HomeMy WebLinkAboutB16-0715 000-000-000` -APPROVAL STAMP AND ADDITIONAL -NOTES FOR THE CITY OF: CHICO r•'
SHEET'INDEX , =
SYSTEM OVERVIEW
PROJECT NOTES: w _ ' '. COVER `'
(N) 15KW PV SYSTEM INSTALLED
PLOT .PLAN: � � . ` _ - ' PV -I ,, ' '•
'
�Y
. .. • ..
RESIDENTIAL MAIN SERVICE PANEL: 5.4KW
PHOTOVOLTAIC LAYOUT: • • -
ATTACHMENT LAYOUT &CALCULATIONS: PV -2 'tw
' ', (18)`LG LG300NIK-G4
_ r •,, -' . y' s ,, , , 2•
ATTACHMENT. DETAILS_ . .. PV -2.1
,�
..
,..
ELEVATION DETAILS: • PV -2.2 T
(18)'ENPHASE M250-60-2LL-S22
,'
FIRE SIGNS/LABELS: r PV -3 .. ^ `
,�,1 . t=:
(COMMERCIAL'MAIN SERVICE PANEL: 9.6KW
_
L
SINGLE LINE DIAGRAM: _ PV -4 _
t , ' ".' -
(32):LG300NIK-G4
LG
'
SEPARATE PLACARD: ATTACHED '
•:,'.
.:.
MANUFACTURE SPEC. SHEETS: ATTACHED
(32) ENPHASE-M250-60-2LL-S22_
-
GENERAL NOTES
r,`,:CUSTOMER INFORMATION
• ALL WORK TO COMPLY WITH (2011 NEC) 2013 CALIFORNIA ELECTRIC-CODE1,
", '. ` ` ,ANTHONY. GENTILE
L' _
ARTICLE 690,, 2013 CALIFORNIA BUILDING CODE. '"
r
' ' µ 2270 NORTH ,LINDO AVENUE
`: f . - -
• CONDUCTORS EXPOSED TO,SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT
. _
�
PER.NEC 310.0(D)
',' +: A CHICO, CA 95973 r'
,. .
• CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE:IN;WET
'
LOCATIONS PER NEC 310.8(C) '
€ ' r* . (56 2) 277-4016
•
• WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT,`
;APN #047-080-074
WILL BE MAINTAINED IN ACCORDANCE WITH THE NEC 110.26'
CONTRACTOR INFORMATION
-
• EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. y '.
`
• SMOKE ALARMS AND CO2 ALARMS TO BE INSTALLED
_
' i " s
• -STRUCTURAL MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED s
` 'SOLAR SOURCE INC.
AND VERIFIED AS NECESSARY FOR LAG BOLT PENETRATIONS BY CONTRACTOR.
W 's ' '
• SEAL,CONNECTION POINTS WITH ROOF.GRADE F=}4;•.
,, s,` 4801- E,, ANAHEIM STREET
r' '� f ! . -
• - ROOF PENETRATIONS ARE SEALED WITH SCHNEE MOREHEAD 7108. SEALANT. -
t LONG` BEACH, CA 90804 `
` ` "•
• PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY,WIRING
_
ti ..
•'
TO CONDUIT WIRING. -.-: '..
r ' (562) 852-5626
' t ` `' r '�
• PV_POWER SOURCE, 600VDC, 240VAC, VISIBLE, LOCKABLE, NEMA 3R RAINPROOF,
i"
30A AC DISCONNECT.
SOLAR SOURCE INC.
_ - k
y
•` PROVIDE GROUND ELECTRODE SYSTEM -FROM INVERTER TO EXISTING MAIN::.6
'`
#925231
. ,
SERVICE GROUND ELECTRODE. - -
-
•
- ,` '- . •
• GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE TO BE
^y-6
- • -
MINIMUM PROTECTION OF BARE ARMOR SHEATED CABLE FOR ALL CONDUCTOR
y
SIZES.
`
• ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL.
X
' '
• INVERTER IS LISTED TO UL -1741 "UTILITY INTERACTIVE"
s r r;
• ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. ..
•
• ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2.
r r
• MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%
,
BUTTE' `' Y
• ALL CONDUCTORS SHALL BE IN CONDUIT'UNLESS OTHERWISE NOTED.
APR 1 1 201 x .5 '
.
'
VICINITY MAP
SOLAR -sous
•- D:EVELOPMEN•h • - �
"
�RESIDEWIAC:L COMMERCIAL SOLAR PROFESSIONALS
SERVICES
�
07/�
•Q/6
REV. DESCRIPTION DATE
_
T•
2270 N Lindo Ave :--.�--.•..---
A 'INITIAL DRAFT 3/17/2016
r•
- 1 I
C 'hv `•
I
D
•
• (E) OCCUPANCY GROUP: R -3F
� { f
1'
DATE: 4/8/16
SYSTEM OVERVIEW
'
• (E) TYPE OF CONSTRUCTION. V—B -' ,
• (E) SPRINKLERS: NO
,�r*
COVER
DRAFTER: NM
t
SYSTEM OVERVIEW
634'-11"(N) 15KW PV SYSTEM INSTALLED
RESIDENTIAL MAIN SERVICE PANEL: 5.4KW
(18) LG LG300NIK-G4
(18) ENPHASE M250-60-2LL-S22
COMMERCIAL MAIN SERVICE PANEL: 9.6KW
(32) LG LG300NIK-G4
(32) ENPHASE M250-60-2LL-S22
o• CUSTOMER INFORMATION
°O s ANTHONY GENTILE
I 2270 NORTH LINDO AVENUE
�O CHICO, CA 95973
. F (562) 277-4016
APN #047-080-074
CONTRACTOR INFORMATION
0"
SOLAR SOURCE INC.
\eI�aae,4801 E ANAHEIM STREET
281'-5
LONG BEACH, CA 90804
230'-5" (562) 852-5626
Driveways SOLAR SOURCE INC.
b [North Lindo Avenue] 46 #925231
lb
DET I A_PVI. —I -
X
c,
Ln
0� ���
N soLn •SOURC
RESIMMIAL ✓ COMMERCIAL SOLAR PROFESSIONALS
PLOT PLAN & INSTALL LOCATION
SCALE:. ["=1.50'
PV (50) LG LG300NIK-G4 SP 125A "PV DEDICATED" SUB PANEL E:] PV SOLAR MODULES -FLUSH MOUNTED REV. DESCRIPTION DATE
OP INV -1 ® ® VENTS & OBSTRUCTIONS ® CHIMNEY A" INITIAL DRAFT 3/17/2016
MICRO (50) ENPHASE M250-60-2LL-S22 INV -2 ROOF ACCESS POINT: ROOF ACCESS POINT SHALL BE- LOCATED B
,
MSP INV -3 IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS C
OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG D
MSP -D - JB JUNCTION BOX POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE' -ACCESS E
MSP -U PROPOSED PV CONDUIT RUN ABOVE ROOF POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS
TREE LIMBS, WIRES OR SIGNS. DATE: 4/8/16 PLOT PLAN
PM i'- PROPOSED PV CONDUIT RUN THROUGH ATTIC
AC PROPERTY LINES DRAFTER: NM P V — I
INSTALL LOCATION
SCALE: 1" = 30'
PV
OP
I
1-1/4" Schedule 40 Through 1
Trench, Buried min: 18" Below 1
Grade, Approx. 80' Length 1
1 AC
1
100A Meter w/Bypass
Blocks, 3-phase, 240V
(50) LG LG300NIK-G4
MICRO (50) ENPHASE M250-60-2LL-S22
MSP
MSP -D
MSP -U
PM
AC 60A FUSED AC DISCONNECT W/60A FUSES
SP 125A "PV DEDICATED" SUB PANEL
INV -1
INV -2
INV -3
JB JUNCTION BOX
PROPOSED PV CONDUIT RUN ABOVE ROOF
i PROPOSED PV CONDUIT RUN THROUGH ATTIC
-� PROPERTY LINES
TEM
SYSTEM OVERVIEW
(N) 15KW PV SYSTEM INSTALLED
RESIDENTIAL MAIN SERVICE PANEL: 5.4KW
(18) LG LG300NIK-G4
(18) ENPHASE M250-60-2LL-S22
COMMERCIAL MAIN SERVICE PANEL: 9.6KW
;(32) LG LG300NIK-G4
(32) ENPHASE M250-60-2LL-S22
CUSTOMER INFORMATION
ANTHONY GENTILE
2270 NORTH LINDO AVENUE
CHICO, CA 95973
(562) 277-4016
APN #047-080-074
CONTRACTOR INFORMATION
SOLAR SOURCE INC.
4801 E ANAHEIM STREET
LONG BEACH, CA 90804
(562) 852-5626
SOLAR SOURCE INC.
C46 #925231
X
SOLAR SOURCE
RESIDENTIAL / COMMERCIAL SOLAR PROFESSIONALS
0 PV SOLAR MODULES - FLUSH MOUNTED REV. DESCRIPTION DATE
® ® VENTS & OBSTRUCTIONS ® CHIMNEY A INITIAL DRAFT 3/17/2016
ROOF ACCESS POINT: ROOF ACCESS POINT SHALL BE LOCATED B
IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS C
OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG D
POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS E
POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS
TREE LIMBS, WIRES OR SIGNS. DATE: 4/8/16 INSTALL LOCATION
Pv—DRAFTER: NM I . I
' F w
PV MODULES FIRE CLEARANCE AREA ® ® OBSTRUCTIONS is ROOF PENETRATION POINTS + fi -- RAFTERS --- RAILS PROPERTY LINES ,^:' SYSTEM OVERVIEW
!., �(N) 15KW P.V SYSTEM INSTALLED
• E !' RESIDENTIAL'MAIN SERVICE PANEL: 5.4KW.
(18) LG LG300NIK-G4
` { �' ti - _ +.,• �< ''_ . +` '?.i' . .rte (18) ENPHASE,M250-60-2LL-S22
- . r .r "• ,.� 4 `COMMERCIAL MAIN,SERVICE-PANEL: 9.6KW
'(32) LG LG300NIK-G4
(32)`ENPHASE M250-60-2LL-S22
d. f. r.
- s�. • _' f �:.: .• �. CUSTOMER, INFORMATION
r + e
ANTHONY GENTILE ..
i j } 2270 (NORTH UNDO AVENUE
_ � .- - , � _ PFS _ ' � , ..� • ' , s �• �; � , *^�'< ,� r,, '� .��. - K • ,:
F . ' 1p CHICO,,CA 95973
(562)-277-4016
�' (� 3�`�,, c�Q +• �' APN #047-080-074
,CONTRACTOR INFORMATION
— S - 4�{ .!: ` f '• /' , P` .- ' R1 SOLAR SOURCE INC. -
" f - - ♦ . , +�Vr. - �/ - i .., - . - !. �- a ^w, :� 4801.k.E-'ANAHEIM STREET
'LONG BEACH; CA 90804,
�; ' (562), 852-5626
4': SOLAR SOURCE _INC.'.,
a� , _ 3 :r:: Y♦. = , r . F : �:, C46 #925231
A.
\/�'�?cel 1 - � •y � *f _ ., .n _ "� ; • ^, r .
SOLAR SOURCE'
=N R2 RESIDENTIAL / COMMERCIAL.SOLA; ?ROFESSLON/�LS
R3
ATTACHMENT DETAIL i TAG ROOF INFORMATION „` REV. DESCRIPTION' DATE
„._ ,' „ * �" RI 24 MODULES,.COMP: SHINGLE ROOF, 145° AZIMUTH�;IS° TILT,, MOUNTED BILL OF MATERIALS rj�. A INITIAL DRAFT 3/17/2016
SCALE: 1/16 - I —0 . �. ;.� •
R2 20 MODULES, COMP. SHINGLE ROOF, 120° AZIMUTH,`15° TILT, FLUSH MOUNTED. N0. PRODUCT DESCIPTION QTY. -
B
MOUNTING INFORMATION R3 6 MODULES, COMP.'SHINGLE ROOF, 2120 AZIMUTH;',IS°-TILT„FLUSH MOUNTED' :' I LG LG300NIK-G4 ♦ 50 C
MOUNTING SYSTEM MANUFACTURER: EVEREST 164 RAILS WITH QUICK MOUNT Q -RACK „ PV EQUIPMENT INFORMATION_ ? 2 ENPHASE M250-60-2LL-S22 50 D
TOTAL WEIGHT OF MODULES & RACKING (LBS): 2052 { MODULE WEIGHT: 37.48 LBS 3 EVEREST 164” RAILS 25 E "
NUMBER OF ATTACHMENT POINTS: 74 -,. MODULES SQ.FT..(64.57" x 39.37" X 1.57") 17.65 4- QUICK MOUNT Q -RACK 74
a ATTACHMENT LAYOUT ,
WEIGHT (LBS) /ATTACHMENT POINT 27.73 �' • ARRAY SQ.FT. `= .882.68 5 EVEREST END CLAMPS " ,` '32 DATE: 4/8/16
TOTAL SURFACE AREA OF PV•MODULES (SQ.FT.): 882.68'x'• RACKING WEIGHT:', `y . .3.63.56 LBS/MODULES 6 EVEREST MID CLAMPS 80 PV -2
DISTRIBUTED WEIGHT OF PV MODULE.ON ROOF (LBS/SQ.FT.): 2 32 ROOF LOAD (MODULE WEIGHT / MODULE AREA): 2.12 LBS/SQ.FT. - DRAFTER' NM
CONDUIT DETAILS
ATTACHMENT DETAILS
SYSTEM OVERVIEW
(N) 15KW PV SYSTEM INSTALLED
T -BOLT
END CLAMP
RESIDENTIAL MAIN SERVICE PANEL: 5.4KW
(18) LG LG300NIK-G4
RAIN TIGHT, STEEL EMT CONNECTOR.
STRUT STRAP
EVEREST SUPPORT RAIL
(18) ENPHASE M250-60-2LL-S22
_ BELL BOX
PV MODULE MIN. 3.5" ABOVE ROOF
COMMERCIAL MAIN SERVICE PANEL: 9.6KW
STRAIN RELIEF
(32) LG LG300NIK-G4
DC (PV) OR AC (MICROINVERTER)
(32) ENPHASE M250-60-2LL-S22
CABLE
L -Fool
CUSTOMER INFORMATION
MODULE
6" STANDOFF
/
ANTHONY GENTILE
_-
COMP. SHINGLE ROOF
�j�j
2270 NORTH LINDO AVENUE
/
- CHICO, CA 95973
O.C. i
/
(562) 277-4016
RAFTER
„Rafter /
� 2" X 6
APN #047-080-074
CONTRACTOR INFORMATION
2" X 6" BLOCK
//
EMT CONDUIT ABOVE ROOF MAX HEIGHT: 3,V"
SOLAR SOURCE INC.
MIN HEIGHT: %"
4801 E ANAHEIM STREET
(2) 5/16"X3" LAG BOLT (MIN. 2.5" EMBEDDED)
LONG BEACH, CA 90804
(562) 852-5626
SOLAR SOURCE INC.
GROUNDING DETAIL
- C46 25231
MODULE TO MODULE
MODULE TO RAILS
RAILS TO RAILS
X
SELF TAPING SCREW
SOLAR SOURCE.
PV MODULE
RESIDENTIAL / COMMERCIAL SOLAR PROFESSIONALS
USE WEEBL-6.7 ASSEMBLY PER
MID -CLAMP
RAIL TO CONNECT SYSTEM TO
EQUIPMENT GROUND CONDUCTOR.
REV. DESCRIPTION DATE
WEEB-PMC
GROUND BONDING JUMPER
RACKING
A INITIAL DRAFT 3/17/2016
SLIDING NUT
B
NTS REMOVAL OF ONE PIECE OF EQUIPMENT SHALL
C
NOT DISCONNECT THE NDING
D
MOUNTING RAIL
BETWEEN ANY OTOHER PIE CE
BETWEEN
E
DATE: 4/8/16
ATTACHMENT DETAILS
PV -2.1
DRAFTER:: NM
PARTIAL FRAMING DETAIL
MODULE HEIGHT
DETAIL
SYSTEM OVERVIEW
(N)•15KW PV SYSTEM INSTALLED
RESIDENTIAL MAIN SERVICE PANEL: 5.4KW
(18) LG LG300NIK-G4
(18) ENPHASE M250-60-2LL-S22
COMMERCIAL MAIN SERVICE PANEL: 9.6KW
Beam, Truss Bracing, or Bearing Wall
- (32) LG LG300NIK-G4
(32) ENPHASE M250-60-2LL-S22
CUSTOMER INFORMATION
ANTHONY GENTILE
CV
2270 NORTH UNDO AVENUE
LU w
CHICO, CA 95973
0 0
(562) 277-4016
O
APN #047-080-074
LU o
C3
CONTRACTOR INFORMATION
w
Q
SOLAR SOURCE INC.
4801E ANAHEIM STREET
LONG BEACH, CA 90804
(562) 852-5626
�-2° X 6° RAFTERS, 24° 0. C., MAX SPAN: 6----;."`
:SOLAR SOURCE INC.
C46#925231
X
ELEVATION VIEW
COMMERCIAL ELEVATION VIEW =
RESIDENTIAL
TO PV
ARRAY WITH
MICROINVERTERTO
M
PV
ARRAY WITH
MICROINVERTER
SOLAR SOURCE,
RESIDENTIAL / COMMERCIAL SOLAR PROFESSIONALS
M .
O
REV. DESCRIPTION DATE
A C
S P
S P S
A INITIAL DRAFT 3/17/2016
B
P
TO PV ARRAY
TO PV ARRAY
C
THROUGH TRENCH
GRADE
GRADE
THROUGH TRENCH
D
E
18' MIN.
L----------J
DATE: 4/8/16
ELEVATION DETAILS
GRADE
Pv-2.2-j
DRAFTER: NM
{
SYSTEM OVERVIEW
(N) 15KW PV SYSTEM INSTALLED
RESIDENTIAL MAIN SERVICE PANEL: 5.4KW
(18) LG LG300NIK-G4
(18) ENPHASE M250-60-2LL-S22
COMMERCIAL MAIN SERVICE PANEL: 9.6KW
(32) LG LG300NIK-G4
. (32) ENPHASE M250-60-2LL-S22
Collector {�
M CUSTOMER INFORMATION
Panel / ANTHONY GENTILE
Solar 2270NORTHUNDO AVENUE
■ Oa A + _ CHICo, CA 95973.
J B Load /,1 - M�7P (562) 277-4016
Center C APN #047-080-074
CONTRACTOR INFORMATION
AC PV COMBINER SOLAR SOURCE INC.
PHOTOVOLTAIC AC DISCONNECT
AC DISCONNECT MAIN SERVICE PANEL MAIN SERVICE DISCONNEC 4801 E ANAHEIM STREET
04A 908
MAXIMUM Ac OPERATING CURRENT: 2$.25A PHOTOVOLTAIC AC DISCONNECT WARNING MAIN PV SYSTEM, LONG BEACH, C ,
MAXIMUM AC OPERATING VOLTAGE: 240V MAXIMUM AC OPERATING CURRENT: P8•25A ELECTRICAL SHOCK HAZARD DISCONNECT -*'
DO NOT TOUCH TERMINALS. (562) 852-5626
Per NEC 690.54 MAXIMUM AC OPERATING VOLTAGE: 240V TERMINALS ON BOTH THE LINE AND PER NEC 6 NEC6 0.15 IFC NEC690..1,
11 LOAD SIDE MAY BE ENERGIZED IFC 605 11.14, EC 690.15 &C 690.53
® WARNING ® Per NEC 690.54 IN THE OPEN POSITION CAUTION: SOLAR SOURCE INC.
ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC PER NEC 690.17(4) SOLAR ELECTRIC SYSTEM CONNECTED 046 #925231
DO NOT TOUCH TERMINALS. PER NEC 690.14(C)(2), IFC 605.11.1, ,
TERMINALS ON BOTH THE LINE AND AC DISCONNECT WARNING. IFC 605.14.1.4, NEC 690.15 & NEC 690.53
LOAD SIDE MAY BE ENERGIZED
Array (Modules and Microinverter) IN THE OPEN POSITION TURN OFF PHOTOVOLTAIC SOLAR DISCONNECT
PER NEC 690.17(4) Per NEC 690 14(0)(2) & 696.15 AC DISCONNECT PRIOR TO X
WARNING: PHOTOVOLTAIC WORKING INSIDE PANEL PER NEC 605.11.1
POWER SOURCE PER NEC 110.27(C) & OSHA 1910.145(F)(7)
PER NEC 690.31(E)(3) & IF 605.11.1.2 _
WARNING
SOLAR CIRCUITS ONLY.
- NO OTHER LOADS -
ALLOWED. ISOLA .' SOURCE
RESIDENTIAL / CONIMERCIAL SOLAR PROFESSIONALS
When It's A Microlnverter System
PV SYSTEM IS SUPPLIED WITH
MICROINVERTERS LOCATED AT ROOF
MOUNTED PANELS
REV. DESCRIPTION DATE
A INITIAL DRAFT 3/17/2016
FORMAT:
(1) WHITE LETTERING ON A RED BACKGROUND. B
(2) MINIMUM % INCHES LETTER HEIGHT. C
(3) ALL LETTERS SHALL BE CAPITALIZED
D
(4) ARIAL OR SIMILAR FONT, NON -BOLD. "
MATERIAL: E
REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE t DATE: 4/8/I6 NEC FIRE LABELS
FOR THE ENVIRONMENT (USE UL -969 AS STANDARD FOR
WEATHER RATING). DURABLE ADHESIVE MATERIALS Pv_3
DRAFTER: NM
PV MODULE INFORMATION
(32) LG LG300NIK=G4
POWER AT STC: 30OW
POWER AT.PTC: 273.4W
- V -OC (OPEN -CIRCUIT, VOLTAGE) .' 39.7V
V -MP ,(MAX -POWER. VOLTAGE).: 32.5V
I -SC (SHORT-CIRCUIT CURRENT) : 9.7A
I -MP (MAX -POWER: CURRENT) : 9.26A
MNFR V -OC TEMP'COEFFICIENT:-0.28%/°C
` (1-sC x 1.25 x 1.25) : 15.16A
N
PM
AC
AMBIENT TEMPERATUREINFORMATION
AMBIENT TEMP. 40° C
'AMBIENT TEMP. ABOVE ROOF:' 62° C
EXTREME MIN TEMP: : -4° C.
VOLTAGE DROP INFORMATION
TOTAL DC VOLTAGE DROP % :.0
.TOTAL.AC VOLTAGE DROP % :.0..4$
TOTAL SYSTEM VOLTAGE DROP % : 0:48 .
SYSTEM OVERVIEW
(N) 15KW PV SYSTEM. INSTALLED
RESIDENTIAL MAIN SERVICE PANEL: 5.4KW
(18) LG LG300NIK-G4 '
(18) ENPHASE M250=60-2LL-S22-
COMMERCIAL MAIN .SERVICE PANEL: 9.6KW
(32) LG LG300NIK-G4
(32) ENPHASE M250-60-2LL-S22
CUSTOMER- INFORMATION
: 'ANTHONY GENTILE
2270 NORTH LINDO AVENUE
CHICO, CA 059.73.
(562) 27774016:
: APN #047-080-074
AC:I.
(2) TRUNK CABLE W/INTEGRATED GROUND
(2) #6 AWG BARE COPPER GROUND
IN FREE AIR To .J -BOX:
AMPERAGE 13.2
PER NEC 310.15(B)OXA) :.l
PER NEC 310.15(B)(2)(A) 0.65
(13.2) / 0 x 0.65)-:, 20.3`
DISTANCE IN FEET ': 5:
VOLTAGE DROP % 0.12
J
QAC.3
L1 3 N
L.1
L1
L1 '
�_
.'
®_
L1
L1 .
2oA
iooA
2
N
E�G
N3::.
Lu
G
-E,G
G
-
-
/
Ground Rod
Lu
G
.
G
G
L1
L1
L1
AC:I.
(2) TRUNK CABLE W/INTEGRATED GROUND
(2) #6 AWG BARE COPPER GROUND
IN FREE AIR To .J -BOX:
AMPERAGE 13.2
PER NEC 310.15(B)OXA) :.l
PER NEC 310.15(B)(2)(A) 0.65
(13.2) / 0 x 0.65)-:, 20.3`
DISTANCE IN FEET ': 5:
VOLTAGE DROP % 0.12
20A (E) GROUNDING
\ \ .125A SUB -PANEL ELECTRODE
N W/ 100A .BREAKER
G
J=BOX
�.'
NEMA: 3R:
AC. -2,
(5).4I0'AWG. THWN-2
(1) #6 AWG THWN-2 GROUND
3/4" EMT.CONDUIT.
AMPERAGE 13.2'
PER NEC 310.15(B)(3)(A) :.0:8
PER NEC 310.15(B)(2)(A) : 0.91
(13.2) / (0.8 •x. 0.91) 18..13
DISTANCE -IN FEET : 15
VOLTAGE DROP % : 0.22
At. 3
(3).#10 AWG THWN-2
(1) #6 AWG THWN-2 GROUND'
3/4" EMT CONDUIT.
AMPERAGE 28.25'
PER NEC 310.15(B)(3)(A) ': I
PER NEC 310:15(13)(2)(A) < 0.91
.(28:25) / (1 x'0'.91) 31.04
DISTANCE IN FEET:: 5: '
VOLTAGE DROP % 0.15
J
20A (E) GROUNDING
\ \ .125A SUB -PANEL ELECTRODE
N W/ 100A .BREAKER
G
J=BOX
�.'
NEMA: 3R:
AC. -2,
(5).4I0'AWG. THWN-2
(1) #6 AWG THWN-2 GROUND
3/4" EMT.CONDUIT.
AMPERAGE 13.2'
PER NEC 310.15(B)(3)(A) :.0:8
PER NEC 310.15(B)(2)(A) : 0.91
(13.2) / (0.8 •x. 0.91) 18..13
DISTANCE -IN FEET : 15
VOLTAGE DROP % : 0.22
At. 3
(3).#10 AWG THWN-2
(1) #6 AWG THWN-2 GROUND'
3/4" EMT CONDUIT.
AMPERAGE 28.25'
PER NEC 310.15(B)(3)(A) ': I
PER NEC 310:15(13)(2)(A) < 0.91
.(28:25) / (1 x'0'.91) 31.04
DISTANCE IN FEET:: 5: '
VOLTAGE DROP % 0.15
PV MODULE INFORMATION
(32) LG LG300NIK-G4
POWER AT STC: 30OW
POWER AT PTC: 273.4W
V -OC (OPEN -CIRCUIT VOLTAGE) : 39.7V
V -MP (MAX -POWER VOLTAGE) : 32.5V
I -SC (SHORT-CIRCUIT CURRENT) : 9.7A
I -MP (MAX -POWER CURRENT) : 9.26A
MNFR V -OC TEMP COEFFICIENT: -0.28%/°C
0-sc x 1.25 x 1.25) : 15.16A
125A SUB -PANEL LUG ONLY
(N) PV BREAKER : 20A
(N) PV BREAKER : 20A
TOTAL OUT -PUT : 26.4A
(DI.-
zz
U 37
Q CL
> cs
CL U-1
cD i__
z
�w
Q37
> d
CL W
AC.I -
(2) TRUNK CABLE W/INTEGRATED GROUND
(2) #6 AWG BARE COPPER GROUND
IN FREE AIR TO J -BOX
AMPERAGE 13.2
PER NEC 310.15(8)(3)(A) : I
PER NEC 310.15(B)(2)(A) : 0.65
03.2) / (I x 0.65) : 20.3
DISTANCE IN FEET 5
VOLTAGE DROP % : 0.12
STRING INFORMATION
TAG DETAILS
A 16 MoD's, 145° a 1200 Az, 151 TILT
B 16 MODS, 120° & 2121 Az, 15° TILT
(32) ENPHASE M250-60-2LL-S22 (240V)
TAG (LOA X CITY. X 1.25): BREAKER SIZE
A (I.OA x 16 x 1.25): 20A (20A)
B 0.0A x 16 x 1.25): 20A (20A)
C
D
E
F
G
H
AC.2
AC. I _ _ . -
AC. 2
(5) #10 AWG THWN-2
(1) #6 AWG THWN-2 GROUND
3/4" EMT CONDUIT
AMPERAGE 13.2
PER NEC 310.15(B)(3)(A) : 0.8
PER NEC 310.15(B)(2)(A) : 0.91
03.2)/(0.8x0.91): 18.13
DISTANCE IN FEET 15
VOLTAGE DROP % : 0.22
AC.3
(3) #10 AWG THWN-2
(1) #6 AWG THWN-2 GROUND
3/4" EMT CONDUIT
AMPERAGE: 28.25
PER NEC 310.15(B)(3)(A) : I
PER NEC 310.15(B)(2)(A) : 0.91
(28.25) / 0 x 0.91) : 31.04
DISTANCE IN FEET 5
VOLTAGE DROP % : 0.15
PM -
AC 30A KNIFE -BLADE AC DISCONNECT
AMBIENT TEMPERATURE INFORMATION
AMBIENT TEMP. : 40° C
AMBIENT TEMP. ABOVE ROOF: 62° C
EXTREME MIN TEMP. : -4° C
VOLTAGE DROP INFORMATION'
TOTAL DC VOLTAGE DROP % : 0
TOTAL AC VOLTAGE DROP % : 0.48
TOTAL SYSTEM VOLTAGE DROP % :'0.48
To Utility Grid
Overhead
Service Drop
SYSTEM OVERVIEW
(N) 15KW PV SYSTEM INSTALLED
RESIDENTIAL MAIN SERVICE PANEL: 5.4KW
(18) LG LG300NIK-G4
(18) ENPHASE M250-60-2LL-S22
COMMERCIAL MAIN SERVICE PANEL: 9.6KW
(32) LG LG300NIK-G4
(32) ENPHASE M250-60-2LL-S22
CUSTOMER INFORMATION
ANTHONY GENTILE
2270 NORTH .UNDO AVENUE
-CHICO, CA 95973
(562) 277-4016
APN #047-080-074
CONTRACTOR INFORMATION
SOLAR SOURCE INC.
4801 E ANAHEIM STREET
LONG BEACH, CA 90804
(562) 852-5626
SOLAR SOURCE INC.
C46#925231
Ground Rod X T
(E) GROUNDING
ELECTRODE
_ SOLAR SOURCE'
RESIDENTIAL / COMMEitC1AL SOLA;t ?;t0FESSIONALS
REV. DESCRIPTION DATE
A INITIAL DRAFT 3/17/2016
B
Ci
D
E
DATE: 4/8/16 9.6KW THREE PHASE SLD
DRAFTER: NM PV-40*1.,
S
PLACARD
CAUTION
POWER TO THE BUILDING IS ALSO SUPPLIED FROM
THE FOLLOWING SOURCES WITH
DISCONNECTS LOCATED AT SHOWN
SERVICE POINT PV DISCONNECT
UTILITY METERING
- e� � • � . }_ ` 4, .. i n, nor . , - 4 .. r �'� ft - j.. .�-, • -J
- + r,- - - .- �.��' •• ] 'r d � r. }� t .y ' °��-_ � ,a" s .• - - _ r W-_., d. t• �a,� 1 .Y - .. r -' r
/ !; >1�F '• +_ � � -, d ( _ 9' •"� � � t`.- sly r, `L!• t_ ` * Y .'. (, � !�• ,,,. F .. y " •
47
-:. + to •�{ ,� r - . _,, • �. •I n ^ '3 . +. 4: � .. ,' a' a ^, t' a~ -
r Fa• , - . FF - (,, _s ,•j, r `•4. '1 a `� Fs -T .. J . • •c)', •z' ,R• fly kn Air - .
' � �L''�� _ kr,, ,.a _ s /. 7 •- ,tai ./ _. • •.. T r'• -4 \- � Ey1 ,
• r f.. ' - •.' , Irk • t .. ' d . - • 7 Y - / 4 I ^• • • �. a ' • 'w
•', - .•,.e •' . •,�+ .•. t r r'•. y •' - - •• - },r` .. � •..♦ t , ,•y s- �� - r '`.! • • •I" � A yZ.♦ A a �•
;. S LG NeON'zemcka
® LG • • • • t - • - �.. i..' $ •► 2 • EnMesD M250 Micrainverter // DATA • r_. Life, • ` .' y
A n'••i...i - Mluhental P,,opintln - .v' �• Electtiod Properties (STC •) - t Enphass, orolnvertere 1•-e r• '�. ] INPUT DATA (DC) - M260.80.2LL-S22, M260 -BD -2L4825 a
.. Better y " .•
_• ' • mw ' - • �li•Commen__ Input Powe (STC) � 2101310 W
• •i us w.m -m uw wrca.rvwv> ]zs L% _
v - Mezbn , OC voO Be ti' 48v _
�� �°�--—rm.•t�e, B�e �Enphas&M250' r Peekpowerr9ckhgveltega, 27V 39V
I54)5.156.)smm/41me Opm CYnuhtyh•W abt) l9) 4• a ' O tin Y IBV 48V -
•'wt �' •V rt` .Mw,mv lx(rAdl Wxe &rtav10 Sbttkdt tw.•nlhv) 9th 1' ., . - • • d , y ' . Operating _ _ � ♦ .
.. ebwebm (l•WN) ifia0. re0D. •0mm ap •{ MINMex alert vallage 22 V/48V • "�
�� - 6a5).39J).1.51YN ae•rrk,e T•,nrw•vtSl-a0-•90 - ♦. _ _
' nantaW sonow/tx5od0 - e�9raw vvlrr.M. taco s•� - .I � 1 - Max DC airort circuit curtanl � 15A
Mla•a - LOOWI,I)I,✓• Seln M•RnxiaW m .; } - i " . . - - .
w•ya I)Ozgs10/])aezl.Iw ltd,mx•pp o -•l • a T. yX7-N'. OUTPUT DATA IAC) 0208 VAC .0200 VAC�,a,erac.v.a •..renm.wra.. ..s_ \`r. . ` _250wz50®e)•1 391—oodr ""',"�ii4,"'`+•""`.A, .- • i. 1' ,. c Rated (continuous) output power 240W _ .. 240W
y, t•va'h>am
-000---l— - L r t * ♦ -: s NOMnaI olnpul wrreni 1.15 A U rma M nominal curelbM1.0 A (A rma at nominal c umllor0� 4 .
m - = Hp,TmvNmml,.rpemfAtn - t t - _ �
• „w„�,N„v,,,, _ ElecwolPropataea(NDrn) • „.. .> NominelwilaeeAenBe - 209v/1e322ev zdov/2n.2edv .
tbadsTv mow \+.} +ti �, - 6. �. Nominal Irequancynenge _ 80.0/57-61 Hz _ _ _ Sao 157-61 Hz
Certificatio
and
F ¢' gwuevrleNmry gCGIxIS�E[4tlm-I/] YW_,HIp.�M,gp) ) _xvJ e4.lri �' �? ;h3 Extended frequency range'- ' 57-82.5 Hz R. 57-82.5 H.
t e - gtsma(Nma8reR7 rsPu..m,roAol ' ]JB ,. V • , Power factor
LGNON'2 e(u�k tic e,]e, (,n scege d o l �am_ar • Y n a P�) ]4a i Maximum unite Par 20 A branch circuit 24 (three Phase) ; ! Ifi (single phase)
Ne , rie9001 <w.•,a ll.q ^ ]al -
_ 4 LLIra] rt...vurve., n.w•nree. e.. •......• ..r. • • , ..yy�s - k ., , Maximum output fault Conant 850 mA rtre for ecycles 850 mA rm9for8ryel
' rend. ra.wa•.x. tusA) r,vxea,m» - 1 r - 1 to i j) - a� ::..t • • EFFICIENCY
e 7"r' �. �.'�- ra.wnA,h(N.uNAw) cwctuc/amn)w) •.Dimensions (mnfin)•' { .' .� i''' it 1 '�,) 1, .-. cEcweigmedefnaene>• ses% _ _ i .
r ,
.. Ulls ne v modu4. ly WON- 2 911 adopts Cd. 1 - Prm,n w.n•n' I xwa, O - • _ ` � 4j[:. , � -. Peak lmarder e8klanuy * 96.5% _
tedv%WM Cello tedtmlopy radazas 3bushvs with Mv,a,vasv,ov' ..y �ug u•..�rurtar,�.0 - - F'a a • 1.
•^iO`�'�t •n,.,� w • , ��'rrr---}������ i^, Sleue MPPr flkleney (weighted, reference EN50530) 89.4%y -
uity
USNe memrrcepolNtandmtoinc v / ® '_ ~ r • _ ax _
60 tie ll LL NeON• 2 Black demonstrates Gl elfvms m In ma e D E C E ®' Tempe aturo Characteristics ectedstlo _ f{��1 1 Nigh time AN CAL —.ptin 65 mW max
customees values beyaM efficiency. It featums enhanrn0 `, ` hoer e4z]< 3-1— 13 •• - 'MECHANICAL DATA -
nucxdu,ability, performance under mal emdronment, '°��•"'�gNp -0JB 411 a..,, • • ' -
andaesthetkdeslgnsuitable for roafz . e4. n, amlyc `� '^` •A ••i • �blem temperelureronge -d0°C to •85•C
• - r r • - - -
a.— - - - r' �I .. -_-- - ^. The Enphase• M250 Microinverter delivers Increased energy harvest and reduces design and - Dimensions (wxHxD) - _ - 171 mm x 173 mm x 30 mm twithum mounting breckeQ
- Characteristic curves ':. installation complexity with its all -AC approach. With the M250, the DC circuit is isolated and insulated Welgm 1.6 kg fa.d lbs)
PerfomMnge Warranty ,���'jj'gIIIIII'IIlgggl� High Power Output - h7r ' 3 _ ® . ^ from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This , 'i- [ - cooling Newel convection • No fans
1a akMr•2mrk ha, mewwxtd perbmwxe �� Co.grMMtl, pre-dvus r,Odds the LG NeON"2aak f 0 ••. I ''_� r " �• - Fnel reBmlrOnmenlel m8ng�wOutdoor�NEMAg
,Vig�RIBlSllmg7, further simplifies installation, enhances safety, and saves on labor and materials costs. _ -
wamway.]naemrldegmdatb,nrfaWnhrn n]fvyr has e.mdesgramsgi:llmulyanm•eesw@„t Connector type s M250.60.2LL•S22: MC4
m 0arsryt Ewn dte.:s yer,. dr «sguaanee 2alfp ef6drvy. tl,ptby mvNngit error e•r.:I•�:mdep,re. , --- a The En hese M250 Integrates seamless with the EngageCable, the Envo Communications M250-60-2U,-s25.Amph—IHd
,mewwa awl to Paco,. ftta,e, P a9 ly Y-
• Gateway"', and Enlighten', Enphase's monitoring and analysis software. - FEATURES - - -
li l, Apathetic Roof O O= -ding Durability - _ m - - - �CompedbAlly CompaOMe with 8D eiI PV modules I.
lG fiOM•2elefY hm MrndesignN •nmaesmedn tMmmn'reinlrtW frame desipt lGhrexrMN '0• '• '® ^• " "' °'• '� " , I I� • CammuniWllon A, - - Power line
di°'h"'� "'Bf art apPear.a ldatk tt e antwm ci'"P� NeON" x cud` r°'a"'°dd°'e a e r A w 1 PRODUCTIVE SIMPLE - RELIABLE 1 led routs The Dc circuit eem the requbemaMe for ungrouMeO Pv th - -
tlrpOdnmey4vmredrvahrdapApestywlm 2)era Adddree WNo0M•2SI exnermne N f. ntegre 8 erreYa
its mvden ae,lpt afAm md,gmr,000 Pa aedamm krd,Pm5a0p Pan _
I - NEC 890.35. Equipment ground U Pmvlded th the
- ! y-. - -. Optimizetl la higher -pourer • No GEC needed for mkroldverter - 4th enemlion product Enodac ion (G No
4 . 'B edditbnal GEC h ground b required. Ground fault protacdM (GFP) b
—�� n10d1d89 • - NO DC design Of string (:8lotdatbn -More th8n 1 motion hours 01 testing imogmled I t N kminverter.
•Better Performance on a Sunn Da Double -Sided Cell Structure p — '
IL NNN'•2Brd m.pnrrn,sbvaomsumydry, ��q��������p{�, lne,erof urasuad'n IG NeON"2@ad,wmma,ae9 y' 'MaxIM2a9 energy production required • - add m011pna of un195hIPped Monitoring •. r, - ENIgManM ger wd MyEnlighten monitonng options -
' tNr. m4swoAwatemperatwemdRdmry dlliBleflld mrxraaov,Naasder,o,¢de gveo-vn rtkrna - - •p i _-•f. 4- MiNmizee impact of shading, c. •- Easy tnatellation With Engage - .- Induslrylead'ug warranty, u0 to 25 �Complirmee UU741AEEElW FCC Pon 15 Class 8. C/N/CSA-C22.2 N0.0-M9�Fa•
VlIIWItll7 hm,der,sraf menmlee mN>nrbdmgeeeta ,..— duel. and debris Cifb yeera 0.4-04. and 107.1-01
.q xme•u Medduv,]Ipa ex S - . a. • n „ m.,. ewma,yr.•r,e. • t S " •Freyuenoy humus can W exte,ded beyohofnionb,el 11 required or me Wery-
' !r - � _ poMa.uxa Sd.on,x••tbe .- .. '•• '
-r ®LG
Ae•e p ra•dr 5 aeembAmdN .m..am }
e•s.•Pt•� b ��n r t -•ea a a • • d, a•Q..w.m.�a• •�..•ed ..,aP • h �„ ,m„me m•a,Na,a _w• • . ;• lei enphase• sp. To team mo a about Enphase Mlcroinverter technology, f enphase•' `
w•vao�rymemA,aw.nw.,wue:mmna,cR a,wen.•a,•m•ue raw w.�vew�.r elar.em.n¢uoe�rrwv,mv. w,u•,mta++r,+•waxwu» t O E N E R G Y - • 1, r C W VISIT 8nPh880.COm r. l i L� E N E R G Y
,m..px,wt,n.N,w.1,At1mw0a•finemr t,e+,ereex+Ww)•mtaetl.wC..ian Pe.�mawe,memnvcm,au. •a,v� .- ' t _ , -. .w. . • � -
- • . 1: - • �' • • OMIaGV�•Etrp{Nrtye„egwO.NenEvmA•O bmxb bebdavmehe
• , mptl•od lMOv,pe)eeAo dnv.- ,UtrCeOA Re, I.O
IF
f 1 ^' I _ ,. • „ '. J , f r •. � r • a � ' • ..• t t + • `• ,• , {`; e ; t 3 ' ~ , � • r- ,
,. A
.S y'
- t
-d i r. . � - - � _ r « e ... I - • 1 j 1 � r � , ' i t. tie; t
- ,. - °• - � tit. i •' r w - � - +„
a