Loading...
HomeMy WebLinkAboutB16-0325 000-000-000BARRIER POST, TYP 6" I"' EC 4000A BUSSED DUCT AS REOU I RED BY PG E UTILITY TRANSFORMER PIER HOLE AS REQUIRED BY PG4E (N) 4000A MSB PRECAST q0"X106" PAD UTILITY TRAN5FORMER $ M56 DETAIL UTILITY TRANSFORMER 106" TAP r �- BOX 1-7 BUS DUCT 23" L 36.03" 25.75" 23.6" _ LARGE HE PAD 2' EO T.B.D. TOF ELEVATION MSB EQUIPMENT PAD 6" CONCRETE ' GRADE N.T.S. 4" CONCRETE PAD MAIN SWITCHBOARD T.B.D. MAIN 5N1 TCHBOARD 4 BU5 DUCT DETAIL N.T.S. T.B.D. TO FIRE PUMP PANEL 4 COMMUNICATION PANEL I -5"C 3-50OMCM� 1-4/0 GRD 1-2 "G (COMM) `\ �-� 3'X5' SPLICE BOX (POWER) N36 PULL BOX (GOMMUNICTION) 00 \\ HANDHOLE IN BASE OF POLE COMPLETE WITH GASKETED COVER. CONNECT GROUND WIRE TO POLE. FULL BASE COVER. ANCHOR NUTS ABOVE t BELOW �— FLANGE FOR LEVELING. —1 — (5) #5 TIES 2" ON CENTER. HOOK 1350 AROUND VERTICAL BAR FINISH GRADE FEEDER PER PLANS III II GALVANIZED J -BOLTS (4 REQUIRED). SIZE AS PROPOSED METAL BUILDING, WALNUT HULLER FO�,. DETAIL SEE SHEETS E2 $ E2.1 \ 0 NO SCALE �/ \• 13i5- 1-2"C (COMM) LGG-1 PANEL H/L -MGG- I SECT. 2 �� \ -MGG-1 SECT. I \ 4-3/0 I \ 1-#2 GRD \ v ' \ 2"G (PLG-I)� . \, FIRE RISER WITH EACH W/ \ BELL 4 FLOW SWITCH 3-500MGM \c�, I PANEL 1-4/0 GRD \ 24"X24" BENNER c, \ NAWMAN CABINET \ ` w \ 1"C (AT 4 T) 2 "G \ MSB PANEL HI/LI MGG -2 2"G 4-3/O / -#2 GRD M5B-2 /// EACH VV (N) SERVICE FEED TO (E) PANEL "D" // \ :2110 1-2/0 GRD \ (AT T) (E) 400A.2 -i -7/450V 3PH 4W / / i -511G (POWER) \ EXISTING WAREHOUSE BUILDING PANED"D" 4000A 277/480V \ (N) 200A 120/240V IPH SPH 4W NEMA 3R \ 4W NEMA 3R METERMAIN MSB \ WITH'GSR SERVICE RISER \ 4-5/0 SEE GD (N) OVERHEAD BUSS DUCT \\ I-#2 GRDo SERVICE PER PG$E PG 4 E TRANSFORMER N� SEE 2 \ (E) PG $ E SERVICE 4"C (PG $ E) \ / / POLE 2"0 (AT4T) /\ // (E) 4"G,PG$E PRIMARY SERVICE \ / / (E) 3' X 5' PG 4 E TERMINATION BOX \ _ DEMO (E) PG 4 E PROPOSED METAL BUILDING TRANSFORMER AG ACCESSORY / DEMO (E) U.G. 400A 2'7-1/450V 3PH 4W SERVICE Na BOX TTB / SEE3 TYP O �, / BUTT TERMINATE - TBD ��UNTy / FEB r 8 ZD16 DEVEL T "H511— �H3 11 2"G SER O�M�N1 - 3-#8 v CES VIA LCC2\\/ I-#10 GRD ®v S, NT of � 51 TE PLAN Na Box SCALE = I" = 50'0" 1--i I e-,, Copy/ REVISIONS RECOMMENDED BY POLE MANUFACTURER. (4) #4 VERTICAL REBAR WITH #3 TIES • °�• ON 12" CENTER -LINE �GONGRETE BASE. CONCRETE TO BE �„ MIN. 2500 PSI IN 28 DAYS, POURED IN NATURALLY COMPACTED EARTH HOLE Z Q/ FREE OF LOOSE DIRT OR DEBRIS. PROPOSED METAL BUILDING, WALNUT HULLER FO�,. DETAIL SEE SHEETS E2 $ E2.1 \ 0 NO SCALE �/ \• 13i5- 1-2"C (COMM) LGG-1 PANEL H/L -MGG- I SECT. 2 �� \ -MGG-1 SECT. I \ 4-3/0 I \ 1-#2 GRD \ v ' \ 2"G (PLG-I)� . \, FIRE RISER WITH EACH W/ \ BELL 4 FLOW SWITCH 3-500MGM \c�, I PANEL 1-4/0 GRD \ 24"X24" BENNER c, \ NAWMAN CABINET \ ` w \ 1"C (AT 4 T) 2 "G \ MSB PANEL HI/LI MGG -2 2"G 4-3/O / -#2 GRD M5B-2 /// EACH VV (N) SERVICE FEED TO (E) PANEL "D" // \ :2110 1-2/0 GRD \ (AT T) (E) 400A.2 -i -7/450V 3PH 4W / / i -511G (POWER) \ EXISTING WAREHOUSE BUILDING PANED"D" 4000A 277/480V \ (N) 200A 120/240V IPH SPH 4W NEMA 3R \ 4W NEMA 3R METERMAIN MSB \ WITH'GSR SERVICE RISER \ 4-5/0 SEE GD (N) OVERHEAD BUSS DUCT \\ I-#2 GRDo SERVICE PER PG$E PG 4 E TRANSFORMER N� SEE 2 \ (E) PG $ E SERVICE 4"C (PG $ E) \ / / POLE 2"0 (AT4T) /\ // (E) 4"G,PG$E PRIMARY SERVICE \ / / (E) 3' X 5' PG 4 E TERMINATION BOX \ _ DEMO (E) PG 4 E PROPOSED METAL BUILDING TRANSFORMER AG ACCESSORY / DEMO (E) U.G. 400A 2'7-1/450V 3PH 4W SERVICE Na BOX TTB / SEE3 TYP O �, / BUTT TERMINATE - TBD ��UNTy / FEB r 8 ZD16 DEVEL T "H511— �H3 11 2"G SER O�M�N1 - 3-#8 v CES VIA LCC2\\/ I-#10 GRD ®v S, NT of � 51 TE PLAN Na Box SCALE = I" = 50'0" 1--i I e-,, Copy/ REVISIONS BY Z Q/ (— o v � W i v MA 1-u nV, LL V m v �- v L Q n, Q I.L LLJ o i -L-1 nom,' m m Date 02/05/2016 Scale SHOWN Drawn ABMT Job Sheet E0 Of Sheets 3 £ i� BIANC 1W LNUT,'DRYE'RMCCZ :. ;'E d , arr• T.,. .. ..E ffi. g`r.. BIANCHI WALNU HULLER MCC" ». . Manuf. 1600 arri \1'277 480 volt 3 '` nage 4 wire Nema 1 MCC main, )3reaker w..Ntatcir' List for Hu le "°` 's 1 'Build' a.�Revisiat�: � 5 16 '.� ,. ;", ,. f r8 Plan er Bulldrn Motor # Se uence Motor Name Volt PH HP Amperag HP VFD 1 Truck dump 1 460 3 15 21 VFD 2 De -sticker 1 460 3 5 7.6 VFD 3 De -sticker 1 Mid Conveyor 460 3 5 7.6 VFD 4 De -sticker 1 Elevator 460 3 5 7.6 VFD 5 Truck dump 2 460 3 15 21 VFD 6 De -sticker 2 460 3 5 7.6 VFD 7 De -sticker 2 Mid Conveyor 460 3 5 7.6 VFD 8 De -sticker- 2 Elevator 4601 3 5 7.6 VFD 9 De -sticker Auger 460 3 7.5 11 7.6 10 De -sticker Aspirator Fan 460 3 50 65 VFD 11 De -sticker 1 Trash Conveyor 460 3 3 1 4.8 124 12 De -sticker 1 Trash Cross Conveyor 460 3 3 4.8 124 13 De -sticker 2 Trash Conveyor 4601 3 3 4.8 124 14 De -sticker 2 Trash Cross Conveyor 4601 3 3 4.8 124 15 Ho per Elevator 1 460 3 7.5 11 VFD 16 Hopper Elevator 2 460 3 7.5 11 VFD 17 Hopper Cross Conveyor 1 460 3 5 7.6 18 Hopper Cross Conveyor 2 460 3 5 7.6 19 Hopper Clean Out Conveyor 1 460 3 5 7.6 20 Hopper Clean out Conveyor 2 460 3 5 7.6 21 Hopper 1 Top Auger 460 3 3 4.8 22 Hopper 1 Trash Auger 460 3 7.5 11 23 Hopper 1 Bottom Conveyor 460 3 15 21 24 Hopper 1 Outfeed Conveyor 460 3 15 21 VFD 25 Line Feed Conveyor 1 460 3 5 7.6 VFD 26 Line Feed Conveyor 2 4601 3 5 7.6 VFD 27 Hopper 2 Top Auger 460 3 3 4.8 28 Hopper 2 Trash Auger 460 3 7.5 11 29 Hop -per 2 Bottom Conveyor 460 3 15 21 30 Hopper 2 Outfeed Conveyor 460 3 15 21 VFD 31 Hopper 2 Cross Conveyor 460 3 5 7.6 VFD 32 Line 1 Trash Auger 460 3 7.5 11 33 Line Split Conveyor 1 460 3 5 7.6 VFD 34 De -sticker 3 460 3 5 7.6 VFD 35 De -sticker 3 Mid Conveyor 460 3 5 7.6 VFD 36 Line 1 Dry Aspirator Vibration Tab] 460 3 0.54 1.1 37 Line 1 Dry Aspirator Air Lock 460 3 0.75 1.6 38 Line 1 Dry Aspirator Trash Convey 460 3 1 2.1 39 Line 1 Dry Aspirator Fan 460 3 50 65 VFD 40 Water Pump 4601 3 15 21 41 Line 1 Wash Conveyor 460 3 5 7.6 VFD 42 Line 1 Rock Tank Paddles 460 3 3 4.8 VFD 43 Line 1 Rock Tank Elevator 460 3 1 5 7.6 VFD 44 Line 1 Huller 460 3 7.5 11 VFD 45 Line 1 Huller Outfeed 460 3 5 7.6 VFD 46 Line 1 Wet Aspirator Vibration Tab 460 3 0.54 1.1 47 Line 1 Wet Aspirator Air Lock 460 3 0.75 1.6 48 Line 1 Wet Aspirator Trash Convey 460 3 1 2.1 49 Line 1 Wet Aspirator Fan 4601 3 SO 65 VFD 50 Line 1 WECO 460 3 2 3.4 51 Line 1 WECO Outfeed 460 3 5 7.6 52 WECO Rerun 460 3 3 4.8 53 WECO 3 460 3 3 4.8 54 WECO 3 Outfeed 4601 3 3 1 4.8 55 WECO 3 Auger 460 3 3 4.8 56 Line 1 Cross To Tables 460 3 0.75 1.6 57 Line 1 Sort Tables Feed 460 3 2 3.4 58 Sort Table 1 460 3 1 1 1.7 59 Sort Table 1 Trash Auger 460 3 0.5 1.1 60 Sort Table 2 460 3 1 1.7 61 Sort Table 2 Trash Auger 460 3 0.5 1.1 62 Sort Table 3 460 3 1 1.7 63 Sort Table 3 Trash Auger 4601 3 0.5 1.1 64 Re -run Greens Elevator 460 3 5 7.6 65 Line 2 Trash Conveyor 460 3 7.5 11 66 Line Split Conveyor 2 460 3 5 7.6 VFD 67 De -sticker 4 460 3 5 7.6 VFD 68 De -sticker 4 Mid Conveyor 460 3 5 7.6 VFD 69 Line 2 Dry Aspirator Vibration Tab] 4601 3 0.54 1.1 70 Line 2 Dry Aspirator Air Lock 4601 3 0.75 1.6 71 Line 2 Dry Aspirator Trash Convey( 4601 3 1 2.1 72 Line 2 Dry Aspirator Fan 4601 3 50 65 VFD 73 Line 2 Wash Conveyor 460 3 5 7.6 74 Line 2 Rock Tank Paddles 460 3 3 4.8 VFD 75 Line 2 Rock Tank Elevator 460 3 5 7.6 VFD 76 Line 2 Huller 460 3 7.5 11 VFD 77 Line 2 Huller Outfeed 460 3 5 7.6 VFD 78 Line 2 Wet Aspirator Vibration Tab 4601 3 0.54 1.1 79 Line 2 Wet Aspirator Air Lock 4601 3 0.75 1.6 80 Line 2 Wet Aspirator Trash Convey 460 3 1 2.1 81 Line 2 Wet Aspirator Fan 460 3 50 65 VFD 82 Line 2 WECO 460 3 2 3.4 83 Line 2 WECO Outfeed 460 3 5 7.6 84 Line 2 Cross To Tables 460 3 0.75 1.6 85 Line 2 Sort Tables Feed 460 3 2 3.4 86 Sort Tab]e 4 460 3 1 1.7 87 Sort Table 4 Trash Auger 460 3 0.5 1.1 88 Sort Table 5 460 3 1 1.7 89 Sort Tab]e 5 Trash Auger 4601 3 0.5 1.1 90 Sort Table 6 4601 3 1 1.7 91 Sort Table 6 Trash Auger 4601 3 0.5 1.1 92 Main Line Outfeed 460 3 5 7.6 93 Pre -dryer Conveyor 1 460 3 5 7.6 94 Pre -dryer Conveyor 2 460 3 5 7.6 95 Pre-dryerAuger 460 3 5 7.6 96 Pre -dryer Cross Auger 4601 3 5 7.6 97 1 Pre -dryer Fan 460 3 50 65 VFD 99 Huller To Dryer Elevator 460 3 7.5 11 100 Overhead To Dryer 1 460 3 7.5 11 101 Overhead To Dryer 2 460 3 7.5 11 102 Overhead To Dryer 3 4601 3 7.5 1 11 103 4 Main Auger To Sump 460 3 7.5 11 104 3 Trash Sump Short Conveyor 460 3 3 4.8 105 2 Trash Elevator 460 3 7.5 11 106 1 jTrash Overhead 1 460 3 1 7.5 1 11 109 I Sump Pump 1460, 3 1 5 1 7.6 3 £ i� BIANC 1W LNUT,'DRYE'RMCCZ :. ;'E d ; Manuf. 1200 airi 277 480 volt hale 4 wire'' Nema 1 MCC Main Breaker '�. " Revtston: 215116" Motor List for 17 er Bulldrn flan A Motor # Sequence Motor Name Volt PH HP Amperage VFD 110 Wet Cross Conveyor 460 3 5 7.6 20+/- Wall 111 Wet Bin Conveyor 1 460 3 5 7.6 Ceiling Surface 112 Wet Bin Conveyor 2 460 3 5 7.6 9'+/- Wall 113 Wet Bin Conveyor 3 460 3 1 5 7.6 '+/-Wall Surface 114 Dry Bin Conveyor 2 460 3 5 7.6 Pole Mount 30' 115 Dry Bin Conveyor 3 460 3 5 7.6 116 Dry Bin Cross Conveyor 460 3 5 7.6 117 Dryer Outfeed Elevator 460 3 7.5 11 Date 02/05/2016 118 Dryer Live Truck Dump 4601 3 5 7.6 119 Dryer Fan 1 4601 3 100 124 VFD 120 Dryer Fan 2 460 3 100 124 VFD 121 Dryer Fan 3 460 3 100 124 VFD 122 Dryer Fan 4 460 3 100 124 VFD 123 Dryer Fan 5 460 3 100 124 VFD 124 Dryer Fan 6 460 3 100 124 VFD 10' PRIMARY BU55 DUCT 2 E1 M OVERHEAD SERVICE 2 200A 120/240V IPH 3W NEMA 5R MAIN SWITCHBOARD 200/1 NAREHOU5E ONE LINE 01 A6RAM 800/3 I SHUNT I TRIP Fixture LightingF to a Schedule Type Manuf. Catalog Number Description Volt. Lamps Mounting A Lithonia IBZT54L12O/277MSE360/FP54/850/HO/SL/E High bay floures cent w/ embedded motion sensor 120/277 4-54T5HO shatter shield Air Craft Cable Suspended B RAB RABFXALED4T105SF Premium Cutoff Wall Pack m.volt 1-105W LED 20+/- Wall C Lithonia LBL4LP840 LED Surface lensed wrap around m.volt 1-50W LED Ceiling Surface D E-Conolight E-XML4WZ Exterior emergency egress light m.volt included 9'+/- Wall E Lithonia LHQMSW3Gl20 Illuminated emergencyexit light m.volt included '+/-Wall Surface F IRAB FXLED300SF/PS5-07-30WT Shoe boxflood light mounted at 30 degree anglE, m.volt 1-30OW LED Pole Mount 30' N.T.S. TERMINATION CABINET KIRK KEY INTERLOCK 4000/3-------------------------------- 6r----------2000/5 METER/MAIN SWITCHBOARD "MSB" NEMA BR PRIMARY BUSSED PULL SECTION 4000A 277/450V 3PH 4A BUSS M5B 6ROUND BU55 5"G 5-500MGMCft� 5/0 GU 1 1-4/0 GRD &ROUND FIRE PUMP PANEL UFFER, METAL, 6A5, RATER BOND AS REQUIRED PER NEC 5/4"G 250-014 4-#12 5Hp IJOCKEY PUMP 2110 4-5/0 1-#2 GRD I OOHP I P MSP ONE - L I NE 01 AC7RAM 1600/3 ( 1200/5 200/5 200/5 50/2 200/3 ( 100/3 (2 0/3 ( 2000/5 SPACE SPACE SPACE I I I I I 1 I I I I I 1 EACH A/ 11 55OMGM ALUALUM. GRD EACH W/ I EACH W/ 14 3/O 14 3/0 1 2#5 1 15-500MGM 1 5-550MGM 11-#2 GRD 11-#2 GRD 1 I-#10 GRD 11-4/0 6RD 11-2/0 GRD I 1 2000/5 MGG -I MGG -2 PANEL PANEL PANEL PANEL WELL H L HI LI -15KVA TRSNFRMR 45KVA TR5NFRMR INTEGRATED INTEGRATED POWER SYSTEM POWER SYSTEM N.T.S. NOTE: ALL WIRE THHN GU U.N.O. NOTE: ALL SUB PANELS RATED 10,000 AIr, MSB &ROUND BUSS 5/0 GU &ROUND UFFER, METAL, &A5, WATER BOND AS REQUIRED PER NEC 250-94 ELTib L �G G>� 5YMB0 L 5 15 OR 20 AMP 125V DUPLEX RECEPTACLE ® +IS" UNO 15 OR 20 AMP 125\1 DOUBLE DUPLEX RECEPTACLE @ +IS" UNO W 15 OR 20 AMP 125V 6FIC DUPLEX RECEPTACLE @ +IS" UNO 15 OR 20AMP 125V 51N6LE RECEPTACLE ® +IS" UNO 5PEGIAL OUTLET WITH TN15T LOOK RECEPTACLE. 5EE PLAN5 FOR 5PEGIFIGATION TELEPHONE OUTLET, RING 4 5TRING TO AGGE55151 E GEILIN6 v COMBINATION DATA/TELEPHONE OUTLET, RING t 5TRIN6 TO AGGE55IBLE GEILIN6, OR PRE -WIRE DEVIGE5. 5 51N6LE POLE TOGGLE 5AITGH, ® +46" UNO 52 TAO POLE T066LE SNITCH, ® +46" UNO 53 THREE -KAY TOGGLE 5AITGH, ® +46" UNO OCCUPANCY 5EN5OR, GEILIN6 MOUNTED OCCUPANCY 5EN50R, HALL MOUNTED O JUNCTION BOX, 51ZE 6 TYPE A5 INDICATED OR REQUIRED NON-FU5ED D15GONNEGT 5AITGH QF / FUSED 015GONNEGT 5NITGH, 51ZE PER UNIT LABEL ® PANELBOARD, MOUNTED A5 NOTED ON PANEL 5GHEDULE T� 015TRIWTION TRAN5FORMER, MOUNTIN6 A5 NOTED o TERMINAL CABINET, 51ZE AND TYPE A5 NOTED TELEPHONE TERMINAL BOARD: 4'X VX 3/4" PLYWOOD OR A5 NOTED W/DOUBLE DUPLEX RECEPTACLE 4 146 6RND IS FIXTURE TYPE FLUORE50ENT LIGHT FIXTURE - REGE55ED 0 FLUORE5GENT L16HT FIXTURE - SURFACE OR PENDANT MOUNTED �-1 FLUORE56ENT STRIP LIGHT - 5URFAOE OR PENDANT MOUNTED Ol DOWN LIGHT - REGE55ED -{} L16HT FIXTURE - 5URFAGE MOUNTED -6- L16HT FIXTURE - AALL MOUNTED ® EXIT LIGHT - GEILIN6 OR WALL MOUNTED EMEREGENGY/EXIT LIGHT WITH BATTERY BACK UP 51DE-MOUNT LAMP HEAD5 �P EMERGENCY LIGHTING FIXTURE - 5URFAGE MOUNTED ® CONTROL EQUIPMENT, NIE5, CONNECT A5 REQUIRED GU MECHANICAL EQUIPMENT DE516NATION / MOTOR CONDUIT RUN CONGEALED BELOA FLOOR OR FINISHED GRADE �- CONDUIT CONGEALED IN WALL OR GEILIN6 HOMERUN TO RE51PEGTIVE PANEL OR TERMINAL CABINET - UNDERGROUND HOME" TO RESPECTIVE PANEL OR TERMINAL CABINET - OVERHEAD A\' DENOTE5 # OF WIRE5. NO MARKS = 2412,1/2" G, CURVED HATCH DENOTE5 GROUND WIRE. WIRE 517E INDICATED WHEN OTHER THAN #12. eDETAIL DE516NATION: TOP NUMBER INDIGATE5 DETAIL, BOTTOM LETTERMUMBER INDIGATE5 SHEET 16 150LATED GROUND NL NIGHT LIGHT - UNSWITGHED FIXTURE WP WEATHERPROOF MT EMPTY CONDUIT WITH PULL5TRIN6 (E) EXI5TIN6 NIE5 NOT IN ELECTRICAL 5EGTION OF THESE PLAN5 4 5PE05 UNO UNLE55 NOTED OTHERINI5E MAIN 5WIT01-150ARD "M55-2" NEMA I SECONDARY PULL SECTION 2000A 2 -T -1/450V 3PH 4A BU55 800/3 I I I 2-4"G EACH W/ 1 5-600MCM 11-410 GRD I DISTRIB. PANEL PANEL PANEL HA LA A 4-3/0 4-5/0 1-#2 GRD I -I5KVA 11-#2 GRD � TR5NFRMR INTEGRATED POWER SYSTEM "I .P.5" 4 O/3 (00/5 00/5 � MAGE 13 � AGE SPACE I I I I 12-2"G I I I I 12-2"G � � � � 12-2"G EACH W/ 1 EACH W/ 1 EACH W/ 1 4-5/0 4-3/0 4-5/0 1-#2 GRD I I I-#2 GRD I 11-#2 GRD � 150KVA TR5NFRMR 150KVA TRSNFRMR PANEL I PANEL H4 L4 '15KVA TR5NFRMR INTEGRATED INTEGRATED INTEGRATED POWER SYSTEM POWER SYSTEM POWER SYSTEM 611.P.5" "I .P.5" "I .P.5" PERMIT # B(JTTE CCUNn' CEVELpP oq CODECOED PdR SERVICES TE 5 MI �I,gNce BY REVISIONS BY v z O J v � ti _ V 1 . LU .03- LH C, W l_ 0 V I t� nnV,, `� V LU --A LU m l \ � V � U Jam-- Q N � UA LLO W UA � z m L X Date 02/05/2016 Scale SHOWN Drawn ABMT Job Sheet EI Of Sheets Panel - H MOUNTING: Surface Noma 1 BY TYPE: Siemens IPS Panel TYPE: Siemens IPS Panel 200 amp 277/480 volt 3 phase 4 wire Main Breaker Cir.# 200 amp 277/480 volt 3 phase 4 wire Main Breaker Cir. # Description BRKR. POLE A B C A B C BRKR. POLE Description Cir. # 1 Warehouse Lighting 20 1 2981 Spare 4 1900 Spare 20 30 3 Air Compressor 2 3 Warehouse Lighting 20 1 20 2981 20 1 1900 6 7 1 20 1 1 4 5 Exteriorwall pack lighting 20 1 20 1 550 50 2 Spare 1900 13 1 10 11 Spare 6 7 Exteriorwall pack lighting 20 1 5501 1 20 400 13 Spare 20 3 Air Dryer 8 9 Site Lighting 20 1 Spare 600 1 20 400 Spare 1 1 I 20 16 17 10 11 Site Lighting 20 1 22 23 600 20 18 400 Spare 20 1 25 20 1 12 13 Spare 20 1 26 27 Spare 20 1 22 20 1 Spare 14 15 Spare 20 1 20 24 25 30 31 Spare 20 1 Spare 16 17 Spare 20 1 ISpare 20 1 1 20 1 Spare 20 1 Spare 18 19 Spare 20 1 Spare 36 30 31 20 1 20 1 Spare 20 21 39 32 33 1 35 20 1 Spare 40 41 Spare 34 35 22 23 Spare 42 1 40 20 36 37 0 0 26 27 2077 100 3 24 25 39 1 Spare 40 41 20 1 Spare 28 29 40 41 1 26 27 200 3 Transformer T3 900 0 0 01 20 1 42 30 31 Spare 77r;;i 0 0 2077 0 0 28 29 41 20 1 Spare 32 33 Spare 20 1 42 30 31 20 1 Spare 34 35 Spare 20 1 1 1 32 33 20 1 Spare 36 37 Spare 20 1 34 35 Spare 38 39 Spare 20 1 36 37 40 41 Spare 20 1 5614 100 3 Transformer 38 39 42 'Protide breaker lock ON attachment 900 10401 2400 4500 14400 40 41 1 1 1 6706 42 35311 3581 1150 7914 4700 9006 1 114451 82811 101561 Panel Load: 29882 = 36 Amps 36 x125% = 44 Amps Panel - HA MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel TYPE: Siemens IPS Panel 200 amp 277/480 volt 3 phase 4 wire Main Breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# 1 South canopy lights 20 1 950 50 3 Spare 2 3 Spare 20 1 Spare 4 5 Spare 20 1 4 5 Spare 20 1 Spare 20 1 20 1 I 6 7 Spare 20 1 1 30 3 Spare 8 9 Spare 20 1 6 50 2 Spare 12 13 Spare 10 11 Spare 20 1 14 15 Spare 20 1 20 12 13 Spare 20 1 20 30 3 Spare 14 15 Spare 20 1 20 1 Spare 1 1 I 20 16 17 Spare 20 1 50 2 Spare 22 23 Spare 20 18 19 Spare 20 1 25 20 1 Spare 20 21 20 1 Spare 26 27 Spare 20 1 22 23 Spare 28 29 Spare 20 1 20 24 25 30 31 Spare 20 1 Spare 20 1 26 27 33 ISpare 20 1 1 20 1 Spare 28 29 Spare 20 1 20 20 1 Spare 36 30 31 20 1 22 20 1 Spare 38 39 32 33 1 35 20 1 Spare 40 41 Spare 34 35 20 20 1 Spare 42 1 40 20 36 37 0 0 26 27 2077 100 3 Transformer TA 38 39 1 Spare 40 41 20 1 Spare 28 29 40 41 1 430 200 3 Transformer T3 900 0 0 01 20 1 42 30 31 Spare 77r;;i 0 0 2077 0 0 40 41 1 30271 01 01 Panel Load: 3027 = 4 Amps 4 x125% = 4 Amps Panel - L3 MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel TYPE: Siemens IPS Panel 400 amp 120/208 volt 3 phase 4 wire Main Breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# 1 Telephone board receptacle 20 1 360 20 1 Spare 2 3 South warehouse receptacle 20 1 1080 20 1 Spare 4 5 Spare 20 1 PLC1 -1 (120 volt control) 50 2 Spare 6 7 Spare 20 1 20 1 I 8 9 Spare 20 1 1 20 1 Spare 10 11 Spare 20 1 6 50 2 Spare 12 13 Spare 20 1 1 1 I 1 14 15 Spare 20 1 20 20 1 Spare 16 17 Spare 20 1 1 50 2 Spare 18 19 Spare 20 1 Spare 1 1 I 20 21 Spare 20 1 13 50 2 Spare 22 23 Spare 20 1 20 1 1 I 24 25 Spare 20 1 1 20 1 Spare 26 27 Spare 20 1 Warehouse receptacles 20 1 Spare 28 29 Spare 20 1 20 20 1 Spare 30 31 Spare 20 1 Spare 20 1 Spare 32 33 ISpare 20 1 1 20 1 Spare 34 35 Spare 20 1 20 20 1 Spare 36 37 Spare 20 1 22 20 1 Spare 38 39 Spare 20 1 35 20 1 Spare 40 41 Spare 20 1 20 20 1 Spare 42 1 40 20 20 360 1080 0 0 0 0 26 27 1 3601 10801 01 Panel Load: 1440 = 4 x125% _ Panel - L MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel TYPE: Siemens IPS Panel 200 amp 120/208 volt 3 phase 4 wire Main Breaker 200 amp 120/208 wll3 phase 4 wire Main Breaker Cir. # Description BRKR. POLE A B C A B C BRKR. POLE Description Cir. # `t Fire bell/riser 20 1 180 2 1260 Spare 20 20 1 Warehouse receptacles 2 3 PLC1 -1 (120 volt control) 20 1 20 360 30 3 Spare 180 2 20 1 Warehouse receptacles 4 5 HMI Panel (120 volt Control) 20 1 1 1 1 180 9 3600 50 2 Welder receptacle 6 7 Huller service recptacles 20 1 720 20 3600 1 20 1 1 1 1 8 9 Hullertask lighting 20 1 50 680 Spare 180 15 20 1 Warehouse receptacles 10 11 Electric room power and lighting 20 1 17 Spare 900 1 3600 50 2 Welder receptacle 12 13 Spare 20 1 20 1 3600 1 20 1 F 1 14 15 Spare 20 1 22 23 Spare 540 1 20 1 Warehouse receptacles 16 17 Spare 20 1 1 35 20 1 3600 50 2 Welder receptacle 18 19 Spare 20 1 Spare 28 3600 Spare 20 1 I 1 20 21 Spare 20 1 20 1 34 3600 1 50 2 Welder receptacle 22 23 Spare 20 1 1 Spare 34 35 3600 1 I T 24 25 Spare 20 1 Spare 20 1 40 20 20 1 Spare 26 27 Spare 20 1 20 1 1 Spare 40 41 20 1 Spare 28 29 Spare 20 1 430 200 3 Transformer T3 900 0 0 01 20 1 Spare 30 31 Spare 20 1 40 41 20 1 Spare 32 33 Spare 20 1 42 20 1 Spare 34 35 Spare 20 1 1 1 42 I.Provide breaker lock ON attachment 20 1 Spare 36 37 Spare 20 1 20Ll Spare 38 39 Spare 20 1 20Spare 40 41 Spare 20 1 20Spare 42 'Protide breaker lock ON attachment 900 10401 1080 12060 4500 14400 1129601 55401154801 Panel Load: 33980 = 94 Amps 94 x125% = 118 Amps Panel - LA MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel TYPE Siemens IPS Panel 200 amp 120/208 volt 3 phase 4 wire Main Breaker Cir. # Description BRKR. POLE A B C A B C BRKR. POLE Description Cir. # 1 North warehouse receptacles 20 1 900 50 2 Spare 2 3 Spare 20 1 1 Spare 1 1 4 5 Spare 20 1 30 3 Spare 50 2 Spare 6 7 Spare 20 1 1 1 1 1 1 8 9 Spare 20 1 13 50 2 Spare 10 11 Spare 20 1 1 20 1 1 12 13 Spare 20 1 1 50 2 Spare 14 15 Spare 20 1 1 20 1 Spare 20 21 —16- 17 Spare 20 1 23 50 2 Spare 18 19 Spare 20 1 20 1 1 1 20 21 Spare 20 1 29 20 1 Spare 22 23 Spare 20 1 20 20 1 Spare 24 25 Spare 20 1 35 20 1 Spare 26 27 Spare 20 1 1400 20 1 Spare 28 29 Spare 20 1 40 20 1 Spare 30 31 Spare 20 1 34 20 1 Spare 32 33 Spare 20 1 20 1 Spare 34 35 Spare 20 1 100 3 Transformer TA 20 1 Spare 36 37 Spare 20 1 40 20 1 Spare 38 39 Spare 20 1 35 20 1 1 Spare 40 41 Spare 20 1 36 20 1 1 Spare 42 430 200 3 Transformer T3 900 0 0 01 01 0 1 9001 01 01 Panel Load: 900 = 3 Amps 3 x125% = 3 Amps Panel - H4 MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel 400 amp 277/480 volt 3 phase 4 wire Main Breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# 1 Spare 20 1 50 3 Spare 2 3 Spare 20 1 -TT 1 2 4 5 Spare 20 1 Spare 20 4 6 7 Spare 20 1 30 3 Spare 8 9 lSpare 20 1 8 9 Spare 10 11 Spare 20 1 9 Spare 10 12 13 Spare 20 1 30 3 Spare 14 15 Spare 20 1 20 1 1 12 16 17 Spare 20 1 1 1 20 20 1 Spare 18 19 Spare 20 1 20 1 Spare 20 21 18 18 19 Spare 20 22 23 20 1 Spare 20 20 24 25 20 1 20 1 26 27 23 21 Spare 1 28 29 1 1 24 25 25 30 31 20 1 20 26 32 33 27 25 Spare 20 34 35 29 1 28 29 36 37 20 30 1400 100 3 Transformer T4 38 39 31 29 200 3 (E) Panel D 32 33 40 41 1 4000 33 31 Spare 42 1 34 35 0 0 0 1400 0 0 35 Panel - H1 MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel TYPE: Siemens IPS Panel 400 amp 277/480 volt 3 phase 4 wire Main Breaker Cir.# 200 amp 277/480 volt 3 phase 4 wire Main Breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# 1 Spare 20 1 3 Spare 20 1 2 3 Spare 20 1 4 5 Spare 20 4 5 Spare 20 1 1 6 7 Spare 6 7 Spare 20 1 8 9 Spare 20 8 9 Spare 20 1 9 Spare 10 11 10 11 Spare 20 1 10 11 Spare 20 12 13 Spare 20 1 1 12 20 1 Spare 14 15 Spare 20 1 1 20 20 1 Spare 16 16 17 Spare 20 1 f 20 1 Spare 18 18 19 Spare 20 1 Spare 20 1 Spare 20 20 21 Spare 20 1 20 1 I 22 23 21 Spare 1 1 Spare 1 1 24 25 25 23 Spare 20 1 20 26 27 26 27 25 Spare 20 1 28 29 1 28 29 27 Spare 20 30 31 20 1 1 4000 31 29 200 3 (E) Panel D 32 33 20 1 4000 33 31 Spare 20 1 34 35 1 34 35 33 4000 20 1 20 36 37 37 35 3552 20 2493 100 3 Transformer TA 38 39 Spare 36 37 2027 415 1 40 41 41 Spare 1 1 1949 20 42 35 42 1 01 0 01 75521 60271 5949 1400 0 0 2493 415 0 1 75521 60271 59491 Panel Load: 19528 = 23 Amps 23 x125% = 29 Amps Panel - H2 MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel TYPE: Siemens IPS Panel 400 amp 277/480 volt 3 phase 4 wire Main Breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# 1 East canopy lights 20 1 1400 30 3 Spare 2 3 Spare 20 1 2 3 Spare 20 4 5 Spare 20 1 4 5 Spare 1 6 7 Spare 20 1 6 20 3 Spare 8 9 Spare 20 1 6 I 8 9 Spare 10 11 Spare 20 1 Spare 10 11 Spare 20 12 13 Spare 20 1 12 20 1 Spare 14 15 Spare 20 1 20 20 1 Spare 16 17 Spare 20 1 20 20 1 Spare 18 19 Spare 20 1 Spare 20 1 Spare 20 21 19 Spare 20 1 20 1 I 22 23 21 Spare 20 1 Spare 50 2 24 25 23 Spare 20 1 20 1 20 1 26 27 25 Spare 20 1 Spare 20 1 28 29 27 Spare 20 1 22 20 1 30 31 29 Spare 20 1 20 1 32 33 31 Spare 20 1 20 1 34 35 33 Spare 20 1 20 1 36 37 35 Spare 20 2493 200 3 Transform er T2 38 39 Spare 36 37 Spare 415 1 31 40 41 Spare 1 1 Spare 20 1 35 42 1 Spare 40 41 1400 0 0 2493 415 0 1 36 20 1 38931 4151 01 Panel Load: 4308 = 5 Amps 5 x125% = 6 Amps Panel - L4 MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel TYPE: Siemens IPS Panel 200 amp 120/208 wit 3 phase 4 wire Main Breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# 1 West warehouse receptacles 20 1 1080 20 1 Spare 2 3 Spare 20 1 Dryer platform receptacles 20 1 Spare 4 5 Spare 20 1 4 50 2 Spare 6 7 Ispare 20 1 1 MCC2 (120 volt control) 6 I 8 9 Spare 20 1 14 20 1 Spare 10 11 Spare 20 1 20 50 2 Spare 12 13 Spare 20 1 20 1 23 Spare 20 14 15 Spare 20 1 13 20 1 Spare 16 17 Spare 20 1 Spare 50 2 Spare 16 19 Spare 20 1 20 1 I I 20 21 Spare 20 1 Spare 50 2 Spare 22 23 Spare 20 1 20 1 20 1 Spare 24 25 Spare 20 1 Spare 20 1 Spare 26 27 Spare 20 1 22 20 1 Spare 28 29 Spare 20 1 20 1 Spare 30 31 Spare 20 1 20 1 Spare 32 33 Spare 20 1 20 1 Spare 34 35 Spare 20 1 20 1 Spare 36 37 Spare 20 1 31 20 1 Spare 38 39 Spare 20 1 35 20 1 Spare 40 41 Spare 20 1 36 20 1 Spare 42 430 200 3 Transformer T3 1080 0 0 0 0 0 4 Amps 1400 0 0 Panel Load: 1400 = 2 Amps 1080 0 01 Panel Load: 1080 = 3 Amps 5 Amps 2 x125% = 2 Amps 3 x125% = 4 Amps Panel - L1 MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel TYPE: Siemens IPS Panel Cir.# Description BRKR. POLE A B C A 200 amp 120/208 volt 3 phase 4 wire Main Breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# '1 Fire bell/riser 20 1 180 900 5 Spare 20 20 1 Warehouse receptacles 2 3 Dryer platform receptacles 20 1 540 540 9 Spare 20 1 Warehouse receptacles 4 5 Dryer platform receptacles 20 1 540 11 360 20 1 MCC2 (120 volt control) 6 7 Spare 20 1 3600 1 1 14 50 2 Welder receptacle 8 9 Spare 20 1 20 3600 1 1 20 21 Spare 10 11 Spare 20 1 23 Spare 20 3600 50 2 Welder receptacle 12 13 Spare 20 1 3600 27 ISpare 20 1 I Spare 14 15 20 1 20 1 Spare 1 31 Spare 20 1 20 1 16 17 33 Spare 20 1 20 1 Spare 34 35 Spare 20 1 18 19 36 37 Spare 20 1 20 1 Spare 38 39 Spare 20 20 21 Spare 40 41 Spare 20 1 20 1 Spare 42 'Provide breaker lock ON attachment 22 23 0 0 24 25 40 41 24 25 26 27 0 0 0 0 0 0 26 27 29 28 29 32 30 31 34 35 32 33 36 37 34 35 430 200 3 Transformer T3 38 39 36 37 40 41 38 39 42 40 41 0 42 I.Provide breaker lock ON attachment 1801 540 540 8100 4140 3960 1 82801 46801 45001 Panel Load: 17460 = 49 Amps 49 x125% = 61 Amps Panel - L2 MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel 400 amp 120/208 volt 3 phase 4 wire Main Breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# 1 Warehouse receptacles 20 1 1080 50 2 Spare 2 '3 Fire bell/riser 20 1 180 2400 ,dam' FN 4 5 Spare 20 1 502 Spare 6 7 Spare 20 1 7 Spare 100 3 8 9 Spare 20 1 50 2 Spare 10 11 Spare 20 1 1 11 12 13 Spare 20 1 50 2 Spare 14 15 Spare 20 1 1 1 14 16 17 Ispare 20 1 1 50 1 2 Spare 18 19 Spare 20 1 1 1 20 21 Spare 20 1 20 1 Spare 22 23 Spare 20 1 20 1 Spare 24 25 Spare 20 1 20 1 Spare 26 27 ISpare 20 1 20 1 Spare 28 29 Spare 20 1 20 1 Spare 30 31 Spare 20 1 20 1 Spare 32 33 Spare 20 1 20 1 Spare 34 35 Spare 20 1 20 1 Spare 36 37 Spare 20 1 20 1 Spare 38 39 Spare 20 1 20 1 Spare 40 41 Spare 20 1 20 1 Spare 42 'Provide breaker lock ON attachment 39 1080 180 0 0 0 0 24 25 1 10801 1801 01 Panel Load: 1260 = 4 x125% _ 4 4 Distribution Panel A MOUNTING: Surface Nema 1 BY TYPE: Siemens Panel Board 800 amp 277/480 wit 3 phase 4 wire Main Breaker Cir.# Description BRKR. POLE A B C A B C BRKR. POLE Description Cir.# 1 Spare 100 3 200 3 Spare 2 3 1 20 1 2400 ,dam' FN 50 3 4 5 3 Warehouse lights 20 1 ++�6 2400 %3 7 Spare 100 3 200 3 Spare 8 9 1 Warehouse lights 20 1 1 1 —++ 10 11 1 6 7 Warehouse lights 20 1 12 13 Spare 100 3 50 3 Spare 14 15 Warehouse lights 20 1 2400 m 16 17 10 11 Exterior warehouse lights 20 1 Of Sheets 945 18 19 Spare 20 1 50 3 Spare 20 21 Spare 20 1 20 1 945 22 23 Spare 20 1 15 Spare 20 1 24 25 26 27 Ispare 20 1 1 28 29 18 30 31 20 1 32 33 20 21 34 35 36 37 38 39 24 25 40 41 42 26 27 0 0 0 0 0 0 1 01 OI 01 Panel Load: 0 = 0 Amps 0 x125% = 0 Amps Panel - H3 MOUNTING: Surface Nema 1 BY TYPE: Siemens IPS Panel 400 amp 277/480 volt 3 phase 4 wire Main Breaker Cir.# Description BRKR POLE A B C A B C BRKR. POLE Description Cir.# 1 Warehouse lights 20 1 2400 ,dam' FN 50 3 Spare 2 3 Warehouse lights 20 1 ' Il ■L. 2400 %3 V I tu 1 4 5 Warehouse lights 20 1 2400 —++ ' IV' 1 6 7 Warehouse lights 20 1 2400 1 30 1 3 Spare 8 9 Warehouse lights 20 1 2400 m 10 11 Exterior warehouse lights 20 1 Of Sheets 945 12 13 Exterior warehouse lights 20 1 945 30 3 Spare 14 15 Spare 20 1 16 17 Ispare 20 1 1 18 19 Spare 20 1 20 1 Spare 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 430 200 3 Transformer T3 38 39 1400 40 41 42 5745 48001::1345P4111 1400 0 1 61751 62001 33451 Panel Load: 15720 = 19 x125% _ 19 Amps 23 Amps pEPMfT # BUTTE COUNTY CEVELOP CODEVjE�NED iF IRi SERvlcss DATE DE COMPL o CE _-BY REVISIONS BY V z ++� 0 19 ul A v � Y � _r 13Uj m 6 U) ,dam' FN V ' Il ■L. M %3 V I tu V l� ' IV' m 1S V Ln Q V Q LL i Z Q LU ly LLJz m Date 02/05/2016 Scale SHOWN Drawn Ai3/MT Job Sheet ELI Of Sheets O O O "H"-5--1 VIA LGG-I HULLER ELEGTRIGAL PLAN SCALE = 1/5" = 1'0" LIGHTING CONTROL CABINET "LCC -111 PANEL GIRL.# RELAY DE50RIPTION LOCAL 5WITGH MASTER 5WITGH # T/G ZONE PG DAYLT ZONE H I I HULLER WAREHOUSE LIGHTING I `l F v 0 0� H 5 2 HULLER WAREHOUSE LIGHTING 2 i� H 5 5 EXTERIOR WALL PACK LIGHTING V I l� H 7 4 EXTERIOR WALL PACK LIGHTING lu I X 5 SPARE U Q LLLA iJL. Q 6 SPARE N� l.� z 3 7 5PARE o lum x Date 02/05/2016 Scale SHOWN Drawn ABMT 8 SPARE Of Sheets PERMIT # EUTTE p,V� DEV E�OPMENI CODE �VVSD �� SERVICES DATE --�� %CM1�"-IgNCE REVISIONS BY V z `l F v 0 0� v Q m 'y\ v n Q a i� �1■ V l� '� � LI Lu W lu X m l\ � V � U Q LLLA iJL. Q N� l.� z 3 o lum x Date 02/05/2016 Scale SHOWN Drawn ABMT Job Sheet E2 Of Sheets MCC Conduit Location Location Conduit Size Motor ID Motor Horse Power 0.5-3hp 5-7.5hp 10-15hp 50hp #14 1 #12 1 Wire Size and Quantity #10 #8 #6 #4 2/0 Cat 5E 1 11/4" 1,2,3,4,11,12 2 3 1 20 1 3 2 11/4" 5,6,7,8,13,14 2 3 1 20 1 3 3 3/4" 19,20 2 7 4 1" 15,16,23 2 1 6 1 3 5 3/4" 17,18 2 7 6 11/4" 29,30,31 1 2 3 1 6 7 11/4" 24,25,26 2 1 6 1 3 8 11/4" 32,33,34,35,36 1 4 12 4 9 11/4" 65,66,67,68,69 4 1 4 12 4 10 2" 70,71,73,74,75,76,28,22 8 3 5 12 16 11 2" 9,37,38,40,41,42,43,44 7 4 3 1 15 7 3 12 11/4" 45,46,47,48,50,51,56 7 5 2 22 13 2" 52,53,54,55,77,78,79,80,82,83,84 9 2 34 14 11/4" 86,87,88,89,90,91 6 19 15 11/4" 57,58,59,60,61,62,63 7 22 16 11/4" 64,85,92,93,94,95,96 1 6 22 17 11/4", 3/4" 97, 110 Volt Burner Control 1 3 1 3 18 11/4" 99,100,101,102 4 1 13 19 11/4" 10 1 1 3 20 11/4" 39 1 1 3 21 11/4" 72 1 1 3 22 2 - 11/4" 49,81 2 2 6 23 1" 103,104,109 1 2 6 4 24 1" 105,106 2 7 25 1", 3/4" E stop, HMI, 110 volt Control 4 14 1 NOTE: SEE EQUIPMENT MOTOR LIST ON SHEET EI �> AG WAREHOUSE BUILDING SCALE = I/ib" = l' u L I OHTI NO CONTROL GAB I NET "LCC -2" PANEL CIRO.# RELAY DESCRIPTION LOCAL SWITCH MASTER SWITCH # T/O ZONE DAYLT ZONE H3 I i WAREHOUSE LIGHTING I H5 3 2 WAREHOUSE LIGHTING 2 H3 5 5 WAREHOUSE LIGHTING 3 H3 7 4 WAREHOUSE LIGHTING 4 H5 c{ 5 WAREHOUSE LIGHTING 5 H5 it 6 EXTERIOR WALL PACK LIGHTING I H3 13 7 EXTERIOR WALL PACK LIGHTING 8 a 10 11 12 15 14 15 16 pFRM/T # FNT DA, Cpp> C MOFVE�OPM�� FSR S�Rvlcss =Y ANNE ay C STATE OF CALIFORNIA INDOOR LIGHTING CEC-NRCC.LTi-Ot-E (Revised f *'141 CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS Indoor Lighting Project Name: New Huller Dryer and Facility for Bianchi STATE OF CALIFORNIA INDOOR LIGHTING CALIFORNIA Ek FRGY COMMISSION CEC-NRCf-LT6'77 E Pews. 0&13 NRCC-LTi-01-E CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS (Page 1 of 5) Indoor Lighting Date Prepared: 0310846 Project Name: New Huller Dryer and Facility for Bianchi Climate Zone: 11 Conditioned Floor Area :69,000 YES NO FORM TITLE -Ol-E X NRcc-urr 1 submittals. ,f All Pages required on tans fora, s of Compliance, P Certificate g q Unconditioned Floor Area: Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals. General Information Indoor Lighting Power Allowance X NRCC-LIT 04-E Tailored Method Worksheets X NRCC-LIT-OS-E LineVoitageTrack Lighting Worksheets Building Type; ❑ Schools ❑ Nonresidential ❑ Relocatabie Public Schools L.] ® High Rise Residential Conditioned Spaces ❑ E] Hotel/Motel unconditioned Spaces Phase of Construction: ® New Construction ❑ Addition ❑ Alteration Methodof Compliance: ® Complete Building ElArea Category ❑ Tailored LIGHTING COMPLIANCE DOCUMENTS (select yes for each document included) _ Fordetaited instructions on the use of this andcompliance all Energy Efficiency Standards doeunenis refer to the Nonresidential Manual ublished by the Cali/ ornia Energy Commission. YES NO FORM TITLE -Ol-E X NRcc-urr 1 submittals. ,f All Pages required on tans fora, s of Compliance, P Certificate g q X NRCC-LIT-02-E Lighting Controls, Certificate of Compliance, and PAF Calculation. All Pages required on plans for all submittals. X NRCC-LIT-03-E Indoor Lighting Power Allowance X NRCC-LIT 04-E Tailored Method Worksheets X NRCC-LIT-OS-E LineVoitageTrack Lighting Worksheets Summary of Allowed Lighting Power Conditioned and Unconditioned space Lighting must not be combined for compliance Indoor Lighting Power for Conditioned Spaces Indoor Lighting Power for Unconditioned Spaces 6. Allowed Lighting Power Conditioned NRCC-LTI-03-E, page 1 Watts Allowed Lighting Power Unconditioned NRCC-LTI-03-E, page 1 Watts Office Location Installed Lighting Installed Lighting LJField InspectorectorX 17,282 X P NRCI-LTI-03-E -Must be submitted for aline -voltage track lighting integral current limiter, or for a supplementary overcurrent protection panel used to energize only line -voltage track lighting, to be recognizednized for compliance.liance. Inspector El nspec NRCC-LTI-01-E, age 4 + NRCI-LTI-04-E - Must be submitted for two interlocked systems serving an auditorium, a convention center, a conference room, a multipurpose room, or a theater to be recognized for compliance. NRCC-LTI-01-E, �a e4 + X F PORTABLE ONLY FOR OFFICES J - NRCI-LTI-06-E - Must be submitted for additional wattage installed in a video conferencing studio to be recognized for compliance. ❑ Field Inspector NRCC-LTI-01-E, page 3 + All lighting controls and equipment shati comply with theapplicable requirements in 110.9 and shall be installed in accordance with the manufacturer's fl p Minus Lighting Control Credits -i 0 - Minus Lighting Control Credits on °a o c z 3. NRCC-LTI-01-E, page 2 Watts if f s; 0.3, NRCC-LTI-01-E, page 2 Identify office area in which ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.0(a)4. o Adjusted Installed Lighting Power r t shall The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot ll meet the 17,282 Adjusted installed Lighting Power = per 4. (row 1 plus row 2 minus row 3) _ o m (row 1 minus row 31 LED, under cabinet, furniture mounted Watts Per CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance STATE OF CALIFORNIA INDOOR LIGHTING CALIFORNIA ENERGY COMb11SSION CEC-NRCC431-01-F (Revised (76113 NRCC-LTI-Ol-E CERTIFICATE OF COMPLIANCE -USER INSTRUCTIONS (Page 2 of 5) Indoor Lighting Date Prepared: 03/08/16 Prciect Name: New Huller Dryer and Facility for Bianchi S. Complies ONLY if Installed SAllowed Complies ONLY if Installed s Allowed Form/Title 6. Allowed Lighting Power Conditioned NRCC-LTI-03-E, page 1 49,800 Allowed Lighting Power Unconditioned NRCC-LTI-03-E, page 1 E] Field Inspector Declaration of Required Installation Certificates - Declare by selecting yes for all Installation Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title NRCA-LTI-02-E - Must be submitted for occupancy sensors and automatic time switch controls. ❑ Field Inspector X X NRCA-LTI-03-E - Must be submitted for automatic daylight controls. ❑ Field Inspector NRCI-LTI-01-E - Must be submitted for all buildings E] Field Inspector Office Location F NRCI LTI-02-E - Must be submitted for a lighting control system, or for an Energy Management ement Control Systemstem (FMCS ), to be recognized for compliance. LJField InspectorectorX Watts X P NRCI-LTI-03-E -Must be submitted for aline -voltage track lighting integral current limiter, or for a supplementary overcurrent protection panel used to energize only line -voltage track lighting, to be recognizednized for compliance.liance. Inspector El nspec B X NRCI-LTI-04-E - Must be submitted for two interlocked systems serving an auditorium, a convention center, a conference room, a multipurpose room, or a theater to be recognized for compliance. ❑ Field Inspector F X NRCI-LTI-05-E - Must be submitted for a Power Adjustment Factor (PAF) to be recognized for compliance. ❑ Field inspector J X NRCI-LTI-06-E - Must be submitted for additional wattage installed in a video conferencing studio to be recognized for compliance. ❑ Field Inspector Declaration of Required Certificates of Acceptance- Declare by checking all of the Certificates of Acceptance that will be submitted. (Retain copies and verify forms are completed and signed.) YES NO Form/Title X NRCA-LTI-02-E - Must be submitted for occupancy sensors and automatic time switch controls. ❑ Field Inspector shall not be traded between offices having different lighting systems. X NRCA-LTI-03-E - Must be submitted for automatic daylight controls. ❑ Field Inspector Office Installed Portable Luminaire Watts Per Square X NRCA-LTI-04-E - Must be submitted for demand responsive lighting controls. ❑ Field Inspector STATE OF CALIFORNIA INDOOR LIGHTING CALIFORNIA ENERGY COMMISSION CEC-NRCC-LT -01-E fRovised /13 NRCC-LTI-01-E CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS (Page 3 of 5) Indoor Lighting Date Prepared: 03,/08/16 Project Name: New Huller Dryer and Facility for Bianchi A separate Lighting Schedule Must Be Filled Out forConditioned and Unconditioned Spaces. Installed Lighting Power Listed on this Lighting Schedule is Only For: ❑ CONDITIONED SPACE ❑ UNCONDITIONED SPACE A. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST The actual indoor lighting power listed on this page and on the next page includes all installed led and planned portable lighting systems. ® When complete Building Method is used for compliance, list each different type of luminaire on separate lines. ❑ When Area Category Method or Tailored Method is used for compliance, list each different type of luminaire by each different function area on separate lines. ❑ Also include track lighting in schedule, and submit the track lighting compliance form (LTG -SC) when line -voltage track lighting is installed. B. Installed Portable Luminaires in Offices - Exception to Section 140.6(a) ❑ This section shall be filled out ONLY for portable luminaires in offices (As defined in §100.1). All other planned portable luminaires shall be documented on next page of this compliance form. f e .3 watts of portable lighting is planned for an office. section is used to determine I greater Stec than 0 This se p Y B p g B r e ance El Fill out a separate line for each different office. Small offices that are typical (having the same general and portable lighting) may be grouped together. This allow shall not be traded between offices having different lighting systems. Office Portable Luminaire Office Installed Portable Luminaire Watts Per Square Accountable Office Location F Schedule Foot Watts RESPONSIBLE PERSON'S DECLARATION STATEMENT Field Inspector A B C D E F G H I J S_ Signed: company: 03/08/16 PACE Engineering 03/ Address: !:cense: Installed 49,800 All lighting controls and equipment shati comply with theapplicable requirements in 110.9 and shall be installed in accordance with the manufacturer's fl p instructions in accordance with Section 130.1. -i 0 Lighting Control Schedule All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). on °a o c z portable o y an Watts if f s; 0.3, j a Identify office area in which ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.0(a)4. o Complete Luminaire Description (i.e., r t shall The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot ll meet the 3. _4 sE luminaire N d per enter zero; x G these portable luminaires o m m LED, under cabinet, furniture mounted Watts Per `- watts in this � fD m square z F32T8, one dimmable electronic ballast} are installed _ direct/indirect) Luminaire ro $ office m m foot if F> 0.3, ® ❑ 71 17 182 General Work Area - HiRh Ba 8�_ ❑ ❑ C (B x C) 50 (D/E) (F-0.3) 2 100 General Work Area - High Bay ❑ ❑ 0 0 ❑ ❑ w v _ dimmer, automatic daylight, Units ❑ ❑ a-. r a r m u I1 m a Li Li . etc.) General Work Space -High Bay Integral motion sensor -Fixture A 71 X E -❑ E E E ❑ ❑ ❑ 1:1 Enter sum total of all pages into Total installed portable luminaire watts that are greater than 0.3 watts per square foot per office: NRCC- LTI-01-E; Page 2 N RCC-LTI-01-E (Page 4 of 5) A separate Lighting Schedule Must Be Filled Out for Conditioned and Unconditioned Spaces. Installed Lighting Power Listed on this Lighting Schedule is Only For: ® CONDITIONED SPACE ❑ UNCONDITIONED SPACE C. INDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Luminaire Schedule installed Watts Location Field inspector A B C D E F G H Phone: (5-401744-0207 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: I low wattage was 2. 1 am eligible tinder Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Tide 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued fnr the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the determined Responsible Designer Name: Responsible Designer ignaaire: S_ Signed: company: 03/08/16 PACE Engineering 03/ Address: !:cense: 17'�CLS _E01 772r, Phone: ceddiing, (530)244-0202 Redding, CA 96001 49,800 All lighting controls and equipment shati comply with theapplicable requirements in 110.9 and shall be installed in accordance with the manufacturer's fl p instructions in accordance with Section 130.1. -i 0 Lighting Control Schedule All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). on °a o T General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental, m na and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, j a D ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.0(a)4. o Complete Luminaire Description3 r t shall The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot ll meet the 3 o. z3 - 5 i All installed indoor lighting shall be equipped with controls that meet the applicable Shut -OFF control requirements in Section 130.1(c). a 31am fluorescent troller, �- r - � y 3(.e, n ^ < Function area in whichw Primary accordance with Section 130.1(e). z F32T8, one dimmable electronic ballast} Shed E24.1 a. these luminaires are installed Pass Pail A 4 -Lam Fluorescent IBZ, High-Bay242 w ® ❑ 71 17 182 General Work Area - HiRh Ba 8�_ ❑ ❑ C LED, Surface mount, wrap around 50 ❑ ❑ 2 100 General Work Area - High Bay ❑ ❑ 0 0 ❑ ❑ w v _ dimmer, automatic daylight, Units ❑ ❑ a-. r a r m u I1 m a . etc.) General Work Space -High Bay Integral motion sensor -Fixture A 71 X E -❑ E E E ❑ ❑ ❑-- 1:1 ❑ D 13 Li INSTALLED WATTS PAGE TOTAL: 17,282 Enter sum total of all pages into 11 NRCC-LTI-01-E; Page 2 _......... --- __..----- - - - June 2013 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA y 3Jw4% INDOOR LIGHTING k,I ___-__....- -_ ..---- . CAI,IF'ORNIA ENERGY _QM1MNA5SI1iN CERTIFICATE OF COMPLIANCE - USER INSTRUCTIONS NRCC-LTI_M Indoor Lighting (Page 5 of 5) Project Name: New Huller Dryer and Facility for Bianchi Date Prepared: 03/08/16 DO_ CUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Author Si nature: Doeumemat on R Z 'er'!G._.._ ChrisAbrahamsen._.._-. CALIFORNIA ENERGY CO'.1M;SSION Company: PACE Engineering S ynatun• nate: 03/08/16 Address: CEA/ F R RS Certification wentaicaNtion ( applicable): 1730 South St Date Prepared: 03/08/16 City/State/: p: Phone: (5-401744-0207 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. - 2. 1 am eligible tinder Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Tide 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued fnr the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Responsible Designer ignaaire: Chris Abrahamsen Signed: company: 03/08/16 PACE Engineering 03/ Address: !:cense: 17'�CLS _E01 772r, Phone: ceddiing, (530)244-0202 Redding, CA 96001 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA Indicate if the measure applies: INDOOR LIGHTING POWER ALLOWANCE` ' CEC-NRCC-LTI-03-E fill=cased 06! 13 CALIFORNIA ENERGY CO'.1M;SSION CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E _ Certificate of Compliance - indoor Lighting Power Allowance (Page 1 of 4) Project Name: New Huller Dryer and Facility for Bianchi Date Prepared: 03/08/16 ALLOWED LIGHTING POWER (Chose Method) A separate document must be filled out for conditioned and Unconditioned Spaces. This page is used only for the following: ❑ CONDITIONED SPACES ❑UNCONDITIONED SPACES A. SUMMARY TOTALS OF LIGHTING POWER ALLOWANCES ® if using Complete Building Method for compliance, use only the total in column (a) as total allowed building watts. ❑ if using Area Category Method, Tailored Method, or a combination of Area Category and Tailored Method for compliance, use only the total in column (b) as the total allowed building watts. (a) (b) 1. Complete Building Method Allowed Watts. Documented in section B of NRCC-LTI-03-E (below on this page) 49,800 2. Area Category Method Allowed Watts. Documented in section C-1 of NRCC-LTI-03-E (below on this page) 3. Tailored Method Allowed Watts. Documented in section A of NRCC-LTI-04-E TOTAL ALLOWED BUILDING WATTS, Enter number into correct cell on NRCC-LTI-01, Page 2, Row 1 49,800 ❑ Check here if building contains both conditioned and unconditioned areas. B. COMPLETE BUILDING METHOD LIGHTING POWER ALLOWANCE Indicate if the measure applies: YES NO A B ❑ C A separate document must be filled out for conditioned and Unconditioned Spaces. This page is used only for the following: ❑ CONDITIONED SPACES ❑ UNCONDITIONED SPACES D TYPE OF BUILDING (From §140.6 Table 140.6-B) WATTS PER (ft') X COMPLETE BLDG. AREA = ALLOWED WATTS General industrial Storage Building 0.6 48,000 28,800 General Industrial Work Building- High Bay 1.0 21,000 21,000 n - o Total Area: El ® Installation Certificate shall be installed in accordance with Section 130.4(b). Total Watts. Enter Total Watts into Section A, Row 1(Above on this page) 49,800 -1 AREA CATEGORY METHOD TOTAL LIGHTING POWER ALLOWANCES (C-2 plus C-3) Watts Total from Section C-2 . Total from Section C-3 . Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance !ERS Provide) June 2013 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CEO-NRCC-LTI-02-E Revise] 06113 CALIFORNIA ENERGY COMMISSION `s '- CERTIFICATE OF COMPLIANCE NRCC-LTI-02 E Indoor Lighting - Lighting Controls (Page 1 of 5) Project Name: New Huller Dryer and Facility, for Bianchi Date Prepared: 03/08/16 Tho NR( -('-I TI -n7 -F shall hp uSPd to document all mandatory and DreSCriptiVe IiRhtinP Controls that are applicable to the project. A. Niaudatory [Aghtin; Control Declaration Statements Indicate if the measure applies: YES NO Control Requirements ® ❑ certified to the Energy Commission according to the Title 20 Appliance Lighting shall be controlled by self-contained lighting control devices which are a pp A separate document must be filled out for conditioned and Unconditioned Spaces. This page is used only for the following: ❑ CONDITIONED SPACES ❑ UNCONDITIONED SPACES C -2 AREA CATEGORY METHOD GENERAL LIGHTING POWER ALLOWANCE ❑ Do not include portable lighting for offices. Portable lighting for offices shall be documented only in section B of NRCC-LTI-01-E. ❑ Separately list lighting for each primary function area as defined in §100.1 of the Standards. Efficiency Regulations in accordance with Section 110.9. B X Lighting shall be controlled by a lighting control system or energy management control system in accordance with §110.9. An Installation Certificate ❑ D shall be submitted in accordance with Section 130.4(b). WATTS PER (ft') AREA (ft) One or more Track Lighting Integral Current Limiters shall be installed which have been certified to the Energy Commission in accordance with §110.9 and ❑ ® §130.0. An Installation Additionally, an Installation Certificate shall be submitted in accordance with Section 130.4(b). Cc pane PACE Engineering n - o i A Track Lighting Supplementary overcurrent Protection Panel shall be installed in accordance with Section 110.9 and Section 130.3. Additionally, an El ® Installation Certificate shall be installed in accordance with Section 130.4(b). C',ty/ST xejZiF: ® All lighting controls and equipment shati comply with theapplicable requirements in 110.9 and shall be installed in accordance with the manufacturer's fl p instructions in accordance with Section 130.1. ® Lighting Control Schedule All luminaires shall be functionally controlled with manually switched ON and OFF lighting controls in accordance with Section 130.1(a). on °a o T General lighting shall be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, ornamental, I ro ® and special effects lighting shall each be separately controlled on circuits that are 20 amps or less. When track lighting is used, general, display, C D ornamental, and special effects lighting shall each be separately controlled; in accordance with Section 130.0(a)4. F G r t shall The general lighting of any enclosed area 100 square feet or larger, with a connected lighting load that exceeds 0.5 watts per square foot ll meet the ❑ � multi-level lighting control requirements in accordance with Section 130.1(b). ❑ i All installed indoor lighting shall be equipped with controls that meet the applicable Shut -OFF control requirements in Section 130.1(c). ❑ ® Lighting in all Daylit Zones shall be controlled in accordance with the requirements in Section 130.1(d) and daylit zones are shown on the plans. ❑ ® Lighting power in buildings larger than 10,000 square feet shall be capable of being automatically reduced in response to a Demand Responsive Signal in Dob G?/O!S/2016 accordance with Section 130.1(e). Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE HERS Provider: lune 2013 CERTIFICATE OF COMPLIANCE NRCC-LTI-03 E Certificate of Compliance - Indoor Lighting Power Allowance (Page 2 of 4) Project Wine: New Huller Dryer and Facility for Bianchi Date Prepared: 03/08/16 D normal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in Total Watts. Enter Total Watts into section A, row 2 (Above on this page) G A separate document must be filled out for conditioned and Unconditioned Spaces. This page is used only for the following: ❑ CONDITIONED SPACES ❑ UNCONDITIONED SPACES C -2 AREA CATEGORY METHOD GENERAL LIGHTING POWER ALLOWANCE ❑ Do not include portable lighting for offices. Portable lighting for offices shall be documented only in section B of NRCC-LTI-01-E. ❑ Separately list lighting for each primary function area as defined in §100.1 of the Standards. A B X C = D AREA CATEGORY (From §140.6 Table 140.6-C) WATTS PER (ft') AREA (ft) ALLOWED WATTS Location in Building Primary Function Area per Table 140.6-C n Responsible Desigrer Signature: Cc pane PACE Engineering n - o - -Address: tieen- n CL N C',ty/ST xejZiF: Standards Complying With' w v s. ° p fl p oo O Lighting Control Schedule (,/all that apply, or enter 'E' if Exempted) on °a o T 2 a I ro 0 A B C D E F G H 1 J K L i N 1 O Type/ D s ri tion of Lighting B LH Dob G?/O!S/2016 i Drown AaVWiT J. Shed E24.1 Control (i.e.: occupancy sensor, # O w r �' �° Location in Building r automatic time switch, of Registration Number: Registration Date/Time: CA BuildingEnergy Efficiency Standards - 2013 No Compliance STATE OF CAL IFORNIA INDOOR LIGHTING - LIGHTING CONTROLS CEGNRCC-LTI-02� (Revised Ofi/13 CAI IFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E Indoor Lighting - Lighting Controls (Page 2 of 5) Project Name: New Huller Dryer and Facility for BianchiUate Prepared: 03/08/16 A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: ® CONDITIONED SPACES ❑UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST A Before an occupancy permit is granted for a newly constructed building or area, or a new lighting system serving a building, area, or site is operated for PAF Credit Calculation D normal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in F G accordance with Section a 130.4. . The controls required to meet the Acceptance Requirements include automatic daylight controls, automatic shut -OFF () q P Y Sq Ft or I Linear Ft' Additional Watts Allowed controls, and demand responsive controls. A separate document must be filled out for Conditioned and Unconditioned Spaces. This page is used only for the following: ® CONDITIONED SPACES ❑UNCONDITIONED SPACES MANDATORY AND PRESCRIPTIVE INDOOR LIGHTING CONTROL SCHEDULE, PAF CALCULATION, and FIELD INSPECTION CHECKLIST A B PAF Credit Calculation D 2 F G Primary Function Sq Ft or I Linear Ft' Additional Watts Allowed Wattage Allowance (B x C) Description(s) and Quantity of Special Luminaire Types in each Primary Function Area Total Design Watts ° ALLOWED WATTS Smaller of D or F Compliance conform to the requirements of Title 24, Part 1 and Part 6 Of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the > n Responsible Desigrer Signature: Cc pane PACE Engineering n - o - -Address: tieen- n CL N C',ty/ST xejZiF: Standards Complying With' w v s. ° p fl p oo O Lighting Control Schedule (,/all that apply, or enter 'E' if Exempted) on °a o T 2 a I ro 0 A B C D E F G H 1 J K L M N 1 O Type/ D s ri tion of Lighting B LH Dob G?/O!S/2016 i Drown AaVWiT J. Shed E24.1 Control (i.e.: occupancy sensor, # O w r �' �° Location in Building r automatic time switch, of o 0 o 0 0 0 o w v _ dimmer, automatic daylight, Units y a-. r a r m ° N m a . etc.) General Work Space -High Bay Integral motion sensor -Fixture A 71 X E E E E E E El 1:1 11 ❑ Registration Number: Registration Date%Time: CA Building Energy Efficiency Standards- 2013 Nonresidential Compliance STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE HERS Provider: June 2013 CEC-NRCC-1 TI -03-E lRev'sed 0&113 CALIFORNIA ENEHGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance - (Page 3 of 4) Project Name: New Huller Dryer and Facility for Bianchi Date Prepared: 03/08/16 TOTALS Enter slim total Area Category allowed watts into section C-1 of NRCC-LTI-03-E (this compliance form) WATTS A separate page must be filled out for Conditioned and Unconditioned Spaces. This page is only for: ❑ CONDITIONED spaces ❑ UNCONDITIONED spaces C-2 AREA CATEGORY METHOD Additional Lighting Wattage Allowance (from Table 140.6-C Footnotes) A B C2 D E F G Primary Function Sq Ft or I Linear Ft' Additional Watts Allowed Wattage Allowance (B x C) Description(s) and Quantity of Special Luminaire Types in each Primary Function Area Total Design Watts ° ALLOWED WATTS Smaller of D or F Compliance conform to the requirements of Title 24, Part 1 and Part 6 Of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Chris Abrahamsen Responsible Desigrer Signature: Cc pane PACE Engineering Dare signed: 03/08/16 - -Address: tieen- 30.SDlJth C',ty/ST xejZiF: Phone: X l� V O Ck LH l� V V LU LH Dob G?/O!S/2016 i Drown AaVWiT J. Shed E24.1 TOTALS- Enter into TOTAL AREA CATEGORY METHOD ADDITIONAL ALLOWANCES- Section C-1 HERS Provider: Registration Number: Registration Date/Time: HERS Provider: June 2013 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance June 2013 STATE OF CALIFORNIA INDOOR LIGHTING - LIGHTING CONTROLS �;. nunue u. Fonv r•nne•aica,nru '1f' CERTIFICATE OF COMPLIANCE NRCC-LTI-02-E indoor fighting- Lighting Controls (Page 3 of 5) Project Name: New Huller Dryer and Facility for Bianchi Date Prepared: 03/08/16 INSTALLED WATTS PAGE TOTAL: IF MULTIPLE PAGES ARE USED, ENTER SLIM TOTAL OF ALL PAGES HERE: 1. §130.1(x) = Manual area controls §130.0(6) = Multi Level; §130.1(c) =Auto Shut -Off, §130.1(d) = Mandatory Daylight; §.130.1(e) = Demand Responsive; §.140.6(d) _ Additional lighting controls installed to earn a PAF; §140.6(d) = Prescriptive Secondary Sidelit Daylight Controls. 2. Check Table 140.6-A for correct Factor. PA Fs shall not be traded between conditioned and unconditioned spaces. As a condition to earn a PAF, an Installation Certificate is also required to be filled out, signed, and submitted. DOCUMENTATION Al1THOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentatian Author Signature: Chris Abrahamsen c -x -✓mac " -___ Company:-RASignature Date: CEEnzineerm 03/08116 - Addra< .. U A./ tiLR5 certification identifir>ton (if a(iplx,h�el: 1730 South St e1tv/sute7ip: Phone: Redding, CA 96001 (530)244-02_02 RESPONSIBLE PERSON'S DECLARATION STATEMENT 1 certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 Of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Chris Abrahamsen Responsible Desigrer Signature: Cc pane PACE Engineering Dare signed: 03/08/16 - -Address: tieen- 30.SDlJth C',ty/ST xejZiF: Phone: Registration Number: Registration Date/Time: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance STATE OF CALIFORNIA INDOOR LIGHTING POWER ALLOWANCE HERS Provider: June 2013 CFC-NRCC-LTI-03-E Revised 06!13 CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTI-03-E Certificate of Compliance - Indoor Lighting Power Allowance (Page 4 of 4 Project Name: New Huller Dryer and Facility for Bianchi - Date Prepared: 03/08/16 1. Use linear feet only for additional allowance for white board or chalk board. All other additional Area Category allowances shall use watts per square foot. 2 . Additional watts are available only when allowed according to the footnotes on bottom of Table 146-C, which include: Specialized task work; Ornamental lighting; Precision commercial and industrial work, Per linear foot of white board or chalk board; Accent displayla and feature lighting; and Videoconferencing Studio lighting.. 3. Luminaire classification and wattage shall be determined in accordance with §130.0(c) of the Standards. DOCUMENTATION AUTHORS DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: -- Documentation Author Signature: Chris Abrahamsen Company: Signature Date: Enizineerinu 01/09116 Adds -s: CEN HERS Certification identification fif appbcabie): 1730_ South St City(SiatejZip; Phone: Redding, CA 9_6001 (530)244-0202 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify thefoliowing under penalty of perjury, underthe laws of the State of California: S. The information provided on this Certificate of Compliance is true and correct. 6. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 7. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 8. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Re<Fonsible Designer Signature: Chris Abrahamsen company: Dato Signed: PACE Engineering 03/08/16 Ad fie s License: 173..O.So uth SL-------_._ --_-__.._.._.__....----- -------------- E01272&_ ----.-._...------- .-...... - .._.. ----- -- --- ---- - ------ Qtv✓State/Zip: Phone: Redding, CA 96001 1(530)244-0202 Registration Number: Registration Date/Time: HERS Provider CA Building Energy Efficiency Standards - 2013 Nonresidential CP1•iirdT7-# June 2013 ?OU 7'r� °aU�7Y ���� c C��E dMp FART S�Rvic�s BUTTE r� LIANCE COUNTY 10 2016 U m REVISIONS BY V Q t' iJ J s A ' I I L �J !� •"� Z V inin -RU LU� 1 (� 3 04 V � 16 1Z O (O �-1 2K O X l� V O Ck LH l� V V LU LH Dob G?/O!S/2016 Soot SHOHN Drown AaVWiT J. Shed E24.1 STATE OF CALIFORNIA OUTDOOR LIGHTING CFC-NRCC-LTO-01-E (Revised D6/13) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTO-01-E Outdoor Lighting _ (Page 1 of 3) Projett Name: New Huller and Dryer Facility for Bianchi Date Prepared: 03/08/16 Project Address: Total Illuminated Hardscape Area Durham, CA 182,500ftz General Information Phase of Construction: ❑ New Construction ❑ Addition ❑ Alteration Outdoor Lighting Zone ❑OLZ-1 ❑OL7-2 ❑OLZ-3 ❑OLZ-4 (OLZ) The OLZ is: ❑ Default in accordance with §1.0-114, or ❑ Amended bythe ALIJ DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. 1 certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: hris Abra Company: 5'ignature Date: PACE Engineering 03/08/16 Address CEA/ i IERS Certification IdentHication (if applicable): 1730 South St city/state/Zip: Phone: Aeddioe. CA96001 f5341M44.02IJ2 RESPONSIBLE PERSON'S DECLARATION STATEMENT _ I certify the following under penalty of per'ury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. 1 am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. S. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Co_mp_liance is required to be included with the documentation the builder provides to the building owner at Responsible Designer Name: Responsible Designer Signature: _LhidsAhmhams.« company: Date signed: PACE Engineering 03/08/16 Address: License: 1730 South St E012726 city/state/bp: P! -,one: Reddine. CA 9600 1244-0202 LIGHTING COMPLIANCE DOCUMENTS (check box for each document included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance documents, referto the Nonresidential Manual published by the California EnergyCommissroo. NRCC-LTO-01-E Certificate of Compliance NRCC-LT0-02-E Outdoor Lighting Controls Certificate of Compliance Z NRCCATO-03-E Outdoor Lighting Power Allowance Certificate of Compliance CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance STATE OF CALIFORNIA OUTDOOR LIGHTING CONTROLS CERTIFICATE OF COMPLIANCE June 2013 Outdoor Lighting Controls Project Name: New Huller and Dryer Facility for Bianchi Date Prepared: 03108/16 STATE OF CALIFORNIA OUTDOOR LIGHTING CEC-NRCC-1-TO-01-E (Revised 06!13) t CALIFORNIA ENEPGIY COMMISSION CERIIFiCATE OF COMPLIANCE NRCC-LTO-01- Outdoor Lighting - --(Page 2 of 3) Project Name: New Huller and Dryer Facility for Bianchi Dale Prepared: 03/08/76 Summary of Allowed Outdoor Lighting Power Watts 1. Lighting Power Allowed for General Hardscape - NRCC-LTO-02-E + 6,585 2. Lighting Power Allowed for Specific Application per Unit Length - NRCC-LTO-02-E + DESIGN WATTS 3. Lighting Power Allowed for Specific Application for Ornamental - NRCC-LTO-02-E + ❑ NRCA-LTO-02-E - Must be submitted for outdoor lighting controls. ❑ Field Inspector 4, Lighting Power Allowed for Specific Application per Square Foot - NRCC-LTO 02 E + 4,109 5. Sum Total of ALLOWED Outdoor Lighting Power = 10,694 �. v CompliesONLY if Installed <Allowed d m :3 a � 6 INSTALLED Outdoor lighting from NRCC-LTI-01-E, page 4 7,160 Declaration of Required installation Certificates - Declare by checking all Installation Certificates that will be submitted. (Retain copies and verify forms are completed and signed.) ® NRCI-LTO-01-E - Must be submitted for all buildings ❑ Field Inspector ❑ NRCI-LTO-02-E - Must be submitted for a lighting control system, or for an ❑ Field Inspector Energy Management Control System (EMCs), to be recognized for compliance. DESIGN WATTS Declaration of Required Certificates of Acceptance - Declare by checking all of the Certificates of Acceptance that will be submitted. (Retain copies and verify forms are completed and signed.) ❑ NRCA-LTO-02-E - Must be submitted for outdoor lighting controls. ❑ Field Inspector Schedule of luminaires exempt from the outdoor lighting power requirements in §140. Name or Symbol Description of exempt luminaire in accordance with the exemptions Schedule of luminaires exempt from the cutoff requirements in §130.2(b) Name or Symbol Description of exempt luminaire in accordance with the exemptions Schedule of luminaires exempt from the outdoor lighting control requirements in §130.2(c) Name or Symbol Description of exempt luminaire in accordance with the exemptions MANDATORY OUTDOOR LIGHTING CONTROL SCHEDULE and FIELD INSPECTION CHECKLIST A g 1 C D t T_ Cutoff ALLOTTED WATTS DESIGN WATTS B Specific Lighting Application Standards Complying With 1 A a a Outdoor Lighting Control Schedule (./ all that apply, or enter'E' if Exempted) o pDescription3 Complete Luminaire �. v How wattage was determined r M n 3 n 3 o � tO' m o z A d m :3 a � n o A g C D E F G H I N 0 Wall pack, cutoff, RAB FXLED Type/ Description of Lighting Control (i.e. ® ❑ 28 C-4. WATTAGE ALLOWANCE PER SQUARE FOOT OF SPECIFIC AREA -Table 140.7-B ❑ Allowances for Building Facades; Outdoor Sales Lots; Vehicle Service Station Hardscape; Vehicle Service Station Canopies; Sales Canopies; Non -sales Canopies; Guard Stations; Student Pick-up/Drop-off zone: Outdoor Dining; Special Security Lighting for Retail Parking and Pedestrian Hardscape A B C D E F I G ❑ ❑ ALLOTTED WATTS DESIGN WATTS Specific Lighting Application Non -Sales Canop9,800 Wattage Allotted luminaire illuminated Area Allowance per Watts Cade or Luminaire Watts per Design Watts Allowed Watts of Application Square Foot (B x C) Symbol Luminaire Description Quantity Luminaire (G x H) (smaller of D or I) 0.205 2,009 A 4 -Lamp Lithonia IBZ 10 242 2,420 2,009 ❑ ❑ 6 1,800 motion sensor, photocontrol, outdoor # ❑ ❑ : Location and Application ofastronomical time -switch control, of o 0 0 0 CD o a Luminaires being controlled centralized time -based zone lighting Units ^ ❑ ❑ n control) ❑ ❑` ❑ El 1:1 .._-❑ ❑-� ❑ ❑ a n El ❑ -- ❑ ❑ Li ❑ El 1:1 F Li ❑ El ❑ ❑' - - ❑ ❑' INSTALLED WATTS PAGE TOTAL: 7,160 Enter sum total of all pages into NRCC-LTO- 01-E; Page 2 ❑ ❑El ❑ 0 El❑ El El ❑ ❑ I,— 7n1 I CA Building Energy Efficiency Standards - 2Q73 Nonresiaenual Campudnce STATE OF CALIFORNIA OUTDOOR LIGHTING POWER ALLOWANCES CERTIFICATE OF COMPLIANCE I Outdoor Lighting Power Allowances 1 Project Name: New Huller and Dryer Fadlity for Bianchi Date Prepared: 03J08/16 C-3. SPECIFIC WATTAGE ALLOWANCE PER HARDSCAPE AREA (Ornamental Lighting) -Table 140.7-B ❑ Allowance for the total site illuminated hardscape area. Luminaires qualifying for this allowance shall be rated for 100 watts or less as determined in accordance with Section 130.01, and shall be post -top luminaires, lanterns, pendant luminaires, or chandeliers. A g 1 C D E I F G H I 1 Cutoff ALLOTTED WATTS DESIGN WATTS B Specific Lighting Application Square Feet of Wattage Hardscape Allowance Allotted Watts (B x C) Luminaire Code or Symbol Luminaire Watts per Design Watts luminaire Description Quantity Luminaire (G x H) Allowed Watts (smaller of D or 1) Name or Item Tac pDescription3 Complete Luminaire �. v How wattage was determined r M n 3 n 3 o � tO' m o z A d o L'� " N o a Primary Function area in which these luminaires are instalbad m a a m A 4 -Lamp, IBZ, Fluorescent, Electronic Ballast 242 ® ❑ 10 1 2,420 Covered Entrances city/state/Zip: ❑ ❑ ' B Wall pack, cutoff, RAB FXLED Sum total allowance for ornamental lighting on the site:. ® ❑ 28 C-4. WATTAGE ALLOWANCE PER SQUARE FOOT OF SPECIFIC AREA -Table 140.7-B ❑ Allowances for Building Facades; Outdoor Sales Lots; Vehicle Service Station Hardscape; Vehicle Service Station Canopies; Sales Canopies; Non -sales Canopies; Guard Stations; Student Pick-up/Drop-off zone: Outdoor Dining; Special Security Lighting for Retail Parking and Pedestrian Hardscape A B C D E F I G ❑ ❑ ALLOTTED WATTS DESIGN WATTS Specific Lighting Application Non -Sales Canop9,800 Wattage Allotted luminaire illuminated Area Allowance per Watts Cade or Luminaire Watts per Design Watts Allowed Watts of Application Square Foot (B x C) Symbol Luminaire Description Quantity Luminaire (G x H) (smaller of D or I) 0.205 2,009 A 4 -Lamp Lithonia IBZ 10 242 2,420 2,009 ❑ ❑ 6 1,800 Parking Lot Allowed Watts ❑ ❑ : ❑ - TOTAL 6,585 ❑ El June c- CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance STATE OF CALIFORNIA OUTDOOR LIGHTING CONTROLS CERTIFICATE OF COMPLIANCE CERTIFICATE OF COMPLIANCE NRCC-LTO-01-E (Page 3 of 3) Outdoor Lighting Project Name: New Huller and Dryer Facility for Bianchi Date Prepared: 03/05/16 A. OUTDOOR LIGHTING SCHEDULE and FIELD INSPECTION ENERGY CHECKLIST Luminaire Schedule Installed Watts Location Cutoff Field Inspect®r A B C D E F G H I Name or Item Tac pDescription3 Complete Luminaire �. v How wattage was determined r M n 3 n 3 o � tO' m o z A d o L'� " N o a Primary Function area in which these luminaires are instalbad m a a m A 4 -Lamp, IBZ, Fluorescent, Electronic Ballast 242 ® ❑ 10 1 2,420 Covered Entrances city/state/Zip: ❑ ❑ ' B Wall pack, cutoff, RAB FXLED 105 ® ❑ 28 2,940 Entrance Walkways ALLOTTED WATTS ❑ ❑ F Shoe box floodlight, Pole mount RAB FXLED 300 ❑ ❑ 6 1,800 Parking Lot Allowed Watts ❑ ❑ : ❑ - TOTAL 6,585 ❑ El ❑ ❑ ❑ ❑` ❑ .._-❑ ❑ ❑ a -- ❑ ❑ Li ❑ El 1:1 ❑ El ❑ ❑' - ❑ i❑ ' INSTALLED WATTS PAGE TOTAL: 7,160 Enter sum total of all pages into NRCC-LTO- 01-E; Page 2 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance Outdoor Lighting Controls Project Name: New Huller and Dryer Facility for Bianchi _ Date Prepared: 03(08/1.6 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT --.._..._.__....--....._.._ 1. 1 certify that this Certificate__of Compliance doc-umentation is accurate and complete. Documentatlon Author Name Documentation Author Signature: signat Company:ure Date: PACE Engineering 03/08/1.6 Address: CEA/ PF Ps Certification Identification (x applicable): 1730 South St--.- city/state/zip: Ph -e: eddinp.. CA 96 5301244-024 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance Is true and correct. 2. lam eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the Information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Respons ble Desifgrer s191aru*e: Company: Date Signed PACE Engineering 03/08/16 _ Address: License.: 1730 South St E012776 city(Suueltio'. Phone: Redding, CA 96001 530 244-0202 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance STATE OF CALIFORNIA OUTDOOR LIGHTING POWER ALLOWANCES CERTIFICATE OF COMPLIANCE une Zuis STATE OF CALIFORNIA OUTDOOR LIGHTING POWER ALLOWANCES STATE. OF CALIFORNIA OUTDOOR LIGHTING CONTROLS CERTIFICATE OF COMPLIANCE Outdoor Lighting Controls ( Project Name: New Huller and Dryer Facility for Bianchi I Date Prepared: 03/08/16 Mandatory Outdoor Lighting Control Declaration Statements Check all that apply: ❑ Lighting shall be controlled by self-contained lighting control devices which are certified to the Energy Commission according to the Title 20 Appliance Efficiency Regulations in accordance with §110.9. ❑ Lighting shall be. controlled by a lighting control a system or energy management control system in accordance with §110.9. An Installation Certificate shall be submitted in accordance with §1.30.4(b). ❑ All lighting controls and equipment shall comply with the applicable requirements in §110.9 and shall be installed in accordance with the manufacturer's instructions in accordance with §130.1 ❑ Part -Night Outdoor Lighting Controls, as defined in Section 100.1, shall meet the requirements in Section 110.9(b)5 ❑ All outdoor incandescent luminaires rated over 100 watts, determined in accordance with Section 130.0(c), shall be controlled by a motion sensor. ❑ All outdoor luminaires rated for use with lamps greater than 150 lamp watts, determined in accordance with Section 130.0(c), shall comply with Backlight, Uplight, and Glare (collectively referred to as "BUG") in accordance with Section 130.2(b) ❑ All installed outdoor lighting shall be controlled by a photocontrol or outdoor astronomical time -switch control in accordance with Section 130.2(c)l All installed outdoor lighting shall be, circuited and independently controlled from other electrical loads by an automatic scheduling control in accordance with Section 130.2(c)2 ❑ All installed outdoor lighting, where the bottom of the luminaire is mounted 24 feet or less above the ground, shall be controlled with automatic lighting controls in accordance with Section 1.30.2(c)3 ❑ For Outdoor Sales Frontage, Outdoor Sales Lots, and Outdoor Sales Canopies lighting, an automatic lighting control in accordance with Section 130.2(c)4 ❑ For Building Facade, Ornamental Hardscape and Outdoor Dining lighting, an automatic lighting control in accordance with Section 130.2(c)5 ® Before an occupancy permit is granted for a newly constructed building or area, or anew lighting system serving a building, area, or site is operated for normal use, indoor lighting controls serving the building, area, or site shall be certified as meeting the Acceptance Requirements for Code Compliance in accordance with §130.4.(a). Outdoor lighting controls shall comply with the applicable requirements of Section 130.2(c) and Reference Nonresidential CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance CERTIFICATE OF COMPLIANCE Outdoor Lig hting Power Allowances i Proieet Name: New Huller and Dryer Facility for Bianchi Date Prepai r.d: 03J08/16 A. OUTDOOR LIGHTING POWER ALLOWANCE SUMMARY 1. General Hardscape Lighting Power Allowance (Site Total from Section B of NRCC-LTO-03-E) 6,585 2. Additional Specific "use it or lose it" lighting Power Allowances listed in each of these cells shall be identical to total allowed watts determined in Section C-1 to C-4 of N13CC-LTI-04-E. PERAPPLICATION SALES FRONTAGE ORNAMENTALLIGHTING PER SPECIFIC AREA from Section C-1 from Section C-2 from Section C-3 from Section C-4. 2,100 + I I + + 2,009 = 4,109 3, Total Allowed Outdoor Lighting Wattage (add rows 1 and 2) 1 10,694 B. GENERAL HARDSCAPE LIGHTING POWER ALLOWANCE FROM TABLE 140.7-A Initial Wattage Allowance Total General Hardscape Area Wattage Allowance (AWA) Linear WattageAllowance(LWA) (IWA) Lighting Allowance A B C D E F G H illuminated AWA per Hardscape Area Square Font AWA (A x B) Perimeter Length of General Hard=,cane LPA per Linear Foot LWA IWA CaF+G (DxE) (Watts) r675 510 6,585 120,000 0.045 5,400 1,500 0.45 (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building pernil issued for the building, and made available to the Inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be Included with the documentation the enforcement agency for all applicable builder provides to the building owner at occupancy. Responsihl� Omigner Name: Responsible Designer Signature: Abr.ahamspn D ate signed: company: - PACE Engineering 03/08/16 Address. 1730 South St U<eow: E012726 city/state/Zip: Phone: 44=02 Red&rn A B C D E F G H I J ALLOTTED WATTS DESIGN WATTS Specific Lighting Application Wattage Allotted Linear Feet of Allowance per Watts Sales Frontage linear foot (8 x C) Luminaire Code or Symbol Luminaire Watts per Luminaire Description Quantity Luminaire Design Watts (G x H) Allowed Watts TOTAL 6,585 June 2013 CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance Outdoor lighting Power Allowances - Project Name: New Hu!ler and Dryer Facility for Bianchi Dale Prepared: 03/08/1.6 sum total allowance per square foot of specific area on the site 2,70 9 DOCUMENTATION AUTHORS DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Nanea, Documentation Author signature: Shrfs Abrahams s!g Date: Company: 03/08 /08 Engineering /16 _PACE Address. CLAD Hr 45 Certification Idenrftification (appika6le): 1730 South St city/state/7p: Phone: Rieddra,1522 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer). 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. 1 will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building pernil issued for the building, and made available to the Inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be Included with the documentation the enforcement agency for all applicable builder provides to the building owner at occupancy. Responsihl� Omigner Name: Responsible Designer Signature: Abr.ahamspn D ate signed: company: - PACE Engineering 03/08/16 Address. 1730 South St U<eow: E012726 city/state/Zip: Phone: 44=02 Red&rn A CA Building Energy Efficiency Standards -2013 Nonresidential Compliance June LUl7 June 2uli June 2013 C. ADDITIONAL SPECIFIC "USE IT OR LOSE IT" OUTDOOR LIGHTING POWER ALLOWANCES ❑ The additional specific outdoor lighting power allowance shall be the smaller of the allowed lighting power or the actual lighting power used. ❑ Use Outdoor Lighting Zone (OLZ) that is documented on page 1 of NRCC-LTO-01-E to calculate the specific wattage allowances. C-1. SPECIFIC WATTAGE ALLOWANCE PER APPLICATION -Table 140.7-B ❑ Available only for Building Entrances or Exits; Primary Entrances to Senior Care Facilities, Police Stations, Hospitals, Fire Stations, and Emergency Vehicle Facilities; Drive Up Windows; Vehicle Service Station Uncovered Fuel Dispenser A B C D E F G H I J I r 14 K STATE OF CAL IFORMA 33 .7 ` u OUTDOOR LIGHTING POWER ALLOWANCES 2,100 ENERGY COPAMISSIOIN CEC_NRCC-Lt0-03-ESRevsed 06113;+ .-__gAUFORN16 CERTIFICATE OF COMPLIANCE Outdoor Lighting Power Allowances Project Name: New Huller and Dryer Facility for Bianchi Date Prepared: 03/08/16+rxk'`^e"f'' C. ADDITIONAL SPECIFIC "USE IT OR LOSE IT" OUTDOOR LIGHTING POWER ALLOWANCES ❑ The additional specific outdoor lighting power allowance shall be the smaller of the allowed lighting power or the actual lighting power used. ❑ Use Outdoor Lighting Zone (OLZ) that is documented on page 1 of NRCC-LTO-01-E to calculate the specific wattage allowances. C-1. SPECIFIC WATTAGE ALLOWANCE PER APPLICATION -Table 140.7-B ❑ Available only for Building Entrances or Exits; Primary Entrances to Senior Care Facilities, Police Stations, Hospitals, Fire Stations, and Emergency Vehicle Facilities; Drive Up Windows; Vehicle Service Station Uncovered Fuel Dispenser A B C D E F G H I J ALLOTTED WATTS DESIGN WATTS Allotted Luminaire Specific Lighting Number of Wattage Watts Code or Luminaire Watts per Design Watts Application Luminaires Allowance IS x C) Symbol Luminaire Description Quantity luminaire (G x H) Allowed Watts Building Entrance 28 75 2,100 B Wall Pack Surface Mount 28 105 2,940 2,100 Sum total allowance per application on this site: 2,100 C-2. WATTAGE ALLOWANCE PER UNIT LENGTH (Sales Frontage) from Table 140.7-B A B C D E F G H I J ALLOTTED WATTS DESIGN WATTS Specific Lighting Application Wattage Allotted Linear Feet of Allowance per Watts Sales Frontage linear foot (8 x C) Luminaire Code or Symbol Luminaire Watts per Luminaire Description Quantity Luminaire Design Watts (G x H) Allowed Watts sunt total allowance for sales frontage on the site: CA Building Energy Efficiency Standards - 2013 Nonresidential Compliance JuneluJ3 PERMIT # BUTTE COUNTY pEVELOP CODE PREVIEWEDNrsERvrCEs DgTE� DEC MI L:IqNE 02