Loading...
HomeMy WebLinkAboutB16-0715 000-000-000` -APPROVAL STAMP AND ADDITIONAL -NOTES FOR THE CITY OF: CHICO r•' SHEET'INDEX , = SYSTEM OVERVIEW PROJECT NOTES: w _ ' '. COVER `' (N) 15KW PV SYSTEM INSTALLED PLOT .PLAN: � � . ` _ - ' PV -I ,, ' '• ' �Y . .. • .. RESIDENTIAL MAIN SERVICE PANEL: 5.4KW PHOTOVOLTAIC LAYOUT: • • - ATTACHMENT LAYOUT &CALCULATIONS: PV -2 'tw ' ', (18)`LG LG300NIK-G4 _ r •,, -' . y' s ,, , , 2• ATTACHMENT. DETAILS_ . .. PV -2.1 ,� .. ,.. ELEVATION DETAILS: • PV -2.2 T (18)'ENPHASE M250-60-2LL-S22 ,' FIRE SIGNS/LABELS: r PV -3 .. ^ ` ,�,1 . t=: (COMMERCIAL'MAIN SERVICE PANEL: 9.6KW _ L SINGLE LINE DIAGRAM: _ PV -4 _ t , ' ".' - (32):LG300NIK-G4 LG ' SEPARATE PLACARD: ATTACHED ' •:,'. .:. MANUFACTURE SPEC. SHEETS: ATTACHED (32) ENPHASE-M250-60-2LL-S22_ - GENERAL NOTES r,`,:CUSTOMER INFORMATION • ALL WORK TO COMPLY WITH (2011 NEC) 2013 CALIFORNIA ELECTRIC-CODE1, ", '. ` ` ,ANTHONY. GENTILE L' _ ARTICLE 690,, 2013 CALIFORNIA BUILDING CODE. '" r ' ' µ 2270 NORTH ,LINDO AVENUE `: f . - - • CONDUCTORS EXPOSED TO,SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT . _ � PER.NEC 310.0(D) ',' +: A CHICO, CA 95973 r' ,. . • CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE:IN;WET ' LOCATIONS PER NEC 310.8(C) ' € ' r* . (56 2) 277-4016 • • WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT,` ;APN #047-080-074 WILL BE MAINTAINED IN ACCORDANCE WITH THE NEC 110.26' CONTRACTOR INFORMATION - • EXACT CONDUIT RUN LOCATIONS SUBJECT TO CHANGE. y '. ` • SMOKE ALARMS AND CO2 ALARMS TO BE INSTALLED _ ' i " s • -STRUCTURAL MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED s ` 'SOLAR SOURCE INC. AND VERIFIED AS NECESSARY FOR LAG BOLT PENETRATIONS BY CONTRACTOR. W 's ' ' • SEAL,CONNECTION POINTS WITH ROOF.GRADE F=}4;•. ,, s,` 4801- E,, ANAHEIM STREET r' '� f ! . - • - ROOF PENETRATIONS ARE SEALED WITH SCHNEE MOREHEAD 7108. SEALANT. - t LONG` BEACH, CA 90804 ` ` ` "• • PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY,WIRING _ ti .. •' TO CONDUIT WIRING. -.-: '.. r ' (562) 852-5626 ' t ` `' r '� • PV_POWER SOURCE, 600VDC, 240VAC, VISIBLE, LOCKABLE, NEMA 3R RAINPROOF, i" 30A AC DISCONNECT. SOLAR SOURCE INC. _ - k y •` PROVIDE GROUND ELECTRODE SYSTEM -FROM INVERTER TO EXISTING MAIN::.6 '` #925231 . , SERVICE GROUND ELECTRODE. - - - • - ,` '- . • • GROUND ELECTRODE CONDUCTOR FROM INVERTER TO GROUND ELECTRODE TO BE ^y-6 - • - MINIMUM PROTECTION OF BARE ARMOR SHEATED CABLE FOR ALL CONDUCTOR y SIZES. ` • ALL GROUND CONNECTED TO MAIN SERVICE GROUND IN MAIN SERVICE PANEL. X ' ' • INVERTER IS LISTED TO UL -1741 "UTILITY INTERACTIVE" s r r; • ALL CONDUCTORS SHALL BE 600V, 90C STANDARD COPPER. .. • • ALL CONDUCTORS IN CONDUIT SHALL BE THWN-2. r r • MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2% , BUTTE' `' Y • ALL CONDUCTORS SHALL BE IN CONDUIT'UNLESS OTHERWISE NOTED. APR 1 1 201 x .5 ' . ' VICINITY MAP SOLAR -sous •- D:EVELOPMEN•h • - � " �RESIDEWIAC:L COMMERCIAL SOLAR PROFESSIONALS SERVICES � 07/� •Q/6 REV. DESCRIPTION DATE _ T• 2270 N Lindo Ave :--.�--.•..--- A 'INITIAL DRAFT 3/17/2016 r• - 1 I C 'hv `• I D • • (E) OCCUPANCY GROUP: R -3F � { f 1' DATE: 4/8/16 SYSTEM OVERVIEW ' • (E) TYPE OF CONSTRUCTION. V—B -' , • (E) SPRINKLERS: NO ,�r* COVER DRAFTER: NM t SYSTEM OVERVIEW 634'-11"(N) 15KW PV SYSTEM INSTALLED RESIDENTIAL MAIN SERVICE PANEL: 5.4KW (18) LG LG300NIK-G4 (18) ENPHASE M250-60-2LL-S22 COMMERCIAL MAIN SERVICE PANEL: 9.6KW (32) LG LG300NIK-G4 (32) ENPHASE M250-60-2LL-S22 o• CUSTOMER INFORMATION °O s ANTHONY GENTILE I 2270 NORTH LINDO AVENUE �O CHICO, CA 95973 . F (562) 277-4016 APN #047-080-074 CONTRACTOR INFORMATION 0" SOLAR SOURCE INC. \eI�aae,4801 E ANAHEIM STREET 281'-5 LONG BEACH, CA 90804 230'-5" (562) 852-5626 Driveways SOLAR SOURCE INC. b [North Lindo Avenue] 46 #925231 lb DET I A_PVI. —I - X c, Ln 0� ��� N soLn •SOURC RESIMMIAL ✓ COMMERCIAL SOLAR PROFESSIONALS PLOT PLAN & INSTALL LOCATION SCALE:. ["=1.50' PV (50) LG LG300NIK-G4 SP 125A "PV DEDICATED" SUB PANEL E:] PV SOLAR MODULES -FLUSH MOUNTED REV. DESCRIPTION DATE OP INV -1 ® ® VENTS & OBSTRUCTIONS ® CHIMNEY A" INITIAL DRAFT 3/17/2016 MICRO (50) ENPHASE M250-60-2LL-S22 INV -2 ROOF ACCESS POINT: ROOF ACCESS POINT SHALL BE- LOCATED B , MSP INV -3 IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS C OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG D MSP -D - JB JUNCTION BOX POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE' -ACCESS E MSP -U PROPOSED PV CONDUIT RUN ABOVE ROOF POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. DATE: 4/8/16 PLOT PLAN PM i'- PROPOSED PV CONDUIT RUN THROUGH ATTIC AC PROPERTY LINES DRAFTER: NM P V — I INSTALL LOCATION SCALE: 1" = 30' PV OP I 1-1/4" Schedule 40 Through 1 Trench, Buried min: 18" Below 1 Grade, Approx. 80' Length 1 1 AC 1 100A Meter w/Bypass Blocks, 3-phase, 240V (50) LG LG300NIK-G4 MICRO (50) ENPHASE M250-60-2LL-S22 MSP MSP -D MSP -U PM AC 60A FUSED AC DISCONNECT W/60A FUSES SP 125A "PV DEDICATED" SUB PANEL INV -1 INV -2 INV -3 JB JUNCTION BOX PROPOSED PV CONDUIT RUN ABOVE ROOF i PROPOSED PV CONDUIT RUN THROUGH ATTIC -� PROPERTY LINES TEM SYSTEM OVERVIEW (N) 15KW PV SYSTEM INSTALLED RESIDENTIAL MAIN SERVICE PANEL: 5.4KW (18) LG LG300NIK-G4 (18) ENPHASE M250-60-2LL-S22 COMMERCIAL MAIN SERVICE PANEL: 9.6KW ;(32) LG LG300NIK-G4 (32) ENPHASE M250-60-2LL-S22 CUSTOMER INFORMATION ANTHONY GENTILE 2270 NORTH LINDO AVENUE CHICO, CA 95973 (562) 277-4016 APN #047-080-074 CONTRACTOR INFORMATION SOLAR SOURCE INC. 4801 E ANAHEIM STREET LONG BEACH, CA 90804 (562) 852-5626 SOLAR SOURCE INC. C46 #925231 X SOLAR SOURCE RESIDENTIAL / COMMERCIAL SOLAR PROFESSIONALS 0 PV SOLAR MODULES - FLUSH MOUNTED REV. DESCRIPTION DATE ® ® VENTS & OBSTRUCTIONS ® CHIMNEY A INITIAL DRAFT 3/17/2016 ROOF ACCESS POINT: ROOF ACCESS POINT SHALL BE LOCATED B IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS C OVER OPENINGS SUCH AS WINDOWS OR DOORS,AND LOCATED AT STRONG D POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS E POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. DATE: 4/8/16 INSTALL LOCATION Pv—DRAFTER: NM I . I ' F w PV MODULES FIRE CLEARANCE AREA ® ® OBSTRUCTIONS is ROOF PENETRATION POINTS + fi -- RAFTERS --- RAILS PROPERTY LINES ,^:' SYSTEM OVERVIEW !., �(N) 15KW P.V SYSTEM INSTALLED • E !' RESIDENTIAL'MAIN SERVICE PANEL: 5.4KW. (18) LG LG300NIK-G4 ` { �' ti - _ +.,• �< ''_ . +` '?.i' . .rte (18) ENPHASE,M250-60-2LL-S22 - . r .r "• ,.� 4 `COMMERCIAL MAIN,SERVICE-PANEL: 9.6KW '(32) LG LG300NIK-G4 (32)`ENPHASE M250-60-2LL-S22 d. f. r. - s�. • _' f �:.: .• �. CUSTOMER, INFORMATION r + e ANTHONY GENTILE .. i j } 2270 (NORTH UNDO AVENUE _ � .- - , � _ PFS _ ' � , ..� • ' , s �• �; � , *^�'< ,� r,, '� .��. - K • ,: F . ' 1p CHICO,,CA 95973 (562)-277-4016 �' (� 3�`�,, c�Q +• �' APN #047-080-074 ,CONTRACTOR INFORMATION — S - 4�{ .!: ` f '• /' , P` .- ' R1 SOLAR SOURCE INC. - " f - - ♦ . , +�Vr. - �/ - i .., - . - !. �- a ^w, :� 4801.k.E-'ANAHEIM STREET 'LONG BEACH; CA 90804, �; ' (562), 852-5626 4': SOLAR SOURCE _INC.'., a� , _ 3 :r:: Y♦. = , r . F : �:, C46 #925231 A. \/�'�?cel 1 - � •y � *f _ ., .n _ "� ; • ^, r . SOLAR SOURCE' =N R2 RESIDENTIAL / COMMERCIAL.SOLA; ?ROFESSLON/�LS R3 ATTACHMENT DETAIL i TAG ROOF INFORMATION „` REV. DESCRIPTION' DATE „._ ,' „ * �" RI 24 MODULES,.COMP: SHINGLE ROOF, 145° AZIMUTH�;IS° TILT,, MOUNTED BILL OF MATERIALS rj�. A INITIAL DRAFT 3/17/2016 SCALE: 1/16 - I —0 . �. ;.� • R2 20 MODULES, COMP. SHINGLE ROOF, 120° AZIMUTH,`15° TILT, FLUSH MOUNTED. N0. PRODUCT DESCIPTION QTY. - B MOUNTING INFORMATION R3 6 MODULES, COMP.'SHINGLE ROOF, 2120 AZIMUTH;',IS°-TILT„FLUSH MOUNTED' :' I LG LG300NIK-G4 ♦ 50 C MOUNTING SYSTEM MANUFACTURER: EVEREST 164 RAILS WITH QUICK MOUNT Q -RACK „ PV EQUIPMENT INFORMATION_ ? 2 ENPHASE M250-60-2LL-S22 50 D TOTAL WEIGHT OF MODULES & RACKING (LBS): 2052 { MODULE WEIGHT: 37.48 LBS 3 EVEREST 164” RAILS 25 E " NUMBER OF ATTACHMENT POINTS: 74 -,. MODULES SQ.FT..(64.57" x 39.37" X 1.57") 17.65 4- QUICK MOUNT Q -RACK 74 a ATTACHMENT LAYOUT , WEIGHT (LBS) /ATTACHMENT POINT 27.73 �' • ARRAY SQ.FT. `= .882.68 5 EVEREST END CLAMPS " ,` '32 DATE: 4/8/16 TOTAL SURFACE AREA OF PV•MODULES (SQ.FT.): 882.68'x'• RACKING WEIGHT:', `y . .3.63.56 LBS/MODULES 6 EVEREST MID CLAMPS 80 PV -2 DISTRIBUTED WEIGHT OF PV MODULE.ON ROOF (LBS/SQ.FT.): 2 32 ROOF LOAD (MODULE WEIGHT / MODULE AREA): 2.12 LBS/SQ.FT. - DRAFTER' NM CONDUIT DETAILS ATTACHMENT DETAILS SYSTEM OVERVIEW (N) 15KW PV SYSTEM INSTALLED T -BOLT END CLAMP RESIDENTIAL MAIN SERVICE PANEL: 5.4KW (18) LG LG300NIK-G4 RAIN TIGHT, STEEL EMT CONNECTOR. STRUT STRAP EVEREST SUPPORT RAIL (18) ENPHASE M250-60-2LL-S22 _ BELL BOX PV MODULE MIN. 3.5" ABOVE ROOF COMMERCIAL MAIN SERVICE PANEL: 9.6KW STRAIN RELIEF (32) LG LG300NIK-G4 DC (PV) OR AC (MICROINVERTER) (32) ENPHASE M250-60-2LL-S22 CABLE L -Fool CUSTOMER INFORMATION MODULE 6" STANDOFF / ANTHONY GENTILE _- COMP. SHINGLE ROOF �j�j 2270 NORTH LINDO AVENUE / - CHICO, CA 95973 O.C. i / (562) 277-4016 RAFTER „Rafter / � 2" X 6 APN #047-080-074 CONTRACTOR INFORMATION 2" X 6" BLOCK // EMT CONDUIT ABOVE ROOF MAX HEIGHT: 3,V" SOLAR SOURCE INC. MIN HEIGHT: %" 4801 E ANAHEIM STREET (2) 5/16"X3" LAG BOLT (MIN. 2.5" EMBEDDED) LONG BEACH, CA 90804 (562) 852-5626 SOLAR SOURCE INC. GROUNDING DETAIL - C46 25231 MODULE TO MODULE MODULE TO RAILS RAILS TO RAILS X SELF TAPING SCREW SOLAR SOURCE. PV MODULE RESIDENTIAL / COMMERCIAL SOLAR PROFESSIONALS USE WEEBL-6.7 ASSEMBLY PER MID -CLAMP RAIL TO CONNECT SYSTEM TO EQUIPMENT GROUND CONDUCTOR. REV. DESCRIPTION DATE WEEB-PMC GROUND BONDING JUMPER RACKING A INITIAL DRAFT 3/17/2016 SLIDING NUT B NTS REMOVAL OF ONE PIECE OF EQUIPMENT SHALL C NOT DISCONNECT THE NDING D MOUNTING RAIL BETWEEN ANY OTOHER PIE CE BETWEEN E DATE: 4/8/16 ATTACHMENT DETAILS PV -2.1 DRAFTER:: NM PARTIAL FRAMING DETAIL MODULE HEIGHT DETAIL SYSTEM OVERVIEW (N)•15KW PV SYSTEM INSTALLED RESIDENTIAL MAIN SERVICE PANEL: 5.4KW (18) LG LG300NIK-G4 (18) ENPHASE M250-60-2LL-S22 COMMERCIAL MAIN SERVICE PANEL: 9.6KW Beam, Truss Bracing, or Bearing Wall - (32) LG LG300NIK-G4 (32) ENPHASE M250-60-2LL-S22 CUSTOMER INFORMATION ANTHONY GENTILE CV 2270 NORTH UNDO AVENUE LU w CHICO, CA 95973 0 0 (562) 277-4016 O APN #047-080-074 LU o C3 CONTRACTOR INFORMATION w Q SOLAR SOURCE INC. 4801E ANAHEIM STREET LONG BEACH, CA 90804 (562) 852-5626 �-2° X 6° RAFTERS, 24° 0. C., MAX SPAN: 6----;."` :SOLAR SOURCE INC. C46#925231 X ELEVATION VIEW COMMERCIAL ELEVATION VIEW = RESIDENTIAL TO PV ARRAY WITH MICROINVERTERTO M PV ARRAY WITH MICROINVERTER SOLAR SOURCE, RESIDENTIAL / COMMERCIAL SOLAR PROFESSIONALS M . O REV. DESCRIPTION DATE A C S P S P S A INITIAL DRAFT 3/17/2016 B P TO PV ARRAY TO PV ARRAY C THROUGH TRENCH GRADE GRADE THROUGH TRENCH D E 18' MIN. L----------J DATE: 4/8/16 ELEVATION DETAILS GRADE Pv-2.2-j DRAFTER: NM { SYSTEM OVERVIEW (N) 15KW PV SYSTEM INSTALLED RESIDENTIAL MAIN SERVICE PANEL: 5.4KW (18) LG LG300NIK-G4 (18) ENPHASE M250-60-2LL-S22 COMMERCIAL MAIN SERVICE PANEL: 9.6KW (32) LG LG300NIK-G4 . (32) ENPHASE M250-60-2LL-S22 Collector {� M CUSTOMER INFORMATION Panel / ANTHONY GENTILE Solar 2270NORTHUNDO AVENUE ■ Oa A + _ CHICo, CA 95973. J B Load /,1 - M�7P (562) 277-4016 Center C APN #047-080-074 CONTRACTOR INFORMATION AC PV COMBINER SOLAR SOURCE INC. PHOTOVOLTAIC AC DISCONNECT AC DISCONNECT MAIN SERVICE PANEL MAIN SERVICE DISCONNEC 4801 E ANAHEIM STREET 04A 908 MAXIMUM Ac OPERATING CURRENT: 2$.25A PHOTOVOLTAIC AC DISCONNECT WARNING MAIN PV SYSTEM, LONG BEACH, C , MAXIMUM AC OPERATING VOLTAGE: 240V MAXIMUM AC OPERATING CURRENT: P8•25A ELECTRICAL SHOCK HAZARD DISCONNECT -*' DO NOT TOUCH TERMINALS. (562) 852-5626 Per NEC 690.54 MAXIMUM AC OPERATING VOLTAGE: 240V TERMINALS ON BOTH THE LINE AND PER NEC 6 NEC6 0.15 IFC NEC690..1, 11 LOAD SIDE MAY BE ENERGIZED IFC 605 11.14, EC 690.15 &C 690.53 ® WARNING ® Per NEC 690.54 IN THE OPEN POSITION CAUTION: SOLAR SOURCE INC. ELECTRICAL SHOCK HAZARD PHOTOVOLTAIC PER NEC 690.17(4) SOLAR ELECTRIC SYSTEM CONNECTED 046 #925231 DO NOT TOUCH TERMINALS. PER NEC 690.14(C)(2), IFC 605.11.1, , TERMINALS ON BOTH THE LINE AND AC DISCONNECT WARNING. IFC 605.14.1.4, NEC 690.15 & NEC 690.53 LOAD SIDE MAY BE ENERGIZED Array (Modules and Microinverter) IN THE OPEN POSITION TURN OFF PHOTOVOLTAIC SOLAR DISCONNECT PER NEC 690.17(4) Per NEC 690 14(0)(2) & 696.15 AC DISCONNECT PRIOR TO X WARNING: PHOTOVOLTAIC WORKING INSIDE PANEL PER NEC 605.11.1 POWER SOURCE PER NEC 110.27(C) & OSHA 1910.145(F)(7) PER NEC 690.31(E)(3) & IF 605.11.1.2 _ WARNING SOLAR CIRCUITS ONLY. - NO OTHER LOADS - ALLOWED. ISOLA .' SOURCE RESIDENTIAL / CONIMERCIAL SOLAR PROFESSIONALS When It's A Microlnverter System PV SYSTEM IS SUPPLIED WITH MICROINVERTERS LOCATED AT ROOF MOUNTED PANELS REV. DESCRIPTION DATE A INITIAL DRAFT 3/17/2016 FORMAT: (1) WHITE LETTERING ON A RED BACKGROUND. B (2) MINIMUM % INCHES LETTER HEIGHT. C (3) ALL LETTERS SHALL BE CAPITALIZED D (4) ARIAL OR SIMILAR FONT, NON -BOLD. " MATERIAL: E REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE t DATE: 4/8/I6 NEC FIRE LABELS FOR THE ENVIRONMENT (USE UL -969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS Pv_3 DRAFTER: NM PV MODULE INFORMATION (32) LG LG300NIK=G4 POWER AT STC: 30OW POWER AT.PTC: 273.4W - V -OC (OPEN -CIRCUIT, VOLTAGE) .' 39.7V V -MP ,(MAX -POWER. VOLTAGE).: 32.5V I -SC (SHORT-CIRCUIT CURRENT) : 9.7A I -MP (MAX -POWER: CURRENT) : 9.26A MNFR V -OC TEMP'COEFFICIENT:-0.28%/°C ` (1-sC x 1.25 x 1.25) : 15.16A N PM AC AMBIENT TEMPERATUREINFORMATION AMBIENT TEMP. 40° C 'AMBIENT TEMP. ABOVE ROOF:' 62° C EXTREME MIN TEMP: : -4° C. VOLTAGE DROP INFORMATION TOTAL DC VOLTAGE DROP % :.0 .TOTAL.AC VOLTAGE DROP % :.0..4$ TOTAL SYSTEM VOLTAGE DROP % : 0:48 . SYSTEM OVERVIEW (N) 15KW PV SYSTEM. INSTALLED RESIDENTIAL MAIN SERVICE PANEL: 5.4KW (18) LG LG300NIK-G4 ' (18) ENPHASE M250=60-2LL-S22- COMMERCIAL MAIN .SERVICE PANEL: 9.6KW (32) LG LG300NIK-G4 (32) ENPHASE M250-60-2LL-S22 CUSTOMER- INFORMATION : 'ANTHONY GENTILE 2270 NORTH LINDO AVENUE CHICO, CA 059.73. (562) 27774016: : APN #047-080-074 AC:I. (2) TRUNK CABLE W/INTEGRATED GROUND (2) #6 AWG BARE COPPER GROUND IN FREE AIR To .J -BOX: AMPERAGE 13.2 PER NEC 310.15(B)OXA) :.l PER NEC 310.15(B)(2)(A) 0.65 (13.2) / 0 x 0.65)-:, 20.3` DISTANCE IN FEET ': 5: VOLTAGE DROP % 0.12 J QAC.3 L1 3 N L.1 L1 L1 ' �_ .' ®_ L1 L1 . 2oA iooA 2 N E�G N3::. Lu G -E,G G - - / Ground Rod Lu G . G G L1 L1 L1 AC:I. (2) TRUNK CABLE W/INTEGRATED GROUND (2) #6 AWG BARE COPPER GROUND IN FREE AIR To .J -BOX: AMPERAGE 13.2 PER NEC 310.15(B)OXA) :.l PER NEC 310.15(B)(2)(A) 0.65 (13.2) / 0 x 0.65)-:, 20.3` DISTANCE IN FEET ': 5: VOLTAGE DROP % 0.12 20A (E) GROUNDING \ \ .125A SUB -PANEL ELECTRODE N W/ 100A .BREAKER G J=BOX �.' NEMA: 3R: AC. -2, (5).4I0'AWG. THWN-2 (1) #6 AWG THWN-2 GROUND 3/4" EMT.CONDUIT. AMPERAGE 13.2' PER NEC 310.15(B)(3)(A) :.0:8 PER NEC 310.15(B)(2)(A) : 0.91 (13.2) / (0.8 •x. 0.91) 18..13 DISTANCE -IN FEET : 15 VOLTAGE DROP % : 0.22 At. 3 (3).#10 AWG THWN-2 (1) #6 AWG THWN-2 GROUND' 3/4" EMT CONDUIT. AMPERAGE 28.25' PER NEC 310.15(B)(3)(A) ': I PER NEC 310:15(13)(2)(A) < 0.91 .(28:25) / (1 x'0'.91) 31.04 DISTANCE IN FEET:: 5: ' VOLTAGE DROP % 0.15 J 20A (E) GROUNDING \ \ .125A SUB -PANEL ELECTRODE N W/ 100A .BREAKER G J=BOX �.' NEMA: 3R: AC. -2, (5).4I0'AWG. THWN-2 (1) #6 AWG THWN-2 GROUND 3/4" EMT.CONDUIT. AMPERAGE 13.2' PER NEC 310.15(B)(3)(A) :.0:8 PER NEC 310.15(B)(2)(A) : 0.91 (13.2) / (0.8 •x. 0.91) 18..13 DISTANCE -IN FEET : 15 VOLTAGE DROP % : 0.22 At. 3 (3).#10 AWG THWN-2 (1) #6 AWG THWN-2 GROUND' 3/4" EMT CONDUIT. AMPERAGE 28.25' PER NEC 310.15(B)(3)(A) ': I PER NEC 310:15(13)(2)(A) < 0.91 .(28:25) / (1 x'0'.91) 31.04 DISTANCE IN FEET:: 5: ' VOLTAGE DROP % 0.15 PV MODULE INFORMATION (32) LG LG300NIK-G4 POWER AT STC: 30OW POWER AT PTC: 273.4W V -OC (OPEN -CIRCUIT VOLTAGE) : 39.7V V -MP (MAX -POWER VOLTAGE) : 32.5V I -SC (SHORT-CIRCUIT CURRENT) : 9.7A I -MP (MAX -POWER CURRENT) : 9.26A MNFR V -OC TEMP COEFFICIENT: -0.28%/°C 0-sc x 1.25 x 1.25) : 15.16A 125A SUB -PANEL LUG ONLY (N) PV BREAKER : 20A (N) PV BREAKER : 20A TOTAL OUT -PUT : 26.4A (DI.- zz U 37 Q CL > cs CL U-1 cD i__ z �w Q37 > d CL W AC.I - (2) TRUNK CABLE W/INTEGRATED GROUND (2) #6 AWG BARE COPPER GROUND IN FREE AIR TO J -BOX AMPERAGE 13.2 PER NEC 310.15(8)(3)(A) : I PER NEC 310.15(B)(2)(A) : 0.65 03.2) / (I x 0.65) : 20.3 DISTANCE IN FEET 5 VOLTAGE DROP % : 0.12 STRING INFORMATION TAG DETAILS A 16 MoD's, 145° a 1200 Az, 151 TILT B 16 MODS, 120° & 2121 Az, 15° TILT (32) ENPHASE M250-60-2LL-S22 (240V) TAG (LOA X CITY. X 1.25): BREAKER SIZE A (I.OA x 16 x 1.25): 20A (20A) B 0.0A x 16 x 1.25): 20A (20A) C D E F G H AC.2 AC. I _ _ . - AC. 2 (5) #10 AWG THWN-2 (1) #6 AWG THWN-2 GROUND 3/4" EMT CONDUIT AMPERAGE 13.2 PER NEC 310.15(B)(3)(A) : 0.8 PER NEC 310.15(B)(2)(A) : 0.91 03.2)/(0.8x0.91): 18.13 DISTANCE IN FEET 15 VOLTAGE DROP % : 0.22 AC.3 (3) #10 AWG THWN-2 (1) #6 AWG THWN-2 GROUND 3/4" EMT CONDUIT AMPERAGE: 28.25 PER NEC 310.15(B)(3)(A) : I PER NEC 310.15(B)(2)(A) : 0.91 (28.25) / 0 x 0.91) : 31.04 DISTANCE IN FEET 5 VOLTAGE DROP % : 0.15 PM - AC 30A KNIFE -BLADE AC DISCONNECT AMBIENT TEMPERATURE INFORMATION AMBIENT TEMP. : 40° C AMBIENT TEMP. ABOVE ROOF: 62° C EXTREME MIN TEMP. : -4° C VOLTAGE DROP INFORMATION' TOTAL DC VOLTAGE DROP % : 0 TOTAL AC VOLTAGE DROP % : 0.48 TOTAL SYSTEM VOLTAGE DROP % :'0.48 To Utility Grid Overhead Service Drop SYSTEM OVERVIEW (N) 15KW PV SYSTEM INSTALLED RESIDENTIAL MAIN SERVICE PANEL: 5.4KW (18) LG LG300NIK-G4 (18) ENPHASE M250-60-2LL-S22 COMMERCIAL MAIN SERVICE PANEL: 9.6KW (32) LG LG300NIK-G4 (32) ENPHASE M250-60-2LL-S22 CUSTOMER INFORMATION ANTHONY GENTILE 2270 NORTH .UNDO AVENUE -CHICO, CA 95973 (562) 277-4016 APN #047-080-074 CONTRACTOR INFORMATION SOLAR SOURCE INC. 4801 E ANAHEIM STREET LONG BEACH, CA 90804 (562) 852-5626 SOLAR SOURCE INC. C46#925231 Ground Rod X T (E) GROUNDING ELECTRODE _ SOLAR SOURCE' RESIDENTIAL / COMMEitC1AL SOLA;t ?;t0FESSIONALS REV. DESCRIPTION DATE A INITIAL DRAFT 3/17/2016 B Ci D E DATE: 4/8/16 9.6KW THREE PHASE SLD DRAFTER: NM PV-40*1., S PLACARD CAUTION POWER TO THE BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AT SHOWN SERVICE POINT PV DISCONNECT UTILITY METERING - e� � • � . }_ ` 4, .. i n, nor . , - 4 .. r �'� ft - j.. .�-, • -J - + r,- - - .- �.��' •• ] 'r d � r. }� t .y ' °��-_ � ,a" s .• - - _ r W-_., d. t• �a,� 1 .Y - .. r -' r / !; >1�F '• +_ � � -, d ( _ 9' •"� � � t`.- sly r, `L!• t_ ` * Y .'. (, � !�• ,,,. F .. y " • 47 -:. + to •�{ ,� r - . _,, • �. •I n ^ '3 . +. 4: � .. ,' a' a ^, t' a~ - r Fa• , - . FF - (,, _s ,•j, r `•4. '1 a `� Fs -T .. J . • •c)', •z' ,R• fly kn Air - . ' � �L''�� _ kr,, ,.a _ s /. 7 •- ,tai ./ _. • •.. T r'• -4 \- � Ey1 , • r f.. ' - •.' , Irk • t .. ' d . - • 7 Y - / 4 I ^• • • �. a ' • 'w •', - .•,.e •' . •,�+ .•. t r r'•. y •' - - •• - },r` .. � •..♦ t , ,•y s- �� - r '`.! • • •I" � A yZ.♦ A a �• ;. S LG NeON'zemcka ® LG • • • • t - • - �.. i..' $ •► 2 • EnMesD M250 Micrainverter // DATA • r_. Life, • ` .' y A n'••i...i - Mluhental P,,opintln - .v' �• Electtiod Properties (STC •) - t Enphass, orolnvertere 1•-e r• '�. ] INPUT DATA (DC) - M260.80.2LL-S22, M260 -BD -2L4825 a .. Better y " .• _• ' • mw ' - • �li•Commen__ Input Powe (STC) � 2101310 W • •i us w.m -m uw wrca.rvwv> ]zs L% _ v - Mezbn , OC voO Be ti' 48v _ �� �°�--—rm.•t�e, B�e �Enphas&M250' r Peekpowerr9ckhgveltega, 27V 39V I54)5.156.)smm/41me Opm CYnuhtyh•W abt) l9) 4• a ' O tin Y IBV 48V - •'wt �' •V rt` .Mw,mv lx(rAdl Wxe &rtav10 Sbttkdt tw.•nlhv) 9th 1' ., . - • • d , y ' . Operating _ _ � ♦ . .. ebwebm (l•WN) ifia0. re0D. •0mm ap •{ MINMex alert vallage 22 V/48V • "� �� - 6a5).39J).1.51YN ae•rrk,e T•,nrw•vtSl-a0-•90 - ♦. _ _ ' nantaW sonow/tx5od0 - e�9raw vvlrr.M. taco s•� - .I � 1 - Max DC airort circuit curtanl � 15A Mla•a - LOOWI,I)I,✓• Seln M•RnxiaW m .; } - i " . . - - . w•ya I)Ozgs10/])aezl.Iw ltd,mx•pp o -•l • a T. yX7-N'. OUTPUT DATA IAC) 0208 VAC .0200 VAC�,a,erac.v.a •..renm.wra.. ..s_ \`r. . ` _250wz50®e)•1 391—oodr ""',"�ii4,"'`+•""`.A, .- • i. 1' ,. c Rated (continuous) output power 240W _ .. 240W y, t•va'h>am -000---l— - L r t * ♦ -: s NOMnaI olnpul wrreni 1.15 A U rma M nominal curelbM1.0 A (A rma at nominal c umllor0� 4 . m - = Hp,TmvNmml,.rpemfAtn - t t - _ � • „w„�,N„v,,,, _ ElecwolPropataea(NDrn) • „.. .> NominelwilaeeAenBe - 209v/1e322ev zdov/2n.2edv . tbadsTv mow \+.} +ti �, - 6. �. Nominal Irequancynenge _ 80.0/57-61 Hz _ _ _ Sao 157-61 Hz Certificatio and F ¢' gwuevrleNmry gCGIxIS�E[4tlm-I/] YW_,HIp.�M,gp) ) _xvJ e4.lri �' �? ;h3 Extended frequency range'- ' 57-82.5 Hz R. 57-82.5 H. t e - gtsma(Nma8reR7 rsPu..m,roAol ' ]JB ,. V • , Power factor LGNON'2 e(u�k tic e,]e, (,n scege d o l �am_ar • Y n a P�) ]4a i Maximum unite Par 20 A branch circuit 24 (three Phase) ; ! Ifi (single phase) Ne , rie9001 <w.•,a ll.q ^ ]al - _ 4 LLIra] rt...vurve., n.w•nree. e.. •......• ..r. • • , ..yy�s - k ., , Maximum output fault Conant 850 mA rtre for ecycles 850 mA rm9for8ryel ' rend. ra.wa•.x. tusA) r,vxea,m» - 1 r - 1 to i j) - a� ::..t • • EFFICIENCY e 7"r' �. �.'�- ra.wnA,h(N.uNAw) cwctuc/amn)w) •.Dimensions (mnfin)•' { .' .� i''' it 1 '�,) 1, .-. cEcweigmedefnaene>• ses% _ _ i . r , .. Ulls ne v modu4. ly WON- 2 911 adopts Cd. 1 - Prm,n w.n•n' I xwa, O - • _ ` � 4j[:. , � -. Peak lmarder e8klanuy * 96.5% _ tedv%WM Cello tedtmlopy radazas 3bushvs with Mv,a,vasv,ov' ..y �ug u•..�rurtar,�.0 - - F'a a • 1. •^iO`�'�t •n,.,� w • , ��'rrr---}������ i^, Sleue MPPr flkleney (weighted, reference EN50530) 89.4%y - uity USNe memrrcepolNtandmtoinc v / ® '_ ~ r • _ ax _ 60 tie ll LL NeON• 2 Black demonstrates Gl elfvms m In ma e D E C E ®' Tempe aturo Characteristics ectedstlo _ f{��1 1 Nigh time AN CAL —.ptin 65 mW max customees values beyaM efficiency. It featums enhanrn0 `, ` hoer e4z]< 3-1— 13 •• - 'MECHANICAL DATA - nucxdu,ability, performance under mal emdronment, '°��•"'�gNp -0JB 411 a..,, • • ' - andaesthetkdeslgnsuitable for roafz . e4. n, amlyc `� '^` •A ••i • �blem temperelureronge -d0°C to •85•C • - r r • - - - a.— - - - r' �I .. -_-- - ^. The Enphase• M250 Microinverter delivers Increased energy harvest and reduces design and - Dimensions (wxHxD) - _ - 171 mm x 173 mm x 30 mm twithum mounting breckeQ - Characteristic curves ':. installation complexity with its all -AC approach. With the M250, the DC circuit is isolated and insulated Welgm 1.6 kg fa.d lbs) PerfomMnge Warranty ,���'jj'gIIIIII'IIlgggl� High Power Output - h7r ' 3 _ ® . ^ from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This , 'i- [ - cooling Newel convection • No fans 1a akMr•2mrk ha, mewwxtd perbmwxe �� Co.grMMtl, pre-dvus r,Odds the LG NeON"2aak f 0 ••. I ''_� r " �• - Fnel reBmlrOnmenlel m8ng�wOutdoor�NEMAg ,Vig�RIBlSllmg7, further simplifies installation, enhances safety, and saves on labor and materials costs. _ - wamway.]naemrldegmdatb,nrfaWnhrn n]fvyr has e.mdesgramsgi:llmulyanm•eesw@„t Connector type s M250.60.2LL•S22: MC4 m 0arsryt Ewn dte.:s yer,. dr «sguaanee 2alfp ef6drvy. tl,ptby mvNngit error e•r.:I•�:mdep,re. , --- a The En hese M250 Integrates seamless with the EngageCable, the Envo Communications M250-60-2U,-s25.Amph—IHd ,mewwa awl to Paco,. ftta,e, P a9 ly Y- • Gateway"', and Enlighten', Enphase's monitoring and analysis software. - FEATURES - - - li l, Apathetic Roof O O= -ding Durability - _ m - - - �CompedbAlly CompaOMe with 8D eiI PV modules I. lG fiOM•2elefY hm MrndesignN •nmaesmedn tMmmn'reinlrtW frame desipt lGhrexrMN '0• '• '® ^• " "' °'• '� " , I I� • CammuniWllon A, - - Power line di°'h"'� "'Bf art apPear.a ldatk tt e antwm ci'"P� NeON" x cud` r°'a"'°dd°'e a e r A w 1 PRODUCTIVE SIMPLE - RELIABLE 1 led routs The Dc circuit eem the requbemaMe for ungrouMeO Pv th - - tlrpOdnmey4vmredrvahrdapApestywlm 2)era Adddree WNo0M•2SI exnermne N f. ntegre 8 erreYa its mvden ae,lpt afAm md,gmr,000 Pa aedamm krd,Pm5a0p Pan _ I - NEC 890.35. Equipment ground U Pmvlded th the - ! y-. - -. Optimizetl la higher -pourer • No GEC needed for mkroldverter - 4th enemlion product Enodac ion (G No 4 . 'B edditbnal GEC h ground b required. Ground fault protacdM (GFP) b —�� n10d1d89 • - NO DC design Of string (:8lotdatbn -More th8n 1 motion hours 01 testing imogmled I t N kminverter. •Better Performance on a Sunn Da Double -Sided Cell Structure p — ' IL NNN'•2Brd m.pnrrn,sbvaomsumydry, ��q��������p{�, lne,erof urasuad'n IG NeON"2@ad,wmma,ae9 y' 'MaxIM2a9 energy production required • - add m011pna of un195hIPped Monitoring •. r, - ENIgManM ger wd MyEnlighten monitonng options - ' tNr. m4swoAwatemperatwemdRdmry dlliBleflld mrxraaov,Naasder,o,¢de gveo-vn rtkrna - - •p i _-•f. 4- MiNmizee impact of shading, c. •- Easy tnatellation With Engage - .- Induslrylead'ug warranty, u0 to 25 �Complirmee UU741AEEElW FCC Pon 15 Class 8. C/N/CSA-C22.2 N0.0-M9�Fa• VlIIWItll7 hm,der,sraf menmlee mN>nrbdmgeeeta ,..— duel. and debris Cifb yeera 0.4-04. and 107.1-01 .q xme•u Medduv,]Ipa ex S - . a. • n „ m.,. ewma,yr.•r,e. • t S " •Freyuenoy humus can W exte,ded beyohofnionb,el 11 required or me Wery- ' !r - � _ poMa.uxa Sd.on,x••tbe .- .. '•• ' -r ®LG Ae•e p ra•dr 5 aeembAmdN .m..am } e•s.•Pt•� b ��n r t -•ea a a • • d, a•Q..w.m.�a• •�..•ed ..,aP • h �„ ,m„me m•a,Na,a _w• • . ;• lei enphase• sp. To team mo a about Enphase Mlcroinverter technology, f enphase•' ` w•vao�rymemA,aw.nw.,wue:mmna,cR a,wen.•a,•m•ue raw w.�vew�.r elar.em.n¢uoe�rrwv,mv. w,u•,mta++r,+•waxwu» t O E N E R G Y - • 1, r C W VISIT 8nPh880.COm r. l i L� E N E R G Y ,m..px,wt,n.N,w.1,At1mw0a•finemr t,e+,ereex+Ww)•mtaetl.wC..ian Pe.�mawe,memnvcm,au. •a,v� .- ' t _ , -. .w. . • � - - • . 1: - • �' • • OMIaGV�•Etrp{Nrtye„egwO.NenEvmA•O bmxb bebdavmehe • , mptl•od lMOv,pe)eeAo dnv.- ,UtrCeOA Re, I.O IF f 1 ^' I _ ,. • „ '. J , f r •. � r • a � ' • ..• t t + • `• ,• , {`; e ; t 3 ' ~ , � • r- , ,. A .S y' - t -d i r. . � - - � _ r « e ... I - • 1 j 1 � r � , ' i t. tie; t - ,. - °• - � tit. i •' r w - � - +„ a