Loading...
HomeMy WebLinkAboutB16-0144pk 163' 1 Array Location w Main Service Panel 120/240V 200A NEMA 3R �u.,,�anel 120/240VAC 100A NEMA 3R Ii 389' ,1 S ti Site Plan Drawn By: Client : Jerry Lacey 21 Cooleys Way, Oroville 95965 Date: 1/13/2016 Ph. - Email - Scale - NTS 11.22KW DC Photovoltaic Sysbem (44 Canadian Solar CS6K 255P) Rev. Date Description k C 389' ,1 S ti Site Plan Drawn By: Client : Jerry Lacey 21 Cooleys Way, Oroville 95965 Date: 1/13/2016 Ph. - Email - Scale - NTS 11.22KW DC Photovoltaic Sysbem (44 Canadian Solar CS6K 255P) Rev. Date Description f 6„ ' 6" . ' 6" 0' 11 7/8" CH 0 q 0 cm 0 ( 0 0 (M 0 cm 0 (N 0 ® 6' Max . I , li li li 0 C, O 0 0 0� II ill II II 30' 29' 8 5/8" II n ® li Microinverter I Comp roof stanchion ❑ �❑ �❑ El 0 - 14' 10' 10' 4' To MSP 40' .. (3) THHN #2 Subpanel �r (1) #2 Gnd . _ ` Junction box 120/240VAC 100A NEMA 3R N To Subpanel NMB 10/3W/G 1. THIS SYSTEM IS GRID-INTERTIED VIA (44) UL -LISTED POWER CONDITIONING INVERTERS ENPHASE M215-60-2LL-S22 (240 VAC) W/INTEGRATED GROUND LU 2. THIS SYSTEM HAS NO UPS, NO BATTERIES 3. THIS IS A ROOF -MOUNTED SYSTEM, ADDING 2.81 LB/sgFT. ROOF IS (1) LAYER COMP ROOF SHINGLES (ROOF SLOPE IS 5:12) O4. ROOF JOISTS ARE 2X4" ENGINEERED TRUSSES AT 24" O.C. SPACING 15. LAG SCREWS ARE 5/16" x 4" AT 72" O.C. MAX, W/3" INTO FRAMING. Z6. LABELING DETAIL ON ATTACHED SHEET 7. BUILDING IS (1) STORIES. Roof Plan & Truss Section Drawn By: Client : Jerry Lacey 21 Cooleys Way, Oroville 95965 Date: 1/13/2016 Ph. - Email - Scale NTS 11.22kW DC Photovoltaic System (44 Canadian Solar CS6K 255P) Rev. Date Description (15 Per String) Enphase M215-60-2LL-S22 240(VAC) micro -inverters Pmax (Each): 22$ watts, Imax (Each) = 0.9 A, 240(VAC) n (14) Enphase M215-60-2LL-S22 240(VAC) micro -inverters Pmax (Each): 225 watts, Imax (Each) = 0.9 A, 240(VAC) 200A Utility Meter Main 240V electric service from utility (1) 200A main breaker = SubpanelFeed — (3) #2 THWN-2 (1) 1/C #8 Grid 3/4" conduit 125A Subpanel (44 Total) Canadian Solar CS6K-255P 255W -STC photovoltaic modules. R For Each Module: Voc = 37.4 VDC Vmp = 30.2 VDC Isc = 9.0 A Imp =8.43A Enphase & Unirac integrated grounding. Circuit 3 Icont = 15.75 A, 240 VAC (3) #10 THWN-2 (1) 1/C #10 Grid 3/4" Conduit Single Line Drawing Drawn By: David W Client : Jerry Lacey 21 Cooleys Way, Oroville 95965 - Date: 1/13/2016 Ph. - Email - Scale - NTS 11.22kW,DC Photovoltaic System (44 Canadian Solar CS6K 255P) 80A/2P ( i J Circuits 1-2 Icont =16.875 A, 240 VAC (3) #10 THWN-2 (1) 1/C #10 Grid 3/4" Conduit AC CALCULATIONS Circuits 1-2 Continuous Current = Imax x 1.25 = 13.5 A x 1.25 = 16.875 A Derate Ampacity = 90deg Rating of Conductor (T-310.16) x 90deg Temp Correction Factor (T-310.16) h x Conduit Fill Factor (T-310.15(B)(2)(a) =40Ax.87x1.00=34.8A So that, Derate Ampacity > Continuous Current = 34.8 A > 16.875 >> OK And, Derate Ampacity > Overcurrent Device Rating = 34.8 A > 20A»OK Circuit 3 Continuous Current= Imax x 1.25 = 12.6 A x 1.25 = 15.75 A Derate Ampacity = 90deg Rating of Conductor (T-310.16) x 90deg Temp Correction Factor (T-310.16) h x Conduit Fill Factor (T-310.15(B)(2)(a) =40Ax.87x1.00=34.8A So that, Derate Ampacity > Continuous Current = 34.8 A > 15.75 >> OK And, Derate Ampacity > Overcurrent Device Rating = 34.8 A > 15A»OK CIRCUITS 1-2 -SOLAR CIRCUIT MAXIMUM CURRENT: 13.5 A SOLAR CIRCUIT OPERATING VOLTAGE: 240V CIRCUIT 2 - SOLAR CIRCUIT MAXIMUM CURRENT:. 12.6 A SOLAR CIRCUIT OPERATING VOLTAGE: 240V . NEC 705.12 120%'Rule Calclulations Center Fed Panelboard Adjustment - N/A Supply Breakers + 20% <_ Busbar Rating Busbar Rating = 125A 80A Main 26A Solar + 20A Solar + 26A Solar 80A + 60A 5 125A * 1.20 140A:5 150A = OK Rev. Date Description T i s a Lp 44 q p ' • ' a �• •• ` :,� y - r ; i _ .. ,) � - ! �� Y � moi' If •. ! Y . • a I`j71j r!