March 2, 2016 AES P.O. Box 9231 Chico, CA 95927 Re: Structural capacity of existing roof to support new solar panels Owner: Kimura Real Properties, LLC. (Small Dryer) Location: 95 Township Road, Gridley CA 95948 APN: 021-220-023-000 Streamline Job No.: 2304 To Whom It May Concern: Per this letter we are approving the existing roof framing of the Kimura small dryer existing metal building to support the addition of new solar panels. The panels will be placed on top of the existing roof as shown on plans prepared by AES. The building is located at 95 Township Road in Gridley, CA. The panels and support framing are designed by others to resist the minimum loads required by the 2013 CBC. The panels are Q.Pro L -G4 Commercial Solar Panels provided by Q Cells and are about 6.5' long x 3.3' wide each. They will be installed by Alternative Energy Systems of Chico. The panels weigh 52.9 pounds each which translates to 2.76 psf of additional dead load to the roof. The SM Solar Mount support framing is designed by others and will attach to the steel purlins below. The existing roof structure for the building is comprised of steel Z purlins spaced at a maximum of 5'-0" based on plans provided by AES dated 01-28-2016. Based on our observation and the fact that the area covered with panels will not be . loaded with the 20 psf live load required by code and included in the original design of the roof system due to the fact,that love loads will not be placed on top of the solar panels we are approving the addition of solar panels to the roof. These findings are based on my professional opinion and are not intended as a warranty of any land. Please contact me if you have any questions at 530-892-1100. Sincerely, jV Jeff Richelieu, PE President Streamline Engineering, Inc. Page 1 of 1 PtpMfIY 53ALL G / BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE MPLIAIVC DATE L [ BY 0 CA<�F 60 Independence Cir., Ste. 201 0 Chico, CA 95973 9 (530) 892-1100 • Fax: 892-1115 The polycrystalline solar module Q.PRO L -G4 with power classes up to 320 W is the strongest module of its type on the market globally. Powered by 72.Q CELLS solar cells and with a -size of 1:9 m2 Q.PRO L -G4 was' ,specially designed for large solar power plants to reduce"BOS costs: But .there is even more to our polycrystalline modules. Only Q CELLS offers German engineering quality with our unique triple Yield Security. '. LOW ELECTRICITY GENERATION COSTS " �J Highei yield per surface area and lower BOS costs thanks to higher power classes and an efficiency rate of up to 16.3 %. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior.. ENDURING HIGH PERFORMANCE Long-term yield security with Anti -PID Technology', Hot -Spot -Protect and Traceable Quality Tra.QTM LIGHT -WEIGHT QUALITY FRAME High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (2400 Pa). O A RELIABLE INVESTMENT ; Inclusive -12 -year product warranty and 25 -year linear performance_ guarantee2. LL / q %PERMIT # b16 ' 0 q&L BUTTE COUNTY DEVELOPMENT SEF !CODEREVIEWED F& Cry LI ,,, L UHIE .31 �RY CI. THE IDEAL SOLUTION FOR: Ground -mounted solar power plants f Engineered in Germany OCELLS HELD SF - TY 72015 RAND-PV- • 4 L RWE *1"10T -110T PRIME VO�'TRACEABIE QUALITY Ph Wt,,. _.• OCCLLS Best polycrystalline - solar module 2013 D.PRD.G2233 .D. �..wl.a ' APT test conditions: Cells at -1000v against grounded, with conductive me- tal foil covered module surface, 25°C, ' 168h , -2 See data sheet on rear for further r information. OCELLS Format 78.5 in x 39.4 in x 1.38 in (including frame) a.P q n,00.IS NA mm1 ..Pal . W. 0..a. 0.4r 111.0. I IA mm1 .. aq.S.-OIa00mn1- I mWm0- P.� . ,.mmw.m.lo<..PM ..P,1.„.l.n°.Ia.°.:,•la..mm, (1994 mm x 1000 mm x 35 mm) 320 j 52.9 Ib (24 kg) - - I Front Cover 0.12 in (3.2 mm) thermally pre -stressed glass with anti -reflection technology j Back Cover Composite filmy Frame Anodised aluminum Cell --` - __- 6 x 12 solar cells Junction box 3.35-4.13 in x 2.36-3.15 in x 0.59-0.67 in (85-105 mm x 60-80 mm x i _ 15-17 mm), Protection class_a IP67, with bypass diodes _ Cable 4 mm' Solar cable; (,T^ (1200 mm), (-) 2 47.24in (1200 mm)_- 45.29 45.53 { Connector Amphenol H4, IP68 eS l�! 0'mm OWER 'TEARS a.P q n,00.IS NA mm1 ..Pal . W. 0..a. 0.4r 111.0. I IA mm1 .. aq.S.-OIa00mn1- I mWm0- P.� . ,.mmw.m.lo<..PM ..P,1.„.l.n°.Ia.°.:,•la..mm, 315 --I �I.aealmml l.o•al. moll I�Io.aa•n.smml PCLASS OWER 'TEARS 310 315 320 j _- - - - - --_- - _ MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5W/- OW) cUs r Power at MPP' PMPP IW) 310 315 320 i Short Circuit Current* ISE [A] 8.99 9.06 9.13 1 E Open Circuit Voltage* 1 Vac [V] 45.29 45.53 45.76 Current at MPP* - IMPP [A] _ 8.39 8.46 8.53 Voltage at MPP* i� VMPP - IV] ` 36.96 37.24 37.53 Efficiency' q [%] >_ 15.5 z 15.8 216.0 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NOC3 _ Max Load (UL)z -[lbs/ft'] tj Power at MPP' PMPP IW] 228.9 232.6 236.3 ! E Short Circuit Current* !ff Isc [A] 7.25 7.31 7.36 e Open Circuit Voltage* Voc [V] 42.16 42.38 42.60 Current at MPP* m IMPP [A] 6.56 6.62 6.67 Voltage at MPP* VMPP IV] 34.88 35.14 35.41 spectrum AM 1.5G ' Measurement tolerances STC x3%; NOC x5 % 3800 W/m=, NOCT, spectrum AM 1.5G • typical values, actual values may differ Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE OCELL! __ 1MY7.t°,dmtl lv lvia..nnOn' Iiq,mry uaNvO bti.,W .annOq' o ! o n M n At least 97 % of nominal power during - �---r--r--r--r--r--r-r--r--a first year. Thereafter max. 0.6% degra- dation per year. - LJ At least 92 % of nominal power after 10ears. ' � Y � vo__J At least 83 % of nominal power after - I 25 years. � � ---r--r--r--r-�--�--�--�-- � All data within measurement tolerances. ao zoo xn .m Soo Em zm eEo Soo l000 Full warranties in accordance with the warranty terms of the Q CELLS sales IRRADIANCE (W/mI] organisation of your respective country. EwwO . mwc°nO ,MPu.I.,P.°vw°cuo„ 'TEARS 29 22 The typical change in module efficiency at an irradiance of 200 W/m' in relation - _1n�aoLlw m s.w«wmzoll, 80.6 in x 44.5 in x 47.6 in x 1130 x 1208 mm) cUs to 1000 W/m' (both at 25'C and AM 1.5G spectrum) is -2% (relative). z TEMPERATURE COEFFICIENTS Pallet Weight 1629 lb (739 kg) Temperature Coefficient of IS, a [%/K] +0.04 Temperature Coefficient of Vw �p [%/K]� 0.30 Temperature Coefficient of PMPP _ Y- [%/K] _ 0i41 Normal Operating Cell Temperature NOCT - [°F] 113 PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage Vsys IV] 1500 (IEC) / 1000 (1JU Safety Class II I i Maximum Series Fuse Rating (A DC] 15 Fire Rating C / Type 1 Max Load (UL)z -[lbs/ft'] 75 (3600 Pa) Permitted module temperature -40°F up to +185°F on continuous duty (-40°C up to +85°C) Load Rating (UL)' -� [Ibs/ft'] 33 (1600 Pa) z see installation manual I IEC 61215 (Ed.2); IEC 61730 (Ed. 1), Application class A This data sheet complies with DIN EN 50380. Number of Modules per Pallet -•- Number of Pallets per 40' Container 29 22 E(2047 Qt, Pallet Dimensions ( L x W x H) 80.6 in x 44.5 in x 47.6 in x 1130 x 1208 mm) cUs U- _.1. .1. Pallet Weight 1629 lb (739 kg) NOTE: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Hanwha SolarOne U.S.A. Inc. 300 Spectrum Center Drive, Suite 1250, Irvine, CA 92618 1 TEL +1415 52142 74 1 EMAIL us.sales®hanwha-solarone.com Engineered in Germany OCELLS �-SUNNY;-TRIPOWER 120O0ITL S I 1S0+00Ti1'rUS/. , .•• � ' ;L O LJ T -'/14,0100VIVI.IS�-3O000T ..0N BUTTE CQt h;Tv nFyu 1:0PMENRVICES Rf°r„0_ Cly C�°V�11�1C DATE V (�+N�ip� BY J d • � 1 t t ' r � _ RATED FOR 1000 V DC & 600 V DC SYSTEMS -- j @)V& 0 sunsp- CerUOed;t * Design flexibility System efficiency Enhanced safety Future -proof • 1000 V DC or 600 V DC • **98.5% CEC, **98.6% Peak • Integrated DC AFCI • Complete grid management feature set • Two independent DC inputs 1000 V DC increases system • Floating system with all -pole • Integrated Speedwire, WebConnect, 15° to 90° mounting angle range efficiency sensitive ground fault protection ModBus interface --Detachable DC Connection Unit • OptiTrac Global Peak MPPT • Reverse polarity indicator in • Bidirectional Ethernet communications k t combination with Connection Unit • Ufilityinteractive controls for active and reactive power - f w .SUNNY TRI POWER I2000TL-US r 15000TLx USs� ' 20000TL—US / 2400OTL-US / 30000TL—US '``t • : #' -. ;The ultimate solution for decentralized PV"plants, 'now 'up to 30 kilowatts' y The`" -world's best-selling three-phase PV inverter, the SMA Sutiny Tripower TL -US, is raising the bar for decentralized commercial' ' ,PV systems.'This three-phase, transformerless inverter is UL listed for up to 1000 V DC maximum system wbltage;and•has a. 1 r peak efficiency above 98 percent, while OptiTrac Global Peak minimizes the'effects of shade for,rnaximum energy production.w POE EG�..1' TheSunny Tripower delivers a future -proof solution with full grid management functionality cutting�edge'communications and t # • adv46nced monitoring. The Sunny Tripower is also equippedwith all -pole ground fault protection a d integrated AFC for a safe, o reliable solution. It offers unmatched flexibility with a wide input voltage range and two independent MPP trackers Suitable for both 600 V DC and 1,000 V DC applications, the Sunny Tri power allows for flexible design and a lower Ieve Iized cost of energy, www,SMA-America com �. j. �. m �' ;�` .t. - j eta. C:� -S •.r' it .1 � .i', 1 '.� }" �. �_..,r. - - fir - ' - . .. _. '- t• _ S .. .'►ter �} 4. l+ ,. J, - • �#'• ♦ _. Technical datait SunnyTripovver Sunny Tri ower Sunny Tripower Sunny Tri ower S Unny powerd 12000TL-US 15000TL-US 2000OTL-US 24000TL-US @�-060—OiL-US Input (DC) 96 -Mqx. usable DC power (9 cos q) 12250 W 15300 W 20400 -W 24500 W 30800 W -- Max. DC voltage 1000 V 1000 V 1000 V 1000 V 1000 V 94 Rated M PPT voltage range- no V - .. nov -366V 800 V 380 V...800 V 450 V...800 V 500 V...800 V MPPT operating voltage range 150 V... 1000 V j 150 V ... 1000 V j 150 V...1000_ V 150 V ...1000_V 150 V...1000 V, Min. DC voltage start voltage 150 V 188 V 150 -V /-168 V 150 V 188 V -1 50V 188 V 150V/ 188V -----Numberof MPPtrackerinputs 2 2- 2 2 Max. input current / per MPP tracker -input- 66 A,/ -66A/33--A----' 66.A / 33 A Ela IV, 500 V) Output (AC) :86 Eta IV, - 716 V) XC nominal power-_ 500 Soo -W- 2&0 ------m00-w/- 24060 W 36666 vv Max. AC apparent power 1266o VA 15600 VA 20000 VA 24060 VA 36000 VA _Out putphas es / line connections 3 3 -N -PE j 3_/ 3 -N -PE 3 -PE Nominal AC voltage 0.4 Output 0.6 0.8 1.0 Rated 480 277 V WYE -J480 A80. -/,277V -V Delta AC voltage range 244 V...305 V a -d R - te AC grid freclyeric 60 Hz ACgrdfr querrange -cy /H -,0..+5Hz_Max. output current ... 14.4A 18 A— 24 A ....... 29 A 36.2A factor at rated power adjustable displacement -4ormonics 1 /0.0leading ... 0.0 logging - - <3 % - Efficiency Max. efficiency /-C-kqAckency 1 5'. 98.2 % 97.5% 98.5% 97.5 % 98.5% 98.0% i 98.6% *98.5 Protection devices __DC reverse polority-protection 1 Ground fault monitoring /grid monitoring_ All -pole sensitive residual current monitoring unit I DC AFCI compliant to UL 16998 AC short circuit --9q ciV protection Protection qLclass/-kveryoltag@ category -, j , V V General data Dimensions (W/H/_D)inmm(in) 665_/ 650 2.65_(26 2 25.6 10.4)_ _ Packing dimensions (W/H/P)-in-mm(in)_ 780/790/ HO (30.7/ 211.1 15.0) Wei g1vt j 55 k (12 1 lbs) Packing weight 61 kg (134.5 lbs) Operating temperature range - -25 -C...+60 -C -_ internal con�_ tion at night Noise emission Itypica I � /-in ump 51 d B(A) 1 W TOPRI-0-gy-nigh Transformerless -tooling concept rating_ -protection -i _�77 V AC Derating iqt 45'�C-52�C Features Display/ LEindicators (Status Fault Dj-- torsStas --(- - _Communication) 7 111 Interface: RS485 medwire, WebConnect -/Sp Data interface: SMA Mccf6us-/ SunS pec ModBus 0 * Mourvting angle range] -90 15*- Warranty: 19 15 /20 -years Certifications and approvals UL 1741, UL 1998, UL 16998, IEEE 1547, FCC Part 15 lClass A & B), CAN C22.2 107.11 NOTE: US inverters ship with grqytids,. Data of nominal conditions. *Suitable for 600 V DC max. systems **Prelimi!to ryclato - 0 Standard features 0 Optional features Not available Type -cle�i9riqtion --- - - - _STP inomus:io', sip-mom-ILIS-1 0 _STP nodooT-L-1.1 US101, STP 2- 6-1 _4_000TIL-US-10-, - --,Yo6dqTfuswqj STP__ Accessories RS485 interface Connection Unit SMA Cluster Controller DM.485C&US-10 CU 10MUS-10 CLCON-I 0 —1 — I.......... ------------------------------------------------- ....... . ..................... i Efficiency curve SUNNY TRIPOWER 3000OTLJJS i ---------------------------- i 98 ..........................................o( power power .................... ... .................................... ... 96 94 2 r 90 Ela IV, 500 V) 7 :86 Eta IV, - 716 V) 1 500 Soo Etv, 800 V) V,„, _ IV]fj 0.0 0.2 0.4 Output 0.6 0.8 1.0 Rated 2 Bo ��g SMS6LA� BONDING CONNECTION GROUND PATHS; M❑ ❑O MOULT INSTALLATIONCUIUE;PAGE _ _ :�35ERR'ATED BONDING MIDCLAMP ASSEMBLY ©Stainless steel Midclamp points, 2 per module, pierce module frame anodization to bond module to module through clamp. © Serrated flange nut bonds stainless steel clamp to stainless steel T -bolt ® Serrated T -bolt head penetrates rail anodization to bond T -bolt, nut, clamp, and modules to grounded SM rail. ENDCLAMP ASSEMBLY ©Serrated flange nut bonds aluminum Endclamp to stainless steel T -bolt Serrated T -bolt head penetrates rail anodization © to bond T -bolt, nut, and Endclamp to grounded SM rail Note: End clamp does not bond to module frame. -BONDING RAIL SPLICE BAR Stainless steel self drilling screws drill and tap Ointo splice bar and rail creating bond between splice bar and each rail section Aluminum splice bar spans across rail gap to © create rail to rail bond. Rail on at least one side of splice will be grounded: Note: Splice bar and bolted connection are non-structural. The splice bar function is rail alignment and bonding. Note: Only one lug per module BONDING MICROINVERTER row required MOUNT 0 0 00 r 0 � w m a f' j� O�ZL $A v~i -Z' _ 4A_ 'OUNTY� CLO°�dENT ScRVECESScRVECES l \/I E51 ED FOR "A LIA LLS DA I F __ 1 i�5,C%E BY G✓ _ BONDING RAIL SPLICE BAR RAIL TO L -FOOT w/BONDING T -BOLT -BONDING RAIL SPLICE BAR Stainless steel self drilling screws drill and tap Ointo splice bar and rail creating bond between splice bar and each rail section Aluminum splice bar spans across rail gap to © create rail to rail bond. Rail on at least one side of splice will be grounded: Note: Splice bar and bolted connection are non-structural. The splice bar function is rail alignment and bonding. RAIL TO L -FOOT w/BONDING T BOLT OSerrated flange nut removes L -foot anodization to bond L -Foot to stainless steel T -bolt ©Serrated T -bolt head penetrates rail anodization to bond T -bolt, nut, and L -foot to grounded SM rail BONDING MICROINVERTER MOUNT OHex nut with captive lock washer bonds metal microinverter flange to stainless steel T -bolt © Serrated T -bolt head penetrates rail anodization to bondT-bolt, nut, and L-footto grounded SM rail System ground including racking and modules may be achieved through the trunk cable of approved - microinverter systems. See page I for details RACK SYSTEM GROUND OWEEB washer dimples pierce anodized rail to create bond between rail and lug ©Solid copper wire connected to lug is routed to provide final system ground connection. NOTE: Ilsco lug can also be used when secured to the side ofthe rail. See page 1-3 for details 16 0 r RAIL TO L -FOOT w/BONDING T BOLT OSerrated flange nut removes L -foot anodization to bond L -Foot to stainless steel T -bolt ©Serrated T -bolt head penetrates rail anodization to bond T -bolt, nut, and L -foot to grounded SM rail BONDING MICROINVERTER MOUNT OHex nut with captive lock washer bonds metal microinverter flange to stainless steel T -bolt © Serrated T -bolt head penetrates rail anodization to bondT-bolt, nut, and L-footto grounded SM rail System ground including racking and modules may be achieved through the trunk cable of approved - microinverter systems. See page I for details RACK SYSTEM GROUND OWEEB washer dimples pierce anodized rail to create bond between rail and lug ©Solid copper wire connected to lug is routed to provide final system ground connection. NOTE: Ilsco lug can also be used when secured to the side ofthe rail. See page 1-3 for details HERMIT# BUTTE GOUNTY 0F," nti Fit is CODE COI\X...3-, t� _ = Pjm;-�_ DAE - ' EJOT Solar Fastenings - Technical Data Sheet Screw - Options Material of the substructure Wood Steel Recommended screw 1A3 -S8 123 -SB • O•N Diameter (d) of the setscrew (inches) 0.394 (M10) Lg L5.906 0.394 (M10) LS Length (Lg) of the setscrew (inches) 1.969 1.969 2.756 2.756 Special length Special length • Screw diameter D inches 5116 U16 Length (L) of the screw (Inches) 3.150 2.520 3.937 3.150 5.118 3.937 5.906 4.921 7.087 7.874 6.299 Special length ` • Special lengths on request possible Determination of the screw length Wood substructure Steel substructure • O•N • f 240 N i V N � r C ■ O 0 L t L t e , ti 00 d � N r v minimum thickness of the building r Q6 c element Y= l.Smm / 0.0625 c v inches (gauge 16 (USG - US `-tom. u Standard Gauge for Stainless Steel)). �o Length of the thread L = h + ti + 0.394 inches Length of the thread L = h + 0.787 inches Recommended screw-in depths (til in wood substructure: - ti =1.260 inches • 3.M inches " Special length' EJOT• The Quality Connection " System Specifications ' Customer Name: KIMURA REAL PROPERTIES, LLC. Panel Specifications W Customer Address: 95 TOWNSHIP RD., Gridley, CA 95948 Manufacturer: Hanwha Q -Gell ;-- ". Model:Q:PRO- ~ -G4 3 y. Service Panel Bus Bar Rating: 800,1A '- _ •PV.Pmax: 315 W Length: 78.5 inches + Service Penel AC paramters: 480 V - r Vmpp: 37.24 V Width: 39.4 inches ' ,Total Solar AC System Siie: 30 kW; ' .^Voc: 45.53 V Weight: 52.9 lbs Min Service Pariel CB Size: 800 A- f11; ni r r°- _ ; Impp: 8.46 A ' , Voc % Temp: 0.0030 V 4 _ Area Lowest Temp: -3 'C ' `' r Isc: 9.06 A `, Voc'Temp: 0.13659 V - Inverter Manufacturer SMA , "A" Inverter ModSTP el 30000TL-US-10 Inverter Output Power 30000 W ' Inverter Imax36.2 A Min CB Size 45.3 A ° _ ` Strings 0 01 Actual CB Size _SOA 2 Strings of,. 20 Voltage 480 VAC ' -Array ' String DC Operating Voltage 744.80 744.80 VDG .'. DC Max Voltage 989.82 989.82 VDC ' -DC Operating Current 42.30 8.46 A ` DC Short Circuit Current 45.30 9.06 A PERMIT# /,, .�• BLIT -7: COUNTY DEVEL^?MENT SFRVIGES Notes i^ Formulas nl; NEC, Annex C, Annex C Table C ? _ fl, Isc x 1.25 x 1.25' .: f7,# of series panels in series x Vmpp ' n2, Conduit fill, NEC Table 330.15(6) (2)(a) - � •. � _ _ '. f2, Isc x 1.25/Conduit fill x (Ambient Temp -Sunlight Exposure Correction •. f8,# of series panels x ((26C + Record Low Celcius'x panel Voc temp Coef) + n3; Temp correction, NEC Table 310.16 Factor) :` Voc)) n4, DC Resistance, NEC Chapter 9 Table 8 f3, Inverter Imax x 1.25 .. ` f9,# of strings x Impp n5, AC resistance; NEC Chapter 9 Table 94 '", �_ - f4, Inverter Imax x 1.25/Conduit fill x (Ambient Temp - Sunlight Exposure f10,# of strings xlse ' n6, NEC Article 310.15 ;, ' • Correction Factor) t fll,Bus Bar or conductor rating x 1.2 - Sum of all Input Breakers <or= Bus n7, NEC Article 690.8(8)(1) . :'. f5; Tolerance % x WD x I x.2 bar or conductor rating x 1.2 n8; Sunlight Exposure,NEC Table, 310.15(B)(2)(c) F6_2 x D x I x R/V L - ' Notes i^ Formulas nl; NEC, Annex C, Annex C Table C ? _ fl, Isc x 1.25 x 1.25' .: f7,# of series panels in series x Vmpp ' n2, Conduit fill, NEC Table 330.15(6) DC Circuit Ampacity Calculator r Meter #: 1006714411 _ . a Customer Name: KIMURA REAL PROPERTIES, LLC. , Location: 95 TOWNSHIP RD., Gridley, CA 95948 t , Wire Note: DC-1 Description: ARRAY TO JUNCTION BOX - Wire Calculation r •- -- - -� --- --•- _..... _. __ _ .. �._ w � . 10 Minimum Wire and Conduit Size based on Voltage Drop and Ampacity10 Minimum Ground Size Based on NEC 9.06 A Isc/A' i Number of Strings 10 Actual Ground Size Based on NEC 9.06 A Circuit Amps 24.41 A ' Ampacity After Derate10 Wire Size Based on Ampacity 30 A - 0.5634 % of Voltage Drop 10 Wire Size Based on Voltage Drop" 30 A 24.41 A Minimum Conductor Ampacity Based on Conditions of Use , 14.16 A Minimum Conductor Ampacity Based on 1.56 Rule - - Conditions of Use 0.464 Derate Total M1 68 °C Temp Coef (ambient"+ Sunlight) 154 °F 0.58 1 Derate . . 46 °C Ambient Temp 115 °F' - t .51-3.5" Sunlight Exposure 72 °F 22 6 Number of Current Carrying Conductors 0.8 °C Temp adder Derate applied to Temp Coeficient Voltage Drop: (Allowable Tolerance 1%) ; 37.281V Vmp/Volts - 20 Panels in Series - . 8.46 A Imp/Amps 744.V Circuit Voltage 8.46 A Circuit Amps 20ft One Way Distance = 10 Wire Size 1.241 Resistance 0.5634 % of Loss - Conduit Size (Conduit Fill Can Not be more than 40%) " EMT Conduit Type " .. 0.26 Wire Size Diameter 24.83/o Conduit Fill percentage 1 1/4 ", Conduit Size �.Y ^ , 0.26 Ground Wire Size Diameter r 1.496 lConcluit Internal Diameter - 1000 V System Voltage PV_Wire7 Wire Type , PERMIT# �_� BUTTE COUNTY.DEVELbPMEN EST RVICES r iREVIEWED FOR- E' • oa�C��,>;- �OilLlef�CE ^. . . BY DC Circuit Ampacity Customer Name: KIMURA REAL PROPERTIES, LLC. Location: 95 TOWNSHIP RD., Gridley, CA 95948 Wire Note: DC -1 Description: JUNCTION BOX TO INVETER Wire Calculation Meter #: 1006714411 10 I Minimum Wire and Conduit Size based on Voltage Drop and Ampacity 10 Minimum Ground Size Based on NEC 9.06 A Isc/A Number of Strings 10 Actual Ground Size Based on NEC 9.06 A Circuit Amps 17.26 A Ampacity After Derate 10 Wire Size Based on Ampacity 30�A 0.1127 % of Voltage Drop 10 Wire Size Based on Voltage Drop 30 A 17.26 A Minimum Conductor Ampacity Based on Conditions of Use 14.16 A Minimum Conductor Ampacity Based on 1.56 Rule Conditions of Use 0.656 Derate Total 46 °C Temp Coef (ambient + Sunlight) 46 °C Ambient Temp none Sunlight Exposure 6 Number of Current Carrying Conductors Itage Drop: (Allowable Tolerance 1 37.24 V Vmp/Volts 744.8 V Circuit Voltage 40 ft One Way Distance 115 °F 0.82 Derate 115 °F 32 °F r 0 1°C Temp adder 0.8 Derate applied to Temp Coeficient 20 (Panels in Series 8.46 1 A Imp/Amps 10 Wire Size :onduit Size (Conduit Fill Can Not be more than 40%) EMT Conduit Type 0.26 Wire Size Diameter 1 1/4 " Conduit Size 0.26 Ground Wire Size Diameter 1000 V System Voltage PV -Wire I Wire Type /�/�-0 V� �c;;?i� £;;?J1�T�' I�EVELOEI�IENTSERVICES i�'?,IEVIIEVVE FOR BODE GC i APLIAI CE DAIS /j/ 8 8.46 A Circuit Amps 1.24 Resistance ~0.1127 % of Loss 24,83% lConcluit Fill percentage 1.496 Conduit Internal Diameter AC Circuit Ampacity Calculator Meter #: 1006714411 Customer Name: KIMURA REAL PROPERTIES, LLC. Location: 95 TOWNSHIP RD., Gridley, CA 95948 Wire Note: AC -1 Description: INVERTER TO ACS PANEL Wire Calculation 30 kWatts 480 VAC Delta Voltage Configuration TRUE TL Inverter? 8 Minimum Wire and Conduit Size based on.Voltage Drop and Ampacity '- ' "10 Minimum Ground Size Based on NEC 45.10 A Minimum Ciruit Breaker/Fuse Size Actual Ground Size Based on NEC 45.10 A Ampacity After Derate 8 Wire Size Based on Ampacity. 55 A 0.0585 % of Voltage Drop 8 Wire Size Based on Voltage Drop 55 A 36.083 A Circuit Ampacity 1.732 Factor 3 Phases 0.96 Conditions of Use Derate Factor 37.59 A Minimum Conductor Ampacity Based on Conditions of Use = 45.10 A Minimum Conductor Ampacity Based on 1.25 Rule Conditions of Use 0.96 Derate Total 35 °C Temp Coef (ambient + Sunlight) 95 °F 0.96 Derate 35 °C Ambient Temp 95 °F none Sunlight Exposure 32 °F 0 °C Temp adder 3 or lessi Number of Current Carrying Conductors 1 Derate applied to Temp Coeficient Voltage Drop: Allowable Tolerance (Solar Generation 1%, Distribution 3%) 480 V Circuit Voltage 36.083 A Circuit Amps. 0.778 Resistance 5 ft One Way Distance 8 Wire Size 0.0585 % of Loss Conduit Size (Conduit Fill Can Not be more than 40%) EMT Conduit Type 0.212 1 Wire Size Diameter 175'Conduit Fill percentage 1 Conduit Size - - 0.16 Ground Wire Size Diameter 0.864 Conduit Internal Diameter 600 V System Voltage THWN-27 Wire Type BUTTE COUNTY DEiELOPMENT SERVICES REVIEWED FOR Gdo BY - .. AC Circuit Ampacity Calculator ' - Meter #: 1006714411 Customer Name: KIMURA REAL PROPERTIES, LLC. Location: 95 TOWNSHIP RD., Gridley, CA 95948 Wire Note: AC-2Description: EXISTING SUB PANEL TO FUSED AC DISCONNECT Wire Calculation w - 30 kWatts 480 JVAC Delta Voltage Configuration TRUE TL Inverter? - 6 Minimum Wire and Conduit Size based on Voltage Drop and Ampacity 8 Minimum Ground Size Based on NEC 45.10 A Minimum Ciruit Breaker/Fuse Size Actual Ground Size Based on NEC 45.10 A Ampacity After Derate 6 Wire Size Based on Ampacity 75 A 0.7382 % of Voltage Drop 6 Wire Size Based on Voltage Drop 75 A 36.083 A Circuit Ampacity 1.732 Factor 3 Phases 0.82 Conditions of Use Derate Factor 44.00 A Minimum Conductor Ampacity Based on Conditions of Use 45.10 A Minimum Conductor Ampacity Based on 1.25 Rule Conditions of Use F 0.82 Derate Total , 50 °C Temp Coef (ambient + Sunlight) 122 °F 0.82 Derate Y 50 °C Ambient Temp 122 °F none Sunlight Exposure 32 °F 0 °C Temp adder 3 or lessi Number of Current Carrying Conductors 1 Derate applied to Temp Coeficient ; Voltage Drop: Allowable Tolerance (Solar Generation 1%, Distribution 3%) 480 V Circuit Voltage 36.083 A Circuit Amps 0.491 Resistance y 100 ft One Way Distance 6 Wire Size 0.7382 % of Loss Conduit Size (Conduit Fill Can Not be more than 409/6) RMC Conduit Type _ 0.248 Wire Size Diameter 12% Conduit Fill percentage 1 1/4 Conduit Size 0.212 Ground Wire Size Diameter 26 1.5Conduit Internal Diameter 600 V System Voltage THWN-2 Wire Type - - Blf TC rour�TY DEVELO�Pi1EN SERVICES REVIEWED FOR. ... - DAiE� p 1,� gy - AC Circuit Ampacity Calculator Meter #: 1006714411 Customer Name• KI URA REAL PROPERTIES LLC Location: 95 TOWNSHIP RD., Gridley, CA 95948 Wire Note: AC -3 Description: FUSED AC DIS. TO EXISITING SERVICE PANEL "30 lculation _ _ _ kWatts 480 VAC Delta Voltage ConfigurationTRUE TL Inverter? Minimum Wire and Conduit Size based on Voltage Drop and Ampacity 10 Minimum Ground Size Based on NEC 45.10 A Minimum Ciruit Breaker/Fuse Size 10 Actual Ground Size Based on NEC 45.10 A Ampacity After Derate 8 Wire Size Based on Ampacity 55 A 0.0585 % of Voltage Drop _8 Wire Size Based on Voltage Drop 55 A 36.083 A Circuit Ampacity 1.732 Factor 3 Phases 0.82 Conditions of Use Derate Factor - 44.00 A Minimum Conductor Ampacity Based on Conditions of Use 45.10 A . Minimum Conductor Ampacity Based on 1.25 Rule Conditions of Use 0.82 Derate Total 50 °C Temp Coef (ambient + Sunlight) 122 'F 0.82 Derate 50 °C Ambient Temp 122 'F none Sunlight Exposure 32 °F. 00 °C Temp adder 3 or less Number of Current Carrying Conductors L� _.0 Derate applied to Temp Coefficient - Voltage Drop: Allowable Tolerance (Solar Generation 1%, Distribution 3%) 480 V Circuit Voltage 3.6.083 A Circuit Amps 0.778Resistance 5 ft One Way Distance 8 Wire Size 0.0585 % of Loss Conduit Size (Conduit Fill Can Not be more than 40%) RMC Conduit Type , 0.212 Wire Size Diameter 14% Conduit Fill percentage 1 Conduit Size 0.16 Ground Wire Size Diameter 0.887 lConcluit Internal Diameter 600 V System Voltage _ THWN-2 Wire Type _ OEVE—L&WIENTSERVICES EWED FOR ODE COMPLIANCE OA'i E //-� BY q ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE 2011 I _ REVISION NATIONAL ELECTRIC CODE (NEC), OR LOCAL MUNICIPAL CODE, AND ! PROJECT OWNER: PAGE # CONTENT FIRE DISTRICT REGULATIONS. - 1. , ALL EQUIPMENT SHALL BE LISTED AND LABELED PER RECOGNIZED ELECTRICAL 19. INSTALLATION OF PV PANEL ARRAYS SHOULD RESIST SLIDING AND POP-UP • -TESTING LABORATORY AN INSTALLED PERTH . E LISTING REQUIREMENTS AND THE RESULTING FROM SEISMIC EVENTS AND SHOULD COMPLY WITH CBC SECTION KIM URA REAL PROPERTIES, LLC. (SMALL DRYER) PV -1.0 SCOPE .' MANUFACTURER'S INSTRUCTIONS. 1613A AND ASCE STANDARD 7-05, CHAPTER 13. - I 95 TOWNSHIP RD. PV -2.0 - SITE PLAN 2. ALL INVERTERS SHALL BE IEEE 929 COMPLIANT AND SHALL BE INSPECTED BY LOCAL 20. PV SYSTEM INSTALLER WILL BE RESPONSIBLE FOR FURNISHING AND INSTALLATION j G RI DLEY, CA 95948 PV -2.1 SITE PLAN DETAIL ' UTILITY BEFORE COMMISSIONING, TESTING, AND OPERATION OF THE SYSTEM. OF ALL RELATED EQUIPMENT, CABLES, ADDITIONAL CONDUITS, BOXES WIREWAYS I APN: 021-220-023-000 PH# 530-713-5744 PV -3.0 ARRAY LAYOUT AND OTHER ACCESSORIES NECESSARY FOR COMPLETE AND OPERATIONAL ! , 3. ALL OUTDOOR EQUIPMENT SHALL BE MINIMUM NEMA 3R, INCLUDING OUTDOOR PHOTOVOLTAIC SYSTEMS. I PV -4.0 ELECTRICAL DIAGRAM- - MOUNTED TRANSITION BOXES, COMBINER BOXES, AND SWITCHES. PV SYSTEM CONTRACTOR SHALL COORDINATE ALL THE WORK WITH THE ENGINEER, MAI E PV-4.1 LABEL DIAGRAM CD 0 21. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC - THE CONSTRUCTION MANAGER AND ALL OTHER CONTRACTORS TO ENSURE THAT' ATTACHMENT MODULE SPECS 00 ART.250,690. PV SYSTEM IS INSTALLED AS SPECIFIED IN THESE DRAWINGS. I INVERTER SPECS Ln m w M M N _ CONTRACTOR: 5. NEC. ART. 690.9(A). ALL CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL 22. DRAWING IN GENERAL OR DIAGRAMMATIC AND INDICATE GENERAL + GROUNDING & BONDING rn m m O1 c �, �, m � HAVE OVERCURRENT DEVICES LOCATED SO AS TO PROVIDE OVERCURRENT ARRANGEMENT OF THE EQUIPMENT AND WORK INCLUDED. THE INTENTION OF THE I WIRE CALCS 3 PROTECTION FROM ALL SOURCES. DRAWING IS TO INDICATE SIZE, CAPACITY, APPROXIMATE LOCATION AND GENERAL' I ALTERNATIVE ENERGY SYSTEMS INC. u it o x : RELATIONSHIP, BUT NOT EXACT DETAIL OR PHYSICAL PLACEMENT. {' i • - 13620 HIGHWAY 99 �� ry Z is @1 m = ° a ° 6. NEC ART. 690.18. DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER SHALL DISABLE THE ARRAY DURING 23• / I FIELD VERIFIES EXACT AIC RATING REQUIRED OF THE MAIN SWITCHBOARD FROM kI CHICO, CA 95973_ ,' .`` OV '•I u a u- ._ = ' THEY ARE EXPOSED TO LIGHT, PV CONTRACTOR OPEN CIRCUITING, OR I LOCAL UTILITY. r. #, Ls' �' � INSTALLATION AND SERVICE BY SHORT CIRCUITING, COVERING THE ARRAY WITH AN OPAQUE COVERING. I I CSLB:853351 G10 C-46•. °' • !, • _: ®� - _ 24. A PV SYSTEM WITH MULTIPLE INVERTERS, WHERE INVERTERS ARE REMOTELY I Q�, SCOPE:' y ` BUILDING JURISDICTION: :' E 7. PHOTOVOLTAIC SYSTEM SHALL BACKFEEO THE DISTRIBUTION SYSTEM ON SITE PER LOCATED FROM EACH OTHER, WILL HAVE A DIRECTORY CREATED FOR EACH I I ? ' THE REQUIREMENTS OF NEC ART.690.64(B). ALL BACKFEED BREAKERS SHALL BE LOCATION. AS PER 2011 NEC 690.5(H) AND IN ACCORDANCE WITH 2011 NEC 705.10. t _ _ _ v IDENTIFIED AS SUCH AND SHALL BE SECURED IN PLACE BY ADDITIONAL FASTENER = INSTAL GROUND -MOUNTED_ � ,BUTTE COUNTY `u ' PER THE REQUIREMENTS OF NEC 408.16(F) (408.36 IN 2011 NEC. - I +,' PHOTOVOLTAIC SOLAR SYSTEM AND - ( DEPT. -OF DEVELOPMENT SERVICES . c 8. FALL ARREST PROTECTION PER OSHA REQUIREMENTS SHALL BE PROVIDED FOR ALL - + .1 i UPDATE ELECTRICALEQUIPMENT AS j uj ROOF WORK. ' I ' I ` NEEDED IN ACCORDANCE WITH ALL = 7 COUNTY CENTER DRIVE > m c 9. 'ALL CONDUCTORS AND TERMINATIONS SHALL BE RATED FOR 75-C MINIMUM. APPLICABLE BUILDING CODES' t OROVILLE, CA 95965 SPECIFICALLY REFERENCING THE 2013 OFFICE#: (530) 538-7601 10. NEC ART. 690.14. - SEE SHEET RE -4.3 FOR LABEL DIAGRAM I. CALIFORNIA ELECTRICAL CODE/ 2011 .. FAX#: (530) 538-2140 - i NEC USING THE FOLLOWING SPECIFIC - MON-FRI 8AM-3PM " ' 11. NEC ART. 690.53. -SEE SHEET RE -4.3 FOR LABEL DIAGRAM ' • .. ~ I - I _EQUIPMENT: . INSPECTION LINE: (530) 538-4365 ` 12. NEC ART. 690.17. EACH AC DISCONNECT SHALL ALSO BE LABELED WITH: "WARNING! �, _ _ _ r REQUESTS PHONEDINBY2PMWILLBE " -ELECTRICAL SHOCK HAZARD - DO NOT TOUCH TERMINALS. TERMINALS ON BOTH I MODULES:HANWHAQ-CELL - LINE AND LOAD SIZE MAY BE ENERGIZED IN THE OPEN POSITION". b ' j ZZ " (100) Q.PRO-L-G4-315 INSPECTED THE NEXT BUSINESS DAY Q N rtHMIT# �,• .. 13. DC DISCONNECT ATTHE INVERTER WILL BE READILY ACCESSIBLE AFTER THE BUTTE COUNTY D�E/�VJELOPNIIENTT SERVICES I 31.5kW SYSTEM M INSTALLATION IS COMPLETE PER 2011 NEC ART. 690.17 WHERE TERMINALS OF THE I IU RE EWER FOR 2,053 SQFT COVERED - J `In DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION. PROVIDE A - WARNING SIGN OF THE HAZARDS PER 2011 NEC ART.690.17 V COu� �AIPLIANCE INVERTER(S): SMA - vi = w DAIE BY C> (1) STP3000OTL-US-10 o w' o14" CONTRACTOR TO PROVIDE GROUND FAULT PROTECTION FOR ROOF MOUNTED I a0 v p PHOTOVOLTAIC ARRAYS LOCATED ON DWELLINGS PER 2011 NEC ART.690.17.. w•ww•»wut�.M �+ rn N - Y�Pl ilw+w, wM.tA. 6 15. WHERE MORE THAN ONE NOMINAL VOLTAGE SYSTEM EXIST, THE DIFFERENT '" r , M - tip, '� I s t M aMM�sN�1M M "O"'�' �'INV I" M ' � ,�,��� M M ��' `�" • Lu N U F4, ' Z SYSTEMS SHALL BE IDENTIFIED BY PHASE AND SYSTEM PER 2011 NEC ART.210.4D r} . ® !'w .=t - 16. PROVIDE AN ACCESSIBLE DISCONNECT DEVICE THAT IS LOCKABLE IN OPEN POSITION s .__ _LYS ,c' `y"!n N•MM»M• MMAMM'� 1,� Z AND IS LOCATED WITHIN 10'-0" OF THE METER PER LOCAL ELECTRICAL UTILITY r tr... �.+,+':• - c.��ci - - i1 �„ ' i . tM••MM'M•M�M• nMMM.•tt♦ � .ww..M.+•...••,p�y:_w• • y�1t -.q••rNY••• r t+ Vl Y m 0 Q 'REGULATIONS. BUTTE iiia ,'j'.yt _ _ '" �� w.i ww:�iw : '�,i t •�� M�!N• • i •�•••.aw�wa. �• SCALE ' . N.T.S. y C COUNTY ;��: ♦ti: DATE MODIFIED 17. PHOTOVOLTAIC SOURCE CURRENTS MUST BE RATED AT BOTH 125% OF THE i,M?�" �y r'••--�.T� 01/28/2016 PARALLEL MODULE AND AT A CONTINUOUS LOAD OF ANOTHER 125% FOR A TOTAL . MAR p 3 2016 •� i .. ! �- i•;; r ! - -. ��� _ ' S I ; . a • `� a. C{� DATE CREATED OF 156% OF THE LOAD. w� �' 1 • 4 L' DESIGNER/09/2014 i• - •• - DEVELOPMENT '�' k s '® r "�-�; .. ,.,,,t i '' E. TRITTEN CONSULTANT: - , 18.' PROVIDE PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF THE SERVICES �•,�: `.`' . ✓a �"'• c,. •; :. --° aauul +j , R_ SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECT _ SHEET MEANS IF THEY ARE NOT IN THE SAME LOCATION PER 2011 NEC ART.690.56. 1 )Q it �. A F• t..�+ 'i � c PV -1.0 _ - ' GENERAL NOTES .2 i SITE MAP 1 SCOPE ` •�a -- �-- r 26481„ _ f Remove vegetation acid debris from under and away from structure.. Maintain clearance for a fire safe environment. KEEP O.AUFORNIA GREEN 4 , Flood Zone; 3 . (E)PLUM ORCHARD F SEE PV'2 ,1t _ x FOROETAILS'' -- (E) GULLY----- —^a \ t 95 TOWNSHIR RDS 4 �Vt � � � ire GRIDLEY CA,,9594&. �\;`� 182' _ \` J BUTFE COURTN' \.-� • -77- PARCEL#021k220=023-000` (E)PLUM ORCHARD - '(E)PLUM'ORCHARDI Ir Ir i ,f ---x. G . t } I' • . 22:92" (E)BLDG (E)BARNI Al I I,oY2Z t � -• ' `_ � �;d I. • I :'r a •.v " �� � ` _. c : a i. l I'-.. C31;1 � : ' J^' • y e lt' r -L PkfENT'SC` (E)PLUM ORCHARD (E)PL'W' 'ORCH'ARD1.',} PI I' � 1 ,.. I I II ii 4 f.. t' V O� r" E WMPLIA DI'-z-b`�1 �6 By0. -- -- 1 I r ] » • 0' 60" 100" 200' 500' i •: - ° , ' !:F II Y H 261'4". � A, � r tEVISION 4 •. • i E4 c r 0, " 0CD 0 r 01 0 t0 t0 Ln m w cf N ? in p o°io c . M rnv,^a Q m ro OW u1 = 0 X 0 4 Y' v0.LL ter,% L • } e t�11 's Y • f «;' Iv a W m L .. w J J Z rn CD 'C, o• L ."0 C CC01 N L Ln q J v. CI) o. - -�4 J to U N y Z } OJ Z CC a e rn LD Q ' ALE , V=300' 4TE MODIFIED 01/28/2016 _ - 4TECREATED - 10/09/2014 ' ESIGNER: E. TRITTEN 'If, )NSULTANT: - { RICH & AMBER ' IEET PV 2.0 ` SITE PLAN. . , rf ' •-*==r-^'--- ..- ..--� - _ _. ems- - — _ - . _ - -- .__ ^_. _ _..- _. _ —. _.__. _. - ..r.�,, -- • - f � ' „ F 1 �- t � REVISION _ e * d t `,(E)PLUM ORCHARD u (E)METAL BUILDING E `95,T0WNSHlRRDt a — — — — — — — — — c)Oo �� GRIDLEY„ CA 95948 — -- - - �o r - - BUTiTE C0UNTiY _ ' - ti , # -�t �, ra a i °I, M m N ^ PARCEL#,021=2'20=023-000 •, 4 " � r ( s ` (E)ARRAY ~` 2 a { _ : f rn m � c v YL'J - Y, 1 .''! " �� �. .,, O t�.. i V,-{ w • '1.w i .. `�. .� ;.i = U W v1 O O NO Z st tN0 O X O.L t•e (E)AG EQUIPMENT y@ 'I I - _ _ •F _ �I ... f-'� '''1 t` ,tom "(E)METAL BUILDING W/ �Y '�. ". W N METAL PULINS Ol t a fi mf2h_ t • + t - w 01 — > �t� •? a (. .. E.t i✓ - -�, .-y I `� .71 ,1 ORE O + i 101 Q M vii F, 411..1,' �7'� 4 J L A J / L : �. PEI ((kii Ic F E3 �. vi _ BU7TF CJUfiiY1i G°hgEt�1TSEFtNI'CES� `.' a REVIEWE' O`_ DO 9 rI 0 a06 ml C, ,.� r^` • ti ti `y (E)DRYER �� f DA••E �� LJ y jt o '( w ='a o ' •i+ I UJ �:: •. - . ''._. ------ ---h 27.31. I , o Z.0 o _ I SCALE F� 3 ¢ •�,. . (N) FUSED AC DISC .: +,.� . � �-� � _ 1"-30' r _ EXTERICIR'WALL'. i-------- L�. DATE MODIFIED01/28/ 016 •sir'+"- -F 'I -art "W <'DATE CREATED a IE SERVIC PANEL - µ} DESIGNER/09/2014 `�"'\, ). ` - ' i� E. TRITTEN' • a'• 600A/3013W/480VAC—.(E)RESTROOMS s� - CONSULTANT: a....—. P.■I �A t RICH & AMBER + ...r -y''�' .''•�.` t. 1 - i a.,•, 4,.. i SHEET • 1 3 P ,� v4 a , 'a3--�Fr''t :� i���...� � r`''� V .- _.._..,.•k.,.......�.x...-..-e ��•�► � �;_ rs.,r� _ , .. - r..� f , �`4 j - k- SITE PLAN t Imo` DETAIL REVISION NOTES STRING"LABEL KEY 1.ALL ROOF PENETRATIONS A 1 RINJTO BE 60" O.C. MAXIMUM INLV�EBEL R MPPLLA EL Coo°00 ��' 113' k E C) u 0 w °' o PER ARRAY ROW £ - - ' 'A ARRAY FLUSH - ------------------------- ------------ -- MOUNT W 0 , - I 3 N. --------------------------------- - -- v -' - - - - - - - - - - - - - - 4' SET BACK FROM I a GABLES AND RIDGE r� 104.4' i PER CA FIRE CODE - 01, TRINGING .LAYOUT J. 16"=1'-0" PERMIT# BUTTE CQUNTY REVELOPMENT SERVICES Q m ARRAY TO BE m c 4' TILTED TO 50 REVIEWED AOR � m - SEE DETAIL 2 CODE �� PLIANCf `" B %�• a W = DK E�-_ _ a — — — — — — — — — — — — — — — — — — — — — — — — — — -- O o �� -- ----= = - = --- =-= =- == -- = =- ~ • o o o. 0 rq 16.5' _ . . Q = I UN Q N. , - l UJI o -- -- - - - -- -- - -Xi - -- -- - -- I o i`-- 3.3' w o o z Ln w a —� ' -- -- _ -_ -- - -- - - -- -- - - -- -- - - -- - - - - -- '- _ SCALE AS SHOWN _ _ _ _ _ DIFIED TILT MODULES 1.5X1.5 AL SQUARE DATE MD/28/2 Ol/TE/2016 — — — — — — — — — — — — — — — — — — — — . � _ DATE CREATED 101.4'; 4' 5° FROM LEVEL TUBING FOR TILT LEGS 10/09/2014 DESIGNER: ' E. TRITTEN d . 1 CONSULTANT: RICH & AMBER SHEET TILT UP DETAIL 5/16"=1'-O" n ARRAY LAYOUT RACKING LAYOUT 1 1"=20'-0" �n m w • V N > - n Cn `0 (( PV Ol a1 o f0 ' = U YC U1 O 4-1 • -. (E)PULIN SPACING o ° Z it a@ 5' ON'CENTER r `m X: <. o a.a. s ------------------------------------------------------- - - r-----------------.------------------ -i-- (3) EJOT STAND-OFFS ,. ro J Y�' PER ARRAY ROW £ - - ' 'A ARRAY FLUSH - ------------------------- ------------ -- MOUNT W 0 , - I 3 N. --------------------------------- - -- v -' - - - - - - - - - - - - - - 4' SET BACK FROM I a GABLES AND RIDGE r� 104.4' i PER CA FIRE CODE - 01, TRINGING .LAYOUT J. 16"=1'-0" PERMIT# BUTTE CQUNTY REVELOPMENT SERVICES Q m ARRAY TO BE m c 4' TILTED TO 50 REVIEWED AOR � m - SEE DETAIL 2 CODE �� PLIANCf `" B %�• a W = DK E�-_ _ a — — — — — — — — — — — — — — — — — — — — — — — — — — -- O o �� -- ----= = - = --- =-= =- == -- = =- ~ • o o o. 0 rq 16.5' _ . . Q = I UN Q N. , - l UJI o -- -- - - - -- -- - -Xi - -- -- - -- I o i`-- 3.3' w o o z Ln w a —� ' -- -- _ -_ -- - -- - - -- -- - - -- -- - - -- - - - - -- '- _ SCALE AS SHOWN _ _ _ _ _ DIFIED TILT MODULES 1.5X1.5 AL SQUARE DATE MD/28/2 Ol/TE/2016 — — — — — — — — — — — — — — — — — — — — . � _ DATE CREATED 101.4'; 4' 5° FROM LEVEL TUBING FOR TILT LEGS 10/09/2014 DESIGNER: ' E. TRITTEN d . 1 CONSULTANT: RICH & AMBER SHEET TILT UP DETAIL 5/16"=1'-O" n ARRAY LAYOUT RACKING LAYOUT 1 1"=20'-0" DC -1 DC -2 AC -1 AC -2 AC -3 SERVICE VOLTAGE REVISION (2) 1-1/4" EMT EACH w/ (2) 1-1/4" EMT EACH w/ (1) 1" EMT w/ (1) 1-1/4"" PVC w/ (1) 1" RMC w/ NAV=N-Ll-L =4 V - — — — — — — — -- — — — — — — (6) #10 2KV PV WIRE CU. & (6) #10 2KV PV WIRE CU. & (3) #8 THWN-2 CU. & (3) #6 THWN-2 CU. & (3) #8 THWN-2 CU. & NAV=N-L2-L3=480V I I (1) #10 THWN-2 CU. GRD. (1) #10 THWN-2 CU. GRD. (1) #10 THWN-2 CU. GRD. (1) #8 THWN-2 CU. GRD. (1) #10 THWN-2 CU. GRD. NAV=N-L3-L1=480V I 2 I WIRE RUN: 200' WIRE RUN: 40' WIRE RUN: 5' WIRE RUN: 100' WIRE RUN: S' I I IMP: 24A IMP: 17A I MAX: 45A IMAX: 45A IMAX: 45A I 3 I • - 1- . I 20 1__ - METER (100) PV MODULES 1 JUNCTION INVERTER "C" _ AC -DISC - o HANWHA Q -CELL/ Q.PRO-LOG4-3151 gOX 30KW GRID TIED INVERTER 45A FAST ACTING FUSES 0 ai 00 (5)STRINGS OF (20) 36A/ 3P/ 480VACCOOPER BUSSMANN: KWS-R-45 � o 1000VDC I SMA: STP30000TL-US-10+ 60A/ 3P/ 600VAC N �_______________i W/INTEGRATED DC DISC. CUTLER HAMMER/ r o SERIAL #: i 01 in 00 r - } 0, a ,n a Q 'o {• =u vo w - t 1 .n O ZO �O ---_ __- -- _ --� 600A tO0 x MD c AC -MONITORING i COMPLY WTfl2013 CALJF0RVL4 3P (1) 3/4" EMT w/ ELECTRICAL CODE- AR77CLE690.10(E) a 480V v (2) #12 THWN-2 Cu. & 408.36(D) and 705.12(D)(6) REQUIREMENTS (1) #12 THWN-2 CU. GRD. FOR Uti/ily�irGeiconnected Elecbic Power o 0 `� E • WIRE RUN: 5' 45A :: IMAX: 20A 3 Production Systemv " ' 480 i w r CAT -5 .. , - ❑❑❑ ____�_____ MONITORING 1 - „ c U W z _ BOX v 277 . - r i SIERRA .. ; - • WIRELESS: 3G MODEM SMA: SUNNY ar + - • C wee sox - 45 a ,. (N)AC DISTRIBUTION PANEL 3 a 10OA/ 3P/ 480VAC ' 480 (E) AC SERVICE PANEL 60OA/ 3P/ 3W/ 480V' r o v - '.SCIR:35,000 METER#: 1006714411 Q � � n Li C) M J LnJ N = — w a COMPLY WITH 2013 CAL¢ORNIA. OC a o O Ci m ELECTRICAL" CODE- AR77CLE 705 a Cn o - REQUIREMENTS FOR Interconnected PLY,WITH J a � o , _ CAL/PORN/A Electric Power Production Systems '' TR/CAL.CODE- [REQ � < N Ln IREMENTS'F AR.T/CLE 690 � wOR SOLAR OOVOLTAIC SYSTEMS ita - SCALE '--'•-`-^J N.T.S. DATE MODIFIED 01/28/2016 CALIFORNIA ELECTRICAL PLY WITH &4,oYLL DATE CREATED 10/09/2014 - E for wiring methods- Secure I�LHNIIa � DESIGNER: E. TRITTEN uctors and conduit per all applicable BUTTE COUNTY DEVELOPMENT SERVICES rr:equiremerds CONSULTANT: - as required by the 2013 CEC for I ®� / D FOR V RICH & AMBER SHEET pecfic method of wiring --F CONAP LIQ _ CODE _ (�� PV -4.0 ` ELECTRICAL SINGLE LINE •♦ f . L • - - . .' _ , _ -• • REVISION - • PV ARRAY _ -� COMBINER t INVERTER • - ' ',(•• r AC DISCONNECT _ - MAIN SERVICE • r - • s.' -i - . • _ ____ -» SUB PANEL * � . . f •` • , -METER 5 - ams aas • - � '' , y - + ER i� - - _ .. - � - - !' . �• - � � - Y_ 00 (1) 1 - tt_ CD a • t. .. ` e _ 4 a -AMPS { _ PHASE`01 - y • •• • r .t • a Q1 m C . VOLTS N lJ Z YL • ' v til t f.1. . r `• - - 5 .j '�, •. • owtSE _ '. lJ = Q Q 0' ' en Le WARNING I „ '-� • ' ` Y . s f _ . _ s per•. r.' ' , 'f - • D 4 N- .d• UTILITY INTERACTIVE POWER FLOWING THROUGH THIS PANEL C UA CAUTION: SOLAR CIRCUIT KW SOLAR GENE6�OR L AC OPERATING VOL Installed on all DC -conduit every 10' and. • ` ° + , .WARNINGVAC/ PHASE j' r . on both sides of any penetration.,•DC • • • •SUPPLY a 4 LOCATED PHOTOVOLTAIC SYSTEM •.-�'• r -Per NEC 690.54 Interactive'Point of ''� •' .:. '' f Per NEC 705.10, Point of Connection, Located o v SOLAR Interconnection installed at aII Electrical -� - — ^ 'Ln • A • • • • Distribution Panel covers that provide a path On Main Service Panel _ o a • • • • _ from PV to Utility. {� , _ N • ^• 0 Ln ~t .i Installed on all DC Junction boxes. •PHOTOVOLTAICV, . DISCONNECT cc 0 SHORT CIRCUIT CURRENT: A LU OPERATING VOLTAGE: -'i-VDC OPERATION r4 WARNING! MAX SYSTEM VOLTAGE: VDC 0), 6 ELECTRIC SHOCK HAZARD WARNING SHOCK HAZARD! cc•THE DC •• • •F THIS • • • • • •• • I r - `, ' Per NEC 690.14,:Dis`connection means at the ? o J o, �t • -� a single AC Disconnect or Main Breaker. g z s • Ln a BE ENERG;IZED'IN OPEN y*AND MAY BE ENERGIZED LOAD SIDE MAY. - SOLAR - SCALE Per NEC 690.35 F Warning shock hazard at. -Per NEC 690.14, Solar. Disconnect on the • •RELOCATE` +• I p DATE MODIFIED N.T.S.N. ), v , _ ♦ ! •..�..+ 01/28/2016 front of all PV DC Disconnects.`F.Illed out in - Solar breaker label @any breaker passing DATE CREATED each junction'box, combiner box or other device 10/09/2014 •. opened during service._ = - - accordance with NEC 690.55•. a Bi -Directional Power , ' • r DESIGNEE. TRITTEN :a: ,B ` " •- � - • a CONSULTANT: • - , . . �.- _ t�. r• y r y VYY. - RICH&AMBER PERMIT tr•' ���„---- y. • t ` t ,' s ' j3OT`rE LOUNTY D JELOPIVIENT SERVICES SHEET PVA 1, ;..t. L — )'• LABELING •s a ;}; y • r r �� /�IV_ p`-- (kyr/ DIAGRAM