690.64(B)(7) .
7C WIRELESS
SITE CONDITIONS SHALL PREVAIL IF NO SCALE IS GIVEN. DRAWINGS ARE NOT NECESSARILY TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR UPON COMMENCEMENT OF
CONSTRUCTION.
... _ ...
..
a
a
f
4�. � .• .. �
.. ... .. `~,J''� � .- -
•. ."Y. ..
_. ,`,
,...'.
. a rte..
a 1 � .. '.