OENERAL. NOTES G-1 MISCELLANEOUS I. PROVIDE 4" HIGH x �" WIDE STREET ADDRESS NUMBERS OF CONTRASTING COLOR, VISIBLE FROM STREETS. 2. FIRE SPRINKLER SYSTEM 15 REQUIRED PER CRC R313.3 OR NFPA 13D. FIRE SPRINKLER PLANS SHALL BE SUBMITTED UNDER SEPARATE COVER; SUCH PLANS MUST BE APPROVED, PERMIT ISSUED, AND HAVE INSPECTION BY THE FIRE MARSHALL PRIOR TO BUILDING CLOSING IN. CONCRETE I. CONCRETE TO BE 5 SACK MIX, 2500 P51 ® 28 DAYS 2. RE I NFORC I NO STEEL TO BE I NTERMED I ATE GRADE DEFORMED BARS -TYPE N OR 40. ROUGH CARPENTRY 1. INSTALL BLOCKING AS REQUIRED TO SUPPORT FINISH HARDWARE AND FIRE STOPPING TO OUT OFF CONGEALED DRAFT OPENINGS AS REQUIRED BY CODES. 2. STRUCTURAL FRAMING SHALL BE DOUGLAS FIR TO THE GRADES INDICATED OR BETTER (HHPA GRADING RULES) UNLESS NOTED OTHERWISE. CONGEALED 4x BEAMS 4 POSTS ......................... NO. 2 EXPOSED 4x BEAMS 4 POSTS...............................NO. I (ox BMS $ POSTS.........................................................NO. I 2x JOISTS AND RAFTERS........................................NO. 2 STUD, 51LL5, PLATES...................................................NO. 2 SILLS ON CONCRETE...................................................PTHF MISC. FRAMING NOT NOTED....................................NO. 2 3. PLYWOOD SHALL BE OF THE DESIGNATED GRADE AND SHALL MEET THE REQUIREMENTS OF THE U.S. PRODUCT STANDARDS PS I-83. 4. NAILS AT PLYWOOD PANELS SHALL HAVE 5/6" EDGE DISTANCE AND SHALL NOT PENETRATE FACE -PLY. 5. NO PIECE OF PLYWOOD ROOF, FLOOR OR HALL SHEATHING SHALL BE LESS THAN 12" IN LEAST DIRECTION. 6. FRAMING HARDWARE SHALL BE 51MP50N STRONG -TIE OR APPROVED EQUAL, WITH CONNECTORS AS SPECIFIED 7. PROVIDE SOLID BEARING CONTINUOUS FROM ALL BEAMS TO FOUNDATION. 8. PROVIDE FIRE BLOCKING IN CONGEALED SPACES VERTICALLY AND HORIZONTALLY IN ACCORDANCE w/ 2013 G.R.G. SECTION 8302.11. 9. FASTENERS FOR PRESERVATIVE TREATED AND FIRE TREATED WOOD SHALL BE OF HOT DIPPED ZING COATED GALVANIZED STEEL, 51LICON BRONZE OR COPPER. THE GOATINO HEIGHTS FOR ZING COATED FASTENERS SHALL BE IN ACCORDANCE w/ ASTMA 153. 2013 G.R.G. SECTION R317.3. 10. BEARING WALL HDR5. SHALL BE 4x10 #2 OR 6x8 D.F. #1 MIN., TYP., U.O.N. 11. EACH SIDE OF TOP PL. LAP SPLICE SHALL HAVE (8) Ibd (5�" x .135"(P) MIN., TYP. OI I IM=I Alr I. THE AGGREGATE AREA OF PLUMBING VENTS SHALL BE 12.57 50. INCHES, MIN. 2. GAS FIRED WATER HEATER TANKS SHALL BE FASTENED TO THE ADJACENT FRAMING w/ 16 GAUGE METAL STRAP (0516 OR EG.) w/ MIN. 2" LONG #12 HOOD 5CREH5 ® 4" ABOVE CONTROLS AND WITHIN 12" OF THE TOP OF THE TANK. 4. SHOWER AND TUB -SHOWER COMBINATIONS SHALL BE PROVIDED w/ INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE THERMOSTATIC MIXING VALVE TYPE. 5. INSTALL A 4" DRAIN FOR BUILDINGS PROVIDING MORE THAN (3) HATER CLOSETS. 6. HORIZONTAL DRAINAGE PIPING SHALL BE 2% MIN. SLOPE. 7. 5HOHER AND TUB/SHHB WALLS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE o/ A MOISTURE RESISTANT UNDERLAYMENT TO A HEIGHT OF 72" ABV. FINISH FLR. DRAIN INLET, PER GRG R307.2 8. A NON -REMOVABLE BACKFLOW PREVENTION DEVICE SHALL BE INSTALLED ON ALL EXTERIOR HOSE BIBS. 9. THE HATER HEATER'S TYPE 'B' GAS VENT SHALL TERMINATE NOT LF -55 THAN 5' IN VERTICAL HEIGHT ABOVE THE HIOHE5T CONNECTED APPLIANCE DRAFT HOOD OR FLUE COLLAR. MECHANICAL I. DRYER DUCT TO BE MIN. 4" (P TO THE OUTSIDE, EQUIPPED WITH A BACK -DRAFT DAMPER. 4"(P DUCT LENGTH 15 LIMITED TO 14' WITH 2 ELBOWS. OTHER LENGTHS OR SIZES AS PERMITTED OR REOUIRED BY THE MANUFACTURE'S INSTALLATION INSTRUCTIONS MUST BE APPROVED BY BUILDING OFFICIAL. (SUBMIT REQUEST FOR MODIFICATIONS.) 2. 51NOLE-WALL METAL PIPE SHALL NOT BE USED AS A VENT IN DWELLINGS AND RESIDENTIAL OCCUPANCIES. SHEARNALL 50HEDULE : SYMBOL: SHEARWALL: Q6 5/e" GDX PLYWD. OR OSB w/ 8d'S ® 6", 12" O.G., 16d I5t FLOOR L I V I NO AREA: SINKER SILL NAILS ® 8" O.G. QQ. g/8" GDX PLYWD. OR OSB w/ 8d'5 ® 4", 12" O.G., w/ OARAOE AREA: 4x STUDS ® ADJ. PANEL OOVERED FOROH AREA: SPLICES, Ibd SINKER SILL NAILS ® 5)'2" O.0 MINIMUM T 1 TLE 24 REQU I REMENT5: 5/8" GDX PLYWD. OR 055 MINIMUM HEA71NO EFFIOIENOY: W 8d'5 ® 5"'12" O.G. w/ 2L 4x 57UDS ® ADJ. PANEL DUCT INSULATION: SPLICES, Ibd SINKER SILL RAD I ANT BARRIER ROOF SHEATH I NO: NAILS ® 4Y2" O.G. WATER HEATER EFF 1 O 1 ENOY: 5/8" GDX PLYWD. OR 055 2Q w/ 8d'S ®2", 12" O.G. w/ -DUOT LEAKAOE VERIFICATION 4x STUDS ® ADJ. PANEL -HVAC: VERIFY AIRFLOW (550) SPLICES, 16d SINKER SILL 00 NAILS ® 2y2" O.G. I. NAILS SHALL BE COMMON NAILS (2Y2"x.131'), TYP., U.O.N. 2. ALL PLYWOOD PANELS SHALL HAVE ALL EDGES BLOCKED. I RECEIVED AUG 2 4 2016 TRB AND ASSOCIATES NATER NEATER MANDATORY FEATURF-S WATER HEATING SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE THE FOLLOHINO COMPONENTS: I. A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATER HEATER AND ACCESSIBLE TO THE HATER HEATER WITH NO OBSTRUCTIONS 2. A CATEGORY I I I OR IV VENT, OR A TYPE B VENT WITH 5TRAIOHT PIPE BETWEEN THE OUTSIDE TERMINATION AND THE SPACE WHERE THE WATER HEATER 15 INSTALLED 3. A CONDENSATE DRAIN THAT 15 NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP A5515TANCE 4. A OAS SUPPLY LINE WITH A CAPACITY OF AT LEAST 200,000 BTU/HR. FEMA REQUIREMENTS I. A BUILDING UNDER CONSTRUCTION FLOOD ELEVATION CERTIFICATE 15 REOUIRED PRIOR TO THE FRAME INSPECTION AND A FINISHED CONSTRUCTION FLOOD ELEVATION CERTIFICATE 15 REQUIRED PRIOR TO FINAL APPROVAL OF THE STRUCTURE. (BUTTE COUNTY CODE CHAPTER 26, ORDINANCE # 4041) 2. BASE FLOOR ELEV: 222.60' MIN. HOUSE F.F.: 223.60' MIN. GARAGE 5TEMHALL HT.: 222.60' MIN. MECHANICAL UNITS F.F.: 223.60' 3. HOUSE FLOOD VENTILATION: 2554/144 = 17.74 50. FT. OF NET FREE AREA. PROVIDE (12) I5"x24" CRAHL SPACE VENTS ® 1.6 50. FT. EACH. TOTAL FLOOD VENTING AREA PROVIDED 19.2 50. FT. 3. GARAGE FLOOD VENTILATION: 1026/144 = 7.13 502. FT. OF NET FREE AREA. PROVIDE (9) I6"x8" FLOOD VENTS ® .86 502. FT. EACH. TOTAL FLOOD VENTING AREA PROVIDED 7.74 50. FT. CODE ANALYSIS GOVERNING CODES: 2013 GBG, 2013 GRG 2013 CEG, 2013 GPO, 2013 CMG, 2013 CFC, 2013 CALIF. HEALTH 4 SAFETY CODE AMENDMENTS 2013 CALIF. ENERGY CODE EFFICIENCY STANDARDS, ZONE II 2013 CALIF. ACCESSIBILITY REG2UIREMENTS AMERICANS w/ DISABILITIES ACT, 2012 EDITION NFPA 101, 2013 CGBSG OCCUPANCY GROUP: GROUP: R3 / U ALLOWABLE HEIGHT AND BUILDING AREAS (TABLE 503) ALLOWABLE AREA: UNLIMITED ACTUAL FLOOR AREA: 4505 S.F. ALLOWABLE STORY/HEIGHT: (3) STORIES / 40'-0" ACTUAL STORY/HEIGHT: (2) STORY / 26'-6" CONSTRUCTION TYPE: TYPE VB AUTOMATIC SPRINKLER: REWIRED WILDLAND URBAN FIRE INTERFACE: N/A DEFERRED SUBM 1 TIAL : FROFANE TANK ANOHORAO E REVIEWED V PERMIT # 1 ' C✓ ! �2 FOR CODE COMPLIANCE BUTTE COUNTY DEVELOPMENT SERVICES MUG 2 6 20 IS REVIEWED FOR CODE COMPLIANCE LII,ANCE DATE (& ,/ (f! - i 11/ BY T B AND ASSOCIATE AREAS: Date: I5t FLOOR L I V I NO AREA: 2552 5Q. FT. UF5TAIR5 UNHEATED 5T0RA0E AREA: -156 SQ. FT. OARAOE AREA: I OI cl 5Q. FT. OOVERED FOROH AREA: a54 5Q. FT. MINIMUM T 1 TLE 24 REQU I REMENT5: MINIMUM HEA71NO EFFIOIENOY: a5% AFUE MINIMUM OOOLI NO EFFIOIENOY: 14.0 SEER I I. -I EER DUCT INSULATION: R8 RAD I ANT BARRIER ROOF SHEATH I NO: REQ'D WATER HEATER EFF 1 O 1 ENOY: 82 REQU I RED HERS VERIFICATION: -DUOT LEAKAOE VERIFICATION -HVAC: VERIFY AIRFLOW (550) VERIFY FAN WATT DRAW -IAQ FAN: VERIFY 52.54 OFM Revision: Date: By: r H 4 00 � U � d a w r) V O � o ' y ao M W W V1 H Q Q � O F-+-1 W W 0 AA.CA��F FSA * No. 1283 RE 7/17 DREWS 2552 Date MARCH 2016 Scale Drawn 05TR0\/5KIY Job 15-2056 Sheet Of SEVEN Sheets �_ r--- I L'L (0 F>Y- m ATTIO STO AOA. 1/4" = 1'-0" I F07M �mm owl REAR ELEVATION 1/4" = I' -o" FRONT ELEVATION GEMENT 5D. LAP 51DINO o/ (2) LAYERS OF 15# FELT., TYP. PERMIT# R.EVIEVIELI BUTTE COUNTY REVIEWED FOR sERvlces FOR CODE COMPLIAN CF (CODE COMPLIANCE DATE V fJ. AUG 2 6 BY .JR5 AND ASSOCIATES Revision: (Date: I By: N =ry D t rt `r W ip 3068 E-� 2668 ++ (ATTIC //�� ST O RAOE CCF -55) MSI U o n o u u O — rT-1 Q LO � � o o W W0 — _ L 3 W s� 22"x30" ATTIC W t AGGE55 M m N N 2020 2020 FIX FIX 01 26-0" ATTIO STO AOA. 1/4" = 1'-0" I F07M �mm owl REAR ELEVATION 1/4" = I' -o" FRONT ELEVATION GEMENT 5D. LAP 51DINO o/ (2) LAYERS OF 15# FELT., TYP. PERMIT# R.EVIEVIELI BUTTE COUNTY REVIEWED FOR sERvlces FOR CODE COMPLIAN CF (CODE COMPLIANCE DATE V fJ. AUG 2 6 BY .JR5 AND ASSOCIATES Revision: (Date: I By: N W W E-� M ++ MSI U o o u u O Q LO � � o o W W0 W s� W ao M W W Q o O Q LO � 0 O �O4-1� W W SGORY RC� * No. 1283 NJ� REN 7/17 � DREWS 2552 Date MARCH 2016 Scale Drawn 05TR0\/5iG I Y Job 15-2056 Sheet 2a M M Of Sheets SEVEN o N N N SHEARPLY, 51 FLOOR PLAN R-51 f SLID BLKC. 35 a 4'-0" O.G., YP., U.O.N. SHEAR TRANSFER STOM LOOK LAP STRAP TO BOTTOM CHORD OF DRAG TRU55 $ TOP FL. 20" MIN. w/ (25) 16d'S SINKERS 8d'S ® 6" O.G. TO TRU55 BLOCK I NC TOP CHORD OF TRU55 BLKC . TRU557 TRUSS vz NAIL 6'-0" LONG (I) CONT. 2x6 TO BOTTOM CMSTCI6 CHORD OF DRAG STRAPS W TRUSS w/ 8d'5 (9 12" 8d'5 a 2" O.G.5TACCERED O.G. (48 TOTAL NAILS) SHEAR TRANSFER GEMENT BD. LAP SIDING o/ (2) LAYERS OF 15# FELT., TYP.- 14"x24" C.E. /ENT, TYP. LEFT ELEVATION 1/4" =1'-0" RI (5HT ELEVATION 11411 = I PERMIT # v) `0 - DSq 3 BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE REVIEWED FOR CODE COMPLIAI`,Ir E AUG 26 266 TRB AND ASSOCIATF. Revision: (Date: I By: N N z W H M a U `� ++ r ,a � O Cd a� ;= o0 O >= Lo CT F+� o w W ' ` M W z W H H � � O O (D Lo CT w W W W AR( No. x271i 3 REN7 DREWS 2552 Date MARCH 2016 Scale Drawn OSTR01/5K1 Y Job 15-2056 Sheet 3 Of 5E\/EN Sheets _a 7 co M T -i M it O ri O N N N 0�0 Y. A55 a 4'-0" ROOF PL O.G., TYP., U.O.N. 50LID BLOCKINO—ter 5HEARPLY, SEE PLAN SAVE DETAIL R_I III = FASCIA, SEE ELEVATION 51DINO G.E. TRU55 5HEARPLY, SEE PLAN - E.N. E.N. E.N. R-12 F.A.U. lYa" x lYa" ANGLE N/ NUTS AND WASHER, TYP.— E.N. OF PLY A55 © 4'-0" O.G., TYP., U.O.N. GABLE F—ND a/8" DIA. THREADED ROD IVa" x Va" ANGLE W (2) Y4" x 2" LONG LAG BOLTS INTO TOP CHORD OF TRU55, TYP. 4So SEISMIC RESTRAINTS (4) DIRECTIONS F.A.U. MOUNT I NO rol ICG hl d I I onnt= PI Y Tn TnP TRUSS_ STRAF —ROOF PLY =.N. DRAG TRU55 SEE ROOF PLAN FOR A55 SPACING 4 LOCATIONS E.N. 5HEARPLY, SEE PLAN ® 16" O.G. z DRAO TRUSS 12 ROOF 6 TRUSS III \- HANGER III ,I I C I RDER TRUSS r5"'�NTRU55 END DETAIL L�. CUSTOM SOLID BLOCKING TRUSS �ml CUSTOM I' -O" 2x4 STRUT TO RAFTER BELOW IS 4'-0" O.G., TYP. EA. too RAFTER x6 MIN. ® 4'-0" O.G. BU I LD I NO S�=GTI ON 5-4 1/4" RIDGE 2x6 RAFTERS 2x5 FLAT W/ (2) I&d PER RAFTER BELOW CALIF. FILL DETAIL R-20 1/2" = 1'-0 C-� SECT I Oil A4 1/4" = i' -o" ROOF NOTF5: I. ROOF FRAMING SHALL BE: PRE -MFR TRUSSES ® 24" O.G. TYf'. U.O.N.. HAND FRAMING 2x6 RAFTERS ® 2'-0" O.G. w/ 2x5 HIPS, VALLEYS $ RIDGE5 WHERE INDICATED ON PLAN. 2. ROOF PITCH SHALL BE: VARIES, 5EE PLAN 5. ROOF O.H. SHALL BE: 1'-0" ® ALL G.E. 1'-O" a 6:12 PITCH I'-0" ® 10:12 PITCH 1'-0" ® 10:12 PITCH 4. ROOF COVERING SHALL BE: COMP. 5HINOLF-5 o/ 15# FELT o/ Y2" CDX OR 055. w/ Sd'5 ® (b,"12" O.G. 5. REQUIRED ATTIC VENTILATION: 4505 / 500 = 15.02 50. FT. OF NET FREE AREA VENTILATION REQUIRED. • LOW VENTING: PROVIDE (25) 5Y2"x225/a" EAVE VENTS ® .55 50. FT. EACH. TOTAL LOW VENTING PROVIDED: 7.51 50. FT. OF NET FREE AREA • HI5H VENTING: PROVIDE 61' CONT. RIDGE VENT a 0.125 50. FT. PER FT. TOTAL HIGH VENTING PROVIDED: 1.625 50. FT. OF NET FREE AREA. 6. ATTIC MOUNTED F.A.U. PROVIDE SERVICE LIGHT W 5WITGH ® AGGE55 HOLE. PROVIDE IIOV SERVICE OUTLET ® UNIT. PROVIDE 24" WIDE CATWALK FROM AGGE55 HOLE TO 50" 50. x 50" H15H CLEAR MAINTENANCE PLATFORM ® UNIT. PEnMIT 0 ES -- BUTTE COUNTY Af VEL®PMENT rt iVl� R IEINED F CODE COMPLIANCE DAT Z / BY 2x6 CALIF. FRAMING ® 24" O.G., T`(P. PER -r HAND FRAMED ROOF FLAN NOTE: ROOF SHEATHING AND ATTIC GABLE END WALLS SHALL BE "TECH SHIELD" RADIANT -BARRIER OR EQ. 51 NGLE PLY. ROOFING o/ #15 FELTS o/ 2x6 T$ G o/ 4x6 RAFTERS SHADED AREA TO BE UNFINISHED ATTIC, 5TORAGE REVIEWED FOR CODE COMPLIANCE AUGo 2 6 21L i ?., TRB AND ASSOCIATE'S' I/a" ;evasion: (Date: I By: N 2x4 STUDS ® 16" O.G. z tn 16d SINKER SILL ROOF IT NAILING ® 6" O.G. PLY. 100 00 M -STAGGERED I --I ++ HOUSE �cl TOP PLATE GIRDER U � TRUSS a Ubn 0 N -7- GARAGE CEILING O I RDR TRUSS DF—TA I L CUSTOM I' -O" 2x4 STRUT TO RAFTER BELOW IS 4'-0" O.G., TYP. EA. too RAFTER x6 MIN. ® 4'-0" O.G. BU I LD I NO S�=GTI ON 5-4 1/4" RIDGE 2x6 RAFTERS 2x5 FLAT W/ (2) I&d PER RAFTER BELOW CALIF. FILL DETAIL R-20 1/2" = 1'-0 C-� SECT I Oil A4 1/4" = i' -o" ROOF NOTF5: I. ROOF FRAMING SHALL BE: PRE -MFR TRUSSES ® 24" O.G. TYf'. U.O.N.. HAND FRAMING 2x6 RAFTERS ® 2'-0" O.G. w/ 2x5 HIPS, VALLEYS $ RIDGE5 WHERE INDICATED ON PLAN. 2. ROOF PITCH SHALL BE: VARIES, 5EE PLAN 5. ROOF O.H. SHALL BE: 1'-0" ® ALL G.E. 1'-O" a 6:12 PITCH I'-0" ® 10:12 PITCH 1'-0" ® 10:12 PITCH 4. ROOF COVERING SHALL BE: COMP. 5HINOLF-5 o/ 15# FELT o/ Y2" CDX OR 055. w/ Sd'5 ® (b,"12" O.G. 5. REQUIRED ATTIC VENTILATION: 4505 / 500 = 15.02 50. FT. OF NET FREE AREA VENTILATION REQUIRED. • LOW VENTING: PROVIDE (25) 5Y2"x225/a" EAVE VENTS ® .55 50. FT. EACH. TOTAL LOW VENTING PROVIDED: 7.51 50. FT. OF NET FREE AREA • HI5H VENTING: PROVIDE 61' CONT. RIDGE VENT a 0.125 50. FT. PER FT. TOTAL HIGH VENTING PROVIDED: 1.625 50. FT. OF NET FREE AREA. 6. ATTIC MOUNTED F.A.U. PROVIDE SERVICE LIGHT W 5WITGH ® AGGE55 HOLE. PROVIDE IIOV SERVICE OUTLET ® UNIT. PROVIDE 24" WIDE CATWALK FROM AGGE55 HOLE TO 50" 50. x 50" H15H CLEAR MAINTENANCE PLATFORM ® UNIT. PEnMIT 0 ES -- BUTTE COUNTY Af VEL®PMENT rt iVl� R IEINED F CODE COMPLIANCE DAT Z / BY 2x6 CALIF. FRAMING ® 24" O.G., T`(P. PER -r HAND FRAMED ROOF FLAN NOTE: ROOF SHEATHING AND ATTIC GABLE END WALLS SHALL BE "TECH SHIELD" RADIANT -BARRIER OR EQ. 51 NGLE PLY. ROOFING o/ #15 FELTS o/ 2x6 T$ G o/ 4x6 RAFTERS SHADED AREA TO BE UNFINISHED ATTIC, 5TORAGE REVIEWED FOR CODE COMPLIANCE AUGo 2 6 21L i ?., TRB AND ASSOCIATE'S' I/a" ;evasion: (Date: I By: N z tn W IT W E-� 00 M I --I ++ �cl MSI U � o U a Ubn E O F -j-, O a ' ` M W z W I --I O F -j-, O W W No. 21283 RE a 7/17, DREW5 2552 Date MARCH 2016 Scale Drawn OSTROVSKIY Job 15-2056 Sheet CJ 4 Of SEVEN Sheets NOTE: VERTICAL STEEL MAY BE OMITTED WHERE HEIGHT DOES NOT EXCEED 52" FINISH FLOOR MUST BE 1'-0" MIN. ABOVE FLOOD ELEV. #4 HORIZ: BAR 15" O.G. #4 VERT. BAR 22" O.G. E.N. FLOO ELEVATION, =LOO w/ FEMA REQS. FLOOD VENTING, VENT AREA SHALL BE EQ. TO (1) 50. IN. PER (1) • 50. FT. OF CRAWL -SPACE AREA GRADE BENEATH 1 STRUCTURE MUST BE PLAN FOR HOT. IN EQ. TO OR HIGHER RELATION TO THAN GRADE OUTSIDE d OF STRUCTURE AT ALL #4 ® 4'-0" O.G. VENT LOCATION 01" NAT. GRADE .1 i I I M I a 11=I I I=III=111 ^W H a o0 FILL -� -I � I— '*' II l2iii=��i=� j \ FOOT I NO DETA I L I F-17 6" x 6" MIN. PLYND. OU55ET5 EA. 51DE w/ (5) 8d'5 EA. TO POST 4 OIRDER—\ NAT. GRADE OEM 1" = 11_011 SEE FOUNDATION PLAN FOR FRAMING SIZES 4x4 POST TOE -NAIL TO REDND. BLOCK W (5) Sd'S MIN. PRECAST GONG. PIER 2" EMBEDMENT -' 11-1 11-1 111-II1=1II- �_� 1=1 I 1=1 I I- 11- III III -III �I' -11- I -III -II - 1-11 I I I- I I i= -"'=1 I. I I 1,,'i 11-1 I ,r- 18" Sa. FIER FOOTING F-52 III = II_011 P.T. SILL N/ Y2" DIA. x 12" A.B. ® 6' O.G. $ 12" MAX. FROM ENDS N/ 5"x5"x.221" PLATE NA5HER5, TYP. 50L I D BLKO. SILL NAIL T WAL� g�B I� NATURAL GRADE 2 2x PTDF STUDS ® I6" O.G., MATCH SIZE OF STUDS ABOVE -III III d III=III= ' —�#4 TOP _� °•=III BOTTOM 1��•�,���= 11=112„-�'I INTERIOR 100TI NO (I -STORY) F-25 1'' = 11-011 P.T. SILL W/ y2 " DIA. x 12" A.B. (9 6' O.G. AND 12" MAX. FROM ENDS N/ 5"x5"x.221" PLATE WASHERS, TYP. SLA, SEE O NDATION PLAN •LN••WIV" ...,,,���mml�lllllllllll��1111. �=�•�--_�_�•_-�•_-. • it NAT. GRADE d #4 TOP BOTTOM mi GARAGE FOOT I NO F-18 III = 1'-011 LINE OF 5TEMNALL BEYOND " FELT TYPICAL STRIP EASED EDGE DR I VENAY GONG. SLAB, SEE SLAB ---im1d � FOUNDATI ON PLAN CONT. #4 TOP $ BOTTOM z TYP. U.O.N. m O ARAO E DOOR OFEN I NO F-141 III = 1'-0 4" GONG. SLAB o/ POST, SEE FLR. PLAN BASE, SEE FLOOR PLAN FOR HOT. IN SEE FDN. PLAN FOR RELATION TO P05T BASE TYPE FIN 1 SH FLOOR. #4 ® 4'-0" O.G. 1 1/2" .Q a< a a o 0"00"0 0 o op� NAT. GRADE �� o ° 0 ° o FIN 1 SH GRADE 0 0 °�°(�Q� ° p < d ° ^W H a p°o p GRANULAR o0 FILL -"' -III-111=111=111=1I I � 6'< ° III=111=111=111=1I I -111=111=1I I z -i 11=1 11=1 I I -III � .i I I=1 I I, ; -1 11-I 11-I t I -I 11=1 11=1 11=1 11=1 11= I 14M1N° I I I=1 I I-III=1 I I=1 I I=1 I ,III 1= i i- 1-OP1 -I �.< #11410 �I1I1I� 5M - . Om FOUNDATION NOTES: FOROH FOOT I NO -57 I. PROVIDE IS"x24" MIN., SCREENED U.F. ACCESS 2. UNDER FLOOR VENTING: SEE FEMA NOTES ON 5HT. 1 5. GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL BE SLOPED AWAY FROM THE BUILDING AT A SLOPE OF NOT LE55 THAN 6” WITHIN THE FIRST 10 FT. (5% SLOPE). PER 2015 CRC SECTION R401.5 MNM Revision: I Date: I By: N V n MSI ON ^W H o0 WWF4� Cj � I� d U Q�) o w (D U O H O W � W o o W a M W 00 ' ` M W V ^W H WWF4� (2) C) (D H O W � pq o di W W No. 01283 REN. /17 Ct DREN5 2552 Date MARCH 2016 Scale Drawn OSTROVSKIY Job 15-2056 Sheet 5 Of SEVEN Sheets 11 r -I lti rl M O e� O N N N 51 ELECTRICAL 5YMBOL5 SINGLE POLE SWITCH -- GLC. MTD. FIXT. CEILING FAN w/ LIGHT �THREE WAY SWITCH FLUORESCENT 3 GLC. MTD. FIXT. KITCHEN LIGHTING DIMMER SWITCH LED GLC. MTD. FIXT. D CEILING FAN NO LIGHT D3 DIMMER/3-WAY SWITCH RECESSED GLC. FIXT. UNDER CABINET llnn W �{ FLUORESCENT LIGHTING $T TIMER SWITCH ELEG. BALLAST, LUMINAIRE TYPE: HIGH EFFICACY: WATTS: AIR -TIGHT, I G RATED FLUORESCENT FIXTURE os OCCUPANCY SENSOR YES FLUORESCENT 6 RECESSED GLC. FIXT. � SIGNAL PUSH BUTTON DUPLEX REGEPT. 32 O 0 LED 0 PUCK LIGHT RECESSED GLC. FIXT. J) 220 VOLT OUTLET 2 50 MINI RECESSED GLC. FIXT. DUPLEX SPLIT WIRED YES PANEL BOARD W - }- ALL MTD. FIXTURE E' ELEG. DISCONNECT QUAD. REGEPT. FLUORESCENT 110 V. SMOKE DETECTOR FLOOR OUTLET WALL MTD. FIXTURE COMPLIES IF A >/= B —(D— TRACK FIXTURE O EXHAUST FAN a TV OUTLET �} PENDANT LIGHT ® WHOLE HOUSE VACUUM PHONE OUTLET CONNECTION FIXTURE CM IIOv CARBON MONOXIDE eSCONCE TV/PHONE OUTLET ALARM w/ BATTERY -� MINI SCONCE FIXTURE BACKUP VP SUITABLE FOR DAMP LOCATION n MOTION -ACTIVATED SECURITY LIGHT _ AUTOMATIC GARAGE r -. DOOR OPENER L15TED IN FUEL GAS OUTLET �- — ACCORDANCE w/ UL 325, W w/ GFI OUTLET 1. ALL LIGHTING FIXTURES SHALL BE ASSUMED INCANDESCENT U.O.N. AS LED OR FLUORESCENT. 2. ALL EXTERIOR LIGHTING FIXTURES SHALL BE "SUITABLE FOR DAMP LOCATIONS" W ELECTRICAL NOTES: VENTILATION REQUIREMENTS Q I. PROVIDE AN ADDITIONAL 20 AMP BRANCH CIRCUIT FOR EACH BATHROOM AND LAUNDRY. THESE CIRCUITS SHALL I. KITCHEN VENTILATION: SERVE NO OTHER OUTLETS. A. THE KITCHEN SHALL HAVE AN EXHAUST FAN 2. ALL 15 4 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS w/ A MIN. VENTILATION RATE OF 100 CFM. INSTALLED IN BEDROOMS, FAMILY ROOMS, DINING B. THE NOISE RATING SHALL BE 3 SONE ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, MAXIMUM. 5UNROOMS, RECREATION ROOMS, HALLWAYS, CLOSETS G. THE FAN SHALL BE DUCTED TO THE OUTSIDE OR SIMILAR ROOMS, SHALL BE INSTALLED WITH A w/ A MINIMUM 5"(P SMOOTH DUCT (55' MAXIMUM COMBINATION ARG -FAULT CIRCUITS INTERRUPTERS. RUN w/ (2) ELBOWS OR FITTINGS). 3. PROVIDE (2) OR MORE 20 -AMP SMALL APPLIANCE BRANCH CIRCUITS EVENLY PROPORTIONED IN THE 2. BATHROOM �/ENTILTION: KITCHEN, PANTRY, BREAKFAST ROOM, DINING ROOM, OR SIMILAR AREA TO SERVE ALL WALL AND FLOOR A. EACH BATHROOM SHALL HAVE AN EXHAUST OUTLETS. SUCH CIRCUITS SHALL HAVE NO OTHER FAN w/ A MIN. VENTILATION RATE OF 50 CFM. OUTLETS. B. THE NOISE RATING SHALL BE 3 SONE MAXIMUM. 4. ALL 125 VOLT, 51NGLE PHASE, 15 AND 20 AMP G. THE FAN SHALL BE DUCTED TO THE OUTSIDE RECEPTACLES SHALL BE LISTED TAMPER RESISTANT W A MINIMUM 4"(P SMOOTH DUCT (75' MAXIMUM RECEPTACLES. RUN w/ (2) ELBOWS OR FITTINGS). D. BATHROOM EXHAUST FANS MUST BE 5. FIXTURES, LAMP HOLDERS AND RECEPTACLES OUTLETS CONTROLLED BY A HUMID15TAT CONTROL SHALL BE SECURELY SUPPORTED. A FIXTURE THAT CAPABLE OF ADJUSTMENT BETWEEN A WEIGHS MORE THAN blbs OR EXCEEDS I61n. IN ANY RELATIVE HUMIDITY RANGE OF 50 TO 809. DIMENSION SHALL NOT BE SUPPORTED BY THE SCREW 2013 00550 SECTION 4.506. SHELL OF A LAMP HOLDER PER 2013 CEO SECTION 410.15. (a). OUTLET BOXES SHALL NOT BE USED AS THE 5. WHOLE - BUILDING VENTILATION: SOLE SUPPORT FOR CEILING FANS PER 2013 SECTION 314.27 (a 8 d). SEE GF I R FOR WHOLE BUILDING VENTILATION REQUIRED CFM. 6. ALL HARDWIRED DETECTORS SHALL BE INTERCONNECTED. ONE BATHROOM FAN SHALL BE 70 CFM. MIN. w/ A MAXIMUM NOISE RATING OF I SONE. THE SWITCH 7. ALL GARAGE, LAUNDRY ROOM, AND UTILITY ROOM SHALL BE LABELED VENTILATION CONTROL. LIGHTING SHALL BE HIGH -EFFICACY AND CONTROLLED BY A MANUAL -ON OCCUPANCY SENSOR. VERIFY LOCATION 7A/C UNIT 220 GF I WP/ I I I DINING ROOM I I I � � \ GOVR'D PATIO � IWP/ I WP/ ------L----- GFI GFI — — — — — — — — — — — _ s GFI GFI goo 6FIG I �LFII \ 617I it FAMILY MSTR.a DOOM 6FI 2 O GFI — BATH — 9 GFI I 1 viP \ I \ \ \ 6FI \ I GFI I \ �I KITCHEN BATH 5r GFI FI GFI 6FI GF I \ / ............ — — NOTE: PROVIDE LIGHT \ $ 110 VOLT OUTLET AT \ ATTIC ACCESS $ ATTIC \ \ MTD. F.A.U. / / I OARAGE I 1 -i I\ I rI \ L -> GFI \ i \ NOTE: GARAGE RECEPTACLES TO BE +IS" MIN. A.F.F. GFI dh6FI-------- F__ 2'-0" MIN. GLR- GF I GFI a GREAT / ROOM W.I.G. MA5TER BEDROOM EXERUSE ROOM r_� GF I IFENTRY 6F I I -� 3- _ HALL w � o � � - - GF I I � / _-- JE D3 D BATH 2 � @CM 1 L DRY GFI GFI --- 6F I PORCH / BEDROOM 5 (9� BEDROOM 2 o \\ I \ I I � I I I I / WP/ 6F i PERMITk ' w BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE _ ._ �-'V �1,/ �-) L�- -_ _---BY REVIEWED FOR C;(lI• F C1IMPLIANCE AI3(i 3 a018 ` RIB AND ASSOCIATES ELECTRICAL PLAN 1/4"= 11-011 Revision: [Date: By: NaN KITCHEN LIGHTING SCHEDULE: z llnn W A B LUMINAIRE TYPE: HIGH EFFICACY: WATTS: QUANTITY: HIGH EFFICACY WATTS: OTHER WATTS: COMPACT FLUOR. YES 26 6 156 4' FLUOR. TUBE YES 32 O 0 3' FLUOR. TUBE YES 25 2 50 2' FLUOR. TUBE YES 17 1 17 A/ w u u bD TOTAL (A): 223 TOTAL (B): 0 COMPLIES IF A >/= B YES X NO o o VERIFY LOCATION 7A/C UNIT 220 GF I WP/ I I I DINING ROOM I I I � � \ GOVR'D PATIO � IWP/ I WP/ ------L----- GFI GFI — — — — — — — — — — — _ s GFI GFI goo 6FIG I �LFII \ 617I it FAMILY MSTR.a DOOM 6FI 2 O GFI — BATH — 9 GFI I 1 viP \ I \ \ \ 6FI \ I GFI I \ �I KITCHEN BATH 5r GFI FI GFI 6FI GF I \ / ............ — — NOTE: PROVIDE LIGHT \ $ 110 VOLT OUTLET AT \ ATTIC ACCESS $ ATTIC \ \ MTD. F.A.U. / / I OARAGE I 1 -i I\ I rI \ L -> GFI \ i \ NOTE: GARAGE RECEPTACLES TO BE +IS" MIN. A.F.F. GFI dh6FI-------- F__ 2'-0" MIN. GLR- GF I GFI a GREAT / ROOM W.I.G. MA5TER BEDROOM EXERUSE ROOM r_� GF I IFENTRY 6F I I -� 3- _ HALL w � o � � - - GF I I � / _-- JE D3 D BATH 2 � @CM 1 L DRY GFI GFI --- 6F I PORCH / BEDROOM 5 (9� BEDROOM 2 o \\ I \ I I � I I I I / WP/ 6F i PERMITk ' w BUTTE COUNTY DEVELOPMENT SERVICES REVIEWED FOR CODE COMPLIANCE DATE _ ._ �-'V �1,/ �-) L�- -_ _---BY REVIEWED FOR C;(lI• F C1IMPLIANCE AI3(i 3 a018 ` RIB AND ASSOCIATES ELECTRICAL PLAN 1/4"= 11-011 Revision: [Date: By: NaN z llnn W 4 00 p•l ) M ++ • � Ell*�� � Iii d U Q !y A/ w u u bD U o o � F4 C W W o ro W W M W z W H --I w H Q Q (D O O F4 ro W W No. C21183 REN. 7 -17 DREW5 2552 Date MARCH 2016 Scale Drawn 05TR0V5KIY Job 15-2056 Sheet 6 Of SEVEN Sheets m CL 10 cn qqT CD a-1 O N N N TITLE 24 MANDATORY MEASURES 6-7 BUILDING F-WELOPE MEASURES I. DOORS AND WINDOWS BETWEEN CONDITIONED AND UNCONDITIONED SPACES SHALL BE MANUFACTURED TO LIMIT AIR LEAKAGE. 2. FENESTRATION PRODUCTS (EXCEPT FIELD -FABRICATED WINDOWS) SHALL HAVE A LABEL LISTING THE CERTIFIED U -FACTOR, CERTIFIED SOLAR HEAT GAIN COEFFICIENT (SHOO), AND INFILTRATION THAT MEETS THE REQUIREMENT5 OF §I0-111(0). 3. EXTERIOR DOORS AND WINDOWS SHALL BE WEATHER-5TRIPPED; ALL JOINTS AND PENETRATIONS CAULKED AND SEALED. 4. INSULATION SPECIFIED OR INSTALLED SHALL MEET STANDARDS FOR INSULATING MATERIAL. INDICATE TYPE AND INCLUDE ON GF -61R, FORM. 5. THE THERMAL EMITTANCE AND SOLAR REFLECTANCE VALUES OF THE COOL ROOFING MATERIAL MEETS THE REQUIREMENT5 OF §110.8(l) WHEN THE INSTALLATION OF A COOL ROOF IS SPECIFIED ON THE GF -IR FORM 6. A RADIANT BARRIER SHALL HAVE AN EMITTANGE OF 0.05 OR LESS WHEN THE INSTALLATION OF A RADIANT BARRIER 15 SPECIFIED ON THE GFIR. 1. LOOSE FILL INSULATION SHALL CONFORM WITH MANUFACTURER'S INSTALLED DESIGN LABELED R -VALUE E I REPLACES DECORATIVE GAS APPLIANCES AND GAS LOC MEA51LIRE5: I. MASONRY OR FACTORY -BUILT FIREPLACES SHALL HAVE A CLOSABLE METAL OR GLAS5 DOOR COVERING THE ENTIRE OPENING OF THE FIREBOX. 2. MASONRY OR FACTORY -BUILT FIREPLACES SHALL HAVE A COMBUSTION OUTSIDE AIR INTAKE, WHICH 15 AT LEAST 51X 5QUARE INCHES IN AREA AND 15 EQUIPPED w/ A READILY ACCESSIBLE, OPERABLE, AND TIGHT -FITTING DAMPER AND OR A COMBUSTION -AIR CONTROL DEVICE. 3. MASONRY OR FACTORY -BUILT FIREPLACES HAVE A FLUE DAMPER WITH A READILY ACCESSIBLE CONTROL. 4. CONTINUOUS BURNING PILOT LIGHTS AND THE USE OF INDOOR AIR FOR COOLING A FIREBOX JACKET, WHEN THAT INDOOR AIR IS VENTED TO THE OUTSIDE OF THE BUILDING, ARE PROHIBITED. 5PACE CONDITIONING WATER HEATING AND PLUMBING SYSTEM MEA5URE5 I. HVAC EQUIPMENT, WATER HEATERS, SHOWERHEADS, FAUCETS AND ALL OTHER REGULATED APPLIANCES SHALL BE CERTIFIED BY THE ENERGY COMMISSION. 2. WATER HEATER RECIRCULATION LOOPS SERVING MULTIPLE UNITS MEET THE AIR RELEASE VALVE, BACKFLOW PREVENTION, PUMP ISOLATION VALVE, AND RECIRCULATION LOOP CONNECTION REQU I REMENT5. 3. CONTINUOUSLY BURNING PILOT LIGHTS ARE PROHIBITED FOR NATURAL OAS: FAN -TYPE CENTRAL FURNACES, HOUSEHOLD GOOKIN5 APPLIANCES (APPLIANCES w/OUT AN ELECTRICAL SUPPLY VOLTAGE CONNECTION w/ PILOT LIGHTS THAT CONSUME LESS THAN 150 Btu/hr ARE EXEMPT), AND POOL AND SPA HEATERS. 4. HEATING AND/OR OOOLINO LOADS SHALL BE CALCULATED IN ACCORDANCE w/ ASHRAE, SMIAGNA OR ACOA. 5. INSTALLED AIR CONDITIONER AND HEAT PUMP OUTDOOR CONDENSING UNITS SHALL HAVE A CLEARANCE OF AT LEAST V FROM THE OUTLET OF ANY DRYER VENT. 6. HEATING SYSTEMS SHALL BE EQUIPPED w/ THERM05TAT5 THAT MEET THE SETBACK REQUIREMENTS OF SECTION 110.2(0). 7. STORAGE GAS WATER HEATERS RATED w/ AN ENERGY FACTOR NO GREATER THAN THE FEDERAL MINIMAL STANDARD SHALL BE EXTERNALLY WRAPPED W/ INSULATION HAVING AN INSTALLED THERMAL RESISTANCE OF R-12 OR GREATER. 8. UNFIRED HOT WATER TANKS, SUCH AS STORAGE TANKS AND BACKUP STORAGE TANKS FOR 50LAR WATER -HEATING SYSTEMS, HAVE R-12 EXTERNAL INSULATION OR R -I6 INTERNAL INSULATION R -VALUE 15 INDICATED ON THE EXTERIOR OF THE TANK. a. FIRST 5 FT. OF HOT AND GOLD WATER PIPES CLOSEST TO WATER HEATER TANK, ALL PIPING WITH A NOMINAL DIAMETER OF J" OR LARGER, ALL PIPING A55001ATEED w/ A DOMESTIC HOT WATER RECIRCULATION SYSTEM REGARDLESS OF THE PIPE DIAMETER, PIPINO FROM THE HEATING SOURCE TO STORAGE TANKS, PIPING BURIED BELOW GRADE, AND ALL HOT WATER PIPES FROM, THE HEATING SOURCE TO KITCHEN FIXTURES MUST BE INSULATED ACCORDING TO THE REQUIREMENTS TABLE 120.3-A. 10. ALL DOMESTIC, HOT WATER PIPES THAT ARE BURIED BELOW GRADE MUST BE INSTALLED IN A WATER PROOF AND NON -CRUSHABLE CASING OR SLEEVE THAT ALLOWS FOR INSTALLATION, REMOVAL, AND REPLACEMENT OF THE ENCLOSED PIPE AND INSULATION. II. PIPE FOR COOLINO SYSTEM LINES SHALL BE INSULATED A5 5PEGIFIED IN §150.0(J)2A. PIPING INSULATION FOR STEAM AND HYDRONIC HEATING SYSTEMS OR HOT WATER SYSTEMS WITH PRESSURE >15 p519 SHALL MEET THE REQUIREMENTS IN TABLE 120.3-A. 12. INSULATION SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT DUE TO SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE, AND HIND. 13. INSULATION EXPOSED TO WEATHER SHALL EITHER BE RATED FOR OUTDOOR USE OR INSTALLED WITH A COVER SUITABLE FOR OUTDOOR SERVICE. 14. INSULATION FOR CHILLED WATER PIPING AND REFRIGERANT SUCTION LINES SHALL INCLUDE A VAPOR RETARDANT OR BE ENCLOSED ENTIRELY IN CONDITIONED SPACE. 15. SYSTEMS USING OA5 OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE: A 120V ELECTRICAL RECEPTACLE WITHIN 3' OF THE WATER HEATER; A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH A 5TRAIOHT PIPE BETWEEN THE OUTSIDE TERMINATION AND THE SPACE WHERE THE WATER HEATER 15 INSTALLED; A CONDENSATE DRAIN THAT IS NOT MORE THAT 2 HIGHER THAT THE BASE OF THE INSTALL, ED WATER HEATER AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE; AND A OAS SUPPLY LINE WITH A CAPACITY OF AT LEAST 200,000 BTU/HR- 16. RECIRCULATING LOOPS 5ERVING MULTIPLE DWELLING UNITS SHALL MEET THE REQUIREMENTS OF §110.3(0)5 17. SOLAR WATER -HEATING SYSTEMS AND COLLECTORS SHALL BE CERTIFIED AND RATED BY THE SOLAR RATINGS AND CERTIFICATION CORPORATION OR BY A TE5TING AGENCY APPROVED BY THE EXECUTIVE DIRECTOR. DUCTS AND FAN MEASURES: I. ALL AIR -DISTRIBUTION SYSTEM DUCTS AND PLENUMS INSTALLED, ARE SEALED AND INSULATED TO MEET THE REQUIREMENTS OF GMC, SECTIONS 601, 602, 603, 604,605 AND AN51/5MAONA-006-2006 HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE 5rd ADDITION. SUPPLY -AIR AND RETURN -AIR DUCTS AND PLENUMS ARE INSULATED TO A MINIMUM INSTALLED LEVEL OF R-6.0 OR ENCLOSED ENTIRELY IN CONDITIONED SPACE AS CONFIRMED THROUGH FIELD VERIFICATION AND DIAON05TIO TESTING. CONNECTIONS OF METALS DUCTS AND INNER GORE OF FLEXIBLE DUCTS ARE MECHANICALLY FASTENED. OPENIN55 SHALL BE SEALED w/ MASTIC, TAPE OR OTHER DUCT-01-05URE SYSTEM THAT MEETS THE APPLICABLE REQUIREMENTS OF UL -181, UL 181A, OR UL 195I5 OR AEROSOL SEALANT THAT MEETS THE REQUIREMENTS OF UL -723. IF MASTIC OR TAPE 15 USED TO SEAL OPENINGS GREATER THAN Y4 INCH, THE COMBINATION OF MASTIC AND EITHER MESH OR TAPE SHALL BE USED. 2. BUILDING GAVITIE5, SUPPORT PLATFORMS FOR AIR HANDLERS, AND PLENUMS DEFINED OR CONSTRUCTED w/ MATERIALS OTHER THAN SEALED SHEET METAL, DUCT BOARD OR FLEXIBLE DUCT SHALL NOT BE USED FOR CONVEYING CONDITIONED AIR. BUILDING CAVITIES AND SUPPORT PLATFORMS MAY CONTAIN DUCTS. DUCTS INSTALLED IN CAVITIES AND SUPPORT PLATFORMS SHALL NOT BE COMPRESSED TO CAUSE REDUCTIONS IN THE CRO55-5ECTIONAL AREA OF THE DUCTS. DUCT 5Y5TEM5 SHALL COMPLY w/ SPECIFIED FOR DUCT CONSTRUCTION, AND CLOSURES; JOINT5 AND 5EAM5 OF DUCT SYSTEMS AND THEIR COMPONENTS SHALL NOT 3. FACTOR FABRICATED BE SEALED w/ CLOTH BACK RUBBER ADHESIVE DUCT TAPES UNLE55 SUCH TAPE 15 USED IN COMBINATION w/ MASTIC AND DRAW BONDS. 4. FIELD FABRICATED DUCT SYSTEMS SHALL COMPLY w/ REQUIREMENTS FOR DUCT CONSTRUCTION, CONNECTIONS, AND CLOSURES, AND OTHER REQUIREMENTS SPECIFIED FOR DUCT CONSTRUCTION DUCT INSULATION R -VALUE RATING; DUCT INSULATION THICKNESS; AND DUCT LABELING. FAN SYSTEMS THAT EXCHANGE AIR BETWEEN ORIGINAL CONDITIONED SPACE AND THE OUTSIDE SHALL HAVE BACK DRAFT OR AUTOMATIC DAMPERS. AND 5. ALL INLET A 6. GRAVITY VENTILATING SYSTEMS 5ERVING CONDITIONED SPACE SHALL HAVE EITHER AUTOMATIC OR READILY ACCESSIBLE, MANUALLY OPERATED DAMPERS EXCEPT COMBUSTION L OUTLET AIR OPENIN05 AND ELEVATOR SHAFT VENTS. SHALL BE PROTECTED FROM DAMAGE, INCLUDING THAT DUE TO SUNLIGHT, MOISTURE, EQUIPMENT MAINTENANCE, AND WIND, BUT NOT LIMITED TO THE FOLLOWING; INSULATION 1. INSULATION F-XP05ED TO WEATHER SHALL BE SUITABLE FOR OUTDOOR SERVICE. CELLULAR FOAM INSULATION SHALL BE PROTECTED AS, ABOVE OR PAINTED WITH A COATING THAT IS WATER RETARDANT AND PROVIDES SHIELDING FROM SOLAR RADIATION THAT CAN CAUSE DEORADATION OF THE MATERIAL. 8. FLEXIBLE DUCT5 CANNOT HAVE POROUS INNER GORES. q. WHEN SPACE GONDITIONING SYSTEMS USE FORGED AIR SYSTEMS TO SUPPLY CONDITIONED AIR TO AN OCCUPIABLE SPACE, THE DUCTS SHALL BE SEALED AND DUCT LEAKAGE TESTED, AS, CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH REFERENCE RESIDENTIAL APPENDIX RA3. 10. MECHANICAL SYSTEMS THAT SUPPLY AIR TO AN OCCUPIABLE SPACE THROUGH DUCTWORK EXCEEDING 10' IN LENGTH AND THROUGH A THERMAL CONDITIONING COMPONENT, EXCEPT EVAPORATIVE COOLERS, SHALL BE PROVIDED w/ AIR FILTERS DEVICES THAT MEET THE REQUIREMENTS OF §I50.0(m)12. Il. SPACE CONDITIONING SYSTEMS THAT UTILIZE FORGED AIR DUCTS TO SUPPLY COOLING TO AN OCCUPIABLE SPACE SHALL HAVE A HOLE FOR THE PLACEMENT OF A STATIC, PRE55URE PROBE (HSPP), OR A PERMANENTLY INSTALLED STATIC PRESSURE PROBE (P5PP) IN THE SUPPLY PLENUM. THE SPACE CONDITIONING SYSTEM MUST ALSO DEMONSTRATE AIRFLOW <_ 0.58 W/CFM AS CONFIRMED BY FIELD VERIFICATION AND DIAGN05TIC TESTING, IN ACCORDANCE w/ REFERENCE RESIDENTIAL APPENDIX RA3. 12. ZONALLY CONTROLLED CENTRAL FORGED AIR COOLING SYSTEMS SHALL BE CAPABLE OF SIMULTANEOUSLY DELIVERINO, IN EVERY ZONAL CONTROL MODE, AND AIRFLOW FROM THE DWELLINO, THROUGH AIR HANDLER FAN AND DELIVERED TO THE DWELLINO, OF 5 350 GFM PER TON OF NOMINAL COOLING CAPACITY, AND OPERATING AT AN AIR -HANDLING UNIT FAN EFFICACY OF 50.58 W/CFM AS CONFIRMED BY FIELD VERIFICATION AND DIAGNOSTIC TESTING, IN ACCORDANCE WITH REFERENCE APPENDIX RA3. 13. ALL DWELLING UNITS SHALL MEET THE REQUIREMENTS OF A5HRAE STANDARD 62.2. NEITHER WINDOW OPERATION NOR CONTINUOUS OPERATION OF CENTRAL FORGED AIR 5Y5TEM AIR HANDLER5 USED IN CENTRAL FAN INTEGRATED VENTILATION SYSTEMS ARE PERM1551BLE METHOD OF PROVIDING THE WHOLE BUILDING VENTILATION. 14. WHOLE BUILDING VENTILATION AIRFLOW SHALL BE CONFIRMED THROUGH FIELD VERIFICATION AND DIAGNOSTIC, TESTING, IN ACCORDANCE w/ REFERENCE RESIDENTIAL APPENDIX RA3.YAH RESIDENTIAL LIOHTINO MEASURES: I. INSTALLED LUMINARIES SHALL BE CLA551FIEV AS, HIGH-EFFIGAGY OR LOW -EFFICACY FOR COMPLIANCE WITH §150.0(k) IN ACCORDANCE WITH TABLE 150.0-A OR TABLE 150.05, AS APPLI GABLE. 2. WHEN A HIGH EFFICACY AND LOW EFFICACY LIGHTING SYSTEM ARE COMBINED IN A 51NOLE LUMINAIRE, EACH SYSTEM SHALL SEPARATELY COMPLY WITH THE APPLICABLE PROVI510N5 OF §150.0(k). 3. THE WATTAGE AND CLASSIFICATION OF PERMANENTLY INSTALLED LUMINARIES IN RESIDENTIAL KITCHENS SHALL BE DETERMINED IN ACCORDANCE w/ §130.0(0). IN RESIDENTIAL KITCHENS, THE WATTAGE OF ELECTRICAL BOXE5 FINISHED w/ A BLANK COVER OR WHERE NO ELECTRICAL EQUIPMENT HAS BEEN INSTALLED, AND WHERE THE ELECTRICAL BOX CAN BE USED FOR A LUMINAIRE OR A SURFACE MOUNTED CEILING FAN, SHALL BE CALCULATED AS 180 WATT5 OR LOW EFFICACY 1-I51-ITIN5 PER ELECTRICAL BOX. 4. BALLASTS FOR FLUORESCENT LAMPS RATED 13 WATTS OR GREATER SHALL BE ELECTRONIC AND SHALL HAVE AN OUTPUT FREQUENCY NO LE55 THAN 20 kHz. 5. PERMANENTLY INSTALLED NIGHT LIGHTS AND NIGHT INTEGRAL TO INSTALLED LUMINAIRE OR EXHAUST FAN SHALL BE RATED TO CONSUME NO MORE THAN FIVE WATT5 OF POWER PER LUMINAIRE OR EXHAUST FAN AS DETERMINED IN ACCORDANCE w/ §130.0(0). NIGHT LIGHTS DO NOT NEED TO BE CONTROLLED BY VACANCY SENSORS. 6. LIGHTING INTEGRAL TO EXHAUST FANS, IN ROOMS OTHER THAN KITCHENS, SHALL MEET THE APPLICABLE REQUIREMENTS OF §I50.0(k) 1. HIGH EFFICACY LUMINIAIRES MUST BE SWITCHED SEPARATELY FROM LOW EFFICACY LUMINAIRES. 8. EXHAUST FANS SHALL BE 5WITGHED SEPARATELY FROM LIGHTING SYSTEMS. a. LUMINAIRES SHALL BE 5WITGHED w/ READILY ACCESSIBLE CONTROLS THAT PERMIT THE LIMINAIRES TO BE MANUALLY 5WITGHED ON AND OFF. 10. NO CONTROL SHALL BYPASS A DIMMER OR VACANCY SENSOR FUNCTION IF THE CONTROL IN INSTALLED TO COMPLY w/ §150.0(k). II. LIGHTING CONTROLS COMPLY w/ APPLICABLE REQUIREMENTS OF §IIO.cf. 12. AN ENERGY MANAGEMENT CONTROL SYSTEM (EMGs) MAY BE USED TO COMPLY w/ DIMMER REQUIREMENTS IF; IT FUNCTIONS AS A VACANCY SENSOR. 13. A MULT15CENE PROORAMMABLE CONTROLLER MAY BE USED w/ DIMMER REQUIREMENTS IF IT PROVIDES THE FUNCTIONALITY OF A DIMMER. 14. A MINIMUM OF 50 PERCENT OF THE TOTAL RATED WATTAGE OF PERMANENTLY INSTALLED LIGHTING IN KITCHENS SHALL BE HIGH EFFICACY. 15. KITCHEN LIGHTING INCLUDES ALL PERMANENTLY INSTALLED LIGHTING IN THE KITCHEN EXCEPT INTERNAL LIGHTING IN CABINETS THAT ILLUMINATE ONLY THE INSIDE OF CABINETS. LIGHTING IN AREAS ADJACENT TO THE KITCHEN, INCLUDING BUT NOT LIMITED TO DINING AND NOOK AREAS, ARE CONSIDERED KITCHEN LIGHTING IF THEY ARE NOT SEPARATELY 5WITGHED FROM THE KITCHEN LIGHTING. I6. PERMANENTLY INSTALLED LIGHTING THAT IS INTERNAL TO CABINETS SHALL USE NO MORE THAN 20 WATTS OF POWER PER LINEAR FOOT OF ILLUMINATED CABINET. 1-1. A MINIMUM OF ONE HIGH EFFICACY LUMINAIRE SHALL BE INSTALLED IN EACH BATHROOM; AND ALL OTHER LIOHTIN5 INSTALLED IN EACH BATHROOM SHALL BE HIGH EFFICACY OR CONTROLLED BY VACANCY SENSOR. ETACHED GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS SHALL BE HIGH EFFICACY, AND CONTROLLED BY VACANCY SENSORS. 18. PERMANENTLY INSTALLED LUMINAIRES IN ATTACHED AND D AN KITCHENS, BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS SHALL BE HIGH EFFICACY la. PERMANENTLY INSTALLED LUMINAIRES LOCATED IN ROOMS OR AREAS OTHER TH LUMINAIRES, OR CONTROLLED BY EITHER DIMMERS OR VACANCY SENSORS. 20.LUMINAIRE5 RECESSED INTO INSULATED CEILINGS SHALL BE LISTED FOR ZERO CLEARANCE INSULATION CONTACT (IC) BY UNDERWRITTEN LABORATORIES OR OTHER NATIONALLY RECOGNIZED TE5TING/RATING LABORATORY; AND HAVE A LABEL THAT CERTIFIES THE LUMINAIRE 15 AIRTIGHT WIT AIR LEAKAGE LE55 THEN 2.OGFM AT -15 PASCALS WHEN TESTED IN ACCORDANCE WITH A5TM E283; AND BE SEALED WITH A GASKET OR CAULK BETWEEN THE LUMINAIRE HOUSING AND CEILING. FOR RECESSED COMPACT FLUORESCENT LUMINAIRES w/ BALLASTS TO QUALIFY AS, HIGH EFFICACY. 21. LUMINAIRES PROVIDING OUTDOOR LIGHTING, INCLUDING LIGHTING FOR PRIVATE PATIOS IN LOW-RISE RESIDENTIAL BUILDINGS WITH FOUR OR MORE DWELLING UNITS, ENTRANCES, BALCONIES, AND PORCHES, WHICH ARE PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING OR TO OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY. EXCEPTION I: PERMANENTLY INSTALLED OUTDOOR LOW EFFICACY LUMINAIRES SHALL BE ALLOWED PROVIDED THAT THEY ARE CONTROLLED BY A MANUAL-ON/OFF SWITCH, A MOTION SENSOR NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES THE MOTION SENSOR, AND ONE OF THE FOLLOWINO CONTROLS: A PHOTOGONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES THE PHOTOGONTROL; OR AN ASTRONOMICAL TIME CLOCK NOT HAVING AN OVERRIDE OR BYPA55 5WITGH THAT DISABLES, THE ASTRONOMICAL TIME CLOCK; OR AN ENERGY MANAGEMENT CONTROL SYSTEM (EMOS) NOT HAVING AN OVERRIDE OR BYPASS 5WITGH THAT ALLOW5 THE LUMINAIRE TO BE ALWAYS ON. EXCEPTION 2: OUTDOOR LUMINAIRES USED TO COMPLY WITH EXCEPTIONAL MAY BE CONTROLLED BY A TEMPORARY OVERRIDE SNITCH WHICH BYPASSES THE MOTION 5EN51NG FUNCTION PROVIDED THAT THE MOTION SENSOR 15 AUTOMATICALLY REACTIVATED WITHIN 51X HOURS. 22. INTERNALLY ILLUMINATED ADDRESS SIGNS SHALL COMPLY WITH SECTION 140.&; OR SHALL CONSUME NO MORE THAN 5 WATT5 OF POWER. 23. LIGHTING FOR PARKING LOTS AND CARPORTS WITH A TOTAL OF 8 OR MORE VEHICLES PER 51TE SHALL COMPLY WITH THE APPLICABLE REQUIREMENT5 IN SECTIONS 130, 132, 134, AND 14-1. LIGHTING FOR PARKING OARAOE5 FOR 8 OR MORE VEHICLES SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF SECTIONS 130, 131, 134, AND 146. 24. PERMANENTLY INSTALLED LIGHTING IN THE ENCLOSED, NON DWELLING 51-AGE5 OF LOW-RISE RE5I1PENTIAL BUILDING WITH 4 OR MORE DWELLING UNITS SHALL BE HIGH EFFICACY LUMINAIRES. EXCEPTION: PERMANENTLY INSTALLED LOW EFFICACY LUMINAIRES SHALL BE ALLOWED PROVIDED THAT THEY ARE CONTROLLED BY AN OCCUPANT 5ENSOR(5) CERTIFIED TO COMPLY WITH THE APPLICABLE REQUIREMENTS. SOLAR READY BU I LD I NOS: I. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A MINIMUM 5U55AR RATING OF 200 AMPS. 2. THE MAIN ELECTRICAL SERVICE PANEL SHALL HAVE A RESERVED SPACE TO ALLOW FOR THE INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR ELECTRIC, INSTALLATION. THE RESERVED SPACE SHALL BE: POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION, PERMANENTLY MARKED AS "FOR FUTURE SOLAR ELECTRIC". 2013 CALGreen Residential Mandatory Measures Planning and Design 4.106.2 - Storm Water Drainage and Retention - Projects which disturb less than one acre of soil and are not part of a larger common plan of development shall manage storm water drainage during construction. 4.106.3 - Grading and Paving - Construction plans shall indicate how the site grading and drainage system will manage all surface water flows to keep water from entering building. Exception: Additions or alterations not altering the drainage path. 4.106.4.1- Electric Vehicle (EV) charging - For new constructed dwelling units, install a listed raceway to accommodate a dedicated 208/240 -volt branch circuit. The raceway shall not be less than trade size 1(nominal 1 -inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40 -ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. The service panel or subpanel circuit directory shall identify the overcurrent protective device spaces(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". Energy Efficiency 4.201.1-5.201.1- Low-rise residential (Section 4.201.1) and high-rise residential/hotel/motel (Section 5.201.1) building shall meet or exceed the minimum standards design required by the California Energy Standards. Standards for residential buildings do not require compliance with levels of minimum energy efficiency beyond those required by the 2013 California Energy Code. Water Efficiency and Conservation Indoor Use - 4.303.1- Water Conserving Plumbing Fixtures and Fittings. - Plumbing fixtures and fittings shall comply with the following: 4.303.1.1 - Water closets flush volume shall not exceed 1.28 gals per flush. 4.303.1.2 - Urinals flush volume shall not exceed 0.5 gals per flush. 4.303.1.3.1- Single showerheads shall have a maximum flow rate of not more than 2.0 gpm. 4.303.1.3.2 - Multiple showerheads shall have a combined flow rate of all showerheads and/or shower outlets controlled by a single valve shall not exceed 2.0 gpm or only one shower outlet to be in operation at a time. 4.303.1.4.1- Residential lavatory faucets maximum flow rate shall not exceed 1.5 gpm. The minimum flow rate shall not be less than 0.8 gpm. 4.303.1.4.2 - Lavatory faucets in common and public areas of residential buildings shall not exceed 0.5 gpm. r 4.303.1.4.3 -Metering faucets shall not deliver more than 0.25 gals per cycle. 4.303.1.4.4 - Kitchen faucets maximum flow rate shall not exceed 1.8 gpm. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gpm. Note: When complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.2 - Plumbing fixtures and fittings shall be installed in accordance with the Plumbing Code. Outdoor Use - 4.304.1- Irrigation Controllers - Automatic irrigation system controllers for landscaping by the builder and installed at the time of final inspection shall comply with the following: 1. Controllers shall be weather- or soil moisture -based controllers that automatically adjust irrigation in response to changes in plant watering needs as weather or soil conditions change. 2. Weather -based controllers without integral rain sensors or communication systems that account for rainfall shall have a separate wired or wireless rain sensor which connects or communicates with the controller(s). Material (Conservation and Resource Efficiency 4.406.1- Rodent Proofing - Annular spaces around pipes, electric cables, or other openings in sole/bottom plates at exterior walls shall be closed with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency to prevent passage of rodents. 4.408.1 -(Construction Waste Reduction of at least 50% - A minimum of 50% of the construction waste generated at site is diverted to recycle or salvage. 4.408.2 Construction Waste Management Plan - Submit a construction waste management plan meeting items 1-5 in Section 4.408.2. Plans shall be undated as necessary and shall be available for examination during construction. 4.408.3 - Waste Management Company - Utilize a waste management company, approved by the enforcing agency, which dan provide verifiable documentation that diverted construction and demolition waste materials meet the requirements in Section 4.408.1. 4.408.4 -Waste Stream Reduction Alternative - Generate a total combined weight of construction and demolition waste disposed in landfills that is equal to or less than 4 lbs per sq. ft. of the building area. 4.408.4.1 - Waste Stream Reduction Alternative (High -Rise Residential) - Generate a total combined weight of construction and demolition waste disposed in landfills that is equal to or less than 2 lbs per sq. ft. of the building area. 4.410.1- Operation & Maintenance Manual - An operation and maintenance manual shall be provided to the building owner or occupant. Environmental Quality 4.503.1 General - Any installed gas fireplace shall be a direct -vent sealed -combustion type. Any installed woodstove or pellet stove shall comply with US EPA Phase II emission limits where applicable. Woodstoves, pellet stoves, and fireplaces shall also comply with applicable local ordinances. 4.504.1 Coverings of Duct Openings and Protection of Mechanical Equipment during Construction - Duct openings and other related air distribution component openings shall be covered during construction. 4.504.2.1. - Adhesives, Sealants and Caulks - Shall be compliant with VOC and other toxic compounds limits. 4.504.2.2 - Paints and Coatings - Shall be compliant with VOC limits. 4.504.2.3 - Aerosol Paints and Coatings - Shall be compliant with product weighted MIR limits for ROC and other toxic compounds. 4.504.3 - Carpet Systems - Shall be compliant with VOC limits. 4.504.4 -• Resilient Flooring Systems - 80% of floor areas receiving resilient flooring shall comply with the VOC - emission limits defined in the Collaborative for High Performance Schools (CHPS) Low -emitting Materials List or to be certified under the Resilient Floor Covering Institute (RFCI) FloorScore Program. 4.504.5 - Composite Wood Products - Particleboard, medium density fiberboard (MDF) and hardwood plywood used in interior finish systems shall comply with low formaldehyde emission standards. 4.505.2 - Concrete Slab Foundations - A vapor retarder and capillary break is installed at slab on grade foundations. 4.505.3 - Moisture Content of Building Materials - Wall and floor framing materials shall be checked before enclosure. 4.506.1- Bathroom Exhaust Fans - Exhaust fans which terminate outside the building are provided in every bathroom. 4.507.2 - Heating and Air Conditioning System Design - Duct systems are sized , designed, and equipment selected using the following methods: 1. Establish heat loss and heat gain values according to ACCA Manual J or equivalent. 2. Size duct systems according to ACCA 29-D (Manual D) or equivalent. 3. Select heating and cooling equipment according to ACCA 36-S (Manual S) or equivalent. Installed & Special Inspection Qualifications 702.1- HVAC system installers are trained and certified in the proper installation of HVAC systems and equipment. 702.2 Special inspectors must be qualified and able to demonstrate competence to the enforcing agency in the discipline in which they are inspecting. 703.1- Documentation - Verification of compliance with the code may include construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods of acceptable to the enforcing agency which show substantial conformance. TABLE 4.504.1 ADHES3I E VOC LIMfT1,2 d i E,An%mt I-'n>r�arl�atnrf in irvn *e mr l 4;r APCHITE+CTUAALAPPUCATICINS 1. CUPPENTV0r LIMIT 10`c� r car wt adItc5i•ie `y Ca rlyt ro J a d h i 5t Outdoor c< wt tiiht sick I�171 Wc,od 110 -•-Tin ntih t 1+° I?uha flmr adicsi,'O I uhflnor xllt _-i vc- ' Cerarnie tilew adhk.-_Nh!t�. 65 VCT and as h 11t the adhekKv:. (°f Dtvv,, all ark pa 1 adhc 5two �Il 14wti ndh 6, iVeK 3 f�, i _ nstruetnn n��hew~ia 7' rtl 211i74np adh -shvs 1(' 0 ysi-lic-,A P r�API m�mhrnixil)'"iE 25U()thCr ttt � i'$� not eilj� 11 °lita`_ PENALTY APPLICATIONS - PVC weldirw :510 Its ATS S vvlid ino -' PI as:tic Cc Merit V v Ptp comi e i ;Ar. llw-,zi v irrr°r ror t ki c 1350 Nux lin shine c pins F �: it tl ,t�.� �� c��ttltasl a�:tllc• �i���� ,�O Strun_tur:ll aa•i c%J tnrotheraidh,o;ive l-.0 76 in and Lrini ak1he 'r,)� 250 ,9UE3 TRATE SPECIFIC APPLICATIONS F_xln-mis7.r ,cpn lands Nle tsl tri -rn: ta.l t Pl a-tii: f,: a,- ' pon-Iuf;matorial(exce:t% c ;i ' 'tiVn rid taiN� n1lmS If an adh4 sive is u s d to h -rid di ssi milar- suhstra zs the adliwsi .t %vith the highest N'fOCcontent shrallNz allso-v &- Torudditi -mcA inf-armutic-n rrcardiin g rnithod to nwa-iti the "y`fi.�' content rpt iho-1 in 1ldr table, sty: South Coast Ar Quality Nlana,gernenr. Bi,ctrict Rille 1166. TABLE 4504.2 SEALANT VOC LIIA(T, I ,a -_-a t Atarr;:ind ILo,.q Evorn t Cilrnr ounds lit Grams r Litor SEALANTS 01111P ENT WO L%1 IT �, rx:li it�d : tiir�al `y N1a ri iy.� dedz 7t++ Nm 14) nodwav 2501 Single- l y rr i merghraln I oth"r 4�yi SEALANT liPRAEIRS ,Al nminn m ►�+t f cc?aUra �+.rr_h I ct tlt�il Nrin p-wous 2-0) res modillo,d Ntur in:nus �Il N1 n bac del 3 f�, Other 7 J, cA-hm�- Of4C��er and i.rcludin-,, , e mpt ��� con"_ inds- - 'The Te ifie-dlimiisr{niainineffeNtunle-srvv s dlimiLhr•'li"i dinssjb-,e= qiicntac:lairrins. in tlr lila*: . N511u,--z in this table -H- d2dVW Irt-fru Vit �{+ :ii d t7 tt,:c alifi-nua fir. Res-,-urccs Boarct. Achii ,-lural Coatings Sup esttA Control Meaisur . Fehruaiy, 1 2t108. Mire int-rmation is-ailahle fronai the Air te�lurte..:% Foan-1 T&RLE 4,504.5 170FIlt1AL.Dr"YDE LIMIT I Irt Vnr-fa niur I.Till'ion PA L)VCT t. r iaai: EFFECTIVE EFFE TI';<E nat c%,I it iilus 5 1 0,05 Ti41�nard 1".1�xiiarm +3eriLv i its Cl-+f"ti"ii"K1 t4lrinMt-lyl b Thin me llum den sit1\T fi E2 rttiXinf- I SPECIALTY COATINGS ,Al nminn m ►�+t f cc?aUra > IM �it'filerlt'� _i�nit� +C�11'ai��a �Il i lirtninous w:tf coaliitrxs' Bi bnninolis mo riinwi Bond ha �r� M a -n - fWD f nficro'? sutra " wvi potm't - C, enc tt*3mn urs al i- Its C±ri� r a1rs V v Ptp comi e i l Nux lin shine c pins ncx,r cowiri", l F_xln-mis7.r ,cpn lands ch -whip- aft!r-, i n"s ri i n ii°rtsl M h tem a ca ti l fe coMin 's Indastrial Imirtt Low SII d titin$i'ry Ma uc i to cement C itta,L -f 142 41c, teTn-Ire' caaatln S 1f1. I oolliz I�MLIT)16, ,attifi5170 1411ltiCIat#x nein s' Pfetfe:it m'" t u ash rif ner Prifrk2fX. mentees. Rat ufl d "-rcolife l 4 pv. 3'rri- q5t F,-CV0 i ati_n ,g :290 P.af c+-salifi Rim ,fovatcai'ma Cf0 ifi-A 250 Sb el l-1: Cjearr Opaque T 3r+ S +fix iiit. rimrtr . woler n9 nt rr ?a► r lien ir�il� z 'tti�* Ci!+itifj�lfil 450 Ss�-irncnirta 1 e�atin�rR �.9 Troflic marl.inp CoatiflEs 1ts0 Tub and filer -finish cnadfr s 'Cl tiler ronfrnf tneinl+ranes 251' idj atitlrn•'gyy Y-� �iyt'r g Ii w bib -.6:h prim ers J, cA-hm�- Of4C��er and i.rcludin-,, , e mpt ��� con"_ inds- - 'The Te ifie-dlimiisr{niainineffeNtunle-srvv s dlimiLhr•'li"i dinssjb-,e= qiicntac:lairrins. in tlr lila*: . N511u,--z in this table -H- d2dVW Irt-fru Vit �{+ :ii d t7 tt,:c alifi-nua fir. Res-,-urccs Boarct. Achii ,-lural Coatings Sup esttA Control Meaisur . Fehruaiy, 1 2t108. Mire int-rmation is-ailahle fronai the Air te�lurte..:% Foan-1 T&RLE 4,504.5 170FIlt1AL.Dr"YDE LIMIT I Irt Vnr-fa niur I.Till'ion PA L)VCT t. r iaai: X11 RRVIT WAIT T-- ardwood .Iyvvo,-.A- n,crc:orc, k05 1tsrd d1y%,Ao;A% nip. 'siv,Q*rsw 0,05 Ti41�nard 1".1�xiiarm +3eriLv i its Cl-+f"ti"ii"K1 1?.l.l Thin me llum den sit1\T fi E2 rttiXinf- I in 1hi. obi d ciycal frnui ftro,vspcd i -d trj the r'ali:fnnni Air Rep:?urce% 13,oaf-d, Air Toxics C"Arml Ntc3 S"'M for CnM170"ite NVOO'i LIS t.-sLe�d i -n acrenrdance w'it`h ASTh•1 E. 13, ' 3-1. For add itionA, irlPm ati-on;, 2 r'th i��xG• � ttf�t r+P' +> .Titt�17, ?cLions4 I20thi„ai h931120-12. 2. Titin 2dium demily 1IN ri- VRI IxLsa rn:i-ximUrn tl itl ii srwf a�aa> 1i i8rnmr, n PERMIT q6�0 BUTTE COUNTY DEVFLOPMENT SERVICES REVIEWED FOR �CODE COMPLIANCE DATE Z/ ' go' I (_0 BY_� REVIEWED FOR CODE COMPLIANCE e TRB AND ASSOCIATE NOTE: THE PROJEGT MANA6ER OR GENERAL GONTRAGTOR WILL 5E THE RESPONSIBLE PERSON TO GOLLEGT AND PRO�/IDE VERIFICATION OF GALCREEN GOMPLIANGE TO THE BUILDING INSPEGTOR PRIOR TO BUILDING SINAL. wision: • By: C1 'n V / 00 Cl Q� O dP �' U ami U tA e� O "C W C r•a 0 M 00 rn a A 0 A. * No. C ►�_ REN 7/17 VSIDENTIAL CALCREEN MANDATORY MEA5URE5 Date 2016 Scale Drawn Job Sheet Of CG w