HomeMy WebLinkAboutB16-0591 039-520-009Periods only used on one word abbreviations, if the abbreviationABBREVIATIONS a different word by itself; e.g. ARCH., BIT., and I
Periods are usually used when abbreviating multiple words, unless they
are very common without periods; e.g. AFF, HVAC:, R/A, and WWM.
THE PROJECT SHALL COMPLY WITH THE FOLLOWING BUILDING CODES:
CALIFORNIA BUILDING CODE (BASED ON 2009 IBC)
CALIFORNIA RESIDENTIAL (BASED ON 2009 IBC)
CALIFORNIA GREEN BUILDING STANDARDS CODE
CALIFORNIA PLUMBING CODE (BASED ON 2009 UPC)
CALIFORNIA MECHANICAL CODE (BASED ON 2009 UMC)
CALIFORNIA ELECTRICAL CODE (BASED ON 2008 NEC)
CALIFORNIA ENERGY STANDARDS, TITLE 24 (AS OF OCTOBER 1, 2005)
CALIFORNIA FIRE CODE (BASED ON 2009 IFC)
CALIFORNIA ENERGY STANDARDS (BASED ON 2005 ECS)
ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL CODES
AND
S UAH FOOTAGES
FA FIRE ALARM
PAR PARALLEL
SQ. FT.
@
F
FAS FASTEN(ER)
P.BD. PARTICLE BOARD
Z
a
C CENTERLINE
FAU FORCED AIR UNIT
P.B. PUSH BUTTON
CS COVER SHEET
d PENNY
oo N
F.B. FACE BRICK
PC. CONC. PRECAST CONCRETE
a� o %,
NUS
# POUND / NUMBER
F.B.O. FURNISHED BY OTHERS
PDR POWDER
P PROPERTY LINE
F.D. FLOOR DRAIN
P.E. PORCELAIN ENAMEL
�
0 ROUND / DIAMETER
�
F.E. FIRE EXTINGUISHER
PED PEDESTAL (SINK)
O
�
F.F. FINISH FLOOR (LINE)
PERI PERIMETER
ANCHOR BOLT
F.G. FINISHED GRADE
PKG PARKING
AA.B.
ABV ABOVE
FGL FIBERGLASS
PL PLATE (HEIGHT)
A/C AIR CONDITIONING
FIN FINISH
P.LAM. PLASTIC LAMINATE
ACC ACCESS
FLG FLASHING
PLAS PLASTER
AC.T. ACOUSTICAL TILE (CLG)
FLR FLOOR(ING)
PNL PANEL
AFF ABOVE FINISH FLOOR
FL FLORESCENT (LIGHT)
PNT PAINT(ED)
A.D. AREA DRAINP.O.C.
FN FENCE
POINT OF CONNECTION
ADD ADDENDUM
FND FOUNDATION
PR PAIR (OF)
ADH ADHESIVE
F.O. FACE OF
PREFAB PREFABRICATED
ADJ ADJUSTABLE
F.O.S. FACE OF STUD
PSF POUNDS PER SQUARE FOOT
AGG AGGREGATE
FP FIRE PROOF
PSI POUNDS PER SQUARE INCH
A.H.U. AIR HANDLING UNIT
FPL FIREPLACE
PIN PARTITION
ALT ALTERNATE
FR FRAME(D)(ING)
P.T. PRESSURE TREATED (WOOD)
ALUM ALUMINUM
FS FULL SIZE
PV PAVE(D) OR PAVING
A.P. ACCESS PANEL
FT FOOT / FEET
PVC POLYVINYL CHLORIDE (PIPE)
APX APPROXIMATE
FTG FOOTING
PVMT PAVEMENT
ARCH. ARCHITECT(URAL)
FUR FURRED(ING)
PWD PLYWOOD
ASPH ASPHALT
FX FIXED GLASS
A.T. ASPHALT TILE
Q.T. QUARRY TILE
AUTO. AUTOMATIC
GA GAUGE
AVE AVERAGE
GALV GALVANIZEDD
R RISER (ON STAIRS)
AWNG AWNING
GAR GARAGE R
RAG RETURN AIR GRILL
G.B. GYPSUM (WALL) BOARD
R.B. RUBBER BASE
B
B36 36" WIDE BASE CAB.
3
G.C. GENERAL CONTRACTOR
RAD RADIUS
B BATHROOM
GD GRADE OR GRADING
RBL RUBBLE
BD BOARD
G.D.O. GARAGE DOOR OPENER
RROO RENRAIN
BF B[ -FOLD (DOOR)
GFI GROUND FAULT INTERRUPTER
REF.
BIT. BITUMINOUS
GL GLASS OR GLAZING
REFR REFRIGERATOR
BLKG BLOCKING
GL.BK. GLASS BLOCK
REG REGULAR
BLDG BUILDING
G.I. GALVANIZED IRON
REQ REQUIRED
BLK BLOCK (CMUs)
GSM GALVANIZED SHEET METAL
RES RESILIENT
BLKG BLOCKING
GT GROUT
REV REVISION(S), REVISED
BM BEAM
GYP GYPSUM
REINF REINFORCED(ING)
B.M. BENCH MARK
GYP BD GYPSUM BOARD
RFG ROOFING
BP BI -PASS (DOOR)
R.J.B. REINFORCED JUNCTION BOX
BRG BEARING
42"H 42" HIGH (WALL)
RLG RAILING
BRK BRICK
H
HB HOSE BBB
R&M RANGE W/ MICROWAVE
B.S. BOTH SIDES
H.C. HOLLOW CORE
BSMT BASEMENT
HD HEAD OR HARD
R.O. ROUGH OPENING
BTM OR BOT BOTTOM
H.D. HEAT DETECTOR OR HEAVY DUTY
R.O.W. RIGHT OF WAY
BTWN BETWEEN
HDR HEADER
B.U.R. BUILT UP ROOF
HDW HARDWARE
S SOUTH
BVL BEVELED
HGT HEIGHT S
SC SOLID CORE (DOOR)
B.W. BOTH WAYS
H.M. HOLLOW METAL
SCH SCHEDULE
CAB CABINET
HORZ HORIZONTAL
SD SMOKE DETECTOR
C
C.B. CATCH BASIN
HR HOUR
H.R. HALF ROUND (WINDOW)
SEC SECTION
SERV SERVICE
CEM CEMENT
CER CERAMIC
HS HORIZONTAL SLIDER
S.F. SQUARE FEET
CF CUBIC FOOT
HTG HEATING
HVAC HEATING/VENTILATING/AIR COND.
SF.GL. SAFETY GLASS
CHAM CHAMFER
HWD HARDWOOD (FLOORS)
S.G.D. SLIDING GLASS DOOR
SH SINGLE HUNG OR SHELF(VING)
C.I. CAST IRON
C.I.P. CONC. CAST -IN-PLACE CONC.
j
I.B. IRONING BOARD
SHT (DRAWING) SHEET
CBR CIRCLE
I
I.D. INSIDE DIAMETER
SHTHG SHEATHING
CIRC CIRCUMFERENCE
I.L.O. IN LIEU OF
SIM SIMILAR
C.J. CONTROL JOINT OR CONSTRUCTION JOINT
I.M. INSULATED METAL
SKI, SKYLIGHT
CK CALK(ING) CAULK(ING)
INS OR INSUL INSULATED(TION)
SL SLOPE / SLIDING
CL CLOSET OR CENTER LINEINT
INTERIOR
SNT SEALANT
S&P SHELF AND POLE
CLG CEILING
CLR CLEARANCE)
T
JAN JANITOR
JAN
SPC SPACER
CLOSURE CLOSER (DOOR)
JST JOIST (FLOOR OR ROOF)
SPEC SPECIFICATIONS
R S)
CM CENTIMETER(S)
JT JOINT
SPK (AUDIO) SPEAKER(S)
CMU CONCRETE MASONRY UNIT
S.ST. STAINLESS STEEL
C.O. CASED OPENING
(CEILING)
KD KNOCKDOWN CE ( )
STSTANDARD
COL COLUMN
KIT KITCHEN
STG OR STO STORAGE
COMB COMBINATION
KO KNOCKOUT
SIT, STEEL
CONC CONCRETE
KPL KICKPLATE(ON DOOR)
SIR STRUCTURAL
COND (AC)CONDENSER
K/S KNEE SPACE
SQ SQUARE
CONST CONSTRUCTION
T
L LENGTH
SUS SUSPENDED
S.W. SHEAR WALL
CONT CONTINUOUS
SS SYMBOL
CONTR CONTRACTOR
L
LA LAUNDRY
S4S SMOOTH FOUR SIDES
CORR CORRUGATED
LAM. LAMINATE(D)
S&P SINGLE SHELF / SINGLE POLE
CPR COPPER
LAV LAVATORY (SINK)
2S&2P DOUBLE SHELF/DOUBLE POLE
C OR CPT CARPET
L.B.O. LOCATION BY OTHERS
2S&IP DOUBLE SHELF/ SINGLE POLE
CRS COURSE(S)
LIV LIVING
CR CORROSION RESISTANT
L.L..L. LIVE LOAD
T TREAD (AT STAIRS) OR TILE
CSMT CASEMENT
L.P. LAMINATED PLASTIC 1
T.B. TOWER BAR
C.ST. CAST STONE
LT LIGHT
T.B.D. TO BE DETERMINED
C.T. CERAMIC TILE
L.T. LAUNDRY TUB
TC TERRA COTTA
CTR CENTER OR COUNTER
LTL LINTEL
T.C.J. TROWELED CONTROL JOINT
CX CONNECTION
LUM LUMINOUS
TEMP. TEMPERED (GLASS)
CY CUBIC YARD
LVL LAM VENEER LUMBER (BEAMS)
T&G TONGUE & GROOVE
LVR LOUVER
TEL TELEPHONE
D
12"D 12" DEEP
THK THICK(NESS)
D DRYER, OR DRAIN
/�
M METERS)
THR THRESHOLD
DBL DOUBLE
M
MAX MAXIMUM
T.O.C. TOP OF CURB
DECO DECORATIVE
MAS MASONRY
T.O.F. TOP OF FOUNDATION
DEM DEMOLISH, DEMOLITION
MAIL MATERIAL
DEP DEPRESSED
MBA MASTER BATH
T.O.W. TOP OF WINDOW
DET DETAIL
MBD MASTER BEDROOM
TR OR TRN TRANSOM (WINDOW)
IW )
D.F. DRINKING FOUNTAIN
MC MEDICINE CABINET
TP TOILET PAPER HOLDER
DH DOUBLE HUNG
MECH MECHANICAL
TV TELEVISION OUTLET OR LOCATION
DIAM DIAMETER
MED MEDIUM
TYP TYPICAL
DIAL DIAGONAL
DIM DIMENSION
MET METAL
T T
MFR MANUFACTURER
UC UNDERCUT(DOOR)
DISP DISPOSAL
MI MANHOLE LJ
UNF UNFINISHED
DIV DIVERTER
MIN MINIMUM
U.N.O. UNLESS NOTED OTHERWISE
D.L. DEAD LOAD
MISC PMISOR
J
VB VANITY BASE
DN DOWN (STAIRS)
ELLANEOUS �/
V.B. VAPOR BARRIER
D.P. DAMP -PROOFING
MLD MOLDING
VB36 36" WIDE VANITY BASE
DR DOOR
MM MILLIMETER
VERT VERTICAL
DRY DRYER MACHINE
MMEMBRANE
ME
VEST VESTIBULE
DS DOWNSPOUT
M.O. MASONRY OPENING
VIN (SHEET) VINYL
D/S DRAWER STACK (CABINET)
MOD MODULAR
V.S. VEGETABLE SINK
D.T. DRAIN TILE
MRB MARBLE
VT. VINYL TILE
DTL DETAIL
MIT, METAL
V.T.R. VENT THRU ROOF
DW DISHWASHER
MT MOUNTED(ING)
DWG DRAWING
MULL MULLION OR MULLED `� ]
W3630 36"W X 30"H WALL CAB
DWG DRAWER
�/�/
W WIDE / WASHING MACHINE / WEST
E
E EAST�T
EA EACH
1 �
N NORTH
N.I.C. NOT IN CONTRACT
WC WATER CLOSET
WD WOOD
EB EYEBROW (FLAT ARCH)
NL NAILABLE
WDW WINDOW
E.F. EACH FACE
NG NATURAL GRADE
WF WIDE FLANGE (STEEL BEAM)
E.J. EXPANSION JOINT
NO NUMBER
WH WATER HEATER
ELEV ELEVATION
NOM NOMINAL
W.H. WALL HUNG
ELEC ELECTRIC(AL)
N.T.S. NOT TO SCALE
WI WROUGHT IRON
ENCL ENCLOSURE
N.G.V.D. NAT. GEODETIC VERTICAL DATUM
WIC WALK-IN CLOSET
E.P. ELECTRICAL PANEL
W/ W/O WITH OR WITHOUT
EQ EQUAL
0
OA OVERALL
WP WATERPROOF(ING)
EST ESTIMATE
OBS OBSCURE (GLASS)
W.R. WATER RESISTANT
E.W.C. ELECTRIC WATER COOLER
O.C. ON CENTER
D.C. OVERT -BAD CABINET
W.S. WATER SOFTENER
EXG EXISTING
O.D. OUTSIDE DIAMETER
WSCT WAINSCOT
W.T.W. WALL TO WALL
EXH EXHAUST
EXT EXTERIOR
O.G.D. OVERHEAD GARAGE DOOR
WWF WELDED WIRE FABRIC
OH OVERHEAD
WWM WELDED WIRE MESH
OPNG OPENING
On OPTIONAL
OSA OUTSIDE AIR
OSB ORIENTED STRAND BOARD
COVERED
9602 McANARLIN AVE.
NOTES
I . THE GENERAL CON"TRAC"TOR AND ALL SUB -CONTRACTORS SHALL CAREFULLY AND
THOROUGHLY EXAMINE THE PROJECT SITE, FIELD VERIFY ALL CONDITIONS,
GRADES, ELEVATIONS AND DIMENSIONS OF THE VARIOUS FEATURES OF THE
PROJECT SITE AND SHALL COMPARE THE DRAWINGS WITH THE EXISTING SITE
CONDITIONS. DISCREPANCIES SHALL BE REPORTED IMMEDIATELY TO THE
ARCHITECT OR ENGINEER, IN WRITING, BEFORE BEGINNING WORK.
2. THE GENERAL CONTRACTOR, AND ALL SUB -CONTRACTORS, SHALL REVIEW AND
THOROUGHLY EXAMINE AND FAMILIARIZE THEMSELVES WITH ALL ELEMENTS AND
CONDITIONS IN THE CONTRACT DRAWINGS AND SPECIFICATIONS. THE GENERAL
CONTRACTOR, AND ALL SUB -CONTRACTORS, SHALL VERIFY ALL DIMENSIONS ON
THE DRAWINGS. ANY DISCREPANCIES AND / OR CONDITIONS NEEDING
CLARIFICATION SHALL BE REPORTED IMMEDIATELY TO THE ARCHITECT OR
ENGINEER, IN WRITING, BEFORE BEGINNING WORK.
3. ALL CONSTRUCTION, FABRICATION AND INSTALLATIONS SHALL CONFORM TO THE
LATEST FEDERAL, STATE AND LOCAL CODES, REGULATIONS AND ORDINANCES OF
THE GOVERNING AGENCY HAVING JURISDICTION OVER THE PROJECT. SUCH
APPLICABLE CODES, ETC., ARE THOSE WHICH ARE IN EFFECT AT THE TIME THE
PERMIT APPLICATION FOR THE PROJECT IS RECORDED.
4. EACH TRADE SHALL BE RESPONSIBLE FOR KNOWLEDGE OF RELATIVE
INFORMATION CONTAINED IN THESE DOCUMENTS AND THE CONDITIONS UNDER
WHICH HE WILL BE EXPECTED TO PERFORM.
5. DUE TO REPROGRAPHIC PROCESSES, THESE PLANS MAY NOT BE ACCURATE AND TO
SCALE. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE SHOWN AND, IN
NO CASE, SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, SECTIONS,
ELEVATIONS OR DETAILS.
6. THE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS ARE
SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. SHOULD THERE BE ANY
DISCREPANCY BETWEEN THE VARIOUS DRAWINGS, IT SHALL BE BROUGHT TO THE
ARCHITECT'S / ENGINEER'S ATTENTION FOR CLARIFICATION.
7. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER'S REPRESENTATIVE FOR
INSTALLATION OF SPECIAL MANUFACTURING EQUIPMENT NOT SHOWN IN THESE
DRAWINGS.
8. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF
THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR FIRST CLASS
WORK; FOR THE TRADE INVOLVED, THE DEVELOPER SHALL BE NOTIFIED
IMMEDIATELY, IN WRITING, OF ANY ALTERNATE NON-STANDARD OR UNTESTED
METHOD(S) PROPOSED.
9. ALL EXISTING UTILITIES OR STRUCTURES ARE INDICATED ON THESE PLANS BASED
ON INFORMATION OF RECORD. THE CONTRACTOR SHALL TAKE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES NOT OF RECORD OR NOT SHOWN ON
THESE PLANS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY AND ALL
DAMAGES WHICH OCCUR DUE TO HIS FAILURE TO LOCATE AND PROTECT ANY AND
ALL UNDERGROUND UTILITIES.
10. THE GENERAL CONTRACTOR, AND ALL SUB -CONTRACTORS, SHALL BE
RESPONSIBLE FOR THE ENFORCEMENT OF ALL REQUIREMENTS AND REGULATIONS
AND SHALL PERFORM ALL WORK ON THIS PROJECT IN COMPLIANCE WITH THE
STATE OF CALIFORNIA OCCUPATIONAL SAFETY AND HEALTH ACT.
11. AS REQUIRED, THE GENERAL CONTRACTOR, AND SUB -CONTRACTORS, SHALL
CLEAN, PATCH AND / OR REPAIR ALL SURFACES DAMAGED BY DEMOLITION OR
ALTERATION OF WORK, AS ASSOCIATED WITH EACH TRADE.
12. THE GENERAL CONTRACTOR, AND SUB -CONTRACTORS, SHALL BE RESPONSIBLE
FOR THE REMOVAL OF ALL DEBRIS FROM THE BUILDING PREMISES, AS ASSOCIATED
WITH EACH TRADE. BUILDING TRASH RECEPTACLES ARE NOT TO BE USED FOR
CONSTRUCTION DEBRIS.
13. FURNITURE & FIXTURES TO BE FURNISHED BY OWNER, INSTALLED BY
CON TRACTOR.
LEGEND
ELEVATION KEY OR SECTION KEY
SHEET NUMBER
DETAIL NUMBER OR SECTION KEY
SHEET NUMBER
ANGLE
F1 NOTE NUMBER
REVISION NUMBER (DELTA)
A
SHEET NUMBER
D <I-1 B
C ELEVATION LETTER
® EARTH
SAND OR GRAVEL FILL
2X4 WOOD STUD WALLS, U.N.O
EXISTING WALLS, U.N.O.
2X6 WOOD STUD WALLS, U.N.O.
® BRICK, U.N.O.
o . v..: CONCRETE
® DIMENSIONAL LUMBER
BLOCKING
® INSULATION
SEE WALL SCHEDULE ON CONSTRUCTION
DOCUMENTS FOR WALLS NOT LISTED ON
THIS SCHEDULE.
PATIO
DURHAM, CA 95938
PROJECT INFORMATION
THE PROJECT SHALL COMPLY WITH THE FOLLOWING BUILDING CODES:
CALIFORNIA BUILDING CODE (BASED ON 2009 IBC)
CALIFORNIA RESIDENTIAL (BASED ON 2009 IBC)
CALIFORNIA GREEN BUILDING STANDARDS CODE
CALIFORNIA PLUMBING CODE (BASED ON 2009 UPC)
CALIFORNIA MECHANICAL CODE (BASED ON 2009 UMC)
CALIFORNIA ELECTRICAL CODE (BASED ON 2008 NEC)
CALIFORNIA ENERGY STANDARDS, TITLE 24 (AS OF OCTOBER 1, 2005)
CALIFORNIA FIRE CODE (BASED ON 2009 IFC)
CALIFORNIA ENERGY STANDARDS (BASED ON 2005 ECS)
ALL OTHER APPLICABLE STATE, COUNTY AND LOCAL CODES
2013 EDITION
2013 EDITION
2013 EDITION
2013 EDITION
2013 EDITION
2013 EDITION
2010 EDITION
2013 EDITION
2010 EDITION
S UAH FOOTAGES
V -B
LAND USE
SQ. FT.
NON - CONDITIONED AREAS:
1.0 ACRES
NEW COVERED PATIO
614
Z
a
M
CS COVER SHEET
�
oo N
C0.0 SITE PLAN
Q�
a� o %,
NUS
E�-�� a�
r
Z
�
CC3
�
O
�
COUNTY ASSESSOR INFORMATION
OCCUPANCY GROUP
R-3
CONSTRUCTION
V -B
LAND USE
RESIDENTIAL
LOT AREA
1.0 ACRES
Z
a
M
CS COVER SHEET
�
oo N
A1.0 FLOOR PLAN & ELEVATIONS
A2.0 FOUNDATION PLAN, ROOF PLAN & DETAILS
SN STRUCTURAL NOTES
SDI STRUCTURAL DETAILS
VICINITY MAP
x
PROJECT 4vti
LOCATION
lr x ilk
�e�•c a. r +�a x. �,. �, � ms's �.-x.sn-. - ^' . '�. �"w" &"', . �
Complete construction Post Debris Recovery
final report and V.O.C. documentation and
submit to Building Division prior to final
huildino insnPntinn
�y s
DAYTON D1, tai iit1NI i i W I
�.f v
t
SOL0
__ = �_w - 7
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED FOR
CODE CO PLIA E
DATE y
l")J C&4 �#T7 0
a
NOT TO SCALE
BUTTE
COUNTY
MAR 2 5 2016
k
D
DEVELOPMENT
SERVICES
R16- Osql
W
0
SHEET INDEX
O
N0,20
a
A
p
O
N
I
O
Z
a
M
CS COVER SHEET
�
oo N
C0.0 SITE PLAN
Q�
a� o %,
NUS
E�-�� a�
A1.0 FLOOR PLAN & ELEVATIONS
A2.0 FOUNDATION PLAN, ROOF PLAN & DETAILS
SN STRUCTURAL NOTES
SDI STRUCTURAL DETAILS
VICINITY MAP
x
PROJECT 4vti
LOCATION
lr x ilk
�e�•c a. r +�a x. �,. �, � ms's �.-x.sn-. - ^' . '�. �"w" &"', . �
Complete construction Post Debris Recovery
final report and V.O.C. documentation and
submit to Building Division prior to final
huildino insnPntinn
�y s
DAYTON D1, tai iit1NI i i W I
�.f v
t
SOL0
__ = �_w - 7
BUTTE COUNTY DEVELOPMENT SERVICES
REVIEWED FOR
CODE CO PLIA E
DATE y
l")J C&4 �#T7 0
a
NOT TO SCALE
BUTTE
COUNTY
MAR 2 5 2016
k
D
DEVELOPMENT
SERVICES
R16- Osql
W
CHECKED BY
DATE
03-24-16
SCALE
AS SHOWN
JOB NO.
016-015
sfwxr
C S
SIGNATURE
0
�
O
H
U
O
a
a
A
p
O
N
I
O
Z
a
CHECKED BY
DATE
03-24-16
SCALE
AS SHOWN
JOB NO.
016-015
sfwxr
C S
SIGNATURE
0
O
�
�
C�
Q�
r
Z
�
CC3
�
O
�
CHECKED BY
DATE
03-24-16
SCALE
AS SHOWN
JOB NO.
016-015
sfwxr
C S
SIGNATURE
—_—_---_—____—_—_------_—__—___--___--__—�—
~~~----_ ----�_-_—~—�
.`�.
.~~.
00,
40
I
*
�
�
�
=
—
=
ch
w
CD
d Telephone:
PROJECT - IV,
TONY FLORES 1-0-11 (530) 321-7242
NEW COVEUD PATIO -Iv��
Golden Sun e-mail:
SITE PLAN gsd@cadmama.com
Designs 22189 Samson Ave.
9602 McAnarlin Ave Corning, California
Durham, CA 95938 APN: 039-520-009 96021
03k
tz
ch
w
CD
d Telephone:
PROJECT - IV,
TONY FLORES 1-0-11 (530) 321-7242
NEW COVEUD PATIO -Iv��
Golden Sun e-mail:
SITE PLAN gsd@cadmama.com
Designs 22189 Samson Ave.
9602 McAnarlin Ave Corning, California
Durham, CA 95938 APN: 039-520-009 96021
03k
Ll
WEST ELEVATION
1/411
/4" = 1'-0"
SOUTH ELEVATION
1/411
/4" = 1'-0"
CONNECT TO POSTS, TYP.
NORTH ELEVATION
1 /4" =I '-0"
16-9"
SECTIONA
1/4 = 1-0
FLOOR PLAN
1/411
/4" = 1'-0"
ROOF ABOVE, TYP.
EDGE OF SLAB, TYP.
PER,jlT '"" c)'3-k�/
Ry
Fo
DATE BY
MMR
CHECKED BY
DATE
03-24-16
SCALE
AS SHOWN
JOB NO.
016-015
SHEET
A1,00
2E 41
SIGNATURE
#4 VERT. BAR, THRU SLAB
W/ EPDXY @ 16" O.C., TYP.
I I
8x8x16 CMU, 48" MAX. ; I
HSS 6x6x1/4", TYP.
WALL HEIGHT.
#4 BAR, EMBEDDED INTO SLAB TYP'
4" W/ EPDXY @ 16" O.C., it -Off
I 3/4" DIA. x 18" A.B., TYP.
BETWEEN VERT. BARS,TYP.
I I NON -SHRINK GROUT
SLAB PER PLAN I (5,000 PSI)
I 2' 3/16 I SLAB PER PLAN
1
A +
< v .. ® / a. e '
- v d a4..
a
" v d 4"� e4 a a v
3/16�-
_I I I d d I--- I- I I
_ � a .: �=III 111.-1 I I-
4 a. —III— - HSS 6x6x1/4 ,TYP. a• e
t o —Iii d �--
a 8" UNDER -POUR, TYP. _ - _v NATIVE SOIL TYP.
d
4 _
1/2"x12x 12 BASE PLATE, TYP. d d a 4 11
4 d
a
° v I (5) #4 BAR STIRRUPS
v d [1z a 94 a a EQ. SPACED W/#4 BAR
gl� U p ° VERT. @ EA. CORNER, TYP.
a 4 �� ! 16" M
a Typ v d
d v.
#4 BAR @ 16" O.C., TYP. I
3" CLR., TYP. I 3" CLR., TYP.
2'-6"
FTG. AT CMU WALL 3 BASE PLATE AT CORNER POSTS 2 FOOTING AT CORNER POSTS
Not to Scale Not to Scale Not to Scale
7 TYP. 5
GABLE SD 1 TYP'
SDl
EDGE NAIL ROOF PLY. I I i�11
AT GABLE TRUSS ------ ------ - - - - (ate 1
O� 5 1/2"x13 1/2" GLB
(24 V4)CC
tiQ�� •� °�F °T
0
II II
II II
II II
II II
II II
II II
II II
II II
II II
II It
- II II
II II
II II
II 11
II II 3
TYP.
SD1
II II
O
O�pC CO
9
II II
TYP. 6 I I I I
II
EAVE SD1 I I I I
II II
II II
II II
II II
II II
II II
it II
II II
II II
II II
II II
I I HSS5x5x1/4 KNEE I
I I BRACE BELOW, I
I I PER 4/SDI, I
TYP. (8) PLACES
i 5 1/2"x13 1/2" GLB
- - (24F -V4) - -
EDGE NAIL ROOF PLY.-
_ ----------------. _
AT GABLE TRUSS i I I I
it
7�T
4<{, 16'-0 2" PG9
O �
ROOF PLAN
1/411 = 1'-0"
_ - --� -
I HSS COLUMNS, TYP.
FOUNDATION PLAN
1/411 = 1'-0"
FOUNDATION PLAN STRUCTURAL NOTES
FOUNDATION PLAN STRUCTURAL NOTES:
l.) SEE TYPICAL NOTE SHEET SN AND TYPICAL DETAIL
SHEETS SDI FOR ADDITIONAL INFORMATION.
2.) PROVIDE ANCHOR BOLT SIZE AND SPACING PER
SHEAR WALL SCHEDULE AND TYPICAL DETAILS.
3.) MINIMUM SLAB SECTION:
A- 4" CONCRETE SLAB WITH #4 AT 20" O.C. E.W.
SECURELY LOCATED AT MID -DEPTH OF SLAB.
B- 2" SAND (DELETE AT EXTERIOR SLABS) -SEE
SOILS REPORT IF APPLICABLE.
C- WATERPROOF MEMBRANE (DELETE AT EXTERIOR
SLABS) -SEE SOILS REPORT IF APPLICABLE.
D- 4" FREE DRAINING MATERIAL -SEE SOILS REPORT
IF APPLICABLE.
E- PROPERLY PREPARED SUBGRADE-SEE SOILS
REPORT IF APPLICABLE.
F- CONTRACTOR TO PROVIDE CONTROL JOINTS AT
10'-0" O.C. EA. WAY MAX.
4.) DO NOT REMOVE OR MODIFY EXISTING SUPPORT
MEMBERS, EXISTING FOUNDATIONS, OR EXISTING
HARDWARE WITHOUT THE EXPRESS WRITTEN CONSENT
OF THE ENGINEER OF RECORD.
5.) PRIOR TO CONTINUING PROJECT, CONTRACTOR SHALL
FIELD VERIFY THAT ALL EXISTING FOUNDATIONS,
MEMBERS, CONNECTIONS, ETCETERA MATCH THE
INFORMATION SHOWN ON PLAN. ANY DISCREPANCIES
BETWEEN CONDITIONS SHOWN ON PLAN AND FIELD
CONDITIONS SHALL BE IMMEDIATELY BROUGHT
TO THE ENGINEER OF RECORD.
6.) BRACE EXISTING FOUNDATIONS AND STRUCTURAL
ELEMENTS AS REQUIRED DURING CONSTRUCTION.
7.) CORROSION PROTECTION BY OTHERS.
ROOF PLAN STRUCTURAL NOTES
ROOF PLAN STRUCTURAL NOTES:
1.) SEE TYPICAL NOTE SHEET SN AND TYPICAL DETAIL
SHEET SDI FOR ADDITIONAL INFORMATION.
2.) TYPICAL ROOF SHEATHING (UNO): 1/2" THICK, APA,
TECO, OR PITTSBURGH RATED SHEATHING, SPAN
RATING 32/16, EXPOSURE 1 STRUCTURAL PANELS,
APPLIED WITH LONG DIMENSION ACROSS SUPPORTS
AND ADJACENT PANELS STAGGERED WITH 4' ENDS
OFFSET 4'. EDGE NAIL WITH 8d COMMON OR
EQUIVALENT (0.131" DIA X 2 1/2") AT 6" O.C. AT
ALL PANEL EDGES, BOUNDARIES, GABLE ENDS,
BLOCKING AND WHERE INDICATED ON PLAN. FIELD
NAIL AT 12" O.C. PROVIDE 1/8" GAP AT ALL PANEL
EDGES U.N.O. BY PANEL MANUFACTURER. AT ALL LOW
SLOPE ROOFS PROVIDE (1) PANEL CLIP MIN. BETWEEN
SUPPORTS AT ABUTTING PANEL EDGES.
3.) SEE NOTE SECTION 8 -SN FOR ROOF TRUSSES BY
OTHERS.
4.) DO NOT REMOVE OR MODIFY EXISTING SUPPORT
MEMBERS, EXISTING FOUNDATIONS, OR EXISTING
HARDWARE WITHOUT THE EXPRESS WRITTEN CONSENT
OF THE ENGINEER OF RECORD.
5.) PRIOR TO CONTINUING PROJECT, CONTRACTOR SHALL
FIELD VERIFY THAT ALL EXISTING FOUNDATIONS,
MEMBERS, CONNECTIONS, ETCETERA MATCH THE
INFORMATION SHOWN ON PLAN. ANY DISCREPANCIES
BETWEEN CONDITIONS SHOWN ON PLAN AND FIELD
CONDITIONS SHALL BE IMMEDIATELY BROUGHT
TO THE ENGINEER OF RECORD.
6.) BRACE EXISTING FOUNDATIONS AND STRUCTURAL
ELEMENTS AS REQUIRED DURING CONSTRUCTION.
7.) CORROSION PROTECTION BY OTHERS.
8.) ALL EXPOSED FRAMING SHALL BE PRESSURE
TREATED WITH TREATMENT PROCESS AND APPLICATION
APPROPRIATE FOR EXPOSURE ACCORDING TO MFR'S
WRITTEN GUIDELINES.
9.) ROOF TRUSS LAYOUT SHALL BE REVIEWED BY ENGINEER
AS TRUSS DESIGNS BECOME AVAILABLE FROM TRUSS
MANUFACTURER. CONTRACTOR SHALL OBTAIN SIGNED
TRUSS REVIEW LETTER FROM THE ENGINEER OF RECORD
AND BUILDING DEPARTMENT APPROVAL PRIOR TO
CONSTRUCTION.
10.) ALL STRUCTURAL MEMBERS SHALL.BE FASTENED IN
COMPLIANCE WITH 2013 CBC FASTENING SCHEDULE,
TABLE 2304.9.1, UNLESS NOTED OTHERWISE.
�OFESSIp
�- o��1NEDYgG� F
0 C 7AS18 m
EXP. g13n.�flb
o�0.
cAUFa�31ts f I%
THESE PLANS HAVE BEEN
REVIEWED FOR COMPLIANCE
/ ONLY WITH THE ATTACHED
PP?MTF �- A/ . STRUCTURAL CALCULATIONS
/T\
REV. DATE BY
No.
dN c� 0.
N CI On M
E Ev
uo z@9 � N
�O
Hkn a� on NUC\
ooQ o Q
DO4
v
0 0
� O
a �
N
U Q
O
a � O
Z
N
00
�U
Z' ct
O ;z
�'p Q
Z t/1
w �
� Q
w
DRAWN BY
MMR
CHECKED BY
DATE
03-24-16
SCALE
AS SHOWN
JOB NO.
016-015
SHEET
SIGNATUREA2,00
GENERAL STRUCTURAL NOTES
1. GENERAL
3. CONCRETE / REINFORCING CONTINUED
6. FRAMING / LUMBER CONTINUED 9.
DESIGN LOADS
A)
ALL WORK SHALL CONFORM TO THE 2013 CBC AND ALL APPLICABLE LOCAL CODES.
1)
REINFORCEMENT COVER SHALL BE AS FOLLOWS:
6-4 POSTS/TRIMMERS:
A)
THE STRUCTURE HAS BEEN DESIGNED FOR THE FOLLOWING CRITERIA PER CBC CHAPTER 16,
DIVISIONS I, II, III, AND IV U.N.O.:
B)
THE ENGINEER (SUMMIT STRUCTURAL DESIGN) HAS PROVIDED AND IS RESPONSIBLE FOR
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO SOIL: 3"
A.)
SUPPORT: SUPPORT ALL UPPER LEVEL POSTS AND TRIMMERS IN LOWER LEVELS WITH
SPECIFIC STRUCTURAL ITEMS ONLY. ALL OTHER REQUIREMENTS OF THE BUILDING CODE
CONCRETE WITH SOIL OR WEATHER EXPOSURE:
EQUIVALENT FRAMING AND BLOCK OR OTHERWISE FRAME POSTS THROUGH FLOOR SYSTEMS.
B)
SEISMIC:
INCLUDING WATERPROOFING, FIREPROOFING, DRAINAGE, HANDICAP ACCESSIBILITY, EGRESS
#5 BARS AND SMALLER 1 %"
SEISMIC IMPORTANCE FACTOR: 1
REQUIREMENTS, PARKING, AND ALL OTHER DESIGN REQUIREMENTS NOT SPECIFICALLY SHOWN
#6 BARS AND LARGER 2"
B.)
WHERE POSTS WITH COLUMN CAPS OR BEARING PLATES ARE SPECIFIED, THE LOAD IS TO BE
MAPPED SPECTAL RESPONSE ACCELERATIONS: Ss = 0.613, S1=
0.272
IN THE STRUCTURAL DESIGN CALCULATIONS, ARE THE RESPONSIBILITY OF THE CONTRACTOR OR
CONCRETE WITHOUT SOIL OR WEATHER EXPOSURE: 3/4"
TRANSFERRED TO THE FOUNDATION BY VERTICAL GRAIN ONLY, U.N.O.
SEISMIC SITE CLASS: D
OWNER. SHOULD ANY CHANGES BE MADE FROM THE DESIGN AS SPECIFIED IN THESE
SPECTRAL RESPONSE COEFFICIENTS: SDS = 0.535, SD1= 0.337, Cs = 0.36
DOCUMENTS WITHOUT THE WRITTEN APPROVAL FROM THE ENGINEER, THEN THE ENGINEER
J)
REINFORCEMENT SHALL BE GRADE 60 PER ASTM A615 U.N.O. LAP BOTTOM REINFORCING (60)
6-5 WALL FRAMING:
SEISMIC DESIGN CATEGORY: D
WILL ASSUME NO RESPONSIBILITY FOR ANY ELEMENT OR SYSTEM OF THE STRUCTURE.
BAR DIAMETERS U.N.O. AND LAP TOP REINFORCING, PLACED ABOVE 12" OF CONCRETE OR
BASIC SEISMIC -FORCE -RESISTING SYSTEM: TIMBER FRAMES
MORE, (80) BAR DIAMETERS U.N.O.
A.)
DOUBLE TOP PLATE SPLICES: SPLICES AND JOINTS IN DOUBLE TOP PLATE OF STUD BEARING
SEISMIC BASE SHEAR: 3.1 KIPS
C)
THE DRAWINGS AND CALCULATIONS REPRESENT THE FINISHED STRUCTURE, AND, UNLESS
WALL SHALL OCCUR AT THE CENTER LINE OF SUPPORTING STUD. TOP PLATE SPLICES OF STUD
RESPONSE MODIFICATION FACTOR: R = 1.5
SPECIFICALLY NOTED OTHERWISE, DO NOT SHOW THE METHOD OF CONSTRUCTION. THE
K)
#5 AND LARGER REBAR SHALL NOT BE RE-BENT.
WALLS SHALL BE 48" LONG WITH (12) 16d SINKERS EACH SIDE OF EACH SPLICE U.N.O. WHERE
ANALYSIS PROCEDURE USED: EQUIVALENT STATIC FORCE PROCEDURE
CONTRACTOR IS RESPONSIBLE FOR THE METHOD OF CONSTRUCTION, AND SHALL PROVIDE ALL
SPLICE IS INTERRUPTED, USE ST6224 STRAP U.N.O.
MEASURES NECESSARY TO PROTECT THE PUBLIC, CONSTRUCTION WORKERS, AND THE
L)
ALL REINFORCING STEEL AND ANCHOR BOLTS SHALL BE ACCURATELY LOCATED AND
C)
WIND:
STRUCTURE DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE FORMING, SHORING,
ADEQUATELY SECURED IN POSITION BEFORE AND DURING CONCRETE PLACEMENT.
B.)
FIRE BLOCKS: FIRE BLOCK STUD WALLS AT MID -HEIGHT WHERE STUD LENGTH EXCEEDS 10'-0".
WIND SPEED: 110 MPH
BRACING, SCAFFOLDING, ETCETERA.
WIND EXPOSURE: C
C.)
MIS -PLACED ANCHOR BOLTS: WHERE ANCHOR BOLTS HAVE BEEN INCORRECTLY PLACED,
D)
IF A PARTICULAR FEATURE OF CONSTRUCTION IS NOT FULLY SHOWN ON THE DRAWINGS OR IN
5. MASONRY
USE SIMPSON SET EPDXY WITH ANCHOR OF SAME DIAMETER WITH 7" EMBEDMENT IN
D)
LIVE LOADS:
THE CALCULATIONS, THEN IT SHALL BE CONSTRUCTED IN THE SAME CHARACTER AS SIMILAR
CONCRETE AND INSTALLATION PER MANUFACTURERS RECOMMENDATIONS AND CURRENT
ROOF 20 PSF
CONDITIONS THAT ARE SHOWN ON THE DESIGN DOCUMENTS.
A)
CEMENT MASONRY UNITS SHALL CONFORM TO CBC STANDARD 21-4, GRADE N, TYPE I, AND
ICC REPORT.
SHALL BE SINGLE OR DOUBLE OPEN END BOND BEAM UNITS.
E)
ANY CONDITIONS NOTED AS EXISTING MUST BE FIELD VERIFIED BY THE CONTRACTOR, AND
D.)
CRIPPLE WALLS: CRIPPLE WALLS SHALL BE A MINIMUM OF 14" IN HEIGHT. FOR LESSER
ANY DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER WITHOUT
B)
F'm MIN SHALL BE 1,500 PSI WITH COMPLIANCE VERIFIED AS REQUIRED PER CBC SECTION
HEIGHTS, STACK 2X PLATES (AND SHIM AS REQUIRED).
PROCEEDING WITH CONSTRUCTION PRIOR TO THE REVIEW OF THE ENGINEER.
2105.3.
ABBREVIATIONS
E.)
NOTCHED OR CUT STUDS: NOTCHED AND/OR CUT STUDS TO CLEAR ANCHOR BOLTS ARE
F)
ALL WATERPROOFING AND FLASHING (ROOFS, FOUNDATIONS, GARAGE FLOORS, ETC...) IS THE
C)
EACH CELL SHALL BE COMPLETELY FILLED WITH GROUT CONFORMING TO ASTM C279 TYPE S
NOT ALLOWED. STUDS SHALL HAVE FULL BEARING TO THE FOUNDATION PLATE.
RESPONSIBILITY OF THE CONTRACTOR OR OWNER.
WITH A MINIMUM STRENGTH OF 2,000 PSI.
AB
ANCHOR BOLT
K
KIPS
F.)
LET -IN BRACES: LET IN BRACES SHALL NOT BE USED FOR TEMPORARY BRACING ON ANY
ADD'L
ADDITIONAL
L
ANGLE
G)
SHOP DRAWINGS: SHOP DRAWINGS ARE SUPERCEDED BY THE STRUCTURAL DRAWINGS UNDER
D)
LAP REINFORCING THE GREATER OF 80 BAR DIAMETERS OR 3'-0".
WALL FRAME. STEEL STRAPS WHICH DO NOT REQUIRE THE CUTTING OF STUDS ARE AN
ADJ
ADJACENT
LLH
LONG LEG HORIZ.
ALL CIRCUMSTANCES. THE GENERAL CONTRACTOR SHALL VERIFY THAT ALL CONSTRUCTION IS INACCEPTABLE
ALTERNATIVE.
ALT
ALTERNATE
L
LONG LEG VERT.
FULL AGREEMENT WITH THE LATEST STRUCTURAL DRAWINGS. REVIEW OF SHOP DRAWINGS BY
E)
LOCATE ANCHOR BOLTS WITHIN 2�� OF THE CENTER OF A CELL.
ARCH
ARCHITECTURAL
LONG
LONGITUDINAL
THE ENGINEER OF RECORD DOES NOT GUARANTEE IN ANY WAY THE THE SHOP DRAWINGS ARE
G.)
SEE NOTE 6-1 D FOR SILL AND ANCHOR BOLT SPECIFICATIONS.
BLDG
BUILDING
LVL
LONG SLOTTED HOLE
CORRECT, NOR DOES IT INFER THAT THEY SUPERCEDE THE STRUCTURAL DRAWINGS.
BLKG
BLOCKING
LVL
LAMINATED VENEER LUMBER
6. FRAMING/LUMBER
H.)
WALL FRAMING RECEIVING NAILING AT 3" ON CENTER OR LESS SHALL BE 3X NOMINAL U.N.O.
BM
BEAM
MAX
MAXIMUM
H)
WALL FINISH SYSTEMS SUCH AS STUCCO SHALL BE APPLIED OVER FOAM BASE OR OTHER
PER PLANS AND DETAILS.
BO,TT (B)
BOTTOM
MB
MACHINE BOLTS
METHOD OF ADEQUATELY ALLOWING THE FINISH TO EXPAND AND CONTRACT WITHOUT
6-1 MATERIALS:
BTF
BEAT TO FIT
MECH
MECHANICAL
CRACKING. THE OWNER OR CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DEFECTS IN THE
6-6 CONNECTIONS:
BTWN
BETWEEN
MFR
MANUFACTURER
FINISHES.
A.)
SHEATHING:
CB
CARRIAGE BOLTS
MIN
MINIMUM
1. ROOF SHEATHING: SEE PLANS
A.)
HOLES FOR THROUGH BOLTS SHALL BE DRILLED 1/16" OVERSIZE.
CCJ
CONTROL JOINT
MISC.
MISCELLANEOUS
1)
SPECIAL INSPECTION: SPECIAL INSPECTION PER SECTION 1701 OF THE CBC SHALL BE PROVIDED
2. FLOOR SHEATHING: SEE PLANS
CIP
CAST PLACE CONCRETE
MNL
METAL
FOR THE FOLLOWING TYPES OF CONSTRUCTION:
3. WALL SHEATHING: SEE PLANS
B. )
ALL BOLTS, NUTS, AND LAG SCREWS SHALL BE PROVIDED WITH FLAT OR MALLEABLE
CJ
TR
CONSTRUCTION JOINT
(N)
NEW
WELDING OF STRUCTURAL OR REINFORCING STEEL
WASHERS WHERE BEARING AGAINST WOOD.
CLR
CLEAR
NS
NEAR SIDE
EPDXY/MECHANICAL CONCRETE ANCHORS
B.)
GLUE -LAMS: GLUE -LAMS SHALL BE 24F -V4 U.N.O. WITH A CAMBER OF R=1600' U.N.O.
CMU
CONCRETE MASONRY UNITS
NSA
NELSON STUD ANCHOR
THE SPECIAL INSPECTOR SHALL BE ACCEPTABLE TO THE STRUCTURAL ENGINEER AND BUILDING
GLUE -LAMS EXPOSED TO WEATHER MUST BE RATED FOR EXTERIOR USE BY THE MANUFACTURER.
C.)
ALL BOLTS AND LAG SCREWS SHALL BE TIGHTENED UPON INSTALLATION AND RE -TIGHTENED
COL
COLUMN
NTS
NOT TO SCALE
DEPARTMENT, SHALL BE ICBO QUALIFIED, AND THEIR EXPERIENCE SHALL BE COMMENSURATE
GLUED LAMINATED FABRICATON SHALL BE PERFORMED IN AN APPROVED FABRICATORS SHOP
BEFORE CLOSING IN OR AT COMPLETION OF JOB.
CONC
CONCRETE
OC
ON CENTER
WITH THIS TYPE OF PROJECT.
IN ACCORDANCE WITH CBC 2303.1.3, AITC A190.1, AND ASTM D 3737. BEAM INSPECTION
CONN
CONNECTION
OD
OUTSIDE DIAMETER
CERTIFICATES SHALL BE SUBMITTED TO THE FIELD INSPECTOR PRIOR TO COMPLETION OF FRAME
D.)
LAG SCREWS SHALL BE SCREWED, NOT DRIVEN, INTO PLACE.
CONSTR
CONSTRUCTION
OH
OPPOSITE HAND
INSPECTION IN ACCORDANCE WITH CBC 1704.2.
CONT
CONTINUOUS
OPNG
OPENING
2. SITE WORK /FOUNDATIONS
CONTR
CONTRACTOR
OVS
OVERSIZE ROUND HOLE
C.)
MICRO -LAMS: MICRO -LAMS (LAMINATED VENEER LUMBER) SHALL HAVE FB = 3100 PSI AND
8. ROOF
FRAMING
CP
COMPLETE PENETRATION
PDF
POWDER DRIVEN FASTENER
A)
ASSUMED MAXIMUM SOIL BEARING = 1500 PSF PER CBC TABLE 1806.2 (NO SOILS REPORT
FV = 285 PSI MIN., AND SHALL BE MANUFACTURED, APPROVED AND IDENTIFIED AS PER NER-481.
CTR
CENTER
PERP
PERPENDICULAR
PROVIDED).
8-1 PREFABRICATED ROOF TRUSSES:
CTSK
COUNTERSINK
PL
PLATE
D.)
SILL PLATES: SILL PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR WITH 1/2" DIAMETER
DBL
DOUBLE
PLWD
PLYWOOD
B)
BUILDING SITE IS ASSUMED TO BE DRAINED AND FREE OF CLAY OR EXPANSIVE SOIL. ENGINEER
ANCHOR BOLTS AND 3" X 3" X.229" PLATE WASHERS LOCATED AT 6'-0" O.C. MAX. WITH
A)
PREFABRICATED ROOF TRUSSES: PREFABRICATED ROOF TRUSSES SHALL BE DESIGNED BY THE
DF
DOUGLAS FIR
PLCS
PLACES
HAS NOT MADE A GEOTECHNICAL REVIEW OF SITE, ANY OTHER CONDITIONS ENCOUNTERED
ONE BOLT LOCATED 1'-0" MAXIMUM FROM EACH END OF EACH PIECE. RE -TREAT CUT ENDS
TRUSS FABRICATOR PER THE REQUIREMENTS OF THE ARCHITECTURAL AND STRUCTURAL
DF -L
DOUGLAS FIR - LARCH
PP
PARTIAL PENETRATION
MUST BE BROUGHT TO THE ATTENTION OF THE ENGINEER.
WHERE REQUIRED.
DRAWINGS AND CBC 2303.4.
DIA
DIAMETER
PT
PRESSURE TREATED
DJ
DOUBLE JOIST
P/C
PRECAST CONCRETE
C)
THESE CALCULATIONS ASSUME STABLE, UNDISTURBED SOILS AND LEVEL OR STEPPED FOOTINGS.
E.)
FRAMING LUMBER: ALL FRAMING LUMBER SHALL BE DOUGLAS FIR LARCH AS GRADED BY THE
B)
COMPLETE CALCULATIONS AND SHOP DRAWINGS INCLUDING LAYOUT, SIZE OF MEMBERS, AND
EA
EACH
P/T
POST -TENSIONED
ANY OTHER CONDITIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO
W.W.P.A. OR W.C.L.I.B. AND SHALL HAVE A MOISTURE CONTENT LESS THAN 19%, U.N.O.
CONNECTION DETAILS, STAMPED AND SIGNED BY AN ENGINEER LICENSED IN THE STATE OF
EF
EACH FACE
REINF
REINFORCEMENT
THE CONSTRUCTION OF THE FOUNDATIONS.
CALIFORNIA, SHALL BE REVIEWED BY THE ENGINEER OF RECORD PRIOR TO TRUSS FABRICATION.
EL
ELEVATION (DATUM)
REQ'D
REQUIRED
1. STUDS SHALL BE STUD GRADE OR BETTER.
ELEV
ELEVATION (VIEW) OR ELEVATOR
SC
SLIP CRITICAL
D)
ALL FOOTINGS INCLUDING RETAINING WALL FOOTINGS, SPREAD FOOTINGS, WALL FOOTINGS,
2. ALL POSTS SHALL BE DF -L #1 U.N.O.
C)
TRUSS DESIGN LOADS:
EN
EDGE NAILING
SEOR
STRUCTURAL ENGINEER OF
AND GRADE BEAMS SHALL BEAR ON UNDISTURBED SOIL WITH A FOOTING DEPTH BELOW
3. 2X AND 3X RAFTERS SHALL BE DF -L #2 U.N.O.
TOP CHORD LIVE LOAD: 20 PSF REDUCIBLE
EQ
EQUAL
RECORD
FROSTLINE (12" TO 24" AS PER LOCAL REQUIREMENTS).
4. 2X JOISTS SHALL BE DF -L #2 U.N.O.
TOP CHORD DEAD LOAD: 8 PSF
ES
EACH SIDE
SHTG
SHEATHING
5. CONCEALED BEAMS SHALL BE DF -L #2.
BOTTOM CHORD DEAD LOAD 5 PSF
(E)
EXISTING
SIM
SIMILAR
E)
BOTTOM OF ALL FOUNDATION TRENCHES SHALL BE CLEAN AND LEVEL.
6. EXPOSED BEAMS SHALL BE DF -L #1 APPEARANCE GRADE FOHC (4X6 AND LARGER).
TOTAL LOAD 33 PSF
EXP
EXPANSION
SOG
SLAB -ON -GRADE
7. ALL BEAMS 6X AND LARGER SHALL BE FREE OF HEART CENTER.
UPLIFT LOAD AS REQUIRED BY THE 2013 CBC
EXT
EXTERIOR
STD
STANDARD
F)
ALL FINISHED GRADE SHALL SLOPE AT A MINIMUM SLOPE OF 5% AWAY FROM ALL
EW
EACH WAY
STIFF
STIFFENER
FOUNDATIONS A MINIMUM OF 10 FEET HORIZONTAL.
F.)
NAILS: ALL NAILS SHALL BE COMMON U.N.O. WHERE EXPOSED TO WEATHER OR WITHIN 18"
D)
TRUSS BRIDGING SHALL BE AS REQUIRED AND SPECIFIED BY THE TRUSS FABRICATOR.
FF
FINISH FLOOR
STL
STEEL
OF FOUNDATION, NAILS SHALL BE GALVANIZED.
FIN
FINISH
SQ
SQUARE
G)
FOUNDATIONS SHALL NOT BE SCALED FROM PLAN OR DETAIL DRAWINGS.
E)
TRUSS MANUFACTURER SHALL OBTAIN ALL NECESSARY APPROVALS FROM THE PUBLIC AGENCIES
FJ
FLOOR JOIST
SS
STAINLESS STEEL
G.)
BOLTS AND LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O. AND
INVOLVED IN GOVERNING CONSTRUCTION.
FLR
FLOOR
SWS
SHEAR WALL SCHEDULE
H)
FILL MATERIAL SHALL BE FREE FROM DEBRIS, VEGETATION, AND OTHER FOREIGN SUBSTANCES.
PROVIDED NEW AND WITHOUT EXCESSIVE RUST.
FNDN
FOUNDATION
SYM
SYMMETRICAL
F)
TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING MAXIMUM DEFLECTIONS UNDER DESIGN
FOHC
FREE OF HEART CENTER
T&B
TOP & BOTTOM
1)
USE 4" DIAMETER PERFORATED PIPE SUB -DRAIN BEHIND ALL RETAINING WALLS. SLOPE PIPE
H.)
ALL HARDWARE CALLED SHALL BE SIMPSON STRONG -TIE CO., OR ENGINEER APPROVED
LOADS: LIVE LOAD DEFLECTION = L/360, TOTAL LOAD DEFLECTION = L/240
FOS
FACE OF STUD
TO(P)
TOP OF (PLYWOOD)
TO DRAIN TO DAYLIGHT.
EQUIVALENT, INSTALLED PER MANUFACTURER'S RECOMMENDATIONS WITH ALL HOLES FILLED
FS
FAR SIDE
TOC
TOP -OF -CONCRETE
WITH RECOMMENDED FASTENERS. USP HARDWARE MAY BE USED IN LIEU OF SIMPSON
FTG
FOOTING
TOF
TOP -OF -FOOTING
J.)
FOR FOOTINGS PLACED ON OR ADJACENT TO SLOPES, A GEOTECHNICAL ENGINEER MUST
HARDWARE WITH WRITTEN APPROVAL FROM STRUCTURAL ENGINEER OF RECORD. ALL METAL
GA
GAUGE
TOS
TOP -OF -STEEL
APPROVE FOOTING PLACEMENTS IN VIOLATION OF FIGURE 1808.7.1 OF 2013 CBC. THIS
HANGERS, CONNECTORS, AND FASTENERS IN CONTACT WITH PRESSURE TREATED WOOD SHALL
GALV
GALVANIZED
TOW
TOP -OF -WALL
ENGINEER SHALL NOT BE LIABLE FOR ANY FOUNDATION NOT IN STRICT CONFORMANCE TO
BE STAINLESS STEEL OR OTHERWISE CERTIFIED BY THE MANUFACTURER TO RESIST CORROSION
GLB
GLUE -LAM BEAM
TN
TOE NAIL
SECTION 1808 OF THE 2013 CBC.
CAUSED BY THE SPECIFIC TREATMENT APPLIED TO THE WOOD AND/OR METALS.
HDG
HOT DIPPED GALVANIZED
TYP
TYPICAL
HDR
HEADER
LINO
UNLESS NOTED OTHERWISE
K.)
WHERE LOADING TO EXISTING FOUNDATIONS IS NOT SUBSTANTIALLY INCREASED OR MODIFIED,
6-2 GENERAL
FRAMING:
HGR
HANGER (SIMPSON)
VERT
VERTICAL
NO DESIGN RECOMMENDATIONS HAVE BEEN MADE FOR THE SUITABILITY OF THE EXISTING
HORIZ
HORIZONTAL
WP
WORKPOINT
FOUNDATIONS. ONLY THOSE FOUNDATIONS WHERE LOADS HAVE BEEN ADDED BY A SECOND
A.)
MINIMUM NAILING: MINIMUM NAILING SHALL BE PER 2013 CBC TABLE 2304.9.1.
ID
INSIDE DIAMETER
WWF
WELDED WIRE FABRIC
STORY HAVE BEEN INCLUDED IN THE DESIGN. THE OWNER SHALL BE ADVISED THAT EXISTING
INT
INTERIOR
W/
WITH
FOUNDATIONS MAY NOT BE STRUCTURALLY ADEQUATE AND SETTLEMENT, CRACKING, AND
B.)
LARGER MEMBERS: ALL FRAMING MEMBERS SPECIFIED IN THESE CALCULATIONS ARE
JST
JOIST
W/O
WITHOUT
OTHER PROBLEMS ASSOCIATED WITH EXISTING FOUNDATIONS ARE BEYOND THE SCOPE OF THIS
MINIMUMS, LARGER MEMBERS MAY BE SUBSTITUTED AT CONTRACTORS OPTION.
JT
JOINT
DESIGN. IF REVIEW OF THE EXISTING FOUNDATIONS IS REQUIRED, A GEOTECHNICAL ENGINEER
SHOULD BE CONTACTED TO DETERMINE THE EXTENT AND ADEQUACY OF THE EXISTING,
C.)
SHRINKAGE: CARE SHALL BE TAKEN TO ALLOW FOR EFFECTS OF SHRINKAGE WHICH COULD
UN -MODIFIED PORTIONS OF THE FOUNDATIONS.
CAUSE SETTLEMENT OF ROOF AND OR FLOORS AND COULD LEAD TO FAILURE OF ASSOCIATED
FRAMING MEMBERS. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT
FRAMING FROM THE EFFECTS OF SHRINKAGE.
3. CONCRETE / REINFORCING
D.)
ALL STRUCTURAL FRAMING MEMBER WITH EXTERIOR EXPOSURE SHALL BE PRESSURE TREATED
A)
CONCRETE SHALL HAVE A MINIMUM 28 DAY STRENGTH OF 2,500 PSI U.N.O.
OR BE OF MATERIAL THAT IS NATURALLY RESISTANCE TO DECAY.
C)
ALL CEMENT USED SHALL CONFORM TO ASTM C-150 AND SHALL BE TYPE II OR
ALKALI.
6-3 BEAM FRAMING:
TYPE III LOW
A.)
BUILT UP BEAMS: ALL BUILT UP, LAMINATED DOUBLE OR MULTIPLE 2X JOISTS AND BEAMS
D)
AGGREGATE SHALL CONFORM TO ASTM C-33 AND SHALL NOT CONTAIN MATERIALS WHICH ARE
SHALL BE NAILED TOGETHER WITH 16d NAILS AT 6" O.C., T&B U.N.O.
ALKALI REACTIVE AS DETERMINED BY ASTM C-227,289, AND 295. IF TEST DATA IS
UNAVAILABLE IN REGARDS TO ALKALI REACTIVE MATERIALS, PROVIDE CEMENT WITH A
B.)
DOUBLE JOISTS: PROVIDE DOUBLE FLOOR JOISTS UNDER PARTITION WALLS RUNNING PARALLEL
MAXIMUM ALKALI CONTENT LESS THAN 0.45% BY WEIGHT.
TO JOIST SPAN AND UNDER ALL LOCATIONS WHERE TUBS MAY BE LOCATED. ADEQUATE
SUPPORT SHALL BE PROVIDED FOR ALL OTHER EQUIPMENT OR FURNISHINGS WHICH
E)
CONCRETE EXPOSED TO FREEZING OR THAWING SHALL BE PROTECTED IN ACCORDANCE TO THE
MAY NOT BE SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING BUT NOT LIMITED TO: HOT
LATEST EDITION OF THE ACI 318.
WATER HEATER, STOVE, REFRIGERATOR, OVEN, FIRE PLACE ENCLOSURES, WOOD BURNING
STOVE, ETCETERA.
F)
SLABS ON GRADE SHALL BE PER THE CONTRACTOR. SUMMIT STRUCTURAL DESIGN RECOMMENDS
T
-
��
THE FOLLOWING AS A MINIMUM SLAB -ON -GRADE: AT GARAGE SLABS, USE 4" THICK S.O.G.
C.)
BLOCKING: PROVIDE SOLID BLOCKING IN JOIST FRAMING ABOVE ALL SUPPORTS
`
WITH #3 BARS AT 15" O.C. EACH WAY ABOVE MID -DEPTH OF SLAB OVER 2" SAND, OVER
F
e
r --
ES
MOISTURE BARRIER, OVER 4" AGGREGATE BASE. USE 3-1/2" SLAB WITH #3 AT 15" E.W. ABOVE`
MID -DEPTH OF SLAB, OR 6X6 WWF ABOVE MID -DEPTH OF SLAB WITH SAME SUB -SLAB BUILDUP
y
AT ALL OTHER AREAS.
Tc�
G)
SAW -CUT TOP 3/4" OF SLAB FOR CRACK CONTROL AT INTERVALS NOT TO EXCEED 10'-0" WHERE
SLAB IS REINFORCED, SAW CUT AT INTERVALS NOT TO EXCEED 7'-0" WHERE SLAB IS
UN -REINFORCED.
QRpFESS/pN9
�No. 75688'
* E . 6/ 0/16
J� CIV1�
q�FOF CALF 0�
3/25/16
THESE PLANS HAVE BEEN REVIEWED
FOR COMPLIANCE ONLY WITH THE
ATTACHED STRUCTURAL
CALCULATIONS
383 Rio Lindo Ave.
Suite 200
Chico, CA 95926
P. 530.592.4407
SummitChico.com
V) U
W �
Q
O
Z W Q
O
UZ)
Q oz
W
Q
a -Q
(n z
W �
U oQ
LJ z
U
5U
0
REVISIONS:
DATE: 3/25/16
SCALE: NTS
DRAWN BY: RKB
JOB NUMBER: 16-173
SHEET:
FASTENING SCHEDULE (TABLE 2304.9.1)
CONNECTION
FASTENING"
LOCATION
1. JOIST TO SILL OR GIRDER
3 - 8d COMMON (2 1/2" X 0.131')
F1.5
1'-6" 2'-6"
3-3"X0.131"NAILS
TOE NAIL
2'-0" 2'-0"
3 - 3" 14 GA. STAPLES
F2.5
2. BRIDGING TO JOIST
2 - 8d COMMON (2 1/2" X 0.131")
2 - 3" X 0.131' NAILS
TOE NAIL EACH END
2 - 3" 14 GA. STAPLES
3. 1' X 6" SUBFLOOR OR LESS TO EACH JOIST
2 - 8d COMMON (2 1/2" X 0.131')
FACE NAIL
4. WIDER THAN 1" X 6" SUBFLOOR TO EACH JOIST
3 - 8d COMMON (2 1/2" X 0.131')
FACE NAIL
5. 2" SUBFLOOR TO JOIST OR GIRDER
2 - 16d COMMON (3 1/2" X 0.162')
BUND AND FACE NAIL
6. SOLE PLATE TO JOIST OR BLOCKING
16d (3 1/2' X 0.135") AT 16" O.C.
3' X 0.131" NAILS AT 8' O.C.
TYPICAL FACE NAIL
3" 14 GA. STAPLES AT 12" O.C.
SOLE PLATE TO JOIST OR BLOCKING AT
3 - 16d (3 1/2" X 0.135') AT 16" O.C.
4 - 3' X 0.131" NAILS AT 16" O.C.
BRACED WALL PANELS
BRACED WALL PANEL
4 - 3" 14 GA. STAPLES PER 16"
7. TOP PLATE TO STUD
2 - 16d COMMON (3 1/2" X 0.162")
3 - 3" X 0.131" NAILS
END NAIL
3 - 3" 14 GA. STAPLES
8. STUD TO SOLE PLATE
4 - 8d COMMON (2 1/2" X 0.131')
4 - 3" X 0.131" NAILS AT 8" O.C.
TOE NAIL
3 - 3" 14 GA. STAPLES AT 12" O.C.
2 - 16d COMMON (3 1/2" X 0.162')
END NAIL
3-3"X0.131'NAILS
3 - 3" 14 GA. STAPLES
9. DOUBLE STUDS
16d (3 1/2' X 0.135") AT 24' O.C.
3" X 0.131" NAIL AT 8" O.C.
FACE NAIL
3" 14 GA. STAPLE AT 8" O.C.
10. DOUBLE TOP PLATES
16d (3 1/2" X 0.135") AT 16' O.C.
3" X 0.131" NAIL AT 12" O.C.
TYPICAL FACE NAIL
3" 14 GA. STAPLE AT 12" O.C.
DOUBLE TOP PLATES
8 - 16d COMMON (3 1/2" X 0.162" )
LAP SPLICE
12 - 3' X 0.131" NAILS
12 - 3" 14 GA. STAPLES
11. BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE
3 - 8d COMMON (2 1/2' X 0.131")
3-3"X0.131'NAILS
TOE NAIL
3 - 3" 14 GA. STAPLES
12. RIM JOIST TO TOP PLATE
8d (2 1/2" X 0.131') AT 6" O.C.
3" X 0.131" NAIL AT 6" O.C.
TOE NAIL
3" 14 GA. STAPLE AT 6" O.C.
13. TOP PLATES, LAPS AND INTERSECTIONS
2 - 16d COMMON (3 1/2" X 0.162")
3 - 3' X 0.131' NAILS
FACE NAIL
3 - 3" 14 GA. STAPLES
14. CONTINUOUS HEADER, TWO PIECES
16d COMMON (3 1/2" X 0.162')
16" O.C. ALONG EDGE
15. CEILING JOISTS TO PLATE
3 - 8d COMMON (2 1/2" X 0.131')
5 - 3" X 0.131" NAILS
TOE NAIL
5 - 3" 14 GA. STAPLES
16. CONTINUOUS HEADER TO STUD
4 - 8d COMMON (2 1/2" X 0.131')
TOE NAIL
17. CEILING JOISTS, LAPS OVER PARTITIONS
3 - 16d COMMON (3 1/2" X 0.162') MIN,
TABLE 2308.10.4.1
4 - 3" X 0.131' NAILS
FACE NAIL
4 - 3' 14 GA. STAPLES
18. CEILING JOISTS TO PARALLEL RAFTERS
3 - 16d COMMON (3 1/2" X 0.162') MIN,
TABLE 2308.10.4.1
4 - 3" X 0.131" NAILS
FACE NAIL
4 - 3" 14 GA. STAPLES
19. RAFTER TO PLATE
3 - 8d COMMON (2 1/2" X 0.131")
5 - 3' X 0.131" NAILS
TOE NAIL
5 - 3" 14 GA. STAPLES
20. 1' DIAGONAL BRACE TO EACH STUD AND PLATE
2 - 8d COMMON (2 1/2" X 0.131')
2 - 3" X 0.131" NAILS
FACE NAIL
3 - 3' 14 GA. STAPLES
21. 1" X 8' SHEATHING TO EACH BEARING
3 - 8d COMMON (2 1/2' X 0.131')
FACE NAIL
22. WIDER THAN 1" X 8" SHEATHING TO EACH BEARING
3 - 8d COMMON (2 1/2" X 0.131')
FACE NAIL
23. BUILT-UP CORNER STUDS
16d COMMON (3 1/2" X 0.162')
24" O.C.
3" X 0.131' NAILS
16" O.C.
3" 14 GA. STAPLES
16' O.C.
24. BUILT-UP GIRDER AND BEAMS
20d COMMON (4" X 0.192") AT 32" O.C.
FACE NAIL AT TOP AND
3" X 0.131" NAILS AT 24" O.C.
BOTTOMSTAGGERED ON
3" 14 GA. STAPLES AT 24" O.C.
OPPOSITE ENDS
2 - 20d COMMON (4' X 0.192')
FACE NAIL AT ENDS AND
3 - 3" X 0.131" NAILS
AT EACH SPLICE
3 - 3' 14 GA. STAPLES
25. 2' PLANKS
16d COMMON (3 1/2" X 0.162')
AT EACH BEARING
26. COLLAR TiE TO RAFTER
3 - 10d COMMON (3" X 0.148')
4 - 3" X 0.131" NAILS
FACE NAIL
4 - 3" 14 GA. STAPLES
27. JACK RAFTER TO HIP
3 - 10d COMMON (3" X 0.148")
4 - 3" X 0.131" NAILS
TOE NAIL
4 - 3" 14 GA. STAPLES
2 - 16d COMMON (3 1/2" X 0.162')
FACE NAIL
3 - 3" X 0.131" NAILS
3 - 3" 14 GA. STAPLES
28. ROOF RAFTER TO 2X RIDGE BEAM
2 - 16d COMMON (3 1/2" X 0.162")
3 - 3" X 0.131" NAILS
TOE NAIL
3 - 3" 14 GA. STAPLES
2 - 16d COMMON (3 1/2" X 0.162")
FACE NAIL
3 - 3" X 0.131" NAILS
3 - 3" 14 GA. STAPLES
29. JOIST TO BAND JOIST
3 - 16d COMMON (3 1/2" X 0.162')
4 - 3" X 0.131" NAILS
FACE NAIL
4 - 3" 14 GA. STAPLES
30. LEDGER STRIP
3 - 16d COMMON (3 1/2" X 0.162")
4 - 3" X 0.131' NAILS
FACE NAIL
4 - 3" 14 GA. STAPLES
31. WOOD STRUCTURAL PANELS AND PARTICLE BOARDS
1/2" AND LESS 60
SUBFLOOR, ROOF AND WALL SHEATHING (TO FRAMING)
2 3/8' X 0.113" NAIL'
19/32' TO 3/4" 8d OR 6d•
2 3/8" X 0.113" NAIL'
7/8" TO 1' 8d°
SINGLE FLOOR (COMBINATION SUBFLOOR-UNDERLAYM ENT
OR 8d'
BTO
FRAMING)
d'
3/4- AND LESS 6d' 60
7/8" TO 1' 8d°
1 1/8- TO 1 1/4- 1 Od' OR 8d-
32. PANEL SIDING (TO FRAMING)
1/2" AND LESS 64
5/8' 8d'
33. FIBERBOARD SHEATHING'
1/2' No. 11 GAGE ROOFING NAIL"
6d COMMON NAIL (2" X 0.113')
No. 16 GAGE STAPLE"
25/32' No. 11 GAGE ROOFING NAIL"
8d COMMON NAIL (2 1/2' X 0.131")
No. 16 GAGE STAPLE'
34. INTERIOR PANELING
1/4' 4d'
3/8" 6d`
a. common or Dox naps are permittee co oe useu except ..ilcla vul-loo
b. Nails spaced at 6 inches on center at edges, 12 inches at intermediate supports except 6 Inches at supports where spans are
48 inches or more. For nailing of wood structural panel and particleboard diaphragms and shear walls, refer to Section 2305. Nails
for wall sheathing are permitted to be common, box or casing.
c. Common or deformed shank (6d - 2" x 0.113'; 8d - 2 1/2" x 0.131"; 10d - 3' x 0.148')
d. Common (6d - 2" x 0.113"; 8d - 2 1/2" x 0.131"; 10d - 3' x 0.148')
e. Deformed shank (6d - 2" x 0.113"; 8d - 2 1/2" x 0.131"; 10d - 3" x 0.148")
f. Corrosion -resistant siding (6d - 1 7/8" x 0.106"; 8d - 2 3/8" x 0.128") or casing (6d - 2" x .099% 8d - 2 1/2" x 0.113')
nail
g. Fasteners spaced 3 Inches on center at exterior ridges and 6 inches on center at intermediate supports, when used as
structural sheathing. Spacing shall be 6 inches on center on the edges and 12 inches on center at intermediate supports for
nonstructural applications.
h. Corrosion -resistant roofing nails with 7/16 Inch diameter head and 1 1/8 inch length for 1/2 inch sheathing and 1 3/4 inch
length for 25/32 sheathing.
i. Corrosion -resistant staples with nominal 7/16 inch crown and 1 1/8 inch length for 1/2 inch sheathing and 1 1/2 inch length
for 25/32 sheathing. Panel supports at 16 inches (20 inches if strength axis in the long direction of the panel, unless otherwise
marked).
} Casing (1 1/2" x 0.080") or finish (1 1/2" x 0.072") nails spaced 6 inches on panel edges, 12 inches at intermediate supports.
k. Panel supports at 24 inches. Casing or finish nails spaced 6 inches on panel edges, 12 inches at intermediate supports.
I. For roof sheathing applications, 8d nails (2 1/2" x 0.113") are the minimum required for wood structural panels.
m. Staples shall have a minimum crown width of 7/16 inch.
n. For roof sheathing applications, fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports.
o. Fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports for subfloor and wall sheathing and 3 inches
on center at edges, 6 inches at intermediate supports of roof sheathing.
p. Fasteners spaced 4 inches on center at edges, 8 inches at intermediate supports.
TYPICAL FASTENING SCHEDULE 1a
NO SCALE SD
3" CL
3"
3" C
FTG TYPE PER PI
-I
THICKNESS
R
A
N
�e_
FORCE WITH #4
i" O.C. E.W.
TYPICAL SPREAD FOOTING SCHEDULE 7
NO SCALE S D 1
ROOF PLY AND
NAILING PER PLAN-\
V-3" MAX 2'-0"
.N.
FASCIA BY E.N.
OTHERS
2X4 FLAT
OUTLOOKER AT
NOTE: 24" O.C., NOTCH
CONTRACTOR SHALL VERIFY NOTCH TOP CHORD TO
DEPTH AND LOCATION WITH TRUSS I SEAT OUTLOOK R
MFR. PRIOR TO CUTTING.
SHEAR ENTIRE WALL WITH 1/2" THICK
APA RATED SHEATHING WITH 8d COMMON •'
AT 6" O.C. EDGES, 12" O.C. FIELD
i
16d AT 12" O.C.
GABLE END •
TRUSS BY OTHERS . •:
3) 16d TOENAILS •N•
•
•
2X6 BRACE AT
4'-0" O.C. WITH
(5) 16d NAILS
EACH END
2X BLOCKING AT 4'-0" O.C.,
T&B, (3) 12d T.N. EA. END
T T 2X6 AT 4'-0" O.C.
NOTCHED AROUND
TRUSS MEMBERS
BEAM PER PLAN WITH (4) 16d
TOENAILS BOTT.
AND (3) 16d TOP
E.N!"'
NOTE: MAX CEILING DEAD LOAD =2 PSF.
TYPICAL GABLE END TRUSS DETAIL
NO SCALE
SD1
ROOF PLY AND
NAILING PER PI
RBC CUP PER SHEAR
WALL SCHEDULE,
OTHERWISE 4'-0" O.C., TYP.
E.N
SOLID BLOCKING
H2.5T EA. TRUSS
FASCIA BY OTHERS
BEAM PER PLAN -
ROOF TRUSSES
BY OTHERS
NOTE: MAX CEILING DEAD LOAD =2 PSF.
TYPICAL EAVE DETAIL 6
NO SCALE SD1
BEAM PER PLAN
HGA10 CUP BEAM
LSTA18 STRAP. BEND
OVER FACE OF OUTSIDE
BEAM AS REQ'D
NOTES:
1.) CORROSION PROTECTION BY OTHERS.
2.) COLUMN CAP BELOW PER PLAN (NOT SHOWN FOR CLARITY).
TYPICAL CORNER BEAM DETAIL
NO SCALE
OH 5
SD1
BEAM PER PLAN
I / I
3/16 V `-' I `-POST CAP
PER PLAN
11/4" CAP PLATE
s I I
j I I HSS POST /
PER PLAN
BEAM PER PLAN
PER PLAN
nr♦u Mr -n n" •u
.TE
=R PLAN
NOTES:
1.) CORROSION PROTECTION BY OTHERS.
2.) FIELD WELD AND OBTAIN SPECIAL INSPECTION AS REQUIRED.
MID -POST COLUMN CAP DETAIL 3
NO SCALE SD1
HSS COL. PER
PLAN,
CENTERED
OVER FOOTING
2" NON -SHRINK
GROUT 5000 PSI MIN.
(E) FTG PER PLAN
#4 AT 20" O.C. EACH
WAY, TYP. oa
EMBED 6" INTO (E)
FTG, TYP WITH
SET -XP EPDXY.
INSTALL PER MFR.
RECOMMENDATIONS.
LOCATE AND AVOID/V J,
ALL REINFORCING
PRIOR TO DRILLING
BASE PLATE 1/2- THICK X 12"
SQ. WITH (4) 1/2" DIA. THREADED
RODS WITH 12" MIN. EMBED IN
SET -XP EPDXY IN (N) OR (E) FTG
BELOW. USE DBL NUTS FOR
LEVELING. INSTALL PER MFR.
RECOMMENDATIONS. LOCATE AND
AVOID ALL REINFORCING PRIOR TO
DRILLING
1
1/2- TYP
I
(E) SLAB -ON -GRADE
PER PLAN
pll w
II
Li•o .o
OP O C5 O 18"
=III- 3" CLR
IIII''
18" (N) FTG PER PLAN
#4 AT 6" O.C. EACH WAY, TYP.
EMBED 6" INTO (E) FTG WHERE REQ'D
WITH SET -XP EPDXY. INSTALL PER MFR.
RECOMMENDATIONS. LOCATE AND AVOID
ALL REINFORCING PRIOR TO DRILLING
S NOTES:
SD1 1.) CORROSION PROTECTION BY OTHERS.
2.) FIELD WELD AND OBTAIN SPECIAL INSPECTION AS REQUIRED.
HSS POST FOUNDATION DETAIL
12'-1" MAX.
ABOVE TOP
OF FTG
LSTA36 STRAP WRAPPED
AROUND BEAM WITH
STRAP ENDS AT BOTTOM
SIDE. INSTALL TAUT
CCOQ COLUMN
CAP, OR EQUAL
CP, TYP EACH END OF BRACE
NOTES:
1.) BRACE FRAMING AS REQUIRED DURING CONSTRUCTION.
2.) PERPENDICULAR BRACE NOT SHOWN FOR CLARITY.
3.) WEATHERPROOFING, FLASHING AND CORROSION PROTECTION BY OTHERS.
4.) ADDITIONAL FRAMING BY OTHERS NOT SHOWN FOR CLARITY. SEE PLANS
AND DETAILS BY OTHERS FOR ADDITIONAL INFORMATION.
5.) PRE -DRILL SDS SCREW HOLES 5/32" AS REQUIRED TO AVOID SPLITTING.
6.) FIELD WELD AND OPTAIN SPECIAL INSPECTION AS REQUIRED.
TYPICAL KNEE BRACE DETAIL
NO SCALE
NO SCALE
HSS COL. PER
PLAN,
CENTERED
OVER FOOTING
2" NON -SHRINK
GROUT 5000 PSI MIN.
(E) SLAB -ON -GRADE
PER PLAN\
2
SD1
BASE PLATE 1/2" THICK X 12"
/SQ. WITH (4) 1/2" DIA. THREADED
RODS WITH 12" MIN. EMBED IN
SET -XP EPDXY IN (N) FTG BELOW.
USE DBL NUTS FOR LEVELING.
INSTALL PER MFR.
RECOMMENDATIONS. LOCATE AND
AVOID ALL REINFORCING PRIOR TO
DRILLING
1 1/2" TYP
II II
•O .O •O .
O0.Oo°o. O
a-a� O�Oo°�. 18"
I-
1-11 I_ 3" CLR
(N) FTG PER PLAN IIIIIII
PER PLAN
#4 AT 6" O.C. E.W. e
NOTES:
OATEy
1.) CORROSION PROTECTION BY OTHERS. ----i�`jYJ
2.) FIELD WELD AND OBTAIN SPECIAL INSPECTION AS REQUIRED. i1
4 HSS POST FOUNDATION DETAIL
SD1 NO SCALE
`�• "
Q OFESS/0N9
K.
�-A Z
rNo. 75688'
* E . 6/ 0/16
C/V1�
gTFOF CALF 0�
3/25/16
THESE PLANS HAVE BEEN REVIEWED
FOR COMPLIANCE ONLY WITH THE
ATTACHED STRUCTURAL
CALCULATIONS
383 Rio Lindo Ave.
Suite 200
Chico, CA 95926
P. 530.592.4407
SummitChico.com
V)
ssss�
Q
W U
0 G
Q
sssssJ =
W :D
O
UD
Oz
�z W
U>
M Q
:D (.%3 Z
W NJ
Q
�-
EL- zz
U
sssssss�
(V
O
U
r
REVISIONS:
DATE: 3/25/16
-SCALE: NTS
DRAWN BY: RKB
_JOB NUMBER: 16-173
SHEET:(,SD 1
-4 .4,
.
FOOTING SCHEDULE
FOOTING TYPE
DIMENSION A DIMENSION B, U.N.O.
THICKNESS, U.N.O.
F1.5
1'-6" 2'-6"
18"
F2
2'-0" 2'-0"
18"
F2.5
2'-6" 2'-6"
18"
TYPICAL SPREAD FOOTING SCHEDULE 7
NO SCALE S D 1
ROOF PLY AND
NAILING PER PLAN-\
V-3" MAX 2'-0"
.N.
FASCIA BY E.N.
OTHERS
2X4 FLAT
OUTLOOKER AT
NOTE: 24" O.C., NOTCH
CONTRACTOR SHALL VERIFY NOTCH TOP CHORD TO
DEPTH AND LOCATION WITH TRUSS I SEAT OUTLOOK R
MFR. PRIOR TO CUTTING.
SHEAR ENTIRE WALL WITH 1/2" THICK
APA RATED SHEATHING WITH 8d COMMON •'
AT 6" O.C. EDGES, 12" O.C. FIELD
i
16d AT 12" O.C.
GABLE END •
TRUSS BY OTHERS . •:
3) 16d TOENAILS •N•
•
•
2X6 BRACE AT
4'-0" O.C. WITH
(5) 16d NAILS
EACH END
2X BLOCKING AT 4'-0" O.C.,
T&B, (3) 12d T.N. EA. END
T T 2X6 AT 4'-0" O.C.
NOTCHED AROUND
TRUSS MEMBERS
BEAM PER PLAN WITH (4) 16d
TOENAILS BOTT.
AND (3) 16d TOP
E.N!"'
NOTE: MAX CEILING DEAD LOAD =2 PSF.
TYPICAL GABLE END TRUSS DETAIL
NO SCALE
SD1
ROOF PLY AND
NAILING PER PI
RBC CUP PER SHEAR
WALL SCHEDULE,
OTHERWISE 4'-0" O.C., TYP.
E.N
SOLID BLOCKING
H2.5T EA. TRUSS
FASCIA BY OTHERS
BEAM PER PLAN -
ROOF TRUSSES
BY OTHERS
NOTE: MAX CEILING DEAD LOAD =2 PSF.
TYPICAL EAVE DETAIL 6
NO SCALE SD1
BEAM PER PLAN
HGA10 CUP BEAM
LSTA18 STRAP. BEND
OVER FACE OF OUTSIDE
BEAM AS REQ'D
NOTES:
1.) CORROSION PROTECTION BY OTHERS.
2.) COLUMN CAP BELOW PER PLAN (NOT SHOWN FOR CLARITY).
TYPICAL CORNER BEAM DETAIL
NO SCALE
OH 5
SD1
BEAM PER PLAN
I / I
3/16 V `-' I `-POST CAP
PER PLAN
11/4" CAP PLATE
s I I
j I I HSS POST /
PER PLAN
BEAM PER PLAN
PER PLAN
nr♦u Mr -n n" •u
.TE
=R PLAN
NOTES:
1.) CORROSION PROTECTION BY OTHERS.
2.) FIELD WELD AND OBTAIN SPECIAL INSPECTION AS REQUIRED.
MID -POST COLUMN CAP DETAIL 3
NO SCALE SD1
HSS COL. PER
PLAN,
CENTERED
OVER FOOTING
2" NON -SHRINK
GROUT 5000 PSI MIN.
(E) FTG PER PLAN
#4 AT 20" O.C. EACH
WAY, TYP. oa
EMBED 6" INTO (E)
FTG, TYP WITH
SET -XP EPDXY.
INSTALL PER MFR.
RECOMMENDATIONS.
LOCATE AND AVOID/V J,
ALL REINFORCING
PRIOR TO DRILLING
BASE PLATE 1/2- THICK X 12"
SQ. WITH (4) 1/2" DIA. THREADED
RODS WITH 12" MIN. EMBED IN
SET -XP EPDXY IN (N) OR (E) FTG
BELOW. USE DBL NUTS FOR
LEVELING. INSTALL PER MFR.
RECOMMENDATIONS. LOCATE AND
AVOID ALL REINFORCING PRIOR TO
DRILLING
1
1/2- TYP
I
(E) SLAB -ON -GRADE
PER PLAN
pll w
II
Li•o .o
OP O C5 O 18"
=III- 3" CLR
IIII''
18" (N) FTG PER PLAN
#4 AT 6" O.C. EACH WAY, TYP.
EMBED 6" INTO (E) FTG WHERE REQ'D
WITH SET -XP EPDXY. INSTALL PER MFR.
RECOMMENDATIONS. LOCATE AND AVOID
ALL REINFORCING PRIOR TO DRILLING
S NOTES:
SD1 1.) CORROSION PROTECTION BY OTHERS.
2.) FIELD WELD AND OBTAIN SPECIAL INSPECTION AS REQUIRED.
HSS POST FOUNDATION DETAIL
12'-1" MAX.
ABOVE TOP
OF FTG
LSTA36 STRAP WRAPPED
AROUND BEAM WITH
STRAP ENDS AT BOTTOM
SIDE. INSTALL TAUT
CCOQ COLUMN
CAP, OR EQUAL
CP, TYP EACH END OF BRACE
NOTES:
1.) BRACE FRAMING AS REQUIRED DURING CONSTRUCTION.
2.) PERPENDICULAR BRACE NOT SHOWN FOR CLARITY.
3.) WEATHERPROOFING, FLASHING AND CORROSION PROTECTION BY OTHERS.
4.) ADDITIONAL FRAMING BY OTHERS NOT SHOWN FOR CLARITY. SEE PLANS
AND DETAILS BY OTHERS FOR ADDITIONAL INFORMATION.
5.) PRE -DRILL SDS SCREW HOLES 5/32" AS REQUIRED TO AVOID SPLITTING.
6.) FIELD WELD AND OPTAIN SPECIAL INSPECTION AS REQUIRED.
TYPICAL KNEE BRACE DETAIL
NO SCALE
NO SCALE
HSS COL. PER
PLAN,
CENTERED
OVER FOOTING
2" NON -SHRINK
GROUT 5000 PSI MIN.
(E) SLAB -ON -GRADE
PER PLAN\
2
SD1
BASE PLATE 1/2" THICK X 12"
/SQ. WITH (4) 1/2" DIA. THREADED
RODS WITH 12" MIN. EMBED IN
SET -XP EPDXY IN (N) FTG BELOW.
USE DBL NUTS FOR LEVELING.
INSTALL PER MFR.
RECOMMENDATIONS. LOCATE AND
AVOID ALL REINFORCING PRIOR TO
DRILLING
1 1/2" TYP
II II
•O .O •O .
O0.Oo°o. O
a-a� O�Oo°�. 18"
I-
1-11 I_ 3" CLR
(N) FTG PER PLAN IIIIIII
PER PLAN
#4 AT 6" O.C. E.W. e
NOTES:
OATEy
1.) CORROSION PROTECTION BY OTHERS. ----i�`jYJ
2.) FIELD WELD AND OBTAIN SPECIAL INSPECTION AS REQUIRED. i1
4 HSS POST FOUNDATION DETAIL
SD1 NO SCALE
`�• "
Q OFESS/0N9
K.
�-A Z
rNo. 75688'
* E . 6/ 0/16
C/V1�
gTFOF CALF 0�
3/25/16
THESE PLANS HAVE BEEN REVIEWED
FOR COMPLIANCE ONLY WITH THE
ATTACHED STRUCTURAL
CALCULATIONS
383 Rio Lindo Ave.
Suite 200
Chico, CA 95926
P. 530.592.4407
SummitChico.com
V)
ssss�
Q
W U
0 G
Q
sssssJ =
W :D
O
UD
Oz
�z W
U>
M Q
:D (.%3 Z
W NJ
Q
�-
EL- zz
U
sssssss�
(V
O
U
r
REVISIONS:
DATE: 3/25/16
-SCALE: NTS
DRAWN BY: RKB
_JOB NUMBER: 16-173
SHEET:(,SD 1
-4 .4,
.
� (1'I
- _._�_T � _.._____.�..,.. ----_ _ -_ - _ _ --- -- _ - � � _ � _ .__-
f