Loading...
HomeMy WebLinkAboutB16-0273 063-360-014z O w o 0 Z O Z OV w co MINIMUM ER05I ON AND 5ED I MENT CONTROL5 FOR PROJECT5 D 15TURB I NG LE55 THAN ONE ACRE G-10 THE BMP'S (BEST MANAGEMENT PRACTICES) LISTED BELOW MUST BE IN PLACE DURING THE RAINY SEASON (OCTOBER 15 THROUGH APRIL 15) AND MAY BE REQUIRED AT OTHER TIMES BASED ON WEATHER AND SITE CONDITIONS THROUGHOUT THE YEAR. THE BMP'S LISTED ARE MINIMUM REGZU I REMENTS AND ADDITIONAL BMP'S COULD BE REG2U I RED BASED ON SITE CONDITIONS. I. STABILIZED ENTRY: PROVIDE MINIMUM 5" TO 6" FRACTURED ROCK 50' LONG x 15' HIDE BY b" DEEP OVER CONSTRUCTION GRADE FABRIC. 2. ALL SOILS TRACKED ONTO PAVED ROADWAYS MUST BE CLEANED ON A DAILY BASIS. WHEN STREETS ARE NET OR DURING A RAIN EVENT THERE SHALL BE NO TRACKING OF SOILS ONTO THE STREET. 5. WATTLES SHALL BE INSTALLED PROPERLY, BEHIND CURB OR SIDEWALKS. 4. ROCK BAGS (MINIMUM 2 PER SIDE) AT ALL DRAIN INLET LOCATIONS WITHIN 150' OF THE PROJECT SITE. 5. INTERNAL FILTERS SHALL BE PLACED INSIDE EACH DRAIN INLET. 6. TRASH BARS SHALL BE PLACED ACROSS THE BACK OF ALL DRAIN INLETS. 7. STABILIZE ALL DISTURBED SOILS IN THE FRONT YARD AREAS HI TH I N 15' OF THE BACK CURB OR SIDEWALK. (STRAW OR EROSION BLANKETS MAY BE USED FOR THIS APPLICATION) 8. STABILIZE ALL SLOPES WHERE EROSION COULD OCCUR AND CAUSE SILT RUN OFF. (STRAW, VISG2UEEN OR EROSION BLANKETS MAY BE USED FOR THIS APPLICATION) q. ALL PAINT, FUEL, CONSTRUCTION PRODUCTS ETC. SHALL BE STORED IN A COVERED LOCATION AWAY FROM SIDEWALK5 AND STORM DRAIN INLETS. 10. PORTABLE CHEMICAL TOILETS IF PROVIDED ON THE SITE MUST BE KEPT OFF OF STREETS AND SIDEWALKS AND A LEAST 50' FROM THE NEAREST STORM DRAIN. 11. ALL TRASH MUST BE COLLECTED AND STORED PROPERLY. DO NOT LET ITEMS SUCH AS DRYWALL MUD BOXES, PAINT BUCKETS, GLEANING MATERIAL CONTAINERS, ETC. COME IN CONTACT WITH ANY RAINFALL OR STORM WATER RUNOFF. 12. PROVIDE A DESIGNATED AREA FOR CONCRETE WASHOUT. HAY BAILS LINED WITH VISGtUEEN MAY BE USED FOR THIS APPLICATION. ROLLAWAY BINS MAY ALSO BE USED. ALL CONCRETE WASHOUT SYSTEMS SHALL BE PLACED OFF OF THE PAVED STREETS. 15. AFTER INSTALLATION OF THE ABOVE ITEMS ARE COMPLETE, A MAINTENANCE PROGRAM NEEDS TO BE DEVELOPED TO INSURE THE CONTINUED EFFECTIVENESS OF YOUR BMP'5. PROVIDE MINIMUM DISTANCE FROM FOOTING OF STRUCTURE OF 5FT NO CONSTRUCTION IN FROM ALL PORTIONS OF PRIVATE EASEMENTS Flood ®ne; SEWAGE DEPOSAL SYSTEM INCUDING LEACH AREA AND PITS ALL PORTIONS OF STRUCTURE TO BE OUT ,i,�,�,;ar� �c SEPTIC TANK NCLUDING FOOTINGS, �OUNDATIONS,IWALLS, EAVES AND ROOF PROPOSED 1500 GAL. SEPTIC TANK BUTTE rOUNTY MAR 17 Z016 ITV E LOPMENT $FIRVICES 157.18' PROPOSED PROPANE r A IL I l/ 0 0 0 z CD �' W 0co O 3 '� 0' -� CD Cr 0, O > CD - � (D �. CL 4 y Cn CD '0 U Cr CCD O 0)C/)N O n O CO 0 O a �. (D : CD -- .o O a c CD ' v c� o (DD 0 _°- CD r+ 3 CD - �. E' d (L CD N CD Q � a z� i ow _ja L it —� O CO OZCO OJF- F- N C/) C/)U Z cn r Z O N N cozcngaE wa w w w 0 00.0 -2Z 0 w w w 0 0 0 z a PROPOSED 1500 GAL. SEPTIC TANK BUTTE rOUNTY MAR 17 Z016 ITV E LOPMENT $FIRVICES 157.18' PROPOSED PROPANE r A IL I l/ 0 0 0 z CD �' W 0co O 3 '� 0' -� CD Cr 0, O > CD - � (D �. CL 4 y Cn CD '0 Cr CCD O 0)C/)N O n O CO 0 O a �. (D : CD -- .o O a c CD ' v c� o (DD 0 _°- CD r+ 3 CD - �. E' 3 aq CD N CD Q � a UNDERGROUND ELECTRICITY UNDERGROUND HATER WOODLAND PARK DR I VE ��i PEHII it bIL-tO2-7-S NFPA 58 BUTTE COUN-r( rE %EL0PMENT SE19VICES LPG TANK LOCATION Minimum distance �• � �� � � v �� � ��� � �� from property lines or Structures for F,""' Gallons or less, LPG Tank shall be -Feet i fi�� I C /Vie 71_Vk:;, D o NORTH 51 TE FLAN GREGORY A. PEITZ ARCHITECT 383 Rio Undo Ave. Chico, CA. 95926 (530) 894-5719 OWNER: RANDY 4 JOANN MOON ADDRESS: 1755 WALNUT TREE LN CHI CO, CA PHONE: (530) 5c12-5756 INFO: LOT 14 WOODLAND PARK DRIVE FOREST RANCH, CA 0.36 ACRES 063-360-014-000 SHEET of: ONE C ENERAL. NOTES G -I MISCELLANEOUS I. PROVIDE 4" HIGH x k WIDE STREET ADDRESS NUMBERS OF GONTRAST I NO COLOR, VISIBLE FROM STREETS. 2. FIRE SPRINKLER SYSTEM 15 REQUIRED PER CRO R313.3 OR NFPA 13D. FIRE SPRINKLER PLANS SHALL BE SUBMITTED UNDER SEPARATE COVER; SUCH PLANS MUST BE APPROVED, PERMIT ISSUED, AND HAVE INSPECTION BY THE FIRE MARSHALL PRIOR TO BUILDING GLO5INO IN. CONCRETE I. CONCRETE TO BE S SACK MIX, 2500 P51 ® 25 DAYS 2. REINFORCING STEEL TO BE INTERMEDIATE GRADE DEFORMED BARS -TYPE N OR 40. ROUGH CARPENTRY 1. INSTALL BLOGKING AS REQUIRED TO SUPPORT FIN15H HARDWARE AND FIRE STOPPING TO OUT OFF CONGEALED DRAFT OPEN I NGS AS REQU I RED BY GORES. 2. STRUCTURAL FRAMING SHALL BE DOUGLAS FIR TO THE GRADES INDICATED OR BETTER (WWPA GRADING RULE5) UNLE55 NOTED OTHERWISE. CONGEALED 4x BEAMS $ POSTS ......................... NO. 2 EXPOSED 4x BEAMS $ POSTS...............................NO. 1 lox BMS d POSTS.........................................................NO. 1 2x JOISTS AND RAFTERS........................................NO. 2 STUD, SILLS, PLATES...................................................NO. 2 SILLS ON CONCRETE...................................................PTHF MISC. FRAMING NOT NOTED....................................NO. 2 3. PLYWOOD SHALL BE OF THE DF-51ONATED GRADE AND SHALL MEET THE REQUIREMENTS OF THE U.S. PRODUCT STANDARDS P5 1-53. 4. NAILS AT PLYWOOD PANELS SHALL HAVE s/8" EDGE DISTANCE AND SHALL NOT PENETRATE FAGS -PLY. 5. NO PIECE OF PLYWOOD ROOF, FLOOR OR WALL 5HEATHING SHALL BE LE55 THAN 12" IN LEAST DIRECTION. 6. FRAMING HARDWARE SHALL BE SIMP50N STRONG -TIE OR APPROVED EQUAL, W 1 TH CONNECTORS AS SPECIFIED 7. PROVIDE 50L I D BEARING CONTINUOUS FROM ALL BEAMS TO FOUNDATION. e>. PROVIDE FIRE BLOCKING IN CONGEALED SPACES VERTICALLY AND HORIZONTALLY IN ACCORDANCE w/ 2013 G.R.G. SECTION R302.11. cf. FASTENERS FOR PRESERVATIVE TREATED AND FIRE TREATED WOOD SHALL BE OF HOT DIPPED ZING COATED GALVANIZED STEEL, SILICON BRONZE OR COPPER. THE GOATI NG WE I5HT5 FOR ZING COATED FASTENERS SHALL BE IN ACCORDANCE w/ A57MA 153. 2013 G.R.G. SECTION R317.3. 10. BEARING WALL HDRS. SHALL BE 4x10 #2 OR 6x8 D.F. #1 MIN., TYP., U.O.N. I I . EACH SIDE OF TOP PL. LAP SPL I GE SHALL HAVE (5) I6d (5�" x .135",P) MIN., TTP. PLUMBING I. THE AGGREGATE AREA OF PLUMBING VENTS SHALL BE 12.5150. INCHES, MIN. 2. GAS FIRED WATER HEATER TANKS SHALL BE FASTENED TO THE ADJACENT FRAMING w/ I6 GAUGE METAL STRAP (0516 OR EQ) w/ MIN. 2" LONG #12 WOOD SCREWS ® 4" ABOVE CONTROLS AND WITHIN 12" OF THE TOP OF THE TANK. 4. SHOWER AND TUB -SHOWER COMBINATIONS SHALL BE PROVIDED w/ INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE. 5. INSTALL A 4" DRAIN FOR BUILDIN55 PROVIDING MORE THAN (3) WATER CLOSETS. 6. HORIZONTAL DRAINAGE PIPING SHALL BE 2% MIN. SLOPE. 7. SHOWER AND TUB/5HWR WALLS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE o/ A MOISTURE RESISTANT UNDERLAYMENT TO A HEIGHT OF 72" ABV. FINISH FLR. DRAIN INLET, PER ORO 8307.2 MECHANICAL I. DRYER DUCT TO BE MIN. 4" (P TO THE OUTSIDE, EQUIPPED WITH A BACK -DRAFT DAMPER. 4%) DUCT LENGTH 15 LIMITED TO 14' WITH 2 ELBOWS. OTHER LENGTHS OR SIZES AS PERMITTED OR REQUIRED BY THE MANUFACTURE'S INSTALLATION INSTRUCTIONS MUST BE APPROVED BY BUILDING OFFICIAL. (SUBMIT REQUEST FOR MODIFICATIONS) 2. SINGLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLINGS AND RESIDENTIAL OCCUPANCIES. REVIEWED FOR CODE COMPLIMCE �/ FOR COMPLIANCE VVIM L��,�'3 CALL rNIA BWAING CODES Lv! r'-� CA,L1aropmA ELECPP.ICAL CO1� (nscn ON rit l�rn ❑ 2013 CAI1FORWA PLUM7"ING CODES ❑ 2"13 CAL 0 ^NIA EDGY CODES ❑ 2013 CALWOPNIA h!ECAANICAL COVES ❑,_,�'3 CALITOM lIA BUILDING CO!)ES-S=..UCrU.-.AL O -MY fL 2013 CALi'E ORNIA G* EY BUIZUM-G STAN9lA�S CO't ❑ � CALL RXIA FIRE CODM 2"13 CAL1rO"MA liEfifiII1n IAL COD" Plan review approval of documents does net =entr^riie construction to proceed In viclatien of n1y federal, state, nor local regulation. BY:..� ATE: Comply with 2013 CRC Section 8327 Materials and construction methods for exterior wildfire BUREAU VERITAS NORTH AMERICA, INC. exposure for Current information on approved materials from Cal fire / Californi Di ' ' f F C I'f a iwsion o orestry see a i orn BASELINE WATER USE - 5 BEDROOM RESIDENCE m DROP-IN TUB w/ TILE PLATFORM 6.75' 1640 (( )) SH fl�l�l■■IE1�.� m TILE 5HWR. 3414 OLA55 BLOCK N z I'-6" 3 �o Q N I h`bU• � ?k ID �MSTR. BATH el' GLC. TILE T r 4.0' 4 A/C UNIT I ESK _ I 201 ; AWN j tu III A 4 SOFFIT -3y2"xl3y12" 24F -V4 GLB. GOV�R�D PATIO 'LL L INGLC. GONG. �I I S.G.D. 4040 SH 000 DW IED - KITCHEN m el' GLC. HDWD �DININC CLO 4x4 TRIMMER POST, TTP. OF (6) 4 6x8 H FIXTURE ,TYPE FLOW RATE DURATION REAR COVR'D I NATER Hr=ATF-R MANDATOR -1' IF.ATURES HATPORCH INDIVIDUAL DUAL DWELL NG UNITS SHALLNO AIN: OR THE ANE HATER FOLLOWINGHEATERS TOGOMPONEN SERVE cl' GLC. I. A 120V ELECTRICAL RECEPTACLE THAT 15 WITHIN 3 FEET FROM THE WATER GONG. HEATER AND ACCE551BLE TO THE WATER HEATER WITH NO OBSTRUCTIONS 2. A GATEGORY II I OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE TANKLESS WH w/ MIN. BETWEEN THE OUTSIDE TERMINATION AND THE SPACE WHERE THE WATER 100 SQ. IN. COMB. AIR HEATER IS INSTALLED VENT IN N. CO AND 3. A CONDENSATE DRAIN THAT 15 NO MORE THAN 2 INCHES HIGHER THAN THE CEILING BASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE 4. A GAS SUPPLY LINE WITH A CAPACITY OF AT LEAST 200,000 BTU/HR. .'DRY c1' GLC. TILE 6.5' 4050 SH _ _ - 3068 BEDROOM 3 Y� LITE �'-6" .D cf' GLC. HDWD 4'-4" 7'-8" t -DRYER DUCT. SEE MECHANICAL -O„ HDWD i Yz LITE W r NOTE I UNDER _ _ _ _ _ _ GENERAL NOTES. 2468 REF 21.25' NOTE: -1 GARAGE WALLS AND CLO. FIN. TO BE MIN. 2" GYP. BD. I I FOLD DN. iIci.O' 5'-0'2-6" FLUSH I IRON BD D ry�D tu = 2868 = BAR - - SUB-PANELi 1�4 j2`I' G.O. DBL. -0 68 tt tY OVEN0 ( , 2868 - - - - - - - \ / I 1 C ARAE I u �, 15076 G.O. " " SHELVES - ci' GLC. 3 -6 2 -O 4 O LG. BREAK 2x6 WALL 22 x30 ATTIC J Q SHELVES 5 P Q LINE ACCESS 2868 - - - , GONG. tV 28 STEP UPPER m 2868 CABINETS - ci' GLG. PROVIDE 100 SQ. IN. O - - 0 VENT IN DOOR MIN. 4'-`f��� � 5'-0" 68 (2) 3068 2868 MIN. 1%" ABOVE TOILET � - -� THICK S.G. w/ Provide glulam certificate at time 3068 I I HALL. O % SELF CL5R. 4 of frame inspection to field I 4032 GFM BELT -DRIVE WHOLE C.O.V Q' CLO. 2 " - LATCH inspector HOUSE FAN w/ R4.2 IN5UL., w/ 1 - MSTR. VARIABLE SPEED RHEOSTAT. 3'100 -5k, - 3'-0" V-6" 3' -II" HDWD 3'-10 211011 '� � BEDROOM 1 L NE BREAK � 2468 5 � P - 668 S � P =1cv 2x6 STUDS CLO. HDWD Q civ + 3050 SH 3050 SH 3050 5H 2 2 NT 2.5 = 3E �N m = 5.0' OTE: WINDOWS TO HAVE HD. HT., TYP., U.O.N. _ APPROVED PLANS.AND PERMIT SHALL BE ON SITE FOR ALL INSPECTIONS FLOW RTE DURATION A DAILY MINIMUM HEATING EFFIGIENGY: 4. REQUIRED HERS VERIFICATION: � DAY 5 8 P- S$ P - 8 MIN. x I x 4 = 80 SHELVES 2.2 x 25 MIN. m m 2468 W.I .G. CARPET d)� 4 = 2 A 4 SOFFIT -3y2"xl3y12" 24F -V4 GLB. GOV�R�D PATIO 'LL L INGLC. GONG. �I I S.G.D. 4040 SH 000 DW IED - KITCHEN m el' GLC. HDWD �DININC CLO 4x4 TRIMMER POST, TTP. OF (6) 4 6x8 H FIXTURE ,TYPE FLOW RATE DURATION REAR COVR'D I NATER Hr=ATF-R MANDATOR -1' IF.ATURES HATPORCH INDIVIDUAL DUAL DWELL NG UNITS SHALLNO AIN: OR THE ANE HATER FOLLOWINGHEATERS TOGOMPONEN SERVE cl' GLC. I. A 120V ELECTRICAL RECEPTACLE THAT 15 WITHIN 3 FEET FROM THE WATER GONG. HEATER AND ACCE551BLE TO THE WATER HEATER WITH NO OBSTRUCTIONS 2. A GATEGORY II I OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE TANKLESS WH w/ MIN. BETWEEN THE OUTSIDE TERMINATION AND THE SPACE WHERE THE WATER 100 SQ. IN. COMB. AIR HEATER IS INSTALLED VENT IN N. CO AND 3. A CONDENSATE DRAIN THAT 15 NO MORE THAN 2 INCHES HIGHER THAN THE CEILING BASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE 4. A GAS SUPPLY LINE WITH A CAPACITY OF AT LEAST 200,000 BTU/HR. .'DRY c1' GLC. TILE 6.5' 4050 SH _ _ - 3068 BEDROOM 3 Y� LITE �'-6" .D cf' GLC. HDWD 4'-4" 7'-8" t -DRYER DUCT. SEE MECHANICAL -O„ HDWD i Yz LITE W r NOTE I UNDER _ _ _ _ _ _ GENERAL NOTES. 2468 REF 21.25' NOTE: -1 GARAGE WALLS AND CLO. FIN. TO BE MIN. 2" GYP. BD. I I FOLD DN. iIci.O' 5'-0'2-6" FLUSH I IRON BD D ry�D tu = 2868 = BAR - - SUB-PANELi 1�4 j2`I' G.O. DBL. -0 68 tt tY OVEN0 ( , 2868 - - - - - - - \ / I 1 C ARAE I u �, 15076 G.O. " " SHELVES - ci' GLC. 3 -6 2 -O 4 O LG. BREAK 2x6 WALL 22 x30 ATTIC J Q SHELVES 5 P Q LINE ACCESS 2868 - - - , GONG. tV 28 STEP UPPER m 2868 CABINETS - ci' GLG. PROVIDE 100 SQ. IN. O - - 0 VENT IN DOOR MIN. 4'-`f��� � 5'-0" 68 (2) 3068 2868 MIN. 1%" ABOVE TOILET � - -� THICK S.G. w/ Provide glulam certificate at time 3068 I I HALL. O % SELF CL5R. 4 of frame inspection to field I 4032 GFM BELT -DRIVE WHOLE C.O.V Q' CLO. 2 " - LATCH inspector HOUSE FAN w/ R4.2 IN5UL., w/ 1 - MSTR. VARIABLE SPEED RHEOSTAT. 3'100 -5k, - 3'-0" V-6" 3' -II" HDWD 3'-10 211011 '� � BEDROOM 1 L NE BREAK � 2468 5 � P - 668 S � P =1cv 2x6 STUDS CLO. HDWD Q civ + 3050 SH 3050 SH 3050 5H 2 2 NT 2.5 = 3E �N m = 5.0' OTE: WINDOWS TO HAVE HD. HT., TYP., U.O.N. _ APPROVED PLANS.AND PERMIT SHALL BE ON SITE FOR ALL INSPECTIONS REQU I RED 20% REDUCTION IN BASELINE WATER USE CALCULATION TABLE FIXTURE TYPE FLOW RTE DURATION A DAILY MINIMUM HEATING EFFIGIENGY: OCCUPANTS REQUIRED HERS VERIFICATION: � DAY SHOWERHEAD5 (RESIDENTIAL) 2.5 x 8 MIN. x I x 4 = 80 LAV. FAUCETS (RESIDENTIAL) 2.2 x 25 MIN. x 3 x 4 = 6.6 KITCHEN FAUCETS 2.2 x 4 MIN. x I x 4 = 35.2 GRAVITY TANK -TYPE N.C.'s 1.25 x I FLUSH x 3 x 4 = 15.36 TOTAL BASELINE WATER USE (BWU) = 137.16 141 (BWU) x .80 = ALLOWABLE WATER USE = 112.8 REQU I RED 20% REDUCTION IN BASELINE WATER USE CALCULATION TABLE FIXTURE TYPE FLOW RTE DURATION A �gEg MINIMUM HEATING EFFIGIENGY: OCCUPANTS REQUIRED HERS VERIFICATION: PER DAY SHOWERHEADS (RESIDENTIAL) 1.85 x 8 MIN. x I x 4 DUCT INSULATION: R6 LAV. FAUCETS (RESIDENTIAL) 2.0 x .25 MIN. x 3 x 4 = 6 KITCHEN FAUCETS 1.5 x 4 MIN. x I x 4 = 24 GRAVITY TANK -TYPE W.C.'s 1.28 x I FLUSH x 3 x 4 = I Q.2 ALLOWABLE DAILY WATER USE: 112.8 GALLONS PROPOSED DAILY WATER USE: 104.56 GALLONS NOTE: SEE WATER EFFICIENCY AND CONSERVATION SECTION AT CALGREEN MANDATORY MEASURES NOTES ON THE CAL OREEN SHEET C LINEN , LINEN N �Q ,7' N ' I 10' GLC. - - 0) L=:J8 2668 2668 % m 5y2"x13y.2 24F -V4 GLB. HDR. w/ DBL TRIMMERS BATH _ HDWD 3 BUILT- INS ( ENTRY GLC.16080 O.G.D.0,��3tuTILE -=1cv , 4 7.1 4.5' + `�' 4.5'r'+ `�� D6L pU2 =1� 5H�ARk4ALL SCHEDULE: ZERO -CLEARANCE GASFIREPLACE w/ NON-COMBUSTIBLE ( I HD2X 2040 2040 SH 2-2X4 HEARTH. INSTALL PER MFR. Q = SH 3'-101 " 4'-2 " SYMBOL= SHEARWALL: - SPEC. PROVIDE INSTALLATION BENCH Nd 5 -6 3 -I f g/8" GDX PLYWD. OR OSB w/ 8d'5 MANUAL ® SITE 3'6 I x N = O O O - -uv m Q ® 6", 12" O.G., I6d SINKER SILL � 4'-0" "' o BEDROOM 2 � I 4x12 HDR. `ry 3068 6 5.0 r el' CLO. O s/8" GDX PLYWD. OR OSB w/ Sd'5 - -- - -- - --- - - -- -- 5.0. HDWD Q ® 4", 12" O.G., w/ 4x STUDS 3050 H 6050 FX 3050 SH O ADJ. PANEL SPLICES, I6d SINKER SILL NAILS ® 5Y2" 0.0 Ici 3 GOVR'D 2'-3 1 50505H 3050 SH g/8" GDX PLYWD. OR OSB w/ 8d'S IL I I I p - Q3 ®3", 12" O.G. w/ 4x STUDS ®ADJ. LL PORCH I O PANEL SPLICES, I6d SINKER SILL 1 I 10' T$G CLO. I I NAILS ®4Yy O.G. tL GONG. 3y2 "x12" 24F -V4 GLB. 10 1 �j/� � V N 1 f ' � O ®/v Aaa2 , 12" O.C. W 4x STUDS ® ADJ. ---------------- ----------- PANEL SPLICES, I6d SINKER SILL - - - - - - - - _ - SOFFIT - - - BUILDING PERMIT# I _ NAILS ® 2V2" O.G. - - - - - - - - - - - ASSESSOR'S PARCEL# F/ h 237360- U PEI BUTTE COUNTY DEVELOPMENT SERVICES I. NAILS SHALL BE COMMON NAILS (2V2"x.131 "), TYP., U.O.N. CODE REVIEWED CE 2. ALL PLYWOOD PANELS SHALL HAVE ALL EDGES BLOCKED. m GOVERNING CODES: 2013 GBG, 2013 GRG 2013 CEG, 2013 GPO, 2013 GMC, 2013 CFC, 2013 CALIF. HEALTH $ SAFETY CODE AMENDMENTS 2013 CALIF. ENERGY CODE EFFICIENCY STANDARDS, ZONE 11 2013 CALIF. ACCESSIBILITY REQUIREMENTS AMERICANS w/ DISABILITIES ACT, 2012 EDITION NFPA 101, 2013 CGBSC OCCUPANCY GROUP: GROUP: R3 / U ALLOWABLE HEIGHT AND BUILDING AREAS (TABLE 503) ALLOWABLE AREA: UNLIMITED ACTUAL FLOOR AREA: 3188 S.F. ALLOWABLE 5TORY/HEIGHT: (3) STORIES / 40'-0" ACTUAL 5TORY/HEIGHT: (1) STORY / lei' -O" CONSTRUCTION TYPE: TYPE VB AUTOMATIC SPRINKLER: REQUIRED WILDLAND URBAN FIRE INTERFACE: REQUIRED, SEE WUI SHEET .. 9 A V DATE . ��- Lo 16 Py � t� co � ''-°" SSD 12'-0" 25'-0° I'E1�'IBUED EGFR ODE CT11PLIA1ICE " 2P I' These p12ns and documents have been reviewed for compliance with the applicable code requirements PLAN j�� Title 24 requirements refer to e ....,..ri. i FLOOR I- LA `� attached energy certificate of compliance hot be held to permit or be an approval of any for requirements for this building and violation of applicable codes and standards nor HERS relieve the owner, design professional o recordor verification requirements contractor of compliance with applicable codes and standards. Plan review of documents does not authorize construction to proceed in violation of any federal, state, nor local regulation. NOTE: TH 1 S PROJECT 15 LOCATED IN A WILDLAND URBAN 1 NTERFACE AREA. SEE SHEET NUI FOR REQU I REMENT5 Comply with California Civil Code Section 1101.1. Installation of water - conserving plumbing fixtures. See 7++a,t- tmPnf fr%r rPni IirP.m Ant G - BUREAU VERITAS NORTH AMERICA, INC. Fire sprinkler permit will be required i �� 5 �� Complete construction Post Debris Recovery for this structure separate permit will final report and V.O.C. documentation and be required to be issued prior to rough IPE`,,U VICTITRS t"ORTI•? A1;9ERICA, IIYC� submit to Building Division prior to final building inspection frame inspection v v vvv� SCOPE OF NORK: NORTH CONSTRUCT NEW RESIDENCE. Eli I= rtralpy MINIMUM TITLE 24 REQUIREMENTS: Date: AREAS: A 5-14-16 MINIMUM HEATING EFFIGIENGY: 955yo AFUE REQUIRED HERS VERIFICATION: LIVING AREA: 201650. FT. MINIMUM COOLING EFFIGIENGY: 14.0 SEER -DUCT LEAKAGE VERIFICATION C ARAC E AREA: 613 50. FT. DUCT INSULATION: R6 -HVAC: VERIFY AIRFLOW (550)1 VERIFY EER, COV. PORCH AREA: 55Ci 50. FT. RADIANT BARRIER ROOF SHEATH I NO : REQ'D VERIFY FAN WATT DRAW, BUTTE �n � a, WATER HEATER EFFICIENCY: 82 VERIFY REFRI C ERANT CHARC E COUNTY �U,_ -IAQ FAN: VERIFY 50.16 GFM MAR 17 2016 DRE C'LT7z1;- C;N Revision: Date: By: A 5-14-16 EO 01)N r` H �n � a, 0 �U,_ • C;N .a in � I�1 d U U CU w e0 C W o ••I M 00 M W O(:4 WOQ� Z I� V1 O Z � W 1.4 Q4Co� � O Q Q4 O E-l rO I--�-1 E:4 r,,° A'c���F * No. 212 /MOON RESIDENCE 2016 Date JANUARY 2016 Scale Drawn 05TROV5K I Y Job 15-2126 Sheet Of Sheets 2 CL N M TA �f cfl If y . 4 i 601.5 F FRONT ELEVATION SHINGLES F I BER -GEMENT BOARD BOARD t BATT. SIDING TYP. ® GABLE ENDS. NMI 90-11 Mli ini MEN 0 MEN 0 mom on 111i E[EN 01 OEM ryVERI F'r' Pq/ OMER 0ON0. FOR PEEP 50REED LAYERS ORAVE D BLD6. PAPERSYSTEM OR Ea. (ER 552) Exterior masonry veneer and stone Shall Comply with 2013 CRC Section R703.7 Requirements REAR ELEVATION 1/4" = 1'-0" EXTERIOR PLASTER Stucco Shall comply with 2013 CRC Section R703.6 Requirements. 2x10 FASCIA w/ 1 ..�2 �ra l iw �rvl7 2x10 FA501 A Surface Drainage shall comply with 2013 CRC section R401.3 minimum 5% (6 inches" in 10 feet) slope away from foundation walls RI5HT ELEVATION 1/4" = 1'-0" Comply with California State Fire Marshall Requirements for roof covering, valleys & gutters, attic ventilation, exterior wall openings, exterior walls, windows, decks and under floor venting -2013 CRC Section R327 PERMIT#1b - DZ-`� BUTTE COUNTY DVE ELOPMi=NT SERV_ ICES EVIEVVED FOP C0 E a0e° I LI AiM DATE 3 Zg to! 6 Pv AMA ottgjLYIED FOR CODE CWMIPLIAECE ilMl 2 5 2016 CUREAU VFRITAS I'ORTH, AMERICA, IMC. ReAslon: I M0111M Mill ---- IN� LLMill 1�1110 N u7 i 601.5 F FRONT ELEVATION SHINGLES F I BER -GEMENT BOARD BOARD t BATT. SIDING TYP. ® GABLE ENDS. NMI 90-11 Mli ini MEN 0 MEN 0 mom on 111i E[EN 01 OEM ryVERI F'r' Pq/ OMER 0ON0. FOR PEEP 50REED LAYERS ORAVE D BLD6. PAPERSYSTEM OR Ea. (ER 552) Exterior masonry veneer and stone Shall Comply with 2013 CRC Section R703.7 Requirements REAR ELEVATION 1/4" = 1'-0" EXTERIOR PLASTER Stucco Shall comply with 2013 CRC Section R703.6 Requirements. 2x10 FASCIA w/ 1 ..�2 �ra l iw �rvl7 2x10 FA501 A Surface Drainage shall comply with 2013 CRC section R401.3 minimum 5% (6 inches" in 10 feet) slope away from foundation walls RI5HT ELEVATION 1/4" = 1'-0" Comply with California State Fire Marshall Requirements for roof covering, valleys & gutters, attic ventilation, exterior wall openings, exterior walls, windows, decks and under floor venting -2013 CRC Section R327 PERMIT#1b - DZ-`� BUTTE COUNTY DVE ELOPMi=NT SERV_ ICES EVIEVVED FOP C0 E a0e° I LI AiM DATE 3 Zg to! 6 Pv AMA ottgjLYIED FOR CODE CWMIPLIAECE ilMl 2 5 2016 CUREAU VFRITAS I'ORTH, AMERICA, IMC. ReAslon: Date: By: N u7 • CNkn .� Iii U � CJ iv a r l U W W o a ' ` 00 M W 0 WoQ� � n C Q Imo' Q O O rO w [� di ARC ?'Y * No. C N� 283 RE 7/17 100N 2016 Date JANUARY 2016 Scale Drawn05TROY5KIY Job 15-2126 Sheet Of Sheets E a 00 M e-1 O N M P.T. SILL W/ Y2 " DIA. x 12" A.B. ® 6' O.G. AND 12" MAX. FROM ENDS W/ 5"x3"x.22cI" PLATE WASHERS, TYP. itCONO. SEE FOUNDATI OBN, PLAN cn� GARAGE FOOTING F-0 I " = P-0 P.T. SILL W/ Y2 " DIA. x 12" A.B. ® 6' O.G. AND 12" MAX. FROM ENDS W/ n " _— _ —.1 .-a . — — w —1 1"— - -rare I - STORY FOOT I NO F- I 1 " = 1'-0 6" x 6" MIN. PLYWD. GUSSETS EA. SIDE w/ (5) Sd'5 EA. TO POST $ OIRDER--\ NAT. GRADE I • dI NI d) x SEE FOUNDATION PLAN FOR FRAMING SIZES 4x4 POST TOE -NAIL TO REDWD. BLOCK w/ (5) 5d'S MIN. PRECAST GONG. PIER 2" EMBEDMENT 1= I I=1 I I 11 I - :I = 1=III: = 1-1 I I, „I 18" SQ. F I ER FOOT I N5 F-52 III = 1'_0 4" GONG. SLAB o/ POST, SEE FLR. PLAN BASE, SEE FLOOR PLAN FOR HOT. IN SEE FDN. PLAN FOR RELATION TO POST BASE TYPE FIN15H FLOOR. #4 ®4'-O" O.G. • • 0 000°00 0 0 NAT. GRADE0 0 0 0 0 op�b 0 0 FINISH GRADE 000 00 0 0 GRANULAR FILL -" .I � I -III -III -III -I I I� 6:� III -I I i -III -III -III -III -III -I � I z -I I �=III=III=1 I I I I-III-III-III=1 I ll=1 11=1 11- � I I I-111, ;,III -III MIN° . I I I -I I I -I I I -I I I -I I I -III- I I S -, ,, d _ I it i 111=1Ti- _ z -1 I I=1 I I _ #4 TOP �-I I I l l l l l l I I—I I I BOTTOM „III„ I, 12" FOROH FOOT I NO 5-1 f LINE OF STEMWALL BEYOND FELT STRIP DRIVEWAY SLAB --� a a. 12" MIN. TYP. U.O.N. TYP I GAL EASED EDGE GONG. 5LAB, SEE FOUNDATION PLAN CONT. #4 TOP 4 BOTTOM m� GARAGE DOOR OFF -N I NO F-141 I" = I'-0" F-14 I " = 1'-0" FOUNDATION PLAN 1/4" =pFLv�', :.-- __ _ &16-_027_5 EVIE'� ED FOR CODE COMPLIA11CC 3U`f'E COUi�.��Y r�� o'r')E: r ..I DATE�'GI Z�1 r',Y FOUNDATION NOTES I. PROVIDE 18"x24" MIN., SCREENED U.F. ACCESS 2. UNDER FLOOR VENTING: 2027 / 150 = 13.52 S.F. OF NET FREE AREA. PROVIDE (1) IS"x24" CRAWL HOLE ® 1.6 50. FT. PROVIDE (40) 5Y2"x14Yz" UNDER FLOOR VENTS ® 0.3 50. FT. EACH. TOTAL UNDER FLOOR VENTING PROVIDED: 1cI.60 50. FT. PROVIDE A VENT V FROM EACH CORNER. 3. GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL SLOPE AWAY FROM THE BUILDING AT A SLOPE OF NOT LESS THAN 6" WITHIN THE FIRST 10 FT. (5% SLOPE). PER 2013 GRG SECTION R401.3 4. ALL FOOTINGS SHALL BE FOUNDED ON UNDISTURBED NATIVE SOIL. Revision: Date: By: N CN CN WE 00 P1 48'-6" � A V Mei U � "` Ocl Ucl � o C W F+� o fn 04 M 14'-6" 0 H :2-71-011 V I'-O"ol H �4 H V1 0 C � 24" 50. x 12" DP. FTG. O O H V) I4 `� w /4" I 0 0 4-1 AA. cA��F GONG. SLAB w/ #4 * N� N C21283 N. 7/17 FrCA�- MOON 2016 Date JANUARY 2016 BAR ® 2'-0" O.G. DrawnO5TROV5KIY Job 15-2126 Sheet Of Sheets w � BOTH WAY5 o/ BASE _ O �b - 3'x3' MIN. GONG. LANDING, 6 '13/4" MAX. BELOW TOP OF DR. THRESHOLD, TYP. 5 ALL EXTERIOR b S IN -SWINGING DOORS p 40" 50. x 12" DP. -44- FTG. w/ #4 BAR ® 7" cq d)MIN. il 3'x3' GONG. LANDING, O.G. W BOTH AY5 m m 14 -6 CONFIRM w/ OWNER tt �j6 dJ 40 SQ. x 12 DP. F� 0 -1— FTG. w/ #4 BAR ® T' r ( IO.G. BOTH WAYS - 0 m I 5 –I –1 –1 -PI.O. FORTMP. r I– F _1 F -I Le, �' O" DR. 4'-Q" 4'-a"3' L J L J J L J L J3 I —1 F -1 I- F- -I I IF -I IF -1 F --i IF --1 I L J L J L J L J L J L L J L J71 41-511 01 ,�jl 01 e i I Z'-ONC. t- -1 I SLAB w/ #3 BARto cV 2O O.G. BOTH WAY5 o/ 211 SAND o/ 6 MIL. VB (w/JO I NTS I i F –� F 7 F –I F 7 F –11F –11F –I F 7 1-7 F- -I r- –1 LAPPED 6" MIN.) o/ 4" BASE - O t = m – L J L J L J L J L J L J L J L J L J L J L J L J L J I L.11 11 11 4-10 't ll 4-10 4-10 4 1 -10 n II 11 11 11 4-10 4-10 4-10 4-10 4-10 II 4-10 II 4-10 11 4-10 PROVIDE Q 15"x24" CRAWL HOLE MAX. 4x6 GIRDER, TYP. .21-01 1- 7 F -11 F 7 7 F _1 F 7 F- -I IF -I F --'I IF I I LJ LJ LJ LJ LJ LJ LJ LJ LJ LJ LJ LJ - R.O. FOR I6' " 5 —0110.0. i_ o i_ a i_ n 41-1011 41-1011 41-1011 �_ a i_ n i " i_ n i_ n 4'-10" 4'-10' 41-1011 4'-10" 41-1011 i_ n 4'-10" i_ n 41-1011 �_ a 4 10 i_ u 2 3 I �� GAR. DR. MAX., TYP. m �— s ---L J 6�\� TMP. I 2'-3"�� `9 SSTBI6 55TBI6 6 2 s i6 1' 24" 50. x 12" DP. I I I 5 �'o �b to � FTG. w/ #4 BAR ® '7" O.G. BOTH WAYS 4'-4�" ��� _r -1 55'�$I6 -1 1 —I -1 F _1 F F —1 _ 5 � LJ LJ J LJ LJ LJ LJ LJ TMP' 5 _ 3'x3' MIN. GONG. LANDING,`�S 3 " W TOP OF 7 /4 MAX. BELO I ( s ° DR. THRESHOLD, TMP. ® I I I I =� 28" SQ. x 12" DP. FTGS. w/ #4 M I ►n ALL EXTERIOR I � - O I - O m BAR ® 'i O.G. BOTH WAYS s 5,x,6 L IN -SWINGING DOORS ( f SSS IL JI �s I �4" tu II 6 = GONG. SLAB w/ #4 O = BAR ® 2'-0" O.G. 5 I I r %Z BOTH WAYS o/ BASE --,—,in t II— Q ❑ El I 4c N-24" 4 24" 50. x 1, 12 50. x DP. FTG. 24" 50. x TYP. 12" DP. FTG. 12" DP. FTG. 5 I6'-32" 1'-10" 10 01 5'-6" I5'-7" ell -III ' -I" 25'-0" lo C151 -011 LINE OF STEMWALL BEYOND FELT STRIP DRIVEWAY SLAB --� a a. 12" MIN. TYP. U.O.N. TYP I GAL EASED EDGE GONG. 5LAB, SEE FOUNDATION PLAN CONT. #4 TOP 4 BOTTOM m� GARAGE DOOR OFF -N I NO F-141 I" = I'-0" F-14 I " = 1'-0" FOUNDATION PLAN 1/4" =pFLv�', :.-- __ _ &16-_027_5 EVIE'� ED FOR CODE COMPLIA11CC 3U`f'E COUi�.��Y r�� o'r')E: r ..I DATE�'GI Z�1 r',Y FOUNDATION NOTES I. PROVIDE 18"x24" MIN., SCREENED U.F. ACCESS 2. UNDER FLOOR VENTING: 2027 / 150 = 13.52 S.F. OF NET FREE AREA. PROVIDE (1) IS"x24" CRAWL HOLE ® 1.6 50. FT. PROVIDE (40) 5Y2"x14Yz" UNDER FLOOR VENTS ® 0.3 50. FT. EACH. TOTAL UNDER FLOOR VENTING PROVIDED: 1cI.60 50. FT. PROVIDE A VENT V FROM EACH CORNER. 3. GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL SLOPE AWAY FROM THE BUILDING AT A SLOPE OF NOT LESS THAN 6" WITHIN THE FIRST 10 FT. (5% SLOPE). PER 2013 GRG SECTION R401.3 4. ALL FOOTINGS SHALL BE FOUNDED ON UNDISTURBED NATIVE SOIL. Revision: Date: By: N CN CN WE 00 P1 � A V Mei U � "` Ocl Ucl � o C W F+� o fn 04 M 0 H WoQ� V N�y4 H �4 H V1 0 C � O H V) I4 `� w F -i 0 0 4-1 AA. cA��F * N� N C21283 N. 7/17 FrCA�- MOON 2016 Date JANUARY 2016 Scale DrawnO5TROV5KIY Job 15-2126 Sheet Of Sheets 2 a M IWA ei 0 N ri M u ROOF SHEATHING ® O.H.S SHALL BE FIRE -RES 15TANT PLYND. OR 055 - SOLIDS BLOOKI NO SHEARPLY, SEE PLAN Er" PLY. L MIN. 5'-0" LONG 0516 STRAP w/ �A55 ® 4'-O" O.G., TYPi:z� U.O.N. AS SHOWN, IF NECESSARY) E. N I" MIN. AIR SPACE TO INSULATION VENTS F-A\/F- DETAIL_ I " = I'-0" FASC I A, SEE ELEVATION ROOF PLY E.N. SIDING O.E. TRU55 SHEARPLY, SEE PLAN - E.N. E.N. E.N. A55 ® 4'-0" O.G., TYP., U.O.N. OABL E F.ND R-12 1" = I'-0" GIRDER TRUSS W 2x STUDS ® 16" O TRUSS 5TRAF 'J" DIA. THREADED ROD F.A.U. 1 " = 1'-0 1 �" x 1 �" ANGLE w/ (2) 4" x 2" LONG LAG BOLTS INTO TOP CHORD OF TRUSS, T -i -P. 4So 1�" x Ik" ANGLE w/ NUTS SEISMIC, RESTRAINTS AND WASHER, TYP. (4) DIRECTIONS k4ATERTISHT CORROSION RESISTANT METAL DRIP PAN F.A.U. MOUNT I NO AC -5 5/4" = 1'-0" .__ ROOF PLY C.N. L MIN. 5'-0" LONG 0516 STRAP w/ MIN. (15) Sd'S EA. END (SKEWED DRAG TRUSS AS SHOWN, IF NECESSARY) PLAN VIEW TRUSS, NAIL ROOF PLY TO E.N. SHEARPLY, SEE PLAN TOP CHORD W/ 8d's ® 6" O.G. DOUBLE 2x TOP PLATE 18" 0516 STRAP w/ N (IS) 8d'S MIN. EA. END W 2x STUDS ® 16" O TRUSS 5TRAF 'J" DIA. THREADED ROD F.A.U. 1 " = 1'-0 1 �" x 1 �" ANGLE w/ (2) 4" x 2" LONG LAG BOLTS INTO TOP CHORD OF TRUSS, T -i -P. 4So 1�" x Ik" ANGLE w/ NUTS SEISMIC, RESTRAINTS AND WASHER, TYP. (4) DIRECTIONS k4ATERTISHT CORROSION RESISTANT METAL DRIP PAN F.A.U. MOUNT I NO AC -5 5/4" = 1'-0" .__ ROOF PLY C.N. Date: By: DRAG TRUSS EE ROOF PLAN OR A55 SPAGINO rFLOCATIONS r E.N. SHEARPLY, SEE PLAN DRAG TRU55 R-Ci0 1 " = I'-0 CONT. 0516 ROOF PLY. STRAP w/ Sd'5 ® 4" O.G. A55 ® 4'-0" U.O.N. E.N -71 2x4 SOLID BLKO. SHEAR TRANeFER ROOF PLY. HALL BEYOND, - SEE DETAIL 6-4 SHEAR TRANSFER 1/2" = 1'-0 ��►..to mulm,0 l >=a .,1 lrft ROOF NOTES I. ROOF FRAMING SHALL BE: PRE -MFR TRUSSES ® 24" O.G. TYP. U.O.N. 2. ROOF PITCH SHALL BE: 4:12, TYP. 5. ROOF O.H. SHALL BE: 5'-0" ® ALL G.E. 5'-0" ® 4:12 PITCH 4. ROOF COVERING SHALL BE: COMP. 5HINGLE5 o/ 15# FELT 0/Y2" CDX OR OSB. w/ Sd'S ® 6", 12" O.G. 5. REQUIRED ATTIC, VENTILATION: 3188 / 500 = 10.65 SQ. FT. OF NET FREE AREA VENTILATION REQUIRED. WHOLE HOUSE FAN REQUIRED EXHAUST VENTINO: 4052OFM / 575 = 10.75 50. FT. OF NET FREE AREA VENTILATION REQUIRED. • 40% LOW VENTING: PROVIDE (15) 5?x22j" "VULCAN" EAVE VENTS ® .55 50. FT. EACH. TOTAL LOW VENTINS PROVIDED: 4.21 SQ. FT. OF NET FREE AREA • 60% HI OH VENTING (LOCATED MAX. 5' VERTICAL BELOW RIDGE): PROVIDE 85' CONT. RIDGE VENT ® 0.125 SQ. FT. PER FT. TOTAL HI OH VENTING PROVIDED: 10.5 50. FT. OF NET FREE AREA. TOTAL NFA VENTING PROVIDED: 14.51 50. FT. 6. ATTIC, MOUNTED F.A.U. PROVIDE SERVICE LIGHT w/ 5WITCH ® ACCE55 HOLE. PROVIDE IIOV SERVICE OUTLET ® UNIT. PROVIDE 24" WIDE CATWALK FROM AGGESS HOLE TO 50" SQ. x 50" HIGH CLEAR MAINTENANCE PLATFORM ® UNIT. SEOTION A-4 1/4" = I' -o" 0.75K DRAG 5'0516 STRAP ®-BM. V GSI6 STRAP ® BM. TO TOP PL. SPLICES - ATTIC, MTD. F.A.U., SEE NOTE 6 ROOF NOTES, SEE DETAIL�1 / MOTE: ROOF SHEATHING AND ATTIC GABLE END WALLS SHALL BE "TECH SHIELD" RADIANT -BARRIER OR EQ. rW%v%W - ivv i ": THE ENTIRE PERIMETER OF THE ROOF DIAPHRAGM SHALL BE ATTACHED TO THE BEAMS AND/OR TOP PL.'5 PER DETAILS 1/4 4 2/4, 7YP., U.O.N. ADDITIONAL FASTENERS MAY BE 0.81 K DRAG TRUSS V0516 STRAP ®P ffW IT # _ _ TO TOP PL. SPLICES F3U'T CUUN1YCEvEL0PNIENT sE, ViCES � " � FORREVIEVIED �0� CODE corIPLIANU DATE �1�!% V '! G �" 2 J Z j4 ROOF PLAN 1/8" = I'-0,. cu�u'J V RITAS 12,rol a a,1,7pjCt,, INC,_ Revision: Date: By: N W Mtn++ kn Icy U Mary � a� U U 0 e b W F+1 0 M 00 M W WoQ� � H � (D C) rO ° AA * No. C2 7/17 ®SGA MOON 2016 Date JANUARY 2016 Scale D`awnOSTROV5<IY Job 15-2126 Sheet 4 Of Sheets ELECTRICAL NOTE5: I. PROVIDE AN ADDITIONAL 20 AMP BRANCH CIRCUIT FOR EACH BATHROOM AND LAUNDRY. THESE CIRCUITS SHALL SERVE NO OTHER OUTLETS. 2. ALL 15 4 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN BEDROOMS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, 5UNROOM5, RECREATION ROOMS, HALLWAYS, CLOSETS OR SIMILAR ROOMS, SHALL BE INSTALLED WITH A COMBINATION ARG -FAULT CIRCUITS INTERRUPTERS. 5. PROVIDE (2) OR MORE 20 -AMP SMALL APPLIANCE BRANCH CIRCUITS EVENLY PROPORTIONED IN THE KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREA TO SERVE ALL WALL AND FLOOR OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS. 4. ALL 125 VOLT, SINGLE PHASE, 15 AND 20 AMP RECEPTACLES SHALL BE L15TED TAMPER RESISTANT RECEPTACLES. 5. FIXTURES, LAMP HOLDERS AND RECEPTACLES OUTLETS SHALL BE SECURELY SUPPORTED. A FIXTURE THAT WEIGHS MORE THAN 61b5 OR EXCEEDS 161n. IN ANY DIMENSION SHALL NOT BE SUPPORTED BY THE SCREW SHELL OF A LAMP HOLDER PER 2015 GEC, SECTION 410.15. (a). OUTLET BOXES SHALL NOT BE USED AS THE 50LE SUPPORT FOR CEILING FANS PER 2015 SECTION 314.2'1 (a 4 d). 6. ALL HARDWIRED DETECTORS SHALL BE INTERCONNECTED. -I. ALL GARAGE, LAUNDRY ROOM, AND UTILITY ROOM LIGHTING SHALL BE HIGH -EFFICACY AND CONTROLLED BY A MANUAL -ON OCCUPANCY SENSOR. VENTILATION REQUIREMENTSI I. KITCHEN VENTILATION: A. THE KITCHEN SHALL HAVE AN EXHAUST FAN W A MIN. VENTILATION RATE OF 100 CFM. B. THE NOISE RATING SHALL BE 5 SOME MAXIMUM. G. THE FAN SHALL BE DUCTED TO THE OUTSIDE w/ A MINIMUM 5"c7 SMOOTH DUCT (55' MAXIMUM RUN w/ (2) ELBOWS OR FITTINGS). 2. BATHROOM VENTILATION: A. EACH BATHROOM SHALL HAVE AN EXHAUST FAN w/ A MIN. VENTILATION RATE OF 50 CFM. B. THE N015E RATING SHALL BE 5 SONE MAXIMUM. G. THE FAN SHALL BE DUCTED TO THE OUTSIDE w/ A MINIMUM 4"(P SMOOTH DUCT 05' MAXIMUM RUN w/ (2) ELBOWS OR FITTINGS). D. BATHROOM EXHAUST FANS MUST BE CONTROLLED BY A HUMID15TAT CONTROL CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50 TO aO%. 2015 COB50 SECTION 4.506. 5. WHOLE - BUILDING \/ENTILATION: SEE GFIR FOR WHOLE BUILDING VENTILATION REGU I RED CFM. ONE BATHROOM FAN SHALL BE '10 CFM. MIN. w/ A MAXIMUM N015E RATING OF I SONE. THE SWITCH SHALL BE LABELED "VENTILATION CONTROL." COMPLY WITH CAUFORNL4 ELECTRICAL CODE -for wiring methods- secure conductors and conduit per all applicable requirements as required by the 2013 CEC for the specific method of wiring PATIO BBQ I� I I �I IN UPPER I HP/ wP/ CABINETS I I chOFI ' _—. _-, RGFI VERIFY LOCATION A/C UNIT 6FI 8 20 V. INSTA-HOT WATER ` MSTR. L - = J BATH k i i MSTR. BEDROOM KITCHEN DINING i SOF I I I GFI I ; � I I I � I � \ JOFI O \ 1-1 F-LEGTRI GAL 5`rM50L 5 I SINGLE POLE SWITCH - GLC. MTD. FIXT. GEILINO FAN w/ LIGHT KITCHEN LIGHTING SCHEDULE: N FLUORESCENT MTD. FIXT. 3 rl CLO. A B LUMINAIRE TYPE: HIGH EFFICACY: WATT5: QUANTITY: HIGH EFFICACY WATTS: OTHER WATTS: COMPACT FLUOR. YES 26 8 208 UNDER CABINET 5' FLUOR. TUBE YES 25 2 50 FLUORESCENT LIGHTING 2' FLUOR. TUBE YES 17 2 34 PENDANT NO 100 2 E _ ;J 200 DUPLEX REGEPT. FLUORESCENT TOTAL (A): 252 TOTAL (5):200 COMPLIES IF A >/= B YES X NO RECESSED CLO. FIXT. 0 SIGNAL PUSH BUTTON 220 VOLT OUTLET LED O COMPLY WITH CAUFORNL4 ELECTRICAL CODE -for wiring methods- secure conductors and conduit per all applicable requirements as required by the 2013 CEC for the specific method of wiring PATIO BBQ I� I I �I IN UPPER I HP/ wP/ CABINETS I I chOFI ' _—. _-, RGFI VERIFY LOCATION A/C UNIT 6FI 8 20 V. INSTA-HOT WATER ` MSTR. L - = J BATH k i i MSTR. BEDROOM KITCHEN DINING i SOF I I I GFI I ; � I I I � I � \ JOFI O \ 1-1 F-LEGTRI GAL 5`rM50L 5 I SINGLE POLE SWITCH - GLC. MTD. FIXT. GEILINO FAN w/ LIGHT THREE WAY SWITCH N FLUORESCENT MTD. FIXT. 3 rl CLO. tDIMMER D SWITCH NO, LED CLO. MTD. FIXT. i GEILINO FAN NO LIGHT �D3 /5 -AY SWITCH DIMMERW n RECESSED CLO. FIXT. H UNDER CABINET � CIS w � }—� FLUORESCENT LIGHTING $T TIMER SWITCH ELEG. BALLAST, C �•I AIR -TIGHT, IG RATED E _ ;J FLUORESCENT FIXTURE DUPLEX REGEPT. FLUORESCENT M•�y � a� RECESSED CLO. FIXT. 0 SIGNAL PUSH BUTTON 220 VOLT OUTLET LED O O C PUCK LIGHT DUPLEX SPLIT WIRED RECESSED CLO. FIXT. o -�- MINI RECESSED CLO. FIXT. PANEL BOARD QUAD. REGEPT. M }- WALL MTD. FIXTURE EP ELEC. DISCONNECT FLOOR OUTLET I--� FLUORESCENT ® 110 V. SMOKE DETECTOR a TV OUTLET WALL MTD. FIXTURE -�- TRACK FIXTURE � EXHAUST FAN PHONE OUTLET V1 0 Z -�- PENDANT LIGHT � WHOLE HOUSE VACUUM CONNECTION e TV/PHONE OUTLET � SCONCE FIXTURE G1" 1 I10v CARBON MONOXIDE VP SUITABLE FOR DAMP di ALARM w/ BATTERY LOCATION BACKUP E --I <� MINI SCONCE FIXTURE -}— FUEL GAS OUTLET MOTION -ACTIVATED_ SECURITY LIGHT _ r -. AUTOMATIC, OARAOE DOOR OPENER LISTED IN �- [� - ACCORDANCE w/ UL 525 * NO. C2 N� 83 w/ GFI OUTLET I. ALL LIGHTING FIXTURES SHALL BE ASSUMED INCANDESCENT U.O.N. AS LED OR FLUORESCENT. 2. ALL EXTERIOR LIGHTING FIXTURES SHALL BE "SUITABLE FOR DAMP LOCATIONS" COMPLY WITH CALIF01M ELECTRICAL CODE— AR77CLE 410-8 REQUIREMENTS FOR LIGHTING FIXTURES IN CLOTHES CLOSETS GFI OFI REAR COVERED - - - I L'NDRY FORGH I I WP/ I GFI qP I e. BEDROOM 5 I I I r� I IREF _ _ I /I 220 �. 6FI DI /I D 220 V. UGLs I OVENS L J 4052 CFM BELT -DRIVE WHOLE HOUSE FAN w/ R4.2 INSUL., w/ �A \/'ARIABLE SPEED RHEOSTAT. - 7 1-40� I I HALL CONFIRM co LOCATION qp I OWNERS LIVING ENTRY ` ROOM / ( VP BATH \ / ( U GFI II i Tr NP/ COVERED II ( GFI �'ORGH � C741 II I I I I I I I I II I I II 1 INA - - - BEDROOM 2 COMPLY WITH CALIFORNM ELECTRICAL CODE- ARTICLE 410.30& 314.27 (A&D) fixtures Lamp holders &receptacle Outlets shall be securely supported complying with these CEC Articles COMPLY WITH CALIFORNIA ELECTRICAL CODE- AR77CLE 110 REQUIREMENTS FOR ELECTRICAL EQUIPMENT INSTALLATIONS F-LEGTRI GAL FLAN 1/4" = 1'-0 Provide separate grounding conductor from main electric se ry structures 'Ce panel to remote and remote subpanels CEC Art. 250.32(D) OFI'li' NOTE: GARAGE RECEPTACLES TO BE +IS" A.F.F. I OF I GF I r 71 OARAOE I/ I -J T LTJ ELEG. SUB -PANEL. SEE GALGREEN RESIDENTIAL GFI MANDATORY MEASURES, _ 4.106.4.1 FOR ELEGTRIG VEHICLE CHAROINO REa'5. 541 200 AMP I ELECT. MAIN PANEL GFI The bathroom exhaust fan shall be controlled with humidistat control capable of adjustment between a relative humidity range of 50% to 80%. 2013 CGBC Section 4.506 Label, circuit breaker(s), disconnect(s), fuse(s),switch(es) and their accessories, to identify their location and or equipment PROVIDE SMOKE DETECTORS/A AS REQUIRED By 2013 CBC ARMS CRC SECTION R314 SECTION 907 AND 2013 AS PROVIDE CARBON MONOXIDE DETECTOR&4LARMS CRC SECTION R315 REQUIRED 8315 CBC SECTION 420.4 AND 2013 C COMPLY WITH CALIFORNIA ELECTRICAL CODE ARTICLE 250 REQUIREMENTS FOR GROUNDING AND BONDING PERMIT #_: --- -- - - --AtY7 0 2 / 3 BUTiE COUt\i?Y OEVELOP,AENTSi=i?'yffS E' D FOR COD IE 0 'kti P L! DATE__,//Z [IL¢ib _ BY�j U/ 7/4r� E�'i �'sl-D FO CODF- GO'lIR AKIN S+SoEygj �!Gp'lTA Revision: Date: rl By: O N rl NO, i n H � CIS w � � PLO C �•I h M•�y � a� T 1 U O C W o M O� I--� z V1 0 Z W � � O di E --I <� d- O r0 4-1 [� o AA * NO. C2 N� 83 REN. /17 C MOON RE51 DENCE Date JANUARY 2016 Scale Drawn OSTRO\/SK I Y Job I5-2126 Sheet Of Sheets 2 CL N IR rl r -I et rl O N rl M i SECTION R327.3 STANDARDS OF QUALITY R327.3.1 General. Building material, systems, assemblies and methods of construction used in this chapter shall be in accordance with Section R327.3. R327.3.2 Qualification by testing. Material and material assemblies tested in accordance with the requirements of Section 703A shall be accepted for use when the results and conditions of those tests are met. Product evaluation testing of material and material assemblies shall be approved or listed by the State Fire Marshal, or identified in a current report issued by an approved agency. R327.3.3 Approved agency. Product evaluation testing shall be performed by an approved agency as defined in Section 1702. The scope of accreditation for the approved agency shall include building product compliance with code. R327.3.4 Labeling. Material and material assemblies tested in accordance with the requirements of section R327.3 shall bear an identification label showing the fire test results. That identification label shall be issued by a testing and/or inspecting agency approved by the State Fire Marshal. 1. Identification mark of the approved testing and/or inspecting agency. 2. Contact and identification information of the manufacturer. 3. Model number or identification of the product or material. 4. Pre-test weathering specified in this chapter. 5. Compliance standard as described under Section R327.3.7. R327.3.5 Weathering and surface treatment protection. R327.3.5.1 General. Material and material assemblies tested in accordance with the requirements of Section 703A shall maintain their fire test performance under conditions of use when installed in accordance with the manufacturers instructions. R327.3.5.2 Weathering. Fire -retardant -treated wood and fire -retardant -treated wood shingles and shakes shall meet the fire test performance requirements of this chapter after being subjected to the weathering conditions contained in the following standards, as applicable to the materials and the conditions of use. R327.3.5.2.1 Fire -retardant -treated wood. Fire -retardant -treated wood shall be tested in accordance with ASTM D 2898, "Standard Practice for Accelerated Weathering of Fire -Retardant Treated Wood for Fire Testing (Method A)" and the requirements of Section 2303.2. R327.3.5.2.2 Fire -retardant -treated wood shingles and shakes. Fire -retardant -treated wood shingles and shakes shall be approved and listed by the State Fire Marshal in accordance with Section 208(c), Title 19 California Code of Regulations. R327.3.5.3 Surface treatment protection. The use of paints, coatings, stains, or other surface treatments are not an approved method of protection as required in this section. R327.3.6 Alternates for materials, design, tests and methods of construction. The enforcing agency is permitted to modify the provisions of this chapter for site-specific conditions in accordance with Section 1.11.2.4. When required by the enforcing agency for the purposes of granting modifications, afire protection plan shall be submitted in accordance with the California Fire Code, Chapter 49. R327.3.7 Standards of quality. The State Fire Marshal standards for exterior wildfire exposure protection listed below and as referenced in this chapter are located in the California Referenced Standards Code, Part 12 and Chapter 35 of this code. SFM Standard 12-7A-1, Exterior Wall Siding and Sheathing. A fire resistance test standard consisting of a 150 kW intensity direct flame exposure for a 10 minutes duration. SFM Standard 12-7A-2, Exterior Windows. A fire resistance test standard consisting of a 150 kW intensity direct flame exposure for a 8 minutes duration. SFM Standard 12-7A-3, Horizontal Projection Underside A fire resistance test standard consisting of a 300 kW intensity direct flame exposure for a 10 minute duration. SFM Standard 12-7A-4, Decking. A two-part test consisting of a heat release rate (Part A) deck assembly combustion test with an under deck exposure of 80kW intensity direct flame for a 3 minute duration, and a (Part B) sustained deck assembly combustion test consisting of a deck upper surface burning ember exposure with a 12 mph wind for 40 minutes using a 2.2 Ib (1 kg) burning "Class A" size 12" x 12" x 2.25" (300 mm x 300 mm x 57 mm) roof test brand. SFM Standard 12 -7A -4A, Decking Alternate Method A. A heat release rate deck assembly combustion test with an under deck exposure of 80 kW intensity direct flame for a 3 minute duration. SFM Standard 12-7A-5, Ignition -Resistant Material. A generic building material surface burning flame spread test standard consisting of an extended 30 minute ASTM E84 or UL 723 test method as is used for Fire -Retardant -Treated wood. SECTION R327.4 IGNITION RESISTANT CONSTRUCTION R327.4.1 General. The materials prescribed herein for ignition resistance shall conform to the requirements of this chapter. R327.4.2 Ignition -resistant material. Ignition -resistant material shall be determined in accordance with the test procedures set forth in SFM Standard 12-7A-5 "Ignition -Resistant Material" or in accordance with this section. R327.4.3 Alternative methods for determining Ignition -resistant material. Any one of the following shall be accepted as meeting the definition of ignition -resistant material: 1. Noncombustible material. Material that complies with the definition for noncombustible materials in Section 202 2. Fire -retardant -treated wood. Fire -retardant -treated wood identified for exterior use that complies with the requirements of Section 2303.2 of the California Building Code. 3. Fire -retardant -treated wood shingles and shakes. Fire -retardant -treated wood shingles and shakes, as defined in Section 1505.6 of the California Building Code and listed by State Fire Marshal for use as "Class B" roof covering, shall be accepted as an Ignition -resistant wall covering material when installed over solid sheathing. SECTION R327.5 ROOFING R327.5.1 General. Roofs shall comply with the requirements of Sections R327 and R902. Roofs shall have a roofing assembly installed in accordance with its listing and the manufacturer's installation instructions. R327.5.2 Roof coverings. Where the roof profile allows a space between the roof covering and roof decking, the spaces shall be constructed to prevent the intrusion of flames and embers, be firestopped with approved materials or have one layer of minimum 72 pound (32.4 kg) mineral -surfaced nonperforated cap sheet complying with ASTM D 3909 installed over the combustible decking. R327.5.3 Roof valleys. Where valley flashing is installed, the flashing shall be not less than 0.019 -inch (0.48 mm) No. 26 gage galvanized sheet corrosion -resistant metal installed over not less than one layer of minimum 72 -pound (32.4 kg) mineral -surfaced nonperforated cap sheet complying with ASTM D 3909, at least 36 -inch -wide (914mm) running the full length of the valley. R327.5.4 Roof gutters. Roof gutters shall be provided with the means to prevent the accumulation of leaves and debris in the gutter. SECTION R327.6 VENTS R327.6.1 General. Where provided, ventilation openings for enclosed attics, enclosed eave soffit spaces, enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters, and underfloor ventilation shall be in accordance with Section 1203 of the California Building Code and Sections R327.6.1 through R327.6.3 of this section to resist building ignition from the intrusion of burning embers and flame through the ventilation opening. R327.6.2 Requirements. Ventilation openings for enclosed attics, enclosed eave soffit spaces, enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters, and underfloor ventilation openings shall be fully covered with metal wire mesh, vents, other materials, or other devices that meet the following requirements: 1. The dimensions of the openings therein shall be a minimum of 1/16 inch (1.6 mm) and shall not exceed 1/8 inch (3.2 mm). 2. The materials used shall be noncombustible. Exception: Vents located under the roof covering, along the ridge of roofs, with the exposed surface of the vent covered by noncombustible wire mesh, may be of combustible materials. 3. The materials used shall be corrosion resistant. R327.6.3 Ventilation openings on the underside of eaves and cornices. Vents shall not be installed on the underside of eaves and cornices. Exceptions: 1. The enforcing agency may accept or approve special eave and cornice vents that resist the intrusion of flame and burning embers. 2. Vents complying with the requirements of Section R327.6.2 may be installed on the underside of eaves and cornices in accordance with either one of the following conditions: 2.1.The attic space being ventilated is fully protected by an automatic sprinkler system installed in accordance with Section 903.3.1.1 of the California Building Code or, 2.2.The exterior wall covering and exposed underside of the eave are of noncombustible material, or ignition -resistant -materials as determined in accordance with SFM Standard 12-7A-5 Ignition -Resistant Material and the vent is located more than 12 feet from the ground or walking surface of a deck, porch, patio, or similar surface. SECTION R327.7 EXTERIOR COVERING R327.7.1 Scope. The provisions of this section shall govern the materials and construction methods used to resist building ignition and/or safeguard against the intrusion of flames resulting from small ember and short-term direct flame contact exposure. R327.7.2 General. The following exterior covering materials and/or assemblies shall comply with this section: 1. Exterior wall covering material. 2. Exterior wall assembly. 3. Exterior exposed underside of roof eave overhangs, 4. Exterior exposed underside of roof eave soffits. 5. Exposed underside of exterior porch ceilings. 6. Exterior exposed underside of floor projections. 7. Exterior underfloor areas. Exceptions: 1.1.Exterior wall architectural trim, embellishments, fascias and gutters. 1.2. Roof or wall top cornice projections and similar assemblies. 1.3. Roof assembly projections over gable end walls. 1.4. Solid wood rafter tails and solid wood blocking installed between rafters having minimum dimension 2 inch (50.8 mm) nominal. 1.5.Deck walking surfaces shall comply with Section R327.9 only. R327.7.3 Exterior walls. The exterior wall covering or wall assembly shall comply with one of the following requirements: 1. Noncombustible material. 2. Ignition -Resistant material. 3. Heavy timber exterior wall assembly. 4. Log wall construction assembly. 5. Wall assemblies that meet the performance criteria in accordance with the test procedures for a 10 -minute direct flame contact exposure test set forth in SFM Standard 12-7A-1. Exception: Any of the following shall be deemed to meet the assembly performance criteria and intent of this section: 1.1.One layer of 5/8 -inch Type X gypsum sheathing applied behind the exterior covering or cladding on the exterior side of the framing. 1.2. The exterior portion of a 1 -hour fire resistive exterior wall assembly designed for exterior fire exposure including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual. R327.7.3.1 Extent of exterior wall covering. Exterior wall coverings shall extend from the top of the foundation to the roof, and terminate at 2 inch (50.8 mm) nominal solid wood blocking between rafters at all roof overhangs, or in the case of enclosed eaves, terminate at the enclosure. R327.7.4 Open roof eaves. The exposed roof deck on the underside of unenclosed roof eaves shall consist of one of the following: 1. Noncombustible material. 2. Ignition -Resistant material. 3. One layer of 5/8 -inch Type X gypsum sheathing applied behind an exterior covering on the underside exterior of the roof deck. 4. The exterior portion of a 1 -hour fire resistive exterior wall assembly applied to the underside of the roof deck designed for exterior fire exposure including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual. Exceptions: The following materials do not require protection: 1.1. Solid wood rafter tails on the exposed underside of open roof eaves having a minimum nominal dimension of 2 inch (50.8 mm). 1.2. Solid wood blocking installed between rafter tails on the exposed underside of open roof eaves having a minimum nominal dimension of 2 inch (50.8mm). 1.3. Gable end overhangs and roof assembly projections beyond an exterior wall other than at the lower end of the rafter tails. 1.4. Fascia and other architectural trim boards. R327.7.5 Enclosed roof eaves and roof eave soffits. The exposed underside of enclosed roof eaves having either a boxed -in roof eave soffit with a horizontal underside, or sloping rafter tails with an exterior covering applied to the underside of the rafter tails, shall be protected by one of the following: 1. Noncombustible material. 2. Ignition -Resistant material. 3. One layer of 5/8 -inch Type X gypsum sheathing applied behind an exterior covering on the underside of the rafter tails or soffit. 4. The exterior portion of a 1 -hour fire resistive exterior wall assembly applied to the underside of the rafter tails or soffit including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual. 5. Boxed -in roof eave soffit assemblies with a horizontal underside that meet the performance criteria in accordance with the test procedures set forth in SFM Standard 12-7A-3. Exceptions: The following materials do not require protection: 1.1.Gable end overhangs and roof assembly projections beyond an exterior wall other than at the lower end of the rafter tails. 1.2. Fascia and other architectural trim boards. R327.7.6 Exterior porch ceilings. The exposed underside of exterior porch ceilings shall be protected by one of the following: 1. Noncombustible material. 2. Ignition -Resistant material. 3. One layer of 5/8 -inch Type X gypsum sheathing applied behind the exterior covering on the underside of the ceiling. 4. The exterior portion of a 1 -hour fire resistive exterior wall assembly applied to the underside of the ceiling assembly including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual. 5. Porch ceiling assemblies with a horizontal underside that meet the performance criteria in accordance with the test procedures set forth in SFM Standard 12-7A-3. Exception: Architectural trim boards. R327.7.7 Floor projections. The exposed underside of a cantilevered floor projection where a floor assembly extends over an exterior wall shall be protected by one of the following: 1. Noncombustible material. 2. Ignition -Resistant material. 3. One layer of 5/8 -inch Type X gypsum sheathing applied behind an exterior covering on the underside of the floor projection. 4. The exterior portion of a 1 -hour fire resistive exterior wall assembly applied to the underside of the floor projection including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual. 5. The underside of a floor projection assembly that meet the performance criteria in accordance with the test procedures set forth in SFM Standard 12-7A-3. Exception: Architectural trim boards. R327.7.8 Underfloor protection. The underfloor area of elevated or overhanging buildings shall be enclosed to grade in accordance with the requirements of this chapter or the underside of the exposed underfloor shall consist of one of the following: 1. Noncombustible material. 2. Ignition -Resistant material. 3. One layer of 5/8 -inch Type X gypsum sheathing applied behind an exterior covering on the underside of the floor projection. 4. The exterior portion of a 1 -hour fire resistive exterior wall assembly applied to the underside of the floor including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual. 5. The underside of a floor assembly that meets the performance criteria in accordance with the test procedures set forth in SFM Standard 12-7A-3. Exception: Heavy -timber structural columns and beams do not require protection. R327.7.8 Underside of appendages. When required by the enforcing agency the underside of overhanging appendages shall be enclosed to grade in accordance with the requirements of this chapter or the underside of the exposed underfloor shall consist of one of the following: 1. Noncombustible material. 2. Ignition -Resistant material. 3. One layer of 5/8 -inch Type X gypsum sheathing applied behind an exterior covering on the underside of the floor projection. 4. The exterior portion of a 1 -hour fire resistive exterior wall assembly applied to the underside of the floor including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual. 5. The underside of a floor assembly that meets the performance criteria in accordance with the test procedures set forth in SFM Standard 12-7A-3. Exception: Heaw-timber structural columns and beams do not reauire protection. SECTION 327.8 EXTERIOR WINDOWS AND DOORS R327.8.1 General. R327.8.2 Exterior glazing. The following exterior glazing materials and/or assemblies shall comply with this section: 1. Exterior window. 2. Exterior glazed doors. 3. Glazed openings within exterior doors. 4. Glazed openings within exterior garage door. 5. Exterior structural glass veneer. R327.8.2.1 Exterior windows and exterior glazed door assembly requirements. Exterior windows and exterior glazed door assemblies shall comply with one of the following requirements: 1. Be constructed of multiple glazing with a minimum of one tempered pane meeting the requirements of Section 2406 Safety Glazing, or 2. Be constructed of glass block units, or 3. Have a fire -resistance rating of not less than 20 minutes when tested according to NFPA 257, or 4. Be tested to meet the performance requirements of SFM Standard 12-7A-2. R327.8.2.2 Structural glass veneer. The wall assembly behind structural glass veneer shall comply with section R327.7.3. R327.8.3 Exterior doors. Exterior doors shall comply with one of the following: 1. The exterior surface or cladding shall be of noncombustible or Ignition -resistant material, or 2. Shall be constructed of solid core wood that comply with the following requirements: 2.1.Stiles and rails shall not be less than 1 3/8 inches thick 2.2.Raised panel shall not be less than 1 1/4 inches thick, except for the exterior perimeter of the raised panel that may taper to a tongue not less than 3/8 inch thick. 3. Shall have a fire -resistance rating of not less than 20 minutes when tested according to NFPA 252. 4. Shall be tested to meet the performance requirements of SFM Standard 12-7A-1. R327.8.3.1 Exterior door glazing. Glazing in exterior doors shall comply with Section 708A.2.1. SECTION R327.9 DECKING R327.9.1 General. The walking surface material of decks, porches, balconies and stairs shall comply with the requirements of this section. R327.9.2 Where required. The walking surface material of decks, porches, balconies and stairs shall comply with the requirements of this section when any portion of such surface is within 10 feet (3048 mm) of the building. R327.9.3 Decking surfaces. The walking surface material of decks, porches, balconies and stairs shall be constructed with one of the following materials: 1. Ignition -resistant material that complies with the performance requirement of both SFM Standard 12-7A-4 and SFM Standard 12-7A-5. 2. Exterior fire retardant treated wood. 3. Noncombustible material. 4. Any material that complies with the performance requirements of SFM Standard 12 -7A -4A when attached exterior wall covering is also either noncombustible or ignition -resistant material. Exception: Wall material may be of any material that otherwise complies with this chapter when the decking surface material complies with the performance requirement ASTM E 84 with a Class B flame spread rating. SECTION R327.10 ACCESSORY STRUCTURES R327.10.1 General. Accessory and miscellaneous structures, other than buildings covered by Section 701A.3, which pose a significant exterior exposure hazard to applicable buildings during wildfires shall be constructed to conform to the ignition resistance requirements of this section. R327.10.2 Applicability. The provisions of this section shall apply to trellises, arbors, patio covers, carports, gazebos, and similar structures of an accessory or miscellaneous character. Exceptions: 1. Decks shall comply with the requirements of Section 709A. 2. Awnings and canopies shall comply with the requirements of Section 3105. R327.10.3 Where required. Accessory structures shall comply with the requirements of this section. R327.10.3.1 Attached accessory structures shall comply with the requirements of this section. R327.10.3.2 When required by the enforcing agency, detached accessory structures within 50 feet of an applicable building shall comply with the requirements of this section. R327.10.4. Requirements. When required by the enforcing agency accessory structures shall be constructed of noncombustible or ignition -resistant materials. BUTTE COUNTY CE'vEL0PMENT SERVICES CO E C' 'IDL IP;N DATE. 3/1 °9 �I /� EViETED EO; co E CQ:,IPLIA110E mt� ": 2 5 R" 115 Revision: Date: By: N n u7 H � oA W � 0 N � o C lij Fh��1l UbA U °u hal •°d W C Wo rx 00 M W W H O AACA%�, * No. C 83 REN 7/17 DL D iRFACE I Date 2014 Scale Drawn Job Sheet wul Of Sheets TITLE 24 MANDATORY MEASURES BU I LD I NC ENVELOPE MEASURES 1. DOORS AND WINDOWS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SHALL BE MANUFACTURED TO LIMIT AIR LEAKAGE. 2. FENESTRATION PRODUCTS (EXCEPT FIELD -FABRICATED WINDOWS) SHALL HAVE A LABEL LISTING THE CERTIFIED U -FACTOR, CERTIFIED SOLAR HEAT GAIN COEFFICIENT (SHOC), AND INFILTRATION THAT MEETS THE REQUIREMENTS OF §IO-III(o). 3. EXTERIOR DOORS AND WINDOWS SHALL BE WEATHER-STRIPPED; ALL JOINTS AND PENETRATIONS CAULKED AND SEALED. 4. INSULATION SPECIFIED OR INSTALLED SHALL MEET STANDARDS FOR INSULATING MATERIAL. INDICATE TYPE AND INCLUDE ON GF -6R FORM. 5. THE THERMAL EMITTANGE AND SOLAR REFLECTANCE VALUES OF THE COOL ROOFING MATERIAL MEETS THE REQUIREMENTS OF §I10.6(l) WHEN THE INSTALLATION OF A COOL ROOF 15 SPECIFIED ON THE GF -IR FORM 6. A RADIANT BARRIER SHALL HAVE AN EMITTANGE OF 0.05 OR LE55 WHEN THE INSTALLATION OF A RADIANT BARRIER 15 SPECIFIED ON THE CFIR. 7. LOOSE FILL INSULATION SHALL CONFORM WITH MANUFACTURER'S INSTALLED DESIGN LABELED R -VALUE FIREPLACES DECORATIVE GAS APPLIANCES AND GAS LOC MEASURES: I. MASONRY OR FACTORY -BUILT FIREPLACES SHALL HAVE A CLOSABLE METAL OR GLASS DOOR COVERING THE ENTIRE OPENING OF THE FIREBOX. 2. MASONRY OR FACTORY -BUILT FIREPLACES SHALL HAVE A COMBUSTION OUT51ME AIR INTAKE, WHICH 15 AT LEAST SIX SQUARE INCHES IN AREA AND 15 EQUIPPED W A READILY ACCESSIBLE, OPERABLE, AND TIGHT -FITTING DAMPER AND OR A COMBUSTION -AIR CONTROL DEVICE. 3. MASONRY OR FACTORY -BUILT FIREPLACES HAVE A FLUE DAMPER WITH A READILY ACCESSIBLE CONTROL. 4. CONTINUOUS BURNING PILOT LIGHTS AND THE USE OF INDOOR AIR FOR COOLING A FIREBOX JACKET, WHEN THAT INDOOR AIR IS VENTED TO THE OUTSIDE OF THE BUILDING, ARE PROHIBITED. SPACE CONDITIONING WATER HEATING AND PLUMBING SYSTEM MEASURES I. HVAC EQUIPMENT, WATER HEATERS, SHOWERHEAD5, FAUCETS AND ALL OTHER REGULATED APPLIANCES SHALL BE CERTIFIED BY THE ENERGY COMMISSION. 2. WATER HEATER RECIRCULATION LOOPS 5ERVIN6 MULTIPLE UNITS MEET THE AIR RELEASE VALVE, BACKFLOW PREVENTION, PUMP ISOLATION VALVE, AND RECIRCULATION LOOP CONNECTION REQUIREMENTS. 3. CONTINUOUSLY BURNING PILOT LIGHTS ARE PROHIBITED FOR NATURAL OAS: FAN -TYPE CENTRAL FURNACES, HOUSEHOLD GOOKIN6 APPLIANCES (APPLIANCES w/OUT AN ELECTRICAL SUPPLY VOLTAGE CONNECTION w/ PILOT LIGHTS THAT CONSUME LESS THAN 150 Btu/hr ARE EXEMPT), AND POOL AND SPA HEATERS. 4. HEATING AND/OR COOLING LOADS SHALL BE CALCULATED IN ACCORDANCE w/ ASHRAE, SMAGNA OR ALGA. 5. INSTALLED AIR CONDITIONER AND HEAT PUMP OUTDOOR CONDENSING UNITS SHALL HAVE A CLEARANCE OF AT LEAST V FROM THE OUTLET OF ANY DRYER VENT. 6. HEATING 5Y5TEM5 SHALL BE EQUIPPED w/ THERMOSTATS THAT MEET THE SETBACK REQUIREMENTS OF SECTION 110.2(0). 1. STORAGE GAS WATER HEATERS RATED w/ AN ENERGY FACTOR NO GREATER THAN THE FEDERAL MINIMAL STANDARD SHALL BE EXTERNALLY WRAPPED W/ INSULATION HAVING AN INSTALLED THERMAL RESISTANCE OF R-12 OR GREATER. 6. UNFIRED HOT WATER TANKS, SUCH AS 5TORAOE TANKS AND BACKUP 5TORAOE TANKS FOR SOLAR WATER -HEATING SYSTEMS, HAVE R-12 EXTERNAL INSULATION OR R-16 INTERNAL INSULATION R -VALUE 15 INDICATED ON THE EXTERIOR OF THE TANK. el. FIRST 5 FT. OF HOT AND GOLD WATER PIPES CLOSEST TO WATER HEATER TANK, ALL PIPING WITH A NOMINAL DIAMETER OF J" OR LARGER, ALL PIPING ASSOCIATED w/ A DOMESTIC HOT WATER RECIRCULATION SYSTEM REOARDLES5 OF THE PIPE DIAMETER, PIPING FROM THE HEATING SOURCE TO STORAGE TANKS, PIPING BURIED BELOW GRADE, AND ALL HOT WATER PIPES FROM, THE HEATING SOURCE TO KITCHEN FIXTURES MUST BE INSULATED ACCORDING TO THE REQUIREMENTS TABLE 120.3-A. 10. ALL DOMESTIC HOT WATER PIPES THAT ARE BURIED BELOW GRADE MUST BE INSTALLED IN A WATER PROOF AND NON -CRUSHABLE CASINO OR SLEEVE THAT ALLOWS FOR INSTALLATION, REMOVAL, AND REPLACEMENT OF THE ENCLOSED PIPE AND INSULATION. II. PIPE FOR COOLING SYSTEM LINES SHALL BE INSULATED A5 SPECIFIED IN §150.0(J)2A. PIPING INSULATION FOR STEAM AND HYDRONIG HEATING SYSTEMS OR HOT WATER SYSTEMS WITH PRE55URE >I5 pslg SHALL MEET THE REQUIREMENTS IN TABLE 120.3-A. 12. INSULATION SHALL BE PROTECTED FROM DAMAGE, INCLUDINO THAT DUE To 5UNLIGH ,MOISTURE EQUIPMENT MAINTENANCE, AND WIND. 13. INSULATION EXPOSED TO WEATHER SHALL EITHER BE RATED FOR OUTDOOR USE OR INSTALLED WITH A COVER SUITABLE FOR OUTDOOR SERVICE. 14. INSULATION FOR CHILLED WATER PIPING AND REFRIGERANT SUCTION LINES SHALL INCLUDE A VAPOR RETARDANT OR BE ENCLOSED ENTIRELY IN CONDITIONED SPACE. 15. SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE: A 120V ELECTRICAL RECEPTACLE WITHIN 3' OF THE WATER HEATER; A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH A 5TRAI&HT PIPE BETWEEN THE OUTSIDE TERMINATION AND THE SPACE WHERE THE WATER HEATER 15 INSTALLED; A CONDENSATE DRAIN THAT 15 NOT MORE THAT 2" HIGHER THAT THE BASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE; AND A OAS SUPPLY LINE WITH A CAPACITY OF AT LEAST 200,000 BTU/HR. 16. RECIRCULATING LOOPS 5ERVIN6 MULTIPLE DWELLING UNITS SHALL MEET THE REQUIREMENTS OF §110.3(c)5 17. SOLAR WATER -HEATING SYSTEMS AND COLLECTORS SHALL BE CERTIFIED AND RATED BY THE SOLAR RATIN05 AND CERTIFICATION CORPORATION OR BY A TESTING AGENCY APPROVED BY THE EXECUTIVE DIRECTOR. DUCTS AND FAN MEASURES: I. ALL AIR -DISTRIBUTION SYSTEM DUCTS AND PLENUMS INSTALLED, ARE SEALED AND INSULATED TO MEET THE REQUIREMENTS OF CMG SECTIONS 601, 602, 603, 604, 605 AND AN51/5MAGNA-006-2006 HVAC, DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE 3rd ADDITION. SUPPLY -AIR AND RETURN -AIR DUCTS AND PLENUMS ARE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-6.0 OR ENCLOSED ENTIRELY IN CONDITIONED SPACE AS CONFIRMED THROUGH FIELD VERIFICATION AND DIAON05TIC TESTING. CONNECTIONS OF METALS DUCTS AND INNER GORE OF FLEXIBLE DUCTS ARE MECHANICALLY FASTENED. OPENINGS SHALL BE SEALED w/ MASTIC, TAPE OR OTHER DUCT-01_05URE SYSTEM THAT MEETS THE APPLICABLE REQUIREMENTS OF UL -161, UL 151A, OR UL 1515 OR AEROSOL SEALANT THAT MEETS THE REQUIREMENTS OF UL -723. IF MASTIC OR TAPE 15 USED TO SEAL OPENINGS GREATER THAN Y4 INCH, THE COMBINATION OF MASTIC AND EITHER MESH OR TAPE SHALL BE USED. 2. BUILDING CAVITIES, SUPPORT PLATFORMS FOR AIR HANDLER5, AND PLENUMS DEFINED OR CONSTRUCTED w/ MATERIALS OTHER THAN SEALED SHEET METAL, DUCT BOARD OR FLEXIBLE DUCT SHALL NOT BE USED FOR CONVEYING CONDITIONED AIR. BUILDING CAVITIES AND SUPPORT PLATFORMS MAY CONTAIN DUCTS. DUCTS INSTALLED IN CAVITIES AND SUPPORT PLATFORMS SHALL NOT BE COMPRESSED TO CAUSE REDUCTIONS IN THE CRO55-5ECTIONAL AREA OF THE DUCTS. 3. FACTOR FABRICATED DUCT SYSTEMS SHALL COMPLY w/ SPECIFIED FOR DUCT CONSTRUCTION, AND CLOSURES; JOINTS AND SEAMS OF DUCT SYSTEMS AND THEIR COMPONENTS SHALL NOT BE SEALED w/ CLOTH BACK RUBBER ADHESIVE DUCT TAPES UNLE55 SUCH TAPE IS USED IN COMBINATION w/ MASTIC AND DRAW BONDS. 4. FIELD FABRICATED DUCT SYSTEMS SHALL COMPLY w/ REQUIREMENTS FOR DUCT CONSTRUCTION, CONNECTIONS, AND CLOSURES, AND OTHER REQUIREMENTS SPECIFIED FOR DUCT CONSTRUCTION DUCT INSULATION R -VALUE RATING; DUCT INSULATION THICKNESS; AND DUCT LABELING. 5. ALL FAN SYSTEMS THAT EXCHANGE AIR BETWEEN ORIGINAL CONDITIONED SPACE AND THE OUTSIDE SHALL HAVE BACK DRAFT OR AUTOMATIC DAMPERS. 6. GRAVITY VENTILATING SYSTEMS 5ERVIN6 CONDITIONED SPACE SHALL HAVE EITHER AUTOMATIG OR READILY AGG SSIB E, MANUALLYLY OPERATED DAMPERS EXCEPT COMBUSTION INLET AND OUTLET AIR OPENIN05 AND ELEVATOR SHAFT VENTS. -1. INSULATION SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT DUE TO SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE, AND WIND, BUT NOT LIMITED TO THE FOLLOWING; INSULATION EXPOSED TO WEATHER SHALL BE SUITABLE FOR OUTDOOR SERVICE. CELLULAR FOAM INSULATION SHALL BE PROTECTED AS ABOVE OR PAINTED WITH A COATING THAT 15 WATER RETARDANT AND PROVIDES SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEGRADATION OF THE MATERIAL. 6. FLEXIBLE DUCT5 CANNOT HAVE POROUS INNER GORES. DUCTS SHA BE SEALED AND DUCT LEAKAGE TESTED A5 a. WHEN SPACE CONDITIONING SYSTEMS USE FORGED AIR SYSTEMS TO SUPPLY CONDITIONED AIR TO AN OCCUPIABLE SPACE, THE D LL , CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC D TESTING, IN ACCORDANCE WITH REFERENCE RESIDENTIAL APPENDIX RA5. 10. MECHANICAL SYSTEMS THAT SUPPLY AIR TO AN OCCUPIABLE SPACE THROUGH DUCTWORK EXOEEDIN6 10' IN LENGTH AND THROUGH A THERMAL GONDITIONINO COMPONENT, EXCEPT EVAPORATIVE COOLERS, SHALL BE PROVIDED w/ AIR FILTERS DEVICES THAT MEET THE REQUIREMENTS OF §150.0(m)12. 11. SPACE CONDITIONIN& SYSTEMS THAT UTILIZE FORGED AIR DUCTS TO SUPPLY COOLING TO AN OCCUPIABLE SPACE SHALL HAVE A HOLE FOR THE PLACEMENT OF A STATIC PRESSURE PROBE (HSPP), OR A PERMANENTLY INSTALLED STATIC PRESSURE PROBE (PSPP) IN THE SUPPLY PLENUM. THE SPACE CONDITIONING SYSTEM MUST ALSO DEMONSTRATE AIRFLOW :5 0.56 I^/CFM AS CONFIRMED BY FIELD VERIFICATION AND DIAONOSTIC TESTING, IN ACCORDANCE w/ REFERENCE RESIDENTIAL APPENDIX RA5. 12. ZONALLY CONTROLLED CENTRAL FORGED AIR COOLINO SYSTEMS SHALL BE CAPABLE OF SIMULTANEOUSLY DELIVERING, IN EVERY ZONAL CONTROL MODE, AND AIRFLOW FROM THE DWELLING, THROUGH AIR HANDLER FAN AND DELIVERED TO THE DWELLING, OF 5 350 GFM PER TON OF NOMINAL COOLING CAPACITY, AND OPERATING AT AN AIR -HANDLING UNIT FAN EFFICACY OF 50.56 W/GFM AS CONFIRMED BY FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH REFERENCE APPENDIX RA5. 13. ALL DWELLING UNITS SHALL MEET THE REQUIREMENTS OF ASHRAE STANDARD 62.2. NEITHER WINDOW OPERATION NOR CONTINUOUS OPERATION OF CENTRAL FORGED AIR SYSTEM AIR HANDLERS USED IN CENTRAL FAN INTEGRATED VENTILATION SYSTEMS ARE PERMISSIBLE METHOD OF PROVIDING THE WHOLE BUILDING VENTILATION. 14. WHOLE BUILDING VENTILATION AIRFLOW SHALL BE CONFIRMED THROUGH FIELD VERIFICATION AND DIAON05TIC TESTING, IN ACCORDANCE w/ REFERENCE RESIDENTIAL APPENDIX RA3.YAH RESIDENTIAL LIGHTING MEASURES: I. INSTALLED LUMINARIES SHALL BE CLA551FIED AS HIGH -EFFICACY OR LOW -EFFICACY FOR COMPLIANCE WITH §I50.0(k) IN ACCORDANCE WITH TABLE 150.0-A OR TABLE 150.05, AS APPLICABLE. 2. WHEN A HIGH EFFICACY AND LOW EFFICACY LIGHTING SYSTEM ARE COMBINED IN A SINGLE LUMINAIRE, EACH SYSTEM SHALL SEPARATELY COMPLY WITH THE APPLICABLE PROVISIONS OF §I50.O(Fv. 3. THE WATTAGE AND CLASSIFICATION OF PERMANENTLY INSTALLED LUMINARIES IN RESIDENTIAL KITCHENS SHALL BE DETERMINED IN ACCORDANCE w/ §I50.0(c). IN RESIDENTIAL KITCHENS, THE WATTAGE OF ELECTRICAL BOXES FINISHED W A BLANK COVER OR WHERE NO ELECTRICAL EQUIPMENT HAS BEEN INSTALLED, AND WHERE THE ELECTRICAL BOX CAN BE USED FOR A LUMINAIRE OR A SURFACE MOUNTED GEILIN6 FAN, SHALL BE CALCULATED AS 160 WATTS OR LOW EFFICACY LIGHT IN6 PER ELECTRICAL BOX. 4. BALLA5T5 FOR FLUORESCENT LAMPS RATED 13 WATTS OR GREATER SHALL BE ELECTRONIC AND SHALL HAVE AN OUTPUT FREQUENCY NO LE55 THAN 20 kHz. 5. PERMANENTLY INSTALLED NIGHT LIGHTS AND NIGHT INTEGRAL TO INSTALLED LUMINAIRE OR EXHAUST FAN SHALL BE RATED TO CONSUME NO MORE THAN FIVE WATTS OF POWER PER LUMINAIRE OR EXHAUST FAN AS DETERMINED IN ACCORDANCE w/ §130.0(c). N16HT LI&HT5 DO NOT NEED TO BE CONTROLLED BY VAGANGY SENSORS. 6. LIGHTING INTEGRAL TO EXHAUST FANS, IN ROOMS OTHER THAN KITCHENS, SHALL MEET THE APPLICABLE REQUIREMENTS OF §I50.0(k) 7. HIGH EFFICACY LUMINAIRES MUST BE SWITCHED SEPARATELY FROM LOW EFFICACY LUMINAIRES. 5. EXHAUST FANS SHALL BE 5WITGHED SEPARATELY FROM LIGHTING SYSTEMS. Q. LUMINAIRES SHALL BE SWITCHED w/ READILY ACCESSIBLE CONTROLS THAT PERMIT THE LIMINAIRE5 TO BE MANUALLY SWITCHED ON AND OFF. 10. NO CONTROL SHALL BYPASS A DIMMER OR VACANCY SENSOR FUNCTION IF THE CONTROL IN INSTALLED TO COMPLY w/ §I50.0(k). II. LIGHTING CONTROLS COMPLY w/ APPLICABLE REQUIREMENTS OF §IIO.Q. 12. AN ENERGY MANAGEMENT CONTROL SYSTEM (EMG5) MAY BE USED TO COMPLY w/ DIMMER REQUIREMENTS IF; IT FUNCTIONS AS A VACANCY SENSOR. 13. A MULTI50ENE PR06RAMMABLE CONTROLLER MAY BE USED w/ DIMMER REQUIREMENTS IF IT PROVIDES THE FUNCTIONALITY OF A DIMMER. 14. A MINIMUM OF 50 PERCENT OF THE TOTAL RATED WATTAGE OF PERMANENTLY INSTALLED LIGHTING IN KITCHENS SHALL BE HIGH EFFICACY. 15. KITCHEN LIGHTING INCLUDES ALL PERMANENTLY INSTALLED LIGHTING IN THE KITCHEN EXCEPT INTERNAL LIGHTING IN CABINETS THAT ILLUMINATE ONLY THE INSIDE OF CABINETS. LIGHTING IN AREAS ADJACENT TO THE KITCHEN, INGLUDIN6 BUT NOT LIMITED TO DINING AND NOOK AREAS, ARE CONSIDERED KITCHEN LIGHTING IF THEY ARE NOT SEPARATELY 5WITGHED FROM THE KITCHEN LIGHTING. 16. PERMANENTLY INSTALLED LIGHTING THAT 15 INTERNAL TO CABINETS SHALL USE NO MORE THAN 20 WATT5 OF POWER PER LINEAR FOOT OF ILLUMINATED CABINET. 17. A MINIMUM OF ONE HIGH EFFICACY LUMINAIRE SHALL BE INSTALLED IN EACH BATHROOM; AND ALL OTHER LIGHTING INSTALLED IN EACH BATHROOM SHALL BE HIGH EFFICACY OR CONTROLLED BY VACANCY SENSOR. lb. PERMANENTLY INSTALLED LUMINAIRES IN ATTACHED AND DETACHED GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS SHALL BE HIGH EFFICACY, AND CONTROLLED BY VACANCY SENSORS. la. PERMANENTLY INSTALLED LUMINAIRES LOCATED IN ROOMS OR AREAS OTHER THAN KITCHENS, BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS SHALL BE HIGH EFFICACY LUMINAIRES, OR CONTROLLED BY EITHER DIMMER5 OR VACANCY SENSORS. 20. LUMINAIRES RECESSED INTO INSULATED CEILIN55 SHALL BE L15TED FOR ZERO CLEARANCE INSULATION CONTACT (IC) BY UNDERWRITTEN LABORATORIES OR OTHER NATIONALLY RECOGNIZED TE5TING/RATIN6 LABORATORY; AND HAVE A LABEL THAT CERTIFIES THE LUMINAIRE IS AIRTIGHT WIT AIR LEAKAGE LE55 THEN 2.0017M AT '75 PA50AL5 WHEN TESTED IN ACCORDANCE WITH ASTM E263; AND BE SEALED WITH A 6A5KET OR CAULK BETWEEN THE LUMINAIRE HOUSING AND GEILIN6. FOR RECESSED COMPACT FLUORESCENT LUMINAIRES w/ BALLASTS TO QUALIFY AS H16H EFFICACY. 21. LUMINAIRES PROVIDING OUTDOOR LIGHTING, INGLUDIN6 LIOHTINO FOR PRIVATE PATIOS IN LOW-RISE RESIDENTIAL BUILDINGS WITH FOUR OR MORE DWELLING UNITS, ENTRANCES, BALCONIES, AND PORCHES, WHICH ARE PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING OR TO OTHER BUILDIN65 ON THE SAME LOT SHALL BE HIGH EFFICACY. EXCEPTION I: PERMANENTLY INSTALLED OUTDOOR LOW EFFICACY LUMINAIRES SHALL BE ALLOWED PROVIDED THAT THEY ARE CONTROLLED BY A MANUAL-OWOFF SWITCH, A MOTION SENSOR NOT HAVING AN OVERRIDE OR BYPASS 5WITGH THAT DISABLES THE MOTION SENSOR, AND ONE OF THE FOLLOWING CONTROLS: A PHOTOGONTROL NOT HAVING AN OVERRIDE OR BYPASS 5WITGH THAT DISABLES THE PHOTOGONTROL; OR AN ASTRONOMICAL TIME CLOCK NOT HAVING AN OVERRIDE OR BYPA55 5WITGH THAT DISABLES THE ASTRONOMICAL TIME CLOCK; OR AN ENERGY MANAGEMENT CONTROL 5Y5TEM (EMG5) NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT ALLOWS THE LUMINAIRE TO BE ALWAYS ON. EXCEPTION 2: OUTDOOR LUMINAIRES USED TO COMPLY WITH EXCEPTIONAL MAY BE CONTROLLED BY A TEMPORARY OVERRIDE 5WITGH WHICH BYPA55ES THE MOTION 5EN5IN& FUNCTION PROVIDED THAT THE MOTION SENSOR 15 AUTOMATICALLY REACTIVATED WITHIN 51X HOURS. 22. INTERNALLY ILLUMINATED ADDRESS 51GN5 SHALL COMPLY WITH SECTION 140.6; OR SHALL CONSUME NO MORE THAN 5 WATTS OF POWER. 23. LIGHTING FOR PARKING LOTS AND CARPORTS WITH A TOTAL OF 5 OR MORE VEHICLES PER SITE SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS IN SECTIONS 130, 132, 134, AND 14-7. LIGHTING FOR PARKING GARAOE5 FOR 6 OR MORE VEHICLES SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF SECTIONS 130, 131, 134, AND 146. 24. PERMANENTLY INSTALLED LIOHTINO IN THE ENCLOSED, NON DWELLING SPACES OF LOW-R15E RESIDENTIAL BUILDING WITH 4 OR MORE DWELLING UNITS SHALL BE HIGH EFFICACY LUMINAIRES. EXCEPTION: PERMANENTLY INSTALLED LOW EFFICACY LUMINAIRES SHALL BE ALLOWED PROVIDED THAT THEY ARE CONTROLLED BY AN OCCUPANT 5EN5OR(S) CERTIFIED TO COMPLY WITH THE APPLICABLE REQUIREMENTS. SOLAR READY BU I LD I NGS: I. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A MINIMUM BUSBAR RATIN& OF 200 AMPS. 2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR ELECTRIC INSTALLATION. THE RESERVED SPACE SHALL BE: POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION, PERMANENTLY MARKED AS "FOR FUTURE 50LAR ELECTRIC". 2013 CALGreen Residential Mandatory Measures Planning and Design 4.106.2 - Storm Water Drainage and Retention - Projects which disturb less than one acre of soil and are not part of a larger common plan of development shall manage storm water drainage during construction. 4.106.3 - Grading and Paving - Construction plans shall indicate how the site grading and drainage system will manage all surface water flows to keep water from entering building. Exception: Additions or alterations not altering the drainage path. 4.106.4.1- Electric Vehicle (EV) charging - For new constructed dwelling units, install a listed raceway to accommodate a dedicated 208/240 -volt branch circuit. The raceway shall not be less than trade size 1(nominal 1 -inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40 -ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. The service panel or subpanel circuit directory shall identify the overcurrent protective device spaces(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". Energy Efficiency 4.201.1-5.201.1- Low-rise residential (Section 4.201.1) and high-rise reside ntia t/hoteI/otof (Section .201.1) building shall meet or exceed the minimum standards design required by the California Energy Standards. Standards for residential buildings do not require compliance with levels of minimum energy efficiency beyond those required by the 2013 California Energy Code. Water Efficiency and Conservation Indoor Use - 4.303.1- Water Conserving Plumbing Fixtures and Fittings. - Plumbing fixtures and fittings shall comply with the following: 4.303.1.1 - Water closets flush volume shall not exceed 1.28 gals per flush. 4.303.1.2 - Urinals flush volume shall not exceed 0.5 gals per flush. 4.303.1.3.1- Single showerheads shall have a maximum flow rate of not more than 2.0 gpm. 4.303.1.3.2 - Multiple showerheads shall have a combined flow rate of all showerheads and/or shower outlets controlled by a single valve shall not exceed 2.0 gpm or only one shower outlet to be in operation at a time. 4.303.1.4.1- Residential lavatory faucets maximum flow rate shall not exceed 1.5 gpm. The minimum flow rate shall not be less than 0.8 gpm. 4.303.1.4.2 - Lavatory faucets in common and public areas of residential buildings shall not exceed 0.5 gpm. 4.303.1.4.3 Metering faucets shall not deliver more than 0.25 gals per cycle. 4.303.1.4.4 - Kitchen faucets maximum flow rate shall not exceed 1.8 gpm. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gpm. Note: When complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.2 - Plumbing fixtures and fittings shall be installed in accordance with the Plumbing Code. Outdoor Use - 4.304.1- Irrigation Controllers - Automatic irrigation system controllers for landscaping by the builder and installed at the time of final inspection shall comply with the following: 1. Controllers shall be weather- or soil moisture -based controllers that automatically adjust irrigation in response to changes in plant watering needs as weather or soil conditions change. 2. Weather -based controllers without integral rain sensors or communication systems that account for rainfall shall have a separate wired or wireless rain sensor which connects or communicates with the controller(s). Material Conservation and Resource Efficiency 4.406.1- Rodent Proofing - Annular spaces around pipes, electric cables, or other openings in sole/bottom plates at exterior walls shall be closed with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency to prevent passage of rodents. 4.408.1- Construction Waste Reduction of at least 50% - A minimum of 50% of the construction waste generated at site is diverted to recycle or salvage. 4.408.2 Construction Waste Management Plan - Submit a construction waste management plan meeting items 1-5 in Section 4.408.2. Plans shall be undated as necessary and shall be available for examination during construction. 4.408.3 - Waste Management Company - Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that diverted construction and demolition waste materials meet the requirements in Section 4.408.1. 4.408.4 - Waste Stream Reduction Alternative - Generate a total combined weight of construction and demolition waste disposed in landfills that is equal to or less than 4 lbs per sq. ft. of the building area. 4.408.4.1- Waste Stream Reduction Alternative (High -Rise Residential) - Generate a total combined weight of construction and demolition waste disposed in landfills that is equal to or less than 2 lbs per sq. ft. of the building area. 4.410.1- Operation & Maintenance Manual - An operation and maintenance manual shall be provided to the building owner or occupant. Environmental Quality 4.503.1 General Any installed gas fireplace shall be a direct -vent sealed -combustion type. Any installed woodstove or pellet stove shall comply with US EPA Phase If emission limits where applicable. Woodstoves, pellet stoves, and fireplaces shall also comply with applicable local ordinances. 4.504.1 Coverings of Duct Openings and Protection of Mechanical Equipment during Construction - Duct openings and other related air distribution component openings shall be covered during construction. 4.504.2.1- Adhesives, Sealants and Caulks - Shall be compliant with VOC and other toxic compounds limits. 4.504.2.2 - Paints and Coatings - Shall be compliant with VOC limits. 4.504.2.3 - Aerosol Paints and Coatings - Shall be compliant with product weighted MIR limits for ROC and other toxic compounds. 4.504.3 - Carpet Systems - Shall be compliant with VOC limits. 4.504.4 - Resilient Flooring Systems - 80% of floor areas receiving resilient flooring shall comply with the VOC - Schools HPS Low -emitting Materials List or to emission limits defined in the Collaborative for High Performance Sc (C ) g be certified under the Resilient Floor Covering Institute (RFCI) FloorScore Program. 4.504.5 - Composite Wood Products - Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior finish systems shall comply with low formaldehyde emission standards. 4.505.2 - Concrete Slab Foundations - A vapor retarder and capillary break is installed at slab on grade foundations. 4.505.3 - Moisture Content of Building Materials - Wall and floor framing materials shall be checked before enclosure. 4.506.1- Bathroom Exhaust Fans - Exhaust fans which terminate outside the building are provided in every bathroom. 4.507.2 - Heating and Air Conditioning System Design - Duct systems are sized , designed, and equipment selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. Installed & Special Inspection Qualifications 702.1- HVAC system installers are trained and certified in the proper installation of HVAC systems and equipment. 702.2 Special inspectors must be qualified and able to demonstrate competence to the enforcing agency in the discipline in which they are inspecting. 703.1- Documentation - Verification of compliance with the code may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods of acceptable to the enforcing agency which show substantial conformance. TABLE 4SO4.1 '4DNESIVE VOC L[MfTt.2 I,ac.-It Wfrtisr rind lLes*� Exorrst Conan undt ell Grams nor Liter AP CHITECTU`P &L APPLICATIONS CUPP ENT VO G LIMIT rrxlmrcarmtidhtsives 5 ca ,td dh niv's 5) Outdoor -c- .et adhe-�i',k-s 150 Wood 11c --fit n''I ndhc-,i+� for Rubl~cr flc--cr asihoi,v5 0.1 Suhflnnr 011miw-, f Cer3mi,: tilt ndh v s 65 '4rt'T and as halt tilt adihesK s 775 Drywall arra paneI adhssi o Yo o hi .stdhLN� ,,es AD N&i Iti . u _ . , con orrlrct ion adhe-,h) s 70 .Structura.1 pI32,inZ ntlhc-_-�Kx--s ICO Si rle:-_lvrfy.yffnenbrarradhesives 11-50 Olhm tidfr iv,- snot rry,cific-odI v listed 571 �f'IAIT�t bP�L1�ATIN L", i-mew;r y %nal rs PVC uvldinv 510 f'P'4`C wtt dingy 4T AB 15; y'r-lr ling 325 P ar,tid: t nient x -eldi n n 2517 Adtte�i ve prinwr For pla5ti c -1-550 Contain adhk iw f" c'ci ti p u . m5 wnt3cl ndh-�Ow-, 251 Structur,tl *a oro mernhe r ad h4mive l4n- 76 _ and tri nn adlic.-4ve 230 iSUBSTRATE SPEGIFiC APPLICATIONS W 1Z i W t+o 1r5C431 3,11 Plastic: fi�nms f" Porravr ma led all (eX e . t a;, cl1 V 1 �`itrttl in W ben neshe cement Coatings I. 1f: nn ndtn-sire is u sed b:� h:~nd di.ssi niilar sulbstratk s trTpkfther, the acJlx!F:ivr w-iththe highest VOCcontemshall'beallo%x d._ 2_ r:+radd itin-nail info:tmationrdparding method:: to rrnea-,u m theV(K, content spccific�d in this table. soy South Coast Air Qualitl''M na�ger nt Di%tric_t R.ul: TABLE 4504.2 SEALANT VOC LIMIT Los -9 Water and Loss Exempt Compounds in grams per Lit -r SEALANTS CURB ENT VOC LRI IT Ar-hitectuml 4 r5 Nle ri n,, && 70) Ncnmcmhr ne, F 1 Rnndv ,,iv 2'57 irudc lv rylf memhram- 0.13 Other 1_ SEALANT P PRAERS Architectur tl Nonpxntis Por us 775 Mo d it w -d hitumin owz 54 . a rim! dociz 715x" Other 7 50 TABLE 4.504.2 VOC CONTENT L.IPAITS FOR ARCI-ITECTURAL OARNGS2�9 Gram -c of VOC po r LItPr of CCiatinS Lips Wat@r and Loss Expmvt Comp COATING CATEQ0PV EFFECTIVE EFFE£T14'E 11,1tco3tin :s ' Nontl')IoIttn;�''= 1 ? Aamf l:i l -15i h g1mumatirips 1 SPECIALTY +C OATIVC; S A r a minu in nryr-f +contirlp s 0.13 Bnlv?ment'4 t miry cctntiflel 410 Ilu.minous ft, -,f :cnll.i ctr l Pi hrtninrms MiA .,nacre �1aD Lid ntd 353, Cranco 0, off rail cN- i p omnd,� -39'D M � CA7,RCVNtN'M ,`_"f'+ t rat r 1 t L", i-mew;r y %nal rs 51 .a try fop cold"I Ifo U Fawt iini5binc ccrrcatin?s O I�1 � Q' c� Fir, -L, rrtti,tis� e coatines 39-) F+� o V M Warn hic netts c li ops (stinn rots) 5M W lli h temperature contirt 42 1nduvrialnmintefian cecrtt fillps 2_:+t V 1 Low gilt' dos +."ontinpsI in W ben neshe cement Coatings a5 ttlatslk Iextwe cnoritl s IrO Morelli, ipmelit.-M omtin. � 5(1111D hisfltiic lie ". fins 25D pliet'reatment wash Pfirmer. 41131 H Ptii mrs, wal p o, aM un d]ercoote 1 ( D H Reactive ppirbrafi lip seot2rs Rkcvcic,d coat.F n ,; 2=J-) Rcxlf "dn ,3 50 Rapt f * nratr. Cyst"ttik% _V10 250 hell:r,s gar Opaque ue 730 35D SmAnit,or Primers. welds and °undereaarers 39D for) shvn! 12 stntv,� cohcrsli9tini 450 a * No. N RE 1283 7/17 F Traffic mifV1fl matin ..s ire To and the refinish gratin CALCREEN MANDATORY WalerpronFing membranes Date 2016 wo-jd rr:atimsl 217-9 Drawn Job Ztrl,&fi prim ers � , 340 7. Gmm4 o voc I-er liter of eoatft. imcludi n� wa_te.r- and i n:l udin` exempt a . 2. 'Tlr� � d~�: rf i ikd 1 imit� remain i n efil'cv::t unlr- �� t sed li mi tS- sr Listed i n s+yb s- r. quent columns in lfic uthh?:. 3. '451ues in this table are derived friars thns0 T ilie-d by that calire-mia Air If -err Boardl, Arehitecturd Coatings Suggested Cuor*rol rvleasai m T hruary 1. 2_008. ]Vlore hif-cmatirnn h tmail3blc frim 1he ,fir Re trces TABLE 4.504.5 FORMALDE"YDE LIMIT,",' Maxim, urn Porm;ald@hv Emik itions in Prig der Lfill'ion P FICIDUCT CV13REW WAIT Mardwood1 lvwor_d -�cneercom 0. CZ -1 1` ardwco di 1yyv%" -om -osi v y l rc 1O. F-, dic feboar-id McA itmi rid c ity f its rh end r?.1 F Thi n m -A iu>;n den sit3 0.13 1. N a1t1= ., in 'tbh table uv d:rii�vtil frnrn tho e Tcc'ir d by the Cali fQm1a Air ll.e: a rux-% Board, .,Air Tox i" Cont ml ]Measure For Cntnport ite N'4'oiod as toste.d in aicrinirJance -with ASnA E [333. For add itionA inf6rma6,2n_ z C4rt,'; 6.aratia C.t-de rf:Re,urt'._g.,)*oraK Title 1 7, 1-;�-- cLinns q 3 I "±f1 throuph9a 12t1_ l2 . 2_ T1un rr>,�dium � r�ih� fah trt•�xtld h,�s 3 mnMri cotton thirla�c-ss ryf=:.�e ir�h t �S moat. PERMIT # -- ��� - d2- I a - Bl1 TE COUNTY CEVELOPNIIEfvT SERVICES- 01 DATE7-�04 rj _ pY_.-AIN_6(C PMETED FOR CODE CTIPLIANCE !' AP 25 1016 ��'JPI rU WRITAS IiORTH AMERICA, ItIC. NOTE: THE PROJECT MANAGER OR OENERAL CONTRACTOR WILL BE THE RESPONSIBLE PERSON TO GOLLEGT AND PROVIDE \/ERIFIG,4TION OF GALGREEN GOMPLIANGE TO THE BUILDING INSPEGTOR PRIOR TO BUILDING SINAL. Revislon: Date: By: N n 00 W M � � L) N � .a H U u � U U O I�1 � Q' c� � W F+� o V M V 1 W V 1 W W W O H H w 7t �H V1 W I -I SSDAR A Ch' C1���ORY -J a * No. N RE 1283 7/17 F SIDENTIAL CALCREEN MANDATORY MEASURES Date 2016 Scale Drawn Job Sheet Of Sheets n. N N ti M ci CO e -I O N L\A N N