Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B16-0650 000-000-000
�4 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A MOUNTING SYSIEU: AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. PART TO OTHERS OUTSIDE THE RECIPIENTS BLDG BUILDING 2. THIS SYSTEW HAS NO BATTERIES, NO UPS. MODULES CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN FRONIUS # Primo 3.8 EGC ' EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, FSB FIRE SET—BACK A SIGN WILL BE PROVIDED WARNING OF THE GALV GALVANIZED HAZARDS PER ART. 690.17. GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN - (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY NEUT NEUTRAL UL LISTING. NTS NOT. TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL—LISTED LOCATION PROVIDED BY THE PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING POI POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER VICINITY MAP INDEX Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET PV2 PROPERTY PLAN PV3 SITE PLAN PV4 . STRUCTURAL VIEWS LICENSE GENERAL NOTESy - PV5 UPLIFT CALCULATIONS PV6 THREE LINE DIAGRAM CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 X r �� ! Cutsheets Attached C-10 CALIFORNIA BUILDING CODE, 2013 CALIFORNIA PLUMBING CODE, AND THE 2013 CALIFORNIA RESIDENTIAL CODE. ' 2. ALL ELECTRICAL WORK SHALL COMPLY WITH ; THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY MODULE GROUNDING METHOD: ZEP SOLAR THE 2013 CALIFORNIA ELECTRIC CODE.. AHJ: Butte County UTILITY: Pacific Gas and Electric Company CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB -9596155 0 0 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSIEU: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZS Comp V4 PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES THE SALE AND USE OF THE RESPECTIVE (10) REC # REC260PEZ SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PERMISSION OF SOLARCITY INC FRONIUS # Primo 3.8 BOB TREMAIN 852 CLEVELAND AVENUE CHICO, CA 95928 APN: 005-400-003 Bob tremain RESIDENCE 2.6 KW PV ARRAY PAGE NAME: COVER SHEET REV BY DATE COMMENTS REV A NAME DATE COMMENTS s s s s s s s s Killian Madden SHEET: RM. DATE- PV ATEPV 1 4/2/2016 =;SolarCit . 3055 CleaMew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (668)—SOL—aTY (765-2489) wmeolaraityoan - I ek - - I i Existing Carport- 375 sqR -. -T LltEI DNIVEWRY 662 aeodm Avme - - - i PROPERTY PLAN N Scale: 1" = 20'-0' W 0 20' 40' E S CONFlDENTIAL —THE INFORMATION HEREIN CONTAINED MALL NOT BE USED FOR THE q8 NUMBER JB -9596155 0 0 PREMISE OWNER: BOB TREMAIN DESCR[PTIOk Bob tremain RESIDENCE DESIGk Killian Madden ��% ; ``�,�SolarCity MOUNTING SYSTEM: ZS Comp V4 BENEFIT OF ANYONE EXCEPT SOLARgTY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 852 CLEVELAND AVENUE 2.6 KW PV ARRAY � .t� PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION. EXCEPT IN CONNECTION WITH C I I I C O t CA 95928 MODULES 3055 Cher Way CA THE SALE AND USE OF THE RESPECTIVE (10) REC # REC26-OPEZ PN: 005-400-003Son PAGE NAME SHEET: REV DATE INVERTER: FRONIUS # Primo 3.8 SOLARCITY EQUIPMENT, BITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. PROPERTY PLAN PV 2 4/2%2016 T:(650) 638-1028 (650) 638-1029 (BBB)-SOL-CrIY (765-2469) www.solmdty.corn PITCH: 22 ARRAY PITCH: 22 MP1 AZIMUTH: 81 ARRAY AZIMUTH: 81 MATERIAL: Comp Shingle STORY: 1 Story • , 3' FS8 I A LEGEND Front Of House mI Q (E) UTILITY METER & WARNING- LABEL INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS DC JUNCTION/COMBINER BOX & LABELS I • Inv M O 0 DISTRIBUTION PANEL &LABELS 3 F B� LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR — GATE/FENCE r Q HEAT PRODUCING VENTS ARE RED INTERIOR EQUIPMENT IS DASHED -• L _"J ' • .n n- SITE PLAN N _ (E) DRIVEWAY Scale:1/16" = 1' W E 01' 16' 32' g CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT USED FOR THE ER JB-9596155 00 PREMISE OWNER BOB TREMAIN DESMPTION: Bob tremain RESIDENCE DESIGN: Killion Madden SolarCity EXCEPTYONE No SMALL IEFIT OF T"BE DISCLOSEDINWHWHOLE ORCITY CINMOUNTING srsIEE1 omp V4 852 CLEVELAND AVENUE 2.6 KW PV ARRAY '"c PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH [:FROONIUS CHICO CA 95928 s THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT. WITHOUT THE WRITTEN REC # REC260PEZ PAGE NAME SHS'�DA1E'T:(650) 3055 aeoNe. WDy Son Mateo, CA 94402 638-1028 F:(65o) 678-1029 PERMIssoN of soLARaTY INC # Primo 3.8 SITE PLAN PV 3. 4/2/2016 1 (888)—SOL-aTr (765-2489) wmaolarRyoom A SIDE VIEW OF MPI NTS MPI . X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 72" 24." LOCATE RAFTER, MARK HOLE PORTRAIT 48° 20"' TOP CHORD 2X4 @ 24 OC BOT CHORD 2X4 @24" OC ROOF A2'I 81 PITCH 22 ARRAY AZI 81 PITCH 22 STORIES: 1 Comp Shingle PV MODULE 5/16"x4.5" HANGER BOLT WITH 5/16" NUT ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT V4 (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL HANGER BOLT (2-1,/2" EMBED, MIN) (E) RAFTER INSTALLATION ORDER LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT (4) CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED MALL NOT BE USED FOR THE JOB NUMBERJ B- 9 5 9 615 5 0 0 I DVIM BOB TREMAIN HOLE. - --------- -------- 2 () ATTACH COMP MOUNT TO 852 CLEVELAND AVENUE (3) SolarCity. RAFTER USING HANGER BOLT. PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES CHICO, CA 95920 BELL SSS DOWNWARD, ORGANIZATION. EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE COMPRESSING AND RELEASING (1) (3) THE SEALANT WHICH SPREADS (2) PAGE NAME SHEET: REV. DATE: EVENLY OVER THE ROOF PERMISSION OF SONARgTY INC. FRONIUS # Primo 3.8 STRUCTURAL VIEWSP PENETRATION: 4 2 2016 V 4 / / ST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT ON TOP (4) OF HANGER BOLT & SECURELY FASTEN WITH 5/16" NUT. STANDOFF S1 i Scale: 11/2" = 1' CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED MALL NOT BE USED FOR THE JOB NUMBERJ B- 9 5 9 615 5 0 0 I DVIM BOB TREMAIN DESCRIPTION: Bob tremain RESIDENCE IIESIGN: Killian Madden BOF ANYONE EYCEPT SOLARCITY ENEFITC IT BE DISCLOSED IN WHOLE OR NOR SH Y01N1°'G SYSTEM ZS Comp V4 852 CLEVELAND AVENUE 2.6 KW PV ARRAY SolarCity. PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES CHICO, CA 95920 ORGANIZATION. EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (10) REC # REC260PEZ 3055 qemAew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN�� PAGE NAME SHEET: REV. DATE: Son T:(650) 638-1028, CA 94402 (650) 838-1029 PERMISSION OF SONARgTY INC. FRONIUS # Primo 3.8 STRUCTURAL VIEWSP 4 2 2016 V 4 / / (M) -SOL -CITY (765-2489) wn..edmdtyoom UPLIFT CALCULATIONS 04.02.2016 r ■ Version #55.3 PV System structural c,,SolarClty Design Software Project Information & Table Of Contents Risk Category__^u_ ``, "!� SolarCity. Wiv II PV^System Type ---- ... _- - _ _ S rC1ty SleekNlouot'TM --�— INVER1ER FRONIUS # Primo 3.8 Comp Roof L`" ers.'ofCom Roofin -- Comp Roof _ 2 MRoof Slope Rafter - ! adn 22° 24" O C- PV'System Module: Orientation �_ PV`Module Area_ Landscape and Portrait PV Module. Width 39" PV Module Length.------.__—_ —_� 66R__.. __-- Sta idoff Attachment Hardware _ Comp_ Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load _ pg _ 0.0 Psf ASCE Table 7-1 Surrounding �f Snow- Roof Snow Over PV Modules O:O,psf ; AS(f Eg;_7.41 ASCE Eq. 7.4-1 0.0 Psf Wind Desi n Criteria Wind Wind Design_:Code _ beggn' Method i ASCE 7=10 Partially%Fully Endosed Method _ Basic Wind Speed _ V 110 mph _ ___fig Z6 1A ExpoWf,q. Gategory, Roof.Style-u . C Section 26T - a9..ao.4za/s/C-5A __. __— _ Gable Roof _ Mean gggf _tight h __ _` 15, ft Sec4on 26;2 Effective Wind Area 1 Module A 17.8 sf• IBC 1509.7.1 Wind. Pressure Ca1W1;Aion,Coefficients Wind Pressure Exposure TopographicFaLtor -__- Kz_ — -KitSection 0.85 ------ Table 330.371 26f3✓ , Wind Directionalltty Factor___ ._.__ Kd � 0.85 _ ...Section 266-1 Im- rtance�Fador I NA Veloaty, Pressure 4h qh: = 0.00256 (Kz) (Kzt) (Kd) (V^2) 22.4 Equation 30:3=1 Ext; Pressure Coeffident (Up) Ext Pressureeffi&e Con -t Down -0:88 Fig. 33o 4-2A/e/c-sA/e; G .. , Dowri Design Wind Pressure P P = gh GC Equation 30.4-L N►indrPressure UP _;P(qP)— -19.6_Psf Wind Pressure Down` down 16.0 Allowable Standoff 'Spacings X -Direction Y-UirecfiOn Max Allowable Standoff %acing_ Max Allowable,aTitilever Landscape _ 72" 39" Landscape 24" NA Standoff.Conft uration Landscape Not-Sta gered Max_StandoffTributary,Area: __ Trfb, ___ _ 20sf __ PV Assembly_Dead Load T Net 11Vind lJpli(i at Standgtf W -PV ^3 psf� 196:lbs r T -a tuai Uplift Capadty of Standoff T -allow 50016s Standoff Demand Ca ' DM 39.3% Max Allowable Standoff Spadng_ Portrait 48" 66" Max Allowable Cantilever _Portrait_ 20" NA: Standoff Confi uration Portrait Not- gered MazStandoffTd-kq ry_Area _ Trtb. _ 22sf' _ PV Assembly Dead Load W PV 3 psf P1eCWind Uplift at_Starrdoff° _ T_actlal 220;ibs Uplift Ca._, of Standoff Tallow _500 lbs Standoff Derharfd/Capacity D131Z 44.01Yo CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOIARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC JOB NUMBER:J B-9596155 OO MISE OWNER: Dmpnm BOB TREMAIN Bob tremain RESIDENCE 8552 CLEVELAND AVENUE 2.6 KW PV ARRAY CHICO CA 95928 , PAGE NAME UPLIFT CALCULATIONS DESIM Killian Madden ``, "!� SolarCity. Wiv MOUNMG SYSIEIt ZS Comp V4 MaoutEs (10) REC # REC260PEZ 3os5 Cleanie. Way CA 94402 T:(650) 638-102Son 6 (650) 638-1029 (888) -SOL -cm (765-2489) m...edmcity.can DATE P V 5 4/2/2016 INVER1ER FRONIUS # Primo 3.8 GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE OND (N) #6 GEC TO (E) UFER AT PANEL WITH IRREVERSIBLE CRIMP Panel Number: SMB10(12-24)FB Meter Number.1007884450 Inv 1: DC Ungrounded INV 1 — (1) FRONIUv Primo 3.8 LABEL: A AFCI Inver; 3800W, 240V, 977%w/ Antenna — (10) REV ## REC260PEZ PV tvlodule; 26060 W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled CA # 888104 C-10 INV 2 Overhead Service Entrance Voc: 37.8 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER 125A CENTER—FED MAIN SERVICE PANEL �E E� 100A/2P MAIN CIRCUIT BREAKER Inverter L PAR 100A/2P 2 FRONIUS Primo 3.8 (E) LOADS • L1 • L2 13 20A/2P_ _ (0 N ECC DC+ 1 DC+ _ _ 13) ___-------- 0' 4 A r I 'N DG Dc MP 1: 1x10 e r--------------------------------- I I GEC , ' N — -- —GEC ----� TO 120/240V SINGLE PHASE UTILITY SERVICE I I I Voc* = MAX VOC AT MIN TEMP POI (1 )UBreakerBlZmsco QC Series 20A%2�Sp MAKER AC DC 1 AWG g10. THWN-2, Block (1) AWG BIO, THWN-2, Red — 1 AWG B6, Solid Bare Copper GEC (2)AWG BIO, PV Wire, 60OV, Black VoC* = 414.74 VDC Isc = 9.01 ADC O(1) AWG BIO, THHN/THWN-2, Green EGC Vmp = 307 VDC Imp= 8.5 ADC LOLL (1)AWG BIO, THWN-2, White NEUTRAL VmP =240 VAC IMP=15.8 AAC (1)Conduii Kit. 3/4'• EMT. .......-(1)AWG BIO, THWN7Z.gr eo.. TPC .... -(1)Cond4 Kit:. 3/47. EMT.......... CONFIDENTIAL — THE INFORMATION HEREIN -0 NUMBER JB -9596155 00 PRE105E OWNER DESCRIPTION. DESIGN: CONTAINED SHALL NOT USED FOR THE BOB TREMAIN Bob tremain RESIDENCE Killian Madden M"' C SY p ' ZS Comp V4 EXCEPT NOR SHAM I17 BT OF E of LOSEI�OLIEE ORCITY INIFRONIUS 852 CLEVELAND AVENUE 2.6 KW PV ARRAY ���SolarCity A. PART HERS OUTSIDE THE RECIPIENTS CHICO CA 95928 MODULES. IZ TI ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (10) REC # REC260PEZ � 3055 CIearview Way SHEEL• REV: DATE SOLARg1Y EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME San Mateo, CA 94402 T:(650) 638-1028 R(650) 638-1029 INVERTER PERMISSION OF SMENT,WI INC # Primo 3.8 THREE LINE DIAGRAM PV 6 4/2/2016 (888) -SOL -CITY (765-2489) www.solarcity.corn ` + ^ •' ' ,` •• � jam. � ,. ,` - •. ..• -, �.1 � -.r � 1. Y. . 4 I� POWERWARNING: PHOTOVOLTAIC ,I Label Location: Label Location: + Label Location: f (C)(IC)(CB) �` - 4. (AC) � � (DC)(INV)(CB) � `¥ ra Per Code: DISCONNECT FOR 'j Per Code: r .A.. . CRC R331.2,. OPERATION ELECTTHE •CONDUCTORS •F THIS - HAZARD CEC 690.35(F) » , Label Location: PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN - • • • (DC) (INV) » - . ' - • . . . INVERTER IS r . }. DISCO Per Coder '� UNGROUNDED - ' CEC 690.14:C..2 K . - Label Location: (DC) ` 4 , , 'eYWARNING _ • f w Per Code:ELECTRIC r �' Label Location:, - . • • • . -. CEC 690.17J. _� _ ti� '� ` .. • ;,, " MAXIMUM - • (DC) (INV),., r' • : • . POINT _ Per Code: ti .-. MAXIMUM CEC 690.53. '� IN THE -EN POSITIONPOINT VOLTAGE (Vmp) 4 MAXIMUM SYSTEM VOLTAGE (Voc)m Label L`ocatlon . `. `, a • ' f _ %....� y r , f "� (POIWARNING ). P Per Code '• INVERTER • • ~ v UT •-UT CEC 705.112.D.7CONNECTI. R Label Location: . • NOT RELOCATE WARNING'(DC) (CB) a • - DEVICE Per Code SHOCKELECTRICAL HAZARD . •• • CEC 690.17,,' • 5 ,�' - ; TERMINALS ON BOTH LINE AND ••. SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: 4 3 • • . .t • • • -• • (POI)ALWAYS PRESENT WHEN INTERC SOLAR•.. * = • • Per Code: ING: ELECTRIC SHOCK EXPOSED • °. . _ • -.. • • • CEC 690.54; CEC 690!17HAZ r TERMINALS. TERMINALS • BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label Location DE-ENERGIZEDE-ENERGIZE BOTH SOURCEY. BREAKER.- f WARNING(INV) .••IN SOURCE Per Code:. _ ,.•.. .. �,, j' IFA GROUNDELECTRIC • INDICATED• -. CEC 690.5(C) •-MAXIMUM AC - FAULT IS »x NORMALLY GROUNDED MAXIMUMAC 1 OPERATING VOLTAGE CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: Label Location: (D) (POI) h. PHOTOVOLTAIC (AC) (POI) Per Code: � �, - r (AC): AC Disconnect PHOTOVOLTAIC SYSTEM DISCONNECT Per Code: ' ' • CEC 690.64.B.4 r � .:; ._ (C): Conduit CEC 690.14.C.2 w. �.R "(CB): Combiner Box-' *' _ (D): Distribution Panel : F,,.. (DC): DC Disconnect Label Location: Label Location: • .(IC): In Run Conduit (AC) (POI) ' • (POI) r r (INV): Inverter With Integrated DC Disconnect MAXIMUM AC(LC): Load Center • - Per Code: r DUAL POWER • Per Code: .' (M): Utility Meter ` MAXIMUM AC CEC 690.54 SECOND • CEC 705.12.D.7 • - •PHOTOVOLTAICa - .' ' + (P,OI): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED , r r .�r �I 3055 aearvlew way IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Label Set f ` ,, !������ T:(650) 638 - San 1028 F (650638 1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE ., . /� otarc. ii (888}SOL-CrrY (765-2989) www.solarary.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ` + . ' F' . A - , -REC PEAK ENERGY Z LINK SERIES b I. � 1 4 .a r EL CTRICALDATA@STC ' Nominalpower _ .t WP),_ REC26OPEZ 260 _..,,. ,. _m . _ ... ,Watt Class Sorting -(Wp) ....... ........ +/-5 .. .................. Nominal Power Vol tage-V (V) .. 30.7 - :Nominal Power Current -!r• (A) ,,8.50 A - , -REC PEAK ENERGY Z LINK SERIES b I. � 1 All measurements in inches 5 EL CTRICALDATA@STC ' Nominalpower _ .t WP),_ REC26OPEZ 260 _..,,. ,. _m . _ ... ,Watt Class Sorting -(Wp) ....... ........ +/-5 .. .................. Nominal Power Vol tage-V (V) .. 30.7 - :Nominal Power Current -!r• (A) ,,8.50 OpenCircuitVoltage-V«(V)37.8 .......... ...................... Short Circuit Current - Is, (A)9.01 rF Panel Efficiency(%) „ ..... ....... 15.8 . ....-.........-.........., ........................ Theelectrical characteristics are within •/•10%of the indicated values of h�ec••V and Pp„at standard Test conditions (STC). cell 770F • ' Values at standard test conditions STC (airmass AM 1.S, irradiance 1000 W,F. , temperature (25'C)). ' At low irradiance of 200 W/mr (AM 1.5 & cell temperature 77'F 125'C)) at least 97% of the STC panel efficiency will be achieved. ELECTRICAL DATA @ NOCT Nominal Power -Pty„ (Wp) REC26OPEZ 197 Nominal Power Voltage -V� (V) 29.0 Nominal Power Current - I,(A) 6.81 _. Open Circuit Voltage - Vo, IV) _,,..,..,v,...__........r.... ,. 35.7 Silo' rtCircuitCurrenblx(A) - 7.24 .� Nominal operating cell temperature NOCT (800 W/mr, AM I.S. windspeed I m/s, ambient temperature 68OF (20'C). CERTIFICATION ' c �L us 10 year product warranty. 25 year linear power output warranty LIM (max, depression in performance of 0.7%p.a.). UL 1703, Fire rating: Type I. Class C p EFFICIENCY �Q YEAR PRODUCT WARRANTY YEAR LINEAR POWER OUTPUT WARRANTY O�TY»PREF US IMPORT DUTY FREE TEMPERATURE RATINGS Nominal Operating Cell Temperature(NOCT) 45.7aC(:2aC) Temperature Coefficient of P., -0.40%/°C Temperature Coefficient ofV. -0.27%/'C Temperature Coefficient of 1. 0.024 %/'C GENERALOATA Cell Type: 60 REC PE multi -crystalline 3 strings of 20 cells with bypass diodes Glass: 0.125 in solar glass with anti -reflection surface treatment Back Sheet: Double layer highly resistant polyester Frame: Anodized aluminum (black) Zep Groove compatible Junction Box: IP67 rated 0.156 in (12 AWG) solar cable, 2 x 47.24 in Connectors: H4 Amphenol Origin: Made in Singapore MAXIMUMRATINGS Operational Temperature: -40...+185°F(-40...+85'C) Maximum System Voltage: 1000 V UL Design Load: 50lbs/ft' (2400 Pa) long side 30lbs/ft2 (1436 Pa) short side Max Series Fuse Rating: 15A Max Reverse Curren: 15A REC is a leading global provider of solar energy solutions. With more than 15 years'of experience, we offer sustainable, high performing ^ products, services and investments for the solar industry. Together with our partners, we create value R by providing solutions that better f EC meet the woRd's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange(ticker:RECSOL).Our 1,600. employees worldwide generated revenues of USD 647 million in 2013. www.recgroup.com w A • wti � 1 • wti � 1 5 i . '• r t , / Perfect Welding/ Solar Energy / Perfect Charging,, Yes I DC rcveree pol�dty ptvtection ' "Yes -"�.. SHIFTING THE LIMITS A' 4 _� _ r �r FRONIUS PRIMO c _ 4 / The future of residential solar is here - Introducing the nep Fronius Primo. t i X PC boaid At- /StuplNrener /Wi-Fi®' /SbperE /Smart Grid /ArrcFavlECir. w., - ca - t\4- -W -M -a �. replxement process o ting system mter[ace Design Ready I- temiptitn � �'L / With power categories ranging from 3.8 kW to 8.2 kW, the transfoimerless Fronius Primo is the ideal compact single-phase inverter for residential applications. The sleek design is equipped with the SnaplNverter hinge mounting system which allows for lightweight, secure and convenient installation and service. ' / The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint y ` trackers, high system voltage, a wide input voltage range and unrestricted use indoors and outdoors. Other standard features include a Wi-Fi* and SunSpec Modbus interface for seamless monitoring and datalogging, Arc Fault Circuit _ Interruption (AFCI), and Fronius's superb online and mobile platform Fronius Solar.web. The Fronius Primo is - designed to adjust to future standards, offering a complete solution to code restrictions and technical innovations of tomorrow. It also works seamlessly with the Fronius Rapid Shutdown Box for a reliable NEC 2014 solution .�., a i .� TECHNICAL DATA FRONIUS PRIMO GENERAL DATA - STANDARD WITH ALL PRIMO MODELS Dimensions (width x height x depth) ! 16.9 x 24.7 s 8.1 in. I"Wetaht "I 47.2916. + 1 Degrec of protection NEMA 4X I Nigln time consum�.,ion _ < 1 W - 1 Inverter topology I Transformed- I Conlin Variables fan , hutallation i Indoor and outdoor installation Ambient o t„emne1.1me ran e _ _ _ _ _ _ _ _ - _ _ X10 •. 131'F 440... +55'Cl _ _ _ _ _ -Ong i Permitled humidity 1 0.100% I =1 D , connection terminals 4x DC+and 4x DG screw terminals far cop_pe Js lid/ stra tdrd / h.ne stranded) m aluminum lsnlid /stranded - `�.. ACconnect o f pals I S -w tormirads 12.6 AWG ('snifinies and coat} Nance with stnndmds UL ll41 2010, UL1998{fo fumlioru: Al Cl and Miat o mmtonng), IEEE 1547.2005 IEEE 1547.1.2003, ANSI/IEEE C62.41, FCC Part 15.A & 8. NF.0 Article 690, C22 2 No. 107,1.01 (§Vtember 2001) , U L16998Issi e 2 2013, CSA TII. M.07 Issue 1 -2013 PROTECTIVE DEVICES STANDARD WITH ALL PRIMO MODELS I AFCI & 2014 NEC Ready � Yes ,,) Ground Fauh Protection with Isolation Monitor - Imerru ter - Yes J I 1 . '• . DC disconnect ( Yes I DC rcveree pol�dty ptvtection ' "Yes . '• TECHNICAL DATA FRONIUS PRIMO ' OUTPUT DATA 71 PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0.1 PRIMO 7.6-1 PRIMO 8.2-/' Max. output power 208' 3800 W I SOOO W 6000 W }. 7600 W 1 '� . 7900 W M 24dIr ! 3800 IV W 5000 11 W 6000 W 7600 It W 8200 W Max. cominuous output current 208 18.3 A I 24.0 A I 28.8 A i 36.5 A 38.0 A 240 15.8 A 20.8 A 25.0 A _3_71 7 A 343 A Recommended OCPD/AC breaker size 208' 25A ( 30 A ( 40 A � 50 A, SOA 240�y 20A 30A 35A 40A 45A Max. Efficiency - 1 96.7% I 96.9% ( 96.9% t 96.9 % �. 97.0% N CEC Eflicienc 240 •. 95.0% 95.5% 96.0% 96.0 %. 96.5 % Admissible conductor sire AC I AWG 14 - AWG 6 Gdd connxtion ( ZOB / 240 Frequency • I •60 Hz Total harmonic distortion <5.0% Power fadm (cos P_ ' Sinning with serial number 26170760; before serial number: 150 V t.., ?he term Wi-Fi® is o registered trademark of the Wi-Fi Alliance r - . t , moi, • • .,. /Perfect Welding /Solar Energy /_Perfect Charging WE HAVE THREE DIVISIONS AND ONE'PASSION: SHIFTING THE LIMITS OF OSSIBILITY. - • /Whether welding technology, photovoltaics or battery charging technology -our goal is clearly defined: to be the innovation leader. With around 3,000 employees worldwide, we shift the limits of what's possible •our record of over 1,000 granted patents is testimony to this. While others progress ' step by step, we innovate in leaps and bounds. lust as we've always done. The responsible use of our resources forms the basis of our corporate policy: Further information about all Fronius products and our global sales partners and representatives can be found at www.[ronius.com ''•" - • Fronius USA LLC - • 6797 Fronius Drive` � a • �" Portage, IN 46368 ,USA lev. 5.20.15 USA N A' �r t TECHNICAL DATA FRONIUS PRIMO ' OUTPUT DATA 71 PRIMO 3.8-1 PRIMO 5.0-1 PRIMO 6.0.1 PRIMO 7.6-1 PRIMO 8.2-/' Max. output power 208' 3800 W I SOOO W 6000 W }. 7600 W 1 '� . 7900 W M 24dIr ! 3800 IV W 5000 11 W 6000 W 7600 It W 8200 W Max. cominuous output current 208 18.3 A I 24.0 A I 28.8 A i 36.5 A 38.0 A 240 15.8 A 20.8 A 25.0 A _3_71 7 A 343 A Recommended OCPD/AC breaker size 208' 25A ( 30 A ( 40 A � 50 A, SOA 240�y 20A 30A 35A 40A 45A Max. Efficiency - 1 96.7% I 96.9% ( 96.9% t 96.9 % �. 97.0% N CEC Eflicienc 240 •. 95.0% 95.5% 96.0% 96.0 %. 96.5 % Admissible conductor sire AC I AWG 14 - AWG 6 Gdd connxtion ( ZOB / 240 Frequency • I •60 Hz Total harmonic distortion <5.0% Power fadm (cos P_ ' Sinning with serial number 26170760; before serial number: 150 V t.., ?he term Wi-Fi® is o registered trademark of the Wi-Fi Alliance r - . t , moi, • • .,. /Perfect Welding /Solar Energy /_Perfect Charging WE HAVE THREE DIVISIONS AND ONE'PASSION: SHIFTING THE LIMITS OF OSSIBILITY. - • /Whether welding technology, photovoltaics or battery charging technology -our goal is clearly defined: to be the innovation leader. With around 3,000 employees worldwide, we shift the limits of what's possible •our record of over 1,000 granted patents is testimony to this. While others progress ' step by step, we innovate in leaps and bounds. lust as we've always done. The responsible use of our resources forms the basis of our corporate policy: Further information about all Fronius products and our global sales partners and representatives can be found at www.[ronius.com ''•" - • Fronius USA LLC - • 6797 Fronius Drive` � a • �" Portage, IN 46368 ,USA lev. 5.20.15 USA N ,,) 0.85-1 indJcap I % ' • ' pv-support-usa(a3fronius.ctim r " • a www.fronilis-usa.com s .- .r 1` �CSR.. r Group .Certificate" of -Co'mpHance - Certificate: 2779302 ; ; Master Contract: 203213 Project: 70027816 jr' `' w Date Issued: April 16, 20.15 Issued to: Fronius International GmbH . t Guenter Fronius Strasse 1 Weis-Thalheim, 4600 , Austria .: The products listed below are eligible to bear the CSA -. Mark shown :with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for r _ US only or_without either indicator for Canada only..; a Rolr }f evn.Pbtock,, ' Issued by: Rob Hempstock, AScT. c us PRODUCTS CLASS 531109 - POWER SUPPLIES - Distributed Generation Power Systems Equipment CLASS 531189 - POWER -SUPPLIES - Distributed Generation - Power Systems Equipment - Certified to U.S. Standards Transformerless Utility Interactive Inverter, Models Fronius Primo 3.8-1 208-240, Fronius Primo 5.0-1 208-240, Fronius Primo 6.0-1 208-240, Fronius Primo 7.6-1 208-240 and Fronius Primo 8.2-1208-240, permanently connected. For details related to ratings, etc., reference should be made to the CSA Certification Record, Annex A, and/or - the Descriptive Report. Notes: 1. All models meet the surge requirements of IEEE C62.41.2-2002, Location Category B (6kV). Tests were performed using ring wave and combination waveforms, both polarities, for common mode and differential mode coupling, 20 pulses each test. After surge testing the units were operational with control functionally verified by frequency and voltage disconnect tests. 2. The above models are intended to be used in an ungrounded power system in conjunction with the requirements specified in the National Electrical Code, ANSI/NFPA 70, 2014 Ed, section 690.35. DQD 507 Rev. 2012-05-22 Page: 1 •• 't#- CSR ayt . r •} P-. ', Group Certificate: 2779302 t 7 Master Contract: 203213 Project: t ' 70027816 "".° • _ Date Issued: April 16"2015 3. The above models are permanently connected utility -interactive inverters intended for operation with'..4 - Photovoltaic supplies only. 4. The above models are provided with integral PV DC ARC -Fault Circuit Protection for series arcing faults (hype 1)• , -APPLICAALE REQUIREMENTS r~` '�- CSA-C22.2 No.107.1 101 - General Use Power Supplies *UL Std No. 1741- 2nd Edition - Inverters, Converters, Controllers and Interconnection System Equipment For Use With Distributed Energy Sources (Rev. January 7, 2015) ' UL CRD Non -Isolated EPS Interactive PV Inverters Rated Less Than.30kVA '-UL 1699B = Outline of Investigation for Photovoltaic (PV) DC Arc -Fault Circuit Protection (Issue Number 2, January 14, 2013) CSA TIL M-07 - Interim Certification Requirements for Photovoltaic (PV) DC Arc -Fault Protection (Issue Number 1, March 11, 2013) *Note: Conformity to UL 1741 -Second Edition (Rev. January 7; 2015) includes compliance with applicable - requirements of IEEE 1547 and IEEE 1547.1 ` h - -V 1 DQD 507 Rev. 2012-05-22 y « Page: 2 t a a .- .r 1` �CSR.. r Group .Certificate" of -Co'mpHance - Certificate: 2779302 ; ; Master Contract: 203213 Project: 70027816 jr' `' w Date Issued: April 16, 20.15 Issued to: Fronius International GmbH . t Guenter Fronius Strasse 1 Weis-Thalheim, 4600 , Austria .: The products listed below are eligible to bear the CSA -. Mark shown :with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for r _ US only or_without either indicator for Canada only..; a Rolr }f evn.Pbtock,, ' Issued by: Rob Hempstock, AScT. c us PRODUCTS CLASS 531109 - POWER SUPPLIES - Distributed Generation Power Systems Equipment CLASS 531189 - POWER -SUPPLIES - Distributed Generation - Power Systems Equipment - Certified to U.S. Standards Transformerless Utility Interactive Inverter, Models Fronius Primo 3.8-1 208-240, Fronius Primo 5.0-1 208-240, Fronius Primo 6.0-1 208-240, Fronius Primo 7.6-1 208-240 and Fronius Primo 8.2-1208-240, permanently connected. For details related to ratings, etc., reference should be made to the CSA Certification Record, Annex A, and/or - the Descriptive Report. Notes: 1. All models meet the surge requirements of IEEE C62.41.2-2002, Location Category B (6kV). Tests were performed using ring wave and combination waveforms, both polarities, for common mode and differential mode coupling, 20 pulses each test. After surge testing the units were operational with control functionally verified by frequency and voltage disconnect tests. 2. The above models are intended to be used in an ungrounded power system in conjunction with the requirements specified in the National Electrical Code, ANSI/NFPA 70, 2014 Ed, section 690.35. DQD 507 Rev. 2012-05-22 Page: 1 •• 't#- CSR ayt . r •} P-. ', Group Certificate: 2779302 t 7 Master Contract: 203213 Project: t ' 70027816 "".° • _ Date Issued: April 16"2015 3. The above models are permanently connected utility -interactive inverters intended for operation with'..4 - Photovoltaic supplies only. 4. The above models are provided with integral PV DC ARC -Fault Circuit Protection for series arcing faults (hype 1)• , -APPLICAALE REQUIREMENTS r~` '�- CSA-C22.2 No.107.1 101 - General Use Power Supplies *UL Std No. 1741- 2nd Edition - Inverters, Converters, Controllers and Interconnection System Equipment For Use With Distributed Energy Sources (Rev. January 7, 2015) ' UL CRD Non -Isolated EPS Interactive PV Inverters Rated Less Than.30kVA '-UL 1699B = Outline of Investigation for Photovoltaic (PV) DC Arc -Fault Circuit Protection (Issue Number 2, January 14, 2013) CSA TIL M-07 - Interim Certification Requirements for Photovoltaic (PV) DC Arc -Fault Protection (Issue Number 1, March 11, 2013) *Note: Conformity to UL 1741 -Second Edition (Rev. January 7; 2015) includes compliance with applicable - requirements of IEEE 1547 and IEEE 1547.1 ` h - -V 1 DQD 507 Rev. 2012-05-22 y « Page: 2 t Y ®p s sv = SolarCity ®pSolar l : R 9 9Y ^SoiarGt Ze Solar Next -Level PV Mounting Technology Next -Level PV Mountln 'Technolo y • i Components _ ' ' . f • . • + f j .ZS Comp for composition shingle roofs. _ �O14PAT/, k Description PV mounting solution for composition shingle roofs ire0 Works with all Zep Compatible Modules _ ` y,, C°MP 11 - Auto bonding UL -listed hardware creates structural and electrical bond '' , - ' • - - •, ' Flashing Puck Interlock' Leveling Foot �L LISTED, , Specifications, Part No. 850-1604 a'Part No. 850-1388 Part No. 850-1603 • r ti • Listed to UL 2703 and UL 2582 Listed to UL 2703 " Listed to UL 2703 Designed for pitched roofs •.* Installs in portrait and landscape orientations ZS Comp supports module wind uplift and snow load pressures to 50 psf per UL 1703 _ L x• Wind tunnel report to ASCE 7-05 and 7-10 standards- • ZS Comp bonding and grounding products are UL listed to UL 2703 and UL 467 ; >' • Engineered for spans up to 72" and cantilevers up to 24" - • Zep wire management products listed to UL 1565 for wire positioning devices . • ZS Comp has a UL 1703 Class "A" system level fire rating when installed with modules from any manufacturer with a Type 1 or Type 2 fire classification i • _ • Attachment method UL listed to UL 2582 for Wind Driven Rain „ - Ground Zep V2 Array Skirt, Grip, End Caps DC Wire Clip Part Nos. 500-0113, 850-1421, - Part No. 8501511I. k•` Part No. 850-1448 •a 850-1460, 850-1467 ' - zepsolar.com •� zepsolaccom Listed to UL 467 and UL 2703 'Listed to UL 1565 - Listed to UL 2703 This document does not create any express warranty by Zep solar or about its products or services. Zap Solar's sole warranty is contained in the written product warranty for _ This document does not create any express warranty by Zep Solar or about its products or services. Zep Solar's sole warranty is contained in the written product warranty for each product The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely each product. The end-user documentation shipped with Zep Solar's products constitutes the sole specifications referred to in the product warranty. The customer is solely • x - • responsible for verifying the suitability of ZepSolar's products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. responsible for verifying the suitability of ZepSolars products for each use. Specifications are subject to change without notice. Patents and Apps: zspats.com. • , Document # 800-1839-002 Rev C t Date last exported: December 10, 2015 12:48 PM Document # 800-1839-002 Rev C - - `` Date last exported: December 10, 201512:48 PM • , 44 91 - h � � � . ' • ice," ' � `* O. . Y•iw ' •